WorldWideScience

Sample records for tip rub testing

  1. Simulated Tip Rub Testing of Low-Density Metal Foam

    Science.gov (United States)

    Bowman, Cheryl L.; Jones, Michael G.

    2009-01-01

    Preliminary acoustic studies have indicated that low-density, open-cell, metal foams may be suitable acoustic liner material for noise suppression in high by-pass engines. Metal foam response under simulated tip rub conditions was studied to assess whether its durability would be sufficient for the foam to serve both as a rub strip above the rotor as well as an acoustic treatment. Samples represented four metal alloys, nominal cell dimensions ranging from 60 to 120 cells per inch (cpi), and relative densities ranging from 3.4 to 10 percent. The resulting rubbed surfaces were relatively smooth and the open cell structure of the foam was not adversely affected. Sample relative density appeared to have significant influence on the forces induced by the rub event. Acoustic responses of various surface preparations were measured using a normal incidence tube. The results of this study indicate that the foam s open-cell structure was retained after rubbing and that the acoustic absorption spectra variation was minimal.

  2. Advanced ceramic material for high temperature turbine tip seals

    Science.gov (United States)

    Solomon, N. G.; Vogan, J. W.

    1978-01-01

    Ceramic material systems are being considered for potential use as turbine blade tip gas path seals at temperatures up to 1370 1/4 C. Silicon carbide and silicon nitride structures were selected for study since an initial analysis of the problem gave these materials the greatest potential for development into a successful materials system. Segments of silicon nitride and silicon carbide materials over a range of densities, processed by various methods, a honeycomb structure of silicon nitride and ceramic blade tip inserts fabricated from both materials by hot pressing were tested singly and in combination. The evaluations included wear under simulated engine blade tip rub conditions, thermal stability, impact resistance, machinability, hot gas erosion and feasibility of fabrication into engine components. The silicon nitride honeycomb and low-density silicon carbide using a selected grain size distribution gave the most promising results as rub-tolerant shroud liners. Ceramic blade tip inserts made from hot-pressed silicon nitride gave excellent test results. Their behavior closely simulated metal tips. Wear was similar to that of metals but reduced by a factor of six.

  3. Numerical investigations on axial and radial blade rubs in turbo-machinery

    Science.gov (United States)

    Abdelrhman, Ahmed M.; Tang, Eric Sang Sung; Salman Leong, M.; Al-Qrimli, Haidar F.; Rajamohan, G.

    2017-07-01

    In the recent years, the clearance between the rotor blades and stator/casing had been getting smaller and smaller prior improving the aerodynamic efficiency of the turbomachines as demand in the engineering field. Due to the clearance reduction between the blade tip and the rotor casing and between rotor blades and stator blades, axial and radial blade rubbing could be occurred, especially at high speed resulting into complex nonlinear vibrations. The primary aim of this study is to address the blade axial rubbing phenomenon using numerical analysis of rotor system. A comparison between rubbing caused impacts of axial and radial blade rubbing and rubbing forces are also aims of this study. Tow rotor models (rotor-stator and rotor casing models) has been designed and sketched using SOILDSWORKS software. ANSYS software has been used for the simulation and the numerical analysis. The rubbing conditions were simulated at speed range of 1000rpm, 1500rpm and 2000rpm. Analysis results for axial blade rubbing showed the appearance of blade passing frequency and its multiple frequencies (lx, 2x 3x etc.) and these frequencies will more excited with increasing the rotational speed. Also, it has been observed that when the rotating speed increased, the rubbing force and the harmonics frequencies in x, y and z-direction become higher and severe. The comparison study showed that axial blade rub is more dangerous and would generate a higher vibration impacts and higher blade rubbing force than radial blade rub.

  4. Modeling the rubbing contact in honeycomb seals

    Science.gov (United States)

    Fischer, Tim; Welzenbach, Sarah; Meier, Felix; Werner, Ewald; kyzy, Sonun Ulan; Munz, Oliver

    2018-03-01

    Metallic honeycomb labyrinth seals are commonly used as sealing systems in gas turbine engines. Because of their capability to withstand high thermo-mechanical loads and oxidation, polycrystalline nickel-based superalloys, such as Hastelloy X and Haynes 214, are used as sealing material. In addition, these materials must exhibit a tolerance against rubbing between the rotating part and the stationary seal component. The tolerance of the sealing material against rubbing preserves the integrity of the rotating part. In this article, the rubbing behavior at the rotor-stator interface is considered numerically. A simulation model is incorporated into the commercial finite element code ABAQUS/explicit and is utilized to simulate a simplified rubbing process. A user-defined interaction routine between the contact surfaces accounts for the thermal and mechanical interfacial behavior. Furthermore, an elasto-plastic constitutive material law captures the extreme temperature conditions and the damage behavior of the alloys. To validate the model, representative quantities of the rubbing process are determined and compared with experimental data from the literature. The simulation results correctly reproduce the observations made on a test rig with a reference stainless steel material (AISI 304). A parametric study using the nickel-based superalloys reveals a clear dependency of the rubbing behavior on the sliding and incursion velocity. Compared to each other, the two superalloys studied exhibit a different rubbing behavior.

  5. Tips on Blood Testing

    Science.gov (United States)

    ... Test Pain, Discomfort and Anxiety Tips to Help Children through Their Medical Tests Tips to Help the Elderly through Their Medical Tests Find Us On Social Media: Facebook Twitter Google Plus Footer Menu Home About ...

  6. Prevalence of muzzle-rubbing and hand-rubbing behavior in wild chimpanzees in Mahale Mountains National Park, Tanzania.

    Science.gov (United States)

    Corp, Nadia; Hayaki, Hitoshige; Matsusaka, Takahisa; Fujita, Shiho; Hosaka, Kazuhiko; Kutsukake, Nobuyuki; Nakamura, Michio; Nakamura, Miho; Nishie, Hitonaru; Shimada, Masaki; Zamma, Koichiro; Wallauer, William; Nishida, Toshisada

    2009-04-01

    In 1998, four chimpanzees in the Mahale Mountains National Park, Tanzania, were observed wiping their mouths with non-detached leaves or stalks of grass, or rubbing their mouths with a tree trunk or branch, especially while eating lemons. The number of mouth-wiping/rubbing individuals increased to 18 in 1999. By 2005, 29 chimpanzees were documented wiping/rubbing their muzzles in this way. Although it is difficult to determine whether the chimpanzees acquired this behavior as a result of trial and error or social learning, the fact that chimpanzees at other sites perform this behavior with detached leaves or leafy twigs much more often than with intact items suggests the possibility that cleaning with intact plant parts at Mahale spread via social learning.

  7. Dynamic Characteristics and Experimental Research of Dual-Rotor System with Rub-Impact Fault

    Directory of Open Access Journals (Sweden)

    Hongzhi Xu

    2016-01-01

    Full Text Available Rub-impact fault model for dual-rotor system was further developed, in which rubbing board is regarded as elastic sheet. Sheet elastic deformation, contact penetration, and elastic damping support during rubbing of sheet and wheel disk were considered. Collision force and friction were calculated by utilizing Hertz contact theory and Coulomb model and introducing nonlinear spring damping model and friction coefficient. Then kinetic differential equations of rub-impact under dry rubbing condition were established. Based on one-dimensional finite element model of dual-rotor system, dynamic transient response of overall structure under rub-impact existing between rotor wheel and sheet was obtained. Meanwhile, fault dynamic characteristics and impact of rubbing clearance on rotor vibration were analyzed. The results show that, during the process of rub-impact, the spectrums of rotor vibration are complicated and multiple combined frequency components of inner and outer rotor fundamental frequencies are typical characteristic of rub-impact fault for dual-rotor system. It also can be seen from rotor vibration response that the rubbing rotor’s fundamental frequency is modulated by normal rotor double frequency.

  8. Hand Hygiene With Alcohol-Based Hand Rub: How Long Is Long Enough?

    Science.gov (United States)

    Pires, Daniela; Soule, Hervé; Bellissimo-Rodrigues, Fernando; Gayet-Ageron, Angèle; Pittet, Didier

    2017-05-01

    BACKGROUND Hand hygiene is the core element of infection prevention and control. The optimal hand-hygiene gesture, however, remains poorly defined. OBJECTIVE We aimed to evaluate the influence of hand-rubbing duration on the reduction of bacterial counts on the hands of healthcare personnel (HCP). METHODS We performed an experimental study based on the European Norm 1500. Hand rubbing was performed for 10, 15, 20, 30, 45, or 60 seconds, according to the WHO technique using 3 mL alcohol-based hand rub. Hand contamination with E. coli ATCC 10536 was followed by hand rubbing and sampling. A generalized linear mixed model with a random effect on the subject adjusted for hand size and gender was used to analyze the reduction in bacterial counts after each hand-rubbing action. In addition, hand-rubbing durations of 15 and 30 seconds were compared to assert non-inferiority (0.6 log10). RESULTS In total, 32 HCP performed 123 trials. All durations of hand rubbing led to significant reductions in bacterial counts (Phand rubbing were not significantly different from those obtained after 30 seconds. The mean bacterial reduction after 15 seconds of hand rubbing was 0.11 log10 lower (95% CI, -0.46 to 0.24) than after 30 seconds, demonstrating non-inferiority. CONCLUSIONS Hand rubbing for 15 seconds was not inferior to 30 seconds in reducing bacterial counts on hands under the described experimental conditions. There was no gain in reducing bacterial counts from hand rubbing longer than 30 seconds. Further studies are needed to assess the clinical significance of our findings. Infect Control Hosp Epidemiol 2017;38:547-552.

  9. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    Science.gov (United States)

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  10. Resultado de los embarazos complicados con rubéola, 1990-1997

    Directory of Open Access Journals (Sweden)

    Figueroa-Damián Ricardo

    1999-01-01

    Full Text Available OBJETIVO. Describir la experiencia del manejo de embarazadas con rubéola, evaluando el resultado perinatal. MATERIAL Y MÉTODOS. Del 1 de enero de 1990 al 31 de octubre de 1997 se incluyeron 67 embarazadas con diagnóstico de rubéola, corroborada con la determinación de anticuerpos séricos IgM. Se dio seguimiento hasta la resolución del embarazo en 66 de estas mujeres: en cuatro se realizó un aborto electivo y una tuvo un embarazo molar. En 61 pacientes se pudo evaluar el efecto de la rubéola sobre el producto y la gestación. A los productos con determinación positiva de IgM contra rubéola se les realizó ecocardiograma, estudio oftalmológico y potenciales provocados auditivos del tallo cerebral (PPATC. RESULTADOS. El promedio de edad de las embarazadas fue de 24.7±5.5 años; 28 pacientes cursaban su primer embarazo. Ninguna de las embarazadas presentó alguna complicación del episodio de rubéola. En 35 casos (52.2% la infección viral se presentó durante el primer trimestre de gestación; en 23 (34.5% sucedió durante el segundo trimestre, y en nueve (13.3% ocurrió en el último trimestre. De los casos de infección materna durante el primer trimestre gestacional, 71% de los productos se infectaron y 51.6% desarrollaron un síndrome de rubéola congénita. Las manifestaciones de rubéola congénita más frecuentes fueron prematurez, bajo peso al nacimiento y alteración de los PPATC. CONCLUSIONES. En México la rubéola continúa causando daño fetal, de tal manera que es necesario establecer medidas de prevención, como la vacunación universal, para evitar la infección por rubéola.

  11. Single treatment with ethanol hand rub is ineffective against human rhinovirus--hand washing with soap and water removes the virus efficiently.

    Science.gov (United States)

    Savolainen-Kopra, Carita; Korpela, Terttu; Simonen-Tikka, Marja-Leena; Amiryousefi, Ali; Ziegler, Thedi; Roivainen, Merja; Hovi, Tapani

    2012-03-01

    Ethanol-containing hand rubs are used frequently as a substitute for hand washing with water and soap. However, not all viruses are inactivated by a short term rubbing with alcohol. The capacity of a single round of instructed and controlled hand cleaning with water and soap or ethanol-containing hand rub, respectively, was tested for removal of human rhinovirus administered onto the skin of healthy volunteers on the back of the hands. Hand washing with soap and water appeared to be much more efficient for removing rhinoviruses from skin than rubbing hands with an ethanol-containing disinfectant. After washing with soap and water the virus was detected in 3/9 (33.3%) test persons from the left hand and 1/9 (11.1%) cases from the right hand, whereas the virus was detected invariably by real-time RT-PCR from both hands after cleaning with alcohol hand rub (P-value soap can clean efficiently hands contaminated with the virus responsible for an extensive share of common cold episodes. Copyright © 2012 Wiley Periodicals, Inc.

  12. Structure and state of repeatedly rubbed pure iron

    Energy Technology Data Exchange (ETDEWEB)

    Furuichi, Hiroshi [Dept. of Mechanical System Engineering, Yamanashi Univ., Kofu (Japan); Nakamura, Shoichiro [Dept. of Mechanical System Engineering, Yamanashi Univ., Kofu (Japan); Xuan Junsong [Nippo Precision Ltd., Nirasaki (Japan); Yamazaki, Kunihiro [Dept. of Mechanical System Engineering, Yamanashi Univ., Kofu (Japan)

    1995-05-01

    Pure iron was repeatedly rubbed under special conditions. The highest and the average hardness near the friction surface were 1431 HV and 1146 HV, respectively. Diffraction patterns near the friction surface showed a broad hexagonal ring corresponding to the (002) plane of {epsilon}-iron (hcp), although the other rings are from {alpha}-iron. Extremely fine imperfectly defined regions were observed from the area of this diffraction pattern. Another diffraction patterns showed an extremely diffuse and faint halo ring indicating an amorphous state, whose average atomic distance equals one of the interplanar spacing of the basal plane of {epsilon}-iron. This amorphous state differs from that by obtained rapid quenching. These results suggest that a structure with only the basal plane of {epsilon}-iron appeared during the rubbing and further destruction resulted in the amorphous state. Extremely high pressure may arise during rubbing: {epsilon}-iron forms above 13 GPa at room temperature and the basal plane consists of the shortest atomic distance of iron. In the latter pattern, a spot arrangement indicating a structure ordered only in one or two directions was observed. Rows of pits and cracks connecting them were observed, on the side surface near the rubbed surface, which shows crack formation during sliding contact fatigue. (orig.)

  13. The hammer QSD-quick stop device for high speed machining and rubbing

    Science.gov (United States)

    Black, J. T.; James, C. R.

    1980-01-01

    A quick stop device (QSD) was designed for use in orthogonal machining and rubbing experiments. QSD's are used to obtain chip root samples that are representative of the deformation taking place during dynamic (actual) cutting conditions. These 'frozen' specimens are helpful in examining the plastic deformation that occurs in the regions of compression and shear which form the chip; the secondary shear at the tool-chip interface; and the nose ploughing/flank rubbing action which operates on the newly machined surface. The Hammer QSD employs a shear pin mechanism, broken by a flying hammer, which is traveling at the same velocity as the workpiece. The device has been successfully tested up to 6000 sfpm (30.48 m/sec).

  14. Behaviour modification in the management of chronic habits of abnormal eye rubbing.

    Science.gov (United States)

    McMonnies, Charles W

    2009-04-01

    To describe how and why many keratoconus patients do not comply with strong advice to control chronic habits of abnormal rubbing. To outline a behaviour modification approach for controlling chronic habits of abnormal rubbing. Common reasons for chronic habits of abnormal rubbing have been reviewed as a basis for specifying a behavioural modification approach to habit reversal. The methods described are organized into the classic behavioural modification structure of: (1) habit awareness, (2) competing responses, (3) development of motivation, and (4) social support. This structure is supported by the application of social influence principles to achieve optimum compliance. The use of take-home written information in the form of an Abnormal Rubbing Guide is the basis for the development of motivation. Family social support is based upon a widening of the responsibility for avoiding eye rubbing to all family members. Some patients will need minimal application of these principles with patient education being sufficient intervention to achieve habit reversal. For patients with strong provocation to rubbing and/or by having a well established rubbing habit, a greater exposure to the habit reversal program described is indicated. Successful habit reversal may slow the rate of ectasia progression. Prophylactic application of the methods described for patients who are at risk for developing keratoconus, or post-laser assisted in situ keratomileusis keratectasia, may show that some forms of keratectasia are preventable.

  15. The Role of RUB (related to ubiquitin) Family of Proteins in the Hormone Response. Final Report.

    Energy Technology Data Exchange (ETDEWEB)

    Callis, Judy [Univ. of California, Davis, CA (United States). Dept. of Molecular and Cellular Biology

    2013-03-22

    The Rub pathway is a conserved protein modification pathway. RUB (called Rubp1 in budding yeast, Nedd8 in animals and RUB in plants) is a ubiquitin-like 76-amino acid protein. It covalently attaches to protein using an enzymatic machinery analogous to the enzymes that attach ubiquitin to its substrate proteins. However, the nature of the complement of Rub-modified proteins in organisms was not clear. From bioinformatics analyses, one can identify a Rub activating enzymes and Rub conjugating enzymes. However, in many cases, their biochemical properties were not described. In DOE-funded work, we made major advances in our understanding of the Rub pathway in yeast and plants, work that is applicable to other organisms as well. There is a multi-subunit enzyme called SCF in all eukaryotes. The SCF consists of several subunits that serve as a scaffold (the cullin, SKP and RBX subunits) and one subunit that interacts with the substrate. This cullin protein (called Cdc53p in yeast and CULLIN 1 in plants and animals) was a known Rub target. In this work, we identified additional Rub targets in yeast as the other cullin-like proteins Cul3p and Rtt101p. Additionally we described the conservation of the Rub pathway because plant RUB1 can conjugated to yeast Cdc53p- in yeast. In the model plant Arabidopsis thaliana, we characterized the Rub activating enzymes and showed that they are not biochemically equivalent. We also showed that the Rub pathway is essential in plants and characterized plants with reduced levels of rub proteins. These plants are affected in multiple developmental processes. We discovered that they over-produce ethylene as dark-grown seedlings. We characterized a mutant allele of CULLIN1 in Arabidopsis with impaired interaction with RBX and showed that it is unstable in vivo. We used our knowledge of monitoring protein degradation to map the degradation determinants in a plant transcription factor. Finally, we took a mass spectrometric approach to identify

  16. The Dynamics of Rotor with Rubbing

    Directory of Open Access Journals (Sweden)

    Jerzy T. Sawicki

    1999-01-01

    characteristics of rub-induced rotor response, initial conditions, as well as appropriate ranges of system parameters. Of special interest are the changes in the apparent nonlinearity of the system dynamics as rubs are induced at different rotor speeds. In particular, starting with 2nd order sub/superharmonics, which are symptomatic of quadratic nonlinearity, progressively higher order polynomial behavior is excited, i.e., cubic, giving rise to 3rd order sub/superharmonics. As the speed is transitioned between such apparent nonlinearities, chaotic like behavior is induced because of the lack of whole or rational tone tuning between the apparent system frequency and the external source noise. The cause of such behavior will be discussed in detail along with the results of several parametric studies.

  17. Thermomechanical Behavior of Rotor with Rubbing

    Directory of Open Access Journals (Sweden)

    Jerzy T. Sawicki

    2003-01-01

    Full Text Available This article presents an analytical study of the dynamics and stability of rotors subjected to rubbing due to contact with seals, taking account of associated thermal effects. The seal interaction force acting on the shaft gives rise to a friction force, which is a source of heating and can induce so-called spiral vibrations. A mathematical model that has been developed couples the heat-conduction equation with the equations for motion of the rotor. Numerical simulations have been conducted that show the thermomechanical behavior of the rotor at various operating conditions. A procedure for analyzing the stability of multibearing rotors based on the system eigenvalue analysis and the state-space approach has been proposed. Finally, the experimental data related to full annular rub have been presented.

  18. A Method to Transit the Rotor-to-Stator Rubbing to Normal Motion Using the Phase Characteristic

    Directory of Open Access Journals (Sweden)

    Jieqiong Xu

    2014-01-01

    Full Text Available A method is proposed to transit the rotor-to-stator rubbing to no-rub motion through active auxiliary bearing. The key point of this technique is to express the attractive domain of no-rub motion based on the phase characteristic and to represent the desired status. The feedback actuation is applied by an active auxiliary bearing to drive the rotor approaching the desired status. After that, the control actuation is turned off. Although the desired status is still in rubbing, it is in the attractive domain of no-rub motion, and the response of the rotor is automatically attracted to no-rub motion.

  19. Influence of rub-in technique on required application time and hand coverage in hygienic hand disinfection

    Directory of Open Access Journals (Sweden)

    Feil Yvonne

    2008-10-01

    Full Text Available Abstract Background Recent data indicate that full efficacy of a hand rub preparation for hygienic hand disinfection can be achieved within 15 seconds (s. However, the efficacy test used for the European Norm (EN 1500 samples only the fingertips. Therefore, we investigated hand coverage using sixteen different application variations. The hand rub was supplemented with a fluorescent dye, and hands were assessed under UV light by a blind test, before and after application. Fifteen non-healthcare workers were used as subjects for each application variation apart from one test which was done with a group of twenty healthcare workers. All tests apart from the reference procedure were performed using 3 mL of hand rub. The EN 1500 reference procedure, which consists of 6 specific rub-in steps performed twice with an aliquot of 3 ml each time, served as a control. In one part of this study, each of the six steps was performed from one to five times before proceeding to the next step. In another part of the study, the entire sequence of six steps was performed from one to five times. Finally, all subjects were instructed to cover both hands completely, irrespective of any specific steps ("responsible application". Each rub-in technique was evaluated for untreated skin areas. Results The reference procedure lasted on average 75 s and resulted in 53% of subjects with at least one untreated area on the hands. Five repetitions of the rub-in steps lasted on average 37 s with 67% of subjects having incompletely treated hands. One repetition lasted on average 17 s, and all subjects had at least one untreated area. Repeating the sequence of steps lasted longer, but did not yield a better result. "Responsible application" was quite fast, lasting 25 s among non-healthcare worker subjects and 28 s among healthcare workers. It was also effective, with 53% and 55% of hands being incompletely treated. New techniques were as fast and effective as "responsible

  20. Head rubbing and licking reinforce social bonds in a group of captive African lions, Panthera leo.

    Science.gov (United States)

    Matoba, Tomoyuki; Kutsukake, Nobuyuki; Hasegawa, Toshikazu

    2013-01-01

    Many social animals have a species-specific repertoire of affiliative behaviours that characterise individualised relationships within a group. To date, however, quantitative studies on intragroup affiliative behaviours in social carnivores have been limited. Here, we investigated the social functions of the two most commonly observed affiliative behaviours in captive African lions (Panthera leo): head rubbing and licking. We conducted behavioural observations on a captive group of lions composed of 7 males and 14 females, and tested hypotheses regarding three social functions: tension reduction, social bonding, and social status expression. Disproportionately frequent male-male and female-to-male head rubbing was observed, while more than 95% of all licking interactions occurred in female-female dyads. In accordance with the social bond hypothesis, and in disagreement with the social status expression hypothesis, both head rubbing and licking interactions were reciprocal. After controlling for spatial association, the dyadic frequency of head rubbing was negatively correlated with age difference while licking was positively correlated with relatedness. Group reunion after daily separation did not affect the frequencies of the affiliative behaviours, which was in disagreement with the predictions from the tension reduction hypothesis. These results support the social bond hypothesis for the functions of head rubbing and licking. Different patterns of affiliative behaviour between the sexes may reflect differences in the relationship quality in each sex or the differential predisposition to licking due to its original function in offspring care.

  1. Head rubbing and licking reinforce social bonds in a group of captive African lions, Panthera leo.

    Directory of Open Access Journals (Sweden)

    Tomoyuki Matoba

    Full Text Available Many social animals have a species-specific repertoire of affiliative behaviours that characterise individualised relationships within a group. To date, however, quantitative studies on intragroup affiliative behaviours in social carnivores have been limited. Here, we investigated the social functions of the two most commonly observed affiliative behaviours in captive African lions (Panthera leo: head rubbing and licking. We conducted behavioural observations on a captive group of lions composed of 7 males and 14 females, and tested hypotheses regarding three social functions: tension reduction, social bonding, and social status expression. Disproportionately frequent male-male and female-to-male head rubbing was observed, while more than 95% of all licking interactions occurred in female-female dyads. In accordance with the social bond hypothesis, and in disagreement with the social status expression hypothesis, both head rubbing and licking interactions were reciprocal. After controlling for spatial association, the dyadic frequency of head rubbing was negatively correlated with age difference while licking was positively correlated with relatedness. Group reunion after daily separation did not affect the frequencies of the affiliative behaviours, which was in disagreement with the predictions from the tension reduction hypothesis. These results support the social bond hypothesis for the functions of head rubbing and licking. Different patterns of affiliative behaviour between the sexes may reflect differences in the relationship quality in each sex or the differential predisposition to licking due to its original function in offspring care.

  2. Tips to Help Children through Their Medical Tests

    Science.gov (United States)

    ... Resources For Health Professionals Subscribe Search Tips to Help Children through Their Medical Tests Send Us Your ... them through the procedure. A caring grownup can help the child cope with any physical pain or ...

  3. Encouraging energy conservation in multifamily housing: RUBS and other methods of allocating energy costs to residents

    Energy Technology Data Exchange (ETDEWEB)

    McClelland, L

    1980-10-01

    Methods of encouraging energy conservation in multifamily housing by allocating energy costs to residents are discussed; specifically, methods appropriate for use in master metered buildings without equipment to monitor energy consumption in individual apartments are examined. Several devices available for monitoring individual energy consumption are also discussed plus methods of comparing the energy savings and cost effectiveness of monitoring devices with those of other means of promoting conservation. Specific information in Volume I includes a comparison study on energy use in master and individually metered buildings; types of appropriate conservation programs for master metered buildings; a description of the Resident Utility Billing System (RUBS); energy savings associated with RUBS; Resident reactions to RUBS; cost effectiveness of RUBS for property owners; potential abuses, factors limiting widespread use, and legal status of RUBS. Part I of Volume II contains a cost allocation decision guide and Part II in Volume II presents the RUBS Operations Manual. Pertinent appendices to some chapters are attached. (MCW)

  4. Unilateral Keratoconus after Chronic Eye Rubbing by the Nondominant Hand

    Directory of Open Access Journals (Sweden)

    Nathalie Bral

    2017-12-01

    Full Text Available Introduction: To report the development of unilateral keratoconus in a healthy male after persistent unilateral eye rubbing by the nondominant hand which was not needed for professional activities. Methods: Observational case report. Results: A 60-year-old male was first seen in our clinic due to decreased vision in his left eye. Slit-lamp biomicroscopy of the left eye revealed Vogt’s striae, stromal thinning, and a stromal scar. Corneal topography showed a stage 4 keratoconus. Clinical examination and corneal topography of the right eye were normal. Medical history revealed a habit of chronic eye rubbing only in the left eye because of the right hand being occupied for professional needs. During follow-up of 5 years, Scheimpflug images of the right eye stayed normal while the left eye showed a stable cone. Discussion: This case report supports the hypothesis of mechanical fatigue of the cornea due to repetitive shear stress on the surface caused by eye-rubbing.

  5. [Disinfection efficacy of hand hygiene based on chlorhexidine gluconate content and usage of alcohol-based hand-rubbing solution].

    Science.gov (United States)

    Tanaka, Ippei; Watanabe, Kiyoshi; Nakaminami, Hidemasa; Azuma, Chihiro; Noguchi, Norihisa

    2014-01-01

    Recently, the procedure for surgical hand hygiene has been switching to a two-stage method and hand-rubbing method from the traditional hand-scrubbing method. Both the two-stage and hand-rubbing methods use alcohol-based hand-rubbing after hand washing. The former requires 5 min of antiseptic hand washing, and the latter 1 min of nonantiseptic hand washing. For a prolonged bactericidal effect in terms of surgical hand hygiene, chlorhexidine gluconate (CHG) has been noted due to its residual activity. However, no detailed study comparing the disinfection efficacy and prolonged effects according to different contents of CHG and the usage of alcohol-based hand-rubbing has been conducted. The glove juice method is able to evaluate disinfection efficacy and prolonged effects of the disinfectants more accurately because it can collect not only transitory bacteria but also normal inhabitants on hands. In the present study, we examined the disinfection efficacy and prolonged effects on alcohol-based hand-rubbing containing CHG by six hand-rubbing methods and three two-stage methods using the glove juice method. In both methods, 3 mL (one pump dispenser push volume) alcohol-based hand-rubbing solution containing 1% (w/v) CHG showed the highest disinfection efficacy and prolonged effects, and no significant difference was found between the hand-rubbing and two-stage methods. In the two methods of hand hygiene, the hand-rubbing method was able to save time and cost. Therefore, the data strongly suggest that the hand-rubbing method using a one pump dispenser push volume of alcohol-based hand-rubbing solution containing 1% (w/v) CHG is suitable for surgical hand hygiene.

  6. Fur-rubbing with Piper leaves in the San Martín titi monkey, Callicebus oenanthe

    Directory of Open Access Journals (Sweden)

    R. Huashuayo-Llamocca

    2017-06-01

    Full Text Available We report observations on fur-rubbing with leaves from Piper aduncum by a San Martín titi monkey, Callicebus oenanthe. Fur-rubbing occurred during the transition from the dry to the rainy season in a titi monkey group living in a forest fragment in the Moyobamba region of Peru. Since Piper leaves include very potent compounds that may affect ectoparasites, we tentatively interpret the observed fur-rubbing as self-medication.

  7. Coefficients of sliding friction of single crystals of high explosives under different rubbing conditions

    International Nuclear Information System (INIS)

    Wu, Y Q; Chaudhri, M Munawar

    2013-01-01

    The coefficients of sliding friction of single crystals of commonly used high explosives pentaerythritol tetranitrate (PETN), cyclotrimethylene trinitramine (RDX) and beta-cyclotetramethylene tetranitramine (β-HMX) under several rubbing configurations and at a relative sliding speed of 0.22 mm s -1 were measured. The sliding configurations were (1) crystal-polished steel pairs, (2) like-crystal pairs and (3) unlike-crystal pairs. For every rubbing configuration the friction force showed oscillations, which are thought to be caused by the formation and shearing of the adhesive junctions formed at the surface of the rubbing crystals. This shearing of the adhesive junctions led to the formation of microscopic and sub-microscopic particles, which were confirmed by an environmental scanning electron microscope study. For every rubbing configuration and for relatively high normal loads pressing the rubbing crystals together, the coefficient of friction was generally in the range 0.2-0.25 and it has been concluded that the coefficient of friction is controlled by the adhesion with almost negligible contribution from the ploughing component. From a knowledge of the coefficient of friction and the uniaxial yield stress values of single crystals of RDX and β-HMX, the shear strength of these crystals were determined to be ∼13.4 MPa and ∼16.8 MPa, respectively.

  8. Hand hygiene with alcohol hand rub and gloves reduces the incidence of late onset sepsis in preterm neonates.

    Science.gov (United States)

    Janota, Jan; Šebková, Sylva; Višňovská, Magda; Kudláčková, Jana; Hamplová, Drahomíra; Zach, Jiří

    2014-10-01

    To assess the impact of a hand hygiene protocol, using hand washing, alcohol hand rub and gloves when caring for preterm infants born after 31 weeks of gestation, on the incidence of neonatal late onset sepsis (LOS). All babies delivered between 32 + 0 and 36 + 6 weeks gestation and admitted to the neonatal intensive care unit during a 14-month period were included. We followed a hand hygiene protocol with hand washing and alcohol hand rub (hand rub period) for the first 7 months and a protocol of hand washing, alcohol hand rub and gloves (gloves period) for the second 7 months. The hand rub and gloves groups consisted of 111 and 89 patients, respectively. Five patients were diagnosed with a total of six episodes of LOS in the hand rub group, and the incidence of LOS during the hand rub period was 2.99/1000 hospital days and 54.1/1000 admissions. There were no patients diagnosed with LOS during the gloves period (significant decrease, p = 0.028). Using a hand hygiene protocol with hand washing, hand rub and gloves significantly reduced the incidence of LOS in preterm newborns, and the results suggest that it may produce a sustained improvement in the infection rate. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  9. Possible multigap type-I superconductivity in the layered boride RuB2

    Science.gov (United States)

    Singh, Jaskaran; Jayaraj, Anooja; Srivastava, D.; Gayen, S.; Thamizhavel, A.; Singh, Yogesh

    2018-02-01

    The structure of the layered transition-metal borides A B2 (A =Os,Ru ) is built up by alternating T and B layers with the B layers forming a puckered honeycomb. Here we report superconducting properties of RuB2 with a Tc≈1.5 K using measurements of the magnetic susceptibility versus temperature T , magnetization M versus magnetic field H , resistivity versus T , and heat capacity versus T at various H . We observe a reduced heat capacity anomaly at Tc given by Δ C /γ Tc≈1.1 suggesting multigap superconductivity. Strong support for this is obtained by the successful fitting of the electronic specific heat data to a two-gap model with gap values Δ1/kBTc≈1.88 and Δ2/kBTc≈1.13 . Additionally, M versus H measurements reveal a behavior consistent with type-I superconductivity. This is confirmed by comparing the experimental critical field ≈122 Oe obtained from extrapolation to T =0 of the H -T phase diagram, with an estimate of the T =0 thermodynamic critical field ≈114 Oe. Additionally, the Ginzburg-Landau parameter was estimated to be κ ≈0.1 -0.66 . These results strongly suggest multigap type-I superconductivity in RuB2. We also calculate the band structure and obtain the Fermi surface for RuB2. The Fermi surface consists of one quasi-two-dimensional sheet and two concentric ellipsoidal sheets very similar to OsB2. An additional small fourth sheet is also found for RuB2. RuB2 could thus be an example of a multigap type-I superconductor.

  10. Dynamic characteristics of dual-rotor system with coupling faults of misalignment and rub-impact

    Directory of Open Access Journals (Sweden)

    Huang Zhiwei

    2017-01-01

    Full Text Available According to fault problems of the rotor system local rubbing caused by mass eccentricity, a dynamic model for the dual-rotor system with coupling faults of misalignment and rub-impact was established. The dynamic behaviours of this system were investigated by using numerical integral method, as parallel and angular misalignment varied. Various nonlinear phenomena compressing periodic, three-periodic and quasi-periodic motions are observed. The results reveal that the process of the rotor rub-impact is extremely complex and has some frequencies with large amplitude, especially at the 1/3X component. Meanwhile, quasi-periodic regions exhibit different configurations of attractors and the phenomenon of beat vibration.

  11. Investigation of plastic zones near SCC tips in a pipeline after hydrostatic testing

    International Nuclear Information System (INIS)

    Li Jian; Elboujdaini, M.; Gao, M.; Revie, R.W.

    2008-01-01

    Stress corrosion cracking (SCC) is an important failure mechanism for oil and gas pipelines. In the past, hydrostatic testing has been frequently used to assess and mitigate stress corrosion cracking. It is commonly agreed that an effective hydrostatic test not only eliminates critical crack-like flaws, but also blunts the sub-critical crack tip thereby suppressing further SCC propagation. However, little study has been done on the plastic deformation that results from the high stress intensity at the crack tip due to hydrostatic testing pressure and its possible role in subsequent SCC propagation. In this study, microstructural details were examined of an API 5L X52 SCC-containing pipe removed from field service. Plastic deformation generated by the hydrostatic testing pressure was revealed by using high-resolution imaging of a focused ion beam (FIB) microscope. The existence of the microscopic plastic zones around some crack tips suggests that caution should be taken when setting up pipeline hydrostatic tests

  12. Investigation of plastic zones near SCC tips in a pipeline after hydrostatic testing

    Energy Technology Data Exchange (ETDEWEB)

    Li Jian [Materials Technology Laboratory, Natural Resources Canada, 568 Booth Street, Ottawa, Ont., K1A 0G1 (Canada)], E-mail: jili@nrcan.gc.ca; Elboujdaini, M [Materials Technology Laboratory, Natural Resources Canada, 568 Booth Street, Ottawa, Ont., K1A 0G1 (Canada); Gao, M [Blade Energy Partners, 16225 Park Ten Place, Suite 450, Houston, TX 77084 (United States); Revie, R W [Materials Technology Laboratory, Natural Resources Canada, 568 Booth Street, Ottawa, Ont., K1A 0G1 (Canada)

    2008-07-15

    Stress corrosion cracking (SCC) is an important failure mechanism for oil and gas pipelines. In the past, hydrostatic testing has been frequently used to assess and mitigate stress corrosion cracking. It is commonly agreed that an effective hydrostatic test not only eliminates critical crack-like flaws, but also blunts the sub-critical crack tip thereby suppressing further SCC propagation. However, little study has been done on the plastic deformation that results from the high stress intensity at the crack tip due to hydrostatic testing pressure and its possible role in subsequent SCC propagation. In this study, microstructural details were examined of an API 5L X52 SCC-containing pipe removed from field service. Plastic deformation generated by the hydrostatic testing pressure was revealed by using high-resolution imaging of a focused ion beam (FIB) microscope. The existence of the microscopic plastic zones around some crack tips suggests that caution should be taken when setting up pipeline hydrostatic tests.

  13. Electronic and elastic properties of new semiconducting oP12-type RuB2 and OsB2

    International Nuclear Information System (INIS)

    Hao Xianfeng; Xu Yuanhui; Gao Faming

    2011-01-01

    Using first-principles total energy calculations we investigate the structural, elastic and electronic properties of new hypothetical oP 12 -type phase RuB 2 and OsB 2 . The calculations indicate that the oP 12 -type phase RuB 2 and OsB 2 are thermodynamically and mechanically stable. Remarkably, the new phases RuB 2 and OsB 2 are predicted to be semiconductors, and the appearance of band gaps is ascribed to the enhanced B-B covalent hybridization. Compared to metallic oP 6 -type RuB 2 and OsB 2 phases, the new phases possess similar mechanical properties and hardness. The combination of the probability of tunable electronic properties, strong stiffness and high hardness make RuB 2 and OsB 2 attractive and interesting for advanced applications.

  14. Opportunity's 'Rub al Khali' Panorama

    Science.gov (United States)

    2005-01-01

    [figure removed for brevity, see original site] Click on the image for Opportunity's 'Rub al Khali' Panorama (QTVR) This panoramic image, dubbed 'Rub al Khali,' was acquired by NASA's Mars Exploration Rover Opportunity on the plains of Meridiani during the period from the rover's 456th to 464th sols on Mars (May 6 to May 14, 2005). Opportunity was about 2 kilometers (1.2 miles) south of 'Endurance Crater' at a place known informally as 'Purgatory Dune.' The rover was stuck in the dune's deep fine sand for more than a month. 'Rub al Khali' (Arabic translation: 'the empty quarter') was chosen as the name for this panorama because it is the name of a similarly barren, desolate part of the Saudi Arabian desert on Earth. The view spans 360 degrees. It consists of images obtained in 97 individual pointings of the panoramic camera. The camera took images with five camera filters at each pointing. This 22,780-by-6,000-pixel mosaic is an approximately true-color rendering generated using the images acquired through filters admitting light wavelengths of 750, 530, and 480 nanometers. Lighting varied during the nine sols it took to acquire this panorama, resulting in some small image seams within the mosaic. These seams have been smoothed in sky parts of the mosaic to better simulate the vista that a person would see if able to view it all at the same time on Mars. Opportunity's tracks leading back to the north (center of the panorama) are a reminder of the rover's long trek from Endurance Crater. The deep ruts dug by Opportunity's wheels as it became stuck in the sand appear in the foreground. The crest and trough of the last ripple the rover crossed before getting stuck is visible in the center. These wind-formed sand features are only about 10 to 15 centimeters (4 to 6 inches) tall. The crest of the actual ripple where the rover got stuck can be seen just to the right of center. The tracks and a few other places on and near ripple crests can be seen in this color image to

  15. Electronic and elastic properties of new semiconducting oP(12)-type RuB(2) and OsB(2).

    Science.gov (United States)

    Hao, Xianfeng; Xu, Yuanhui; Gao, Faming

    2011-03-30

    Using first-principles total energy calculations we investigate the structural, elastic and electronic properties of new hypothetical oP(12)-type phase RuB(2) and OsB(2). The calculations indicate that the oP(12)-type phase RuB(2) and OsB(2) are thermodynamically and mechanically stable. Remarkably, the new phases RuB(2) and OsB(2) are predicted to be semiconductors, and the appearance of band gaps is ascribed to the enhanced B-B covalent hybridization. Compared to metallic oP(6)-type RuB(2) and OsB(2) phases, the new phases possess similar mechanical properties and hardness. The combination of the probability of tunable electronic properties, strong stiffness and high hardness make RuB(2) and OsB(2) attractive and interesting for advanced applications. © 2011 IOP Publishing Ltd

  16. Rotor-to-stator rub vibration in centrifugal compressor

    Science.gov (United States)

    Gao, J. J.; Qi, Q. M.

    1985-01-01

    One example of excessive vibration encountered during loading of a centrifugal compressor train (H type compressor with HP casing) is discussed. An investigation was made of the effects of the dynamic load on the bearing stiffness and the rotor-bearing system critical speed. The high vibration occurred at a "threshold load," but the machine didn't run smoothly due to rubs even when it had passed through the threshold load. The acquisition and discussion of the data taken in the field as well as a description of the case history which utilizes background information to identify the malfunction conditions is presented. The analysis shows that the failures, including full reverse precession rub and exact one half subharmonic vibration, were caused by the oversize bearings and displacement of the rotor center due to foundation deformation and misalignment between gear shafts, etc. The corrective actions taken to alleviate excessive vibration and the problems which remain to be solved are also presented.

  17. Effects of eye rubbing on the levels of protease, protease activity and cytokines in tears: relevance in keratoconus.

    Science.gov (United States)

    Balasubramanian, Sivaraman A; Pye, David C; Willcox, Mark D P

    2013-03-01

    Proteases, protease activity and inflammatory molecules in tears have been found to be relevant in the pathogenesis of keratoconus. We sought to determine the influence of eye rubbing on protease expression, protease activity and concentration of inflammatory molecules in tears. Basal tears were collected from normal volunteers before and after 60 seconds of experimental eye rubbing. The total amount of matrix metalloproteinase (MMP)-13 and inflammatory molecules interleukin (IL)-6 and tumour necrosis factor (TNF)-α in the tear samples were measured using specific enzyme-linked immunosorbent assays (ELISA). Tear collagenase activity was investigated using a specific activity assay. The concentrations of MMP-13 (51.9 ± 34.3 versus 63 ± 36.8 pg/ml, p = 0.006), IL-6 (1.24 ± 0.98 versus 2.02 ± 1.52 pg/ml, p = 0.004) and TNF-α (1.16 ± 0.74 versus 1.44 ± 0.66 pg/ml, p = 0.003) were significantly increased in normal subjects after eye rubbing. The experimental eye rub did not alter significantly the collagenase activity (5.02 ± 3 versus 7.50 ± 3.90 fluorescent intensity units, p = 0.14) of tears. Eye rubbing for 60 seconds increased the level of tear MMP-13, IL-6 and TNF-α in normal study subjects. This increase in protease, protease activity and inflammatory mediators in tears after eye rubbing may be exacerbated even further during persistent and forceful eye rubbing seen in people with keratoconus and this in turn may contribute to the progression of the disease. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  18. B11 NMR in the layered diborides OsB2 and RuB2

    Science.gov (United States)

    Suh, B. J.; Zong, X.; Singh, Y.; Niazi, A.; Johnston, D. C.

    2007-10-01

    B11 nuclear magnetic resonance (NMR) measurements have been performed on B11 enriched OsB2 and RuB2 polycrystalline powder samples in an external field of 4.7T and in the temperature range, 4.2KOsB2 and RuB2 , respectively. The experimental results indicate that a p character dominates the conduction electron wave function at the B site with a negligibly small s character in both compounds.

  19. Change in antioxidant and lignifying enzyme activities in rubbing ...

    African Journals Online (AJOL)

    Fourier transform infrared (FTIR) analyses revealed that lignin synthesized in response to mechanical elicitation displayed a distinct structure, substantially enriched in syringyl (S) units, as compared to constitutive lignin. Taken together, our results suggest that the decrease in rubbed internode length is as a result of IAA ...

  20. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  1. Vaginal Swab Test Compared With the Urethral Q-tip Test for Urethral Mobility Measurement: A Randomized Controlled Trial.

    Science.gov (United States)

    Meyer, Isuzu; Szychowski, Jeff M; Illston, Jana D; Parden, Alison M; Richter, Holly E

    2016-02-01

    To assess whether use of a vaginal cotton-tipped swab is equivalent to the standard Q-tip test regarding urethral mobility. Secondarily, to examine whether both tests agree in hypermobility diagnosis, discomfort level, and patients' preference. In this randomized crossover trial, women with stress urinary incontinence without prolapse beyond the hymen were randomized to undergo either a vaginal or urethral mobility test first followed by the alternate approach. The primary outcome was the difference in rotation angle, from resting to maximum strain, between tests. The equivalence margin was ±10°. The secondary outcome was agreement in hypermobility diagnosis using two definitions: 1) maximum straining angle of 30° or greater from the horizontal plane; and 2) rotation angle 30° or greater. Discomfort was assessed using a 0-10 visual analog scale. Using 90% power assuming a standard deviation of 20°, 36 and 139 patients were needed for 10° and 5° equivalence margins, respectively. From January 2014 to March 2015, 140 women were randomized. The mean difference between the two tests was 5.1° (95% confidence interval 3.2-6.9°), meeting the predefined equivalence criteria. In the hypermobility diagnosis, the urethral and vaginal tests had no disagreement using definition 1 (P=.23), whereas the two tests disagreed using definition 2 (P=.03). The urethral approach had a higher discomfort level (Pstandard Q-tip test in measuring urethral mobility with less discomfort and is preferred by patients.

  2. Nonlinear Coupled Dynamics of a Rod Fastening Rotor under Rub-Impact and Initial Permanent Deflection

    Directory of Open Access Journals (Sweden)

    Liang Hu

    2016-10-01

    Full Text Available A nonlinear coupled dynamic model of a rod fastening rotor under rub-impact and initial permanent deflection was developed in this paper. The governing motion equation was derived by the D’Alembert principle considering the contact characteristic between disks, nonlinear oil-film force, rub-impact force, unbalance mass, etc. The contact effects between disks was modeled as a flexural spring with cubical nonlinear stiffness. The coupled nonlinear dynamic phenomena of the rub-impact rod fastening rotor bearing system with initial permanent deflection were investigated by the fourth-order Runge-Kutta method. Bifurcation diagram, vibration waveform, frequency spectrum, shaft orbit and Poincaré map are used to illustrate the rich diversity of the system response with complicated dynamics. The studies indicate that the coupled dynamic responses of the rod fastening rotor bearing system under rub-impact and initial permanent deflection exhibit a rich nonlinear dynamic diversity, synchronous periodic-1 motion, multiple periodic motion, quasi-periodic motion and chaotic motion can be observed under certain conditions. Larger radial stiffness of the stator will simplify the system motion and make the oil whirl weaker or even disappear at a certain rotating speed. With the increase of initial permanent deflection length, the instability speed of the system gradually rises, and the chaotic motion region gets smaller and smaller. The corresponding results can provide guidance for the fault diagnosis of a rub-impact rod fastening rotor with initial permanent deflection and contribute to the further understanding of the nonlinear dynamic characteristics of the rod fastening rotor bearing system.

  3. Quantity of ethanol absorption after excessive hand disinfection using three commercially available hand rubs is minimal and below toxic levels for humans

    Directory of Open Access Journals (Sweden)

    Toma Cyril D

    2007-10-01

    Full Text Available Abstract Background Despite the increasing promotion of alcohol-based hand rubs and the worldwide use of ethanol-based hand rubs in hospitals only few studies have specifically addressed the issue of ethanol absorption when repeatedly applied to human skin. The aim of this study was to assess if ethanol absorption occurs during hygienic and surgical hand disinfection using three different alcohol-based hand-rubs, and to quantify absorption levels in humans. Methods Twelve volunteers applied three hand-rubs containing 95% (hand-rub A, 85% (hand-rub B and 55% ethanol (hand-rub C; all w/w. For hygienic hand disinfection, 4 mL were applied 20 times for 30 s, with 1 minute break between applications. For surgical hand disinfection, 20 mL of each hand rub was applied to hands and arms up to the level of the elbow 10 times for 3 minutes, with a break of 5 minutes between applications. Blood concentrations of ethanol and acetaldehyde were determined immediately prior and up to 90 minutes after application using head space gas chromatography. Results The median of absorbed ethanol after hygienic hand disinfection was 1365 mg (A, 630 mg (B, and 358 mg (C. The proportion of absorbed ethanol was 2.3% (A, 1.1% (B, and 0.9% (C. After surgical hand disinfection, the median of absorbed ethanol was 1067 mg (A, 1542 mg (B, and 477 mg (C. The proportion of absorbed ethanol was 0.7% (A, 1.1% (B, and 0.5% (C. The highest median acetaldehyde concentration after 20 hygienic hand disinfections was 0.57 mg/L (hand-rub C, after 30 min, after 10 surgical hand disinfections 3.99 mg/L (hand-rub A, after 20 minutes. Conclusion The overall dermal and pulmonary absorption of ethanol was below toxic levels in humans and allows the conclusion that the use of the evaluated ethanol-based hand-rubs is safe.

  4. Increase of ionic conductivity in the microporous lithosilicate RUB-29 by Na-ion exchange processes

    International Nuclear Information System (INIS)

    Park, S.-H.; Senyshyn, A.; Paulmann, C.

    2007-01-01

    The ionic conductivity in the zeolite-like lithosilicate RUB-29 (Cs 14 Li 24 [Li 18 Si 72 O 172 ].14H 2 O [S.-H. Park, J.B. Parise, H. Gies, H. Liu, C.P. Grey, B.H. Toby, J. Am. Chem. Soc. 122 (2000) 11023-11024]) increases via simple ion-exchange processes, in particular when Na cations replace a part of Cs + and Li + of the material. The resulting ionic conductivity value of 3.2x10 -3 S cm -1 at 885 K is about two orders higher than that for the original material [S.-H. Park, J.B. Parise, M.E. Franke, T. Seydel, C. Paulmann, Micropor. Mesopor. Mater., in print ( (doi:10.1016/j.micromeso.2007.03.040) available online since April 19, 2007)]. The structural basis of a Na + -exchanged RUB-29 sample (Na-RUB-29) at 673 K could be elucidated by means of neutron powder diffraction. Rietveld refinements confirmed the replacement of Na + for both parts of Cs and Li cations, agreeing with idealized cell content, Na 8 Cs 8 Li 40 Si 72 O 172 . As a result of the incorporation of Na + in large pores, the number of Li + vacancies in dense Li 2 O-layers of the structure could increase. This can be one of the main reasons for the improved conductivity in Na-RUB-29. In addition, mobile Na cations may also contribute to the conductivity in Na-RUB-29 as continuous scattering length densities were found around the sites for Na in difference Fourier map. - Graphical abstract: Li 2 O-layers formed by edge- and corner-sharing LiO 4 - and LiO 3 -moieties in the zeolite-like lithosilicate RUB-29 provide optimal pathways for conducting Li + . The number of empty Li sites in this layer-like configuration could increase via 'simple' Na + -exchange processes, promoting fast Li motions

  5. A floating right heart thrombus in transit across tricuspid valve causing an endocardial friction rub

    Directory of Open Access Journals (Sweden)

    Babu Kanjirakadavath

    2013-07-01

    Full Text Available We report a 42-year-old lady on combined oral contraceptive pills with deep venous thrombosis and mild pulmonary embolism, who developed shock, while being treated with heparin. On auscultation, there was an unexpected loud, superficial, squeaky, triphasic friction rub over the left lower parasternal area. Simultaneous echocardiogram revealed a large serpiginous, freely floating mass in right atrium, prolapsing freely to right ventricular inlet across the tricuspid valve. The endocardial friction rub persisted for about 24 h as long as the thrombus was intracardiac and disappeared when the thrombus disappeared from right heart, occluding the proximal left pulmonary artery. She died due to shock awaiting surgery. We highlight that such a rub in a patient with deep venous thrombosis, though rare, may be an important clue to impending pulmonary embolism.

  6. Effect of Tip Shape of Frictional Stir Burnishing Tool on Processed Layer’s Hardness, Residual Stress and Surface Roughness

    Directory of Open Access Journals (Sweden)

    Yoshimasa Takada

    2018-01-01

    Full Text Available Friction stir burnishing (FSB is a surface-enhancement method used after machining, without the need for an additional device. The FSB process is applied on a machine that uses rotation tools (e.g., machining center or multi-tasking machine. Therefore, the FSB process can be applied immediately after the cutting process using the same machine tool. Here, we apply the FSB to the shaft materials of 0.45% C steel using a multi-tasking machine. In the FSB process, the burnishing tool rotates at a high-revolution speed. The thin surface layer is rubbed and stirred as the temperature is increased and decreased. With the FSB process, high hardness or compressive residual stress can be obtained on the surface layer. However, when we applied the FSB process using a 3 mm diameter sphere tip shape tool, the surface roughness increased substantially (Ra = 20 µm. We therefore used four types of tip shape tools to examine the effect of burnishing tool tip radius on surface roughness, hardness, residual stress in the FSB process. Results indicated that the surface roughness was lowest (Ra = 10 µm when the tip radius tool diameter was large (30 mm.

  7. Structural geology of the Rub' Al-Khali Basin, Saudi Arabia

    Science.gov (United States)

    Stewart, S. A.

