WorldWideScience

Sample records for time x-ray diffraction

  1. Theory of time-resolved inelastic x-ray diffraction

    DEFF Research Database (Denmark)

    Lorenz, Ulf; Møller, Klaus Braagaard; Henriksen, Niels Engholm

    2010-01-01

    Starting from a general theory of time-resolved x-ray scattering, we derive a convenient expression for the diffraction signal based on a careful analysis of the relevant inelastic scattering processes. We demonstrate that the resulting inelastic limit applies to a wider variety of experimental...... conditions than similar, previously derived formulas, and it directly allows the application of selection rules when interpreting diffraction signals. Furthermore, we present a simple extension to systems simultaneously illuminated by x rays and a laser beam....

  2. On the theory of time-resolved x-ray diffraction

    DEFF Research Database (Denmark)

    Henriksen, Niels Engholm; Møller, Klaus Braagaard

    2008-01-01

    We derive the basic theoretical formulation for X-ray diffraction with pulsed fields, using a fully quantized description of light and matter. Relevant time scales are discussed for coherent as well as incoherent X-ray pulses, and we provide expressions to be used for calculation...... of the experimental diffraction signal for both types of X-ray sources. We present a simple analysis of time-resolved X-ray scattering for direct bond breaking in diatomic molecules. This essentially analytical approach highlights the relation between the signal and the time-dependent quantum distribution...

  3. X-ray diffraction

    International Nuclear Information System (INIS)

    Einstein, J.R.; Wei, C.H.

    1982-01-01

    We have been interested in structural elucidation by x-ray diffraction of compounds of biological interest. Understanding exactly how atoms are arranged in three-dimensional arrays as molecules can help explain the relationship between structure and functions. The species investigated may vary in size and shape; our recent studies included such diverse substances as antischistosomal drugs, a complex of cadmium with nucleic acid base, nitrate salts of adenine, and proteins

  4. X-ray diffraction

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of literature on X-ray diffraction begins with a list of conference proceedings on the subject, organised by the Philips' organisation at regular intervals in various European countries. This is followed by a list of bulletins. The bibliography is divided according to the equipment (cameras, diffractometers, monochromators) and its applications. The applications are subdivided into sections for high/low temperature and pressure, effects due to the equipment, small angle scattering and a part for stress, texture and phase analyses of metals and quantitative analysis of minerals

  5. Ultrafast Structural Dynamics in InSb Probed by Time-Resolved X-Ray Diffraction

    International Nuclear Information System (INIS)

    Chin, A.H.; Shank, C.V.; Chin, A.H.; Schoenlein, R.W.; Shank, C.V.; Glover, T.E.; Leemans, W.P.; Balling, P.

    1999-01-01

    Ultrafast structural dynamics in laser-perturbed InSb are studied using time-resolved x-ray diffraction with a novel femtosecond x-ray source. We report the first observation of a delay in the onset of lattice expansion, which we attribute to energy relaxation processes and lattice strain propagation. In addition, we observe direct indications of ultrafast disordering on a subpicosecond time scale. copyright 1999 The American Physical Society

  6. Direct observation of ultrafast atomic motion using time-resolved X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Shymanovich, U.

    2007-11-13

    This thesis is dedicated to the study of the atomic motion in laser irradiated solids on a picosecond to subpicosecond time-scale using the time-resolved X-ray diffraction technique. In the second chapter, the laser system, the laser-plasma based X-ray source and the experimental setup for optical pump / X-ray probe measurements were presented. Chapter 3 is devoted to the characterization and comparison of different types of X-ray optics. Chapter 4 presented the time-resolved X-ray diffraction experiments performed for this thesis. The first two sections of this chapter discuss the measurements of initially unexpected strain-induced transient changes of the integrated reflectivity of the X-ray probe beam. The elimination of the strain-induced transient changes of the integrated reflectivity represented an important prerequisite to perform the study of lattice heating in Germanium after femtosecond optical excitation by measuring the transient Debye-Waller effect. The third section describes the investigations of acoustic waves upon ultrafast optical excitation and discusses the two different pressure contributions driving them: the thermal and the electronic ones. (orig.)

  7. Direct observation of ultrafast atomic motion using time-resolved X-ray diffraction

    International Nuclear Information System (INIS)

    Shymanovich, U.

    2007-01-01

    This thesis is dedicated to the study of the atomic motion in laser irradiated solids on a picosecond to subpicosecond time-scale using the time-resolved X-ray diffraction technique. In the second chapter, the laser system, the laser-plasma based X-ray source and the experimental setup for optical pump / X-ray probe measurements were presented. Chapter 3 is devoted to the characterization and comparison of different types of X-ray optics. Chapter 4 presented the time-resolved X-ray diffraction experiments performed for this thesis. The first two sections of this chapter discuss the measurements of initially unexpected strain-induced transient changes of the integrated reflectivity of the X-ray probe beam. The elimination of the strain-induced transient changes of the integrated reflectivity represented an important prerequisite to perform the study of lattice heating in Germanium after femtosecond optical excitation by measuring the transient Debye-Waller effect. The third section describes the investigations of acoustic waves upon ultrafast optical excitation and discusses the two different pressure contributions driving them: the thermal and the electronic ones. (orig.)

  8. X-ray diffraction using the time structure of the SRS

    International Nuclear Information System (INIS)

    Tanner, B.K.

    1983-01-01

    The subject is discussed under the headings: introduction (advances in the techniques of X-ray topography; comparison with transmission electron microscopy); stroboscopic X-ray topography; stroboscopic X-ray topography of travelling surface acoustic waves; possible general diffraction experiments. (U.K.)

  9. Time and space domain separation of pulsed X-ray beams diffracted from vibrating crystals

    Energy Technology Data Exchange (ETDEWEB)

    Nosik, V. L., E-mail: v-nosik@yandex.ru, E-mail: nosik@ns.crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Scientific Research Centre “Crystallography and Photonics,” (Russian Federation)

    2016-11-15

    It is known that a set of additional reflections (satellites) may arise on rocking curves in the case of X-ray diffraction in the Bragg geometry from crystals where high-frequency ultrasonic vibrations are excited. It is shown that, under certain conditions, the pulse wave fields of the satellites and main reflection may be intersected in space (playing the role of pump and probe beams) and in time (forming interference superlattices).

  10. A system for time-resolved x-ray diffraction and its application to muscle contraction

    International Nuclear Information System (INIS)

    Amemiya, Yoshiyuki; Hashizume, Hiroo.

    1979-01-01

    A data-collection system has been built which permits time-resolved studies of X-ray diffraction diagrams obtained from contracting muscle on millisecond time scale. The system consists of a linear delay-line position sensitive proportional counter (PSPC), a special data transfer unit and an on-line computer. The PSPC used with a mirror-monochromator camera can detect equatorial reflections from stimulated muscle in a total exposure time of a few seconds. Time-resolved data-collection is achieved by stimulating muscle at a regular time interval, dividing a complete cycle of muscle contraction into many successive time slices and accumulating in computer memory X-ray data for each time slice from many repeated cycles of stimulation. The performances of the system have been demonstrated by recording equatorial reflections from frog skeletal muscle during isometric and isotonic twitch with a time resolution of 25 ms. (author)

  11. Time-resolved x-ray diffraction techniques for bulk polycrystalline materials under dynamic loading

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, P. K.; Hustedt, C. J.; Zhao, M.; Ananiadis, A. G.; Hufnagel, T. C. [Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Vecchio, K. S. [Department of NanoEngineering, University of California San Diego, La Jolla, California 92093 (United States); Huskins, E. L. [Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee 37830 (United States); US Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, Maryland 21005 (United States); Casem, D. T. [US Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, Maryland 21005 (United States); Gruner, S. M. [Department of Physics, Cornell University, Ithaca, New York 14853 (United States); Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, New York 14853 (United States); Kavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, New York 14853 (United States); Tate, M. W.; Philipp, H. T.; Purohit, P.; Weiss, J. T. [Department of Physics, Cornell University, Ithaca, New York 14853 (United States); Woll, A. R. [Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, New York 14853 (United States); Kannan, V.; Ramesh, K. T. [Department of Mechanical Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Kenesei, P.; Okasinski, J. S.; Almer, J. [X-ray Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

    2014-09-15

    We have developed two techniques for time-resolved x-ray diffraction from bulk polycrystalline materials during dynamic loading. In the first technique, we synchronize a fast detector with loading of samples at strain rates of ∼10{sup 3}–10{sup 4} s{sup −1} in a compression Kolsky bar (split Hopkinson pressure bar) apparatus to obtain in situ diffraction patterns with exposures as short as 70 ns. This approach employs moderate x-ray energies (10–20 keV) and is well suited to weakly absorbing materials such as magnesium alloys. The second technique is useful for more strongly absorbing materials, and uses high-energy x-rays (86 keV) and a fast shutter synchronized with the Kolsky bar to produce short (∼40 μs) pulses timed with the arrival of the strain pulse at the specimen, recording the diffraction pattern on a large-format amorphous silicon detector. For both techniques we present sample data demonstrating the ability of these techniques to characterize elastic strains and polycrystalline texture as a function of time during high-rate deformation.

  12. Time-resolved X-ray diffraction with accelerator- and laser-plasma-based X-ray sources

    International Nuclear Information System (INIS)

    Nicoul, Matthieu

    2010-01-01

    Femtosecond X-ray pulses are a powerful tool to investigate atomic motions triggered by femtosecond pump pulses. This thesis is dedicated to the production of such pulses and their use in optical pump - X-ray probe measurement. This thesis describes the laser-plasma-based sources available at the University of Duisburg-Essen. Part of it consists of the description of the design, built-up and characterization of a new ''modular'' X-ray source dedicated to optimize the X-ray flux onto the sample under investigation. The acoustic wave generation in femtosecond optically excited semiconductor (gallium arsenide) and metal (gold) was performed using the sources of the University of Duisburg-Essen. The physical answer of the material was modeled by a simple strain model for the semiconductor, pressure model for the metal, in order to gain information on the interplay of the electronic and thermal pressures rising after excitation. Whereas no reliable information could be obtain in gallium arsenide (principally due to the use of a bulk), the model for gold achieved very good agreement, providing useful information. The relaxation time of the electron to lattice energy was found to be (5.0±0.3) ps, and the ratio of the Grueneisen parameters was found to be γ e / γ i = (0.5±0.1). This thesis also describes the Sub-Picosecond Pulse Source (SPPS) which existed at the (formally) Stanford Linear Accelerator Center, an accelerator-based X-ray source, and two measurements performed with it. The first one is the detailed investigation of the phonon softening of the A 1g mode launch in bismuth upon fluence excitation. Detailed information concerning the new equilibrium position and phonon frequency were obtained over extended laser pump fluences. The second measurement concerned the study of the liquid phase dynamics in a newly formed liquid phase following ultrafast melting in indium antimonide. The formation of the liquid phase and its development for excitations close to the

  13. Time-resolved X-ray diffraction with accelerator- and laser-plasma-based X-ray sources

    Energy Technology Data Exchange (ETDEWEB)

    Nicoul, Matthieu

    2010-09-01

    Femtosecond X-ray pulses are a powerful tool to investigate atomic motions triggered by femtosecond pump pulses. This thesis is dedicated to the production of such pulses and their use in optical pump - X-ray probe measurement. This thesis describes the laser-plasma-based sources available at the University of Duisburg-Essen. Part of it consists of the description of the design, built-up and characterization of a new ''modular'' X-ray source dedicated to optimize the X-ray flux onto the sample under investigation. The acoustic wave generation in femtosecond optically excited semiconductor (gallium arsenide) and metal (gold) was performed using the sources of the University of Duisburg-Essen. The physical answer of the material was modeled by a simple strain model for the semiconductor, pressure model for the metal, in order to gain information on the interplay of the electronic and thermal pressures rising after excitation. Whereas no reliable information could be obtain in gallium arsenide (principally due to the use of a bulk), the model for gold achieved very good agreement, providing useful information. The relaxation time of the electron to lattice energy was found to be (5.0{+-}0.3) ps, and the ratio of the Grueneisen parameters was found to be {gamma}{sub e} / {gamma}{sub i} = (0.5{+-}0.1). This thesis also describes the Sub-Picosecond Pulse Source (SPPS) which existed at the (formally) Stanford Linear Accelerator Center, an accelerator-based X-ray source, and two measurements performed with it. The first one is the detailed investigation of the phonon softening of the A{sub 1g} mode launch in bismuth upon fluence excitation. Detailed information concerning the new equilibrium position and phonon frequency were obtained over extended laser pump fluences. The second measurement concerned the study of the liquid phase dynamics in a newly formed liquid phase following ultrafast melting in indium antimonide. The formation of the liquid phase

  14. Atomic motion of resonantly vibrating quartz crystal visualized by time-resolved X-ray diffraction

    International Nuclear Information System (INIS)

    Aoyagi, Shinobu; Osawa, Hitoshi; Sugimoto, Kunihisa; Fujiwara, Akihiko; Takeda, Shoichi; Moriyoshi, Chikako; Kuroiwa, Yoshihiro

    2015-01-01

    Transient atomic displacements during a resonant thickness-shear vibration of AT-cut α-quartz are revealed by time-resolved X-ray diffraction under an alternating electric field. The lattice strain resonantly amplified by the alternating electric field is ∼10 4 times larger than that induced by a static electric field. The resonantly amplified lattice strain is achieved by fast displacements of oxygen anions and collateral resilient deformation of Si−O−Si angles bridging rigid SiO 4 tetrahedra, which efficiently transduce electric energy into elastic energy

  15. Time-Resolved Soft X-ray Diffraction Reveals Transient Structural Distortions of Ternary Liquid Crystals

    Directory of Open Access Journals (Sweden)

    Klaus Mann

    2009-11-01

    Full Text Available Home-based soft X-ray time-resolved scattering experiments with nanosecond time resolution (10 ns and nanometer spatial resolution were carried out at a table top soft X-ray plasma source (2.2–5.2 nm. The investigated system was the lyotropic liquid crystal C16E7/paraffin/glycerol/formamide/IR 5. Usually, major changes in physical, chemical, and/or optical properties of the sample occur as a result of structural changes and shrinking morphology. Here, these effects occur as a consequence of the energy absorption in the sample upon optical laser excitation in the IR regime. The liquid crystal shows changes in the structural response within few hundred nanoseconds showing a time decay of 182 ns. A decrease of the Bragg peak diffracted intensity of 30% and a coherent macroscopic movement of the Bragg reflection are found as a response to the optical pump. The Bragg reflection movement is established to be isotropic and diffusion controlled (1 μs. Structural processes are analyzed in the Patterson analysis framework of the time-varying diffraction peaks revealing that the inter-lamellar distance increases by 2.7 Å resulting in an elongation of the coherently expanding lamella crystallite. The present studies emphasize the possibility of applying TR-SXRD techniques for studying the mechanical dynamics of nanosystems.

  16. Real-time observation of epitaxial crystal growth in gaseous environment using x-ray diffraction and x-ray reflectometry

    International Nuclear Information System (INIS)

    Kawamura, Tomoaki; Bhunia, Satyaban; Watanabe, Yoshio; Fujikawa, Seiji

    2008-01-01

    We made the x-ray diffractometer combined with the MOCVD growth system for the real-time observation of epitaxial growth in gaseous environment, and investigated the growth mechanism of InP crystals. Changes of the (-5/2 O) Bragg diffraction during the growth revealed that the growth starts immediately after the In source has been supplied and gradually stopped, owing to the migrating In atoms on the surface. Additionally, one can easily determine the growth modes, including 3-dimensional mode, layer-by-layer mode, and step-flow mode, by observing the change of x-ray reflectivity with various growth conditions. (author)

  17. Time-Resolved X-Ray Diffraction: The Dynamics of the Chemical Bond

    DEFF Research Database (Denmark)

    Møller, Klaus Braagaard; Henriksen, Niels Engholm

    2012-01-01

    We review the basic theoretical formulation for pulsed X-ray scattering on nonstationary molecular states. Relevant time scales are discussed for coherent as well as incpherent X-ray pulses. The general formalism is applied to a nonstationary diatomic molecule in order to highlight the relation b...

  18. Two-dimensional time-resolved X-ray diffraction study of directional solidification in steels

    International Nuclear Information System (INIS)

    Yonemura, Mitsuharu

    2009-01-01

    Full text: The high intensity heat source used for fusion welding creates steep thermal gradients of 100 degree C/s from 1800 degree Celsius. Further, the influence of a preferred orientation is serious for observation of a directional solidification that follows the dendrite growth along the direction toward the moving heat source. Therefore, we observed the rapid solidification of weld metal at a time resolution of 0.01∼0.1seconds by the Two-Dimensional Time-Resolved X-ray Diffraction (2DTRXRD) system for real welding. The diffraction ring was dynamically observed by 2DTRXRD during arc-passing over the irradiation area of X-ray with synchrotron energy of 18 KeV. The arc power output was 10 V - 150 A, and a scan speed of the arc was 1.0 mm/s. The temperature rise of instruments was suppressed by the water-cooled copper plate under the sample. Further, the temperature distribution of the weld metal was measured by the thermocouple and related to the diffraction patterns. Consequently, solidification and solid phase transformation of low carbon steels and stainless steels were observed during rapid cooling by 2DTRXRD. In the low-carbon steel, the microstructure is formed in the 2 step process; (i) formation of crystallites and (ii) increase of crystallinity. In the stainless steel, the irregular interface layer of σ/y in the quenched metal after solidification is expected that it is easy for dendrites to move at the lower temperature. In the carbide precipitation stainless steel, it is easy for NbC to grow on σ phase with a little under cooling. Further, a mist-like pattern, which differs from the halo-pattern, in the fusion zone gave some indication of the possibilities to observe the nucleation and the early solidification by 2DTRXRD. (author)

  19. Developments in time-resolved high pressure x-ray diffraction using rapid compression and decompression

    International Nuclear Information System (INIS)

    Smith, Jesse S.; Sinogeikin, Stanislav V.; Lin, Chuanlong; Rod, Eric; Bai, Ligang; Shen, Guoyin

    2015-01-01

    Complementary advances in high pressure research apparatus and techniques make it possible to carry out time-resolved high pressure research using what would customarily be considered static high pressure apparatus. This work specifically explores time-resolved high pressure x-ray diffraction with rapid compression and/or decompression of a sample in a diamond anvil cell. Key aspects of the synchrotron beamline and ancillary equipment are presented, including source considerations, rapid (de)compression apparatus, high frequency imaging detectors, and software suitable for processing large volumes of data. A number of examples are presented, including fast equation of state measurements, compression rate dependent synthesis of metastable states in silicon and germanium, and ultrahigh compression rates using a piezoelectric driven diamond anvil cell

  20. Temperature gradient method for lipid phase diagram construction using time-resolved x-ray diffraction

    International Nuclear Information System (INIS)

    Caffrey, M.; Hing, F.S.

    1987-01-01

    A method that enables temperature-composition phase diagram construction at unprecedented rates is described and evaluated. The method involves establishing a known temperature gradient along the length of a metal rod. Samples of different compositions contained in long, thin-walled capillaries are positioned lengthwise on the rod and equilibrated such that the temperature gradient is communicated into the sample. The sample is then moved through a focused, monochromatic synchrotron-derived x-ray beam and the image-intensified diffraction pattern from the sample is recorded on videotape continuously in live-time as a function of position and, thus, temperature. The temperature at which the diffraction pattern changes corresponds to a phase boundary, and the phase(s) existing (coexisting) on either side of the boundary can be identified on the basis of the diffraction pattern. Repeating the measurement on samples covering the entire composition range completes the phase diagram. These additional samples can be conveniently placed at different locations around the perimeter of the cylindrical rod and rotated into position for diffraction measurement. Temperature-composition phase diagrams for the fully hydrated binary mixtures, dimyristoylphosphatidylcholine (DMPC)/dipalmitoylphosphatidylcholine (DPPC) and dipalmitoylphosphatidylethanolamine (DPPE)/DPPC, have been constructed using the new temperature gradient method. They agree well with and extend the results obtained by other techniques. In the DPPE/DPPC system structural parameters as a function of temperature in the various phases including the subgel phase are reported. The potential limitations of this steady-state method are discussed

  1. Submicron X-ray diffraction

    International Nuclear Information System (INIS)

    MacDowell, Alastair; Celestre, Richard; Tamura, Nobumichi; Spolenak, Ralph; Valek, Bryan; Brown, Walter; Bravman, John; Padmore, Howard; Batterman, Boris; Patel, Jamshed

    2000-01-01

    At the Advanced Light Source in Berkeley the authors have instrumented a beam line that is devoted exclusively to x-ray micro diffraction problems. By micro diffraction they mean those classes of problems in Physics and Materials Science that require x-ray beam sizes in the sub-micron range. The instrument is for instance, capable of probing a sub-micron size volume inside micron sized aluminum metal grains buried under a silicon dioxide insulating layer. The resulting Laue pattern is collected on a large area CCD detector and automatically indexed to yield the grain orientation and deviatoric (distortional) strain tensor of this sub-micron volume. A four-crystal monochromator is then inserted into the beam, which allows monochromatic light to illuminate the same part of the sample. Measurement of diffracted photon energy allows for the determination of d spacings. The combination of white and monochromatic beam measurements allow for the determination of the total strain/stress tensor (6 components) inside each sub-micron sized illuminated volume of the sample

  2. Short-time X-ray diffraction with an efficient-optimized, high repetition-rate laser-plasma X-ray-source

    International Nuclear Information System (INIS)

    Kaehle, Stephan

    2009-01-01

    This thesis deals with the production and application of ultrashort X-ray pulses. In the beginning different possibilities for the production of X-ray pulses with pulse durations of below one picosecond are presented, whereby the main topic lies on the so called laser-plasma X-ray sources with high repetition rate. In this case ultrashort laser pulses are focused on a metal, so that in the focus intensities of above 10 16 W/cm 2 dominate. In the ideal case in such way ultrafast electrons are produced, which are responsible for line radiation. In these experiments titanium K α radiation is produced, thes photons possess an energy of 4.51 keV. For the efficient production of line radiation here the Ti:Sa laser is optimized in view of the laser energy and the pulse shape and the influence of the different parameters on the K α production systematically studied. The influences of laser intensity, system-conditioned pre-pulses and of phase modulation are checked. It turns out that beside the increasement of the K α radiation by a suited laser intensity a reduction of the X-ray background radiation is of deciding importance for the obtaining of clear diffraction images. This background radiation is mainly composed of bremsstrahlung. It can be suppressed by the avoidance of intrinsic pre-pulses and by means of 2nd-order phase modulation. By means of optical excitation and X-ray exploration experiments the production of acoustic waves after ultrashort optical excitation in a 150 nm thick Ge(111) film on Si(111) is studied. These acoustic waves are driven by thermal (in this time scale time-independent) and electronic (time dependent) pressure amounts. As essential results it turns out that the relative amount of the electronic pressure increases with decreasing excitation density [de

  3. Diffractive X-Ray Telescopes

    International Nuclear Information System (INIS)

    Skinner, G.K.; Skinner, G.K

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro arc seconds or even better, that would allow, for example, imaging of the distorted spacetime in the immediate vicinity of the supermassive black holes in the center of active galaxies What then is precluding their immediate adoption Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed atmospheric absorption

  4. Time-resolved x-ray diffraction measurement of C60 under high pressure and temperature using synchrotron radiation

    International Nuclear Information System (INIS)

    Horikawa, T; Suito, K; Kobayashi, M; Onodera, A

    2002-01-01

    C 60 has been studied by means of time-resolved x-ray diffraction measurements using synchrotron radiation. Diffraction patterns were recorded at intervals of 1-10 min for samples under high pressure (12.5 and 14.3 GPa) and high temperature (up to 800 deg. C) for, at the longest, 3 h. Time, pressure, and temperature dependences of the C 60 structure are presented and the relevance to the hardness of materials derived from C 60 is discussed

  5. Probing Photoinduced Structural Phase Transitions by Fast or Ultra-Fast Time-Resolved X-Ray Diffraction

    Science.gov (United States)

    Cailleau, Hervé Collet, Eric; Buron-Le Cointe, Marylise; Lemée-Cailleau, Marie-Hélène Koshihara, Shin-Ya

    A new frontier in the field of structural science is the emergence of the fast and ultra-fast X-ray science. Recent developments in time-resolved X-ray diffraction promise direct access to the dynamics of electronic, atomic and molecular motions in condensed matter triggered by a pulsed laser irradiation, i.e. to record "molecular movies" during the transformation of matter initiated by light pulse. These laser pump and X-ray probe techniques now provide an outstanding opportunity for the direct observation of a photoinduced structural phase transition as it takes place. The use of X-ray short-pulse of about 100ps around third-generation synchrotron sources allows structural investigations of fast photoinduced processes. Other new X-ray sources, such as laser-produced plasma ones, generate ultra-short pulses down to 100 fs. This opens the way to femtosecond X-ray crystallography, but with rather low X-ray intensities and more limited experimental possibilities at present. However this new ultra-fast science rapidly progresses around these sources and new large-scale projects exist. It is the aim of this contribution to overview the state of art and the perspectives of fast and ultra-fast X-ray scattering techniques to study photoinduced phase transitions (here, the word ultra-fast is used for sub-picosecond time resolution). In particular we would like to largely present the contribution of crystallographic methods in comparison with optical methods, such as pump-probe reflectivity measurements, the reader being not necessary familiar with X-ray scattering. Thus we want to present which type of physical information can be obtained from the positions of the Bragg peaks, their intensity and their shape, as well as from the diffuse scattering beyond Bragg peaks. An important physical feature is to take into consideration the difference in nature between a photoinduced phase transition and conventional homogeneous photoinduced chemical or biochemical processes where

  6. Aqueous Nucleation and Growth of Titanium Oxides Using Time-Resolved Synchrotron X- ray Diffraction

    Science.gov (United States)

    Hummer, D. R.; Heaney, P. J.; Post, J. E.

    2006-05-01

    The inorganic precipitation of oxide minerals in soil environments has profound effects on a variety of geochemical processes. These include the removal of metals from the aqueous phase, the production of coatings that reduce the reactive surface area of pre-existing mineral grains, and the generation of feedstocks for microbial metabolic reactions. Recent observations of transient, metastable phases during the growth of oxide crystallites has raised questions about their role in crystallization mechanisms, and created a need for more detailed structural measurements. To better understand the process of nucleation and growth, we investigated the crystallization of Ti oxides from aqueous 0.5 M TiCl4 solutions using synchrotron X-ray diffraction at temperatures of 100 and 150 °C. Solutions were heated in a 1.0 mm internal diameter quartz glass capillary sealed with epoxy. Powder diffraction patterns of the growing crystallites were collected using image plate technology with a time step of ~ 4 minutes, providing high resolution in situ measurements of structural changes during the crystallization process. The data indicate a co-precipitation of the two crystalline phases anatase and rutile within the first 30 minutes of heating, followed by a gradual phase transition from anatase to rutile during particle coarsening throughout the 10 hour duration of an experiment. The co-existence of anatase and rutile at the onset of crystallization lends additional support to the assertion of nearly identical free energies for anatase and rutile at the nanoscale, believed to be due to the prominence of surface energy effects (Ranade et al., 2001). Whole pattern analyses using the Rietveld refinement method also documented previously unobserved changes in lattice parameters of both phases during growth, on the order of 0.2-0.3 % expansion for each axis. The trends in lattice parameters are observed to be temperature dependent, generally having lower values at higher

  7. Diffracted X-ray tracking: new system for single molecular detection with X-rays

    CERN Document Server

    Sasaki, Y C; Adachi, S; Suzuki, Y; Yagi, N

    2001-01-01

    We propose a new X-ray methodology for direct observations of the behaviors of single molecular units in real time and real space. This new system, which we call Diffracted X-ray Tracking (DXT), monitors the Brownian motions of a single molecular unit by observations of X-ray diffracted spots from a nanocrystal, tightly bound to the individual single molecular unit in bio-systems. DXT does not determine any translational movements, but only orientational movements.

