WorldWideScience

Sample records for tire pressure monitoring

  1. Preventing Tire Blowout Accidents: A Perspective on Factors Affecting Drivers’ Intention to Adopt Tire Pressure Monitoring System

    Directory of Open Access Journals (Sweden)

    Kai-Ying Chen

    2018-04-01

    Full Text Available The aim of this study is to explore whether risk perception or anticipated regret is responsible for intensifying the participants’ intention to adopt a tire pressure monitoring system (TPMS to prevent a tire-related accident, and whether the optimism bias has a moderator effect between risk perception/anticipated regret and intention. With 274 valid questionnaires and PLS-SEM (partial least squares structural equation modeling analysis, the results indicate a significant positive relationship between risk perception and intention to adopt TPMS, but not between anticipated regret and intention. The moderator effect of optimism bias on risk perception and anticipated regret is not found in the model. The findings will prove useful for public service advertising campaigns by providing a basis for an understanding of the role of cognitive and emotional factors in tire-blowout accident prevention, thereby increasing the motivation for drivers in Taiwan to take advantage of the protection afforded them by using TPMS.

  2. Measurement of Vehicle-Bridge-Interaction force using dynamic tire pressure monitoring

    Science.gov (United States)

    Chen, Zhao; Xie, Zhipeng; Zhang, Jian

    2018-05-01

    The Vehicle-Bridge-Interaction (VBI) force, i.e., the normal contact force of a tire, is a key component in the VBI mechanism. The VBI force measurement can facilitate experimental studies of the VBI as well as input-output bridge structural identification. This paper introduces an innovative method for calculating the interaction force by using dynamic tire pressure monitoring. The core idea of the proposed method combines the ideal gas law and a basic force model to build a relationship between the tire pressure and the VBI force. Then, unknown model parameters are identified by the Extended Kalman Filter using calibration data. A signal filter based on the wavelet analysis is applied to preprocess the effect that the tire rotation has on the pressure data. Two laboratory tests were conducted to check the proposed method's validity. The effects of different road irregularities, loads and forward velocities were studied. Under the current experiment setting, the proposed method was robust to different road irregularities, and the increase in load and velocity benefited the performance of the proposed method. A high-speed test further supported the use of this method in rapid bridge tests. Limitations of the derived theories and experiment were also discussed.

  3. 49 CFR 571.138 - Standard No. 138; Tire pressure monitoring systems.

    Science.gov (United States)

    2010-10-01

    ... following statement in English: Each tire, including the spare (if provided), should be checked monthly when... level to trigger illumination of the TPMS low tire pressure telltale. [The following paragraph is.... If necessary, drive the vehicle until the telltale has extinguished. (o) The test may be repeated...

  4. Design optimization under uncertainty and speed variability for a piezoelectric energy harvester powering a tire pressure monitoring sensor

    Science.gov (United States)

    Toghi Eshghi, Amin; Lee, Soobum; Kazem Sadoughi, Mohammad; Hu, Chao; Kim, Young-Cheol; Seo, Jong-Ho

    2017-10-01

    Energy harvesting (EH) technologies to power small sized electronic devices are attracting great attention. Wasted energy in a vehicle’s rotating tire has a great potential to enable self-powered tire pressure monitoring sensors (TPMS). Piezoelectric type energy harvesters can be used to collect vibrational energy and power such systems. Due to the presence of harsh acceleration in a rotating tire, a design tradeoff needs to be studied to prolong the harvester’s fatigue life as well as to ensure sufficient power generation. However, the design by traditional deterministic design optimization (DDO) does not show reliable performance due to the lack of consideration of various uncertainty factors (e.g., manufacturing tolerances, material properties, and loading conditions). In this study, we address a new EH design formulation that considers the uncertainty in car speed, dimensional tolerances and material properties, and solve this design problem using reliability-based design optimization (RBDO). The RBDO problem is formulated to maximize compactness and minimize weight of a TPMS harvester while satisfying power and durability requirements. A transient analysis has been done to measure the time varying response of EH such as power generation, dynamic strain, and stress. A conservative design formulation is proposed to consider the expected power from varied speed and stress at higher speed. When compared to the DDO, the RBDO results show that the reliability of EH is increased significantly by scarifying the objective function. Finally, experimental test has been conducted to demonstrate the merits of RBDO design over DDO.

  5. Indirect Tire Monitoring System - Machine Learning Approach

    Science.gov (United States)

    Svensson, O.; Thelin, S.; Byttner, S.; Fan, Y.

    2017-10-01

    The heavy vehicle industry has today no requirement to provide a tire pressure monitoring system by law. This has created issues surrounding unknown tire pressure and thread depth during active service. There is also no standardization for these kind of systems which means that different manufacturers and third party solutions work after their own principles and it can be hard to know what works for a given vehicle type. The objective is to create an indirect tire monitoring system that can generalize a method that detect both incorrect tire pressure and thread depth for different type of vehicles within a fleet without the need for additional physical sensors or vehicle specific parameters. The existing sensors that are connected communicate through CAN and are interpreted by the Drivec Bridge hardware that exist in the fleet. By using supervised machine learning a classifier was created for each axle where the main focus was the front axle which had the most issues. The classifier will classify the vehicles tires condition and will be implemented in Drivecs cloud service where it will receive its data. The resulting classifier is a random forest implemented in Python. The result from the front axle with a data set consisting of 9767 samples of buses with correct tire condition and 1909 samples of buses with incorrect tire condition it has an accuracy of 90.54% (0.96%). The data sets are created from 34 unique measurements from buses between January and May 2017. This classifier has been exported and is used inside a Node.js module created for Drivecs cloud service which is the result of the whole implementation. The developed solution is called Indirect Tire Monitoring System (ITMS) and is seen as a process. This process will predict bad classes in the cloud which will lead to warnings. The warnings are defined as incidents. They contain only the information needed and the bandwidth of the incidents are also controlled so incidents are created within an

  6. Improvement of wheel skidder tractive performance by tire inflation pressure and tire chains

    OpenAIRE

    Stoilov, Stanimir

    2007-01-01

    The motion resistance ratio, gross traction ratio and net traction ratio of a wheel cable skidder were determined and mathematical models derived for three tire inflation pressure values with or without tire chains on forest road in mountainous conditions. The motion resistance ratio increases with the increase of tire inflation pressure. On the contrary, the gross traction ratio increases with the decrease of tire inflation pressure. However, when the tires are equipped with tire chains t...

  7. Full-scale aircraft tire pressure tests

    OpenAIRE

    FABRE, C; BALAY, Jean Maurice; LERAT, P; MAZARS, A

    2009-01-01

    This paper describes an outdoor full-scale test planned to improve experimental and theoretical knowledge related to the effects of aircraft internal tire inflation pressure on the behavior and damage of flexible pavement. Since modern aircraft can have tire pressures greater than 15 bar, the tests will focus on pressures from 15 bar to 17.5 bar. The experimental pavement located on the Toulouse-Blagnac airport in France will include up to seven al different test sections, representative of c...

  8. Full-scale aicraft tire pressure tests

    OpenAIRE

    FABRE, C; BALAY, Jean Maurice; LERAT, P; MAZARS, A

    2009-01-01

    This paper describes an outdoor full-scale test planned to improve experimental and theoretical knowledge related to the effects of aircraft internal tire inflation pressure on the behavior and damage of flexible pavement. Since modern aircraft can have tire pressures greater than 15 bar, the tests focus on pressures from 15 to 17.5 bar. The experimental pavement located on the Toulouse-Blagnac airport in France will include up to seven al different test sections, representative of current ai...

  9. Effect of wheelchair mass, tire type and tire pressure on physical strain and wheelchair propulsion technique.

    Science.gov (United States)

    de Groot, Sonja; Vegter, Riemer J K; van der Woude, Lucas H V

    2013-10-01

    The purpose of this study was to evaluate the effect of wheelchair mass, solid vs. pneumatic tires and tire pressure on physical strain and wheelchair propulsion technique. 11 Able-bodied participants performed 14 submaximal exercise blocks on a treadmill with a fixed speed (1.11 m/s) within 3 weeks to determine the effect of tire pressure (100%, 75%, 50%, 25% of the recommended value), wheelchair mass (0 kg, 5 kg, or 10 kg extra) and tire type (pneumatic vs. solid). All test conditions (except pneumatic vs. solid) were performed with and without instrumented measurement wheels. Outcome measures were power output (PO), physical strain (heart rate (HR), oxygen uptake (VO2), gross mechanical efficiency (ME)) and propulsion technique (timing, force application). At 25% tire pressure PO and subsequently VO2 were higher compared to 100% tire pressure. Furthermore, a higher tire pressure led to a longer cycle time and contact angle and subsequently lower push frequency. Extra mass did not lead to an increase in PO, physical strain or propulsion technique. Solid tires led to a higher PO and physical strain. The solid tire effect was amplified by increased mass (tire × mass interaction). In contrast to extra mass, tire pressure and tire type have an effect on PO, physical strain or propulsion technique of steady-state wheelchair propulsion. As expected, it is important to optimize tire pressure and tire type. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  10. Assessment of wheel propeller contact pressure upon soil with use of tire universal performance

    Directory of Open Access Journals (Sweden)

    Z. A. Godzhaev

    2016-01-01

    Full Text Available A maximum contact pressure is a key parameter characterizing a level of ecological impact of tractor propellers on the soil. The maximum pressure upon the soil varies with internal pressure in tires and vertical load of a wheel. An universal tire performance can be used at an assessment of change of contact pressure of a wheel propeller upon the soil. The authors offered a technique of definition and regulation of the maximum contact pressure of the wheel propeller upon the basic basis. This technique allows to set parameters for monitoring systems and regulation of the maximum pressure upon the soil by measurement of a tire deflection and change of pressure in tires. At statistical tests for determination of the maximum contact pressure it is necessary to consider the universal performance of the tire nomographically. This nomogram allows to consider visually influence of loading and internal pressure in the tire on a size of the maximum contact pressure. An internal pressure decrease in the tire makes it possible to reduce the maximum pressure upon the soil at constant loading. The authors investigated universal performances of the tires in the range of change of internal air pressure from 160 to 90 kPas. Change of internal pressure from 150 to 100 kPas reduce for the tire 15,5R38 the maximum contact pressure upon 13 kPas (9,6 percent: from 135 to 122 kPas. That corresponds to the admissible level of pressure upon the soil at its humidity in a layer of 0-30 cm: 0,5-0,6 minimum moisture-holding capacity during the spring period and 0,6-0,7 minimum moisture-holding capacity during the autumn period. In case of use of the tire 16,9R38 the maximum pressure upon the soil decreases from 84 to 75 kPas, that is by 10,4 percent.

  11. A Tire Air Maintenance Technology

    Science.gov (United States)

    Pierce, Alan

    2012-01-01

    Improperly inflated car tires can reduce gas mileage and car performance, speed up tire wear, and even cause a tire to blow out. The AAA auto club recommends that someone check the air pressure of one's car's tires at least once a month. Wouldn't it be nice, though, if someone came up with a tire pressure-monitoring system that automatically kept…

  12. Evaluation of the tire pressure influence on the lateral forces that occur between tire and road

    Science.gov (United States)

    Cordoş, N.; Todoruţ, A.; Barabás, I.

    2017-10-01

    The main objective of the paper is to capture the behavior of a vehicle on a race circuit, depending on the different inflation pressures of the tires (underpressure and overpressure). Taking into account that in the cornering the forces and the moments of inertia rise due the vehicle mass, and an inertial force decomposes in two components, one in the longitudinal plane and one in the transverse plane, the work aims the assessing the lateral forces that appear, to the contact between the tires and the tread, depending on the inflation pressure. The results have a graphic interpretation, enabling a comparative study of them. Results have been obtained regarding the lateral tire forces that occur between the tire and the road. The differences between these forces were particularly noticeable in cornering, and the differences between these forces were interpreted according to the tire inflation pressure.

  13. Effect of wheelchair mass, tire type and tire pressure on physical strain and wheelchair propulsion technique

    NARCIS (Netherlands)

    de Groot, Sonja; Vegter, Riemer J. K.; van der Woude, Lucas H. V.

    2013-01-01

    The purpose of this study was to evaluate the effect of wheelchair mass, solid vs. pneumatic tires and tire pressure on physical strain and wheelchair propulsion technique. 11 Able-bodied participants performed 14 submaximal exercise blocks on a treadmill with a fixed speed (1.11 m/s) within 3 weeks

  14. Dynamic tire pressure sensor for measuring ground vibration.

    Science.gov (United States)

    Wang, Qi; McDaniel, James Gregory; Wang, Ming L

    2012-11-07

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.

  15. Tires

    Science.gov (United States)

    2015-12-15

    measure heat from the casing. Tread surface temperature. Tread (surface) infrared temperature can be inconsistent since the measurements are...have any adverse effect on rubber products. b. Avoid areas that are wet, humid, oily, greasy, or in direct sunlight. Do not store tires in the...used, from sticking to the tire. Do not let soapstone accumulate in the tire. Inspect and clean the tire beads to remove corrosion or residual rubber

  16. Tire

    Science.gov (United States)

    Benzing, II, James Alfred (Inventor); Kish, James Christopher (Inventor); Asnani, Vivake Manohar (Inventor)

    2012-01-01

    A tire includes a plurality of helical springs. Each helical spring includes a first end portion, a second end portion, and an arching middle portion. Each helical spring is interlaced with at least one other helical spring thereby forming a laced toroidal structure extending about an entire circumference of the tire.

  17. Piezoelectric power generation for sensor applications: design of a battery-less wireless tire pressure sensor

    Science.gov (United States)

    Makki, Noaman; Pop-Iliev, Remon

    2011-06-01

    An in-wheel wireless and battery-less piezo-powered tire pressure sensor is developed. Where conventional battery powered Tire Pressure Monitoring Systems (TPMS) are marred by the limited battery life, TPMS based on power harvesting modules provide virtually unlimited sensor life. Furthermore, the elimination of a permanent energy reservoir simplifies the overall sensor design through the exclusion of extra circuitry required to sense vehicle motion and conserve precious battery capacity during vehicle idling periods. In this paper, two design solutions are presented, 1) with very low cost highly flexible piezoceramic (PZT) bender elements bonded directly to the tire to generate power required to run the sensor and, 2) a novel rim mounted PZT harvesting unit that can be used to power pressure sensors incorporated into the valve stem requiring minimal change to the presently used sensors. While both the designs eliminate the use of environmentally unfriendly battery from the TPMS design, they offer advantages of being very low cost, service free and easily replaceable during tire repair and replacement.

  18. A Multisensing Setup for the Intelligent Tire Monitoring.

    Science.gov (United States)

    Coppo, Francesco; Pepe, Gianluca; Roveri, Nicola; Carcaterra, Antonio

    2017-03-12

    The present paper offers the chance to experimentally measure, for the first time, the internal tire strain by optical fiber sensors during the tire rolling in real operating conditions. The phenomena that take place during the tire rolling are in fact far from being completely understood. Despite several models available in the technical literature, there is not a correspondently large set of experimental observations. The paper includes the detailed description of the new multi-sensing technology for an ongoing vehicle measurement, which the research group has developed in the context of the project OPTYRE. The experimental apparatus is mainly based on the use of optical fibers with embedded Fiber Bragg Gratings sensors for the acquisition of the circumferential tire strain. Other sensors are also installed on the tire, such as a phonic wheel, a uniaxial accelerometer, and a dynamic temperature sensor. The acquired information is used as input variables in dedicated algorithms that allow the identification of key parameters, such as the dynamic contact patch, instantaneous dissipation and instantaneous grip. The OPTYRE project brings a contribution into the field of experimental grip monitoring of wheeled vehicles, with implications both on passive and active safety characteristics of cars and motorbikes.

  19. A Multisensing Setup for the Intelligent Tire Monitoring

    Directory of Open Access Journals (Sweden)

    Francesco Coppo

    2017-03-01

    Full Text Available The present paper offers the chance to experimentally measure, for the first time, the internal tire strain by optical fiber sensors during the tire rolling in real operating conditions. The phenomena that take place during the tire rolling are in fact far from being completely understood. Despite several models available in the technical literature, there is not a correspondently large set of experimental observations. The paper includes the detailed description of the new multi-sensing technology for an ongoing vehicle measurement, which the research group has developed in the context of the project OPTYRE. The experimental apparatus is mainly based on the use of optical fibers with embedded Fiber Bragg Gratings sensors for the acquisition of the circumferential tire strain. Other sensors are also installed on the tire, such as a phonic wheel, a uniaxial accelerometer, and a dynamic temperature sensor. The acquired information is used as input variables in dedicated algorithms that allow the identification of key parameters, such as the dynamic contact patch, instantaneous dissipation and instantaneous grip. The OPTYRE project brings a contribution into the field of experimental grip monitoring of wheeled vehicles, with implications both on passive and active safety characteristics of cars and motorbikes.

  20. Effect of Tire Pressure to Physical Workload at Operating a Manual Wheelchair.

    Science.gov (United States)

    Booka, Masayuki; Yoneda, Ikuo; Hashizume, Tsutomu; Lee, Hokyoo; Oku, Hidehisa; Fujisawa, Shoichiro

    2015-01-01

    It is often experienced that low tire pressure of the wheelchair not only increases running resistance, but also reduces parking brake performance. In this study, the required driving forces for different tire pressures were experimentally measured and evaluated. It was indicated from the result that the wheelchair with proper tire pressure could be run with less workload of wheelchair-user. Then it was also indicated that the wheelchair with a lower tire pressure needed more workload of wheelchair-user even on hard level surface.

  1. Development and applicability estimation of the tire contact pressure measurement system; Tire secchiatsukei no kaihatsu to oyosei hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Mizutani, Y.; Amago, T.; Takahashi, T.; Sakuma, S.; Mori, N. [Toyota Central R and D Laboratories, Inc., Aichi (Japan); Nagae, A. [Toyota Motor Corp., Aichi (Japan); Yasuoka, M. [Toyo Tire and Rubber Co. Ltd., Osaka (Japan)

    1995-04-20

    A pressure sensor more reliable than the conventional types and a tire pressure measurement system using a plurality of sensors of the said reliable type have been developed. The sensor is an inverted T in shape, the upper surface of the vertical beam thereof receives the pressure, and the two ends of the horizontal beam are fixed. The load per unit area imposed on the pressure receiving surface is separated into three components, the X and Y components in the tangential direction are sensed by the vertical beam while the Z component in the vertical direction is sensed by a distortion gauge attached to the horizontal beam. For the measurement of the contact pressure distribution for the entire contact surface, a measuring device was developed, comprising a multiple point contact pressure gauge with 30 sensors of the reliable type discussed here embedded therein, a tire rolling tester, and a data processing unit. A tire wear estimation test was conducted using this pressure sensor and a contact probe type slip sensor, and it was found that a tire of a greater friction energy ratio is easier to experience abnormal abrasion and that the new pressure sensor is useful in estimating abnormal abrasion. Further, it was indicated that the present measuring device is applicable to the analysis of the mechanism wherein shaft force results from contact pressure on the soil. 3 refs., 11 figs., 3 tabs.

  2. Tire-rim interface pressure of a commercial vehicle wheel under radial loads: theory and experiment

    Science.gov (United States)

    Wan, Xiaofei; Shan, Yingchun; Liu, Xiandong; He, Tian; Wang, Jiegong

    2017-11-01

    The simulation of the radial fatigue test of a wheel has been a necessary tool to improve the design of the wheel and calculate its fatigue life. The simulation model, including the strong nonlinearity of the tire structure and material, may produce accurate results, but often leads to a divergence in calculation. Thus, a simplified simulation model in which the complicated tire model is replaced with a tire-wheel contact pressure model is used extensively in the industry. In this paper, a simplified tire-rim interface pressure model of a wheel under a radial load is established, and the pressure of the wheel under different radial loads is tested. The tire-rim contact behavior affected by the radial load is studied and analyzed according to the test result, and the tire-rim interface pressure extracted from the test result is used to evaluate the simplified pressure model and the traditional cosine function model. The results show that the proposed model may provide a more accurate prediction of the wheel radial fatigue life than the traditional cosine function model.

  3. Load and inflation pressure effects on soil compaction of forwarder tires

    Science.gov (United States)

    Tim McDonald; Tom Way; Bjorn Lofgren; Fernando Seixas; Mats Landstrom

    1996-01-01

    A standard forwarder tire (600/55-26.5) was tested to determine its range of soil compaction with various inflation pressures and dynamic loads. Past research has shown that compaction of heavier equipment can be somewhat mitigated by operating with lower inflation pressures. Results indicated a significant effect of both load and inflation pressure on bulk density,...

  4. Intracranial Pressure Monitoring

    DEFF Research Database (Denmark)

    Raboel, P H; Bartek, J; Andresen, M

    2012-01-01

    Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods...

  5. Investigation of the impact of noise exposure on blood pressure in tire manufacturing workers

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Baneshi

    2012-12-01

    Full Text Available    BACKGROUND: Noise can cause serious health problems. Regular use of personal health equipments can reduce such problems. This study has been designed to compare the blood pressure of tire manufacturing workers, who were exposed to noise (> 85 db and used personal health equipment, with a control group without noise exposure.    METHODS: In this case-control study, 70 workers who were exposed to noise (case group and 220 workers who were not (control group were recruited. Regular use of personal health equipment was compulsory. LEQ was calculated for both groups. To analyse the data, chi-square test and t-test were implemented. Finally multivariate regression model was developed.    RESULTS: No difference was seen between the groups in terms of basic characteristics (age, years of working, and BMI. Mean systolic blood pressure in case and control groups was 116.6 and 117.5, respectively; giving a P-value of 0.50. Mean diastolic blood pressure in case and control groups was 76.7 and 77.4, respectively; giving a P-value of 0.47. Results indicate no significant difference between blood pressure of cases and control groups.    CONCLUSION: We did not see any significant difference between the blood pressure of those exposed to noise, and regularly using personal health equipment, and those in the control group without noise exposure. Therefore, we strongly recommend use of such equipments.       Keywords: Tires Factory, Blood Pressure, Noise Exposure

  6. Optical strain measurement for fault detection in haul-truck tires

    International Nuclear Information System (INIS)

    Kotchon, A; Nobes, D S; Lipsett, M G

    2012-01-01

    Tire condition is integral to the safe operation of heavy machinery, such as ultra-class haul trucks. A new approach to haul truck tire monitoring is being investigated based on optical strain measurement, which has the advantage of providing quantitative information from sensors that do not contact the tire. A laboratory-scale apparatus has been constructed to monitor a tire as it is subjected to various loads and pressures. Digital image correlation is used to calculate the deformation in the tire. Using this method, damage resulting from a horizontal and vertical cut created on the tire surface could be detected. A three-dimensional surface reconstruction of the tire was created to assist in the characterization of more complex damage types such as wear and fatigue. In addition to providing information for a possible industrial scale damage detection system, this apparatus will also further the understanding of damage mechanisms in tires.

  7. Improving mechanical grip on winter tires. Finite element analysis on pressure profile of airless tire compared to conventional tire using ANSYS workbench

    OpenAIRE

    Ludvigsen, Sondre

    2017-01-01

    The harsh climate of the arctic has always been one of the most difficult areas to drive cars in. The severe loss in traction due to snow and icing on the roads, has led to an increased risk of collisions. The winter tires for cars has developed through the years after their introduction in the 1930’s. There have been three revolutionary changes made since then; implement of studs, changing in tread pattern and optimizing rubber characteristics. The implementation of studs is being shied away...

  8. Blood pressure monitors for home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... may ask you to keep track of your blood pressure at home. To do this, you will need ...

  9. Tire Log™

    OpenAIRE

    ECT Team, Purdue

    2013-01-01

    The Tire Log™ is a patented innovation made from waste tires with a unique and energy efficient approach to recycling tires. Re-Tread Products (RTP) process takes full advantage of the embedded energy in tires that is wasted in conventional tire recycling that primarily involves the grinding, burying or burning of waste tires.

  10. Tyre noise predictions from computed road surface texture induced contact pressure; Romen no outotsu ni kiinsuru sesshoku atsuryoku ni yoru tire soon no suitei

    Energy Technology Data Exchange (ETDEWEB)

    Mikami, T. [Japan Automobile Research Institute Inc., Tsukuba (Japan)

    1999-07-01

    A method for tire/road noise prediction is studied based on the result of road surface profile measurement (horizontal direction measurement interval 3mm, horizontal direction measurement accuracy 8{mu}m, distance measured 1655m, using a laser-aided profile meter). The obtained road surface profile is used for the calculation of contact pressure that occurs between the tire tread and road surface (using the 2-dimensional calculation model of Clapp et al.). For the examination of the relationship between the contact pressure and generated noise, tire noise is measured using a microphone array provided near the tire circumference. The frequency spectral ratio between the generated noise and contact pressure is determined as a transmission function. It may be said that the transmission function is unique to the tire, not dependent on the road surface profile. The road surface profile is determined by use of the transmission function, and this enables the prediction of the noise from the tire. Noises were measured on several kinds of road surfaces different in coarseness for a passenger car and truck, and the values from these actual measurements are compared with the predicted values, and then it is found that the prediction model is valid. (NEDO)

  11. Haul truck tire dynamics due to tire condition

    International Nuclear Information System (INIS)

    Anzabi, R Vaghar; Nobes, D S; Lipsett, M G

    2012-01-01

    Pneumatic tires are costly components on large off-road haul trucks used in surface mining operations. Tires are prone to damage during operation, and these events can lead to injuries to personnel, loss of equipment, and reduced productivity. Damage rates have significant variability, due to operating conditions and a range of tire fault modes. Currently, monitoring of tire condition is done by physical inspection; and the mean time between inspections is often longer than the mean time between incipient failure and functional failure of the tire. Options for new condition monitoring methods include off-board thermal imaging and camera-based optical methods for detecting abnormal deformation and surface features, as well as on-board sensors to detect tire faults during vehicle operation. Physics-based modeling of tire dynamics can provide a good understanding of the tire behavior, and give insight into observability requirements for improved monitoring systems. This paper describes a model to simulate the dynamics of haul truck tires when a fault is present to determine the effects of physical parameter changes that relate to faults. To simulate the dynamics, a lumped mass 'quarter-vehicle' model has been used to determine the response of the system to a road profile when a failure changes the original properties of the tire. The result is a model of tire vertical displacement that can be used to detect a fault, which will be tested under field conditions in time-varying conditions.

  12. Haul truck tire dynamics due to tire condition

    Science.gov (United States)

    Vaghar Anzabi, R.; Nobes, D. S.; Lipsett, M. G.

    2012-05-01

    Pneumatic tires are costly components on large off-road haul trucks used in surface mining operations. Tires are prone to damage during operation, and these events can lead to injuries to personnel, loss of equipment, and reduced productivity. Damage rates have significant variability, due to operating conditions and a range of tire fault modes. Currently, monitoring of tire condition is done by physical inspection; and the mean time between inspections is often longer than the mean time between incipient failure and functional failure of the tire. Options for new condition monitoring methods include off-board thermal imaging and camera-based optical methods for detecting abnormal deformation and surface features, as well as on-board sensors to detect tire faults during vehicle operation. Physics-based modeling of tire dynamics can provide a good understanding of the tire behavior, and give insight into observability requirements for improved monitoring systems. This paper describes a model to simulate the dynamics of haul truck tires when a fault is present to determine the effects of physical parameter changes that relate to faults. To simulate the dynamics, a lumped mass 'quarter-vehicle' model has been used to determine the response of the system to a road profile when a failure changes the original properties of the tire. The result is a model of tire vertical displacement that can be used to detect a fault, which will be tested under field conditions in time-varying conditions.

  13. Fuel Economy and Emissions Effects of Low Tire Pressure, Open Windows, Roof Top and Hitch-Mounted Cargo, and Trailer

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, John F [ORNL; Huff, Shean P [ORNL; West, Brian H [ORNL

    2014-01-01

    To quantify the fuel economy (FE) effect of some common vehicle accessories or alterations, a compact passenger sedan and a sport utility vehicle (SUV) were subjected to SAE J2263 coastdown procedures. Coastdowns were conducted with low tire pressure, all windows open, with a roof top or hitch-mounted cargo carrier, and with the SUV pulling an enclosed cargo trailer. From these coastdowns, vehicle dynamometer coefficients were developed which enabled the execution of vehicle dynamometer experiments to determine the effect of these changes on vehicle FE and emissions over standard drive cycles and at steady highway speeds. The FE penalty associated with the rooftop cargo box mounted on the compact sedan was as high as 25-27% at higher speeds, where the aerodynamic drag is most pronounced. For both vehicles, use of a hitch mounted cargo tray carrying a similar load resulted in very small FE penalties, unlike the rooftop cargo box. The results for the SUV pulling a 3500 pound enclosed cargo trailer were rather dramatic, resulting in FE penalties ranging from 30%, for the city cycle, to 50% at 80 mph, at which point significant CO generation indicated protective enrichment due to high load. Low tire pressure cases resulted in negligible to 10% FE penalty depending on the specific case and test point. Driving with all four windows open decreased FE by 4-8.5% for the compact sedan, and 1-4% for the SUV.

  14. Spring Tire

    Science.gov (United States)

    Asnani, Vivake M.; Benzing, Jim; Kish, Jim C.

    2011-01-01

    The spring tire is made from helical springs, requires no air or rubber, and consumes nearly zero energy. The tire design provides greater traction in sandy and/or rocky soil, can operate in microgravity and under harsh conditions (vastly varying temperatures), and is non-pneumatic. Like any tire, the spring tire is approximately a toroidal-shaped object intended to be mounted on a transportation wheel. Its basic function is also similar to a traditional tire, in that the spring tire contours to the surface on which it is driven to facilitate traction, and to reduce the transmission of vibration to the vehicle. The essential difference between other tires and the spring tire is the use of helical springs to support and/or distribute load. They are coiled wires that deform elastically under load with little energy loss.

  15. Pressão de insuflagem dos pneus no desempenho do conjunto trator-grade de discos Tire inflation pressure effects on tractor disc harrow performance

    Directory of Open Access Journals (Sweden)

    João Manuel Pereira Ramalho Serrano

    2008-02-01

    Full Text Available O objetivo deste trabalho foi avaliar o efeito da pressão de insuflagem dos pneus nos parâmetros de desempenho do conjunto trator-grade de discos. As pressões avaliadas foram: 100 kPa nos pneus da frente e 70 kPa nos pneus atrás; 140 kPa nos quatro pneus; 190 kPa nos quatro pneus. Os testes de um trator com grades de discos foram desenvolvidos em condições de campo, em solos de textura franca, mobilizados e secos. Os parâmetros de avaliação foram: o patinamento, a velocidade, a capacidade de trabalho, a eficiência energética global e o consumo de combustível por hectare. Entre as situações de pressão de insuflagem dos pneus indicadas pelo fabricante do trator e a pressão de insuflagem indicada pelo fabricante dos pneus, não se verificam diferenças significativas, tanto na capacidade de trabalho como no consumo de combustível por hectare. A utilização de elevadas pressões de insuflagem dos pneus conduz a uma redução da ordem de 3 a 5% na capacidade de trabalho e um aumento significativo entre 10 e 25% do consumo de combustível por hectare, mesmo em condições de boa aderência dos pneus, refletidas no intervalo de 7 a 15% de patinamento registrados.The objective of this work was to evaluate the tire inflation pressure effects on tractor disc harrow performance. The pressures tested were: 100 kPa in front tires and 70 kPa in rear tires; 140 kPa in the tires of both axles; 190 kPa in the tires of both axles. Field tests with disc harrow in secondary tillage were performed under real working conditions, in tilled and dry medium textured soils. The evaluation parameters were: the slip, the actual forward speed, the work capacity, the overall energy efficiency and the fuel consumption per hectare. Concerning the situations of tire inflation pressure specified by the tractor manufacturer and the inflation pressure specified by the tire manufacturer, there were no significant differences, both in work capacity and in fuel

  16. Influence of tire inflating pressure at dynamic forces acting on articulated trolleybus

    Directory of Open Access Journals (Sweden)

    Polach Pavel

    2017-01-01

    Full Text Available ŠKODA VÝZKUM s.r.o. cooperated on the development of the NEOPLAN DMA low-floor articulated trolleybus intended for the Boston city. Multibody models and finite element models of the trolleybus were utilized in the stage of the vehicle design. At the end of the stage of computer modelling and testing of the trolleybus prototype a decision to reduce tire inflating of vehicles in serial production (together with the change the type of shock absorbers used in trolleybus suspension was made. The impact of this change on forces acting in the trolleybus suspension elements (i.e. in air springs and shock absorbers and radius rods on the trolleybus chassis when running on an uneven test track was investigated using multibody simulations. Time histories of the forces calculated utilising multibody models were used as input data of the trolleybus finite element models.

  17. Aschroft Pressure Switch - Monitor for Low SCHe Supply Bottle Pressure

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    These pressure switches are located in the SCHe helium supply lines at the pressure bottles and upstream of the PRV. The switches monitor the SCHe supply bottle pressure and are set to alarm at 2200 psig. There is one switch for each SCHe supply (4). Electronic output signal is NON-SAFETY (GS)

  18. Configurations Of Tire Pressure On The Pavement For Commercial Vehicles: Calculation Of The ‘N’ Number And The Consequences On Pavement Performance

    Directory of Open Access Journals (Sweden)

    Paulo Boulos Filho

    2016-07-01

    Full Text Available Road traffic has a high variety of types of vehicles and cargo transported. One of the main difficulties in pavement design is forecasting the changes in traffic over time and evaluating the comparative deterioration power of the various loads with axle and tire settings and different levels of repetition. The road environment in Brazil, as we know, is the main means of the country's cargo transportation. Throughout the 1990s and 2000s the road modal accounted for over 60% of the total cargo transported in the country leaving the unbalanced Brazilian transport matrix with almost exclusive investments in such means of transportation. According to CNT 2012, which conducted a survey in approximately 45% of the paved network, evaluating the pavement functional conditions, traffic signs and geometry, 46% of the country’s road network has some type of deficiency in the pavement. The goal of this work is to contribute to a better understanding of the complex influence of traffic in the design and service life of the pavement. The load pressure of commercial vehicle tires over the pavement has increased in recent decades. A more apparent effect of this increase in tire pressure would be the change in the pavement- tire contact area which in turn may result in an increase in the contact load between tire and pavement and other harmful effects on the structure. This study aims to determine the effect on the calculation of the N number, or the number of solicitations of the standard axle on the road pavement, measuring the overload as a percentage of the legal load indicated by a scale. In short, we calculate how an increase in the overload percentage in comparison with the allowable load will influence the decrease of the calculated durability of the pavement designed for the highway.

  19. Microoptomechanical sensor for intracranial pressure monitoring

    International Nuclear Information System (INIS)

    Andreeva, A V; Luchinin, V V; Lutetskiy, N A; Sergushichev, A N

    2014-01-01

    The main idea of this research is the development of microoptomechanical sensor for intracranial pressure monitoring. Currently, the authors studied the scientific and technical knowledge in this field, as well as develop and test a prototype of microoptomechanical sensor for intracranial pressure (ICP) monitoring

  20. Side effects of ambulatory blood pressure monitoring.

    NARCIS (Netherlands)

    Steen, M.S. van der; Lenders, J.W.M.; Thien, Th.

    2005-01-01

    OBJECTIVE: To study the experiences and complaints of patients who underwent 24 h blood pressure monitoring. METHODS: Two groups of hypertensive patients of a tertiary outpatient clinic were asked to fill in a nine-item questionnaire about the side effects of ambulatory blood pressure monitoring

  1. Reotemp Pressure Indicator - Local Pressure Indication to Monitor the SCHe Supply Bottle Pressure

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    1999-01-01

    These 0-3000 psig range pressure indicators are located in the SCHe helium supply lines at the pressure bottles and upstream of the PRV. These accident monitoring local pressure indicators monitor the SCHe supply bottle pressure. There is one pressure indicator for each SCHe supply (4)

  2. Investigation of the Effects of Tire Inflation Pressure and Forward Speed of Driven Wheel on Horizontal Impact of Passing Rectangular Obstacle

    Directory of Open Access Journals (Sweden)

    H Mohammadzadeh

    2013-09-01

    Full Text Available The tire-mechanics models have been developed for the study of wheel movement on the road or soil surface while these models are unlikely to describe the motion of wheels on uneven surfaces. Due to dynamical complexity of this phenomena and the importance of this subject for farm conditions and the wheel carrier devices, the present research aimed to investigate the effects of several parameters on the wheel passing the obstacle. The experiments were carried out using single wheel tester in soil bin condition. The results indicated a relatively linear relationship between the impact force applied on tire and forward speed of wheel and also the height of rectangular obstacle. The effect of inflation pressure was inversed in the range of complete formed tire’s body on impact force and in low levels of tire inflation pressure; tire’s body damps the maximum impact forces. The medium levels of pressure (about 150-200 kPa resulted in less horizontal force that applied on the wheel for different levels of forward speed and obstacle’s height. Tractive force for passing obstacle was increased by raising forward speed and the obstacle’s height.

  3. Tire Recycling

    Science.gov (United States)

    1997-01-01

    Cryopolymers, Inc. tapped NASA expertise to improve a process for recycling vehicle tires by converting shredded rubber into products that can be used in asphalt road beds, new tires, hoses, and other products. In conjunction with the Southern Technology Applications Center and Stennis Space Center, NASA expertise in cryogenic fuel-handling needed for launch vehicle and spacecraft operations was called upon to improve the recycling concept. Stennis advised Cryopolymers on the type of equipment required, as well as steps to reduce the amount of liquid nitrogen used in the process. They also guided the company to use more efficient ways to control system hardware. It is estimated that more than 300 million tires nationwide are produced per year. Cryopolymers expects to reach a production rate of 5,000 tires recycled per day.

  4. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  5. Pressure monitoring during neuroendoscopy : new insights

    NARCIS (Netherlands)

    Dewaele, F.; Kalmar, A. F.; Van Canneyt, K.; Vereecke, H.; Absalom, A.; Caemaert, J.; Struys, M. M. R. F.; Van Roost, D.

    Background. Significant increases in intracranial pressure (ICP) may occur during neuroendoscopic procedures. To detect and prevent serious and sustained increases, ICP should be monitored. At present, controversy exists on the optimal location of the monitoring sensor. Therefore, we conducted an in

  6. Organic electronics based pressure sensor towards intracranial pressure monitoring

    Science.gov (United States)

    Rai, Pratyush; Varadan, Vijay K.

    2010-04-01

    The intra-cranial space, which houses the brain, contains cerebrospinal fluid (CSF) that acts as a fluid suspension medium for the brain. The CSF is always in circulation, is secreted in the cranium and is drained out through ducts called epidural veins. The venous drainage system has inherent resistance to the flow. Pressure is developed inside the cranium, which is similar to a rigid compartment. Normally a pressure of 5-15 mm Hg, in excess of atmospheric pressure, is observed at different locations inside the cranium. Increase in Intra-Cranial Pressure (ICP) can be caused by change in CSF volume caused by cerebral tumors, meningitis, by edema of a head injury or diseases related to cerebral atrophy. Hence, efficient ways of monitoring ICP need to be developed. A sensor system and monitoring scheme has been discussed here. The system architecture consists of a membrane less piezoelectric pressure sensitive element, organic thin film transistor (OTFT) based signal transduction, and signal telemetry. The components were fabricated on flexible substrate and have been assembled using flip-chip packaging technology. Material science and fabrication processes, subjective to the device performance, have been discussed. Capability of the device in detecting pressure variation, within the ICP pressure range, is investigated and applicability of measurement scheme to medical conditions has been argued for. Also, applications of such a sensor-OTFT assembly for logic sensor switching and patient specific-secure monitoring system have been discussed.

  7. 49 CFR 571.119 - Standard No. 119; New pneumatic tires for motor vehicles with a GVWR of more than 4,536 kilograms...

    Science.gov (United States)

    2010-10-01

    ... without interruption. (e) Immediately after running the tire the required time, measure the tire inflation...) Immediately after running the tire the required time, measure the tire inflation pressure. Remove the tire... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 119; New pneumatic tires for motor...

  8. Performance of an agricultural tractor in no tillage as a function of displacement speed and the seeders' tire inflation pressure

    Energy Technology Data Exchange (ETDEWEB)

    Furlani, Carlos Eduardo Angeli; Cortez, Jorge Wilson; Silva, Rouverson Pereira da; Grotta, Danilo Cesar Checchio; Toledo, Anderson de [Universidade Estadual Paulista (UNESP), Jaboticabal, SP (Brazil)], E-mail: furlani@fcav.unesp.br

    2008-07-01

    The performance of an agricultural tractor under field conditions results from the tire wheel interaction together with its displacement speed. This work was developed to assess the performance of an agricultural tractor under the (75, 70, and 60 psi) tire inflation pressure conditions of a seeder and in two different gears providing speeds of 3.0 and 6.0 km h{sup -1}. The experiment took place at Sao Paulo State University (UNESP), at the Jaboticabal Campus, and was conducted by Laboratory of Machines and Agricultural Mechanization (LAMMA) at the Department of Rural Engineering. The delineation used was entirely randomized in a 2-factor factorial scheme (3 x 2) with 4 repetitions. We also observed that fuel consumption was influenced only by the tractor gear. Energy consumption was greater as speed increased, caused by gear shifting. The displacement speed was greater for the 75-psi pressure due to a lesser slippage in the seeder when under this pressure. Tractor slippage and initial stand did not change with the tested factors. (author)

  9. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  10. Riding on air: critical safety information for you and your tires

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-07-01

    This booklet is issued for public distribution by Transport Canada. It provides a few simple tips concerning automobile tire safety which, if followed, is expected to result in increased personal and vehicle safety, improved fuel economy, prolonged tire life, energy savings and reduced environmental pollution. The information provided include tips about tire pressure, tire inspection for damage and wear, rotation of tires for more even wear, replacing worn tires, the advantages of using snow tires in winter and an explanation of the meaning of the information found on the tire sidewall.

  11. Title: variations and sensitivities of some blood pressure monitors ...

    African Journals Online (AJOL)

    Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Accuracy in blood pressure meters is of essence to health, especially in blood pressure monitoring and treatment. The aim of this research was to compare the readings and the sensitivities of some blood pressure monitors in use ...

  12. Monitoring of Intracranial Pressure During Intracranial Endoscopy

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar

    2013-08-01

    Full Text Available Background: Intracranial endoscopy is a minimum invasive procedure, which reduces trauma to the brain, is cost-effective, and carries a shortened hospital stay with an improved postoperative outcome. Objective: To monitor intracranial pressure changes during intracranial endoscopy among children and adults under general anesthesia/sedation, and to compare the intracranial pressure changes between children and adults receiving general anesthesia and among adults receiving general anesthesia and sedation. Methods: The present cross-sectional study was conducted in one of the tertiary care hospitals of Lucknow. This was carried out in the department of neurosurgery from January 2008 to December 2008. Patients who were not fit for general anesthesia received local anesthesia under sedation. Patients participating in the study were divided into three groups. Intracranial pressure was recorded at specific intervals. Parametric data were subjected to statistical analysis using a student\\s t test. Result: A total of 70 patients were undergoing intracranial endoscopy under general anesthesia during the study period. In both groups A and B, intracranial pressure increases the maximum during inflation of the balloon. In group C, all the variations in ICP were found to be statistically significant. In the comparison of intracranial pressure changes between groups A and B, no significant difference was found. All correlations in the comparison of groups B and C were found to be statistically significant (p< 0.001. Conclusion: There is a need for continuous intraoperative monitoring of ICP intracranial endoscopy, because ICP increases in various stages of the procedure, which can be detrimental to the perfusion of the brain. [Arch Clin Exp Surg 2013; 2(4.000: 240-245

  13. Get the Most Out of Home Blood Pressure Monitoring

    Science.gov (United States)

    Get the most out of home blood pressure monitoring Checking your blood pressure at home is an important part of managing ... monitors might not give you an accurate reading. Most pharmacies, medical supply stores and some websites sell ...

  14. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad; Ouda, Mahmoud H.; Marnat, Loic; Shamim, Atif; Salama, Khaled N.

    2013-01-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  15. Implantable intraocular pressure monitoring systems: Design considerations

    KAUST Repository

    Arsalan, Muhammad

    2013-12-01

    Design considerations and limitations of implantable Intraocular Pressure Monitoring (IOPM) systems are presented in this paper. Detailed comparison with the state of the art is performed to highlight the benefits and challenges of the proposed design. The system-on-chip, presented here, is battery free and harvests energy from incoming RF signals. This low-cost design, in standard CMOS process, does not require any external components or bond wires to function. This paper provides useful insights to the designers of implantable wireless sensors in terms of design choices and associated tradeoffs. © 2013 IEEE.

  16. Monitoring of Intracranial Pressure in Meningitis.

    Science.gov (United States)

    Depreitere, Bart; Bruyninckx, Dominike; Güiza, Fabian

    2016-01-01

    The literature on intracranial pressure (ICP) monitoring in meningitis is limited to case reports and a handful of descriptive series. The aim of this study is to investigate relationships among ICP, cerebral perfusion pressure (CPP), and outcome in meningitis and to identify whether ICP affected clinical decisions. Between 1999 and 2011, a total of 17 patients with meningitis underwent ICP monitoring at the University Hospitals Leuven. Charts were reviewed for clinical history, ICP/CPP data, imaging findings, and Glasgow Outcome Scale score. Univariate correlations were computed for outcome and ICP/CPP variables, computed tomography characteristics, and Corticosteroid Randomization After Significant Head Injury outcome model variables. Treatment decisions were assessed regarding whether or not they were based on ICP. At drain placement, Glasgow Coma Scale scores showed a median of 8 (range 3-12). Six of 17 patients had either one or two nonreactive pupils. Significant correlations with outcome were found for the highest documented ICP value (r = -0.70), the number of episodes when CPP meningitis high ICP and low CPP represent secondary insults. The poor condition of the patients illustrates that the level of suspicion for increased ICP in meningitis may not be high enough.

  17. 77 FR 69541 - Technical Report Evaluating the Effectiveness of Tire Pressure Monitoring Systems (TPMS) in...

    Science.gov (United States)

    2012-11-19

    ... personal information provided. FOR FURTHER INFORMATION CONTACT: Bob Sivinski, Mathematical Statistician, Mathematical Analysis Division, NVS-421, National Center for Statistics and Analysis, National Highway Traffic...

  18. Ambulatory blood pressure monitoring (ABPM) in nonagenarians.

    Science.gov (United States)

    Formiga, Francesc; Ferrer, Assumpta; Sobrino, Javier; Coca, Antonio; Riera, Antoni; Pujol, Ramón

    2009-01-01

    The objective of the study is to investigate ambulatory blood pressure monitoring (ABPM) in a sample of Spanish nonagenarians. We also analyzed the misdiagnosis of hypertension and investigated blood pressure (BP) control in treated hypertensive nonagenarians. Twenty-four-hour ABPM was undertaken in a group of 42 nonagenarians. The 24-h mean, daytime BP, nighttime BP and heart rate (HR) were extracted from the ABPM. Sociodemographic data, the ability to perform basic daily activities, measured by the Barthel index (BI) or instrumental activities revealed by the Lawton and Brody index (LI), cognition, and comorbidity were evaluated. Thirty-one subjects were receiving antihypertensive drug treatment. Twenty-four hour, daytime and sleeping pressures averaged 130/65, 131/68 and 128/63mmHg, respectively. Seventeen (40.5%) of the 42 patients had a daytime BP of 135/85 or higher. In terms of the BP pattern, 8 (19%) subjects were dippers, 19 (45%) non-dippers, and 15 (36%) were risers. Five (45.46%) out of 11 patients with no evidence of hypertension (normotensive patients) had a daytime BP of 135/85 or higher. The mean daytime BP was 135/85 or higher in 12 (38.7%) out of 31 nonagenarians who had previously received therapy for hypertension. In, conclusion a high prevalence of hypertension, misdiagnosis and inadequate BP control was found in nonagenarians treated for hypertension.

  19. Mechanical Properties Experimental Study of Engineering Vehicle Refurbished Tire

    Science.gov (United States)

    Qiang, Wang; Xiaojie, Qi; Zhao, Yang; Yunlong, Wang; Guotian, Wang; Degang, Lv

    2018-05-01

    The vehicle refurbished tire test system was constructed, got load-deformation, load-stiffness, and load-compression ratio property laws of engineering vehicle refurbished tire under the working condition of static state and ground contact, and built radial direction loading deformation mathematics model of 26.5R25 engineering vehicle refurbished tire. The test results show that radial-direction and side-direction deformation value is a little less than that of the new tire. The radial-direction stiffness and compression ratio of engineering vehicle refurbished tire were greatly influenced by radial-direction load and air inflation pressure. When load was certain, radial-direction stiffness would increase with air inflation pressure increasing. When air inflation pressure was certain, compression ratio of engineering vehicle refurbished tire would enlarge with radial-direction load increasing, which was a little less than that of the new and the same type tire. Aging degree of old car-case would exert a great influence on deformation property of engineering vehicle refurbished tire, thus engineering vehicle refurbished tires are suitable to the working condition of low tire pressure and less load.

  20. Chronobiologically Interpreted Ambulatory Blood Pressure Monitoring in Health and Disease.

    Science.gov (United States)

    Halberg, Franz; Mult, Hc; Cornélissen, Germaine; Hillman, Dewayne; Beaty, Larry A; Hong, Shiyu; Schwartzkopff, Othild; Watanabe, Yoshihiko; Otsuka, Kuniaki; Siegelova, Jarmila

    2012-05-01

    To detect vascular variability anomalies (VVAs), a blood pressure and heart rate profile around the clock for at least 7 days is a start. As a minimum, measurement every 60 or preferably 30 minutes for a week is needed, to be continued if abnormality is found, to assess the about 24-hour (circadian) variability that exists in all individuals. As a first dividend, one then also obtains a glimpse of 2 of the very many longer-than-circadian periodicities, the biological half-week and week. Certainly if we can have sensors and computer chips in our cars that continuously monitor the pressure over a tire's life, we should be able to do the same job for ourselves for diagnostic and therapeutic decisions. Healthcare today emphasizes wellness with recommendations for exercise and a proper diet, yet these evaluations may not be adequate. BP may be measured at a visit to the doctor or before an exercise session, along with measuring body weight and performing a physical exam. The seeds of disease are planted long before they are visible, and what appears to be normal from a conventional point of view may in fact actually be abnormal. Hidden alterations of physiological function, masked by the body's remarkable adaptive capabilities, may become visible through a new diagnostic and therapeutic realm-chronobiology-that reveals hitherto unseen abnormalities. The tools of chronobiology may yield additional dividends, such as the detection of physiological "loads" related to stress and stress relief and the undesirable effcts of space weather upon personal events such as sudden cardiac death, societal events like terrorism and war, and natural disasters. Chronobiologi cally interpreted automatic ambulatory BP and heart rate (HR) monitoring (C-ABPM) may detect the antecedents of these types of events. C-ABPM is of interest in preventive cardiology, since it reveals new diagnoses as vascular variability anomalies (VVAs) and renders previous conventional diagnoses more reliable, such

  1. Routine intracranial pressure monitoring in acute coma.

    Science.gov (United States)

    Forsyth, Rob J; Raper, Joseph; Todhunter, Emma

    2015-11-02

    We know that the brain damage resulting from traumatic and other insults is not due solely to the direct consequences of the primary injury. A significant and potentially preventable contribution to the overall morbidity arises from secondary hypoxic-ischaemic damage. Brain swelling accompanied by raised intracranial pressure (ICP) prevents adequate cerebral perfusion with well-oxygenated blood.Detection of raised ICP could be useful in alerting clinicians to the need to improve cerebral perfusion, with consequent reductions in brain injury. To determine whether routine ICP monitoring in severe coma of any cause reduces the risk of all-cause mortality or severe disability at final follow-up. We searched the Cochrane Injuries Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL Plus, ISI Web of Science (SCI-EXPANDED & CPCI-S), clinical trials registries and reference lists. We ran the most recent search on 22 May 2015. All randomised controlled studies of real-time ICP monitoring by invasive or semi-invasive means in acute coma (traumatic or non-traumatic aetiology) versus clinical care without ICP monitoring (that is, guided only by clinical or radiological inference of the presence of raised ICP). Two authors (ET and RF) worked independently to identify the one study that met inclusion criteria. JR and RF independently extracted data and assessed risk of bias. We contacted study authors for additional information, including details of methods and outcome data. One randomized controlled trial (RCT) meeting the selection criteria has been identified to date.The included study had 324 participants. We judged risk of bias to be low for all categories except blinding of participants and personnel, which is not feasible for this intervention. There were few missing data, and we analysed all on an intention-to-treat basis.Participants could be 13 years of age or older (mean age of sample 29

  2. [Ambulatory blood pressure monitoring for hypertension diagnosis?

    Science.gov (United States)

    Gijón Conde, T; Banegas, J R

    2017-01-01

    The early and accurate diagnosis of hypertension is essential given its importance in the development of cardiovascular disease. The boundaries between normal blood pressure (BP) and hypertension are arbitrary and based on the benefits of treating exceeding those of not treating. Conventional BP measurement at the clinic only offers information of a particular time and presents multiple biases dependent on inherent variability of BP and measurement technique itself. Multiple studies have demonstrated the prognosis superiority in the development of cardiovascular disease of ambulatory blood pressure monitoring (ABPM), allows detection of white coat hypertension, avoiding overdiagnosis and overtreatment, and the detection of patients with masked hypertension who are at risk of underdetection and undertreatment. ABPM also assess nightime BP and circadian variability, providing additional prognostic value. ABPM is recognized in the diagnosis of hypertension in 2011 British NICE Guidelines, very argued at the 2013 European Society of Hypertension guidelines, and recommended in the US Preventive Services Task Force in 2015, 2016 Canadian Guidelines and the 2016 Spanish Program of Preventive Activities and Health Promotion (PAPPS). Its generalization is likely to be only a matter of time. Copyright © 2017 Sociedad Española de Hipertension-Liga Española para la Lucha de la Hipertensión Arterial (SEH-LELHA). Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Oxidative desulfurization of tire pyrolysis oil

    OpenAIRE

    Ahmad Shahzad; Ahmad Muhammad Imran; Naeem Khawar; Humayun Muhammad; Sebt-E-Zaeem; Faheem Farrukh

    2016-01-01

    This paper presents a low cost method for the purification of oils obtained from the pyrolysis of used tires. Oxidative desulfurization is a promising route for purification of tire pyrolysis oils as hydro-desulfurization may not be affordable for small scale industries. Different additives and acids have been employed for the enhancement of properties of pyrolytic oils. The experimental conditions were kept identical throughout, i.e. atmospheric pressure a...

  4. Analysis of Tire Contact Parameters Using Visual Processing

    Directory of Open Access Journals (Sweden)

    Valentin Ivanov

    2010-01-01

    The first part of this paper presents the results of experimental estimation of the contact patch area depending on the normal wheel load and inflation pressure for different car tires. The data were obtained for test bench conditions on the basis of the visual processing of tread footprint. Further, the contact length in the cohesion area during wheel rolling for single points on the tire profile has been chosen as a benchmark criterion. This paper has analyzed the influence of the wheel normal load and tire inflation pressure on the contact length with small rolling velocities. The results of the investigations are given for winter and racing tires with different grades of wear.

  5. Vibration Analysis of a Tire in Ground Contact under Varied Conditions

    Directory of Open Access Journals (Sweden)

    Karakus Murat

    2017-03-01

    Full Text Available The effect of three different factors, which are inflation pressure, vertical load and coefficient of friction on the natural frequencies of a tire (175/70 R13 has been studied. A three dimensional tire model is constructed, using four different material properties and parts in the tire. Mechanical properties of the composite parts are evaluated. After investigating the free vibration, contact analysis is carried out. A concrete block and the tire are modelled together, using three different coefficients of friction. Experiments are run under certain conditions to check the accuracy of the numerical model. The natural frequencies are measured to describe free vibration and vibration of the tire contacted by ground, using a damping monitoring method. It is seen, that experimental and numerical results are in good agreement. On the other hand, investigating the impact of three different factors together is quite difficult on the natural frequencies. When some of these factors are assumed to be constant and the variables are taken one by one, it is easier to assess the effects.

  6. Tire Shred Backfill in Mechanically Stabilized Earth Wall Applications

    OpenAIRE

    Balunaini, Umashankar; Yoon, Sungmin; Prezzi, Monica; Salgado, Rodrigo

    2009-01-01

    Tire shred-soil mixture backfill for use in mechanically stabilized earth (MSE) walls has several advantages over traditional backfill materials: 1) good drainage, 2) high shear strength, 3) low compacted unit weight and 4) low lateral pressure exerted on retaining structures. This work presents the results of laboratory tests performed on tire shred-sand mixtures focusing on determining the properties required for their use as backfill in MSE wall applications. Three sizes of tire shreds are...