    2016-10-01

    The Rub' Al-Khali basin lies below a Quaternary sand sea, and the structural evolution from the Late Precambrian to Neogene is known only from reflection seismic, gravity, and magnetic data, and wells. Gravity and magnetic data show north-south and northwest-southeast trends, matching mapped Precambrian faults. The deepest structures imaged on reflection seismic data are undrilled Precambrian rifts filled with layered strata at depths up to 13 km. The distribution of Ediacaran-Cambrian Ara/Hormuz mobile salt is restricted to an embayment in the eastern Rub' Al-Khali. The Precambrian rifts show local inversion and were peneplained at base Phanerozoic. A broad crustal-scale fold (Qatar Arch) developed in the Carboniferous and amplified in the Late Triassic, separating subbasins in the west and east Rub' Al-Khali. A phase of kilometer-scale folding occurred in the Late Cretaceous, coeval with thrusting and ophiolite obduction in eastern Oman. These folds trend predominantly north-south, oblique to the northwesterly shortening direction, and occasionally have steep fault zones close to their axial surfaces. The trend and location of these folds closely matches the Precambrian lineaments identified in this study, demonstrating preferential reactivation of basement structures. Compression along the Zagros suture reactivated these folds in the Neogene, this time the result of highly oblique, north-northeast to south-southwest shortening. Cretaceous-Tertiary fold style is interpreted as transpression with minor strain partitioning. Permian, Jurassic, and Eocene evaporite horizons played no role in the structural evolution of the basin, but the Eocene evaporites caused widespread kilometer-scale dissolution collapse structures in the basin center.

  8. A finite element-based algorithm for rubbing induced vibration prediction in rotors

    Science.gov (United States)

    Behzad, Mehdi; Alvandi, Mehdi; Mba, David; Jamali, Jalil

    2013-10-01

    In this paper, an algorithm is developed for more realistic investigation of rotor-to-stator rubbing vibration, based on finite element theory with unilateral contact and friction conditions. To model the rotor, cross sections are assumed to be radially rigid. A finite element discretization based on traditional beam theories which sufficiently accounts for axial and transversal flexibility of the rotor is used. A general finite element discretization model considering inertial and viscoelastic characteristics of the stator is used for modeling the stator. Therefore, for contact analysis, only the boundary of the stator is discretized. The contact problem is defined as the contact between the circular rigid cross section of the rotor and “nodes” of the stator only. Next, Gap function and contact conditions are described for the contact problem. Two finite element models of the rotor and the stator are coupled via the Lagrange multipliers method in order to obtain the constrained equation of motion. A case study of the partial rubbing is simulated using the algorithm. The synchronous and subsynchronous responses of the partial rubbing are obtained for different rotational speeds. In addition, a sensitivity analysis is carried out with respect to the initial clearance, the stator stiffness, the damping parameter, and the coefficient of friction. There is a good agreement between the result of this research and the experimental result in the literature.

  9. Improved flare tip design

    Energy Technology Data Exchange (ETDEWEB)

    Gogolek, P. [Natural Resources Canada, Ottawa, ON (Canada). CANMET Energy Technology Centre

    2004-07-01

    This paper discusses the testing procedures and development of an improved flare tip design. Design objectives included performance equal to or better than utility flares at low wind speed; conversion efficiency; fuel slip; smoking; significant improvement at high wind speed; and no increase in trace emissions. A description of the testing facility of the flare tip was provided, with reference to the fact that the facility allowed for realistic near full scale gas flares in a single-pass flare test facility. Other details of the facility included: an adjustable ceiling; high capacity variable speed fan; sampling ports along working section in stack; windows along working section; and air cooled walls, floor, and ceiling. The fuels used in the flare tip included natural gas, propane, gasoline and inert gases. Details of wind speed, appurtenances and turbulence generating grids were presented, with reference to continuous gas emission measurements. A list of design constraints was provided. Flare performance included wind speed, turbulence and fuel composition. A chart of conversion inefficiencies with a correlation of wind speed and turbulence, fuel flow and pipe size was also presented. Several new tip designs were fabricated for testing, with screening tests for comparison to basic pipe and ranking designs. Significant improvements were found in one of the new designs, including results with 30 per cent propane in fuel. Emissions reduction from 10 to 35 per cent were noted. It was concluded that future work should focus on evaluating improved tip for stability at low wind speeds. Fuel slips are the primary source of emissions, and it was recommended that further research is necessary to improve existing flare tips. tabs, figs.

  10. Life Cycle Analysis of High Quality Recycled Aggregate Produced byHeating and Rubbing Method

    Science.gov (United States)

    Shima, Hirokazu; Matsuhashi, Ryuji; Yoshida, Yoshikuni; Tateyashiki, Hisashi

    Most of demolished concrete is recycled as road subbase, but its generation is expected to increase rapidly and exceed the demand of road subbase in a near future. To promote the recycling of concrete, the technology to produce high quality recycled aggregate by the heating and rubbing method has been developed. In this method, demolished concrete is heated up to about 300°C in a heater to make cement paste brittle with its dehydration. The heated concrete is then rubbed in two mills to recover the recycled aggregate, while the paste is removed from the surface of aggregate and collected as cement fine powder. In this method, much energy is consumed to heat and rub concrete; however, the cement fine powder is utilized for a soil stabilizer and cement raw materials, so that the environmental load is reduced in cement manufacturing. The life cycle analysis of the recycled aggregate is carried out to evaluate this technology. As a result, the life cycle CO2 is a negative value because the deduction of CO2 emission in cement manufacturing by the powder is much large. This technology is proved to be very effective to reduce CO2.

  11. Chromosome-Encoded Broad-Spectrum Ambler Class A β-Lactamase RUB-1 from Serratia rubidaea.

    Science.gov (United States)

    Bonnin, Rémy A; Didi, Jennifer; Ergani, Ayla; Lima, Sandra; Naas, Thierry

    2017-02-01

    Whole-genome sequencing of Serratia rubidaea CIP 103234 T revealed a chromosomally located Ambler class A β-lactamase gene. The gene was cloned, and the β-lactamase, RUB-1, was characterized. RUB-1 displayed 74% and 73% amino acid sequence identity with the GIL-1 and TEM-1 penicillinases, respectively, and its substrate profile was similar to that of the latter β-lactamases. Analysis by 5' rapid amplification of cDNA ends revealed promoter sequences highly divergent from the Escherichia coli σ 70 consensus sequence. This work further illustrates the heterogeneity of β-lactamases among Serratia spp. Copyright © 2017 American Society for Microbiology.

  12. An overlooked mandibular-rubbing behavior used during recruitment by the African weaver ant, Oecophylla longinoda.

    Directory of Open Access Journals (Sweden)

    Olivier Roux

    2010-02-01

    Full Text Available In Oecophylla, an ant genus comprising two territorially dominant arboreal species, workers are known to (1 use anal spots to mark their territories, (2 drag their gaster along the substrate to deposit short-range recruitment trails, and (3 drag the extruded rectal gland along the substrate to deposit the trails used in long-range recruitment. Here we study an overlooked but important marking behavior in which O. longinoda workers first rub the underside of their mandibles onto the substrate, and then--in a surprising posture--tilt their head and also rub the upper side of their mandibles. We demonstrate that this behavior is used to recruit nestmates. Its frequency varies with the rate at which a new territory, a sugary food source, a prey item, or an alien ant are discovered. Microscopy analyses showed that both the upper side and the underside of the mandibles possess pores linked to secretory glands. So, by rubbing their mandibles onto the substrate, the workers probably spread a secretion from these glands that is involved in nestmate recruitment.

  13. Topotactic conversion of layered silicate RUB-15 to silica sodalite through interlayer condensation in N-methylformamide.

    Science.gov (United States)

    Koike, Masakazu; Asakura, Yusuke; Sugihara, Megumi; Kuroda, Yoshiyuki; Tsuzura, Hidehiro; Wada, Hiroaki; Shimojima, Atsushi; Kuroda, Kazuyuki

    2017-08-08

    Silica sodalite was obtained using topotactic conversion of layered silicate RUB-15 through stepwise processes that consisted of the control of stacking sequence of the layers, interlayer condensation by refluxing, and elimination of intercalated guest species. The interlayer condensation of RUB-15, in which acetic acid was pre-intercalated between the layers to control the stacking sequence, afforded a sodalite framework containing organic guest species by refluxing in N-methylformamide (NMF). The pre-intercalated acetic acid molecules were largely replaced with NMF. This formation process of silica sodalite containing large amounts of intercalated organic guest species is in clear contrast to the previously reported process that used direct calcination of an intercalation compound of layered RUB-15 accommodating acetic acid between the layers. Calcination of the condensed product provided sodalite with fewer defects than the directly calcined product, thus indicating the advantage of the stepwise process. The method reported here is useful for the preparation of pure silica sodalite with relatively low defects and plate-like morphology.

  14. Morphing Wing-Tip Open Loop Controller and its Validation During Wind Tunnel Tests at the IAR-NRC

    Directory of Open Access Journals (Sweden)

    Mohamed Sadok GUEZGUEZ

    2016-09-01

    Full Text Available In this project, a wing tip of a real aircraft was designed and manufactured. This wing tip was composed of a wing and an aileron. The wing was equipped with a composite skin on its upper surface. This skin changed its shape (morphed by use of 4 electrical in-house developed actuators and 32 pressure sensors. These pressure sensors measure the pressures, and further the loads on the wing upper surface. Thus, the upper surface of the wing was morphed using these actuators with the aim to improve the aerodynamic performances of the wing-tip. Two types of ailerons were designed and manufactured: one aileron is rigid (non-morphed and one morphing aileron. This morphing aileron can change its shape also for the aerodynamic performances improvement. The morphing wing-tip internal structure is designed and manufactured, and is presented firstly in the paper. Then, the modern communication and control hardware are presented for the entire morphing wing tip equipped with actuators and sensors having the aim to morph the wing. The calibration procedure of the wing tip is further presented, followed by the open loop controller results obtained during wind tunnel tests. Various methodologies of open loop control are presented in this paper, and results obtained were obtained and validated experimentally through wind tunnel tests.

  15. Waterless Hand Rub Versus Traditional Hand Scrub Methods for Preventing the Surgical Site Infection in Orthopedic Surgery.

    Science.gov (United States)

    Iwakiri, Kentaro; Kobayashi, Akio; Seki, Masahiko; Ando, Yoshiyuki; Tsujio, Tadao; Hoshino, Masatoshi; Nakamura, Hiroaki

    2017-11-15

    MINI: Fourteen hundred consecutive patients were investigated for evaluating the utility of waterless hand rub before orthopaedic surgery. The risk in the surgical site infection incidence was the same, but costs of liquids used for hand hygiene were cheaper and the hand hygiene time was shorter for waterless protocol, compared with traditional hand scrub. A retrospective cohort study with prospectively collected data. The aim of this study was to compare SSI incidences, the cost of hand hygiene agents, and hand hygiene time between the traditional hand scrub and the waterless hand rub protocols before orthopedic surgery. Surgical site infections (SSI) prolong hospitalization and are a leading nosocomial cause of morbidity and a source of excess cost. Recently, a waterless hand rub protocol comprising alcohol based chlorhexidine gluconate for use before surgery was developed, but no studies have yet examined its utility in orthopedic surgery. Fourteen hundred consecutive patients who underwent orthopedic surgery (spine, joint replacement, hand, and trauma surgeries) in our hospital since April 1, 2012 were included. A total of 712 cases underwent following traditional hand scrub between April 1, 2012 and April 30, 2013 and 688 cases underwent following waterless hand rub between June 1, 2013 and April 30, 2014. We compared SSI incidences within all and each subcategory between two hand hygiene protocols. All patients were screened for SSI within 1 year after surgery. We compared the cost of hand hygiene agents and hand hygiene time between two groups. The SSI incidences were 1.3% (9 of 712) following the traditional protocol (2 deep and 7 superficial infections) and 1.1% (8 of 688) following the waterless protocol (all superficial infections). There were no significant differences between the two groups. The costs of liquids used for one hand hygiene were about $2 for traditional hand scrub and less than $1 for waterless hand rub. The mean hand hygiene time was 264

  16. Characters Feature Extraction Based on Neat Oracle Bone Rubbings

    OpenAIRE

    Lei Guo

    2013-01-01

    In order to recognize characters on the neat oracle bone rubbings, a new mesh point feature extraction algorithm was put forward in this paper by researching and improving of the existing coarse mesh feature extraction algorithm and the point feature extraction algorithm. Some improvements of this algorithm were as followings: point feature was introduced into the coarse mesh feature, the absolute address was converted to relative address, and point features have been changed grid and positio...

  17. AERODYNAMICS OF WING TIP SAILS

    Directory of Open Access Journals (Sweden)

    MUSHTAK AL-ATABI

    2006-06-01

    Full Text Available Observers have always been fascinated by soaring birds. An interesting feature of these birds is the existence of few feathers extending from the tip of the wing. In this paper, small lifting surfaces were fitted to the tip of a NACA0012 wing in a fashion similar to that of wing tip feathers. Experimental measurements of induced drag, longitudinal static stability and trailing vortex structure were obtained.The tests showed that adding wing tip surfaces (sails decreased the induced drag factor and increased the longitudinal static stability. Results identified two discrete appositely rotated tip vortices and showed the ability of wing tip surfaces to break them down and to diffuse them.

  18. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    Science.gov (United States)

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  19. A general electromagnetic excitation model for electrical machines considering the magnetic saturation and rub impact

    Science.gov (United States)

    Xu, Xueping; Han, Qinkai; Chu, Fulei

    2018-03-01

    The electromagnetic vibration of electrical machines with an eccentric rotor has been extensively investigated. However, magnetic saturation was often neglected. Moreover, the rub impact between the rotor and stator is inevitable when the amplitude of the rotor vibration exceeds the air-gap. This paper aims to propose a general electromagnetic excitation model for electrical machines. First, a general model which takes the magnetic saturation and rub impact into consideration is proposed and validated by the finite element method and reference. The dynamic equations of a Jeffcott rotor system with electromagnetic excitation and mass imbalance are presented. Then, the effects of pole-pair number and rubbing parameters on vibration amplitude are studied and approaches restraining the amplitude are put forward. Finally, the influences of mass eccentricity, resultant magnetomotive force (MMF), stiffness coefficient, damping coefficient, contact stiffness and friction coefficient on the stability of the rotor system are investigated through the Floquet theory, respectively. The amplitude jumping phenomenon is observed in a synchronous generator for different pole-pair numbers. The changes of design parameters can alter the stability states of the rotor system and the range of parameter values forms the zone of stability, which lays helpful suggestions for the design and application of the electrical machines.

  20. Comparison of 3 in vivo methods for assessment of alcohol-based hand rubs.

    Science.gov (United States)

    Edmonds-Wilson, Sarah; Campbell, Esther; Fox, Kyle; Macinga, David

    2015-05-01

    Alcohol-based hand rubs (ABHRs) are the primary method of hand hygiene in health-care settings. ICPs increasingly are assessing ABHR product efficacy data as improved products and test methods are developed. As a result, ICPs need better tools and recommendations for how to assess and compare ABHRs. Two ABHRs (70% ethanol) were tested according to 3 in vivo methods approved by ASTM International: E1174, E2755, and E2784. Log10 reductions were measured after a single test product use and after 10 consecutive uses at an application volume of 2 mL. The test method used had a significant influence on ABHR efficacy; however, in this study the test product (gel or foam) did not significantly influence efficacy. In addition, for all test methods, log10 reductions obtained after a single application were not predictive of results after 10 applications. Choice of test method can significantly influence efficacy results. Therefore, when assessing antimicrobial efficacy data of hand hygiene products, ICPs should pay close attention to the test method used, and ensure that product comparisons are made head to head in the same study using the same test methodology. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. E-learning may improve adherence to alcohol-based hand rubbing: a cohort study

    DEFF Research Database (Denmark)

    Laustsen, Sussie; Bibby, Bo Martin; Kristensen, Brian

    2009-01-01

    BACKGROUND: Since 2004, we have promoted alcohol-based hand rubbing (HR) with an e-learning program (ELP) among hospital staff. This study sought to determine whether an ELP improves adherence to correct HR. METHODS: This was a cohort study of staff members at Aarhus University Hospital, Skejby, ...

  2. An Optical Fiber Bundle Sensor for Tip Clearance and Tip Timing Measurements in a Turbine Rig

    Directory of Open Access Journals (Sweden)

    María Asunción Illarramendi

    2013-06-01

    Full Text Available When it comes to measuring blade-tip clearance or blade-tip timing in turbines, reflective intensity-modulated optical fiber sensors overcome several traditional limitations of capacitive, inductive or discharging probe sensors. This paper presents the signals and results corresponding to the third stage of a multistage turbine rig, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on the turbine casing. To eliminate the influence of light source intensity variations and blade surface reflectivity, the sensing principle is based on the quotient of the voltages obtained from the two receiving bundle legs. A discrepancy lower than 3% with respect to a commercial sensor was observed in tip clearance measurements. Regarding tip timing measurements, the travel wave spectrum was obtained, which provides the average vibration amplitude for all blades at a particular nodal diameter. With this approach, both blade-tip timing and tip clearance measurements can be carried out simultaneously. The results obtained on the test turbine rig demonstrate the suitability and reliability of the type of sensor used, and suggest the possibility of performing these measurements in real turbines under real working conditions.

  3. A comparative study of hand hygiene and alcohol-based hand rub use among Irish nursing and medical students.

    Science.gov (United States)

    Kingston, Liz M; O'Connell, Nuala H; Dunne, Colum P

    2018-04-01

    In Ireland, the setting for this study, the national prevalence rate of health care-associated infection (HCAI) in acute-care facilities is 5.2%. Hand hygiene and in particular hand rubbing using alcohol-based hand rub (ABHR) is highly efficacious in preventing HCAI transmission. Yet, compliance among healthcare professionals is sub-optimal. Less is known about the practices of nursing and medical students and no study comparing practices among these groups in Ireland was found. Hence, the aim of this study was to provide insight into the current hand hygiene and hand rubbing practices of nursing and medical students in Ireland and, by doing so, contribute to the broader understanding of this topic. This observational study employed a cross-sectional, self-reported design. An electronically administered questionnaire was sent to all nursing and medical students from one university. Data were analysed using appropriate software. The response rate was 37% (323/872). Higher compliance with the World Health Organisation 'my five moments for hand hygiene' model was reported among nursing students (NS) than medical students (MS), with scope for improvement in both disciplines identified. Hand hygiene compliance was highest after body fluid exposure (99.5% NS, 91% MS) and lowest after touching a patient's surroundings (61.5% NS, 57.5% MS). Attitudes towards hand rubbing were largely positive in both disciplines. 16% of NS were not aware of the clinical contraindications to ABHR use, compared to 45% of MS. 9% of NS did not know when to use soap and water and when to use ABHR, compared to 36% of MS. In contrast, more medical students (46%) than nursing students (22%) were routinely using alcohol-based hand rub for decontamination of hands as recommended. Results suggest scope to review current hand hygiene curricula focusing on the knowledge gaps, the practice deficits and the barriers to ABHR usage identified. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. A Kinetic Study Using Evaporation of Different Types of Hand-Rub Sanitizers

    Science.gov (United States)

    Pinhas, Allan R.

    2010-01-01

    Alcohol-based hand-rub sanitizers are the types of products that hospital professionals use very often. These sanitizers can be classified into two major groups: those that contain a large quantity of thickener, and thus are a gel, and those that contain a small quantity of thickener, and thus remain a liquid. In an effort to create a laboratory…

  5. Characterization of metal-coated fiber tip for NSOM lithography by tip-to-tip scan

    International Nuclear Information System (INIS)

    Kubicova, I.; Pudis, D.; Suslik, L.; Skriniarova, J.

    2011-01-01

    For the optical field characterization, a tip-to-tip scan of two metal-coated fiber tips with circular aperture at the apex was performed. The optical field irradiated from the fiber probe in illumination mode was analyzed by NSOM represented by fiber probe in collection mode. The near-field intensity profile of the source fiber tip in the plane perpendicular to the axis of the tip was taken. Experimental stage requires high resolution 3D motion system controlled by computer (Fig. 1). The source and the detector fiber tip were placed on the moving and static part of the 3D nanoposition system, respectively. As a light source, a modulated 473 nm DPSS laser was used. After the source fiber tip characterization, the NSOM lithography was performed. In the experimental setup from Fig. 1, the detector fiber tip was replaced by a sample fixed in a vacuum holder. As a sample, a 600 nm positive photoresist AZ 5214E was spin-coated on a GaAs substrate. Exposure was carried out by irradiation of the sample at desired positions through the fiber tip aperture. The sample was developed in AZ 400K developer for 30 s and rinsed in DI water. A promising tip-to-tip scanning technique for characterization of metal-coated fiber tips with aperture at the apex was presented. Nearly-circular aperture shapes were documented from NSOM measurements with diameter estimated to be less than 460 nm. By knowing the source-detector distance and the FWHM of the near-field intensity profile, the tip-to-tip scan proves an easy and fast method to analyze the fiber tip aperture properties. The fiber tip resolution was confirmed by preparation of 2D planar structures in thin photoresist layer, where the NSOM lithography uses the metal-coated fiber tip characterized in previous section. (authors)

  6. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ... Developers +YouTube Terms Privacy Policy & Safety Send feedback Test new features Loading... Working... Sign in to add ...

  7. Peregrinaciones parisinas: Rubén Darío

    Directory of Open Access Journals (Sweden)

    Beatriz Colombi

    1996-11-01

    Full Text Available Hacia 1900 se nuclea en París un grupo de corresponsales latinoamericanos conformando una suerte de enclave que reúne a figuras como Rubén Darío, Manuel Ugarte, Amado Nervo o Enrique Gómez Carrillo. Desde sus respectivas columnas estos cronistas construyen imágenes del mundo moderno atravesadas por el conflicto de pertenencia y marginalidad respecto al mismo. Este trabajo analiza las entregas que Rubén Darío escribe para La Nación de Buenos Aires durante la Feria Internacional de Paris de 1900, en relación con su contexto discursivo. En la enunciación de estas crónicas se alternan pasajes donde prima la superficialidad de la crónica elegante parisina con otras secciones argumentativas que dan cuenta de los desplazamientos de este sujeto entre el 'chroniqueur' y el intelectual que interviene -con la autoridad que le otorga su liderazgo estético- en el campo de los sucesos políticos, desmoronando cualquier 'fetichización' del espectáculo. Darío trama en su crónica la línea 'ondulante' de su prosa de artista con la línea 'informativa' de su tarea de diarista, imponiendo una marca 'modern style' a su escritura, que privilegia imágenes donde se fusionan elementos de ámbitos dispares; también se contamina de la retórica del acontecimiento moderno, en una hibridez propia del efecto sumativo de ese vasto mercado. Las crónicas, reunidas luego en Peregrinaciones de 1901, señalan también el pasaje entre el gran mercado cultural y el pequeño mercado estético, en una posición anfibia propia de esta textualidad

  8. Influence of rubbing-alignment on microwave modulation induced by liquid crystal

    Directory of Open Access Journals (Sweden)

    Wenjiang Ye

    2015-06-01

    Full Text Available The microwave modulation induced by liquid crystal is decided by the liquid crystal director distribution under an external applied voltage. The rubbing-alignment of substrate has an effect on the liquid crystal director, which must result in the change of microwave phase-shift. To illustrate the influence of rubbing-alignment on the microwave phase-shift, the microwave modulation property of twisted nematic liquid crystal is researched adopting the elastic theory of liquid crystal and the finite-difference iterative method. The variations of microwave phase-shift per unit-length for different pre-tilt and pre-twist angles of liquid crystal on the substrate surface and anchoring energy strengths with the applied voltage are numerically simulated. The result indicates that with the increase of pre-tilt angle and with the decrease of anchoring energy strength the weak anchoring twisted cell with pre-twisted angle 90° relative to the strong anchoring non-twisted cell can increase the microwave phase-shift per unit-length. As a result, for achieving the maximum microwave modulation, the weak anchoring twisted cell with pre-tilt angle 5° and anchoring energy strength 1×10−5J/m2 should be selected, which provides a reliably theoretical foundation for the design of liquid crystal microwave modulator.

  9. Antiseptic Effect of Conventional Povidone-Iodine Scrub, Chlorhexidine Scrub, and Waterless Hand Rub in a Surgical Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Tsai, Jui-Chen; Lin, Yen-Kuang; Huang, Yen-Jung; Loh, El-Wui; Wen, Hsiao-Yun; Wang, Chia-Hui; Tsai, Yin-Tai; Hsieh, Wen-Shyang; Tam, Ka-Wai

    2017-04-01

    OBJECTIVE Effective perioperative hand antisepsis is crucial for the safety of patients and medical staff in surgical rooms. The antimicrobial effectiveness of different antiseptic methods, including conventional hand scrubs and waterless hand rubs, has not been well evaluated. DESIGN, SETTING, AND PARTICIPANTS A randomized controlled trial was conducted to investigate the effectiveness of the 3 antiseptic methods among surgical staff of Taipei Medical University-Shuang Ho Hospital. For each method used, a group of 80 participants was enrolled. INTERVENTION Surgical hand cleansing with conventional 10% povidone-iodine scrub, conventional 4% chlorhexidine scrub, or waterless hand rub (1% chlorhexidine gluconate and 61% ethyl alcohol). RESULTS Colony-forming unit (CFU) counts were collected using the hand imprinting method before and after disinfection and after surgery. After surgical hand disinfection, the mean CFU counts of the conventional chlorhexidine (0.5±0.2, Pantiseptic method (P=.0036), but not other variables, predicted the mean CFU count. CONCLUSIONS Conventional chlorhexidine scrub and waterless hand rub were superior to a conventional povidone-iodine product in bacterial inhibition. We recommend using conventional chlorhexidine scrub as a standard method for perioperative hand antisepsis. Waterless hand rub may be used if the higher cost is affordable. Infect Control Hosp Epidemiol 2017;38:417-422.

  10. RANS computations of tip vortex cavitation

    Science.gov (United States)

    Decaix, Jean; Balarac, Guillaume; Dreyer, Matthieu; Farhat, Mohamed; Münch, Cécile

    2015-12-01

    The present study is related to the development of the tip vortex cavitation in Kaplan turbines. The investigation is carried out on a simplified test case consisting of a NACA0009 blade with a gap between the blade tip and the side wall. Computations with and without cavitation are performed using a R ANS modelling and a transport equation for the liquid volume fraction. Compared with experimental data, the R ANS computations turn out to be able to capture accurately the development of the tip vortex. The simulations have also highlighted the influence of cavitation on the tip vortex trajectory.

  11. The effect of full coverage winglets on tip leakage aerodynamics over the plane tip in a turbine cascade

    International Nuclear Information System (INIS)

    Lee, Sang Woo; Cheon, Joo Hong; Zhang, Qiang

    2014-01-01

    Highlights: • The effect of full coverage (FC) winglets on tip leakage aerodynamics is tested. • A qualitative tip gap flow model for the FC winglet is suggested. • The FC winglet of w/p = 10.55% is considered an optimal one for the plane tip. -- Abstract: The effect of full coverage (FC) winglets on tip leakage aerodynamics over the plane tip in a turbine cascade has been investigated with the variation of winglet width (w) up to w/p = 15.83% for a tip gap-to-span (chord) ratio of h/s = 1.36% (h/c = 2.0%). A qualitative tip gap flow model for the FC winglet is suggested on the bases of the near-tip surface flow visualizations. As w/p increases, the passage vortex tends to be weakened meanwhile the tip leakage vortex becomes stronger and wall-jet-like. With an increment of w/p, the mass-averaged aerodynamic loss all over the measurement plane decreases steeply up to w/p = 10.55% and then becomes almost unchanged. Thus, the FC winglet of w/p = 10.55% is considered an optimal one for the plane tip. With respect to the baseline plane tip without winglet, the maximum mass-averaged loss reduction by installing the FC winglet on the plane tip is still somewhat smaller than that by employing the cavity squealer rim on the plane tip surface

  12. Recombinant rubistatin (r-Rub), an MVD disintegrin, inhibits cell migration and proliferation, and is a strong apoptotic inducer of the human melanoma cell line SK-Mel-28.

    Science.gov (United States)

    Carey, Clayton M; Bueno, Raymund; Gutierrez, Daniel A; Petro, Christopher; Lucena, Sara E; Sanchez, Elda E; Soto, Julio G

    2012-02-01

    Disintegrins are low molecular weight peptides isolated from viper venom. These peptides bind to integrin receptors using a conserved binding motif sequence containing an RGD or similar motif. As a consequence, disintegrins can inhibit platelet aggregation and inhibit cell migration, proliferation, and initiate apoptosis in cancer cell lines. Rubistatin is a MVD disintegrin cloned from a Crotalus ruber ruber venom gland. The biological activity of MVD disintegrins is poorly understood. Recombinant rubistatin (r-Rub) was cloned into a pET32b plasmid and expressed in reductase-deficient Escherichia coli. Expression was induced with IPTG and the resulting fusion peptide was affinity purified, followed by thrombin cleavage, and removal of vector coded sequences. r-Rub peptide inhibited ADP-induced platelet aggregation by 54% ± 6.38 in whole blood. We assessed the ability of r-Rub to initiate apoptosis in three human cancer cell lines. Cultures of SK-Mel-28, HeLA, and T24 cells were grown for 24 h with 2.5 μM r-Rub followed by Hoechst staining. Chromatin fragmentation was observed in treated SK-Mel-28, but not in T24 or HeLA cells. A TUNEL assay revealed that 51.55% ± 5.28 of SK-Mel-28 cells were apoptotic after 18 h of treatment with 3.5 μM of r-Rub. Cell migration and proliferation assays were performed in order to further characterize the biological effects of r-Rub on SK-Mel-28 cells. At 3 μM, r-Rub inhibited cell migration by 44.4% ± 0.5, while at 3.5 μM it was able to inhibit cell proliferation by 83% ± 6.0. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Replication of Holograms with Corn Syrup by Rubbing

    Directory of Open Access Journals (Sweden)

    Arturo Olivares-Pérez

    2012-08-01

    Full Text Available Corn syrup films are used to replicate holograms in order to fabricate micro-structural patterns without the toxins commonly found in photosensitive salts and dyes. We use amplitude and relief masks with lithographic techniques and rubbing techniques in order to transfer holographic information to corn syrup material. Holographic diffraction patterns from holographic gratings and computer Fourier holograms fabricated with corn syrup are shown. We measured the diffraction efficiency parameter in order to characterize the film. The versatility of this material for storage information is promising. Holographic gratings achieved a diffraction efficiency of around 8.4% with an amplitude mask and 36% for a relief mask technique. Preliminary results using corn syrup as an emulsion for replicating holograms are also shown in this work.

  14. Replication of Holograms with Corn Syrup by Rubbing

    Science.gov (United States)

    Mejias-Brizuela, Nildia Y.; Olivares-Pérez, Arturo; Ortiz-Gutiérrez, Mauricio

    2012-01-01

    Corn syrup films are used to replicate holograms in order to fabricate micro-structural patterns without the toxins commonly found in photosensitive salts and dyes. We use amplitude and relief masks with lithographic techniques and rubbing techniques in order to transfer holographic information to corn syrup material. Holographic diffraction patterns from holographic gratings and computer Fourier holograms fabricated with corn syrup are shown. We measured the diffraction efficiency parameter in order to characterize the film. The versatility of this material for storage information is promising. Holographic gratings achieved a diffraction efficiency of around 8.4% with an amplitude mask and 36% for a relief mask technique. Preliminary results using corn syrup as an emulsion for replicating holograms are also shown in this work.

  15. Rubella and congenital rubella syndrome: global update La rubéola y el síndrome de rubéola congénita: resumen de la situación actual en el mundo

    Directory of Open Access Journals (Sweden)

    Susan E. Robertson

    2003-11-01

    Full Text Available Worldwide, it is estimated that there are more than 100 000 infants born with congenital rubella syndrome (CRS each year. In 1998, standard case definitions for surveillance of CRS and rubella were developed by the World Health Organization (WHO. In 2001, 123 countries/territories reported a total of 836 356 rubella cases. In the future more countries are expected to report on rubella as a global measles/rubella laboratory network is further developed under the coordination of the WHO. Operational research is being conducted to improve rubella surveillance. This includes projects on initiating CRS surveillance, comparative studies on diagnostic laboratory methods, and molecular epidemiology research to expand the global understanding of patterns of rubella virus circulation. In 1996 a WHO survey found that 78 of 214 reporting countries/territories (36% were using rubella vaccine in their routine immunization services. By the end of 2002 a total of 124 of the 214 counties/territories (58% were using rubella vaccine. Rubella vaccine use varies by stage of economic development: 100% for industrialized countries, 71% for countries with economies in transition, and 48% for developing countries. A safe and effective rubella vaccine is available, and there are proven vaccination strategies for preventing rubella and CRS. A WHO position paper provides guidance on programmatic aspects of rubella vaccine introduction. The introduction of rubella vaccine is cost-effective and cost-beneficial but requires ongoing strengthening of routine immunization services and surveillance systems.Se calcula que cada año nacen en el mundo más de 100 000 niños con síndrome de rubéola congénita (SRC. La Organización Mundial de la Salud (OMS estandarizó en 1998 las definiciones de casos para la vigilancia del SRC y de la rubéola. En 2001, 123 países o territorios notificaron 836 356 casos de rubéola y se espera que el número de países se incremente a medida que

  16. Tip studies using CFD and comparison with tip loss models

    DEFF Research Database (Denmark)

    Hansen, Martin Otto Laver; Johansen, J.

    2004-01-01

    The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD......The flow past a rotating LM8.2 blade equipped with two different tips are computed using CFD. The different tip flows are analysed and a comparison with two different tip loss models is made. Keywords: tip flow, aerodynamics, CFD...

  17. Outbreak of rubella after mass vaccination of children and adult women: challenges for rubella elimination strategies Brote epidémico de rubéola tras la vacunación masiva de niños y mujeres adultas: un reto para las estrategias de eliminación de la rubéola

    Directory of Open Access Journals (Sweden)

    Ivone Andreatta Menegolla

    2011-04-01

    Full Text Available OBJECTIVE: To describe rubella outbreaks and control strategies in the Brazilian state of Rio Grande do Sul before rubella elimination. METHODS: We analyzed rubella and congenital rubella syndrome surveillance data for the state of Rio Grande do Sul and calculated age- and gender-specific incidence of confirmed rubella cases in 2007. We obtained data on measles-rubella doses administered during the outbreak from the state immunization program and reviewed the timing of suspect case notification and implementation of control measures. RESULTS: Of 2 842 confirmed rubella cases reported to the state health department in 2007, 2 145 (75.5% were in males (39.5 cases per 100 000 population and 697 (24.5% were in females (12.3 per 100 000 population. Incidence among 15- to 39-year-olds was 1.8 to 5.5 times higher in males than in females. Rubella genotype 2B was detected in nasopharyngeal specimens from 13 patients from multiple chains of transmission. Eight children were born with congenital rubella syndrome (5.9 cases per 100 000 births in 2008. Delayed notification of initial cases hampered early control efforts, resulting in outbreak spread throughout the state. Rubella transmission was interrupted after mass vaccination of adult men and women as part of a national vaccination campaign. CONCLUSIONS: Routine vaccination strategies and mass vaccination of adolescents and adults for accelerated rubella control and elimination should target men and women.OBJETIVO: Describir los brotes de rubéola y las estrategias para el control de la enfermedad anteriores a la eliminación de la rubéola en el estado brasileño de Rio Grande do Sul. MÉTODOS: Se analizaron los datos de vigilancia epidemiológica sobre la rubéola y el síndrome de rubéola congénita del estado de Rio Grande do Sul y se calculó la incidencia específica por edad y sexo de los casos confirmados de rubéola en el 2007. A partir del programa de vacunación estatal se obtuvieron datos

  18. Moths produce extremely quiet ultrasonic courtship songs by rubbing specialized scales

    DEFF Research Database (Denmark)

    Nakano, Ryo; Skals, Niels; Takanashi, Takuma

    2008-01-01

    level at 1 cm) adapted for private sexual communication in the Asian corn borer moth, Ostrinia furnacalis. During courtship, the male rubs specialized scales on the wing against those on the thorax to produce the songs, with the wing membrane underlying the scales possibly acting as a sound resonator....... The male's song suppresses the escape behavior of the female, thereby increasing his mating success. Our discovery of extremely low-intensity ultrasonic communication may point to a whole undiscovered world of private communication, using "quiet" ultrasound....

  19. Rubén Darío y la pintura Principio ekfrástico y sinestesia // Rubén Darío and painting: Ekphrastic principle and synesthesia

    Directory of Open Access Journals (Sweden)

    Alvaro Salvador

    2016-12-01

    Full Text Available The article examines the relationships between literature and painting in the works of Rubén Darío. The issue is seen in the context of modernis synesthesia, which was strongly present in the literary ideology of the modernist discourse, and it is analyzed with the help of the theories of ekphrasis of Murray Krieger. In Darío’s canonical works painting plays an important role, both in the form of literary references, and the so called “transpositions of art”, in its intent to create a total art.

  20. Attitudes and practices of Irish hospital-based physicians towards hand hygiene and hand rubbing using alcohol-based hand rub: a comparison between 2007 and 2015.

    Science.gov (United States)

    Kingston, L M; Slevin, B L; O'Connell, N H; Dunne, C P

    2017-09-01

    Hand hygiene is the cornerstone of infection prevention and control practices, and reduces healthcare-associated infections significantly. However, international evidence suggests that medical doctors demonstrate poor compliance. To explore and compare practices and attitudes towards hand hygiene, particularly hand rubbing using alcohol-based hand rub (ABHR), among hospital-based physicians in Ireland between 2007 and 2015. In 2007, a random sample of doctors in a large teaching hospital was invited to complete a postal survey using a validated questionnaire. In 2015, the study was replicated among all doctors employed in a university hospital group, including the setting of the original study, using an online survey. Data were analysed using SPSS and Survey Monkey. Predominately positive and improving attitudes and practices were found, with 86% of doctors compliant with hand hygiene before patient contact in 2015, compared with 58% in 2007. Ninety-one percent of doctors were compliant after patient contact in 2015, compared with 76% in 2007. In 2015, only 39% of respondents reported that they 'almost always' used ABHR for hand hygiene. However, this represents 13.5% more than in 2007. Stated barriers to use of ABHR included dermatological issues, poor acceptance, tolerance and poor availability of ABHR products. Greater awareness of hand hygiene guidelines and greater governance appear to have had a positive impact on practice. However, despite this, practice remains suboptimal and there is scope for substantial improvement. Continued and sustained efforts are required in order to build on progress achieved since the World Health Organization hand hygiene guidelines were published in 2009. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Sorption and thermodynamic of cation-basic center interactions of inorganic-organic hybrids synthesized from RUB-18

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, T.R. [Institute of Chemistry, University of Campinas, UNICAMP, P.O. Box 6154, 13084-971 Campinas, Sao Paulo (Brazil); Petrucelli, G.C. [Institute of Chemistry, Federal University of Goias, UFG, P.O. Box 03, 75805-190 Jatai, Goias (Brazil); Airoldi, C., E-mail: airoldi@iqm.unicamp.br [Institute of Chemistry, University of Campinas, UNICAMP, P.O. Box 6154, 13084-971 Campinas, Sao Paulo (Brazil)

    2010-04-20

    Synthesized nanostructured hybrids from RUB-18 layered silicate, containing one (N) or three (3N) basic nitrogen atoms attached to pendant chains were applied for copper, nickel and cobalt sorptions. The isotherms obtained from batchwise processes were adjusted to the Freundlich and the Langmuir-Freundlich models for heterogeneous systems. The basic nitrogen centers/acidic cation interactions were followed by calorimetry under batchwise conditions and the results were analyzed by a modified Langmuir equation. The exothermic enthalpic values of -2.50 {+-} 0.30, -1.62 {+-} 0.10 and -1.35 {+-} 0.20 and -15.61 {+-} 0.20, -8.05 {+-} 0.14 and -20.48 {+-} 0.15 kJ mol{sup -1}, obtained for Cu{sup 2+}, Ni{sup 2+} and Co{sup 2+} titrations with C-RUB-xN (x = 1, 3) materials, suggest a favorable process at the solid/liquid interface for inorganic/organic hybrid cation sorptions. These thermodynamic data, expressed also by reaction spontaneity, infer the use of such hybrids for cation removal from aqueous solution.

  2. Tradescantia cytogenetic tests (root-tip mitosis, pollen mitosis, pollen mother-cell meiosis). A report of the US Environmental Protection Agency gene-tox program

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T H

    1982-01-01

    3 kinds of cytogenetic tests for screening of environmental mutagens were established for Tradescantia, namely, root-tip mitosis, pollen mitosis, and pollen mother-cell meiosis (commonly referred to as the Tradescantia-micronucleus (Trad-MCN) test). All these tests are technically simple, inexpensive, and can yield reliable results in a relatively short time (36 to 72 h). The root-tip mitosis test is suitable only for liquid agents, while pollen mitosis is suitable for both liquid and gaseous agents. Pollen tube mitotic chromosomes are extremely sensitive to mutagens; therefore, they are good materials for detecting very low concentrations of mutagens. Both root-tip mitosis and pollen mitosis tests use chromosome and/or chromatid aberrations as end points for scoring. The Trad-MCN test is suitable for both liquid and gaseous agents. In addition, it is especially suitable for in situ monitoring of water and air pollutants. Of the 12 chemicals tested, 5-fluorouracil and 1,2-dibromoethane indicate that they are very potent mutagens based on the effective dosages used to produce a positive response. Sulfur dioxide, ethyl methanesulfonate, sodium azide, Phosdrin, and Bladex rank next in potency.

  3. On the development of a magnetoresistive sensor for blade tip timing and blade tip clearance measurement systems

    Science.gov (United States)

    Tomassini, R.; Rossi, G.; Brouckaert, J.-F.

    2016-10-01

    A simultaneous blade tip timing (BTT) and blade tip clearance (BTC) measurement system enables the determination of turbomachinery blade vibrations and ensures the monitoring of the existing running gaps between the blade tip and the casing. This contactless instrumentation presents several advantages compared to the well-known telemetry system with strain gauges, at the cost of a more complex data processing procedure. The probes used can be optical, capacitive, eddy current as well as microwaves, everyone with its dedicated electronics and many existing different signal processing algorithms. Every company working in this field has developed its own processing method and sensor technology. Hence, repeating the same test with different instrumentations, the answer is often different. Moreover, rarely it is possible to achieve reliability for in-service measurements. Developments are focused on innovative instrumentations and a common standard. This paper focuses on the results achieved using a novel magnetoresistive sensor for simultaneous tip timing and tip clearance measurements. The sensor measurement principle is described. The sensitivity to gap variation is investigated. In terms of measurement of vibrations, experimental investigations were performed at the Air Force Institute of Technology (ITWL, Warsaw, Poland) in a real aeroengine and in the von Karman Institute (VKI) R2 compressor rig. The advantages and limitations of the magnetoresistive probe for turbomachinery testing are highlighted.

  4. Polymer Optical Fiber Compound Parabolic Concentrator fiber tip based glucose sensor: In-Vitro Testing

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Janting, Jakob; Aasmul, Soren

    2016-01-01

    We present in-vitro sensing of glucose using a newly developed efficient optical fiber glucose sensor based on a Compound Parabolic Concentrator (CPC) tipped polymer optical fiber (POF). A batch of 9 CPC tipped POF sensors with a 35 mm fiber length is shown to have an enhanced fluorescence pickup...... efficiency with an average increment factor of 1.7 as compared to standard POF sensors with a plane cut fiber tip. Invitro measurements for two glucose concentrations (40 and 400 mg/dL) confirm that the CPC tipped sensors efficiently can detect both glucose concentrations. it sets the footnote at the bottom...

  5. Axial-Centrifugal Compressor Program

    Science.gov (United States)

    1975-10-01

    Assembly . .. . .... ..... 33 5 Tie Bolt...... .. .. .. .. . *.. .. .. .. .. .. ... 34 6 Axial Compressor Rotor Assembly Runouts . . .. . 34 7 CCV Blow...1.796 Impeller Slip Factor ’Ce2/U 2 ) .91 Impeller Wheel Speed ft/sec 1992.2 Impellet ’.ip Radius in. 3.780 Blade Tip Metal Angle- deg 0 Numbec of Blades...test item to the next Phase V component test. The test vehicle final balance levels and rotor runouts were normal at teardown, and no rubsI were

  6. Dynamic response of a rub-impact rotor system under axial thrust

    Energy Technology Data Exchange (ETDEWEB)

    An, Xueli; Zhou, Jianzhong; Xiang, Xiuqiao; Li, Chaoshun; Luo, Zhimeng [Huazhong University of Science andTechnology, College of Hydroelectric and Digitalization Engineering, Wuhan, Hubei (China)

    2009-11-15

    A model of a rigid rotor system under axial thrust with rotor-to-stator is developed based on the classic impact theory and is analyzed by the Lagrangian dynamics. The rubbing condition is modeled using the elastic impact-contact idealization, which consists of normal and tangential forces at the rotor-to-stator contact point. Mass eccentricity and rotating speed are used as control parameters to simulate the response of rotor system. The motions of periodic, quasi-periodic and chaotic are found in the rotor system response. Mass eccentricity plays an important role in creating chaotic phenomena. (orig.)

  7. Tribological Behavior of Babbitt Alloy Rubbing Against Si3N4 and Steel Under Dry Friction Condition

    Science.gov (United States)

    Ji, Xianbing; Chen, Yinxia

    2016-03-01

    The tribological behavior of Babbitt alloy rubbing with Si3N4 ball and steel ball with various sliding speeds at dry friction condition was investigated. It was found that B88 alloy rubbing with Si3N4 ball and steel ball possesses a low sliding wear resistance at dry friction. The wear rate is above 10-4 mm3/Nm, and the friction coefficient is from 0.2 to 0.4. At low sliding speed of 0.05-0.1 m/s, the mainly wear mechanisms are microgroove and fatigue wear, while at high sliding speed of 0.5 m/s, the wear mechanisms depend on plastic deformation and delamination. The high wear rate indicates that it is needed to prevent Babbitt alloy from working at dry friction conditions, while the low friction coefficient suggests that it is not easy to the occurrence of cold weld.

  8. Turbine-blade tip clearance and tip timing measurements using an optical fiber bundle sensor

    Science.gov (United States)

    Garcia, Iker; Beloki, Josu; Zubia, Joseba; Durana, Gaizka; Aldabaldetreku, Gotzon

    2013-04-01

    Traditional limitations of capacitive, inductive or discharging probe sensor for tip timing and tip clearance measurements are overcome by reflective intensity modulated optical fiber sensors. This paper presents the signals and results corresponding to a one stage turbine rig which rotor has 146 blades, obtained from a transonic wind-tunnel test. The probe is based on a trifurcated bundle of optical fibers that is mounted on turbine casing. It is composed of a central illuminating fiber that guides the light from a laser to the turbine blade, and two concentric rings of receiving fibers that collect the reflected light. Two photodetectors turn this reflected light signal from the receiving rings into voltage. The electrical signals are acquired and saved by a high-sample-rate oscilloscope. In tip clearance calculations the ratio of the signals provided by each ring of receiving fibers is evaluated and translated into distance. In the case of tip timing measurements, only one of the signals is considered to get the arrival time of the blade. The differences between the real and theoretical arrival times of the blades are used to obtain the deflections amplitude. The system provides the travelling wave spectrum, which presents the average vibration amplitude of the blades at a certain nodal diameter. The reliability of the results in the turbine rig testing facilities suggests the possibility of performing these measurements in real turbines under real working conditions.

  9. Epidemiologic Background of Hand Hygiene and Evaluation of the Most Important Agents for Scrubs and Rubs

    Science.gov (United States)

    Kampf, Günter; Kramer, Axel

    2004-01-01

    The etiology of nosocomial infections, the frequency of contaminated hands with the different nosocomial pathogens, and the role of health care workers' hands during outbreaks suggest that a hand hygiene preparation should at least have activity against bacteria, yeasts, and coated viruses. The importance of efficacy in choosing the right hand hygiene product is reflected in the new Centers for Disease Control and Prevention guideline on hand hygiene (J. M. Boyce and D. Pittet, Morb. Mortal. Wkly. Rep. 51:1-45, 2002). The best antimicrobial efficacy can be achieved with ethanol (60 to 85%), isopropanol (60 to 80%), and n-propanol (60 to 80%). The activity is broad and immediate. Ethanol at high concentrations (e.g., 95%) is the most effective treatment against naked viruses, whereas n-propanol seems to be more effective against the resident bacterial flora. The combination of alcohols may have a synergistic effect. The antimicrobial efficacy of chlorhexidine (2 to 4%) and triclosan (1 to 2%) is both lower and slower. Additionally, both agents have a risk of bacterial resistance, which is higher for chlorhexidine than triclosan. Their activity is often supported by the mechanical removal of pathogens during hand washing. Taking the antimicrobial efficacy and the mechanical removal together, they are still less effective than the alcohols. Plain soap and water has the lowest efficacy of all. In the new Centers for Disease Control and Prevention guideline, promotion of alcohol-based hand rubs containing various emollients instead of irritating soaps and detergents is one strategy to reduce skin damage, dryness, and irritation. Irritant contact dermatitis is highest with preparations containing 4% chlorhexidine gluconate, less frequent with nonantimicrobial soaps and preparations containing lower concentrations of chlorhexidine gluconate, and lowest with well-formulated alcohol-based hand rubs containing emollients and other skin conditioners. Too few published data

  10. Standard test method for crack-tip opening displacement (CTOD) fracture toughness measurement

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the determination of critical crack-tip opening displacement (CTOD) values at one or more of several crack extension events, and may be used to measure cleavage crack initiation toughness for materials that exhibit a change from ductile to brittle behavior with decreasing temperature, such as ferritic steels. This test method applies specifically to notched specimens sharpened by fatigue cracking. The recommended specimens are three-point bend [SE(B)], compact [C(T)], or arc-shaped bend [A(B)] specimens. The loading rate is slow and influences of environment (other than temperature) are not covered. The specimens are tested under crosshead or clip gage displacement controlled loading. 1.1.1 The recommended specimen thickness, B, for the SE(B) and C(T) specimens is that of the material in thicknesses intended for an application. For the A(B) specimen, the recommended depth, W, is the wall thickness of the tube or pipe from which the specimen is obtained. Superficial surface machini...

  11. Numerical simulation of the tip aerodynamics and acoustics test

    Science.gov (United States)

    Tejero E, F.; Doerffer, P.; Szulc, O.; Cross, J. L.

    2016-04-01

    The application of an efficient flow control system on helicopter rotor blades may lead to improved aerodynamic performance. Recently, our invention of Rod Vortex Generators (RVGs) has been analyzed for helicopter rotor blades in hover with success. As a step forward, the study has been extended to forward flight conditions. For this reason, a validation of the numerical modelling for a reference helicopter rotor (without flow control) is needed. The article presents a study of the flow-field of the AH-1G helicopter rotor in low-, medium- and high-speed forward flight. The CFD code FLOWer from DLR has proven to be a suitable tool for the aerodynamic analysis of the two-bladed rotor without any artificial wake modelling. It solves the URANS equations with LEA (Linear Explicit Algebraic stress) k-ω model using the chimera overlapping grids technique. Validation of the numerical model uses comparison with the detailed flight test data gathered by Cross J. L. and Watts M. E. during the Tip Aerodynamics and Acoustics Test (TAAT) conducted at NASA in 1981. Satisfactory agreements for all speed regimes and a presence of significant flow separation in high-speed forward flight suggest a possible benefit from the future implementation of RVGs. The numerical results based on the URANS approach are presented not only for a popular, low-speed case commonly used in rotorcraft community for CFD codes validation but preferably for medium- and high-speed test conditions that have not been published to date.

  12. Transcaval TIPS in patients with failed revision of occluded previous TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Seong, Chang Kyu; Kim, Yong Joo; Shin, Tae Beom; Park, Hyo Yong; Kim, Tae Hun; Kang, Duk Sik [Kyungpook National University School of Medicine, Daegu (Korea, Republic of)

    2001-12-01

    To determine the feasibility of transcaval transjugular intrahepatic portosystemic shunt (TIPS) in patients with occluded previous TIPS. Between February 1996 and December 2000 we performed five transcaval TIPS procedures in four patients with recurrent gastric cardiac variceal bleeding. All four had occluded TIPS, which was between the hepatic and portal vein. The interval between initial TIPS placement and revisional procedures with transcaval TIPS varied between three and 31 months; one patient underwent transcaval TIPS twice, with a 31-month interval. After revision of the occluded shunt failed, direct cavoportal puncture at the retrohepatic segment of the IVC was attempted. Transcaval TIPS placement was technically successful in all cases. In three, tractography revealed slight leakage of contrast materials into hepatic subcapsular or subdiaphragmatic pericaval space. There was no evidence of propagation of extravasated contrast materials through the retroperitoneal space or spillage into the peritoneal space. After the tract was dilated by a bare stent, no patient experienced trans-stent bleeding and no serious procedure-related complications occurred. After successful shunt creation, variceal bleeding ceased in all patients. Transcaval TIPS placement is an effective and safe alternative treatment in patients with occluded previous TIPS and no hepatic veins suitable for new TIPS.

  13. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    Science.gov (United States)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  14. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  15. Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

    Science.gov (United States)

    Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.

    2009-01-01

    The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

  16. Hand rub consumption and hand hygiene compliance are not indicators of pathogen transmission in intensive care units.

    NARCIS (Netherlands)

    Eckmanns, T; Schwab, F; Bessert, J; Wettstein, R; Behnke, M; Grundmann, Hajo; Rüden, H; Gastmeier, P

    2006-01-01

    The objective of this study was to investigate whether nosocomial infection (NI) rates, hand hygiene compliance rates and the amount of alcohol-based hand rub used for hand disinfection are useful indicators of pathogen transmission in intensive care units (ICUs), and whether they could be helpful

  17. Aerodynamic effect of a honeycomb rotor tip shroud on a 50.8-centimeter-tip-diameter core turbine

    Science.gov (United States)

    Moffitt, T. P.; Whitney, W. J.