  8. Diffracted X-ray tracking: new system for single molecular detection with X-rays

    International Nuclear Information System (INIS)

    Sasaki, Y.C.; Okumura, Y.; Adachi, S.; Suzuki, Y.; Yagi, N.

    2001-01-01

    We propose a new X-ray methodology for direct observations of the behaviors of single molecular units in real time and real space. This new system, which we call Diffracted X-ray Tracking (DXT), monitors the Brownian motions of a single molecular unit by observations of X-ray diffracted spots from a nanocrystal, tightly bound to the individual single molecular unit in bio-systems. DXT does not determine any translational movements, but only orientational movements

  9. X-ray topography and multiple diffraction

    International Nuclear Information System (INIS)

    Chang, S.-L.

    1983-01-01

    A short summary on X-ray topography, which is based on the dynamical theory of X-ray diffraction, is made. The applications and properties related to the use of the multiple diffraction technique are analized and discussed. (L.C.) [pt

  10. Strategies for Time-resolved X-ray Diffraction of Phase Transitions with Laser Compression

    Science.gov (United States)

    Benedetti, Laura Robin; Eggert, J. H.; Bradley, D. K.; Bell, P. M.; Kilkenny, J. D.; Palmer, N.; Petre, R. B.; Rygg, J. R.; Sorce, C.; Collins, G. W.; Boehly, T. R.

    2017-10-01

    As part of a program to document kinetics of phase transitions under laser-driven dynamic compression, we are designing a platform to make multiple x-ray diffraction measurements during a single laser experiment. Our plans include experimental development at Omega-EP and eventual implementation at NIF. We will present our strategy for designing a robust platform that can effectively document a wide variety of phase transformations by utilizing both streaked and multiple-frame imaging detectors. Preliminary designs utilize a novel CMOS detector designed by Sandia National Lab. Our initial experiments include scoping studies that will focus on photometrics and shielding requirements in the high EMP environment close to the target. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. Lawrence Livermore National Security, LLC, LLNL-ABS-734470.

  11. Kinetics of the main phase transition of hydrated lecithin monitored by real-time x-ray diffraction

    International Nuclear Information System (INIS)

    Caffrey, M.; Bilderback, D.H.

    1984-01-01

    A method is described for observing and recording in real-time x-ray diffraction from an unoriented hydrated membrane lipid, dipalmitoylphosphatidylcholine (DPPC), through its thermotropic gel/liquid crystal phase transition. Synchrotron radiation from the Cornell High Energy Synchrotron Source (Ithaca, New York) was used as an x-ray source of extremely high brilliance and the dynamic display of the diffraction image was effected using a three-stage image intensifier tube coupled to an external fluorescent screen. The image on the output phosphor was sufficiently intense to be recorded cinematographically and to be displayed on a television monitor using a vidicon camera at 30 frames x s -1 . These measurements set an upper limit of 2 s on the DPPC gel → liquid crystal phase transition and indicate that the transition is a two-state process. The real-time method couples the power of x-ray diffraction as a structural probe with the ability to follow kinetics of structural changes. The method does not require an exogenous probe, is relatively nonperturbing, and can be used with membranes in a variety of physical states and with unstable samples. The method has the additional advantage over its static measurement counterpart in that it is more likely to detect transiently stable intermediates if present

  12. X-ray diffraction 2 - diffraction principles

    International Nuclear Information System (INIS)

    O'Connor, B.

    1999-01-01

    Full text: The computation of powder diffraction intensities is based on the principle that the powder pattern comprises the summation of the intensity contributions from each of the crystallites (or single crystals) in the material. Therefore, it is of value for powder diffractionists to appreciate the form of the expression for calculating single crystal diffraction pattern intensities. This knowledge is especially important for Rietveld analysis practitioners in terms of the (i) mathematics of the method and (ii) retrieving single crystal structure data from the literature. We consider the integrated intensity from a small single crystal being rotated at velocity ω through the Bragg angle θ for reflection (hkl).... I(hkl) = [l o /ω]. [e 4 /m 2 c 4 ]. [λ 3 δV F(hkl) 2 /υ 2 ].[(1+cos 2 2θ)/2sin2θ] where e, m and c are the usual fundamental constants; λ is the x-ray wavelength, δV is the crystallite volume; F(hkl) is the structure factor; υ is the unit cell volume; and (1+cos 2 θ)/2sin2θ] is the Lorentz-polarisation factor for an unpolarised incident beam. The expression does not include a contribution for extinction. The influence of factors λ, δV, F(hkl) and υ on the intensities should be appreciated by powder diffractionists, especially the structure factor, F(hkl), which is responsible for the fingerprint nature of diffraction patterns, such as the rise and fall of intensity from peak to peak. The structure factor expression represents the summation of the scattered waves from each of the j scattering centres (i e atoms) in the unit cell: F(hkl) Σ f j exp[2πi (h.x j +k.y i +l. z i )] T j . Symbol f is the scattering factor (representing the atom-type scattering efficiency); (x, y, z) are the fractional position coordinates of atom j within the unit cell; and T is the thermal vibration factor for the atom given by: T j = 8π 2 2 > sin 2 θ/λ 2 with 2 > being the mean-square vibration amplitude of the atom (assumed to be isotropic). The

  13. Two-dimensional x-ray diffraction

    CERN Document Server

    He, Bob B

    2009-01-01

    Written by one of the pioneers of 2D X-Ray Diffraction, this useful guide covers the fundamentals, experimental methods and applications of two-dimensional x-ray diffraction, including geometry convention, x-ray source and optics, two-dimensional detectors, diffraction data interpretation, and configurations for various applications, such as phase identification, texture, stress, microstructure analysis, crystallinity, thin film analysis and combinatorial screening. Experimental examples in materials research, pharmaceuticals, and forensics are also given. This presents a key resource to resea

  14. The Oxford-Diamond In Situ Cell for studying chemical reactions using time-resolved X-ray diffraction

    Science.gov (United States)

    Moorhouse, Saul J.; Vranješ, Nenad; Jupe, Andrew; Drakopoulos, Michael; O'Hare, Dermot

    2012-08-01

    A versatile, infrared-heated, chemical reaction cell has been assembled and commissioned for the in situ study of a range of chemical syntheses using time-resolved energy-dispersive X-ray diffraction (EDXRD) on Beamline I12 at the Diamond Light Source. Specialized reactor configurations have been constructed to enable in situ EDXRD investigation of samples under non-ambient conditions. Chemical reactions can be studied using a range of sample vessels such as alumina crucibles, steel hydrothermal autoclaves, and glassy carbon tubes, at temperatures up to 1200 °C.

  15. Diffraction enhanced x-ray imaging

    International Nuclear Information System (INIS)

    Thomlinson, W.; Zhong, Z.; Johnston, R.E.; Sayers, D.

    1997-09-01

    Diffraction enhanced imaging (DEI) is a new x-ray radiographic imaging modality using synchrotron x-rays which produces images of thick absorbing objects that are almost completely free of scatter. They show dramatically improved contrast over standard imaging applied to the same phantoms. The contrast is based not only on attenuation but also the refraction and diffraction properties of the sample. The diffraction component and the apparent absorption component (absorption plus extinction contrast) can each be determined independently. This imaging method may improve the image quality for medical applications such as mammography

  16. Mesoscopic structural phase progression in photo-excited VO2 revealed by time-resolved x-ray diffraction microscopy

    Science.gov (United States)

    Zhu, Yi; Cai, Zhonghou; Chen, Pice; Zhang, Qingteng; Highland, Matthew J.; Jung, Il Woong; Walko, Donald A.; Dufresne, Eric M.; Jeong, Jaewoo; Samant, Mahesh G.; Parkin, Stuart S. P.; Freeland, John W.; Evans, Paul G.; Wen, Haidan

    2016-02-01

    Dynamical phase separation during a solid-solid phase transition poses a challenge for understanding the fundamental processes in correlated materials. Critical information underlying a phase transition, such as localized phase competition, is difficult to reveal by measurements that are spatially averaged over many phase separated regions. The ability to simultaneously track the spatial and temporal evolution of such systems is essential to understanding mesoscopic processes during a phase transition. Using state-of-the-art time-resolved hard x-ray diffraction microscopy, we directly visualize the structural phase progression in a VO2 film upon photoexcitation. Following a homogenous in-plane optical excitation, the phase transformation is initiated at discrete sites and completed by the growth of one lattice structure into the other, instead of a simultaneous isotropic lattice symmetry change. The time-dependent x-ray diffraction spatial maps show that the in-plane phase progression in laser-superheated VO2 is via a displacive lattice transformation as a result of relaxation from an excited monoclinic phase into a rutile phase. The speed of the phase front progression is quantitatively measured, and is faster than the process driven by in-plane thermal diffusion but slower than the sound speed in VO2. The direct visualization of localized structural changes in the time domain opens a new avenue to study mesoscopic processes in driven systems.

  17. Time-resolved x-ray diffraction analysis of the experimental dehydration of serpentine at high pressure

    International Nuclear Information System (INIS)

    Inoue, Toru; Yoshimi, Isamu; Yamada, Akihiro; Kikegawa, Takumi

    2009-01-01

    Time-resolved, in situ X-ray diffraction analysis was used to determine the dehydration rate and kinetics of serpentine during experimental dehydration at high pressures. The capsule used comprises a diamond sleeve fitted with Au or Pt lids in order to provide high-quality, time-resolved X-ray diffraction data. Antigorite quickly dehydrated to enstatite + forsterite + fluid within 2 h at 650degC below ∼6 GPa. Avrami modeling of the results and SEM observations of the partially dehydrated sample revealed that the nucleation rate was quite high for enstatite but low for forsterite, showing incubation periods of ∼10 min before appearing. The crystallization of these minerals is controlled largely by the composition of the fluid generated from serpentine dehydration. The dehydration boundary determined below 6 GPa in the present study is consistent with the results of previous phase equilibrium studies. This study indicates that serpentine in a subducting slab dehydrates rapidly below 6 GPa when the slab intersects the dehydration boundary conditions. (author)

  18. Diffractive sub-picosecond manipulation of x-rays

    International Nuclear Information System (INIS)

    Adams, B.

    2004-01-01

    A class of X-ray optical elements for the sub-picosecond manipulation of X-rays is proposed. The design of these elements is based upon a time-dependent dynamical diffraction theory that synthesizes the eikonal theory with the Takagi-Taupin theory. A brief outline of the theory is given

  19. X-ray filter for x-ray powder diffraction

    Science.gov (United States)

    Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.; Dooryhee, Eric; Ghose, Sanjit

    2018-01-23

    Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and walls defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.

  20. Two-dimensional time-resolved x-ray diffraction study of dual phase rapid solidification in steels

    Science.gov (United States)

    Yonemura, Mitsuharu; Osuki, Takahiro; Terasaki, Hidenori; Komizo, Yuichi; Sato, Masugu; Toyokawa, Hidenori; Nozaki, Akiko

    2010-01-01

    The high intensity heat source used for fusion welding creates steep thermal gradients of 100 °C/s from 1800 °C. Further, the influence of preferred orientation is important for the observation of a directional solidification that follows the dendrite growth along the ⟨100⟩ direction toward the moving heat source. In the present study, we observed the rapid solidification of weld metal at a time resolution of 0.01-0.1 s by a two-dimensional time-resolved x-ray diffraction (2DTRXRD) system for real welding. The diffraction rings were dynamically observed by 2DTRXRD with synchrotron energy of 18 keV while the arc passes over the irradiation area of the x-rays. The arc power output was 10 V-150 A, and the scan speed of the arc was 1.0 mm/s. The temperature rise in instruments was suppressed by a water-cooled copper plate under the specimen. Further, the temperature distribution of the weld metal was measured by a thermocouple and correlated with the diffraction patterns. Consequently, solidification and solid phase transformation of low carbon steels and stainless steels were observed during rapid cooling by 2DTRXRD. In the low carbon steel, the microstructure is formed in a two step process, (i) formation of crystallites and (ii) increase of crystallinity. In stainless steel, the irregular interface layer of δ/γ in the quenched metal after solidification is expected to show the easy movement of dendrites at a lower temperature. In carbide precipitation stainless steel, it is easy for NbC to grow on δ phase with a little undercooling. Further, a mistlike pattern, which differs from the halo pattern, in the fusion zone gave some indication of the possibilities to observe the nucleation and the early solidification by 2DTRXRD.

  1. Time-resolved X-ray diffraction studies of laser-induced acoustic wave propagation in bilayer metallic thin crystals

    Energy Technology Data Exchange (ETDEWEB)

    Er, Ali Oguz [Department of Physics and Astronomy, Western Kentucky University, Bowling Green, Kentucky 42101 (United States); Tang, Jau, E-mail: jautang@gate.sinica.edu.tw, E-mail: prentzepis@ece.tamu.edu [Research Center for Applied Sciences Academia Sinica, Taipei, Taiwan (China); Chen, Jie [Key Laboratory for Laser Plasmas (Ministry of Education) and Department of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); Rentzepis, Peter M., E-mail: jautang@gate.sinica.edu.tw, E-mail: prentzepis@ece.tamu.edu [Department of Electrical and Computer Engineering, Texas A and M University, College Station, Texas 77843 (United States)

    2014-09-07

    Phonon propagation across the interface of a Cu/Ag(111) bilayer and transient lattice disorder, induced by a femtosecond 267 nm pulse, in Ag(111) crystal have been measured by means of time resolved X-ray diffraction. A “blast” force due to thermal stress induced by suddenly heated electrons is formed within two picoseconds after excitation and its “blast wave” propagation through the interface and Ag (111) crystal was monitored by the shift and broadening of the rocking curve, I vs. ω, as a function of time after excitation. Lattice disorder, contraction and expansion as well as thermal strain formation and wave propagation have also been measured. The experimental data and mechanism proposed are supported by theoretical simulations.

  2. X-ray diffraction identification of clay minerals by microcomputer

    International Nuclear Information System (INIS)

    Rodrigues, S.; Imasava, F.J.

    1988-01-01

    The identification of clay minerals by X-ray powder diffraction are done by searching an unknown pattern with a file of standard X-ray diffraction patterns. For this searching done by hand is necessary a long time. This paper shows a program in ''Basic'' language to be utilized in microcomputers for the math of the unknown pattern, using the high velocity of comparison of the microcomputer. A few minutes are used for the match. (author) [pt

  3. Characterization of x-ray diffraction and electron spin resonance: Effects of sintering time and temperature on bovine hydroxyapatite

    International Nuclear Information System (INIS)

    Kusrini, Eny; Sontang, Muhammad

    2012-01-01

    The physical and chemical properties of a hydroxyapatite produced by the sintering of bovine bone were investigated by powder x-ray diffraction (PXRD), electron spin resonance (ESR), energy dispersive x-ray spectroscopy (EDX), scanning electron microscopy (SEM), Fourier transform infrared (FTIR), and differential thermal analysis (DTA). A bovine bone powder was sintered at different temperatures ranging from 500 to 1400 °C. The influences of post-irradiation storage on the radiation ESR response of the bovine bone powder before and after sintering were also studied. The results indicate that the sintered bovine bone powder contained hydroxyapatite. Diffraction patterns were sharp and clear based on the (211), (300), and (202) reflections corresponding to bovine hydroxyapatite (BHA), which confirmed the phase purity and high crystalline grade of the BHA produced. The PXRD profile of BHA was dependent on sintering temperatures and times. The molecular formula of BHA was determined by Rietveld analysis showed a similar structure and composition to calcium hydroxyapatite in hexagonal P6 3 /m space group a=b=9.435 Å and c=6.895 Å. ESR data showed that the sintering process can decrease the number of free radicals in BHA; it also revealed that the number of free radicals is constant during long storage periods (75 days). The sintering technique described in this study may be used to extract hydroxyapatite from biowaste bovine bone, leading to its application as a bone filler. - Highlights: ► Natural hydroxyapatite was produced from the bio-wasting bovine bones by sintering method. ► PXRD profile of BHA is dependent on the different temperatures and times in sintering process. ► ESR data is useful to study the typical of free radicals formed in the samples after irradiation. ► Stability and physicochemical properties of BHA is dependent on the different storage times. ► Technique is able to be used to find the natural hydroxyapatite applicable for bone filler.

  4. Systematic investigation of lard polymorphism using combined DSC and time-resolved synchrotron X-ray diffraction

    NARCIS (Netherlands)

    Kalnin, D.J.E.; Lesieur, P.; Artzner, F.; Keller, G.; Ollivon, M.

    2005-01-01

    The polymorphic behavior of lard was systematically investigated by differential scanning calorimetry (DSC) while simultaneously monitoring the formation of the different crystal forms with X-ray diffraction (XRDT). To interpret the complex polymorphic evolution of the sample analyzed by regular

  5. CCD-based X-ray detectors for X-ray diffraction studies

    International Nuclear Information System (INIS)

    Ito, K.; Amemiya, Y.

    1999-01-01

    CCD-based X-ray detectors are getting to be used for X-ray diffraction studies especially in the studies where real time (automated) measurements and time-resolved measurements are required. Principles and designs of two typical types of CCD-based detectors are described; one is ths system in which x-ray image intensifiers are coupled to maximize the detective quantum efficiency for time-resolved measurements, and the other is the system in which tapered optical fibers are coupled for the reduction of the image into the CCD, which is optimized for automated measurements for protein crystallography. These CCD-based X-ray detectors have an image distortion and non-uniformity of response to be corrected by software. Correction schemes which we have developed are also described. (author)

  6. X-ray diffraction device comprising cooling medium connections provided on the x-ray tube

    NARCIS (Netherlands)

    1996-01-01

    An X-ray diffraction device comprises a water-cooled X-ray tube which exhibits a line focus as well as, after rotation through 90 DEG , a point focus. Contrary to customary X-ray tubes, the cooling water is not supplied via the housing (12) in which the X-ray tube is mounted, but the cooling water

  7. Polarisation resonance in X-ray diffraction

    International Nuclear Information System (INIS)

    Goodman, P.; Paterson, D.; Matheson, S.

    1994-01-01

    The study of crystal structures by means of dynamic X-ray diffraction has placed a challenge to theoreticians to revise the X-ray diffraction theory based on Maxwell's equation. In this paper the feasibility of using 'polarisation resonance' as a tool in the determination of absolute configuration for asymmetric structures is investigated. Two (left- and right-handed), σ + and σ- , circular polarization states for 3-beam conditions are considered. Moreover, extending interaction into the 3 rd. dimension (normal to the beam) opens the possibility of absolute configuration determination of asymmetric structures in 3 dimensions. The computational scheme used is shown in terms of scattering diagrams. 7 refs., 1 tab., 6 figs

  8. Basic of X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Giacovazzo, C [Bari Univ. (Italy). Dip. Geomineralogico

    1996-09-01

    The basic concepts of X-ray diffraction may be more easily understood if it is made preliminary use of a mathematical background. In these pages the authors will first define the delta function and its use for the representation of a lattice. Then the concepts of Fourier transform and convolution are given. At the end of this talk one should realize that a crystal is the convolution of the lattice with a function representing the content of the unit cell.

  9. Basic of X-ray diffraction

    International Nuclear Information System (INIS)

    Giacovazzo, C.

    1996-01-01

    The basic concepts of X-ray diffraction may be more easily understood if it is made preliminary use of a mathematical background. In these pages the authors will first define the delta function and its use for the representation of a lattice. Then the concepts of Fourier transform and convolution are given. At the end of this talk one should realize that a crystal is the convolution of the lattice with a function representing the content of the unit cell

  10. Application of combined multivariate techniques for the description of time-resolved powder X-ray diffraction data

    Czech Academy of Sciences Publication Activity Database

    Taris, A.; Grosso, M.; Brundu, M.; Guida, V.; Viani, Alberto

    2017-01-01

    Roč. 50, č. 2 (2017), s. 451-461 ISSN 1600-5767 R&D Projects: GA MŠk(CZ) LO1219 Keywords : in situ X-ray powder diffraction * amorphous content * chemically bonded ceramic s * statistical total correlation spectroscopy * multivariate curve resolution Subject RIV: JJ - Other Materials OBOR OECD: Materials engineering Impact factor: 2.495, year: 2016 http://journals.iucr.org/j/issues/2017/02/00/ap5006/index.html

  11. Glancing angle synchrotron X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Cernik, R J [Daresbury Lab., Warrington, WA (United States)

    1996-09-01

    This paper describes in basic detail some of the techniques that can be used to study thin films and surfaces. These are all in the X-ray region and cover reflectivity, diffraction form polycrystalline films, textured films and single crystal films. Other effects such as fluorescence and diffuse scattering are mentioned but not discussed in detail. Two examples of the reflectivity from multilayers and the diffraction from iron oxide films are discussed. The advantages of the synchrotron for these studies is stressed and the experimental geometries that can be employed are described i detail. A brief bibliography is provided at the end to accompany this part of the 1996 Frascati school.

  12. X-ray diffraction and chemical bonding

    International Nuclear Information System (INIS)

    Bats, J.W.

    1976-01-01

    Chemical bonds are investigated in sulfamic acid (H 3 N-SO 3 ), sodium sulfonlate dihydrate (H 2 NC 6 H 4 SO 3 Na.2H 2 O), 2,5-dimercaptothiadiazole (HS-C 2 N 2 S-SH), sodium cyanide dihydrate (NaCN.2H 2 O), sodium thiocyanate (NaSCN) and ammonium thiocyanate (NH 4 SCN) by X-ray diffraction, and if necessary completed with neutron diffraction. Crystal structures and electron densities are determined together with bond length and angles. Also the effects of thermal motion are discussed

  13. Glancing angle synchrotron X-ray diffraction

    International Nuclear Information System (INIS)

    Cernik, R.J.

    1996-01-01

    This paper describes in basic detail some of the techniques that can be used to study thin films and surfaces. These are all in the X-ray region and cover reflectivity, diffraction form polycrystalline films, textured films and single crystal films. Other effects such as fluorescence and diffuse scattering are mentioned but not discussed in detail. Two examples of the reflectivity from multilayers and the diffraction from iron oxide films are discussed. The advantages of the synchrotron for these studies is stressed and the experimental geometries that can be employed are described i detail. A brief bibliography is provided at the end to accompany this part of the 1996 Frascati school

  14. Development of a fast pixel array detector for use in microsecond time-resolved x-ray diffraction

    International Nuclear Information System (INIS)

    Barna, S.L.; Gruner, S.M.; Shepherd, J.A.

    1995-01-01

    A large-area pixel x-ray detector is being developed to collect eight successive frames of wide dynamic range two-dimensional images at 200kHz rates. Such a detector, in conjunction with a synchrotron radiation x-ray source, will enable time-resolved x-ray studies of proteins and other materials on time scales which have previously been inaccessible. The detector will consist of an array of fully-depleted 150 micron square diodes connected to a CMOS integrated electronics layer with solder bump-bonding. During each framing period, the current resulting from the x-rays stopped in the diodes is integrated in the electronics layer, and then stored in one of eight storage capacitors underneath the pixel. After the last frame, the capacitors are read out at standard data transmission rates. The detector has been designed for a well-depth of at least 10,000 x-rays (at 20keV), and a noise level of one x-ray. Ultimately, the authors intend to construct a detector with over one million pixels (1024 by 1024). They present the results of their development effort and various features of the design. The electronics design is discussed, with special attention to the performance requirements. The choice and design of the detective diodes, as they relate to x-ray stopping power and charge collection, are presented. An analysis of various methods of bump bonding is also presented. Finally, the authors discuss the possible need for a radiation-blocking layer, to be placed between the electronics and the detective layer, and various methods they have pursued in the construction of such a layer

  15. X-radiation damage of hydrated lecithin membranes detected by real-time X-ray diffraction using wiggler-enhanced synchrotron radiation as the ionizing radiation source

    International Nuclear Information System (INIS)

    Caffrey, M.; Cornell Univ., Ithaca, NY

    1984-01-01

    Radiation damage of hydrated lecithin membranes brought about by exposure to wiggler-derived synchrotron radiation at 8.3 keV (1.5 A) is reported. Considerable damage was observed with exposures under 1 h at an incident flux density of 3 x 10 10 photons s -1 mm -2 , corresponding to a cumulative radiation dose of <= 10 MRad. Damage was so dramatic as to be initially observed while making real-time X-ray diffraction measurements on the sample. The damaging effects of 8.3 keV X-rays on dispersions of dipalmitoyllecithin and lecithin derived from hen egg yolk are as follows: (1) marked changes were noted in the X-ray diffraction behaviour, indicating disruption of membrane stacking. (2) Chemical breakdown of lecithin was observed. (3) The X-ray beam visibly damaged the sample and changed the appearance of the lipid dispersion, when viewed under the light microscope. Considering the importance of X-ray diffraction as a structural probe and the anticipated use of synchrotron radiation in studies involving membranes, the problem of radiation damage must be duly recognized. Furthermore, since dipalmitoyllecithin, the major lipid used in the present study, is a relatively stable compound, it is not unreasonable to expect that X-ray damage may be a problem with other less stable biological and non-biological materials. These results serve to emphasize that whenever a high intensity X-ray source is used, radiation damage can be a problem and that the sensitivity of the sample must always be evaluated under the conditions of measurement. (orig.)

  16. Time-resolved x-ray diffraction from frog skeletal muscle during an isotonic twitch under a small load

    International Nuclear Information System (INIS)

    Sugi, Haruo; Amemiya, Yoshiyuki; Hashizume, Hiroo.

    1978-01-01

    A time-resolved x-ray diffraction technique was used to study the time course of change in the intensity ratio Isub(1,0)/Isub(1,1) during isotonic twitch (initial sarcomere, 2.4 μm) under a small load and to determine the kinetic properties of the crossbridges responsible for muscle contraction. Isotonic twitches in four other preparations with an initial sarcomere of 2.4 μm and in two with an initial sarcomere of 2.3 μm and 2.2 μm, respectively, were examined. In each case, the intensity ratio started to decrease at stimulation, reached a minimum value of 0.8 - 1.0 within the first 20 - 30% of the shortening phase, and maintained this value until the beginning of the relaxation phase. Gradual recovery of the intensity ratio to the resting value was seen during the relaxation phase. During the recovery phase, the intensity ratio appeared to exhibit oscillatory changes. Though the extent of shortening was reduced by about 30% at the end of each experiment, the duration of the shortening phase remained almost unchanged in all the preparations examined. The time course of change in the intensity ratio was also examined during an isometric twitch in four preparations (sarcomere, 2.4 μm) with the tibial end connected to a strain gauge. The extent of internal shortening of muscle fibres against the tendons and the recording system during an isometric twitch or a tetanus at low temperatures was estimated. The intensity ratio decreased to a minimum value of 0.5 - 0.6 during the rising phase of isometric tension and started to return to the resting value after the beginning of relaxation. In both isotonic and isometric twitches, a decrease in the intensity ratio resulted from both a decrease in the 1,0 intensity and an increase in the 1,1 intensity. (J.P.N.)

  17. X-Ray Diffraction Project Final Report, Fiscal Year 2006

    International Nuclear Information System (INIS)

    Dane V. Morgan

    2006-01-01

    An x-ray diffraction diagnostic system was developed for determining real-time shock-driven lattice parameter shifts in single crystals at the gas gun at TA-IV at Sandia National Laboratories (SNL). The signal-to-noise ratio and resolution of the system were measured using imaging plates as the detector and by varying the slit width. This report includes tests of the x-ray diffraction system using a phosphor coupled to a charge-coupled device (CCD) camera by a coherent fiber-optic bundle. The system timing delay was measured with a newly installed transistor-transistor logic (TTL) bypass designed to reduce the x-ray delay time. The axial misalignment of the Bragg planes was determined with respect to the optical axis for a set of eight LiF [lithium fluoride] crystals provided by SNL to determine their suitability for gas gun experiments

  18. Structural changes during contraction in vertebrate skeletal muscle as studied by time-resolved X-ray diffraction technique

    International Nuclear Information System (INIS)

    Sugi, H.; Tanaka, H.; Kobayashi, T.; Iwamoto, H.; Wakabayashi, K.; Hamanaka, T.; Mitsui, T.; Amemiya, Y.