  7. Ambulatory blood pressure monitoring - comparison with office ...

    African Journals Online (AJOL)

    ambulatory blood pressure recordings in private practice ... position according to established guidelines. ... white-coat effect was defined as a difference of at least 20 .... patients with hypertension: Importance of blood pressure response to ...

  8. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    Science.gov (United States)

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  9. Nonlinear Analysis and Modeling of Tires

    Science.gov (United States)

    Noor, Ahmed K.

    1996-01-01

    The objective of the study was to develop efficient modeling techniques and computational strategies for: (1) predicting the nonlinear response of tires subjected to inflation pressure, mechanical and thermal loads; (2) determining the footprint region, and analyzing the tire pavement contact problem, including the effect of friction; and (3) determining the sensitivity of the tire response (displacements, stresses, strain energy, contact pressures and contact area) to variations in the different material and geometric parameters. Two computational strategies were developed. In the first strategy the tire was modeled by using either a two-dimensional shear flexible mixed shell finite elements or a quasi-three-dimensional solid model. The contact conditions were incorporated into the formulation by using a perturbed Lagrangian approach. A number of model reduction techniques were applied to substantially reduce the number of degrees of freedom used in describing the response outside the contact region. The second strategy exploited the axial symmetry of the undeformed tire, and uses cylindrical coordinates in the development of three-dimensional elements for modeling each of the different parts of the tire cross section. Model reduction techniques are also used with this strategy.

  10. Static tests of constructive tires using hydraulic press on the soil

    OpenAIRE

    Machado,Thiago M.; Lanças,Kléber P.; Oliveira Junior,Mauro B. de; Artioli,José A.; Marasca,Indiamara

    2015-01-01

    ABSTRACT The power consumption and load capacity of agricultural machines have grown and the effects of pressure on the soil by tires have been still little investigated. In concern with sustainable development, the relationship machine-tire-soil must be in balance to give more consistency on the best use of tires for a given load. This study aimed to evaluate four tires of two constructive types, the bias belted tires and radial tires, both with respective rim diameters of 22.5 and 26.5 inch...

  11. Tire safety : everything rides on it

    Science.gov (United States)

    2008-01-01

    This booklet presents a comprehensive overview of tire safety, including information on the following topics: basic tire maintenance; Uniform Tire Quality Grading System; fundamental characteristics of tires; and tire safety tips.

  12. An Analytical Tire Model with Flexible Carcass for Combined Slips

    Directory of Open Access Journals (Sweden)

    Nan Xu

    2014-01-01

    Full Text Available The tire mechanical characteristics under combined cornering and braking/driving situations have significant effects on vehicle directional controls. The objective of this paper is to present an analytical tire model with flexible carcass for combined slip situations, which can describe tire behavior well and can also be used for studying vehicle dynamics. The tire forces and moments come mainly from the shear stress and sliding friction at the tread-road interface. In order to describe complicated tire characteristics and tire-road friction, some key factors are considered in this model: arbitrary pressure distribution; translational, bending, and twisting compliance of the carcass; dynamic friction coefficient; anisotropic stiffness properties. The analytical tire model can describe tire forces and moments accurately under combined slip conditions. Some important properties induced by flexible carcass can also be reflected. The structural parameters of a tire can be identified from tire measurements and the computational results using the analytical model show good agreement with test data.

  13. Expert monitoring and verbal feedback as sources of performance pressure.

    Science.gov (United States)

    Buchanan, John J; Park, Inchon; Chen, Jing; Mehta, Ranjana K; McCulloch, Austin; Rhee, Joohyun; Wright, David L

    2018-05-01

    The influence of monitoring-pressure and verbal feedback on the performance of the intrinsically stable bimanual coordination patterns of in-phase and anti-phase was examined. The two bimanual patterns were produced under three conditions: 1) no-monitoring, 2) monitoring-pressure (viewed by experts), and 3) monitoring-pressure (viewed by experts) combined with verbal feedback emphasizing poor performance. The bimanual patterns were produced at self-paced movement frequencies. Anti-phase coordination was always less stable than in-phase coordination across all three conditions. When performed under conditions 2 and 3, both bimanual patterns were performed with less variability in relative phase across a wide range of self-paced movement frequencies compared to the no-monitoring condition. Thus, monitoring-pressure resulted in performance stabilization rather than degradation and the presence of verbal feedback had no impact on the influence of monitoring pressure. The current findings are inconsistent with the predictions of explicit monitoring theory; however, the findings are consistent with studies that have revealed increased stability for the system's intrinsic dynamics as a result of attentional focus and intentional control. The results are discussed within the contexts of the dynamic pattern theory of coordination, explicit monitoring theory, and action-focused theories as explanations for choking under pressure. Copyright © 2018. Published by Elsevier B.V.

  14. Stereo Vision Inside Tire

    Science.gov (United States)

    2015-08-21

    1 Stereo Vision Inside Tire P.S. Els C.M. Becker University of Pretoria W911NF-14-1-0590 Final...Stereo Vision Inside Tire 5a. CONTRACT NUMBER W911NF-14-1-0590 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Prof PS Els CM...on the development of a stereo vision system that can be mounted inside a rolling tire , known as T2-CAM for Tire -Terrain CAMera. The T2-CAM system

  15. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  16. Evaluation of Tire/Surfacing/Base Contact Stresses and Texture Depth

    Directory of Open Access Journals (Sweden)

    W.J.vdM. Steyn

    2015-03-01

    Full Text Available Tire rolling resistance has a major impact on vehicle fuel consumption. Rolling resistance is the loss of energy due to the interaction between the tire and the pavement surface. This interaction is a complicated combination of stresses and strains which depend on both tire and pavement related factors. These include vehicle speed, vehicle weight, tire material and type, road camber, tire inflation pressure, pavement surfacing texture etc. In this paper the relationship between pavement surface texture depth and tire/surfacing contact stress and area is investigated. Texture depth and tire/surfacing contact stress were measured for a range of tire inflation pressures on five different pavement surfaces. In the analysis the relationship between texture and the generated contact stresses as well as the contact stress between the surfacing and base layer are presented and discussed, and the anticipated effect of these relationships on the rolling resistance of vehicles on the surfacings, and subsequent vehicle fuel economy discussed.

  17. 77 FR 11190 - Yokohama Tire Company, Denial of Petition for Decision of Inconsequential Noncompliance

    Science.gov (United States)

    2012-02-24

    ..., endurance and low inflation pressure performance. The tires also meet all of the physical dimension...-0115; Notice 2] Yokohama Tire Company, Denial of Petition for Decision of Inconsequential Noncompliance...: Yokohama Tire Company (YTC),\\1\\ has determined that certain P215/60R15 93H AVID H4S passenger car...

  18. 75 FR 51524 - Yokohama Tire Corporation, Receipt of Petition for Decision of Inconsequential Noncompliance

    Science.gov (United States)

    2010-08-20

    ... low inflation pressure performance. The tires also meet all of the physical dimension, resistance to...-0115; Notice 1] Yokohama Tire Corporation, Receipt of Petition for Decision of Inconsequential Noncompliance Yokohama Tire Corporation (YTC) \\1\\ has determined that certain P215/60R15 93H AVID H4S passenger...

  19. Intelligent tires for identifying coefficient of friction of tire/road contact surfaces using three-axis accelerometer

    International Nuclear Information System (INIS)

    Matsuzaki, Ryosuke; Kamai, Kazuto; Seki, Ryosuke

    2015-01-01

    Intelligent tires equipped with sensors as well as the monitoring of the tire/road contact conditions are in demand for improving vehicle control and safety. With the aim of identifying the coefficient of friction of tire/road contact surfaces during driving, including during cornering, we develop an identification scheme for the coefficient of friction that involves estimation of the slip angle and applied force by using a single lightweight three-axis accelerometer attached on the inner surface of the tire. To validate the developed scheme, we conduct tire-rolling tests using an accelerometer-equipped tire with various slip angles on various types of road surfaces, including dry and wet surfaces. The results of these tests confirm that the estimated slip angle and applied force are reasonable. Furthermore, the identified coefficient of friction by the developed scheme agreed with that measured by standardized tests. (paper)

  20. Continuous containment monitoring with containment pressure fluctuation

    International Nuclear Information System (INIS)

    Dick, J.E.

    1996-01-01

    The monitoring of the integrity of containments particularly but not exclusively for nuclear plants is dealt with in this invention. While this application is primarily concerned with containment monitoring in the context of the single unit design, it is expected that the concepts presented will be universally applicable to any containment design, including containments for non-nuclear applications such as biological laboratories. The nuclear industry has long been interested in a means of monitoring containment integrity on a continuous basis, that is, while the reactor is operating normally. 12 refs., 2 figs

  1. Materials Approach to Fuel Efficient Tires

    Energy Technology Data Exchange (ETDEWEB)

    Votruba-Drzal, Peter [PPG Industries, Monroeville, PA (United States); Kornish, Brian [PPG Industries, Monroeville, PA (United States)

    2015-06-30

    The objective of this project was to design, develop, and demonstrate fuel efficient and safety regulation compliant tire filler and barrier coating technologies that will improve overall fuel efficiency by at least 2%. The program developed and validated two complementary approaches to improving fuel efficiency through tire improvements. The first technology was a modified silica-based product that is 15% lower in cost and/or enables a 10% improvement in tread wear while maintaining the already demonstrated minimum of 2% improvement in average fuel efficiency. The second technology was a barrier coating with reduced oxygen transmission rate compared to the state-of-the-art halobutyl rubber inner liners that will provide extended placarded tire pressure retention at significantly reduced material usage. A lower-permeance, thinner inner liner coating which retains tire pressure was expected to deliver the additional 2% reduction in fleet fuel consumption. From the 2006 Transportation Research Board Report1, a 10 percent reduction in rolling resistance can reduce consumer fuel expenditures by 1 to 2 percent for typical vehicles. This savings is equivalent to 6 to 12 gallons per year. A 1 psi drop in inflation pressure increases the tire's rolling resistance by about 1.4 percent.

  2. Vibration Analysis of a Tire in Ground Contact under Varied Conditions

    OpenAIRE

    Karakus Murat; Cavus Aydin; Colakoglu Mehmet

    2017-01-01

    The effect of three different factors, which are inflation pressure, vertical load and coefficient of friction on the natural frequencies of a tire (175/70 R13) has been studied. A three dimensional tire model is constructed, using four different material properties and parts in the tire. Mechanical properties of the composite parts are evaluated. After investigating the free vibration, contact analysis is carried out. A concrete block and the tire are modelled together, using three different...

  3. Blood Pressure Home Monitoring in Hypertensive Patients Attending ...

    African Journals Online (AJOL)

    Blood Pressure Home Monitoring in Hypertensive Patients Attending a Tertiary ... Sixty percent of the patients were aged 50 - 69 years. ... Patients with high BP readings reported that they exercise more and reduced their daily salt intake.

  4. Wearable Beat to Beat Blood Pressure Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A key component of NASA's human exploration programs is a system that monitors the health of the crew during space missions. The wearable beat-to-beat blood pressure...

  5. [Ambulatory blood pressure monitoring (ABPM) in elderly].

    Science.gov (United States)

    Palade, D; Iliescu, D; Cotârleţ, Laura; Pandele, G I

    2010-01-01

    Comparison of blood pressure values measured by two methods. 94 hypertensive patients (66 women and 28 men in relation to 2.36/1) were assessed classically and also by ABPM. For statistic evaluation we have used t - Student test, chi2 test, Pearson correlation coefficient and variation coefficient (cv%). It shows significant differences between mean values of systolic and diastolic blood pressure obtained by the 2 methods. ABPM measured values are more accurate compared to clinic, bringing also information on pattern hypertensive therapy.

  6. Loading Deformation Characteristic Simulation Study of Engineering Vehicle Refurbished Tire

    Science.gov (United States)

    Qiang, Wang; Xiaojie, Qi; Zhao, Yang; Yunlong, Wang; Guotian, Wang; Degang, Lv

    2018-05-01

    The paper constructed engineering vehicle refurbished tire computer geometry model, mechanics model, contact model, finite element analysis model, did simulation study on load-deformation property of engineering vehicle refurbished tire by comparing with that of the new and the same type tire, got load-deformation of engineering vehicle refurbished tire under the working condition of static state and ground contact. The analysis result shows that change rules of radial-direction deformation and side-direction deformation of engineering vehicle refurbished tire are close to that of the new tire, radial-direction and side-direction deformation value is a little less than that of the new tire. When air inflation pressure was certain, radial-direction deformation linear rule of engineer vehicle refurbished tire would increase with load adding, however, side-direction deformation showed linear change rule, when air inflation pressure was low; and it would show increase of non-linear change rule, when air inflation pressure was very high.

  7. New developments in tire derived fuels (TDF)

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, G. [Portland Cement Association, Skokie, IL (United States)

    2006-07-01

    Portland cement is a mixture of finely ground raw materials that are processed in a rotary kiln heated to 1500 degrees C by various fuels. Cooled clinker from the kiln is ground into portland cement. This presentation provided an overview of the role that tire-derived fuels is now playing in cement manufacturing. Data on the extent of TDF use in cement manufacturing processes were presented, as well as the results of air emissions monitoring programs conducted to assess the environmental impacts of TDF. During the cement manufacturing process, shredded and chipped tires are blown into the kiln to provide fuel, while whole tires are placed in the midpoint of long dry or wet kilns. For preheater and precalciner kilns, whole tires are added to raw material entering the kiln. The kiln's controlled combustion environment ensures the complete destruction of scrap tires. Approximately 130 million scrap tires were recycled in Portland cement plants in 2003. Forty-four portland cement plants are currently using TDF in North America. The United States Department of Energy has estimated that TDF produces less carbon dioxide (CO{sub 2}) per unit of energy than coal. Monitoring programs at Portland cement plants have indicated that the use of TDF in place of coal has resulted in moderate reductions of nitrogen oxide (NO{sub x}) emissions, slightly lower sulfuric oxide (SO{sub 2}) emissions and moderate reductions in carbon monoxide (CO). Some plants have reported slight reductions in particulate matter (PM) emissions. It was concluded that the use of scrap tires as a fuel reduces a waste stream and contributes to energy and raw material requirements. Moreover, plant air emissions are either reduced or are not impacted by TDF use. refs., tabs., figs.

  8. Measuring sub-bandage pressure: comparing the use of pressure monitors and pulse oximeters.

    Science.gov (United States)

    Satpathy, A; Hayes, S; Dodds, S R

    2006-03-01

    To test the use of low-cost sub-bandage pressure monitors and pulse oximeters as part of a quality-control measure for graduated compression bandaging in leg ulcer clinics. Twenty-five healthy volunteers (mean age 40 years) providing 50 limbs were bandaged with a four-layer compression bandaging system. The ankle systolic pressure (ASP) was measured using a pulse oximeter (Nellcor NBP-40) before applying the graduated compression bandages. Interface pressure was measured by placing pressure sensors on the skin at three points (2cm above the medial malleolus; the widest part of the calf; and a point midway between them) in the supine and standing positions. The ASP was measured again with the pulse oximeter after the bandage had been applied, and the effect of the bandage on the ASP was recorded. The actual pressure created by the bandage was compared with the required pressure profile. Interface pressures varied with change of position and movement. With the operator blinded to the pressure monitors while applying the bandages, the target pressure of 35-40mmHg at the ankle was achieved in only 36% of limbs ([mean +/- 95% confidence interval]; 32.3 +/- 1.6mmHg [supine]; 38.4 +/- 2.4mmHg [standing position]). With the help of the pressure monitors, the target pressure was achieved in 78% of the limbs. There was no correlation between the pressure monitors and pulse oximeter pressures, demonstrating that the pulse oximeter is not a useful tool for measuring sub-bandage pressures. The results suggest a tool (interface pressure monitors) that is easy to operate should be available as part of quality assurance for treatment, training of care providers and education.

  9. Microwave Absorption Characteristics of Tire

    Science.gov (United States)

    Zhang, Yuzhe; Hwang, Jiann-Yang; Peng, Zhiwei; Andriese, Matthew; Li, Bowen; Huang, Xiaodi; Wang, Xinli

    The recycling of waste tires has been a big environmental problem. About 280 million waste tires are produced annually in the United States and more than 2 billion tires are stockpiled, which cause fire hazards and health issues. Tire rubbers are insoluble elastic high polymer materials. They are not biodegradable and may take hundreds of years to decompose in the natural environment. Microwave irradiation can be a thermal processing method for the decomposition of tire rubbers. In this study, the microwave absorption properties of waste tire at various temperatures are characterized to determine the conditions favorable for the microwave heating of waste tires.

  10. Design and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention

    Directory of Open Access Journals (Sweden)

    Farve Daneshvar Fard

    2014-08-01

    Full Text Available Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer prevention. Materials and Methods The monitoring system consists of 64 pressure and 64 temperature sensors on a 40×50 cm2 sheet. Pressure and temperature data and the corresponding maps were displayed on a computer in real-time. Risk assessment could be performed by monitoring and recording absolute pressure and temperature values, as well as deviations over time. Furthermore, a posture detection procedure was proposed for sitting posture identification. Information about the patient’s movement history may help caregivers make informed decisions about the patient’s repositioning and ulcer prevention strategies. Results Steady temporal behaviour of the designed system and repeatability of the measurements were evaluated using several particular tests. The results illustrated that the system could be utilized for continuous monitoring of interface pressure and temperature for pressure ulcer prevention. Furthermore, the proposed method for detecting sitting posture was verified using a statistical analysis. Conclusion A continuous time pressure and temperature monitoring system was presented in this study. This system may be suited for pressure ulcer prevention given its feasibility for simultaneous monitoring of pressure and temperature and alarming options. Furthermore, a method for detecting different sitting postures was proposed and verified. Pressure ulcers in wheelchair-bound patients may be prevented using this sitting posture detection method.

  11. A Strain-Based Method to Detect Tires' Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development.

    Science.gov (United States)

    Yunta, Jorge; Garcia-Pozuelo, Daniel; Diaz, Vicente; Olatunbosun, Oluremi

    2018-02-06

    Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire's loss of grip and estimations of the lateral friction coefficient.

  12. Cuff inflation during ambulatory blood pressure monitoring and heart rate

    Directory of Open Access Journals (Sweden)

    Mia Skov-Madsen

    2008-11-01

    Full Text Available Mia Skov-Madsen, My Svensson, Jeppe Hagstrup ChristensenDepartment of Nephrology, Aarhus University Hospital, Aalborg, DenmarkIntroduction: Twenty four-hour ambulatory blood pressure monitoring is a clinically validated procedure in evaluation of blood pressure (BP. We hypothesised that the discomfort during cuff inflation would increase the heart rate (HR measured with 24-h ambulatory BP monitoring compared to a following HR measurement with a 24-h Holter monitor.Methods: The study population (n = 56 were recruited from the outpatient’s clinic at the Department of Nephrology, Aalborg Hospital, Aarhus University Hospital at Aalborg, Denmark. All the patients had chronic kidney disease (CKD. We compared HR measured with a 24-h Holter monitor with a following HR measured by a 24-h ambulatory BP monitoring.Results: We found a highly significant correlation between the HR measured with the Holter monitor and HR measured with 24-h ambulatory blood pressure monitoring (r = 0.77, p < 0.001. Using the Bland-Altman plot, the mean difference in HR was only 0.5 beat/min during 24 hours with acceptable limits of agreement for both high and low HR levels. Dividing the patients into groups according to betablocker treatment, body mass index, age, sex, angiotensin-converting enzyme inhibitor treatment, statins treatment, diuretic treatment, or calcium channel blocker treatment revealed similar results as described above.Conclusion: The results indicate that the discomfort induced by cuff inflation during 24-h ambulatory BP monitoring does not increase HR. Thus, 24-h ambulatory BP monitoring may be a reliable measurement of the BP among people with CKD.Keywords: ambulatory blood pressure monitoring, Holter monitoring, heart rate, chronic kidney disease, hypertension

  13. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  14. An ultralow power wireless intraocular pressure monitoring system

    International Nuclear Information System (INIS)

    Liu Demeng; Mei Niansong; Zhang Zhaofeng

    2014-01-01

    This paper describes an ultralow power wireless intraocular pressure (IOP) monitoring system that is dedicated to sensing and transferring intraocular pressure of glaucoma patients. Our system is comprised of a capacitive pressure sensor, an application-specific integrated circuit, which is designed on the SMIC 180 nm process, and a dipole antenna. The system is wirelessly powered and demonstrates a power consumption of 7.56 μW at 1.24 V during continuous monitoring, a significant reduction in active power dissipation compared to existing work. The input RF sensitivity is −13 dBm. A significant reduction in input RF sensitivity results from the reduction of mismatch time of the ASK modulation caused by FM0 encoding. The system exhibits an average error of ± 1.5 mmHg in measured pressure. Finally, a complete IOP system is demonstrated in the real biological environment, showing a successful reading of the pressure of an eye. (semiconductor integrated circuits)

  15. Acoustic emission monitoring of a pressure vessel

    International Nuclear Information System (INIS)

    Birchon, D.; Dukes, R.; Taylor, J.

    1975-01-01

    Results of some defect location studies on a pressure vessel are reported and correlated with those of ultrasonic inspection. Good agreement was observed, with a probability greater than 90% that a defect location detected would be confirmed by ultrasonics. This good agreement is considered to result from the use of peak sensing rather than the more commonly used leading edge triggering technique. Attention is drawn to the influence of the defect extension process upon the ease of detection, contrasting the difficulty of detecting slow crack growth with the ease of detection of pulses originating from the fracture of hard particles or their separation from the matrix, and to the influence of the Kaiser effect, which can mean that a flaw may not be detectable unless previously applied stress levels are exceeded, or that flaw growth has occurred since the previous inspection, or that some metallurgical recovery process has operated. (author)

  16. Studless Winter Tires

    Science.gov (United States)

    1976-01-01

    Goodyear Tire and Rubber Company developed a material for Johnson Space Center used as parachute shrouds to soft land the Vikings through the tenuous Martian atmosphere and has been adapted to new radial tire five times stronger than steel. Fiber has a chain-like molecular structure that gives it incredible strength in proportion to its weight. Material is expected to increase tread life by 10,000 miles.

  17. Photocatalytic Desulfurization of Waste Tire Pyrolysis Oil

    Directory of Open Access Journals (Sweden)

    Napida Hinchiranan

    2011-11-01

    Full Text Available Waste tire pyrolysis oil has high potential to replace conventional fossil liquid fuels due to its high calorific heating value. However, the large amounts of sulfurous compounds in this oil hinders its application. Thus, the aim of this research was to investigate the possibility to apply the photo-assisted oxidation catalyzed by titanium dioxide (TiO2, Degussa P-25 to partially remove sulfurous compounds in the waste tire pyrolysis oil under milder reaction conditions without hydrogen consumption. A waste tire pyrolysis oil with 0.84% (w/w of sulfurous content containing suspended TiO2 was irradiated by using a high-pressure mercury lamp for 7 h. The oxidized sulfur compounds were then migrated into the solvent-extraction phase. A maximum % sulfur removal of 43.6% was achieved when 7 g/L of TiO2 was loaded into a 1/4 (v/v mixture of pyrolysis waste tire oil/acetonitrile at 50 °C in the presence of air. Chromatographic analysis confirmed that the photo-oxidized sulfurous compounds presented in the waste tire pyrolysis oil had higher polarity, which were readily dissolved and separated in distilled water. The properties of the photoxidized product were also reported and compared to those of crude oil.

  18. Self-monitored blood pressure: a role in clinical practice?

    Science.gov (United States)

    Padfield, Paul L

    2002-02-01

    Electronic self-monitoring of blood pressure is increasing in popularity and most international guidelines on the management of hypertension approve cautious use of the technique in the assessment of potentially hypertensive individuals. A recent editorial in the Archives of Internal Medicine suggested that it was "appropriate to encourage the widespread use of self recorded BP as an important adjunct to the clinical care of the patient with hypertension". Such a statement is based on increasing evidence that self-monitoring of blood pressure gives similar information to daytime ambulatory blood pressure -- a now well-established technology in the management of hypertension. Suggested strategies for the use of self-monitoring of blood pressure include monitoring in individuals whose clinical risk status is low enough that they need not necessarily be given medical therapy simply on the basis of a clinic pressure (i.e. at a 10 year risk of cardiovascular disease below 20%). The threshold for defining 'normotension/hypertension' is now regarded as being broadly similar for ABPM and SBPM and is set at 135/85 mmHg. In a recent meta-analysis of all available studies the average difference between these techniques, using the same patients, is -1.7/1.2 mmHg. There is some evidence that careful use of self-monitoring may improve blood pressure control in patients who are otherwise resistant to care. Self-monitoring of blood pressure has now been shown in at least one major prospective study to predict outcome better than clinic pressures and in that setting it now has equivalence to the use of ABPM. There remain issues regarding the availability of validated devices, the quality of training of patients in their use and the possibility that inaccurate recording might occur, either deliberately or by accident. Self-monitoring of blood pressure may well not give the same readings as carefully measured blood pressure by research nurses but its use is clearly superior to

  19. Preliminary measurements on heat balance in pneumatic tires

    Science.gov (United States)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  20. Evaluation of substitution monopole models for tire noise sound synthesis

    Science.gov (United States)

    Berckmans, D.; Kindt, P.; Sas, P.; Desmet, W.

    2010-01-01

    Due to the considerable efforts in engine noise reduction, tire noise has become one of the major sources of passenger car noise nowadays and the demand for accurate prediction models is high. A rolling tire is therefore experimentally characterized by means of the substitution monopole technique, suiting a general sound synthesis approach with a focus on perceived sound quality. The running tire is substituted by a monopole distribution covering the static tire. All monopoles have mutual phase relationships and a well-defined volume velocity distribution which is derived by means of the airborne source quantification technique; i.e. by combining static transfer function measurements with operating indicator pressure measurements close to the rolling tire. Models with varying numbers/locations of monopoles are discussed and the application of different regularization techniques is evaluated.

  1. Leaching of DOC, DN, and inorganic constituents from scrap tires.

    Science.gov (United States)

    Selbes, Meric; Yilmaz, Ozge; Khan, Abdul A; Karanfil, Tanju

    2015-11-01

    One concern for recycle and reuse of scrap tires is the leaching of tire constituents (organic and inorganic) with time, and their subsequent potential harmful impacts in environment. The main objective of this study was to examine the leaching of dissolved organic carbon (DOC), dissolved nitrogen (DN), and selected inorganic constituents from scrap tires. Different sizes of tire chips and crumb rubber were exposed to leaching solutions with pH's ranging from 3.0 to 10.0 for 28days. The leaching of DOC and DN were found to be higher for smaller size tire chips; however, the leaching of inorganic constituents was independent of the size. In general, basic pH conditions increased the leaching of DOC and DN, whereas acidic pH conditions led to elevated concentrations of metals. Leaching was minimal around the neutral pH values for all the monitored parameters. Analysis of the leaching rates showed that components associated with the rubbery portion of the tires (DOC, DN, zinc, calcium, magnesium, etc.) exhibited an initial rapid followed by a slow release. On the other hand, a constant rate of leaching was observed for iron and manganese, which are attributed to the metal wires present inside the tires. Although the total amounts that leached varied, the observed leaching rates were similar for all tire chip sizes and leaching solutions. Operation under neutral pH conditions, use of larger size tire chips, prewashing of tires, and removal of metal wires prior to application will reduce the impact of tire recycle and reuse. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Acoustic Emission for on-line reactor pressure boundary monitoring

    International Nuclear Information System (INIS)

    Hutton, P.H.; Kurtz, R.J.; Pappas, R.A.

    1985-01-01

    The program objective is to develop AE for continuous surveillance to assess flaw growth in reactor pressure boundaries. Technology in the laboratory is being evaluated on structures. Results have demonstrated basic feasibility of the program objective. AE monitoring a long term fatigue test of a pressure vessel demonstrated an instrument system, and the ability to detect unexpected as well as well as known fatigue cracks. Monitoring a nuclear reactor system shows that the coolant flow noise problem is manageable and AE can be detected under simulated operating conditions

  3. Use of intracranial pressure monitoring in bacterial meningitis

    DEFF Research Database (Denmark)

    Larsen, Lykke; Rom Poulsen, Frantz; Nielsen, Troels H

    2017-01-01

    BACKGROUND: The aim of this study was to evaluate the clinical outcome of patients with severe bacterial meningitis where intracranial pressure (ICP) monitoring has been performed. METHODS: A retrospective observational study including patients admitted 1st(.) January 2005 to 31st(.) December 2014...... CT scans with signs of elevated ICP. CONCLUSIONS: Patients with severe meningitis should be admitted to intensive care units and evaluated for ICP monitoring regardless of head CT findings....

  4. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  5. Development of optoelectronic monitoring system for ear arterial pressure waveforms

    Science.gov (United States)

    Sasayama, Satoshi; Imachi, Yu; Yagi, Tamotsu; Imachi, Kou; Ono, Toshirou; Man-i, Masando

    1994-02-01

    Invasive intra-arterial blood pressure measurement is the most accurate method but not practical if the subject is in motion. The apparatus developed by Wesseling et al., based on a volume-clamp method of Penaz (Finapres), is able to monitor continuous finger arterial pressure waveforms noninvasively. The limitation of Finapres is the difficulty in measuring the pressure of a subject during work that involves finger or arm action. Because the Finapres detector is attached to subject's finger, the measurements are affected by inertia of blood and hydrostatic effect cause by arm or finger motion. To overcome this problem, the authors made a detector that is attached to subject's ear and developed and optoelectronic monitoring systems for ear arterial pressure waveform (Earpres). An IR LEDs, photodiode, and air cuff comprised the detector. The detector was attached to a subject's ear, and the space adjusted between the air cuff and the rubber plate on which the LED and photodiode were positioned. To evaluate the accuracy of Earpres, the following tests were conducted with participation of 10 healthy male volunteers. The subjects rested for about five minutes, then performed standing and squatting exercises to provide wide ranges of systolic and diastolic arterial pressure. Intra- and inter-individual standard errors were calculated according to the method of van Egmond et al. As a result, average, the averages of intra-individual standard errors for earpres appeared small (3.7 and 2.7 mmHg for systolic and diastolic pressure respectively). The inter-individual standard errors for Earpres were about the same was Finapres for both systolic and diastolic pressure. The results showed the ear monitor was reliable in measuring arterial blood pressure waveforms and might be applicable to various fields such as sports medicine and ergonomics.

  6. Ambulatory blood pressure monitoring in clinical trials with antihypertensive agents

    NARCIS (Netherlands)

    A.H. van den Meiracker (Anton)

    1995-01-01

    textabstractAmbulatory blood pressure monitoring (ABPM) is being used increasingly for the evaluation of antihypertensive agents in clinical trials. In this brief review several aspects of ABPM are discussed. In particular, attention is paid to the extent to which ABPM is subject to a placebo

  7. Patient Blood Pressure and Pulse Rate Monitoring With an Alert ...

    African Journals Online (AJOL)

    2012-12-01

    Dec 1, 2012 ... an Alert System Using the Omron 790it Blood Pressure. Monitor ... detailed medical information on the vital signs of patients and will save many lives that may be lost. Keywords: Omron .... at rest, in beats per minute (BPM):.

  8. Monitoring operational conditions of vehicle tyre pressure levels and ...

    African Journals Online (AJOL)

    Compliance with vehicle tyre inflation pressure and tread depth standard specifications and legal requirements were monitored by survey study in Kumasi Metropolis, Ghana. The survey covered 400 vehicles, comprising cars (28 %), medium buses (25 %), large capacity buses (15 %) and trucks (32 %). There were wide ...

  9. Home monitoring of blood pressure: patients' perception and role of ...

    African Journals Online (AJOL)

    Purpose: To explore the use of the blood pressure monitors by hypertensive patients in Jordanian homes and investigate their effect on emotional status and disease management, and the role of the pharmacist in this regard. Methods: This cross-sectional study was conducted over two months in 2012, in Amman, Jordan.

  10. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  11. Glucose Monitoring System Based on Osmotic Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Alexandra LEAL

    2011-02-01

    Full Text Available This paper presents the design and development of a prototype sensor unit for implementation in a long-term glucose monitoring system suitable for estimating glucose levels in people suffering from diabetes mellitus. The system utilizes osmotic pressure as the sensing mechanism and consists of a sensor prototype that is integrated together with a pre-amplifier and data acquisition unit for both data recording and processing. The sensor prototype is based on an embedded silicon absolute pressure transducer and a semipermeable nanoporous membrane that is enclosed in the sensor housing. The glucose monitoring system facilitates the integration of a low power microcontroller that is combined with a wireless inductive powered communication link. Experimental verification have proven that the system is capable of tracking osmotic pressure changes using albumin as a model compound, and thereby show a proof of concept for novel long term tracking of blood glucose from remote sensor nodes.

  12. The influence of the tire inflation on pull properties of agriculture tractors

    Directory of Open Access Journals (Sweden)

    Jakub Katrenčík

    2013-01-01

    Full Text Available Agricultural tractors are robust and versatile machines, which must comply with the basic requirements of users under various conditions. The main requirements include economical and reliable operation and high performance. Fuel economy could be improved using multiple methods, for example a well trained operator, adequate farming conditions and optimal tire inflation. Tractor tires transmit engine power to the surface and as such they are crucial to tractor operation. In the first part of the field measurement, all tires were inflated to 180kPa, while in the second part of the field measurements the tire pressure was set to 75kPa in front tires and to 65 kPa in rear tires. The results of the field measurement of the John Deere 6920S tractor with different tire inflation shows that pull performance increased by 9.9% and wheel slip decreased by 9.7%.

  13. Online Monitoring of Composite Overwrapped Pressure Vessels (COPV)

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; Figueiredo, Joana; Faria, Hugo

    2015-01-01

    product development, design and optimization, as well as to minimize the risks and improve the public acceptance. Within the scope of developing different COPV models for a wide range of operating pressures and applications, optical fiber Bragg grating (FBG) sensors were embedded in the liner......Composite overwrapped pressure vessels (COPV) have been increasingly pointed to as the most effective solution for high pressure storage of liquid and gaseous fluids. Reasonably high stiffness-to-weight ratios make them suitable for both static and mobile applications. However, higher operating...... pressures are sought continuously, to get higher energy densities in such storage systems, and safety aspects become critical. Thus, reliable design and test procedures are required to reduce the risks of undesired and unpredicted failures. An in-service health monitoring system may contribute to a better...

  14. Monitoring of deposits in pipelines using pressure pulse technology

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, Jon S.; Celius, Harald K.

    2005-07-01

    The basis of pressure pulse technology is presented in terms of the water hammer equation, the pipeline pressure drop equation and the equation for speed of sound in multiphase mixtures. The technology can be used for a range of applications, from on-line monitoring of flowing conditions to on-demand measurements and analysis to locate and quantify deposits in wells and pipelines. While pressure pulse measurements are low-cost and easy to implement, the commercial use of pressure pulse technology has resulted from extensive field experience and substantial in-house software development. Simulation tools were used to illustrate the effect of a 2 mm thick deposit, 500 m long and located 375 m from a quick-acting valve. The simulation conditions used are typical for multiphase gas-oil flow along a horizontal 2 km long pipeline from wellhead to manifold. (Author)

  15. Ambulatory blood pressure and adherence monitoring: diagnosing pseudoresistant hypertension.

    Science.gov (United States)

    Burnier, Michel; Wuerzner, Gregoire

    2014-01-01

    A small proportion of the treated hypertensive population consistently has a blood pressure greater than 140/90 mm Hg despite a triple therapy including a diuretic, a calcium channel blocker, and a blocker of the renin-angiotensin system. According to guidelines, these patients have so-called resistant hypertension. The prevalence of this clinical condition is higher in tertiary than primary care centers and often is associated with chronic kidney disease, diabetes, obesity, and sleep apnea syndrome. Exclusion of pseudoresistant hypertension using ambulatory or home blood pressure monitoring is a crucial step in the investigation of patients with resistant hypertension. Thus, among the multiple factors to consider when investigating patients with resistant hypertension, ambulatory blood pressure monitoring should be performed very early. Among other factors to consider, physicians should investigate patient adherence to therapy, assess the adequacy of treatment, exclude interfering factors, and, finally, look for secondary forms of hypertension. Poor adherence to therapy accounts for 30% to 50% of cases of resistance to therapy depending on the methodology used to diagnose adherence problems. This review discusses the clinical factors implicated in the pathogenesis of resistant hypertension with a particular emphasis on pseudoresistance, drug adherence, and the use of ambulatory blood pressure monitoring for the diagnosis and management of resistant hypertension.

  16. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  17. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    Science.gov (United States)

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.

  18. Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure.

    Science.gov (United States)

    Frischholz, M; Sarmento, L; Wenzel, M; Aquilina, K; Edwards, R; Coakham, H B

    2007-01-01

    Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high.

  19. Pressure mapping with textile sensors for compression therapy monitoring.

    Science.gov (United States)

    Baldoli, Ilaria; Mazzocchi, Tommaso; Paoletti, Clara; Ricotti, Leonardo; Salvo, Pietro; Dini, Valentina; Laschi, Cecilia; Francesco, Fabio Di; Menciassi, Arianna

    2016-08-01

    Compression therapy is the cornerstone of treatment in the case of venous leg ulcers. The therapy outcome is strictly dependent on the pressure distribution produced by bandages along the lower limb length. To date, pressure monitoring has been carried out using sensors that present considerable drawbacks, such as single point instead of distributed sensing, no shape conformability, bulkiness and constraints on patient's movements. In this work, matrix textile sensing technologies were explored in terms of their ability to measure the sub-bandage pressure with a suitable temporal and spatial resolution. A multilayered textile matrix based on a piezoresistive sensing principle was developed, calibrated and tested with human subjects, with the aim of assessing real-time distributed pressure sensing at the skin/bandage interface. Experimental tests were carried out on three healthy volunteers, using two different bandage types, from among those most commonly used. Such tests allowed the trends of pressure distribution to be evaluated over time, both at rest and during daily life activities. Results revealed that the proposed device enables the dynamic assessment of compression mapping, with a suitable spatial and temporal resolution (20 mm and 10 Hz, respectively). In addition, the sensor is flexible and conformable, thus well accepted by the patient. Overall, this study demonstrates the adequacy of the proposed piezoresistive textile sensor for the real-time monitoring of bandage-based therapeutic treatments. © IMechE 2016.

  20. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  1. Ambulatory blood pressure monitoring for hypertension in general practice.

    OpenAIRE

    Taylor, R S; Stockman, J; Kernick, D; Reinhold, D; Shore, A C; Tooke, J E

    1998-01-01

    Ambulatory blood pressure monitoring (ABPM) is being increasingly used in general practice. There is at present little published evidence regarding the clinical utility of ABPM in the care of patients with established hypertension in this setting. We examined this issue by undertaking ABPM in a group of patients with established hypertension. 40 patients (aged 33-60 years) currently being treated for hypertension were randomly selected from a general practice list and underwent a single 24-ho...

  2. Subharmonic Imaging and Pressure Estimation for Monitoring Neoadjuvant Chemotherapy

    Science.gov (United States)

    2015-11-01

    the acoustic output power for SHAPE has been developed on the scanner. Briefly, the optimization algorithm steps the ultrasound scanner from 0 to... ultrasound contrast agents to improve the monitoring of breast cancer treatment response to neoadjuvant therapies in women diagnosed with LABC by imaging...estimation (SHAPE). Software for analyzing RF data from a Logiq 9 ultrasound scanner (GE Healthcare, Milwauke, WI) to produce 3D SHAPE pressure

  3. Numerical Study of Tire Hydroplaning Based on Power Spectrum of Asphalt Pavement and Kinetic Friction Coefficient

    Directory of Open Access Journals (Sweden)

    Shengze Zhu

    2017-01-01

    Full Text Available Hydroplaning is a driving phenomenon threating vehicle’s control stability and safety. It happens when tire rolls on wet pavement with high speed that hydrodynamic force uplifts the tire. Accurate numerical simulation to reveal the mechanism of hydroplaning and evaluate the function of relevant factors in this process is significant. In order to describe the friction behaviors of tire-pavement interaction, kinetic friction coefficient curve of tire rubber and asphalt pavement was obtained by combining pavement surface power spectrum and complex modulus of tread rubber through Persson’s friction theory. Finite element model of tire-fluid-pavement was established in ABAQUS, which was composed of a 225-40-R18 radial tire and three types of asphalt pavement covered with water film. Mechanical responses and physical behaviors of tire-pavement interaction were observed and compared with NASA equation to validate the applicability and accuracy of this model. Then contact force at tire-pavement interface and critical hydroplaning speed influenced by tire inflation pressure, water film thickness, and pavement types were investigated. The results show higher tire inflation pressure, thinner water film, and more abundant macrotexture enhancing hydroplaning speed. The results could be applied to predict hydroplaning speed on different asphalt pavement and improve pavement skid resistance design.

  4. Pressure cycling monitoring helps ensure the integrity of energy pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Song, Peter; Lawrence, Doug; Keane, Sean; Ironside, Scott; Sutton, Aaron [Enbridge Pipelines Inc., Edmonton, AB (Canada)

    2010-07-01

    Enbridge Pipelines Inc. undertook a pressure cycling monitoring (PCM) program to see how pressure cycling severity (PCS) changes during line operations. The main purpose of this program is to make sure the integrity assessment interval is valid and to identify changes in operations that cause fatigue damage. The estimated fatigue life is obtained through fatigue analysis, which is based on Paris Law and uses certain data such as the operating pressure data from Enbridge's SCADA system. It serves as a measure of the PCS. When applied in an integrity management program, PCM helps maintain the integrity of pipelines by pinpointing segments whose operations have changed significantly. Among useful conclusions, it was found that a comparison between crack threat susceptibility indicators and PCS fluctuations help identify a change to crack threat susceptibility; also, the program helps identify notable changes to PCS that are caused by certain operational practices.

  5. Review on pressure sensors for structural health monitoring

    Science.gov (United States)

    Sikarwar, Samiksha; Satyendra; Singh, Shakti; Yadav, Bal Chandra

    2017-12-01

    This paper reports the state of art in a variety of pressure and the detailed study of various matrix based pressure sensors. The performances of the bridges, buildings, etc. are threatened by earthquakes, material degradations, and other environmental effects. Structural health monitoring (SHM) is crucial to protect the people and also for assets planning. This study is a contribution in developing the knowledge about self-sensing smart materials and structures for the construction industry. It deals with the study of self-sensing as well as mechanical and electrical properties of different matrices based on pressure sensors. The relationships among the compression, tensile strain, and crack length with electrical resistance change are also reviewed.

  6. SIMULATION AND INVESTIGATION OF TIRE TREAD BLOCKS INTERACTION WITH ICE

    Directory of Open Access Journals (Sweden)

    Andrius Ružinskas

    2017-12-01

    Full Text Available The car tire is an essential subject analysing its interaction with the road. From tire’s tread condition, geometry and rubber compound depends grip and vehicle stability. This is especially relevant in winter time, when roads are covered with the layer of snow or ice. Generally, new tires are tested in real traffic conditions using vehicles. However, ensuring these conditions requires many resources and sometimes it could be a big challenge. For this reason, simulation of the tire interaction with the road becomes more important in nowadays tire researches. Since the tire is a complex engineering subject, the tire tread blocks could be separated for individual analysis. The interaction between the dry ice and the tread block with sipes was analysed using finite element analysis. The tread block was described using hyperelastic Mooney­Rivlin material model. The deformations, distribution of the contact pressure and shear stresses were obtained for the soft and hard rubber compounds with different vertical load conditions. Also a solid tread block interaction was analysed and it was found that values of contact pressure and shear stresses are much lower comparing to siped tread block.

  7. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

    Science.gov (United States)

    Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel

    2009-06-01

    Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

  8. An assessment of acoustic emission for nuclear pressure vessel monitoring

    International Nuclear Information System (INIS)

    Scruby, C.B.

    1983-01-01

    Recent research has greatly improved our understanding of the basic mechanisms of deformation and fracture that generate detectable acoustic emission signals in structural steels. A critical review of the application of acoustic emission (AE) to the fabrication, proof testing and in-service monitoring of nuclear pressure vessels is presented in the light of this improved understanding. The detectability of deformation and fracture processes in pressure vessel steels is discussed, and recommendations made for improving source location accuracy and the development of quantitative source assessment techniques. Published data suggest that AE can make an important contribution to fabrication monitoring, and to the detection of defects in lower toughness materials during vessel proof testing. In high toughness materials, however, the signals generated during ductile crack growth may frequently be too weak for reliable detection. The feasibility of AE for continuous monitoring has not yet been adequately demonstrated because of high background noise levels and uncertainty about AE signal strengths from the defect growth processes that occur in service. In-service leak detection by AE shows considerable promise. It is recommended that further tests are carried out with realistic defects, and under realistic conditions of loading (including thermal shock and fatigue) and of environment. (author)

  9. Tire deflation device

    Science.gov (United States)

    Barker, Stacey G [Idaho Falls, ID

    2010-01-05

    A tire deflation device includes (1) a component having a plurality of bores, (2) a plurality of spikes removably insertable into the plurality of bores and (3) a keeper within each among the plurality of bores, the keeper being configured to contact a sidewall surface of a spike among the plurality of spikes and to exert force upon the sidewall surface. In an embodiment, the tire deflation device includes (a) a component including a bore in a material, the bore including a receiving region, a sidewall surface and a base surface, (b) a channel extending from the sidewall surface into the material, (c) a keeper having a first section housed within the channel and a second section which extends past the sidewall surface into the receiving region, and (d) a spike removably insertable into the bore.

  10. A Novel Strain-Based Method to Estimate Tire Conditions Using Fuzzy Logic for Intelligent Tires

    Directory of Open Access Journals (Sweden)

    Daniel Garcia-Pozuelo

    2017-02-01

    Full Text Available The so-called intelligent tires are one of the most promising research fields for automotive engineers. These tires are equipped with sensors which provide information about vehicle dynamics. Up to now, the commercial intelligent tires only provide information about inflation pressure and their contribution to stability control systems is currently very limited. Nowadays one of the major problems for intelligent tire development is how to embed feasible and low cost sensors to obtain reliable information such as inflation pressure, vertical load or rolling speed. These parameters provide key information for vehicle dynamics characterization. In this paper, we propose a novel algorithm based on fuzzy logic to estimate the mentioned parameters by means of a single strain-based system. Experimental tests have been carried out in order to prove the suitability and durability of the proposed on-board strain sensor system, as well as its low cost advantages, and the accuracy of the obtained estimations by means of fuzzy logic.

  11. Michelin tire baby syndrome

    Directory of Open Access Journals (Sweden)

    Rita V Vora

    2016-01-01

    Full Text Available Michelin tire baby syndrome (MTBS, is a rare genodermatosis, characterized by generalized folding of excess skin and may be associated with various phenotypic abnormalities. The pathogenesis of this condition is unclear. Various congenital anomalies can be associated with it. It may be a clinical finding associated with various syndromes. Diagnosis is mainly clinical, and skin folds gradually diminish and disappear with age without any intervention. Here, we report a case of MTBS associated with convergent squint and hydrocephaly.

  12. Construction of a test embankment using a sand-tire shred mixture as fill material.

    Science.gov (United States)

    Yoon, Sungmin; Prezzi, Monica; Siddiki, Nayyar Zia; Kim, Bumjoo

    2006-01-01

    Use of tire shreds in construction projects, such as highway embankments, is becoming an accepted way of beneficially recycling scrap tires. However, in the last decade there was a decline in the use of pure tire shreds as fill materials in embankment construction, as they are susceptible to fire hazards due to the development of exothermic reactions. Tire shred-sand mixtures, on the other hand, were found to be effective in inhibiting exothermic reactions. When compared with pure tire shreds, tire shred-sand mixtures are less compressible and have higher shear strength. However, the literature contains limited information on the use of tire shred-soil mixtures as a fill material. The objectives of this paper are to discuss and evaluate the feasibility of using tire shred-sand mixtures as a fill material in embankment construction. A test embankment constructed using a 50/50 mixture, by volume, of tire shreds and sand was instrumented and monitored to: (a) determine total and differential settlements; (b) evaluate the environmental impact of the embankment construction on the groundwater quality due to leaching of fill material; and (c) study the temperature variation inside the embankment. The findings in this research indicate that mixtures of tire shreds and sand are viable materials for embankment construction.

  13. Ambulatory Blood Pressure Monitoring – Clinical Practice Recommendations

    Directory of Open Access Journals (Sweden)

    Katalin Mako

    2016-09-01

    Full Text Available Ambulatory blood pressure monitoring (ABPM became a subject of considerable scientific interest. Due to the increasing use of the ABPM in everyday clinical practice it is important that all the users have a correct knowledge on the clinical indications, the methodology of using the device including some technical issues and the interpretation of results. In the last years several guidelines and position papers have been published with recommendations for the monitoring process, reference values, for clinical practice and research. This paper represents a summary of the most important aspects related to the use of ABPM in daily practice, being a synthesis of recommendations from the recent published guidelines and position papers. This reference article presents the practical and technical issues of ABPM, the use of this method in special situations, the clinical interpretation of measured values including the presentation of different ABPM patterns, derived parameters, the prognostic significance and the limitations of this method.

  14. Implantable Biosensors for Real-time Strain and Pressure Monitoring

    Directory of Open Access Journals (Sweden)

    Keat Ghee Ong

    2008-10-01

    Full Text Available Implantable biosensors were developed for real-time monitoring of pressure and strain in the human body. The sensors, which are wireless and passive, consisted of a soft magnetic material and a permanent magnet. When exposed to a low frequency AC magnetic field, the soft magnetic material generated secondary magnetic fields that also included the higher-order harmonic modes. Parameters of interest were determined by measuring the changes in the pattern of these higher-order harmonic fields, which was achieved by changing the intensity of a DC magnetic field generated by a permanent magnet. The DC magnetic field, or the biasing field, was altered by changing the separation distance between the soft magnetic material and the permanent magnet. For pressure monitoring, the permanent magnet was placed on the membrane of an airtight chamber. Changes in the ambient pressure deflected the membrane, altering the separation distance between the two magnetic elements and thus the higher-order harmonic fields. Similarly, the soft magnetic material and the permanent magnet were separated by a flexible substrate in the stress/strain sensor. Compressive and tensile forces flexed the substrate, changing the separation distance between the two elements and the higher-order harmonic fields. In the current study, both stress/strain and pressure sensors were fabricated and characterized. Good stability, linearity and repeatability of the sensors were demonstrated. This passive and wireless sensor technology may be useful for long term detection of physical quantities within the human body as a part of treatment assessment, disease diagnosis, or detection of biomedical implant failures.

  15. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  16. NASA evaluation of Type 2 chemical depositions. [effects of deicer deposition on aircraft tire friction performance

    Science.gov (United States)

    Yager, Thomas J.; Stubbs, Sandy M.; Howell, W. Edward; Webb, Granville L.

    1993-01-01

    Recent findings from NASA Langley tests to define effects of aircraft Type 2 chemical deicer depositions on aircraft tire friction performance are summarized. The Aircraft Landing Dynamics Facility (ALDF) is described together with the scope of the tire cornering and braking friction tests conducted up to 160 knots ground speed. Some lower speed 32 - 96 km/hr (20 - 60 mph) test run data obtained using an Instrumented Tire Test Vehicle (ITTV) to determine effects of tire bearing pressure and transverse grooving on cornering friction performance are also discussed. Recommendations are made concerning which parameters should be evaluated in future testing.

  17. A systematic experimental investigation of significant parameters affecting model tire hydroplaning

    Science.gov (United States)

    Wray, G. A.; Ehrlich, I. R.

    1973-01-01

    The results of a comprehensive parametric study of model and small pneumatic tires operating on a wet surface are presented. Hydroplaning inception (spin down) and rolling restoration (spin up) are discussed. Conclusions indicate that hydroplaning inception occurs at a speed significantly higher than the rolling restoration speed. Hydroplaning speed increases considerably with tread depth, surface roughness and tire inflation pressure of footprint pressure, and only moderately with increased load. Water film thickness affects spin down speed only slightly. Spin down speed varies inversely as approximately the one-sixth power of film thickness. Empirical equations relating tire inflation pressure, normal load, tire diameter and water film thickness have been generated for various tire tread and surface configurations.

  18. Local Leak Detection and Health Monitoring of Pressurized Tanks

    Science.gov (United States)

    Polzin, Kurt; Witherow, William; Korman, Valentin; Sinko, John; Hendrickson, Adam

    2011-01-01

    An optical gas-detection sensor safely monitors pressurized systems (such as cryogenic tanks) and distribution systems for leaks. This sensor system is a fiber-coupled, solid optical body interferometer that allows for the miniaturized sensing element of the device to be placed in the smallest of recesses, and measures a wide range of gas species and densities (leaks). The deflection of the fringe pattern is detected and recorded to yield the time-varying gas density in the gap. This technology can be used by manufacturers or storage facilities with toxic, hazardous, or explosive gases. The approach is to monitor the change in the index of refraction associated with low-level gas leaks into a vacuum environment. The completion of this work will provide NASA with an enabling capability to detect gas system leaks in space, and to verify that pressurized systems are in a safe (i.e. non-leaking) condition during manned docking and transit operations. By recording the output of the sensor, a time-history of the leak can be constructed to indicate its severity. Project risk is mitigated by having several interferometric geometries and detection techniques available, each potentially leveraging hardware and lessons learned to enhance detectability.

  19. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors

    Directory of Open Access Journals (Sweden)

    Deirdre M Mooney

    2015-10-01

    Full Text Available Heart failure (HF is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  20. Evolution from electrophysiologic to hemodynamic monitoring: the story of left atrial and pulmonary artery pressure monitors.

    Science.gov (United States)

    Mooney, Deirdre M; Fung, Erik; Doshi, Rahul N; Shavelle, David M

    2015-01-01

    Heart failure (HF) is a costly, challenging and highly prevalent medical condition. Hospitalization for acute decompensation is associated with high morbidity and mortality. Despite application of evidence-based medical therapies and technologies, HF remains a formidable challenge for virtually all healthcare systems. Repeat hospitalizations for acute decompensated HF (ADHF) can have major financial impact on institutions and resources. Early and accurate identification of impending ADHF is of paramount importance yet there is limited high quality evidence or infrastructure to guide management in the outpatient setting. Historically, ADHF was identified by physical exam findings or invasive hemodynamic monitoring during a hospital admission; however, advances in medical microelectronics and the advent of device-based diagnostics have enabled long-term ambulatory monitoring of HF patients in the outpatient setting. These monitors have evolved from piggybacking on cardiac implantable electrophysiologic devices to standalone implantable hemodynamic monitors that transduce left atrial or pulmonary artery pressures as surrogate measures of left ventricular filling pressure. As technology evolves, devices will likely continue to miniaturize while their capabilities grow. An important, persistent challenge that remains is developing systems to translate the large volumes of real-time data, particularly data trends, into actionable information that leads to appropriate, safe and timely interventions without overwhelming outpatient cardiology and general medical practices. Future directions for implantable hemodynamic monitors beyond their utility in heart failure may include management of other major chronic diseases such as pulmonary hypertension, end stage renal disease and portal hypertension.

  1. Biotelemetric Wireless Intracranial Pressure Monitoring: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Mohammad H. Behfar

    2015-01-01

    Full Text Available Assessment of intracranial pressure (ICP is of great importance in management of traumatic brain injuries (TBIs. The existing clinically established ICP measurement methods require catheter insertion in the cranial cavity. This increases the risk of infection and hemorrhage. Thus, noninvasive but accurate techniques are attractive. In this paper, we present two wireless, batteryless, and minimally invasive implantable sensors for continuous ICP monitoring. The implants comprise ultrathin (50 μm flexible spiral coils connected in parallel to a capacitive microelectromechanical systems (MEMS pressure sensor. The implantable sensors are inductively coupled to an external on-body reader antenna. The ICP variation can be detected wirelessly through measuring the reader antenna’s input impedance. This paper also proposes novel implant placement to improve the efficiency of the inductive link. In this study, the performance of the proposed telemetry system was evaluated in a hydrostatic pressure measurement setup. The impact of the human tissues on the inductive link was simulated using a 5 mm layer of pig skin. The results from the in vitro measurement proved the capability of our developed sensors to detect ICP variations ranging from 0 to 70 mmHg at 2.5 mmHg intervals.