    1983-01-01

    A 50.8-cm-tip-diameter turbine equipped with a rotor tip shroud of hexagonal cell (or honeycomb) cross section has been tested in warm air (416 K) for a range of shroud coolant to primary flow rates. Test results were also obtained for the same turbine operated with a solid shroud for comparison. The results showed that the combined effect of the honeycomb shroud and the coolant flow was to cause a reduction of 2.8 points in efficiency at design speed, pressure ratio, and coolant flow rate. With the coolant system inactivated, the honeycomb shroud caused a decrease in efficiency of 2.3 points. These results and those obtained from a small reference turbine indicate that the dominant factor governing honeycomb tip shroud loss is the ratio of honeycomb depth to blade span. The loss results of the two shrouds could be correlated on this basis. The same honeycomb and coolant effects are expected to occur for the hot (2200 K) version of this turbine.

  18. Influence of heat treatment and indenter tip material on depth sensing hardness tests at high temperatures of fusion relevant materials

    International Nuclear Information System (INIS)

    Bredl, Julian; Dany, Manuel; Albinski, Bartlomiej; Schneider, Hans-Christian; Kraft, Oliver

    2015-01-01

    Highlights: • Operation of a custom-made indentation device designed for test temperatures up to 650 °C and a remote handled operation in a Hot Cell. • Instrumented indentation and conventional hardness testing of unirradiated MANET II and EUROFER. • Comparison of diamond and sapphire as indenter tip materials. - Abstract: The instrumented indentation is a suitable method for testing of even small neutron-irradiated specimens. From the continuously recorded indentation depth and the indentation force, it is possible to deduce mechanical parameters of the tested material. In this paper, a brief description of the high temperature device is given and representative results are presented. In the study, unirradiated steels are investigated by instrumented indentation at temperatures up to 500 °C. It is shown that the hardness is highly depending on the testing-temperature and can be correlated to the results of conventional tensile testing experiments. A not negligible influence of the indenter tip material is observed. The results show the functionality of the high-temperature indentation device.

  19. Influence of heat treatment and indenter tip material on depth sensing hardness tests at high temperatures of fusion relevant materials

    Energy Technology Data Exchange (ETDEWEB)

    Bredl, Julian, E-mail: julian.bredl@kit.edu; Dany, Manuel; Albinski, Bartlomiej; Schneider, Hans-Christian; Kraft, Oliver

    2015-10-15

    Highlights: • Operation of a custom-made indentation device designed for test temperatures up to 650 °C and a remote handled operation in a Hot Cell. • Instrumented indentation and conventional hardness testing of unirradiated MANET II and EUROFER. • Comparison of diamond and sapphire as indenter tip materials. - Abstract: The instrumented indentation is a suitable method for testing of even small neutron-irradiated specimens. From the continuously recorded indentation depth and the indentation force, it is possible to deduce mechanical parameters of the tested material. In this paper, a brief description of the high temperature device is given and representative results are presented. In the study, unirradiated steels are investigated by instrumented indentation at temperatures up to 500 °C. It is shown that the hardness is highly depending on the testing-temperature and can be correlated to the results of conventional tensile testing experiments. A not negligible influence of the indenter tip material is observed. The results show the functionality of the high-temperature indentation device.

  20. Single crystalline growth of a soluble organic semiconductor in a parallel aligned liquid crystal solvent using rubbing-treated polyimide films

    Science.gov (United States)

    Matsuzaki, Tomoya; Shibata, Yosei; Takeda, Risa; Ishinabe, Takahiro; Fujikake, Hideo

    2017-01-01

    For directional control of organic single crystals, we propose a crystal growth method using liquid crystal as the solvent. In this study, we examined the formation of 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT) single crystals using a parallel aligned liquid crystal (LC) cell and rubbing-treated polyimide films in order to clarify the effects of LC alignment on anisotropic C8-BTBT crystal growth. Based on the results, we found that the crystal growth direction of C8-BTBT single crystals was related to the direction of the aligned LC molecules because of rubbing treatment. Moreover, by optical evaluation, we found that the C8-BTBT single crystals have a aligned molecular structure.

  1. Towards easy and reliable AFM tip shape determination using blind tip reconstruction

    International Nuclear Information System (INIS)

    Flater, Erin E.; Zacharakis-Jutz, George E.; Dumba, Braulio G.; White, Isaac A.; Clifford, Charles A.

    2014-01-01

    Quantitative determination of the geometry of an atomic force microscope (AFM) probe tip is critical for robust measurements of the nanoscale properties of surfaces, including accurate measurement of sample features and quantification of tribological characteristics. Blind tip reconstruction, which determines tip shape from an AFM image scan without knowledge of tip or sample shape, was established most notably by Villarrubia [J. Res. Natl. Inst. Stand. Tech. 102 (1997)] and has been further developed since that time. Nevertheless, the implementation of blind tip reconstruction for the general user to produce reliable and consistent estimates of tip shape has been hindered due to ambiguity about how to choose the key input parameters, such as tip matrix size and threshold value, which strongly impact the results of the tip reconstruction. These key parameters are investigated here via Villarrubia's blind tip reconstruction algorithms in which we have added the capability for users to systematically vary the key tip reconstruction parameters, evaluate the set of possible tip reconstructions, and determine the optimal tip reconstruction for a given sample. We demonstrate the capabilities of these algorithms through analysis of a set of simulated AFM images and provide practical guidelines for users of the blind tip reconstruction method. We present a reliable method to choose the threshold parameter corresponding to an optimal reconstructed tip shape for a given image. Specifically, we show that the trend in how the reconstructed tip shape varies with threshold number is so regular that the optimal, or Goldilocks, threshold value corresponds with the peak in the derivative of the RMS difference with respect to the zero threshold curve vs. threshold number. - Highlights: • Blind tip reconstruction algorithms have been implemented and augmented to determine the optimal input parameters. • We demonstrate the capabilities of the algorithms using a simulated AFM

  2. Compressive strength of dental composites photo-activated with different light tips

    International Nuclear Information System (INIS)

    Galvão, M R; Campos, E A; Rastelli, A N S; Andrade, M F; Caldas, S G F R; Calabrez-Filho, S; Bagnato, V S

    2013-01-01

    The aim of this study was to evaluate the compressive strength of microhybrid (Filtek™ Z250) and nanofilled (Filtek™ Supreme XT) composite resins photo-activated with two different light guide tips, fiber optic and polymer, coupled with one LED. The power density was 653 mW cm −2 when using the fiber optic light tip and 596 mW cm −2 with the polymer. After storage in distilled water at 37 ± 2 °C for seven days, the samples were subjected to mechanical testing of compressive strength in an EMIC universal mechanical testing machine with a load cell of 5 kN and speed of 0.5 mm min −1 . The statistical analysis was performed using ANOVA with a confidence interval of 95% and Tamhane’s test. The results showed that the mean values of compressive strength were not influenced by the different light tips (p > 0.05). However, a statistical difference was observed (p < 0.001) between the microhybrid composite resin photo-activated with the fiber optic light tip and the nanofilled composite resin. Based on these results, it can be concluded that microhybrid composite resin photo-activated with the fiber optic light tip showed better results than nanofilled, regardless of the tip used, and the type of the light tip did not influence the compressive strength of either composite. Thus, the presented results suggest that both the fiber optic and polymer light guide tips provide adequate compressive strength to be used to make restorations. However, the fiber optic light tip associated with microhybrid composite resin may be an interesting option for restorations mainly in posterior teeth. (paper)

  3. Implementation and testing of the travel time prediction system (TIPS)

    OpenAIRE

    PANT, Prahlad D; UNIVERSITY OF CINCINNATI

    2001-01-01

    RAPPORT DE RECHERCHE FINAL The Travel Time Prediction System (TIPS) is a portable automated system for predicting and displaying travel time for motorists in advance of and through freeway construction work zones,on a real-time basis

  4. In Small Animal Surgery Are Alcoholic Hand Rubs Superior to Scrubbing Brushes and Antimicrobial Soap at Reducing Bacterial Counts?

    Directory of Open Access Journals (Sweden)

    Alison Claire Mann

    2016-10-01

    Full Text Available Clinical bottom lineThe current literature suggests that the use of alcohol hand rubs provide similar, if not better, reductions in bacteria colony forming units, both immediately after hand antisepsis and in the immediate postoperative period.

  5. Thulium fiber laser lithotripsy using a muzzle brake fiber tip

    Science.gov (United States)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-02-01

    The Thulium fiber laser (TFL) is being explored as an alternative to Holmium:YAG laser for lithotripsy. TFL beam profile allows coupling of higher power into smaller fibers than multimode Holmium laser beam, without proximal fiber tip degradation. A smaller fiber provides more space in ureteroscope working channel for increased saline irrigation and allows maximum ureteroscope flexion. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback, but increased retropulsion. In this study, a "fiber muzzle brake" was tested for reducing fiber burnback and stone retropulsion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-OD, 360-μm-ID tube with 275-μm thru hole located 250-μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed, ex vivo. Small stones with a mass of 40 +/- 4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25 +/- 4 s (n=10), without distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers. The muzzle brake fiber tip provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  6. Proton MR spectroscopy of the brain in patients treated with tips

    Energy Technology Data Exchange (ETDEWEB)

    Hamuro, M.; Nakamura, K.; Matsuoka, T.; Kaminou, T.; Higashida, M.; Yamada, R. [Osaka City Univ. Medical School (Japan). Dept. of Radiology

    2000-11-01

    To evaluate the utility of proton MR spectroscopy (MRS) for the early detection of hepatic encephalopathy (HE) after transjugular intrahepatic portosystemic shunting (TIPS). Material and Methods: Six patients, who underwent TIPS for treatment of portal hypertension, were examined by MRS 1 week before and 1 week after TIPS. They were simultaneously clinically examined for number connection test, blood NH{sub 3} level, liver function test and the Fischer ratio. Result: Three of 6 patients showed overt HE 1 to 5 weeks after TIPS and the other 3 patients did not show overt HE. The overt HE group showed the larger ratio of the amounts of glutamine and glutamate/myoinositol (Glx/MI) than that of non-overt HE group (p<0.05). Conclusion: The Glx/MI ratio estimated by MRS was useful for early detection of HE after TIPS.

  7. Proton MR spectroscopy of the brain in patients treated with tips

    International Nuclear Information System (INIS)

    Hamuro, M.; Nakamura, K.; Matsuoka, T.; Kaminou, T.; Higashida, M.; Yamada, R.

    2000-01-01

    To evaluate the utility of proton MR spectroscopy (MRS) for the early detection of hepatic encephalopathy (HE) after transjugular intrahepatic portosystemic shunting (TIPS). Material and Methods: Six patients, who underwent TIPS for treatment of portal hypertension, were examined by MRS 1 week before and 1 week after TIPS. They were simultaneously clinically examined for number connection test, blood NH 3 level, liver function test and the Fischer ratio. Result: Three of 6 patients showed overt HE 1 to 5 weeks after TIPS and the other 3 patients did not show overt HE. The overt HE group showed the larger ratio of the amounts of glutamine and glutamate/myoinositol (Glx/MI) than that of non-overt HE group (p<0.05). Conclusion: The Glx/MI ratio estimated by MRS was useful for early detection of HE after TIPS

  8. Phacoemulsification tip vacuum pressure: Comparison of 4 devices.

    Science.gov (United States)

    Payne, Marielle; Georgescu, Dan; Waite, Aaron N; Olson, Randall J

    2006-08-01

    To determine the vacuum pressure generated by 4 phacoemulsification devices measured at the phacoemulsification tip. University ophthalmology department. The effective vacuum pressures generated by the Sovereign (AMO), Millennium (Bausch & Lomb), Legacy AdvanTec (Alcon Laboratories), and Infiniti (Alcon Laboratories) phacoemulsification machines were measured with a device that isolated the phacoemulsification tip in a chamber connected to a pressure gauge. The 4 machines were tested at multiple vacuum limit settings, and the values were recorded after the foot pedal was fully depressed and the pressure had stabilized. The AdvanTec and Infiniti machines were tested with and without occlusion of the Aspiration Bypass System (ABS) side port (Alcon Laboratories). The Millennium machine was tested using venturi and peristaltic pumps. The machines generated pressures close to the expected at maximum vacuum settings between 100 mm Hg and 500 mm Hg with few intermachine variations. There was no significant difference between pressures generated using 19- or 20-gauge tips (Millennium and Sovereign). The addition of an ABS side port decreased vacuum by a mean of 12.1% (P < .0001). Although there were some variations in vacuum pressures among phacoemulsification machines, particularly when an aspiration bypass tip was used, these discrepancies are probably not clinically significant.

  9. Behavior of Fatigue Crack Tip Opening in Air and Corrosive Atmosphere

    Science.gov (United States)

    Hayashi, Morihito; Toeda, Kazunori

    In the study, a formula for predicting fatigue crack tip opening displacement is deduced firstly. And then, due to comparing actual crack growth rate with the deduced formula, the crack tip configuration factor is defined to figure out the crack tip opening configuration that is useful to clarify the behavior of fatigue crack tip formation apparently. Applying the concept, the crack growth of 7/3 brass and 6/4 brass is predicted from the formula, by replacing material properties such as plastic flow resistance, Young modulus, the Poisson ratio, and fatigue toughness, and fatigue test conditions such as the stress intensity factor range, the load ratio, and cycle frequency. Furthermore, the theoretically expected results are verified with the fatigue tests which were carried out on CT specimens under different load conditions of load ratio, cycle frequency, and cyclic peak load, in different environments of air or corrosive ammonia atmosphere, for various brasses. And by comparing and discussing the calculated crack growth rate with attained experimental results, the apparent configuration factor at the crack tip is determined. And through the attained factor which changes along with crack growth, the behaviors of fatigue crack tip formation under different test conditions have been found out.

  10. Tests of Full-Scale Helicopter Rotors at High Advancing Tip Mach Numbers and Advance Ratios

    Science.gov (United States)

    Biggers, James C.; McCloud, John L., III; Stroub, Robert H.

    2015-01-01

    As a continuation of the studies of reference 1, three full-scale helicopter rotors have been tested in the Ames Research Center 40- by SO-foot wind tunnel. All three of them were two-bladed, teetering rotors. One of the rotors incorporated the NACA 0012 airfoil section over the entire length of the blade. This rotor was tested at advance ratios up to 1.05. Both of the other rotors were tapered in thickness and incorporated leading-edge camber over the outer 20 percent of the blade radius. The larger of these rotors was tested at advancing tip Mach numbers up to 1.02. Data were obtained for a wide range of lift and propulsive force, and are presented without discussion.

  11. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    Science.gov (United States)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  12. "Fan-Tip-Drive" High-Power-Density, Permanent Magnet Electric Motor and Test Rig Designed for a Nonpolluting Aircraft Propulsion Program

    Science.gov (United States)

    Brown, Gerald V.; Kascak, Albert F.

    2004-01-01

    A scaled blade-tip-drive test rig was designed at the NASA Glenn Research Center. The rig is a scaled version of a direct-current brushless motor that would be located in the shroud of a thrust fan. This geometry is very attractive since the allowable speed of the armature is approximately the speed of the blade tips (Mach 1 or 1100 ft/s). The magnetic pressure generated in the motor acts over a large area and, thus, produces a large force or torque. This large force multiplied by the large velocity results in a high-power-density motor.

  13. Aspectos laboratoriais e epidemiológicos de infecções por rubéola na cidade Rio de Janeiro

    Directory of Open Access Journals (Sweden)

    Rita Maria R. Nogueira

    1976-06-01

    Full Text Available Os autores apresentam dados obtidos no estudo de soros com a finalidade de determinar os níveis de anticorpos para rubéola, no período de 1970 a 1975, na cidade do Rio de Janeiro. Estes soros induiram principalmente gestantes em contato com casos clínicos ou suspeitos de rubéola. Dentre as gestantes, de 2.155 casos em que as informações eram mais completas, analisaram-se os resultados da sorologia com a finalidade de estabelecer o grau de imunidade prévio ao contato e o nível de risco para o concepto. Verificou-se que 84,4% destas gestantes possuiam anticorpos, sendo que destas 8,1% alcançaram níveis iguais ou superiores a 1/320, sugerint infecção recente. Obteve-se conversão sorológica em 1,2%, comprovando-se a infecção atual por rubéola. A análise dos dados referentes a casos notificados de rubéola na cidade do Rio de Janeiro no período de 1965 a 1974 demonstrou uma incidência maior no segundo semestre, tendo ocorrido dois surtos da doença, um em 1968 e outro em 1974.The authors present data obtained from the study of sera in order to determine antibody leveis for rubella in Rio de Janeiro city, during the period 1970/1975. These sera induded mainly pregnant women having had contact with suspect and clinically defined cases of the disease. Among the group studies, 2155 cases of pregnants which had more complete data were analized with the purpose of stablishing immunity degree before contact and risk levei for the concept. It was found that 84,4% of these pregnants had rubella circulating antibodies and 8,1% of them reached leveis equal or more than 1/320, suggestive of recent infection. Serologic conversion was obtained in 1,2%, firming present infection. Analysis of data refering to notified cases of rubella during the period from 1965 to 1974 showa greater incidence during the secondsemester, as well as two outbreaks of the disease which had occurred in 1968 and in 1974.

  14. Influence of the tip mass on the tip-sample interactions in TM-AFM

    Energy Technology Data Exchange (ETDEWEB)

    Pishkenari, Hossein Nejat, E-mail: nejat@mech.sharif.edu [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of); Meghdari, Ali [Nano-Robotics Laboratory, Center of Excellence in Design, Robotics and Automation, School of Mechanical Engineering, Sharif University of Technology, Tehran, P.O. Box 11365-9465 (Iran, Islamic Republic of)

    2011-07-15

    This paper focuses on the influences of the tip mass ratio (the ratio of the tip mass to the cantilever mass), on the excitation of higher oscillation eigenmodes and also on the tip-sample interaction forces in tapping mode atomic force microscopy (TM-AFM). A precise model for the cantilever dynamics capable of accurate simulations is essential for the investigation of the tip mass effects on the interaction forces. In the present work, the finite element method (FEM) is used for modeling the AFM cantilever to consider the oscillations of higher eigenmodes oscillations. In addition, molecular dynamics (MD) is used to calculate precise data for the tip-sample force as a function of tip vertical position with respect to the sample. The results demonstrate that in the presence of nonlinear tip-sample interaction forces, the tip mass ratio plays a significant role in the excitations of higher eigenmodes and also in the normal force applied on the surface. Furthermore, it has been shown that the difference between responses of the FEM and point-mass models in different system operational conditions is highly affected by the tip mass ratio. -- Highlights: {yields} A strong correlation exists between the tip mass ratio and the 18th harmonic amplitude. {yields} Near the critical tip mass ratio a small change in the tip mass may lead to a significant force change. {yields} Inaccuracy of the lumped model depends significantly on the tip mass ratio.

  15. Establishment of an efficient virus-induced gene silencing (VIGS) assay in Arabidopsis by Agrobacterium-mediated rubbing infection.

    Science.gov (United States)

    Manhães, Ana Marcia E de A; de Oliveira, Marcos V V; Shan, Libo

    2015-01-01

    Several VIGS protocols have been established for high-throughput functional genomic screens as it bypasses the time-consuming and laborious process of generation of transgenic plants. The silencing efficiency in this approach is largely hindered by a technically demanding step in which the first pair of newly emerged true leaves at the 2-week-old stage are infiltrated with a needleless syringe. To further optimize VIGS efficiency and achieve rapid inoculation for a large-scale functional genomic study, here we describe a protocol of an efficient VIGS assay in Arabidopsis using Agrobacterium-mediated rubbing infection. The Agrobacterium inoculation is performed by simply rubbing the leaves with Filter Agent Celite(®) 545. The highly efficient and uniform silencing effect was indicated by the development of a visibly albino phenotype due to silencing of the Cloroplastos alterados 1 (CLA1) gene in the newly emerged leaves. In addition, the albino phenotype could be observed in stems and flowers, indicating its potential application for gene functional studies in the late vegetative development and flowering stages.

  16. Vibration characteristics of a hydraulic generator unit rotor system with parallel misalignment and rub-impact

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zhiwei; Zhou, Jianzhong; Yang, Mengqi; Zhang, Yongchuan [Huazhong University of Science and Technology, College of Hydraulic and Digitalization Engineering, Wuhan, Hubei Province (China)

    2011-07-15

    The object of this research aims at the hydraulic generator unit rotor system. According to fault problems of the generator rotor local rubbing caused by the parallel misalignment and mass eccentricity, a dynamic model for the rotor system coupled with misalignment and rub-impact is established. The dynamic behaviors of this system are investigated using numerical integral method, as the parallel misalignment, mass eccentricity and bearing stiffness vary. The nonlinear dynamic responses of the generator rotor and turbine rotor with coupling faults are analyzed by means of bifurcation diagrams, Poincare maps, axis orbits, time histories and amplitude spectrum diagrams. Various nonlinear phenomena in the system, such as periodic, three-periodic and quasi-periodic motions, are studied with the change of the parallel misalignment. The results reveal that vibration characteristics of the rotor system with coupling faults are extremely complex and there are some low frequencies with large amplitude in the 0.3-0.4 x components. As the increase in mass eccentricity, the interval of nonperiodic motions will be continuously moved forward. It suggests that the reduction in mass eccentricity or increase in bearing stiffness could preclude nonlinear vibration. These might provide some important theory references for safety operating and exact identification of the faults in rotating machinery. (orig.)

  17. Secondary Angle Closure due to Crystalline Lens Dislocation in a Patient with Atopic Dermatitis and Chronic Eye Rubbing

    Directory of Open Access Journals (Sweden)

    Justin Kuiper

    2018-03-01

    Full Text Available Purpose: To report an unusual case of ectopia lentis and angle closure in a patient with chronic eye rubbing. Methods: A 57-year-old male with a history of poorly controlled atopic dermatitis presented with right eye pain, decreased vision, and an intraocular pressure (IOP of 55 mm Hg. He had no past history of ocular disease and no reported history of trauma. He did report a history of chronic eye rubbing. Results: Best corrected visual acuity was hand motions. The examination revealed severe atopic keratoconjunctivitis in both eyes, microcystic corneal edema of the right eye, and 2+ nuclear sclerosis in both eyes. Gonioscopy showed no visible angle structures OD and an open angle OS. Topical and oral IOP-lowering medications and a laser iridotomy were unsuccessful at lowering IOP. He was taken to the operating room for a lensectomy and was found to have 9 clock hours of zonular dehiscence and a dislocated lens. After lensectomy, the IOP improved to 9 mm Hg on postoperative day 1. A follow-up examination at 2 weeks showed improved acuity to 20/150 with a pinhole and an IOP of 10 mm Hg. A dilated examination OS did not reveal significant phacodonesis, and the patient was referred for a possible sutured sulcus lens or anterior chamber intraocular lens. Conclusions: It is important for the provider to consider ectopia lentis in the differential for patients with pupillary block angle closure. For patients with atopic disease, one should be aware that eye rubbing may be a cause of zonular dehiscence, even in the absence of reported trauma or prior intraocular surgery.

  18. DO SLOVENIAN DEALERS USE TECHNIQUES FOR INCREASING THEIR TIPS?

    Directory of Open Access Journals (Sweden)

    Andrej Raspor

    2016-05-01

    Full Text Available In 1996 Michael Lynn introduced the idea that restaurant managers could increase tips for their waiters and thus increase turnover by training the waiters to engage tip-enhancing behaviours. Since then, the list of tip-enhancing behaviours has expanded. Therefore the potential to increase tips is more accessible. The purpose of this paper was to examine how Slovenian dealers use strategies to increase their tips. We tested fourteen techniques to increase tips. The study was carried out among 473 gaming employees, 279 of which are dealers, in the Slovenian gaming industry, in order to find out how they use these techniques and which of them can bring about an increase in their tips. The study showed that Slovenian dealers mostly do not use these techniques, and that the dealers who do use them tend to receive tips more often. The findings imply that managers and employees should be informed of these techniques in order to increase tips and their overall income. Practical implications are that we suggest that management considers these ideas for increasing flexibility and reducing the cost of work: (1 informing dealers on ways of increasing tips, (2 including the acquisition of this specific knowledge in their career plans, (3 carrying out a reform of the reward system which would include tips. Social implications will be shown in a higher gaming revenue. It is very likely – as shown in our research – that employees will receive higher wages as these will be topped up by tips. The state, in turn, will collect more taxes.

  19. Kaplan turbine tip vortex cavitation - analysis and prevention

    Science.gov (United States)

    Motycak, L.; Skotak, A.; Kupcik, R.

    2012-11-01

    The work is focused on one type of Kaplan turbine runner cavitation - a tip vortex cavitation. For detailed description of the tip vortex, the CFD analysis is used. On the basis of this analysis it is possible to estimate the intensity of cavitating vortex core, danger of possible blade surface and runner chamber cavitation pitting. In the paper, the ways how to avoid the pitting effect of the tip vortex are described. In order to prevent the blade surface against pitting, the following possibilities as the change of geometry of the runner blade, dimension of tip clearance and finally the installation of the anti-cavitation lips are discussed. The knowledge of the shape and intensity of the tip vortex helps to design the anti-cavitation lips more sophistically. After all, the results of the model tests of the Kaplan runner with or without anti-cavitation lips and the results of the CFD analysis are compared.

  20. Presencia de anticuerpos IgG del virus de la rubéola, virus herpes simple y citomegalovirus en embarazadas residentes en Ciudad de La Habana

    Directory of Open Access Journals (Sweden)

    Carmen Acosta

    2001-06-01

    Full Text Available Se realizó un estudio seroepidemiológico con 207 gestantes, residentes en el municipio Marianao de Ciudad de la Habana, con la finalidad de conocer la presencia de anticuerpos IgG anti-rubéola, anti-citomegalovirus y anti-herpes simple (1 y 2; el nivel de positividad se expresó como la relación de la fluorescencia de la muestra con respecto a la del control positivo, para un nivel de corte de 0,3 para rubéola, 0,2 para citomegalovirus y 0,185 para herpes simple. Las seroconversiones se expresaron como el incremento de esta relación con respecto a la determinación realizada en el primer trimestre de embarazo. El 91,3% de las gestantes resultaron positivas para rubéola, el 92,7% para citomegalovirus y el 98,1% para herpes simple. Se sugiere la valoración de aspectos fundamentales relacionados con estas infecciones dentro del Programa Nacional de Atención a las Embarazadas.

  1. Tipping Point

    Medline Plus

    Full Text Available ... death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ... tv tip-overs. The force of a large television falling from tipping furniture can be staggering. A ...

  2. Tipping Point

    Medline Plus

    Full Text Available ... and furniture, appliance and tv tip-overs. The force of a large television falling from tipping furniture ... 50 lb. TV falls with about the same force as child falling from the third story of ...

  3. Tipping Point

    Medline Plus

    Full Text Available ... Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture ... about horrible accidents involving young children and furniture, appliance and tv tip-overs. The force of a ...

  4. Numerical analysis of turbine blade tip treatments

    Science.gov (United States)

    Gopalaswamy, Nath S.; Whitaker, Kevin W.

    1992-01-01

    Three-dimensional solutions of the Navier-Stokes equations for a turbine blade with a turning angle of 180 degrees have been computed, including blade tip treatments involving cavities. The geometry approximates a preliminary design for the GGOT (Generic Gas Oxidizer Turbine). The data presented here will be compared with experimental data to be obtained from a linear cascade using original GGOT blades. Results have been computed for a blade with 1 percent clearance, based on chord, and three different cavity sizes. All tests were conducted at a Reynolds number of 4 x 10 exp 7. The grid contains 39,440 points with 10 spanwise planes in the tip clearance region of 5.008E-04 m. Streamline plots and velocity vectors together with velocity divergence plots reveal the general flow behavior in the clearance region. Blade tip temperature calculations suggest placement of a cavity close to the upstream side of the blade tip for reduction of overall blade tip temperature. The solutions do not account for the relative motion between the endwall and the turbine blade. The solutions obtained are generally consistent with previous work done in this area,

  5. Tips for TIPS

    NARCIS (Netherlands)

    Cuijpers, C.F.

    2015-01-01

    The transjugular intrahepatic portosystemic shunt (TIPS) procedure is one of the most technically challenging procedures in interventional radiology. During the procedure, interventional radiologists (IRs) insert very thin and long instruments through a little incision in the patient’s neck. They

  6. CPAP Tips

    Science.gov (United States)

    ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  7. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  8. CPAP Tips

    Medline Plus

    Full Text Available ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  9. Tipping Point

    Medline Plus

    Full Text Available ... 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash ...

  10. DEFORMATION INFLUENCE ON A LIFETIME OF WELDING ELECTRODE TIPS

    Directory of Open Access Journals (Sweden)

    Ján Viňáš

    2009-02-01

    Full Text Available The contribution deals with the influence of welding electrode tips deformation on their lifetime. The influence of material properties, production technology and the intensity of welding electrodes load on their lifetime are presented. The electrode tips of the most used type of CuCr1Zr alloy of three basic standard shapes before and after the process of welding are evaluated. The process of welding is realized with low, middle and maximum welding parameters on programmable pneumatic spot welding machine VTS BPK 20. The influence of welding parameters on chosen material characteristics of welding tips is observed. Through the use of upsetting test, dependency of forming strength and deformation of material on used technology of welding tip production is observed.

  11. The tipping point: A mathematical model for the profit-driven abandonment of restaurant tipping

    Science.gov (United States)

    Clifton, Sara M.; Herbers, Eileen; Chen, Jack; Abrams, Daniel M.

    2018-02-01

    The custom of voluntarily tipping for services rendered has gone in and out of fashion in America since its introduction in the 19th century. Restaurant owners that ban tipping in their establishments often claim that social justice drives their decisions, but we show that rational profit-maximization may also justify the decisions. Here, we propose a conceptual model of restaurant competition for staff and customers, and we show that there exists a critical conventional tip rate at which restaurant owners should eliminate tipping to maximize profits. Because the conventional tip rate has been increasing steadily for the last several decades, our model suggests that restaurant owners may abandon tipping en masse when that critical tip rate is reached.

  12. Kaplan turbine tip vortex cavitation – analysis and prevention

    International Nuclear Information System (INIS)

    Motycak, L; Skotak, A; Kupcik, R

    2012-01-01

    The work is focused on one type of Kaplan turbine runner cavitation – a tip vortex cavitation. For detailed description of the tip vortex, the CFD analysis is used. On the basis of this analysis it is possible to estimate the intensity of cavitating vortex core, danger of possible blade surface and runner chamber cavitation pitting. In the paper, the ways how to avoid the pitting effect of the tip vortex are described. In order to prevent the blade surface against pitting, the following possibilities as the change of geometry of the runner blade, dimension of tip clearance and finally the installation of the anti-cavitation lips are discussed. The knowledge of the shape and intensity of the tip vortex helps to design the anti-cavitation lips more sophistically. After all, the results of the model tests of the Kaplan runner with or without anti-cavitation lips and the results of the CFD analysis are compared.

  13. Energy efficient engine high pressure turbine test hardware detailed design report

    Science.gov (United States)

    Halila, E. E.; Lenahan, D. T.; Thomas, T. T.

    1982-01-01

    The high pressure turbine configuration for the Energy Efficient Engine is built around a two-stage design system. Moderate aerodynamic loading for both stages is used to achieve the high level of turbine efficiency. Flowpath components are designed for 18,000 hours of life, while the static and rotating structures are designed for 36,000 hours of engine operation. Both stages of turbine blades and vanes are air-cooled incorporating advanced state of the art in cooling technology. Direct solidification (DS) alloys are used for blades and one stage of vanes, and an oxide dispersion system (ODS) alloy is used for the Stage 1 nozzle airfoils. Ceramic shrouds are used as the material composition for the Stage 1 shroud. An active clearance control (ACC) system is used to control the blade tip to shroud clearances for both stages. Fan air is used to impinge on the shroud casing support rings, thereby controlling the growth rate of the shroud. This procedure allows close clearance control while minimizing blade tip to shroud rubs.

  14. Bent versus straight tips in micropulsed longitudinal phacoemulsification.

    Science.gov (United States)

    Stagg, Brian C; Gupta, Isha; Cahoon, Judd; Ronquillo, Cecinio; Shi, Dallas; Zaugg, Brian; Gardiner, Gareth; Barlow, William R; Pettey, Jeff H; Aabid Farukhi, M; Jensen, Jason; Olson, Randall J

    2015-10-01

    The aim of this study was to evaluate bent and straight phacoemulsification tips to determine which tip is more efficient in removal of lens fragments, using micropulsed longitudinal ultrasound in phacoemulsification. In vitro laboratory study. The John A. Moran Eye Center Laboratories, University of Utah, Salt Lake City, Utah, was the study setting. Pig lenses hardened in a manner comparable with dense human cataracts were cut into 2-mm cubes and removed with micropulsed longitudinal ultrasound using settings previously shown to be optimally efficient (6 milliseconds on and 6 milliseconds off for a bent tip). To verify this time as most efficient for a straight tip, we also tested times of 5, 6, and 7 milliseconds time on and off. The tips were either straight or with a 20-degree bend. Twenty cubes were used for each comparative run. For the straight tip, 6 milliseconds on (1.56 ± 0.815 seconds) was significantly more efficient than 7 milliseconds on (2.45 ± 1.56 seconds, p = 0.001) and not significantly more efficient than 5 milliseconds on (1.69 ± 0.86 seconds, p = 0.43). Five milliseconds off time (1.45 ± 0.76s) was more efficient than 6 milliseconds (2.06 ± 1.37 seconds, p = 0.004) and 7 milliseconds off (2.18 ± 1.24s, p = 0.001). The straight tip was more efficient than the bent tip (1.38 ± 0.83 versus 2.93 ± 2.14 seconds, p = 0.006). Results are contrary to accepted common belief. Micropulsed longitudinal phacoemulsification is more efficient with a straight rather than a bent tip. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  15. Technology Tips

    Science.gov (United States)

    Mathematics Teacher, 2004

    2004-01-01

    Some inexpensive or free ways that enable to capture and use images in work are mentioned. The first tip demonstrates the methods of using some of the built-in capabilities of the Macintosh and Windows-based PC operating systems, and the second tip describes methods to capture and create images using SnagIt.

  16. Nanobits - exchangable and customisable scanning probe tips

    DEFF Research Database (Denmark)

    Yildiz, Izzet

    dimensions: tips suitable for imaging high-aspect ratio structures and sidewall profiles were designed. Tip diameters in the order of 30 nm were reproducibly obtained with the FIB milling and the smallest tip diameter achieved was ... process by providing direct picking up of the NanoBits by the AFM probe was investigated. Two different bending mechanisms were studied for out-of-plane bending studies: FIB irradiation- and the residual stress-driven bending in bimorph structures. With FIB irradiation studies, NanoBits were demonstrated...... of the structure which may be starting at 170°C. The fabricated NanoBits were assembled and their performance as AFM probes were tested at OFFIS. The NanoBits were successfully picked up by a microgripper, collected in a cartridge and mounted to an AFM probe. Performances of the assembled high-aspect-ratio Nano...

  17. The TIPS Liquidity Premium

    DEFF Research Database (Denmark)

    Andreasen, Martin Møller; Christensen, Jens H.E.; Simon Riddell, Simon

    We introduce an arbitrage-free term structure model of nominal and real yields that accounts for liquidity risk in Treasury inflation-protected securities (TIPS). The novel feature of our model is to identify liquidity risk from individual TIPS prices by accounting for the tendency that TIPS, lik...

  18. Novel cylindrical illuminator tip for ultraviolet light delivery

    Science.gov (United States)

    Shangguan, HanQun; Haw, Thomas E.; Gregory, Kenton W.; Casperson, Lee W.

    1993-06-01

    The design, processing, and sequential testing of a novel cylindrical diffusing optical fiber tip for ultraviolet light delivery is described. This device has been shown to uniformly (+/- 15%) illuminate angioplasty balloons, 20 mm in length, that are used in an experimental photochemotherapeutic treatment of swine intimal hyperplasia. Our experiments show that uniform diffusing tips of epoxy mixed with Al2O3 powder. To improve the uniformity and ease of fabrication, we have evaluated a new device configuration where the tip is etched into a modified conical shape, and the distal end face is polished and then coated with an optically opaque epoxy. This is shown to uniformly scatter approximately 70% of the light launched into the fiber without forward transmission.

  19. Plastic spatula with narrow long tip provides higher satisfactory smears for Pap test.

    Science.gov (United States)

    Kaur, Pervinder; Kushtagi, Pralhad

    2013-07-01

    Ayre spatula for cervical smear collection is being used despite the suggestion that different modified spatulas provide more satisfactory sampling. To see whether the cytological pickup improves with the use of long tipped spatula. Rurally based University Hospital; crossover study. Pap smear using Ayre spatula in 500 and with plastic narrow long tip (Szalay) spatula in 500 clinic attending women was taken and analyzed. Crossover smears were taken with modified spatula in 163 and using Ayre spatula in 187 women after 2 weeks of initial smears. The same pathologist made cytological reporting for all smears and was unaware of the type of spatula used. Smears from Ayre spatula had significantly higher reports of inadequate smears (94 of 500 vs. 68 of 500 for Ayre and Szalay, respectively; P = 0.032) and it remained so even after crossover (94 of 187 vs. 70 of 163 for Ayre and Szalay, respectively; P = 0.2). Cellular quality appeared better with smears taken using Szalay spatula, but the overall abnormal smear detection rate remained similar with either collection tool (χ(2) = 1.5; P = 0.2). Proportion of satisfactory smears is higher when long tip plastic spatula is used for collection of sample.

  20. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  1. CFD Analysis of Scale Effects on Conventional and Tip-Modified Propellers

    DEFF Research Database (Denmark)

    Shin, Keun Woo; Andersen, Poul

    2017-01-01

    Full-scale propeller performance is traditionally predictedby scaling model-scale test results, but the traditionalscaling methods do not take into account hydrodynamicdistinctions of tip-modified propellers in full-scaleperformance. An open-water CFD analysis is made onscale effects of tip...... the transition model shows that laminar and transitionalflow modeling is crucial in model-scale computations.Grid-independent solutions at model and full scale areachieved by grid verification studies. The CFD analysis of scale effects shows that theefficiency gain of the tip-modified propeller is increasedat...

  2. Anafilaxia associada à vacina contra sarampo, caxumba e rubéola Anafilaxia asociada a la vacuna contra sarampión, varicela y rubéola Anaphylaxis associated with the vaccine against measles, mumps and rubella

    Directory of Open Access Journals (Sweden)

    Iolanda Maria Novadzki

    2010-04-01

    Full Text Available Estudo do tipo caso-controle cujo objetivo foi descrever os casos e as causas de anafilaxia associada à vacina contra sarampo, caxumba e rubéola. Foram estudados 22 casos notificados em crianças de Curitiba, PR, durante Campanha Nacional de Vacinação de 2004, que apresentaram manifestações mucocutâneas. Para o controle, foram selecionadas 66 crianças vizinhas dos casos, que não apresentaram sintomatologia após a aplicação vacinal. Foram realizadas dosagens séricas de anticorpos para os antígenos vacinais, IgE total e específicas para diversos alérgenos, e testes cutâneos. A resposta vacinal foi adequada, a dosagem de IgE específica e os testes cutâneos mostraram que os alérgenos potenciais constituintes da vacina e a atopia não foram relacionados às reações anafiláticas. Os testes cutâneos com a vacina e o dextrano foram positivos somente nos casos, sugerindo sensibilização por algum componente residual da vacina e possível reação cruzada com o dextrano.Estudio del tipo caso-control cuyo objetivo fue describir los casos y las causas de anafilaxia asociada a la vacuna contra sarampión, varicela y rubéola. Fueron estudiados 22 casos notificados en niños de Curitiba, Sureste de Brasil, durante Campaña Nacional de Vacunación de 2004, que presentaron manifestaciones mococutáneas. Para el control, fueron seleccionados 66 niños vecinos de los casos, que no presentaron sintomatología posterior a la aplicación vacunal. Fueron realizadas dosificaciones séricas de anticuerpos para los antígenos vacunales, IgE total y específicas para diversos alérgenos, y pruebas cutáneas. La respuesta vacunal fue adecuada, la dosificación de IgE específica y las pruebas cutáneas mostraron que los alérgenos potenciales constituyentes de la vacuna y la atopia no fueron relacionados a las reacciones anafilácticas. Las pruebas cutáneas con la vacuna y el dextrano fueron positivas solamente en los casos, sugiriendo

  3. Diabetes Prevention: 5 Tips for Taking Control

    Science.gov (United States)

    ... Consider the latest diabetes prevention tips from the American Diabetes Association. There are many benefits to regular physical activity. ... if diabetes testing is appropriate for you. The American Diabetes Association recommends blood glucose screening if: You're age ...

  4. Neural network approximation of tip-abrasion effects in AFM imaging

    International Nuclear Information System (INIS)

    Bakucz, Peter; Dziomba, Thorsten; Koenders, Ludger; Krüger-Sehm, Rolf; Yacoot, Andrew

    2008-01-01

    The abrasion (wear) of tips used in scanning force microscopy (SFM) directly influences SFM image quality and is therefore of great relevance to quantitative SFM measurements. The increasing implementation of automated SFM measurement schemes has become a strong driving force for increasing efforts towards the prediction of tip wear, as it needs to be ensured that the probe is exchanged before a level of tip wear is reached that adversely affects the measurement quality. In this paper, we describe the identification of tip abrasion in a system of SFM measurements. We attempt to model the tip-abrasion process as a concatenation of a mapping from the measured AFM data to a regression vector and a nonlinear mapping from the regressor space to the output space. The mapping is formed as a basis function expansion. Feedforward neural networks are used to approximate this mapping. The one-hidden layer network gave a good quality of fit for the training and test sets for the tip-abrasion system. We illustrate our method with AFM measurements of both fine periodic structures and randomly oriented sharp features and compare our neural network results with those obtained using other methods

  5. Neural network approximation of tip-abrasion effects in AFM imaging

    Science.gov (United States)

    Bakucz, Peter; Yacoot, Andrew; Dziomba, Thorsten; Koenders, Ludger; Krüger-Sehm, Rolf

    2008-06-01

    The abrasion (wear) of tips used in scanning force microscopy (SFM) directly influences SFM image quality and is therefore of great relevance to quantitative SFM measurements. The increasing implementation of automated SFM measurement schemes has become a strong driving force for increasing efforts towards the prediction of tip wear, as it needs to be ensured that the probe is exchanged before a level of tip wear is reached that adversely affects the measurement quality. In this paper, we describe the identification of tip abrasion in a system of SFM measurements. We attempt to model the tip-abrasion process as a concatenation of a mapping from the measured AFM data to a regression vector and a nonlinear mapping from the regressor space to the output space. The mapping is formed as a basis function expansion. Feedforward neural networks are used to approximate this mapping. The one-hidden layer network gave a good quality of fit for the training and test sets for the tip-abrasion system. We illustrate our method with AFM measurements of both fine periodic structures and randomly oriented sharp features and compare our neural network results with those obtained using other methods.

  6. OsB 2 and RuB 2, ultra-incompressible, hard materials: First-principles electronic structure calculations

    Science.gov (United States)

    Chiodo, S.; Gotsis, H. J.; Russo, N.; Sicilia, E.

    2006-07-01

    Recently it has been reported that osmium diboride has an unusually large bulk modulus combined with high hardness, and consequently is a most interesting candidate as an ultra-incompressible and hard material. The electronic and structural properties of the transition metal diborides OsB 2 and RuB 2 have been calculated within the local density approximation (LDA). It is shown that the high hardness is the result of covalent bonding between transition metal d states and boron p states in the orthorhombic structure.

  7. Dielectrophoretic positioning of single nanoparticles on atomic force microscope tips for tip-enhanced Raman spectroscopy.

    Science.gov (United States)

    Leiterer, Christian; Deckert-Gaudig, Tanja; Singh, Prabha; Wirth, Janina; Deckert, Volker; Fritzsche, Wolfgang

    2015-05-01

    Tip-enhanced Raman spectroscopy, a combination of Raman spectroscopy and scanning probe microscopy, is a powerful technique to detect the vibrational fingerprint of molecules at the nanometer scale. A metal nanoparticle at the apex of an atomic force microscope tip leads to a large enhancement of the electromagnetic field when illuminated with an appropriate wavelength, resulting in an increased Raman signal. A controlled positioning of individual nanoparticles at the tip would improve the reproducibility of the probes and is quite demanding due to usually serial and labor-intensive approaches. In contrast to commonly used submicron manipulation techniques, dielectrophoresis allows a parallel and scalable production, and provides a novel approach toward reproducible and at the same time affordable tip-enhanced Raman spectroscopy tips. We demonstrate the successful positioning of an individual plasmonic nanoparticle on a commercial atomic force microscope tip by dielectrophoresis followed by experimental proof of the Raman signal enhancing capabilities of such tips. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Plastic spatula with narrow long tip provides higher satisfactory smears for Pap test

    Directory of Open Access Journals (Sweden)

    Pervinder Kaur

    2013-01-01

    Full Text Available Background: Ayre spatula for cervical smear collection is being used despite the suggestion that different modified spatulas provide more satisfactory sampling. Aims: To see whether the cytological pickup improves with the use of long tipped spatula. Setting and Design: Rurally based University Hospital; crossover study. Materials and Methods: Pap smear using Ayre spatula in 500 and with plastic narrow long tip (Szalay spatula in 500 clinic attending women was taken and analyzed. Crossover smears were taken with modified spatula in 163 and using Ayre spatula in 187 women after 2 weeks of initial smears. The same pathologist made cytological reporting for all smears and was unaware of the type of spatula used. Results: Smears from Ayre spatula had significantly higher reports of inadequate smears (94 of 500 vs. 68 of 500 for Ayre and Szalay, respectively; P = 0.032 and it remained so even after crossover (94 of 187 vs. 70 of 163 for Ayre and Szalay, respectively; P = 0.2. Cellular quality appeared better with smears taken using Szalay spatula, but the overall abnormal smear detection rate remained similar with either collection tool (χ2 = 1.5; P = 0.2. Conclusions: Proportion of satisfactory smears is higher when long tip plastic spatula is used for collection of sample.

  9. Safety Tips: Basketball (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Safety Tips: Basketball KidsHealth / For Parents / Safety Tips: Basketball ... make sure they follow these tips. Why Basketball Safety Is Important Fortunately, very few basketball injuries are ...

  10. Application of RUB-01P beta radiometer to control contamination of milk and dairy produce

    International Nuclear Information System (INIS)

    Bachurin, A.V.; Donskaya, G.A.; Koroleva, M.S.; Titov, S.K.

    1990-01-01

    RUB-01P beta-radiometer to control radioactive contamination of milk and dairy produce characterized by a number of advantages as compared to RKB-4-1eM manufactured earlier is described. Device is designed using a new element base, simgle-action, characterized by increased reliability, can operate on-line with ELEKTRONIKA MK-64 programmed microcalculater. Radiometer output is printed out to a void operator errors and to record measurement results. Radiometer main error is maximum 50 %. Data on device sensitivity at measurements using BDZhB-05P, BDZhB-06P1, BDZhB-06P detection units are given

  11. Improved method for determining the stress relaxation at the crack tip

    Science.gov (United States)

    Grinevich, A. V.; Erasov, V. S.; Avtaev, V. V.

    2017-10-01

    A technique is suggested to determine the stress relaxation at the crack tip during tests of a specimen of a new type at a constant crack opening fixed by a stay bolt. The shape and geometry of the specimen make it possible to set the load and to determine the crack closure force after long-term exposure using the force transducer of a tensile-testing machine. The stress relaxation at the crack tip is determined in a V95pchT2 alloy specimen at elevated temperatures.

  12. Combined Scanning Nanoindentation and Tunneling Microscope Technique by Means of Semiconductive Diamond Berkovich Tip

    International Nuclear Information System (INIS)

    Lysenko, O; Novikov, N; Gontar, A; Grushko, V; Shcherbakov, A

    2007-01-01

    A combined Scanning Probe Microscope (SPM) - nanoindentation instrument enables submicron resolution indentation tests and in-situ scanning of structure surfaces. A newly developed technique is based on the scanning tunneling microscopy (STM) with integrated Berkovich diamond semiconductive tip. Diamond tips for a combined SPM were obtained using the developed procedure including the synthesis of the semiconductive borondoped diamond monocrystals by the temperature gradient method at high pressure - high temperature conditions and fabrication of the tips from these crystals considering their zonal structure. Separately grown semiconductive diamond single crystals were studied in order to find the best orientation of diamond crystals. Optimal scanning characteristics and experimental data errors were calculated by an analysis of the general functional dependence of the tunneling current from properties of the tip and specimen. Tests on the indentation and scanning of the gold film deposited on the silicon substrate employing the fabricated tips demonstrated their usability, acceptable resolution and sensitivity

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver). Portal hypertension can also occur in children, although children are much less likely to require a TIPS. ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  14. Survey of attitudes and practices of Irish nursing students towards hand hygiene, including handrubbing with alcohol-based hand rub.

    Science.gov (United States)

    Kingston, Liz M; O'Connell, Nuala H; Dunne, Colum P

    2017-05-01

    Hand hygiene is widely recognised as the most important measure a healthcare worker can take in preventing the spread of healthcare associated infections. As a member of the healthcare team, nursing students have direct patient contact during clinical practice; hence, good hand hygiene practice among nursing students is essential. Low to moderate levels of hand hygiene knowledge and poor attitudes and practices are reported among nursing students. However, less is known about their attitudes and practices of handrubbing with ABHR, even though handrubbing is the recommended optimum practice in most situations. The aim of this study was to explore attitudes and practices of hand hygiene, in particular handrubbing with alcohol-based hand rub, among nursing students in Ireland. This survey employed a descriptive, self-report design using a questionnaire to gather data. It was administered electronically to all undergraduate nursing students (n=342) in the Department of Nursing and Midwifery at the University of Limerick, Ireland in March and April 2015. Response rate was 66%. Attitudes towards hand hygiene were generally positive. Compliance with hand hygiene after contact with body fluid was high (99.5%) and before a clean or aseptic procedure (98.5%). However, suboptimal practices emerged, before touching a patient (85%), after touching a patient (87%) and after touching patients' surroundings (61%), with first year students more compliant than fourth year students. 16% of students were not aware of the clinical contraindications for using alcohol-based hand rub and 9% did not know when to use soap and water and when to use alcohol-based hand rub. Educators and practitioners play an important role in ensuring that nursing students develop appropriate attitudes towards hand hygiene and engage in optimal handrubbing practices. Raising awareness among nursing students of their responsibility in preventing the occurrence and reducing the transmission of HCAI as an on

  15. Tip off the HAT- Epigenetic control of learning and memory by Drosophila Tip60.

    Science.gov (United States)

    Xu, Songjun; Elefant, Felice

    2015-01-01

    Disruption of epigenetic gene control mechanisms involving histone acetylation in the brain causes cognitive impairment, a debilitating hallmark of most neurodegenerative disorders. Histone acetylation regulates cognitive gene expression via chromatin packaging control in neurons. Unfortunately, the histone acetyltransferases (HATs) that generate such neural epigenetic signatures and their mechanisms of action remain unclear. Our recent findings provide insight into this question by demonstrating that Tip60 HAT action is critical for morphology and function of the mushroom body (MB), the learning and memory center in the Drosophila brain. We show that Tip60 is robustly produced in MB Kenyon cells and extending axonal lobes and that targeted MB Tip60 HAT loss results in axonal outgrowth disruption. Functional consequences of loss and gain of Tip60 HAT levels in the MB are evidenced by defects in memory. Tip60 ChIP-Seq analysis reveals enrichment for genes that function in cognitive processes and accordingly, key genes representing these pathways are misregulated in the Tip60 HAT mutant fly brain. Remarkably, increasing levels of Tip60 in the MB rescues learning and memory deficits resulting from Alzheimer's disease associated amyloid precursor protein (APP) induced neurodegeneration. Our studies highlight the potential of HAT activators as a therapeutic option for cognitive disorders.

  16. Total Telephone Tips.

    Science.gov (United States)

    Corder, Lloyd E.; And Others

    This manual of telephone behavior tips for business and sales professionals offers ways to handle the disgruntled caller and makes suggestions on topics relevant to the telephone. The manual is divided into the following sections and subsections: (1) Common Courtesy (staff tips, answering the telephone, screening calls, transferring calls, taking…

  17. Efficacy of soap and water and alcohol-based hand-rub preparations against live H1N1 influenza virus on the hands of human volunteers.

    Science.gov (United States)

    Grayson, M Lindsay; Melvani, Sharmila; Druce, Julian; Barr, Ian G; Ballard, Susan A; Johnson, Paul D R; Mastorakos, Tasoula; Birch, Christopher

    2009-02-01

    Although pandemic and avian influenza are known to be transmitted via human hands, there are minimal data regarding the effectiveness of routine hand hygiene (HH) protocols against pandemic and avian influenza. Twenty vaccinated, antibody-positive health care workers had their hands contaminated with 1 mL of 10(7) tissue culture infectious dose (TCID)(50)/0.1 mL live human influenza A virus (H1N1; A/New Caledonia/20/99) before undertaking 1 of 5 HH protocols (no HH [control], soap and water hand washing [SW], or use of 1 of 3 alcohol-based hand rubs [61.5% ethanol gel, 70% ethanol plus 0.5% chlorhexidine solution, or 70% isopropanol plus 0.5% chlorhexidine solution]). H1N1 concentrations were assessed before and after each intervention by viral culture and real-time reverse-transcriptase polymerase chain reaction (PCR). The natural viability of H1N1 on hands for >60 min without HH was also assessed. There was an immediate reduction in culture-detectable and PCR-detectable H1N1 after brief cutaneous air drying--14 of 20 health care workers had H1N1 detected by means of culture (mean reduction, 10(3-4) TCID(50)/0.1 mL), whereas 6 of 20 had no viable H1N1 recovered; all 20 health care workers had similar changes in PCR test results. Marked antiviral efficacy was noted for all 4 HH protocols, on the basis of culture results (14 of 14 had no culturable H1N1; (P< .002) and PCR results (P< .001; cycle threshold value range, 33.3-39.4), with SW statistically superior (P< .001) to all 3 alcohol-based hand rubs, although the actual difference was only 1-100 virus copies/microL. There was minimal reduction in H1N1 after 60 min without HH. HH with SW or alcohol-based hand rub is highly effective in reducing influenza A virus on human hands, although SW is the most effective intervention. Appropriate HH may be an important public health initiative to reduce pandemic and avian influenza transmission.