    1986-01-01

    To obtain information about the structural changes in vertebrate skeletal muscle during contraction, time-resolved X-ray diffraction studies were performed on the intensity changes of the 59 A and 51 A actin layer lines from bullfrog sartorius muscle during the isometric force development, and the intensity changes of the 143 A and 215 A myosin meridional reflections and of the 1,0 and 1,1 equatorial reflections when isometrically contracting muscle was subjected to sinusoidal length changes (1%, 5-10Hz) with the following results. The integrated intensities of the 59 A and 51 A actin layer lines increased during the force development by 30-50% for the 59 A reflection, and by about 70% for the 51 A reflection compard to their respective resting values. These intensity changes were greater than those taking place during the transition from rest to rigor state, and observed to precede the intensity changes of the 429 A myosin off-meridional reflection and of equatorial reflections. When sinusoidal length changes were applied to the muscle generating steady isometric force, the resulting periodic intensity changes in the 1,0 and 1,1 equatorial reflections were in phase and in antiphase with the length changes, respectively. On the other hand, the 143 A myosin reflection exhibited a characteristic periodic change; its intensity reached a maximum at each boundary between the stretch and release phases of the length changes. These results are discussed in connection with the behavior of the cross-bridges during contraction. (author)

  19. X-ray diffraction imaging of material microstructures

    KAUST Repository

    Varga, Laszlo

    2016-10-20

    Various examples are provided for x-ray imaging of the microstructure of materials. In one example, a system for non-destructive material testing includes an x-ray source configured to generate a beam spot on a test item; a grid detector configured to receive x- rays diffracted from the test object; and a computing device configured to determine a microstructure image based at least in part upon a diffraction pattern of the x-rays diffracted from the test object. In another example, a method for determining a microstructure of a material includes illuminating a beam spot on the material with a beam of incident x-rays; detecting, with a grid detector, x-rays diffracted from the material; and determining, by a computing device, a microstructure image based at least in part upon a diffraction pattern of the x-rays diffracted from the material.

  20. Time resolved X-ray micro-diffraction measurements of the dynamic local layer response to electric field in antiferroelectric liquid crystals

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Yumiko; Iida, Atuso E-mail: atsuo.iida@kek.jp; Takanishi, Yoichi; Ogasawara, Toyokazu; Takezoe, Hideo

    2001-07-21

    The time-resolved synchrotron X-ray microbeam diffraction experiment has been carried out to reveal the local layer response to the electric field in the antiferroelectric liquid crystal. The X-ray microbeam of a few {mu}m spatial resolution was obtained with Kirkpatrick-Baez optics. The time-resolved small angle diffraction experiment was performed with a time resolution ranging from 10 {mu}s to a few ms. The reversible local layer change between the horizontal chevron and the quasi-bookshelf structure was confirmed by the triangular wave form. The transient layer response for the step form electric field was observed. The layer response closely related with an electric field induced antiferroelectric to ferroelectric phase transition.

  1. Time resolved X-ray micro-diffraction measurements of the dynamic local layer response to electric field in antiferroelectric liquid crystals

    International Nuclear Information System (INIS)

    Takahashi, Yumiko; Iida, Atuso; Takanishi, Yoichi; Ogasawara, Toyokazu; Takezoe, Hideo

    2001-01-01

    The time-resolved synchrotron X-ray microbeam diffraction experiment has been carried out to reveal the local layer response to the electric field in the antiferroelectric liquid crystal. The X-ray microbeam of a few μm spatial resolution was obtained with Kirkpatrick-Baez optics. The time-resolved small angle diffraction experiment was performed with a time resolution ranging from 10 μs to a few ms. The reversible local layer change between the horizontal chevron and the quasi-bookshelf structure was confirmed by the triangular wave form. The transient layer response for the step form electric field was observed. The layer response closely related with an electric field induced antiferroelectric to ferroelectric phase transition

  2. Penetration route of functional molecules in stratum corneum studied by time-resolved small- and wide-angle x-ray diffraction

    International Nuclear Information System (INIS)

    Hatta, Ichiro; Ohta, Noboru; Yagi, Naoto; Nakazawa, Hiromitsu; Obata, Yasuko; Inoue, Katsuaki

    2011-01-01

    We studied effects of functional molecules on corneocytes in stratum corneum using time-resolved small- and wide-angle x-ray diffraction after applying a functional molecule. From these results it was revealed that in the stratum corneum a typical hydrophilic molecule, ethanol, penetrates via the transcellular route and on the other hand a typical hydrophobic molecule, d-limonene, penetrates via the intercellular route.

  3. Time-resolved x-ray diffraction measurement of C{sub 60} under high pressure and temperature using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Horikawa, T [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Suito, K [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Kobayashi, M [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan); Onodera, A [Graduate School of Engineering Science, Osaka University, Toyonaka, Osaka 560-8531 (Japan)

    2002-11-11

    C{sub 60} has been studied by means of time-resolved x-ray diffraction measurements using synchrotron radiation. Diffraction patterns were recorded at intervals of 1-10 min for samples under high pressure (12.5 and 14.3 GPa) and high temperature (up to 800 deg. C) for, at the longest, 3 h. Time, pressure, and temperature dependences of the C{sub 60} structure are presented and the relevance to the hardness of materials derived from C{sub 60} is discussed.

  4. A high resolution position sensitive X-ray MWPC for small angle X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Tappern, G.J.

    1981-02-01

    A small sealed-off delay line readout MWPC X-ray detector has been designed and built for small angle X-ray diffraction applications. Featuring a sensitive area of 100 mm x 25 mm it yields a spatial resolution of 0.13 mm (standard deviation) with a high rate capability and good quantum efficiency for copper K radiation. (author)

  5. 100 years of discovery of X-ray diffraction

    International Nuclear Information System (INIS)

    Zhang Tao

    2012-01-01

    X-ray diffraction was discovered by Max von Laue a hundred years ago. Later, through the work of William H. Bragg and William L. Bragg, an experimental analysis method was developed to solve the structure of molecules at the atomic level. Over the past hundred years, science and technology has been dramatically changed by X-ray diffraction analysis, which has also undergone considerable development. The recent emergence of hard X-ray free electron lasers has provided a new dimension for X-ray diffraction analysis, promising even greater progress in the fields of physics, chemistry and biology. (author)

  6. Invited article: The fast readout low noise camera as a versatile x-ray detector for time resolved dispersive extended x-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry, and catalysis

    International Nuclear Information System (INIS)

    Labiche, Jean-Claude; Mathon, Olivier; Pascarelli, Sakura; Newton, Mark A.; Ferre, Gemma Guilera; Curfs, Caroline; Vaughan, Gavin; Homs, Alejandro; Carreiras, David Fernandez

    2007-01-01

    Originally conceived and developed at the European Synchrotron Radiation Facility (ESRF) as an 'area' detector for rapid x-ray imaging studies, the fast readout low noise (FReLoN) detector of the ESRF [J.-C. Labiche, ESRF Newsletter 25, 41 (1996)] has been demonstrated to be a highly versatile and unique detector. Charge coupled device (CCD) cameras at present available on the public market offer either a high dynamic range or a high readout speed. A compromise between signal dynamic range and readout speed is always sought. The parameters of the commercial cameras can sometimes be tuned, in order to better fulfill the needs of specific experiments, but in general these cameras have a poor duty cycle (i.e., the signal integration time is much smaller than the readout time). In order to address scientific problems such as time resolved experiments at the ESRF, a FReLoN camera has been developed by the Instrument Support Group at ESRF. This camera is a low noise CCD camera that combines high dynamic range, high readout speed, accuracy, and improved duty cycle in a single image. In this paper, we show its application in a quasi-one-dimensional sense to dynamic problems in materials science, catalysis, and chemistry that require data acquisition on a time scale of milliseconds or a few tens of milliseconds. It is demonstrated that in this mode the FReLoN can be applied equally to the investigation of rapid changes in long range order (via diffraction) and local order (via energy dispersive extended x-ray absorption fine structure) and in situations of x-ray hardness and flux beyond the capacity of other detectors

  7. Observation of Structure of Surfaces and Interfaces by Synchrotron X-ray Diffraction: Atomic-Scale Imaging and Time-Resolved Measurements

    Science.gov (United States)

    Wakabayashi, Yusuke; Shirasawa, Tetsuroh; Voegeli, Wolfgang; Takahashi, Toshio

    2018-06-01

    The recent developments in synchrotron optics, X-ray detectors, and data analysis algorithms have enhanced the capability of the surface X-ray diffraction technique. This technique has been used to clarify the atomic arrangement around surfaces in a non-contact and nondestructive manner. An overview of surface X-ray diffraction, from the historical development to recent topics, is presented. In the early stage of this technique, surface reconstructions of simple semiconductors or metals were studied. Currently, the surface or interface structures of complicated functional materials are examined with sub-Å resolution. As examples, the surface structure determination of organic semiconductors and of a one-dimensional structure on silicon are presented. A new frontier is time-resolved interfacial structure analysis. A recent observation of the structure and dynamics of the electric double layer of ionic liquids, and an investigation of the structural evolution in the wettability transition on a TiO2 surface that utilizes a newly designed time-resolved surface diffractometer, are presented.

  8. Characterization of Metalloproteins and Biomaterials by X-ray Absorption Spectroscopy and X-ray Diffraction

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl

    This thesis presents thework on combining complementary X-rays techniques for studying the structures of proteins and other biomaterials, and consists of three different projects: (i) Characterization of protein powders with X-ray powder diffraction (XRPD). (ii) The combination of X-ray...... crystallography and X-ray absorption spectroscopy (XAS) applied to studying different hexameric insulin conformations. (iii) The structures of polymorphs of strontium ranelate and the distribution of strontium in bone tissue. A procedure for fast identification and verification of protein powders using XRPD...... was correction for disordered bulk-solvent, but also correction for background and optimization of unit cell parameters have to be taken into account. A sample holder was designed for collecting powder diffraction data on a standard laboratory X-ray powder diffractometer. The background was reduced by use...

  9. Deactivation of Zeolite Catalyst H-ZSM-5 during Conversion of Methanol to Gasoline: Operando Time- and Space-Resolved X-ray Diffraction.

    Science.gov (United States)

    Rojo-Gama, Daniel; Mentel, Lukasz; Kalantzopoulos, Georgios N; Pappas, Dimitrios K; Dovgaliuk, Iurii; Olsbye, Unni; Lillerud, Karl Petter; Beato, Pablo; Lundegaard, Lars F; Wragg, David S; Svelle, Stian

    2018-03-15

    The deactivation of zeolite catalyst H-ZSM-5 by coking during the conversion of methanol to hydrocarbons was monitored by high-energy space- and time-resolved operando X-ray diffraction (XRD) . Space resolution was achieved by continuous scanning along the axial length of a capillary fixed bed reactor with a time resolution of 10 s per scan. Using real structural parameters obtained from XRD, we can track the development of coke at different points in the reactor and link this to a kinetic model to correlate catalyst deactivation with structural changes occurring in the material. The "burning cigar" model of catalyst bed deactivation is directly observed in real time.

  10. Thin film characterisation by advanced X-ray diffraction techniques

    International Nuclear Information System (INIS)

    Cappuccio, G.; Terranova, M.L.

    1996-09-01

    The Fifth School on X-ray diffraction from polycrystalline materials was devoted to thin film characterization by advanced X-ray diffraction techniques. Twenty contributions are contained in this volume; all twenty are recorded in the INIS Database. X-ray diffraction is known to be a powerful analytical tool for characterizing materials and understanding their structural features. The aim of these articles is to illustrate the fundamental contribution of modern diffraction techniques (grazing incidence, surface analysis, standing waves, etc.) to the characterization of thin and ultra-thin films, which have become important in many advanced technologies

  11. X-ray Microprobe for Fluorescence and Diffraction Analysis

    International Nuclear Information System (INIS)

    Ice, G.E.

    2005-01-01

    X-ray diffraction (see unit 1.1) and x-ray excited fluorescence analysis are powerful techniques for the nondestructive measurement of crystal structure and chemical composition. X-ray fluorescence analysis is inherently nondestructive with orders of magnitude lower power deposited for the same detectable limit as with fluorescence excited by charged particle probes (Sparks, 1980). X-ray diffraction analysis is sensitive to crystal structure with orders-of-magnitude greater sensitivity to crystallographic strain than electron probes (Rebonato, et al. 1989). When a small-area x-ray microbeam is used as the probe, chemical composition (Z>14), crystal structure, crystalline texture, and crystalline strain distributions can be determined. These distributions can be studied both at the surface of the sample and deep within the sample (Fig. 1). Current state-of-the-art can achieve an ∼1 mm-D x-ray microprobe and an ∼0.1 mm-D x-ray microprobe has been demonstrated (Bilderback, et al., 1994). Despite their great chemical and crystallographic sensitivities, x-ray microprobe techniques have until recently been restricted by inefficient x-ray focusing optics and weak x-ray sources; x-ray microbeam analysis was largely superseded by electron techniques in the 50's. However, interest in x-ray microprobe techniques has now been revived (Howells, et al., 1983; Ice and Sparks, 1984; Chevallier, et al., 1997; Riekel 1992; Thompson, el al., 1992; and Making and Using... 1997) by the development of efficient x-ray focusing optics and ultra-high intensity synchrotron x-ray sources (Buras and Tazzari, 1984; Shenoy, et al., 1988). These advances have increased the achievable microbeam flux by more than 11 orders of magnitude (Fig. 2) (Ice, 1997); the flux in a tunable 1 mm-D beam on a 'so called' 3rd-generation synchrotron source such as the APS can exceed the flux in a fixed-energy mm2 beam on a conventional source. These advances make x-ray microfluorescence and x-ray

  12. Historical development of synchrotron x-ray diffraction topography

    International Nuclear Information System (INIS)

    Kawado, Seiji

    2011-01-01

    After a short history of X-ray diffraction topography, from the early stage of laboratory X-ray topography to recent synchrotron-radiation applications, is described, the development of science and technology for the synchrotron X-ray topography and its industrial applications are reviewed in more detail. In addition, the recent trend to synchrotron topography research is clarified on the basis of several data obtained from 256 papers which have been published since 2000. (author)

  13. Diffraction peaks in x-ray spectroscopy: Friend or foe?

    International Nuclear Information System (INIS)

    Tissot, R.G.; Goehner, R.P.

    1992-01-01

    Diffraction peaks can occur as unidentifiable peaks in the energy spectrum of an x-ray spectrometric analysis. Recently, there has been increased interest in oriented polycrystalline films and epitaxial films on single crystal substrates for electronic applications. Since these materials diffract x-rays more efficiently than randomly oriented polycrystalline materials, diffraction peaks are being observed more frequently in x-ray fluorescent spectra. In addition, micro x-ray spectrometric analysis utilizes a small, intense, collimated x-ray beam that can yield well defined diffraction peaks. In some cases these diffraction peaks can occur at the same position as elemental peaks. These diffraction peaks, although a possible problem in qualitative and quantitative elemental analysis, can give very useful information about the crystallographic structure and orientation of the material being analyzed. The observed diffraction peaks are dependent on the geometry of the x-ray spectrometer, the degree of collimation and the distribution of wavelengths (energies) originating from the x-ray tube and striking the sample

  14. A high-temperature furnace and a heating/drawing device designed for time-resolved X-ray diffraction measurements of polymer solids using imaging plates

    International Nuclear Information System (INIS)

    Murakami, Syozo; Tanno, Kiyomitsu; Tsuji, Masaki; Kohjiya, Shinzo

    1995-01-01

    For time-resolved X-ray diffraction measurements using the imaging plate system in the drawing and/or heating process of polymer solids, a high-temperature furnace for heat treatment and a heating/drawing device were newly designed and constructed. Then, to demonstrate their performance, some experimental results obtained in the drawing process of an extruded/blown film of high-density polyethylene at room temperature and in the crystallization process of an oriented amorphous film of poly(ethylene naphthalene-2,6-dicarboxylate) by heating were presented. Other experimental results obtained using them were also briefly cited. (author)

  15. Serial femtosecond X-ray diffraction of enveloped virus microcrystals

    Directory of Open Access Journals (Sweden)

    Robert M. Lawrence

    2015-07-01

    Full Text Available Serial femtosecond crystallography (SFX using X-ray free-electron lasers has produced high-resolution, room temperature, time-resolved protein structures. We report preliminary SFX of Sindbis virus, an enveloped icosahedral RNA virus with ∼700 Å diameter. Microcrystals delivered in viscous agarose medium diffracted to ∼40 Å resolution. Small-angle diffuse X-ray scattering overlaid Bragg peaks and analysis suggests this results from molecular transforms of individual particles. Viral proteins undergo structural changes during entry and infection, which could, in principle, be studied with SFX. This is an important step toward determining room temperature structures from virus microcrystals that may enable time-resolved studies of enveloped viruses.

  16. High-resolution X-ray diffraction studies of multilayers

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Schnopper, H. W.

    1988-01-01

    High-resolution X-ray diffraction studies of the perfection of state-of-the-art multilayers are presented. Data were obtained using a triple-axis perfect-crystal X-ray diffractometer. Measurements reveal large-scale figure errors in the substrate. A high-resolution triple-axis set up is required...

  17. Preparation of specimens for analysis by: X-ray diffraction and X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Banos L, L.

    2004-01-01

    Specimen preparation is one of the most important requirements in the analysis of samples by X-ray Diffraction and X-ray Fluorescence. This statement is especially true for samples containing different types of materials. There are many forms of specimen suitable for X-ray analysis and the type of the sample as received will generally determine the method of pretreatment. It is convenient to refer to the material received for analysis as the sample, and that, which is actually analyzed as the specimen. The powder Diffraction method assumes that the particles in the specimen are ideally random orientation and that there are enough crystallites in the specimen to achieve a representative intensity distribution for these crystallites. X ray Fluorescence is essentially a comparative method of analysis, it is vital that all standards and unknowns be presented to the spectrometer in a reproducible and identical manner. (Author) 3 refs., 6 figs

  18. Nano structured materials studied by coherent X-ray diffraction

    International Nuclear Information System (INIS)

    Gulden, Johannes

    2013-03-01

    Structure determination with X-rays in crystallography is a rapidly evolving field. Crystallographic methods for structure determination are based on the assumptions about the crystallinity of the sample. It is vital to understand the structure of possible defects in the crystal, because they can influence the structure determination. All conventional methods to characterize defects require a modelling through simulated data. No direct methods exist to image the core of defects in crystals. Here a new method is proposed, which will enable to visualize the individual scatterers around and at defects in crystals. The method is based on coherent X-ray scattering. X-rays are perfectly suited since they can penetrate thick samples and buried structures can be investigated Recent developments increased the coherent flux of X-Ray sources such as synchrotrons by orders of magnitude. As a result, the use of the coherent properties of X-rays is emerging as a new aspect of X-ray science. New upcoming and operating X-ray laser sources will accelerate this trend. One new method which has the capacity to recover structural information from the coherently scattered photons is Coherent X-ray Diffraction Imaging (CXDI). The main focus of this thesis is the investigation of the structure and the dynamics of colloidal crystals. Colloidal crystals can be used as a model for atomic crystals in order to understand the growth and defect structure. Despite the large interest in these structures, many details are still unknown.Therefore, it is vital to develop new approaches to measure the core of defects in colloidal crystals. After an introduction into the basics of the field of coherent X-ray scattering, this thesis introduces a novel method, Small Angle Bragg Coherent Diffractive Imaging, (SAB-CDI). This new measurement technique which besides the relevance to colloidal crystals can be applied to a large variety of nano structured materials. To verify the experimental possibilities the

  19. Nano structured materials studied by coherent X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Gulden, Johannes

    2013-03-15

    Structure determination with X-rays in crystallography is a rapidly evolving field. Crystallographic methods for structure determination are based on the assumptions about the crystallinity of the sample. It is vital to understand the structure of possible defects in the crystal, because they can influence the structure determination. All conventional methods to characterize defects require a modelling through simulated data. No direct methods exist to image the core of defects in crystals. Here a new method is proposed, which will enable to visualize the individual scatterers around and at defects in crystals. The method is based on coherent X-ray scattering. X-rays are perfectly suited since they can penetrate thick samples and buried structures can be investigated Recent developments increased the coherent flux of X-Ray sources such as synchrotrons by orders of magnitude. As a result, the use of the coherent properties of X-rays is emerging as a new aspect of X-ray science. New upcoming and operating X-ray laser sources will accelerate this trend. One new method which has the capacity to recover structural information from the coherently scattered photons is Coherent X-ray Diffraction Imaging (CXDI). The main focus of this thesis is the investigation of the structure and the dynamics of colloidal crystals. Colloidal crystals can be used as a model for atomic crystals in order to understand the growth and defect structure. Despite the large interest in these structures, many details are still unknown.Therefore, it is vital to develop new approaches to measure the core of defects in colloidal crystals. After an introduction into the basics of the field of coherent X-ray scattering, this thesis introduces a novel method, Small Angle Bragg Coherent Diffractive Imaging, (SAB-CDI). This new measurement technique which besides the relevance to colloidal crystals can be applied to a large variety of nano structured materials. To verify the experimental possibilities the

  20. Short-time X-ray diffraction with an efficient-optimized, high repetition-rate laser-plasma X-ray-source; Kurzzeit-Roentgenbeugung mit Hilfe einer Effizienz-optimierten, hochrepetierenden Laser-Plasma-Roentgenquelle

    Energy Technology Data Exchange (ETDEWEB)

    Kaehle, Stephan

    2009-04-23

    This thesis deals with the production and application of ultrashort X-ray pulses. In the beginning different possibilities for the production of X-ray pulses with pulse durations of below one picosecond are presented, whereby the main topic lies on the so called laser-plasma X-ray sources with high repetition rate. In this case ultrashort laser pulses are focused on a metal, so that in the focus intensities of above 10{sup 16} W/cm{sup 2} dominate. In the ideal case in such way ultrafast electrons are produced, which are responsible for line radiation. In these experiments titanium K{sub {alpha}} radiation is produced, thes photons possess an energy of 4.51 keV. For the efficient production of line radiation here the Ti:Sa laser is optimized in view of the laser energy and the pulse shape and the influence of the different parameters on the K{sub {alpha}} production systematically studied. The influences of laser intensity, system-conditioned pre-pulses and of phase modulation are checked. It turns out that beside the increasement of the K{sub {alpha}} radiation by a suited laser intensity a reduction of the X-ray background radiation is of deciding importance for the obtaining of clear diffraction images. This background radiation is mainly composed of bremsstrahlung. It can be suppressed by the avoidance of intrinsic pre-pulses and by means of 2nd-order phase modulation. By means of optical excitation and X-ray exploration experiments the production of acoustic waves after ultrashort optical excitation in a 150 nm thick Ge(111) film on Si(111) is studied. These acoustic waves are driven by thermal (in this time scale time-independent) and electronic (time dependent) pressure amounts. As essential results it turns out that the relative amount of the electronic pressure increases with decreasing excitation density. [German] Diese Arbeit befasst sich mit der Erzeugung und Anwendung ultrakurzer Roentgenimpulse. Zu Beginn werden verschiedene Moeglichkeiten zur

  1. A differential scanning calorimetric and X-ray diffraction

    Indian Academy of Sciences (India)

    X-ray diffraction analysis of the two groups demonstrated predominance of austenitic ... Discrete crystallographic structure and absence of multiple phases showed ... Division of Orthodontics, Indian Army, 10 Corps Dental Unit, C/O 56 APO, ...

  2. Thin film characterisation by advanced X-ray diffraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Cappuccio, G; Terranova, M L [eds.; INFN, Laboratori Nazionali di Frascati, Rome (Italy)

    1996-09-01

    This report described the papers presented at the 5. School on X-ray diffraction from polycrystalline materials held at Frascati (Rome) in 2-5 October 1996. A separate abstract was prepared for each of the papers.

  3. Synchrotron x-ray diffraction study of liquid surfaces

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Pershan, P.S.

    1983-01-01

    A spectrometer for X-ray diffraction and refraction studies of horizontal, free surfaces of liquids is described. As an illustration smetic-A layering at the surface of a liquid crystal is presented.......A spectrometer for X-ray diffraction and refraction studies of horizontal, free surfaces of liquids is described. As an illustration smetic-A layering at the surface of a liquid crystal is presented....

  4. Space- and time-resolved X-ray diffraction from pinned and sliding charge-density-waves in NbSe3

    International Nuclear Information System (INIS)

    Requardt, H.; Nad, F.Ya.; Monceau, P.; Lorenzo, J.E.; Smilgies, D.; Gruebel, G.

    1999-01-01

    We have determined the spatial distribution of the local charge-density-wave (CDW) strain in the sliding state of NbSe 3 . The strain is measured by monitoring the spatially-varying shift q(x) of the CDW satellite wave vector between current contacts. Experiments were carried out at T=90 K in the upper CDW state using high spatial resolution (30-50 μm) X-ray diffraction. Applying direct currents about twice the threshold value, we observe a steep exponential decrease of the shift within a few hundred microns from the contact followed by a linear variation of q in the central section of the sample. This latter regime is attributed to transverse pinning of the CDW dislocation loops (DL), while the exponential regime is controlled by the finite DL nucleation rate. Additional to these data in the stationary state of the sliding CDW, we investigated the relaxation of the CDW strain q(t) upon switching off the current (T=75 K). Using time-resolved high-spatial resolution X-ray diffraction, we observe at 800 μm from the electrode a decay law of the stretched exponential type: q(t)=q 0 exp(-(t/τ) u ), with τ=283 ms and μ=0.37. (orig.)

  5. Automation of a Guinier camera for X-ray diffraction

    International Nuclear Information System (INIS)

    Duijn, J.H.

    1988-01-01

    The automation of a Guinier X-ray diffraction camera is discussed. The photographic plate in the conventional setup has been replaced by a curved proportional counter (CPC) which has an electronic readout system. As a result the recording time has been reduced from a few hours to a few minutes. The construction and optimum dimensions of the CPC are discussed and the most essential parts of the readout electronics are highlighted. A linewidth of 200 μm FWHM and an accuracy of 30 μm are achieved. 45 refs.; 53 figs.; 4 tabs

  6. X-ray diffraction measurements in KCl shocked along [100

    International Nuclear Information System (INIS)

    D'Almeida, T.; Gupta, Y.M.

    2000-01-01

    Real time x-ray diffraction measurements were used to examine the polymorphic phase transformation in KCl shocked along the [100] direction. Shock wave continuum data, obtained previously by Hayes, were used to design the experiments and to predict diffraction from KCl shocked to different peak stresses. Here, we present the results obtained below the transition stress: between 1.4 and 2 GPa. Diffraction data obtained were quantitatively related to macroscopic compression. Interplanar spacing measurements revealed isotropic compression of the unit cell in contrast to previously reported results. Above the transition stress, descriptions of the atomic arrangement with respect to shock propagation (not available in the literature) are required for setting up the detection system. Hence, continuum results in combination with various crystallographic considerations were utilized to obtain data above the transition stress

  7. Two-dimensional time-resolved X-ray diffraction study of liquid/solid fraction and solid particle size in Fe-C binary system with an electrostatic levitator furnace

    International Nuclear Information System (INIS)

    Yonemura, M; Okada, J; Ishikawa, T; Nanao, S; Watanabe, Y; Shobu, T; Toyokawa, H

    2013-01-01

    Liquid state provides functions such as matter transport or a reaction field and plays an important role in manufacturing processes such as refining, forging or welding. However, experimental procedures are significantly difficult for an observation of solidification process of iron and iron-based alloys in order to identify rapid transformations subjected to fast temperature evolution. Therefore, in order to study the solidification in iron and iron-based alloys, we considered a combination of high energy X-ray diffraction measurements and an electrostatic levitation method (ESL). In order to analyze the liquid/solid fraction, the solidification of melted spherical specimens was measured at a time resolution of 0.1 seconds during rapid cooling using the two-dimensional time-resolved X-ray diffraction. Furthermore, the observation of particle sizes and phase identification was performed on a trial basis using X-ray small angle scattering with X-ray diffraction.