  2. Clinical evaluation of a new intracranial pressure monitoring device.

    Science.gov (United States)

    Stendel, R; Heidenreich, J; Schilling, A; Akhavan-Sigari, R; Kurth, R; Picht, T; Pietilä, T; Suess, O; Kern, C; Meisel, J; Brock, M

    2003-03-01

    Continuous monitoring of intracranial pressure (ICP) still plays a key role in the management of patients at risk from intracranial hypertension. Numerous ICP-measuring devices are available. The aim of the present study was to investigate the clinical characteristics and the magnetic resonance imaging (MRI) compatibility of the recently developed Neurovent-P(REHAU AG+CO, REHAU, Germany) ICP monitoring device. In a prospective two-center study, a total of 98 patients with severe head injury, subarachnoid haemorrhage, intracerebral haemorrhage, and non-traumatic brain edema underwent intraparenchymal monitoring of ICP using the Neurovent-P. A control group comprising 50 patients underwent implantation of the Camino-OLM-110-4B ICP monitor. The zero drift of the probes was determined before and after the ICP recording period. Technical and medical complications were documented. The MRI compatibility of the Neurovent-P ICP probe was investigated by evaluating artifacts caused by the probe, probe function and temperature changes during MRI, and probe movement caused by the magnetic field. The mean zero drift was 0.2+/-0.41 mmHg (maximum 3 mmHg) for the Neurovent-P ICP probes and 0.4+/-0.57 mmHg (maximum 12 mmHg) for the Camino-OLM-110-4B ICP probes. No significant correlation was identified between the extent of zero drift following the removal of the probes and the length of monitoring. Intraparenchymal haemorrhage spatially related to the probe occurred in 1 out of 50 (2%) patients with a Camino-OLM-110-4B probe and in 1 out of 98 (1%) with a Neurovent-P. Damage of the probe due to kinking or overextension of the cable or glass fiber occurred in 4 of the 50 (8%) Camino-OLM-110-4B ICP probes and in 5 of the 98 (5%) Neurovent-P probes. On T2-weighted MR images, the Neurovent-P ICP probe induced only small artifacts with very good discrimination of the surrounding tissue. On T1-weighted MR images, there was a good imaging quality but artifact-related local disturbances

  3. Home blood-pressure monitoring in a hypertensive pregnant population.

    Science.gov (United States)

    Perry, H; Sheehan, E; Thilaganathan, B; Khalil, A

    2018-04-01

    The majority of patients with chronic or gestational hypertension do not develop pre-eclampsia. Home blood-pressure monitoring (HBPM) has the potential to offer a more accurate and acceptable means of monitoring hypertensive patients during pregnancy compared with traditional pathways of frequent outpatient monitoring. The aim of this study was to determine whether HBPM reduces visits to antenatal services and is safe in pregnancy. This was a case-control study of 166 hypertensive pregnant women, which took place at St George's Hospital, University of London. Inclusion criteria were: chronic hypertension, gestational hypertension or high risk of developing pre-eclampsia, no significant proteinuria (≤ 1+ proteinuria on dipstick testing) and normal biochemical and hematological markers. Exclusion criteria were maternal age  155 mmHg or diastolic blood pressure > 100 mmHg, significant proteinuria (≥ 2+ proteinuria on dipstick testing or protein/creatinine ratio > 30 mg/mmol), evidence of small-for-gestational age (estimated fetal weight < 10 th centile), signs of severe pre-eclampsia, significant mental health concerns or insufficient understanding of the English language. Pregnant women in the HBPM group were taught how to measure and record their blood pressure using a validated machine at home and attended every 1-2 weeks for assessment depending on clinical need. The control group was managed as per the local protocol prior to the implementation of HBPM. The two groups were compared with respect to number of visits to antenatal services and outcome. There were 108 women in the HBPM group and 58 in the control group. There was no difference in maternal age, parity, body mass index, ethnicity or smoking status between the groups, but there were more women with chronic hypertension in the HBPM group compared with the control group (49.1% vs 25.9%, P = 0.004). The HBPM group had significantly fewer outpatient attendances per patient (6

  4. 77 FR 10615 - Cooper Tire & Rubber Tire Company, Grant of Petition for Decision of Inconsequential Noncompliance

    Science.gov (United States)

    2012-02-22

    ... tread wear, temperature, and traction ratings, to assess performance capabilities of various tires. In...-0054; Notice 2] Cooper Tire & Rubber Tire Company, Grant of Petition for Decision of Inconsequential...: Cooper Tire & Rubber Tire Company, (Cooper) \\1\\, has determined that approximately 6,964 passenger car...

  5. 49 CFR 574.7 - Information requirements-new tire manufacturers, new tire brand name owners.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Information requirements-new tire manufacturers, new tire brand name owners. 574.7 Section 574.7 Transportation Other Regulations Relating to..., new tire brand name owners. (a)(1) Each new tire manufacturer and each new tire brand name owner...

  6. 76 FR 28502 - Cooper Tire & Rubber Tire Company, Receipt of Petition for Decision of Inconsequential Noncompliance

    Science.gov (United States)

    2011-05-17

    ...-0054; Notice 1] Cooper Tire & Rubber Tire Company, Receipt of Petition for Decision of Inconsequential Noncompliance Cooper Tire & Rubber Tire Company, (Cooper),\\1\\ has determined that approximately 6,964 passenger car replacement tires manufactured between January 23, 2011 and March 26, 2011, do not fully comply...

  7. On-line fatigue monitoring system for reactor pressure vessel

    International Nuclear Information System (INIS)

    Tokunaga, K.; Sakai, A.; Aoki, T.; Ranganath, S.; Stevens, G.L.

    1994-01-01

    A workstation-based, on-line fatigue monitoring system for tracking fatigue usage applied to an operating boiling water reactor (BWR), Tsuruga Unit-1, is described. The system uses the influence function approach and determines component stresses using temperature, pressure, and flow rate data that are made available via signal taps from previously existing plant sensors. Using plant unique influence functions developed specifically for the feedwater nozzle location, the system calculates stresses as a function of time and computed fatigue usage. The analysis method used to compute fatigue usage complies with MITI Code Notification No.501. Fatigue usage results for an entire fuel cycle are presented and compared to assumed design basis events to confirm that actual plant thermal duty is significantly less severe than originally estimated in the design basis stress report. As a result, the system provides the technical basis to more accurately evaluate actual reactor conditions as well as the justification for plant life extension. (author)

  8. Oxidative desulfurization of tire pyrolysis oil

    Directory of Open Access Journals (Sweden)

    Ahmad Shahzad

    2016-01-01

    Full Text Available This paper presents a low cost method for the purification of oils obtained from the pyrolysis of used tires. Oxidative desulfurization is a promising route for purification of tire pyrolysis oils as hydro-desulfurization may not be affordable for small scale industries. Different additives and acids have been employed for the enhancement of properties of pyrolytic oils. The experimental conditions were kept identical throughout, i.e. atmospheric pressure and 50°C temperature for comparison of performance of various additives. The use of hydrogen peroxide-acetic acid mixture (10 wt.% was found more economical and effective in desulfurization and improvement of fuel properties of sample oils. The contribution of sulfuric acid in desulfurization and decreasing viscosity was also satisfactory but due to high price of concentrated sulfuric acid its use may not be economical. Calcium oxide and Fuller’s earth was not found to be effective in desulfurization. Results indicate that oxidative desulfurization could render tire pyrolysis oils suitable for blending as heating fuel.

  9. 30 CFR 57.14104 - Tire repairs.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tire repairs. 57.14104 Section 57.14104 Mineral... Devices and Maintenance Requirements § 57.14104 Tire repairs. (a) Before a tire is removed from a vehicle for tire repair, the valve core shall be partially removed to allow for gradual deflation and then...

  10. 30 CFR 56.14104 - Tire repairs.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tire repairs. 56.14104 Section 56.14104 Mineral... Devices and Maintenance Requirements § 56.14104 Tire repairs. (a) Before a tire is removed from a vehicle for tire repair, the valve core shall be partially removed to allow for gradual deflation and then...

  11. Airplane tire inspection by image processing techniques

    OpenAIRE

    Jovancevic , Igor; Arafat , Al; Orteu , Jean-José; Sentenac , Thierry

    2016-01-01

    International audience; In this paper, we propose a new approach to detect and inspect airplane tires. We use normalized correlation based template matching to detect tires and GrabCut segmentation method to extract them from the background. We inspect the tires condition by investigating the tire treads. Ridge based intensity profiling gives satisfying inspection results.

  12. NUMERICAL MODELLING AND EXPERIMENTAL INFLATION VALIDATION OF A BIAS TWO-WHEEL TIRE

    Directory of Open Access Journals (Sweden)

    CHUNG KET THEIN

    2016-02-01

    Full Text Available This paper presents a parametric study on the development of a computational model for bias two-wheel tire through finite element analysis (FEA. An 80/90- 17 bias two-wheel tire was adopted which made up of four major layers of rubber compound with different material properties to strengthen the structure. Mooney-Rivlin hyperelastic model was applied to represent the behaviour of incompressible rubber compound. A 3D tire model was built for structural static finite element analysis. The result was validated from the inflation analysis. Structural static finite element analysis method is suitable for evaluation of the tire design and improvement of the tire behaviour to desired performance. Experimental tire was inflated at various pressures and the geometry between numerical and experimental tire were compared. There are good agreements between numerical simulation model and the experiment results. This indicates that the simulation model can be applied to the bias two-wheel tire design in order to predict the tire behaviour and improve its mechanical characteristics.

  13. Thermal micropressure sensor for pressure monitoring in a minute package

    International Nuclear Information System (INIS)

    Wang, S. N.; Mizuno, K.; Fujiyoshi, M.; Funabashi, H.; Sakata, J.

    2001-01-01

    A thermal micropressure sensor suitable for pressure measurements in the range from 7x10 -3 to 1x10 5 Pa has been fabricated by forming a titanium (Ti) thin-film resistor on a floating nondoped silica glass membrane, with the sensing area being as small as 60 μmx60 μm. The sensor performance is raised by: (1) increasing the ratio of gaseous thermal conduction in the total thermal conduction by sensor structure design; (2) compensating the effect of ambient-temperature drift by using a reference resistor located close to the sensing element but directly on the silicon substrate; and (3) utilizing an optimized novel constant-bias Wheatstone bridge circuit. By choosing a proper bias voltage, which can be found by simple calculation, the circuit extracts information on gaseous thermal conduction from the directly measurable total heat loss of the heated sensing element. The sensor was enclosed in a metal package with a capacity of about 0.5 ml by projection welding and was successfully applied to monitoring the pressure in the minute space

  14. Blood Pressure Mobile Monitoring for Pregnant Woman Based Android System

    Science.gov (United States)

    Supriyanti, Retno; Erfayanto, Uji; Ramadani, Yogi; Murdyantoro, Eko; Widodo, Haris B.

    2016-01-01

    Currently, at least 18,000 women die every year in Indonesia due to pregnancy or childbirth. It means that every half hour a woman dies due to pregnancy or childbirth. As a result, every year 36,000 children became orphans. The high maternal mortality rate was put Indonesia on top in ASEAN. The main causes of maternal mortality are high-risk pregnancy. Mothers who have diseases like high blood pressure, pre-eclampsia, diabetes, hyperthyroidism, and already over 40 years old and infectious diseases such as rubella, hepatitis and HIV can be factors that lead to high-risk pregnancy. This paper will discuss the development of a blood pressure monitoring device that is suitable for pregnant women. It is based on convenience for pregnant women to get the equipment that is flexible with her presence. Results indicate that the equipment is in use daily support for pregnant women therefore, one of the causes of maternal mortality can be detected earlier.

  15. Ambulatory blood pressure monitoring in healthy children with parental hypertension.

    Science.gov (United States)

    Alpay, Harika; Ozdemir, Nihal; Wühl, Elke; Topuzoğlu, Ahmet

    2009-01-01

    The aim of this study was to compare ambulatory blood pressure monitoring (ABPM) parameters in offspring with at least one hypertensive parent (HP) to offspring with normotensive parents (NP) and to determine whether gender of parent or child might influence the association between parental hypertension and blood pressure (BP). Eighty-nine healthy children (mean age 11.1 +/- 3.9 years) with HP and 90 controls (mean age 10.5 +/- 3.1 years) with NP were recruited. Age, gender, and height did not differ between the two groups, whereas children of HP had higher weight, body mass index (BMI), and waist circumference compared with healthy controls. No difference was found in casual BP between the two groups. In contrast, during ABPM daytime and nighttime mean systolic and diastolic BP and mean arterial pressure (MAP) standard deviation scores (SDS) were significantly elevated in children with HP. The mean percentage of nocturnal BP decline (dipping) was not significantly different between the two groups. Children with hypertensive mothers had higher daytime systolic and MAP SDS than controls; no such difference was detected for children with hypertensive fathers. Daytime systolic and MAP SDS were significantly elevated in boys with HP compared with boys with NP but failed to be significant in girls. Multiple linear regression analysis showed that parental history of hypertension (B = 0.29) and BMI (B = 0.03) were independently correlated with increase of daytime MAP SDS. Early changes in ambulatory BP parameters were present in healthy children of HP. BP in HP offspring was influenced by the gender of the affected parent and the offspring.

  16. Telemetric intra-cranial pressure monitoring: clinical and financial considerations.

    Science.gov (United States)

    Barber, James M; Pringle, Catherine J; Raffalli-Ebezant, Helen; Pathmanaban, Omar; Ramirez, Roberto; Kamaly-Asl, Ian D

    2017-06-01

    Intracranial pressure (ICP) measurement is an important diagnostic tool in Neurosurgery. Until relatively recently, conventional monitoring has required that subjects be admitted to a hospital bed and the device is only able to be left in-situ for limited periods of time. We have evaluated a Telemetric ICP monitoring system that has been proven, by several other groups worldwide, to permit rapid, repeated and prolonged ICP measurement, in multiple environments. In our unit, 4 patients have been implanted to-date, between the ages of 4 and 16, manifesting a wide range of complex neurosurgical conditions. The sensors have been left in-situ for between 460 and 632 days. There have been no clinical complications and the system has been universally well tolerated. Clinical events, costs and patient experience were all assessed prior to and following implantation. Overall, there was a significant reduction in associated admissions (44.3%), imaging requirements (72.5%) and costs (50.0%). Subjective feedback from both the patients (where possible) and their families was overwhelmingly positive, partly due to (a) the system's ease of use, (b) its ability to reduce the number of admissions/tests required and (c) the facility for rapid measurement of ICP that permitted on-the-spot reassurance of concerns. Additionally, the ability to monitor ICP at home and/or whilst ambulant, has provided measurements that were hitherto inaccessible to our team, facilitating all the potential benefits that analysis of such information would provide. Indeed, we have seen the resultant management in each case has been completely altered by the availability of this data, reaffirming that the importance of being able to obtain it should not be underestimated. The combination of both this and the ability to markedly improve patient experience, along with generating significant cost-savings, lead the authors to suggest that the implantation of this system should be strongly considered in selected

  17. Optimization of an Optical Test Bench for Tire Properties Measurement and Tread Defects Characterization

    Directory of Open Access Journals (Sweden)

    Juan Jesús Castillo Aguilar

    2017-03-01

    Full Text Available Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures.

  18. Blood pressure monitoring: theory and practice. European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability Teaching Course Proceedings.

    Science.gov (United States)

    Stergiou, George S; Palatini, Paolo; Asmar, Roland; Bilo, Grzegorz; de la Sierra, Alejandro; Head, Geoff; Kario, Kazuomi; Mihailidou, Anastasia; Wang, Jiguang; Mancia, Giuseppe; O'Brien, Eoin; Parati, Gianfranco

    2018-02-01

    The European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring and Cardiovascular Variability organized a Teaching Course on 'Blood Pressure Monitoring: Theory and Practice' during the 2017 ESH Meeting in Milan, Italy. This course performed by 11 international BP monitoring experts covered key topics of BP monitoring, including office BP measurement, ambulatory BP monitoring, home BP monitoring, ambulatory versus home BP, white-coat and masked hypertension, cuff use, and BP variability. This article presents a summary of the proceedings of the ESH BP Monitoring Teaching Course, including essential information, practical issues, and recommendations on the clinical application of BP monitoring methods, aiming to the optimal management of patients with suspected or diagnosed hypertension.

  19. Intracranial pressure monitoring in severe blunt head trauma: does the type of monitoring device matter?

    Science.gov (United States)

    Aiolfi, Alberto; Khor, Desmond; Cho, Jayun; Benjamin, Elizabeth; Inaba, Kenji; Demetriades, Demetrios

    2018-03-01

    OBJECTIVE Intracranial pressure (ICP) monitoring has become the standard of care in the management of severe head trauma. Intraventricular devices (IVDs) and intraparenchymal devices (IPDs) are the 2 most commonly used techniques for ICP monitoring. Despite the widespread use of these devices, very few studies have investigated the effect of device type on outcomes. The purpose of the present study was to compare outcomes between 2 types of ICP monitoring devices in patients with isolated severe blunt head trauma. METHODS This retrospective observational study was based on the American College of Surgeons Trauma Quality Improvement Program database, which was searched for all patients with isolated severe blunt head injury who had an ICP monitor placed in the 2-year period from 2013 to 2014. Extracted variables included demographics, comorbidities, mechanisms of injury, head injury specifics (epidural, subdural, subarachnoid, intracranial hemorrhage, and diffuse axonal injury), Abbreviated Injury Scale (AIS) score for each body area, Injury Severity Score (ISS), vital signs in the emergency department, and craniectomy. Outcomes included 30-day mortality, complications, number of ventilation days, intensive care unit and hospital lengths of stay, and functional independence. RESULTS During the study period, 105,721 patients had isolated severe traumatic brain injury (head AIS score ≥ 3). Overall, an ICP monitoring device was placed in 2562 patients (2.4%): 1358 (53%) had an IVD and 1204 (47%) had an IPD. The severity of the head AIS score did not affect the type of ICP monitoring selected. There was no difference in the median ISS; ISS > 15; head AIS Score 3, 4, or 5; or the need for craniectomy between the 2 device groups. Unadjusted 30-day mortality was significantly higher in the group with IVDs (29% vs 25.5%, p = 0.046); however, stepwise logistic regression analysis showed that the type of ICP monitoring was not an independent risk factor for death

  20. NDE and Stress Monitoring on Composite Overwrapped Pressure Vessels, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Damage caused by composite overwrapped pressure vessels (COPVs) failure can be catastrophic. Thus, monitoring condition and stress in the composite overwrap,...

  1. Rubber friction and tire dynamics

    International Nuclear Information System (INIS)

    Persson, B N J

    2011-01-01

    We propose a simple rubber friction law, which can be used, for example, in models of tire (and vehicle) dynamics. The friction law is tested by comparing numerical results to the full rubber friction theory (Persson 2006 J. Phys.: Condens. Matter 18 7789). Good agreement is found between the two theories. We describe a two-dimensional (2D) tire model which combines the rubber friction model with a simple mass-spring description of the tire body. The tire model is very flexible and can be used to accurately calculate μ-slip curves (and the self-aligning torque) for braking and cornering or combined motion (e.g. braking during cornering). We present numerical results which illustrate the theory. Simulations of anti-blocking system (ABS) braking are performed using two simple control algorithms.

  2. Rubber friction and tire dynamics.

    Science.gov (United States)

    Persson, B N J

    2011-01-12

    We propose a simple rubber friction law, which can be used, for example, in models of tire (and vehicle) dynamics. The friction law is tested by comparing numerical results to the full rubber friction theory (Persson 2006 J. Phys.: Condens. Matter 18 7789). Good agreement is found between the two theories. We describe a two-dimensional (2D) tire model which combines the rubber friction model with a simple mass-spring description of the tire body. The tire model is very flexible and can be used to accurately calculate μ-slip curves (and the self-aligning torque) for braking and cornering or combined motion (e.g. braking during cornering). We present numerical results which illustrate the theory. Simulations of anti-blocking system (ABS) braking are performed using two simple control algorithms.

  3. Method and apparatus for inspecting tires

    International Nuclear Information System (INIS)

    Fox, R.L.T.

    1975-01-01

    A method and apparatus for inspecting tires by the use of x-rays is disclosed in which a tire is advanced to an inspection station, engaged along opposite bead rims and inflated to axially spread the bead rims and side walls. An x-ray source is advanced axially into the tire and the tire is eccentrically rotated relative to the x-ray source to enable radial positioning of the source relative to the tire near the tire bead rim diameter without requiring radial movement of the x-ray source. The x-ray source produces an x-ray beam which sweeps about the interior of the expanded tire from bead rim to bead rim while the tire is rotated about its centerline. An x-ray detection system detects x-rays which have penetrated the wall and produces inspection information concerning the tire construction. (Patent Office Record)

  4. Underwater television camera for monitoring inner side of pressure vessel

    International Nuclear Information System (INIS)

    Takayama, Kazuhiko.

    1997-01-01

    An underwater television support device equipped with a rotatable and vertically movable underwater television camera and an underwater television camera controlling device for monitoring images of the inside of the reactor core photographed by the underwater television camera to control the position of the underwater television camera and the underwater light are disposed on an upper lattice plate of a reactor pressure vessel. Both of them are electrically connected with each other by way of a cable to rapidly observe the inside of the reactor core by the underwater television camera. The reproducibility is extremely satisfactory by efficiently concentrating the position of the camera and image information upon inspection and observation. As a result, the steps for periodical inspection can be reduced to shorten the days for the periodical inspection. Since there is no requirement to withdraw fuel assemblies over a wide reactor core region, and the device can be used with the fuel assemblies being left as they are in the reactor, it is suitable for inspection of detectors for nuclear instrumentation. (N.H.)

  5. Grip Analysis of Road Surface and Tire Footprint Using FEM

    Science.gov (United States)

    Sabri, M.; Abda, S.

    2018-02-01

    Road grip involve a touch between road pavement and the tire tread pattern. The load bearing surface, which depends on pavement roughness and local pressures in the contact patch. This research conducted to develop a Finite element model for simulating the experimentally testing of asphalt in Jl. AH Nasution Medan, North Sumatera Indonesia base on the value of grip coefficient from various tire loads and the various speed of the vehicle during contact to the road. A tire model and road pavement are developed for the analyses the geometry of tire footprint. The results showed that the greater the mass of car will increase grip coefficient. The coefficient of grip on the road surface contact trough the tire footprint strongly influence the kinetic coefficient of friction at certain speeds. Experimentally show that Concrete road grip coefficient of more than 34% compared to the asphalt road at the same IRI parameters (6-8). Kinetic friction coefficient more than 0.33 was obtained in a asphalt path at a speed of 30-40 Km/hour.

  6. Direct molding of pavement tiles made of ground tire rubber

    Science.gov (United States)

    Quadrini, Fabrizio; Gagliardi, Donatella; Tedde, Giovanni Matteo; Santo, Loredana; Musacchi, Ettore

    2016-10-01

    Large rubber products can be molded by using only ground tire rubber (GTR) without any additive or binder due to a new technology called "direct molding". Rubber granules and powders from tire recycling are compression molded at elevated temperatures and pressures. The feasibility of this process was clearly shown in laboratory but the step to the industrial scale was missing. Thanks to an European Project (SMART "Sustainable Molding of Articles from Recycled Tires") this step has been made and some results are reported in this study. The press used for compression molding is described. Some tests were made to measure the energy consumption so as to evaluate costs for production in comparison with conventional technologies for GTR molding (by using binders). Results show that 1 m2 tiles can be easily molded with several thicknesses in a reasonable low time. Energy consumption is higher than conventional technologies but it is lower than the cost for binders.

  7. Choking under monitoring pressure: being watched by the experimenter reduces executive attention.

    Science.gov (United States)

    Belletier, Clément; Davranche, Karen; Tellier, Idriss S; Dumas, Florence; Vidal, Franck; Hasbroucq, Thierry; Huguet, Pascal

    2015-10-01

    Performing more poorly given one's skill level ("choking") is likely in situations that offer an incentive if a certain outcome is achieved (outcome pressure) or when one is being watched by others-especially when one's performance is being evaluated (monitoring pressure). According to the choking literature, outcome pressure is associated with reduced executive control of attention, whereas monitoring pressure is associated with increased, yet counterproductive, attention to skill processes. Here, we show the first evidence that monitoring pressure-being watched by the experimenter-may lead individuals with higher working memory to choke on a classic measure of executive control-just the task effect thought to result from outcome pressure. Not only does this finding help refine our understanding of the processes underlying choking under monitoring pressure, but it also leads to a new look at classic audience effects, with an important implication for experimental psychology.

  8. Twenty-Four-Hour Ambulatory Blood Pressure Monitoring in Hypertension

    Science.gov (United States)

    2012-01-01

    Executive Summary Objective The objective of this health technology assessment was to determine the clinical effectiveness and cost-effectiveness of 24-hour ambulatory blood pressure monitoring (ABPM) for hypertension. Clinical Need: Condition and Target Population Hypertension occurs when either systolic blood pressure, the pressure in the artery when the heart contracts, or diastolic blood pressure, the pressure in the artery when the heart relaxes between beats, are consistently high. Blood pressure (BP) that is consistently more than 140/90 mmHg (systolic/diastolic) is considered high. A lower threshold, greater than 130/80 mmHg (systolic/diastolic), is set for individuals with diabetes or chronic kidney disease. In 2006 and 2007, the age-standardized incidence rate of diagnosed hypertension in Canada was 25.8 per 1,000 (450,000 individuals were newly diagnosed). During the same time period, 22.7% of adult Canadians were living with diagnosed hypertension. A smaller proportion of Canadians are unaware they have hypertension; therefore, the estimated number of Canadians affected by this disease may be higher. Diagnosis and management of hypertension are important, since elevated BP levels are related to the risk of cardiovascular disease, including stroke. In Canada in 2003, the costs to the health care system related to the diagnosis, treatment, and management of hypertension were over $2.3 billion (Cdn). Technology The 24-hour ABPM device consists of a standard inflatable cuff attached to a small computer weighing about 500 grams, which is worn over the shoulder or on a belt. The technology is noninvasive and fully automated. The device takes BP measurements every 15 to 30 minutes over a 24-to 28-hour time period, thus providing extended, continuous BP recordings even during a patient’s normal daily activities. Information on the multiple BP measurements can be downloaded to a computer. The main detection methods used by the device are auscultation and

  9. Acceleration sensitivity of micromachined pressure sensors

    Science.gov (United States)

    August, Richard; Maudie, Theresa; Miller, Todd F.; Thompson, Erik

    1999-08-01

    Pressure sensors serve a variety of automotive applications, some which may experience high levels of acceleration such as tire pressure monitoring. To design pressure sensors for high acceleration environments it is important to understand their sensitivity to acceleration especially if thick encapsulation layers are used to isolate the device from the hostile environment in which they reside. This paper describes a modeling approach to determine their sensitivity to acceleration that is very general and is applicable to different device designs and configurations. It also describes the results of device testing of a capacitive surface micromachined pressure sensor at constant acceleration levels from 500 to 2000 g's.

  10. Loading Effect on Tire Noise Radiation

    OpenAIRE

    Cao, Rui; Bolton, J Stuart

    2016-01-01

    Noise radiated by tires is a prominent noise pollution source and it is affected by many different parameters. Here, the effect of static load on tire noise radiation in a laboratory environment was investigated. The measurement was conducted by using the Tire Pavement Testing Apparatus (TPTA), on which a loaded tire can be run at speeds up to 50 km/hr; the tire noise was measured using a nearfield microphone method. The tire loading was varied from 500 to 900 pounds, and several different co...

  11. 3rd symposium on tires and chassis; 3. Symposium Reifen und Fahrwerk

    Energy Technology Data Exchange (ETDEWEB)

    Geringer, B.; Stumpf, H. (comps.)

    2005-07-01

    The present volume contains the talks, which were held at the 3rd symposium on ''Tires and chassis'' at the Institute for combustion machines at the Technical University Vienna on 26th September 2005 in cooperation with UAMTTC and Semperit Reifen Ges.m.H. Apart from technical improvements on chassis, tires and carriageway the overall perspective will get more important in the future, which also includes the driver, the neighbour, the environment and the traffic policy. Due to an increasing number of international participants, discussions can be expected, which will take into consideration extraordinary and manifold perspectives. The third symposium on ''Tires and chassis'' discusses the following developments, of which some are evolutionary. (a) Tire engineering; environmental aspects of tires, roll resistance of tires, driving comfort of tires, winter tires for passenger vehicles and trucks. (b) vehicle engineering, engineering of a race car chassis by means of telemetric measuring data acquisition; simulation of steering wheel vibrations on a complete vehicle test stand. (c) Vehicle steering; chassis of tracklaying vehicles; automatic air pressure control. (orig.)

  12. Home Monitoring of Blood Pressure: Patients' Perception and Role ...

    African Journals Online (AJOL)

    measuring devices, patients' emotional response to their blood pressure readings and actions taken in response. ... pressure, their response regarding different readings, and the .... pivotal position for providing pharmaceutical care services ...

  13. Ambulatory blood pressure monitoring: Is 24 hours necessary?

    Science.gov (United States)

    Vornovitsky, Michael; McClintic, Benjamin R; Beck, G Ronald; Bisognano, John D

    2013-01-01

    The variability of blood pressure (BP) makes any single measurement a poor indicator of a patient's true BP. Multiple studies have confirmed the superiority of ambulatory BP measurements over clinic BP measurements in predicting cardiovascular risk; however, this method presents the problem of patient acceptance as it causes frequent arm discomfort and sleep disturbance. We hypothesized that 6 h of daytime BP measurements would result in slightly higher BP readings, yet reveal similar clinical decision making when compared to 24 h of BP measurements. The source for writing this article was a retrospective analysis of 30 patients who underwent ambulatory BP monitoring. Data obtained included: age, sex, ethnicity, baseline medical problems, medications, laboratory values, reason given for ordering 24-h ambulatory BP measurements, ambulatory BP measurements, and a subsequent decision to change medication. The average BP of the 24-h measurements was 127/75 mm Hg and the average BP of the 6-h daytime measurements was 131/79 mm Hg (SD 15, p = 0.009). Twenty-six out of 30 patients were at goal or pre-hypertensive. Two out of 30 patients had stage 1 hypertension and 2 out of 30 patients had stage 2 hypertension. Thirteen out of 30 patients had nocturnal dipping. Twelve out of 30 patients had a change in medication, but those changes were not associated with the presence or absence of nocturnal dipping (p = 0.5) or other factors beyond mean BP. Although there was a statistically significant, 4 mm Hg systolic difference between 24-h and 6-h average BP readings, there was no evidence that this difference led to changes in clinical management. The presence or absence of nocturnal dipping was not associated with a change in medication. We conclude that 6-h daytime ambulatory BP measurements provide sufficient information to guide clinical decision making without the problems of patient acceptance, arm discomfort, and sleep disturbance associated with 24-h BP measurements.

  14. Is it possible to shorten ambulatory blood pressure monitoring?

    Science.gov (United States)

    Wolak, Talya; Wilk, Lior; Paran, Esther; Wolak, Arik; Gutmacher, Bella; Shleyfer, Elena; Friger, Michael

    2013-08-01

    The aim of this investigation was to find a time segment in which average blood pressure (BP) has the best correlation with 24-hour BP control. A total of 240 patients with full ambulatory BP monitoring (ABPM) were included; 120 had controlled BP (systolic BP [SBP] ≤135 mm Hg and diastolic BP [DBP] ≤85 mm Hg) and 120 had uncontrolled BP (SBP >135 mm Hg and/or DBP >85 mm Hg). Each ABPM was divided into 6- and 8-hour segments. Evaluation for correlation between mean BP for each time segment and 24-hour BP control was performed using receiver operating characteristic curve analysis and Youden's index for threshold with the best sensitivity and specificity. The mean BP in the following segments showed the highest area under the curve (AUC) compared with average controlled 24-hour BP: SBP 2 am to 8 am (AUC, 0.918; threshold value of 133.5 mm Hg, sensitivity-0.752 and specificity-0.904); SBP 2 pm to 10 pm (AUC, 0.911; threshold value of 138.5 mm Hg, sensitivity-0.803 and specificity-0.878); and SBP 6 am to 2 pm (AUC, 0.903; threshold value of 140.5 mm Hg, sensitivity-0.778 and specificity-0.888). The time segment 2 pm to 10 pm was shown to have good correlation with 24-hour BP control (AUC >0.9; sensitivity and specificity >80%). This time segment might replace full ABPM as a screening measure for BP control or as abbreviated ABPM for patients with difficulty in performing full ABPM. © 2013 Wiley Periodicals, Inc.

  15. Ambulatory blood pressure monitoring in patients with hyperthyroidism before the introduction of therapy and on therapy

    Directory of Open Access Journals (Sweden)

    Stojanović Miloš

    2017-01-01

    Full Text Available The increased secretion of thyroid gland hormones affects the cardiovascular system by increasing heart rate and often by increasing systolic and diastolic blood pressure. We examined the influence of elevated thyroid hormone on blood pressure. Blood pressure monitoring was performed prior to the introduction of therapy in people with increased FT4 and on therapy when FT4 was in the normal range. We analyzed 32 people, of which 26 women had normal blood pressure values measured by blood pressure monitoring. Average age 45 and body mass index 27 kg/m2. Blood pressure was measured by monitoring blood pressure for 24 hours. On average, before the introduction of the therapy, it was 133/83 mmHg P 96 / min. The blood pressure on average on therapy with tireosuppressive was 128/82 mmHg P 74 / min. The Wilcoxon-Mann-Whitney paired test shows a significant P <0.05 higher systolic blood pressure and pulse rate during the day and night before the treatment, when FT4 was higher, than the time when medication was taking, when the FT4 was in the normal range. No significant difference was found for diastolic blood pressure before the introduction of therapy and during therapy with tireosuppressives. When values of FT4 are increased, monitoring of blood pressure shows significantly higher values of systolic blood pressure and pulse during day and night compared to systolic blood pressure and pulse values when FT4 is in the normal range.

  16. Analysis of automotive tire construction. Jidosha tire no kozo kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, K. (Toyo Tire and Rubber Co. Ltd., Osaka (Japan))

    1993-06-15

    This paper introduces features and trends of analyzing performance and construction of automotive tires. Tires are demanded of high durability, high motion performance, good comfort performance for vibration and noise, and low fuel consumption performance. A feature of analyzing the construction is to execute a modelling assuming that a tire has air-rigid flexible structure and rubber materials show hyperelastic behavior, hypothesizing a strain energy density function. In addition, a tire is highly incompressible. Visco elasticity and anti-friction performance are also important points. Rubber and cord layers have elastic characteristic of three-dimensional perpendicular anisotropy as well as non-linearity with which characteristics change according to transformation. A structural analysis must cover from static analysis to steady dynamic analysis, non-steady dynamic analysis, and eigenvalue analysis. Thermal analysis of tires simulates phenomena by combining dynamical analysis with thermal analysis. Super-computers have now come to be used for formulating equilibrium equations using finite element methods, developing finite elements, and performing heat or visco elasticity analysis and applied analysis. 35 refs., 3 figs.

  17. Wearable Beat to Beat Blood Pressure Monitor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A key component of NASA's human exploration programs is a system that monitors the health of the crew during the space missions. The wearable physiological monitor...

  18. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial

    DEFF Research Database (Denmark)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter

    2018-01-01

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark....... One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent...... a reduction of blood pressure. Clinical Trials NCT00244660....

  19. [A design and study of a novel electronic device for cuff-pressure monitoring].

    Science.gov (United States)

    Wang, Shupeng; Li, Wei; Li, Wen; Song, Dejing; Chen, Desheng; Duan, Jun; Li, Chen; Li, Gang

    2017-06-01

    To design a novel electronic device for measuring the pressure in the cuff of the artificial airway; and to study the advantage of this device on continuous and intermittent cuff pressure monitoring. (1) a portable electronic device for cuff pressure measurement was invented, which could turn pressure signal into electrical signal through a pressure transducer. Meantime, it was possible to avoid pressure leak from the joint and the inside of the apparatus by modified Luer taper and sophisticated design. If the cuff pressure was out of the normal range, the apparatus could release a sound and light alarm. (2) Six traditional mechanical manometers were used to determine the cuff pressure in 6 tracheal tubes. The cuff pressure was maintain at 30 cmH 2 O (1 cmH 2 O = 0.098 kPa) by the manometer first, and repeated every 30 seconds for 4 times. (3) Study of continuous cuff pressure monitoring: We used a random number generator to randomize 6 tracheal tubes, 6 mechanical manometers and 6 our products by number 1-6, which has the same number of a group. Every group was further randomized into two balanced groups, one group used the mechanical manometer first, and the other used our product first. The baseline pressure was 30 cmH 2 O, measurement was performed every 4 hours for 6 times. When traditional mechanical manometer was used for cuff pressure monitoring, cuff pressure was decreased by an average of 2.9 cmH 2 O for each measurement (F = 728.2, P = 0.000). In study of continually monitoring, at each monitoring point, the pressure measured by electronic manometer was higher than the mechanical manometer. All the pressures measured by mechanical manometer were dropped below 20 cmH 2 O at 8th hour, and there was no pressure decrease below 20 cmH 2 O measured by electronic manometer in 24 hours by contrast. In study of intermittent monitoring, the same result was found. The pressure was dropped significantly with time when measured by mechanical manometer (F = 61.795, P

  20. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  1. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  2. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  3. Tire-soil interaction model for turning (steered) tires

    Science.gov (United States)

    Karafiath, L. L.

    1985-07-01

    A review of the experimental information on the development of lateral forces on tires traveling at an angle to their center plane is presented and the usefulness of the consideration of the lateral forces for the development of an analytical model is evaluated. Major components of the lateral force have been identified as the forces required to balance the tractive force and the drawbar pull vectorially. These are the shear stresses developing in the contact area and the horizontal component of the normal stresses acting on the in-ground portion or the curved side walls of the tire. The tire-soil interaction model for steady state straight travel has been expanded to include the necessary algorithms for the calculation of these lateral forces. The pattern of tractive force-slip and longitudinal-lateral force relationships is in general agreement with experiments.

  4. AIR EMISSIONS FROM SCRAP TIRE COMBUSTION

    Science.gov (United States)

    The report discusses air emissions from two types of scrap tire combustion: uncontrolled and controlled. Uncontrolled sources are open tire fires, which produce many unhealthful products of incomplete combustion and release them directly into the atmosphere. Controlled combustion...

  5. Ambulatory blood pressure monitoring and microalbuminuria in normotensive subjects with insulin-dependent diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Cohen Cesar Nissan

    2000-01-01

    Full Text Available OBJECTIVE: To assess the association between microalbuminuria with ambulatory blood pressure monitoring in normotensive individuals with insulin-dependent diabetes mellitus. METHODS: Thirty-seven patients underwent determination of the rate of urinary excretion of albumin through radioimmunoassay and ambulatory blood pressure monitoring. Their mean age was 26.5±6.7 years, and the mean duration of their disease was 8 (1-34 years. Microalbuminuria was defined as urinary excretion of albumin > or = 20 and 50% and diastolic pressure load > 30% during sleep was associated with microalbuminuria (p=0.008. The pressure drop during sleep did not differ between the groups. CONCLUSION: Microalbuminuric normotensive insulin-dependent diabetic patients show greater mean pressure value and pressure load during ambulatory blood pressure monitoring, and these variables correlate with urinary excretion of albumin.

  6. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.

    Science.gov (United States)

    Wiesel, Joseph; Arbesfeld, Benjamin; Schechter, David

    2014-10-01

    Screening for atrial fibrillation (AF) by assessing the pulse is recommended in high-risk patients. Some clinical trials demonstrated that the Microlife blood pressure monitor (BPM) with AF detection is more accurate than pulse palpation. This led to a change in practice guidelines in the United Kingdom where AF screening with the Microlife device is recommended instead of pulse palpation. Many BPMs have irregular heart beat detection, but they have not been shown to detect AF reliably. Recently, one study, in a highly select population, suggested that the Omron BPM with irregular heart beat detection has a higher sensitivity for AF than the Microlife BPM. We compared the Microlife and Omron BPMs to electrocardiographic readings for AF detection in general cardiology patients. Inclusion criteria were age≥50 years without a pacemaker or defibrillator. A total of 199 subjects were enrolled, 30 with AF. Each subject had a 12-lead electrocardiography, 1 Omron BPM reading, and 3 Microlife BPM readings as per device instructions. The Omron device had a sensitivity of 30% (95% confidence interval [CI] 15.4% to 49.1%) with the sensitivity for the first Microlife reading of 97% (95% CI 81.4% to 100%) and the Microlife readings using the majority rule (AF positive if at least 2 of 3 individual readings were positive for AF) of 100% (95% CI 85.9% to 100%). Specificity for the Omron device was 97% (95% CI 92.5% to 99.2%) and for the first Microlife reading of 90% (95% CI 83.8% to 94.2%) and for the majority rule Microlife device of 92% (95% CI 86.2% to 95.7%; p<0.0001). The specificity of both devices is acceptable, but only the Microlife BPM has a sensitivity value that is high enough to be used for AF screening in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Perfect sound insulation property of reclaimed waste tire rubber

    Science.gov (United States)

    Ubaidillah, Harjana, Yahya, Iwan; Kristiani, Restu; Muqowi, Eki; Mazlan, Saiful Amri

    2016-03-01

    This article reports an experimental investigation of sound insulation and absorption performance of a materials made of reclaimed ground tire rubber which is known as un-recyclable thermoset. The bulk waste tire is processed using single step recycling methods namely high-pressure high-temperature sintering (HPHTS). The bulk waste tire is simply placed into a mold and then a pressure load of 3 tons and a heating temperature of 200°C are applied to the mold. The HPHTS conducted for an hour and then it is cooled in room temperature. The resulted product is then evaluated the acoustical properties namely sound transmission loss (STL) and sound absorption coefficient using B&K Tube Kit Type 4206-T based on ISO 10534-2, ASTM E1050 and ASTM E2611. The sound absorption coefficient is found about 0.04 until 0.08 while STL value ranges between 50 to 60 dB. The sound absorption values are found to be very low (<0.1), while the average STL is higher than other elastomeric matrix found in previous work. The reclaimed tire rubber through HPHTS technique gives good soundproof characteristic.

  8. DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRES-SURE MONITORING

    Directory of Open Access Journals (Sweden)

    Mansoor Moazenzadeh

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: The study was conducted to define the determinants of suboptimal blood pressure (BP control among hypertensive patients under treatment and explore a predictive model for detecting the patients at risk for increased BP.    METHODS: We enrolled 97 patients (40 males, 57 females under treatment for hypertension between June 2006 and May 2007 in Shafa hospital, Kerman, Iran. BP was measured at clinic twice within 5-minute intervals. After setting up ambulatory blood pressure monitoring (ABPM, BP was measured at 30-minute intervals during the day and 60-minute intervals during the night. The frequency of increased BP (more than 140/90 mmHg was included in a regression model as dependent variable and all the others such as age, sex, body mass index (BMI, drugs and baseline clinical measurements as the predictors.    RESULTS: Increased BP was detected in 44% (95% CI: 38.79%-49.65% of all measurements during 24-hour monitoring. The frequency of increased BP had a significant relationship with BMI (b=0.35, P=0.001. Clinic's pulse pressure was a significant predicting factor for BP increase (P=0.02.    CONCLUSION: BMI and pulse pressure are the best predictors for being hypertensive during lifetime. Ineffective treatment of hypertension is frequent among the hypertensive patients.      Keywords: Blood pressure control, Pulse pressure, Ambulatory blood pressure monitoring (ABPM, BMI.

  9. Numerical prediction of car tire wear

    NARCIS (Netherlands)

    Lupker, H.A.; Cheli, F.; Braghin, F.; Gelosa, E.; Keckman, A.

    2004-01-01

    Due to their many economic and ecological implications, the possibility to predict tire wear is of major importance to tire manufacturers, fleet owners and governments. Based on these observations, in 2000, a three-year project named TROWS (Tire and Road Wear and Slip assessment was started. One of

  10. Rubber tire leachates in the aquatic environment.

    Science.gov (United States)

    Evans, J J

    1997-01-01

    Tires have a deleterious effect on the environment. This review discusses the background of scrap tires discarded in the environment, including tire composition, adverse environmental effects, threats to public health and safety, and solid waste management. Despite the widespread use of scrap tires in environmental applications, both land-based and aquatic, data on the indicators of environmental degradation are extremely scarce. Indicators of environmental degradation include analysis of chemicals within the water and sediment, analysis of contaminants within organisms, and analysis of the biological effects of these compounds on plants, animals, microbes, and organelles. Although these indicators are most useful when used in parallel, a review of the available information on chemical characterization of tire leachate from tire storage facilities, manufacturing, usage in recycling applications, and toxicity exposure studies, of vegetation surveys from waste tire areas and reviews of mammalian tire product toxicity, and of toxicity, mutagenicity, and carcinogenicity of tire exposure in experimental aquatic animals, microbes, and organelles is presented. The major characteristics of these studies are discussed in specific sections. The "Discussion and Conclusions" section discusses and summarizes the biological effects and chemical characterization of tire leachates. A global environmental perspective is included to improve our understanding of the deficiency of the current knowledge of tire leachate toxicity from various sources and to encourage interdisciplinary studies to establish the pattern of pollution associated with waste tire management.

  11. Characterizing Tire Crumb Rubber for Exposure Assessment

    Science.gov (United States)

    Tire crumb rubber derived from recycled tires is widely used as infill material in synthetic turf fields in the United States. An estimated 95% of the over 12,000 installed fields in the U.S. use tire crumb rubber infill alone or mixed with sand or alternative materials. Concerns...

  12. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  13. The Role of Central Blood Pressure Monitoring in the Management of Hypertension.

    Science.gov (United States)

    Ochoa, Adrian; Patarroyo-Aponte, Gabriel; Rahman, Mahboob

    2018-04-19

    Central blood pressure is a novel predictor of cardiovascular risk that can be measured in the clinical setting using currently available technology. This paper will review current available methods of central blood pressure monitoring as well as its impact in cardiac and renal disease. Both aortic and carotid systolic blood pressure are independently associated with cardiovascular mortality and serious cardiac events. Furthermore, studies show that systolic aortic blood pressure has been shown to be superior predictor of cardiovascular as compared to brachial blood pressure. Inhibitors of the renin angiotensin axis may have a beneficial effect on central blood pressure; however, long term studies evaluating the impact of lowering central blood pressure on clinical outcomes are lacking. Central blood pressure is a good predictor of cardiovascular risk. As more studies emerge demonstrating the value of central blood pressure as a therapeutic target, it is possible that targeting central blood pressure may become an important part of the armamentarium to lower cardiovascular risk.

  14. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  15. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  16. Drift velocity and pressure monitoring of the CMS muon drift chambers

    CERN Document Server

    Sonnenschein, Lars

    2010-01-01

    The drift velocity in drift tubes of the CMS muon chambers is a key parameter for the muon track reconstruction and trigger. It needs to be monitored precisely in order to detect any deviation from its nominal value. A change in absolute pressure, a variation of the gas admixture or a contamination of the chamber gas by air affect the drift velocity. Furthermore, the temperature and magnetic field influence its value. First data, taken with a dedicated Velocity Drift Chamber (VDC) built by RWTH Aachen IIIA are presented. Another important parameter to be monitored is the pressure inside the muon drift tube chambers because the drift velocity depends on it. Furthermore the differential pressure must not exceed a certain value and the absolute pressure has to be kept slightly above ambient pressure to prevent air from entering into the muon drift tube chambers in case of a leak. Latest pressure monitoring results are discussed.

  17. Pneumatic Tire Performance on Ice

    OpenAIRE

    Kishore Bhoopalam, Anudeep

    2015-01-01

    The evolution of vehicle safety systems, from the earliest brakes to today's accident avoidance systems, has led vehicles to have very high passenger safety. Driving on ice, though, still happens to be one of the driving conditions of low safety. A multitude of factors were identified by various studies to contribute to the complex frictional mechanism at the tire-ice interface. The tire is only force transmitting element of the vehicle, to the surface. Thus it is very essential to have in de...

  18. Energy requirements of tire pulling.

    Science.gov (United States)

    Fredriksen, Per M; Mamen, Asgeir

    2017-10-01

    We have investigated the effect using walking poles and pulling tires at 4 and 6 km·h-1 (1.11 and 1.67 m·s-1) speeds on oxygen uptake (V̇O2) and heart rate. Eleven subjects, 6 males, with a mean (SD) age of 25.2 (6.9) years participated in field tests involving walking without poles, walking with poles and tire pulling with poles. Increasing the load caused the largest increases in energy demand, more than 4 MET. Speed increase also caused substantial energy increase, approximately 4 MET. Increasing the inclination only modestly increased the oxygen uptake, approximately 2 MET. In both level walking and uphill walking, using poles marginally increased oxygen uptake compared to working without poles. Pulling one tire (12.5 kg) required an oxygen uptake of 27 (4) mL·kg-1·min-1 at 4 km·h-1 and 0% inclination. Adding one more tire (6 kg) drove the oxygen uptake further up to 39 (4) mL·kg-1·min-1. This is close to the requirement of level running at 10.5 km·h-1. Pulling both tires at 6 km·h-1 and 5% inclination required a V̇O2 of 54 (6) mL·kg-1·min-1, equal to running uphill at 5% inclination and 12.5 km·h-1 speed. Heart rate rose comparably with oxygen uptake. At 4 km·h-1 and 0% inclination the increase was 29 bpm, from 134 (21) to 163 (22) bpm when going from pulling one tire to two tires. In the hardest exercise, 6 km·h-1 and 5% inclination, heart rate reached 174 (14) bpm. The study showed that tire pulling even at slow speeds has an energy requirement that is so large that the activity may be feasible as endurance training.

  19. Measurement of whole tire profile

    Science.gov (United States)

    Yang, Yongyue; Jiao, Wenguang

    2010-08-01

    In this paper, a precision measuring device is developed for obtaining characteristic curve of tire profile and its geometric parameters. It consists of a laser displacement measurement unit, a closed-loop precision two-dimensional coordinate table, a step motor control system and a fast data acquisition and analysis system. Based on the laser trigonometry, a data map of tire profile and coordinate values of all points can be obtained through corresponding data transformation. This device has a compact structure, a convenient control, a simple hardware circuit design and a high measurement precision. Experimental results indicate that measurement precision can meet the customer accuracy requirement of +/-0.02 mm.

  20. Pressure Monitoring Using Hybrid fs/ps Rotational CARS

    Science.gov (United States)

    Kearney, Sean P.; Danehy, Paul M.

    2015-01-01

    We investigate the feasibility of gas-phase pressure measurements at kHz-rates using fs/ps rotational CARS. Femtosecond pump and Stokes pulses impulsively prepare a rotational Raman coherence, which is then probed by a high-energy 6-ps pulse introduced at a time delay from the Raman preparation. Rotational CARS spectra were recorded in N2 contained in a room-temperature gas cell for pressures from 0.1 to 3 atm and probe delays ranging from 10-330 ps. Using published self-broadened collisional linewidth data for N2, both the spectrally integrated coherence decay rate and the spectrally resolved decay were investigated as means for detecting pressure. Shot-averaged and single-laser-shot spectra were interrogated for pressure and the accuracy and precision as a function of probe delay and cell pressure are discussed. Single-shot measurement accuracies were within 0.1 to 6.5% when compared to a transducer values, while the precision was generally between 1% and 6% of measured pressure for probe delays of 200 ps or more, and better than 2% as the delay approached 300 ps. A byproduct of the pressure measurement is an independent but simultaneous measurement of the gas temperature.

  1. Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension.

    Science.gov (United States)

    Manning, Gillian; Donnelly, Richard

    2005-11-01

    Use of home blood-pressure monitoring is increasing but the technique and the equipment have limitations. We provide an overview of recent evidence in this rapidly evolving field. Home blood-pressure monitoring is an acceptable method for screening patients for hypertension. There is increasing evidence supporting the predictive power of home blood pressure for stroke risk even in the general population. The identification of white-coat and masked hypertension remains an important role for home blood-pressure monitoring. Unvalidated equipment and poor patient technique are major concerns. The purchase of devices needs to be linked to a simple patient-education programme, which is perhaps an opportunity for collaboration between healthcare providers and commercial companies. Devices that store the blood-pressure measurements in the memory are preferred to ensure accuracy of reporting. Data-transmission systems providing automatic storage, transmission and reporting of blood pressure, direct involvement of the patient and potentially a reduced number of hospital/general practitioner visits, offer significant advantages. To reduce patient anxiety, overuse of home blood-pressure monitoring should be avoided but there is the potential for self-modification of treatment, subject to certain safeguards. Self-monitoring of blood pressure is developing rapidly, linked to increasing awareness of the impact of reducing high blood pressure on public health and the marketing/advertising strategies used to sell automatic devices. Home blood-pressure monitoring has a role in the detection and management of blood pressure, but not at the expense of careful blood-pressure measurement in the office and adherence to national guidelines.

  2. Novel Approach for Ensuring Increased Validity in Home Blood Pressure Monitoring

    DEFF Research Database (Denmark)

    Wagner, Stefan Rahr; Toftegaard, Thomas Skjødeberg; Bertelsen, Olav Wedege

    This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure but with the devi......This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure...

  3. Data Of Daily Blood Pressure Monitoring In Patients With Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    A.P. Rebrov

    2009-06-01

    Full Text Available The aim of present work is to study the frequency of hypertension and the peculiarity of 24-hour blood pressure monitoring in patients with rheumatoid arthritis. We studied 584 patients with rheumatoid arthritis. Daily blood pressure monitoring was carried out in 46 patients with arthritis and 18 patients with essential hypertension. Frequency of hypertension was higher in patients with arthritis then in general population. Elevation of systolic blood pressure, heart rate and arterial blood pressure adequate decrease at night were developed to associate with advance of the disease.

  4. Zinc Leaching from Tire Crumb Rubber

    Science.gov (United States)

    Rhodes, E. P.; Ren, J.; Mays, D. C.

    2010-12-01

    Recent estimates indicate that more than 2 billion scrap tires are currently stockpiled in the United States and approximately 280 million more tires are added annually. Various engineering applications utilize recycled tires in the form of shredded tire crumb rubber. However, the use of tire crumb rubber may have negative environmental impacts, especially when the rubber comes into contact with water. A review of the literature indicates that leaching of zinc from tire crumb rubber is the most significant water quality concern associated with using this material. Zinc is generally used in tire manufacturing, representing approximately 1.3% of the final product by mass. This study will report results from the U.S. Environmental Protection Agency’s (EPA’s) Synthetic Precipitation Leaching Procedure, batch leaching tests, and column leaching tests performed to quantify the process by which zinc leaches from tire crumb rubber into water. Results are interpreted with a first-order kinetic attachment/detachment model, implemented with the U.S. Agricultural Research Service software HYDRUS-1D, in order to determine the circumstances when zinc leaching from tire crumb rubber would be expected to comply with the applicable discharge limits. One potential application for recycled tires is replacing sand with tire crumb rubber in granular media filters used for stormwater pollution control. For this to be a viable application, the total zinc in the stormwater discharge must be below the EPA’s benchmark value of 0.117 mg/L.

  5. A Strain-Based Method to Detect Tires’ Loss of Grip and Estimate Lateral Friction Coefficient from Experimental Data by Fuzzy Logic for Intelligent Tire Development

    Directory of Open Access Journals (Sweden)

    Jorge Yunta

    2018-02-01

    Full Text Available Tires are a key sub-system of vehicles that have a big responsibility for comfort, fuel consumption and traffic safety. However, current tires are just passive rubber elements which do not contribute actively to improve the driving experience or vehicle safety. The lack of information from the tire during driving gives cause for developing an intelligent tire. Therefore, the aim of the intelligent tire is to monitor tire working conditions in real-time, providing useful information to other systems and becoming an active system. In this paper, tire tread deformation is measured to provide a strong experimental base with different experiments and test results by means of a tire fitted with sensors. Tests under different working conditions such as vertical load or slip angle have been carried out with an indoor tire test rig. The experimental data analysis shows the strong relation that exists between lateral force and the maximum tensile and compressive strain peaks when the tire is not working at the limit of grip. In the last section, an estimation system from experimental data has been developed and implemented in Simulink to show the potential of strain sensors for developing intelligent tire systems, obtaining as major results a signal to detect tire’s loss of grip and estimations of the lateral friction coefficient.

  6. Negative-Pressure Hydrocephalus: A Case Report on Successful Treatment Under Intracranial Pressure Monitoring with Bilateral Ventriculoperitoneal Shunts.

    Science.gov (United States)

    Pandey, Sajan; Jin, Yi; Gao, Liang; Zhou, Cheng Cheng; Cui, Da Ming

    2017-03-01

    Negative-pressure hydrocephalus (NegPH), a very rare condition of unknown etiology and optimal treatment, usually presents postneurosurgery with clinical and imaging features of hydrocephalus, but with negative cerebrospinal fluid pressure. We describe a NegPH case of -3 mm Hg intracranial pressure that was successfully treated to achieve 5 mm Hg under continuous intracranial pressure monitoring with horizontal positioning, head down and legs elevated to 10°-15°, neck wrapping for controlled venous drainage, chest and abdomen bandages, infusion of 5% dextrose fluid to lower plasma osmolarity (Na + , 130-135 mmol/L), daily cerebrospinal fluid drainage >200 mL, and arterial blood gas partial pressure of carbon dioxide >40 mm Hg. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Packaged Capacitive Pressure Sensor System for Aircraft Engine Health Monitoring

    Science.gov (United States)

    Scardelletti, Maximilian C.; Zorman, Christian A.