  18. The Influence of Temperature on the Frictional Behavior of Duplex-Coated Die Steel Rubbing Against Forging Brass

    Science.gov (United States)

    Ebrahimzadeh, I.; Ashrafizadeh, F.

    2015-01-01

    Improvement of die life under hot forging of brass alloys is considered vital from both economical and technical points of view. One of the best methods for improving die life is duplex coatings. In this research, the influence of temperature on the tribological behavior of duplex-coated die steel rubbing against forging brass was investigated. The wear tests were performed on a pin-on-disk machine from room temperature to 700 °C; the pins were made in H13 hot work tool steel treated by plasma nitriding and by PVD coatings of TiN-TiAlN-CrAlN. The disks were machined from a two-phase brass alloy too. The results revealed that the friction coefficient of this tribosystem went through a maximum at 550 °C and decreased largely at 700 °C. Furthermore, the formation of Cr2O3 caused the reduction of friction coefficient at 700 °C. PVD coatings proved their wear resistance up to 550 °C, well above the working temperature of the brass forging dies.

  19. Biaxial loading and shallow-flaw effects on crack-tip constraint and fracture-toughness

    International Nuclear Information System (INIS)

    Pennell, W.E.; Bass, B.R.; Bryson, J.W.; McAfee, W.J.; Theiss, T.J.; Rao, M.C.

    1993-01-01

    Uniaxial tests of single-edged notched bend (SENB) specimens with both deep- and shallow-flaws have shown elevated fracture-toughness for the shallow flaws. The elevation in fracture-toughness for shallow flaws has been shown to be the result of reduced constraint at the crack-tip. Biaxial loading has the potential to increase constraint at the crack-tip and thereby reduce some of the shallow-flaw, fracture-toughness elevation. Biaxial fracture-toughness tests have shown that the shallow-flaw, fracture-toughness elevation is reduced but not eliminated by biaxial loading. Dual-parameter, fracture-toughness correlations have been proposed to reflect the effect of crack-tip constraint on fracture-toughness. Test results from the uniaxial and biaxial tests were analyzed using the dual-parameter technology. Discrepancies between analysis results and cleavage initiation site data from fractographic examinations indicate that the analysis models are in need of further refinement. Addition of a precleavage, ductile-tearing element to the analysis model has the potential to resolve the noted discrepancies

  20. CFD analysis of cloud cavitation on three tip-modified propellers with systematically varied tip geometry

    DEFF Research Database (Denmark)

    Shin, K. W.; Andersen, Poul

    2015-01-01

    The blade tip loading is often reduced as an effort to restrain sheet and tip vortex cavitation in the design of marine propellers. This CFD analysis demonstrates that an excessive reduction of the tip loading can cause cloud cavitation responsible for much of noise and surface erosion. Detached...

  1. Understanding and Mitigating Tip Leakage and Endwall Losses in High Pressure Ratio Cores

    Science.gov (United States)

    Christophel, Jesse

    2015-01-01

    Reducing endwall and tip secondary flow losses will be a key enabler for the next generation of commercial and military air transport and will be an improvement on the state-of-the-art in turbine loss reduction strategies. The objective of this research is three-fold: 1) To improve understanding of endwall secondary flow and tip clearance losses 2) To develop novel technologies to mitigate these losses and test them in low-speed cascade and rig environments 3) To validate predictive tools To accomplish these objectives, Pratt & Whitney (P&W) has teamed with Pennsylvania State University (PSU) to experimentally test new features designed by P&W. P&W will create new rim-cavity features to reduce secondary flow loss and improve purge flow cooling effectiveness and new blade tip features to manage leakage flows and reduce tip leakage secondary flow loss. P&W is currently developing technologies in these two areas that expect to be assimilated in the N+2/N+3 generation of commercial engines.

  2. A rubella serosurvey in postpartum women in the three regions of Peru Estudio serológico de rubéola en mujeres recién paridas en las tres regiones de Perú

    Directory of Open Access Journals (Sweden)

    Luis Suárez-Ognio

    2007-08-01

    Full Text Available OBJECTIVE: To determine the proportion of postpartum women aged 15-49 in Peru who are susceptible to rubella, in order to help address strategies to eliminate rubella and to prevent congenital rubella syndrome (CRS in the country. METHODS: A cross-sectional survey was conducted during March and April 2003 in six main regional hospitals, in the three geographic regions (coast, mountain, and jungle of Peru. For the postpartum women who provided written informed consent, a questionnaire was administered and a blood specimen was collected. Sera were tested for rubella immunoglobulin G (IgG antibody, using a commercial enzyme-linked immunosorbent serologic assay (ELISA kit. Univariate, bivariate, and multivariate analyses were carried out to assess risk factors for susceptibility. RESULTS: In total, 1 236 postpartum women were enrolled. The overall proportion of IgG-antibody negative women was 12.8% (95% confidence interval (CI: 10.9%-14.6%. Bivariate analysis found the following variables associated with susceptibility: living in the jungle region (odds ratio (OR = 1.65; 95% CI: 1.13-2.42; age OBJETIVO: Determinar la proporción de mujeres recién paridas de 15-49 años de edad susceptibles a la rubéola en Perú, a fin de contribuir a establecer estrategias para eliminar la rubéola y evitar el síndrome de rubéola congénita (SRC en el país. MÉTODOS: Se realizó un estudio transversal en marzo y abril de 2003 en seis hospitales regionales principales de tres regiones geográficas (costa, sierra y selva de Perú. A las mujeres recién paridas que dieron su consentimiento informado por escrito se les aplicó un cuestionario y se les tomó una muestra de sangre. La detección serológica de anticuerpos de la clase IgG contra rubéola se realizó mediante un ensayo inmunoenzimático comercial tipo ELISA. Se realizaron análisis con una, dos y múltiples variables para evaluar los factores de riesgo de ser susceptible a la enfermedad. RESULTADOS: En

  3. Chemically etched fiber tips for near-field optical microscopy: a process for smoother tips.

    Science.gov (United States)

    Lambelet, P; Sayah, A; Pfeffer, M; Philipona, C; Marquis-Weible, F

    1998-11-01

    An improved method for producing fiber tips for scanning near-field optical microscopy is presented. The improvement consists of chemically etching quartz optical fibers through their acrylate jacket. This new method is compared with the previous one in which bare fibers were etched. With the new process the meniscus formed by the acid along the fiber does not move during etching, leading to a much smoother surface of the tip cone. Subsequent metallization is thus improved, resulting in better coverage of the tip with an aluminum opaque layer. Our results show that leakage can be avoided along the cone, and light transmission through the tip is spatially limited to an optical aperture of a 100-nm dimension.

  4. ADHD: Tips to Try

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español ADHD: Tips to Try KidsHealth / For Teens / ADHD: Tips to Try Print en español TDAH: Consejos que puedes probar ADHD , short for attention deficit hyperactivity disorder , is a ...

  5. Magnet pole tips

    Science.gov (United States)

    Thorn, Craig E.; Chasman, Chellis; Baltz, Anthony J.

    1984-04-24

    An improved magnet which more easily provides a radially increasing magnetic field, as well as reduced fringe field and requires less power for a given field intensity. The subject invention comprises a pair of spaced, opposed magnetic poles which further comprise a pair of pole roots, each having a pole tip attached to its center. The pole tips define the gap between the magnetic poles and at least a portion of each pole tip is separated from its associated pole root. The separation begins at a predetermined distance from the center of the pole root and increases with increasing radial distance while being constant with azimuth within that portion. Magnets in accordance with the subject invention have been found to be particularly advantageous for use in large isochronous cyclotrons.

  6. Cradle Cap: Treatment

    Science.gov (United States)

    Cradle cap Treatment Cradle cap usually doesn't require medical treatment. It clears up on its own within a few months. In the meantime, wash ... tips can help you control and manage cradle cap. Gently rub your baby's scalp with your fingers ...

  7. Effects of the Tongue-in-Groove Maneuver on Nasal Tip Rotation.

    Science.gov (United States)

    Antunes, Marcelo B; Quatela, Vito C

    2018-03-27

    Changes in nasal tip rotation is a very common maneuver performed during rhinoplasty. Among the many techniques used to achieve this goal is the tongue-in-groove (TIG). This study addresses the long-term effect of the TIG on the nasal tip rotation 1 year after rhinoplasty. The authors prospectively identified patients who were submitted to a rhinoplasty with a TIG maneuver over a period of 1 year. The angle of rotation was measured along the nostril axis angle. The data was analyzed using the t-test and a linear regression model. Seventeen patients were included. The average preoperative tip rotation was 93.95° (SD, 3.12°). Immediate postoperative tip rotation averaged 114.47° (SD, 3.79°). At the 1-year follow-up appointment, the tip rotation averaged 106.55° (SD, 3.54°). There was a significant loss of rotation at the 1-year postoperative visit (pTIG is a more dependable technique than the ones that rely on healing and contraction to obtain rotation. Our data demonstrated a significant loss of rotation during the first year. This suggests that the surgeon needs to slightly overcorrect the tip rotation to account for this loss.

  8. Numerical investigation of three wind turbine blade tips

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, J.; Soerensen, N.N.

    2002-08-01

    The complex three-dimensional flow around three different tip shapes on a rotating wind turbine blade is investigated and analyzed using Computational Fluid Dynamics. Differences in production, flap wise bending moments and forces are discussed. A method for determining the local inflow angle of attack is presented and further analysis is performed on lift and drag coefficients. It is shown that the original Standard tip results in a more concentrated tip vortex leading to a steeper gradient on both tangential and normal forces when approaching the tip, whereas the two tapered tips show a more flat behavior. This again leads to lower flap wise bending moments and lower production for the Standard tip compared to the two tapered tips. At 12 m/s, though, the Swept tip shows a separation pattern on the surface. This separation causes a decrease in normal force and an increase in tangential force. The Taper tip keeps the higher loading causing the flap wise bending moment to be higher as seen in measurements. To determine the radial variation of lift and drag coefficients the local inflow angle of attack is determined. It is shown that the Standard tip experiences a slightly larger angle of attack at the tip compared to the two tapered tips. The lift coefficients are kept at a more constant level for the two tapered tips due to the decrease in chord, while the drag coefficients actually decrease for the two tapered tips, especially for the Swept tip. For the Swept tip at 12 m/s both lift and drag coefficients changed considerably due to the separation. Differences in aerodynamic damping of the three tips were investigated using HAWCDAMP. The Standard tip seems to be slightly less damped with respect to the edgewise vibrations. (au)

  9. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve.

    Directory of Open Access Journals (Sweden)

    Aeri Yoo

    Full Text Available To compare a modified phacoemulsification tip with the established micro tip, in terms of temperature at the corneal wound, efficiency, and chatter events, using the Centurion® Vision system.Eighty porcine eyes were randomized into 4 groups: 1sleeveless conventional 45D MiniFlared ABS® Kelman tip (1.1-mm incision; 2sleeveless new modified 45D ABS® INTREPID® balanced tip(1.1-mm incision; 3 Kelman tip with own sleeve (2.2-mm incision; 4Balanced tip with modified 4-rib sleeve (2.2-mm incision. Measurements were taken with 2 settings: longitudinal(power 40% and 70% and torsional mode (power 40% and 100%. Peak temperatures were measured 0, 10, 30, and 60 seconds after continuous ultrasound power. For the efficiency test, porcine lens nuclei were formalin soaked and cut into 2.0 mm3 cubes. Efficiency and chatter were examined.In all longitudinal settings, the sleeveless groups(1 and 2 showed lower temperatures than the sleeved groups(3 and 4 (P = 0.003. In 100% torsional mode, groups 3 and 4 produced significantly different temperatures(37.13 ± 1.44 and 35.14 ± 0.54, respectively; P = 0.007.The efficiency, in a 100% power torsional setting, was13.52 ± 2.60 sec for group 4, and 44.45± 14.75 sec for group 3 (P<0.001.The two different bare tips show no significant differences in thermogenesis. However, the balanced tip with sleeve produces lower temperaturesat100% torsional power and better efficiency than the Kelman tip.

  10. On short cracks that depart from elastoplastic notch tips

    Directory of Open Access Journals (Sweden)

    Verônica Miquelin Machado

    2017-07-01

    Full Text Available The behavior of short cracks that depart from elastoplastic notch tips is modeled to estimate the stresses required to initiate and to propagate cracks in notched structural components, and to evaluate the size of tolerable crack-like defects under general loading conditions. This analysis can model both fatigue and environmentally assisted cracking problems; can evaluate notch sensitivity in both cases; and can as well be used to establish design or acceptance criteria for tolerable non-propagating crack-like defects in such cases. The growth of short cracks is assumed driven by the applied stresses and by the stress gradient ahead the notch tip, and supported by the material resistances to crack initiation and to long crack propagation by fatigue or EAC. In the elastoplastic case, the stress gradient ahead of the notch tip is quantified by a J-field to consider the short crack behavior. The tolerable short crack predictions made by this model are evaluated by suitable fatigue and EAC tests of notched specimens specially designed to start nonpropagating cracks from the notch tips, both under elastic and elastoplastic conditions.

  11. Lightning Safety Tips and Resources

    Science.gov (United States)

    ... Services Careers Contact Us Glossary Safety National Program Lightning Safety Tips and Resources Weather.gov > Safety > Lightning Safety Tips and Resources Lightning Resources Lightning strikes ...

  12. Numerical Analysis of the Influence of Tip Devices on the Power Coefficient of a VAWT

    OpenAIRE

    Federico Amato; Gabriele Bedon; Marco Raciti Castelli; Ernesto Benini

    2013-01-01

    The aerodynamic performances of vertical axis wind turbines are highly affected by tip vortexes. In the present work, different tip devices are considered and simulated against a baseline rotor configuration, with the aim of identifying the best tip architecture. Three different configurations are tested: winglets, an elliptic termination and an aerodynamic bulkhead. A comparative analysis on the most promising architectures is conducted, focusing also on blade torque evo...

  13. Tip Cells in Angiogenesis

    NARCIS (Netherlands)

    M.G. Dallinga (Marchien); S.E.M. Boas (Sonja); I. Klaassen (Ingeborg); R.M.H. Merks (Roeland); C.J.F. van Noorden; R.O. Schlingemann (Reinier)

    2015-01-01

    htmlabstractIn angiogenesis, the process in which blood vessel sprouts grow out from a pre-existing vascular network, the so-called endothelial tip cells play an essential role. Tip cells are the leading cells of the sprouts; they guide following endothelial cells and sense their environment for

  14. Tip model of cold fission

    International Nuclear Information System (INIS)

    Goennenwein, F.; Boersig, B.

    1991-01-01

    Cold fission is defined to be the limiting case of nuclear fission where virtually all of the available energy is converted into the total kinetic energy of the fragments. The fragments have, therefore, to be born in or at least close to their respective ground states. Starting from the viewpoint that cold fission corresponds to most compact scission configurations, energy constraints have been exploited to calculate minimum tip distances between the two nascent fragments in binary fission. Crucial input parameters to this tip model of cold fission are the ground-state deformations of fragment nuclei. It is shown that the minimum tip distances being compatible with energy conservation vary strongly with both the mass and charge fragmentation of the fission prone nucleus. The tip distances refer to nuclei with equivalent sharp surfaces. In keeping with the size of the surface width of leptodermous nuclei, only configurations where the tip distances are smaller than a few fm may be considered as valid scission configurations. From a comparison with experimental data on cold fission this critical tip distance appears to be 3.0 fm for the model parameters chosen. Whenever the model calculation yields tip distances being smaller than the critical value, a necessary condition for attaining cold fission is considered to be fulfilled. It is shown that this criterion allows to understand in fair agreement with experiment which mass fragmentations are susceptible to lead to cold fission and which fragment-charge divisions are the most favored in each isobaric mass chain. Being based merely on energy arguments, the model cannot aim at predicting fragment yields in cold fission. However, the tip model proposed appears well suited to delineate the phase space where cold fission phenomena may come into sight. (orig.)

  15. MELD Score as a Predictor of Early Death in Patients Undergoing Elective Transjugular Intrahepatic Portosystemic Shunt (TIPS) Procedures

    International Nuclear Information System (INIS)

    Montgomery, Aaron; Ferral, Hector; Vasan, Rajiv; Postoak, Darren W.

    2005-01-01

    Purpose. To Evaluate the MELD score as a predictor of 30-day mortality in patients undergoing elective TIPS procedures. Methods. This was a retrospective, IRB-approved study. The medical records of all patients who underwent a TIPS procedure between May 1, 1999 and June 1, 2003 in a single institution were reviewed. Patients who underwent elective TIPS were selected. Elective TIPS was performed in 119 patients with a mean age of 55.1 (± 9.6) years. The MELD and Child-Pugh scores before TIPS, etiology of cirrhosis, portosystemic gradients before and after TIPS, procedure time, and procedural complications were obtained from the medical records. The MELD and Child-Pugh scores before TIPS were compared between the survivor group (SG) and the early death (EDG) group. The early death rate was calculated for MELD score subgroups (1-10, 11-17, 18-24, and >24). Data were analyzed using the Fisher exact test, chi-square test and independent-sample t-test. A p value of less than 0.05 was considered significant. Results. Technical success rate was 100%. The early death rate was 10.9% (13/119). The mean MELD scores before TIPS were 19.4 (± 5.9) (EDG) and 14 (± 4.2) (SG) (p = 0.025). The early death rate was highest in the pre-TIPS MELD > 24 subgroup. The Child-Pugh scores were 9.0 (± 1.6) (SG) and 9.8 ± 1.06 (EDG) (p 0.08). The mean portosystemic gradients before TIPS were 20.5 (± 7.7) mmHg (EDG) and 22.7 (± 7.3) (SG) (p > 1) and the mean portosystemic gradients after TIPS were 6.5 (± 3.5) (EDG) and 6.9 (± 2.4) (SG) (p > 1). The mean procedural times were 95.6 (± 8.4) min (EDG) and 89.2 (± 7.5) min (SG) (p > 1). No early death was attributed to a fatal complication during TIPS. Conclusion. The MELD score is useful in identifying patients at a higher risk of early death after an elective TIPS. On the basis of our results, we do not endorse elective TIPS in patients with MELD scores > 24

  16. Tip Vortex and Wake Characteristics of a Counterrotating Open Rotor

    Science.gov (United States)

    VanZante, Dale E.; Wernet, Mark P.

    2012-01-01

    One of the primary noise sources for Open Rotor systems is the interaction of the forward rotor tip vortex and blade wake with the aft rotor. NASA has collaborated with General Electric on the testing of a new generation of low noise, counterrotating Open Rotor systems. Three-dimensional particle image velocimetry measurements were acquired in the intra-rotor gap of the Historical Baseline blade set. The velocity measurements are of sufficient resolution to characterize the tip vortex size and trajectory as well as the rotor wake decay and turbulence character. The tip clearance vortex trajectory is compared to results from previously developed models. Forward rotor wake velocity profiles are shown. Results are presented in a form as to assist numerical modeling of Open Rotor system aerodynamics and acoustics.

  17. Early warning of climate tipping points

    Science.gov (United States)

    Lenton, Timothy M.

    2011-07-01

    A climate 'tipping point' occurs when a small change in forcing triggers a strongly nonlinear response in the internal dynamics of part of the climate system, qualitatively changing its future state. Human-induced climate change could push several large-scale 'tipping elements' past a tipping point. Candidates include irreversible melt of the Greenland ice sheet, dieback of the Amazon rainforest and shift of the West African monsoon. Recent assessments give an increased probability of future tipping events, and the corresponding impacts are estimated to be large, making them significant risks. Recent work shows that early warning of an approaching climate tipping point is possible in principle, and could have considerable value in reducing the risk that they pose.

  18. AFM tip-sample convolution effects for cylinder protrusions

    Science.gov (United States)

    Shen, Jian; Zhang, Dan; Zhang, Fei-Hu; Gan, Yang

    2017-11-01

    A thorough understanding about the AFM tip geometry dependent artifacts and tip-sample convolution effect is essential for reliable AFM topographic characterization and dimensional metrology. Using rigid sapphire cylinder protrusions (diameter: 2.25 μm, height: 575 nm) as the model system, a systematic and quantitative study about the imaging artifacts of four types of tips-two different pyramidal tips, one tetrahedral tip and one super sharp whisker tip-is carried out through comparing tip geometry dependent variations in AFM topography of cylinders and constructing the rigid tip-cylinder convolution models. We found that the imaging artifacts and the tip-sample convolution effect are critically related to the actual inclination of the working cantilever, the tip geometry, and the obstructive contacts between the working tip's planes/edges and the cylinder. Artifact-free images can only be obtained provided that all planes and edges of the working tip are steeper than the cylinder sidewalls. The findings reported here will contribute to reliable AFM characterization of surface features of micron or hundreds of nanometers in height that are frequently met in semiconductor, biology and materials fields.

  19. MEMS Reliability: Infrastructure, Test Structures, Experiments, and Failure Modes

    Energy Technology Data Exchange (ETDEWEB)

    TANNER,DANELLE M.; SMITH,NORMAN F.; IRWIN,LLOYD W.; EATON,WILLIAM P.; HELGESEN,KAREN SUE; CLEMENT,J. JOSEPH; MILLER,WILLIAM M.; MILLER,SAMUEL L.; DUGGER,MICHAEL T.; WALRAVEN,JEREMY A.; PETERSON,KENNETH A.

    2000-01-01

    The burgeoning new technology of Micro-Electro-Mechanical Systems (MEMS) shows great promise in the weapons arena. We can now conceive of micro-gyros, micro-surety systems, and micro-navigators that are extremely small and inexpensive. Do we want to use this new technology in critical applications such as nuclear weapons? This question drove us to understand the reliability and failure mechanisms of silicon surface-micromachined MEMS. Development of a testing infrastructure was a crucial step to perform reliability experiments on MEMS devices and will be reported here. In addition, reliability test structures have been designed and characterized. Many experiments were performed to investigate failure modes and specifically those in different environments (humidity, temperature, shock, vibration, and storage). A predictive reliability model for wear of rubbing surfaces in microengines was developed. The root causes of failure for operating and non-operating MEMS are discussed. The major failure mechanism for operating MEMS was wear of the polysilicon rubbing surfaces. Reliability design rules for future MEMS devices are established.

  20. Reconstruction of the Tip-Surface Interaction Potential by Analysis of the Brownian Motion of an Atomic Force Microscope Tip

    NARCIS (Netherlands)

    Willemsen, O.H.; Kuipers, L.; van der Werf, Kees; de Grooth, B.G.; Greve, Jan

    2000-01-01

    The thermal movement of an atomic force microscope (AFM) tip is used to reconstruct the tip-surface interaction potential. If a tip is brought into the vicinity of a surface, its movement is governed by the sum of the harmonic cantilever potential and the tip-surface interaction potential. By

  1. Tips for Living with Scleroderma

    Science.gov (United States)

    ... Patients Tips for Living Tips for Living with Scleroderma Ways to help manage your symptoms The Scleroderma ... help find improved therapies and a cure for scleroderma! Your gift today will be matched to have ...

  2. Modeling tectonic heat flow and source rock maturity in the Rub' Al-Khali Basin (Saudi Arabia), with the help of GOCE satellite gravity data

    NARCIS (Netherlands)

    Abdul Fattah, R.; Meekes, S.; Bouman, J.; Ebbing, J.; Haagmans, R.

    2014-01-01

    A 3D basin modeling study was carried out to reconstruct the regional heat flow and source rock maturity in the Rub'al-Khali basin. Gravity gradient data from the GOCE satellite were used to model deep structures, such as the Moho interface. Tectonic heat flow was modeled using the GOCE-based Moho

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... or bypass, without the risks that accompany open surgery. TIPS is a minimally invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  4. Measurement accuracy of weighing and tipping-bucket rainfall intensity gauges under dynamic laboratory testing

    Science.gov (United States)

    Colli, M.; Lanza, L. G.; La Barbera, P.; Chan, P. W.

    2014-07-01

    The contribution of any single uncertainty factor in the resulting performance of infield rain gauge measurements still has to be comprehensively assessed due to the high number of real world error sources involved, such as the intrinsic variability of rainfall intensity (RI), wind effects, wetting losses, the ambient temperature, etc. In recent years the World Meteorological Organization (WMO) addressed these issues by fostering dedicated investigations, which revealed further difficulties in assessing the actual reference rainfall intensity in the field. This work reports on an extensive assessment of the OTT Pluvio2 weighing gauge accuracy when measuring rainfall intensity under laboratory dynamic conditions (time varying reference flow rates). The results obtained from the weighing rain gauge (WG) were also compared with a MTX tipping-bucket rain gauge (TBR) under the same test conditions. Tests were carried out by simulating various artificial precipitation events, with unsteady rainfall intensity, using a suitable dynamic rainfall generator. Real world rainfall data measured by an Ogawa catching-type drop counter at a field test site located within the Hong Kong International Airport (HKIA) were used as a reference for the artificial rain generation system. Results demonstrate that the differences observed between the laboratory and field performance of catching-type gauges are only partially attributable to the weather and operational conditions in the field. The dynamics of real world precipitation events is responsible for a large part of the measurement errors, which can be accurately assessed in the laboratory under controlled environmental conditions. This allows for new testing methodologies and the development of instruments with enhanced performance in the field.

  5. Structure and dynamics of TIP3P, TIP4P, and TIP5P water near smooth and atomistic walls of different hydroaffinity

    International Nuclear Information System (INIS)

    Harrach, Michael F.; Drossel, Barbara

    2014-01-01

    We perform molecular dynamics simulations to observe the structure and dynamics of water using different water models (TIP3P, TIP4P, TIP5P) at ambient conditions, constrained by planar walls, which are either modeled by smooth potentials or regular atomic lattices, imitating the honeycomb-structure of graphene. We implement walls of different hydroaffinity, different lattice constant, and different types of interaction with the water molecules. We find that in the hydrophobic regime the smooth wall generally represents a good abstraction of the atomically rough walls, while in the hydrophilic regime there are noticeable differences in structure and dynamics between all stages of wall roughness. For a small lattice constant however the smooth and the atomically rough wall still share a number of structural and dynamical similarities. Out of the three water models, TIP5P water shows the largest degree of tetrahedral ordering and is often the one that is least perturbed by the presence of the wall

  6. Preoperative Hand Decontamination in Ophthalmic Surgery: A Comparison of the Removal of Bacteria from Surgeons' Hands by Routine Antimicrobial Scrub versus an Alcoholic Hand Rub.

    Science.gov (United States)

    Forer, Yaara; Block, Colin; Frenkel, Shahar

    2017-09-01

    The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a preoperative hand disinfection method.

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... then placed in this tunnel to keep the pathway open. Patients who typically need a TIPS have ... and stomach. A TIPS procedure involves creating a pathway through the liver that connects the portal vein ( ...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and/or hydrothorax (in the chest). Budd-Chiari syndrome , a blockage in one or more veins that ... intentionally to solve the problem. Although extremely rare, children may also require a TIPS procedure. TIPS in ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the esophagus and stomach. A TIPS procedure involves creating a pathway through the liver that connects the ... diseases. This can result in significant challenges in creating the TIPS. top of page Additional Information and ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... TIPS. top of page What are some common uses of the procedure? A TIPS is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... recovery time than surgery. Your TIPS should have less of an effect than open surgical bypass on ...

  13. Light depolarization induced by metallic tips in apertureless near-field optical microscopy and tip-enhanced Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gucciardi, P G [CNR-Istituto per i Processi Chimico-Fisici, sezione Messina, Salita Sperone, Contrada Papardo, I-98158 Faro Superiore, Messina (Italy); Lopes, M; Deturche, R; Julien, C; Barchiesi, D; Chapelle, M Lamy de la [Institut Charles Delaunay-CNRS FRE 2848, Laboratoire de Nanotechnologie et d' Instrumentation Optique, Universite de Technologie de Troyes, 12 rue Marie Curie, BP2060, 10010 Troyes (France)

    2008-05-28

    We have investigated the depolarization effects of light scattered by sharp tips used for apertureless near-field optical microscopy. Dielectric and metal coated tips have been investigated and depolarization factors between 5 and 30% have been measured, changing as a function of the incident light polarization and of the tip shape. The experimental results are in good agreement with theoretical calculations performed by the finite element method, giving a near-field depolarization factor close to 10%. The effect of depolarization has been investigated in polarized tip-enhanced Raman spectroscopy (TERS) experiments; the depolarization gives rise to forbidden Raman modes in Si crystals.

  14. Accurate measurement of Atomic Force Microscope cantilever deflection excluding tip-surface contact with application to force calibration

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Ashley D.; Blanch, Adam J.; Quinton, Jamie S.; Gibson, Christopher T., E-mail: christopher.gibson@flinders.edu.au

    2013-08-15

    Considerable attention has been given to the calibration of AFM cantilever spring constants in the last 20 years. Techniques that do not require tip-sample contact are considered advantageous since the imaging tip is not at risk of being damaged. Far less attention has been directed toward measuring the cantilever deflection or sensitivity, despite the fact that the primary means of determining this factor relies on the AFM tip being pressed against a hard surface, such as silicon or sapphire; which has the potential to significantly damage the tip. A recent method developed by Tourek et al. in 2010 involves deflecting the AFM cantilever a known distance from the imaging tip by pressing the cantilever against a sharpened tungsten wire. In this work a similar yet more precise method is described, whereby the deflection of the cantilever is achieved using an AFM probe with a spring constant much larger than the test cantilever, essentially a rigid cantilever. The exact position of loading on the test cantilever was determined by reverse AFM imaging small spatial markers that are milled into the test cantilever using a focussed ion beam. For V shaped cantilevers it is possible to reverse image the arm intersection in order to determine the exact loading point without necessarily requiring FIB milled spatial markers, albeit at the potential cost of additional uncertainty. The technique is applied to tip-less, beam shaped and V shaped cantilevers and compared to the hard surface contact technique with very good agreement (on average less than 5% difference). While the agreement with the hard surface contact technique was very good the error on the technique is dependent upon the assumptions inherent in the method, such as cantilever shape, loading point distance and ratio of test to rigid cantilever spring constants. The average error ranged between 2 to 5% for the majority of test cantilevers studied. The sensitivity derived with this technique can then be used to

  15. Comparative assessment of local tolerance of alcohols commonly used in alcohol-based hand rubs for hand hygiene.

    Science.gov (United States)

    Manche, Monique; Foligné, Benoît; Sauty, Mathieu; Platel, Anne; Vercauteren, Eric; Rauwel, Gaétan; Catoire, Sophie; Ficheux, Hervé; Criquelion, Jacques; Nesslany, Fabrice

    2017-10-01

    Hand hygiene plays a key role in nosocomial infection prevention. To achieve users' adherence, products' dermal tolerance is essential. We aimed at making a comparative assessment of skin irritation and phototoxicity of the 3 alcohols commonly used in alcohol-based hand rubs (Ethanol, Propan-2-ol, Propan-1-ol) at 60, 70, 80 or 85% w/w in water or with co-formulates (hydrating, emollient and skin protective agents). In vitro validated OECD methods 439 and 432 were used. For irritation, EpiSkin™ Small Model was the chosen Reconstructed Human Epidermis (RhE). For phototoxicity, co-formulates alone or in mixture with and without alcohol were tested using BALB/c 3T3 cell cultures. Whilst Ethanol and Propan-2-ol could not be differentiated and displayed good skin tolerance profiles, Propan-1-ol based products lead to significant viability impairments of RhE at 60, 70 or 80% and at 60% in the presence of co-formulates. However, these results could not be reproduced in another RhE model. Taking also into account bibliographic data on Propan-1-ol, this suggests that our results are probably related to a lack of specificity of the used RhE. Therefore, it can be relevant in case of significant results to use two different RhE models before performing any classification and/or performing any complementary tests. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. The Mystical Process in Del templo de su cuerpo, Book of Poems by Rubén Bonifaz Nuño

    Directory of Open Access Journals (Sweden)

    Jocelyn Martínez Elizalde

    2015-02-01

    Full Text Available This work proposes an interpretation of the strophic structure of Del templo de su cuerpo (1992, book of poems by Rubén Bonifaz Nuño (Veracruz, México,1923, according to its symbolic relation with the Kabbalah. Kabbalah is “amethod of religious contemplation, a theosophical system based on the sefirot or emanations of divinity which uses certain techniques to interpret the letters of the Hebrew alphabet in order to reach the mystical elevation”. However, inDel templo de su cuerpo, the reader will find that Kabbalah is also a processthat leads to knowledge and seeks the “mystical elevation”, with the differencethat what is sublimated is not the soul, but the body. Del templo de su cuerpois a complex system of poetic symbols that presents an example of mystical erotic poetry. This book contains symbols that represent the sacred act: theperfect circle, the embrace of the lovers, and the androgyne. Also, each of thesefirot has an elaborate connection with other symbols: parts of the body, colors,days of the week, planets, natural elements, Star Signs… everything works in a perfect balance, held by the female body. The poetry of Rubén BonifazNuño is a quest for the salvation of the body through love and words, a brief attempt to remain.

  17. Brine saturation technique for extraction of light filth from rubbed, ground, and whole sage: collaborative study.

    Science.gov (United States)

    Freeman, C C

    1985-01-01

    A new approach to the isolation of light filth from the 3 commercial forms of sage was studied collaboratively. It incorporates a simple isopropanol defatting, followed by saturation of the product with brine by alternately heating and cooling, and subsequent trapping of filth from tap water with olive oil. This method circumvents the use of hazardous, expensive solvents and more time-consuming pretreatment procedures. Overall recoveries were 92.1% for rodent hair and 78.7% for insect fragments on clean, easy-to-read papers. An additional blending step was necessary to obtain satisfactory recovery of rodent hair fragments from whole sage. The method has been adopted official first action for light filth in rubbed and ground sage only.

  18. Superconducting phase transition in STM tips

    Energy Technology Data Exchange (ETDEWEB)

    Eltschka, Matthias; Jaeck, Berthold; Assig, Maximilian; Etzkorn, Markus; Ast, Christian R. [Max Planck Institute for Solid State Research, Stuttgart (Germany); Kern, Klaus [Max Planck Institute for Solid State Research, Stuttgart (Germany); Ecole Polytechnique Federale de Lausanne (Switzerland)

    2015-07-01

    The superconducting properties of systems with dimensions comparable to the London penetration depth considerably differ from macroscopic systems. We have studied the superconducting phase transition of vanadium STM tips in external magnetic fields. Employing Maki's theory we extract the superconducting parameters such as the gap or the Zeeman splitting from differential conductance spectra. While the Zeeman splitting follows the theoretical description of a system with s=1/2 and g=2, the superconducting gaps as well as the critical fields depend on the specific tip. For a better understanding of the experimental results, we solve a one dimensional Usadel equation modeling the superconducting tip as a cone with the opening angle α in an external magnetic field. We find that only a small region at the apex of the tip is superconducting in high magnetic fields and that the order of the phase transition is directly determined by α. Further, the spectral broadening increases with α indicating an intrinsic broadening mechanism due to the conical shape of the tip. Comparing these calculations to our experimental results reveals the order of the superconducting phase transition of the STM tips.

  19. Coating of tips for electrochemical scanning tunneling microscopy by means of silicon, magnesium, and tungsten oxides

    Science.gov (United States)

    Salerno, Marco

    2010-09-01

    Different combinations of metal tips and oxide coatings have been tested for possible operation in electrochemical scanning tunneling microscopy. Silicon and magnesium oxides have been thermally evaporated onto gold and platinum-iridium tips, respectively. Two different thickness values have been explored for both materials, namely, 40 and 120 nm for silicon oxide and 20 and 60 nm for magnesium oxide. Alternatively, tungsten oxide has been grown on tungsten tips via electrochemical anodization. In the latter case, to seek optimal results we have varied the pH of the anodizing electrolyte between one and four. The oxide coated tips have been first inspected by means of scanning electron microscopy equipped with microanalysis to determine the morphological results of the coating. Second, the coated tips have been electrically characterized ex situ for stability in time by means of cyclic voltammetry in 1 M aqueous KCl supporting electrolyte, both bare and supplemented with K3[Fe(CN)6] complex at 10 mM concentration in milliQ water as an analyte. Only the tungsten oxide coated tungsten tips have shown stable electrical behavior in the electrolyte. For these tips, the uncoated metal area has been estimated from the electrical current levels, and they have been successfully tested by imaging a gold grating in situ, which provided stable results for several hours. The successful tungsten oxide coating obtained at pH=4 has been assigned to the WO3 form.

  20. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  1. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  2. Tips for Good Electronic Presentations.

    Science.gov (United States)

    Strasser, Dennis

    1996-01-01

    Describes library uses of presentation graphics software and offers tips for creating electronic presentations. Tips include: audience retention; visual aid options; software package options; presentation planning; presentation showing; and use of text, colors, and graphics. Sidebars note common presentation errors and popular presentation…

  3. Fiber optic muzzle brake tip for reducing fiber burnback and stone retropulsion during thulium fiber laser lithotripsy

    Science.gov (United States)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-01-01

    The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A "fiber muzzle brake" was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-outer-diameter, 360-μm-inner-diameter tube with a 275-μm-diameter through hole located 250 μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40±4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25±4 s (n=10) without visible distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers, respectively. The muzzle brake fiber tip simultaneously provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  4. Comparison of different types of phacoemulsification tips. I. Quantitative analysis of elemental composition and tip surface microroughness.

    Science.gov (United States)

    Tsaousis, Konstantinos T; Werner, Liliana; Perez, Jesus Paulo; Li, He J; Reiter, Nicholas; Guan, Jia J; Mamalis, Nick

    2016-09-01

    To evaluate the elemental composition of phacoemulsification tips and their surface roughness in the microscale. John A. Moran Eye Center and Utah Nanofab, College of Engineering, University of Utah, Salt Lake City, Utah, USA. Experimental study. Seven types of phacoemulsification tips were studied. The phaco tips were examined through energy-dispersive x-ray spectroscopy (EDS) and x-ray photoelectron spectroscopy (XPS) for elemental composition. In addition, the roughness of the opening in all tips was assessed through 3-dimensional white-light interferometry. Elemental analysis showed considerable differences in the surface layers between manufacturers. Alcon tips had a thinner oxidized titanium (Ti) layer in their surface. Through XPS, vanadium was not detected in the superficial layers of any tip, but only in deeper levels. The microroughness surface analysis showed comparable results regarding their root-mean-square (RMS) metric. Maximum peak valley distance values varied and appeared to be dependent on the quality of material process rather than the material itself. Phacoemulsification tips are made of Ti alloys and showed differences between models, especially regarding their composition in the superficial layers. Their opening end roughness showed an overall appropriate RMS value of less than 1.0 μm in all cases. The existence of small defected areas highlights the importance of adequate quality control of these critical surgical instruments. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Sound source location in cavitating tip vortices

    International Nuclear Information System (INIS)

    Higuchi, H.; Taghavi, R.; Arndt, R.E.A.

    1985-01-01

    Utilizing an array of three hydrophones, individual cavitation bursts in a tip vortex could be located. Theoretically, four hydrophones are necessary. Hence the data from three hydrophones are supplemented with photographic observation of the cavitating tip vortex. The cavitation sound sources are found to be localized to within one base chord length from the hydrofoil tip. This appears to correspond to the region of initial tip vortex roll-up. A more extensive study with a four sensor array is now in progress

  6. Detection of Membrane Puncture with Haptic Feedback using a Tip-Force Sensing Needle.

    Science.gov (United States)

    Elayaperumal, Santhi; Bae, Jung Hwa; Daniel, Bruce L; Cutkosky, Mark R

    2014-09-01

    This paper presents calibration and user test results of a 3-D tip-force sensing needle with haptic feedback. The needle is a modified MRI-compatible biopsy needle with embedded fiber Bragg grating (FBG) sensors for strain detection. After calibration, the needle is interrogated at 2 kHz, and dynamic forces are displayed remotely with a voice coil actuator. The needle is tested in a single-axis master/slave system, with the voice coil haptic display at the master, and the needle at the slave end. Tissue phantoms with embedded membranes were used to determine the ability of the tip-force sensors to provide real-time haptic feedback as compared to external sensors at the needle base during needle insertion via the master/slave system. Subjects were able to determine the position of the embedded membranes with significantly better accuracy using FBG tip feedback than with base feedback using a commercial force/torque sensor (p = 0.045) or with no added haptic feedback (p = 0.0024).

  7. Computerized automatic tip scanning operation

    International Nuclear Information System (INIS)

    Nishikawa, K.; Fukushima, T.; Nakai, H.; Yanagisawa, A.

    1984-01-01

    In BWR nuclear power stations the Traversing Incore Probe (TIP) system is one of the most important components in reactor monitoring and control. In previous TIP systems, however, operators have suffered from the complexity of operation and long operation time required. The system presented in this paper realizes the automatic operation of the TIP system by monitoring and driving it with a process computer. This system significantly reduces the burden on customer operators and improves plant efficiency by simplifying the operating procedure, augmenting the accuracy of the measured data, and shortening operating time. The process computer is one of the PODIA (Plant Operation by Displayed Information Automation) systems. This computer transfers control signals to the TIP control panel, which in turn drives equipment by microprocessor control. The process computer contains such components as the CRT/KB unit, the printer plotter, the hard copier, and the message typers required for efficient man-machine communications. Its operation and interface properties are described

  8. Study of tip loss corrections using CFD rotor computations

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zhu, Wei Jun; Sørensen, Jens Nørkær

    2014-01-01

    Tip loss correction is known to play an important role for engineering prediction of wind turbine performance. There are two different types of tip loss corrections: tip corrections on momentum theory and tip corrections on airfoil data. In this paper, we study the latter using detailed CFD...... computations for wind turbines with sharp tip. Using the technique of determination of angle of attack and the CFD results for a NordTank 500 kW rotor, airfoil data are extracted and a new tip loss function on airfoil data is derived. To validate, BEM computations with the new tip loss function are carried out...... and compared with CFD results for the NordTank 500 kW turbine and the NREL 5 MW turbine. Comparisons show that BEM with the new tip loss function can predict correctly the loading near the blade tip....

  9. [TIPS

    Science.gov (United States)

    Brazzini, Augusto; Carrillo, Alvaro; Cantella, Raúl

    1998-01-01

    Esophageal hemorrage due to variceal bleeding in cirrhotic patients represents a serious problem for the physician in charge, especially in this country where liver transplants are inexistent; and also, it is a drama for the patient and its familly. We propose here the Transjugular Intrahepatic Portosystemic Shunt (TIPS). Twenty one patients were part of a study where 23 TIPS were placed, observing an immediate improval in 18 of them, a rebleeding in 2, within the first 24 and 48 hours. An embolization of the coronary veins was performed in the procedure in 15 patients, and a second intervention due to rebleeding in 2 of them. In the latter patients, the embolization of the coronary veins was rutinary.The survival of the patients has been outstanding.We conclude that this interventional procedure is a worldwide reality in the treatment of esophageal hemorrage by variceal bleeding due to portal hipertension, and it does not cut down the probability of liver transplant, unfortunately inexistent in our country. This procedure results in a low morbimortality with an adequate quality of life.

  10. Espacios alternativos: Poesía y sujeto poético en el "Coloquio de los centauros" de Rubén Darío

    Directory of Open Access Journals (Sweden)

    Daniela Evangelina Chazarreta

    2011-11-01

    Full Text Available En este artículo analizamos el "Coloquio de los centauros" de Rubén Darío dando cuenta de los diversos procesos de apropiación de la tradición vigentes en la literatura latinoamericana así como de las operaciones del modernismo hispanoamericano allí presentes que traducen la incorporación de América Latina a la modernidad

  11. Variations the diameter tip of electrode on the resistance spot welding using electrode Cu on worksheet Fe

    Science.gov (United States)

    Baskoro, A. S.; Sugeng, S.; Sifa, Agus; Badruzzaman; Endramawan, Tito

    2018-04-01

    Resistance Spot Weld (RSW) is a welding technology which plays an important role that is often used in industry in large manufacturing industries, especially in the automotive sector, some of the parameters are affecting the welding process that give impact in the weld quality, diameter tip important impact on the resistance spot welding, This study can be categorized as experimental study by using Electrode material such as Cu and Fe Worksheet Materials, with a material thickness of 1 mm,0,8 mm, and 0,6 mm on each worksheet, and the large diameter of tip electrode (5√t) depend on the thickness of worksheet. Testing the material in the electrode and the worksheet by testing the composition and tensile test, and the hardness of the material used are to know the material used certainly. The result of the welding process was done by using the parameters voltage of 8KV, with a duty cycle of 50% using a variation of the time 8s-10s, and variations the electrode tip diameter that are affected by the thickness of the worksheet 5\\sqrt{t}, plate thickness used 1 mm, 0,8 mm and 0,6 mm, so that the electrodes was used to a thickness of 1 mm diameter tip electrode 5 mm, thickness 0,8 mm with an electrode tip diameter 4,5 mm and a thickness 0,6 mm with an electrode diameter of 4 mm, with current welding parameter 8kVA, and variations in holding time 10s, 9s and 8s 50% duty cycle, then testing welds with the standard shear test refers ASTM A370-2012 with more results to a thickness of 0,6 has the ability to withstand greater load on the holding time 8s and 9s, 10s, to a thickness 0,8 mm and 1 mm shear test results demonstrate the ability to withstand loads on the holding time of 10s and 9s have a greater ability than 8s on worksheet that has thickness 1 mm at a holding time of 10s, and then Maximum shear test averaging of 36,41 N at a worksheet with a thickness of 0,8 mm (diameter tip 4,5 mm) at a holding time of 8s and a mean minimum shear stress of 23,73 N at worksheet that

  12. CPAP Tips

    Medline Plus

    Full Text Available ... opinion count. Sign in ... and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ...

  13. The tonoplast intrinsic aquaporin (TIP) subfamily of Eucalyptus grandis: Characterization of EgTIP2, a root-specific and osmotic stress-responsive gene.

    Science.gov (United States)

    Rodrigues, Marcela I; Bravo, Juliana P; Sassaki, Flávio T; Severino, Fábio E; Maia, Ivan G

    2013-12-01

    Aquaporins have important roles in various physiological processes in plants, including growth, development and adaptation to stress. In this study, a gene encoding a root-specific tonoplast intrinsic aquaporin (TIP) from Eucalyptus grandis (named EgTIP2) was investigated. The root-specific expression of EgTIP2 was validated over a panel of five eucalyptus organ/tissues. In eucalyptus roots, EgTIP2 expression was significantly induced by osmotic stress imposed by PEG treatment. Histochemical analysis of transgenic tobacco lines (Nicotiana tabacum SR1) harboring an EgTIP2 promoter:GUS reporter cassette revealed major GUS staining in the vasculature and in root tips. Consistent with its osmotic-stress inducible expression in eucalyptus, EgTIP2 promoter activity was up-regulated by mannitol treatment, but was down-regulated by abscisic acid. Taken together, these results suggest that EgTIP2 might be involved in eucalyptus response to drought. Additional searches in the eucalyptus genome revealed the presence of four additional putative TIP coding genes, which could be individually assigned to the classical TIP1-5 groups. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Functionalization of atomic force microscope tips by dielectrophoretic assembly of Gd2O3:Eu3+ nanorods

    International Nuclear Information System (INIS)

    Macedo, Andreia G; Ananias, Duarte; Andre, Paulo S; Ferreira, Rute A sa; Carlos, Luis D; Kholkin, Andrei L; Rocha, J

    2008-01-01

    An atomic force microscopy (AFM) tip has been coated with photoluminescent Eu 3+ -doped Gd 2 O 3 nanorods using a dielectrophoresis technique, which preserves the red emission of the nanorods (quantum yield 0.47). The performance of the modified tips has been tested by using them for regular topography imaging in tapping and contact modes. Both a regular AFM standard grid and a patterned surface (of an organic-inorganic methacrylate Zr-based oxo-cluster and poly(oxyethylene)/siloxane hybrid) have been used. Similar depth values have been measured using a conventional silicon tip and the nanorod-modified tip. The tips before and after use exhibit similar SEM images and photoluminescence spectra and, thus, seem to be stable under working conditions. These tips should find applications in scanning near-field optical microscopy and other scanning techniques

  15. Tip Induced Motion of Adatoms on Metal Surfaces

    International Nuclear Information System (INIS)

    Kuerpick, U.; Rahman, T.S.

    1999-01-01

    From total energy calculations we show that for certain tip-adatom separations the activation barrier for the adatom to move towards the tip disappears and the adatom experiences an attractive force in the direction of the tip. For a Cu adatom at a (100) microfaceted step on Cu(111) this happens at a lateral separation of about one lattice constant, in agreement with recent experimental findings. Simultaneously, the activation barrier in the direction away from the tip increases significantly. The details of the changes in the potential energy surface induced by the tip are found to depend on the characteristics of the tip apex and its height above the adatom. copyright 1999 The American Physical Society

  16. Single macroscopic pillars as model system for bioinspired adhesives: influence of tip dimension, aspect ratio, and tilt angle.

    Science.gov (United States)

    Micciché, Maurizio; Arzt, Eduard; Kroner, Elmar

    2014-05-28

    The goal of our study is to better understand the design parameters of bioinspired dry adhesives inspired by geckos. For this, we fabricated single macroscopic pillars of 400 μm diameter with different aspect ratios and different tip shapes (i.e., flat tips, spherical tips with different radii, and mushroom tips with different diameters). Tilt-angle-dependent adhesion measurements showed that although the tip shape of the pillars strongly influences the pull-off force, the pull-off strength is similar for flat and mushroom-shaped tips. We found no tilt-angle dependency of adhesion for spherical tip structures and, except for high tilt angle and low preload experiments, no tilt-angle effect for mushroom-tip pillars. For flat-tip pillars, we found a strong influence of tilt angle on adhesion, which decreased linearly with increasing aspect ratio. The experiments show that for the tested aspect ratios between 1 and 5, a linear decrease of tilt-angle dependency is found. The results of our studies will help to design bioinspired adhesives for application on smooth and rough surfaces.

  17. A imunização contra a rubéola no primeiro trimestre de gestação pode levar à perda auditiva? Can the immunization against rubella take to the hearing loss in the first pregnancy quarter?

    Directory of Open Access Journals (Sweden)

    Ana L��cia Pereira de Andrade Dias

    2009-01-01

    Full Text Available TEMA: embora o risco da Síndrome da Rubéola Congênita após a imunização seja pequeno, é necessário assegurar a imunidade das mulheres em idade fértil, especialmente daquelas com risco mais alto de exposição, visando a prevenção. OBJETIVO: esclarecer o risco que a imunização da rubéola apresenta para a audição do recém nascido, no primeiro trimestre de gestação. CONCLUSÃO: os levantamentos realizados por este estudo permitiram concluir que ainda há um grande caminho a ser percorrido em prol da erradicação da rubéola no Brasil, bem como a diminuição dos riscos de surdez neurossensorial causados pela Síndrome da Rubéola Congênita.BACKGROUND: although congenital rubella syndrome risk after immunization is low, it is required to assert immunity of women in fertile age, especially those in higher risk of exposure aiming at prevention. PURPOSE: to elucidate the risk that rubella immunization in the first three months of gestation presents for the newborn hearing. CONCLUSION: investigations carried out by this study allow us to conclude that there is still a lot to be done in order to eradicate rubella in Brazil, as well as to reduce/decrease risks of neurosensorial deafness caused by CRS.

  18. Arctic tipping points in an Earth system perspective.

    Science.gov (United States)

    Wassmann, Paul; Lenton, Timothy M

    2012-02-01

    We provide an introduction to the volume The Arctic in the Earth System perspective: the role of tipping points. The terms tipping point and tipping element are described and their role in current science, general debates, and the Arctic are elucidated. From a wider perspective, the volume focuses upon the role of humans in the Arctic component of the Earth system and in particular the envelope for human existence, the Arctic ecosystems. The Arctic climate tipping elements, the tipping elements in Arctic ecosystems and societies, and the challenges of governance and anticipation are illuminated through short summaries of eight publications that derive from the Arctic Frontiers conference in 2011 and the EU FP7 project Arctic Tipping Points. Then some ideas based upon resilience thinking are developed to show how wise system management could ease pressures on Arctic systems in order to keep them away from tipping points.

  19. Modeling shoot-tip temperature in the greenhouse environment

    International Nuclear Information System (INIS)

    Faust, J.E.; Heins, R.D.

    1998-01-01

    An energy-balance model is described that predicts vinca (Catharanthus roseus L.) shoot-tip temperature using four environmental measurements: solar radiation and dry bulb, wet bulb, and glazing material temperature. The time and magnitude of the differences between shoot-tip and air temperature were determined in greenhouses maintained at air temperatures of 15, 20, 25, 30, or 35 °C. At night, shoot-tip temperature was always below air temperature. Shoot-tip temperature decreased from 0.5 to 5 °C below air temperature as greenhouse glass temperature decreased from 2 to 15 °C below air temperature. During the photoperiod under low vapor-pressure deficit (VPD) and low air temperature, shoot-tip temperature increased ≈4 °C as solar radiation increased from 0 to 600 W·m -2 . Under high VPD and high air temperature, shoot-tip temperature initially decreased 1 to 2 °C at sunrise, then increased later in the morning as solar radiation increased. The model predicted shoot-tip temperatures within ±1 °C of 81% of the observed 1-hour average shoot-tip temperatures. The model was used to simulate shoot-tip temperatures under different VPD, solar radiation, and air temperatures. Since the rate of leaf and flower development are influenced by the temperature of the meristematic tissues, a model of shoot-tip temperature will be a valuable tool to predict plant development in greenhouses and to control the greenhouse environment based on a plant temperature setpoint. (author)

  20. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  1. Tips for Postpartum Dads and Partners

    Science.gov (United States)

    ... Blues: Partners Interview with Wade Bowen Coping with Suicide & Loss Tips for Postpartum Dads and Partners Pregnancy and postpartum mood and anxiety disorders affect the whole family. Here are some tips ...