  8. X-ray diffraction of multilayers and superlattices

    International Nuclear Information System (INIS)

    Bartels, W.J.; Hornstra, J.; Lobeek, D.J.W.

    1986-01-01

    Recursion formulae for calculating the reflected amplitude ratio of multilayers and superlattices have been derived from the Takagi-Taupin differential equations, which describe the dynamical diffraction of X-rays in deformed crystals. Calculated rocking curves of complicated layered structures, such as non-ideal superlattices on perfect crystals, are shown to be in good agreement with observed diffraction profiles. The kinematical theory can save computing time only in the case of an ideal superlattice, for which a geometric series can be used, but the reflections must be below 10% so that multiple reflections can be neglected. For a perfect crystal of arbitrary thickness the absorption at the center of the dynamical reflection is found to be proportional to the square root of the reflectivity. Sputter-deposited periodic multilayers of tungsten and carbon can be considered as an artificial crystal, for which dynamical X-ray diffraction calculations give results very similar to those of a macroscopic optical description in terms of the complex index of refraction and Fresnel reflection coefficients. (orig.)

  9. Modern trends in x-ray powder diffraction

    International Nuclear Information System (INIS)

    Goebel, H.E.; Snyder, R.L.

    1985-01-01

    The revival of interest in X-ray powder diffraction, being quoted as a metamorphosis from the 'ugly duckling' to a 'beautiful swan', can be attributed to a number of modern developments in instrumentation and evaluation software. They result in faster data collection, improved accuracy and resolution, and better detectability of minor phases. The ease of data evaluation on small computers coupled direct to the instrument allows convenient execution of previously tedious and time-consuming off-line tasks like qualitative and quantitative analysis, characterization of microcrystalline properties, indexing, and lattice-constant refinements, as well as structure refinements or even exploration of new crystal structures. Powder diffraction has also progressed from an isolated analytical laboratory method to an in situ technique for analysing solid-state reactions or for the on-stream control of industrial processes. The paper surveys these developments and their real and potential applications, and tries to emphasize new trends that are regarded as important steps for the further progress of X-ray powder diffraction

  10. X-ray diffraction analysis of InAs nanowires

    International Nuclear Information System (INIS)

    Davydok, Anton

    2013-01-01

    Semiconductor nanowires have attracted great interest as building blocks for future electronic and optoelectronic devices. The variability of the growth process opens the opportunity to control and combine the various properties tailoring for specific application. It was shown that the electrical and optical characteristics of the nanowires are strongly connected with their structure. Despite intensive research in this field, the growth process is still not fully understood. In particular, extensive real structure investigations are required. Most of the reports dedicated on the structural researches are based on the results of scanning electron microscopy (SEM) or transmission electron microscopy (TEM). SEM provides an image of the surface with nanostructures and is mainly used to describe the morphology of the sample, but it does not bring information about the internal structure, phase composition and defect structure. At the same time, the internal structure can be examined by TEM down to atomic scale. TEM image of good quality are very expensive due to the efforts in sample preparation and in localisation of a single object. All these aspects make the statistical structural analysis difficult. In the present work, X-ray diffraction analysis has been applied for structural investigation of InAs nanowires grown by different techniques. Using various X-ray diffraction geometries, the nanowire systems were investigated in terms of the lattice parameters, phase composition, strains and displacement fields and stacking defects. In particular, realizing grazing incidence diffraction and controlling the penetration depth of X-ray beam, we characterized sample series grown by Au-assisted metal organic phase epitaxy on GaAs [111]B substrate with different growth time. According to the results of SEM and X-ray investigations, a model of the growth process has been proposed. A more detailed analysis was performed on InAs nanowires grown by molecular beam epitaxy (MBE) on

  11. Dehydrogenation kinetics of pure and nickel-doped magnesium hydride investigated by in situ time-resolved powder X-ray diffraction

    DEFF Research Database (Denmark)

    Jensen, T.R.; Andreasen, A.; Vegge, Tejs

    2006-01-01

    The dehydrogenation kinetics of pure and nickel (Ni)-doped (2w/w%) magnesium hydride (MgH2) have been investigated by in situ time-resolved powder X-ray diffraction (PXD). Deactivated samples, i.e. air exposed, are investigated in order to focus on the effect of magnesium oxide (MgO) surface layers......, which might be unavoidable for magnesium (Mg)-based storage media for mobile applications. A curved position-sensitive detector covering 120 degrees in 20 and a rotating anode X-ray source provide a time resolution of 45 s and up to 90 powder pattems collected during an experiment under isothermal...... by the Johnson-Mehi-Avrami formalism in order to derive rate constants at different temperatures. The apparent activation energies for dehydrogenation of pure and Ni-doped magnesium hydride were E-A approximate to 300 and 250 kJ/mol, respectively. Differential scanning calorimetry gave, E-A = 270 k...

  12. X-ray photoelectron spectroscopy, high-resolution X-ray diffraction ...

    Indian Academy of Sciences (India)

    the crystalline quality through full-width at half-maximum values. .... angular divergence of ∆α = 12 arc sec. X-rays generated from the monochromator were diffracted from (0 0 6) LiNbO3 atomic planes with the (+, −, −, +, +) geometry. [8].

  13. Spectroscopic imaging, diffraction, and holography with x-ray photoemission

    International Nuclear Information System (INIS)

    1992-02-01

    X-ray probes are capable of determining the spatial structure of an atom in a specific chemical state, over length scales from about a micron all the way down to atomic resolution. Examples of these probes include photoemission microscopy, energy-dependent photoemission diffraction, photoelectron holography, and X-ray absorption microspectroscopy. Although the method of image formation, chemical-state sensitivity, and length scales can be very different, these X-ray techniques share a common goal of combining a capability for structure determination with chemical-state specificity. This workshop will address recent advances in holographic, diffraction, and direct imaging techniques using X-ray photoemission on both theoretical and experimental fronts. A particular emphasis will be on novel structure determinations with atomic resolution using photoelectrons

  14. Spectroscopic imaging, diffraction, and holography with x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    X-ray probes are capable of determining the spatial structure of an atom in a specific chemical state, over length scales from about a micron all the way down to atomic resolution. Examples of these probes include photoemission microscopy, energy-dependent photoemission diffraction, photoelectron holography, and X-ray absorption microspectroscopy. Although the method of image formation, chemical-state sensitivity, and length scales can be very different, these X-ray techniques share a common goal of combining a capability for structure determination with chemical-state specificity. This workshop will address recent advances in holographic, diffraction, and direct imaging techniques using X-ray photoemission on both theoretical and experimental fronts. A particular emphasis will be on novel structure determinations with atomic resolution using photoelectrons.

  15. Crystallized solids characterization by X-ray diffraction

    International Nuclear Information System (INIS)

    Broll, N.

    1996-01-01

    This work deals with the crystallized solids characterization by X-ray diffraction. The powders diffraction principle is described. Then are given the different powders diffraction experimental methods. An X-ray diffraction device is essentially constituted of three parts: the X-rays source, the sample and the detector. The source is usually constituted by an X-rays tube whereas the sample can be fixed on a photographic chamber or put on a goniometer. The different photographic chambers which can be used (Debye-Scherrer, Seeman-Bohlin and Guinier) are described. The powders diffractometer the most used is a Bragg-Brentano focusing diffractometer because it allows to obtain very sharp spectral lines and an important diffracted intensity. The detectors which are the mainly used are the scintillation counters. The most important use in powders diffractometry is the identification of the different phases of a sample. The phases identification consists to compare the unknown sample spectrum at those of standard materials indexed until now. Two methods exist at present. They are explained and their limits in the phases search are given. Another use of the X-ray diffraction is the quantitative analysis. It consists to determine the concentrations of each crystal phases of a sample. The principles of these quantitative methods are given. The lattice parameters of a polycrystal material can be determined from its X-ray pattern too with a very high precision. The way to index powders patterns is given. The residual stresses of materials can also be estimated. The principle of this measured method is explained. It is at last possible to study from an X-ray pattern, the material grain orientations during the different steps of preparation and working. (O.M.). 13 refs., 19 figs., 1 tab

  16. X-ray diffraction topography. Stages and tendencies of development

    International Nuclear Information System (INIS)

    Shul'pina, I.L.

    2000-01-01

    The physical foundation of X-ray diffraction topography, its methods, the achievements in image theory, the stages of evolution were described in this review. It was found that modern topography is well along in development associated with the use of third-generation synchrotron radiation and with its adaptation to advance materials and problems of materials science. Some proposals about prospects for X-ray topography progress in the future have been made [ru

  17. X-ray diffraction microtomography using synchrotron radiation

    CERN Document Server

    Barroso, R C; Jesus, E F O; Oliveira, L F

    2001-01-01

    The X-ray diffraction computed tomography technique is based on the interference phenomena of the coherent scatter. For low-momentum transfer, it is most probable that the scattering interaction will be coherent. A selective discrimination of a given element in a scanned specimen can be realized by fixing the Bragg angle which produces an interference peak and then, to carry out the computed tomography in the standard mode. The image reconstructed exalts the presence of this element with respect to other ones in a sample. This work reports the feasibility of a non-destructive synchrotron radiation X-ray diffraction imaging technique. This research was performed at the X-ray Diffraction beam line of the National Synchrotron Light Laboratory (LNLS) in Brazil. The coherent scattering properties of different tissue and bone substitute materials were evaluated. Furthermore, diffraction patterns of some polycrystalline solids were studied due to industrial and environmental human exposure to these metals. The obtai...

  18. Three-dimensional x-ray diffraction detection and visualization

    International Nuclear Information System (INIS)

    Allahkarami, Masoud; Hanan, Jay C

    2014-01-01

    A new method of sensing and analyzing three-dimensional (3D) x-ray diffraction (XRD) cones was introduced. Using a two-dimensional area detector, a sequence of frames was collected while moving the detector away from the sample with small equally spaced steps and keeping all other parameters constant. A 3D dataset was created from the subsequent frames. The 3D x-ray diffraction (XRD 3 ) pattern contains far more information than a one-dimensional profile collected with the conventional diffractometer and 2D x-ray diffraction (XRD 2 ). The present work discusses some fundamentals about XRD 3 , such as the data collection method, 3D visualization, diffraction data interpretation and potential applications of XRD 3 . (paper)

  19. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  20. High resolution X-ray diffraction studies on unirradiated

    Indian Academy of Sciences (India)

    High-resolution X-ray diffraction technique, employing a three-crystal monochromator–collimator combination is used to study the irradiation induced defects in flux grown Sr-hexaferrite crystals irradiated with 50 MeV Li3+ ion beams at room temperature with a fluence value of 1 × 1014 ions/cm2. The diffraction curves of the ...

  1. Surface and interface strains studied by x-ray diffraction

    International Nuclear Information System (INIS)

    Akimoto, Koichi; Emoto, Takashi; Ichimiya, Ayahiko

    1998-01-01

    The authors have developed a technique of X-ray diffraction in order to measure strain fields near semiconductor surface and interface. The diffraction geometry is using the extremely asymmetric Bragg-case bulk reflection of a small incident angle to the surface and a large angle exiting from the surface. The incident angle of the X-rays is set near critical angle of total reflection by tuning X-ray energy of synchrotron radiation at the Photon Factory, Japan. For thermally grown-silicon oxide/Si(100) interface, the X-ray intensity of the silicon substrate 311 reflection has been measured. From comparison of the full width at half maxima (FWHM) of X-ray rocking curves of various thickness of silicon oxides, it has been revealed that silicon substrate lattice is highly strained in the thin (less than about 5 nm) silicon oxide/silicon system. In order to know the original silicon surface strain, the authors have also performed the same kind of measurements in the ultra-high vacuum chamber. A clean Si(111) 7x7 surface gives sharper X-ray diffraction peak than that of the native oxide/Si(111) system. From these measurements, it is concluded that the thin silicon oxide film itself gives strong strain fields to the silicon substrates, which may be the reason of the existence of the structural transition layer at the silicon oxide/Si interface

  2. In Situ X-ray Diffraction Studies of (De)lithiation Mechanism in Silicon Nanowire Anodes

    KAUST Repository

    Misra, Sumohan; Liu, Nian; Nelson, Johanna; Hong, Seung Sae; Cui, Yi; Toney, Michael F.

    2012-01-01

    -Si product has been observed. In this work, we use an X-ray transparent battery cell to perform in situ synchrotron X-ray diffraction on SiNWs in real time during electrochemical cycling. At deep lithiation voltages the known metastable Li 15Si 4 phase forms

  3. Coherent X-ray diffraction studies of mesoscopic materials

    International Nuclear Information System (INIS)

    Shabalin, Anatoly

    2015-12-01

    This thesis is devoted to three separate projects, which can be considered as independent. First, the dynamical scattering effects in the Coherent X-ray Diffractive Imaging (CXDI) method are discussed. Based on the simulation results, a straightforward method for correction for the refraction and absorption artifacts in the Bragg CXDI reconstruction is suggested. The second part summarizes the results of an Coherent X-ray Diffractive Imaging experiment with a single colloidal crystal grain. A remarkable result is that positions of individual particles in the crystal lattice have been resolved in three dimensions. The third project is devoted to X-ray diffraction experimental studies of structural evolution of colloidal crystalline films upon incremental heating. Based on the results of the analysis a model of structural evolution of a colloidal crystal upon heating on nanoscopic and mesoscopic length scales is suggested.

  4. X-ray powder diffraction data on miscellaneous lanthanide compounds

    International Nuclear Information System (INIS)

    Ferguson, I.F.; Hughes, T.E.

    1978-08-01

    Recent work on neutron absorbing materials has produced various new X-ray diffraction powder patterns of compounds of the lanthanides. Various inconsistencies in previously published data have been noted, and accurate measurements have been made of the lattice parameters of the rare earth oxides Sm 2 0 3 , Eu 2 0 3 , Gd 2 0 3 which have the monoclinic rare earth type B- structure, as well as Eu0. These data are recorded for reference. The optimum conditions for obtaining X-ray powder diffraction data from europium compounds are also noted. (author)

  5. [Diffraction gratings used in x-ray spectroscopy]: Final report

    International Nuclear Information System (INIS)

    Smith, H.I.

    1988-01-01

    This subcontract was initiated in order to facilitate the development at MIT of technologies for fabricating the very fine diffraction grating required in x-ray spectroscopy at Lawrence Livermore Laboratory (LLL). These gratings are generally gold transmission gratings with spatial periods of 200 nm or less. The major focus of our efforts was to develop a means of fabricating gratings of 100 nm period. We explored two approaches: e-beam fabrication of x-ray lithography masks, and achromatic holographic lithography. This work was pursued by Erik Anderson as a major component of his Ph.D. thesis. Erik was successful in both the e-beam and holographic approaches. However, the e-beam method proved to be highly impractical: exposure times of about 115 days would be required to cover an area of 1 cm 2 . The achromatic holography, on the other hand, should be capable of exposing areas well in excess of 1 cm 2 in times under 1 hour. Moreover, 100 nm-period gratings produced by achromatic holography are coherent over their entire area whereas gratings produced by e-beam lithography are coherent only over areas /approximately/100 μm. The remainder of this report consists of portions excerpted from Erik Anderson's thesis. These contain all the details of our work on 100 nm period gratings. 26 refs., 17 figs

  6. Characterization for solidification and phase transformations of pure-titanium steel weld metal with time-resolved X-ray diffraction system

    International Nuclear Information System (INIS)

    Terasaki, Hidenori; Komizo, Yu-ichi; Nishino, Fumihiro; Ikeda, Masahiko

    2007-01-01

    Understanding and controlling solidification and phase transformation process of weld metal is essential for forming the microstructure with superior mechanical property. Recent evolution of analysis technique makes for solidification and phase transformation process to be in-situ analyzed, in direct and reciprocal lattice space. In the present work, unidirectional-solidification and phase transformation in the weld metal of commercial pure-titanium in Gas Tungsten Arc welding was in-situ observed by using Time-Resolved X-Ray Diffraction system with two-dimensional pixel detector. An undulator beam was used as a probe. Larger diffraction area could be detected in the time-resolution of 0.05 seconds, in unidirectional solidification and subsequent phase transformation process of pure-titanium weld metal. Furthermore, the microstructure formation during β-α phase transformation was in situ observed with High temperature Laser Scanning Confocal Microscopy. The crystal configurations in unidirectional solidification of weld metal and rapid change of phase ratio in reconstructive phase transformation were clearly analyzed. (author)

  7. Effects of quartz particle size and water-to-solid ratio on hydrothermal synthesis of tobermorite studied by in-situ time-resolved X-ray diffraction

    International Nuclear Information System (INIS)

    Kikuma, J.; Tsunashima, M.; Ishikawa, T.; Matsuno, S.; Ogawa, A.; Matsui, K.; Sato, M.

    2011-01-01

    Hydrothermal synthesis process of tobermorite (5CaO.6SiO 2 .5H 2 O) has been investigated by in-situ X-ray diffraction using high-energy X-rays from a synchrotron radiation source in combination with a purpose-build autoclave cell. Dissolution rates of quartz were largely affected by its particle size distribution in the starting mixtures. However, the composition (Ca/Si) of non-crystalline C-S-H at the start of tobermorite formation was identical regardless of the quartz dissolution rate. An effect of water-to-solid ratio (w/s) was investigated for samples using fine particle quartz. Tobermorite did not occur with w/s of 1.7 but occurred with w/s higher than 3.0. Surprisingly, however, the dissolution curves of quartz were nearly identical for all samples with w/s from 1.7 to 9, indicating that the dissolution rate is predominated by surface area. Possible reaction mechanism for tobermorite formation will be discussed in terms of Ca and/or silicate ion concentration in the liquid phase and distribution of Ca/Si in non-crystalline C-S-H. - Graphical abstract: Time-resolved XRD data set was obtained at up to 190 deg. C under a saturated steam pressure. Tobermorite (5CaO.6SiO 2 .5H 2 O) formation reaction was investigated in detail for several different starting materials. Highlights: → Hydrothermal formation of tobermorite was monitored by in-situ XRD. → Ca/Si of C-S-H at the start time of tobermorite formation was determined. → The Ca/Si value was identical regardless of the quartz particle size in the starting mixture.

  8. An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes

    Science.gov (United States)

    Calta, Nicholas P.; Wang, Jenny; Kiss, Andrew M.; Martin, Aiden A.; Depond, Philip J.; Guss, Gabriel M.; Thampy, Vivek; Fong, Anthony Y.; Weker, Johanna Nelson; Stone, Kevin H.; Tassone, Christopher J.; Kramer, Matthew J.; Toney, Michael F.; Van Buuren, Anthony; Matthews, Manyalibo J.

    2018-05-01

    In situ X-ray-based measurements of the laser powder bed fusion (LPBF) additive manufacturing process produce unique data for model validation and improved process understanding. Synchrotron X-ray imaging and diffraction provide high resolution, bulk sensitive information with sufficient sampling rates to probe melt pool dynamics as well as phase and microstructure evolution. Here, we describe a laboratory-scale LPBF test bed designed to accommodate diffraction and imaging experiments at a synchrotron X-ray source during LPBF operation. We also present experimental results using Ti-6Al-4V, a widely used aerospace alloy, as a model system. Both imaging and diffraction experiments were carried out at the Stanford Synchrotron Radiation Lightsource. Melt pool dynamics were imaged at frame rates up to 4 kHz with a ˜1.1 μm effective pixel size and revealed the formation of keyhole pores along the melt track due to vapor recoil forces. Diffraction experiments at sampling rates of 1 kHz captured phase evolution and lattice contraction during the rapid cooling present in LPBF within a ˜50 × 100 μm area. We also discuss the utility of these measurements for model validation and process improvement.

  9. Dynamic behaviour of the local layer structure of antiferroelectric liquid crystals under a high electric field measured by time-resolved synchrotron x-ray microbeam diffraction

    International Nuclear Information System (INIS)

    Takahashi, Yumiko; Iida, Atsuo; Takanishi, Yoichi; Ogasawara, Toyokazu; Ishikawa, Ken; Takezoe, Hideo

    2001-01-01

    The local layer structure response to a triangular electric field in an antiferroelectric liquid crystal cell has been measured using synchrotron X-ray diffraction with 3 ms time resolution and a few μm spatial resolution. The initially coexisting vertical and horizontal chevron structures are irreversibly transformed to the layer structure with a rearranged molecular orientation at the surface (so-called vertical bookshelf structure). After the irreversible transformation, the rearranged layer structure shows a reversible transition between the horizontal chevron (high field, ferroelectric state) and the combination of the modified vertical and horizontal chevron (low field, antiferroelectric state) associated with the field-induced antiferroelectric-ferroelectric transition. The reversible layer structure has a smaller horizontal chevron angle (a few degrees) than that in the initial state (about 17deg). The detailed microbeam diffraction revealed that the layer structure at a low electric field consists of a broad vertical chevron with a small chevron angle and a bent bookshelf in combination with a horizontal chevron, depending on the analyzing position. The stripe texture is related to the modified horizontal chevron structure. (author)

  10. Dynamic behaviour of the local layer structure of antiferroelectric liquid crystals under a high electric field measured by time-resolved synchrotron x-ray microbeam diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Yumiko [Graduate University for Advanced Studies, Tsukuba, Ibaraki (Japan); Iida, Atsuo [Institute of Materials Structure Science, High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan); Takanishi, Yoichi; Ogasawara, Toyokazu; Ishikawa, Ken; Takezoe, Hideo [Department of Organic and Polymeric Materials, Tokyo Institute of Technology, Tokyo (Japan)

    2001-05-01

    The local layer structure response to a triangular electric field in an antiferroelectric liquid crystal cell has been measured using synchrotron X-ray diffraction with 3 ms time resolution and a few {mu}m spatial resolution. The initially coexisting vertical and horizontal chevron structures are irreversibly transformed to the layer structure with a rearranged molecular orientation at the surface (so-called vertical bookshelf structure). After the irreversible transformation, the rearranged layer structure shows a reversible transition between the horizontal chevron (high field, ferroelectric state) and the combination of the modified vertical and horizontal chevron (low field, antiferroelectric state) associated with the field-induced antiferroelectric-ferroelectric transition. The reversible layer structure has a smaller horizontal chevron angle (a few degrees) than that in the initial state (about 17deg). The detailed microbeam diffraction revealed that the layer structure at a low electric field consists of a broad vertical chevron with a small chevron angle and a bent bookshelf in combination with a horizontal chevron, depending on the analyzing position. The stripe texture is related to the modified horizontal chevron structure. (author)

  11. Direct methods for surface X-ray diffraction

    International Nuclear Information System (INIS)

    Saldin, D. K.; Harder, R.; Shneerson, V. L.; Vogler, H.; Moritz, W.

    2000-01-01

    We develop of a direct method for surface X-ray diffraction that exploits the holographic feature of a known reference wave from the substrate. A Bayesian analysis of the optimal inference to be made from an incomplete data set suggests a maximum entropy algorithm that balances agreement with the data and other statistical considerations

  12. X-Ray diffraction Investigation of Electrochemically Deposited Copper

    DEFF Research Database (Denmark)

    Pantleon, Karen; Jensen, Jens Dahl; Somers, Marcel A.J.

    2004-01-01

    by the determination of X-ray diffraction (XRD) pole figures and the calculation of the orientation distribution functions. XRD results are discussed in relation to the morphologies of the electrodeposits as investigated with light optical microscopy and correlated with the process parameters during electrodeposition....

  13. The three dimensional X-ray diffraction technique

    DEFF Research Database (Denmark)

    Juul Jensen, Dorte; Poulsen, Henning Friis

    2012-01-01

    This introductory tutorial describes the so called 3 dimensional X-ray diffraction (3DXRD) technique, which allows bulk non-destructive structural characterizations of crystalline materials. The motivations and history behind the development of this technique are described and its potentials...

  14. Fusion bonding of Si wafers investigated by x ray diffraction

    DEFF Research Database (Denmark)

    Weichel, Steen; Grey, Francois; Rasmussen, Kurt

    2000-01-01

    The interface structure of bonded Si(001) wafers with twist angle 6.5 degrees is studied as a function of annealing temperature. An ordered structure is observed in x-ray diffraction by monitoring a satellite reflection due to the periodic modulation near the interface, which results from...

  15. Quantitative determination of phases by X-ray diffraction

    International Nuclear Information System (INIS)

    Azevedo, A.L.T.

    1979-01-01

    The internal standard method for the quantitative determination of phases by X-ray diffraction is presented. The method is applicable to multi-phase materials which may be treated as powder. A discussion on sample preparation and some examples follow. (Author) [pt

  16. Residual cold-work determination by X-ray diffraction

    International Nuclear Information System (INIS)

    Pireau, A.; Vanderborck, Y.

    1990-01-01

    The determination of the cold-work level of materials for fast breeder reactors can be made by different techniques. The report compares different methods for an application on austenitic stainless steels and demonstrates that the X-ray diffraction procedure is a reliable technique. A round robin test has been performed between three laboratories; the results are presented and discussed

  17. X-ray diffraction study of pure plutonium under pressure

    Energy Technology Data Exchange (ETDEWEB)

    Faure, Ph. [CEA, Valduc, F-21120 Is-sur-Tille (France)], E-mail: philippe.faure@cea.fr; Genestier, C. [CEA, Valduc, F-21120 Is-sur-Tille (France)

    2009-03-15

    Atomic volume and bulk modulus represent basic cohesion properties of a material and are therefore linked to many other physical properties. However, large discrepancies are found in the literature regarding values for the bulk modulus of pure plutonium ({alpha}-phase). New X-ray diffraction measurements of plutonium in diamond anvil cell are presented and the isothermal bulk modulus is extracted.

  18. Single photon energy dispersive x-ray diffraction

    International Nuclear Information System (INIS)

    Higginbotham, Andrew; Patel, Shamim; Ciricosta, Orlando; Suggit, Matthew J.; Wark, Justin S.; Hawreliak, James A.; Collins, Gilbert W.; Coppari, Federica; Eggert, Jon H.; Tang, Henry

    2014-01-01

    With the pressure range accessible to laser driven compression experiments on solid material rising rapidly, new challenges in the diagnosis of samples in harsh laser environments are emerging. When driving to TPa pressures (conditions highly relevant to planetary interiors), traditional x-ray diffraction techniques are plagued by increased sources of background and noise, as well as a potential reduction in signal. In this paper we present a new diffraction diagnostic designed to record x-ray diffraction in low signal-to-noise environments. By utilising single photon counting techniques we demonstrate the ability to record diffraction patterns on nanosecond timescales, and subsequently separate, photon-by-photon, signal from background. In doing this, we mitigate many of the issues surrounding the use of high intensity lasers to drive samples to extremes of pressure, allowing for structural information to be obtained in a regime which is currently largely unexplored

  19. Single photon energy dispersive x-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Higginbotham, Andrew; Patel, Shamim; Ciricosta, Orlando; Suggit, Matthew J.; Wark, Justin S. [Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford OX1 3PU (United Kingdom); Hawreliak, James A.; Collins, Gilbert W.; Coppari, Federica; Eggert, Jon H. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Tang, Henry [Department of Earth and Planetary Science, University of California Berkeley, Berkeley, California 94720 (United States)

    2014-03-15

    With the pressure range accessible to laser driven compression experiments on solid material rising rapidly, new challenges in the diagnosis of samples in harsh laser environments are emerging. When driving to TPa pressures (conditions highly relevant to planetary interiors), traditional x-ray diffraction techniques are plagued by increased sources of background and noise, as well as a potential reduction in signal. In this paper we present a new diffraction diagnostic designed to record x-ray diffraction in low signal-to-noise environments. By utilising single photon counting techniques we demonstrate the ability to record diffraction patterns on nanosecond timescales, and subsequently separate, photon-by-photon, signal from background. In doing this, we mitigate many of the issues surrounding the use of high intensity lasers to drive samples to extremes of pressure, allowing for structural information to be obtained in a regime which is currently largely unexplored.