    2016-01-01

    This paper describes the development of a packaged silicon carbide (SiC) based MEMS pressure sensor system designed specifically for a conventional turbofan engine. The electronic circuit is based on a Clapp-type oscillator that incorporates a 6H-SiC MESFET, a SiCN MEMS capacitive pressure sensor, titanate MIM capacitors, wirewound inductors, and thick film resistors. The pressure sensor serves as the capacitor in the LC tank circuit, thereby linking pressure to the resonant frequency of the oscillator. The oscillator and DC bias circuitry were fabricated on an alumina substrate and secured inside a metal housing. The packaged sensing system reliably operates at 0 to 350 psi and 25 to 540C. The system has a pressure sensitivity of 6.8 x 10E-2 MHzpsi. The packaged system shows negligible difference in frequency response between 25 and 400C. The fully packaged sensor passed standard benchtop acceptance tests and was evaluated on a flight-worthy engine.

  8. Technology updates from the OEMs (tires, rims, automation inflation systems, and alternative fuels for heavy vehicles)

    Energy Technology Data Exchange (ETDEWEB)

    White, N. [Charonic Canada Inc., Ottawa, ON (Canada)

    2001-07-01

    This power point presentation outlined a project at Charonic Canada Inc., which demonstrated and evaluated innovations in the areas of vehicle safety, operating economy and diesel fuel substitution. It also presented a range of results that demonstrate some of the trends that may be used on vehicles, particularly trucks, in the near future. The demonstration involved a 2 year observation of a five truck fleet hauling refuse from Toronto to Michigan. The trucks completed 2,500 round trips of 540 miles and used 115 tonnes of natural gas fuel replacing diesel fuel. Safety innovations included tire pressure monitoring, hazard locator radar system, anti-spray system, wheel nut and bearing temperature indicators and brake safe indicators. These features were reported as being worthwhile investments. Economy innovations included a dual-fuel engine system, wide base tires, light weight CNG tanks, centrifugal oil cleaner and an oil and lubrication system. Although the technology continues to improve, the dual-engine system requires further work. Difficulties were encountered when trying to meet performance, fuel economy and emission targets at the same time. 18 figs.

  9. High Value Scrap Tire Recycle

    Energy Technology Data Exchange (ETDEWEB)

    Bauman, B. D.

    2003-02-01

    The objectives of this project were to further develop and scale-up a novel technology for reuse of scrap tire rubber, to identify and develop end uses for the technology (products), and to characterize the technology's energy savings and environmental impact.

  10. Influence of Tire Characteristics of Interurban Taxis on Exposure Level to Drivers Whole-Body Vibrations

    Directory of Open Access Journals (Sweden)

    Milad Derakhshanjazari

    2016-03-01

    Full Text Available Introduction: Taxi drivers’ exposure to repeat whole-body vibrations can cause back pain and digestive disorders. Since this type of vibration depends on the car components, this study was carried out to determine the influence of tire characteristics on the amount of whole-body vibrations transmitted to the Peugeot 405 taxi drivers. Methods: In this experimental study, vibration characteristics were measured according to the ISO2631-1 with each of the statuses: tubeless tires fixed and fluid in it (normal air or nitrogen and also the fluid in the tires fixed with tubes or tubeless on asphalt-paved road. Other variables including tire pressure, engine speed, road gradient, number of passengers, springs, and shock absorbers were kept constant. Then the effect of changes was analyzed using an appropriate statistical test. Results: After changing nitrogen to normal air and tubeless tires to tube, the average of RMS in Z-axis, eight-hour equivalent acceleration A(8 and crest factor were reduced (P 0.9 m/s2 to caution zone (0.45-0.9 m/s2 with a value of 0.8 m/s2. Conclusions: The amount of vibration transmitted to the whole body is sensitive to existence of tubes and tires inflation so that we can reduce the amount of whole-body vibration to lower than the upper limit of the health risk by changing the characteristics of the tire

  11. Automobile tires--a potential source of highly carcinogenic dibenzopyrenes to the environment.

    Science.gov (United States)

    Sadiktsis, Ioannis; Bergvall, Christoffer; Johansson, Christer; Westerholm, Roger

    2012-03-20

    Eight tires were analyzed for 15 high molecular weight (HMW) polycyclic aromatic hydrocarbons (PAH), using pressurized fluid extraction. The variability of the PAH concentrations determined between different tires was large; a factor of 22.6 between the lowest and the highest. The relative abundance of the analytes was quite similar regardless of tire. Almost all (92.3%) of the total extractable PAH content was attributed to five PAHs: benzo[ghi]perylene, coronene, indeno[1,2,3-cd]pyrene, benzo[e]pyrene, and benzo[a]pyrene. The difference in the measured PAH content between summer and winter tires varied substantially across manufacturers, making estimates of total vehicle fleet emissions very uncertain. However, when comparing different types of tires from the same manufacturer they had significantly (p = 0.05) different PAH content. Previously, there have been no data available for carcinogenic dibenzopyrene isomers in automobile tires. In this study, the four dibenzopyrene isomers dibenzo[a,l]pyrene, dibenzo[a,e]pyrene, dibenzo[a,i]pyrene, and dibenzo[a,h]pyrene constituted tires may be a potential previously unknown source of carcinogenic dibenzopyrenes to the environment.

  12. Containment pressure monitoring method after severe accident in nuclear power plant

    International Nuclear Information System (INIS)

    Luo Chuanjie; Zhang Shishui

    2011-01-01

    The containment atmosphere monitoring system in nuclear power plant was designed on the basis of design accident. But containment pressure will increase greatly in a severe accident, and pressure instrument in the containment can't satisfy the monitoring requirement. A new method to monitor the pressure change in the containment after a severe accident was considered, through which accident soften methods can be adopted. Under present technical condition, adding a pressure monitoring channel out of containment for post-severe accident is a considerable method. Daya Bay Nuclear Power Plant implemented this modification, by which the containment release time can be delayed during severe accident, and nuclear safety can be increased. After analysis, this method is safe and feasible. (authors)

  13. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  14. Drift velocity and pressure monitoring of the CMS muon drift chambers

    CERN Document Server

    Sonnenschein, Lars

    2011-01-01

    The drift velocity in drift tubes of the CMS muon chambers is a key parameter for the muon track reconstruction and trigger. It needs to be monitored precisely in order to detect any deviation from its nominal value. A change in absolute pressure, a variation of the gas admixture or a contamination of the chamber gas by air affect the drift velocity. Furthermore, the temperature and magnetic field influence its value. First data, taken with a dedicated Velocity Drift Chamber (VDC) built by RWTH Aachen IIIA are presented. Another important parameter to be monitored is the pressure inside the muon drift tube chambers. The differential pressure must not exceed a certain value and the absolute pressure has to be kept slightly above ambient pressure to prevent air from entering into the muon drift tube chambers in case of a leak. Latest drift velocity monitoring results are discussed.

  15. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  16. On preventive blood pressure self-monitoring at home

    DEFF Research Database (Denmark)

    Verdezoto, Nervo; Grönvall, Erik

    2015-01-01

    for self-measuring, the importance of interpretation, understanding and health awareness, sharing self-monitoring information for prevention, various motivational factors, the role of the doctor in prevention, and the home as a distributed information space. An awareness of these aspects can help designers......, to understand existing challenges, and uncover opportunities for self-monitoring technologies to support preventive healthcare activities among older adults. From our study, several important aspects emerged to consider when designing preventive self-monitoring technology, such as the complexity of guidelines...... how these aspects can both inform people engaged in Quantified Self activities and designers alike, and the tools and approaches that have sprung from the so-called Quantified Self movement...

  17. Evaluation of the monitor cursor-line method for measuring pulmonary artery and central venous pressures.

    Science.gov (United States)

    Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary

    2010-11-01

    To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.

  18. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  19. Model-Based, Noninvasive Monitoring of Intracranial Pressure

    Science.gov (United States)

    2013-07-01

    vasoactive medication drip rates and ventilator settings, nursing progress notes, discharge summaries, radiology reports, provider order entry data...the interaction of intracranial pressure and cerebral hemodynamics . Journal of Applied Physiology 82(4):1256-1269, 1997. [5] M Saeed, M Villarroel, AT

  20. Development of an electronic manometer for intrapleural pressure monitoring.

    Science.gov (United States)

    Krenke, Rafał; Guć, Maciej; Grabczak, Elżbieta Magdalena; Michnikowski, Marcin; Pałko, Krzysztof Jakub; Chazan, Ryszarda; Gólczewski, Tomasz

    2011-01-01

    Measurement of intrapleural pressure is useful during various pleural procedures. However, a pleural manometer is rarely available. The aim of this study was to (1) construct an electronic pleural manometer, (2) assess the accuracy of the measurements done with the new device, (3) calculate the costs of the manometer construction and (4) perform an initial evaluation of the device in a clinical setting. Only widely accessible elements were used to construct the device. A vascular pressure transducer was used to transform pressure into an electronic signal. Reliability of the measurements was evaluated in a laboratory setting in a prospective, single-blind manner by comparing the results with those measured by a water manometer. Functionality of the device was assessed during therapeutic thoracentesis. The cost of the new pleural manometer was calculated. We built a small, portable device which can precisely measure intrapleural pressure. The measurement results showed very high agreement with those registered with a water manometer (r = 0.999; p electronic manometer during therapeutic thoracentesis showed it was easy to use. The total time needed for 6 measurements after withdrawal of different volumes of pleural fluid in 1 patient did not exceed 6 min. The total cost of the device was calculated to be electronic pleural manometer at modest costs. The device is easy to use and enables data display and storage in the personal computer. Copyright © 2011 S. Karger AG, Basel.

  1. Vibration monitoring of pressure vessel in Atucha-1 power plant

    International Nuclear Information System (INIS)

    Belinco, C.; Pastorini, A.; Martin Ghiselli, A.; Sacchi, M.

    1994-01-01

    The Vibration Monitoring Systems are described to obtain information about the mechanical state of different components in the main coolant system of nuclear power plants to ensure that changes in the mechanical integrity of this components are detected at an early point in time, even during operation. 9 figs

  2. 49 CFR 230.113 - Wheels and tire defects.

    Science.gov (United States)

    2010-10-01

    ... tires may not have a seam running lengthwise that is within 33/4 inches of the flange. (g) Worn flanges... 49 Transportation 4 2010-10-01 2010-10-01 false Wheels and tire defects. 230.113 Section 230.113... Tenders Wheels and Tires § 230.113 Wheels and tire defects. Steam locomotive and tender wheels or tires...

  3. Model-based state estimator for an intelligent tire

    NARCIS (Netherlands)

    Goos, J.; Teerhuis, A. P.; Schmeitz, A. J.C.; Besselink, I.; Nijmeijer, H.

    2017-01-01

    In this work a Tire State Estimator (TSE) is developed and validated using data from a tri-axial accelerometer, installed at the inner liner of the tire. The Flexible Ring Tire (FRT) model is proposed to calculate the tire deformation. For a rolling tire, this deformation is transformed into

  4. Model-based State Estimator for an Intelligent Tire

    NARCIS (Netherlands)

    Goos, J.; Teerhuis, A.P.; Schmeitz, A.J.C.; Besselink, I.J.M.; Nijmeijer, H.

    2016-01-01

    In this work a Tire State Estimator (TSE) is developed and validated using data from a tri-axial accelerometer, installed at the inner liner of the tire. The Flexible Ring Tire (FRT) model is proposed to calculate the tire deformation. For a rolling tire, this deformation is transformed into

  5. Self-monitoring of blood pressure during pregnancy

    DEFF Research Database (Denmark)

    Lihme, Frederikke F; Madsen, Mette E; Lykke, Jacob A

    2017-01-01

    arterial blood pressure (MAP) and were compared using the paired sample t-test. Mean values and differences of systolic and diastolic pressure were plotted in Bland-Altman plots to test the agreement of the measurements. Finally, a mean evaluation score was calculated. RESULTS: One hundred pregnant women...... and instructed each participant in correct measurement and then took three measurements on both arms. The participant then repeated the measurements and filled an evaluation questionnaire. We used a validated semiautomatic device for all measurements. Mean values were calculated for systolic, diastolic and mean...... were included in the study. Mean values of systolic, diastolic and MAP were 110.6, 69.7 and 83.3 mmHg, respectively, as assessed by the hospital staff. The corresponding self-measurements were 111.4, 70.2 and 83.9 mmHg, respectively. Mean differences between hospital and self-measurements were 0.79 mm...

  6. High-Performance Pressure Sensor for Monitoring Mechanical Vibration and Air Pressure

    Directory of Open Access Journals (Sweden)

    Yancheng Meng

    2018-05-01

    Full Text Available To realize the practical applications of flexible pressure sensors, the high performance (sensitivity and response time as well as more functionalities are highly desired. In this work, we fabricated a piezoresistive pressure sensor based on the micro-structured composites films of multi-walled carbon nanotubes (MWCNTs and poly (dimethylsiloxane (PDMS. In addition, we establish efficient strategies to improve key performance of our pressure sensor. Its sensitivity is improved up to 474.13 kPa−1 by minimizing pressure independent resistance of sensor, and response time is shorten as small as 2 μs by enhancing the elastic modulus of polymer elastomer. Benefiting from the high performance, the functionalities of sensors are successfully extended to the accurate detection of high frequency mechanical vibration (~300 Hz and large range of air pressure (6–101 kPa, both of which are not achieved before.

  7. Bitumen pressure cell installation and monitoring procedure: Draft

    International Nuclear Information System (INIS)

    1987-02-01

    A 6-in. (150-mm)-thick bitumen layer will be placed between the upper shaft preliminary concrete lining and the steel lining component of the final lining. The function of this layer is twofold; first, it will act as a compliant sealing layer which, because of the bitumen's fluid properties, will remain effective even if the concrete and steel lining components suffer significant strains; and second, it will help to ensure a uniform transmission of rock or hydrostatic loads to the inner lining components. A type 200--300 penetration grade bitumen (ASTM D946) will be used, with 32% by weight of added limestone flour. The purpose of the limestone flour is to ensure that the bitumen has a density which is greater than that of the formation fluids, resulting in a positive pressure gradient from the bitumen to the ground water. The resulting mixture will have a specific gravity of about 1.25 at 60/degree/F (15/degree/C). Pressure measurements in the bitumen layer are needed in order to determine loads on the inner lining components. Although some initial loading will occur in response to excavation, full rock and hydrostatic loads will not develop until post-construction thawing of the freeze wall is complete. Loads transmitted by the bitumen layer to the other lining components will be those which act radially, i.e., the bitustatic pressure, or the radial stress if deviatoric stresses develop

  8. Ambulatory blood pressure monitoring in daily clinical practice - the Spanish ABPM Registry experience.

    Science.gov (United States)

    Gorostidi, Manuel; Banegas, José R; de la Sierra, Alejandro; Vinyoles, Ernest; Segura, Julián; Ruilope, Luis M

    2016-01-01

    Many patients are hypertensive at the medical settings but show normal blood pressure out of the doctor's office, and are classified as white-coat hypertensives. On the other hand, many patients with controlled hypertension at the clinic show ambulatory blood pressure levels above the thresholds considered for an adequate blood pressure control, known as having masked hypertension. Using data from the Spanish Ambulatory Blood Pressure Monitoring Registry (Spanish ABPM Registry), a national program developed to promote the use of the ambulatory technique for hypertension management in daily practice, we have reviewed the main strengths of this approach, that is the ability to detect discrepancies of blood pressure status with respect to office blood pressure measurement, and to better assess accurate rates of hypertension control. White-coat hypertension within patients with elevated office blood pressure, and masked hypertension within office-controlled patients affected one of three patients in each office status. On the other hand, rates of ambulatory blood pressure control (50%) doubled those of office blood pressure control (25%), still remaining half the patients uncontrolled. We think that a systematic use of ambulatory blood pressure monitoring, and strategies to improve blood pressure control constitute key priorities in hypertension management. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  9. Cable condition monitoring in a pressurized water reactor environment

    International Nuclear Information System (INIS)

    Al-Hussaini, T.J.

    1988-01-01

    Oconee Nuclear Station is the first nuclear plant designed, engineered and constructed by Duke Power Company. Even though the accelerated aging method was available to determine the life expectancy of the cable used in the reactor building, no natural aging data was available at that time. In order to be able to verify the condition of the reactor building cable over the life of the plant, an on-going cable monitoring plan was instituted. Various types of cable were selected to be monitored, and they were installed in cable life evaluation circuits in the reactor building. At five year intervals over the life of the plant, cable samples would be removed from these cable life evaluation circuits and tested to determine the effects of the reactor building environment on the integrity of the cable. A review of the cable life evaluation circuits and the results of the evaluation program to date is presented

  10. Making ambulatory blood pressure monitoring accessible in pharmacies.

    Science.gov (United States)

    James, Kirstyn; Dolan, Eamon; O'Brien, Eoin

    2014-06-01

    Ambulatory blood pressure measurement (ABPM), although recommended for the diagnosis and management of hypertension, has limited availability. The objective of this study was to show that if the characteristics of patients attending pharmacies for ABPM are similar to those attending primary care, the technique can be made more widely available to patients through pharmacies. A comparative study using a software program that allowed central collection, analysis and comparison of ABPM data from patients attending primary care and pharmacies for assessment of hypertension in Ireland. ABPM data from 46 978 patients attending primary care were compared with 1698 attending pharmacies between 2007 and 2013. The age, sex and blood pressure characteristics of patients attending primary care and pharmacies were similar. The mean pressures in all categories, except for systolic blood pressure recorded in primary care, were higher in men. The first ABPM measurements recorded in pharmacies were slightly higher than those in primary care (150.8 ± 19.5/88.7 ± 13.7 vs. 149.6 ± 20.7/88.0 ± 14.4 mmHg). More patients attending primary care were normotensive than those attending pharmacies (19.5 vs. 16.4%), whereas more patients attending pharmacies were hypertensive than those attending primary care (62.8 vs. 60.7%), particularly female patients (61.0 vs. 56.4%). White-coat hypertension was similar in patients attending primary care and pharmacies (19.8 vs. 20.8%), but it was more prevalent in men attending pharmacies (22.0 vs. 17.4%) and in women attending primary care (21.9 vs. 19.7%). There were more dippers in pharmacy then primary care ABPMs (84.7 vs. 79.4%). A preference for having ABPM on Fridays and Saturdays was evident in patients attending pharmacies (19.6 vs. 6.6%), whereas there was a preference for early morning recording in primary care (4.1 vs. 1.1%). This study, which is the first to report on ABPM data from the pharmacy setting, shows that the blood pressure

  11. Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring.

    Science.gov (United States)

    Schwartz, Gregor; Tee, Benjamin C-K; Mei, Jianguo; Appleton, Anthony L; Kim, Do Hwan; Wang, Huiliang; Bao, Zhenan

    2013-01-01

    Flexible pressure sensors are essential parts of an electronic skin to allow future biomedical prostheses and robots to naturally interact with humans and the environment. Mobile biomonitoring in long-term medical diagnostics is another attractive application for these sensors. Here we report the fabrication of flexible pressure-sensitive organic thin film transistors with a maximum sensitivity of 8.4 kPa(-1), a fast response time of 15,000 cycles and a low power consumption of monitoring, which may lead to the use of flexible pressure sensors in mobile health monitoring and remote diagnostics in cardiovascular medicine.

  12. Performance of an aircraft tire under cyclic braking and of a currently operational antiskid braking system

    Science.gov (United States)

    Tanner, J. A.

    1972-01-01

    An experimental investigation was conducted to study the performance of an aircraft tire under cyclic braking conditions and to study the performance of a currently operational aircraft antiskid braking system. Dry, damp, and flooded runway surface conditions were used in the investigation. The results indicated that under cyclic braking conditions the braking and cornering-force friction coefficients may be influenced by fluctuations in the vertical load, flexibility in the wheel support, and the spring coupling between the wheel and the tire-pavement interface. The cornering capability was shown to be negligible at wheel slip ratios well below a locked-wheel skid under all test surface conditions. The maximum available brake-force friction coefficient was shown to be dependent upon the runway surface condition, upon velocity, and, for wet runways, upon tire differences. Moderate reductions in vertical load and brake system pressure did not significantly affect the overall wet-runway performance of the tire.

  13. Improving management and effectiveness of home blood pressure monitoring: a qualitative UK primary care study.

    Science.gov (United States)

    Grant, Sabrina; Greenfield, Sheila M; Nouwen, Arie; McManus, Richard J

    2015-11-01

    Self-monitoring blood pressure (SMBP) is becoming an increasingly prevalent practice in UK primary care, yet there remains little conceptual understanding of why patients with hypertension engage in self-monitoring. To identify psychological factors or processes prompting the decision to self-monitor blood pressure. A qualitative study of patients previously participating in a survey study about SMBP from four general practices in the West Midlands. Taped and transcribed in-depth interviews with 16 patients (6 currently monitoring, 2 used to self-monitor, and 8 had never self-monitored). Thematic analysis was undertaken. Three main themes emerged: 'self' and 'living with hypertension' described the emotional element of living with an asymptomatic condition; 'self-monitoring behaviour and medication' described overall views about self-monitoring, current practice, reasons for monitoring, and the impact on medication adherence; and 'the GP-patient transaction' described the power relations affecting decisions to self-monitor. Self-monitoring was performed by some as a protective tool against the fears of a silent but serious condition, whereas others self-monitor simply out of curiosity. People who self-monitored tended not to discuss this with their nurse or GP, partly due to perceiving minimal or no interest from their clinician about home monitoring, and partly due to fear of being prescribed additional medication. The decision to self-monitor appeared often to be an individual choice with no schedule or systems to integrate it with other medical care. Better recognition by clinicians that patients are self-monitoring, perhaps utilising the results in shared decision-making, might help integrate it into daily practice. © British Journal of General Practice 2015.

  14. Simple Models for the Dynamic Modeling of Rotating Tires

    Directory of Open Access Journals (Sweden)

    J.C. Delamotte

    2008-01-01

    Full Text Available Large Finite Element (FE models of tires are currently used to predict low frequency behavior and to obtain dynamic model coefficients used in multi-body models for riding and comfort. However, to predict higher frequency behavior, which may explain irregular wear, critical rotating speeds and noise radiation, FE models are not practical. Detailed FE models are not adequate for optimization and uncertainty predictions either, as in such applications the dynamic solution must be computed a number of times. Therefore, there is a need for simpler models that can capture the physics of the tire and be used to compute the dynamic response with a low computational cost. In this paper, the spectral (or continuous element approach is used to derive such a model. A circular beam spectral element that takes into account the string effect is derived, and a method to simulate the response to a rotating force is implemented in the frequency domain. The behavior of a circular ring under different internal pressures is investigated using modal and frequency/wavenumber representations. Experimental results obtained with a real untreaded truck tire are presented and qualitatively compared with the simple model predictions with good agreement. No attempt is made to obtain equivalent parameters for the simple model from the real tire results. On the other hand, the simple model fails to represent the correct variation of the quotient of the natural frequency by the number of circumferential wavelengths with the mode count. Nevertheless, some important features of the real tire dynamic behavior, such as the generation of standing waves and part of the frequency/wavenumber behavior, can be investigated using the proposed simplified model.

  15. Remote communications technology redefines integrity verification and monitoring of low pressure isolation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-01-15

    In 2007, a ship collided with the southeast face of a satellite platform jacket in the North Sea, damaging the 12-inch export riser. Emergency shutdown valves immediately shut-in production from the platform, leaving the pressure in the pipeline at approximately 4 barg. The riser had to be repaired before production could resume. TDW Offshore Services (TDW) was hired to develop a low pressure solution to isolate the damaged section of the pipeline riser from the export pipeline gas inventory. TDW used its range of specialist pipeline pigging, pig tracking and remote communications technology to solve the problem. The solution consisted of a custom-designed TDW pig trap and pigging spread; a high friction pig train furnished with the SmartTrack remote tracking and pressure-monitoring system; a SmartTrack subsea remote tracking and pressure-monitoring system; a SmartTrack topside tracking and monitoring system with radio link to the dive support vessel; and a pipeline isolation ball valve. TDW was able to monitor the downstream pressure of each isolation pig continuously throughout the operation using its innovative technology that sends isolation integrity data by radio link to a dive support vessel through pipe wall communications. The use of remote tracking and pressure monitoring technology enabled TDW to make repairs to the damaged riser while maintaining a continuous flow throughout the duration of the operation. 4 figs.

  16. Smart monitoring of fluid intake and bladder voiding using pressure sensitive mats.

    Science.gov (United States)

    Cohen-McFarlane, Madison; Green, James R; Knoefel, Frank; Goubran, Rafik

    2016-08-01

    Pressure sensitive mats have been used in noninvasive smart monitoring for a variety of problems including breathing rate monitoring, sleep monitoring, mobility, and weight. This paper describes a proof of concept application of pressure mats to monitor fluid intake/output (fluid cycle) events during the night. The ability to more accurately track such events has potential implications for monitoring those individuals who have nocturia, a condition where a person wakes at night to urinate. Data were collected from a healthy young female subject instructed to drink as much water as was comfortable (700mL) and lie in a supine position on a mattress located directly on three pressure mats. This was compared to an initial data set collected immediately after voiding but before drinking, 30 minutes after drinking, 60 minutes after drinking and a final data set after again voiding the bladder. The additional pressure from the 700mL of water was detectible and tracked over the course of the hour-long testing session under idealized conditions. This provides a proof-of-concept that nocturnal fluid intake and bladder voiding events can be tracked using non-invasive pressure-sensitive mats, however additional testing and development is required to achieve a deployable monitoring system.

  17. Tire inspection machine presenting an X-ray image of the entire width of the tire

    International Nuclear Information System (INIS)

    1975-01-01

    An X-ray machine for production line inspection of tires places each tire in turn with one sector of the tire inside of a U-shaped arrangement of three fluorescent screens so that one screen faces the tread and the other two face the sides of the tire. An X-ray source inside the bead circle of the tire produces X-ray shadow pictures on the screens, which are separately viewed by a video camera, with an image of the picture on each screen transferred to a third of the target of a storage tube, so that a composite image of the entire width of the tire sector can be displayed on a picture tube. The tire is rotated step-wise for display of still pictures of every sector of the tire. (Auth.)

  18. Research and application of online measurement system of tire tread profile in automobile tire production

    Science.gov (United States)

    Wang, Pengyao; Chen, Xiangguang; Yang, Kai; Liu, Xuejiao

    2017-01-01

    To improve the measuring efficiency of width and thickness of tire tread in the process of automobile tire production, the actual condition for the tire production process is analyzed, and a fast online measurement system based on moving tire tread of tire specifications is established in this paper. The coordinate data of tire tread profile is acquired by 3D laser sensor, and we use C# language for programming which is an object-oriented programming language to complete the development of client program. The system with laser sensor can provide real-time display of tire tread profile and the data to require in the process of tire production. Experimental results demonstrate that the measuring precision of the system is <= 1mm, it can meet the measurement requirements of the production process, and the system has the characteristics of convenient installation and testing, system stable operation.

  19. Tactile shoe inlays for high speed pressure monitoring

    DEFF Research Database (Denmark)

    Drimus, Alin; Mátéfi-Tempfli, Stefan

    2015-01-01

    This work describes the development of flexible tactile sensor shoe inlays for humanoid robots. Their design is based on a sandwich structure of flexible layers with a thin sheet of piezoresistive rubber as main transducer element. The layout and patterning of top and bottom electrodes give 1024...... pressure sensitive cells and the use of high speed electronics and multiplexing algorithms provides frame rates of 100 Hz. The sensors tolerate overloads while showing a consistent output. The developed prototypes show a high potential not only for robotics, but also for use in sensorised human prosthetics....

  20. Role of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Hypertension, a common cardiovascular disease (CVD) risk factor, is usually diagnosed and treated based on blood pressure readings obtained in the clinic setting. Blood pressure may differ considerably when measured in the clinic versus outside of the clinic setting. Over the past several decades, evidence has accumulated on two approaches for measuring out-of-clinic blood pressure: ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring (HBPM). Blood pressure measures on ABPM and HBPM each have a stronger association with CVD outcomes than clinic blood pressure. Controversy exists whether ABPM or HBPM is superior for estimating CVD risk, and under what circumstances these methods should be used in clinical practice for assessing out-of-clinic blood pressure. This review describes ABPM and HBPM procedures, the blood pressure phenotypic measures that can be ascertained, and the evidence that supports the use of each approach to measure out-of-clinic blood pressure. This review also describes barriers to the successful implementation of ABPM and HBPM in clinical practice, proposes core competencies for the conduct of these procedures, and highlights important areas for future research. PMID:26457954

  1. “A System for Automatically Maintaining Pressure in a Commercial Truck Tire”

    Energy Technology Data Exchange (ETDEWEB)

    Maloney, John [The Goodyear Tire and Rubber Company, Akron, OH (United States)

    2017-07-07

    Under-inflated tires significantly reduce a vehicle’s fuel efficiency by increasing rolling resistance (drag force). The Air Maintenance Technology (“AMT”) system developed through this project replenishes lost air and maintains optimal tire cavity pressure whenever the tire is rolling in service, thus improving overall fuel economy by reducing the tire’s rolling resistance. The system consists of an inlet air filter, an air pump driven by tire deformation during rotation, and a pressure regulating device. Pressurized air in the tire cavity naturally escapes by diffusion through the tire and wheel, leaks in tire seating, and through the filler valve and its seating. As a result, tires require constant maintenance to replenish lost air. Since manual tire inflation maintenance is both labor intensive and time consuming, it is frequently overlooked or ignored. By automating the maintenance of optimal tire pressure, the tire’s contribution to the vehicle’s overall fuel economy can be maximized. The work was divided into three phases. The objectives of Phase 1, Planning and Initial Design, resulted in an effective project plan and to create a baseline design. The objectives for Phase 2, Design and Process Optimization, were: to identify finalized design for the pump, regulator and filter components; identify a process to build prototype tires; assemble prototype tires; test prototype tires and document results. The objectives of Phase 3, Design Release and Industrialization, were to finalize system tire assembly, perform release testing and industrialize the assembly process.

  2. Stochastic model to monitor mechanical vibrations in pressurized water reactors

    International Nuclear Information System (INIS)

    Shieh, D.J.; Upadhyaya, B.R.

    1984-01-01

    The feasibility of using neutron flux and core-exit temperature signals in PWRs for estimating core coolant flow velocity has been demonstrated using normal operational data from both the LOFT reactor and a commerical PWR. The LOFT analysis further showed that the core coolant velocity can be accurately monitored for various flow rates using the linear phase-frequency relationship in the frequency range 0.1 to 2 Hz. The development of the technique for monitoring core coolant velocity in PWRs provides a valuable alternative for flow measurement. Theoretical studies of core heat transfer in PWRs showed that the fluctuating heat sources have a dominating effect on the core-exit temperature compared to fluctuations of the coolant flow rate and core inlet coolant temperature. In the present analysis a detailed distributed parameter model of a PWR core was developed with the purpose of studying the following aspects of core coolant flow rate measurement: the mechanisms causing linear phase relationship between neutron flux and coolant temperature signals due to various perturbation sources; the effect of axial flux shape on the phase slope (or estimated transit delay time); and the relationship between transit delay time and effective distance of temperature noise propagation to maintain the flow velocity invariant

  3. Directions for material recovery of used tires and their use in the production of new products intended for the industry of civil construction and pavements

    Science.gov (United States)

    Bulei, C.; Todor, M. P.; Heput, T.; Kiss, I.

    2018-01-01

    The management of waste from used tires is one of the major principles of recycling and reuse, which involves encouraging a high level of material recovery components, preferably by recycling. Given the current pressure on natural resources on a global scale we must fully take into account the waste in a broader framework defined by the flow of raw materials and their sustainable use. Thus, the opportunity to use various waste from used tires as raw material in order to support economic activities becomes a priority. The recycling of raw materials from waste products and their use in new production processes for their material capitalization is becoming a sustainable approach. Used tire recycling, is the process of recycling waste tires that are no longer suitable for use on vehicles due to wear or irreparable damage. These tires are a problematic source of waste, due to the large volume produced, the durability of the tires, and the components in the tire that are ecologically problematic. Although tires are usually burnt, not recycled, efforts are continuing to find value. Tires can be recycled into, among other things, typically as crumb rubber modifier in recycled pavement. The paper presents aspects of the product resulting from crushing of used tires (powder), which can be used properly valued in the street furniture field or building materials containing rubber.

  4. Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?

    Science.gov (United States)

    Nobre, Fernando; Mion, Décio

    2005-10-01

    Ambulatory blood pressure monitoring (ABPM) provides relevant data about blood pressure over a 24-h period. The analysis of parameters to determine the blood pressure profile from these data is of great importance. To calculate areas under systolic and diastolic blood pressure curves (SBP-AUC/DBP-AUC) and compare with systolic and diastolic blood pressure load (SBPL/DBPL) and 24-h systolic and diastolic blood pressure (24-h SBP/24-h DBP) in order to determine which provides the best correlation with left ventricular mass index (LVMI). ABPM measurements (1143 individuals) were analyzed to obtain 24-h SBP/24-h DBP, SBPL/DBPL, and SBP-AUC/ DBP-AUC, using Spacelabs (90207) and CardioSistemas devices. Left ventricular mass was determined using an echocardiograph HP Sonos 5500 and LVMI was calculated. The correlations between all possible pairs within the group 24-h SBP/SBPL/SBP-AUC and 24-h DBP/DBPL/DBP-AUC were high and statistically significant. The correlations between 24-h SBP/24-h DBP and SBP-AUC/DBP-AUC with SBPL/DBPL close to 100%, were lower than those mentioned above. The correlations of the parameters obtained by ABPM with LVMI were also high and statistically significant, except for blood pressure load between 90 and 100%, and for 24-h SBP of 135 mmHg or less and SBPL higher than 50%. SBPL/DBPL and SBP-AUC/DBP-AUC can be used for the evaluation of ABPM data owing to the strong correlation with 24-h SBP/24-h DBP and with LVMI, except when SBPL is close to 100% or 24-h SBP is below 135 mmHg but SBPL is above 50%. SBP-AUC/DBP-AUC, however, are a better alternative because they do not have the limitations of blood pressure load or even of 24-h blood pressure present.

  5. Choking under social pressure: social monitoring among the lonely.

    Science.gov (United States)

    Knowles, Megan L; Lucas, Gale M; Baumeister, Roy F; Gardner, Wendi L

    2015-06-01

    Lonely individuals may decode social cues well but have difficulty putting such skills to use precisely when they need them--in social situations. In four studies, we examined whether lonely people choke under social pressure by asking participants to complete social sensitivity tasks framed as diagnostic of social skills or nonsocial skills. Across studies, lonely participants performed worse than nonlonely participants on social sensitivity tasks framed as tests of social aptitude, but they performed just as well or better than the nonlonely when the same tasks were framed as tests of academic aptitude. Mediational analyses in Study 3 and misattribution effects in Study 4 indicate that anxiety plays an important role in this choking effect. This research suggests that lonely individuals may not need to acquire social skills to escape loneliness; instead, they must learn to cope with performance anxiety in interpersonal interactions. © 2015 by the Society for Personality and Social Psychology, Inc.

  6. Outpatient blood pressure monitoring using bi-directional text messaging.

    Science.gov (United States)

    Anthony, Chris A; Polgreen, Linnea A; Chounramany, James; Foster, Eric D; Goerdt, Christopher J; Miller, Michelle L; Suneja, Manish; Segre, Alberto M; Carter, Barry L; Polgreen, Philip M

    2015-05-01

    To diagnose hypertension, multiple blood pressure (BP) measurements are recommended. We randomized patients into three groups: EMR-only (patients recorded BP measurements in an electronic medical record [EMR] web portal), EMR + reminders (patients were sent text message reminders to record their BP measurements in the EMR), and bi-directional text messaging (patients were sent a text message asking them to respond with their current BP). Subjects were asked to complete 14 measurements. Automated messages were sent to each patient in the bi-directional text messaging and EMR + reminder groups twice daily. Among 121 patients, those in the bi-directional text messaging group reported the full 14 measurements more often than both the EMR-only group (P text messaging is an effective way to gather patient BP data. Text-message-based reminders alone are an effective way to encourage patients to record BP measurements. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Tractor perfomance as a function of speed and seeder’s tire inflation pressure Desempenho de trator em função da velocidade e da pressão de inflação dos pneus da semeadora

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Angeli Furlani

    2010-08-01

    Full Text Available The performance of agricultural tractors under field conditions results from the interaction between tire and wheel affected by displacement speed. This work was developed to assess the performance of an agricultural tractor under different seeder's tire inflation pressure (518; 483 and 414kPa and in two different gears providing speeds of 3.0 and 6.0km h-1. The experiment was performed at Jaboticabal Campus of São Paulo State University (UNESP. The experimental design used was entirely randomized in a 2-factor factorial design (3x2 with four replications. The draft force was influenced by the gear as well as by the required power; however, tire inflation pressure in the seeder did not change these parameters. Also, fuel consumption was influenced only by the tractor gear. Energy consumption was greater as speed increased, caused by gear shifting. The displacement speed was greater for the 518kPa pressure due to a lesser slippage in the seeder under this pressure. Tractor slippage did not change.O desempenho de tratores agrícolas em condições de campo resulta da interação entre pneu e rodado, influenciado pela velocidade de deslocamento. O objetivo deste trabalho foi avaliar o desempenho de um trator agrícola sob diferentes pressões de inflação dos pneus da semeadora (518, 483, and 414kPa e em duas marchas que proporcionaram velocidades de 3,0 e 6,0km h-1. O experimento foi realizado no campus de Jaboticabal da Universidade Estadual Paulista (UNESP. O delineamento experimental utilizado foi fatorial inteiramente casualizado (3x2, com quatro repetições. A força de tração foi influenciada pela marcha e pela potência exigida; no entanto, a pressão de inflação do pneu da semeadora não alterou esses parâmetros. Além disso, o consumo de combustível foi influenciado apenas pela marcha do trator. O consumo de energia foi maior com o aumento da velocidade, ocasionada pela mudança de marcha. A velocidade de deslocamento foi maior

  8. Vehicle Tire and Wheel Creation in BRL-CAD

    Science.gov (United States)

    2009-04-01

    Tire Tread Modeling 4  4.  Setting Tire Thickness 7  5.  Changing the Rim Width 9  6.  Changing the Radial Location of the... treaded or nontreaded model in the tire -model.c combination based on the analysis. 4. Setting Tire Thickness Tire thickness is manipulated via... tread is not modeled by default but can be added using options. • Fine-grained control of parameters such as tire thickness is available with

  9. Tire Models for Use in Braking Applications

    OpenAIRE

    Svendenius, Jacob

    2003-01-01

    The tire is a significant part for control of a vehicle. For a well-working brake system the contact properties between the tire and the ground is the limiting factor for a safe braking. To get optimal performance it is important that the system can utilize all friction resources. The brush tire model was a popular method in the 1960's and 1970's before the empirical approaches became dominating. The brush model gives an educational interpretation of the physics behind the tire behavi...

  10. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care.

    Science.gov (United States)

    Chen, Lisa Y; Tee, Benjamin C-K; Chortos, Alex L; Schwartz, Gregor; Tse, Victor; Lipomi, Darren J; Wong, H-S Philip; McConnell, Michael V; Bao, Zhenan

    2014-10-06

    Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.

  11. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    Science.gov (United States)

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  12. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures.

    Science.gov (United States)

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-08-01

    Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Automated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.

    Science.gov (United States)

    Zhang, Ling; Baldwin, Ian; Zhu, Guijun; Tanaka, Aiko; Bellomo, Rinaldo

    2015-03-01

    Automated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function. Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis. We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout. Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.

  14. Electrostatic discharges and their effect on the validity of registered values in intracranial pressure monitors

    DEFF Research Database (Denmark)

    Andresen, Morten; Thomsen, Ole Cornelius; Juhler, Marianne

    2013-01-01

    Object Intracranial pressure (ICP) monitoring is used extensively in clinical practice, and as such, the accuracy of registered ICP values is paramount. Clinical observations of nonphysiological changes in ICP have called into question the accuracy of registered ICP values. Subsequently, the auth......Object Intracranial pressure (ICP) monitoring is used extensively in clinical practice, and as such, the accuracy of registered ICP values is paramount. Clinical observations of nonphysiological changes in ICP have called into question the accuracy of registered ICP values. Subsequently......, the authors have tried to determine if the ICP monitors from major manufacturers were affected by electrostatic discharges (ESDs), if the changes were permanent or transient in nature, and if the changes were modified by the addition of different electrical appliances normally used in the neurointensive care....... Results Five pressure monitors from 4 manufacturers were evaluated. Three monitors containing electrical circuitry at the tip of the transducer were all affected by ESDs. Clinically significant permanent changes in the reported ICP values for 1 pressure monitor were observed, as well as temporary...

  15. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  16. Current Research in Aircraft Tire Design and Performance

    Science.gov (United States)

    Tanner, J. A.; Mccarthy, J. L.; Clark, S. K.

    1981-01-01

    A review of the tire research programs which address the various needs identified by landing gear designers and airplane users is presented. The experimental programs are designed to increase tire tread lifetimes, relate static and dynamic tire properties, establish the tire hydroplaning spin up speed, study gear response to tire failures, and define tire temperature profiles during taxi, braking, and cornering operations. The analytical programs are aimed at providing insights into the mechanisms of heat generation in rolling tires and developing the tools necessary to streamline the tire design process and to aid in the analysis of landing gear problems.

  17. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial.

    Science.gov (United States)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter; Gregers Petersen, Hans; Benee Olsen, David; Berg, Ronan M G; Abrahamsen, Henrik; Wiinberg, Niels

    2018-01-17

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark. One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent home blood pressure monitoring and 24-hour ambulatory blood pressure monitoring. Mean day- and night-time systolic and diastolic 24-hour ambulatory blood pressure. Change in systolic and diastolic office blood pressure and change in cardiovascular risk profile. Of the patients, 515 (49%) were allocated to the usual group, and 533 (51%) to the intensive group. The reductions in day- and night-time 24-hour ambulatory blood pressure were similar (usual group: 4.6 ± 13.5/2.8 ± 82 mmHg; intensive group: 5.6 ± 13.0/3.5 ± 8.2 mmHg; P = 0.27/P = 0.20). Cardiovascular risk scores were reduced in both groups at follow-up, but more so in the intensive than in the usual group (P = 0.02). An intensive blood pressure monitoring strategy led to a similar blood pressure reduction to conventional monitoring. However, the intensive strategy appeared to improve patients' cardiovascular risk profile through other effects than a reduction of blood pressure. Clinical Trials NCT00244660. © The Author 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Determining soil hydrologic characteristics on a remote forest watershed by continuous monitoring of soil water pressures, rainfall and runoff.

    Science.gov (United States)

    L.R. Ahuja; S. A. El-Swaify

    1979-01-01

    Continuous monitoring of soil-water pressures, rainfall and runoff under natural conditions was tested as a technique for determining soil hydrologic characteristics of a remote forest watershed plot. A completely battery-powered (and thus portable) pressure transducer–scanner–recorder system was assembled for monitoring of soil-water pressures in...

  19. The Utility of Ambulatory Blood Pressure Monitoring for Diagnosing White Coat Hypertension in Older Adults.

    Science.gov (United States)

    Reynolds, Kristi; Bowling, C Barrett; Sim, John J; Sridharan, Lakshmi; Harrison, Teresa N; Shimbo, Daichi

    2015-11-01

    The beneficial effect of antihypertensive medication on reducing the risk of cardiovascular disease (CVD) events is supported by data from randomized controlled trials of older adults with hypertension. However, in clinical practice, overtreatment of hypertension in older adults may lead to side effects and an increased risk of falls. The diagnosis and treatment of hypertension is primarily based on blood pressure measurements obtained in the clinic setting. Ambulatory blood pressure monitoring (ABPM) complements clinic blood pressure by measuring blood pressure in the out-of-clinic setting. ABPM can be used to identify white coat hypertension, defined as elevated clinic blood pressure and non-elevated ambulatory blood pressure. White coat hypertension is common in older adults but does not appear to be associated with an increased risk of CVD events among this population. Herein, we review the current literature on ABPM in the diagnoses of white coat hypertension in older adults, including its potential role in preventing overtreatment.

  20. The Utility of Ambulatory Blood Pressure Monitoring for Diagnosing White Coat Hypertension in Older Adults

    Science.gov (United States)

    Reynolds, Kristi; Bowling, C. Barrett; Sim, John J.; Sridharan, Lakshmi; Harrison, Teresa N.; Shimbo, Daichi

    2015-01-01

    The beneficial effect of antihypertensive medication on reducing the risk of cardiovascular disease (CVD) events is supported by data from randomized controlled trials of older adults with hypertension. However, in clinical practice, overtreatment of hypertension in older adults may lead to side effects and an increased risk of falls. The diagnosis and treatment of hypertension is primarily based on blood pressure measurements obtained in the clinic setting. Ambulatory blood pressure monitoring (ABPM) complements clinic blood pressure by measuring blood pressure in the out-of-clinic setting. ABPM can be used to identify white coat hypertension, defined as elevated clinic blood pressure and non-elevated ambulatory blood pressure. White coat hypertension is common in older adults but does not appear to be associated with an increased risk of CVD events among this population. Herein, we review the current literature on ABPM in the diagnoses of white coat hypertension in older adults, including its potential role in preventing overtreatment. PMID:26400076

  1. A Wireless and Real-Time Monitoring System Design for Car Networking Applications

    Directory of Open Access Journals (Sweden)

    Li Wenjun

    2013-01-01

    Full Text Available We described a wireless and monitoring system to obtain several classes of vehicle data and send them to the server via General Packet Radio Service (GPRS in real-time. These data are consisted by on-board diagnostic (OBD which get from the vehicle’s OBD interface, Tire-Pressure Monitoring system (TPMS and Global Positioning System (GPS. The main content of this paper is the hardware design of the system, especially RF modules and antennas.

  2. Type GQS-1 high pressure steam manifold water level monitoring system

    International Nuclear Information System (INIS)

    Li Nianzu; Li Beicheng; Jia Shengming

    1993-10-01

    The GQS-1 high pressure steam manifold water level monitoring system is an advanced nuclear gauge that is suitable for on-line detecting and monitor in high pressure steam manifold water level. The physical variable of water level is transformed into electrical pulses by the nuclear sensor. A computer is equipped for data acquisition, analysis and processing and the results are displayed on a 14 inch color monitor. In addition, a 4 ∼ 20 mA output current is used for the recording and regulation of water level. The main application of this gauge is for on-line measurement of high pressure steam manifold water level in fossil-fired power plant and other industries

  3. Post-consumer tires back into new tires: de-vulcanization and re-utilization of passenger car tires

    NARCIS (Netherlands)

    Saiwari, Sitisaiyidah

    2013-01-01

    Enabling recycling loops for used passenger car tires is a challenge and an opportunity. The challenge lies in the presence of SBR as the main elastomer in this type of tires, which makes this material difficult to reclaim due to the tendency of the elastomer chain fragments to re-combine. The

  4. Semeadora-adubadora: exigências em função do preparo do solo, da pressão de inflação do pneu e da velocidade Planter: requirements as related to soil tillage, tire pressure, and machine speed

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Angeli Furlani

    2008-02-01

    Full Text Available As semeadoras-adubadoras, responsáveis pela correta adição de semente e adubo ao solo, possuem mecanismos dosadores acionados por suas rodas motrizes, que giram em função do contato com a superfície do solo. Esse contato é influenciado, entre outros fatores, pela pressão de inflação dos pneus. O objetivo do presente trabalho foi estudar o desempenho de uma semeadora-adubadora de precisão em função do preparo do solo (preparo convencional e plantio direto, das velocidades de deslocamento e da pressão de inflação do seu pneu. O trabalho foi realizado na UNESP de Jaboticabal (SP no ano de 2006. Foram avaliadas as seguintes variáveis: força de tração e potência na barra, consumo de combustível (horário, ponderal, operacional e específico, capacidade de campo operacional, patinagem dos rodados do trator e da semeadora-adubadora, estande inicial e distribuição longitudinal de sementes. O sistema plantio direto demandou maior força (35 %, potência e consumo horário de combustível; o mesmo aconteceu na maior velocidade. A pressão de inflação das rodas da semeadora proporcionou menor patinagem e maior estande inicial de plântulas.Planter machines, responsible for the correct placing of seeds and fertilizer in the ground, have dosing mechanisms set in motion by the drive wheels, as they rotate in function of the contact with the ground surface. This contact is influenced, among other factors, by tire pressure. The objective of this work was to study the performance of a planter as affected by soil tillage, machine speed and planter tire pressure. The following variables were evaluated: traction force and drawbar pull, fuel consumption, field capacity, wheel skidding, initial stand and longitudinal seed distribution. The greatest force was needed in the no-tillage system, which also demanded the highest power and hourly fuel consumption. The same results were found at the fastest speed. In this system the tire pressure of

  5. Intraocular pressure monitoring by rebound tonometry in children with myopia.

    Science.gov (United States)

    Weng, Jenchieh; Tsai, I-Lun; Kuo, Li-Lin; Tsai, Ching-Yao; Woung, Lin-Chung; Hsiao, Ya-Chuan

    2017-01-01

    Topical atropine treatment is generally accepted to retard the progression of myopia, but it is associated with side effects such as photophobia and elevation of intraocular pressure (IOP). IOP measurements in children are challenging. The traditional applanation tonometry by direct contact with the cornea will require patient's cooperation. The rebound tonometer, using a dynamic electromechanical method for measuring IOP, shows good correlation with traditional tonometry. The purpose of this study is to evaluate the IOP of myopic children under atropine treatment using rebound tonometer and to compare the characteristics between rebound tonometry and applanation tonometry. This study is a prospective study measuring IOP by rebound tonometer in myopic children under regular low-dose atropine treatment. We recruited children with refraction error showing myopia over -0.5 D with 0.15%, 0.3%, or 0.5% atropine eye drops use every night or every other night for myopia control. Children with treatment duration of atropine tonometer (Tono-Pen XL, Reichert) and rebound tonometer (ICARE). The reliability of rebound tonometer was analyzed with percentage. Comparison of IOP between rebound tonometer and applanation tonometry was presented. The rebound tonometry was well tolerated by all participants and caused no complaints, discomfort, or adverse events. Totally 42 myopic eyes of 42 subjects were included in the study. The average age of these participants was 10 years old, range from 5 to 16. Median = 10 years old. The average IOP of the right eye by rebound tonometer was 17.4 ± 3 mmHg, and 17.1 ± 3 mmHg by applanation tonometry. Nearly 19%, 33%, and 24% of difference of IOP readings between rebound tonometer and Tono-Pen applanation are within 0 mmHg, 1 mmHg, and 1-2 mmHg, respectively. Rebound tonometry has good correlation with applanation tonometry and 76.1% of differences between two tonometers are <2 mmHg. The advantage of drop-free rebound tonometry has made it

  6. Risk Stratification by Ambulatory Blood Pressure Monitoring Across JNC Classes of Conventional Blood Pressure

    DEFF Research Database (Denmark)

    Brguljan-Hitij, Jana; Thijs, Lutgarde; Li, Yan

    2014-01-01

    BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (<120/<80 mm Hg), prehypertension (120-139/80-89 mm Hg), and hypertension (≥140/≥90 mm Hg). METHODS: To assess the potential differential contribution of ambulatory blood pressure (ABP) in predict......BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (ABP......%) and of cardiovascular (-34%), cardiac (-33%), or cerebrovascular (-47%) events. Multivariable-adjusted hazard ratios (HRs) for stroke associated with 24-hour and daytime diastolic ABP (+5 mm Hg) were higher (P ≤ 0.045) in normotension than in prehypertension and hypertension (1.98 vs.1.19 vs.1.28 and 1.73 vs.1.09 vs. 1.......24, respectively) with similar trends (0.03 ≤ P ≤ 0.11) for systolic ABP (+10 mm Hg). However, HRs for fatal endpoints and cardiac events associated with ABP did not differ significantly (P ≥ 0.13) across CBP categories. Of normotensive and prehypertensive participants, 7.5% and 29.3% had masked hypertension...

  7. Sensor response monitoring in pressurized water reactors using time series modeling

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Kerlin, T.W.

    1978-01-01

    Random data analysis in nuclear power reactors for purposes of process surveillance, pattern recognition and monitoring of temperature, pressure, flow and neutron sensors has gained increasing attention in view of their potential for helping to ensure safe plant operation. In this study, application of autoregressive moving-average (ARMA) time series modeling for monitoring temperature sensor response characteristrics is presented. The ARMA model is used to estimate the step and ramp response of the sensors and the related time constant and ramp delay time. The ARMA parameters are estimated by a two-stage algorithm in the spectral domain. Results of sensor testing for an operating pressurized water reactor are presented. 16 refs

  8. The clinical utility of ambulatory blood pressure monitoring (ABPM): a review.

    Science.gov (United States)

    Harianto, Harry; Valente, Michael; Hoetomo, Soenarno; Anpalahan, Mahesan

    2014-01-01

    The current evidence suggests that ambulatory blood pressure monitoring (ABPM) should be an integral part of the diagnosis and management of hypertension. However, its uptake in routine clinical practice has been variable. This paper reviews the current evidence for the role of ABPM in clinical practice, including in hypotensive disorders and in specific comorbidities. It further discusses the clinical significance of abnormal ambulatory blood pressure patterns and hypertensive syndromes such as white coat, masked and resistant hypertension.

  9. Non-Invasive Ultrasonic Diagnosing and Monitoring of Intracranial Pressure/Volume

    Science.gov (United States)

    2001-10-01

    Libraria, Padoue (Italia) 53 37. Guinduiz G, Viernstein LW (1979). Intracranial pressure in the normal monkey while awake and asleep. J Neurosurg 51, 206...cerebral microcirculation of awake rabbits. Heart Circ Physiol 23, H67-H71 46. Hyndman BW, Kitney RI, Sayers BM (1971). Spontaneous rhythms in...intracranial pressure monitoring. Exclusion criteria: patients with wounds, scars or a craniotomy overlying the optimal window for transintracranial

  10. Infinite-Dimensional Observer for Process Monitoring in Managed Pressure Drilling

    OpenAIRE

    Hasan, Agus Ismail

    2015-01-01

    Utilizing flow rate and pressure data in and out of the mud circulation loop provides a driller with real-time trends for the early detection of well-control problems that impact the drilling efficiency. This paper presents state estimation for infinite-dimensional systems used in the process monitoring of oil well drilling. The objective is to monitor the key process variables associated with process safety by designing a model-based nonlinear observer that directly utilizes the available in...

  11. Validation of New Crack Monitoring Technique for Victoria Class High-Pressure Air Bottles

    Science.gov (United States)

    2014-06-01

    Defence Research and Development Canada Recherche et développement pour la défense Canada Validation of new crack monitoring technique for Victoria ...Validation of new crack monitoring technique for Victoria class high-pressure air bottles Ian Thompson John R. MacKay Defence Research and Development...Canada Scientific Report DRDC-RDDC-2014-R81 June 2014 © Her Majesty the Queen in Right of Canada (Department of National Defence), 2014 © Sa Majesté

  12. Patients’ blood pressure knowledge, perceptions and monitoring practices in community pharmacies

    OpenAIRE

    Lam, Jennifer Y.; Guirguis, Lisa M.

    2010-01-01

    Hypertension is a modifiable risk factor for cardiovascular disease. Despite this, patients often cannot or inaccurately estimate their risk factors.Objectives: In order to improve pharmacist interventions, we sought to: 1) find out patients’ knowledge about blood pressure (BP) and their self- monitoring behaviors and 2) identify the relationships between these two elements. Specifically, if evaluation of BP control were related to knowledge of one’s BP level and self-monitoring habits, and i...

  13. Ambulatory Blood Pressure Monitoring: Five Decades of More Light and Less Shadows

    Science.gov (United States)

    Nobre, Fernando; Mion Junior, Décio

    2016-01-01

    Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review. PMID:27168473

  14. Development of a high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors.

    Science.gov (United States)

    Suresh, R; Bhalla, S; Hao, J; Singh, C

    2015-01-01

    High importance is given to plantar pressure monitoring in the field of biomedical engineering for the diagnosis of posture related ailments associated with diseases such as diabetes and gonarthrosis. This paper presents the proof-of-concept development of a new high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors. In the proposed configuration, the FBG sensors are embedded within layers of carbon composite material (CCM) in turn conforming to an arc shape. A total of four such arc shaped sensors are instrumented in the pad at the locations of the forefoot and the hind foot. As a test of the pad, static plantar pressure is monitored on normal subjects under various posture conditions. The pad is evaluated both as a standalone platform as well as a pad inserted inside a standard shoe. An average pressure sensitivity of 1.2 pm/kPa and a resolution of approximately 0.8 kPa is obtained in this special configuration. The pad is found to be suitable in both configurations- stand-alone pad as well as an insert inside a standard shoe. The proposed set up offers a cost-effective high resolution and accurate plantar pressure measurement system suitable for clinical deployment. The novelty of the developed pressure pad lies in its ability to be used both as platform type as well as inserted in-sole type sensor system.