  2. Tipping Point

    Medline Plus

    Full Text Available ... fall furniture head injury product safety television tipover tv Watch the video in Adobe Flash format. Almost ... accidents involving young children and furniture, appliance and tv tip-overs. The force of a large television ...

  3. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely and effectively use your CPAP device. Category Education License Standard YouTube License Show more Show ...

  4. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  5. Tipping Point

    Medline Plus

    Full Text Available ... of a large television falling from tipping furniture can be staggering. A 50 lb. TV falls with ... story of a building. That kind of impact can kill a child or cause severe injuries. About ...

  6. A Rotor Tip Vortex Tracing Algorithm for Image Post-Processing

    Science.gov (United States)

    Overmeyer, Austin D.

    2015-01-01

    A neurite tracing algorithm, originally developed for medical image processing, was used to trace the location of the rotor tip vortex in density gradient flow visualization images. The tracing algorithm was applied to several representative test images to form case studies. The accuracy of the tracing algorithm was compared to two current methods including a manual point and click method and a cross-correlation template method. It is shown that the neurite tracing algorithm can reduce the post-processing time to trace the vortex by a factor of 10 to 15 without compromising the accuracy of the tip vortex location compared to other methods presented in literature.

  7. Characteristics of fracture during the approach process and wear mechanism of a silicon AFM tip

    International Nuclear Information System (INIS)

    Chung, Koo-Hyun; Lee, Yong-Ha; Kim, Dae-Eun

    2005-01-01

    The wear of an atomic force microscope (AFM) tip is one of the crucial issues in AFM as well as in other probe-based applications. In this work, wear tests under extremely low normal load using an AFM were conducted. Also, in order to understand the nature of silicon tip wear, the wear characteristics of crystal silicon and amorphous silicon oxide layer were investigated by a high-resolution transmission electron microscope (HRTEM). It was found that fracture of the tip readily occurred due to impact during the approach process. Experimental results showed that the impact should be below 0.1 nN s to avoid significant fracture of the tip. Also, it was observed that wear of the amorphous layer, formed at the end of the tip, occurred at the initial stage of the silicon tip damage process. Based on Archard's wear law, the wear coefficient of the amorphous layer was in the range of 0.009-0.014. As for the wear characteristics of the silicon tip, it was shown that wear occurred gradually under light normal load and the wear rate decreased with increase in the sliding distance. As for the wear mechanism of the silicon tip, oxidation wear was identified to be the most significant. It was shown that the degree of oxidation was higher under high normal load and in a nitrogen environment, oxidation of the silicon tip was reduced

  8. CPAP Tips

    Medline Plus

    Full Text Available ... sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely and effectively use your CPAP device. Category ... Ambulance Service 21,588 views 4:34 Obstructive Sleep Apnea ...

  9. Tipping Point

    Medline Plus

    Full Text Available ... third story of a building. That kind of impact can kill a child or cause severe injuries. ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit ...

  10. Continuum damage mechanics analysis of crack tip zone

    International Nuclear Information System (INIS)

    Yinchu, L.; Jianping, Z.

    1989-01-01

    The crack tip field and its intensity factor play an important role in fracture mechanics. Generally, the damage such as microcracks, microvoids etc. will initiate and grow in materials as the cracked body is subjected to external loadings, especially in the crack tip zone. The damage evolution will load to the crack tip damage field and the change of the stress, strain and displacement fields of cracks tip zone. In this paper, on the basis of continuum damage mechanics, the authors have derived the equations which the crack tip field and its intensity factor must satisfy in a loading process, calculated the angle distribution curves of stress, strain and displacement fields in a crack tip zone and have compared them with the corresponding curves of HRR field and linear elastic field in undamaged materials. The equations of crack tip field intensity factors have been solved and its solutions give the variation of the field intensity factors with the loading parameter

  11. Tip enhancement

    CERN Document Server

    Kawata, Satoshi

    2007-01-01

    This book discusses the recent advances in the area of near-field Raman scattering, mainly focusing on tip-enhanced and surface-enhanced Raman scattering. Some of the key features covered here are the optical structuring and manipulations, single molecule sensitivity, analysis of single-walled carbon nanotubes, and analytic applications in chemistry, biology and material sciences. This book also discusses the plasmonic materials for better enhancement, and optical antennas. Further, near-field microscopy based on second harmonic generation is also discussed. Chapters have been written by some of the leading scientists in this field, who present some of their recent work in this field.·Near-field Raman scattering·Tip-enhanced Raman spectroscopy·Surface-enhanced Raman spectroscopy·Nano-photonics·Nanoanalysis of Physical, chemical and biological materials beyond the diffraction limits·Single molecule detection

  12. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  13. Micronucleus test of varying amounts of potassium bromate (KBrO3) on the meristematic cells of Allium cepa var. aggregatum root tips

    International Nuclear Information System (INIS)

    Cajigal Romnick, M.; Somera, Leomerto A.

    1999-03-01

    Four hundred twenty onion bulbs of the multiplier variety Allium cepa var. aggregatum were used as test materials to assay the micronucleus induction capacity of potassium bromate doses of 0, 5, 10, 25, 50, 75, and 100 parts per million. Microscopic analyses were done using onion root tips prepared according to a modified technique of Medina (1994). These analyses were done on root tips taken from onions grown in KBrO 3 for three days and for five days. The study was conducted following a completely randomized design and the data were statistically analyzed using a non-parametric equivalent of the analysis of variance. A significant amount of micronucleated cells (MCN) were found among treated onions compared with the almost non-occurrence in the control groups (0 ppm). The Kruskal-Wallis H-test and the Wilcoxon two-samples tests revealed significant differences among treatment means and that a significant increase in the number of MCN occurs as the dose of KBr0 3 increased in both day experiments. Results from the higher doses of 50, 75, and 100 ppm were found to be significantly the same for the day 3 experiments while those of the day 5 higher doses are characterized by lack of clear cellular and nuclear outline such that scoring is difficult. Differences in MCN averages for the day 3 and 5 experiments appear to be insignificant. However, day 3 results show averages that are more significantly different from each other. These prove that the MCN can be used as an efficient and time-saving parameter for the allium test of chemicals with chromosome breaking capacities. (Author)

  14. Optical fiber meta-tips

    Science.gov (United States)

    Principe, Maria; Micco, Alberto; Crescitelli, Alessio; Castaldi, Giuseppe; Consales, Marco; Esposito, Emanuela; La Ferrara, Vera; Galdi, Vincenzo; Cusano, Andrea

    2016-04-01

    We report on the first example of a "meta-tip" configuration that integrates a metasurface on the tip of an optical fiber. Our proposed design is based on an inverted-Babinet plasmonic metasurface obtained by patterning (via focused ion beam) a thin gold film deposited on the tip of an optical fiber, so as to realize an array of rectangular aperture nanoantennas with spatially modulated sizes. By properly tuning the resonances of the aperture nanoantennas, abrupt variations can be impressed in the field wavefront and polarization. We fabricated and characterized several proof-of-principle prototypes operating an near-infrared wavelengths, and implementing the beam-steering (with various angles) of the cross-polarized component, as well as the excitation of surface waves. Our results pave the way to the integration of the exceptional field-manipulation capabilities enabled by metasurfaces with the versatility and ubiquity of fiber-optics technological platforms.

  15. CPAP Tips

    Medline Plus

    Full Text Available ... Get YouTube Red. Working... Not now Try it free Find out why Close CPAP Tips from FDA ... safely and effectively use your CPAP device. Category Education License Standard YouTube License Show more Show less ...

  16. Note: Microelectrode-shielding tip for scanning probe electron energy spectroscopy

    Science.gov (United States)

    Huang, Wei; Li, Zhean; Xu, Chunkai; Liu, Jian; Xu, Chunye; Chen, Xiangjun

    2018-04-01

    We report a novel microelectrode-shielding tip (ME tip) for scanning probe electron energy spectroscopy (SPEES). The shielding effect of this tip is studied through comparing the detection efficiency with the normal tip by both experiment and simulation. The results show that the backscattering count rate detected by the SPEES instrument using the normal tip begins to decrease as the tip approaches to the sample surface within 21 μm, while that using the ME tip only starts to drop off within 1 μm. This indicates that the electron energy spectra can be measured with the ME tip at a much closer tip-sample distance. Furthermore, it is also demonstrated that the ME tip can be used to obtain topography of the sample surface in situ simultaneously.

  17. A new reference tip-timing test bench and simulator for blade synchronous and asynchronous vibrations

    Science.gov (United States)

    Hajnayeb, Ali; Nikpour, Masood; Moradi, Shapour; Rossi, Gianluca

    2018-02-01

    The blade tip-timing (BTT) measurement technique is at present the most promising technique for monitoring the blades of axial turbines and aircraft engines in operating conditions. It is generally used as an alternative to strain gauges in turbine testing. By conducting a comparison with the standard methods such as those based on strain gauges, one determines that the technique is not intrusive and does not require a complicated installation process. Despite its superiority to other methods, the experimental performance analysis of a new BTT method needs a test stand that includes a reference measurement system (e.g. strain gauges equipped with telemetry or other complex optical measurement systems, like rotating laser Doppler vibrometers). In this article, a new reliable, low-cost BTT test setup is proposed for simulating and analyzing blade vibrations based on kinematic inversion. In the proposed test bench, instead of the blades vibrating, it is the BTT sensor that vibrates. The vibration of the sensor is generated by a shaker and can therefore be easily controlled in terms of frequency, amplitude and waveform shape. The amplitude of vibration excitation is measured by a simple accelerometer. After introducing the components of the simulator, the proposed test bench is used in practice to simulate both synchronous and asynchronous vibration scenarios. Then two BTT methods are used to evaluate the quality of the acquired data. The results demonstrate that the proposed setup is able to generate simulated pulse sequences which are almost the same as those generated by the conventional BTT systems installed around a bladed disk. Moreover, the test setup enables its users to evaluate BTT methods by using a limited number of sensors. This significantly reduces the total costs of the experiments.

  18. Injector tip for an internal combustion engine

    Science.gov (United States)

    Shyu, Tsu Pin; Ye, Wen

    2003-05-20

    This invention relates to a the tip structure of a fuel injector as used in a internal combustion engine. Internal combustion engines using Homogeneous Charge Compression Ignition (HCCI) technology require a tip structure that directs fuel spray in a downward direction. This requirement necessitates a tip design that is capable of withstanding mechanical stresses associated with the design.

  19. Modification of AFM Tips for Facilitating Picking-up of Nanoparticles

    International Nuclear Information System (INIS)

    Peng, Wang; Hai-Jun, Yang; Hua-Bin, Wang; Hai, Li; Xin-Yan, Wang; Ying, Wang; Jun-Hong, Lü; Bin, Li; Yi, Zhang; Jun, Hu

    2008-01-01

    The radius of atomic force microscope (AFM) tip is a key factor that influences nonspecific interactions between AFM tip and nanoparticles. Generally, a tip with larger radius contributes to a higher efficiency of picking up nanoparticles. We provide two methods for modifying the AFM tip: one is to wear a tip apex on a solid substrate and the other is to coat a tip with poly (dimethylsiloxane) (PDMS). Both the approaches can enhance the adhesion force between the tip and nanoparticles by increasing tip radius. The experimental results show that a modified tip, compared to an unmodified one, achieves six-fold efficiency improvement in the capture of targeted colloidal gold nanoparticles. (general)

  20. Dynamic of cold-atom tips in anharmonic potentials

    Science.gov (United States)

    Menold, Tobias; Federsel, Peter; Rogulj, Carola; Hölscher, Hendrik; Fortágh, József

    2016-01-01

    Background: Understanding the dynamics of ultracold quantum gases in an anharmonic potential is essential for applications in the new field of cold-atom scanning probe microscopy. Therein, cold atomic ensembles are used as sensitive probe tips to investigate nanostructured surfaces and surface-near potentials, which typically cause anharmonic tip motion. Results: Besides a theoretical description of this anharmonic tip motion, we introduce a novel method for detecting the cold-atom tip dynamics in situ and real time. In agreement with theory, the first measurements show that particle interactions and anharmonic motion have a significant impact on the tip dynamics. Conclusion: Our findings will be crucial for the realization of high-sensitivity force spectroscopy with cold-atom tips and could possibly allow for the development of advanced spectroscopic techniques such as Q-control. PMID:28144505

  1. Identificación de infección primaria y secundaria al virus de la rubéola mediante la detección de la avidez de la IgG en muestras de un brote en el 2004 en Cuba

    Directory of Open Access Journals (Sweden)

    Yahisel Tejero

    2013-12-01

    Full Text Available La rubéola es una enfermedad infectocontagiosa que afecta a niños y adultos jóvenes, y cuando esta se produce en el primer trimestre del embarazo ocasiona malformaciones congénitas en el feto. En el Laboratorio Nacional de Referencia de Sarampión, Rubéola y Parotiditis del Instituto de Medicina Tropical "Pedro Kourí", se realizó la detección del índice de avidez relativo (IAR de la IgG en 15 pares de sueros correspondientes a igual número de pacientes adultos que enfermaron durante un brote de rubéola ocurrido en dos provincias de Cuba en el 2004, los cuales fueron positivos a anticuerpos de tipo IgM específicos al virus, y en algunos se encontró seroconversión o un aumento de cuatro veces el título entre los sueros de la fase aguda y convaleciente con la técnica de inhibición de la hemaglutinación. En 13 (86,6% de los pacientes estudiados se detectó infección primaria, mientras que en dos (13,3% de ellos la infección fue secundaria. La detección de la avidez de la IgG constituye un método alternativo útil para distinguir una infección primaria de una secundaria al virus de la rubéola y fortalece el diagnóstico de esta enfermedad en Cuba.

  2. CPAP Tips

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close CPAP Tips from ...

  3. Direct calculation of wind turbine tip loss

    DEFF Research Database (Denmark)

    Wood, D.H.; Okulov, Valery; Bhattacharjee, D.

    2016-01-01

    . We develop three methods for the direct calculation of the tip loss. The first is the computationally expensive calculation of the velocities induced by the helicoidal wake which requires the evaluation of infinite sums of products of Bessel functions. The second uses the asymptotic evaluation......The usual method to account for a finite number of blades in blade element calculations of wind turbine performance is through a tip loss factor. Most analyses use the tip loss approximation due to Prandtl which is easily and cheaply calculated but is known to be inaccurate at low tip speed ratio...

  4. Biaxial loading and shallow-flaw effects on crack-tip constraint and fracture toughness

    International Nuclear Information System (INIS)

    Bass, B.R.; Bryson, J.W.; Theiss, T.J.; Rao, M.C.

    1994-01-01

    A program to develop and evaluate fracture methodologies for the assessment of crack-tip constraint effects on fracture toughness of reactor pressure vessel (RPV) steels has been initiated in the Heavy-Section Steel Technology (HSST) Program. Crack-tip constraint is an issue that significantly impacts fracture mechanics technologies employed in safety assessment procedures for commercially licensed nuclear RPVs. The focus of studies described herein is on the evaluation of two stressed-based methodologies for quantifying crack-tip constraint (i.e., J-Q theory and a micromechanical scaling model based on critical stressed volumes) through applications to experimental and fractographic data. Data were utilized from single-edge notch bend (SENB) specimens and HSST-developed cruciform beam specimens that were tested in HSST shallow-crack and biaxial testing programs. Results from applications indicate that both the J-Q methodology and the micromechanical scaling model can be used successfully to interpret experimental data from the shallow- and deep-crack SENB specimen tests. When applied to the uniaxially and biaxially loaded cruciform specimens, the two methodologies showed some promising features, but also raised several questions concerning the interpretation of constraint conditions in the specimen based on near-tip stress fields. Fractographic data taken from the fracture surfaces of the SENB and cruciform specimens are used to assess the relevance of stress-based fracture characterizations to conditions at cleavage initiation sites. Unresolved issues identified from these analyses require resolution as part of a validation process for biaxial loading applications. This report is designated as HSST Report No. 142

  5. Vigilancia microbiológica del sarampión y la rubéola en España: red de laboratorios

    OpenAIRE

    Echevarría, Juan Emilio; Fernández García, Aurora; Ory, Fernando de

    2015-01-01

    El laboratorio es un elemento imprescindible en la vigilancia del sarampión y la rubéola, ya que los casos han de ser adecuadamente confirmados para poder estimar la incidencia de forma precisa, las cepas han de ser caracterizadas genéticamente para conocer el patrón de circulación de los virus y estudiar de forma completa los brotes y las cadenas de transmisión y la susceptibilidad de la población debe de ser determinada mediante encuestas de seroprevalencia. El diagnóstico de laboratorio de...

  6. Management of Bleeding Duodenal Varices with Combined TIPS Decompression and Trans-TIPS Transvenous Obliteration Utilizing 3% Sodium Tetradecyl Sulfate Foam Sclerosis.

    Science.gov (United States)

    Saad, Wael E; Lippert, Allison; Schwaner, Sandra; Al-Osaimi, Abdullah; Sabri, Saher; Saad, Nael

    2014-01-01

    Endoscopic experience in the management of duodenal varices (DVs) is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS) or by transvenous obliteration is unresolved. In the literature, the 6-12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. This is a retrospective study (case series) of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013). TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis) from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs) and clinical outcomes (rebleeding rate and survival) were evaluated. Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally) receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days). After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6-50 months). Coils and/or metallic vascular plugs were used to augment

  7. Effects of a Nonuniform Tip Clearance Profile on the Performance and Flow Field in a Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Yohan Jung

    2012-01-01

    Full Text Available This paper presents a numerical investigation of the effects of a nonuniform tip clearance profile on the performance and flow field in a centrifugal compressor with a vaneless diffuser. This study focuses in particular on the magnitude and location of the wake. Six impellers with different tip clearance profiles were tested in the flow simulations. The accuracy of the numerical simulations was assessed by comparing the experimental data with the computational results for a system characterized by the original tip clearance. Although the performance improved for low tip clearances, a low tip clearance at the trailing edge improved the compressor performance more significantly than a low tip clearance at the leading edge. The flow field calculated for a system characterized by a low tip clearance at the trailing edge produced a more uniform velocity distribution both in the circumferential and in the axial directions at the impeller exit because the wake magnitude was reduced. As a consequence, this impeller provided a better potential for diffusion processes inside a vaneless diffuser.

  8. Hard-tip, soft-spring lithography.

    Science.gov (United States)

    Shim, Wooyoung; Braunschweig, Adam B; Liao, Xing; Chai, Jinan; Lim, Jong Kuk; Zheng, Gengfeng; Mirkin, Chad A

    2011-01-27

    Nanofabrication strategies are becoming increasingly expensive and equipment-intensive, and consequently less accessible to researchers. As an alternative, scanning probe lithography has become a popular means of preparing nanoscale structures, in part owing to its relatively low cost and high resolution, and a registration accuracy that exceeds most existing technologies. However, increasing the throughput of cantilever-based scanning probe systems while maintaining their resolution and registration advantages has from the outset been a significant challenge. Even with impressive recent advances in cantilever array design, such arrays tend to be highly specialized for a given application, expensive, and often difficult to implement. It is therefore difficult to imagine commercially viable production methods based on scanning probe systems that rely on conventional cantilevers. Here we describe a low-cost and scalable cantilever-free tip-based nanopatterning method that uses an array of hard silicon tips mounted onto an elastomeric backing. This method-which we term hard-tip, soft-spring lithography-overcomes the throughput problems of cantilever-based scanning probe systems and the resolution limits imposed by the use of elastomeric stamps and tips: it is capable of delivering materials or energy to a surface to create arbitrary patterns of features with sub-50-nm resolution over centimetre-scale areas. We argue that hard-tip, soft-spring lithography is a versatile nanolithography strategy that should be widely adopted by academic and industrial researchers for rapid prototyping applications.

  9. Numerical Simulation of LVAD Inflow Cannulas with Different Tip

    Directory of Open Access Journals (Sweden)

    Guang-Mao Liu

    2012-01-01

    Full Text Available The tip structure of LVAD inflow cannula is one of major factors to lead adverse events such as thrombosis and suction leading to obstruction. In this research, four kinds of tips that had been used in inflow cannulas were selected and designed. The flow field of the four inflow cannulas inserted into the apex of left ventricle (LV was numerically computed by computational fluid dynamics. The flow behavior was analyzed in order to compare the blood compatibility and suction in left ventricle and cannulas after the inflow cannulas with different tips were inserted to the apex of LV. The results showed that the cannula tip structure affected the LVAD performance. Among these four cannulas, the trumpet-tipped inflow cannula owned the best performance in smooth flow velocity distribution without backflow or low-velocity flow so that it was the best in blood compatibility. Nevertheless, the caged tipped cannula was the worst in blood compatibility. And the blunt-tipped and beveled tipped inflow cannulas may obstruct more easily than trumpet and caged tipped inflow cannulas because of their shape. The study indicated that the trumpet tip was the most preferable for the inflow cannula of long-term LVAD.

  10. Aerodynamic performance of winglets covering the tip gap inlet in a turbine cascade

    International Nuclear Information System (INIS)

    Lee, Sang Woo; Kim, Seon Ung; Kim, Kyoung Hoon

    2012-01-01

    Highlights: ► We test aerodynamics of PS and LEPS winglets for three winglet widths. ► PS winglet reduces tip leakage loss but increases loss in the passage vortex region. ► Mass-averaged loss reductions by PS and LEPS winglets are marginal. ► The loss reductions are much smaller than that by a cavity squealer tip. - Abstract: The aerodynamic performance of two different kinds of winglets covering the tip gap inlet of a plane tip, a “pressure-side” (PS) winglet and a “leading-edge and pressure-side” (LEPS) winglet, has been investigated in a turbine cascade. For a tip gap height-to-chord ratio of h/c = 2.0%, their width-to-pitch ratio is changed to be w/p = 2.64, 5.28, and 10.55%. The PS winglet reduces aerodynamic loss in the tip leakage vortex region as well as in an area downstream of the winglet-pressure surface corner, whereas it increases aerodynamic loss in the central area of the passage vortex region. The additional leading-edge winglet portion of the LEPS winglet reduces aerodynamic loss considerably on the casing wall side of the passage vortex region but delivers a noticeable aerodynamic loss increase on its mid-span side. These local trends are deepened with increasing w/p. However, the mass-averaged aerodynamic loss reductions by installing the PS and LEPS winglets in comparison with the baseline no winglet data are only marginal even for w/p = 10.55% and found much smaller than that by employing a cavity squealer tip.

  11. Effect of multiple alcohol-based hand rub applications on the tensile properties of thirteen brands of medical exam nitrile and latex gloves.

    Science.gov (United States)

    Gao, Pengfei; Horvatin, Matthew; Niezgoda, George; Weible, Robyn; Shaffer, Ronald

    2016-12-01

    Current CDC guidance for the disinfection of gloved hands during the doffing of personal protective equipment (PPE) following the care of a patient with Ebola recommends for multiple applications of alcohol-based hand rub (ABHR) on medical exam gloves. To evaluate possible effects of ABHR applications on glove integrity, thirteen brands of nitrile and latex medical exam gloves from five manufacturers and two different ABHRs were included in this study. A pair of gloves were worn by a test operator and the outside surfaces of the gloves were separately treated with an ABHR for 1-6 applications. Tensile strength and ultimate elongation of the gloves without any ABHR treatments (control gloves) and gloves after 1-6 ABHR applications were measured based on the ASTM D412 standard method. In general, tensile strength decreased with each ABHR application. ABHRs had more effect on the tensile strength of the tested nitrile than latex gloves, while ethanol-based ABHR (EBHR) resulted in lesser changes in tensile strength compared to isopropanol-based ABHR (IBHR). The results show that multiple EBHR applications on the latex gloves and some of the nitrile gloves tested should be safe for Ebola PPE doffing based on the CDC guidance. Appropriate hospital staff practice using ABHR treatment and doffing gloves is recommended to become more familiar with changes in glove properties.

  12. Optimization and design of an aircraft's morphing wing-tip demonstrator for drag reduction at low speeds, Part II - Experimental validation using Infra-Red transition measurement from Wind Tunnel tests

    Directory of Open Access Journals (Sweden)

    Andreea Koreanschi

    2017-02-01

    Full Text Available In the present paper, an ‘in-house’ genetic algorithm was numerically and experimentally validated. The genetic algorithm was applied to an optimization problem for improving the aerodynamic performances of an aircraft wing tip through upper surface morphing. The optimization was performed for 16 flight cases expressed in terms of various combinations of speeds, angles of attack and aileron deflections. The displacements resulted from the optimization were used during the wind tunnel tests of the wing tip demonstrator for the actuators control to change the upper surface shape of the wing. The results of the optimization of the flow behavior for the airfoil morphing upper-surface problem were validated with wind tunnel experimental transition results obtained with infra-red Thermography on the wing-tip demonstrator. The validation proved that the 2D numerical optimization using the ‘in-house’ genetic algorithm was an appropriate tool in improving various aspects of a wing’s aerodynamic performances.

  13. Productivity tips for developers

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    I like to read about productivity tools and techniques, but the problem is - most of them are completely overrated, the tips are not that useful or they are too difficult to implement. But, sometimes I can find some stuff that really makes me think "damn, how could I live without this before?!". Today, I would like to share some of them and hopefully hear about the tips and tricks that you use. Maybe we can find a way to share them somehow (github repo/forum)?

  14. Temperature-controlled irrigated tip radiofrequency catheter ablation

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, Adrian

    1998-01-01

    INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion......: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip....

  15. Tipping Point

    Medline Plus

    Full Text Available ... to prevent a tip-over tragedy. Share Post Facebook Twitter Google Plus Reddit Connect with Me:  Visit other Web Sites Maintained by CPSC: cpsc.gov| poolsafely.gov| recalls.gov| saferproducts.gov Privacy, Security, and Legal Notice | Accessibility Policy | Open Government @ ...

  16. TIPS Evaluation Project Retrospective Study: Wave 1 and 2.

    Science.gov (United States)

    Hubbard, Susan M.; Mulvey, Kevin P.

    2003-01-01

    Measured substance abuse treatment professionals' knowledge, attitudes, and practices regarding the Treatment Improvement Protocol (TIP) series and the 28 TIPs. Results for 3,267 respondents in wave 1 and 1,028 in wave 2 indicate that almost half of all professionals were aware of the TIPs. Attitudes toward TIPs were positive, but professionals…

  17. Management of Bleeding Duodenal Varices with Combined TIPS Decompression and Trans-TIPS Transvenous Obliteration Utilizing 3% Sodium Tetradecyl Sulfate Foam Sclerosis

    Directory of Open Access Journals (Sweden)

    Wael E Saad

    2014-01-01

    Full Text Available Objectives: Endoscopic experience in the management of duodenal varices (DVs is limited and challenging given the anatomic constraints and limited experience. The endovascular management of DVs is not yet established and the controversy of whether to manage them by decompression with a transjugular intrahepatic portosystemic shunt (TIPS or by transvenous obliteration is unresolved. In the literature, the 6-12 month rebleeding rate of DVs after TIPS is 21-37% and after transvenous obliteration is 13%. The purpose of the study is to evaluate the clinical outcome of combined TIPS decompression and transvenous obliteration/sclerosis. Materials and Methods: This is a retrospective study (case series of two institutions, evaluating patients who underwent TIPS and/or transvenous obliteration/sclerosis for bleeding DVs (from January 2009 to June 2013. TIPS was performed according to a standard procedure using covered stents. Transvenous obliteration (variceal sclerosis from the systemic and/or portal venous circulation was performed utilizing 3% sodium tetradecyl sulfate foam. Transvenous obliteration was commonly augmented with coils and/or vascular plugs. Technical (technical success of establishing TIPS and completely obliterating the DVs and clinical outcomes (rebleeding rate and survival were evaluated. Results: Five patients with liver cirrhosis presenting with bleeding DVs were included in the study with all eventually (and coincidentally receiving TIPS and transvenous obliteration. Two of the five patients underwent concomitant TIPS and transvenous obliteration in the same procedural setting. However, three patients underwent transvenous obliteration due to bleeding despite a patent TIPS that had been previously placed. The average time from TIPS placement to transvenous obliteration was 125 days (range: 3-324 days. After having both procedures, there was no rebleeding in the patients during a mean follow-up period of 22 months (6-50 months

  18. Magnetic elements for switching magnetization magnetic force microscopy tips

    International Nuclear Information System (INIS)

    Cambel, V.; Elias, P.; Gregusova, D.; Martaus, J.; Fedor, J.; Karapetrov, G.; Novosad, V.

    2010-01-01

    Using combination of micromagnetic calculations and magnetic force microscopy (MFM) imaging we find optimal parameters for novel magnetic tips suitable for switching magnetization MFM. Switching magnetization MFM is based on two-pass scanning atomic force microscopy with reversed tip magnetization between the scans. Within the technique the sum of the scanned data with reversed tip magnetization depicts local atomic forces, while their difference maps the local magnetic forces. Here we propose the design and calculate the magnetic properties of tips suitable for this scanning probe technique. We find that for best performance the spin-polarized tips must exhibit low magnetic moment, low switching fields, and single-domain state at remanence. The switching field of such tips is calculated and optimum shape of the Permalloy elements for the tips is found. We show excellent correspondence between calculated and experimental results for Py elements.

  19. Thermoelectric voltage at a nanometer-scale heated tip point contact

    Science.gov (United States)

    Fletcher, Patrick C.; Lee, Byeonghee; King, William P.

    2012-01-01

    We report thermoelectric voltage measurements between the platinum-coated tip of a heated atomic force microscope (AFM) cantilever and a gold-coated substrate. The cantilevers have an integrated heater-thermometer element made from doped single crystal silicon, and a platinum tip. The voltage can be measured at the tip, independent from the cantilever heating. We used the thermocouple junction between the platinum tip and the gold substrate to measure thermoelectric voltage during heating. Experiments used either sample-side or tip-side heating, over the temperature range 25-275 °C. The tip-substrate contact is ˜4 nm in diameter and its average measured Seebeck coefficient is 3.4 μV K-1. The thermoelectric voltage is used to determine tip-substrate interface temperature when the substrate is either glass or quartz. When the non-dimensional cantilever heater temperature is 1, the tip-substrate interface temperature is 0.593 on glass and 0.125 on quartz. Thermal contact resistance between the tip and the substrate heavily influences the tip-substrate interface temperature. Measurements agree well with modeling when the tip-substrate interface contact resistance is 108 K W-1.

  20. Anticorpos para os vírus da rubéola, do sarampo e da caxumba em crianças de São Paulo, Brasil Rubella, measles and mumps serum antibodies in children of S. Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Renato Piza de Souza Carvalho

    1976-12-01

    Full Text Available Foram dosados anticorpos inibidores da hemaglutinação para o vírus da rubéola, do sarampo e da caxumba, em amostras de soro de 166 crianças de elevado nível sócio-econômico, com idade de 6 a 12 anos, que freqüentavam, em 1969, uma escola primária na cidade de São Paulo, Brasil. A per-centagem de soros positivos foi de 49,3% para a rubéola, 88,2% para o sarampo e 79,4% para a caxumba. Através de interrogatório junto aos pais, observou-se significativa correspondência entre antecedentes clínicos positivos para sarampo e caxumba e presença de anticorpos circulantes (95,3% e 91,7%, respectivamente. Houve grande discordância quando os antecedentes clínicos ou vacinais para sarampo e caxumba eram negativos: 51,8% e 61,4% destas crianças possuíam anticorpos circulantes. Quanto à rubéola, não foi possível fazer-se tal correlação, pois a maioria das mães não sabia dar informações sobre esta doença, no passado.One hundred and sixty high socio-economic level, 6-12 year old children, attending a primary school, were tested in 1969 for rubella, measles and mumps HI antibodies. A 49.3% positivity for rubella antibodies, 88.2% for measles and 79.4% for mumps were found. A good correlation was observed between a positive history of clinical disease in the past and detectable serum antibodies for measles and mumps (95.3% and 91.7%, respectively. Quite on the contrary was observed when the history of measles and mumps disease or immunization in the past were negative, as 51.8% and 61.4% of these children, respectively, presented antibodies. As regards rubella, no correlation was obtained as the great majority of the parents was unable to give information on this disease in the past.

  1. Effects of plastic anisotropy on crack-tip behaviour

    DEFF Research Database (Denmark)

    Legarth, Brian Nyvang; Tvergaard, Viggo; Kuroda, Mitsutoshi

    2002-01-01

    For a crack in a homogeneous material the effect of plastic anisotropy on crack-tip blunting and on the near-tip stress and strain fields is analyzed numerically. The full finite strain analyses are carried out for plane strain under small scale yielding conditions, with purely symmetric mode I...... loading remote from the crack-tip. In cases where the principal axes of the anisotropy are inclined to the plane of the crack it is found that the plastic zones as well as the stress and strain fields just around the blunted tip of the crack become non-symmetric. In these cases the peak strain...... on the blunted tip occurs off the center line of the crack, thus indicating that the crack may want to grow in a different direction. When the anisotropic axes are parallel to the crack symmetry is retained, but the plastic zones and the near-tip fields still differ from those predicted by standard isotropic...

  2. Embolization with the Amplatzer Vascular Plug in TIPS Patients

    International Nuclear Information System (INIS)

    Pattynama, Peter M. T.; Wils, Alexandra; Linden, Edwin van der; Dijk, Lukas C. van

    2007-01-01

    Vessel embolization can be a valuable adjunct procedure in transjugular intrahepatic portosystemic shunt (TIPS). During the creation of a TIPS, embolization of portal vein collaterals supplying esophageal varices may lower the risk of secondary rebleeding. And after creation of a TIPS, closure of the TIPS itself may be indicated if the resulting hepatic encephalopathy severely impairs mental functioning. The Amplatzer Vascular Plug (AVP; AGA Medical, Golden Valley, MN) is well suited for embolization of large-diameter vessels and has been employed in a variety of vascular lesions including congenital arteriovenous shunts. Here we describe the use of the AVP in the context of TIPS to embolize portal vein collaterals (n = 8) or to occlude the TIPS (n = 2)

  3. Microneedles array with biodegradable tips for transdermal drug delivery

    Science.gov (United States)

    Iliescu, Ciprian; Chen, Bangtao; Wei, Jiashen; Tay, Francis E. H.

    2008-12-01

    The paper presented an enhancement solution for transdermal drug delivery using microneedles array with biodegradable tips. The microneedles array was fabricated by using deep reactive ion etching (DRIE) and the biodegradable tips were made to be porous by electrochemical etching process. The porous silicon microneedle tips can greatly enhance the transdermal drug delivery in a minimum invasion, painless, and convenient manner, at the same time; they are breakable and biodegradable. Basically, the main problem of the silicon microneedles consists of broken microneedles tips during the insertion. The solution proposed is to fabricate the microneedle tip from a biodegradable material - porous silicon. The silicon microneedles are fabricated using DRIE notching effect of reflected charges on mask. The process overcomes the difficulty in the undercut control of the tips during the classical isotropic silicon etching process. When the silicon tips were formed, the porous tips were then generated using a classical electrochemical anodization process in MeCN/HF/H2O solution. The paper presents the experimental results of in vitro release of calcein and BSA with animal skins using a microneedle array with biodegradable tips. Compared to the transdermal drug delivery without any enhancer, the microneedle array had presented significant enhancement of drug release.

  4. Micronucleus test of varying amounts of potassium bromate (KBrO{sub 3}) on the meristematic cells of Allium cepa var. aggregatum root tips

    Energy Technology Data Exchange (ETDEWEB)

    Cajigal Romnick, M; Somera, Leomerto A

    1999-03-01

    Four hundred twenty onion bulbs of the multiplier variety Allium cepa var. aggregatum were used as test materials to assay the micronucleus induction capacity of potassium bromate doses of 0, 5, 10, 25, 50, 75, and 100 parts per million. Microscopic analyses were done using onion root tips prepared according to a modified technique of Medina (1994). These analyses were done on root tips taken from onions grown in KBrO{sub 3} for three days and for five days. The study was conducted following a completely randomized design and the data were statistically analyzed using a non-parametric equivalent of the analysis of variance. A significant amount of micronucleated cells (MCN) were found among treated onions compared with the almost non-occurrence in the control groups (0 ppm). The Kruskal-Wallis H-test and the Wilcoxon two-samples tests revealed significant differences among treatment means and that a significant increase in the number of MCN occurs as the dose of KBr0{sub 3} increased in both day experiments. Results from the higher doses of 50, 75, and 100 ppm were found to be significantly the same for the day 3 experiments while those of the day 5 higher doses are characterized by lack of clear cellular and nuclear outline such that scoring is difficult. Differences in MCN averages for the day 3 and 5 experiments appear to be insignificant. However, day 3 results show averages that are more significantly different from each other. These prove that the MCN can be used as an efficient and time-saving parameter for the allium test of chemicals with chromosome breaking capacities. (Author)

  5. Crack tip stress and strain

    International Nuclear Information System (INIS)

    Francois, D.

    1975-01-01

    The study of potential energy variations in a loaded elastic solid containing a crack leads to determination of the crack driving force G. Generalization of this concept to cases other than linear elasticity leads to definition of the integral J. In a linear solid, the crack tip stress field is characterized by a single parameter: the stress-intensity factor K. When the crack tip plastic zone size is confined to the elastic singularity J=G, it is possible to establish relationship between these parameters and plastic strain (and in particular the crack tip opening displacement delta). The stress increases because of the triaxiality effect. This overload rises with increasing strain hardening. When the plastic zone size expands, using certain hypotheses, delta can be calculated. The plastic strain intensity is exclusively dependent on parameter J [fr

  6. Aerodynamic performance of winglets covering the tip gap inlet in a turbine cascade

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Woo, E-mail: swlee@kumoh.ac.kr [Department of Mechanical Engineering, Kumoh National Institute of Technology, 1 Yangho-dong, Gumi, Gyeongbuk 730-701 (Korea, Republic of); Kim, Seon Ung; Kim, Kyoung Hoon [Department of Mechanical Engineering, Kumoh National Institute of Technology, 1 Yangho-dong, Gumi, Gyeongbuk 730-701 (Korea, Republic of)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer We test aerodynamics of PS and LEPS winglets for three winglet widths. Black-Right-Pointing-Pointer PS winglet reduces tip leakage loss but increases loss in the passage vortex region. Black-Right-Pointing-Pointer Mass-averaged loss reductions by PS and LEPS winglets are marginal. Black-Right-Pointing-Pointer The loss reductions are much smaller than that by a cavity squealer tip. - Abstract: The aerodynamic performance of two different kinds of winglets covering the tip gap inlet of a plane tip, a 'pressure-side' (PS) winglet and a 'leading-edge and pressure-side' (LEPS) winglet, has been investigated in a turbine cascade. For a tip gap height-to-chord ratio of h/c = 2.0%, their width-to-pitch ratio is changed to be w/p = 2.64, 5.28, and 10.55%. The PS winglet reduces aerodynamic loss in the tip leakage vortex region as well as in an area downstream of the winglet-pressure surface corner, whereas it increases aerodynamic loss in the central area of the passage vortex region. The additional leading-edge winglet portion of the LEPS winglet reduces aerodynamic loss considerably on the casing wall side of the passage vortex region but delivers a noticeable aerodynamic loss increase on its mid-span side. These local trends are deepened with increasing w/p. However, the mass-averaged aerodynamic loss reductions by installing the PS and LEPS winglets in comparison with the baseline no winglet data are only marginal even for w/p = 10.55% and found much smaller than that by employing a cavity squealer tip.

  7. Research progress in TIPS shunt dysfunction and recanalization

    Directory of Open Access Journals (Sweden)

    WANG Tingting

    2015-11-01

    Full Text Available Transjugular intrahepatic portosystemic shunt (TIPS is widely used in the treatment of cirrhotic portal hypertension and its associated complications. However, postoperative shunt dysfunction has been an important factor restricting the clinical application of TIPS. This article summarizes the use of shunt, the incidence of shunt dysfunction after TIPS, preventive measures and diagnostic methods for shunt dysfunction, and indications and techniques of shunt recanalization, in order to enhance our knowledge of shunt dysfunction and recanalization, which could further improve the efficacy of TIPS for cirrhotic portal hypertension.

  8. Excised radicle tips as a source of genomic DNA for PCR-based ...

    Indian Academy of Sciences (India)

    2012-12-13

    Dec 13, 2012 ... Cotton; cry1Ac; genomic DNA isolation; high-resolution melting curve analysis; radicle tip; seed purity testing .... cooled to 40°C. Fluorescence data for melting curves were ... greatly increased by introducing automation.

  9. Twelve Tips for Effective Electronic Presentation.

    Science.gov (United States)

    Crosby, Joy

    1994-01-01

    Offers 12 tips for effective electronic presentation. This article is intended for readers who may be considering using electronic presentation for the first time. Offers reasons for its popularity and occasions when it may be used. The tips offer assistance in the design and presentation of electronic material. (LZ)

  10. Low Vision Tips

    Science.gov (United States)

    ... this page: https://medlineplus.gov/lowvision.html MedlinePlus: Low Vision Tips We are sorry. MedlinePlus no longer maintains the For Low Vision Users page. You will still find health resources ...

  11. Observations on Hydride Structures at the Tip of Arrested Cracks Grown under Conditions of Delayed Hydride Cracking

    International Nuclear Information System (INIS)

    Pettersson, Kjell; Oskarsson, Magnus; Bergqvist, Hans

    2003-04-01

    One sample of Zr2.5%Nb and one sample of cold worked and stress relieved Zircaloy-4 which have been tested for hydrogen induced crack growth have been examined in the crack tip region with the aim of determining the mechanism behind the growth of cracks. The proposed mechanisms are brittle failure of a crack tip hydride and hydrogen enhanced localized shear. The examinations were done by TEM and SEM. However attempts to produce a TEM specimen with a thinned region at the tip of the crack were unsuccessful in both samples. One feature observed in the Zr2.5%Nb material may however be an indication of intense shear deformation at the tip of the crack. On the other hand all observations on the Zircaloy-4 sample indicate precipitation of hydrides ahead of the crack tip and the presence of hydrides on the crack flanks

  12. Tips for Reducing Pesticide Impacts on Wildlife

    Science.gov (United States)

    This Web page provides tips for pesticide users in residential and agricultural settings, as well as tips for certified pesticide applicators for ways to protect wildlife from potentially harmful effects of pesticides.

  13. Short communication: QTL mapping for ear tip-barrenness in maize

    Energy Technology Data Exchange (ETDEWEB)

    Ding, J.; Ma, J.; Chen, J.; Ai, T.; Li, Z.; Tian, Z.; Wu, S.; Chen, W.; Wu, J.

    2016-11-01

    Barren tip on corn ear is an important agronomic trait in maize, which is highly associated with grain yield. Understanding the genetic basis of tip-barrenness may help to reduce the ear tip-barrenness in breeding programs. In this study, ear tip-barrenness was evaluated in two environments in a F2:3 population, and it showed significant genotypic variation for ear tip-barrenness in both environments. Using mixed-model composite interval mapping method, three additive effects quantitative trait loci (QTL) for ear tip-barrenness were mapped on chromosomes 2, 3 and 6, respectively. They explained 16.6% of the phenotypic variation, and no significant QTL × Environment interactions and digenic interactions were detected. The results indicated that additive effect was the main genetic basis for ear tip-barrenness in maize. This is the first report of QTL mapped for ear tip-barrenness in maize. (Author)

  14. Invited Review Article: Tip modification methods for tip-enhanced Raman spectroscopy (TERS) and colloidal probe technique: A 10 year update (2006-2016) review

    Science.gov (United States)

    Yuan, C. C.; Zhang, D.; Gan, Y.

    2017-03-01

    Engineering atomic force microscopy tips for reliable tip enhanced Raman spectroscopy (TERS) and colloidal probe technique are becoming routine practices in many labs. In this 10 year update review, various new tip modification methods developed over the past decade are briefly reviewed to help researchers select the appropriate method. The perspective is put in a large context to discuss the opportunities and challenges in this area, including novel combinations of seemingly different methods, potential applications of some methods which were not originally intended for TERS tip fabrication, and the problems of high cost and poor reproducibility of tip fabrication.

  15. Dependence of electric field on STM tip preparation

    DEFF Research Database (Denmark)

    Huang, D.H.; Grey, Francois; Aono, M.

    1998-01-01

    Voltage pulses applied between an STM tip and a surface can modify the surface on the nanometer scale due to electric-field-induced evaporation. However, at present, different groups have achieved surface modification with quite different bias conditions, and it is still difficult to obtain high...... reproducibility in such experiments. In this paper, we measure the tip displacement during a pulse at constant tunnelling current, and deduce that the electric field produced by the pulse depends in a systematic way on tip preparation, The results show how differences in tip preparation can be a major source...

  16. Relocalization of human chromatin remodeling cofactor TIP48 in mitosis

    International Nuclear Information System (INIS)

    Sigala, Barbara; Edwards, Mina; Puri, Teena; Tsaneva, Irina R.

    2005-01-01

    TIP48 is a highly conserved eukaryotic AAA + protein which is an essential cofactor for several complexes involved in chromatin acetylation and remodeling, transcriptional and developmental regulation and nucleolar organization and trafficking. We show that TIP48 abundance in HeLa cells did not change during the cell cycle, nor did its distribution in various biochemical fractions. However, we observed distinct changes in the subcellular localization of TIP48 during M phase using immunofluorescence microscopy. Our studies demonstrate that in interphase cells TIP48 was found mainly in the nucleus and exhibited a distinct localization in the nuclear periphery. As the cells entered mitosis, TIP48 was excluded from the condensing chromosomes but showed association with the mitotic apparatus. During anaphase, some TIP48 was detected in the centrosome colocalizing with tubulin but the strongest staining appeared in the mitotic equator associated with the midzone central spindle. Accumulation of TIP48 in the midzone and the midbody was observed in late telophase and cytokinesis. This redeployment of TIP48 during anaphase and cytokinesis was independent of microtubule assembly. The relocation of endogenous TIP48 to the midzone/midbody under physiological conditions suggests a novel and distinct function for TIP48 in mitosis and possible involvement in the exit of mitosis

  17. Angle-tip Fiber Probe as Humidity Sensor

    Directory of Open Access Journals (Sweden)

    Pabitra NATH

    2010-05-01

    Full Text Available In this paper, I present a simple fiber optic relative humidity sensor (FORHS using an angled-tip multimode optical fiber. The sensing region is fabricated by coating moisture sensitive Cobalt Chloride (CoCl2 doped polyvinyl alcohol (PVA film on the surface of fiber optic tip. Light signal introducing from flat-end of the fiber is back-reflected at the fiber tip-air interface by the effect of total internal refection. The change of relative humidity (RH in the outstanding medium affects of evanescent field absorption at the fiber tip-sensing film interface thus, modulates the back-reflected signal. With the present sensing investigation, RH ranging from 5 % to 95 % can be measured with high degree of repeatability and has a fast response time of about 2 seconds.

  18. Expression Analysis of cPLA2 Alpha Interacting TIP60 in Diabetic KKAy and Non-Diabetic C57BL Wild-Type Mice: No Impact of Transient and Stable TIP60 Overexpression on Glucose-Stimulated Insulin Secretion in Pancreatic Beta-Cells

    DEFF Research Database (Denmark)

    Nordentoft, Iver Kristiansen; Jeppesen, Per Bendix; Nielsen, Anders Lade

    2007-01-01

    In the present study we investigate the expression levels of cytosolic phospholipase A2 alpha (cPLA2alpha) interacting histone acetyl transferase proteins TIP60alpha and TIP60beta in non-diabetic C57BL wild-type mice and obese type 2 diabetic KKAy model mice. The aim was to test our hypothesis...

  19. Investigation of the Shear Flow Effect and Tip Clearance on a Low Speed Axial Flow Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Mahesh Varpe

    2013-01-01

    Full Text Available This paper explores the effect of inlet shear flow on the tip leakage flow in an axial flow compressor cascade. A flow with a high shear rate is generated in the test section of an open circuit cascade wind tunnel by using a combination of screens with a prescribed solidity. It is observed that a stable shear flow of shear rate 1.33 is possible and has a gradual decay rate until 15 times the height of the shear flow generator downstream. The computational results obtained agree well with the available experimental data on the baseline configuration. The detailed numerical analysis shows that the tip clearance improves the blade loading near the tip through the promotion of favorable incidence by the tip leakage flow. The tip clearance shifts the centre of pressure on the blade surface towards the tip. It, however, has no effect on the distribution of end wall loss and deviation angle along the span up to 60% from the hub. In the presence of a shear inflow, the end wall effects are considerable. On the other hand, with a shear inflow, the effects of tip leakage flow are observed to be partly suppressed. The shear flow reduces the tip leakage losses substantially in terms of kinetic energy associated with it.

  20. KNOW-BLADE, task-3.2 report, tip shape study

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, N.N.; Johansen, J.; Conway, S.; Voutsinas, S.; Hansen, M.O.L.; Stuermer, A.

    2005-01-01

    For modern rotor blades with their very large aspect ratio, the blade tip is a very limited part of the overall rotor, and as such of limited importance for the overall aerodynamics of the rotor. Even though they may not be very important for the overall power production, the tip noise can be very important for the acoustics of the rotor [15], and the blade tips can as well be important for the aerodynamic damping properties of the rotor blades [13]. Unfortunately, not many options exists for predicting the aerodynamic behavior of blade tips using computational methods. Experimentally it is dicult to perform detailed measurements in the form of pressure and velocity measurements in natural wind conditions on modern large scale turbines due to the inherent unsteadiness in the natural wind. The present study describes the application of four different Navier-Stokes solvers to tip shape studies, and shows that these codes are well suited to study the flow around different tip shape geometries, and can predict the pressure distributions at the blade tip quite accurately. (au)

  1. The Tipping Points of Technology Development

    Directory of Open Access Journals (Sweden)

    Tauno Kekäle

    2014-07-01

    Full Text Available The tipping point, the decisive point in time in the competition between old and new, is an interesting phenomenon in physics of today. This aspect in technology acceptance is connected to many business decisions such as technology investments, product releases, resource allocation, sales forecasts and, ultimately, affects the profitability and even survival of a company. The tipping point itself is based on many stochastic and dynamic variables, and the process may at least partly be described as path-dependent. This paper analyses the tipping point from three aspects: (1 product performance, (2 features of the market and infrastructure (including related technologies and human network externalities, and (3 actions of the incumbents (including customer lock-in, systems lock-in, and sustaining innovation. The paper is based on the Bass s-curve idea and the technology trajectory concept proposed by Dosi. Three illustrative cases are presented to make the point of the multiple factors affecting technology acceptance and, thus, the tipping point. The paper also suggests outlines for further research in field of computer simulation.

  2. Final Technical Report: Electrohydrodynamic Tip Streaming

    Energy Technology Data Exchange (ETDEWEB)

    Basaran, Osman [Purdue Univ., West Lafayette, IN (United States)

    2016-01-06

    When subjected to strong electric fields, liquid drops and films form conical tips and emit thin jets from their tips. Such electrodydrodynamic (EDH) tip streaming or cone-jetting phenomena, which are sometimes referred to as electrospraying, occur widely in nature, e.g., in ejection of streams of small charged drops from pointed tips of raindrops in thunderclouds, and technology, e.g., in electrospray mass spectrometry or electric field-driven solvent extraction. More recently, EHD cone-jetting has emerged as a powerful technique for direct printing of solar cells, micro- and nano- particle production, and microencapsulation for controlled release. In many of the aforementioned situations, of equal importance to the processes by which one drop disintegrates to form several drops are those by which (a) two drops come together and coalesce and (b) two drops are coupled to form a double droplet system (DDS) or a capillary switch (CS). the main objective of this research program is to advance through simulation, theory, and experiment the breakup, coalescence, and oscillatory dynamics of single and pairs of charged as well as uncharged drops.

  3. Diabetes: Dental Tips

    Science.gov (United States)

    Diabetes: Dental Tips For more copies contact: National Institute of Dental and Craniofacial Research National Oral Health Information Clearinghouse ... damage the gum and bone that hold your teeth in place and may lead to painful chewing ...

  4. TEM observations of crack tip: cavity interactions

    International Nuclear Information System (INIS)

    Horton, J.A.; Ohr, S.M.; Jesser, W.A.