  20. Time-resolved x-ray diffraction from frog skeletal muscle during shortening against an inertial load and a quick release

    International Nuclear Information System (INIS)

    Amemiya, Yoshiyuki; Hashizume, Hiroo; Tameyasu, Tsukasa; Tanaka, Hidehiro; Sugi, Haruo.

    1980-01-01

    A group of Japanese researchers conducted, for the first time in this field, experiments on time-resolved x-ray diffraction of frog (bullfrog, Rana catesbeiana) skeletal muscle in conditions where both the force and the muscle length change with time. During an isotonic twitch under a load of about 0.3 P 0 , the intensity ratio started falling on stimulation and reached a minimum value of 0.5 - 0.6 at the early shortening phase, which was maintained until the beginning of relaxation. Except that the minimum value was not retained until the start of relaxation, the same was observed during a twitch against an inertial load whereby the peak force exerted by the muscle was about 0.4 P 0 . The results may be taken to indicate that the change in the intensity ratio reflects not the time course of shortening but that of force generation. When a quick release (3 - 4% of muscle length) was applied during the rising phase of an isometric twitch, the intensity ratio showed no distinct change. Judging from tentative calculation results, however, the foregoing result is subject to further experiments with a much improved time resolution of the measurements. (Kitajima, A.)

  1. Precise rotational alignment of x-ray transmission diffraction gratings

    International Nuclear Information System (INIS)

    Hill, S.L.

    1988-01-01

    Gold transmission diffraction gratings used for x-ray spectroscopy must sometimes be rotationally aligned to the axis of a diagnostic instrument to within sub-milliradian accuracy. We have fabricated transmission diffraction gratings with high line-densities (grating period of 200 and 300 nm) using uv holographic and x-ray lithography. Since the submicron features of the gratings are not optically visible, precision alignment is time consuming and difficult to verify in situ. We have developed a technique to write an optically visible alignment pattern onto these gratings using a scanning electron microscope (SEM). At high magnification (15000 X) several submicron lines of the grating are observable in the SEM, making it possible to write an alignment pattern parallel to the grating lines in an electron-beam-sensitive coating that overlays the grating. We create an alignment pattern by following a 1-cm-long grating line using the SEM's joystick-controlled translation stage. By following the same grating line we are assured the traveled direction of the SEM electron beam is parallel to the grating to better than 10 μradian. The electron-beam-exposed line-width can be large (5 to 15 μm wide) depending on the SEM magnification, and is therefore optically visible. The exposed pattern is eventually made a permanent feature of the grating by ion beam etching or gold electroplating. The pattern can be used to accurately align the grating to the axis of a diagnostic instrument. More importantly, the alignment of the grating can be quickly verified in situ

  2. Diffraction enhanced X-ray imaging of mammals crystalline lens

    International Nuclear Information System (INIS)

    Antunes, A.; Hoennicke, M.G.; Safatle, A.M.V.; Cusatis, C.; Moraes Barros, P.S.; Morelhao, S.L.

    2005-01-01

    Crystalline lenses are transparent biological materials where the organization of the lens fibers can also be affected by changes at molecular level, and therefore the structure and morphology of the tissue can be correlated to the loss of transparency of the lens. In this work, internal structure of mammal lenses regarding the long-range ordering of the fibers are investigated by diffraction enhanced X-ray imaging (DEI) radiography. Moreover, DEI and absorption X-ray synchrotron radiographs for healthy and cataractous crystalline lenses are compared. Significant differences in healthy and cataractous crystalline lenses are observed

  3. Raman spectroscopy and X-ray diffraction studies on celestite

    International Nuclear Information System (INIS)

    Chen Yenhua; Yu Shucheng; Huang, Eugene; Lee, P.-L.

    2010-01-01

    High-pressure Raman spectroscopy and X-ray diffraction studies of celestite (SrSO 4 ) were carried out in a diamond anvil cell at room temperature. Variation in the Raman vibrational frequency and change of lattice parameters with pressure indicate that a transformation occurs in celestite. This transformation caused an adjustment in the Sr-O polyhedra that affected the stretching-force constant of SO 4 . Moreover, compressibilities along the crystallographic axes decreased in the order a to c to b. From the compression data, the bulk modulus of the celestite was 87 GPa. Both X-ray and Raman data show that the transition in celestite is reversible.

  4. MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

    Science.gov (United States)

    Zimmerman, Wayne; Blake, Dave; Harris, William; Morookian, John Michael; Randall, Dave; Reder, Leonard J.; Sarrazin, Phillipe

    2013-01-01

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  5. Time-resolved X-ray diffraction studies of frog skeletal muscle isometrically twitched by two successive stimuli using synchrotron radiation

    International Nuclear Information System (INIS)

    Tanaka, Hidehiro; Kobayashi, Takakazu; Wakabayashi, Katsuzo

    1986-01-01

    In order to clarify the delay between muscular structural changes and mechanical responses, the intensity changes of the equatorial and myosin layer-line reflections were studied by a time-resolved X-ray diffraction technique using synchrotron radiation. The muscle was stimulated at 12-13 0 C by two successive stimuli at an interval during which the second twitch started while tension was still being exerted by the muscle. At the first twitch, the intensity changes of the 1,0 and 1,1 equatorial reflections reached 65 and 200% of the resting values, and further changes to 55 and 220% were seen at the second twitch, respectively. Although the second twitch decreased not only the time to peak tension but also that to the maximum intensity changes of the equatorial reflections, the delay between the intensity changes and the development of tension at the first twitch were still observed at the second twitch. On the other hand, the intensities of the 42.9 nm off-meridional and the 21.5 nm meridional myosin reflections decreased at the first twitch to the levels found when a muscle was isometrically tetanized, and no further decrease in their intensities was observed at the second twitch. These results indicate that a certain period of time is necessary for myosin heads to contr0116e to tension development after their arrival in the vicinity of the thin filaments during contraction. (Auth.)

  6. Single-pulse x-ray diffraction using polycapillary optics for in situ dynamic diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Maddox, B. R., E-mail: maddox3@llnl.gov; Akin, M. C., E-mail: akin1@llnl.gov; Teruya, A.; Hunt, D.; Hahn, D.; Cradick, J. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Morgan, D. V. [National Security Technologies LLC, Los Alamos, New Mexico 87544 (United States)

    2016-08-15

    Diagnostic use of single-pulse x-ray diffraction (XRD) at pulsed power facilities can be challenging due to factors such as the high flux and brightness requirements for diffraction and the geometric constraints of experimental platforms. By necessity, the x-ray source is usually positioned very close, within a few inches of the sample. On dynamic compression platforms, this puts the x-ray source in the debris field. We coupled x-ray polycapillary optics to a single-shot needle-and-washer x-ray diode source using a laser-based alignment scheme to obtain high-quality x-ray diffraction using a single 16 ns x-ray pulse with the source >1 m from the sample. The system was tested on a Mo sample in reflection geometry using 17 keV x-rays from a Mo anode. We also identified an anode conditioning effect that increased the x-ray intensity by 180%. Quantitative measurements of the x-ray focal spot produced by the polycapillary yielded a total x-ray flux on the sample of 3.3 ± 0.5 × 10{sup 7} molybdenum Kα photons.

  7. Modern X-ray diffraction. X-ray diffractometry for materials scientists, physicists, and chemicists. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Spiess, Lothar; Teichert, Gerd; Schwarzer, Robert; Behnken, Herfried; Genzel, Christoph

    2009-01-01

    This book offers a comprehensive survey over the applications of X-ray diffractions in fields like materials technique, metallurgy, electrotechniques, mechanical engineering, as well as micro- and nanotechniques. The necessary baic knowledges of X-ray diffraction are mediated foundedly and illustratively. Thereby new techniques and evaluation procedures are presented as well as well known methods

  8. Multiple x-ray diffraction simulation and applications

    International Nuclear Information System (INIS)

    Costa, C.A.B.S. da.

    1989-09-01

    A computer program (MULTX) was implemented for simulation X-ray multiple diffraction diagrams in Renninger geometries. The program uses the X-ray multiple diffraction theory for imperfect crystals. The iterative calculation of the intensities is based on the Taylor series general term, and the primary beam power expansion is given as function of the beam x penetration in the crystal surface. This development allows to consider the simultaneous interaction of the beams involved in the multiple diffraction phenomenon. The simulated diagrams are calculated point-to-point and the tests for the Si and GaAs presented good reproduction of the experimental diagrams for different primary reflections. (L.C.J.A.)

  9. Illicit drug detection using energy dispersive x-ray diffraction

    Science.gov (United States)

    Cook, E. J.; Griffiths, J. A.; Koutalonis, M.; Gent, C.; Pani, S.; Horrocks, J. A.; George, L.; Hardwick, S.; Speller, R.

    2009-05-01

    Illicit drugs are imported into countries in myriad ways, including via the postal system and courier services. An automated system is required to detect drugs in parcels for which X-ray diffraction is a suitable technique as it is non-destructive, material specific and uses X-rays of sufficiently high energy to penetrate parcels containing a range of attenuating materials. A database has been constructed containing the measured powder diffraction profiles of several thousand materials likely to be found in parcels. These include drugs, cutting agents, packaging and other innocuous materials. A software model has been developed using these data to predict the diffraction profiles which would be obtained by X-ray diffraction systems with a range of suggested detector (high purity germanium, CZT and scintillation), source and collimation options. The aim of the model was to identify the most promising system geometries, which was done with the aid of multivariate analysis (MVA). The most promising systems were constructed and tested. The diffraction profiles of a range of materials have been measured and used to both validate the model and to identify the presence of drugs in sample packages.

  10. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    Science.gov (United States)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  11. Discovery and development of x-ray diffraction

    Science.gov (United States)

    Jeong, Yeuncheol; Yin, Ming; Datta, Timir

    2013-03-01

    In 1912 Max Laue at University of Munich reasoned x-rays to be short wavelength electromagnetic waves and figured interference would occur when scattered off crystals. Arnold Sommerfeld, W. Wien, Ewald and others, raised objections to Laue's idea, but soon Walter Friedrich succeeded in recording x-ray interference patterns off copper sulfate crystals. But the Laue-Ewald's 3-dimensional formula predicted excess spots. Fewer spots were observed. William Lawrence Bragg then 22 year old studying at Cambridge University heard the Munich results from father William Henry Brag, physics professor at Univ of Leeds. Lawrence figured the spots are 2-d interference of x-ray wavelets reflecting off successive atomic planes and derived a simple eponymous equation, the Bragg equation d*sin(theta) = n*lamda. 1913 onward the Braggs dominated the crystallography. Max Laue was awarded the physics Nobel in 1914 and the Braggs shared the same in 1915. Starting with Rontgen's first ever prize in 1901, the importance of x-ray techniques is evident from the four out of a total 16 physics Nobels between 1901-1917. We will outline the historical back ground and importance of x-ray diffraction giving rise to techniques that even in 2013, remain work horses in laboratories all over the globe.

  12. Real-time synchrotoron radiation X-ray diffraction and abnormal temperature dependence of photoluminescence from erbium silicates on SiO2/Si substrates

    Directory of Open Access Journals (Sweden)

    H. Omi

    2012-03-01

    Full Text Available The erbium silicate formation processes during annealing in Ar gas were monitored by synchrotron radiation grazing incidence X-ray diffraction (GIXD in real time and the optical properties of the silicates were investigated by photoluminescence measurements in spectral and time-resolved domains. The GIXD measurements show that erbium silicates and erbium oxide are formed by interface reactions between silicon oxide and erbium oxides deposited on silicon oxide by reactive sputtering in Ar gas and O2/Ar mixture gas ambiences. The erbium silicates are formed above 1060 °C in Ar gas ambience and above 1010 °C in O2/Ar gas ambience, and erbium silicides are dominantly formed above 1250 °C. The I15/2-I13/2 Er3+ photoluminescence from the erbium oxide and erbium silicate exhibits abnormal temperature dependence, which can be explained by the phonon-assisted resonant absorption of the 532-nm excitation photons into the 2H11/2 levels of Er3+ ions of the erbium compounds.

  13. Time-resolved suprathermal x-rays

    International Nuclear Information System (INIS)

    Lee, P.H.Y.; Rosen, M.D.

    1978-01-01

    Temporally resolved x-ray spectra in the range of 1 to 20 keV have been obtained from gold disk targets irradiated by 1.06 μm laser pulses from the Argus facility. The x-ray streak camera used for the measurement has been calibrated for streak speed and dynamic range by using an air-gap Fabry-Perot etalon, and the instrument response has been calibrated using a multi-range monoenergetic x-ray source. The experimental results indicate that we are able to observe the ''hot'' x-ray temperature evolve in time and that the experimentally observed values can be qualitatively predicted by LASNEX code computations when the inhibited transport model is used

  14. Extinction correction in white X-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Tomiyoshi, S.; Yamada, M.; Watanabe, H.

    1980-01-01

    Extinction effects in white-beam X-ray and neutron diffraction are considered. In white-beam diffraction, a small deviation of the wavelength from the Bragg condition Δlambda is a variable which represents the line profile of the diffraction peaks, so that by using the new parameter Δlambda the theory is converted to one in white-beam diffraction. It is shown that for a convex crystal, primary extinction agrees with the results calculated already for monochromatic diffraction. The same relation is shown to hold in secondary extinction. It is concluded that extinction theory derived for monochromatic diffraction is applicable without any modification in white-beam diffraction. (Auth.)

  15. IL 12: Femtosecond x-ray powder diffraction

    International Nuclear Information System (INIS)

    Woerner, M.; Zamponi, F.; Rothhardt, P.; Ansari, Z.; Dreyer, J.; Freyer, B.; Premont-Schwarz, M.; Elsaesser, T.

    2010-01-01

    A chemical reaction generates new compounds out of one or more initial species. On a molecular level, the spatial arrangement of electrons and nuclei changes. While the structure of the initial and the product molecules can be measured routinely, the transient structures and molecular motions during a reaction have remained unknown in most cases. This knowledge, however, is a key element for the exact understanding of the reaction. The ultimate dream is a 'reaction microscope' which allows for an in situ imaging of the molecules during a reaction. We report on the first femtosecond x-ray powder diffraction experiment in which we directly map the transient electronic charge density in the unit cell of a crystalline solid with 30 pico-meter spatial and 100 femtosecond temporal resolution. X-ray diffraction from polycrystalline powder samples, the Debye Scherrer diffraction technique, is a standard method for determining equilibrium structures. The intensity of the Debye Scherrer rings is determined by the respective x-ray structure factor which represents the Fourier transform of the spatial electron density. In our experiments, the transient intensity and angular positions of up to 20 Debye Scherrer reactions from a polycrystalline powder are measured and unravel for the first time a concerted electron and proton transfer in hydrogen-bonded ionic (NH 4 ) 2 SO 4 crystals. Photoexcitation of ammonium sulfate induces a sub-100 fs electron transfer from the sulfate groups into a highly conned electron channel along the z-axis of the unit cell. The latter geometry is stabilized by transferring protons from the adjacent ammonium groups into the channel. Time-dependent charge density maps derived from the diffraction data display a periodic modulation of the channels charge density by low-frequency lattice motions with a concerted electron and proton motion between the channel and the initial proton binding site. A deeper insight into the underlying microscopic

  16. Diffraction anomalous fine structure using X-ray anomalous dispersion

    International Nuclear Information System (INIS)

    Soejima, Yuji; Kuwajima, Shuichiro

    1998-01-01

    A use of X-ray anomalous dispersion effects for structure investigation has recently been developed by using synchrotron radiation. One of the interesting method is the observation of anomalous fine structure which arise on diffraction intensity in energy region of incident X-ray at and higher than absorption edge. The phenomenon is so called Diffraction Anomalous Fine Structure (DAFS). DAFS originates in the same physical process an that of EXAFS: namely photoelectric effect at the corresponding atom and the interaction of photoelectron waves between the atom and neighboring atoms. In contrast with EXAFS, the method is available for only the crystalline materials, but shows effective advantages of the structure investigations by a use of diffraction: one is the site selectivity and the other is space selectivity. In the present study, demonstrations of a use of X-ray anomalous dispersion effect for the superstructure determination will be given for the case of PbZrO 3 , then recent trial investigations of DAFS in particular on the superlattice reflections will be introduced. In addition, we discuss about Forbidden Reflection near Edge Diffraction (FRED) which is more recently investigated as a new method of the structure analysis. (author)

  17. An autonomous CZT module for X-ray diffraction imaging

    International Nuclear Information System (INIS)

    Montemont, G.; Monnet, O.; Stanchina, S.; Verger, L.; Kosciesza, D.; Schlomka, J.P.

    2013-01-01

    We present the development of a CZT-based detection module dedicated to X-ray diffraction imaging. This kind of application requires a good energy and spatial resolution in order to resolve Bragg peaks. In a first part, we present the detector configuration used and dimensioning constraints. As the input energy range is comprised between 20 and 150 keV, we use 5 mm thick high resistivity CZT crystals. The 660 mm 2 detection area is segmented on both sides into 192 anodes and 12 cathodes. Signals from both sides are read jointly in order to perform multi parametric event corrections (depth of interaction, charge sharing, induction sharing). In order to be integrated easily inside an X-ray imaging system, the system has been conceived to be completely autonomous: it is powered by a single 12 V supply and is interfaced with the external system by Ethernet for communication and RS485 for synchronization. In a second part, we describe the system readout architecture and then the implementation of the data processing. An FPGA circuit embeds a digital processing chain that carries out readout ASIC interfacing and advanced multi parametric data corrections. Gain, offset but also depth of interaction and charge sharing are corrected on the flow. Incoming events from different channels are clustered together by comparing their location and time of occurrence. The FPGA also embeds a processor running an operating system that controls the system, carries out all calibrations, automated tests and acquisitions. Eventually, we show the results obtained and demonstrate the relative influence of depth of interaction and charge sharing. Homogeneity of detector behavior is also discussed and the reproducibility of the performance between modules is presented. The average energy resolution at 25 C is 2.4 % FWHM at 122 keV and 3.8 % FWHM at 60 keV and the average efficiency is 73 %. (authors)

  18. X-ray diffraction study of directionally grown perylene crystallites

    DEFF Research Database (Denmark)

    Breiby, Dag W.; Lemke, H. T.; Hammershøj, P.

    2008-01-01

    Using grazing incidence X-ray diffraction, perylene crystallites grown on thin highly oriented poly(tetrafluoroethylene) (PTFE) films on silicon substrates have been investigated. All the perylene crystallites are found to orient with the ab plane of the monoclinic unit cell parallel to the subst......Using grazing incidence X-ray diffraction, perylene crystallites grown on thin highly oriented poly(tetrafluoroethylene) (PTFE) films on silicon substrates have been investigated. All the perylene crystallites are found to orient with the ab plane of the monoclinic unit cell parallel...... to the substrate. The scattering data is interpreted as a trimodal texture of oriented perylene crystallites, induced by interactions between the perylene molecules and the oriented PTFE substrate. Three families of biaxial orientations are seen, with the axes (h = 1, 2, or 3) parallel to the PTFE alignment......, all having the ab-plane parallel to the substrate. About 92% of the scattered intensity corresponds to a population with highly parallel to (PTFE)....

  19. X-ray diffraction and measurement of residual stresses

    International Nuclear Information System (INIS)

    Maeder, G.; Lebrun, J.L.; Corcaud, L.

    1977-01-01

    X-ray diffraction technique is a non destructive method for measuring the residual stresses in mechanical parts. This method, called sin 2 PSI method is investigated. It is applied to the measurement of elastic constants in different directions of crystals of Zr alloy (Zircaloy 4) and Ti alloy (TA6V). Stresses in TA6V sheets welded by TIG and electron beam processes are also studied [fr

  20. X-ray diffraction from single GaAs nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Biermanns, Andreas

    2012-11-12

    In recent years, developments in X-ray focussing optics have allowed to produce highly intense, coherent X-ray beams with spot sizes in the range of 100 nm and below. Together with the development of new experimental stations, X-ray diffraction techniques can now be applied to study single nanometer-sized objects. In the present work, X-ray diffraction is applied to study different aspects of the epitaxial growth of GaAs nanowires. Besides conventional diffraction methods, which employ X-ray beams with dimensions of several tens of {mu}m, special emphasis lies on the use of nanodiffraction methods which allow to study single nanowires in their as-grown state without further preparation. In particular, coherent X-ray diffraction is applied to measure simultaneously the 3-dimensional shape and lattice parameters of GaAs nanowires grown by metal-organic vapor phase epitaxy. It is observed that due to a high density of zinc-blende rotational twins within the nanowires, their lattice parameter deviates systematically from the bulk zinc-blende phase. In a second step, the initial stage in the growth of GaAs nanowires on Si (1 1 1) surfaces is studied. This nanowires, obtained by Ga-assisted growth in molecular beam epitaxy, grow predominantly in the cubic zinc-blende structure, but contain inclusions of the hexagonal wurtzite phase close to their bottom interface. Using nanodiffraction methods, the position of the different structural units along the growth axis is determined. Because the GaAs lattice is 4% larger than silicon, these nanowires release their lattice mismatch by the inclusion of dislocations at the interface. Whereas NWs with diameters below 50 nm are free of strain, a rough interface structure in nanowires with diameters above 100 nm prevents a complete plastic relaxation, leading to a residual strain at the interface that decays elastically along the growth direction. Finally, measurements on GaAs-core/InAs-shell nanowire heterostructures are presented

  1. X-ray Laue diffraction with allowance for second derivatives of amplitudes in dynamical diffraction equations

    International Nuclear Information System (INIS)

    Balyan, M.K.

    2014-01-01

    Asymmetrical Laue diffraction in a perfect crystal with a plane entrance surface is considered. The second derivatives of amplitudes in the direction, perpendicular to diffraction plane in the dynamical diffraction equations are taken into account. Using the corresponding Green function a general form for the amplitude of diffracted wave in the crystal is derived. The sizes of the source in both directions as well as the source of crystal distance and non-monochromaticity of the radiation incident on the crystal are taken into account. On the basis of obtained expression the coherent properties of the field depending on the sizes of the source and on the width of the spectrum of the incident radiation are analyzed. Taking into account the second derivatives of amplitudes with respect to the direction, perpendicular to the diffraction plane, the time dependent propagation equations for an X-ray pulse in a perfect crystal are given

  2. Time-resolved X-ray diffraction study on superconducting YBa{sub 2}Cu{sub 3}O{sub 7} epitaxially grown on SrTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Luebcke, A.

    2007-07-01

    In this PhD thesis time-resolved X-ray diffraction in optical pump - X-ray probe scheme was applied for the first time to a High-Temperature Superconductor in the superconducting state. The aim was to study the possible lattice response to optical Cooper pair breaking. As sample a thin YBa{sub 2}Cu{sub 3}O{sub 7} film with a superconducting transition temperature of T{sub c}=90 K, epitaxially grown on a SrTiO{sub 3} single crystal was used. (orig.)

  3. Kinetics and mechanism of transitions involving the lamellar, cubic, inverted hexagonal, and fluid isotropic phases of hydrated monoacylglycerides monitored by time-resolved X-ray diffraction

    International Nuclear Information System (INIS)

    Caffrey, M.

    1987-01-01

    A study of the dynamics and mechanism of the various thermotropic phase transitions undergone by the hydrated monoacylglycerides monoolein and monoelaidin, in the temperature range of 20-120 0 C and from 0 to 5 M NaCl, has been undertaken. Measurements were made by using time-resolved X-ray diffraction at the Cornell High-Energy Synchrotron Source. The lamellar chain order/disorder, lamellar/cubic (body centered, space group No.8), cubic (body centered, No.8)/cubic (primitive No.4), cubic (body centered, No.12)/cubic (primitive, No.4), cubic (primitive, No.4)/fluid isotropic, cubic (body centered, No.12)/inverted hexagonal, cubic (primitive, No.4)/inverted hexagonal, and hexagonal/fluid isotropic transitions were examined under active heating and passive cooling by using a jump in temperature to effect phase transformation. All of the transitions with the exception of the cubic (body centered, No.8)/cubic (primitive, No.4) and the cubic (body centered, No.12)/cubic (primitive, No.4) cooling transitions were found (1) to be repeatable, (2) to be reversible, and (3) to have an upper bound on the transit time (time required to complete the transition) of ≤ 3s. In addition to the time-resolved measurements, data were obtained on the stability of the various phases in the temperature range of 20-120 0 C and from 0 to 5 M NaCl. In the case of fully hydrated monoolein, high salt strongly favors the hexagonal over the cubic (body centered, No.8) phase and slightly elevates the hexagonal/fluid isotropic transition temperature. With fully hydrated monoelaidin, the hexagonal phase which is not observed in the absence of salt becomes the dominant phase at high salt concentration

  4. Kinetics and mechanism of the pressure-induced lamellar order/disorder transition in phosphatidylethanolamine: a time-resolved X-ray diffraction study.

    Science.gov (United States)

    Mencke, A P; Caffrey, M

    1991-03-05

    By using synchrotron radiation, a movie was made of the X-ray scattering pattern from a biological liquid crystal undergoing a phase transition induced by a pressure jump. The system studied includes the fully hydrated phospholipid dihexadecylphosphatidylethanolamine in the lamellar gel (L beta') phase at a temperature of 68 degrees C and a pressure of 9.7 MPa (1400 psig). Following the rapid release of pressure to atmospheric the L beta' phase transforms slowly into the lamellar liquid crystal (L alpha) phase. The pressure perturbation is applied with the intention of producing a sudden phase disequilibrium followed by monitoring the system as it relaxes to its new equilibrium condition. Remarkably, the proportion of sample in the L alpha phase grows linearly with time, taking 37 s to totally consume the L beta' phase. The time dependencies of radius, peak intensity, and width of the powder diffraction ring of the low-angle (001) lamellar reflections were obtained from the movie by image processing. The concept of an "effective pressure" is introduced to account for the temperature variations that accompany the phase transition and to establish that the observed large transit time is indeed intrinsic to the sample and not due to heat exchange with the environment. The reverse transformation, L alpha to L beta', induced by a sudden jump from atmospheric pressure to 9.7 MPa, is complete in less than 13 s. These measurements represent a new approach for studying the kinetics of lipid phase transitions and for gaining insights into the mechanism of the lamellar order/disorder transition.

  5. X-ray diffraction at Bragg angles around π/2

    International Nuclear Information System (INIS)

    Mayolo, C.M.G. de.