  15. Tire recycling technologies: What is the future?

    NARCIS (Netherlands)

    Saiwari, Sitisaiyidah; van Hoek, Johannes Wilhelmus; Dierkes, Wilma K.; Noordermeer, Jacobus W.M.; Blume, Anke; Heideman, G.

    2016-01-01

    Recycling is a heavily discussed topic nowadays, and recycled tire material to be re-used for the same application is one of the spear points of current R&D activities. Regarding the immense amount of used tires, more than just one outlet for the recycled material is needed. Besides the commonly

  16. Tire containing thermally exfoliated graphite oxide

    Science.gov (United States)

    Prud'homme, Robert K. (Inventor); Aksay, Ilhan A. (Inventor)

    2011-01-01

    A tire, tire lining or inner tube, containing a polymer composite, made of at least one rubber and/or at least one elastomer and a modified graphite oxide material, which is a thermally exfoliated graphite oxide with a surface area of from about 300 sq m/g to 2600 sq m/g.

  17. Intraspinal Pressure Monitoring in a Patient with Spinal Cord Injury Reveals Different Intradural Compartments: Injured Spinal Cord Pressure Evaluation (ISCoPE) Study.

    OpenAIRE

    Phang, I; Papadopoulos, MC

    2015-01-01

    BACKGROUND: We recently described a technique for monitoring intraspinal pressure (ISP) after traumatic spinal cord injury (TSCI). This is analogous to intracranial pressure monitoring after brain injury. We showed that, after severe TSCI, ISP at the injury site is elevated as the swollen cord is compressed against the dura. METHODS: In a patient with complete thoracic TSCI, we sequentially monitored subdural ISP above the injury, at the injury site, and below the injury intraoperatively. Pos...

  18. Using acoustic emission technique to monitor fractures on the analogous pressure pipes

    International Nuclear Information System (INIS)

    Zhang Lichen

    1989-01-01

    By using the acoustic emission technique to monitor the fractures on analogous pressure pipes of the primary circuit which has had cracks and loading with pressure was investigated. The dynamical process, from cracking to fracturing, was recorded by the acoustic emission technique. Comparing with the conventional method, this method gives more informations, such as pre-cracking, cracking growing, fast fracturing and the pressure values at different phases. During testing time a microcomputer was used for real-time data processing and locating the fracturing position. These data are useful for the mechanical analysis of the reactor components

  19. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    Science.gov (United States)

    Groen, Maarten S.; Wu, Kai; Brookhuis, Robert A.; van Houwelingen, Marc J.; Brouwer, Dannis M.; Lötters, Joost C.; Wiegerink, Remco J.

    2014-12-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch.

  20. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    International Nuclear Information System (INIS)

    Groen, Maarten S; Wu, Kai; Brookhuis, Robert A; Lötters, Joost C; Wiegerink, Remco J; Van Houwelingen, Marc J; Brouwer, Dannis M

    2014-01-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch. (paper)

  1. Method and apparatus for monitoring oxygen partial pressure in air masks

    Science.gov (United States)

    Kelly, Mark E. (Inventor); Pettit, Donald R. (Inventor)

    2006-01-01

    Method and apparatus are disclosed for monitoring an oxygen partial pressure in an air mask and providing a tactile warning to the user. The oxygen partial pressure in the air mask is detected using an electrochemical sensor, the output signal from which is provided to a comparator. The comparator compares the output signal with a preset reference value or range of values representing acceptable oxygen partial pressures. If the output signal is different than the reference value or outside the range of values, the air mask is vibrated by a vibrating motor to alert the user to a potentially hypoxic condition.

  2. Dynamics and Stability of Rolling Viscoelastic Tires

    Energy Technology Data Exchange (ETDEWEB)

    Potter, Trevor [Univ. of California, Berkeley, CA (United States)

    2013-04-30

    Current steady state rolling tire calculations often do not include treads because treads destroy the rotational symmetry of the tire. We describe two methodologies to compute time periodic solutions of a two-dimensional viscoelastic tire with treads: solving a minimization problem and solving a system of equations. We also expand on work by Oden and Lin on free spinning rolling elastic tires in which they disovered a hierachy of N-peak steady state standing wave solutions. In addition to discovering a two-dimensional hierarchy of standing wave solutions that includes their N-peak hiearchy, we consider the eects of viscoelasticity on the standing wave solutions. Finally, a commonplace model of viscoelasticity used in our numerical experiments led to non-physical elastic energy growth for large tire speeds. We show that a viscoelastic model of Govindjee and Reese remedies the problem.

  3. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  4. Utility of the theory of planned behavior to predict nursing staff blood pressure monitoring behaviours.

    Science.gov (United States)

    Nelson, Joan M; Cook, Paul F; Ingram, Jennifer C

    2014-02-01

    To evaluate constructs from the theory of planned behavior (TPB, Ajzen 2002) - attitudes, sense of control, subjective norms and intentions - as predictors of accuracy in blood pressure monitoring. Despite numerous initiatives aimed at teaching blood pressure measurement techniques, many healthcare providers measure blood pressures incorrectly. Descriptive, cohort design. Medical assistants and licensed practical nurses were asked to complete a questionnaire on TPB variables. These nursing staff's patients had their blood pressures measured and completed a survey about techniques used to measure their blood pressure. We correlated nursing staff's responses on the TBP questionnaire with their intention to measure an accurate blood pressure and with the difference between their actual blood pressure measurement and a second measurement taken by a researcher immediately after the clinic visit. Patients' perceptions of MAs' and LPNs' blood pressure measurement techniques were examined descriptively. Perceived control and social norm predicted intention to measure an accurate blood pressure, with a negative relationship between knowledge and intention. Consistent with the TPB, intention was the only significant predictor of blood pressure measurement accuracy. Theory of planned behavior constructs predicted the healthcare providers' intention to measure blood pressure accurately and intention predicted the actual accuracy of systolic blood pressure measurement. However, participants' knowledge about blood pressure measurement had an unexpected negative relationship with their intentions. These findings have important implications for nursing education departments and organisations which traditionally invest significant time and effort in annual competency training focused on knowledge enhancement by staff. This study suggests that a better strategy might involve efforts to enhance providers' intention to change, particularly by changing social norms or increasing

  5. Patients' blood pressure knowledge, perceptions and monitoring practices in community pharmacies.

    Science.gov (United States)

    Lam, Jennifer Y; Guirguis, Lisa M

    2010-07-01

    Hypertension is a modifiable risk factor for cardiovascular disease. Despite this, patients often cannot or inaccurately estimate their risk factors. IN ORDER TO IMPROVE PHARMACIST INTERVENTIONS, WE SOUGHT TO: 1) find out patients' knowledge about blood pressure (BP) and their self-monitoring behaviors and 2) identify the relationships between these two elements. Specifically, if evaluation of BP control were related to knowledge of one's BP level and self-monitoring habits, and if knowledge of one's target and BP level varied with monitoring habits. Final year pharmacy students were trained and interviewed patients in community pharmacies as a required exercise in their pharmacy clerkship. Each student recruited a convenience sample of 5-10 patients who were on hypertension medication, and surveyed them regarding their BP targets, recent BP levels as well as monthly and home BP monitoring practices. One third of the 449 patients interviewed were able to report a blood pressure target with 26% reporting a JNC 7 recognized target. Three quarters of patients who reported a blood pressure target were able to report a blood pressure level, with 12% being at their self-reported target. Roughly two thirds of patients perceived their BP to be "about right", and slightly less than a third thought it to be "high". Sixty percent of patients monitor their BP monthly, but less than 50% of patients practice home BP monitoring. This study along with others before it point to the knowledge and self-management gaps in patients with chronic conditions. Furthermore, pharmacy students were able to use a brief intervention to screen patients during routine care. Pharmacists can help improve patient understanding and promote increased self-management through regular BP monitoring.

  6. Patients’ blood pressure knowledge, perceptions and monitoring practices in community pharmacies

    Directory of Open Access Journals (Sweden)

    Lam JY

    2010-09-01

    Full Text Available Hypertension is a modifiable risk factor for cardiovascular disease. Despite this, patients often cannot or inaccurately estimate their risk factors.Objectives: In order to improve pharmacist interventions, we sought to: 1 find out patients’ knowledge about blood pressure (BP and their self- monitoring behaviors and 2 identify the relationships between these two elements. Specifically, if evaluation of BP control were related to knowledge of one’s BP level and self-monitoring habits, and if knowledge of one’s target and BP level varied with monitoring habits. Methods: Final year pharmacy students were trained and interviewed patients in community pharmacies as a required exercise in their pharmacy clerkship. Each student recruited a convenience sample of 5-10 patients who were on hypertension medication, and surveyed them regarding their BP targets, recent BP levels as well as monthly and home BP monitoring practices. Results: One third of the 449 patients interviewed were able to report a blood pressure target with 26% reporting a JNC 7 recognized target. Three quarters of patients who reported a blood pressure target were able to report a blood pressure level, with 12% being at their self- reported target. Roughly two thirds of patients perceived their BP to be “about right”, and slightly less than a third thought it to be “high”. Sixty percent of patients monitor their BP monthly, but less than 50% of patients practice home BP monitoring. Conclusions: This study along with others before it point to the knowledge and self-management gaps in patients with chronic conditions. Furthermore, pharmacy students were able to use a brief intervention to screen patients during routine care. Pharmacists can help improve patient understanding and promote increased self-management through regular BP monitoring.

  7. Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

    Science.gov (United States)

    Proença, Martin; Braun, Fabian; Solà, Josep; Thiran, Jean-Philippe; Lemay, Mathieu

    2017-06-01

    Current monitoring modalities for patients with pulmonary hypertension (PH) are limited to invasive solutions. A novel approach for the noninvasive and unsupervised monitoring of pulmonary artery pressure (PAP) in patients with PH was proposed and investigated. The approach was based on the use of electrical impedance tomography (EIT), a noninvasive and safe monitoring technique, and was tested through simulations on a realistic 4D bio-impedance model of the human thorax. Changes in PAP were induced in the model by simulating multiple types of hypertensive conditions. A timing parameter physiologically linked to the PAP via the so-called pulse wave velocity principle was automatically estimated from the EIT data. It was found that changes in PAP could indeed be reliably monitored by EIT, irrespective of the pathophysiological condition that caused them. If confirmed clinically, these findings could open the way for a new generation of noninvasive PAP monitoring solutions for the follow-up of patients with PH.

  8. Assessment of ambulatory blood pressure monitoring: better reproducibility with polynomial analysis

    NARCIS (Netherlands)

    Cleophas, A. F.; Zwinderman, A. H.; Cleophas, T. J.

    2000-01-01

    Objective: Ambulatory blood pressure monitoring (ABPM) data using values of arbitrarily separated day- and nighttime hours are poorly reproducible, undermining the validity of this diagnostic tool. Previous studies from our group have demonstrated that polynomial curves can be produced of ABPM data

  9. European society of hypertension position paper on ambulatory blood pressure monitoring

    NARCIS (Netherlands)

    O'Brien, Eoin; Parati, Gianfranco; Stergiou, George; Asmar, Roland; Beilin, Laurie; Bilo, Grzegorz; Clement, Denis; de la Sierra, Alejandro; de Leeuw, Peter; Dolan, Eamon; Fagard, Robert; Graves, John; Head, Geoffrey A.; Imai, Yutaka; Kario, Kazuomi; Lurbe, Empar; Mallion, Jean-Michel; Mancia, Giuseppe; Mengden, Thomas; Myers, Martin; Ogedegbe, Gbenga; Ohkubo, Takayoshi; Omboni, Stefano; Palatini, Paolo; Redon, Josep; Ruilope, Luis M.; Shennan, Andrew; Staessen, Jan A.; vanMontfrans, Gert; Verdecchia, Paolo; Waeber, Bernard; Wang, Jiguang; Zanchetti, Alberto; Zhang, Yuqing

    2013-01-01

    Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a

  10. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits.

    Science.gov (United States)

    Bellini, Luca; Veladiano, Irene A; Schrank, Magdalena; Candaten, Matteo; Mollo, Antonio

    2018-02-27

    Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. Although mean invasive

  11. Usage of post-consumer tires as raw materials

    Directory of Open Access Journals (Sweden)

    O.A. Vovk

    2006-04-01

    Full Text Available  This article is devoted to the problem of post-consumer tires accumulation and recycling both in Europe and Ukraine. It describes general tires properties, their structure and composite elements which are valuable secondary resources. Also there are analyzed the most known methods of used tires treatment and final product of tires utilizations.

  12. 49 CFR 574.5 - Tire identification requirements.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Tire identification requirements. 574.5 Section... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) TIRE IDENTIFICATION AND RECORDKEEPING § 574.5 Tire identification requirements. Each tire manufacturer shall conspicuously label on one...

  13. 40 CFR 202.23 - Visual tire inspection.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Visual tire inspection. 202.23 Section... Visual tire inspection. No motor carrier subject to these regulations shall at any time operate any motor vehicle of a type to which this regulation is applicable on a tire or tires having a tread pattern which...

  14. Monitoring pressure profiles across an airfoil with a fiber Bragg grating sensor array

    Science.gov (United States)

    Papageorgiou, Anthony W.; Parkinson, Luke A.; Karas, Andrew R.; Hansen, Kristy L.; Arkwright, John W.

    2018-02-01

    Fluid flow over an airfoil section creates a pressure difference across the upper and lower surfaces, thus generating lift. Successful wing design is a combination of engineering design and experience in the field, with subtleties in design and manufacture having significant impact on the amount of lift produced. Current methods of airfoil optimization and validation typically involve computational fluid dynamics (CFD) and extensive wind tunnel testing with pressure sensors embedded into the airfoil to measure the pressure over the wing. Monitoring pressure along an airfoil in a wind tunnel is typically achieved using surface pressure taps that consist of hollow tubes running from the surface of the airfoil to individual pressure sensors external to the tunnel. These pressure taps are complex to configure and not ideal for in-flight testing. Fiber Bragg grating (FBG) pressure sensing arrays provide a highly viable option for both wind tunnel and inflight pressure measurement. We present a fiber optic sensor array that can detect positive and negative pressure suitable for validating CFD models of airfoil profile sections. The sensing array presented here consists of 6 independent sensing elements, each capable of a pressure resolution of less than 10 Pa over the range of 70 kPa to 120 kPa. The device has been tested with the sensor array attached to a 90mm chord length airfoil section subjected to low velocity flow. Results show that the arrays are capable of accurately detecting variations of the pressure profile along the airfoil as the angle of attack is varied from zero to the point at which stall occurs.

  15. Wearable and low-stress ambulatory blood pressure monitoring technology for hypertension diagnosis.

    Science.gov (United States)

    Altintas, Ersin; Takoh, Kimiyasu; Ohno, Yuji; Abe, Katsumi; Akagawa, Takeshi; Ariyama, Tetsuri; Kubo, Masahiro; Tsuda, Kenichiro; Tochikubo, Osamu

    2015-01-01

    We propose a highly wearable, upper-arm type, oscillometric-based blood pressure monitoring technology with low-stress. The low-stress is realized by new developments in the hardware and software design. In the hardware design, conventional armband; cuff, is almost halved in volume thanks to a flexible plastic core and a liquid bag which enhances the fitness and pressure uniformity over the arm. Reduced air bag volume enables smaller motor pump size and battery leading to a thinner, more compact and more wearable unified device. In the software design, a new prediction algorithm enabled to apply less stress (and less pain) on arm of the patient. Proof-of-concept experiments on volunteers show a high accuracy on both technologies. This paper mainly introduces hardware developments. The system is promising for less-painful and less-stressful 24-hour blood pressure monitoring in hypertension managements and related healthcare solutions.

  16. Equilibrium analysis of hydrogen production using the steam-plasma gasification process of the used car tires

    International Nuclear Information System (INIS)

    Kuznetsov, V A; Kumkova, I I; Lerner, A S; Popov, V E

    2012-01-01

    The paper deals with the treatment of used car tires. The method of used tires plasma gasification is proposed. The investigation of the syngas composition was carried out according to the temperature and plasma flow rate variation. The method of the steam catalytic conversion of CO, which is a part of the syngas, and CaO usage are suggested. The results of the calculation modeling at various temperatures, pressures, and steam flow rates are presented.

  17. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  18. Post-consumer tires back into new tires: de-vulcanization and re-utilization of passenger car tires

    OpenAIRE

    Saiwari, Sitisaiyidah

    2013-01-01

    Enabling recycling loops for used passenger car tires is a challenge and an opportunity. The challenge lies in the presence of SBR as the main elastomer in this type of tires, which makes this material difficult to reclaim due to the tendency of the elastomer chain fragments to re-combine. The opportunity lies in the wide availability of the material and in the fact that passenger car tires form a huge potential market for recycled rubber. The aim of this study is to develop a de-vulcanizatio...

  19. Demonstration of a Packaged Capacitive Pressure Sensor System Suitable for Jet Turbofan Engine Health Monitoring

    Science.gov (United States)

    Scardelletti, Maximilian C.; Jordan, Jennifer L.; Meredith, Roger D.; Harsh, Kevin; Pilant, Evan; Usrey, Michael W.; Beheim, Glenn M.; Hunter, Gary W.; Zorman, Christian A.

    2016-01-01

    In this paper, the development and characterization of a packaged pressure sensor system suitable for jet engine health monitoring is demonstrated. The sensing system operates from 97 to 117 MHz over a pressure range from 0 to 350 psi and a temperature range from 25 to 500 deg. The sensing system consists of a Clapp-type oscillator that is fabricated on an alumina substrate and is comprised of a Cree SiC MESFET, MIM capacitors, a wire-wound inductor, chip resistors and a SiCN capacitive pressure sensor. The pressure sensor is located in the LC tank circuit of the oscillator so that a change in pressure causes a change in capacitance, thus changing the resonant frequency of the sensing system. The chip resistors, wire-wound inductors and MIM capacitors have all been characterized at temperature and operational frequency, and perform with less than 5% variance in electrical performance. The measured capacitive pressure sensing system agrees very well with simulated results. The packaged pressure sensing system is specifically designed to measure the pressure on a jet turbofan engine. The packaged system can be installed by way of borescope plug adaptor fitted to a borescope port exposed to the gas path of a turbofan engine.

  20. Forestry Tire Tractive Performance: New, Worn, and with Chains

    Science.gov (United States)

    C.R. Vechinski; C.R. Johnson; R.L. Raper; T.P. McDonald

    1999-01-01

    The tractive perfomance of a new tire, a worn tire, and a worn tire with forestry tire chains was measured in four soil types. Two of the soil types simulated forest-floor conditions with one soil type having a sulfate cover of pine straw and the other having a surface cover of sod. The two remaining soil types were bare. The worn tire with and without chains had...

  1. Survivability Enhanced Run-Flat Variable Footprint Tires

    Science.gov (United States)

    2010-08-17

    with tire tread . By varying the thickness and geometry of the polyurethane soft layer, this unique tire -wheel assembly can generate a wide array of...carcass severely damaged/punctured, provide the same dynamic deflection as the normal pneumatic tire , and provide similar tread life. Could a tire be...be for an optimized shape. Fig 8 shows the actual process applied to a current tire . The carbon fiber was added by removing the tread , cutting

  2. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

    Science.gov (United States)

    Kollias, Anastasios; Destounis, Antonios; Kalogeropoulos, Petros; Kyriakoulis, Konstantinos G; Ntineri, Angeliki; Stergiou, George S

    2018-07-01

    This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats ( r =0.67; P ABP monitoring had 100%/85% sensitivity/specificity (area under the curve 0.91; P ABP monitor with AF detector has high sensitivity and moderate specificity for AF screening during routine ABP monitoring. Thus, in elderly hypertensives, a 24-hour ABP recording with at least 26% of the readings suggesting AF indicates a high probability for AF diagnosis and should be regarded as an indication for performing 24-hour Holter monitoring. © 2018 American Heart Association, Inc.

  3. Effect of Friction Model and Tire Maneuvering on Tire-Pavement Contact Stress

    Directory of Open Access Journals (Sweden)

    Haichao Zhou

    2015-01-01

    Full Text Available This paper aims to simulate the effects of different friction models on tire braking. A truck radial tire (295/80R22.5 was modeled and the model was validated with tire deflection. An exponential decay friction model that considers the effect of sliding velocity on friction coefficients was adopted for analyzing braking performance. The result shows that the exponential decay friction model used for evaluating braking ability meets design requirements of antilock braking system (ABS. The tire-pavement contact stress characteristics at various driving conditions (static, free rolling, braking, camber, and cornering were analyzed. It is found that the change of driving conditions has direct influence on tire-pavement contact stress distribution. The results provide the guidance for tire braking performance evaluation.

  4. [The implications of the automatic blood pressure monitoring (ABPM) in the type I diabetes].

    Science.gov (United States)

    Cobuz, C

    2009-01-01

    The connection between hypertension and diabetes emerges, in medical practice, from the current belief imposed by the European Society of Cardiology adding to the notion of total cardiovascular risk. An increse in the systolic blood pressure at night time is the first detectable manifestation of the regulation disorders of the blood pressure in type I diabetes. An early increase of the nocturnal blood pressure can play a key role in the detection of the evolution towards diabetic nephropathy. This modification can be a valuable potential marker for the diabetic nephropathy and could provide a reason for treating the high risk patients before the onset of microalbuminuria. The evaluation of the nefropathy risk in the early stages of type I diabetes using Ambulatory Blood Pressure Monitoring (ABPM) method offers the best premisses for preventing the progression of the disease towards microalbuminuria and hypertension.

  5. Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring.

    Science.gov (United States)

    Dagdeviren, Canan; Su, Yewang; Joe, Pauline; Yona, Raissa; Liu, Yuhao; Kim, Yun-Soung; Huang, YongAn; Damadoran, Anoop R; Xia, Jing; Martin, Lane W; Huang, Yonggang; Rogers, John A

    2014-08-05

    The ability to measure subtle changes in arterial pressure using devices mounted on the skin can be valuable for monitoring vital signs in emergency care, detecting the early onset of cardiovascular disease and continuously assessing health status. Conventional technologies are well suited for use in traditional clinical settings, but cannot be easily adapted for sustained use during daily activities. Here we introduce a conformal device that avoids these limitations. Ultrathin inorganic piezoelectric and semiconductor materials on elastomer substrates enable amplified, low hysteresis measurements of pressure on the skin, with high levels of sensitivity (~0.005 Pa) and fast response times (~0.1 ms). Experimental and theoretical studies reveal enhanced piezoelectric responses in lead zirconate titanate that follow from integration on soft supports as well as engineering behaviours of the associated devices. Calibrated measurements of pressure variations of blood flow in near-surface arteries demonstrate capabilities for measuring radial artery augmentation index and pulse pressure velocity.

  6. Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First- Morning Micturition and in the Afternoon

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Monteiro de Almeida

    2014-10-01

    Full Text Available Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM. Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM as gold-standard and measurements taken before morning micturition (BM and in the afternoon (AM, for the best diagnosis of systemic arterial hypertension (SAH, and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM; and with post-morning-micturition and evening measurements (PM+EM. All patients underwent echocardiography (for left ventricular hypertrophy - LVH and urinary albumin measurement (for microalbuminuria - MAU. Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM and (PM+EM, and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM versus (PM+EM were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM and (PM+EM were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

  7. Bayesian inference for heterogeneous caprock permeability based on above zone pressure monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Namhata, Argha; Small, Mitchell J.; Dilmore, Robert M.; Nakles, David V.; King, Seth

    2017-02-01

    The presence of faults/ fractures or highly permeable zones in the primary sealing caprock of a CO2 storage reservoir can result in leakage of CO2. Monitoring of leakage requires the capability to detect and resolve the onset, location, and volume of leakage in a systematic and timely manner. Pressure-based monitoring possesses such capabilities. This study demonstrates a basis for monitoring network design based on the characterization of CO2 leakage scenarios through an assessment of the integrity and permeability of the caprock inferred from above zone pressure measurements. Four representative heterogeneous fractured seal types are characterized to demonstrate seal permeability ranging from highly permeable to impermeable. Based on Bayesian classification theory, the probability of each fractured caprock scenario given above zone pressure measurements with measurement error is inferred. The sensitivity to injection rate and caprock thickness is also evaluated and the probability of proper classification is calculated. The time required to distinguish between above zone pressure outcomes and the associated leakage scenarios is also computed.

  8. NASA tire/runway friction projects

    Science.gov (United States)

    Yager, Thomas J.

    1995-01-01

    The paper reviews several aspects of NASA Langley Research Center's tire/runway friction evaluations directed towards improving the safety and economy of aircraft ground operations. The facilities and test equipment used in implementing different aircraft tire friction studies and other related aircraft ground performance investigations are described together with recent workshop activities at NASA Wallops Flight Facility. An overview of the pending Joint NASA/Transport Canada/FM Winter Runway Friction Program is given. Other NASA ongoing studies and on-site field tests are discussed including tire wear performance and new surface treatments. The paper concludes with a description of future research plans.

  9. The application of external vibration monitoring to reactors with concrete pressure vessels

    International Nuclear Information System (INIS)

    Hammill, W.J.

    1979-01-01

    The application of external vibration monitoring techniques to advanced gas cooled reactors (AGR) which have concrete pressure vessels is considered. A monitoring system for a particular AGR coolant circuit structure is developed, whose primary objective is to detect impacting of two components, although the detection of forced vibration response is also considered. Experimental results from instrumented components in the reactor and data from rig tests on full size units have been used together with a mathematical model of some elements of the transmission path in order to establish its dynamic characteristics and relate internal component vibration to externally measured signals. The application of external vibration monitoring to the external detection of the forced vibration response of an internal reactor assembly and the remote monitoring of circulator sound output is discussed. (author)

  10. Effect of Friction Model and Tire Maneuvering on Tire-Pavement Contact Stress

    OpenAIRE

    Haichao Zhou; Guolin Wang; Yangmin Ding; Jian Yang; Chen Liang; Jing Fu

    2015-01-01

    This paper aims to simulate the effects of different friction models on tire braking. A truck radial tire (295/80R22.5) was modeled and the model was validated with tire deflection. An exponential decay friction model that considers the effect of sliding velocity on friction coefficients was adopted for analyzing braking performance. The result shows that the exponential decay friction model used for evaluating braking ability meets design requirements of antilock braking system (ABS). The ti...

  11. Battery-Free Smart Sock for Abnormal Relative Plantar Pressure Monitoring.

    Science.gov (United States)

    Lin, Xiaoyou; Seet, Boon-Chong

    2017-04-01

    This paper presents a new design of a wearable plantar pressure monitoring system in the form of a smart sock for sensing abnormal relative pressure changes. One advantage of this approach is that with a battery-free design, this system can be powered solely by radio frequency (RF) energy harvested from a radio frequency identification (RFID) reader unit hosted on a smartphone of the wearer. At the same time, this RFID reader can read foot pressure values from an embedded sensor-tag in the sock. A pressure sensing matrix made of conductive fabric and flexible piezo-resistive material is integrated into the sock during the knitting process. Sensed foot pressures are digitized and stored in the memory of a sensor-tag, thus allowing relative foot pressure values to be tracked. The control unit of the smart sock is assembled on a flexible printed circuit board (FPC) that can be strapped to the lower limb and detached easily when it is not in use. Experiments show that the system can operate reliably in both tasks of RF energy harvesting and pressure measurement.

  12. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  13. Tire-road noise: an experimental study of tire and road design parameters

    OpenAIRE

    Bekke, Dirk; Wijnant, Ysbrand H.; Weegerink, Thijs; de Boer, Andries

    2013-01-01

    It is widely known that road traffic noise has negative influences on human health. Hence, as tire-road noise is considered to be the most dominant cause of road traffic noise above 30-50 km/h, a lot of research is performed by the two involving industries: road authorities/manufacturers and tire manufacturers. Usually, the parameters influencing exterior tire-road noise are often examined separately, whereas it is the tire-road interaction which obviously causes the actual noise. An integral...

  14. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  15. Validation of the BPUMP BF1112 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Chen, Qi; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2017-04-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor BPUMP BF1112 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010 (ESH-IP2010). Systolic and diastolic BPs were sequentially measured in 33 adult Chinese (13 women, mean age 46.7 years) using a mercury sphygmomanometer (two observers) and the BF1112 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The BPUMP BF1112 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 85/99, 96/99, and 97/99, respectively, for systolic BP, and 83/99, 97/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. A total of 31 and 30 participants for systolic and diastolic BP, respectively, had at least two of the three device-observer differences within 5 mmHg (required≥24mmHg). No participant for systolic or diastolic BP had all the three device-observer comparisons greater than 5 mmHg. The BPUMP BP monitor BF1112 has passed the requirements of the ESH-IP2010, and hence can be recommended for home use in adults.

  16. Demonstration of the waste tire pyrolysis process on pilot scale in a continuous auger reactor

    International Nuclear Information System (INIS)

    Martínez, Juan Daniel; Murillo, Ramón; García, Tomás; Veses, Alberto

    2013-01-01

    Highlights: • The continuous pyrolysis of waste tire has been demonstrated at pilot scale in an auger reactor. • More than 500 kg of waste tires were processed in 100 operational hours. • The yields and characteristics of the pyrolysis products remained constant. • Mass and energy balances for an industrial scale plant are provided. • The reaction enthalpy necessary to perform the waste tire pyrolysis was determined. -- Abstract: This work shows the technical feasibility for valorizing waste tires by pyrolysis using a pilot scale facility with a nominal capacity of 150 kW th . A continuous auger reactor was operated to perform thirteen independent experiments that conducted to the processing of more than 500 kg of shredded waste tires in 100 h of operation. The reaction temperature was 550 °C and the pressure was 1 bar in all the runs. Under these conditions, yields to solid, liquid and gas were 40.5 ± 0.3, 42.6 ± 0.1 and 16.9 ± 0.3 wt.% respectively. Ultimate and proximate analyses as well as heating value analysis were conducted for both the solid and liquid fraction. pH, water content, total acid number (TAN), viscosity and density were also assessed for the liquid and compared to the specifications of marine fuels (standard ISO 8217). Gas chromatography was used to calculate the composition of the gaseous fraction. It was observed that all these properties remained practically invariable along the experiments without any significant technical problem. In addition, the reaction enthalpy necessary to perform the waste tire pyrolysis process (907.1 ± 40.0 kJ/kg) was determined from the combustion and formation enthalpies of waste tire and conversion products. Finally, a mass balance closure was performed showing an excellent reliability of the data obtained from the experimental campaign

  17. Demonstration of the waste tire pyrolysis process on pilot scale in a continuous auger reactor

    Energy Technology Data Exchange (ETDEWEB)

    Martínez, Juan Daniel, E-mail: juand.martinez@upb.edu.co [Instituto de Carboquímica, ICB-CSIC, Miguel Luesma Castán 4, 50018, Zaragoza (Spain); Grupo de Investigaciones Ambientales, Instituto de Energía, Materiales y Medio Ambiente, Universidad Pontificia Bolivariana, Circular 1 N°70-01, Bloque 11, piso 2, Medellín (Colombia); Murillo, Ramón; García, Tomás; Veses, Alberto [Instituto de Carboquímica, ICB-CSIC, Miguel Luesma Castán 4, 50018, Zaragoza (Spain)

    2013-10-15

    Highlights: • The continuous pyrolysis of waste tire has been demonstrated at pilot scale in an auger reactor. • More than 500 kg of waste tires were processed in 100 operational hours. • The yields and characteristics of the pyrolysis products remained constant. • Mass and energy balances for an industrial scale plant are provided. • The reaction enthalpy necessary to perform the waste tire pyrolysis was determined. -- Abstract: This work shows the technical feasibility for valorizing waste tires by pyrolysis using a pilot scale facility with a nominal capacity of 150 kW{sub th}. A continuous auger reactor was operated to perform thirteen independent experiments that conducted to the processing of more than 500 kg of shredded waste tires in 100 h of operation. The reaction temperature was 550 °C and the pressure was 1 bar in all the runs. Under these conditions, yields to solid, liquid and gas were 40.5 ± 0.3, 42.6 ± 0.1 and 16.9 ± 0.3 wt.% respectively. Ultimate and proximate analyses as well as heating value analysis were conducted for both the solid and liquid fraction. pH, water content, total acid number (TAN), viscosity and density were also assessed for the liquid and compared to the specifications of marine fuels (standard ISO 8217). Gas chromatography was used to calculate the composition of the gaseous fraction. It was observed that all these properties remained practically invariable along the experiments without any significant technical problem. In addition, the reaction enthalpy necessary to perform the waste tire pyrolysis process (907.1 ± 40.0 kJ/kg) was determined from the combustion and formation enthalpies of waste tire and conversion products. Finally, a mass balance closure was performed showing an excellent reliability of the data obtained from the experimental campaign.

  18. [Brief overview of the guidelines for the use of 24 hour ambulatory blood pressure monitoring (ABPM)].

    Science.gov (United States)

    Shimada, Kazuyuki

    2014-08-01

    The guidelines for the use of ambulatory blood pressure monitoring published from Japanese Circulation Society in 2010 was briefly overviewed. The accuracy of devices now used in clinical practice in Japan is of sufficient grade. The thresholds for hypertension diagnosis based on ABPM have been determined with international concensus. The evaluation of ABPM data and the clinical indications for ABPM are suggested. Particularly, white-coat hypertension, masked hypertension, nocturnal hypertension, morning hypertension and diurnal blood pressure variation are conditions for which ABPM is very useful for the detection, treatment decision and follow-up. Hypertension treatment would be very much improved by the introduction of ABPM into clinical practice.

  19. Studies of jet fuel additives using the quartz crystal microbalance and pressure monitoring at 140 C

    Energy Technology Data Exchange (ETDEWEB)

    Zabarnick, S.; Grinstead, R.R. [Univ. of Dayton Research Institute, OH (United States)

    1995-05-01

    The quartz crystal microbalance (QCM) and pressure monitoring are used for the evaluation of jet fuel additives for the improvement of jet fuel thermal stability. The mechanisms of additive behavior are determined by measuring the time dependent deposition with the QCM and oxidation by pressure measurements. Studies at various additive concentrations permits the determination of optimum additive concentrations. Additive packages made of mixtures of antioxidants, detergent/dispersants, and metal deactivators are shown to yield good improvements in thermal stability over a wide range of jet fuel types.

  20. Recycling of car tires by means of Waterjet technologies

    Science.gov (United States)

    Holka, Henryk; Jarzyna, Tomasz

    2017-03-01

    An increasing number of used car tires poses a threat to the environment. Therefore they need to be recycled. In this work a decomposition method that involves applying a stream of water at very high pressure (to 600MPa) is presented. This method is based on the authors' own patent from 2010 and the results have been provided from two year-long tests and calculations This study includes many diagrams, images and calculations that have been used to develop the discussed method which is competitive for currently used ones.

  1. MORTAR WITH UNSERVICEABLE TIRE RESIDUES

    Directory of Open Access Journals (Sweden)

    J. A. Canova

    2009-01-01

    Full Text Available This study analyzes the effects of unserviceable tire residues on rendering mortar using lime and washed sand at a volumetric proportion of 1:6. The ripened composite was dried in an oven and combined with both cement at a volumetric proportion of 1:1.5:9 and rubber powder in proportional aggregate volumes of 6, 8, 10, and 12%. Water exudation was evaluated in the plastic state. Water absorption by capillarity, fresh shrinkage and mass loss, restrained shrinkage and mass loss, void content, flexural strength, and deformation energy under compression were evaluated in the hardened state. There was an improvement in the water exudation and water absorption by capillarity and drying shrinkage, as well as a reduction of the void content and flexural strength. The product studied significantly aided the water exudation from mortar and, capillary elevation in rendering.

  2. MORTAR WITH UNSERVICEABLE TIRE RESIDUES

    Directory of Open Access Journals (Sweden)

    José Aparecido Canova

    2009-12-01

    Full Text Available This study analyzes the effects of unserviceable tire residues on rendering mortar using lime and washed sand at a volumetric proportion of 1:6. The ripened composite was dried in an oven and combined with both cement at a volumetric proportion of 1:1.5:9 and rubber powder in proportional aggregate volumes of 6, 8, 10, and 12%. Water exudation was evaluated in the plastic state. Water absorption by capillarity, fresh shrinkage and mass loss, restrained shrinkage and mass loss, void content, flexural strength, and deformation energy under compression were evaluated in the hardened state. There was an improvement in the water exudation and water absorption by capillarity and drying shrinkage, as well as a reduction of the void content and flexural strength. The product studied significantly aided the water exudation from mortar and, capillary elevation in rendering.

  3. Using Crumb Rubber from Waste Tires to Reduce Road Traffic Noise

    Directory of Open Access Journals (Sweden)

    Frolova Olga

    2016-01-01

    Full Text Available The results of measurements of sound pressure levels on an experimental road section (road pavement with addition of crumb rubber from waste tires in Mala Ida village (Kosice region, Slovakia and on a road with stone mastic asphalt in Haniska village (Presov region, Slovakia are presented in the paper. The results obtained using statistical pass-by methods were compared and they confirmed that road surface with addition of crumb rubber from waste tires produced quieter pavement than stone mastic asphalt road pavement alone.

  4. Development and Validation of a Novel Cuff-Less Blood Pressure Monitoring Device

    Directory of Open Access Journals (Sweden)

    Naoki Watanabe, MD

    2017-12-01

    Full Text Available Ordinary cuff-based blood pressure–monitoring devices remain a technical limitation that disturbs activities of daily life. Here we report a novel system for the cuff-less blood pressure estimation (CLB that requires only 1 sensor for photoplethysmography. The present study is the first report to validate and assess the clinical application of the CLB in accordance with the latest wearable device standard (issued by the Institute of Electrical and Electronics Engineers, standard 1708-2014. Our CLB is expected to offer a flexible and wearable device that permits blood pressure monitoring in more continuous and stress-free settings.

  5. Ultrasonic Reflectometry for Monitoring the Effect of Pressure on Sludge Fouling of MF Membranes

    DEFF Research Database (Denmark)

    Jørgensen, Mads Koustrup; Kujundzic, Elmira; Greenberg, Alan

    Membrane fouling remains the key limitation for the widespread use of membrane bioreactors (MBR) for wastewater treatment. This constraint has led to an increasing number of studies that examine the influence of various operational parameters and physicochemical properties on fouling layer...... formation and characteristics. In other membrane applications real-time monitoring has proven to be useful by providing a more quantitative characterization of fouling layer formation [1]. One such technique, ultrasonic reflectometry (UR), has been successfully used to detect fouling formed by a wide range...... of the effect of pressure on the fouling layer structure. The ability of UR to detect and monitor sludge fouling was studied in a series of replicated experiments of 15, 30 and 60-min duration that used commercial microfiltration (MF) membranes at a transmembrane pressure of 15 kPa. By analyzing the peak...

  6. Feasibility of Telemetric Intracranial Pressure Monitoring in the Neuro Intensive Care Unit.

    Science.gov (United States)

    Lilja-Cyron, Alexander; Kelsen, Jesper; Andresen, Morten; Fugleholm, Kåre; Juhler, Marianne

    2018-05-03

    Intracranial pressure (ICP) monitoring is crucial in the management of acute neurosurgical conditions such as traumatic brain injury (TBI). However, pathological ICP may persist beyond the admission to the neuro intensive care unit (NICU). We investigated the feasibility of telemetric ICP monitoring in the NICU, as this technology provides the possibility of long-term ICP assessment beyond NICU discharge. In this prospective investigation, we implanted telemetric ICP sensors (Raumedic Neurovent-P-tel) instead of conventional, cabled ICP sensors in patients undergoing decompressive craniectomy. We recorded ICP curves, duration of ICP monitoring, signal quality, and complications. Seventeen patients were included (median age 55 years) and diagnoses were: severe TBI (8), malignant middle cerebral artery infarction (8), and spontaneous intracerebral hemorrhage (1). In total, 3015 h of ICP monitoring were performed, and the median duration of ICP monitoring was 188 h (interquartile range [IQR] 54-259). The ICP signal was lost 613 times (displacement of the reader unit on the skin) for a median of 1.5 min, corresponding to 0.8% of the total monitoring period. When the signal was lost, it could always be restored by realignment of the reader unit on the skin above the telemetric sensor. Sixteen of 17 patients survived the NICU admission, and ICP gradually decreased from 10.7 mm Hg (IQR 7.5-13.6) during the first postoperative day to 6.3 mm Hg (IQR 4.0-8.3) after 1 week in the NICU. All 17 implanted telemetric sensors functioned throughout the NICU admission, and no wound infections were observed. Therefore, telemetric ICP monitoring in an acute neurosurgical setting is feasible. Signal quality and stability are sufficient for clinical decision making based on mean ICP. The low sampling frequency (5 Hz) does not permit analysis of intracranial pulse wave morphology, but resolution is sufficient for calculation of derived indices such as the pressure reactivity

  7. Designing and Constructing Blood Flow Monitoring System to Predict Pressure Ulcers on Heel

    Directory of Open Access Journals (Sweden)

    Akbari H.

    2014-06-01

    Full Text Available Background: A pressure ulcer is a complication related to the need for the care and treatment of primarily disabled and elderly people. With the decrease of the blood flow caused by the pressure loaded, ulcers are formed and the tissue will be wasted with the passage of time. Objective: The aim of this study was to construct blood flow monitoring system on the heel tissue which was under external pressure in order to evaluate the tissue treatment in the ulcer. Methods: To measure the blood flow changes, three infrared optical transmitters were used at the distances of 5, 10, and 15 mm to the receiver. Blood flow changes in heels were assessed in pressures 0, 30, and 60 mmHg. The time features were extracted for analysis from the recorded signal by MATLAB software. Changes of the time features under different pressures were evaluated at the three distances by ANOVA in SPSS software. The level of significance was considered at 0.05. Results: In this study, 15 subjects, including both male and female, with the mean age of 54±7 participated. The results showed that the signal amplitude, power and absolute signal decreased significantly when pressure on the tissue increased in different layers (p<0.05. Heart rate only decreased significantly in pressures more than 30 mmHg (p=0.02. In pressures more than 30 mmHg, in addition to a decrease in the time features, the pattern of blood flow signal changed and it wasn’t the same as noload signal. Conclusion: By detecting the time features, we can reach an early diagnosis to prognosticate the degeneration of the tissue under pressure and it can be recommended as a method to predict bedsores in the heel.

  8. The importance of clinical monitoring for compliance with Continuous Positive Airway Pressure.

    Science.gov (United States)

    Pelosi, Lucas B; Silveira, Mariana L C; Eckeli, Alan L; Chayamiti, Emilia M P C; Almeida, Leila A; Sander, Heidi H; Küpper, Daniel S; Valera, Fabiana C P

    Obstructive sleep apnea syndrome is currently a public health problem of great importance. When misdiagnosed or improperly treated, it can lead to serious consequences on patients' quality of life. The gold standard treatment for cases of obstructive sleep apnea syndrome, especially in mild to severe and symptomatic cases, is continuous positive airway pressure therapy. Compliance with continuous positive airway pressure therapy is directly dependent on the active participation of the patient, which can be influenced by several factors. The objective of this study is to describe the factors related to compliance with continuous positive airway pressure therapy, and to analyze which associated factors directly influence the efficiency of the treatment. Patients who received continuous positive airway pressure therapy through the Municipal Health Department of the city of Ribeirão Preto were recruited. A structured questionnaire was administered to the patients. Compliance with continuous positive airway pressure therapy was assessed by average hours of continuous positive airway pressure therapy usage per night. Patients with good compliance (patients using continuous positive airway pressure therapy ≥4h/night) were compared to those with poor compliance (patients using <4h/night). 138 patients were analyzed: 77 (55.8%) were considered compliant while 61 (44.2%) were non-compliant. The comparison between the two groups showed that regular monitoring by a specialist considerably improved compliance with continuous positive airway pressure therapy (odds ratio, OR=2.62). Compliance with continuous positive airway pressure therapy is related to educational components, which can be enhanced with continuous and individualized care to patients with obstructive sleep apnea syndrome. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Acoustic emission monitoring during hydrotest of a thin wall pressure vessel

    International Nuclear Information System (INIS)

    Fontana, E.; Grugni, G.; Panzani, C.; Pirovano, B.; Possa, G.; Tonolini, F.

    1976-01-01

    Results are presented of the acoustic emission monitoring during hydrotests of a thin wall steel pressure vessel. Location of acoustic sources was based on longitudinal wave front detection. The careful calibration of the three sensors used for acoustic source location was found to be very useful, and allowed an accurate location error analysis. Acoustic emission in the hydrotests was found to be due mainly to stress release in weld seams

  10. Nurse-Driven Training Courses: Impact on Implementation of Ambulatory Blood Pressure Monitoring

    OpenAIRE

    F?lez-Carrob?, Estel; Sagarra-Ti?, Maria; Romero, Araceli; Rubio, Montserrat; Planas, Lourdes; P?rez-Lucena, Mar?a Jos?; Baiget, Montserrat; Cabista?, Cristina; F?lez, Jordi

    2013-01-01

    Background: Ambulatory blood pressure monitoring (ABPM) predicts cardiovascular risk and identifies white-coat and masked hypertension, efficacy of treatment and the circadian cycle of hypertensive patients. Objective: To analyze the effectiveness of ABPM implementation thoughtout a nurse-driven training program. Materials and Methodology: Twenty eight professionals were involved in the study carried out in the primary care center of the metropolitan area of Barcelona that serves 34,289 inhab...

  11. Processing Satellite Imagery To Detect Waste Tire Piles

    Science.gov (United States)

    Skiles, Joseph; Schmidt, Cynthia; Wuinlan, Becky; Huybrechts, Catherine

    2007-01-01

    A methodology for processing commercially available satellite spectral imagery has been developed to enable identification and mapping of waste tire piles in California. The California Integrated Waste Management Board initiated the project and provided funding for the method s development. The methodology includes the use of a combination of previously commercially available image-processing and georeferencing software used to develop a model that specifically distinguishes between tire piles and other objects. The methodology reduces the time that must be spent to initially survey a region for tire sites, thereby increasing inspectors and managers time available for remediation of the sites. Remediation is needed because millions of used tires are discarded every year, waste tire piles pose fire hazards, and mosquitoes often breed in water trapped in tires. It should be possible to adapt the methodology to regions outside California by modifying some of the algorithms implemented in the software to account for geographic differences in spectral characteristics associated with terrain and climate. The task of identifying tire piles in satellite imagery is uniquely challenging because of their low reflectance levels: Tires tend to be spectrally confused with shadows and deep water, both of which reflect little light to satellite-borne imaging systems. In this methodology, the challenge is met, in part, by use of software that implements the Tire Identification from Reflectance (TIRe) model. The development of the TIRe model included incorporation of lessons learned in previous research on the detection and mapping of tire piles by use of manual/ visual and/or computational analysis of aerial and satellite imagery. The TIRe model is a computational model for identifying tire piles and discriminating between tire piles and other objects. The input to the TIRe model is the georeferenced but otherwise raw satellite spectral images of a geographic region to be surveyed

  12. Monitoring of injected CO2 at two commercial geologic storage sites with significant pressure depletion and/or re-pressurization histories: A case study

    Directory of Open Access Journals (Sweden)

    Dayanand Saini

    2017-03-01

    The monitoring technologies that have been used/deployed/tested at both the normally pressured West Hastings and the subnormally pressured Bell Creek storage sites appear to adequately address any of the potential “out of zone migration” of injected CO2 at these sites. It would be interesting to see if any of the collected monitoring data at the West Hastings and the Bell Creek storage sites could also be used in future to better understand the viability of initially subnormally pressured and subsequently depleted and re-pressurized oil fields as secure geologic CO2 storage sites with relatively large storage CO2 capacities compared to the depleted and re-pressurized oil fields that were initially discovered as normally pressured.

  13. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  14. Investigation of the Effect of Dimple Bionic Nonsmooth Surface on Tire Antihydroplaning

    Directory of Open Access Journals (Sweden)

    Haichao Zhou

    2015-01-01

    Full Text Available Inspired by the idea that bionic nonsmooth surfaces (BNSS reduce fluid adhesion and resistance, the effect of dimple bionic nonsmooth structure arranged in tire circumferential grooves surface on antihydroplaning performance was investigated by using Computational Fluid Dynamics (CFD. The physical model of the object (model of dimple bionic nonsmooth surface distribution, hydroplaning model and SST k-ω turbulence model are established for numerical analysis of tire hydroplaning. By virtue of the orthogonal table L16(45, the parameters of dimple bionic nonsmooth structure design compared to the smooth structure were analyzed, and the priority level of the experimental factors as well as the best combination within the scope of the experiment was obtained. The simulation results show that dimple bionic nonsmooth structure can reduce water flow resistance by disturbing the eddy movement in boundary layers. Then, optimal type of dimple bionic nonsmooth structure is arranged on the bottom of tire circumferential grooves for hydroplaning performance analysis. The results show that the dimple bionic nonsmooth structure effectively decreases the tread hydrodynamic pressure when driving on water film and increases the tire hydroplaning velocity, thus improving tire antihydroplaning performance.

  15. Investigation of the Effect of Dimple Bionic Nonsmooth Surface on Tire Antihydroplaning.

    Science.gov (United States)

    Zhou, Haichao; Wang, Guolin; Ding, Yangmin; Yang, Jian; Zhai, Huihui

    2015-01-01

    Inspired by the idea that bionic nonsmooth surfaces (BNSS) reduce fluid adhesion and resistance, the effect of dimple bionic nonsmooth structure arranged in tire circumferential grooves surface on antihydroplaning performance was investigated by using Computational Fluid Dynamics (CFD). The physical model of the object (model of dimple bionic nonsmooth surface distribution, hydroplaning model) and SST k - ω turbulence model are established for numerical analysis of tire hydroplaning. By virtue of the orthogonal table L16(4(5)), the parameters of dimple bionic nonsmooth structure design compared to the smooth structure were analyzed, and the priority level of the experimental factors as well as the best combination within the scope of the experiment was obtained. The simulation results show that dimple bionic nonsmooth structure can reduce water flow resistance by disturbing the eddy movement in boundary layers. Then, optimal type of dimple bionic nonsmooth structure is arranged on the bottom of tire circumferential grooves for hydroplaning performance analysis. The results show that the dimple bionic nonsmooth structure effectively decreases the tread hydrodynamic pressure when driving on water film and increases the tire hydroplaning velocity, thus improving tire antihydroplaning performance.

  16. Tolerability of ambulatory blood pressure monitoring (ABPM) in cognitively impaired elderly.

    Science.gov (United States)

    Nesti, Nicola; Pieraccioli, Mariachiara; Mossello, Enrico; Sgrilli, Federica; Bulgaresi, Matteo; Crescioli, Elena; Biagini, Francesco; Caleri, Veronica; Tonon, Elisabetta; Cantini, Claudia; Biagini, Carlo A; Marchionni, Niccolò; Ungar, Andrea

    2014-12-01

    Recent guidelines have widened clinical indications for out-of-office blood pressure measurement, including home blood pressure monitoring and ambulatory blood pressure monitoring (ABPM), suggesting the latter as recommended method in cognitively impaired patients. There is, however, a widespread belief that ABPM could be poorly tolerated in dementia, often leading to withdraw from its use in these patients. To assess the actual tolerability of ABPM in a group of cognitively impaired elderly, affected by dementia or mild cognitive impairment (MCI). We evaluated 176 patients aged 65 + years, recruited in two different memory clinics, with a Mini Mental State Examination (MMSE) between 10 and 27. Behavioral and psychological symptoms were assessed with Neuropsychiatric Inventory (NPI). A patient was considered tolerant if able to keep the device on continuously for 24 h. The minimum number of correct measurements required was 70% of the predicted total number. 16% of patients wore the device for less than 24 h. Dividing the study population in tertiles of MMSE performance, 29% failed to tolerate the device in the lowest, 12% in the middle and 7% in the highest tertile (p ABPM proved a generally well-tolerated technique even in cognitively impaired elderly. Only a minority of subjects with poorer cognitive performances and greater behavioral symptoms did not tolerate the monitoring. Among most patients who failed to achieve the minimum number of measurements needed, the number of valid measurements was very close to the minimum required.

  17. Low parameter model to monitor bottom hole pressure in vertical multiphase flow in oil production wells

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2016-09-01

    Full Text Available The importance of the flow patterns through petroleum production wells proved for upstream experts to provide robust production schemes based on the knowledge about flow behavior. To provide accurate flow pattern distribution through production wells, accurate prediction/representation of bottom hole pressure (BHP for determining pressure drop from bottom to surface play important and vital role. Nevertheless enormous efforts have been made to develop mechanistic approach, most of the mechanistic and conventional models or correlations unable to estimate or represent the BHP with high accuracy and low uncertainty. To defeat the mentioned hurdle and monitor BHP in vertical multiphase flow through petroleum production wells, inventive intelligent based solution like as least square support vector machine (LSSVM method was utilized. The evolved first-break approach is examined by applying precise real field data illustrated in open previous surveys. Thanks to the statistical criteria gained from the outcomes obtained from LSSVM approach, the proposed least support vector machine (LSSVM model has high integrity and performance. Moreover, very low relative deviation between the model estimations and the relevant actual BHP data is figured out to be less than 6%. The output gained from LSSVM model are closed the BHP while other mechanistic models fails to predict BHP through petroleum production wells. Provided solutions of this study explicated that implies of LSSVM in monitoring bottom-hole pressure can indicate more accurate monitoring of the referred target which can lead to robust design with high level of reliability for oil and gas production operation facilities.

  18. Wheels and Tires: Understanding the Numbers on the Sides of Tires Might Lead to Longer Life Tires and Improved Driving Safety

    Science.gov (United States)

    Ritz, John M.

    2005-01-01

    Automotive wheels and tires require knowledge to understand their specifications and use. While the durability and useful life of tires have increased substantially over the last several decades, in all probability consumers will purchase a number of vehicle tires over their lifetime. Knowing how they are made and what the numbers mean will assist…

  19. Self-monitoring and self-management: new interventions to improve blood pressure control.

    Science.gov (United States)

    McCartney, David E; McManus, Richard J

    2016-11-01

    This article reviews recent developments in self-monitoring and self-management of hypertension aimed at the improvement of blood pressure (BP) control. There is an increasing body of evidence examining the effects of self-monitoring on BP control. Several landmark studies in recent years have demonstrated clinically relevant benefit from self-monitoring based interventions. Self-management of BP with self-titration has shown particular promise, as has self-monitoring combined with intensive health-care led support. There is a lack of evidence on the benefits of self-monitoring for those with important comorbidity such as coronary heart disease, chronic kidney disease, diabetes and previous stroke, and future research should be directed towards this. There is a growing body of evidence supporting the use of self-monitoring along with additional intervention including telemonitoring and self-titration in improving BP control. Further research is needed to understand which patients are likely to benefit most and how this is best integrated with routine care.

  20. Blood pressure self-monitoring in pregnancy: examining feasibility in a prospective cohort study.

    Science.gov (United States)

    Tucker, Katherine L; Taylor, Kathryn S; Crawford, Carole; Hodgkinson, James A; Bankhead, Clare; Carver, Tricia; Ewers, Elizabeth; Glogowska, Margaret; Greenfield, Sheila M; Ingram, Lucy; Hinton, Lisa; Khan, Khalid S; Locock, Louise; Mackillop, Lucy; McCourt, Christine; Pirie, Alexander M; Stevens, Richard; McManus, Richard J

    2017-12-28

    Raised blood pressure (BP) affects approximately 10% of pregnancies worldwide, and a high proportion of affected women develop pre-eclampsia. This study aimed to evaluate the feasibility of self-monitoring of BP in pregnancy in women at higher risk of pre-eclampsia. This prospective cohort study of self-monitoring BP in pregnancy was carried out in two hospital trusts in Birmingham and Oxford and thirteen primary care practices in Oxfordshire. Eligible women were those defined by the UK National Institute for Health and Care Excellence (NICE) guidelines as at higher risk of pre-eclampsia. A total of 201 participants were recruited between 12 and 16 weeks of pregnancy and were asked to take two BP readings twice daily three times a week through their pregnancy. Primary outcomes were recruitment, retention and persistence of self-monitoring. Study recruitment and retention were analysed with descriptive statistics. Survival analysis was used to evaluate the persistence of self-monitoring and the performance of self-monitoring in the early detection of gestational hypertension, compared to clinic BP monitoring. Secondary outcomes were the mean clinic and self-monitored BP readings and the performance of self-monitoring in the detection of gestational hypertension and pre-eclampsia compared to clinic BP. Of 201 women recruited, 161 (80%) remained in the study at 36 weeks or to the end of their pregnancy, 162 (81%) provided any home readings suitable for analysis, 148 (74%) continued to self-monitor at 20 weeks and 107 (66%) at 36 weeks. Self-monitored readings were similar in value to contemporaneous matched clinic readings for both systolic and diastolic BP. Of the 23 who developed gestational hypertension or pre-eclampsia and self-monitored, 9 (39%) had a raised home BP prior to a raised clinic BP. Self-monitoring of BP in pregnancy is feasible and has potential to be useful in the early detection of gestational hypertensive disorders but maintaining self-monitoring

  1. Quantitative Raman Spectroscopy to monitor microbial metabolism in situ under pressure

    Science.gov (United States)

    Picard, A.; Daniel, I.; Oger, P.