    1981-01-01

    Crack tip-cavity interactions have been studied by performing room temperature deformation experiments in a transmission electron microscope on ion-irradiated type 316 stainless steel with small helium containing cavities. Slip dislocations emitted from a crack tip cut, sheared, and thereby elongated cavities without a volume enlargement. As the crack tip approached, a cavity volume enlargement occurred. Instead of the cavities continuing to enlarge until they touch, the walls between the cavities fractured. Fracture surface dimples do not correlate in size or density with these enlarged cavities

  5. Root tips moving through soil

    Science.gov (United States)

    Curlango-Rivera, Gilberto

    2011-01-01

    Root elongation occurs by the generation of new cells from meristematic tissue within the apical 1–2 mm region of root tips. Therefore penetration of the soil environment is carried out by newly synthesized plant tissue, whose cells are inherently vulnerable to invasion by pathogens. This conundrum, on its face, would seem to reflect an intolerable risk to the successful establishment of root systems needed for plant life. Yet root tip regions housing the meristematic tissues repeatedly have been found to be free of microbial infection and colonization. Even when spore germination, chemotaxis, and/or growth of pathogens are stimulated by signals from the root tip, the underlying root tissue can escape invasion. Recent insights into the functions of root border cells, and the regulation of their production by transient exposure to external signals, may shed light on long-standing observations. PMID:21455030

  6. Regulation of Histone Acetyltransferase TIP60 Function by Histone Deacetylase 3

    Science.gov (United States)

    Yi, Jingjie; Huang, Xiangyang; Yang, Yuxia; Zhu, Wei-Guo; Gu, Wei; Luo, Jianyuan

    2014-01-01

    The key member of the MOZ (monocyticleukaemia zinc finger protein), Ybf2/Sas3, Sas2, and TIP60 acetyltransferases family, Tat-interactive protein, 60 kD (TIP60), tightly modulates a wide array of cellular processes, including chromatin remodeling, gene transcription, apoptosis, DNA repair, and cell cycle arrest. The function of TIP60 can be regulated by SIRT1 through deacetylation. Here we found that TIP60 can also be functionally regulated by HDAC3. We identified six lysine residues as its autoacetylation sites. Mutagenesis of these lysines to arginines completely abolishes the autoacetylation of TIP60. Overexpression of HDAC3 increases TIP60 ubiquitination levels. However, unlike SIRT1, HDAC3 increased the half-life of TIP60. Further study found that HDAC3 colocalized with TIP60 both in the nucleus and the cytoplasm, which could be the reason why HDAC3 can stabilize TIP60. The deacetylation of TIP60 by both SIRT1 and HDAC3 reduces apoptosis induced by DNA damage. Knockdown of HDAC3 in cells increased TIP60 acetylation levels and increased apoptosis after DNA damage. Together, our findings provide a better understanding of TIP60 regulation mechanisms, which is a significant basis for further studies of its cellular functions. PMID:25301942

  7. TIPS - anastomose portossistêmica intra-hepática transjugular. Revisão TIPS - transjugular intrahepatic portosystemic shunt. A review

    Directory of Open Access Journals (Sweden)

    Gerson CARREIRO

    2001-01-01

    Full Text Available Diversas alternativas terapêuticas têm sido usadas, atualmente, na tentativa de reduzir a mortalidade de pacientes com hipertensão portal que desenvolvem varizes esofagianas. Abordagem de uma dessas alternativas que ainda é de exceção e pouco utilizada em nosso meio - o "shunt" (desvio portossistêmico intra-hepático transjugular - TIPS ("transjugular intrahepatic portasystemic shunt". O TIPS possibilita redução significativa do gradiente de pressão portohepático, uma vez que funciona como um "shunt" portocava látero-lateral, promovendo, dessa forma, descompressão eficiente do sistema portal, reduzindo significativamente o risco de sangramentos. A técnica consiste na inserção percutânea, através da veia jugular interna, de malha metálica através do parênquima hepático, sob controle angiográfico, criando verdadeira comunicação portocava. Bons resultados na utilização do TIPS têm sido atestados em diversos estudos, muito embora bem poucos deles tenham sido controlados e randomizados de modo a concluir que esse procedimento é seguro, eficaz e com boa relação custo-benefício. Dessa forma, buscou-se, nesta revisão, uma análise do estado atual da utilização do TIPS, sua técnica, principais indicações e complicações. O TIPS vem sendo utilizado nos casos de hemorragia digestiva refratária ao tratamento farmacológico e/ou endoscópico, principalmente em pacientes Child-Pugh B e C ou ainda como opção de controle do quadro, servindo como "ponte" para um futuro transplante hepático. Pode-se considerar ainda o tratamento da ascite refratária, da síndrome hepatorrenal e do hidrotórax hepático como promissoras indicações definitivas para a colocação do TIPS. As complicações dessa técnica estão relacionadas, sobretudo, a sua colocação, às conseqüências hemodinâmicas imediatas, como a encefalopatia hepática, e às complicações tardias envolvendo principalmente a oclusão do "stent" (prótese auto

  8. Mind the gap - tip leakage vortex in axial turbines

    International Nuclear Information System (INIS)

    Dreyer, M; Farhat, M; Decaix, J; Münch-Alligné, C

    2014-01-01

    The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex

  9. Mind the gap - tip leakage vortex in axial turbines

    Science.gov (United States)

    Dreyer, M.; Decaix, J.; Münch-Alligné, C.; Farhat, M.

    2014-03-01

    The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex.

  10. AFM tip characterization by using FFT filtered images of step structures

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yongda, E-mail: yanyongda@hit.edu.cn [Key Laboratory of Micro-systems and Micro-structures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin, Heilongjiang 150001 (China); Center For Precision Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001 (China); Xue, Bo [Key Laboratory of Micro-systems and Micro-structures Manufacturing of Ministry of Education, Harbin Institute of Technology, Harbin, Heilongjiang 150001 (China); Center For Precision Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001 (China); Hu, Zhenjiang; Zhao, Xuesen [Center For Precision Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001 (China)

    2016-01-15

    The measurement resolution of an atomic force microscope (AFM) is largely dependent on the radius of the tip. Meanwhile, when using AFM to study nanoscale surface properties, the value of the tip radius is needed in calculations. As such, estimation of the tip radius is important for analyzing results taken using an AFM. In this study, a geometrical model created by scanning a step structure with an AFM tip was developed. The tip was assumed to have a hemispherical cone shape. Profiles simulated by tips with different scanning radii were calculated by fast Fourier transform (FFT). By analyzing the influence of tip radius variation on the spectra of simulated profiles, it was found that low-frequency harmonics were more susceptible, and that the relationship between the tip radius and the low-frequency harmonic amplitude of the step structure varied monotonically. Based on this regularity, we developed a new method to characterize the radius of the hemispherical tip. The tip radii estimated with this approach were comparable to the results obtained using scanning electron microscope imaging and blind reconstruction methods. - Highlights: • The AFM tips with different radii were simulated to scan a nano-step structure. • The spectra of the simulation scans under different radii were analyzed. • The functions of tip radius and harmonic amplitude were used for evaluating tip. • The proposed method has been validated by SEM imaging and blind reconstruction.

  11. Blade tip, finite aspect ratio, and dynamic stall effects on the Darrieus rotor

    Science.gov (United States)

    Paraschivoiu, I.; Desy, P.; Masson, C.

    1988-02-01

    The objective of the work described in this paper was to apply the Boeing-Vertol dynamic stall model in an asymmetric manner to account for the asymmetry of the flow between the left and right sides of the rotor. This phenomenon has been observed by the flow visualization of a two-straight-bladed Darrieus rotor in the IMST water tunnel. Also introduced into the aerodynamic model are the effects of the blade tip and finite aspect ratio on the aerodynamic performance of the Darrieus wind turbine. These improvements are compatible with the double-multiple-streamtube model and have been included in the CARDAAV computer code for predicting the aerodynamic performance. Very good agreement has been observed between the test data (Sandia 17 m) and theoretical predictions; a significant improvement over the previous dynamic stall model was obtained for the rotor power at low tip speed ratios, while the inclusion of the finite aspect ratio effects enhances the prediction of the rotor power for high tip speed ratios. The tip losses and finite aspect ratio effects were also calculated for a small-scale vertical-axis wind turbine, with a two-straight-bladed (NACA 0015) rotor.

  12. A Comparative Study of Conventional and Tip-Fin Propeller Performance

    DEFF Research Database (Denmark)

    Andersen, Poul

    1997-01-01

    During more than a decade several attempts have been made to obtain higher propeller efficiencies by radically modifying the geometry in the tip region of the blade. In the tip-fin propeller a tip fin or winglet is attached to the blade tip and integrated into the blade in such a way that the bla...

  13. Structure and stability of semiconductor tip apexes for atomic force microscopy

    International Nuclear Information System (INIS)

    Pou, P; Perez, R; Ghasemi, S A; Goedecker, S; Jelinek, P; Lenosky, T

    2009-01-01

    The short range force between the tip and the surface atoms, that is responsible for atomic-scale contrast in atomic force microscopy (AFM), is mainly controlled by the tip apex. Thus, the ability to image, manipulate and chemically identify single atoms in semiconductor surfaces is ultimately determined by the apex structure and its composition. Here we present a detailed and systematic study of the most common structures that can be expected at the apex of the Si tips used in experiments. We tackle the determination of the structure and stability of Si tips with three different approaches: (i) first principles simulations of small tip apexes; (ii) simulated annealing of a Si cluster; and (iii) a minima hopping study of large Si tips. We have probed the tip apexes by making atomic contacts between the tips and then compared force-distance curves with the experimental short range forces obtained with dynamic force spectroscopy. The main conclusion is that although there are multiple stable solutions for the atomically sharp tip apexes, they can be grouped into a few types with characteristic atomic structures and properties. We also show that the structure of the last atomic layers in a tip apex can be both crystalline and amorphous. We corroborate that the atomically sharp tips are thermodynamically stable and that the tip-surface interaction helps to produce the atomic protrusion needed to get atomic resolution.

  14. Pre-Liver Transplant: Tips Versus Distal Splenorenal Shunt

    Directory of Open Access Journals (Sweden)

    Thomas W. Faust

    1997-01-01

    Full Text Available Recurrent variceal bleeding in liver transplant candidates with end-stage liver disease can complicate or even prohibit a subsequent transplant procedure (OLT. Endoscopic sclero-therapy and medical therapy are considered as first-line management with surgical shunts reserved for refractory situations. Surgical shunts can be associated with a high mortality in this population and may complicate subsequent OLT. The transjugular intrahepatic portosystemic shunt (TIPS has been recommended in these patients as a bridge to OLT. This is a new modality that has not been compared with previously established therapies such as the distal splenorenal shunt (DSRS. In this study we report our experience with 35 liver transplant recipients who had a previous TIPS (18 patients or DSRS (17 patients for variceal bleeding. The TIPS group had a significantly larger proportion of critically ill and Child-Pugh C patients. Mean operating time was more prolonged in the DSRS group (P=0.014 but transfusion requirements were similar. Intraoperative portal vein blood flow measurements averaged 2132±725 ml/min in the TIPS group compared with 1120±351ml/min in the DSRS group (P<0.001. Arterial flows were similar. Mean ICU and hospital stays were similar. There were 3 hospital mortalities in the DSRS group and none in the TIPS group (P=0.1. We conclude that TIPS is a valuable tool in the management of recurrent variceal bleeding prior to liver transplantation. Intra0Perative hemodynamic measurements suggest a theoretical advantage with TIPS. In a group of patients with advanced liver disease we report an outcome that is similar to patients treated with DSRS prior to liver transplantation. The role of TIPS in the treatment of nontransplant candidates remains to be clarified.

  15. Improvement of Transdermal Delivery of Exendin-4 Using Novel Tip-Loaded Microneedle Arrays Fabricated from Hyaluronic Acid.

    Science.gov (United States)

    Liu, Shu; Wu, Dan; Quan, Ying-Shu; Kamiyama, Fumio; Kusamori, Kosuke; Katsumi, Hidemasa; Sakane, Toshiyasu; Yamamoto, Akira

    2016-01-04

    The purpose of this study was to evaluate the characteristics of exendin-4 tip-loaded microneedle arrays and to compare their acute efficacy with subcutaneous injections in type 2 diabetic GK/Slc rats. Fluorescein isothiocyanate labeled dextran with an average molecular weight of 4,000 (FD4) was selected as a model drug, and FD4 tip-loaded microneedle arrays were prepared in this study. In addition, intraperitoneal glucose tolerance tests after application of exendin-4 tip-loaded microneedle arrays were also compared with those after subcutaneous injection in type 2 diabetic GK/Slc rats. The release of FD4 from the tip-loaded microneedle arrays was very rapid, particularly in the initial 30 s, and most of the FD4 was released within 5 min. In addition, glucose tolerance was improved and the insulin secretion was enhanced after application of exendin-4 tip-loaded microneedle arrays, and these effects were comparable to those after subcutaneous injection of exendin-4. Similar plasma concentration profiles were seen after application of exendin-4 tip-loaded microneedle arrays, as was the case with subcutaneous injection in type 2 diabetic GK/Slc rats. These findings indicate that exendin-4 tip-loaded microneedle arrays can be used as an alternative to achieve sufficient delivery of exendin-4 for treatment of type 2 diabetes. To our knowledge, this is the first report of transdermal exendin-4 delivery using tip-loaded microneedle arrays.

  16. In situ scanning tunneling microscope tip treatment device for spin polarization imaging

    Science.gov (United States)

    Li, An-Ping [Oak Ridge, TN; Jianxing, Ma [Oak Ridge, TN; Shen, Jian [Knoxville, TN

    2008-04-22

    A tip treatment device for use in an ultrahigh vacuum in situ scanning tunneling microscope (STM). The device provides spin polarization functionality to new or existing variable temperature STM systems. The tip treatment device readily converts a conventional STM to a spin-polarized tip, and thereby converts a standard STM system into a spin-polarized STM system. The tip treatment device also has functions of tip cleaning and tip flashing a STM tip to high temperature (>2000.degree. C.) in an extremely localized fashion. Tip coating functions can also be carried out, providing the tip sharp end with monolayers of coating materials including magnetic films. The device is also fully compatible with ultrahigh vacuum sample transfer setups.

  17. Acoustic measurements of a full-scale rotor with four tip shapes. Volume 1: Text, appendices A and B

    Science.gov (United States)

    Mosher, M.

    1984-01-01

    A full-scale helicopter with four different blade-tip geometries was tested in the 40- by 80-foot wind tunnel at Ames Research Center. Performance, loads, and noise were measured. The four tip shapes tested were rectangular, tapered, swept, and swept-tapered. Noise measurements from that test are presented in the form of tables and plots. The noise data include measurements of the sound pressure level in dB, dBA, and tone-corrected PNdB, for all of the conditions tested. Detailed measurements, 1/3-octave spectra and time-histories for some selected data are included as well as plots of dBA as function of test condition. Some performance measurements are given to aid interpretation of the noise data.

  18. Lattice dynamical and thermodynamical properties of ReB2, RuB2, and OsB2 compounds in the ReB2 structure

    International Nuclear Information System (INIS)

    Deligoz, E.; Colakoglu, K.; Ciftci, Y. O.

    2012-01-01

    Structural and lattice dynamical properties of ReB 2 , RuB 2 , and OsB 2 in the ReB 2 structure are studied in the framework of density functional theory within the generalized gradient approximation. The present results show that these compounds are dynamically stable for the considered structure. The temperature-dependent behaviors of thermodynamical properties such as internal energy, free energy, entropy, and heat capacity are also presented. The obtained results are in good agreement with the available experimental and theoretical data

  19. Flouroscopically–guided transhepatic puncture for difficult TIPS re-do procedures utilizing the En Snare retrieval device: A new approach to occluded TIPS in patients with recurrent ascites

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Berlet, Matthew H.

    2012-01-01

    Portal hypertension and variceal bleeding are complications due to cirrhosis. Transjugular Intraphepatic Portosystemic shunt (TIPS) procedure is a well-established treatment for recurrent ascites and variceal bleeding related to portal hypertension. After a TIPS has been placed, the potential of TIPS occlusion or stenosis is high. A TIPS re-do procedure has been used in treatment of progressive clinical symptoms. The standard approach is via the jugular route to recannulate the TIPS shunt. Rarely, it cannot be performed from the jugular approach. Therefore, a fluoroscopically -guided transhepatic approach has been devised for these difficult situations. This case describes the use of the transhepatic route through an indwelling Viatorr covered stent utilizing an En-Snare device to help complete the TIPS re-do procedure. With this newer approach to TIPS re-do procedures, endovascular specialists can achieve TIPS patency despite difficult venous anatomical challenges and the various types of available TIPS stents presently on the market.

  20. Crack Tip Mechanics in Distortion Gradient Plasticity

    DEFF Research Database (Denmark)

    Fuentes-Alonso, Sandra; Martínez Pañeda, Emilio

    2017-01-01

    Gradient Plasticity (DGP), the influence on crack tip mechanics of DGP's distinguishing features that entail superior modelling capabilities has not been investigated yet. In this work crack tip fields are thoroughly examined by implementing the higher order theory of DGP in an implicit finite element...

  1. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  2. Centrifugal compressor tip clearance and impeller flow

    International Nuclear Information System (INIS)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari; Engeda, Abraham

    2016-01-01

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease

  3. Local measurement and numerical modeling of mass/heat transfer from a turbine blade in a linear cascade with tip clearance

    Science.gov (United States)

    Jin, Peitong

    2000-11-01

    Local mass/heat transfer measurements from the turbine blade near-tip and the tip surfaces are performed using the naphthalene sublimation technique. The experiments are conducted in a linear cascade consisting of five high-pressure blades with a central test-blade configuration. The incoming flow conditions are close to those of the gas turbine engine environment (boundary layer displacement thickness is about 0.01 of chord) with an exit Reynolds number of 6.2 x 105. The effects of tip clearance level (0.86%--6.90% of chord), mainstream Reynolds number and turbulence intensity (0.2 and 12.0%) are investigated. Two methods of flow visualization---oil and lampblack, laser light sheet smoke wire---as well as static pressure measurement on the blade surface are used to study the tip leakage flow and vortex in the cascade. In addition, numerical modeling of the flow and heat transfer processes in the linear cascade with different tip clearances is conducted using commercial software incorporating advanced turbulence models. The present study confirms many important results on the tip leakage flow and vortex from the literature, contributes to the current understanding in the effects of tip leakage flow and vortex on local heat transfer from the blade near-tip and the tip surfaces, and provides detailed local and average heat/mass transfer data applicable to turbine blade tip cooling design.

  4. Liquid Oxygen Rotating Friction Ignition Testing of Aluminum and Titanium with Monel and Inconel for Rocket Engine Propulsion System Contamination Investigation

    Science.gov (United States)

    Peralta, S.; Rosales, Keisa R.; Stoltzfus, Joel M.

    2009-01-01

    Metallic contaminant was found in the liquid oxygen (LOX) pre-valve screen of the shuttle main engine propulsion system on two orbiter vehicles. To investigate the potential for an ignition, NASA Johnson Space Center White Sands Test Facility performed (modified) rotating friction ignition testing in LOX. This testing simulated a contaminant particle in the low-pressure oxygen turbo pump (LPOTP) and the high-pressure oxygen turbo pump (HPOTP) of the shuttle main propulsion system. Monel(R) K-500 and Inconel(R) 718 samples represented the LPOTP and HPOTP materials. Aluminum foil tape and titanium foil represented the contaminant particles. In both the Monel(R) and Inconel(R) material configurations, the aluminum foil tape samples did not ignite after 30 s of rubbing. In contrast, all of the titanium foil samples ignited regardless of the rubbing duration or material configuration. However, the titanium foil ignitions did not propagate to the Monel and Inconel materials.

  5. Identification and functional analysis of endothelial tip cell-enriched genes.

    Science.gov (United States)

    del Toro, Raquel; Prahst, Claudia; Mathivet, Thomas; Siegfried, Geraldine; Kaminker, Joshua S; Larrivee, Bruno; Breant, Christiane; Duarte, Antonio; Takakura, Nobuyuki; Fukamizu, Akiyoshi; Penninger, Josef; Eichmann, Anne

    2010-11-11

    Sprouting of developing blood vessels is mediated by specialized motile endothelial cells localized at the tips of growing capillaries. Following behind the tip cells, endothelial stalk cells form the capillary lumen and proliferate. Expression of the Notch ligand Delta-like-4 (Dll4) in tip cells suppresses tip cell fate in neighboring stalk cells via Notch signaling. In DLL4(+/-) mouse mutants, most retinal endothelial cells display morphologic features of tip cells. We hypothesized that these mouse mutants could be used to isolate tip cells and so to determine their genetic repertoire. Using transcriptome analysis of retinal endothelial cells isolated from DLL4(+/-) and wild-type mice, we identified 3 clusters of tip cell-enriched genes, encoding extracellular matrix degrading enzymes, basement membrane components, and secreted molecules. Secreted molecules endothelial-specific molecule 1, angiopoietin 2, and apelin bind to cognate receptors on endothelial stalk cells. Knockout mice and zebrafish morpholino knockdown of apelin showed delayed angiogenesis and reduced proliferation of stalk cells expressing the apelin receptor APJ. Thus, tip cells may regulate angiogenesis via matrix remodeling, production of basement membrane, and release of secreted molecules, some of which regulate stalk cell behavior.

  6. The Ultrachopper tip: a wound temperature study.

    Science.gov (United States)

    Barlow, William R; Pettey, Jeff; Olson, Randall J

    2013-12-01

    To determine the thermal characteristics of the Ultrachopper and its thermal properties in varied viscosurgical substances. Experimental study. Not applicable. The Ultrachopper (Alcon, Inc) tip with the Infiniti (Alcon, Inc) handpiece was attached to a thermistor and placed in a test chamber filled with either an ophthalmic viscosurgical device (OVD) or balanced salt solution (BSS). The thermistor allowed for continuous monitoring of temperature from baseline and the change that occurred over 60 seconds of continuous run time. Mean maximum temperature in each OVD exceeded 50°C over the first 25 seconds of continuous run time. The mean maximum temperature was statistically significantly higher with all OVDs (p < 0.0001) when compared with BSS. A small but statistically significant difference in mean maximum temperature was shown between Healon 5 (AMO, Inc) and Viscoat (Alcon, Inc) (p < 0.05). The linear increase in temperature was statistically significantly different with all OVDs compared with BSS (p < 0.0001). The thermal properties of the Ultrachopper tip demonstrate a heat-generating capacity that achieves published thresholds for risk for wound burn. Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  7. Pulsed growth of fungal hyphal tips.

    Science.gov (United States)

    López-Franco, R; Bartnicki-Garcia, S; Bracker, C E

    1994-12-06

    Somatic fungal hyphae are generally assumed to elongate at steady linear rates when grown under constant environmental conditions with ample nutrients. However, patterns of pulsed hyphal elongation were detected during apparent steady growth of hyphal tips in fungi from several major taxonomic groups (Oomycetes, Pythium aphanidermatum and Saprolegnia ferax; Zygomycetes, Gilbertella persicaria; Deuteromycetes, Trichoderma viride; Ascomycetes, Neurospora crassa and Fusarium culmorum; Basidiomycetes, Rhizoctonia solani). Growing hyphal tips were recorded with video-enhanced phase-contrast microscopy at high magnification, and digital images were measured at very short time intervals (1-5 s). In all fungi tested, the hyphal elongation rate was never perfectly steady but fluctuated continuously with alternating periods of fast and slow growth at more or less regular intervals. Pulsed growth was observed in fungi differing in cell diameter, overall growth rate, taxonomic position, and presence and pattern of Spitzenkörper organization, suggesting that this is a general phenomenon. Frequency and amplitude of the pulses varied among the test organisms. T. viride and N. crassa showed the most frequent pulses (average of 13-14 per min), and F. culmorum the least frequent (2.7 per min). Average pulse amplitude varied from 0.012 microns/s for F. culmorum to 0.068 microns/s for G. persicaria. In F. culmorum and T. viride, the fast phase of the growth pulses was correlated with the merger of satellite Spitzenkörper with the main Spitzenkörper. These findings are consistent with a causal relationship between fluctuations in the overall rate of secretory vesicle delivery/discharge at the hyphal apex and the fluctuations in hyphal elongation rate.

  8. Ablation characteristics of boding liver according to cool-tip temperature of RFA equipment

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Jae [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Jeong Koo [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of)

    2015-06-15

    This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with 4 x 4 x 4 cm{sup 3} in 2 cm cool-tip and with 6 x 6 x 6 cm{sup 3} in 3 cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2 cm and 3 cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown (p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant (p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.

  9. Ablation characteristics of boding liver according to cool-tip temperature of RFA equipment

    International Nuclear Information System (INIS)

    Choi, Young Jae; Kim, Jeong Koo

    2015-01-01

    This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with 4 x 4 x 4 cm"3 in 2 cm cool-tip and with 6 x 6 x 6 cm"3 in 3 cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2 cm and 3 cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown (p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant (p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately

  10. Modular design of AFM probe with sputtered silicon tip

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Thaysen, Jacob; Bouwstra, Siebe

    2001-01-01

    of the thin films constituting the cantilever. The AFM probe has an integrated tip made of a thick sputtered silicon layer, which is deposited after the probe has been defined and just before the cantilevers are released. The tips are so-called rocket tips made by reactive ion etching. We present probes...

  11. 21 CFR 880.6025 - Absorbent tipped applicator.

    Science.gov (United States)

    2010-04-01

    ... stick. The device is used to apply medications to, or to take specimens from, a patient. (b...) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Miscellaneous Devices § 880.6025 Absorbent tipped applicator. (a) Identification. An absorbent tipped applicator is a...

  12. Some observations of tip-vortex cavitation

    Science.gov (United States)

    Arndt, R. E. A.; Arakeri, V. H.; Higuchi, H.

    1991-08-01

    Cavitation has been observed in the trailing vortex system of an elliptic platform hydrofoil. A complex dependence on Reynolds number and gas content is noted at inception. Some of the observations can be related to tension effects associated with the lack of sufficiently large-sized nuclei. Inception measurements are compared with estimates of pressure in the vortex obtained from LDV measurements of velocity within the vortex. It is concluded that a complete correlation is not possible without knowledge of the fluctuating levels of pressure in tip-vortex flows. When cavitation is fully developed, the observed tip-vortex trajectory flows. When cavitation is fully developed, the observed tip-vortex trajectory shows a surprising lack of dependence on any of the physical parameters varied, such as angle of attack, Reynolds number, cavitation number, and dissolved gas content.

  13. Variable-temperature independently driven four-tip scanning tunneling microscope

    International Nuclear Information System (INIS)

    Hobara, Rei; Nagamura, Naoka; Hasegawa, Shuji; Matsuda, Iwao; Yamamoto, Yuko; Miyatake, Yutaka; Nagamura, Toshihiko

    2007-01-01

    The authors have developed an ultrahigh vacuum (UHV) variable-temperature four-tip scanning tunneling microscope (STM), operating from room temperature down to 7 K, combined with a scanning electron microscope (SEM). Four STM tips are mechanically and electrically independent and capable of positioning in arbitrary configurations in nanometer precision. An integrated controller system for both of the multitip STM and SEM with a single computer has also been developed, which enables the four tips to operate either for STM imaging independently and for four-point probe (4PP) conductivity measurements cooperatively. Atomic-resolution STM images of graphite were obtained simultaneously by the four tips. Conductivity measurements by 4PP method were also performed at various temperatures with the four tips in square arrangement with direct contact to the sample surface

  14. Effect of tip geometry on photo-electron-emission from nanostructures.

    Science.gov (United States)

    Teki, Ranganath; Lu, Toh-Ming; Koratkar, Nikhil

    2009-03-01

    We show in this paper the strong effect of tip geometry on the photo-electron-emission behavior of nanostructured surfaces. To study the effect of tip geometry we compared the photo-emissivity of Ru and Pt nanorods with pyramidal shaped tips to that of carbon nanorods that display flat top (planar) tips. Flat top architectures gave no significant increase in the emission current, while nanostructures with pyramidal shaped tips showed 3-4 fold increase in photo-emission compared to a thin film of the same material. Pyramidal tip geometries increase the effective surface area that is exposed to the incident photon-flux thereby enhancing the photon-collection probability of the system. Such nano-structured surfaces show promise in a variety of device applications such as photo-detectors, photon counters and photo-multiplier tubes.

  15. 100 Consejos para los Padres (100 Tips for Parents).

    Science.gov (United States)

    Department of Education, Washington, DC.

    Noting that involved parents can improve their children's chances of succeeding in school, this packet of Spanish-language cards offers 100 tips created to help parents become more involved in their child's education. Following a card of general tips on becoming involved, tips are offered in the following topic areas: keeping a child alcohol,…

  16. New Technique for Fabrication of Scanning Single-Electron Transistor Microscopy Tips

    Science.gov (United States)

    Goodwin, Eric; Tessmer, Stuart

    Fabrication of glass tips for Scanning Single-Electron Transistor Microscopy (SSETM) can be expensive, time consuming, and inconsistent. Various techniques have been tried, with varying levels of success in regards to cost and reproducibility. The main requirement for SSETM tips is to have a sharp tip ending in a micron-scale flat face to allow for deposition of a quantum dot. Drawing inspiration from methods used to create tips from optical fibers for Near-Field Scanning Optical Microscopes, our group has come up with a quick and cost effective process for creating SSETM tips. By utilizing hydrofluoric acid to etch the tips and oleic acid to guide the etch profile, optical fiber tips with appropriate shaping can be rapidly prepared. Once etched, electric leads are thermally evaporated onto each side of the tip, while an aluminum quantum dot is evaporated onto the face. Preliminary results using various metals, oxide layers, and lead thicknesses have proven promising.

  17. Self-reported hand hygiene practices, and feasibility and acceptability of alcohol-based hand rubs among village healthcare workers in Inner Mongolia, China.

    Science.gov (United States)

    Li, Y; Wang, Y; Yan, D; Rao, C Y

    2015-08-01

    Good hand hygiene is critical to reduce the risk of healthcare-associated infections. Limited data are available on hand hygiene practices from rural healthcare systems in China. To assess the feasibility and acceptability of sanitizing hands with alcohol-based hand rubs (ABHRs) among Chinese village healthcare workers, and to assess their hand hygiene practice. Five hundred bottles of ABHR were given to village healthcare workers in Inner Mongolia, China. Standardized questionnaires collected information on their work load, availability, and usage of hand hygiene facilities, and knowledge, attitudes, and practices of hand hygiene. In all, 369 (64.2%) participants completed the questionnaire. Although 84.5% of the ABHR recipients believed that receiving the ABHR improved their hand hygiene practice, 78.8% of recipients would pay no more than US$1.5 out of their own pocket (actual cost US$4). The majority (77.2%) who provided medical care at patients' homes never carried hand rubs with them outside their clinics. In general, self-reported hand hygiene compliance was suboptimal, and the lowest compliance was 'before touching a patient'. Reported top three complaints with using ABHR were skin irritation, splashing, and unpleasant residual. Village doctors with less experience practised less hand hygiene. The overall acceptance of ABHR among the village healthcare workers is high as long as it is provided to them for free/low cost, but their overall hand hygiene practice is suboptimal. Hand hygiene education and training is needed in settings outside of traditional healthcare facilities. Published by Elsevier Ltd.

  18. An Airplane Design having a Wing with Fuselage Attached to Each Tip

    Science.gov (United States)

    Spearman, Leroy M.

    2001-01-01

    This paper describes the conceptual design of an airplane having a low aspect ratio wing with fuselages that are attached to each wing tip. The concept is proposed for a high-capacity transport as an alternate to progressively increasing the size of a conventional transport design having a single fuselage with cantilevered wing panels attached to the sides and tail surfaces attached at the rear. Progressively increasing the size of conventional single body designs may lead to problems in some area's such as manufacturing, ground-handling and aerodynamic behavior. A limited review will be presented of some past work related to means of relieving some size constraints through the use of multiple bodies. Recent low-speed wind-tunnel tests have been made of models representative of the inboard-wing concept. These models have a low aspect ratio wing with a fuselage attached to each tip. Results from these tests, which included force measurements, surface pressure measurements, and wake surveys, will be presented herein.

  19. KNOW-BLADE task-3.2 report: Tip shape study

    DEFF Research Database (Denmark)

    Sørensen, Niels N.; Johansen, Jeppe; Conway, S.

    2005-01-01

    For modern rotor blades with their very large aspect ratio, the blade tip is a very limited part of the overall rotor, and as such of limited importance for the overall aerodynamics of the rotor. Even though they may not be very important for the overallpower production, the tip noise can be very...... important for the acoustics of the rotor [15], and the blade tips can as well be important for the aerodynamic damping properties of the rotor blades [13]. Unfortunately, not many options exists for predictingthe aerodynamic behavior of blade tips using computational methods. Experimentally it is di...

  20. Jagged gives endothelial tip cells an edge.

    Science.gov (United States)

    Suchting, Steven; Eichmann, Anne

    2009-06-12

    Sprouting blood vessels have tip cells that lead and stalk cells that follow. Benedito et al. (2009) now show that competition between endothelial cells for the tip position is regulated by glycosylation of Notch receptors and by the opposing actions of the Notch ligands Jagged1 and Delta-like 4.

  1. Electron field emission characteristics of carbon nanotube on tungsten tip

    International Nuclear Information System (INIS)

    Phan Ngoc Hong; Bui Hung Thang; Nguyen Tuan Hong; Phan Ngoc Minh; Lee, Soonil

    2009-01-01

    Electron field emission characteristic of carbon nanotubes on tungsten tip was investigated in 2x10 -6 Torr vacuum. The measurement results showed that the CNTs/W tip could emit electron at 0.7 V/μm (nearly 10 times lower than that of the W tip itself) and reach up to 26 μA at the electric field of 1 V/μm. The emission characteristic follows the Fowler-Nordheim mechanism. Analysis of the emission characteristic showed that the CNTs/W tip has a very high value of field enhancement factor (β = 4.1 x 10 4 cm -1 ) that is much higher than that of the tungsten tip itself. The results confirmed the excellent field emission behavior of the CNTs materials and the CNTs/W tip is a prospective candidate for advanced electron field emitter.

  2. Tip cells: master regulators of tubulogenesis?

    Science.gov (United States)

    Weavers, Helen; Skaer, Helen

    2014-07-01

    The normal development of an organ depends on the coordinated regulation of multiple cell activities. Focusing on tubulogenesis, we review the role of specialised cells or groups of cells that are selected from within tissue primordia and differentiate at the outgrowing tips or leading edge of developing tubules. Tip or leading cells develop distinctive patterns of gene expression that enable them to act both as sensors and transmitters of intercellular signalling. This enables them to explore the environment, respond to both tissue intrinsic signals and extrinsic cues from surrounding tissues and to regulate the behaviour of their neighbours, including the setting of cell fate, patterning cell division, inducing polarity and promoting cell movement and cell rearrangements by neighbour exchange. Tip cells are also able to transmit mechanical tension to promote tissue remodelling and, by interacting with the extracellular matrix, they can dictate migratory pathways and organ shape. Where separate tubular structures fuse to form networks, as in the airways of insects or the vascular system of vertebrates, specialised fusion tip cells act to interconnect disparate elements of the developing network. Finally, we consider their importance in the maturation of mature physiological function and in the development of disease. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Influence of artificial tip perturbation on asymmetric vortices flow over a chined fuselage

    Directory of Open Access Journals (Sweden)

    Shi Wei

    2015-08-01

    Full Text Available An experimental study was conducted with the aim of understanding behavior of asymmetric vortices flow over a chined fuselage. The tests were carried out in a wind tunnel at Reynolds number of 1.87 × 105 under the conditions of high angles of attack and zero angle of sideslip. The results show that leeward vortices flow becomes asymmetric vortices flow when angle of attack increases over 20°. The asymmetric vortices flow is asymmetry of two forebody vortices owing to the increase of angle of attack but not asymmetry of vortex breakdown which appears when angle of attack is above 35°. Asymmetric vortices flow is sensitive to tip perturbation and is non-deterministic due to randomly distributed natural minute geometrical irregularities on the nose tip within machining tolerance. Deterministic asymmetric vortices flow can be obtained by attaching artificial tip perturbation which can trigger asymmetric vortices flow and decide asymmetric vortices flow pattern. Triggered by artificial tip perturbation, the vortex on the same side with perturbation is in a higher position, and the other vortex on the opposite side is in a lower position. Vortex suction on the lower vortex side is larger, which corresponds to a side force pointing to the lower vortex side.

  4. Effect of cavitation on flow structure of a tip vortex

    Science.gov (United States)

    Matthieu, Dreyer; Reclari, Martino; Farhat, Mohamed

    2013-11-01

    Tip vortices, which may develop in axial turbines and marine propellers, are often associated with the occurrence of cavitation because of the low pressure in their core. Although this issue has received a great deal of attention, it is still unclear how the phase transition affects the flow structure of such a vortex. In the present work, we investigate the change of the vortex structure due to cavitation incipience. The measurement of the velocity field is performed in the case of a tip vortex generated by an elliptical hydrofoil placed in the test section of EPFL high speed cavitation tunnel. To this end, a 3D stereo PIV is used with fluorescent seeding particles. A cost effective method is developed to produce in-house fluorescent seeding material, based on polyamide particles and Rhodamine-B dye. The amount of cavitation in the vortex core is controlled by the inlet pressure in the test section, starting with the non-cavitating case. We present an extensive analysis of the vorticity distribution, the vortex intensity and core size for various cavitation developments. This research is supported by CCEM and swisselectric research.

  5. The transjugular intrahepatic portosystemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Owen, A.R.; Stanley, A.J.; Vijayananthan, A.; Moss, J.G.

    2009-01-01

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  6. The transjugular intrahepatic portosystemic shunt (TIPS)

    Energy Technology Data Exchange (ETDEWEB)

    Owen, A.R. [Department of Radiology, Austin Health, Heidelberg, Melbourne (Australia)], E-mail: andrewowen@doctors.org.uk; Stanley, A.J. [Department of Gastroenterology, Glasgow Royal Infirmary, Glasgow (United Kingdom); Vijayananthan, A. [Department of Biomedical Imaging, University of Malaya, Kuala Lumpur (Malaysia); Moss, J.G. [Department of Radiology, Gartnavel General Hospital, Glasgow (United Kingdom)

    2009-07-15

    The creation of an intrahepatic portosystemic shunt via a transjugular approach (TIPS) is an interventional radiological procedure used to treat the complications of portal hypertension. TIPS insertion is principally indicated to prevent or arrest variceal bleeding when medical or endoscopic treatments fail, and in the management refractory ascites. This review discusses the development and execution of the technique, with focus on its clinical efficacy. Patient selection, imaging surveillance, revision techniques, and complications are also discussed.

  7. Multi-scale analysis of deformation behavior at SCC crack tip (3) (Contract research)

    International Nuclear Information System (INIS)

    Kaji, Yoshiyuki; Miwa, Yukio; Tsukada, Takashi; Hayakawa, Masao; Nagashima, Nobuo

    2008-08-01

    In recent years, incidents of the stress corrosion cracking (SCC) were frequently reported that occurred to the various components of domestic boiling water reactors (BWR), and the cause investigation and measure become the present important issue. By the Japan nuclear energy safety organization (JNES), a research project on the intergranular SCC (IGSCC) in nuclear grade stainless steels (henceforth, IGSCC project) is under enforcement from a point of view to secure safety and reliability of BWR, and SCC growth data of low carbon stainless steels are being accumulated for the weld part or the work-hardened region adjacent to the weld metal. In the project, it has been an important subject to guarantee the validity of accumulated SCC data. At a crack tip of SCC in compact tension (CT) type specimen used for the SCC propagation test, a macroscopic plastic region is formed where heterogeneity of microstructure developed by microscopic sliding and dislocations is observed. However, there is little quantitative information on the plastic region, and therefore, to assess the data of macroscopic SCC growth rate and the validity of propagation test method, it is essentially required to investigate the plastic region at the crack tip in detail from a microscopic viewpoint. This report describes a result of the research conducted by the Japan Atomic Energy Agency and the National Institute for Materials Science under contract with JNES that was concerned with a multi-scale analysis of plastic deformation behavior at the crack tip of SCC. The research was carried out to evaluate the validity of the SCC growth data acquired in the IGSCC project based on a mechanistic understanding of SCC. For the purpose, in this research, analyses of the plastic deformation behavior and microstructure around the crack tip were performed in a nano-order scale. The hardness measured in nano, meso and macro scales was employed as a common index of the strength, and the essential data necessary

  8. ZBrush Professional Tips and Techniques

    CERN Document Server

    Gaboury, Paul

    2012-01-01

    Learn to work effectively and creatively with all versions of ZBrush! ZBrush is used by top artists in Hollywood to model and sculpt characters in such films as Avatar, Iron Man, and Pirates of the Caribbean. In addition, this amazing technology is also used in jewelry design, forensic science, aerospace, video games, toy creation, and the medical field. Written by Pixologic's in-house ZBrush expert Paul Gaboury, this full-color, beautifully illustrated guide provides you with the ultimate tips and tricks to maximize your use of all versions of ZBrush. Reveals numerous little-known tips and tr

  9. Back-to-School Health Tips: Exercise and Sleep

    Science.gov (United States)

    ... up the same times each day. Keep room temperature on the cool side. A TV or computer in the bedroom can be a distraction. Read More "Back-to-School" Articles Health Tips: Immunizations / Health Tips: Exercise and ...

  10. Lifting Safety: Tips To Help Prevent Back Injuries

    Science.gov (United States)

    ... Prevent Back Injuries Lifting Safety: Tips to Help Prevent Back Injuries Share Print Back injuries are common problems at work, home, and play. They can be caused by accidents or improper lifting technique. Below are tips to ...

  11. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    International Nuclear Information System (INIS)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R.

    2015-01-01

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  12. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    Energy Technology Data Exchange (ETDEWEB)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R., E-mail: dkillelea@luc.edu [Department of Chemistry and Biochemistry, Loyola University Chicago, 1068 W. Sheridan Rd., Chicago, Illinois 60660 (United States)

    2015-03-15

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  13. Fabrication of silver tips for scanning tunneling microscope induced luminescence.

    Science.gov (United States)

    Zhang, C; Gao, B; Chen, L G; Meng, Q S; Yang, H; Zhang, R; Tao, X; Gao, H Y; Liao, Y; Dong, Z C

    2011-08-01

    We describe a reliable fabrication procedure of silver tips for scanning tunneling microscope (STM) induced luminescence experiments. The tip was first etched electrochemically to yield a sharp cone shape using selected electrolyte solutions and then sputter cleaned in ultrahigh vacuum to remove surface oxidation. The tip status, in particular the tip induced plasmon mode and its emission intensity, can be further tuned through field emission and voltage pulse. The quality of silver tips thus fabricated not only offers atomically resolved STM imaging, but more importantly, also allows us to perform challenging "color" photon mapping with emission spectra taken at each pixel simultaneously during the STM scan under relatively small tunnel currents and relatively short exposure time.

  14. Graded-index fiber tip optical tweezers: numerical simulation and trapping experiment.

    Science.gov (United States)

    Gong, Yuan; Ye, Ai-Yan; Wu, Yu; Rao, Yun-Jiang; Yao, Yao; Xiao, Song

    2013-07-01

    Optical fiber tweezers based on a graded-index multimode fiber (GIMMF) tip is proposed. Light propagation characteristics and gradient force distribution near the GIMMF tip are numerically investigated, which are further compared with that of optical fiber tips based on conventional single mode fibers. The simulated results indicated that by selecting optimal GIMMF length, the gradient force of the GIMMF tip tweezers is about 4 times higher than that of the SMF tip tweezers with a same shape. To prove the feasibility of such a new concept, optical trapping of yeast cells with a diameter of ~5 μm using the chemically-etched GIMMF tip is experimentally demonstrated and the trapping force is also calculated.

  15. High precision attachment of silver nanoparticles on AFM tips by dielectrophoresis.

    Science.gov (United States)

    Leiterer, Christian; Wünsche, Erik; Singh, Prabha; Albert, Jens; Köhler, Johann M; Deckert, Volker; Fritzsche, Wolfgang

    2016-05-01

    AFM tips are modified with silver nanoparticles using an AC electrical field. The used technique works with sub-micron precision and also does not require chemical modification of the tip. Based on the electrical parameters applied in the process, particle density and particle position on the apex of the tip can be adjusted. The feasibility of the method is proven by subsequent tip-enhanced Raman spectroscopy (TERS) measurements using the fabricated tips as a measurement probe. Since this modification process itself does not require any lithographic processing, the technique can be easily adapted to modify AFM tips with a variety of nanostructures with pre-defined properties, while being parallelizable for a potential commercial application.

  16. The influence of polysilane chemical structure on optical properties, rubbed film morphology and LC alignment

    Directory of Open Access Journals (Sweden)

    M. Soroceanu

    2015-05-01

    Full Text Available Polysilane films were prepared by the drop casting method and their optical and morphological properties have been analyzed in order to investigate their suitability as alignment layers for nematic molecules. The samples do not absorb the radiations in the visible domain, particularly those containing methylhydrosilyl units, and present a transmittance of about 90% starting from 390 to 1100 nm. The optical band-gap is higher than 3.26 eV for all polysilanes indicating a low probability of optical absorption processes in the visible range. The morphology of the pristine samples shows isotropically distributed granular formations. The polymer surface was oriented by rubbing with two types of velvet: one with short fibers and the other with long fibers. The latter generates higher surface anisotropy, as shown by the reduction of the surface texture direction index values. The presence of methylhydrosilyl units allows a denser packing of the polymer structure and thus finer surface periodicities, leading to better orientation of the nematic molecules on the polysilane surface.

  17. A Blade Tip Timing Method Based on a Microwave Sensor

    Directory of Open Access Journals (Sweden)

    Jilong Zhang

    2017-05-01

    Full Text Available Blade tip timing is an effective method for blade vibration measurements in turbomachinery. This method is increasing in popularity because it is non-intrusive and has several advantages over the conventional strain gauge method. Different kinds of sensors have been developed for blade tip timing, including optical, eddy current and capacitance sensors. However, these sensors are unsuitable in environments with contaminants or high temperatures. Microwave sensors offer a promising potential solution to overcome these limitations. In this article, a microwave sensor-based blade tip timing measurement system is proposed. A patch antenna probe is used to transmit and receive the microwave signals. The signal model and process method is analyzed. Zero intermediate frequency structure is employed to maintain timing accuracy and dynamic performance, and the received signal can also be used to measure tip clearance. The timing method uses the rising and falling edges of the signal and an auto-gain control circuit to reduce the effect of tip clearance change. To validate the accuracy of the system, it is compared experimentally with a fiber optic tip timing system. The results show that the microwave tip timing system achieves good accuracy.

  18. Tipping news in information accumulation system

    Science.gov (United States)

    Shin, J. K.

    2010-05-01

    As a continuous opinion dynamics model, the information accumulation system (IAS) includes three basic mechanisms of the news, the inheritance and the diffusion as contributing to the information accumulation process of a system. A system is composed of agents who diffuse information through internal interaction, while each of them has incomplete memory or inheritance rate. The news comes from external sources of information, such as mass media. Previously the model IAS was studied only for the small news problems. In this study, a tipping news problem is considered. A key question of the problem is: what is the minimum strength of advertisement that can tip the minority opinion to a majority one? Dynamics of the IAS is briefly revisited with a special interest on nonlinear behavior of the model. In particular, it is shown that a discrete map of the IAS for a single color problem can be transformed into a logistic map, from which the dynamics of the IAS can be better understood. To show the applicability of the IAS model, the result is applied to explain the concept of the critical population size, which claims that there is a minimum population size for a social knowledge system to be continuously inherited without being lost. And critical size of the tipping news is found analytically in terms of IAS parameters. Some of the key results from the present study are compared in detail with the results from the Brownian particle model, which is believed to be the most similar model to the IAS. The concept of tipping news is used to show that a traditional society can tip at an exceptionally low inter-community exposure. Finally, the result was applied to the language competition problem.

  19. Travel Tips Help IBS Sufferers Enjoy Their Vacations

    Science.gov (United States)

    ... can feel more in control when traveling." IFFGD's travel tips include: Allow enough time in the morning to get to the airport ... Heartache 2004-0929 Norton Honored 2004-0525 IBS Travel Tips ... Real World 2001-1119 Heartburn or Heart Attack Commentary ...

  20. Stress corrosion crack tip microstructure in nickel-based alloys

    International Nuclear Information System (INIS)

    Shei, S.A.; Yang, W.J.

    1994-04-01

    Stress corrosion cracking behavior of several nickel-base alloys in high temperature caustic environments has been evaluated. The crack tip and fracture surfaces were examined using Auger/ESCA and Analytical Electron Microscopy (AEM) to determine the near crack tip microstructure and microchemistry. Results showed formation of chromium-rich oxides at or near the crack tip and nickel-rich de-alloying layers away from the crack tip. The stress corrosion resistance of different nickel-base alloys in caustic may be explained by the preferential oxidation and dissolution of different alloying elements at the crack tip. Alloy 600 (UNS N06600) shows good general corrosion and intergranular attack resistance in caustic because of its high nickel content. Thermally treated Alloy 690 (UNS N06690) and Alloy 600 provide good stress corrosion cracking resistance because of high chromium contents along grain boundaries. Alloy 625 (UNS N06625) does not show as good stress corrosion cracking resistance as Alloy 690 or Alloy 600 because of its high molybdenum content

  1. Assessment of transpulmonary absorption of ethanol from alcohol-based hand rub.

    Science.gov (United States)

    Hautemanière, Alexis; Ahmed-Lecheheb, Djihane; Cunat, Lisiane; Hartemann, Philippe

    2013-03-01

    Alcohol-based hand rubs (ABHRs) have been associated with a reduction of nosocomial infections. Despite the worldwide introduction of these products in health care settings, the aim of this study was to assess the transpulmonary absorption of ethanol contains in ABHRs used by health care workers (HCWs) in real conditions of work shift. Twenty-six HCWs of Nancy University Hospital were included. Research consisted in monitoring participants during 4 hours of work shift to assess their exposure to ethanol. The measurement of ethanol vapors in exhaled breath was performed using a class B ethylometer (Alco-Sensor FST). Ethanol concentration in inhaled breath was measured using Gilian pump LFS-113. Concentration of ethanol, acetaldehyde, and acetate in blood and urine samples were determined using gas chromatography with flame ionization detector. Participants were 12% male and 88% female. The mean age was 40 ± 8 years. None of the employees included in the study presented any traces of ethanol or its metabolites in the blood or urine. Ethanol (0.08 ± 0.07 mg/L) was detected in the breath of 10 HCWs at 1 to 2 minutes postexposure. The mean concentration of ethanol in the inhaled air was 46.2 mg/m. Absorption of ethanol vapor from ABHRs among HCWs during their care activities was not detected. Quantification of ethanol fumes inhaled during 4 hours of work shift was below the regulatory limitations of exposure to ethanol. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Life form succession in plant communities on colliery waste tips

    Energy Technology Data Exchange (ETDEWEB)

    Down, C G

    1973-01-01

    Five disused colliery waste tips in the Somerset Coalfield, 12, 15, 21, 55 and 98 years old, respectively, were examined to determine the life forms of the naturally-occurring vascular plant species. Hemicryptophytes comprised between 68 and 79% of the number of species on each tip. Rosette hemicryptophytes comprised 31.8% of the species on the 12-year tip, declining to 11.8% on the 98-year tip. It is suggested that artificial planting of rosette hemicryptophytes may be beneficial in reclamation schemes. 3 tables.

  3. Search Tips: MedlinePlus

    Science.gov (United States)

    ... of this page: https://medlineplus.gov/searchtips.html Search Tips To use the sharing features on this page, please enable JavaScript. How do I search MedlinePlus? The search box appears at the top ...

  4. Ultra high tip speed (670.6 m/sec) fan stage with composite rotor: Aerodynamic and mechanical design

    Science.gov (United States)

    Halle, J. E.; Burger, G. D.; Dundas, R. E.

    1977-01-01

    A highly loaded, single-stage compressor having a tip speed of 670.6 m/sec was designed for the purpose of investigating very high tip speeds and high aerodynamic loadings to obtain high stage pressure ratios at acceptable levels of efficiency. The design pressure ratio is 2.8 at an adiabatic efficiency of 84.4%. Corrected design flow is 83.4 kg/sec; corrected design speed is 15,200 rpm; and rotor inlet tip diameter is 0.853 m. The rotor uses multiple-circular-arc airfoils from 0 to 15% span, precompression airfoils assuming single, strong oblique shocks from 21 to 43% span, and precompression airfoils assuming multiple oblique shocks from 52% span to the tip. Because of the high tip speeds, the rotor blades are designed to be fabricated of composite materials. Two composite materials were investigated: Courtaulds HTS graphite fiber in a Kerimid 601 polyimide matrix and the same fibers in a PMR polyimide matrix. In addition to providing a description of the aerodynamic and mechanical design of the 670.0 m/sec fan, discussion is presented of the results of structural tests of blades fabricated with both types of matrices.

  5. Influence of CVD diamond tips and Er:YAG laser irradiation on bonding of different adhesive systems to dentin.

    Science.gov (United States)

    da Silva, Melissa Aline; Di Nicolo, Rebeca; Barcellos, Daphne Camara; Batista, Graziela Ribeiro; Pucci, Cesar Rogerio; Rocha Gomes Torres, Carlos; Borges, Alessandra Bühler

    2013-01-01

    The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm(2). The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

  6. Restaurant Dining: Seven Tips for Staying Gluten Free

    Science.gov (United States)

    GiG Education Bulletin Restaurant Dining: Seven Tips for Staying Gluten-Free Updated May 2014 Tips for Dining Away from Home 1. Selection of ... a number of factors, including the type of restaurant you choose. • Be careful in restaurants where language ...

  7. Incontinence Treatment: Dietary Tips

    Science.gov (United States)

    ... helpful, please consider supporting IFFGD with a small tax-deductible donation. Lifestyle Changes Dietary Tips Medication Bowel ... arises requiring an expert’s care. © Copyright 1998-2018 International Foundation for Functional Gastrointestinal Disorders, Inc. (IFFGD). All ...

  8. Customized atomic force microscopy probe by focused-ion-beam-assisted tip transfer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Andrew; Butte, Manish J., E-mail: manish.butte@stanford.edu [Department of Pediatrics, Division of Immunology, Allergy and Rheumatology, Stanford University, Stanford, California 94305 (United States)

    2014-08-04

    We present a technique for transferring separately fabricated tips onto tipless atomic force microscopy (AFM) cantilevers, performed using focused ion beam-assisted nanomanipulation. This method addresses the need in scanning probe microscopy for certain tip geometries that cannot be achieved by conventional lithography. For example, in probing complex layered materials or tall biological cells using AFM, a tall tip with a high-aspect-ratio is required to avoid artifacts caused by collisions of the tip's sides with the material being probed. We show experimentally that tall (18 μm) cantilever tips fabricated by this approach reduce squeeze-film damping, which fits predictions from hydrodynamic theory, and results in an increased quality factor (Q) of the fundamental flexural mode. We demonstrate that a customized tip's well-defined geometry, tall tip height, and aspect ratio enable improved measurement of elastic moduli by allowing access to low-laying portions of tall cells (T lymphocytes). This technique can be generally used to attach tips to any micromechanical device when conventional lithography of tips cannot be accomplished.