    1991-01-01

    X-ray diffraction at Bragg angles around π/2 is studied from the theoretical and experimental points of view. The proposed corrections to the dynamical theory in the θ β ≅ π/2 cases, has been reviewed showing the equivalence between two formalisms leading to a corrected expression for the dependence of the angular parameter y with the angle of incidence. An expression for y valid in the conventional and θ β ≅ π/2 cases has been obtained. A general expression for Bragg law and for energy resolution after a Bragg diffraction was also deduced. (author)

  6. JMFA2—a graphically interactive Java program that fits microfibril angle X-ray diffraction data

    Science.gov (United States)

    Steve P. Verrill; David E. Kretschmann; Victoria L. Herian

    2006-01-01

    X-ray diffraction techniques have the potential to decrease the time required to determine microfibril angles dramatically. In this paper, we discuss the latest version of a curve-fitting toll that permits us to reduce the time required to evaluate MFA X-ray diffraction patterns. Further, because this tool reflects the underlying physics more accurately than existing...

  7. X-Ray Powder Diffraction with Guinier - Haegg Focusing Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Allan

    1970-12-15

    The Guinier - Haegg focusing camera is discussed with reference to its use as an instrument for rapid phase analysis. An actual camera and the alignment procedure employed in its setting up are described. The results obtained with the instrument are compared with those obtained with Debye - Scherrer cameras and powder diffractometers. Exposure times of 15 - 30 minutes with compounds of simple structure are roughly one-sixth of those required for Debye - Scherrer patterns. Coupled with the lower background resulting from the use of a monochromatic X-ray beam, the shorter exposure time gives a ten-fold increase in sensitivity for the detection of minor phases as compared with the Debye - Scherrer camera. Attention is paid to the precautions taken to obtain reliable Bragg angles from Guinier - Haegg film measurements, with particular reference to calibration procedures. The evaluation of unit cell parameters from Guinier - Haegg data is discussed together with the application of tests for the presence of angle-dependent systematic errors. It is concluded that with proper calibration procedures and least squares treatment of the data, accuracies of the order of 0.005% are attainable. A compilation of diffraction data for a number of compounds examined in the Active Central Laboratory at Studsvik is presented to exemplify the scope of this type of powder camera.

  8. X-Ray Powder Diffraction with Guinier - Haegg Focusing Cameras

    International Nuclear Information System (INIS)

    Brown, Allan

    1970-12-01

    The Guinier - Haegg focusing camera is discussed with reference to its use as an instrument for rapid phase analysis. An actual camera and the alignment procedure employed in its setting up are described. The results obtained with the instrument are compared with those obtained with Debye - Scherrer cameras and powder diffractometers. Exposure times of 15 - 30 minutes with compounds of simple structure are roughly one-sixth of those required for Debye - Scherrer patterns. Coupled with the lower background resulting from the use of a monochromatic X-ray beam, the shorter exposure time gives a ten-fold increase in sensitivity for the detection of minor phases as compared with the Debye - Scherrer camera. Attention is paid to the precautions taken to obtain reliable Bragg angles from Guinier - Haegg film measurements, with particular reference to calibration procedures. The evaluation of unit cell parameters from Guinier - Haegg data is discussed together with the application of tests for the presence of angle-dependent systematic errors. It is concluded that with proper calibration procedures and least squares treatment of the data, accuracies of the order of 0.005% are attainable. A compilation of diffraction data for a number of compounds examined in the Active Central Laboratory at Studsvik is presented to exemplify the scope of this type of powder camera

  9. Measurements of transient electron density distributions by femtosecond X-ray diffraction

    International Nuclear Information System (INIS)

    Freyer, Benjamin

    2013-01-01

    This thesis concerns measurements of transient charge density maps by femtosecond X-ray diffraction. Different X-ray diffraction methods will be considered, particularly with regard to their application in femtosecond X-ray diffraction. The rotation method is commonly used in stationary X-ray diffraction. In the work in hand an X-ray diffraction experiment is demonstrated, which combines the method with ultrafast X-ray pulses. This experiment is the first implementation which makes use of the rotation method to map transient intensities of a multitude of Bragg reflections. As a prototype material Bismuth is used, which previously was studied frequently by femtosecond X-ray diffraction by measuring Bragg reflections successively. The experimental results of the present work are compared with the literature data. In the second part a powder-diffraction experiment will be presented, which is used to study the dynamics of the electron-density distribution on ultrafast time scales. The experiment investigates a transition metal complex after photoexcitation of the metal to ligand charge transfer state. Besides expected results, i. e. the change of the bond length between the metal and the ligand and the transfer of electronic charge from the metal to the ligand, a strong contribution of the anion to the charge transfer was found. Furthermore, the charge transfer has predominantly a cooperative character. That is, the excitation of a single complex causes an alteration of the charge density of several neighboring units. The results show that more than 30 transition-metal complexes and 60 anions contribute to the charge transfer. This collective response is a consequence of the strong coulomb interactions of the densely packed ions.

  10. Three-Dimensional X-Ray Diffraction Technique for Metals Science

    DEFF Research Database (Denmark)

    Zhang, Yubin; Fan, Guohua

    2017-01-01

    The three-dimensional X-ray diffraction (3DXRD) is a new, advanced technique for materials characterization. This technique utilizes high-energy synchrotron X-rays to characterize the 3D crystallographic structure and strain/stress state of bulk materials. As the measurement is non......-destructive, the microstructural evolution as a function of time can be followed, i.e. it allows 4D (x, y, z characterizations, t). The high brilliance of synchrotron X-rays ensures that diffraction signals from volumes of micrometer scale can be quickly detected and distinguished from the background noise, i.e. its spatial...... implemented in several large synchrotron facilities, e.g. the Advanced Photon Source (APS) in USA and the Spring-8 in Japan. Another family of 3DXRD technique that utilizes white beam synchrotron X-rays has also been developed in parallel in cooperation between Oak Ridge National Laboratory and APS...

  11. Design and fabrication of micro X-ray diffraction system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Soon; Han, Sun Ho; Kim, Jong Goo; Jee, Kwang Yong

    2006-10-15

    It has been observed that microstructure changes occur at the pellet periphery(rim) of the fuel at very high burn-up. Despite its narrow range (below some hundreds microns in depth), this peripheral region(rim) determines the behaviour of nuclear fuel. To determine lattice parameter with XRD at intervals as small as 30-50 {mu} m in radial direction of irradiated fuel samples, a micro X-ray diffraction system was designed and fabricated. This report describes the micro X-ray diffraction system consisted of an X-ray microbeam alignment system and a sample micro translation system, its characterization, and its performance test through the analysis for the micro region of some specimens. This system will be set in a radiation shielded glove box, and then used for analysis of lattice parameter change and the phase change at intervals as small as 30-50 {mu} m in radial direction of the rim of an irradiated fuel sample and a fuel cladding.

  12. Design and fabrication of micro X-ray diffraction system

    International Nuclear Information System (INIS)

    Park, Yang Soon; Han, Sun Ho; Kim, Jong Goo; Jee, Kwang Yong

    2006-10-01

    It has been observed that microstructure changes occur at the pellet periphery(rim) of the fuel at very high burn-up. Despite its narrow range (below some hundreds microns in depth), this peripheral region(rim) determines the behaviour of nuclear fuel. To determine lattice parameter with XRD at intervals as small as 30-50 μ m in radial direction of irradiated fuel samples, a micro X-ray diffraction system was designed and fabricated. This report describes the micro X-ray diffraction system consisted of an X-ray microbeam alignment system and a sample micro translation system, its characterization, and its performance test through the analysis for the micro region of some specimens. This system will be set in a radiation shielded glove box, and then used for analysis of lattice parameter change and the phase change at intervals as small as 30-50 μ m in radial direction of the rim of an irradiated fuel sample and a fuel cladding

  13. Cation Movements during Dehydration and NO2 Desorption in a Ba-Y,FAU zeolite: an in situ Time-resolved X-ray Diffraction Study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xianqin; Hanson, Jonathan C.; Kwak, Ja Hun; Szanyi, Janos; Peden, Charles HF

    2013-02-28

    Synchrotron-based in situ time-resolved X-ray diffraction and Rietveld analysis were used to probe the interactions between BaY, FAU zeolite frameworks and H2O or NO2 molecules. These results provided information about the migration of the Ba2+ cations in the zeolite framework during dehydration and during NO2 adsorption/desorption processes in a water free zeolite. In the hydrated structure water molecules form four double rings of hexagonal ice-like clusters [(H2O)6] in the 12-ring openings of the super-cage. These water rings interacted with the cations and the zeolite framework through four cation/water clusters centered over the four 6-membered rings of the super-cage (site II). Interpenetrating tetrahedral water clusters [(H2O)4] and tetrahedral Ba+2 cation clusters were observed in the sodalite cage. Consistent with the reported FT-IR results, three different ionic NOx species (NO+, NO+-NO2, and NO3-) were observed following NO2 adsorption by the dehydrated Ba-Y,FAU zeolite. The structure of the water and the NOx species were correlated with the interactions between the adsorbates, the cations, and the framework. The population of Ba2+ ions at different cationic positions strongly depended on the amount of bound water or NOx species. Both dehydration and NO2 adsorption/desorption resulted in facile migration of Ba2+ ions among the different cationic positions. Data obtained in this work have provided direct evidence for the Ba2+ cation migration to accommodate the binding of gas molecules. This important feature may play a pivotal role in the strong binding of NO2 to Ba-Y,FAU zeolite, a prerequisite for high catalytic activity in lean NOx reduction catalysis.

  14. Diffraction enhanced kinetic depth X-ray imaging

    Science.gov (United States)

    Dicken, A.

    An increasing number of fields would benefit from a single analytical probe that can characterise bulk objects that vary in morphology and/or material composition. These fields include security screening, medicine and material science. In this study the X-ray region is shown to be an effective probe for the characterisation of materials. The most prominent analytical techniques that utilise X-radiation are reviewed. The study then focuses on methods of amalgamating the three dimensional power of kinetic depth X-ray (KDFX) imaging with the materials discrimination of angular dispersive X-ray diffraction (ADXRD), thus providing KDEX with a much needed material specific counterpart. A knowledge of the sample position is essential for the correct interpretation of diffraction signatures. Two different sensor geometries (i.e. circumferential and linear) that are able to collect end interpret multiple unknown material diffraction patterns and attribute them to their respective loci within an inspection volume are investigated. The circumferential and linear detector geometries are hypothesised, simulated and then tested in an experimental setting with the later demonstrating a greater ability at discerning between mixed diffraction patterns produced by differing materials. Factors known to confound the linear diffraction method such as sample thickness and radiation energy have been explored and quantified with a possible means of mitigation being identified (i.e. via increasing the sample to detector distance). A series of diffraction patterns (following the linear diffraction approach) were obtained from a single phantom object that was simultaneously interrogated via KDEX imaging. Areas containing diffraction signatures matched from a threat library have been highlighted in the KDEX imagery via colour encoding and match index is inferred by intensity. This union is the first example of its kind and is called diffraction enhanced KDEX imagery. Finally an additional

  15. Time-resolved x-ray diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.

    1981-01-01

    Techniques for time-resolved x-ray diagnostics will be reviewed with emphasis on systems utilizing x-ray diodes or scintillators. System design concerns for high-bandwidth (> 1 GHz) diagnostics will be emphasized. The limitations of a coaxial cable system and a technique for equalizing to improve bandwidth of such a system will be reviewed. Characteristics of new multi-GHz amplifiers will be presented. An example of a complete operational system on the Los Alamos Helios laser will be presented which has a bandwidth near 3 GHz over 38 m of coax. The system includes the cable, an amplifier, an oscilloscope, and a digital camera readout

  16. X-ray diffraction imaging of biological cells

    CERN Document Server

    Nakasako, Masayoshi

    2018-01-01

    In this book, the author describes the development of the experimental diffraction setup and structural analysis of non-crystalline particles from material science and biology. Recent advances in X-ray free electron laser (XFEL)-coherent X-ray diffraction imaging (CXDI) experiments allow for the structural analysis of non-crystalline particles to a resolution of 7 nm, and to a resolution of 20 nm for biological materials. Now XFEL-CXDI marks the dawn of a new era in structural analys of non-crystalline particles with dimensions larger than 100 nm, which was quite impossible in the 20th century. To conduct CXDI experiments in both synchrotron and XFEL facilities, the author has developed apparatuses, named KOTOBUKI-1 and TAKASAGO-6 for cryogenic diffraction experiments on frozen-hydrated non-crystalline particles at around 66 K. At the synchrotron facility, cryogenic diffraction experiments dramatically reduce radiation damage of specimen particles and allow tomography CXDI experiments. In addition, in XFEL ex...

  17. Fourier techniques in X-ray timing

    NARCIS (Netherlands)

    van der Klis, M.

    1988-01-01

    Basic principles of Fourier techniques often used in X-ray time series analysis are reviewed. The relation between the discrete Fourier transform and the continuous Fourier transform is discussed to introduce the concepts of windowing and aliasing. The relation is derived between the power spectrum

  18. Note: Application of a pixel-array area detector to simultaneous single crystal x-ray diffraction and x-ray absorption spectroscopy measurements

    International Nuclear Information System (INIS)

    Sun, Cheng-Jun; Brewe, Dale L.; Heald, Steve M.; Zhang, Bangmin; Chen, Jing-Sheng; Chow, G. M.; Venkatesan, T.

    2014-01-01

    X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) are two main x-ray techniques in synchrotron radiation facilities. In this Note, we present an experimental setup capable of performing simultaneous XRD and XAS measurements by the application of a pixel-array area detector. For XRD, the momentum transfer in specular diffraction was measured by scanning the X-ray energy with fixed incoming and outgoing x-ray angles. By selecting a small fixed region of the detector to collect the XRD signal, the rest of the area was available for collecting the x-ray fluorescence for XAS measurements. The simultaneous measurement of XRD and X-ray absorption near edge structure for Pr 0.67 Sr 0.33 MnO 3 film was demonstrated as a proof of principle for future time-resolved pump-probe measurements. A static sample makes it easy to maintain an accurate overlap of the X-ray spot and laser pump beam

  19. Real time 2 dimensional detector for charged particle and soft X-ray images

    International Nuclear Information System (INIS)

    Ishikawa, M.; Ito, M.; Endo, T.; Oba, K.

    1995-01-01

    The conventional instruments used in experiments for the soft X-ray region such as X-ray diffraction analysis are X-ray films or imaging plates. However, these instruments are not suitable for real time observation. In this paper, newly developed imaging devices will be presented, which have the capability to take X-ray images in real time with a high detection efficiency. Also, another capability, to take elementary particle tracking images, is described. (orig.)

  20. Diamond-anvil cell for radial x-ray diffraction

    International Nuclear Information System (INIS)

    Chesnut, G N; Schiferl, D; Streetman, B D; Anderson, W W

    2006-01-01

    We have designed a new diamond-anvil cell capable of radial x-ray diffraction to pressures of a few hundred GPa. The diffraction geometry allows access to multiple angles of Ψ, which is the angle between each reciprocal lattice vector g(hkl) and the compression axis of the cell. At the 'magic angle', Ψ∼54.7 0 , the effects of deviatoric stresses on the interplanar spacings, d(hkl), are significantly reduced. Because the systematic errors, which are different for each d(hkl), are significantly reduced, the crystal structures and the derived equations of state can be determined reliably. At other values of Ψ, the effects of deviatoric stresses on the diffraction pattern could eventually be used to determine elastic constants

  1. X-ray diffraction analysis device with electronic photon counter

    International Nuclear Information System (INIS)

    Fillit, R.Y.; Bruyas, H.; Patay, F.

    1985-01-01

    The means provided to control the movements around the three axes are composed of step-by-step motors related to exits control logic which is connected to the calculation and monitored by a clock. The clock monitors also the calculator so as that the calculator controls, together with the programmable clock and control logic, the coordination of the whole rotation movements, along the three rotation axes, their velocity, their duration and the acquisition of the measured intensities of the diffracted X-ray beam [fr

  2. Accidental exposure with X-ray diffraction equipment

    International Nuclear Information System (INIS)

    Montanez, O.; Blanco, D.

    1991-01-01

    The shutter on one of the windows of an X-ray diffraction apparatus was accidentally left open, exposing the worker to the radiation. The worker was wearing a dosimeter film, which was processed immediately to evaluate the potential risk. It was determined that the exposure rate was 350 Roentgen/minute on the skin surface, with corrections being made for the worker's thin clothing. It was concluded that in spite of the worker receiving a relative high dose, it did not reach the threshold value for producing deterministic effects such as cataracts, erythema, and skin damage

  3. New methods of X-ray diffraction spectrometry. II

    International Nuclear Information System (INIS)

    Soerum, H.; Bremer, J.

    1980-01-01

    The construction principles for a flexible X-ray spectrometer can be equipped either with a single curved crystal or with two curved crystals are described. A few of the theoretical 4+32 possible working modes are selected for a closer investigation and examples of recorded spectra are given. It is shown in the general single-crystal case that for a wavelength close to a cut-off energy the narrow diffraction cone has an elliptic section, as predicted by the theory. The spectrometer is discussed in terms of intensity, resolution and dispersive power. A comparison with other types of spectrometer is made. (Auth.)

  4. Powder X-ray diffraction study af alkali alanates

    DEFF Research Database (Denmark)

    Cao, Thao; Mosegaard Arnbjerg, Lene; Jensen, Torben René

    Powder X-ray diffraction study of alkali alanates Thao Cao, Lene Arnbjerg, Torben R. Jensen. Center for Materials Crystallography (CMC), Center for Energy Materials (CEM), iNANO and Department of Chemistry, Aarhus University, DK-8000, Denmark. Abstract: To meet the energy demand in the future...... for mobile applications, new materials with high gravimetric and volumetric storage capacity of hydrogen have to be developed. Alkali alanates are promising for hydrogen storage materials. Sodium alanate stores hydrogen reversibly at moderate conditions when catalysed with, e.g. titanium, whereas potassium...

  5. Synchrotron X-ray diffraction using triple-axis spectrometry

    International Nuclear Information System (INIS)

    Als-Nielsen, J.

    1980-12-01

    High resolution X-ray diffraction studies of (i) monolayers of the noble gases Kr and Ar physiosorbed on graphite (ii) smectic A fluctuations in the nematic and the smectic A phases of liquid crystals are described. The apparatus used is a triple axis spectrometer situated at the storage ring DORIS at Hasylab, DESY, Hamburg. A monochromatic, well collimated beam is extracted from the synchrotron radiation spectrum by Bragg reflection from perfect Si or Ge crystals. The direction of the beam scattered from the sample is determined by Bragg reflection from a perfect Si or Ge crystal. High intensities even with resolution extending beyond the wavelength of visible light can be obtained. (Auth.)

  6. Real-time observation of rotational twin formation during molecular-beam epitaxial growth of GaAs on Si (111) by x-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Hidetoshi, E-mail: hsuzuki@cc.miyazaki-u.ac.jp [Faculty of Engineering, University of Miyazaki, 1-1 Gakuen-Kibanadai-Nishi, Miyazaki 889-2192 (Japan); Nakata, Yuka; Takahasi, Masamitu [Graduate School of Materials Science, University of Hyogo, 3-2-1 Koto, Kamigori-cho, Hyogo 678-1297 (Japan); Quantum Beam Science Center, Japan Atomic Energy Agency, 1-1-1 Koto, Sayo-cho, Hyogo 679-5148 (Japan); Ikeda, Kazuma [Toyota Technological Institute, 2-12-1 Hisakata, Tempaku, Nagoya 468-8511 (Japan); Ohshita, Yoshio; Morohara, Osamu; Geka, Hirotaka; Moriyasu, Yoshitaka [Advanced Devices and Sensor Systems Development Center, Asahi Kasei Co. Ltd., 2-1 Samejima, Fuji 416-8501 (Japan)

    2016-03-15

    The formation and evolution of rotational twin (TW) domains introduced by a stacking fault during molecular-beam epitaxial growth of GaAs on Si (111) substrates were studied by in situ x-ray diffraction. To modify the volume ratio of TW to total GaAs domains, GaAs was deposited under high and low group V/group III (V/III) flux ratios. For low V/III, there was less nucleation of TW than normal growth (NG) domains, although the NG and TW growth rates were similar. For high V/III, the NG and TW growth rates varied until a few GaAs monolayers were deposited; the mean TW domain size was smaller for all film thicknesses.

  7. Control of synchrotron x-ray diffraction by means of standing acoustic waves

    International Nuclear Information System (INIS)

    Zolotoyabko, E.; Quintana, J.P.

    2004-01-01

    Synchrotron x-ray diffraction measurements in quartz crystals of different thickness excited by standing acoustic waves were carried out at the Advanced Photon Source of Argonne National Laboratory. We demonstrated the ability to significantly modify the quartz rocking curves for 20-25 keV x rays by changing the shear wave parameters in the frequency range between 15 and 105 MHz. Dynamic deformation introduced into the crystal lattice by acoustic waves resulted in a remarkable broadening of the rocking curves. The broadening effect strongly depends on the strength of the ultrasound, which can be easily regulated by changing the acoustic amplitude or frequency near the resonance. The maximum rocking curve broadening reached 17 times, which corresponds to the wavelength band, Δλ/λ=4x10 -3 , when used as a monochromator or analyzer for 20-25 keV x rays. The initial rocking curve shape is restored by sweeping the acoustic frequency within a 50-100 kHz range near the resonance. The tunable broadening effect allows effective manipulation of x-ray intensities in time domain. Time-resolved x-ray diffraction measurements under a 19.6 MHz acoustic wave excitation were performed by synchronizing the acoustic wave and x-ray burst periodicity. We used the fact that twice per period the standing wave produces a zero net deformation across the crystal thickness. By introducing an oscillating delay to the acoustic excitation, we were able to effectively change the phase of the acoustic wave relative to the x-ray burst periodicity. The x-ray diffraction intensity was strongly affected by tuning the timing of the x-ray arrivals to the minimum or maximum acoustic deformation. A deep modulation of x rays was observed in a wide frequency range between 0.1 Hz and 1 MHz, which certifies that acoustically excited quartz crystals can potentially be used as slow and fast x-ray modulators with high duty cycle

  8. Unified Theory for Decoding the Signals from X-Ray Florescence and X-Ray Diffraction of Mixtures.

    Science.gov (United States)

    Chung, Frank H

    2017-05-01

    For research and development or for solving technical problems, we often need to know the chemical composition of an unknown mixture, which is coded and stored in the signals of its X-ray fluorescence (XRF) and X-ray diffraction (XRD). X-ray fluorescence gives chemical elements, whereas XRD gives chemical compounds. The major problem in XRF and XRD analyses is the complex matrix effect. The conventional technique to deal with the matrix effect is to construct empirical calibration lines with standards for each element or compound sought, which is tedious and time-consuming. A unified theory of quantitative XRF analysis is presented here. The idea is to cancel the matrix effect mathematically. It turns out that the decoding equation for quantitative XRF analysis is identical to that for quantitative XRD analysis although the physics of XRD and XRF are fundamentally different. The XRD work has been published and practiced worldwide. The unified theory derives a new intensity-concentration equation of XRF, which is free from the matrix effect and valid for a wide range of concentrations. The linear decoding equation establishes a constant slope for each element sought, hence eliminating the work on calibration lines. The simple linear decoding equation has been verified by 18 experiments.

  9. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers

    International Nuclear Information System (INIS)

    Parrot, I.M.; Urban, V.; Gardner, K.H.; Forsyth, V.T.

    2005-01-01

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar[reg] or Twaron[reg

  10. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers.

    Energy Technology Data Exchange (ETDEWEB)

    Parrot, I. M. [Institut Laue-Langevin (ILL); Urban, Volker S [ORNL; Gardner, K. H. [DuPont Experimental Station; Forsyth, V. T. [Institut Laue Langevin and Keele University

    2005-04-01

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar{reg_sign} or Twaron{reg_sign}.

  11. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers

    Science.gov (United States)

    Parrot, I. M.; Urban, V.; Gardner, K. H.; Forsyth, V. T.

    2005-08-01

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar® or Twaron®.

  12. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers

    Energy Technology Data Exchange (ETDEWEB)

    Parrot, I.M. [Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Institute of Science and Technology in Medicine, Keele University Medical School, Staffordshire ST4 7QB (United Kingdom); Urban, V. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6100 (United States); Gardner, K.H. [Department of Materials Science and Engineering University of Delaware, Newark, DE 19719 (United States); Forsyth, V.T. [Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble Cedex 9 (France) and Institute of Science and Technology in Medicine, Keele University Medical School, Staffordshire ST4 7QB (United Kingdom)]. E-mail: tforsyth@ill.fr

    2005-08-15

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar[reg] or Twaron[reg].

  13. X-ray Diffraction Study of Arsenopyrite at High Pressure

    Energy Technology Data Exchange (ETDEWEB)

    D Fan; M Ma; W Zhou; S Wei; Z Chen; H Xie

    2011-12-31

    The high-pressure X-ray diffraction study of a natural arsenopyrite was investigated up to 28.2 GPa using in situ angle-dispersive X-ray diffraction and a diamond anvil cell at National Synchrotron Light Source, Brookhaven National Laboratory. The 16:3:1 methanol-ethanol-water mixture was used as a pressure-transmitting medium. Pressures were measured using the ruby-fluorescence method. No phase change has been observed up to 28.2 GPa. The isothermal equation of state (EOS) was determined. The values of K{sub 0}, and K'{sub 0} refined with a third-order Birch-Murnaghan EOS are K{sub 0} = 123(9) GPa, and K'{sub 0} = 5.2(8). Furthermore, we confirm that the linear compressibilities ({beta}) along a, b and c directions of arsenopyrite is elastically isotropic ({beta}{sub a} = 6.82 x 10{sup -4}, {beta}{sub b} = 6.17 x 10{sup -4} and {beta}{sub c} = 6.57 x 10{sup -4} GPa{sup -1}).

  14. Characterization of Brazilian asphalt using X-ray diffraction

    International Nuclear Information System (INIS)

    Cardoso, Edson R.; Pinto, Nivia G.V.; Almeida, Ana P.G.; Braz, Delson; Lopes, Ricardo T.; Barroso, Regina C.; Motta, Laura M.G.

    2007-01-01

    Asphalt is a sticky, black and highly viscous liquid or semi-solid that is presented in most crude petroleum and in some natural deposits. The X ray diffraction can give valuable information over the characteristics of a material. Thus, the X-ray diffraction (XRD) method was employed to investigate parameters that characterize and differentiate asphalt groups (Boscan, CAP20, CAP40, CAP50/60, CAP50/70 and CAP85/100). The scattering measurements were carried out in θ-2θ reflection geometry using a powder diffractometer Shimadzu XRD-6000 at the Nuclear Instrumentation Laboratory, Brazil. Scans were typically done from 8 deg to 28 deg every 0.05. The parameters analyzed were: FWHM, peak area, peak center, peak height, left half width and right half width. Thus, in this study, scattering profiles from different asphalt groups were carefully measured in order to establish characteristic signatures of these materials. The results indicate that by using three parameters (peak centroid, peak area and peak intensity) it is possible to characterize and differentiate the asphalt. (author)

  15. Quantitative analysis of minerals by X-ray diffraction

    International Nuclear Information System (INIS)

    Pietroluongo, L.R.V.; Veiga, M.M. da

    1982-01-01

    Considerations about the X-ray diffraction technique for quantitative analyses are made; some experiments carried out at CETEM - Centro de Tecnologia Mineral (Rio de Janeiro, Brazil) with synthetic samples and real samples of diatomites (from northeastern region of Brazil) are described. Quartz quantification has been a problem for analytical chemists and is of great importance to the industries which use this raw material. Comments are made about the main factors influencing the intensity of diffracted X-rays, such as: the crystallinity of the mineral phase; the granulometry, the preferential orientation; sample preparation and pressing, the chemical composition of standards and experimental analytical conditions. Several analytical methods used are described: direct measurement of the height or area of a peak resulting from a particular reflection and comparison with a pre-calibrated curve; method of sequential addition of the mineral of interest in the sample and extrapolation of results for ZERO addition; methods of external and internal standards. (C.L.B.) [pt

  16. X-ray diffraction and imaging with a coherent beam: application to X-ray optical elements and to crystals exhibiting phase inhomogeneities

    International Nuclear Information System (INIS)

    Masiello, F.