    2006-12-01

    Although high hydrostatic pressure (HHP) biotopes are ubiquitous on Earth, little is known about the metabolism of piezophile organisms. Cell culture under HHP can be technically challenging, and equipment- dependent. In addition, the depressurization step required for analysis can lead to erroneous data. Therefore, to understand how piezophile organisms react to pressure, it is crucial to be able to monitor their activity in situ under HHP. We developed the use of Quantitative Raman Spectroscopy (QRS, 1) to monitor in situ the metabolism of organic molecules. This technique is based on the specific spectral signature of an analyte from which its concentration can be deduced. An application of this technique to the monitoring of alcoholic fermentation by the piezotolerant micro-eucaryote Saccharomyces cerevisiae is presented. Ethanol fermentation from glucose was monitored during 24h from ambient P up to 100 MPa in the low- pressure Diamond Anvil Cell (lpDAC, 2). The experimental compression chamber consisted in a 300 μm-thick Ni gasket in which a 500 μm-diameter hole was drilled. Early-stationnary yeast cells were inoculated into fresh low-fluorescence medium containing 0.15 M of glucose. Ethanol concentration was determined in situ by QRS using the symmetric C-C stretching mode of ethanol at 878 cm-1 normalizing the data to the intensity of the sulfate S-O stretching mode at 980 cm-1. In our setup, the detection limit of ethanol is lower than 0.05 mM with a precision below 1%. At ambient P, ethanol production in the lpDAC and in control experiments proceeds with the same kinetics. Thus, yeast is not affected by its confinement. This is further confirmed by its ability to bud with a generation time similar to control experiments performed in glass tubes at ambient pressure inside the lpDAC. Ethanol production by yeast occurs to at least 65 MPa (3). At 10 MPa, fermentation proceeds 3 times faster than at ambient P. Fermentation rates decrease linearly from 20 to

  2. Benzodiazepine Consumption Is Associated With Lower Blood Pressure in Ambulatory Blood Pressure Monitoring (ABPM): Retrospective Analysis of 4938 ABPMs.

    Science.gov (United States)

    Mendelson, Nitsan; Gontmacher, Bella; Vodonos, Allina; Novack, Victor; Abu-AjAj, Muhammad; Wolak, Arik; Shalev, Haddar; Wolak, Talya

    2018-03-10

    The effect of chronic benzodiazepine use on blood pressure has not been documented. We aimed to evaluate whether regular benzodiazepine use can be associated to the results of ambulatory blood pressure monitoring (ABPM). A retrospective analysis of the ABPM database between 2009 and 2015 was performed. The study groups were divided according to benzodiazepine treatment at least 3 months before ABPM. Generalized estimating equation (GEE) model analysis was conducted to estimate the association between benzodiazepine treatment and ABPM test measurements. Multivariable COX regression survival analysis model for mortality and cardiovascular (CV) events was performed. A total of 4,938 ABPM studies were included in final analysis, 670 ABPMs of benzodiazepine-treated patients, and 4,268 of untreated patients. The benzodiazepine-treated group was significantly older, with a predominance of female patients, comprised more diabetic patients and consumed more antihypertensive medications. Adjustment for age, gender, diabetes mellitus, and number of antihypertensive medications, showed an association between benzodiazepine treatment and significantly lower ABPM measurements. When the analysis was split into those ≥60 years old and the other ABPM measurements only among ≥60 years old. Multivariable Cox regression survival analysis showed that regular benzodiazepine consumption was not associated with increased mortality or CV events (mean follow-up period of 42.4 ± 19.8 and 42.1 ± 20.0 months, respectively). Long-term use of benzodiazepines by ≥60 years old was independently associated with lower diastolic and systolic blood pressure in all parameters of ABPM, but not among younger patients.

  3. Using statistical process control for monitoring the prevalence of hospital-acquired pressure ulcers.

    Science.gov (United States)

    Kottner, Jan; Halfens, Ruud

    2010-05-01

    Institutionally acquired pressure ulcers are used as outcome indicators to assess the quality of pressure ulcer prevention programs. Determining whether quality improvement projects that aim to decrease the proportions of institutionally acquired pressure ulcers lead to real changes in clinical practice depends on the measurement method and statistical analysis used. To examine whether nosocomial pressure ulcer prevalence rates in hospitals in the Netherlands changed, a secondary data analysis using different statistical approaches was conducted of annual (1998-2008) nationwide nursing-sensitive health problem prevalence studies in the Netherlands. Institutions that participated regularly in all survey years were identified. Risk-adjusted nosocomial pressure ulcers prevalence rates, grade 2 to 4 (European Pressure Ulcer Advisory Panel system) were calculated per year and hospital. Descriptive statistics, chi-square trend tests, and P charts based on statistical process control (SPC) were applied and compared. Six of the 905 healthcare institutions participated in every survey year and 11,444 patients in these six hospitals were identified as being at risk for pressure ulcers. Prevalence rates per year ranged from 0.05 to 0.22. Chi-square trend tests revealed statistically significant downward trends in four hospitals but based on SPC methods, prevalence rates of five hospitals varied by chance only. Results of chi-square trend tests and SPC methods were not comparable, making it impossible to decide which approach is more appropriate. P charts provide more valuable information than single P values and are more helpful for monitoring institutional performance. Empirical evidence about the decrease of nosocomial pressure ulcer prevalence rates in the Netherlands is contradictory and limited.

  4. Numerical Simulation of the Ground Response to the Tire Load Using Finite Element Method

    Science.gov (United States)

    Valaskova, Veronika; Vlcek, Jozef

    2017-10-01

    Response of the pavement to the excitation caused by the moving vehicle is one of the actual problems of the civil engineering practice. The load from the vehicle is transferred to the pavement structure through contact area of the tires. Experimental studies show nonuniform distribution of the pressure in the area. This non-uniformity is caused by the flexible nature and the shape of the tire and is influenced by the tire inflation. Several tire load patterns, including uniform distribution and point load, were involved in the numerical modelling using finite element method. Applied tire loads were based on the tire contact forces of the lorry Tatra 815. There were selected two procedures for the calculations. The first one was based on the simplification of the vehicle to the half-part model. The characteristics of the vehicle model were verified by the experiment and by the numerical model in the software ADINA, when vehicle behaviour during the ride was investigated. Second step involved application of the calculated contact forces for the front axle as the load on the multi-layered half space representing the pavement structure. This procedure was realized in the software Plaxis and considered various stress patterns for the load. The response of the ground to the vehicle load was then analyzed. Axisymmetric model was established for this procedure. The paper presents the results of the investigation of the contact pressure distribution and corresponding reaction of the pavement to various load distribution patterns. The results show differences in some calculated quantities for different load patterns, which need to be verified by the experimental way when also ground response should be observed.

  5. Ambulatory and home blood pressure monitoring: gaps between clinical guidelines and clinical practice in Singapore

    Directory of Open Access Journals (Sweden)

    Setia S

    2017-07-01

    Full Text Available Sajita Setia,1 Kannan Subramaniam,2 Boon Wee Teo,3 Jam Chin Tay4 1Chief Medical Office, Medical Affairs, Pfizer Pte Ltd, Singapore; 2Global Medical Affairs, Asia Pacific Region, Pfizer Australia, West Ryde, New South Wales, Australia; 3Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; 4Department of General Medicine, Tan Tock Seng Hospital, Singapore Purpose: Out-of-office blood pressure (BP measurements (home blood pressure monitoring [HBPM] and ambulatory blood pressure monitoring [ABPM] provide important additional information for effective hypertension detection and management decisions. Therefore, out-of-office BP measurement is now recommended by several international guidelines. This study evaluated the practice and uptake of HBPM and ABPM among physicians from Singapore. Materials and methods: A sample of physicians from Singapore was surveyed between 8 September and 5 October 2016. Those included were in public or private practice had been practicing for ≥3 years, directly cared for patients ≥70% of the time, and treated ≥30 patients for hypertension per month. The questionnaire covered six main categories: general BP management, BP variability (BPV awareness/diagnosis, HBPM, ABPM, BPV management, and associated training needs. Results: Sixty physicians (30 general practitioners, 20 cardiologists, and 10 nephrologists were included (77% male, 85% aged 31–60 years, and mean 22-year practice. Physicians recommended HBPM and ABPM to 81% and 27% of hypertensive patients, respectively. HBPM was most often used to monitor antihypertensive therapy (88% of physicians and 97% thought that ABPM was useful for providing information on BPV. HBPM instructions often differed from current guideline recommendations in terms of frequency, number of measurements, and timing. The proportion of consultation time devoted to discussing HBPM and BPV was one-quarter or less for 73% of physicians, and

  6. Tire-road noise: an experimental study of tire and road design parameters

    NARCIS (Netherlands)

    Bekke, Dirk; Wijnant, Ysbrand H.; Weegerink, Thijs; de Boer, Andries

    2013-01-01

    It is widely known that road traffic noise has negative influences on human health. Hence, as tire-road noise is considered to be the most dominant cause of road traffic noise above 30-50 km/h, a lot of research is performed by the two involving industries: road authorities/manufacturers and tire

  7. A chest drainage system with a real-time pressure monitoring device.

    Science.gov (United States)

    Chen, Chih-Hao; Liu, Tsang-Pai; Chang, Ho; Huang, Tung-Sung; Liu, Hung-Chang; Chen, Chao-Hung

    2015-07-01

    Tube thoracostomy is a common procedure. A chest bottle may be used to both collect fluids and monitor the recovery of the chest condition. The presence of the "tidaling phenomenon" in the bottle can be reflective of the extent of patient's recovery. However, current practice essentially depends on gross observation of the bottle. The device used here is designed for a real-time monitoring of change in pleural pressure to allow clinicians to objectively determine when the lung has recovered, which is crucially important in order to judge when to remove the chest tube. The device is made of a pressure sensor with an operating range between -100 to +100 cmH2O and an amplifying using the "Wheatstone bridge" concept. Recording and analysis was performed with LABview software. The data can be shown in real-time on screen and also be checked retrospectively. The device was connected to the second part of a three-bottle drain system by a three-way connector. The test animals were two 40-kg pigs. We used a thoracoscopic procedure to create an artificial lung laceration with endoscopic scissors. Active air leaks could result in vigorous tidaling phenomenon up to 20 cmH2O. In the absence of gross tidaling phenomenon, the pressure changes were around 0.25 cmH2O. This real-time pleural pressure monitoring device can help clinicians objectively judge the extent of recovery of the chest condition. It can be used as an effective adjunct with the current chest drain system.

  8. Ambulatory and home blood pressure monitoring: gaps between clinical guidelines and clinical practice in Singapore.

    Science.gov (United States)

    Setia, Sajita; Subramaniam, Kannan; Teo, Boon Wee; Tay, Jam Chin

    2017-01-01

    Out-of-office blood pressure (BP) measurements (home blood pressure monitoring [HBPM] and ambulatory blood pressure monitoring [ABPM]) provide important additional information for effective hypertension detection and management decisions. Therefore, out-of-office BP measurement is now recommended by several international guidelines. This study evaluated the practice and uptake of HBPM and ABPM among physicians from Singapore. A sample of physicians from Singapore was surveyed between 8 September and 5 October 2016. Those included were in public or private practice had been practicing for ≥3 years, directly cared for patients ≥70% of the time, and treated ≥30 patients for hypertension per month. The questionnaire covered six main categories: general BP management, BP variability (BPV) awareness/diagnosis, HBPM, ABPM, BPV management, and associated training needs. Sixty physicians (30 general practitioners, 20 cardiologists, and 10 nephrologists) were included (77% male, 85% aged 31-60 years, and mean 22-year practice). Physicians recommended HBPM and ABPM to 81% and 27% of hypertensive patients, respectively. HBPM was most often used to monitor antihypertensive therapy (88% of physicians) and 97% thought that ABPM was useful for providing information on BPV. HBPM instructions often differed from current guideline recommendations in terms of frequency, number of measurements, and timing. The proportion of consultation time devoted to discussing HBPM and BPV was one-quarter or less for 73% of physicians, and only 55% said that they had the ability to provide education on HBPM and BPV. Patient inertia, poor patient compliance, lack of medical consultation time, and poor patient access to a BP machine were the most common challenges for implementing out-of-office BP monitoring. Although physicians from Singapore do recommend out-of-office BP measurement to patients with hypertension, this survey identified several important gaps in knowledge and clinical practice.

  9. [Ambulatory blood pressure monitoring (ABPM) and its usefulness in occupational medicine].

    Science.gov (United States)

    Czaja-Mitura, Izabela; Bortkiewicz, Alicja

    2012-01-01

    The application of long-term blood pressure monitoring (ABPM) in the occupational medicine practice, its advantages and disadvantages and the diagnostic and prognostic values of the parameters determined during the test were reviewed. The circumstances (e.g., social meeting, phone call) in which blood pressure value significantly differs from its resting value were identified. The methodology and reference values of systolic and diastolic blood pressure proposed by the European Society of Hypertension and the European Society of Cardiology were discussed as well as the recommended values of the blood pressure load. Ihe use of ABPM in the assessment of circadian blood pressure rhythm and the prognostic value of insufficient nocturnal drop (in non-dippers) or excessive nocturnal drop of ABP (in extreme dippers), and inverted circadian ABP variation (in reverse-dippers) was discussed. Attention was paid to the prognostic value of BP variability over short periods of time, which is specified in terms of standard deviation or coefficient of variance. This variability is considered as a factor capable of modifying the course, complications and prognosis of the hypertensive disease. The phenomena of "white coat hypertension" and masked hypertension were also described. It was demonstrated that the use of ABPM in occupational medicine is feasible, especially for preventive purposes, in workers exposed to different adverse work-related factors (noise, electromagnetic fields, shift work).

  10. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  11. Cost-effectiveness of ambulatory blood pressure monitoring in the management of hypertension.

    Science.gov (United States)

    Costa, Diogo; Peixoto Lima, Ricardo

    2017-02-01

    The prevalence of hypertension in Portugal is between 29.1% and 42.2%. International studies show that 13% of individuals have masked hypertension and 13% of diagnoses based on office blood pressure measurements are in fact white coat hypertension. More sensitive and specific blood pressure measuring methods could avoid costs associated with misdiagnosis. The aim of this study was to review the cost-effectiveness of ambulatory blood pressure monitoring (ABPM) compared to other methods in the management of hypertension. We performed a literature search in CMA Infobase, Guidelines Finder, National Guideline Clearinghouse, Bandolier, BMJ Clinical Evidence, the Cochrane Library, DARE, Medline, the Trip Database, SUMSearch and Índex das Revistas Médicas Portuguesas. We researched articles published between January 2005 and August 2015 in Portuguese, English and Spanish, using the MeSH terms "Hypertension", "Blood Pressure Monitoring, Ambulatory" and "Cost-Benefit Analysis" and the Portuguese search terms "Hipertensão", "Monitorização Ambulatorial da Pressão Arterial" and "Análise Custo-Benefício". Levels of evidence and grades of recommendation were attributed according to the Oxford Centre for Evidence-Based Medicine scale. Five hundred and twenty-five articles were identified. We included five original studies and one clinical practice guideline. All of them state that ABPM is the most cost-effective method. Two report better blood pressure control, and a Portuguese study revealed a saving of 23%. The evidence shows that ABPM is cost-effective, avoiding iatrogenic effects and reducing expenditure on treatment (grade of recommendation B). The included studies provide a solid basis, but further evidence of reproducibility is needed in research that is not based mainly on analytical models. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. European Society of Hypertension practice guidelines for ambulatory blood pressure monitoring.

    Science.gov (United States)

    Parati, Gianfranco; Stergiou, George; O'Brien, Eoin; Asmar, Roland; Beilin, Lawrence; Bilo, Grzegorz; Clement, Denis; de la Sierra, Alejandro; de Leeuw, Peter; Dolan, Eamon; Fagard, Robert; Graves, John; Head, Geoffrey A; Imai, Yutaka; Kario, Kazuomi; Lurbe, Empar; Mallion, Jean-Michel; Mancia, Giuseppe; Mengden, Thomas; Myers, Martin; Ogedegbe, Gbenga; Ohkubo, Takayoshi; Omboni, Stefano; Palatini, Paolo; Redon, Josep; Ruilope, Luis M; Shennan, Andrew; Staessen, Jan A; vanMontfrans, Gert; Verdecchia, Paolo; Waeber, Bernard; Wang, Jiguang; Zanchetti, Alberto; Zhang, Yuqing

    2014-07-01

    Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physicians. The present article details the requirements and the methodological issues to be addressed for using ABPM in clinical practice, The clinical indications for ABPM suggested by the available studies, among which white-coat phenomena, masked hypertension, and nocturnal hypertension, are outlined in detail, and the place of home measurement of blood pressure in relation to ABPM is discussed. The role of ABPM in pharmacological, epidemiological, and clinical research is also briefly mentioned. Finally, the implementation of ABPM in practice is considered in relation to the situation of different countries with regard to the reimbursement and the availability of ABPM in primary care practices, hospital clinics, and pharmacies.

  13. Miniature Coplanar Implantable Antenna on Thin and Flexible Platform for Fully Wireless Intracranial Pressure Monitoring System

    Directory of Open Access Journals (Sweden)

    M. Waqas A. Khan

    2017-01-01

    Full Text Available Minimally invasive approach to intracranial pressure monitoring is desired for long-term diagnostics. The monitored pressure is transmitted outside the skull through an implant antenna. We present a new miniature (6 mm × 5 mm coplanar implant antenna and its integration on a sensor platform to establish a far-field data link for the sensor readout at distances of 0.5 to 1 meter. The implant antenna was developed using full-wave electromagnetic simulator and measured in a liquid phantom mimicking the dielectric properties of the human head. It achieved impedance reflection coefficient better than −10 dB from 2.38 GHz to 2.54 GHz which covers the targeted industrial, scientific, and medical band. Experiments resulted in an acceptable peak gain of approximately −23 dBi. The implant antenna was submerged in the liquid phantom and interfaced to a 0.5 mW voltage controlled oscillator. To verify the implant antenna performance as a part of the ICP monitoring system, we recorded the radiated signal strength using a spectrum analyzer. Using a half-wavelength dipole as the receiving antenna, we captured approximately −58.7 dBm signal at a distance of 1 m from the implant antenna which is well above for the reader with sensitivity of −80 dBm.

  14. A Synthesis on the Evolution of the Studded Tire

    National Research Council Canada - National Science Library

    Angerinos, Michael

    1998-01-01

    Ever since studded tires were flrst introduced, the advantages, disadvantages, and effects of studded tires on vehicles, drivers and pavement systems has been the center of research and controversy...

  15. Recycled tires as coarse aggregate in concrete pavement mixtures.

    Science.gov (United States)

    2013-07-01

    The reuse potential of tire chips as coarse aggregates in pavement concrete was examined in this research by : investigating the effects of low- and high-volume tire chips on fresh and hardened concrete properties. One concrete : control mixture was ...

  16. Federal Research on Recycled Tire Crumb Used on Playing Fields

    Science.gov (United States)

    Ground rubber is recovered from scrap tires or from the tire retreading process. It is used in road construction and in athletic and recreational applications,like ground cover under playground equipment, running track material, and as a soil additive.

  17. Direct monitoring of wind-induced pressure-pumping on gas transport in soil

    Science.gov (United States)

    Laemmel, Thomas; Mohr, Manuel; Schindler, Dirk; Schack-Kirchner, Helmer; Maier, Martin

    2017-04-01

    Gas exchange between soil and atmosphere is important for the biogeochemistry of soils and is commonly assumed to be governed by molecular diffusion. Yet a few previous field studies identified other gas transport processes such as wind-induced pressure-pumping to enhance soil-atmosphere fluxes significantly. However, since these wind-induced non-diffusive gas transport processes in soil often occur intermittently, the quantification of their contribution to soil gas emissions is challenging. To quantify the effects of wind-induced pressure-pumping on soil gas transport, we developed a method for in situ monitoring of soil gas transport. The method includes the use of Helium (He) as a tracer gas which was continuously injected into the soil. The resulting He steady-state concentration profile was monitored. Gas transport parameters of the soil were inversely modelled. We used our method during a field campaign in a well-aerated forest soil over three months. During periods of low wind speed, soil gas transport was modelled assuming diffusion as transport process. During periods of high wind speed, the previously steady diffusive He concentration profile showed temporary concentration decreases in the topsoil, indicating an increase of the effective gas transport rate in the topsoil up to 30%. The enhancement of effective topsoil soil gas diffusivity resulted from wind-induced air pressure fluctuations which are referred to as pressure-pumping. These air pressure fluctuations had frequencies between 0.1 and 0.01 Hz and amplitudes up to 10 Pa and occurred at above-canopy wind speeds greater than 5 m s-1. We could show the importance of the enhancement of the gas transport rate in relation with the wind intensity and corresponding air pressure fluctuations characteristics. We directly detected and quantified the pressure-pumping effect on gas transport in soil in a field study for the first time, and could thus validate and underpin the importance of this non

  18. Rubber - application of radiation to tire manufacture

    International Nuclear Information System (INIS)

    Hunt, J.D.; Alliger, G.

    1979-01-01

    Since the advent of commercial accelerators during the last several years capable of producing controllable electron beams of high energy, Firestone has devoted a considerable effort to the better understanding of the possible applications of such radiation to the production of tires or tire components. A number of chemical reactions can occur when elastomeric compounds are exposed to high energy waves, but crosslinking and degradation are the most important. The degree to which the crosslinking reaction predominates depends upon the nature of the rubber, compounding ingredients and the dosage. In general then, the effects achieved by the radiation of a rubber are quite similar to those resulting from heat. However, radiation cure or precure of compounds offers the advantage that the degree of crosslinking can be better controlled. Uniform crosslinking is possible since the high speed electrons penetrate uniformly throughout the sample. Curing with heat on the other hand may result in a greater degree of crosslinking on the surface of the sample than the center because of low heat conductivity. In general, radiation can be used to advantage to crosslink partially rubber tire components so that they retain better their shape and dimension during tire assembly and final cure or vulcanization. Added advantages of radiation precure include: a reduction of material usage, substitution of synthetic for natural rubber without loss in strength and the fact that partially crosslinked components will not thin out or become displaced during construction and vulcanization of the tire. (author)

  19. Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Kang, Yuan-Yuan; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2013-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure (BP) monitor A&D UA-1020 with two different-shaped cuffs for home BP monitoring according to the British Hypertension Society (BHS) Protocol. We recruited individuals for each of the two cuffs (D-ring and cylindrical) until there were 85 eligible participants (255 pairs of comparisons) and their BP could meet the BP distribution requirements specified by the BHS Protocol. For each participant, we sequentially measured the systolic and diastolic BP using a mercury sphygmomanometer (two observers) and the UA-1020 device (one supervisor). For the D-ring cuff, the device achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 87, and 96%, respectively, for systolic BP, and 70, 90, and 99%, respectively, for diastolic BP. The average (±SD) of the device-observer differences was -0.2±7.3 mmHg (P=0.64) and 1.7±5.8 mmHg (P<0.0001) for systolic and diastolic BP, respectively. For the cylindrical cuff, the device also achieved grade A. The percentage of BP differences within 5, 10, and 15 mmHg was 67, 88, and 97%, respectively, for systolic BP and 64, 89, and 98%, respectively, for diastolic BP. The average of the device-observer differences was -0.1±7.0 mmHg (P=0.89) and 2.0±6.3 mmHg (P<0.0001) for systolic and diastolic BP, respectively. The UA-1020 device has passed the requirements of the BHS Protocol with both the D-ring and the cylindrical cuffs, and hence can be recommended for home use in adults.

  20. Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system

    International Nuclear Information System (INIS)

    Li, X. Allen; Stepaniak, Christopher; Gore, Elizabeth

    2006-01-01

    This work introduces a gating technique that uses 4DCT to determine gating parameters and to plan gated treatment, and employs a Siemens linear accelerator to deliver the gated treatment. Because of technology incompatibility, the 4DCT scanner (LightSpeed, GE) and the Siemens accelerator require two different motion-monitoring systems. The motion monitoring system (AZ-773V, Anzai Med.) used for the gated delivery utilizes a pressure sensor to detect the external respiratory motion (pressure change) in real time. Another system (RPM, Varian) used for the 4DCT scanner (LightSpeed, GE) is based on an infrared camera to detect motion of external markers. These two motion monitoring systems (RPM and Anzai systems) were found to correlate well with each other. The depth doses and profile measured for gated delivery (with a duty cycle of 25% or 50%) were found to agree within 1.0% with those measured for ungated delivery, indicating that gating did not significantly alter beam characteristics. The measurement verified also that the MU linearity and beam output remained unchanged (within 0.3%). A practical method of using 4DCT to plan a gated treatment was developed. The duty cycle for either phase or amplitude gating can be determined based on 4DCT with consideration of set-up error and delivery efficiency. The close-loop measurement involving the entire gating process (imaging, planning, and delivery) showed that the measured isodose distributions agreed with those intended, validating the accuracy and reliability of the gating technique. Based these observations, we conclude that the gating technique introduced in this work, integrating Siemens linear accelerator and Anzai pressure sensor device with GE/Varian RPM 4DCT, is reliable and effective, and it can be used clinically to account for respiratory motion during radiation therapy

  1. Continuous monitoring of natural ventilation pressure at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Loomis, I.M.; Wallace, K.G.

    1993-01-01

    The Waste Isolation Pilot Plant (WIPP) is a US Department of Energy research and development facility designed to demonstrate the permanent, safe disposal of US defense-generated transuranic waste. The waste storage horizon is 655 m (2150 ft) below surface in bedded salt. To date the WIPP project has not emplaced any waste. There are three intake shafts used to supply air to the underground. All air is exhausted through a single return shaft. The total design airflow during normal operations is 200 m 3 /s (424,000 cfm). The ventilation system is designed to provide separate air splits to construction, experimental, and storage activities. Separation is achieved by isolating the storage circuit from the construction or experimental circuits with bulkheads. Any air leakage must be towards the storage area of the facility. Field studies have shown that the pressure differential necessary to maintain the correct leakage direction is susceptible to the effects of natural ventilation; therefore, extensive studies and analyses have been conducted to quantify the natural ventilation effects on the WIPP underground airflow system. A component of this work is a monitoring system designed to measure the air properties necessary for calculation of the natural ventilation pressure (NVP). This monitoring system consists of measuring dry bulb temperature, relative humidity, and barometric pressure at strategic location on surface and underground. The psychometric parameters of the air are measured every fifteen minutes. From these data, trends can be determined showing the impact of NVP on the ventilation system during diurnal variations in surface climate. Both summer and winter conditions have been studied. To the author's knowledge this is the first reported instance of automatic and continuous production of time and temperature variant NVPs. This paper describes the results of the initial monitoring study

  2. Cuff-less PPG based continuous blood pressure monitoring: a smartphone based approach.

    Science.gov (United States)

    Gaurav, Aman; Maheedhar, Maram; Tiwari, Vijay N; Narayanan, Rangavittal

    2016-08-01

    Cuff-less estimation of systolic (SBP) and diastolic (DBP) blood pressure is an efficient approach for non-invasive and continuous monitoring of an individual's vitals. Although pulse transit time (PTT) based approaches have been successful in estimating the systolic and diastolic blood pressures to a reasonable degree of accuracy, there is still scope for improvement in terms of accuracies. Moreover, PTT approach requires data from sensors placed at two different locations along with individual calibration of physiological parameters for deriving correct estimation of systolic and diastolic blood pressure (BP) and hence is not suitable for smartphone deployment. Heart Rate Variability is one of the extensively used non-invasive parameters to assess cardiovascular autonomic nervous system and is known to be associated with SBP and DBP indirectly. In this work, we propose a novel method to extract a comprehensive set of features by combining PPG signal based and Heart Rate Variability (HRV) related features using a single PPG sensor. Further, these features are fed into a DBP feedback based combinatorial neural network model to arrive at a common weighted average output of DBP and subsequently SBP. Our results show that using this current approach, an accuracy of ±6.8 mmHg for SBP and ±4.7 mmHg for DBP is achievable on 1,750,000 pulses extracted from a public database (comprising 3000 people). Since most of the smartphones are now equipped with PPG sensor, a mobile based cuff-less BP estimation will enable the user to monitor their BP as a vital parameter on demand. This will open new avenues towards development of pervasive and continuous BP monitoring systems leading to an early detection and prevention of cardiovascular diseases.

  3. Implementation of Out-of-Office Blood Pressure Monitoring in the Netherlands

    Science.gov (United States)

    Carrera, Pricivel M.; Lambooij, Mattijs S.

    2015-01-01

    Abstract Out-of-office blood pressure monitoring is promoted by various clinical guidelines toward properly diagnosing and effectively managing hypertension and engaging the patient in their care process. In the Netherlands, however, the Dutch cardiovascular risk management (CVRM) guidelines do not explicitly prescribe 24-hour ambulatory blood pressure measurement (ABPM) and home BP measurement (HBPM). The aim of this descriptive study was to develop an understanding of patients’ and physicians’ acceptance and use of out-of-office BP monitoring in the Netherlands given the CVRM recommendations. Three small focus group discussions (FGDs) with patients and 1 FGD with physicians were conducted to explore the mechanisms behind the acceptance and use of out-of-office BP monitoring and reveal real-world challenges that limit the implementation of out-of-office BP monitoring methods. To facilitate the FGDs, an analytical framework based on the technology acceptance model (TAM), the theory of planned behavior and the model of personal computing utilization was developed to guide the FGDs and analysis of the transcriptions of each FGD. ABPM was the out-of-office BP monitoring method prescribed by physicians and used by patients. HBPM was not offered to patients even with patients’ feedback of poor tolerance of ABPM. Even as there was little awareness about HBPM among patients, there were a few patients who owned and used sphygmomanometers. Patients professed and seemed to exhibit self-efficacy, whereas physicians had reservations about (all of their) patients’ self-efficacy in properly using ABPM. Since negative experience with ABPM impacted patients’ acceptance of ABPM, the interaction of factors that determined acceptance and use was found to be dynamic among patients but not for physicians. In reference to the CVRM guidelines, physicians implemented out-of-office BP monitoring but showed a strong preference for ABPM even where there is poor tolerance of the

  4. Home blood-pressure monitoring in a hypertensive pregnant population: cost minimisation study.

    Science.gov (United States)

    Xydopoulos, G; Perry, H; Sheehan, E; Thilaganathan, B; Fordham, R; Khalil, A

    2018-03-08

    Traditional monitoring of blood pressure in hypertensive pregnant women requires frequent visits to the maternity outpatient services. Home blood-pressure monitoring (HBPM) could offer a cost-saving alternative that is acceptable to patients. The main objective of this study was to undertake a health economic analysis of HBPM compared with traditional monitoring in hypertensive pregnant women. This was a case-control study. Cases were pregnant women with hypertension who had HBPM with or without the adjunct of a smartphone app, via a specially designed pathway. The control group were managed as per existing hospital guidelines. Specific outcome measures were the number of outpatient visits, inpatient bed stays and investigations performed. Maternal, fetal and neonatal adverse outcomes were also recorded. Health economic analysis was performed using two methods: direct cost comparison of the study dataset and process scenario modelling. There were 108 women in the HBPM group, of whom 29 recorded their results on the smartphone app (App-HBPM) and 79 in their notes (Non-app HBPM). The control group comprised of 58 patients. There were significantly more women with chronic hypertension in the HBPM group (49.1% vs 25.9%, P = 0.004). The HBPM group had significantly longer duration of monitoring (9 weeks vs 5 weeks P = 0.004) and started monitoring from an earlier gestation (30 weeks vs 33.6 weeks, P = 0.001). Despite these differences, the mean saving per week for HBPM compared with the control group was £200.69. For the App-HBPM cohort, the saving per week compared with the control group was £286.53. The process modelling method predicted savings of between £98.32 and £245.80 per week using HBPM compared to the traditional monitoring. HBPM in hypertensive pregnancies appears to be cost-saving compared with traditional monitoring, without compromising maternal, fetal or neonatal safety. Larger studies are required to confirm these findings. This article is

  5. Stability Control of Vehicle Emergency Braking with Tire Blowout

    OpenAIRE

    Chen, Qingzhang; Liu, Youhua; Li, Xuezhi

    2014-01-01

    For the stability control and slowing down the vehicle to a safe speed after tire failure, an emergency automatic braking system with independent intellectual property is developed. After the system has received a signal of tire blowout, the automatic braking mode of the vehicle is determined according to the position of the failure tire and the motion state of vehicle, and a control strategy for resisting tire blowout additional yaw torque and deceleration is designed to slow down vehicle to...

  6. Simulation of Thermal Signature of Tires and Tracks

    Science.gov (United States)

    2012-08-01

    the body-ply is a linear elastic material. To facilitate the analysis, the tire was divided into Tread and Sidewall by the dash line as shown in...only one element is assigned through the thickness of the tire . Therefore, the thickness of the element is the same as the thickness of the tire ...to the whole part of the 3D full tire in the thermal analysis. The average strain energy density for each part ( tread or sidewall) in the cross

  7. Proceedings of Two Symposia on Nondestructive Testing of Tires

    Science.gov (United States)

    1978-05-01

    understanding of this tire inspection area. But this better technical understanding will not guar - antee the success of either the industry or...control. Tires with very dark sur- face may be sprayed with talcum powder to improve their reflectance. Depending upon tire type and the required tire...products there has been a tendency to use some natural or synthetic cross-linking polymer gums which under extended heat conditions have tended to

  8. SMART MONITORING AND DECISION MAKING FOR REGULATING ANNULUS BOTTOM HOLE PRESSURE WHILE DRILLING OIL WELLS

    Directory of Open Access Journals (Sweden)

    M. P. Vega

    Full Text Available Abstract Real time measurements and development of sensor technology are research issues associated with robustness and safety during oil well drilling operations, making feasible the diagnosis of problems and the development of a regulatory strategy. The major objective of this paper is to use an experimental plant and also field data, collected from a basin operation, offshore Brazil, for implementing smart monitoring and decision making, in order to assure drilling inside operational window, despite the commonly observed disturbances that produce fluctuations in the well annulus bottom hole pressure. Using real time measurements, the performance of a continuous automated drilling unit is analyzed under a scenario of varying levels of rate of penetration; aiming pressure set point tracking (inside the operational drilling window and also rejecting kick, a phenomenon that occurs when the annulus bottom hole pressure is inferior to the porous pressure, producing the migration of reservoir fluids into the annulus region. Finally, an empirical model was built, using real experimental data from offshore Brazil basins, enabling diagnosing and regulating a real drilling site by employing classic and advanced control strategies.

  9. Real-time combustion control and diagnostics sensor-pressure oscillation monitor

    Science.gov (United States)

    Chorpening, Benjamin T [Morgantown, WV; Thornton, Jimmy [Morgantown, WV; Huckaby, E David [Morgantown, WV; Richards, George A [Morgantown, WV

    2009-07-14

    An apparatus and method for monitoring and controlling the combustion process in a combustion system to determine the amplitude and/or frequencies of dynamic pressure oscillations during combustion. An electrode in communication with the combustion system senses hydrocarbon ions and/or electrons produced by the combustion process and calibration apparatus calibrates the relationship between the standard deviation of the current in the electrode and the amplitudes of the dynamic pressure oscillations by applying a substantially constant voltage between the electrode and ground resulting in a current in the electrode and by varying one or more of (1) the flow rate of the fuel, (2) the flow rate of the oxidant, (3) the equivalence ratio, (4) the acoustic tuning of the combustion system, and (5) the fuel distribution in the combustion chamber such that the amplitudes of the dynamic pressure oscillations in the combustion chamber are calculated as a function of the standard deviation of the electrode current. Thereafter, the supply of fuel and/or oxidant is varied to modify the dynamic pressure oscillations.

  10. [Clinical utility of home blood pressure monitoring in patients under treatment].

    Science.gov (United States)

    Bauk, L; Costa, H A; Caligiuri, S I

    2015-01-01

    A low number of patients who are treated with antihypertensive drugs achieve therapeutic goals. Home blood pressure monitoring is an excellent tool for studying this population. To determine the prevalence of patients with controlled and uncontrolled hypertension, as well as white-coat-effect and masked hypertension, and to evaluate the relationship with target organ damage in different groups. Blood pressure readings were performed simultaneously in the clinic and in the home using the same validated oscillometric equipment on 83 hypertensive patients on treatment with 2 or more antihypertensive drugs. They were then classified into 4 groups according to the cut-off values of the clinic and home blood pressure measurements. Left ventricular mass index, carotid intima media thickness, and microalbuminuria as markers of target organ damage, were also evaluated. Controlled blood pressure was present in 32.5%, 30.2% had sustained hypertension. The white coat effect was seen in 26.5%, while 10.8% were masked uncontrolled hypertension. Left ventricular mass index was higher in patients with no ambulatory control compared to controlled patients, and carotid IMT was also higher too in uncontrolled and white coat effect groups than controlled patients. More than one third of our patients who were treated with 2 or more drugs were not properly controlled, and they had significantly greater target organ damage than controlled patients. Copyright © 2014 SEHLELHA. Published by Elsevier Espana. All rights reserved.

  11. A pressure-sensitive carbon black cement composite for traffic monitoring

    KAUST Repository

    Monteiro, A.O.

    2017-08-17

    Recent advances in nanotechnology have guided the development of a new generation of multifunctional construction materials. An example of this are cement-based composites, some of which can be used not just to pave roads but also to monitor them. A cement composite, integrating a carbon black (CB) filler, was used as a piezoresistive sensor to identify different cyclic compressive loadings, at temperatures ranging from 15°C to 45°C. The mechanical essays were performed under realistic conditions using 600cm3 specimens and uniaxial loads typical of automobile traffic. A linear and reversible pressure-sensing performance was found with gauge factors ranging from 40 to 60. Overall, these results show that CB/cement composites can act as stress-sensitive materials for traffic monitoring.

  12. Home blood pressure monitoring, secure electronic messaging and medication intensification for improving hypertension control: a mediation analysis.

    Science.gov (United States)

    Ralston, J D; Cook, A J; Anderson, M L; Catz, S L; Fishman, P A; Carlson, J; Johnson, R; Green, B B

    2014-01-01

    We evaluated the role of home monitoring, communication with pharmacists, medication intensification, medication adherence and lifestyle factors in contributing to the effectiveness of an intervention to improve blood pressure control in patients with uncontrolled essential hypertension. We performed a mediation analysis of a published randomized trial based on the Chronic Care Model delivered over a secure patient website from June 2005 to December 2007. Study arms analyzed included usual care with a home blood pressure monitor and usual care with home blood pressure monitor and web-based pharmacist care. Mediator measures included secure messaging and telephone encounters; home blood pressure monitoring; medications intensification and adherence and lifestyle factors. Overall fidelity to the Chronic Care Model was assessed with the Patient Assessment of Chronic Care (PACIC) instrument. The primary outcome was percent of participants with blood pressure (BP) <140/90 mm Hg. At 12 months follow-up, patients in the web-based pharmacist care group were more likely to have BP <140/90 mm Hg (55%) compared to patients in the group with home blood pressure monitors only (37%) (p = 0.001). Home blood pressure monitoring accounted for 30.3% of the intervention effect, secure electronic messaging accounted for 96%, and medication intensification for 29.3%. Medication adherence and self-report of fruit and vegetable intake and weight change were not different between the two study groups. The PACIC score accounted for 22.0 % of the main intervention effect. The effect of web-based pharmacist care on improved blood pressure control was explained in part through a combination of home blood pressure monitoring, secure messaging, and antihypertensive medication intensification.

  13. The Use of Ambulatory Blood Pressure Monitoring Among Medicare Beneficiaries in 2007-2010

    OpenAIRE

    Shimbo, Daichi; Kent, Shia T; Diaz, Keith M; Huang, Lei; Viera, Anthony J; Kilgore, Meredith; Oparil, Suzanne; Muntner, Paul

    2014-01-01

    The US Centers for Medicaid and Medicare Services reimburses ambulatory blood pressure monitoring (ABPM) for suspected white coat hypertension. We estimated ABPM use between 2007 and 2010 among a 5% random sample of Medicare beneficiaries (≥ 65 years). In 2007, 2008, 2009 and 2010, the percentage of beneficiaries with ABPM claims was 0.10%, 0.11%, 0.10%, and 0.09% respectively. A prior diagnosis of hypertension was more common among those with versus without an ABPM claim (77.7% versus 47.0%)...

  14. NASA Prototype All Composite Tank Cryogenic Pressure Tests to Failure with Structural Health Monitoring

    Science.gov (United States)

    Werlink, Rudolph J.; Pena, Francisco

    2015-01-01

    This Paper will describe the results of pressurization to failure of 100 gallon composite tanks using liquid nitrogen. Advanced methods of health monitoring will be compared as will the experimental data to a finite element model. The testing is wholly under NASA including unique PZT (Lead Zirconate Titanate) based active vibration technology. Other technologies include fiber optics strain based systems including NASA AFRC technology, Acoustic Emission, Acellent smart sensor, this work is expected to lead to a practical in-Sutu system for composite tanks.

  15. Acoustic emission monitoring during hydrotests of a thin wall pressure vessel

    International Nuclear Information System (INIS)

    Fontana, E.; Grugni, G.; Panzani, C.; Pirovano, B.; Possa, G.; Tonolini, F.

    1975-01-01

    The results are presented of an acoustic emission monitoring performed during hydrotests of a thin wall steel pressure vessel. The location of acoustic sources was based on longitudinal wave front detection. The careful calibration of the three sensors instrumentation system used for acoustic source location was found to be useful, and alllowed an accurate location error analysis. Acoustic emission in the hydrotests was found to be mainly due to stress release in weld seams. (Fontana, E.; Grugni, G.; Panzani, C.; Pirovano, B.; Possa, G.; Tonolini, F.)

  16. Assessment of the usability of a digital learning technology prototype for monitoring intracranial pressure

    Directory of Open Access Journals (Sweden)

    Lilian Regina de Carvalho

    Full Text Available ABSTRACT Objective: to assess the usability of a digital learning technology prototype as a new method for minimally invasive monitoring of intracranial pressure. Method: descriptive study using a quantitative approach on assessing the usability of a prototype based on Nielsen's ten heuristics. Four experts in the area of Human-Computer interaction participated in the study. Results: the evaluation delivered eight violated heuristics and 31 usability problems in the 32 screens of the prototype. Conclusion: the suggestions of the evaluators were critical for developing an intuitive, user-friendly interface and will be included in the final version of the digital learning technology.

  17. The application of acoustic emission measurements on laboratory testpieces to large scale pressure vessel monitoring

    International Nuclear Information System (INIS)

    Ingham, T.; Dawson, D.G.

    1975-01-01

    A test pressure vessel containing 4 artificial defects was monitored for emission whilst pressure cycling to failure. Testpieces cut from both the failed vessel and from as-rolled plate material were tested in the laboratory. A marked difference in emission characteristics was observed between plate and vessel testpieces. Activity from vessel material was virtually constant after general yield and emission amplitudes were low. Plate testpieces showed maximum activity at general yield and more frequent high amplitude emissions. An attempt has been made to compare the system sensitivities between the pressure vessel test and laboratory tests. In the absence of an absolute calibration device, system sensitivities were estimated using dummy signals generated by the excitation of an emission sensor. The measurements have shown an overall difference in sensitivity between vessel and laboratory tests of approximately 25db. The reduced sensitivity in the vessel test is attributed to a combination of differences in sensors, acoustic couplant, attenuation, and dispersion relative to laboratory tests and the relative significance of these factors is discussed. Signal amplitude analysis of the emissions monitored from laboratory testpieces showed that, whith losses of the order of 25 to 30db, few emissions would be detected from the pressure vessel test. It is concluded that no reliable prediction of acoustic behaviour of a structure may be made from laboratory test unless testpieces of the actual structural material are used. A considerable improvement in detection sensitivity, is also required for reliable detection of defects in low strength ductile materials and an absolute method of system calibration is required between tests

  18. [Intracranial pressure monitoring and CSF dynamics in patients with neurological disorders: indications and practical considerations].

    Science.gov (United States)

    Poca, M; Sahuquillo, J

    2001-01-01

    The study of cerebrospinal fluid (CSF) dynamics is central to the diagnosis of adult chronic hydrocephalus (ACH). At present, many neurology and neurosurgery departments use one or more tests to guide diagnosis of this syndrome and to predict patient response to shunting. In specialised centres, the study of CSF dynamics is combined with continuous intracranial pressure (ICP) monitoring. Determination of several variables of CSF dynamics and definitions of qualitative and quantitative characteristics of ICP can be used to establish whether the hydrocephalus is active, compensated or arrested. CSF dynamics and ICP monitoring can also be used to check the correct functioning of the shunt and can be of use in the clinical management of patients with pseudotumor cerebri. Moreover, ICP monitoring is used to guide the treatment of several acute neurological processes. The aim of this review is to describe the fundamentals of CSF dynamics studies and the bases of continuous ICP monitoring. The advantages and disadvantages of several hydrodynamic tests that can be performed by lumbar puncture, as well as the normal and abnormal characteristics of an ICP recording, are discussed.

  19. Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effects

    Directory of Open Access Journals (Sweden)

    Wu J

    2013-08-01

    Full Text Available Jun Wu1, Wei He2, Wei-min Chen1, Lian Zhu21Key Laboratory of Optoelectronic Technology and Systems, 2State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing, People’s Republic of ChinaAbstract: The real-time monitoring of intracranial pressure (ICP is very important for craniocerebrally critically ill patients, but it is very difficult to realize long-time monitoring for the traditional invasive method, which very easily infects patients. Many noninvasive methods have emerged, but these have not been able to monitor ICP for long periods in real time, and they are not ready for clinical application. In order to realize long-time, online, real-time, noninvasive monitoring for ICP, a new method based on acoustoelasticity of ultrasound is herein proposed. Experimental models were devised to research the new method for experiment and simulation. Polymethyl methacrylate and hydrogel were adopted for the experiment, and their mechanical properties were very close to the real brain. A numerical solution for acoustoelasticity theory was acquired by simulating calculation based on a finite-element method. This was compared to the experimental value. The results showed a consistent match between theoretical solution and experimental value, with maximum error at most 5%. Thus, the effectiveness of the new method was verified. Theoretical and practical foundation is provided for this new method, and it could be used for animal experimentation or clinical testing in further research.Keywords: medical instruments, noninvasive, intracranial pressure, ultrasonic, acoustoelasticity, biomechanics

  20. The use of mixed pyrrhotite/pyrite catalysts for co-liquefaction of coal and waste rubber tires

    Energy Technology Data Exchange (ETDEWEB)

    Dadyburjor, D.B.; Zondlo, J.W.; Sharma, R.K. [West Virginia Univ., Morgantown, WV (United States)] [and others

    1995-12-31

    The overall objective of this research program is to determine the optimum processing conditions for tire/coal co-liquefaction. The catalysts used will be a ferric-sulfide-based materials, as well as promising catalysts from other consortium laboratories. The intent here is to achieve the maximum coal+tire conversion at the mildest conditions of temperature and pressure. Specific objectives include an investigation of the effects of time, temperature, pressure, catalyst and co-solvent on the conversion and product slate of the co-liquefaction. Accomplishments and conclusions are discussed.

  1. 49 CFR 229.75 - Wheels and tire defects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Wheels and tire defects. 229.75 Section 229.75....75 Wheels and tire defects. Wheels and tires may not have any of the following conditions: (a) A... two adjoining spots that are each two or more inches in length. (e) A seam running lengthwise that is...

  2. 76 FR 79114 - Tire Fuel Efficiency Consumer Information Program

    Science.gov (United States)

    2011-12-21

    ... car tires. The final rule also established reporting requirements for the generated performance... aspects of tire performance: rolling resistance, wet traction, and treadwear life.\\3\\ The final rule also... provide information indicating the relative performance of passenger car tires in the areas of treadwear...

  3. 78 FR 66655 - Consumer Information; Uniform Tire Quality Grading Standards

    Science.gov (United States)

    2013-11-06

    ... information indicating the relative performance of passenger car tires in the areas of treadwear, traction... [Docket No. NHTSA-2013-0120] RIN 2127-AL49 Consumer Information; Uniform Tire Quality Grading Standards...). ACTION: Interim final rule; request for comments. SUMMARY: The Uniform Tire Quality Grading Standards...

  4. Ground tire rubber as a stabilizer for subgrade soils.

    Science.gov (United States)

    2014-05-01

    Over 250 million scrap tires are generated annually in the U.S. Historically, a significant portion of these tires : have been processed into finely ground tire rubber (GTR), or crumb rubber, for use as an additive in hot mix asphalt : (HMA) pavement...

  5. Ground tire rubber as a stabilizer for subgrade soils : [summary].

    Science.gov (United States)

    2014-05-01

    Over 250 million scrap tires are generated : annually in the U.S. Historically, a significant : portion of these tires have been processed into : finely ground tire rubber (GTR), or crumb rubber, : for use as an additive in hot mix asphalt (HMA) : pa...

  6. 49 CFR 230.112 - Wheels and tires.

    Science.gov (United States)

    2010-10-01

    ... wheels mounted on the same axle shall not vary more than 1/4 inch. (d) Tire thickness. Wheels may not have tires with a minimum thickness less than that indicated in the table in this paragraph (d). When... the minimum thickness of tires may be as much below the limits specified earlier in this paragraph (d...

  7. Application of granulating of tires; Aplicaciones de granulado de NFUs

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez Justicia, A.

    2001-07-01

    At present, used tires are mainly used as fuel, retreading and granulating of tires. In this article. I will focus on the last option, talking about some of the multiple applications and going into detail of the making process of the granulation of used tires in a recycling plant. (Author)

  8. 75 FR 15893 - Tire Fuel Efficiency Consumer Information Program

    Science.gov (United States)

    2010-03-30

    ... how much the proposed consumer information program would affect consumer tire purchasing behavior and... 575 Tire Fuel Efficiency Consumer Information Program; Final Rule #0;#0;Federal Register / Vol. 75, No... 2127-AK45 Tire Fuel Efficiency Consumer Information Program AGENCY: National Highway Traffic Safety...

  9. Strength of mortar containing rubber tire particle

    Science.gov (United States)

    Jusoh, M. A.; Abdullah, S. R.; Adnan, S. H.

    2018-04-01

    The main focus in this investigation is to determine the strength consist compressive and tensile strength of mortar containing rubber tire particle. In fact, from the previous study, the strength of mortar containing waste rubber tire in mortar has a slightly decreases compare to normal mortar. In this study, rubber tire particle was replacing on volume of fine aggregate with 6%. 9% and 12%. The sample were indicated M0 (0%), M6 (6%), M9 (9%) and M12 (12%). In this study, two different size of sample used with cube 100mm x 100mm x 100mm for compressive strength and 40mm x 40mm x 160mm for flexural strength. Morphology test was conducted by using Scanning electron microscopic (SEM) were done after testing compressive strength test. The concrete sample were cured for day 3, 7 and 28 before testing. Results compressive strength and flexural strength of rubber mortar shown improved compare to normal mortar.

  10. Tire Development for Effective Transportation and Utilization of Used Tires, CRADA 01-N044, Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Susan M. Maley

    2004-03-31

    Scrap tires represent a significant disposal and recycling challenge for the United States. Over 280 million tires are generated on an annual basis, and several states have large stockpiles or abandoned tire piles that are slated for remediation. While most states have programs to address the accumulation and generation of scrap tires, most of these states struggle with creating and sustaining recycling or beneficial end use markets. One of the major issues with market development has been the costs associated with transporting and processing the tires into material for recycling or disposal. According to a report by the Rubber Manufactures Association tire-derived fuel (TDF) represents the largest market for scrap tires, and approximately 115 million tires were consumed in 2001 as TDF (U.S. Scrap Tire Markets, 2001, December 2002, www.rma.org/scraptires). This market is supported primarily by cement kilns, followed by various industries including companies that operate utility and industrial boilers. However the use of TDF has not increased and the amount of TDF used by boiler operators has declined. The work completed through this cooperative research and development agreement (CRADA) has shown the potential of a mobile tire shredding unit to economically produce TDF and to provide an alterative low cost fuel to suitable coal-fired power systems. This novel system addresses the economic barriers by processing the tires at the retailer, thereby eliminating the costs associated with hauling whole tires. The equipment incorporated into the design allow for small 1-inch chunks of TDF to be produced in a timely fashion. The TDF can then be co-fired with coal in suitable combustion systems, such as a fluidized bed. Proper use of TDF has been shown to boost efficiency and reduce emissions from power generation systems, which is beneficial to coal utilization in existing power plants. Since the original scope of work outlined in the CRADA could not be completed because

  11. A novel high pressure, high temperature vessel used to conduct long-term stability measurements of silicon MEMS pressure transducers

    Science.gov (United States)

    Wisniewiski, David

    2014-03-01

    The need to quantify and to improve long-term stability of pressure transducers is a persistent requirement from the aerospace sector. Specifically, the incorporation of real-time pressure monitoring in aircraft landing gear, as exemplified in Tire Pressure Monitoring Systems (TPMS), has placed greater demand on the pressure transducer for improved performance and increased reliability which is manifested in low lifecycle cost and minimal maintenance downtime through fuel savings and increased life of the tire. Piezoresistive (PR) silicon MEMS pressure transducers are the primary choice as a transduction method for this measurement owing to their ability to be designed for the harsh environment seen in aircraft landing gear. However, these pressure transducers are only as valuable as the long-term stability they possess to ensure reliable, real-time monitoring over tens of years. The "heart" of the pressure transducer is the silicon MEMS element, and it is at this basic level where the long-term stability is established and needs to be quantified. A novel High Pressure, High Temperature (HPHT) vessel has been designed and constructed to facilitate this critical measurement of the silicon MEMS element directly through a process of mechanically "floating" the silicon MEMS element while being subjected to the extreme environments of pressure and temperature, simultaneously. Furthermore, the HPHT vessel is scalable to permit up to fifty specimens to be tested at one time to provide a statistically significant data population on which to draw reasonable conclusions on long-term stability. With the knowledge gained on the silicon MEMS element, higher level assembly to the pressure transducer envelope package can also be quantified as to the build-effects contribution to long-term stability in the same HPHT vessel due to its accommodating size. Accordingly, a HPHT vessel offering multiple levels of configurability and robustness in data measurement is presented, along

  12. Impact of antihypertensive combination and monotreatments on blood pressure variability: assessment by old and new indices. Data from a large ambulatory blood pressure monitoring database.

    LENUS (Irish Health Repository)

    Parati, Gianfranco

    2014-06-01

    High 24-h ambulatory blood pressure (ABP) variability is associated with poor cardiovascular outcomes. We analysed a large ABP monitoring database containing data from hypertensive patients treated with telmisartan\\/amlodipine combination or various monotherapies with the aim of quantifying the 24-h distribution of blood pressure (BP) reduction by treatment through the smoothness index and of developing and testing a new treatment-on-variability index (TOVI) to quantify the effects of treatment on both mean BP and BP variability.

  13. Development of an Arm Phantom for Testing Non-Invasive Blood Pressure Monitors

    Science.gov (United States)

    Anderson-Jackson, LaTecia D.

    Approximately one in every three adults age 20 older are diagnosed with high blood pressure or hypertension. It is estimated that hypertension affects 78 million people in the United States, is equally prevalent in both men and woman (Crabtree, Stuart-Shor, & McAllister, 2013). In the United States, around 78% of people suffering from hypertension are aware of their condition, with only 68% using hypertensive medications to control their blood pressure (Writing Group et al., 2010). Clinically, blood pressure measurements may lack accuracy, which can be attributed to various factors, including device limitations, cuff mis-sizing and misplacement, white-coat effect, masked hypertension, and lifestyle factors. The development of an arm phantom to simulate physiologic properties of a human arm and arterial BP waveforms may allow us to better assess the accuracy of non-invasive blood pressure (NIBP) monitors. The objective of this study are to: (1) Develop an arm phantom to replicate physiological properties of the human arm, and (2) Incorporate the arm phantom into a mock circulatory flow loop to simulate different physiological blood pressure readings on the bench. A tissue mimicking material, styrene-ethylene-butylene-styrene (SEBS), a co-block polymer was used to develop the arm phantom for in-vitro testing. To determine the optimal mechanical properties for the arm phantom, individual arm components were isolated and tested. A protocol was developed to evaluate various components for optimal arm phantom development. Mechanical testing was conducted on 10%, 15%, and 20% SEBS gel samples for modulus of elasticity measurements in order to simulate physiological properties of the human arm. As a result of the SEBS polymer being a new material for this application, this investigation will contribute to resolving the limitations that occurred during experimentation. In this study, we demonstrated that although SEBS polymer may be an ideal material to use for simulating

  14. Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive).