  9. A numerical study of non-linear crack tip parameters

    Directory of Open Access Journals (Sweden)

    F.V. Antunes

    2015-07-01

    Full Text Available Crack closure concept has been widely used to explain different issues of fatigue crack propagation. However, different authors have questioned the relevance of crack closure and have proposed alternative concepts. The main objective here is to check the effectiveness of crack closure concept by linking the contact of crack flanks with non-linear crack tip parameters. Accordingly, 3D-FE numerical models with and without contact were developed for a wide range of loading scenarios and the crack tip parameters usually linked to fatigue crack growth, namely range of cyclic plastic strain, crack tip opening displacement, size of reversed plastic zone and total plastic dissipation per cycle, were investigated. It was demonstrated that: i LEFM concepts are applicable to the problem under study; ii the crack closure phenomenon has a great influence on crack tip parameters decreasing their values; iii the Keff concept is able to explain the variations of crack tip parameters produced by the contact of crack flanks; iv the analysis of remote compliance is the best numerical parameter to quantify the crack opening level; v without contact there is no effect of stress ratio on crack tip parameters. Therefore it is proved that the crack closure concept is valid.

  10. LOTTTTUCE: Layer Oriented Tip-Tilt Turbulence Tomography using Covariance and Elevation

    International Nuclear Information System (INIS)

    Lai, Olivier; Hayano, Yutaka; Oya, Shin; Chun, Mark; Lu, Jessica R; Toomey, Douglas

    2015-01-01

    LOTTTTUCE is based upon the fact that turbulence at the pupil produces correlated tip-tilt motion over the entire field (averaging the tip-tilt across the widest field possible gives the strength of the turbulence at the telescope), while the on-axis (any axis) image motion measures the integrated tip-tilt over the line of sight (single stars provide the variance of the tip-tilt, which allows to infer the integrated seeing). Between these two extremes, the amount of correlation across a given field size is the integral of the turbulence from the ground to the altitude where the tip-tilt decorrelates over the meta-pupil. Differentiating the altitude- integrated tip-tilt with respect to altitude generates an estimate of tip-tilt (hence turbulence, assuming Kolmogorov properties) at each altitude. Alternately, the 3D Fourier transform of a data cube containing the time evolution of the tip (or tilt) across the field allows to determine the amount of energy for “field” frequencies (in other words, the integrated seeing across each same size patches) and the temporal spectrum of each of these features. Differentiating the spectrum with respect to spatial frequency would provide the amount of energy, as well as speed and direction, of each layer. The LOTTTTUCE method is a novel method of measuring the vertical turbulence profile that uses wide field tip-tilt information such as that provided by Pan-STARRS. However, the method also has limitations due to tip-tilt decorrelation as a function of meta-pupil overlap, finite outer scale, and non-Kolmogorov power spectrum. (paper)

  11. Rhinoplasty: a simplified, three-stitch, open tip suture technique. Part I: primary rhinoplasty.

    Science.gov (United States)

    Daniel, R K

    1999-04-01

    Tip suture techniques offer a reliable and dramatic method of tip modification without needing to interrupt the alar rim strip or add tip grafts. The present simplified three-stitch technique consists of the following: (1) a strut suture to fix the columella strut between the crura, (2) bilateral domal creation sutures to create tip definition, and (3) a domal equalization suture to narrow and align the domes. If required, columella septal sutures can be added; either a dorsal rotational suture or a transfixion projection suture can be used. This simplified method represents a refinement based on more than 13 years of experience with tip suture techniques. It does not require a complex operative sequence or specialized sutures. Primary indications are moderate tip deformities of inadequate definition and excessive width and certain specific tip deformities, including the parenthesis tip and nostril/tip disproportion. The primary contraindications are for patients with minor tip deformities that are best done through a closed approach and those with severe tip deformities requiring an open structure graft. The technique is simple, efficacious, and easily learned.

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS): Current Status and Future Possibilities

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Quiroga, Jorge; Herrero, Jose Ignacio; Benito, Alberto

    2002-01-01

    Since the insertion of the first TIPS in 1989 much has been learned about this therapeutic procedure. It has an established role for the treatment of some complications of portal hypertension: prevention of recurrent variceal bleeding and rescue of patients with acute uncontrollable variceal bleeding. In addition TIPS is useful for Budd-Chiari syndrome, refractory ascites and hepatorenal syndrome, although its specific role in these indications remains to be definitively established. However, the decrease in sinusoidal blood flow induced by TIPS can lead to the patient developing hepatic encephalopathy and liver failure in some cases. Therefore, TIPS should be used with caution in patients with very poor liver function. From a technical point of view, successful placement of TIPS is achieved in more than 98% of cases by experienced groups. At present, evaluation of TIPS dysfunction based on morphology probably leads to an overdiagnosis of this complication since most of these cases are not associated with clinical manifestations (recurrent bleeding or refractory ascites). The major disadvantage of TIPS remains its poor long-term patency requiring a mandatory surveillance program. The indicator for shunt function/malfunction should be the portosystemic pressure gradient, which is best assessed by intravascular measurements. Shunt obstructions may be prevented or reduced by the use of stent-grafts in the future

  13. Ten Tips for Parents to Help Their Children Avoid Teen Pregnancy

    Science.gov (United States)

    ... we do » Resource library » Ten tips for parents Ten Tips for Parents to Help Their Children Avoid Teen Pregnancy Publication Created with Sketch. Ten Tips for Parents to Help Their Children Avoid ...

  14. Robustness of tungsten single atom tips to thermal treatment and air exposure

    Energy Technology Data Exchange (ETDEWEB)

    Vesa, Cristian; Urban, Radovan [Department of Physics, University of Alberta, Edmonton, Alberta, Canada T6G 2G7 (Canada); National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta, Canada T6G 2M9 (Canada); Pitters, Jason L., E-mail: jason.pitters@nrc-cnrc.gc.ca [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta, Canada T6G 2M9 (Canada); Wolkow, Robert A. [Department of Physics, University of Alberta, Edmonton, Alberta, Canada T6G 2G7 (Canada); National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta, Canada T6G 2M9 (Canada)

    2014-05-01

    Highlights: • W(1 1 1) single atom tips (SATs) were exposed to air. • SATs could be regenerated by field assisted chemical etching after exposure. • Warming procedures to minimize tip contamination were developed. • Degassing temperatures for air exposed tips were established. • Tip faceting occurred when SATs and unetched tips were annealed above 1200 °C. - Abstract: Experiments aimed at assessing the robustness of nitrogen-etched, single-atom tips (SATs) prepared using W(1 1 1) single crystal wire were performed. Our experiments showed that single-atoms tips sustain minimal damage when exposed to atmospheric conditions and can be readily and quickly nitrogen-etched to single-atom tips thereafter. The SATs can be annealed at temperatures up to 1100 °C with minimal shape changes. Moreover, annealing temperatures in excess of 1200 °C resulted in an apex faceting which may prove important in further single-atom tip creation. Procedures for warming of the SATs from operating temperatures of 80 K were also evaluated to determine conditions that limit tip contamination. These results show that SATS could be fabricated in a dedicated vacuum system and subsequently transferred to other instruments where they would undergo a brief conditioning procedure to recover the single-atom apex configuration prior to being subjected to operating conditions.

  15. Homogeneous nucleation of water in argon. Nucleation rate computation from molecular simulations of TIP4P and TIP4P/2005 water model.

    Science.gov (United States)

    Dumitrescu, Lucia R; Smeulders, David M J; Dam, Jacques A M; Gaastra-Nedea, Silvia V

    2017-02-28

    Molecular dynamics (MD) simulations were conducted to study nucleation of water at 350 K in argon using TIP4P and TIP4P/2005 water models. We found that the stability of any cluster, even if large, strongly depends on the energetic interactions with its vicinity, while the stable clusters change their composition almost entirely during nucleation. Using the threshold method, direct nucleation rates are obtained. Our nucleation rates are found to be 1.08×10 27 cm -3 s -1 for TIP4P and 2.30×10 27 cm -3 s -1 for TIP4P/2005. The latter model prescribes a faster dynamics than the former, with a nucleation rate two times larger due to its higher electrostatic charges. The non-equilibrium water densities derived from simulations and state-of-art equilibrium parameters from Vega and de Miguel [J. Chem. Phys. 126, 154707 (2007)] are used for the classical nucleation theory (CNT) prediction. The CNT overestimates our results for both water models, where TIP4P/2005 shows largest discrepancy. Our results complement earlier data at high nucleation rates and supersaturations in the Hale plot [Phys. Rev. A 33, 4156 (1986)], and are consistent with MD data on the SPC/E and the TIP4P/2005 model.

  16. With Protein Foods, Variety Is Key: 10 Tips for Choosing Protein

    Science.gov (United States)

    ... Dietary Guidelines Communicator’s Guide 10 Tips: Vary Your Protein Routine You are here Home 10 Tips: Vary ... Protein Routine Print Share 10 Tips: Vary Your Protein Routine Protein foods include both animal (meat, poultry, ...

  17. An IPMC microgripper with integrated actuator and sensing for constant finger-tip displacement

    International Nuclear Information System (INIS)

    Gonzalez, Carlos; Lumia, Ron

    2015-01-01

    Ionic polymer metal composite (IPMC) is a type of smart material that has gained the interest of many researchers due to its ability to achieve large displacements under small input voltages, usually less than 2.5 V. This has motivated the use of these materials in microsystems and systems in the millimeter scale, such as microgrippers. However, few of the control techniques developed thus far have considered the feasibility of using IPMCs in closed loop systems without the need of oversized external sensors. This paper presents a control scheme for a two-finger IPMC microgripper that accomplishes constant finger-tip displacements without external sensors. This scheme generates a displacement-dependent, time varying reference signal to obtain constant finger-tip displacements applied by a separate actuated IPMC. This actuator uses a PID controller tuned with a model-free approach, and is gain scheduled to span up to 1 mm finger-tip displacements. The microgripper achieves zero steady state error for finger-tip displacements on the tuned values of the PID controller. The gain scheduled PID controller is tested and results show zero steady state error to 0.25 mm displacements, and 15 and 20% steady state error when referenced to deflection of 0.45 and 0.75 mm, respectively. This shows that there is great confidence and validity of the control scheme, especially when tracking small reference deflections. (paper)

  18. Alar setback technique: a controlled method of nasal tip deprojection.

    Science.gov (United States)

    Foda, H M

    2001-11-01

    To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires

  19. The perceptions of employees towards tipping and motivation in the hotel industry

    Directory of Open Access Journals (Sweden)

    Kazembe Clotildah

    2014-01-01

    Full Text Available Restaurant tipping has been taken as a bone of contention which discriminates front and back employees involved with the service delivery in a hotel set- up. Monetary benefits affect worker motivation to some extent. Hence the study sought to analyze employee views on tipping and motivation. A lot of confusion and abhorrence has been created as to whom exactly should benefit from the tips servers get from guests. Qualitative research design was used to assess the extent to which tips are perceived as a reward for good service and how this influences worker motivation. Results showed that tipping is a two barreled tool where it can be a motivational tool to those who are tipped and a demotivator to those who are not tipped. The implication of the study is a service charge system to share tips is required to motivate all employees since the guest experience is a product of collective effort from almost all the employees in a hotel establishment.

  20. Tips for Starting Physical Activity

    Science.gov (United States)

    ... Legislative Information Advisory & Coordinating Committees Strategic Plans & Reports Research Areas FAQs ... Starting Physical Activity Related Topics Section Navigation Tips to Help You Get Active ...

  1. Pictorial essay: trans-jugular intra-hepatic porto-systemic shunt (TIPS)

    International Nuclear Information System (INIS)

    Rao Anuradha, T.N.; Rastogi, H.; Pandey, U.C.

    2001-01-01

    TIPS is an interventional radiologic method of creating a portosystemic shunt by percutaneous means. It is a relatively new weapon in the armamentarium of the management of portal hypertension with variceal bleeding or intractable ascites. Using needles, angioplasty balloon catheters and expandable metallic stents, a shunt is established directly inside the liver parenchyma connecting a large hepatic vein with a main portal vein branch. Depending on the diameter of the expandable stent used, the created TIPS diverts various amounts of portal blood into the systemic circulation and results in significant portal decompression, cessation of hemorrhage from esophageal varices and resolution of ascites. TIPS is not only an effective and safe alternative to shunt surgery but is life saving in cases of variceal hemorrhage. The use of TIPS seems to be a valid alternative to surgery and has several advantages over either esophageal transection or surgical shunts. TIPS avoids a general anesthetic, laparotomy, and disruption of the hepatic venous system that may adversely affect subsequent hepatic transplantation. TIPS has been performed on patients without interfering with successful transplantation

  2. Sharp tipped plastic hollow microneedle array by microinjection moulding

    Science.gov (United States)

    Yung, K. L.; Xu, Yan; Kang, Chunlei; Liu, H.; Tam, K. F.; Ko, S. M.; Kwan, F. Y.; Lee, Thomas M. H.

    2012-01-01

    A method of producing sharp tipped plastic hollow microneedle arrays using microinjection moulding is presented in this paper. Unlike traditional approaches, three mould inserts were used to create the sharp tips of the microneedles. Mould inserts with low surface roughness were fabricated using a picosecond laser machine. Sharp tipped plastic hollow microneedles 500 µm in height were fabricated using a microinjection moulding machine developed by the authors’ group. In addition, the strength of the microneedle was studied by simulation and penetration experiments. Results show that the microneedles can penetrate into skin, delivering liquid successfully without any breakage or severe deformation. Techniques presented in this paper can be used to fabricate sharp tipped plastic hollow microneedle arrays massively with low cost.

  3. Sharp tipped plastic hollow microneedle array by microinjection moulding

    International Nuclear Information System (INIS)

    Yung, K L; Xu, Yan; Kang, Chunlei; Liu, H; Tam, K F; Ko, S M; Kwan, F Y; Lee, Thomas M H

    2012-01-01

    A method of producing sharp tipped plastic hollow microneedle arrays using microinjection moulding is presented in this paper. Unlike traditional approaches, three mould inserts were used to create the sharp tips of the microneedles. Mould inserts with low surface roughness were fabricated using a picosecond laser machine. Sharp tipped plastic hollow microneedles 500 µm in height were fabricated using a microinjection moulding machine developed by the authors’ group. In addition, the strength of the microneedle was studied by simulation and penetration experiments. Results show that the microneedles can penetrate into skin, delivering liquid successfully without any breakage or severe deformation. Techniques presented in this paper can be used to fabricate sharp tipped plastic hollow microneedle arrays massively with low cost. (paper)

  4. Twelve tips for "flipping" the classroom.

    Science.gov (United States)

    Moffett, Jennifer

    2015-04-01

    The flipped classroom is a pedagogical model in which the typical lecture and homework elements of a course are reversed. The following tips outline the steps involved in making a successful transition to a flipped classroom approach. The tips are based on the available literature alongside the author's experience of using the approach in a medical education setting. Flipping a classroom has a number of potential benefits, for example increased educator-student interaction, but must be planned and implemented carefully to support effective learning.

  5. Optical properties of a tip-induced quantum dot

    NARCIS (Netherlands)

    Kemerink, M.; Sauthoff, K.; Koenraad, P.M.; Gerritsen, J.W.; Kempen, van H.; Fomin, V.M.; Wolter, J.H.; Devreese, J.T.; Miura, N.; Ando, T.

    2001-01-01

    We have performed optical spectroscopy measurements on an STM-tip-induced quantum dot. The dominant confinement in the (hole) quantum dot is in the direction parallel to the tip axis. Electron confinement is achieved by a sub-surface AlGaAs barrier. Current dependent measurements indicate that

  6. Tip-enhanced Raman mapping with top-illumination AFM.

    Science.gov (United States)

    Chan, K L Andrew; Kazarian, Sergei G

    2011-04-29

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of ∼ 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  7. Tip-enhanced Raman mapping with top-illumination AFM

    Energy Technology Data Exchange (ETDEWEB)

    Chan, K L Andrew; Kazarian, Sergei G, E-mail: s.kazarian@imperial.ac.uk [Department of Chemical Engineering, Imperial College London, SW7 2AZ (United Kingdom)

    2011-04-29

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of {approx} 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  8. Tip-enhanced Raman mapping with top-illumination AFM

    International Nuclear Information System (INIS)

    Chan, K L Andrew; Kazarian, Sergei G

    2011-01-01

    Tip-enhanced Raman mapping is a powerful, emerging technique that offers rich chemical information and high spatial resolution. Currently, most of the successes in tip-enhanced Raman scattering (TERS) measurements are based on the inverted configuration where tips and laser are approaching the sample from opposite sides. This results in the limitation of measurement for transparent samples only. Several approaches have been developed to obtain tip-enhanced Raman mapping in reflection mode, many of which involve certain customisations of the system. We have demonstrated in this work that it is also possible to obtain TERS nano-images using an upright microscope (top-illumination) with a gold-coated Si atomic force microscope (AFM) cantilever without significant modification to the existing integrated AFM/Raman system. A TERS image of a single-walled carbon nanotube has been achieved with a spatial resolution of ∼ 20-50 nm, demonstrating the potential of this technique for studying non-transparent nanoscale materials.

  9. 29 CFR 531.52 - General characteristics of “tips.”

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false General characteristics of âtips.â 531.52 Section 531.52 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR REGULATIONS... Employees § 531.52 General characteristics of “tips.” A tip is a sum presented by a customer as a gift or...

  10. Film cooling effects on the tip flow characteristics of a gas turbine blade

    Directory of Open Access Journals (Sweden)

    Jin Wang

    2015-03-01

    Full Text Available An experimental investigation of the tip flow characteristics between a gas turbine blade tip and the shroud was conducted by a pressure-test system and a particle image velocimetry (PIV system. A three-times scaled profile of the GE-E3 blade with five film cooling holes was used as specimen. The effects on flow characteristics by the rim width and the groove depth of the squealer tip were revealed. The rim widths were (a 0.9%, (b 2.1%, and (c 3.0% of the axial chord, and the groove depths were (a 2.8%, (b 4.8%, and (c 10% of the blade span. Several pressure taps on the top plate above the blades were connected to pressure gauges. By a CCD camera the PIV system recorded the velocity field around the leading edge zone including the five cooling holes. The flow distributions both in the tip clearance and in the passage were revealed, and the influence of the inlet velocity was determined. In this work, the tip flow characteristics with and without film cooling were investigated. The effects of different global blowing ratios of M=0.5, 1.0, 1.3 and 2.5 were established. It was found that decreasing the rim width resulted in a lower mass flow rate of the leakage flow, and the pressure distributions from the leading edge to the trailing edge showed a linearly increasing trend. It was also found that if the inlet velocity was less than 1.5 m/s, the flow field in the passage far away from the suction side appeared as a stagnation zone.

  11. Tip clearance effect on through-flow and performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Young Seok; Kang, Shin Hyoung

    2004-01-01

    Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency

  12. Electron beam fabrication and characterization of high-resolution magnetic force microscopy tips

    Science.gov (United States)

    Rührig, M.; Porthun, S.; Lodder, J. C.; McVitie, S.; Heyderman, L. J.; Johnston, A. B.; Chapman, J. N.

    1996-03-01

    The stray field, magnetic microstructure, and switching behavior of high-resolution electron beam fabricated thin film tips for magnetic force microscopy (MFM) are investigated with different imaging modes in a transmission electron microscope (TEM). As the tiny smooth carbon needles covered with a thermally evaporated magnetic thin film are transparent to the electron energies used in these TEMs it is possible to observe both the external stray field emanating from the tips as well as their internal domain structure. The experiments confirm the basic features of electron beam fabricated thin film tips concluded from various MFM observations using these tips. Only a weak but highly concentrated stray field is observed emanating from the immediate apex region of the tip, consistent with their capability for high resolution. It also supports the negligible perturbation of the magnetization sample due to the tip stray field observed in MFM experiments. Investigation of the magnetization distributions within the tips, as well as preliminary magnetizing experiments, confirm a preferred single domain state of the high aspect ratio tips. To exclude artefacts of the observation techniques both nonmagnetic tips and those supporting different magnetization states are used for comparison.

  13. Technical tips during implantation of selective upper airway stimulation.

    Science.gov (United States)

    Heiser, Clemens; Thaler, Erica; Soose, Ryan J; Woodson, B Tucker; Boon, Maurits

    2018-03-01

    Selective upper airway stimulation is now well-established in the United States and in several European countries, with more than 1,000 patients implanted since U.S. Food and Drug Administration approval in April 2014. The authors herein, all head and neck surgeons, account for approximately one of every five implants completed to date. Several of the authors also provide comprehensive longitudinal care of their patients as dual-specialty sleep medicine physicians. Multi-center, retrospective clinical analysis. More than 300 implants have been evaluated and reviewed in five different implant centers (Germany, United States). This analysis shares tips and techniques from the collective experiences with more than 300 implants, which can help newer implanters learn vicariously both for standard practices in executing routine implants through activation and, importantly, for working through more challenging encounters with anatomy, special patient phenotypes, system testing, and troubleshooting. These tips should help new implanters handle most of the situations arising during implantation and avoid common pitfalls. Laryngoscope, 128:756-762, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  14. A numerical study of crack tip constraint in ductile single crystals

    Science.gov (United States)

    Patil, Swapnil D.; Narasimhan, R.; Mishra, R. K.

    In this work, the effect of crack tip constraint on near-tip stress and deformation fields in a ductile FCC single crystal is studied under mode I, plane strain conditions. To this end, modified boundary layer simulations within crystal plasticity framework are performed, neglecting elastic anisotropy. The first and second terms of the isotropic elastic crack tip field, which are governed by the stress intensity factor K and T-stress, are prescribed as remote boundary conditions and solutions pertaining to different levels of T-stress are generated. It is found that the near-tip deformation field, especially, the development of kink or slip shear bands, is sensitive to the constraint level. The stress distribution and the size and shape of the plastic zone near the crack tip are also strongly influenced by the level of T-stress, with progressive loss of crack tip constraint occurring as T-stress becomes more negative. A family of near-tip fields is obtained which are characterized by two terms (such as K and T or J and a constraint parameter Q) as in isotropic plastic solids.

  15. Fabrication of tungsten tip for scanning tunneling microscope by the lever principle

    International Nuclear Information System (INIS)

    Wang Yang; Wang Huabin; Chinese Academy of Sciences, Beijing; Gong Jinlong; Zhu Dezhang

    2007-01-01

    A novel experimental setup was designed to fabricate tungsten tips for scanning tunneling microscope (STM), based on simple mechanical lever principle. The equipment can quickly separate the tip from electrolyte to avoid the further etching of the fine-shaped tungsten tip. The setup is advantageous for its simplicity over complex electronic control systems. The use result in scanning electron microscope demonstrates that the radius of the tip can reach 50 nm. The tip was applied to scan the surface of highly-oriented pyrolytic graphite, and the results were satisfactory. It is shown that the tip can be used for the scanning of atomically resolved images. (authors)

  16. Investigation of Unsteady Tip Clearance Flow in a Low-Speed One and Half Stage Axial Compressor with LES And PIV

    Science.gov (United States)

    Hah, Chunill; Hathaway, Michael; Katz, Joseph; Tan, David

    2015-01-01

    The primary focus of this paper is to investigate how a rotor's unsteady tip clearance flow structure changes in a low speed one and half stage axial compressor when the rotor tip gap size is increased from 0.5 mm (0.49% of rotor tip blade chord, 2% of blade span) to 2.4 mm (2.34% chord, 4% span) at the design condition are investigated. The changes in unsteady tip clearance flow with the 0.62 % tip gap as the flow rate is reduced to near stall condition are also investigated. A Large Eddy Simulation (LES) is applied to calculate the unsteady flow field at these three flow conditions. Detailed Stereoscopic PIV (SPIV) measurements of the current flow fields were also performed at the Johns Hopkins University in a refractive index-matched test facility which renders the compressor blades and casing optically transparent. With this setup, the unsteady velocity field in the entire flow domain, including the flow inside the tip gap, can be measured. Unsteady tip clearance flow fields from LES are compared with the PIV measurements and both LES and PIV results are used to study changes in tip clearance flow structures. The current study shows that the tip clearance vortex is not a single structure as traditionally perceived. The tip clearance vortex is formed by multiple interlaced vorticities. Therefore, the tip clearance vortex is inherently unsteady. The multiple interlaced vortices never roll up to form a single structure. When phased-averaged, the tip clearance vortex appears as a single structure. When flow rate is reduced with the same tip gap, the tip clearance vortex rolls further upstream and the tip clearance vortex moves further radially inward and away from the suction side of the blade. When the tip gap size is increased at the design flow condition, the overall tip clearance vortex becomes stronger and it stays closer to the blade suction side and the vortex core extends all the way to the exit of the blade passage. Measured and calculated unsteady flow

  17. Tipping elements in the Arctic marine ecosystem.

    Science.gov (United States)

    Duarte, Carlos M; Agustí, Susana; Wassmann, Paul; Arrieta, Jesús M; Alcaraz, Miquel; Coello, Alexandra; Marbà, Núria; Hendriks, Iris E; Holding, Johnna; García-Zarandona, Iñigo; Kritzberg, Emma; Vaqué, Dolors

    2012-02-01

    The Arctic marine ecosystem contains multiple elements that present alternative states. The most obvious of which is an Arctic Ocean largely covered by an ice sheet in summer versus one largely devoid of such cover. Ecosystems under pressure typically shift between such alternative states in an abrupt, rather than smooth manner, with the level of forcing required for shifting this status termed threshold or tipping point. Loss of Arctic ice due to anthropogenic climate change is accelerating, with the extent of Arctic sea ice displaying increased variance at present, a leading indicator of the proximity of a possible tipping point. Reduced ice extent is expected, in turn, to trigger a number of additional tipping elements, physical, chemical, and biological, in motion, with potentially large impacts on the Arctic marine ecosystem.

  18. Sports Dehydration Safety Tips

    Science.gov (United States)

    Sports Dehydration Safety Tips Everything you need to know to keep your kids safe from dehydration when playing sports. To keep kids in top ... to stay hydrated by drinking plenty of fluids. Dehydration occurs when a body loses more water than ...

  19. Anisotropic Adhesion Properties of Triangular-Tip-Shaped Micropillars

    KAUST Repository

    Kwak, Moon Kyu

    2011-06-01

    Directional dry adhesive microstructures consisting of high-density triangular-tip-shaped micropillars are described. The wide-tip structures allow for unique directional shear adhesion properties with respect to the peeling direction, along with relatively high normal adhesion. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Anisotropic Adhesion Properties of Triangular-Tip-Shaped Micropillars

    KAUST Repository

    Kwak, Moon Kyu; Jeong, Hoon Eui; Bae, Won Gyu; Jung, Ho-Sup; Suh, Kahp Y.

    2011-01-01

    Directional dry adhesive microstructures consisting of high-density triangular-tip-shaped micropillars are described. The wide-tip structures allow for unique directional shear adhesion properties with respect to the peeling direction, along with relatively high normal adhesion. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Defining tipping points for social-ecological systems scholarship—an interdisciplinary literature review

    Science.gov (United States)

    Milkoreit, Manjana; Hodbod, Jennifer; Baggio, Jacopo; Benessaiah, Karina; Calderón-Contreras, Rafael; Donges, Jonathan F.; Mathias, Jean-Denis; Rocha, Juan Carlos; Schoon, Michael; Werners, Saskia E.

    2018-03-01

    The term tipping point has experienced explosive popularity across multiple disciplines over the last decade. Research on social-ecological systems (SES) has contributed to the growth and diversity of the term’s use. The diverse uses of the term obscure potential differences between tipping behavior in natural and social systems, and issues of causality across natural and social system components in SES. This paper aims to create the foundation for a discussion within the SES research community about the appropriate use of the term tipping point, especially the relatively novel term ‘social tipping point.’ We review existing literature on tipping points and similar concepts (e.g. regime shifts, critical transitions) across all spheres of science published between 1960 and 2016 with a special focus on a recent and still small body of work on social tipping points. We combine quantitative and qualitative analyses in a bibliometric approach, rooted in an expert elicitation process. We find that the term tipping point became popular after the year 2000—long after the terms regime shift and critical transition—across all spheres of science. We identify 23 distinct features of tipping point definitions and their prevalence across disciplines, but find no clear taxonomy of discipline-specific definitions. Building on the most frequently used features, we propose definitions for tipping points in general and social tipping points in SES in particular.

  2. Are TIPS Stent-Grafts a Contraindication for Future Liver Transplantation?

    International Nuclear Information System (INIS)

    Maleux, Geert; Pirenne, Jacques; Vaninbroukx, Johan; Aerts, Raymond; Nevens, Frederik

    2004-01-01

    Our purpose was to assess the feasibility of orthotopic liver transplantation (OLT) in patients priorly having undergone transjugular intrahepatic portosystemic shunt (TIPS) with an expanded tetrafluoroethylene (e-PTFE)-covered endoprosthesis. In 48 patients an e- PTFE-covered endoprosthesis was inserted to treat severe complications of portal hypertension. In 36 patients the endoprosthesis was inserted during TIPS creation (de novo TIPS); in the other 12 patients the endoprosthesis was placed to repermeabilize the previously created, but occluded bare stent (revision TIPS). Eight of them (5 de novo and 3 revision cases) later underwent an OLT. The hospital records of these patients were reviewed from initial admission, through TIPS, the pre-OLT period, and OLT to current postoperative status. Five de novo and 3 revision cases underwent OLT 4-279 days (mean delay: 80.8 days) after TIPS procedure. All OLT's were performed under veno-venous bypass surgery. De visu surgical inspection confirmed correct positioning of the fully patent stent graft, starting in the portal vein and ending at the junction of the hepatic vein to the inferior caval vein. No surgical difficulty was observed during proximal or distal clamping or during resection of the diseased liver. Correctly positioned e-PTFE-covered nitinol endoprostheses do not interfere with a later OLT and may not be considered as a contraindication in patients who need a TIPS as a bridge to OLT

  3. 29 CFR 531.59 - The tip wage credit.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false The tip wage credit. 531.59 Section 531.59 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR REGULATIONS WAGE PAYMENTS UNDER THE FAIR LABOR STANDARDS ACT OF 1938 Interpretations Payment of Wages to Tipped Employees...

  4. Tip loss correction for actuator / Navier Stokes computations

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Sørensen, Jens Nørkær; Mikkelsen, Robert Flemming

    2004-01-01

    The new tip loss correction, initially developed for ID BEM computations [1], is now extended to 2D Actuator Disc / Navier-Stokes (AD/NS) computations and 3D Actuator Line / Navier-Stokes (AL/NS) computations. As shown in the paper, the tip loss correction is an important and necessary step...

  5. Characterization of SCC crack tip and hydrogen distribution in alloy 600

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Katsuhiko; Nakajima, Nobuo; Fukuya, Koji [Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan); Hatano, Yuji [Toyama Univ. (Japan)

    2001-09-01

    In order to identify the mechanism of primary water stress corrosion cracking (SCC), direct observations of SCC crack tip microstructure and hydrogen distribution in alloy 600 were carried out. A new technique has been developed to prepare electron transparent foils including the crack tip using focused-ion beam (FIB) micro-processing technique. Cr-rich oxide and metal-Ni phase were identified in the crack tip and grain boundary ahead of the crack. >From the fact that similar microstructure was observed in the surface oxide layer, it is suggested that the oxidation mechanism is identical at the crack tip region and the surface. It became clear that the crack tip region and the oxidized grain boundary don't work as strong trapping sites of solute hydrogen under unloaded condition, because a homogeneous hydrogen distribution around the crack tip region was detected by tritium microautoradiography. (author)

  6. Regulation of H+ Extrusion and Cytoplasmic pH in Maize Root Tips Acclimated to a Low-Oxygen Environment.

    Science.gov (United States)

    Xia, J. H.; Roberts, JKM.

    1996-05-01

    We tested the hypothesis that H+ extrusion contributes to cytoplasmic pH regulation and tolerance of anoxia in maize (Zea mays) root tips. We studied root tips of whole seedlings that were acclimated to a low-oxygen environment by pretreatment in 3% (v/v) O2. Acclimated root tips characteristically regulate cytoplasmic pH near neutrality and survive prolonged anoxia, whereas nonacclimated tips undergo severe cytoplasmic acidosis and die much more quickly. We show that the plasma membrane H+-ATPase can operate under anoxia and that net H+ extrusion increases when cytoplasmic pH falls. However, at an external pH near 6.0, H+ extrusion contributes little to cytoplasmic pH regulation. At more acidic external pH values, net H+ flux into root tips increases dramatically, leading to a decrease in cytoplasmic pH and reduced tolerance of anoxia. We present evidence that, under these conditions, H+ pumps are activated to partly offset acidosis due to H+ influx and, thereby, contribute to cytoplasmic pH regulation and tolerance of anoxia. The regulation of H+ extrusion under anoxia is discussed with respect to the acclimation response and mechanisms of intracellular pH regulation in aerobic plant cells.

  7. Thermoelectric voltage at a nanometer-scale heated tip point contact

    International Nuclear Information System (INIS)

    Fletcher, Patrick C; Lee, Byeonghee; King, William P

    2012-01-01

    We report thermoelectric voltage measurements between the platinum-coated tip of a heated atomic force microscope (AFM) cantilever and a gold-coated substrate. The cantilevers have an integrated heater–thermometer element made from doped single crystal silicon, and a platinum tip. The voltage can be measured at the tip, independent from the cantilever heating. We used the thermocouple junction between the platinum tip and the gold substrate to measure thermoelectric voltage during heating. Experiments used either sample-side or tip-side heating, over the temperature range 25–275 °C. The tip–substrate contact is ∼4 nm in diameter and its average measured Seebeck coefficient is 3.4 μV K −1 . The thermoelectric voltage is used to determine tip–substrate interface temperature when the substrate is either glass or quartz. When the non-dimensional cantilever heater temperature is 1, the tip–substrate interface temperature is 0.593 on glass and 0.125 on quartz. Thermal contact resistance between the tip and the substrate heavily influences the tip–substrate interface temperature. Measurements agree well with modeling when the tip–substrate interface contact resistance is 10 8 K W −1 . (paper)

  8. Fracture mechanics by three-dimensional crack-tip synchrotron X-ray microscopy.

    Science.gov (United States)

    Withers, P J

    2015-03-06

    To better understand the relationship between the nucleation and growth of defects and the local stresses and phase changes that cause them, we need both imaging and stress mapping. Here, we explore how this can be achieved by bringing together synchrotron X-ray diffraction and tomographic imaging. Conventionally, these are undertaken on separate synchrotron beamlines; however, instruments capable of both imaging and diffraction are beginning to emerge, such as ID15 at the European Synchrotron Radiation Facility and JEEP at the Diamond Light Source. This review explores the concept of three-dimensional crack-tip X-ray microscopy, bringing them together to probe the crack-tip behaviour under realistic environmental and loading conditions and to extract quantitative fracture mechanics information about the local crack-tip environment. X-ray diffraction provides information about the crack-tip stress field, phase transformations, plastic zone and crack-face tractions and forces. Time-lapse CT, besides providing information about the three-dimensional nature of the crack and its local growth rate, can also provide information as to the activation of extrinsic toughening mechanisms such as crack deflection, crack-tip zone shielding, crack bridging and crack closure. It is shown how crack-tip microscopy allows a quantitative measure of the crack-tip driving force via the stress intensity factor or the crack-tip opening displacement. Finally, further opportunities for synchrotron X-ray microscopy are explored.

  9. Examination of parameters affecting overload fracture behavior of flaw-tip hydrides in Zr-2.5Nb pressure tubes in Candu reactors

    International Nuclear Information System (INIS)

    Cui, J.; Shek, G.K.; Wang, Z.R.

    2007-01-01

    Service-induced flaws in Zr-2.5Nb alloy pressure tubes in Candu (Canada Deuterium Uranium Reactors) nuclear reactors are susceptible to a crack initiation and growth mechanism known as Delayed Hydride Cracking (DHC), which is a repetitive process that involves hydrogen diffusion, hydride precipitation, growth and fracture of a hydride region at the flaw-tip under a constant load. Crack initiation may also occur under another loading condition when the hydride region is subjected to an overload. An overload occurs when the hydride region at the flaw tip is loaded to a stress higher than that at which this region is formed such as when the reactor experiences a transient pressure higher than the normal operating pressure where the hydride region is formed. Flaw disposition requires justification that the hydride region overload will not fracture the hydride region, and initiate DHC. In this work, monotonically increasing load experiments were performed on unirradiated Zr-2.5Nb pressure tube specimens containing simulated debris frets (V-notch) and bearing pad frets (BPF, U-shape notch) to examine overload fracture behavior of flaw-tip hydrides formed under hydride ratcheting conditions. Hydride cracking in the overload tests was detected by the acoustic emission technique and confirmed by post-test metallurgical examination. Test results indicate that the resistance to overload fracture is affected by a number of parameters including hydride formation stress, flaw shape (V-notch vs. BPF) and flaw radius (0.015 mm vs. 0.1 mm). The notch-tip hydride morphologies were examined by optical microscopy and scanning electron microscopy (SEM) which show that they are affected by the hydride formation conditions, resulting in different overload fracture resistance. Finite element stress analyses were also performed to obtain flaw-tip stress distributions for interpretation of the test results. (authors)

  10. Tip moth parasitoids and pesticides: Are they compatible?

    Science.gov (United States)

    Kenneth W. McCravy; Mark J. Dalusky; C. Wayne Berisford

    1999-01-01

    Effects of herbicide and insecticide applications on parasitism of the Nantucket pine tip moth, Rhyacionia frustrana (Comstock) were examined in 2-yr-old loblolly pine (Pinus taeda L.) plantations in Georgia. Total parasitism rates varied significantly among tip moth generations, but there were no differences in parasitism rates between herbicide-treated and untreated...

  11. Characteristics of Handwriting of People With Cerebellar Ataxia: Three-Dimensional Movement Analysis of the Pen Tip, Finger, and Wrist.

    Science.gov (United States)

    Fujisawa, Yuhki; Okajima, Yasutomo

    2015-11-01

    There are several functional tests for evaluating manual performance; however, quantitative manual tests for ataxia, especially those for evaluating handwriting, are limited. This study aimed to investigate the characteristics of cerebellar ataxia by analyzing handwriting, with a special emphasis on correlation between the movement of the pen tip and the movement of the finger or wrist. This was an observational study. Eleven people who were right-handed and had cerebellar ataxia and 17 people to serve as controls were recruited. The Scale for the Assessment and Rating of Ataxia was used to grade the severity of ataxia. Handwriting movements of both hands were analyzed. The time required for writing a character, the variability of individual handwriting, and the correlation between the movement of the pen tip and the movement of the finger or wrist were evaluated for participants with ataxia and control participants. The writing time was longer and the velocity profile and shape of the track of movement of the pen tip were more variable in participants with ataxia than in control participants. For participants with ataxia, the direction of movement of the pen tip deviated more from that of the finger or wrist, and the shape of the track of movement of the pen tip differed more from that of the finger or wrist. The severity of upper extremity ataxia measured with the Scale for the Assessment and Rating of Ataxia was mostly correlated with the variability parameters. Furthermore, it was correlated with the directional deviation of the trajectory of movement of the pen tip from that of the finger and with increased dissimilarity of the shapes of the tracks. The results may have been influenced by the scale and parameters used to measure movement. Ataxic handwriting with increased movement noise is characterized by irregular pen tip movements unconstrained by the finger or wrist. The severity of ataxia is correlated with these unconstrained movements. © 2015 American

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... This can result in significant challenges in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This page ...

  13. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  14. Microfabricated microneedle with porous tip for drug delivery

    Science.gov (United States)

    Ji, Jing; Tay, Francis E. H.; Miao, Jianmin; Iliescu, Ciprian

    2006-05-01

    This paper presents a novel approach to fabrication of a silicon microneedle array with porous tips. Dry etching technology with SF6/O2 gas by STS's inductively coupled plasma (ICP) etch tool was used to achieve the pyramidal needle structure. A thin silicon nitride layer was deposited after a thick photoresist layer was coated and reflowed at 120 °C. The silicon nitride layer and residual photoresist on the tips of the pyramidal structures were removed using reactive ion etching (RIE). Electrochemical etching in MeCN/HF was carried out to generate porous silicon on the tips of the microneedles. The fabricated microneedle array has potential applications in drug delivery, since the porous tips can be loaded with a high molecular weight drug. Analytic solutions to the critical loadings of the fabricated microneedle structure are also presented. The variations of the square cross-section were expressed as a function of the axial coordinate to analyze the bending normal stress and critical buckling loading. This analytic method can also be used for other microneedle structures with different cross-sections.

  15. Numerical study on tip clearance effect on performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Shin Kyoung

    2003-01-01

    Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASCflow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected performance equally, while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully

  16. Design of characteristic parameters for controlling tungsten tip profile during electrochemical etching

    Energy Technology Data Exchange (ETDEWEB)

    Le Duy Cuong; Duong, Thanh Hung; Kim, Huyn Chul [Inje University, Gimhae (Korea, Republic of)

    2014-05-15

    Micro/nano-scale tungsten tips fabricated by electrochemical etching have many diverse industrial applications. The characteristic parameters of the tungsten tip profile include apex radius, taper angle, and aspect ratio. These parameters are governed by many factors including applied voltage, concentration of the electrolyte (potassium hydroxide) solution, and diameter of the inner gold ring. However, a systematic investigation with the aim of determining the best conditions for fabricating micro/nano-scale tips with desired profiles has not been carried out yet. This study is aimed at obtaining controllable tungsten tip -particularly with respect to the radius of curvature and aspect ratio of tips (taper angle)-by altering the experimental conditions. A series of experiments were executed and the results were aggregated and analyzed using response surface methodology in order to identify the relationships between the tungsten tip characteristics and input parameters. The method proposed herein would prove to be suitable for a variety of applications in industries that require tungsten tips with a specific profile.

  17. Design of characteristic parameters for controlling tungsten tip profile during electrochemical etching

    International Nuclear Information System (INIS)

    Le Duy Cuong; Duong, Thanh Hung; Kim, Huyn Chul

    2014-01-01

    Micro/nano-scale tungsten tips fabricated by electrochemical etching have many diverse industrial applications. The characteristic parameters of the tungsten tip profile include apex radius, taper angle, and aspect ratio. These parameters are governed by many factors including applied voltage, concentration of the electrolyte (potassium hydroxide) solution, and diameter of the inner gold ring. However, a systematic investigation with the aim of determining the best conditions for fabricating micro/nano-scale tips with desired profiles has not been carried out yet. This study is aimed at obtaining controllable tungsten tip -particularly with respect to the radius of curvature and aspect ratio of tips (taper angle)-by altering the experimental conditions. A series of experiments were executed and the results were aggregated and analyzed using response surface methodology in order to identify the relationships between the tungsten tip characteristics and input parameters. The method proposed herein would prove to be suitable for a variety of applications in industries that require tungsten tips with a specific profile

  18. High resolution magnetic force microscopy using focused ion beam modified tips

    NARCIS (Netherlands)

    Phillips, G.N.; Siekman, Martin Herman; Abelmann, Leon; Lodder, J.C.

    2002-01-01

    Atomic force microscope tips coated by the thermal evaporation of a magnetic 30 nm thick Co film have been modified by focused ion beam milling with Ga+ ions to produce tips suitable for magnetic force microscopy. Such tips possess a planar magnetic element with high magnetic shape anisotropy, an

  19. Scaled multiple holes suction tip for microneurosurgery; Technical note

    Directory of Open Access Journals (Sweden)

    Abdolkarim Rahmanian, Associate Professor of Neurosurgery

    2017-12-01

    Conclusion: The new suction tip permits easy and precise adjustment of suction power in microneurosirgical operations. Our scaled 3 and 4-hole suction tip is a simple and useful device for controlling the suction power during the microneurosurgeical procedures.

  20. Pipette tip with integrated electrodes for gene electrotransfer of cells in suspension: a feasibility study in CHO cells

    International Nuclear Information System (INIS)

    Rebersek, Matej; Kanduser, Masa; Miklavcic, Damijan

    2011-01-01

    Gene electrotransfer is a non-viral gene delivery method that requires successful electroporation for DNA delivery into the cells. Changing the direction of the electric field during the pulse application improves the efficacy of gene delivery. In our study, we tested a pipette tip with integrated electrodes that enables changing the direction of the electric field for electroporation of cell suspension for gene electrotransfer. A new pipette tip consists of four cylindrical rod electrodes that allow the application of electric pulses in different electric field directions. The experiments were performed on cell suspension of CHO cells in phosphate buffer. Plasmid DNA encoding for green fluorescent protein (GFP) was used and the efficiency of gene electrotransfer was determined by counting cells expressing GFP 24 h after the experiment. Experimental results showed that the percentage of cells expressing GFP increased when the electric field orientation was changed during the application. The GFP expression was almost two times higher when the pulses were applied in orthogonal directions in comparison with single direction, while cell viability was not significantly affected. We can conclude that results obtained with the described pipette tip are comparable to previously published results on gene electrotransfer using similar electrode geometry and electric pulse parameters. The tested pipette tip, however, allows work with small volumes/samples and requires less cell manipulation

  1. Quantitative analysis of tip-sample interaction in non-contact scanning force spectroscopy

    International Nuclear Information System (INIS)

    Palacios-Lidon, Elisa; Colchero, Jaime

    2006-01-01

    Quantitative characterization of tip-sample interaction in scanning force microscopy is fundamental for optimum image acquisition as well as data interpretation. In this work we discuss how to characterize the electrostatic and van der Waals contribution to tip-sample interaction in non-contact scanning force microscopy precisely. The spectroscopic technique presented is based on the simultaneous measurement of cantilever deflection, oscillation amplitude and frequency shift as a function of tip-sample voltage and tip-sample distance as well as on advanced data processing. Data are acquired at a fixed lateral position as interaction images, with the bias voltage as fast scan, and tip-sample distance as slow scan. Due to the quadratic dependence of the electrostatic interaction with tip-sample voltage the van der Waals force can be separated from the electrostatic force. Using appropriate data processing, the van der Waals interaction, the capacitance and the contact potential can be determined as a function of tip-sample distance. The measurement of resonance frequency shift yields very high signal to noise ratio and the absolute calibration of the measured quantities, while the acquisition of cantilever deflection allows the determination of the tip-sample distance

  2. Stress induced martensite at the crack tip in NiTi alloys during fatigue loading

    Directory of Open Access Journals (Sweden)

    E. Sgambitterra

    2014-10-01

    Full Text Available Crack tip stress-induced phase transformation mechanisms in nickel-titanium alloys (NiTi were analyzed by Digital Image Correlation (DIC, under fatigue loads. In particular, Single Edge Crack (SEC specimens, obtained from a commercial pseudoelastic NiTi sheet, and an ad-hoc experimental setup were used, for direct measurements of the near crack tip displacement field by the DIC technique. Furthermore, a fitting procedure was developed to calculate the mode I Stress Intensity Factor (SIF, starting from the measured displacement field. Finally, cyclic tensile tests were performed at different operating temperature, in the range 298-338 K, and the evolution of the SIF was studied, which revealed a marked temperature dependence.

  3. Evaluation of the safety and efficiency of novel metallic ultrasonic scaler tip on titanium surfaces.

    Science.gov (United States)

    Baek, Seung-Ho; Shon, Won-Jun; Bae, Kwang-Shik; Kum, Kee-Yeon; Lee, Woo-Cheol; Park, Young-Seok

    2012-11-01

    To evaluate the safety and efficiency of novel ultrasonic scaler tips, conventional stainless-steel tips, and plastic tips on titanium surfaces. Mechanical instrumentation was carried out using conventional ultrasonic scalers (EMS, Nyon, Switzerland) with novel metallic implant tip (BS), a plastic-headed tip (ES), a plastic tip (PS) and a conventional stainless-steel tip (CS) on 10 polished commercially pure titanium disks (Grade II) per group. Arithmetic mean roughness (R(a) ) and maximum height roughness (R(y) ) of titanium samples were measured and dissipated power of the scaler tip in the tip-surface junction was estimated to investigate the scaling efficiency. The instrumented surface morphology of samples was viewed with a scanning electron microscope (SEM) and surface profile of the each sample was investigated using contact mode with a commercial atomic force microscope (AFM). There were no significant differences in surface roughness (R(a) and R(y) ) among BS, ES, and PS group. However, CS group showed significant higher surface roughness (R(a) and R(y) ). The efficiency of CS tip is twice as much higher than that of BS tip, the efficiency of BS tip is 20 times higher than that of PS tip, and the efficiency of BS tip is 90 times higher than that of ES tip. Novel metallic copper alloy ultrasonic scaler tips may minimally influence the titanium surface, similar to plastic tip. Therefore, they can be a suitable instrument for implant maintenance therapy. © 2011 John Wiley & Sons A/S.

  4. Tip-Based Nanofabrication for Scalable Manufacturing

    Directory of Open Access Journals (Sweden)

    Huan Hu

    2017-03-01

    Full Text Available Tip-based nanofabrication (TBN is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. In this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  5. Tip-Based Nanofabrication for Scalable Manufacturing

    International Nuclear Information System (INIS)

    Hu, Huan; Somnath, Suhas

    2017-01-01

    Tip-based nanofabrication (TBN) is a family of emerging nanofabrication techniques that use a nanometer scale tip to fabricate nanostructures. Here in this review, we first introduce the history of the TBN and the technology development. We then briefly review various TBN techniques that use different physical or chemical mechanisms to fabricate features and discuss some of the state-of-the-art techniques. Subsequently, we focus on those TBN methods that have demonstrated potential to scale up the manufacturing throughput. Finally, we discuss several research directions that are essential for making TBN a scalable nano-manufacturing technology.

  6. Tip-modified Propellers

    DEFF Research Database (Denmark)

    Andersen, Poul

    1999-01-01

    The paper deals with tip-modified propellers and the methods which, over a period of two decades, have been applied to develop such propellers. The development is driven by the urge to increase the efficiency of propellers and can be seen as analogous to fitting end plates and winglets to aircraft...... propeller, have efficiency increases of a reasonable magnitude in both open-water and behind-ship conditions....

  7. Evaluation of dual-tip micromanometers during 21-day implantation in goats

    Science.gov (United States)

    Reister, C. A.; Koenig, S. C.; Schaub, J. D.; Ewert, D. L.; Swope, R. D.; Latham, R. D.; Fanton, J. W.; Convertino, V. A. (Principal Investigator)

    1998-01-01

    Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

  8. Management of the droopy tip: a comparison of three alar cartilage-modifying techniques.

    Science.gov (United States)

    Foda, Hossam M T

    2003-10-01

    The droopy tip is a common nasal deformity in which the tip is inferiorly rotated. Five hundred consecutive rhinoplasty cases were studied to assess the incidence and causes of the droopy tip deformity and to evaluate the role of three alar cartilage-modifying techniques--lateral crural steal, lateral crural overlay, and tongue in groove--in correcting such a deformity. The external rhinoplasty approach was used in all cases. Only one of the three alar cartilage-modifying techniques was used in each case, and the degree of tip rotation and projection was measured both preoperatively and postoperatively. The incidence of droopy tip was 72 percent, and the use of an alar cartilage-modifying technique was required in 85 percent of these cases to achieve the desired degree of rotation. The main causes of droopy tip included inferiorly oriented alar cartilages (85 percent), overdeveloped scrolls of upper lateral cartilages (73 percent), high anterior septal angle (65 percent), and thick skin of the nasal lobule (56 percent). The lateral crural steal technique increased nasal tip rotation and projection, the lateral crural overlay technique increased tip rotation and decreased tip projection, and the tongue-in-groove technique increased tip rotation without significantly changing the amount of projection. The lateral crural overlay technique resulted in the highest degrees of rotation, followed by the lateral crural steal and finally the tongue-in-groove technique. According to these results, the lateral crural steal technique is best indicated in cases with droopy underprojected nasal tip, the lateral crural overlay technique in cases of droopy overprojected nasal tip, and the tongue-in-groove technique in cases where the droopy nasal tip is associated with an adequate amount of projection.

  9. THE ROLE OF TIPPING IN REDUCING LABOUR COSTS: CASE OF SECTOR RETAIL PETROLEUM PRODUCTS

    Directory of Open Access Journals (Sweden)

    Andrej Raspor

    2014-05-01

    Full Text Available The purpose of this paper was to determine whether tipping could reduce labour costs in the petroleum products retail sector. The research we present was designed on the basis of survey results gathered from Slovenian petrol stations in 2009 and 2010. We have identified the following factors in the tipping process: job satisfaction, flexibility, service quality, satisfaction, motivation and the factor of receiving tips. The analysis showed correlation between methods used to increase the value of tips and better service quality, increased financial and numerical flexibility, motivation, satisfaction upon receipt of tips and the method used to increase the value of tips. In order to decrease labour costs we propose that the management take control of tipping and integrates tips into the reward system. Also, the employees should be made aware about how tipping improves service and increases their income.

  10. Energy Savers: Cool Summer Tips

    International Nuclear Information System (INIS)

    Miller, M.

    2001-01-01

    A tri-fold brochure addressing energy-saving tips for homeowners ranging from low- or no-cost suggestions to higher cost suggestions for longer-term savings. Cooling, windows, weatherizing, and landscaping are addressed

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  12. Sub-harmonic broadband humps and tip noise in low-speed ring fans.

    Science.gov (United States)

    Moreau, Stéphane; Sanjose, Marlène

    2016-01-01

    A joint experimental and numerical study has been achieved on a low-speed axial ring fan in clean inflow. Experimental evidence shows large periodic broadband humps at lower frequencies than the blade passing frequencies and harmonics even at design conditions. These sub-harmonic humps are also found to be sensitive to the fan process and consequently to its tip geometry. Softer fans yield more intense humps more shifted to lower frequencies with respect to the fan harmonics. Unsteady turbulent flow simulations of this ring fan mounted on a test plenum have been achieved by four different methods that have been validated by comparing with overall performances and detailed hot-wire velocity measurements in the wake. Noise predictions are either obtained directly or are obtained through Ffowcs Williams and Hawkings' analogy, and compared with narrowband and third-octave power spectra. All unsteady simulations correctly capture the low flow rates, the coherent vortex dynamics in the tip clearance and consequently the noise radiation dominated by the tip noise in the low- to mid-frequency range. Yet, only the scale-adaptive simulation and the lattice Boltzmann method simulations which can describe most of the turbulent structures accurately provide the proper spectral shape and levels, and consequently the overall sound power level.