    2011-05-01

    The exceptional properties of synchrotron light sources have been exploited in very different disciplines, from archaeology to chemistry, from material science to biology, from medicine to physics. Among these properties it is important to mention the high brilliance, continuum spectrum, high degree of polarization, time structure, small source size and divergence of the beam, the last resulting in a high transversal coherence of the produced radiation. This high transversal coherence of the synchrotron sources has permitted the development of new techniques, e.g. phase contrast imaging, X-ray photon correlation spectroscopy and coherent X-ray diffraction imaging (CXDI). This thesis work will consist essentially of three parts. In the first part it will be presented the work done as a member of the X-ray Optics Group of ESRF in the characterization of high quality diamond crystals foreseen as X-ray optical elements. The characterization has been done using different complementary X-ray techniques, such as high resolution diffraction, topography, grazing incidence diffraction, reflectivity and measurements of the coherence preservation using the Talbot effect. In the second part, I will show the result obtained in the study of the temperature behaviours of the domain in periodically poled ferroelectrics crystals. This type of measurements, based on Bragg-Fresnel diffraction, are possible only thanks to the high degree of coherence of the beam. In the third part, I will present the results obtained in the characterization of diamonds foreseen for applications other than X-ray optical elements. (author)

  17. Quantification of rutile in anatase by X-ray diffraction

    International Nuclear Information System (INIS)

    Chavez R, A.

    2001-01-01

    Nowadays the discovering of new and better materials required in all areas of the industry has been lead to the human being to introduce him to this small and great world. The crystalline materials, have properties markedly directional. When it is necessary to realize a quantitative analysis to these materials the task is not easy. The main objective of this work is the research of a real problem, its solution and perfecting of a technique involving the theoretical and experimental principles which allow the quantification of crystalline phases. The chapter 1 treats about the study of crystalline state during the last century, by means of the X-ray diffraction technique. The chapter 2 studies the nature and production of X-rays, the chapter 3 expounds the principles of the diffraction technique which to carry out when it is satisfied the Bragg law studying the powder diffraction method and its applications. In the chapter 4 it is explained how the intensities of the beams diffracted are determined by the atoms positions inside of the elemental cell of the crystal. The properties of the crystalline samples of anatase and rutile are described in the chapter 5. The results of this last analysis are the information which will be processed by means of the auxiliary software: Diffrac AT, Axum and Peakfit as well as the TAFOR and CUANTI software describing this part with more detail in the chapters 6 and 7 where it is mentioned step by step the function of each software until to reach the quantification of crystalline phases, objective of this work. Finally, in the chapter 8 there are a results analysis and conclusions. The contribution of this work is for those learned institutions of limited resources which can tackle in this way the characterization of materials. (Author)

  18. A new theory for X-ray diffraction.

    Science.gov (United States)

    Fewster, Paul F

    2014-05-01

    This article proposes a new theory of X-ray scattering that has particular relevance to powder diffraction. The underlying concept of this theory is that the scattering from a crystal or crystallite is distributed throughout space: this leads to the effect that enhanced scatter can be observed at the `Bragg position' even if the `Bragg condition' is not satisfied. The scatter from a single crystal or crystallite, in any fixed orientation, has the fascinating property of contributing simultaneously to many `Bragg positions'. It also explains why diffraction peaks are obtained from samples with very few crystallites, which cannot be explained with the conventional theory. The intensity ratios for an Si powder sample are predicted with greater accuracy and the temperature factors are more realistic. Another consequence is that this new theory predicts a reliability in the intensity measurements which agrees much more closely with experimental observations compared to conventional theory that is based on `Bragg-type' scatter. The role of dynamical effects (extinction etc.) is discussed and how they are suppressed with diffuse scattering. An alternative explanation for the Lorentz factor is presented that is more general and based on the capture volume in diffraction space. This theory, when applied to the scattering from powders, will evaluate the full scattering profile, including peak widths and the `background'. The theory should provide an increased understanding of the reliability of powder diffraction measurements, and may also have wider implications for the analysis of powder diffraction data, by increasing the accuracy of intensities predicted from structural models.

  19. Controlled molecules for X-ray diffraction experiments at free-electron lasers

    International Nuclear Information System (INIS)

    Stern, Stephan

    2013-12-01

    X-ray diffractive imaging is at the very heart of materials science and has been utilized for decades to solve unknown molecular structures. Nowadays, it serves as the key method of structural biology to solve molecular structures of large biological molecules comprising several thousand or even millions of atoms. However, X-ray diffraction from isolated molecules is very weak. Therefore, the regular and periodic arrangement of a huge number of identical copies of a certain molecule of interest within a crystal lattice has been a necessary condition in order to exploit Bragg diffraction of X-rays. This results in a huge increase in scattered signal and a strongly improved signal-to-noise ratio compared to diffraction from non-crystalline samples. The major bottleneck of structural biology is that many of biologically interesting molecules refuse to form crystals of sufficient size to be used at synchrotron X-ray lightsources. However, novel X-ray free-electron lasers (XFELs), which became operational very recently, promise to address this issue. X-ray pulses provided by XFELs are many orders of magnitude more intense than X-ray pulses from a synchrotron source and at the same time as short as only several tens of femtoseconds. Combined with wavelengths in the nm-pm range, XFELs are well-suited to study ultrafast atomic and molecular dynamics. Additionally, the ultrashort pulses can be utilized to circumvent the damage threshold which set a limit to the incident intensity in X-ray diffraction experiments before. At XFELs, though eventually destroying the investigated sample, no significant sample deterioration happens on the ultrashort timescale of the XFEL pulse and the measured diffraction pattern is due to an (almost) unharmed sample. In the framework of this thesis, the approach of utilizing the highly intense XFEL pulses for X-ray diffraction of weakly-scattering non-crystalline samples was taken to the limit of small isolated molecules. X-ray diffraction was

  20. Controlled molecules for X-ray diffraction experiments at free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Stern, Stephan

    2013-12-15

    X-ray diffractive imaging is at the very heart of materials science and has been utilized for decades to solve unknown molecular structures. Nowadays, it serves as the key method of structural biology to solve molecular structures of large biological molecules comprising several thousand or even millions of atoms. However, X-ray diffraction from isolated molecules is very weak. Therefore, the regular and periodic arrangement of a huge number of identical copies of a certain molecule of interest within a crystal lattice has been a necessary condition in order to exploit Bragg diffraction of X-rays. This results in a huge increase in scattered signal and a strongly improved signal-to-noise ratio compared to diffraction from non-crystalline samples. The major bottleneck of structural biology is that many of biologically interesting molecules refuse to form crystals of sufficient size to be used at synchrotron X-ray lightsources. However, novel X-ray free-electron lasers (XFELs), which became operational very recently, promise to address this issue. X-ray pulses provided by XFELs are many orders of magnitude more intense than X-ray pulses from a synchrotron source and at the same time as short as only several tens of femtoseconds. Combined with wavelengths in the nm-pm range, XFELs are well-suited to study ultrafast atomic and molecular dynamics. Additionally, the ultrashort pulses can be utilized to circumvent the damage threshold which set a limit to the incident intensity in X-ray diffraction experiments before. At XFELs, though eventually destroying the investigated sample, no significant sample deterioration happens on the ultrashort timescale of the XFEL pulse and the measured diffraction pattern is due to an (almost) unharmed sample. In the framework of this thesis, the approach of utilizing the highly intense XFEL pulses for X-ray diffraction of weakly-scattering non-crystalline samples was taken to the limit of small isolated molecules. X-ray diffraction was

  1. Intensity of diffracted X-rays from biomolecules with radiation damage caused by strong X-ray pulses

    International Nuclear Information System (INIS)

    Kai, Takeshi; Tokuhisa, Atsushi; Moribayashi, Kengo; Fukuda, Yuji; Kono, Hidetoshi; Go, Nobuhiro

    2014-01-01

    In order to realize the coherent X-ray diffractive imaging of single biomolecules, the diffraction intensities, per effective pixel of a single biomolecule with radiation damage, caused by irradiation using a strong coherent X-ray pulse, were examined. A parameter survey was carried out for various experimental conditions, using a developed simulation program that considers the effect of electric field ionization, which was slightly reported on in previous studies. The two simple relationships among the parameters were identified as follows: (1) the diffraction intensity of a biomolecule slightly increases with the incident X-ray energy; and that (2) the diffraction intensity is approximately proportional to the target radius, when the radius is longer than 400 Å, since the upper limit of the incident intensity for damage to the biomolecules marginally changes with respect to the target radius. (author)

  2. Variable-metric diffraction crystals for x-ray optics

    International Nuclear Information System (INIS)

    Smither, R.K.; Fernandez, P.B.

    1992-01-01

    A variable-metric (VM) crystal is one in which the spacing between the crystalline planes changes with position in the crystal. This variation can be either parallel to the crystalline planes or perpendicular to the crystalline planes of interest and can be produced by either introducing a thermal gradient in the crystal or by growing a crystal made of two or more elements and changing the relative percentages of the two elements as the crystal is grown. A series of experiments were performed in the laboratory to demonstrate the principle of the variable-metric crystal and its potential use in synchrotron beam lines. One of the most useful applications of the VM crystal is to increase the number of photons per unit bandwidth in a diffracted beam without losing any of the overall intensity. In a normal synchrotron beam line that uses a two-crystal monochromator, the bandwidth of the diffracted photon beam is determined by the vertical opening angle of the beam which is typically 0.10--0.30 mrad or 20--60 arcsec. When the VM crystal approach is applied, the bandwidth of the beam can be made as narrow as the rocking curve of the diffracting crystal, which is typically 0.005--0.050 mrad or 1--10 arcsec. Thus a very large increase of photons per unit bandwidth (or per unit energy) can be achieved through the use of VM crystals. When the VM principle is used with bent crystals, new kinds of x-ray optical elements can be generated that can focus and defocus x-ray beams much like simple lenses where the focal length of the lens can be changed to match its application. Thus both large magnifications and large demagnifications can be achieved as well as parallel beams with narrow bandwidths

  3. Laser plasma x-ray source for ultrafast time-resolved x-ray absorption spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Miaja-Avila

    2015-03-01

    Full Text Available We describe a laser-driven x-ray plasma source designed for ultrafast x-ray absorption spectroscopy. The source is comprised of a 1 kHz, 20 W, femtosecond pulsed infrared laser and a water target. We present the x-ray spectra as a function of laser energy and pulse duration. Additionally, we investigate the plasma temperature and photon flux as we vary the laser energy. We obtain a 75 μm FWHM x-ray spot size, containing ∼106 photons/s, by focusing the produced x-rays with a polycapillary optic. Since the acquisition of x-ray absorption spectra requires the averaging of measurements from >107 laser pulses, we also present data on the source stability, including single pulse measurements of the x-ray yield and the x-ray spectral shape. In single pulse measurements, the x-ray flux has a measured standard deviation of 8%, where the laser pointing is the main cause of variability. Further, we show that the variability in x-ray spectral shape from single pulses is low, thus justifying the combining of x-rays obtained from different laser pulses into a single spectrum. Finally, we show a static x-ray absorption spectrum of a ferrioxalate solution as detected by a microcalorimeter array. Altogether, our results demonstrate that this water-jet based plasma source is a suitable candidate for laboratory-based time-resolved x-ray absorption spectroscopy experiments.

  4. X-Ray Diffraction and Fluorescence Instrument for Mineralogical Analysis at the Lunar Surface, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop LUNA, a compact and lightweight X-Ray Diffraction (XRD) / X-Ray Fluorescence (XRF) instrument for mineralogical analysis of regolith, rock...

  5. X-Ray Diffraction and Fluorescence Instrument for Mineralogical Analysis at the Lunar Surface, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact and lightweight X-Ray Diffraction (XRD) / X-Ray Fluorescence (XRF) instrument for analysis of mineralogical composition of regolith,...

  6. Residual stress estimation of ceramic thin films by X-ray diffraction and indentation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Atar, Erdem; Sarioglu, Cevat; Demirler, Ugur; Sabri Kayali, E.; Cimenoglu, Huseyin

    2003-05-15

    The residual stresses in ceramic thin films obtained by the indentation method have been found to be three times higher than those of the X-ray diffraction method. This discrepancy can be eliminated by setting the geometrical factor for the Vickers pyramid indenter to 1 in the relevant equation of the indentation method.

  7. Residual stress estimation of ceramic thin films by X-ray diffraction and indentation techniques

    International Nuclear Information System (INIS)

    Atar, Erdem; Sarioglu, Cevat; Demirler, Ugur; Sabri Kayali, E.; Cimenoglu, Huseyin

    2003-01-01

    The residual stresses in ceramic thin films obtained by the indentation method have been found to be three times higher than those of the X-ray diffraction method. This discrepancy can be eliminated by setting the geometrical factor for the Vickers pyramid indenter to 1 in the relevant equation of the indentation method

  8. Simultaneous resonant x-ray diffraction measurement of polarization inversion and lattice strain in polycrystalline ferroelectrics

    DEFF Research Database (Denmark)

    Gorfman, S.; Simons, Hugh; Iamsasri, T.

    2016-01-01

    and strain in ferroelectrics is an ongoing challenge that so far has obscured its fundamental behaviour. By utilizing small intensity differences between Friedel pairs due to resonant scattering, we demonstrate a time-resolved X-ray diffraction technique for directly and simultaneously measuring both lattice...

  9. Acemetacin cocrystal structures by powder X-ray diffraction

    Science.gov (United States)

    Bolla, Geetha

    2017-01-01

    Cocrystals of acemetacin drug (ACM) with nicotinamide (NAM), p-aminobenzoic acid (PABA), valerolactam (VLM) and 2-pyridone (2HP) were prepared by melt crystallization and their X-ray crystal structures determined by high-resolution powder X-ray diffraction. The powerful technique of structure determination from powder data (SDPD) provided details of molecular packing and hydrogen bonding in pharmaceutical cocrystals of acemetacin. ACM–NAM occurs in anhydrate and hydrate forms, whereas the other structures crystallized in a single crystalline form. The carboxylic acid group of ACM forms theacid–amide dimer three-point synthon R 3 2(9)R 2 2(8)R 3 2(9) with three different syn amides (VLM, 2HP and caprolactam). The conformations of the ACM molecule observed in the crystal structures differ mainly in the mutual orientation of chlorobenzene fragment and the neighboring methyl group, being anti (type I) or syn (type II). ACM hydrate, ACM—NAM, ACM–NAM-hydrate and the piperazine salt of ACM exhibit the type I conformation, whereas ACM polymorphs and other cocrystals adopt the ACM type II conformation. Hydrogen-bond interactions in all the crystal structures were quantified by calculating their molecular electrostatic potential (MEP) surfaces. Hirshfeld surface analysis of the cocrystal surfaces shows that about 50% of the contribution is due to a combination of strong and weak O⋯H, N⋯H, Cl⋯H and C⋯H interactions. The physicochemical properties of these cocrystals are under study. PMID:28512568

  10. Acemetacin cocrystal structures by powder X-ray diffraction

    Directory of Open Access Journals (Sweden)

    Geetha Bolla

    2017-05-01

    Full Text Available Cocrystals of acemetacin drug (ACM with nicotinamide (NAM, p-aminobenzoic acid (PABA, valerolactam (VLM and 2-pyridone (2HP were prepared by melt crystallization and their X-ray crystal structures determined by high-resolution powder X-ray diffraction. The powerful technique of structure determination from powder data (SDPD provided details of molecular packing and hydrogen bonding in pharmaceutical cocrystals of acemetacin. ACM–NAM occurs in anhydrate and hydrate forms, whereas the other structures crystallized in a single crystalline form. The carboxylic acid group of ACM forms theacid–amide dimer three-point synthon R32(9R22(8R32(9 with three different syn amides (VLM, 2HP and caprolactam. The conformations of the ACM molecule observed in the crystal structures differ mainly in the mutual orientation of chlorobenzene fragment and the neighboring methyl group, being anti (type I or syn (type II. ACM hydrate, ACM—NAM, ACM–NAM-hydrate and the piperazine salt of ACM exhibit the type I conformation, whereas ACM polymorphs and other cocrystals adopt the ACM type II conformation. Hydrogen-bond interactions in all the crystal structures were quantified by calculating their molecular electrostatic potential (MEP surfaces. Hirshfeld surface analysis of the cocrystal surfaces shows that about 50% of the contribution is due to a combination of strong and weak O...H, N...H, Cl...H and C...H interactions. The physicochemical properties of these cocrystals are under study.

  11. Observation of parametric X-ray radiation in an anomalous diffraction region

    Energy Technology Data Exchange (ETDEWEB)

    Alexeyev, V.I., E-mail: vial@x4u.lebedev.ru [P.N. Lebedev Physical Institute RAS, 53 Leninskiy prospect, Moscow (Russian Federation); Belgorod National Research University, 85 Pobedy st., Belgorod (Russian Federation); Eliseyev, A.N., E-mail: elisseev@pluton.lpi.troitsk.ru [P.N. Lebedev Physical Institute RAS, 53 Leninskiy prospect, Moscow (Russian Federation); Belgorod National Research University, 85 Pobedy st., Belgorod (Russian Federation); Irribarra, E., E-mail: esteban.irribarra@epn.edu.ec [Escuela Politécnica Nacional, Ladrón de Guevara E11-253, Quito (Ecuador); Kishin, I.A., E-mail: ivan.kishin@mail.ru [P.N. Lebedev Physical Institute RAS, 53 Leninskiy prospect, Moscow (Russian Federation); Belgorod National Research University, 85 Pobedy st., Belgorod (Russian Federation); Kubankin, A.S., E-mail: kubankin@bsu.edu.ru [P.N. Lebedev Physical Institute RAS, 53 Leninskiy prospect, Moscow (Russian Federation); Belgorod National Research University, 85 Pobedy st., Belgorod (Russian Federation); Nazhmudinov, R.M., E-mail: fizeg@bk.ru [P.N. Lebedev Physical Institute RAS, 53 Leninskiy prospect, Moscow (Russian Federation); Belgorod National Research University, 85 Pobedy st., Belgorod (Russian Federation)

    2016-08-19

    A new possibility to expand the energy region of diffraction processes based on the interaction of relativistic charged particles with crystalline structures is presented. Diffracted photons related to parametric X-ray radiation produced by relativistic electrons are detected below the low energy threshold for the X-ray diffraction mechanism in crystalline structures for the first time. The measurements were performed during the interaction of 7 MeV electrons with a textured polycrystalline tungsten foil and a highly oriented pyrolytic graphite crystal. The experiment results are in good agreement with a developed model based on the PXR kinematical theory. The developed experimental approach can be applied to separate the contributions of real and virtual photons to the total diffracted radiation generated during the interaction of relativistic charged particles with crystalline targets. - Highlights: • Parametric X-ray radiation below the low energy threshold for diffraction of free X-rays. • Experimental separation of the contributions from different radiation mechanisms. • PXR from relativistic electrons in mosaic crystals and textured polycrystlas.

  12. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-06-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions.

  13. Combining operando synchrotron X-ray tomographic microscopy and scanning X-ray diffraction to study lithium ion batteries

    Science.gov (United States)

    Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa

    2016-01-01

    We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions. PMID:27324109

  14. Biological imaging by soft X-ray diffraction microscopy

    Science.gov (United States)

    Shapiro, David

    We have developed a microscope for soft x-ray diffraction imaging of dry or frozen hydrated biological specimens. This lensless imaging system does not suffer from the resolution or specimen thickness limitations that other short wavelength microscopes experience. The microscope, currently situated at beamline 9.0.1 of the Advanced Light Source, can collect diffraction data to 12 nm resolution with 750 eV photons and 17 nm resolution with 520 eV photons. The specimen can be rotated with a precision goniometer through an angle of 160 degrees allowing for the collection of nearly complete three-dimensional diffraction data. The microscope is fully computer controlled through a graphical user interface and a scripting language automates the collection of both two-dimensional and three-dimensional data. Diffraction data from a freeze-dried dwarf yeast cell, Saccharomyces cerevisiae carrying the CLN3-1 mutation, was collected to 12 run resolution from 8 specimen orientations spanning a total rotation of 8 degrees. The diffraction data was phased using the difference map algorithm and the reconstructions provide real space images of the cell to 30 nm resolution from each of the orientations. The agreement of the different reconstructions provides confidence in the recovered, and previously unknown, structure and indicates the three dimensionality of the cell. This work represents the first imaging of the natural complex refractive contrast from a whole unstained cell by the diffraction microscopy method and has achieved a resolution superior to lens based x-ray tomographic reconstructions of similar specimens. Studies of the effects of exposure to large radiation doses were also carried out. It was determined that the freeze-dried cell suffers from an initial collapse, which is followed by a uniform, but slow, shrinkage. This structural damage to the cell is not accompanied by a diminished ability to see small features in the specimen. Preliminary measurements on frozen

  15. X-ray diffraction patterns of thermally-reduced graphenes

    International Nuclear Information System (INIS)

    Ju, Hae-Mi; Choi, Sung-Ho; Huh, Seung-Hun

    2010-01-01

    Thermally-reduced graphenes (GPs) from graphene oxides (GOs) in the range of 200 - 800 .deg. C have been investigated by using X-ray diffraction (XRD). The temperature-dependent evolutions of the (002) peaks show that exfoliation of GO sheets occurs, along with wrinkling, at ∼200 .deg. C and that high-quality GPs are produced at ∼ 600 .deg. C (GP 600 ). These phenomena are explained by the vaporization of intercalated water molecules and the effective removal of the oxide groups of GO by thermal annealing, respectively. GP 600 exhibited a clean and sharp (002) peak corresponding to an interlayer distance of 3.392 A, which is close to that of conventional graphene (∼3.4 A). The structure of GP 600 is further discussed.

  16. Powder X-ray diffraction laboratory, Reston, Virginia

    Science.gov (United States)

    Piatak, Nadine M.; Dulong, Frank T.; Jackson, John C.; Folger, Helen W.

    2014-01-01

    The powder x-ray diffraction (XRD) laboratory is managed jointly by the Eastern Mineral and Environmental Resources and Eastern Energy Resources Science Centers. Laboratory scientists collaborate on a wide variety of research problems involving other U.S. Geological Survey (USGS) science centers and government agencies, universities, and industry. Capabilities include identification and quantification of crystalline and amorphous phases, and crystallographic and atomic structure analysis for a wide variety of sample media. Customized laboratory procedures and analyses commonly are used to characterize non-routine samples including, but not limited to, organic and inorganic components in petroleum source rocks, ore and mine waste, clay minerals, and glassy phases. Procedures can be adapted to meet a variety of research objectives.

  17. Simulating X-ray diffraction of textured films

    DEFF Research Database (Denmark)

    Breiby, Dag W.; Bunk, Oliver; Andreasen, Jens Wenzel

    2008-01-01

    Computationally efficient simulations of grazing-incidence X-ray diffraction (GIXD) are discussed, with particular attention given to textured thin polycrystalline films on supporting substrates. A computer program has been developed for simulating scattering from thin films exhibiting varying...... degrees of preferred orientation. One emphasized common case is that of a 'fibre' symmetry axis perpendicular to the sample plane, resulting from crystallites having one well defined crystal facet towards the substrate, but no preferred inplane orientation. Peak splitting caused by additional scattering......, the mathematically simplest possible descriptions are sought whenever feasible. The practical use of the program is demonstrated for a selected thin-film example, perylene, which is of relevance for organic electronics....

  18. X-ray diffraction study of choline chloride's β form

    International Nuclear Information System (INIS)

    Petrouleas, V.; Lemmon, R.M.; Christensen, A.

    1978-01-01

    The organic salt choline chloride exists in two crystalline polymorphs. One (the α form) is extraordinarily sensitive to ionizing radiation, the other (the β form) is not. The present report describes an x-ray diffraction study of the β form. The structure has been found to be highly disordered face centered cubic. A reasonable least-square refinement of the intensity data has been achieved in the centrosymmetric space group Fm3 or Fm3m by use of a molecular model with restrained bond lengths. The results show that in the β form the electronic density due to the choline cation is closely spaced around the N, so that hydrogen bonding to the chloride is unlikely. Comparison with infrared and NMR data indicates that the disordering is dynamic and can be ascribed to rotations of the choline ion around crystallographic symmetry axes. Possible connections of these results with the radiation stability of the β form are discussed

  19. Phosphor Scanner For Imaging X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Hecht, Diana L.; Witherow, William K.

    1992-01-01

    Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

  20. X-ray diffraction and X-ray standing-wave study of the lead stearate film structure

    Energy Technology Data Exchange (ETDEWEB)

    Blagov, A. E.; Dyakova, Yu. A.; Kovalchuk, M. V.; Kohn, V. G.; Marchenkova, M. A.; Pisarevskiy, Yu. V.; Prosekov, P. A., E-mail: prosekov@crys.ras.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2016-05-15

    A new approach to the study of the structural quality of crystals is proposed. It is based on the use of X-ray standing-wave method without measuring secondary processes and considers the multiwave interaction of diffraction reflections corresponding to different harmonics of the same crystallographic reflection. A theory of multiwave X-ray diffraction is developed to calculate the rocking curves in the X-ray diffraction scheme under consideration for a long-period quasi-one-dimensional crystal. This phase-sensitive method is used to study the structure of a multilayer lead stearate film on a silicon substrate. Some specific structural features are revealed for the surface layer of the thin film, which are most likely due to the tilt of the upper layer molecules with respect to the external normal to the film surface.

  1. Nanostructured diffractive optical devices for soft X-ray microscopes

    CERN Document Server

    Hambach, D; Schneider, G

    2001-01-01

    The new transmission X-ray microscope (TXM) installed at the BESSY II electron storage ring uses an off-axis transmission zone plate (OTZ) as diffractive and focusing element of the condenser-monochromator setup. A high resolution micro-zone plate (MZP) forms a magnified image on a CCD-detector. Both, the OTZ with an active area of up to 24 mm sup 2 and the MZP with zone widths as small as 25 nm are generated by a process including electron beam lithography (EBL), dry etching and subsequent electroplating of nickel on top of silicon membrane substrates with about 100-150 nm thickness. The combination of a larger zone width and the usage of nickel zone structures allows to increase the diffraction efficiency of the condenser element at least by a factor of 3 compared to the earlier used KZP7 condenser zone plate in the TXM at BESSY I. Groove diffraction efficiencies of 21.6% and 14.7% were measured for MZP objectives with 40 and 25 nm outermost zone width, respectively.

  2. Fundamentals of powder x-ray diffraction practice

    International Nuclear Information System (INIS)

    Raftery, T.