    Science.gov (United States)

    Lakhal, Karim; Ehrmann, Stephan; Perrotin, Dominique; Wolff, Michel; Boulain, Thierry

    2013-11-01

    To assess whether invasive and non-invasive blood pressure (BP) monitoring allows the identification of patients who have responded to a fluid challenge, i.e., who have increased their cardiac output (CO). Patients with signs of circulatory failure were prospectively included. Before and after a fluid challenge, CO and the mean of four intra-arterial and oscillometric brachial cuff BP measurements were collected. Fluid responsiveness was defined by an increase in CO ≥10 or ≥15% in case of regular rhythm or arrhythmia, respectively. In 130 patients, the correlation between a fluid-induced increase in pulse pressure (Δ500mlPP) and fluid-induced increase in CO was weak and was similar for invasive and non-invasive measurements of BP: r² = 0.31 and r² = 0.29, respectively (both p area under the receiver-operating curve (AUC) of 0.82 (0.74-0.88), similar (p = 0.80) to that of non-invasive Δ500mlPP [AUC of 0.81 (0.73-0.87)]. Outside large gray zones of inconclusive values (5-23% for invasive Δ500mlPP and 4-35% for non-invasive Δ500mlPP, involving 35 and 48% of patients, respectively), the detection of responsiveness or unresponsiveness to fluid was reliable. Cardiac arrhythmia did not impair the performance of invasive or non-invasive Δ500mlPP. Other BP-derived indices did not outperform Δ500mlPP. As evidenced by large gray zones, BP-derived indices poorly reflected fluid responsiveness. However, in our deeply sedated population, a high increase in invasive pulse pressure (>23%) or even in non-invasive pulse pressure (>35%) reliably detected a response to fluid. In the absence of a marked increase in pulse pressure (<4-5%), a response to fluid was unlikely.

  15. New method for remote and repeatable monitoring of intraocular pressure variations.

    Science.gov (United States)

    Margalit, Israel; Beiderman, Yevgeny; Skaat, Alon; Rosenfeld, Elkanah; Belkin, Michael; Tornow, Ralf-Peter; Mico, Vicente; Garcia, Javier; Zalevsky, Zeev

    2014-02-01

    We present initial steps toward a new measurement device enabling high-precision, noncontact remote and repeatable monitoring of intraocular pressure (IOP)-based on an innovative measurement principle. Using only a camera and a laser source, the device measures IOP by tracking the secondary speckle pattern trajectories produced by the reflection of an illuminating laser beam from the iris or the sclera. The device was tested on rabbit eyes using two different methods to modify IOP: via an infusion bag and via mechanical pressure. In both cases, the eyes were stimulated with increasing and decreasing ramps of the IOP. As IOP variations changed the speckle distributions reflected back from the eye, data were recorded under various optical configurations to define and optimize the best experimental configuration for the IOP extraction. The association between the data provided by our proposed device and that resulting from controlled modification of the IOP was assessed, revealing high correlation (R2=0.98) and sensitivity and providing a high-precision measurement (5% estimated error) for the best experimental configuration. Future steps will be directed toward applying the proposed measurement principle in clinical trials for monitoring IOP with human subjects.

  16. Empirical Analysis of Pneumatic Tire Friction on Ice

    OpenAIRE

    Holley, Troy Nigel

    2010-01-01

    Pneumatic tire friction on ice is an under-researched area of tire mechanics. This study covers the design and analysis of a series of pneumatic tire tests on a flat-level ice road surface. The terramechanics rig of the Advanced Vehicle Dynamics Lab (AVDL) is a single-wheel test rig that allows for the experimental analysis of the forces and moments on a tire, providing directly the data for the drawbar pull of said tire, thus supporting the calculation of friction based on this data. This...

  17. A molecular dynamics (MD simulation on tire-aggregate friction

    Directory of Open Access Journals (Sweden)

    Fengyan Sun

    2017-07-01

    Full Text Available The friction between tire and road surface is fundamentally depending on the molecular forces. In this paper, the nanoscale 3D contact model is employed to investigate the tire-aggregate friction mechanism. The tire and aggregate micro-structure are both constructed to evaluate the microscopic performance of tire-aggregate friction influence. Simulation results show for a high velocity, the energy dissipation of sliding on crystal structure is small, which results in a small friction coefficient; temperature will have influences on the friction coefficient, and with the increasing of velocity, the effect will gradually reduce. Keywords: Tire, Aggregate, Friction coefficient, Microscopic mechanism, MD simulation

  18. Measuring service life and evaluating the quality of solid tires

    Directory of Open Access Journals (Sweden)

    Charoenyut Dechwayukul

    2010-08-01

    Full Text Available The objective of this research is to propose procedures for measuring service life and evaluating the quality of locallymade and used solid tires in Thailand. The solid tires were stressed and rotated until blowout on a drum-like test apparatuswhich is designed, constructed by the authors and equipped with laboratory instrumentation. Solid tires from five differentmanufacturers were selected for testing. We measured service life, length of time to tire failure, at three different loadingamplitudes and three different speeds on the testing drum. The service life of all specimens was studied and compared todetermine the possibility of using service life to evaluate the quality of a solid tire.

  19. Study on profile measurement of extruding tire tread by laser

    Science.gov (United States)

    Wang, LiangCai; Zhang, Wanping; Zhu, Weihu

    1996-10-01

    This paper presents a new 2D measuring system-profile measurement of extruding tire tread by laser. It includes the thickness measurement of extruding tire tread by laser and the width measurement of extruding tire tread using Moire Fringe. The system has been applied to process line of extruding tire tread. Two measuring results have been obtained. One is a standard profile picture of extruding tire tread including seven measuring values. Another one is a series of thickness and width values. When the scanning speed thickness range is thickness < +/- 0.1mm.

  20. Ambulatory blood pressure monitoring-derived short-term blood pressure variability is increased in Cushing's syndrome.

    Science.gov (United States)

    Rebellato, Andrea; Grillo, Andrea; Dassie, Francesca; Sonino, Nicoletta; Maffei, Pietro; Martini, Chiara; Paoletta, Agostino; Fabris, Bruno; Carretta, Renzo; Fallo, Francesco

    2014-11-01

    Cushing's syndrome is associated with high cardiovascular morbility and mortality. Blood pressure (BP) variability within a 24-h period is increasingly recognized as an independent predictor of cardiovascular risk. The aim of our study was to investigate the short-term BP variability indices in Cushing's syndrome. Twenty-five patients with Cushing's syndrome (mean age 49 ± 13 years, 4 males; 21 Cushing's disease and 4 adrenal adenoma patients) underwent 24-h ambulatory BP monitoring (ABPM) and evaluation of cardiovascular risk factors. Cushing patients were divided into 8 normotensive (NOR-CUSH) and 17 hypertensive (HYP-CUSH) patients and were compared with 20 normotensive (NOR-CTR) and 20 hypertensive (HYP-CTR) age-, sex-, and BMI-matched control subjects. Short-term BP variability was derived from ABPM and calculated as the following: (1) standard deviation (SD) of 24-h, daytime, and nighttime BP; (2) 24-h weighted SD of BP; and (3) average real variability (ARV), i.e., the average of the absolute differences between consecutive BP measurements over 24 h. In comparison with controls, patients with Cushing's syndrome, either normotensive or hypertensive, had higher 24-h and daytime SD of BP, as well as higher 24-h weighted SD and ARV of BP (P = 0.03 to P CUSH or between HYP-CTR and HYP-CUSH subgroups. ABPM-derived short-term BP variability is increased in Cushing's syndrome, independent of BP elevation. It may represent an additional cardiovascular risk factor in this disease. The role of excess cortisol in BP variability has to be further clarified.

  1. Comparison of 44-hour and fixed 24-hour ambulatory blood pressure monitoring in dialysis patients.

    Science.gov (United States)

    Liu, Wenjin; Ye, Hong; Tang, Bing; Sun, Zhiping; Wen, Ping; Wu, Wenhui; Bian, Xueqing; Shen, Xia; Yang, Junwei

    2014-01-01

    The two most commonly used strategies to evaluate dialysis patients' blood pressure (BP) level are 44-hour and 24-hour ambulatory blood pressure monitoring (ABPM). The objective of this study was to find an appropriate 24-hour period that correlated well with the 44-hour BP level and determine the differences between these strategies. In a group of 51 dialysis patients, the authors performed 44-hour ABPM and extracted data for a fixed 24-hour ABPM. The fixed 24-hour ABPM started at 6 am on the nondialysis day. A strong correlation was found between all parameters of 44-hour and the fixed 24-hour ABPM, with paired sample t test showing only small magnitude changes in a few parameters. Both 24-hour ABPM and 44-hour ABPM were superior to clinic BP in predicting left ventricular mass index (LVMI) by multiple regression analysis. It was found that 44-hour ambulatory arterial stiffness index (AASI), but not 24-hour AASI, had a positive association with LVMI (r=0.328, P=.021). However, after adjustment for 44-hour systolic blood pressure, this association disappeared. Fixed 24-hour ABPM is a good surrogate of 44-hour ABPM to some extent, while 44-hour ABPM can provide more accurate and detailed information. ©2013 Wiley Periodicals, Inc.

  2. A wireless intraocular pressure monitoring device with a solder-filled microchannel antenna

    International Nuclear Information System (INIS)

    Varel, Çağdaş; Shih, Yi-Chun; Otis, Brian P; Böhringer, Karl F; Shen, Tueng S

    2014-01-01

    This paper presents the prototype of an intraocular pressure sensor as a major step toward building a device that can be permanently implanted during cataract surgery. The implantation will proceed through an incision of 2–3 mm using an injector, during which the complete device must be folded into a cross-section of 2 mm × 1 mm. The device uses radio frequency (RF) for wireless power and data transfer. The prototype includes an antenna, an RF chip and a pressure sensor assembled on a printed circuit board with several circuit components used for testing and calibration. The antenna is fabricated and integrated with the circuit using a fabrication method employing solder-filled microchannels embedded in an elastomer. The monitoring device is powered at 2.716 GHz from a distance of 1–2 cm. The prototype has undergone electrical and mechanical tests for antenna and sensor performance. The flexible antenna can withstand a stress of 33.4 kPa without any electrical disconnection. It did not show a significant increase in electrical resistance after 50 bending cycles with a maximum applied stress of 116 kPa. Transmitted pressure data shows an averaged sensitivity of 16.66 Hz (mm-Hg) –1 . (paper)

  3. Micro-controller based air pressure monitoring instrumentation system using optical fibers as sensor

    Science.gov (United States)

    Hazarika, D.; Pegu, D. S.

    2013-03-01

    This paper describes a micro-controller based instrumentation system to monitor air pressure using optical fiber sensors. The principle of macrobending is used to develop the sensor system. The instrumentation system consists of a laser source, a beam splitter, two multi mode optical fibers, two Light Dependent Resistance (LDR) based timer circuits and a AT89S8252 micro-controller. The beam splitter is used to divide the laser beam into two parts and then these two beams are launched into two multi mode fibers. One of the multi mode fibers is used as the sensor fiber and the other one is used as the reference fiber. The use of the reference fiber is to eliminate the environmental effects while measuring the air pressure magnitude. The laser beams from the sensor and reference fibers are applied to two identical LDR based timer circuits. The LDR based timer circuits are interfaced to a micro-controller through its counter pins. The micro-controller samples the frequencies of the timer circuits using its counter-0 and counter-1 and the counter values are then processed to provide the measure of air pressure magnitude.

  4. Multipoint Pressure and Temperature Sensing Fiber Optic Cable for Monitoring CO2 Sequestration

    Energy Technology Data Exchange (ETDEWEB)

    Challener, William [General Electric Company, Niskayuna, NY (United States)

    2015-02-10

    This report describes the work completed on contract DE-FE0010116. The goal of this two year project was to develop and demonstrate in the laboratory a highly accurate multi-point pressure measurement fiber optic cable based on MEMS pressure sensors suitable for downhole deployment in a CO2 sequestration well. The sensor interrogator was also to be demonstrated in a remote monitoring system and environmental testing was to be completed to indicate its downhole survivability over a lengthy period of time (e.g., 20 years). An interrogator system based on a pulsed laser excitation was shown to be capable of multiple (potentially 100+) simultaneous sensor measurements. Two sensors packages were completed and spliced in a cable onto the same fiber and measured. One sensor package was subsequently measured at high temperatures and pressures in supercritical CO2, while the other package was measured prior and after being subjected to high torque stresses to mimic downhole deployment. The environmental and stress tests indicated areas in which the package design should be further improved.

  5. [Ambulatory blood pressure monitoring is a useful tool for all patients].

    Science.gov (United States)

    de la Sierra, A

    Clinical blood pressure measurement (BP) is an occasional and imperfect way of estimating this biological variable. Ambulatory blood pressure monitoring (ABPM) is by far the best clinical tool for measuring an individual's blood pressure. Mean values over 24h, through the daytime and at night all make it more possible to predict organic damage and the future development of the disorder. ABPM enables the detection of white-coat hypertension and masked hypertension in both the diagnosis and follow-up of treated patients. Although some of the advantages of ABPM can be reproduced by more automated measurement without the presence of an observer in the clinic or self-measurement at home, there are some other elements of great interest that are unique to ABPM, such as seeing what happens to a patient's BP at night, the night time dipping pattern and short-term variability, all of which relate equally to the patient's prognosis. There is no scientific or clinical justification for denying these advantages, and ABPM should form part of the evaluation and follow-up of practically all hypertensive patients. Rather than continuing unhelpful discussions as to its availability and acceptability, we should concentrate our efforts on ensuring its universal availability and clearly explaining its advantages to both doctors and patients. Copyright © 2016 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Validation of Omron HBP-1300 professional blood pressure monitor based on auscultation in children and adults.

    Science.gov (United States)

    Meng, Linghui; Zhao, Di; Pan, Yan; Ding, Wenqing; Wei, Qing; Li, Hua; Gao, Pingjin; Mi, Jie

    2016-01-13

    BACKGROUnD: To determine whether the professional Omron HBP-1300 blood pressure (BP) monitor meets American Association for the Advancement of Medical Instrumentation (AAMI) accuracy standards in Chinese children and adults. According to the AAMI protocol, simultaneous auscultatory measurements by two observers using a mercury manometer were obtained in participants using the Omron HBP-1300. Triple measurements were obtained after a minimum 5-min rest with a 1-min interval between adjacent measurements. A total of 85 participants submitted to 255 doctor-measured BP and 255 successful professional monitor readings. The initial auscultation systolic BP was 160 mmHg in seven participants (8.2%). All of the simultaneous measurements agreed to within ± 10 mmHg, while 95% agreed to within ± 4 mmHg for both systolic and diastolic BP, and the consistency between two observers was satisfactory. The difference between the devices was -1.3 ± 3.6 mmHg for systolic BP and 0.7 ± 3.8 mmHg for diastolic BP and by AAMI method 1, which met this guideline. The average difference between two devices by AAMI method 2 was 1.4 ± 3.2 mmHg for systolic BP and 1.0 ± 3.9 mmHg for diastolic BP, which met this guideline. The professional BP monitor Omron HBP-1300 is desirable for measuring the BP for Chinese children and adults.

  7. Sleep Monitoring Based on a Tri-Axial Accelerometer and a Pressure Sensor

    Directory of Open Access Journals (Sweden)

    Yunyoung Nam

    2016-05-01

    Full Text Available Sleep disorders are a common affliction for many people even though sleep is one of the most important factors in maintaining good physiological and emotional health. Numerous researchers have proposed various approaches to monitor sleep, such as polysomnography and actigraphy. However, such approaches are costly and often require overnight treatment in clinics. With this in mind, the research presented here has emerged from the question: “Can data be easily collected and analyzed without causing discomfort to patients?” Therefore, the aim of this study is to provide a novel monitoring system for quantifying sleep quality. The data acquisition system is equipped with multimodal sensors, including a three-axis accelerometer and a pressure sensor. To identify sleep quality based on measured data, a novel algorithm, which uses numerous physiological parameters, was proposed. Such parameters include non-REM sleep time, the number of apneic episodes, and sleep durations for dominant poses. To assess the effectiveness of the proposed system, three participants were enrolled in this experimental study for a duration of 20 days. From the experimental results, it can be seen that the proposed monitoring system is effective for quantifying sleep quality.

  8. Limitations and challenges of EIT-based monitoring of stroke volume and pulmonary artery pressure.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Lemay, Mathieu; Bertschi, Mattia; Adler, Andy; Thiran, Jean-Philippe; Solà, Josep

    2018-01-30

    Electrical impedance tomography (EIT) shows potential for radiation-free and noninvasive hemodynamic monitoring. However, many factors degrade the accuracy and repeatability of these measurements. Our goal is to estimate the impact of this variability on the EIT-based monitoring of two important central hemodynamic parameters: stroke volume (SV) and pulmonary artery pressure (PAP). We performed simulations on a 4D ([Formula: see text]) bioimpedance model of a human volunteer to study the influence of four potential confounding factors (electrode belt displacement, electrode detachment, changes in hematocrit and lung air volume) on the performance of EIT-based SV and PAP estimation. Results were used to estimate how these factors affect the EIT measures of either absolute values or relative changes (i.e. trending). Our findings reveal that the absolute measurement of SV via EIT is very sensitive to electrode belt displacements and lung conductivity changes. Nonetheless, the trending ability of SV EIT might be a promising alternative. The timing-based measurement of PAP is more robust to lung conductivity changes but sensitive to longitudinal belt displacements at severe hypertensive levels and to rotational displacements (independent of the PAP level). We identify and quantify the challenges of EIT-based SV and PAP monitoring. Absolute SV via EIT is challenging, but trending is feasible, while both the absolute and trending of PAP via EIT are mostly impaired by belt displacements.

  9. Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2013-08-01

    The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.

  10. Non-constrained monitoring of systolic blood pressure on a weighing scale

    International Nuclear Information System (INIS)

    Shin, Jae Hyuk; Lee, Kang Moo; Park, Kwang Suk

    2009-01-01

    In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured using three different methods: on the chest using Ag/AgCl electrodes, on the hands using dry electrodes and on the feet also using dry electrodes. For a BP correlated parameter, a time interval parameter, which was defined as the time difference between the ECG R-peak and BCG J-peak, was employed for evaluating and estimating beat-to-beat BP. Under a BP varying experiment with a Valsalva manoeuvre, the R–J intervals were extracted at every beat cycle and a systolic blood pressure (SBP) estimation equation was established using linear regression analysis for each subject. In the case of feet delivered ECG (F-ECG), an ensemble average technique synchronized at the BCG J-peak point was applied to extract the ECG signal from the feet. The performance of the proposed method was evaluated using Finapres, a non-invasive blood pressure measurement system, as a reference BP signal, and a scatter plot was used to find the regression line between the reference values and estimated BPs. A moving-window averaging technique was applied to remove the high-frequency noise in the R–J intervals and was applied to enhance the accuracy of the SBP estimation. For all individuals, the estimated SBP was similar to the measured SBP with a reliable correlation, which makes the proposed method suitable for use in a home healthcare system to monitor blood pressure on a weighing scale at the same time as measuring weight

  11. Unconstrained pulse pressure monitoring for health management using hetero-core fiber optic sensor.

    Science.gov (United States)

    Nishiyama, Michiko; Sonobe, Masako; Watanabe, Kazuhiro

    2016-09-01

    In this paper, we present a pulse pressure waveform sensor that does not constrain a wearer's daily activity; the sensor uses hetero-core fiber optics. Hetero-core fiber sensors have been found to be sensitive to moderate bending. To detect minute pulse pressure changes from the radial artery at the wrist, we devised a fiber sensor arrangement using three-point bending supports. We analyzed and evaluated the measurement validity using wavelet transformation, which is well-suited for biological signal processing. It was confirmed that the detected pulse waveform had a fundamental mode frequency of around 1.25 Hz over the time-varying waveform. A band-pass filter with a range of frequencies from 0.85 to 1.7 Hz was used to pick up the fundamental mode. In addition, a high-pass filter with 0.85 Hz frequency eliminated arm motion artifacts; consequently, we achieved high signal-to-noise ratio. For unrestricted daily health management, it is desirable that pulse pressure monitoring can be achieved by simply placing a device on the hand without the sensor being noticed. Two types of arrangements were developed and demonstrated in which the pulse sensors were either embedded in a base, such as an armrest, or in a wearable device. A wearable device without cuff pressure using a sensitivity-enhanced fiber sensor was successfully achieved with a sensitivity of 0.07-0.3 dB with a noise floor lower than 0.01 dB for multiple subjects.

  12. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  13. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    Science.gov (United States)

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  14. Continuous monitoring of intracranial pressure after endoscopic third ventriculostomy in the management of CSF shunt failure.

    Science.gov (United States)

    Elgamal, E A

    2010-04-01

    The effectiveness of continuous intracranial pressure (ICP) monitoring in the adaptation period, after endoscopic third ventriculostomy (ETV), and removal of the failed shunt in the management of CSF shunt failure is assessed. Nine patients with active hydrocephalus presenting with CSF shunt obstruction or infection were managed by ETV, removal of the shunt and insertion of an external ventricular drain (EVD) containing an ICP sensor for the purpose of postoperative monitoring of the ICP, and intermittent drainage of CSF. Patient ages ranged from 8 months to 24 years, and six of them were females. Hydrocephalus was obstructive in seven patients, and multiloculated in two. Six patients had an ventriculoperitoneal shunt (VPS), one with a bilateral VPS, one patient had a ventriculoatrial shunt, and one had a VPS and cystoperitoneal shunt (CPS). Shunt failure was caused by obstruction in six patients and infection in three. The post-operative ICP monitoring period ranged from 1-7 days. Intracranial hypertension was persistent in the first day after ETV in 3 patients, and up to 110 mL of CSF were drained to improve its symptoms. ETV was successful in six patients and 3 had permanent VPS. Post-operative continuous ICP monitoring and EVD insertion were very useful in the treatment of CSF shunt failure with ETV. This procedure allowed intermittent CSF drainage, relieving symptoms of elevated ICP, and provided accurate assessment of the success of the ETV and patency of the stoma in the early postoperative days by CT ventriculography and can also be used to install antibiotics in cases of infection.

  15. Recovery and disposal of discarded tires in the Taiwan area.

    Science.gov (United States)

    Hwang, J S; Roam, G D

    1994-12-01

    Urbanization and industrialization has resulted in a vast amount of artificial water containers in Taiwan, especially discarded automobile tires. 3.5 million automobile tires and several million motorcycle tires are discarded annually. The discarded tires contaminate the environment and also become a substantial number of breeding sites for the dengue vector mosquitoes. In order to establish a sound system for the recovery and disposal of discarded tires and to control dengue fever through source reduction, it has been emphasized that users must pay for their waste. It is necessary to recover and properly dispose of these discarded tired. The commercial firms which sell or manufacture tires are therefore advised to cooperate with the Environmental Protection Administration of the Executive Yuan, R.O.C. and follow the "Regulations of Recovery and Disposal of Discarded Tires". They are requested to establish foundations for the recovery of discarded tires. Those who are willing to join should prepay a deposit or related charge by the size of tire, which is imported or locally manufactured. The foundation utilizes the deposits for the recovery and disposal of discarded tires. From 1991 to 1993 the commercial tire firms had already achieved the 80% recovery rates declared by the authorities concerned. Some of the tires, after having been recovered, were recycled in the original form and the rest were cut into small pieces for recycling after physical treatment. It should be mentioned that the Department of Environmental Protection of Kaohsiung City has collected 80 thousand discarded automobile tires to be used as ocean jetty.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Demonstration of the waste tire pyrolysis process on pilot scale in a continuous auger reactor.

    Science.gov (United States)

    Martínez, Juan Daniel; Murillo, Ramón; García, Tomás; Veses, Alberto

    2013-10-15

    This work shows the technical feasibility for valorizing waste tires by pyrolysis using a pilot scale facility with a nominal capacity of 150 kWth. A continuous auger reactor was operated to perform thirteen independent experiments that conducted to the processing of more than 500 kg of shredded waste tires in 100 h of operation. The reaction temperature was 550°C and the pressure was 1 bar in all the runs. Under these conditions, yields to solid, liquid and gas were 40.5 ± 0.3, 42.6 ± 0.1 and 16.9 ± 0.3 wt.% respectively. Ultimate and proximate analyses as well as heating value analysis were conducted for both the solid and liquid fraction. pH, water content, total acid number (TAN), viscosity and density were also assessed for the liquid and compared to the specifications of marine fuels (standard ISO 8217). Gas chromatography was used to calculate the composition of the gaseous fraction. It was observed that all these properties remained practically invariable along the experiments without any significant technical problem. In addition, the reaction enthalpy necessary to perform the waste tire pyrolysis process (907.1 ± 40.0 kJ/kg) was determined from the combustion and formation enthalpies of waste tire and conversion products. Finally, a mass balance closure was performed showing an excellent reliability of the data obtained from the experimental campaign. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Investigation of the recycling of tires to elastomeric requirements by techniques of thermal compression

    Science.gov (United States)

    Nadal Gisbert, Antonio V.

    In this work is investigated the recycling of tires to elastomeric requirements by thermal compression. The production of recycled products is carried out starting from the powder, of elastomeric nature, coming from the grinding of used tires denominated GTR (Ground Tire Rubber) of different grain size, although the fundamental objective is the recycling of powder of 0,2mm grain size. The process of forming used for obtaining the recycled product is thermal compression, due to its simplicity and low cost. The composition of the powder has been analyzed and also the influence, on the elastomeric characteristics of the recycled product, of different parameters: Grain size, compact pressure, temperature, time, thickness of the recycled product and combination of sizes. At last we give an hypothesis that justifies the mechanism that gives cohesion to the powder GTR and allows their recycling. We also have carried out an analysis of the investigation lines, at the present, on the recycling of tires in general and an economic study of the viability of the recycled product in front of present products in the market, agglomerated with polyurethane, that have their application in using it in different types of floors.

  18. Development of instrumentation systems for severe accidents. 4. New accident tolerant in-containment pressure transducer for containment pressure monitoring system

    International Nuclear Information System (INIS)

    Oba, Masato; Teruya, Kuniyuki; Yoshitsugu, Makoto; Ikeuchi, Takeshi

    2015-01-01

    The accident at Tokyo Electric Power Company's Fukushima Dai-ichi Nuclear Power Plant (TF-1 accident) caused severe situations and resulted in a difficulty in measuring important parameters for monitoring plant conditions. Therefore, we have studied the TF-1 accident to select the important parameters that should be monitored at the severe accident and are developing the Severe Accident Instrumentations and Monitoring Systems that could measure the parameters in severe accident conditions. Mitsubishi Heavy Industries, LTD (MHI) developed a new accident tolerant containment pressure monitoring system and demonstrated that the monitoring system could endure extremely harsh environmental conditions that envelop severe accident environmental conditions inside a containment such as maximum operating temperature of up to 300degC and total integrated dose (TID) of 1 MGy gamma. The new containment pressure monitoring system comprises of a strain gage type pressure transducer and a mineral insulated (MI) cable with ceramic connectors, which are located in the containment, and a strain measuring amplifier located outside the containment. Less thermal and radiation degradation is achieved because of minimizing use of organic materials for in-containment equipment such as the transducer and connectors. Several tests were performed to demonstrate the performance and capability of the in-containment equipment under severe accident environmental conditions and the major steps in this testing were run in the following test sequences: (1) the baseline functional tests (e.g., repeatability, non-linearity, hysteresis, and so on) under normal conditions, (2) accident radiation testing, (3) seismic testing, and (4) steam/temperature test exposed to simulated severe accident environmental conditions. The test results demonstrate that the new pressure transducer can endure the simulated severe accident conditions. (author)

  19. Ambulatory Blood Pressure Monitoring in Children and Adolescents: a Review of Recent Literature and New Guidelines.

    Science.gov (United States)

    Macumber, Ian

    2017-10-25

    This is a review of ambulatory blood pressure monitoring (ABPM) use in pediatrics, focusing on research published in the last 3 to 4 years. Recent data has shown that ABPM is more strongly associated with end-organ damage than casual BP, and that obesity and secondary causes of hypertension are strongly associated with nocturnal hypertension. There is evidence that ABPM is useful in management of a larger variety of diagnoses than previously thought. New guidelines from the American Academy of Pediatrics recognize the importance of ABPM in the management of pediatric hypertension. ABPM has an important and growing role in the diagnosis and management of hypertension in children and adolescents. Future efforts should include developing more generalizable normative data and investigating associations between pediatric ABPM results and adult outcomes.

  20. Evaporation monitoring and composition control of alloy systems with widely differing vapor pressures

    International Nuclear Information System (INIS)

    Anklam, T.M.; Berzins, L.V.; Braun, D.G.; Haynam, C.; McClelland, M.A.; Meier, T.

    1994-10-01

    Lawrence Livermore National Laboratory is developing sensors and controls to improve and extend electron beam materials processing technology to alloy systems with constituents of widely varying vapor pressure. The approach under development involves using tunable lasers to measure the density and composition of the vapor plume. A laser based vaporizer control system for vaporization of a uranium-iron alloy has been previously demonstrated in multi-hundred hour, high rate vaporization experiments at LLNL. This paper reviews the design and performance of the uranium vaporization sensor and control system and discusses the extension of the technology to monitoring of uranium vaporization. Data is presented from an experiment in which titanium wire was fed into a molten niobium pool. Laser data is compared to deposited film composition and film cross sections. Finally, the potential for using this technique for composition control in melting applications is discussed

  1. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation methods (least error squares and filtering)

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the ''primary coolant circuit inventory monitoring'' of a pressurized water reactor. A reference model is developed in view of an automatic system ensuring detection and diagnostic in real time. The methods used for the present application are statistical tests and a method related to pattern recognition. The estimation of failures detected, difficult owing to the non-linearity of the problem, is treated by the least error squares method of the predictor or corrector type, and by filtering. It is in this frame that a new optimized method with superlinear convergence is developed, and that a segmented linearization of the model is introduced, in view of a multiple filtering [fr

  2. [Correlation between indices of 24-h monitoring of blood pressure and disturbed venous cerebral outflow in hypertensive patients].

    Science.gov (United States)

    Afanas'eva, N L; Mordovin, V F; Semke, G V; Luk'ianenok, P I

    2008-01-01

    To study relations between disturbances of cerebral venous circulation and parameters of 24-h blood pressure monitoring in hypertensive patients. A total of 72 patients aged 28 to 60 years with essential hypertension of stage II have undergone 24-h blood pressure monitoring and MR-venography of the brachiocephalic veins on a low-field MR-tomograph using 2D TOF angiography. Symptoms of disturbed cerebral venous circulation were found in 60% patients. Major venous collectors were asymmetric in 79.2% patients, 40.3% had marked asymmetry, 14% had severe asymmetry. Disturbances of venous outflow significantly more frequently occurred in non-dippers and night-peakers as well as in high variability of blood pressure. Patients with marked asymmetry of venous collectors had elevated nocturnal systolic and diastolic blood pressure, high load indices of nocturnal systolic and diastolic pressure, a low degree of nocturnal fall of blood pressure. Disturbance of venous cerebral outflow in hypertensive patients is closely related with alterations of a circadian profile of blood pressure: circadian index of blood pressure, variability of blood pressure.

  3. BION-M 1: First continuous blood pressure monitoring in mice during a 30-day spaceflight

    Science.gov (United States)

    Andreev-Andrievskiy, Alexander; Popova, Anfisa; Lloret, Jean-Christophe; Aubry, Patrick; Borovik, Anatoliy; Tsvirkun, Daria; Vinogradova, Olga; Ilyin, Eugeniy; Gauquelin-Koch, Guillemette; Gharib, Claude; Custaud, Marc-Antoine

    2017-05-01

    Animals are an essential component of space exploration and have been used to demonstrate that weightlessness does not disrupt essential physiological functions. They can also contribute to space research as models of weightlessness-induced changes in humans. Animal research was an integral component of the 30-day automated Russian biosatellite Bion-M 1 space mission. The aim of the hemodynamic experiment was to estimate cardiovascular function in mice, a species roughly 3000 times smaller than humans, during prolonged spaceflight and post-flight recovery, particularly, to investigate if mice display signs of cardiovascular deconditioning. For the first time, heart rate (HR) and blood pressure (BP) were continuously monitored using implantable telemetry during spaceflight and recovery. Decreased HR and unchanged BP were observed during launch, whereas both HR and BP dropped dramatically during descent. During spaceflight, BP did not change from pre-flight values. However, HR increased, particularly during periods of activity. HR remained elevated after spaceflight and was accompanied by increased levels of exercise-induced tachycardia. Loss of three of the five mice during the flight as a result of the hardware malfunction (unrelated to the telemetry system) and thus the limited sample number constitute the major limitation of the study. For the first time BP and HR were continuously monitored in mice during the 30-day spaceflight and 7-days of post-flight recovery. Cardiovascular deconditioning in these tiny quadruped mammals was reminiscent of that in humans. Therefore, the loss of hydrostatic pressure in space, which is thought to be the initiating event for human cardiovascular adaptation in microgravity, might be of less importance than other physiological mechanisms. Further experiments with larger number of mice are needed to confirm these findings.

  4. Rates, Amounts, and Determinants of Ambulatory Blood Pressure Monitoring Claim Reimbursements Among Medicare Beneficiaries

    Science.gov (United States)

    Kent, Shia T.; Shimbo, Daichi; Huang, Lei; Diaz, Keith M.; Viera, Anthony J.; Kilgore, Meredith; Oparil, Suzanne; Muntner, Paul

    2014-01-01

    Ambulatory blood pressure monitoring (ABPM) can be used to identify white coat hypertension and guide hypertensive treatment. We determined the percentage of ABPM claims submitted between 2007–2010 that were reimbursed. Among 1,970 Medicare beneficiaries with submitted claims, ABPM was reimbursed for 93.8% of claims that had an ICD-9 diagnosis code of 796.2 (“elevated blood pressure reading without diagnosis of hypertension”) versus 28.5% of claims without this code. Among claims without an ICD-9 diagnosis code of 796.2 listed, those for the component (e.g., recording, scanning analysis, physician review, reporting) versus full ABPM procedures and performed by institutional versus non-institutional providers were each more than two times as likely to be successfully reimbursed. Of the claims reimbursed, the median payment was $52.01 (25–75th percentiles: $32.95–$64.98). In conclusion, educating providers on the ABPM claims reimbursement process and evaluation of Medicare reimbursement may increase the appropriate use of ABPM and improve patient care. PMID:25492833

  5. The Use of Ambulatory Blood Pressure Monitoring As Standard of Care in Pediatrics

    Science.gov (United States)

    Peterson, Caitlin G.; Miyashita, Yosuke

    2017-01-01

    Hypertension (HTN) is a significant global health problem, responsible for 7.5 million deaths each year worldwide. The prevalence of HTN is increasing in the pediatric population likely attributed to the increase in childhood obesity. Recent work has also shown that blood pressure (BP) tends to track from childhood to adulthood including BP-related target organ damage. In the last 25–30 years, pediatric use of ambulatory blood pressure monitoring (ABPM) has been expanding mainly in the setting of initial elevated BP measurement evaluation, HTN therapy efficacy follow-up, and renal disease. However, there are many clinical areas where ABPM could potentially be used but is currently underutilized. This review summarizes the current knowledge and the uses of pediatric ABPM and explores clinical areas where it can be very useful both to detect HTN and its longitudinal follow-up. And thus, ABPM could serve as a critical tool to potentially prevent early cardiovascular mortality and morbidity in wide variety of populations. With solid data to support ABPM’s superiority over clinic BP measurements and these clinical areas for its expansion, ABPM should now be part of standard of care in BP evaluation and management in pediatrics. PMID:28713799

  6. Efficacy of 24-Hour Blood Pressure Monitoring in Evaluating Response to Percutaneous Transluminal Renal Angioplasty.

    Science.gov (United States)

    Jujo, Kentaro; Saito, Katsumi; Ishida, Issei; Furuki, Yuho; Ouchi, Taisuke; Kim, Ahsung; Suzuki, Yuki; Sekiguchi, Haruki; Yamaguchi, Junichi; Ogawa, Hiroshi; Hagiwara, Nobuhisa

    2016-08-25

    Percutaneous transluminal renal angioplasty (PTRA) improves patency in atherosclerotic renal artery stenosis (ARAS), but improvement in clinic blood pressure (BP) is seen in only 20-40% of patients who undergo PTRA. This study investigated the effects of PTRA on BP lowering, assessed on 24-h ambulatory BP monitoring (ABPM), and identified preoperative features predictive of satisfactory BP improvement after PTRA. Of 1,753 consecutive patients undergoing coronary angiography, 31 patients with angiographically significant ARAS and translesional pressure gradient (TLPG) >20 mmHg underwent PTRA. ABPM was performed before, at 1 month and at 1 year after PTRA; patients with average systolic ABPM-BP decrease >10 mmHg at 1 month from baseline were categorized as responders. There was no obvious relationship between clinic BP and ABPM-BP at baseline. ABPM-BP was significantly higher in responders at baseline (SBP: 148 vs. 126 mmHg, PABPM-BP achieved a larger decrease in ABPM-BP, but the severity of stenosis reflected by TLPG; renal duplex findings; and neurohumoral parameters other than baseline renal function, did not differ between the groups. Clinic BP does not represent daily hemodynamic status, whereas high ABPM-BP is a potent predictor of satisfactory BP response to PTRA. (Circ J 2016; 80: 1922-1930).

  7. An Implantable Cardiovascular Pressure Monitoring System with On-Chip Antenna and RF Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Yu-Chun Liu

    2015-08-01

    Full Text Available An implantable wireless system with on-chip antenna for cardiovascular pressure monitor is studied. The implantable device is operated in a batteryless manner, powered by an external radio frequency (RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The integrated electronic system, consisting of a capacitance-to-voltage converter, an adaptive RF powering system, an RF transmitter and digital control circuitry, is simulated using a TSMC 0.18 μm CMOS technology. The implanted RF transmitter circuit is combined with a low power voltage-controlled oscillator resonating at 5.8 GHz and a power amplifier. For the design, the simulation model is setup using ADS and HFSS software. The dimension of the antenna is 1 × 0.6 × 4.8 mm3 with a 1 × 0.6 mm2 on-chip circuit which is small enough to place in human carotid artery.

  8. Upcoming methods and specifications of continuous intraocular pressure monitoring systems for glaucoma

    Directory of Open Access Journals (Sweden)

    Amir Molaei

    2018-01-01

    Full Text Available Glaucoma is the leading cause of irreversible blindness and vision loss in the world. Although intraocular pressure (IOP is no longer considered the only risk factor for glaucoma, it is still the most important one. In most cases, high IOP is secondary to trabecular meshwork dysfunction. High IOP leads to compaction of the lamina cribrosa and subsequent damage to retinal ganglion cell axons. Damage to the optic nerve head is evident on funduscopy as posterior bowing of the lamina cribrosa and increased cupping. Currently, the only documented method to slow or halt the progression of this disease is to decrease the IOP; hence, accurate IOP measurement is crucial not only for diagnosis, but also for the management. Due to the dynamic nature and fluctuation of the IOP, a single clinical measurement is not a reliable indicator of diurnal IOP; it requires 24-hour monitoring methods. Technological advances in microelectromechanical systems and microfluidics provide a promising solution for the effective measurement of IOP. This paper provides a broad overview of the upcoming technologies to be used for continuous IOP monitoring.

  9. Inverse method for stress monitoring in pressure components of steam generators

    International Nuclear Information System (INIS)

    Duda, P.

    2003-01-01

    The purpose of this work is to formulate a space marching method, which can be used to solve inverse multidimensional heat conduction problems. The method is designed to reconstruct the transient temperature distribution in a whole construction element based on measured temperatures taken at selected points inside or on the outer surface of the construction element. Next, the Finite Element Method is used to calculate thermal stresses and stresses caused by other loads such as, for instance, internal pressure. The developed method for solving temperature and total stress distribution will be tested using the measured temperatures generated from a direct solution. Transient temperature and total stress distribution obtained from method presented below will be compared with the values obtained from the direct solution. Finally, the presented method will be applied in order to monitor temperature and stress distribution in an outlet header using the real measured temperature values at seven points on the header's outer surface during the power boiler's shut down operation. The presented method allows to optimize the power block's start-up and shut-down operations, contributes to the reduction of heat loss during these operations and to the extension of power block's life. The fatigue and creep usage factor can be computed in an on-line mode. The presented method herein can be applied to monitoring systems that work in conventional as well as in nuclear power plants. (author)

  10. Thermolysis of scrap tire and rubber in sub/super-critical water.

    Science.gov (United States)

    Li, Qinghai; Li, Fuxin; Meng, Aihong; Tan, Zhongchao; Zhang, Yanguo

    2018-01-01

    The rapid growth of waste tires has become a serious environmental issue. Energy and material recovery is regarded as a promising use for waste tires. Thermolysis of scrap tire (ST), natural rubber (NR), and styrene-butadiene rubber (SBR) was carried out in subcritical and supercritical water using a temperature-pressure independent adjustable batch tubular reactor. As a result, oil yields increased as temperature and pressure increased, and they reached maximum values as the state of water was near the critical point. However, further increases in water temperature and pressure reduced the oil yields. The maximum oil yield of 21.21% was obtained at 420 °C and 18 MPa with a reaction time of 40 min. The relative molecular weights of the chemicals in the oil products were in the range of 70-140 g/mole. The oil produced from ST, NR, and SBR contained similar chemical compounds, but the oil yield of SR was between those of NR and SBR. The oil yield from thermolysis of subcritical or supercritical water should be further improved. The main gaseous products, including CH 4 , C 2 H 2 , C 2 H 4 , C 2 H 6 , and C 3 H 8 , increased with reaction time, temperature, and pressure, whereas the solid residues, including carbon black and impurities, decreased. These results provide useful information to develop a sub/super-critical water thermolysis process for energy and material regeneration from waste tires. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Intrathecal pressure monitoring and cerebrospinal fluid drainage in acute spinal cord injury: a prospective randomized trial.

    Science.gov (United States)

    Kwon, Brian K; Curt, Armin; Belanger, Lise M; Bernardo, Arlene; Chan, Donna; Markez, John A; Gorelik, Stephen; Slobogean, Gerard P; Umedaly, Hamed; Giffin, Mitch; Nikolakis, Michael A; Street, John; Boyd, Michael C; Paquette, Scott; Fisher, Charles G; Dvorak, Marcel F

    2009-03-01

    Ischemia is an important factor in the pathophysiology of secondary damage after traumatic spinal cord injury (SCI) and, in the setting of thoracoabdominal aortic aneurysm repair, can be the primary cause of paralysis. Lowering the intrathecal pressure (ITP) by draining CSF is routinely done in thoracoabdominal aortic aneurysm surgery but has not been evaluated in the setting of acute traumatic SCI. Additionally, while much attention is directed toward maintaining an adequate mean arterial blood pressure (MABP) in the acute postinjury phase, little is known about what is happening to the ITP during this period when spinal cord perfusion pressure (MABP - ITP) is important. The objectives of this study were to: 1) evaluate the safety and feasibility of draining CSF to lower ITP after acute traumatic SCI; 2) evaluate changes in ITP before and after surgical decompression; and 3) measure neurological recovery in relation to the drainage of CSF. Twenty-two patients seen within 48 hours of injury were prospectively randomized to a drainage or no-drainage treatment group. In all cases a lumbar intrathecal catheter was inserted for 72 hours. Acute complications of headache/nausea/vomiting, meningitis, or neurological deterioration were carefully monitored. Acute Spinal Cord Injury motor scores were documented at baseline and at 6 months postinjury. On insertion of the catheter, mean ITP was 13.8 +/- 1.3 mm Hg (+/- SD), and it increased to a mean peak of 21.7 +/- 1.5 mm Hg intraoperatively. The difference between the starting ITP on catheter insertion and the observed peak intrathecal pressure after decompression was, on average, an increase of 7.9 +/- 1.6 mm Hg (p drainage group was 30.6 +/- 2.3 mm Hg, which was significantly higher than the peak intraoperative ITP (p = 0.0098). During the same period, the peak recorded ITP in patients randomized to receive drainage was 28.1 +/- 2.8 mm Hg, which was not statistically higher than the peak intraoperative ITP (p = 0.15). The

  12. Low cost self-made pressure distribution sensors for ergonomic chair: Are they suitable for posture monitoring?

    Science.gov (United States)

    Martinaitis, Arnas; Daunoraviciene, Kristina

    2018-05-18

    Long sitting causes many health problems for people. Healthy sitting monitoring systems, like real-time pressure distribution measuring, is in high demand and many methods of posture recognition were developed. Such systems are usually expensive and hardly available for the regular user. The aim of study is to develop low cost but sensitive enough pressure sensors and posture monitoring system. New self-made pressure sensors have been developed and tested, and prototype of pressure distribution measuring system was designed. Sensors measured at average noise amplitude of a = 56 mV (1.12%), average variation in sequential measurements of the same sensor s = 17 mV (0.34%). Signal variability between sensors averaged at 100 mV (2.0%). Weight to signal dependency graph was measured and hysteresis calculated. Results suggested the use of total sixteen sensors for posture monitoring system with accuracy of sensor sensitivity and repeatability are acceptable for posture monitoring, and it is possible to build low cost pressure distribution measurement system with graphical visualization without expensive equipment or complicated software.

  13. Analysis of 24-Hour Ambulatory Blood Pressure Monitoring Data using Orthonormal Polynomials in the Linear Mixed Model

    OpenAIRE

    Edwards, Lloyd J.; Simpson, Sean L.

    2010-01-01

    The use of 24-hour ambulatory blood pressure monitoring (ABPM) in clinical practice and observational epidemiological studies has grown considerably in the past 25 years. ABPM is a very effective technique for assessing biological, environmental, and drug effects on blood pressure. In order to enhance the effectiveness of ABPM for clinical and observational research studies via analytical and graphical results, developing alternative data analysis approaches are important. The linear mixed mo...

  14. Technical and environmental assessment of the scrap tire vacuum pyrolysis process

    International Nuclear Information System (INIS)

    Roy, C.; Caumia, B. de; Lebrecque, B.; Blanchette, D.; Pakdel, H.; Roy, V.

    1991-01-01

    Tire recycling has become a necessity because of the huge piles of tires which represent a threat to the environment. There is about one worn tire produced per year and per person in the developed countries. The used tires represent a source of energy and valuable chemical products. By thermal decomposition of rubber under reduced pressure, it is possible to recover the useful compounds. A step by step approach has been used, from bench-scale batch systems, to process development and finally pilot plant, to experiment and develop vacuum pyrolysis of used tires. Yields are: 55% oil, 25% carbon black, 9% steel, 5% fiber and 6% gas. The maximum recovery of oil was performed at 415 degree C below 2 kPa abs. The specific gravity of this oil was 0.95, its gross heating value was 43 MJ/kg and total sulfur content about 0.8%. It was rich in limonene, benzol and other petrochemical components. The carbon black favorably compared with the low standard grades and may find an application in low grade rubber goods following further research and development. From an environmental point of view, the quality of the gas emissions was found to be acceptable based on the province of Quebec regulations. The aqueous phase contains toxic substances which will be eliminated after blending and burning it with pyrolysis oils used to heat up the reactor. The heat of pyrolysis for the reactions is low, estimated around 700 kJ/kg. The process has been tested in a 200 kg/h pilot plant, which positively demonstrated the possibility of continuously feeding large chunks of rubber under a vacuo. The process feasibility is promising, with returns on the investment of 31% after three years of operation. 9 refs., 4 figs., 8 tabs

  15. Continuous cuff-less blood pressure monitoring based on the pulse arrival time approach: the impact of posture.

    Science.gov (United States)

    Muehlsteff, J; Aubert, X A; Morren, G

    2008-01-01

    There is an unmet need for cuff-less blood pressure (BP) monitoring especially, in personal healthcare applications. The pulse arrival time (PAT) approach might offer a suitable solution to enable comfortable BP monitoring even at beat-level. However, the methodology is based on hemodynamic surrogate measures, which are sensitive to patient activities such as posture changes, not necessarily related to blood pressure variations. In this paper, we analyze the impact of posture on the PAT measure and related hemodynamic parameters such as the pre-ejection period in well-defined procedures. Additionally, the PAT of a monitored subject is investigated in an unsupervised scenario illustrating the complexity of such a measurement. Our results show the failure of blood pressure inference based on simple calibration strategies using the PAT measure only. We discuss opportunities to compensate for the observed effects towards the realization of wearable cuff-less blood pressure monitoring. These findings emphasize the importance of accessing context information in personal healthcare applications, where vital sign monitoring is typically unsupervised.

  16. Relationships among the contact patch length and width, the tire deflection and the rolling resistance of a free-running wheel in a soil bin facility

    Energy Technology Data Exchange (ETDEWEB)

    Tomaraee, P.; Mardani, A.; Mohebbi, A.; Taghavifar, H.

    2015-07-01

    Qualitative and quantitative analysis of contact patch length-rolling resistance, contact patch width-rolling resistance and tire deflection-rolling resistance at different wheel load and inflation pressure levels is presented. The experiments were planned in a randomized block design and were conducted in the controlled conditions provided by a soil bin environment utilizing a well-equipped single wheel-tester of Urmia University, Iran. The image processing technique was used for determination of the contact patch length and contact patch width. Analysis of covariance was used to evaluate the correlations. The highest values of contact length and width and tire deflection occurred at the highest wheel load and lowest tire inflation pressure. Contact patch width is a polynomial (order 2) function of wheel load while there is a linear relationship between tire contact length and wheel load as well as between tire deflection and wheel load. Correlations were developed for the evaluation of contact patch length-rolling resistance, contact patch width-rolling resistance and tire deflection-rolling resistance. It is concluded that the variables studied have a significant effect on rolling resistance. (Author)

  17. Automobile Tire Assessment: A Multi-Criteria Approach

    Directory of Open Access Journals (Sweden)

    Ateekh-Ur-Rehman

    2017-02-01

    Full Text Available In response to the present dynamic market, automobile manufacturing industries are constantly evaluating and improving their manufacturing strategies to stay competitive. It is also evident that they evaluate those strategies considering multiple criteria. In one such case, an automobile project manager has to ensure that the selected tire (among the available alternatives complies with the prospective automobile’s performance. This paper presents an approach for the assessment of alternative automobile tires taking into account multiple criteria, such as tire sustainability, tire road performance, environmental issues, tire purchase cost and tire road grip. The presented approach is quite helpful to any decision maker who is interested not only in ranking alternatives but also in establishing the superiority of an alternative over others. The approach also helps to specify the position of each alternative with respect to ideal solution. A case illustration is used to demonstrate an application of the approach.

  18. A new use for old tires

    International Nuclear Information System (INIS)

    Louie, Jacqueline

    2011-01-01

    This paper presents the Dreamcatcher oil spill technology developed by National Oilwell Varco Canada. The products and services using this technology can save recycled tires from the landfill, which makes the planet a greener place. The products and services in question are those used for remediating and preventing soil and water contamination. The technological products use rubber tires and degrade the rubber into two compounds. The first is the smart crumb, which is a fine rubber crumb used for oil spill adsorption on land. The second is the aqua fiber, a fiber/rubber compound that is used to adsorb oil spills on water. Both are oleophilic (oil attracting) and hydrophobic (water repelling). This allows them to filter hydrocarbons quickly from water. After the smart crumb adsorbs hydrocarbons, it is then used to make asphalt products and the aqua fiber is used to replace sand and gravel in residential and commercial concrete and asphalt respectively.

  19. A new use for old tires

    Energy Technology Data Exchange (ETDEWEB)

    Louie, Jacqueline

    2011-12-15

    This paper presents the Dreamcatcher oil spill technology developed by National Oilwell Varco Canada. The products and services using this technology can save recycled tires from the landfill, which makes the planet a greener place. The products and services in question are those used for remediating and preventing soil and water contamination. The technological products use rubber tires and degrade the rubber into two compounds. The first is the smart crumb, which is a fine rubber crumb used for oil spill adsorption on land. The second is the aqua fiber, a fiber/rubber compound that is used to adsorb oil spills on water. Both are oleophilic (oil attracting) and hydrophobic (water repelling). This allows them to filter hydrocarbons quickly from water. After the smart crumb adsorbs hydrocarbons, it is then used to make asphalt products and the aqua fiber is used to replace sand and gravel in residential and commercial concrete and asphalt respectively.

  20. A Planar Quasi-Static Constraint Mode Tire Model

    Science.gov (United States)

    2015-07-10

    strikes a balance between simple tire models that lack the fidelity to make accurate chassis load predictions and computationally intensive models that...strikes a balance between heuristic tire models (such as a linear point-follower) that lack the fidelity to make accurate chassis load predictions...UNCLASSIFIED: Distribution Statement A. Cleared for public release A PLANAR QUASI-STATIC CONSTRAINT MODE TIRE MODEL Rui Maa John B. Ferris

  1. Performance of Used Tire Cushion Layer under Rockfall Impact

    OpenAIRE

    Sun, Jianhu; Chu, Zhaojun; Liu, Yingfang; Luo, Weiming; Wang, Min

    2016-01-01

    Rock shed is widely used in traffic lines against rockfall. In order to cushion rockfall impact and dissipate impact energy, cushion layer is usually adopted in rock shed. Used tire cushion layer is proposed in this paper and it can cushion rockfall impact utilizing large radial deformation of tire. Reinforced concrete structure model is built with used tire cushion layer and artificial rockfall test is carried out. Twelve tests are divided into 4 sets with different rockfall mass, rockfall h...

  2. Deterministic and Stochastic Semi-Empirical Transient Tire Models

    OpenAIRE

    Umsrithong, Anake

    2012-01-01

    The tire is one of the most important components of the vehicle. It has many functions, such as supporting the load of the vehicle, transmitting the forces which drive, brake and guide the vehicle, and acting as the secondary suspension to absorb the effect of road irregularities before transmitting the forces to the vehicle suspension. A tire is a complex reinforced rubber composite air container. The structure of the tire is very complex. It consists of several layers of synthetic polymer, ...

  3. The design and improvement of radial tire molding machine

    Science.gov (United States)

    Wang, Wenhao; Zhang, Tao

    2018-04-01

    This paper presented that the high accuracy semisteel meridian tire molding machine structure configurations, combining tyre high precision characteristics, the original structure and parameter optimization, technology improvement innovation design period of opening and closing machine rotary shaping drum institutions. This way out of the shaft from the structure to the push-pull type movable shaping drum of thinking limit, compared with the specifications and shaping drum can smaller contraction, is conducive to forming the tire and reduce the tire deformation.

  4. Role of non destructive techniques for monitoring structural integrity of primary circuit of pressurized water reactor nuclear power plant

    International Nuclear Information System (INIS)

    Sharma, P.K.; Sreenivas, P.

    2015-01-01

    The safety of nuclear installations is ensured by assessing status of primary equipment for performing the intended function reliably and maintaining the integrity of pressure boundaries. The pressure boundary materials undergo material degradation during the plant operation. Pressure boundary materials are subjected to operating stresses and material degradation that results in material properties changes, discontinuities initiation and increase in size of existing discontinuities. Pre-Service Inspection (PSI) is performed to generate reference base line data of initial condition of the pressure boundary. In-Service Inspections (ISI) are performed periodically to confirm integrity of pressure boundaries through comparison with respect to base line data. The non destructive techniques are deployed considering nature of the discontinuities expected to be generated through operating conditions and degradation mechanisms. The paper is prepared considering Pressurized Water Reactor (PWR) Nuclear Power Plant. The paper describes the degradation mechanisms observed in the PWR nuclear power plants and salient aspect of PSI and ISI and considerations in selecting non destructive testing. The paper also emphasises on application of acoustic emission (AE) based condition monitoring systems that can supplement in-service inspections for detecting and locating discontinuities in pressure boundaries. Criticality of flaws can be quantitatively evaluated by determining their size through in-service inspection. Challenges anticipated in deployment of AE based monitoring system and solutions to cater those challenges are also discussed. (author)

  5. Tracheal cuff pressure monitoring in the ICU: a literature review and survey of current practice in Queensland.

    Science.gov (United States)

    Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D

    2014-11-01

    The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.