  13. 21 CFR 890.3790 - Cane, crutch, and walker tips and pads.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cane, crutch, and walker tips and pads. 890.3790 Section 890.3790 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., crutch, and walker tips and pads. (a) Identification. Cane, crutch, and walker tips and pads are rubber...

  14. Dual-tip magnetic force microscopy with suppressed influence on magnetically soft samples

    International Nuclear Information System (INIS)

    Precner, Marián; Fedor, Ján; Šoltýs, Ján; Cambel, Vladimír

    2015-01-01

    Standard magnetic force microscopy (MFM) is considered as a powerful tool used for magnetic field imaging at nanoscale. The method consists of two passes realized by the magnetic tip. Within the first one, the topography pass, the magnetic tip directly touches the magnetic sample. Such contact perturbs the magnetization of the sample explored. To avoid the sample touching the magnetic tip, we present a new approach to magnetic field scanning by segregating the topological and magnetic scans with two different tips located on a cut cantilever. The approach minimizes the disturbance of sample magnetization, which could be a major problem in conventional MFM images of soft magnetic samples. By cutting the cantilever in half using the focused ion beam technique, we create one sensor with two different tips—one tip is magnetized, and the other one is left non-magnetized. The non-magnetized tip is used for topography and the magnetized one for the magnetic field imaging. The method developed we call dual-tip magnetic force microscopy (DT-MFM). We describe in detail the dual-tip fabrication process. In the experiments, we show that the DT-MFM method reduces significantly the perturbations of the magnetic tip as compared to the standard MFM method. The present technique can be used to investigate microscopic magnetic domain structures in a variety of magnetic samples and is relevant in a wide range of applications, e.g., data storage and biomedicine. (paper)

  15. Creative accomplishment of continuous TIP motor torque monitoring system in BWR plant

    International Nuclear Information System (INIS)

    Sun, C.H.; Li, I.N.; Liu, C.S.

    1986-01-01

    The Traveling In-core Probe (TIP) system is designed so delicate that the routine preventive maintenance - torque measurement is required to keep system operating properly. Normally, the torque measurement is performed by manually rotating torque wrench on the local TIP drive mechanism or using wattmeter during automatic operation. Whenever, either torque wrench or wattmeter measurement is performed, the high radiation exposure to maintenance personnel and mass manpower is expected. Because of this reason Taipower has developed a continuous TIP motor torque monitoring system to save manpower and minimize radiation exposure to maintenance personnel. This methods of TIP motor torque measurement will also predict TIP guide tube deterioration. (author)

  16. Predicting mountain lion activity using radiocollars equipped with mercury tip-sensors

    Science.gov (United States)

    Janis, Michael W.; Clark, Joseph D.; Johnson, Craig

    1999-01-01

    Radiotelemetry collars with tip-sensors have long been used to monitor wildlife activity. However, comparatively few researchers have tested the reliability of the technique on the species being studied. To evaluate the efficacy of using tip-sensors to assess mountain lion (Puma concolor) activity, we radiocollared 2 hand-reared mountain lions and simultaneously recorded their behavior and the associated telemetry signal characteristics. We noted both the number of pulse-rate changes and the percentage of time the transmitter emitted a fast pulse rate (i.e., head up) within sampling intervals ranging from 1-5 minutes. Based on 27 hours of observations, we were able to correctly distinguish between active and inactive behaviors >93% of the time using a logistic regression model. We present several models to predict activity of mountain lions; the selection of which to us would depend on study objectives and logistics. Our results indicate that field protocols that use only pulse-rate changes to indicate activity can lead to significant classification errors.

  17. Tips to Prevent Mosquito Bites

    Science.gov (United States)

    ... discourage mosquitoes, ticks and other biting insects from landing on you. Here are tips for other preventive ... CDC Mosquito Control Methods - NPIC Exit Top of Page Contact Us to ask a question, provide feedback, ...

  18. Robust procedure for creating and characterizing the atomic structure of scanning tunneling microscope tips.

    Science.gov (United States)

    Tewari, Sumit; Bastiaans, Koen M; Allan, Milan P; van Ruitenbeek, Jan M

    2017-01-01

    Scanning tunneling microscopes (STM) are used extensively for studying and manipulating matter at the atomic scale. In spite of the critical role of the STM tip, procedures for controlling the atomic-scale shape of STM tips have not been rigorously justified. Here, we present a method for preparing tips in situ while ensuring the crystalline structure and a reproducibly prepared tip structure up to the second atomic layer. We demonstrate a controlled evolution of such tips starting from undefined tip shapes.

  19. Kajian Gaya Interior Pada Restoran Tip Top di Kota Medan

    OpenAIRE

    Kevin

    2016-01-01

    The purpose of this study was to identify / determine the style of interior design that is applied to the Tip Top Restaurant in Medan as well as the public perception of the interior arrangement of Tip Top Restaurant in Medan by using qualitative and quantitative research methods. Qualitative research methods now that the observation / observation, observation of interior elements Tip Top restaurant is analyzed based on the criteria of interior design, this is done in order to ...

  20. Comparison of actual vacuum pressures at the end of 3 phacoemulsification tips in swine eyes.

    Science.gov (United States)

    Park, Sang Hoon; Choi, Chul Young; Kim, Joon Mo; Chang, Hae Ran; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon; Kim, Jae Chan

    2009-05-01

    To compare the actual vacuum pressure at the end of an aspiration bypass system (ABS) phaco tip and a conventional tip in conditions similar to those during human cataract surgery. Kangbuk Samsung Hospital, Seoul, Korea. A 4.0 mm diameter rubber eraser ball was inserted in a phacoemulsified swine eye and engaged to a phaco tip. With a vacuum pressure of 300 mm Hg, the eraser ball was pulled in the opposite direction with the phaco tip. The pulling power separating the eraser ball from the phaco tip was measured using the volume of water dripped into a container connected to the eraser ball. Measurements were taken with an Infiniti ABS tip and 2 conventional tips: Sovereign (conventional tip S) and Infiniti (conventional tip I). Measurements were taken alternatively at random in the same eye. The mean pulling power was 17.35 mL +/- 5.01 (SD) with conventional tip S and 16.85 +/- 4.45 mL with conventional tip I. The mean pulling power of the ABS tip was 13.35 +/- 4.32 mL, which was a mean 20.8% lower than that of conventional tip I (P = .016) and 23.1% lower than that of conventional tip S (P = .010). The actual vacuum pressure of the phaco tip was significantly influenced by the presence of the ABS hole. To compensate for the decrease in actual vacuum pressure, surgeons should be aware of the characteristics of the ABS tip being used and change the standard settings accordingly.

  1. Mitigation of tip vortex cavitation by means of air injection on a Kaplan turbine scale model

    International Nuclear Information System (INIS)

    Rivetti, A; Angulo, M; Lucino, C; Liscia, S

    2014-01-01

    Kaplan turbines operating at full-load conditions may undergo excessive vibration, noise and cavitation. In such cases, damage by erosion associated to tip vortex cavitation can be observed at the discharge ring. This phenomenon involves design features such as (1) overhang of guide vanes; (2) blade profile; (3) gap increasing size with blade opening; (4) suction head; (5) operation point; and (6) discharge ring stiffness, among others. Tip vortex cavitation may cause erosion at the discharge ring and draft tube inlet following a wavy pattern, in which the number of vanes can be clearly identified. Injection of pressurized air above the runner blade centerline was tested as a mean to mitigate discharge ring cavitation damage on a scale model. Air entrance was observed by means of a high-speed camera in order to track the air trajectory toward its mergence with the tip vortex cavitation core. Post-processing of acceleration signals shows that the level of vibration and the RSI frequency amplitude decrease proportionally with air flow rate injected. These findings reveal the potential mitigating effect of air injection in preventing cavitation damage and will be useful in further tests to be performed on prototype, aiming at determining the optimum air flow rate, size and distribution of the injectors

  2. Mitigation of tip vortex cavitation by means of air injection on a Kaplan turbine scale model

    Science.gov (United States)

    Rivetti, A.; Angulo, M.; Lucino, C.; Liscia, S.

    2014-03-01

    Kaplan turbines operating at full-load conditions may undergo excessive vibration, noise and cavitation. In such cases, damage by erosion associated to tip vortex cavitation can be observed at the discharge ring. This phenomenon involves design features such as (1) overhang of guide vanes; (2) blade profile; (3) gap increasing size with blade opening; (4) suction head; (5) operation point; and (6) discharge ring stiffness, among others. Tip vortex cavitation may cause erosion at the discharge ring and draft tube inlet following a wavy pattern, in which the number of vanes can be clearly identified. Injection of pressurized air above the runner blade centerline was tested as a mean to mitigate discharge ring cavitation damage on a scale model. Air entrance was observed by means of a high-speed camera in order to track the air trajectory toward its mergence with the tip vortex cavitation core. Post-processing of acceleration signals shows that the level of vibration and the RSI frequency amplitude decrease proportionally with air flow rate injected. These findings reveal the potential mitigating effect of air injection in preventing cavitation damage and will be useful in further tests to be performed on prototype, aiming at determining the optimum air flow rate, size and distribution of the injectors.

  3. Compound parabolic concentrator optical fiber tip for FRET-based fluorescent sensors

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren

    2015-01-01

    The Compound Parabolic Concentrator (CPC) optical fiber tip shape has been proposed for intensity based fluorescent sensors working on the principle of FRET (Förster Resonance Energy Transfer). A simple numerical Zemax model has been used to optimize the CPC tip geometry for a step-index multimode...... polymer optical fiber for an excitation and emission wavelength of 550 nm and 650nm, respectively. The model suggests an increase of a factor of 1.6 to 4 in the collected fluorescent power for an ideal CPC tip, as compared to the plane-cut fiber tip for fiber lengths between 5 and 45mm...

  4. Valence electron structure and bonding features of RuB2 and OSB2: The empirical electron theory calculations

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    The valence electron structure (VES) of RuB2 and OsB2 were calculated by the empirical electron theory (EET) of solids and molecules and compared with the results derived from the first-principles calculations. The distributions of covalent electrons in different bonds indicate that B-B and B-Me have remarkably covalent bonding characters. Lattice electrons cruising around Me-Me layers are found to have great influences on electronic conductivity and high temperature plasticity. The ultra-high values of elastic constant Cn in the two compounds originate from close-packed covalent bonding along the c axis. Uneven bond strengths and distributions of covalent bonds, especially for B-Afe bonds, yield significant anisotropy. Low ratios of lattice electrons to covalent electrons suggest the intrinsic embrittlement in crystals. The fact that the calculated cohesive energies well agree with experimental results demonstrates the good suitability of the EET calculations in estimating cohesive energy for transition-metal borides.

  5. (Allium cepa) root tip mitosis

    African Journals Online (AJOL)

    Aghomotsegin

    their chemical composition and genotoxic effects on cell reproduction. Two petrochemicals, air ... the chromosomes of the individual cells of the root tip could be a pointer to their ..... Chromosome technique: Theory and. Practice. Butterworths ...

  6. Tip vortices in the actuator line model

    Science.gov (United States)

    Martinez, Luis; Meneveau, Charles

    2017-11-01

    The actuator line model (ALM) is a widely used tool to represent the wind turbine blades in computational fluid dynamics without the need to resolve the full geometry of the blades. The ALM can be optimized to represent the `correct' aerodynamics of the blades by choosing an appropriate smearing length scale ɛ. This appropriate length scale creates a tip vortex which induces a downwash near the tip of the blade. A theoretical frame-work is used to establish a solution to the induced velocity created by a tip vortex as a function of the smearing length scale ɛ. A correction is presented which allows the use of a non-optimal smearing length scale but still provides the downwash which would be induced using the optimal length scale. Thanks to the National Science Foundation (NSF) who provided financial support for this research via Grants IGERT 0801471, IIA-1243482 (the WINDINSPIRE project) and ECCS-1230788.

  7. Aeroelastic behavior of composite rotor blades with swept tips

    Science.gov (United States)

    Yuan, Kuo-An; Friedmann, Peretz P.; Venkatesan, Comandur

    1992-01-01

    This paper presents an analytical study of the aeroelastic behavior of composite rotor blades with straight and swept tips. The blade is modeled by beam type finite elements. A single finite element is used to model the swept tip. The nonlinear equations of motion for the finite element model are derived using Hamilton's principle and based on a moderate deflection theory and accounts for: arbitrary cross-sectional shape, pretwist, generally anisotropic material behavior, transverse shears and out-of-plane warping. Numerical results illustrating the effects of tip sweep, anhedral and composite ply orientation on blade aeroelastic behavior are presented. It is shown that composite ply orientation has a substantial effect on blade stability. At low thrust conditions, certain ply orientations can cause instability in the lag mode. The flap-torsion coupling associated with tip sweep can also induce aeroelastic instability in the blade. This instability can be removed by appropriate ply orientation in the composite construction.

  8. Comparison of heat-testing methodology.

    Science.gov (United States)

    Bierma, Mark M; McClanahan, Scott; Baisden, Michael K; Bowles, Walter R

    2012-08-01

    Patients with irreversible pulpitis occasionally present with a chief complaint of sensitivity to heat. To appropriately diagnose the offending tooth, a variety of techniques have been developed to reproduce this chief complaint. Such techniques cause temperature increases that are potentially damaging to the pulp. Newer electronic instruments control the temperature of a heat-testing tip that is placed directly against a tooth. The aim of this study was to determine which method produced the most consistent and safe temperature increase within the pulp. This consistency facilitates the clinician's ability to differentiate between a normal pulp and irreversible pulpitis. Four operators applied the following methods to each of 4 extracted maxillary premolars (for a total of 16 trials per method): heated gutta-percha, heated ball burnisher, hot water, and a System B unit or Elements unit with a heat-testing tip. Each test was performed for 60 seconds, and the temperatures were recorded via a thermocouple in the pulp chamber. Analysis of the data was performed by using the intraclass correlation coefficient. The least consistent warming was found with hot water. The heat-testing tip also demonstrated greater consistency between operators compared with the other methods. Hot water and the heated ball burnisher caused temperature increases high enough to damage pulp tissue. The Elements unit with a heat-testing tip provides the most consistent warming of the dental pulp. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Impacto de una campaña de mejora de la higiene de manos sobre el consumo de soluciones hidroalcohólicas en un hospital de tercer nivel Impact of a hand hygiene campaign on alcoholic hand rub consumption in a tertiary hospital

    Directory of Open Access Journals (Sweden)

    Trinidad Dierssen-Sotos

    2010-08-01

    Full Text Available Objetivo: Valorar la influencia sobre el consumo de preparados de base alcohólica de una campaña de mejora de la higiene de manos, y más concretamente del desarrollo de talleres prácticos sobre higienización de manos en un hospital de tercer nivel del Servicio Cántabro de Salud. Métodos: Se realizó un estudio ecológico con datos de enero de 2005 a diciembre de 2008. La variable dependiente fue el consumo de preparados de base alcohólica (ml/día. Como variable independiente se utilizó la campaña de mejora de la higiene de manos desarrollada en el Servicio Cántabro de Salud. Para valorar la relación del consumo con la campaña se utilizó un análisis de regresión lineal múltiple. Resultados y conclusiones: Destaca la asociación entre la formación recibida sobre higiene de manos en las unidades de hospitalización y el consumo de preparados de base alcohólica, que mejora al consolidarse la campaña (año 2008 y demuestra un efecto positivo de ésta, en especial de sus aspectos formativos.Objective: To evaluate the influence of a hand hygiene program on consumption of alcoholic hand rub, and specifically the impact of the development of hand washing training in a tertiary hospital belonging to the Cantabrian Health Service in Spain. Methods: We performed an ecological study from January 2005 to December 2008. The dependent variable was consumption of alcoholic hand rub (ml/day. As the independent variable, we used the hand hygiene campaign developed by the Cantabrian Health Service. The relationship between alcoholic hand rub consumption and the campaign was evaluated using multiple linear regression. Results and conclusions: The training received in hand hygiene in hospital wards was associated with consumption of alcoholic hand rub, which improved as the campaign became consolidated (in 2008 and showed a positive effect, particularly its training aspects.

  10. Robust procedure for creating and characterizing the atomic structure of scanning tunneling microscope tips

    Directory of Open Access Journals (Sweden)

    Sumit Tewari

    2017-11-01

    Full Text Available Scanning tunneling microscopes (STM are used extensively for studying and manipulating matter at the atomic scale. In spite of the critical role of the STM tip, procedures for controlling the atomic-scale shape of STM tips have not been rigorously justified. Here, we present a method for preparing tips in situ while ensuring the crystalline structure and a reproducibly prepared tip structure up to the second atomic layer. We demonstrate a controlled evolution of such tips starting from undefined tip shapes.

  11. Computational Investigation of Novel Tip Leakage Mitigation Methods for High Pressure Turbine Blades

    Science.gov (United States)

    Ibrahim, Mounir; Gupta, Abhinav; Shyam, Vikram

    2014-01-01

    This paper presents preliminary findings on a possible approach to reducing tip leakage losses. In this paper a computational study was conducted on the Energy Efficient Engine (EEE) High Pressure Turbine (HPT) rotor tip geometry using the commercial numerical solver ANSYS FLUENT. The flow solver was validated against aerodynamic data acquired in the NASA Transonic Turbine Blade Cascade facility. The scope of the ongoing study is to computationally investigate how the tip leakage and overall blade losses are affected by (1) injection from the tip near the pressure side, (2) injection from the tip surface at the camber line, and (3) injection from the tip surface into the tip separation bubble. The objective is to identify the locations on the tip surface at which to place appropriately configured blowing keeping in mind the film cooling application of tip blowing holes. The validation was conducted at Reynolds numbers of 85,000, 343,000, and 685,000 and at engine realistic flow conditions. The coolant injection simulations were conducted at a Reynolds number of 343,000 based on blade chord and inlet velocity and utilized the SST turbulence model in FLUENT. The key parameters examined are the number of jets, jet angle and jet location. A coolant to inlet pressure ratio of 1.0 was studied for angles of +30 deg, -30 deg, and 90 deg to the local free stream on the tip. For the 3 hole configuration, 3 holes spaced 3 hole diameters apart with length to diameter ratio of 1.5 were used. A simulation including 11 holes along the entire mean camber line is also presented (30 deg toward suction side). In addition, the effect of a single hole is also compared to a flat tip with no injection. The results provide insight into tip flow control methods and can be used to guide further investigation into tip flow control. As noted in past research it is concluded that reducing leakage flow is not necessarily synonymous with reducing losses due to leakage.

  12. Effect of Tip-Speed Constraints on the Optimized Design of a Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, K.; Resor, B.; Platt, A.; Guo, Y.; Ning, A.; King, R.; Parsons, T.; Petch, D.; Veers, P.

    2014-10-01

    This study investigates the effect of tip-velocity constraints on system levelized cost of energy (LCOE). The results indicate that a change in maximum tip speed from 80 to 100~m/s could produce a 32% decrease in gearbox weight (a 33% reduction in cost) which would result in an overall reduction of 1%-9% in system LCOE depending on the design approach. Three 100~m/s design cases were considered including a low tip-speed ratio/high-solidity rotor design, a high tip-speed ratio/ low-solidity rotor design, and finally a flexible blade design in which a high tip-speed ratio was used along with removing the tip deflection constraint on the rotor design. In all three cases, the significant reduction in gearbox weight caused by the higher tip-speed and lower overall gear ratio was counterbalanced by increased weights for the rotor and/or other drivetrain components and the tower. As a result, the increased costs of either the rotor or drivetrain components offset the overall reduction in turbine costs from down-sizing the gearbox. Other system costs were not significantly affected, whereas energy production was slightly reduced in the 100~m/s case low tip-speed ratio case and increased in the high tip-speed ratio case. This resulted in system cost of energy reductions moving from the 80~m/s design to the 100~m/s designs of 1.2% for the low tip-speed ratio, 4.6% for the high tip-speed ratio, and 9.5% for the final flexible case (the latter result is optimistic because the impact of deflection of the flexible blade on power production was not modeled). Overall, the results demonstrate that there is a trade-off in system design between the maximum tip velocity and the overall wind plant cost of energy, and there are many trade-offs within the overall system in designing a turbine for a high maximum tip velocity.

  13. Characterization of SCC crack tips and surface oxide layers in alloy 600

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Katsuhiko; Fukuya, Koji [Inst. of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2002-09-01

    In order to investigate the mechanism of primary water stress corrosion cracking (SCC), direct observation of microstructures of SCC crack tips and surface oxide layers in alloy 600 were carried out. A focused-ion beam (FIB) micro-processing technique was applied to prepare electron transparent foils including the crack tip and the surface oxide layer without any damage to those microstructures. Transmission electron microscopy and analysis were used to characterize the crack tips and surface oxide layers. Cr-rich oxides and a metal-Ni phase were identified in the crack tips and grain boundaries ahead of the crack tips independent of dissolved hydrogen concentrations. >From the fact that the Cr-rich oxides and metal-Ni phase were observed in the inner surface oxide layer, the same oxidation mechanism as the surface is proposed for the crack tip region and internal oxidation accompanying selective Cr oxidation is suggested as the mechanism. (author)

  14. Top 10 "Secret Writing Tips" to Boost Your Productivity: Part 2

    Science.gov (United States)

    Berk, Ronald A.

    2011-01-01

    This is the sequel and companion piece to the first five tips published in this journal's winter 2010 issue. To recap, the first five tips are: (1) Write Everyday; (2) Write Everywhere; (3) Conquer Distractions and Interruptions; (4) Write for a Niche; and (5) Write with a Purpose. Now, in this article, the other five tips are discussed: (6) Write…

  15. Fitness: Tips for Staying Motivated

    Science.gov (United States)

    Healthy Lifestyle Fitness Fitness is for life. Motivate yourself with these practical tips. By Mayo Clinic Staff Have ... 27, 2015 Original article: http://www.mayoclinic.org/healthy-lifestyle/fitness/in-depth/fitness/art-20047624 . Mayo Clinic ...

  16. Functionalization of Probe Tips and Supports for Single-Molecule Recognition Force Microscopy

    Science.gov (United States)

    Ebner, Andreas; Wildling, Linda; Zhu, Rong; Rankl, Christian; Haselgrübler, Thomas; Hinterdorfer, Peter; Gruber, Hermann J.

    The measuring tip of a force microscope can be converted into a monomolecular sensor if one or few "ligand" molecules are attached to the apex of the tip while maintaining ligand function. Functionalized tips are used to study fine details of receptor-ligand interaction by force spectroscopy or to map cognate "receptor" molecules on the sample surface. The receptor (or target) molecules can be present on the surface of a biological specimen; alternatively, soluble target molecules must be immobilized on ultraflat supports. This review describes the methods of tip functionalization, as well as target molecule immobilization. Silicon nitride tips, silicon chips, and mica have usually been functionalized in three steps: (1) aminofunctionalization, (2) crosslinker attachment, and (3) ligand/receptor coupling, whereby numerous crosslinkers are available to couple widely different ligand molecules. Gold-covered tips and/or supports have usually been coated with a self-assembled monolayer, on top of which the ligand/receptor molecule has been coupled either directly or via a crosslinker molecule. Apart from these general strategies, many simplified methods have been used for tip and/or support functionalization, even single-step methods such as adsorption or chemisorption being very efficient under suitable circumstances. All methods are described with the same explicitness and critical parameters are discussed. In conclusion, this review should help to find suitable methods for specific problems of tip and support functionalization.

  17. Rapid tryptic mapping using enzymatically active mass spectrometer probe tips

    Energy Technology Data Exchange (ETDEWEB)

    Dogruel, D.; Williams, P.; Nelson, R.W. [Arizona State Univ., Tempe, AZ (United States)

    1995-12-01

    A method has been developed for rapid, sensitive, and accurate tryptic mapping of polypeptides using matrix-assisted laser desorption/ionization time-of-flight mass analysis. The technique utilizes mass spectrometer probe tips which have been activated through the covalent immobilization of trypsin. The enzymatically active probe tips were used for the tryptic mapping of chicken egg lysozyme and the results compared with those obtained using either free trypsin or agarose-immobilized trypsin. A significant increase in the overall sensitivity of the process was observed using the active probe tips, as well as the production of more characteristic proteolytic fragments and the elimination of background signals due to the autolysis of the trypsin. Further, probe tip digestions were found to be rapid and convenient. 19 refs., 6 figs., 2 tabs.

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ... limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening liver failure ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... hepatic vein to identify the portal venous system. Access is then gained from the hepatic vein into ... TIPS procedure to make sure that it remains open and functions properly. top of page Who interprets ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, allergies and medications you’re taking. You ... with ascites or variceal bleeding resistant to traditional medical treatments. The greatest difference in performing TIPS in ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... bleeding resistant to traditional medical treatments. The greatest difference in performing TIPS in children is their tremendous ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... complex and lengthy procedures requiring extended fluoroscopy use) death (rare) top of page What are the limitations ... filtered out by the liver. The TIPS may cause too much of these substances to bypass the ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in the chest or abdomen. This condition is most commonly seen in adults, often as a result ... minimally invasive procedures such as a TIPS are most often performed by a specially trained interventional radiologist ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... while avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients ... site. Using ultrasound, the doctor will identify your internal jugular vein , which is situated above your collarbone, ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... deeply you are sedated. When the needle is advanced through the liver and the pathway is expanded ... are the limitations of TIPS? Patients with more advanced liver disease are at greater risk for worsening ...

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... avoiding the liver. TIPS may successfully reduce internal bleeding in the stomach and esophagus in patients with ... stomach, lower esophagus, and intestines, causing enlarged vessels, bleeding and the accumulation of fluid in the chest ...

  7. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... surgery. Your TIPS should have less of an effect than open surgical bypass on future liver transplantation ... Encephalopathy can be treated with certain medications, a special diet or, by revising the stent, but sometimes ...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... to determine the severity of the condition. To help plan for the placement of the TIPS stent, ... Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... in creating the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  11. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the liver. A small metal device called a stent is placed to keep the connection open and ... a small, tubular metal device commonly called a stent . During a TIPS procedure, interventional radiologists use image ...

  12. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose ...

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... observed. This procedure is usually completed in an hour or two but may take up to several ...

  15. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the portal system using a TIPS needle (a special long needle extending from the neck into the ... Encephalopathy can be treated with certain medications, a special diet or, by revising the stent, but sometimes ...

  16. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... of bleeding that can occur can sometimes be life threatening and those patients are monitored in intensive ...

  17. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... blood draining from the bowel back to the heart while avoiding the liver. TIPS may successfully reduce ... blood away from the liver back to the heart). A stent is then placed in this tunnel ...

  18. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... portal vein to the hepatic vein in the liver. A small metal device called a stent is ... bowel back to the heart while avoiding the liver. TIPS may successfully reduce internal bleeding in the ...

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... physician will numb an area just above your right collarbone with a local anesthetic . A very small ...

  20. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal vein ... the local anesthetic is injected. Most of the sensation is at the skin incision site, which is ...

  1. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A TIPS is designed to produce the ... skin that does not have to be stitched. Risks Any procedure where the skin is penetrated carries ...

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Patients who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal ... leading to cirrhosis (scarring of the liver). Portal hypertension can also occur in children, although children are ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... pressure. top of page How does the procedure work? A TIPS reroutes blood flow in the liver ... above your collarbone, and guide a catheter, a long, thin, hollow plastic tube into the vessel. Using ...

  4. CO tip functionalization in subatomic resolution atomic force microscopy

    International Nuclear Information System (INIS)

    Kim, Minjung; Chelikowsky, James R.

    2015-01-01

    Noncontact atomic force microscopy (nc-AFM) employing a CO-functionalized tip displays dramatically enhanced resolution wherein covalent bonds of polycyclic aromatic hydrocarbon can be imaged. Employing real-space pseudopotential first-principles calculations, we examine the role of CO in functionalizing the nc-AFM tip. Our calculations allow us to simulate full AFM images and ascertain the enhancement mechanism of the CO molecule. We consider two approaches: one with an explicit inclusion of the CO molecule and one without. By comparing our simulations to existing experimental images, we ascribe the enhanced resolution of the CO functionalized tip to the special orbital characteristics of the CO molecule

  5. Risk-analysis of global climate tipping points

    Energy Technology Data Exchange (ETDEWEB)

    Frieler, Katja; Meinshausen, Malte; Braun, N [Potsdam Institute for Climate Impact Research e.V., Potsdam (Germany). PRIMAP Research Group; and others

    2012-09-15

    There are many elements of the Earth system that are expected to change gradually with increasing global warming. Changes might prove to be reversible after global warming returns to lower levels. But there are others that have the potential of showing a threshold behavior. This means that these changes would imply a transition between qualitatively disparate states which can be triggered by only small shifts in background climate (2). These changes are often expected not to be reversible by returning to the current level of warming. The reason for that is, that many of them are characterized by self-amplifying processes that could lead to a new internally stable state which is qualitatively different from before. There are different elements of the climate system that are already identified as potential tipping elements. This group contains the mass losses of the Greenland and the West-Antarctic Ice Sheet, the decline of the Arctic summer sea ice, different monsoon systems, the degradation of coral reefs, the dieback of the Amazon rainforest, the thawing of the permafrost regions as well as the release of methane hydrates (3). Crucially, these tipping elements have regional to global scale effects on human society, biodiversity and/or ecosystem services. Several examples may have a discernable effect on global climate through a large-scale positive feedback. This means they would further amplify the human induced climate change. These tipping elements pose risks comparable to risks found in other fields of human activity: high-impact events that have at least a few percent chance to occur classify as high-risk events. In many of these examples adaptation options are limited and prevention of occurrence may be a more viable strategy. Therefore, a better understanding of the processes driving tipping points is essential. There might be other tipping elements even more critical but not yet identified. These may also lie within our socio-economic systems that are

  6. Efficient regeneration of plants from shoot tip explants of ...

    African Journals Online (AJOL)

    Dendrobium densiflorum Lindl. is one of the horticulturally important orchids of Nepal due to its beautiful yellowish flower and medicinal properties. The present study was carried out for plant regeneration from shoot tip explants of D. densiflorum by tissue culture technique. The shoot tip explants of this species, obtained ...

  7. Girlfriends' Health and Safety Tips

    Science.gov (United States)

    ... in Women? Women's Safety and Health Issues at Work Health Equity Girlfriends' Health and Safety Tips Recommend on Facebook Tweet Share Compartir Having friends is an important part of life. Celebrate female friendship and support your girlfriends by ...

  8. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... and medical diseases. This can result in significant challenges in creating the TIPS. top of page Additional ... Please note RadiologyInfo.org is not a medical facility. Please contact your physician with specific medical questions ...

  9. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Intrahepatic Portosystemic Shunt (TIPS)? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  10. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... the TIPS. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient Center This ... here Images × Image Gallery Radiologist and patient consultation. View full size with caption Pediatric Content Some imaging ...

  11. Tips to Help Parents Manage Their Child's Asthma Every Day

    Science.gov (United States)

    ... Tips to Help Parents Manage Their Child's Asthma Every Day Past Issues / Fall 2013 Table of Contents Asthma ... Tips to Help Parents Manage Their Child's Asthma Every Day Fall 2013 Issue: Volume 8 Number 3 Page ...

  12. Recent trends in television tip over-related injuries among children aged 0-9 years.

    Science.gov (United States)

    Murray, K J; Griffin, R; Rue, L W; McGwin, G

    2009-08-01

    To describe recent trends in television tip over-related injuries among children aged 0-9 years, and to compare injury rates with sales of newer digital televisions. Digital television sales data were obtained from marketing data provided by the Television Bureau of Advertising. Data regarding television tip over-related injuries among children aged 0-9 years were obtained from the 1998-2007 National Electronic Injury Surveillance System. A Wald chi(2) test, estimated from logistic analysis, was used to determine whether the distribution of injury types differed by age group. Pearson's correlation was used to estimate the association between digital television sales and television tip over-related injuries. An estimated 42 122 (95% CI 35 199 to 49 122) injuries from television tip-overs were treated in US emergency departments from 1998 to 2007. The injury rate was highest for children aged 1-4 years (18.6/100 000). A majority of injuries (63.9%) involved the head and neck for children under 1 year of age, while a higher proportion of injuries among children aged 1-4 involved the hip and lower extremity (42.9% and 31.0%, respectively), and shoulder and upper extremity (16.8%) for children aged 5-9. A strong, positive correlation was observed between television sales and annual injury rates (r = 0.89, pdigital television sales were strongly correlated with increased injury rates, the lack of information regarding the type of television involved prevents inference regarding causation.

  13. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... open. Patients who typically need a TIPS have portal hypertension , meaning they have increased pressure in the portal ... problems leading to cirrhosis (scarring of the liver). Portal hypertension can also occur in children, although children are ...

  14. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  15. z calibration of the atomic force microscope by means of a pyramidal tip

    DEFF Research Database (Denmark)

    Jensen, Flemming

    1993-01-01

    A new method for imaging the probe tip of an atomic force microscope cantilever by the atomic force microscope itself (self-imaging) is presented. The self-imaging is accomplished by scanning the probe tip across a sharper tip on the surface. By using a pyramidal probe tip with a very well......-defined aspect ratio, this technique provides an excellent z-calibration standard for the atomic force microscope....

  16. Optical properties of boron carbide near the boron K edge evaluated by soft-x-ray reflectometry from a Ru/B4C multilayer

    Energy Technology Data Exchange (ETDEWEB)

    Ksenzov, Dmitriy; Panzner, Tobias; Schlemper, Christoph; Morawe, Christian; Pietsch, Ullrich

    2009-12-10

    Soft-x-ray Bragg reflection from two Ru/B4C multilayers with 10 and 63 periods was used for independent determination of both real and imaginary parts of the refractive index n = 1 -{delta} + i{beta} close to the boron K edge ({approx}188 eV). Prior to soft x-ray measurements, the structural parameters of the multilayers were determined by x-ray reflectometry using hard x rays. For the 63-period sample, the optical properties based on the predictions made for elemental boron major deviations were found close to the K edge of boron for the 10-period sample explained by chemical bonding of boron to B4C and various boron oxides.

  17. Effects of increasing tip velocity on wind turbine rotor design.

    Energy Technology Data Exchange (ETDEWEB)

    Resor, Brian Ray [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Maniaci, David Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Berg, Jonathan Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Richards, Phillip William [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-05-01

    A reduction in cost of energy from wind is anticipated when maximum allowable tip velocity is allowed to increase. Rotor torque decreases as tip velocity increases and rotor size and power rating are held constant. Reduction in rotor torque yields a lighter weight gearbox, a decrease in the turbine cost, and an increase in the capacity for the turbine to deliver cost competitive electricity. The high speed rotor incurs costs attributable to rotor aero-acoustics and system loads. The increased loads of high speed rotors drive the sizing and cost of other components in the system. Rotor, drivetrain, and tower designs at 80 m/s maximum tip velocity and 100 m/s maximum tip velocity are created to quantify these effects. Component costs, annualized energy production, and cost of energy are computed for each design to quantify the change in overall cost of energy resulting from the increase in turbine tip velocity. High fidelity physics based models rather than cost and scaling models are used to perform the work. Results provide a quantitative assessment of anticipated costs and benefits for high speed rotors. Finally, important lessons regarding full system optimization of wind turbines are documented.

  18. Thermal Diffusion Processes in Metal-Tip-Surface Interactions: Contact Formation and Adatom Mobility

    DEFF Research Database (Denmark)

    Sørensen, Mads Reinholdt; Jacobsen, Karsten Wedel; Jonsson, Hannes

    1996-01-01

    and the surface can occur by a sequence of atomic hop and exchange processes which become active on a millisecond time scale when the tip is about 3-5 Angstrom from the surface. Adatoms on the surface are stabilized by the presence of the tip and energy barriers for diffusion processes in the region under the tip......We have carried out computer simulations to identify and characterize various thermally activated atomic scale processes that can play an important role in room temperature experiments where a metal tip is brought close to a metal surface. We find that contact formation between the tip...

  19. Experimental investigation on preconditioned rate induced tipping in a thermoacoustic system.

    Science.gov (United States)

    Tony, J; Subarna, S; Syamkumar, K S; Sudha, G; Akshay, S; Gopalakrishnan, E A; Surovyatkina, E; Sujith, R I

    2017-07-14

    Many systems found in nature are susceptible to tipping, where they can shift from one stable dynamical state to another. This shift in dynamics can be unfavorable in systems found in various fields ranging from ecology to finance. Hence, it is important to identify the factors that can lead to tipping in a physical system. Tipping can mainly be brought about by a change in parameter or due to the influence of external fluctuations. Further, the rate at which the parameter is varied also determines the final state that the system attains. Here, we show preconditioned rate induced tipping in experiments and in a theoretical model of a thermoacoustic system. We provide a specific initial condition (preconditioning) and vary the parameter at a rate higher than a critical rate to observe tipping. We find that the critical rate is a function of the initial condition. Our study is highly relevant because the parameters that dictate the asymptotic behavior of many physical systems are temporally dynamic.

  20. Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study.

    Science.gov (United States)

    Kwak, Sang-Won; Moon, Young-Mi; Yoo, Yeon-Jee; Baek, Seung-Ho; Lee, WooCheol; Kim, Hyeon-Cheol

    2014-11-01

    The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. The apical 3-mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

  1. Tip preparation for usage in an ultra-low temperature UHV scanning tunneling microscope

    Directory of Open Access Journals (Sweden)

    S. Ernst, S. Wirth, M. Rams, V. Dolocan and F. Steglich

    2007-01-01

    Full Text Available This work deals with the preparation and characterization of tungsten tips for the use in UHV low-temperature scanning tunneling microscopy and spectroscopy (STM and STS, respectively. These specific environments require in situ facilities for tip conditioning, for further sharpening of the tips, as well as for reliable tip characterization. The implemented conditioning methods include direct resistive annealing, annealing by electron bombardment, and self-sputtering with noble gas ions. Moreover, results from in situ tip characterization by field emission and STM experiments were compared to ex situ scanning electron microscopy. Using the so-prepared tips, high resolution STM images and tunneling spectra were obtained in a temperature range from ambient down to 350 mK, partially with applied magnetic field, on a variety of materials.

  2. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... is completed. top of page What are the benefits vs. risks? Benefits A TIPS is designed to produce the same ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... Portosystemic Shunt (TIPS) Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ... links: For the convenience of our users, RadiologyInfo .org provides links to relevant websites. RadiologyInfo.org , ACR ...

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... procedure work? How is the procedure performed? What will I experience during and after the procedure? Who interprets the results and how do I get them? What are the benefits vs. risks? What are the limitations of TIPS? ...

  5. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... thin, hollow plastic tube into the vessel. Using real time x-ray guidance, your doctor will then guide ... invasive procedure that typically has a shorter recovery time than surgery. Your TIPS should have less of an effect ...

  6. Onion root tip cell system for biodosimetry?

    International Nuclear Information System (INIS)

    Paradiz, J; Druskovic, B.; Lovka, M.; Skrk, J.

    1996-01-01

    Methodology for radiation dose assessment based on chromosomal damage to plant cells has no yet been established, although root meristems have been the pioneer cytogenetic materials and profound analyses of irradiated meristematic cells of horse bean (Viciafaba L.) had been performed. Onion (Allium cepa L.) root tips frequently used for radiation cytogenetic studies, are recently considered to be one of the most promising plant test system for the detection of genotoxic environmental pollutants. We studied the possibility of using cytogenetic analyses of irradiated onion cells to determine the effective biological dose of ionizing radiation. The dose-effect relationships for chromosomal damages to onion meristematic cells were established after plants had been irradiated and subsequently grown in both laboratory and field conditions

  7. Homogeneous nucleation of water in argon : nucleation rate computation from molecular simulations of TIP4P and TIP4P/2005 water model

    NARCIS (Netherlands)

    Dumitrescu, Lucia R.; Smeulders, David M.J.; Dam, Jacques A.M.; Gaastra-Nedea, Silvia V.

    2017-01-01

    Molecular dynamics (MD) simulations were conducted to study nucleation of water at 350 K in argon using TIP4P and TIP4P/2005 water models. We found that the stability of any cluster, even if large, strongly depends on the energetic interactions with its vicinity, while the stable clusters change

  8. SPOT WELDING COPPER–1%Cr ELECTRODE TIPS PRODUCED VIA EQUAL CHANNEL ANGULAR PRESSING

    Directory of Open Access Journals (Sweden)

    Luay Bakir Hussain

    2010-09-01

    Full Text Available A sharp 120o Equal channel angular pressing (ECAP following rout Bc was applied at room temperature to refine the grains sizes of pure copper and copper-1%Chromium alloy for spot welding electrode tips application. Initially deformation behavior was investigated with the position using colorful plasticine as work piece followed by copper alloy. It was found the deformation at the central part of the work piece is heavily sheared than the outer part. Optical and Scanning electron microscopy were used to study the progress of grain refining under the influence of rotation and number of passes during pressing. The influnece of elongated fibrous nano graines on electrical conductivity and hardness were discussed. Shear test of spot welded 303 stainless steel indicated that nano structural Cu-1%Cr electrode tips used showed a superior results compared to commercial electrodes

  9. Note: Automated electrochemical etching and polishing of silver scanning tunneling microscope tips.

    Science.gov (United States)

    Sasaki, Stephen S; Perdue, Shawn M; Rodriguez Perez, Alejandro; Tallarida, Nicholas; Majors, Julia H; Apkarian, V Ara; Lee, Joonhee

    2013-09-01

    Fabrication of sharp and smooth Ag tips is crucial in optical scanning probe microscope experiments. To ensure reproducible tip profiles, the polishing process is fully automated using a closed-loop laminar flow system to deliver the electrolytic solution to moving electrodes mounted on a motorized translational stage. The repetitive translational motion is controlled precisely on the μm scale with a stepper motor and screw-thread mechanism. The automated setup allows reproducible control over the tip profile and improves smoothness and sharpness of tips (radius 27 ± 18 nm), as measured by ultrafast field emission.

  10. Study on the Effect of the Impact Location and the Type of Hammer Tip on the Frequency Response Function (FRF) in Experimental Modal Analysis of Rectangular Plates

    Science.gov (United States)

    Mali, K. D.; Singru, P. M.

    2018-03-01

    In this work effect of the impact location and the type of hammer tip on the frequency response function (FRF) is studied. Experimental modal analysis of rectangular plates is carried out for this purpose by using impact hammer, accelerometer and fast Fourier transform (FFT) analyzer. It is observed that the impulse hammer hit location has, no effect on the eigenfrequency, yet a difference in amplitude of the eigenfrequencies is obtained. The effect of the hammer tip on the pulse and the force spectrum is studied for three types of tips metal, plastic and rubber. A solid rectangular plate was excited by using these tips one by one in three different tests. It is observed that for present experimental set up plastic tip excites the useful frequency range.

  11. Nanomechanical probing of soft matter through hydrophobic AFM tips fabricated by two-photon polymerization

    International Nuclear Information System (INIS)

    Suriano, Raffaella; De Marco, Carmela; Turri, Stefano; Zandrini, Tommaso; Osellame, Roberto; Bragheri, Francesca

    2016-01-01

    Atomic force microscopy (AFM) nanoindentation of soft materials is a powerful tool for probing mechanical properties of biomaterials. Though many results have been reported in this field over the last decade, adhesion forces between the tip and the sample hinder the elastic modulus measurement when hydrophilic soft samples are investigated. Here, two-photon polymerization (2PP) technology was used to fabricate hydrophobic perfluoropolyether-based AFM tips. The hydrophobic 2PP tips allowed us to overcome the limitations of commercial and functionalized tips as well as to successfully measure the elastic modulus of medically relevant soft materials in air. Our results obtained in the characterization of poly(dimethyl siloxane) and polyethylene glycol hydrogels showed lower adhesion forces over a larger measurement range when compared to measurements performed with commercial tips. The elastic moduli measured by means of hydrophobic 2PP AFM tips were also found to be comparable to those obtained using conventional techniques for macroscopic samples. We successfully showed that the hydrophobic AFM tips developed by this highly versatile technology enable the study of mechanical properties of soft matter, benefiting from reduced sample–tip interactions, and a custom-made shape and dimension of the tips. (paper)

  12. Micro-raman and tip-enhanced raman spectroscopy of carbon allotropes

    NARCIS (Netherlands)

    Hoffmann, G.G.; With, de G.; Loos, J.

    2008-01-01

    Raman spectroscopic data are obtained on various carbon allotropes like diamond, amorphous carbon, graphite, graphene and single wall carbon nanotubes by micro-Raman spectroscopy, tip-enhanced Raman spectroscopy and tip-enhanced Raman spectroscopy imaging, and the potentials of these techniques for

  13. Modelling the embedded rainfall process using tipping bucket data

    DEFF Research Database (Denmark)

    Thyregod, Peter; Arnbjerg-Nielsen, Karsten; Madsen, Henrik

    1998-01-01

    A new method for modelling the dynamics of rain measurement processes is suggested. The method takes the discrete nature and autocorrelation of measurements from the tipping bucket rain gauge into consideration. The considered model is a state space model with a Poisson marginal distribution....... In the model there is only one parameter, a thinning parameter. The model is tested on 39 rain events. The estimated value for the various rain events is reflecting a subjective classification of rain events into frontal and convective rain. Finally, it is demonstrated how the model can be used for simulation...

  14. Experimental investigation of turbine blade-tip excitation forces

    Science.gov (United States)

    Martinez-Sanchez, Manuel; Jaroux, Belgacem; Song, Seung Jin; Yoo, Soom-Yung; Palczynski, Taras

    1994-01-01

    Results of a program to investigate the magnitude and parametric variations of rotordynamic forces which arise in high power turbines due to blade-tip leakage effects are presented. Five different unshrouded turbine configurations and one configuration shrouded with a labyrinth seal were tested with static offsets of the turbine shaft. The forces along and perpendicular to the offset were measured directly with a rotating dynometer. Exploration of casing pressure and flow velocity distributions was used to investigate the force-generating mechanisms. For unshrouded turbines, the cross-forces originate mainly from the classical Alford mechanisms while the direct forces arise mainly from a slightly skewed pressure pattern. The Alford coefficient for cross-force was found to vary between 2.4 and 4.0, while the similar direct force coefficient varied from 1.5 to 3.5. The cross-forces are found to increase substantially when the gap is reduced from 3.0 to 1.9% of blade height, probably due to viscous blade-tip effects. The forces also increase when the hub gap between stator and rotor decreases. The force coefficient decreased with operating flow coefficient. In the case of the shrouded turbine, most of the forces arise from nonuniform seal pressures. This includes about 80% for the transverse forces. The rest appears to come from uneven work extraction. Their level is about 50% higher in the shrouded case.

  15. Adjusting the displaced tip of peripherally inserted central catheter under DSA guidance

    International Nuclear Information System (INIS)

    Mao Yanjun; Dong Huijuan; Zhang Lingjuan; Li Hongmei; Xu Lianqin

    2009-01-01

    Objective: To explore a new method to adjust the displaced tip of peripherally inserted central catheter (PICC) under DSA guidance. Methods: Under DSA guidance, the displaced tip of PICC was repositioned to the ideal junction area of superior vena cava with right atrium with proper manipulation. Results: Under DSA guidance, the displaced tip of PICC was successfully corrected in 13 cases. The mean operative time was 15.53 minutes, which was markedly shorter than that needed by blind adjusting beside the bed. Conclusion: The displacement of PICC tip is a common occurrence, which is hard to be avoided. Under DSA guidance, the adjusting manipulation of the displaced PICC tip is safe and time-saving with high successful rate. It is worth popularizing this technique in clinical practice. (authors)

  16. Effect of plastic prestrain on the crack tip constraint of pipeline steels

    International Nuclear Information System (INIS)

    Eikrem, P.A.; Zhang, Z.L.; Nyhus, B.

    2007-01-01

    Before and during operation, pipelines may suffer from plastic pre-deformation due to accidental loading, cold bending and ground movement. Plastic prestrain not only modifies steel's yield and flow properties but also influences its fracture performance. This paper focuses on the effect of prestrain history on crack driving force and crack tip constraint. A single-edge notched tension specimen has been selected for the study and the crack is assumed to exist before a prestrain history was applied. The results show that prestrain history has a strong effect on the crack tip stress field. A new parameter has been proposed to characterize the prestrain-induced crack tip constraint. For the same crack tip opening displacement level, prestrain history will elevate the crack tip stress field. The prestrain-induced constraint decreases with the increase of loading

  17. Build Your Child's Vocabulary! Ten Fun and Easy Tips.

    Science.gov (United States)

    1998

    This booklet presents parents with 10 tips for helping their children expand their vocabulary. The 10 tips in the booklet are: read and use context; look for synonyms and antonyms; rhyming and homophones; compound words; look for related words; prefixes and suffixes; word maps; see how words are formed; mine the wealth of other languages; and use…

  18. Geomorphic tipping points: convenient metaphor or fundamental landscape property?

    Science.gov (United States)

    Lane, Stuart

    2016-04-01

    In 2000 Malcolm Gladwell published as book that has done much to publicise Tipping Points in society but also in academia. His arguments, re-expressed in a geomorphic sense, have three core elements: (1) a "Law of the Few", where rapid change results from the effects of a relatively restricted number of critical elements, ones that are able to rapidly connect systems together, that are particularly sensitive to an external force, of that are spatially organised in a particular way; (2) a "Stickiness" where an element of the landscape is able to assimilate characteristics which make it progressively more applicable to the "Law of the Few"; and (3), given (1) and (2) a history and a geography that means that the same force can have dramatically different effects, according to where and when it occurs. Expressed in this way, it is not clear that Tipping Points bring much to our understanding in geomorphology that existing concepts (e.g. landscape sensitivity and recovery; cusp-catastrophe theory; non-linear dynamics systems) do not already provide. It may also be all too easy to describe change in geomorphology as involving a Tipping Point: we know that geomorphic processes often involve a non-linear response above a certain critical threshold; we know that landscapes can, after Denys Brunsden, be though of as involving long periods of boredom ("stability") interspersed with brief moments of terror ("change"); but these are not, after Gladwell, sufficient for the term Tipping Point to apply. Following from these issues, this talk will address three themes. First, it will question, through reference to specific examples, notably in high Alpine systems, the extent to which the Tipping Point analogy is truly a property of the world in which we live. Second, it will explore how 'tipping points' become assigned metaphorically, sometimes evolving to the point that they themselves gain agency, that is, shaping the way we interpret landscape rather than vice versa. Third, I

  19. Attached cavitation at a small diameter ultrasonic horn tip

    Science.gov (United States)

    Žnidarčič, Anton; Mettin, Robert; Cairós, Carlos; Dular, Matevž

    2014-02-01

    Ultrasonic horn transducers are frequently used in applications of acoustic cavitation in liquids, for instance, for cell disruption or sonochemical reactions. They are operated typically in the frequency range up to about 50 kHz and have tip diameters from some mm to several cm. It has been observed that if the horn tip is sufficiently small and driven at high amplitude, cavitation is very strong, and the tip can be covered entirely by the gas/vapor phase for longer time intervals. A peculiar dynamics of the attached cavity can emerge with expansion and collapse at a self-generated frequency in the subharmonic range, i.e., below the acoustic driving frequency. Here, we present a systematic study of the cavitation dynamics in water at a 20 kHz horn tip of 3 mm diameter. The system was investigated by high-speed imaging with simultaneous recording of the acoustic emissions. Measurements were performed under variation of acoustic power, air saturation, viscosity, surface tension, and temperature of the liquid. Our findings show that the liquid properties play no significant role in the dynamics of the attached cavitation at the small ultrasonic horn. Also the variation of the experimental geometry, within a certain range, did not change the dynamics. We believe that the main two reasons for the peculiar dynamics of cavitation on a small ultrasonic horn are the higher energy density on a small tip and the inability of the big tip to "wash" away the gaseous bubbles. Calculation of the somewhat adapted Strouhal number revealed that, similar to the hydrodynamic cavitation, values which are relatively low characterize slow cavitation structure dynamics. In cases where the cavitation follows the driving frequency this value lies much higher - probably at Str > 20. In the spirit to distinguish the observed phenomenon with other cavitation dynamics at ultrasonic transducer surfaces, we suggest to term the observed phenomenon of attached cavities partly covering the full horn

  20. Functionalization of gold and nanocrystalline diamond atomic force microscope tips for single molecule force spectroscopy

    Science.gov (United States)

    Drew, Michael E.

    The atomic force microscope (AFM) has fueled interest in nanotechnology because of its ability to image surfaces at the nanometer level and act as a molecular force sensor. Functionalization of the surface of an AFM tip surface in a stable, controlled manner expands the capabilities of the AFM and enables additional applications in the fields of single molecule force spectroscopy and nanolithography. Two AFM tip functionalizations are described: the assembly of tripodal molecular tips onto gold AFM tips and the photochemical attachment of terminal alkenes to nanocrystalline diamond (NCD) AFM tips. Two separate tripodal molecules with different linker lengths and a monopodal molecule terminated with biotin were synthesized to attach to a gold AFM tip for single molecule force spectroscopy. The immobilization of these molecules was examined by contact angle measurements, spectroscopic ellipsometry, infrared, and near edge x-ray absorption fine structure (NEXAFS) spectroscopy. All three molecules displayed rupture forces that agreed with previously reported values for the biotin--avidin rupture. The tripodal molecular tip displayed narrower distribution in their force histograms than the monopodal molecular tip. The performance of the tripodal molecular tip was compared to the monopodal molecular tip in single molecule force spectroscopy studies. Over repeated measurements, the distribution of forces for the monopodal molecular tip shifted to lower forces, whereas the distribution for the tripodal molecular tip remained constant throughout. Loading rate dependence and control experiments further indicated that the rupture forces of the tripod molecular tips were specific to the biotin--NeutrAvidin interaction. The second functionalization method used the photochemical attachment of undecylenic acid to NCD AFM tips. The photochemical attachment of undecylenic acid to hydrogen-terminated NCD wafer surfaces was investigated by contact angle measurements, x