  6. Cost-Effectiveness of Implantable Pulmonary Artery Pressure Monitoring in Chronic Heart Failure.

    Science.gov (United States)

    Sandhu, Alexander T; Goldhaber-Fiebert, Jeremy D; Owens, Douglas K; Turakhia, Mintu P; Kaiser, Daniel W; Heidenreich, Paul A

    2016-05-01

    This study aimed to evaluate the cost-effectiveness of the CardioMEMS (CardioMEMS Heart Failure System, St Jude Medical Inc, Atlanta, Georgia) device in patients with chronic heart failure. The CardioMEMS device, an implantable pulmonary artery pressure monitor, was shown to reduce hospitalizations for heart failure and improve quality of life in the CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) trial. We developed a Markov model to determine the hospitalization, survival, quality of life, cost, and incremental cost-effectiveness ratio of CardioMEMS implantation compared with usual care among a CHAMPION trial cohort of patients with heart failure. We obtained event rates and utilities from published trial data; we used costs from literature estimates and Medicare reimbursement data. We performed subgroup analyses of preserved and reduced ejection fraction and an exploratory analysis in a lower-risk cohort on the basis of the CHARM (Candesartan in Heart failure: Reduction in Mortality and Morbidity) trials. CardioMEMS reduced lifetime hospitalizations (2.18 vs. 3.12), increased quality-adjusted life-years (QALYs) (2.74 vs. 2.46), and increased costs ($176,648 vs. $156,569), thus yielding a cost of $71,462 per QALY gained and $48,054 per life-year gained. The cost per QALY gained was $82,301 in patients with reduced ejection fraction and $47,768 in those with preserved ejection fraction. In the lower-risk CHARM cohort, the device would need to reduce hospitalizations for heart failure by 41% to cost cost-effectiveness was most sensitive to the device's durability. In populations similar to that of the CHAMPION trial, the CardioMEMS device is cost-effective if the trial effectiveness is sustained over long periods. Post-marketing surveillance data on durability will further clarify its value. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights

  7. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index

    Directory of Open Access Journals (Sweden)

    Moreira Leila B

    2010-11-01

    Full Text Available Abstract Background Blood pressure (BP variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM. We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI. Methods and Results In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time, standard deviation (SD of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40 was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007. In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04. In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P Conclusion Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  8. European Society of Hypertension position paper on ambulatory blood pressure monitoring.

    Science.gov (United States)

    O'Brien, Eoin; Parati, Gianfranco; Stergiou, George; Asmar, Roland; Beilin, Laurie; Bilo, Grzegorz; Clement, Denis; de la Sierra, Alejandro; de Leeuw, Peter; Dolan, Eamon; Fagard, Robert; Graves, John; Head, Geoffrey A; Imai, Yutaka; Kario, Kazuomi; Lurbe, Empar; Mallion, Jean-Michel; Mancia, Giuseppe; Mengden, Thomas; Myers, Martin; Ogedegbe, Gbenga; Ohkubo, Takayoshi; Omboni, Stefano; Palatini, Paolo; Redon, Josep; Ruilope, Luis M; Shennan, Andrew; Staessen, Jan A; vanMontfrans, Gert; Verdecchia, Paolo; Waeber, Bernard; Wang, Jiguang; Zanchetti, Alberto; Zhang, Yuqing

    2013-09-01

    Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.

  9. Abnormalities in ambulatory blood pressure monitoring in hypertensive patients with diabetes.

    Science.gov (United States)

    Gorostidi, Manuel; de la Sierra, Alejandro; González-Albarrán, Olga; Segura, Julián; de la Cruz, Juan J; Vinyoles, Ernest; Llisterri, José L; Aranda, Pedro; Ruilope, Luis M; Banegas, José R

    2011-11-01

    Our aim was to assess the ambulatory blood pressure monitoring (ABPM) characteristics or patterns in hypertensive patients with diabetes compared with non-diabetic hypertensives. We performed a cross-sectional analysis of a 68,045 patient database from the Spanish Society of Hypertension ABPM Registry, a nation-wide network of >1200 primary-care physicians performing ABPM under standardized conditions in daily practice. We identified 12,600 (18.5%) hypertensive patients with diabetes. When compared with patients without diabetes, diabetic hypertensives exhibited higher systolic blood pressure (BP) levels in every ABPM period (daytime 135.4 vs. 131.8, and nighttime 126.0 vs. 121.0 mm Hg, P<0.001 for both) despite they were receiving more antihypertensive drugs (mean number 1.71 vs. 1.23, P<0.001). Consequently, diabetic patients suffered from lack of control of BP more frequently than non-diabetic subjects particularly during the night (65.5% vs. 57.4%, P<0.001). Prevalence of a non-dipping BP profile (64.2% vs. 51.6%, P<0.001) was higher in diabetic patients. In the other hand, prevalence of 'white-coat' hypertension in diabetic patients was 33.0%. We conclude that there was a remarkably high prevalence of alterations in ABPM in patients with diabetes. Abnormalities in systolic BP, particularly during the night, and in circadian BP pattern could be linked with the excess of BP-related cardiovascular risk of diabetes. A wider use of ABPM in diabetic patients should be considered.

  10. Master curve approach to monitor fracture toughness of reactor pressure vessels in nuclear power plants

    International Nuclear Information System (INIS)

    2009-10-01

    A series of coordinated research projects (CRPs) have been sponsored by the IAEA, starting in the early 1970s, focused on neutron radiation effects on reactor pressure vessel (RPV) steels. The purpose of the CRPs was to develop correlative comparisons to test the uniformity of results through coordinated international research studies and data sharing. The overall scope of the eighth CRP (CRP-8), Master Curve Approach to Monitor Fracture Toughness of Reactor Pressure Vessels in Nuclear Power Plants, has evolved from previous CRPs which have focused on fracture toughness related issues. The ultimate use of embrittlement understanding is application to assure structural integrity of the RPV under current and future operation and accident conditions. The Master Curve approach for assessing the fracture toughness of a sampled irradiated material has been gaining acceptance throughout the world. This direct measurement of fracture toughness approach is technically superior to the correlative and indirect methods used in the past to assess irradiated RPV integrity. Several elements have been identified as focal points for Master Curve use: (i) limits of applicability for the Master Curve at the upper range of the transition region for loading quasi-static to dynamic/impact loading rates; (ii) effects of non-homogeneous material or changes due to environment conditions on the Master Curve, and how heterogeneity can be integrated into a more inclusive Master Curve methodology; (iii) importance of fracture mode differences and changes affect the Master Curve shape. The collected data in this report represent mostly results from non-irradiated testing, although some results from test reactor irradiations and plant surveillance programmes have been included as available. The results presented here should allow utility engineers and scientists to directly measure fracture toughness using small surveillance size specimens and apply the results using the Master Curve approach

  11. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index.

    Science.gov (United States)

    Wittke, Estefânia; Fuchs, Sandra C; Fuchs, Flávio D; Moreira, Leila B; Ferlin, Elton; Cichelero, Fábio T; Moreira, Carolina M; Neyeloff, Jeruza; Moreira, Marina B; Gus, Miguel

    2010-11-05

    Blood pressure (BP) variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM). We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI). In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time), standard deviation (SD) of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40) was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007). In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04). In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P < 0.01). None of the other indexes of BP variability were associated with ABI in univariate and multivariate analyses. Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  12. Experiments on Spray from a Rolling Tire

    Science.gov (United States)

    Radovich, Charles; Browand, Fred

    2010-11-01

    A novel laboratory apparatus has been built to understand the mechanisms and statistics of droplet production for spray emerging from a rolling tire. Using high-speed imaging, water passing through a single circumferential groove was observed to leave the tire contact patch in the form of a liquid sheet of non-uniform thickness. The sheet breaks into droplets as a result of several, organized instabilities. Measurements for the breakup length of the liquid sheet showed a dependence on Weber number proportional to We-1/6, for Weber numbers of 2700, 10900 and 24400. A technique to identify and size water droplets was developed and the distribution of droplet sizes was determined as a function of Weber number. At We = 2700, droplet sizes between 80 and 9000μm were detected, with a mean diameter near 800μm. Both the range of droplet sizes and the mean diameter were found to decrease with increasing Weber number as (approximately) We-1/2. Correlation Image Velocimetry (CIV) was used to estimate the distribution of droplet velocities as a function of droplet size. The spread of droplet velocities about the tire peripheral speed is strongly correlated with droplet size. The spread can be estimated by a simple physical model incorporating rigid droplets subject to gravity and drag.

  13. Home Blood Pressure Monitoring as an Alternative to Confirm Diagnoses of Hypertension in Adolescents with Elevated Office Blood Pressure from a Brazilian State Capital

    Science.gov (United States)

    Póvoa, Thaís Inacio Rolim; Jardim, Thiago Veiga; Carneiro, Carolina de Souza; Ferreira, Vanessa Roriz; Mendonça, Karla Lorena; de Morais, Polyana Resende Silva; Nascente, Flávia Miquetichuc Nogueira; de Souza, Weimar Kunz Sebba Barroso; Sousa, Ana Luiza Lima; Jardim, Paulo César Brandão Veiga

    2017-01-01

    Background Regional differences of using home blood pressure monitoring (HBPM) as an alternative to ambulatory blood pressure monitoring (ABPM) in hypertensive adolescents are unknown. Objectives Define if HBPM is an option to confirm diagnoses of hypertension in adolescents from a Brazilian capital with elevated office blood pressure (BP). Methods Adolescents (12-18years) from public and private schools with BP > 90th percentile were studied to compare and evaluate the agreement among office BP measurements, HBPM and ambulatory BP monitoring. Office BP measurements, HBPM and ABPM were performed according to guidelines recommendations. Semi-automatic devices were used for BP measurements. Values of p ABPM values (120.3 ± 12.6 mmHg x 121.5 ± 9.8 mmHg - p = 0.111 and 69.4 ± 7.7 mmHg x 70.2 ± 6.6 mmHg - p = 0.139) and lower than the office measurement values (127.3 ± 13.8 mmHg over 74.4 ± 9.5 mmHg - p ABPM. Conclusions HBPM is an option to confirm diagnoses of hypertension in adolescents from a Brazilian state capital with elevated office BP and can be used as an alternative to ABPM. PMID:28793045

  14. In-plane Tire Deformation Measurement Using a Multi-Laser Sensor System

    OpenAIRE

    Xiong, Yi

    2016-01-01

    The interactions between tires and roads are basic mechanisms that alter the dynamic states of vehicles. A fundamental understanding of tire-road interactions is clearly demanded in tire design to achieve performance improvements. The emergence of various tire sensors provides an opportunity to make accurate measurement of the physical quantities that are involved in tire-road interactions.  This thesis aims to measure and analyze the in-plane deformation of rolling tires through its direc...

  15. Evaluation of indirect blood pressure monitoring in awake and anesthetized red-tailed hawks (Buteo jamaicensis): effects of cuff size, cuff placement, and monitoring equipment.

    Science.gov (United States)

    Zehnder, Ashley M; Hawkins, Michelle G; Pascoe, Peter J; Kass, Philip H

    2009-09-01

    To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Prospective, randomized, blinded study. Six, sex unknown, adult red-tailed hawks. Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.

  16. Impact of tire loading and tire pressure on measured 3D contact stresses

    CSIR Research Space (South Africa)

    Hernandez, JA

    2013-06-01

    Full Text Available Pavement 2013 D ow nl oa de d fro m a sc el ib ra ry .o rg b y G RA IN G ER E N G IN EE RI N G L IB E o n 10 /1 4/ 13 . C op yr ig ht A SC E. F or p er so na l u se o nl y; a ll rig ht s r es er ve d. 2 composed of a measuring mechanism... a v e m e n t 2 0 1 3 : S u s t a i n a b l e a n d E f f i c i e n t P a v e m e n t s © A S C E 2 0 1 3 A i r f i e l d a n d H i g h w a y P a v e m e n t 2 0 1 3 D ow nl oa de d fro m a sc el ib ra ry .o rg b y G RA IN G ER...

  17. Geotechnical Properties of Rubber Tires and Sediments Mixtures

    Directory of Open Access Journals (Sweden)

    H. Sellaf

    2014-04-01

    Full Text Available An experimental work was undertaken to study the effect of rubber tires on the geotechnical properties of a dredged sediment, using a mixing ratio of large size. For comparison, two types of soil were studied (dredged sediment from Fergoug dam and Tizi Tuff from the north west of Algeria. Taking into account the high compressibility and the low water absorption of the rubber tires, grain size analysis, density, Atterberg limits analysis, chemical composition, direct shear tests, loading-unloading tests, modified Proctor and CBR tests are performed on the two soils and their mixtures with different scrap tire rubber (10, 20, 25 and 50%. The results show that liquid limits and plastic indexes decrease with the scrap tire rubber content and that the decrease is more significant for soil with high plasticity. Cohesion also decreases with scrap tire rubber content when the internal friction angle is vacillating. Compression and recompression indexes increase gradually with the scrap tire rubber content and the variation for compression index is more significant for the two soils. Compaction characteristics and CBR values decrease with scrap tire rubber content. The CBR values for W=3% are important compared to those with W=5% excepted for mixture with (75% tuff and 25% scrap tire rubber. The results show that the scrap tire rubber can be used as a reinforcement material for dredged soil, but with a content that should not highly affect the compressibility.

  18. Who benefited from the US tariffs on the Chinese tires?

    OpenAIRE

    Joonhyung, Lee

    2011-01-01

    The purpose of this paper is to evaluate the short-run effect of the tariffs on Chinese tires imposed by the US in September 2009. First, we investigated whether the tariffs were beneficial to the US domestic tire industry in terms of employment. Our empirical analysis found that there were no significant benefits to US employment in the tire industry. This result led us to the next question: Who benefited from the tariffs? We found that the tire imports to the US were significantly deviated ...

  19. Method of sections in analytical calculations of pneumatic tires

    Science.gov (United States)

    Tarasov, V. N.; Boyarkina, I. V.

    2018-01-01

    Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.

  20. Environmental impact caused by incorrect discard of tires

    Directory of Open Access Journals (Sweden)

    Vitória Emanuella da Silva Alves

    2015-11-01

    Full Text Available Tires are wastes that need special treatment, because when buried whole, its shape facilitates the accumulation of gases from the decomposition of other waste and in case of emerge surface provides shelter for diseases. Thus, this research aimed to provide information about the environmental impacts caused by the improper disposal of unserviceable tires and about some techniques for reusing and recycling them. We opted for the literature search using databases SCIELO, GOOGLE SCHOLAR, CAPES journals, resolutions of the MMA, the ANIP and regulations of IBAMA instructions. The consultation material comprises a period from 1992 to 2015 with the following descriptors: industrial waste; laws of tires; environmental impacts caused by improper disposal of tires and technological alternatives usable by tires and scrap therefore improper disposal of scrap tires can cause negative impacts such as floods, by reducing the flow capacity of water bodies and drains. In contrast, after use, the tire can undergo reform and be reused, but the wear out is completely characterized as waste tire and the correct disposal are the possible ways of recycling. Thus it is very important compliance of laws that deal with the proper disposal of tires.

  1. USING THE SCRAP TIRES TO PRODUCE A FLEXIBLE COUPLER

    OpenAIRE

    Tahsean A. Hussain

    2018-01-01

    The scrap tires considered a problematic source of waste, the old rubber tires causes a big environmental problem that is need much money and effort to disposes it safely. In Iraq there are more than two million used tires disposed to the environment annually. one of the tire’s recycling methods is the use of tire layers to produce a new rubber parts used in the engineering and industrial purposes as the bridges and machines dampers, this trend of recycling doesn’t take a sufficient care comp...

  2. Implementation of Out-of-Office Blood Pressure Monitoring in the Netherlands: From Clinical Guidelines to Patients’ Adoption of Innovation

    NARCIS (Netherlands)

    Carrera, Percivil Melendez; Lambooij, Mattijs S.

    2015-01-01

    Out-of-office blood pressure monitoring is promoted by various clinical guidelines toward properly diagnosing and effectively managing hypertension and engaging the patient in their care process. In the Netherlands, however, the Dutch cardiovascular risk management (CVRM) guidelines do not

  3. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    Science.gov (United States)

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  4. Development of an Intelligent Tire Based Tire - Vehicle State Estimator for Application to Global Chassis Control

    OpenAIRE

    Singh, Kanwar Bharat

    2012-01-01

    The contact between the tire and the road is the key enabler of vehicle acceleration, deceleration and steering. However, under the circumstances of sudden changes to the road conditions, the driver`s ability to maintain control of the vehicle maybe at risk. In many cases, this requires intervention from the chassis control systems onboard the vehicle. Although these systems perform well in a variety of situations, their performance can be improved if a real-time estimate of the tire-road c...

  5. Association of Ambulatory Blood Pressure Monitoring parameters with the Framingham Stroke Risk Profile.

    Science.gov (United States)

    Tsivgoulis, Georgios; Pikilidou, Maria; Katsanos, Aristeidis H; Stamatelopoulos, Kimon; Michas, Fotios; Lykka, Aikaterini; Zompola, Christina; Filippatou, Angeliki; Boviatsis, Efstathios; Voumvourakis, Konstantinos; Zakopoulos, Nikolaos; Manios, Efstathios

    2017-09-15

    The Framingham Stroke Risk Profile (FSRP) is a novel and reliable tool for estimating the 10-year probability for incident stroke in stroke-free individuals, while the predictive value of ambulatory blood pressure monitoring (ABPM) for first-ever and recurrent stroke has been well established. We sought to evaluate cross-sectionally the association of ABPM parameters with FSRP score in a large sample of 2343 consecutive stroke-free individuals (mean age: 56.0±12.9, 49.1% male) who underwent 24-hour ABPM. True hypertensives showed significantly higher FSRP (11.2±5.0) compared to the normotensives (8.2±5.0, pbest fitting model for predicting FSRP (R 2 =24.6%) on multiple linear regression analyses after adjustment for vascular risk factors not included in FSRP comprised the following parameters in descending order: 24-hour PP (β=0.349, p<0.001), daytime SBP variability (β=0.124, p<0.001), 24-hour HR variability (β=-0.091, p<0.001), mean 24-hour HR (β=-0.107, p<0.001), BMI (β=0.081, p<0.001) and dipping percentage (β=-0.063, p=0.001). 24-hour PP and daytime SBP variability are the two ABPM parameters that were more strongly associated with FSRP-score. Reverse dippers had the highest FSRP among all dipping status profiles. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. 44-h ambulatory blood pressure monitoring: revealing the true burden of hypertension in pediatric hemodialysis patients.

    Science.gov (United States)

    Haskin, Orly; Wong, Cynthia J; McCabe, Lonisa; Begin, Brandy; Sutherland, Scott M; Chaudhuri, Abanti

    2015-04-01

    The blood pressure (BP) burden is high in pediatric hemodialysis (HD) patients and adversely affects prognosis. The aim of this study was to examine whether 44-h ambulatory BP monitoring (ABPM) provides additional relevant BP data compared with 24-h ABPM. ABPM was initiated at the end of the mid-week dialysis run in 13 stable pediatric HD patients and continued until the next run for 44 h. Day 1 was defined as the initial 24-h ABPM and Day 2 as the time period after that until the next dialysis run. All patients had an echocardiogram to calculate the left ventricular mass index (LVMI). A higher percentage of patients were diagnosed with hypertension from the 44-h ABPM than from the 24-h ABPM. All BP indexes and loads (except nighttime diastolic load) were significantly higher on Day 2 than on Day 1. Patients with BP loads of ≥ 25 % on 44-h ABPM had significantly higher LVMI than those patients with normal BP loads. No such association was found with 24-h ABPM and LVMI. Higher interdialytic weight gain was associated with higher Day-2 nighttime systolic BP load. The 44-h ABPM provides more information than the 24-h ABPM in terms of diagnosing and assessing the true burden of hypertension in pediatric HD patients. Elevated BP loads from 44-h ABPM correlate with a higher LVMI on the echocardiogram.

  7. The Use of Ambulatory Blood Pressure Monitoring Among Medicare Beneficiaries in 2007-2010

    Science.gov (United States)

    Shimbo, Daichi; Kent, Shia T; Diaz, Keith M; Huang, Lei; Viera, Anthony J; Kilgore, Meredith; Oparil, Suzanne; Muntner, Paul

    2014-01-01

    The US Centers for Medicaid and Medicare Services reimburses ambulatory blood pressure monitoring (ABPM) for suspected white coat hypertension. We estimated ABPM use between 2007 and 2010 among a 5% random sample of Medicare beneficiaries (≥ 65 years). In 2007, 2008, 2009 and 2010, the percentage of beneficiaries with ABPM claims was 0.10%, 0.11%, 0.10%, and 0.09% respectively. A prior diagnosis of hypertension was more common among those with versus without an ABPM claim (77.7% versus 47.0%). Among hypertensive beneficiaries, 95.2% of those with an ABPM claim were taking antihypertensive medication. Age 75-84 versus 65-74 years, having coronary heart disease, chronic kidney disease, multiple prior hypertension diagnoses, and having filled multiple classes of antihypertensive medication were associated with an increased odds for an ABPM claim among hypertensive beneficiaries. ABPM use was very low among Medicare beneficiaries and was not primarily used for diagnosing white coat hypertension in untreated individuals. PMID:25492832

  8. Clinical predictors and impact of ambulatory blood pressure monitoring in pediatric hypertension referrals.

    Science.gov (United States)

    Davis, Marguerite L; Ferguson, Michael A; Zachariah, Justin P

    2014-09-01

    Elevated blood pressure (BP) is rising in children. Significant proportions of children have reactive hypertension or masked hypertension, making ambulatory BP monitoring (ABPM) a valuable tool, although with potential economic implications. In youth referred for elevated BP, we sought clinic BP combinations that obviated the need for ABPM and to specify the economic role of ABPM. In a retrospective pediatric referral cohort (N = 170), we examine clinic systolic BP (SBP) predictors of components of ABPM hypertension and their combination. In economic analyses, we compared effectiveness and charges of three diagnostic pathways: (1) clinic BP alone; (2) abnormal clinic BP prompting ABPM; or (3) universal ABPM. ABPM hypertension occurred in 55 (32.4%) and reactive hypertension in 37 (21.8%), average automated (β = 0.208; 95% confidence interval, 0.027, 0.389; P = .03) and maximum auscultatory clinic SBP (β = 0.160; 95% confidence interval 0.022, 0.299; P = .02) were associated with ABPM SBP mean, but none predicted SBP load. No clinic SBP combination was associated with ABPM hypertension. Universal ABPM accrued the lowest average charge per hypertensive youth identified ($10,948). We did not identify a clinic SBP combination that predicted ABPM hypertension in youth referred for elevated BP. Universal ABPM, in this context, may be the most economically and clinically efficient diagnostic strategy. Copyright © 2014 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  9. Chronic Management of Hypertension after Stroke: The Role of Ambulatory Blood Pressure Monitoring

    Science.gov (United States)

    Castilla-Guerra, Luis; Fernandez-Moreno, Maria del Carmen

    2016-01-01

    Hypertension is the most important potentially reversible risk factor for stroke in all age groups; high blood pressure (BP) is also associated with increased risk of recurrent stroke in patients who have already had an ischemic or hemorrhagic event. Twenty-four hour ambulatory BP monitoring (ABPM) has become an important tool for improving the diagnosis and management of hypertension, and is increasingly used to assess patients with hypertension. Nevertheless, although ABPM devices are increasingly used for assessment of hypertension, their value in the chronic management of hypertension in patients with stroke has not been systematically studied. In fact, among large-scale randomized trials for secondary stroke prevention, only the Morbidity and Mortality After Stroke, Eprosartan Compared With Nitrendipine for Secondary Prevention trial included 24-hour ABPM. ABPM has demonstrated chronic disruption of the circadian rhythm of BP after acute phase of stroke and has shown higher sensitivity compared to office BP in evaluating the effectiveness of antihypertensive treatment among stroke survivors. High 24-hour BP is an independent predictor for cerebrovascular events, brain microbleeds, and subsequent development of dementia. Nevertheless, although stroke care guidelines endorse the importance of hypertension management, the specific role of ABPM among stroke survivors after the acute phase of disease has not been established. Further studies are needed to clarify whether routine application of ABPM among these patients should be recommended. PMID:26687120

  10. Nurse-Driven Training Courses: Impact on Implementation of Ambulatory Blood Pressure Monitoring

    Science.gov (United States)

    Félez-Carrobé, Estel; Sagarra-Tió, Maria; Romero, Araceli; Rubio, Montserrat; Planas, Lourdes; Pérez-Lucena, María José; Baiget, Montserrat; Cabistañ, Cristina; Félez, Jordi

    2013-01-01

    Background: Ambulatory blood pressure monitoring (ABPM) predicts cardiovascular risk and identifies white-coat and masked hypertension, efficacy of treatment and the circadian cycle of hypertensive patients. Objective: To analyze the effectiveness of ABPM implementation thoughtout a nurse-driven training program. Materials and Methodology: Twenty eight professionals were involved in the study carried out in the primary care center of the metropolitan area of Barcelona that serves 34,289 inhabitants. The ABPM implementation program was driven by two nurses that held four education sessions. After a 2-year follow-up period, we assessed the outcome of attendance at the educational sessions. First, we evaluated whether the program increased the number of orders of ABPM. Second, we used a survey to evaluate to what extent the input of our educational sessions was understood by attendants. Third, we analyzed the effect ABPM results had on the treatment of patients with a bad control of their hypertension. Results: After the training sessions we found a 6-fold increase in the number of patients undergoing ABPM. We analyzed 204 hypertensive individuals: 41% dippers, 34% were non-dippers, 20% were risers and 5% were extremely dippers. According to our survey, 100% of attendants had a good practice regarding ABPM management. However only 27% of riser patients were studied with a second ABPM. Conclusions: Specific training processes are needed for implementation of ABPM and an even more concentrated effort should be focused on training in the correct interpretation of ABPM results. PMID:23750185

  11. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    Science.gov (United States)

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  12. Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring.

    Science.gov (United States)

    Sartiano, Demetrio; Sales, Salvador

    2017-12-13

    The aim of this paper is to report the design of a low-cost plastic optical fiber (POF) pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm) and a silicon light sensor. The Super ESKA ® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2-5 s (0.2-0.5 Hz). The sensor has a resolution of force applied on a single point of 2.2-4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.

  13. A Tilt, Soil Moisture, and Pore Water Pressure Sensor System for Slope Monitoring Applications

    Directory of Open Access Journals (Sweden)

    Rosanno de Dios

    2009-06-01

    Full Text Available This paper describes the design, implementation and characterization of a sensor network intended for monitoring of slope deformation and potential failures. The sensor network system consists of a tilt and moisture sensor column, a pore water pressure sensor column and a personal computer for data storage and processing. The tilt sensor column consists of several pipe segments containing tri-axial accelerometers and signal processing electronics. Each segment is joined together by flexible joints to allow for the column to deform and subsequently track underground movement. Capacitive-type sensors for soil moisture measurement are also included in the sensor column, which are used to measure the soil moisture at different depths. The measurements at each segment are transferred via a Controller Area Network (CAN bus, where the CAN master node is located at the top of the column above ground. The CAN master node transmits the collected data from the slave nodes via a wireless connection to a personal computer that performs data storage, processing and display via a Python-based graphical user interface (GUI. The entire system was deployed and characterized on a small-scale slope model. Slope failure was induced via water seepage and the system was demonstrated to ably measure the inclination and soil moisture content throughout the landslide event.

  14. Using a home blood pressure monitor: do accompanying instructional materials meet low literacy guidelines?

    Science.gov (United States)

    Wallace, Lorraine S; Keenum, Amy J

    2008-08-01

    To evaluate the readability and related features of English language Quick Reference Guides (QRGs) and User Manuals (UMs) accompanying home blood pressure monitors (HBPMs). We evaluated QRGs and UMs for 22 HBPMs [arm (n=12); wrist (n=10)]. Using established criteria, we evaluated reading grade level, language availability, dimensions, text point size, use of illustrations, layout/formatting characteristics, and emphasis of key points of English-language patient instructions accompanying HBPMs. Readability was calculated using McLaughlin's Simplified Measure of Gobbledygoop. Items from the Suitability of Materials Assessment and User-Friendliness Tool were used to assess various layout features. Simplified Measure of Gobbledygoop scores of both QRGs (mean+/-SD=9.1+/-0.8) and UMs (9.3+/-0.8) ranged from 8th to 10th grade. QRGs and UMs presented steps in chronological order, used active voice throughout, avoided use of specialty fonts, focused on need to know, and used realistic illustrations. Seven sets of instructions included all seven key points related to proper HPBM use, whereas three sets of instructions included less than or equal to three key points (mean=4.8+/-1.9). Although most QRGs and UMs met at least some recommended low-literacy formatting guidelines, all instructional materials should be developed and tested to meet the needs of the patient population at large. Key points related to proper HBPM use should not only be included within these instructions, but highlighted to emphasize their importance.

  15. Low Cost Plastic Optical Fiber Pressure Sensor Embedded in Mattress for Vital Signal Monitoring

    Directory of Open Access Journals (Sweden)

    Demetrio Sartiano

    2017-12-01

    Full Text Available The aim of this paper is to report the design of a low-cost plastic optical fiber (POF pressure sensor, embedded in a mattress. We report the design of a multipoint sensor, a cheap alternative to the most common fiber sensors. The sensor is implemented using Arduino board, standard LEDs for optical communication in POF (λ = 645 nm and a silicon light sensor. The Super ESKA® plastic fibers were used to implement the fiber intensity sensor, arranged in a 4 × 4 matrix. During the breathing cycles, the force transmitted from the lungs to the thorax is in the order of tens of Newtons, and the respiration rate is of one breath every 2–5 s (0.2–0.5 Hz. The sensor has a resolution of force applied on a single point of 2.2–4.5%/N on the normalized voltage output, and a bandwidth of 10 Hz, it is then suitable to monitor the respiration movements. Another issue to be addressed is the presence of hysteresis over load cycles. The sensor was loaded cyclically to estimate the drift of the system, and the hysteresis was found to be negligible.

  16. Acoustic Behavior of Hollow Blocks and Bricks Made of Concrete Doped with Waste-Tire Rubber

    Directory of Open Access Journals (Sweden)

    Esteban Fraile-Garcia

    2016-11-01

    Full Text Available In this paper, we investigate the acoustic behaviour of building elements made of concrete doped with waste-tire rubber. Three different mixtures were created, with 0%, 10%, and 20% rubber in their composition. Bricks, lattice joists, and hollow blocks were manufactured with each mixture, and three different cells were built and tested against aerial and impact noise. The values of the global acoustic isolation and the reduction of the sound pressure level of impacts were measured. Results proved that highly doped elements are an excellent option to isolate low frequency sounds, whereas intermediate and standard elements constitute a most interesting option to block middle and high frequency sounds. In both cases, the considerable amount of waste-tire rubber recycled could justify the employment of the doped materials for the sake of the environment.

  17. Validation of A&D TM-2430 upper-arm blood pressure monitor for ambulatory blood pressure monitoring in children and adolescents, according to the British Hypertension Society protocol.

    Science.gov (United States)

    Yip, Gabriel Wai-Kwok; So, Hung-Kwan; Li, Albert Martin; Tomlinson, Brian; Wong, Sik-Nin; Sung, Rita Yn-Tz

    2012-04-01

    The A&D TM-2430 ambulatory blood pressure (BP) monitor has been validated in adults but not in a young population. We sought to validate the device monitoring in children and adolescents, according to the British Hypertension Society (BHS) protocol. The A&D TM-2430 is an automated oscillometric upper-arm device for ambulatory BP monitoring. Nine consecutive measurements were taken in 61 children (mean age, 9.8 years; range, 5-15 years) according to the BHS criteria. Overseen by an independent supervisor, measurements were recorded by two observers blinded from each other's readings and from the device readings. The mean difference ± SD between the observers and device measurements was 0.73 ± 1.64 mmHg for systolic blood pressure (SBP) and -1.23 ± 1.65 mmHg for diastolic blood pressure (DBP), respectively, with an interobserver difference of 4 mmHg. The cumulative percentages of differences within 5, 10, and 15 mmHg were 89, 95, and 98% for SBP and 67, 88, and 98% for DBP. The device achieved a grade A rating for SBP and a B grade for DBP. The A&D TM-2430 upper-arm BP monitor has fulfilled the required BHS standards and can be recommended for measuring ambulatory BP in children and adolescent populations.

  18. Methodology and technology for peripheral and central blood pressure and blood pressure variability measurement: current status and future directions - Position statement of the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability.

    Science.gov (United States)

    Stergiou, George S; Parati, Gianfranco; Vlachopoulos, Charalambos; Achimastos, Apostolos; Andreadis, Emanouel; Asmar, Roland; Avolio, Alberto; Benetos, Athanase; Bilo, Grzegorz; Boubouchairopoulou, Nadia; Boutouyrie, Pierre; Castiglioni, Paolo; de la Sierra, Alejandro; Dolan, Eamon; Head, Geoffrey; Imai, Yutaka; Kario, Kazuomi; Kollias, Anastasios; Kotsis, Vasilis; Manios, Efstathios; McManus, Richard; Mengden, Thomas; Mihailidou, Anastasia; Myers, Martin; Niiranen, Teemu; Ochoa, Juan Eugenio; Ohkubo, Takayoshi; Omboni, Stefano; Padfield, Paul; Palatini, Paolo; Papaioannou, Theodore; Protogerou, Athanasios; Redon, Josep; Verdecchia, Paolo; Wang, Jiguang; Zanchetti, Alberto; Mancia, Giuseppe; O'Brien, Eoin

    2016-09-01

    Office blood pressure measurement has been the basis for hypertension evaluation for almost a century. However, the evaluation of blood pressure out of the office using ambulatory or self-home monitoring is now strongly recommended for the accurate diagnosis in many, if not all, cases with suspected hypertension. Moreover, there is evidence that the variability of blood pressure might offer prognostic information that is independent of the average blood pressure level. Recently, advancement in technology has provided noninvasive evaluation of central (aortic) blood pressure, which might have attributes that are additive to the conventional brachial blood pressure measurement. This position statement, developed by international experts, deals with key research and practical issues in regard to peripheral blood pressure measurement (office, home, and ambulatory), blood pressure variability, and central blood pressure measurement. The objective is to present current achievements, identify gaps in knowledge and issues concerning clinical application, and present relevant research questions and directions to investigators and manufacturers for future research and development (primary goal).

  19. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the ‘white-coat’ effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-01-01

    Background Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a ‘white-coat’ effect. Aim To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Design and setting Retrospective study in a teaching hospital in Birmingham. Method Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Result Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Conclusion Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the ‘white-coat’ effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm. PMID:23561681

  20. Inter-arm blood pressure differences compared with ambulatory monitoring: a manifestation of the 'white-coat' effect?

    Science.gov (United States)

    Martin, Una; Holder, Roger; Hodgkinson, James; McManus, Richard

    2013-02-01

    Inter-arm difference in blood pressure of >10 mmHg is associated with peripheral vascular disease, but it is unclear how much of the difference in sequential right and left arm blood pressure measurements might be due to a 'white-coat' effect. To use ambulatory blood pressure monitoring (ABPM) to better understand the clinical significance of inter-arm differences in blood pressure. Retrospective study in a teaching hospital in Birmingham. Anonymised clinical data collected from 784 patients attending a single hospital-based hypertension clinic were retrospectively analysed. Each participant had blood pressure measured sequentially in both arms, followed by ABPM over the subsequent 24 hours. Data were available for 710 (91%) patients, of whom 39.3% (279) had a blood pressure difference of 10 mmHg or more between each arm. Compared to daytime systolic ABPM, the difference was 25.1 mmHg using the arm with the highest reading, but only 15.5 mmHg if the lower reading was taken (mean difference 9.6 mmHg (95% confidence interval [CI] = 9.0 mmHg to 10.3 mmHg)). However, differences between mean right (20.7 mmHg) or left (19.9 mmHg) arm blood pressure and daytime systolic ABPM were very similar. Compared with ABPM, use of the higher of the left and right arm readings measured sequentially appears to overestimate true mean blood pressure. As there is no significant difference in the extent of disparity with ABPM by left or right arm, this is unlikely to be due to arm dominance and may be due to the 'white-coat' effect reducing blood pressure on repeated measurement. Where a large inter-arm blood pressure difference is detected with sequential measurement, healthcare professionals should re-measure the blood pressure in the original arm.

  1. Combined application of FBG and PZT sensors for plantar pressure monitoring at low and high speed walking.

    Science.gov (United States)

    Suresh, R; Bhalla, S; Singh, C; Kaur, N; Hao, J; Anand, S

    2015-01-01

    Clinical monitoring of planar pressure is vital in several pathological conditions, such as diabetes, where excess pressure might have serious repercussions on health of the patient, even to the extent of amputation. The main objective of this paper is to experimentally evaluate the combined application of the Fibre Bragg Grating (FBG) and the lead zirconate titanate (PZT) piezoceramic sensors for plantar pressure monitoring during walk at low and high speeds. For fabrication of the pressure sensors, the FBGs are embedded within layers of carbon composite material and stacked in an arc shape. From this embedding technique, average pressure sensitivity of 1.3 pm/kPa and resolution of nearly 0.8 kPa is obtained. These sensors are found to be suitable for measuring the static and the low-speed walk generated foot pressure. Simultaneously, PZT patches of size 10 × 10 × 0.3 mm were used as sensors, utilizing the d_{33} (thickness) coupling mode. A sensitivity of 7.06 mV/kPa and a pressure resolution of 0.14 kPa is obtained from these sensors, which are found to be suitable for foot pressure measurement during high speed walking and running. Both types of sensors are attached to the underside of the sole of commercially available shoes. In the experiments, a healthy male subject walks/runs over the treadmill wearing the fabricated shoes at various speeds and the peak pressure is measured using both the sensors. Commercially available low-cost hardware is used for interrogation of the two sensor types. The test results clearly show the feasibility of the FBG and the PZT sensors for measurement of plantar pressure. The PZT sensors are more accurate for measurement of pressure during walking at high speeds. The FBG sensors, on the other hand, are found to be suitable for static and quasi-dynamic (slow walking) conditions. Typically, the measured pressure varied from 400 to 600 kPa below the forefoot and 100 to 1000 kPa below the heel as the walking speed varied from 1

  2. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    Science.gov (United States)

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  3. Ambulatory blood pressure monitoring in essential hypertensive patients with acute ischaemic stroke

    Directory of Open Access Journals (Sweden)

    S. P. Zhemanyuk

    2016-12-01

    Full Text Available Blood pressure (BP has been identified as a risk factor for various health disorders, including stroke onsets. Hypertension is one of the crucial health problem among adult Ukrainian. Due to the importance of elevated BP in stroke causality, BP measurement remains critical. However, it is limited information about value in clinical practice of ambulatory blood pressure monitoring (ABPM data in hypertensive patients with inadequately controlled BP with acute stroke compared with those individuals who has no vascular onset. The aim of the study was to determine ABPM parameters in essential hypertensive patients with ischaemic hemisphere stroke. Materials and methods. A total of 114 study participants were analyzed (mean age 62 (56;72 years, 40 % women. We divided them into two groups according to the level of 24-h systolic BP (SBP and diastolic BP (DBP, and the results of clinical examination. The first group (n=83 were inadequately controlled essential hypertensive individuals with high systolic or/and diastolic BP level according to the ABMP results, and the second one (n=31 were EH patients with an acute hemispheric ischaemic stroke (IS. Diagnosis of stroke was confirmed with clinical examination and computed tomography scan or magnetic resonance imaging results, and ABPM was conducted in 4.2±2.3 days after the stroke onset. Results. We had statistician difference (p<0.001 between groups of such parameters, as average SBP (diurnal, daytime, nighttime; diurnal pulse BP; SBP load (p<0.05; the diurnal AASI (p<0.05; circadian rhythm of DBP (p<0.05. No differences were found between the groups in morning surge calculated as speed and amplitude of the BP climbed in morning hours both for SBP (P=0.422 and P=0.395, respectively and DBP (P=0.860 and P=0.337, respectively. Conclusion. In the present study, we evaluated the ABPM parameters in inadequately controlled essential hypertensive individuals with and without acute ischaemic hemispheric stroke

  4. Twenty-four-hour ambulatory blood pressure monitoring in very elderly patients

    Science.gov (United States)

    Cappelleri, Claudia; Janoschka, Alin; Berli, Reto; Kohler, Sibylle; Braun-Dullaeus, Ruediger C.; Heuss, Ludwig T.; Wolfrum, Mathias

    2017-01-01

    Abstract Elevated blood pressure (BP) is frequently diagnosed in very elderly hospitalized patients. Accurate diagnosis of hypertension is challenging in the hospital environment, due to the “white coat effect,” and both overtreatment and undertreatment can adversely affect clinical outcome. Twenty-four-hour ambulatory blood pressure monitoring (ABPM) has the potential to avoid the “white coat effect” and accurately guide the management of hypertension. However, effects of the hospital environment on ABPM are unknown in the very elderly. We set out to enroll 45 patients, age ≥70 years, with elevated conventional BP during hospitalization in this observational study. It was prespecified by protocol to assess initially the difference between 24-hour BP during hospital-admission and home follow-up. Subsequent analysis should investigate the change in anxiety (Hospital Anxiety and Depression Scale-A [HADS-A]) after discharge, the correlation with change in 24-hour BP after discharge, and the prevalence of orthostatic hypertension. Thirty-one patients were included in the final analysis (age 83.5 ± 4.4 years; 71% female). Twenty-four-hour BP decreased significantly after hospital discharge (systolic from 133.5 ± 15.6 to 126.2 ± 14.4 mm Hg [millimeter of mercury], P = .008; diastolic from 71.0 ± 9.0 to 68.3 ± 8.6 mm Hg, P = .046). Anxiety level (HADS-A) decreased significantly after discharge, from 7.5 (interquartile range [IQR]: 4.0–13.8) to 5.0 (IQR: 4.0–8.0, P = .012). The change in anxiety was a predictor of change in systolic BP after discharge (F[1,20] = 5.9, P = .025). Sixty-one percent of the patients had significant orthostatic hypotension during hospital stay. In conclusion, 24-hour BP in very elderly patients is lower in the home environment than during hospitalization. This phenomenon seems to be directly linked to a lower anxiety-level at home. Reassessing hypertension at home may decrease the

  5. 1B.08: USEFULNESS OF 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING IN PEOPLE LIVING WITH HIV.

    Science.gov (United States)

    Nuernberg, M; Lang, S; Curjol, A; Haddour, N; Ederhy, S; Asri, C El; Dufour-Soulat, L; Van Der Vynckt, C; Charbonnier, M; Cohen, A; Boccara, F

    2015-06-01

    This study aimed to determine the utility of 24-hour ambulatory blood pressure monitoring (ABPM) in a priori normotensive and known hypertensive people living with HIV by quantifying new hypertension (HTN), masked hypertension, uncontrolled BP, and white coat effect. Data analysed was from the Register of cardiovascular Complications among people living with HIV (RECOVIH), including 263 HIV+ individuals with 1 or more CV risk factors who underwent 24-h ABPM in our cardiac centre.Diagnostic criteria:Elevated clinic BP: at or above 140/90 mmHgElevated mean 24-h ABPM: at or above 130/80 mmHg, systolic and/or diastolicNew hypertension: elevated clinic BP and/or elevated mean 24-h ABPMMasked hypertension: normal clinic BP and elevated mean 24-h ABPMUncontrolled BP: elevated clinic BP and/or elevated mean 24 h ABPM, in known HTNWhite coat effect: elevated clinic BP and normal mean 24-h ABPM, in a priori normotensives. The cohort had a mean age of 50.3 ± 7.7 years, was predominantly male (91%), had a long median HIV duration (15.3 years), and included 150 (57%) known HTN.In RECOVIH the prevalence of new HTN was 22% (n = 25), of which 50% masked hypertension diagnosed by 24-h ABPM solely. Uncontrolled HTN prevalence was 45% using clinic BP alone and 32% using 24-h ABPM alone. 24-h ABPM revealed that this masked uncontrolled HTN was frequently due to poor nocturnal BP control. White coat effect prevalence was not significantly different between the 2 groups (6.3% a priori normotensives vs. 9.3% known HTN, p = 0.37).HTN subjects were older, had higher BMI, and more frequently had a history of diabetes, coronary heart disease, and heart failure as compared to normotensives. Masked hypertension prevalence is high in RECOVIH, particularly among a priori normotensives. Suboptimal BP control is frequent among patients with treated and well-controlled clinic BP. Clinic BP monitoring alone is inadequate to diagnose HTN and assess true BP control because elevated

  6. An evaluation and comparison of intraventricular, intraparenchymal, and fluid-coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury.

    Science.gov (United States)

    Vender, John; Waller, Jennifer; Dhandapani, Krishnan; McDonnell, Dennis

    2011-08-01

    Intracranial pressure measurements have become one of the mainstays of traumatic brain injury management. Various technologies exist to monitor intracranial pressure from a variety of locations. Transducers are usually placed to assess pressure in the brain parenchyma and the intra-ventricular fluid, which are the two most widely accepted compartmental monitoring sites. The individual reliability and inter-reliability of these devices with and without cerebrospinal fluid diversion is not clear. The predictive capability of monitors in both of these sites to local, regional, and global changes also needs further clarification. The technique of monitoring intraventricular pressure with a fluid-coupled transducer system is also reviewed. There has been little investigation into the relationship among pressure measurements obtained from these two sources using these three techniques. Eleven consecutive patients with severe, closed traumatic brain injury not requiring intracranial mass lesion evacuation were admitted into this prospective study. Each patient underwent placement of a parenchymal and intraventricular pressure monitor. The ventricular catheter tubing was also connected to a sensor for fluid-coupled measurement. Pressure from all three sources was measured hourly with and without ventricular drainage. Statistically significant correlation within each monitoring site was seen. No monitoring location was more predictive of global pressure changes or more responsive to pressure changes related to patient stimulation. However, the intraventricular pressure measurements were not reliable in the presence of cerebrospinal fluid drainage whereas the parenchymal measurements remained unaffected. Intraparenchymal pressure monitoring provides equivalent, statistically similar pressure measurements when compared to intraventricular monitors in all care and clinical settings. This is particularly valuable when uninterrupted cerebrospinal fluid drainage is desirable.

  7. Final Scientific Report - "Improved Fuel Efficiency from Nanocomposite Tire Tread"

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Andrew Myers

    2005-12-30

    Rolling resistance, a measure of the energy lost as a tire rotates while moving, is a significant source of power and fuel loss. Recently, low rolling resistant tires have been formulated by adding silica to tire tread. These "Green Tires" (so named from the environmental advantages of lower emissions and improved fuel economy) have seen some commercial success in Europe, where high fuel prices and performance drive tire selection. Unfortunately, the higher costs of the silica and a more complicated manufacturing process have prevented significant commercialization - and the resulting fuel savings - in the U.S. In this project, TDA Research, Inc. (TDA) prepared an inexpensive alternative to silica that leads to tire components with lower rolling resistance. These new tire composite materials were processed with traditional rubber processing equipment. We prepared specially designed nanoparticle additives, based on a high purity, inorganic mineral whose surface can be easily modified for compatibility with tire tread formulations. Our nanocomposites decreased energy losses to hysteresis, the loss of energy from the compression and relaxation of an elastic material, by nearly 20% compared to a blank SBR sample. We also demonstrated better performance than a leading silica product, with easier production of our final rubber nanocomposite.

  8. 14 CFR 27.475 - Tires and shock absorbers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Tires and shock absorbers. 27.475 Section 27.475 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Strength Requirements Ground Loads § 27.475 Tires and shock absorbers. Unless otherwise prescribed...

  9. 14 CFR 29.475 - Tires and shock absorbers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Tires and shock absorbers. 29.475 Section 29.475 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Strength Requirements Ground Loads § 29.475 Tires and shock absorbers. Unless otherwise...

  10. The experimental assessment of dynamic tire handling performance

    NARCIS (Netherlands)

    Pauwelussen, J.P.

    1999-01-01

    Testing of steady state tire handling performance is nowadays common practice with slip angle sweeps and breaking being simulated in the laboratory with drum or flat belt, or on the road with a test trailer. In recent years, more emphasis is put on dynamic tire models, motivated by ride comfort

  11. Enhanced friction modeling for steady-state rolling tires

    NARCIS (Netherlands)

    Steen, van der R.

    2010-01-01

    Tire modeling is nowadays a necessary tool in the tire industry. Car manufacturers, governments and consumers demand better traction under all circumstances, less wear and more recently less noise and a lower rolling resistance. Therefore finite element analysis is adopted in the design process of

  12. Tire Production and Pollution Control. Environmental Education Curriculum. Revised.

    Science.gov (United States)

    Topeka Public Schools, KS.

    This unit was developed to introduce secondary students to the many facets of a typical, large manufacturing plant - the Topeka Goodyear Tire and Rubber Company - in an effort to increase awareness of sound environmental practices in industry. Its five major foci include the production of tires and quality control procedures; applications of…

  13. PA.NET International Quality Certification Protocol for blood pressure monitors.

    Science.gov (United States)

    Omboni, Stefano; Costantini, Carlo; Pini, Claudio; Bulegato, Roberto; Manfellotto, Dario; Rizzoni, Damiano; Palatini, Paolo; O'brien, Eoin; Parati, Gianfranco

    2008-10-01

    Although standard validation protocols provide assurance of the accuracy of blood pressure monitors (BPMs), there is no guidance for the consumer as to the overall quality of a device. The PA.NET International Quality Certification Protocol, developed by the Association for Research and Development of Biomedical Technologies and for Continuing Medical Education (ARSMED), a nonprofit organization, with the support of the Italian Society of Hypertension-Italian Hypertension League, and the dabl Educational Trust denotes additional criteria of quality for BPMs that fulfilled basic validation criteria, published in full in peer-reviewed medical journals. The certification is characterized by three phases: (i) to determine that the device fulfilled standard validation criteria; (ii) to determine the technical and functional characteristics of the device (e.g. operativity, display dimension, accessory functions, memory availability, etc.) and (iii) to determine the commercial characteristics (e.g. price-quality ratio, after-sale service, guarantee, etc.). At the end of the certification process, ARSMED attributes a quality index to the device, based on a scale ranging from 1 to 100, and a quality seal with four different grades (bronze, silver, gold and diamond) according to the achieved score. The seal is identified by a unique alphanumeric code. The quality seal may be used on the packaging of the appliance or in advertising. A quality certification is released to the manufacturer and published on www.pressionearteriosa.net and www.dableducational.org. The PA.NET International Quality Certification Protocol represents the first attempt to provide health care personnel and consumers with an independent and objective assessment of BPMs based on their quality.

  14. The effect of siesta in parameters of cardiac structure and in interpretation of ambulatory arterial blood pressure monitoring

    Directory of Open Access Journals (Sweden)

    Marco A.M. Gomes

    2000-04-01

    Full Text Available OBJECTIVE: To evaluate the influence of the siesta in ambulatory blood pressure (BP monitoring and in cardiac structure parameters. METHODS: 1940 ambulatory arterial blood pressure monitoring tests were analyzed (Spacelabs 90207, 15/15 minutes from 7:00 to 22:00 hours and 20/20 minutes from 22:01 to 6.59hours and 21% of the records indicated that the person had taken a siesta (263 woman, 52±14 years. The average duration of the siesta was 118±58 minutes. RESULTS: (average ± standard deviation The average of systolic/diastolic pressures during wakefulness, including the napping period, was less than the average for the period not including the siesta (138±16/85±11 vs 139±16/86±11 mmHg, p5%. CONCLUSION: The siesta influenced the heart structure parameters and from a statistical point of view the average of systolic and diastolic pressures and the respective pressure loads of the wakeful period.

  15. Microtomography of elastomers for tire manufacture

    Science.gov (United States)

    Dunsmuir, John H.; Dias, A. J.; Peiffer, D. G.; Kolb, R.; Jones, G.

    1999-09-01

    X-ray microtomography is used to image the internal structure of carbon black filled isobutylene-p-methylstyrene-p- bromomethylstyrene (PIB-PMS/BrPMS or ExxProTM) curing bladders before and after use-to-failure in the manufacture of automobile tires. Curing bladders operate under extreme conditions with extended mechanical cycling at high temperatures. Manufacturers typically do not run the bladders until failure but rather a pull policy is established which emphasizes the distribution of cyclic lifetimes. We examine the bladder elastomer structure at a resolution of about 10 microns with the objective of reducing the variability in performance. Using both edge crossing and absorption contrast we identify several types of heterogeneity including voids, foreign inclusions, and the distribution of curative agent from which we infer the uniformity of the cure. The results indicate several potential failure mechanisms. The small number of voids and foreign inclusions are mechanical defects that can initiate cracking. More widespread through the polymer matrix are small regions of polymer devoid of curative agent as shown by absorption edge imaging. These regions may be uncured polymer with poor mechanical and thermal properties that may lead to early failure. After several cure cycles the uncured regions are no longer present in the bladder tread area but they remain near the bead. At high cycles an approximately 500 micrometer thick zinc rich cap develops where the bladder contacts the inner tread area of the tire. This zinc rich cap may cause over-curing of the polymer resulting in crack initiation at the surface of the bladder that contacts the tire.

  16. Replacing coal by tire powder in ceramic industry

    Energy Technology Data Exchange (ETDEWEB)

    Mothe, C.G. [Dept. de Processos Organicos, Escola de Quimica/CT/UFRJ, Rio de Janeiro, RJ (Brazil); Mothe Filho, H.F. [Dept. de Geociencias, Inst. de Agronomia/UFRRJ, Seropedica, RJ (Brazil)

    2005-07-01

    Nowadays preserving nature, recycling or reusing materials are good policies. Around ten million tires are put out by year in Brazil, and it is not known for how long they will remain in environment till their complete degradation. This research used tires to replace coal in ceramic processing. In this way it helps to protect environment, to reduce the consumption of mineral deposits and to save money. Results show that tire powder can replace coal to obtain ceramic material, using one percent of tire. Experiments were carried out using TA instruments SDT 2960, in air or nitrogen atmospheres, at heating rate of 10 C/min., flow 120 ml/min. TG/DTA curves of tire and coal have exothermic events at close temperatures between 450-600 C. At range of temperatures clay have endothermic events. (orig.)

  17. Distribution of sulphur into products from waste tire pyrolysis

    International Nuclear Information System (INIS)

    Susa, D.; Haydary, J.; Markos, J.

    2012-01-01

    Tire pyrolysis is getting growing attention as an effective waste tire disposal method in comparison to environmentally less friendly methods like dumping or incineration. But the scrap tire sulphur content can be a potential obstacle to scrap tire utilization as a fuel. In this paper the distribution of sulphur into tire pyrolysis yields, solid (char) and liquid (tar), was investigated. The pyrolysis experiments were carried out under different conditions to determine the partitioning of sulphur into pyrolysis products. The influence of different temperatures and reaction times was investigated in a laboratory flow reactor under nitrogen atmosphere. Solid and liquid residues were collected and analyzed by elemental analysis. The sulphur content in residual char and tar was determined using an elemental analyzer and the sulphur forms in tar were characterized by the X-ray photoelectron spectroscopy (XPS). (Authors)

  18. Ambulatory blood pressure monitoring after 1 year on valsartan or amlodipine-based treatment: a VALUE substudy

    DEFF Research Database (Denmark)

    Pedersen, Ole Lederballe; Mancia, Giuseppe; Pickering, Thomas

    2007-01-01

    OBJECTIVE: The ambulatory blood pressure (ABP) monitoring substudy of the Valsartan Antihypertensive Long-term Use Evaluation (VALUE) trial was carried out in a subset of patients from USA, Italy and Denmark. ABP was measured after 1 year in the trial, with the aim of evaluating comparability...... of ABP levels on valsartan (VAL) and amlodipine (AML)-based regimens. METHODS: ABP was measured every 20 min during a 25-h period after morning administration of medicine; 659 patients were available for intention-to-treat analysis. RESULTS: Office blood pressure (BP) differences were smaller than...

  19. A composite material based on recycled tires

    Science.gov (United States)

    Malers, L.; Plesuma, R.; Locmele, L.

    2009-01-01

    The present study is devoted to the elaboration and investigation of a composite material based on mechanically grinded recycled tires and a polymer binder. The correlation between the content of the binder, some technological parameters, and material properties of the composite was clarified. The apparent density, the compressive stress at a 10% strain, the compressive elastic modulus in static and cyclic loadings, and the insulating properties (acoustic and thermal) were the parameters of special interest of the present investigation. It is found that a purposeful variation of material composition and some technological parameters leads to multifunctional composite materials with different and predictable mechanical and insulation properties.

  20. Water level measurement system in reactor pressure vessel of BWR and hydrogen concentration monitoring system for severe accident

    International Nuclear Information System (INIS)

    Kuroda, Hidehiko; Okazaki, Koki; Shiraishi, Fujio; Kenjyo, Hiroaki; Isoda, Koichiro

    2013-01-01

    TEPCO's Fukushima Daiichi Nuclear Power Station Accident caused severe accident to lose functions of many instrumentation systems. As a result, many important plant parameters couldn't be monitored. In order to monitor plant parameters in the case of severe accident, new instrumentation systems available in the severe conditions are being developed. Water level in reactor pressure vessel and hydrogen concentration in primary containment vessel are one of the most important parameters. Performance test results about water level measurement sensor and hydrogen sensor in severe environmental conditions are described. (author)