    2002-01-01

    Full text: The goal of powder Xray diffraction is to gain information about a specimen or sample. Key aspects of this goal are 1. the sample selection, preparation and presentation; 2. the data collection process and conditions; 3. the interaction between these and the interpretation of the data. The 'ideal' powder (or polycrystalline) xray diffraction sample is fine grained, randomly orientated, homogenous and representative. There exists standard sample selection and preparation techniques for powders - sometimes however, the required information must be gained by alternate sample selection and preparation techniques. While there are few variables in the data collection process, there are some significant ones such as matching diffractometer resolution and intensity to the data collection goal whether that is phase identity, quantitative analysis or structure refinement, etc. There are also options of optical arrangement (Bragg-Brintano versus parallel beam versus Debye-Scherrer). One important aspect of the collection process is the assessment of the data quality. Powder xray diffraction has many applications from the straight-forward confirmation of phase identity and purity to structural analysis. Some of these applications will be considered and the interaction between the goal of the application and aspects of sample selection. Copyright (2002) Australian X-ray Analytical Association Inc

  3. Diffracted X-ray tracking for monitoring intramolecular motion in individual protein molecules using broad band X-ray

    Energy Technology Data Exchange (ETDEWEB)

    Ichiyanagi, Kouhei; Sasaki, Yuji C. [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan); Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Sekiguchi, Hiroshi; Hoshino, Masato; Kajiwara, Kentaro; Senba, Yasunori; Ohashi, Haruhiko; Ohta, Noboru [Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan); Hoshisashi, Kentaro; Jae-won, Chang; Tokue, Maki; Matsushita, Yufuku [Department of Advanced Materials Science, Graduate School of Frontier Sciences, The University of Tokyo, 609 Kiban Building 5-1-5 Kashiwanoha, Kahiwashi, Chiba 277-8561 (Japan); Nishijima, Masaki; Inoue, Yoshihisa [Department of Applied Chemistry and Office for University-Industry Collaboration, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Yagi, Naoto [Japan Science and Technology Agency, CREST, CREST, Sasaki-Team, 609 Kiban Building, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8561 (Japan); Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2013-10-15

    Diffracted X-ray tracking (DXT) enables the tilting and twisting motions of single protein molecules to be monitored with micro- to milliradian resolution using a highly brilliant X-ray source with a wide energy bandwidth. We have developed a technique to monitor single molecules using gold nanocrystals attached to individual protein molecules using the BL28B2 beamline at SPring-8. In this paper we present the installation of a single toroidal X-ray mirror at BL28B2 to focus X-rays in an energy range of 10–20 keV (△E/E = 82% for an X-ray with a wide energy bandwidth). With this beamline we tracked diffraction spots from gold nanocrystals over a wide angle range than that using quasi-monochromatic X-rays. Application of the wide angle DXT technique to biological systems enabled us to observe the on-site motions of single protein molecules that have been functionalized in vivo. We further extend the capability of DXT by observing the fractional tilting and twisting motions of inner proteins under various conditions. As a proof of this methodology and to determine instrumental performance the intramolecular motions of a human serum albumin complex with 2-anthracenecarboxylic acid was investigated using the BL28B2 beamline. The random tilting and twisting intramolecular motions are shown to be directly linked to the movement of individual protein molecules in the buffer solution.

  4. Observation of sagittal X-ray diffraction by surface acoustic waves in Bragg geometry.

    Science.gov (United States)

    Vadilonga, Simone; Zizak, Ivo; Roshchupkin, Dmitry; Evgenii, Emelin; Petsiuk, Andrei; Leitenberger, Wolfram; Erko, Alexei

    2017-04-01

    X-ray Bragg diffraction in sagittal geometry on a Y-cut langasite crystal (La 3 Ga 5 SiO 14 ) modulated by Λ = 3 µm Rayleigh surface acoustic waves was studied at the BESSY II synchrotron radiation facility. Owing to the crystal lattice modulation by the surface acoustic wave diffraction, satellites appear. Their intensity and angular separation depend on the amplitude and wavelength of the ultrasonic superlattice. Experimental results are compared with the corresponding theoretical model that exploits the kinematical diffraction theory. This experiment shows that the propagation of the surface acoustic waves creates a dynamical diffraction grating on the crystal surface, and this can be used for space-time modulation of an X-ray beam.

  5. Femtosecond x-ray photoelectron diffraction on gas-phase dibromobenzene molecules

    International Nuclear Information System (INIS)

    Rolles, D; Boll, R; Epp, S W; Erk, B; Foucar, L; Hömke, A; Adolph, M; Gorkhover, T; Aquila, A; Chapman, H N; Coppola, N; Delmas, T; Gumprecht, L; Holmegaard, L; Bostedt, C; Bozek, J D; Coffee, R; Decleva, P; Filsinger, F; Johnsson, P

    2014-01-01

    We present time-resolved femtosecond photoelectron momentum images and angular distributions of dissociating, laser-aligned 1,4-dibromobenzene (C 6 H 4 Br 2 ) molecules measured in a near-infrared pump, soft-x-ray probe experiment performed at an x-ray free-electron laser. The observed alignment dependence of the bromine 2p photoelectron angular distributions is compared to density functional theory calculations and interpreted in terms of photoelectron diffraction. While no clear time-dependent effects are observed in the angular distribution of the Br(2p) photoelectrons, other, low-energy electrons show a pronounced dependence on the time delay between the near-infrared laser and the x-ray pulse. (paper)

  6. Extended X-ray absorption fine structure and X-ray diffraction studies on supported Ni catalysts

    International Nuclear Information System (INIS)

    Aldea, N.; Marginean, P.; Yaning, Xie; Tiandou, Hu; Tao, Liu; Wu, Zhongua; ZhenYa, Dai

    1999-01-01

    In the first part of this paper, we present a study based on EXAFS spectroscopy. This method can yield structural information about the local environment around a specific atomic constituent in the amorphous materials, the location and chemical state of any catalytic atom on any support or point defect structures, in alloys and composites. EXAFS is a specific technique of the scattering of X-ray on materials. The present study is aimed toward elucidation of the local structure of Ni atoms and their interaction with oxide support. The second goal of the paper consists in X-ray diffraction on the same samples. X-ray diffraction method that is capable to determine average particle size, microstrains, probability of faults as well as particle size distribution function of supported Ni catalysts is presented. The method is based on the Fourier analysis of a single X-Ray diffraction profile. The results obtained on supported nickel catalysts, which are used in H/D isotopic exchange reactions are reported. The global structure is obtained with a new fitting method based on the Generalised Fermi Function facilities for approximation and Fourier transform of the experimental X-Ray line profiles. Both types of measurements were performed on Beijing Synchrotron Radiation Facilities (BSRF). (authors)

  7. Time-dependent Takagi-Taupin eikonal theory and applications in the subpicosecond manipulation of X-rays

    International Nuclear Information System (INIS)

    Adams, Bernhard W.

    2004-01-01

    A time-dependent version of the Takagi-Taupin theory of X-ray diffraction is derived in a unified space-time approach, which is particularly applicable to X-ray diffraction in a crystal that is undergoing rapid change on the subpicosecond, and even few-femtosecond, time scale. The theory is applied to the proposal of a class of X-ray optical elements for the subpicosecond manipulation of X-rays

  8. X-ray diffraction studies of NbTe 2 single crystal

    Indian Academy of Sciences (India)

    The composition of the grown crystals was confirmed on the basis of energy dispersive analysis by X-ray (EDAX) and remaining structural characterization was also accomplished by X-ray diffraction (XRD) studies. Lattice parameters, volume and X-ray density have been carried out for the grown crystals. The particle size ...

  9. Ultrafast coherent diffractive imaging of nanoparticles using X-ray free-electron laser radiation

    International Nuclear Information System (INIS)

    Kassemeyer, Stephan

    2014-01-01

    Coherent diffractive imaging with X-ray free-electron lasers (X-FEL) promises high-resolution structure determination of single microscopic particles without the need for crystallization. The diffraction signal of small samples can be very weak, a difficulty that can not be countered by merely increasing the number of photons because the sample would be damaged by a high absorbed radiation dose. Traditional X-ray crystallography avoids this problem by bringing many sample particles into a periodic arrangement, which amplifies the individual signals while distributing the absorbed dose. Depending on the sample, however, crystallization can be very difficult or even impossible. This thesis presents algorithms for a new imaging approach using X-FEL radiation that works with single, non-crystalline sample particles. X-FELs can deliver X-rays with a peak brilliance many orders of magnitude higher than conventional X-ray sources, compensating for their weak interaction cross sections. At the same time, FELs can produce ultra-short pulses down to a few femtoseconds. In this way it is possible to perform ultra-fast imaging, essentially ''freezing'' the atomic positions in time and terminating the imaging process before the sample is destroyed by the absorbed radiation. This thesis primarily focuses on the three-dimensional reconstruction of single (and not necessarily crystalline) particles using coherent diffractive imaging at X-FELs: in order to extract three-dimensional information from scattering data, two-dimensional diffraction patterns from many different viewing angles must be combined. Therefore, the diffraction signal of many identical sample copies in random orientations is measured. The main result of this work is a globally optimal algorithm that can recover the sample orientations solely based on the diffraction signal, enabling three-dimensional imaging for arbitrary samples. The problem of finding three-dimensional orientations is

  10. Sequential x-ray diffraction topography at 1-BM x-ray optics testing beamline at the advanced photon source

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav, E-mail: sstoupin@aps.anl.gov; Shvyd’ko, Yuri; Trakhtenberg, Emil; Liu, Zunping; Lang, Keenan; Huang, Xianrong; Wieczorek, Michael; Kasman, Elina; Hammonds, John; Macrander, Albert; Assoufid, Lahsen [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2016-07-27

    We report progress on implementation and commissioning of sequential X-ray diffraction topography at 1-BM Optics Testing Beamline of the Advanced Photon Source to accommodate growing needs of strain characterization in diffractive crystal optics and other semiconductor single crystals. The setup enables evaluation of strain in single crystals in the nearly-nondispersive double-crystal geometry. Si asymmetric collimator crystals of different crystallographic orientations were designed, fabricated and characterized using in-house capabilities. Imaging the exit beam using digital area detectors permits rapid sequential acquisition of X-ray topographs at different angular positions on the rocking curve of a crystal under investigation. Results on sensitivity and spatial resolution are reported based on experiments with high-quality Si and diamond crystals. The new setup complements laboratory-based X-ray topography capabilities of the Optics group at the Advanced Photon Source.

  11. High-Resolution Detector For X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Withrow, William K.; Pusey, Marc L.; Yost, Vaughn H.

    1988-01-01

    Proposed x-ray-sensitive imaging detector offers superior spatial resolution, counting-rate capacity, and dynamic range. Instrument based on laser-stimulated luminescence and reusable x-ray-sensitive film. Detector scans x-ray film line by line. Extracts latent image in film and simultaneously erases film for reuse. Used primarily for protein crystallography. Principle adapted to imaging detectors for electron microscopy and fluorescence spectroscopy and general use in astronomy, engineering, and medicine.

  12. Performances for confocal X-ray diffraction technology based on polycapillary slightly focusing X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hehe; Liu, Zhiguo [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi, E-mail: stxbeijing@163.com [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Peng, Song [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Ma, Yongzhong [Center for Disease Control and Prevention of Beijing, Beijing 100013 (China); Sun, Weiyuan; Li, Yude; Lin, Xiaoyan; Zhao, Weigang; Zhao, Guangcui; Luo, Ping; Pan, Qiuli; Ding, Xunliang [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2013-09-21

    The confocal X-ray diffraction (XRD) technology based on a polycapillary slightly focusing X-ray lens (PSFXRL) in excitation channel and a polycapillary parallel X-ray lens (PPXRL) with a long input focal distance in detection channel was developed. The output focal spot of the PSFXRL and the input focal spot of the PPXRL were adjusted in confocal configuration, and only the X-rays from the volume overlapped by these foci could be accordingly detected. This confocal configuration was helpful in decreasing background. The convergence of the beam focused by the PSFXRL and divergence of the beam which could be collected by the PPXRL with a long input focal distance were both about 9 mrad at 8 keV. This was helpful in improving the resolution of lattice spacing of this confocal XRD technology. The gain in power density of such PSFXRL and PPXRL was about 120 and 7 at 11 keV, respectively, which was helpful in using the low power source to perform XRD analysis efficiently. The performances of this confocal XRD technology were provided, and some common plastics were analyzed. The experimental results demonstrated that the confocal diffraction technology base on polycapillary slightly focusing X-ray optics had wide potential applications.

  13. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Flesher, A.C.; Bryant, C.J.; Lincoln, A.D.; Tucker, P.A.; Swanton, S.W.

    1986-08-01

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described:- the Mark I and the Mark II. Both use a bidimensionally sensitive Multiwire proportional counter as the basic X-ray image transducer coupled to a digital microcomputer system. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multi-frame exposures. (author)

  14. Slow scan sit detector for x-ray diffraction studies using synchrotron radiation

    International Nuclear Information System (INIS)

    Milch, J.R.

    1978-01-01

    A TV-type x-ray detector using a SIT vidicon has been used for biological diffraction studies at the EMBL outstation at DESY, Hamburg, Germany. The detector converts the two-dimensional diffraction pattern to a charge pattern on the vidicon target, which is read out in the slow-scan mode. This detector has high DOE, no count-rate limit, and is simple and inexpensive to construct. Radiation from the storage ring DORIS was used to study the structure of live muscle at various phases of contraction. Typically the count-rate on the detector was 10 6 x-rays/sec and a total exposure of a few seconds was needed to record the weak diffraction from muscle. This compares with usual exposure times of several hours using a rotating anode generator and film

  15. Grain orientation mapping of passivated aluminum interconnect lines with X-ray micro-diffraction

    International Nuclear Information System (INIS)

    Chang, C.H.; Patel, J.R.; MacDowell, A.A.; Padmore, H.A.; Thompson, A.C.

    1998-01-01

    A micro x-ray diffraction facility is under development at the Advanced Light Source. Spot sizes are typically about 1-microm size generated by means of grazing incidence Kirkpatrick-Baez focusing mirrors. Photon energy is either white of energy range 6--14 keV or monochromatic generated from a pair of channel cut crystals. Laue diffraction pattern from a single grain in a passivated 2-microm wide bamboo structured Aluminum interconnect line has been recorded. Acquisition times are of the order of seconds. The Laue pattern has allowed the determination of the crystallographic orientation of individual grains along the line length. The experimental and analysis procedure used is described, as is the latest grain orientation result. The impact of x-ray micro-diffraction and its possible future direction are discussed in the context of other developments in the area of electromigration, and other technological problems

  16. Grain orientation mapping of passivated aluminum interconnect lines by x-ray micro-diffraction

    International Nuclear Information System (INIS)

    Chang, C. H.; Patel, J. R.; MacDowell, A. A.; Padmore, H. A.; Thompson, A. C.

    1998-01-01

    A micro x-ray diffraction facility is under development at the Advanced Light Source. Spot sizes are typically about 1-μm size generated by means of grazing incidence Kirkpatrick-Baez focusing mirrors. Photon energy is either white of energy range 6-14 keV or monochromatic generated from a pair of channel cut crystals. Laue diffraction pattern from a single grain in a passivated 2-μm wide bamboo structured Aluminum interconnect line has been recorded. Acquisition times are of the order of seconds. The Laue pattern has allowed the determination of the crystallographic orientation of individual grains along the line length. The experimental and analysis procedure used is described, as is the latest grain orientation result. The impact of x-ray micro-diffraction and its possible future direction are discussed in the context of other developments in the area of electromigration, and other technological problems

  17. Cyclic olefin homopolymer-based microfluidics for protein crystallization and in situ X-ray diffraction

    International Nuclear Information System (INIS)

    Emamzadah, Soheila; Petty, Tom J.; De Almeida, Victor; Nishimura, Taisuke; Joly, Jacques; Ferrer, Jean-Luc; Halazonetis, Thanos D.

    2009-01-01

    A cyclic olefin homopolymer-based microfluidics system has been established for protein crystallization and in situ X-ray diffraction. Microfluidics is a promising technology for the rapid identification of protein crystallization conditions. However, most of the existing systems utilize silicone elastomers as the chip material which, despite its many benefits, is highly permeable to water vapour. This limits the time available for protein crystallization to less than a week. Here, the use of a cyclic olefin homopolymer-based microfluidics system for protein crystallization and in situ X-ray diffraction is described. Liquid handling in this system is performed in 2 mm thin transparent cards which contain 500 chambers, each with a volume of 320 nl. Microbatch, vapour-diffusion and free-interface diffusion protocols for protein crystallization were implemented and crystals were obtained of a number of proteins, including chicken lysozyme, bovine trypsin, a human p53 protein containing both the DNA-binding and oligomerization domains bound to DNA and a functionally important domain of Arabidopsis Morpheus’ molecule 1 (MOM1). The latter two polypeptides have not been crystallized previously. For X-ray diffraction analysis, either the cards were opened to allow mounting of the crystals on loops or the crystals were exposed to X-rays in situ. For lysozyme, an entire X-ray diffraction data set at 1.5 Å resolution was collected without removing the crystal from the card. Thus, cyclic olefin homopolymer-based microfluidics systems have the potential to further automate protein crystallization and structural genomics efforts

  18. X-ray diffraction imaging of material microstructures

    KAUST Repository

    Varga, Laszlo; Varga, Bonbien; Calo, Victor

    2016-01-01

    Various examples are provided for x-ray imaging of the microstructure of materials. In one example, a system for non-destructive material testing includes an x-ray source configured to generate a beam spot on a test item; a grid detector configured

  19. X-ray diffraction analysis of mudstone from nw sudan

    International Nuclear Information System (INIS)

    Salih, Suad Z.Elabdeen

    1997-03-01

    This study deals with the theoretical and experimental aspects of the x-ray diffraction technique (XRD). The XRD technique is used to investigate fine structure of matter, and it is most efficient method for the determination of the mineralogical composition of rocks. The XRD technique is used also to investigate the clay mineralogical of mud-stones of the Nubian sandstones of north western Sudan. The XRD results revealed that the mud-stone samples are composed, in decreasing abundance's of kaolinite, smectite, chlorite and illite. Non-clay minerals reported include quartz, feldspars and geothite. Kaolinite dominates in most of samples with percentages ranging between 78-96%. Smectite comes second in abundance and ranges between 10-24%, followed by chlorite and illite which showed the lowest abundance's. The dominance of kaolinite over smectite indicates that intense chemical weathering and leaching occurred under warm humid climate interrupted by dry periods. Most probably these clay minerals were produced by inheritance and partly by neo formation. The variation of the chemical composition of these mud stones is due basically to differences in clay mineralogy which was controlled by source rock geology, weathering physicochemical behavior of elements, local environment and climatic condition in the past. (Author)

  20. Federated repositories of X-ray diffraction images.

    Science.gov (United States)

    Androulakis, Steve; Schmidberger, Jason; Bate, Mark A; DeGori, Ross; Beitz, Anthony; Keong, Cyrus; Cameron, Bob; McGowan, Sheena; Porter, Corrine J; Harrison, Andrew; Hunter, Jane; Martin, Jennifer L; Kobe, Bostjan; Dobson, Renwick C J; Parker, Michael W; Whisstock, James C; Gray, Joan; Treloar, Andrew; Groenewegen, David; Dickson, Neil; Buckle, Ashley M

    2008-07-01

    There is a pressing need for the archiving and curation of raw X-ray diffraction data. This information is critical for validation, methods development and improvement of archived structures. However, the relatively large size of these data sets has presented challenges for storage in a single worldwide repository such as the Protein Data Bank archive. This problem can be avoided by using a federated approach, where each institution utilizes its institutional repository for storage, with a discovery service overlaid. Institutional repositories are relatively stable and adequately funded, ensuring persistence. Here, a simple repository solution is described, utilizing Fedora open-source database software and data-annotation and deposition tools that can be deployed at any site cheaply and easily. Data sets and associated metadata from federated repositories are given a unique and persistent handle, providing a simple mechanism for search and retrieval via web interfaces. In addition to ensuring that valuable data is not lost, the provision of raw data has several uses for the crystallographic community. Most importantly, structure determination can only be truly repeated or verified when the raw data are available. Moreover, the availability of raw data is extremely useful for the development of improved methods of image analysis and data processing.

  1. Standing surface acoustic waves in LiNbO3 studied by time resolved X-ray diffraction at Petra III

    Directory of Open Access Journals (Sweden)

    T. Reusch

    2013-07-01

    Full Text Available We have carried out time resolved stroboscopic diffraction experiments on standing surface acoustic waves (SAWs of Rayleigh type on a LiNbO3 substrate. A novel timing system has been developed and commissioned at the storage ring Petra III of Desy, allowing for phase locked stroboscopic diffraction experiments applicable to a broad range of timescales and experimental conditions. The combination of atomic structural resolution with temporal resolution on the picosecond time scale allows for the observation of the atomistic displacements for each time (or phase point within the SAW period. A seamless transition between dynamical and kinematic scattering regimes as a function of the instantaneous surface amplitude induced by the standing SAW is observed. The interpretation and control of the experiment, in particular disentangling the diffraction effects (kinematic to dynamical diffraction regime from possible non-linear surface effects is unambiguously enabled by the precise control of phase between the standing SAW and the synchrotron bunches. The example illustrates the great flexibility and universality of the presented timing system, opening up new opportunities for a broad range of time resolved experiments.

  2. X-ray topography under conditions of monochromatic spherical wave diffraction

    International Nuclear Information System (INIS)

    Aristov, V.V.; Polovinkina, V.I.; Ibhikawa, Tetsuya; Kiduta, Seishi.

    1981-01-01

    An X-ray topographic scheme was developed in which there is a large distance between the X-ray source and the specimen. A monochromatic X-ray beam with an angular divergence 6 x 10 - 5 rad obtained by double successive diffraction in the (n 1 , +n 2 ) setting was used. This scheme enables diffraction focusing of a weakly absorbed wave field onto the exit surface of the crystal to be performed. Topographs of a wedge-shaped silicon crystal were obtained. Interference effects such as focusing, anomalous and ordinary Pendelloesung effects peculiar to X-ray spherical wave diffraction were observed in the topographs with high resolution. (author)

  3. Characterization of Polycrystalline Materials Using Synchrotron X-ray Imaging and Diffraction Techniques

    DEFF Research Database (Denmark)

    Ludwig, Wolfgang; King, A.; Herbig, M.

    2010-01-01

    The combination of synchrotron radiation x-ray imaging and diffraction techniques offers new possibilities for in-situ observation of deformation and damage mechanisms in the bulk of polycrystalline materials. Minute changes in electron density (i.e., cracks, porosities) can be detected using...... propagation based phase contrast imaging, a 3-D imaging mode exploiting the coherence properties of third generation synchrotron beams. Furthermore, for some classes of polycrystalline materials, one may use a 3-D variant of x-ray diffraction imaging, termed x-ray diffraction contrast tomography. X-ray...

  4. X-ray diffraction investigation of self-annealing in nanocrystalline copper electrodeposits

    DEFF Research Database (Denmark)

    Pantleon, Karen; Somers, Marcel A. J.

    2006-01-01

    X-ray diffraction analysis and electrical resistivity measurements were conducted simultaneously for in-situ examination of self-annealing in copper electrodeposits. Considerable growth of the as-deposited nano-sized crystallites occurs with time and the crystallographic texture changes by multip...... twinning during self-annealing. The kinetics of self-annealing depends on the layer thickness as well as on the orientation and/or the size of the as-deposited crystallites. (c) 2006 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.......X-ray diffraction analysis and electrical resistivity measurements were conducted simultaneously for in-situ examination of self-annealing in copper electrodeposits. Considerable growth of the as-deposited nano-sized crystallites occurs with time and the crystallographic texture changes by multiple...

  5. Liquid ammonia: Molecular correlation functions from x-ray diffraction

    International Nuclear Information System (INIS)

    Narten, A.H.

    1977-01-01

    For nearly spherical molecules the x-ray scattering from liquids yields structure and correlation functions for molecular centers. The distribution of electron density in an ammonia molecular is very nearly spherical, and orientational correlation between molecules in the liquid is not ''seen'' by x rays. Structure and correlation functions for molecular centers (nitrogen atoms) are derived from x-ray data on liquid NH 3 at 4 degreeC and tabulated. They provide a sensitive test for future work on a molecular theory of liquid ammonia

  6. Modelling the X-ray powder diffraction of nitrogen-expanded austenite using the Debye formula

    DEFF Research Database (Denmark)

    Oddershede, Jette; Christiansen, Thomas; Ståhl, Kenny

    2008-01-01

    Stress-free and homogeneous samples of nitrogen-expanded austenite, a defect-rich f.c.c. structure with a high interstitial nitrogen occupancy (between 0.36 and 0.61), have been studied using X-ray powder diffraction and Debye simulations. The simulations confirm the presence of deformation...... to be indistinguishable to X-ray powder diffraction....

  7. X-Ray Diffraction and the Discovery of the Structure of DNA

    Science.gov (United States)

    Crouse, David T.

    2007-01-01

    A method is described for teaching the analysis of X-ray diffraction of DNA through a series of steps utilizing the original methods used by James Watson, Francis Crick, Maurice Wilkins and Rosalind Franklin. The X-ray diffraction pattern led to the conclusion of the basic helical structure of DNA and its dimensions while basic chemical principles…

  8. Secondary extinction in cylindrical and spherical crystals for X-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Hu Huachen; Li Zhaohuan; Yang Bin; Shen Caiwan

    2001-01-01

    The distribution of the reflection power ratio for a neutron or x-ray diffracted from a cylindrical crystal immersed in an homogenous incident beam is obtained by the numerical solution of the transfer equations for the first time. The profile well reflects all the physical properties of the absorption and extinction behaviour in the crystals. A systematic investigation of the secondary extinction for cylindrical and spherical crystals was carried out based on these results

  9. Qualitative analysis of powder x-ray diffraction data

    International Nuclear Information System (INIS)

    Raftery, T.

    1999-01-01

    based methods of considering significant lines such as with the Hanawalt, Fink and alphabetical index; computer based search-match based on FOM and the more recent graphically based full pattern methods of phase identification. No single approach is foolproof. a range of techniques is recommended if a high level of success is required. Copyright (1999) Australian X-ray Analytical Association Inc

  10. New opportunities for 3D materials science of polycrystalline materials at the micrometre lengthscale by combined use of X-ray diffraction and X-ray imaging

    DEFF Research Database (Denmark)

    Ludwig, W.; King, A.; Reischig, P.

    2009-01-01

    Non-destructive, three-dimensional (3D) characterization of the grain structure in mono-phase polycrystalline materials is an open challenge in material science. Recent advances in synchrotron based X-ray imaging and diffraction techniques offer interesting possibilities for mapping 3D grain shapes....... A recent extension of this methodology, termed X-ray diffraction contrast tomography (DCT), combines the principles of X-ray diffraction imaging, three-dimensional X-ray diffraction microscopy (3DXRD) and image reconstruction from projections. DCT provides simultaneous access to 3D grain shape...

  11. Two digital X-ray imaging systems for applications in X-ray diffraction

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.; Flesher, A.C.; Tucker, P.A.; Swanton, S.W.

    1987-01-01

    Two digital X-ray imaging systems developed at the Rutherford Appleton Laboratory are described: the Mark I and the Mark II. Both use a bidimensionally sensitive multiwire proportional counter (MWPC) as the basic X-ray image transducer coupled, in the case of the Mark I to a Digital LSI 11-23 microcomputer system via CAMAC, and in the case of the Mark II to a Digital LSI 11-73 microcomputer system via custom-built data acquisition hardware mounted directly on the Q-bus of the microcomputer. The Mark I system provides the advantages of high speed, high sensitivity digital imaging directly into the computer with the potential for software control of the sample orientation and environment. The Mark II system adds the novel features of signal averaging and multiframe exposures. The dedicated digital memories have a resolution of 512x512 pixels of 16 bits, matching well to the spatial resolution of the xenon-filled MWPC (0.5 mm fwhm over an aperture of 200 mm x 200 mm). A 512x512x4 bit video graphics system displays the images in grey scales or colour. (orig.)

  12. The phase problem and perspectives of surface X-ray diffraction

    International Nuclear Information System (INIS)

    Tajiri, Hiroo; Takahashi, Toshio

    2009-01-01

    The emergence of synchrotron radiation sources has accelerated the application of diffraction techniques to surface sciences. Surface X-ray diffraction has become the state-of-the-art technique for determining ordered structures of atoms on crystal surfaces. We introduce surface X-ray diffraction briefly from the historical point of view and describe the concept that not only determine constellation of surface atoms but also view surface atoms as image. The progress in experimental and theoretical studies of surface X-ray diffraction including crystallographic direct methods is reviewed. (author)

  13. Three-dimensional visualization of a human chromosome using coherent x-ray diffraction

    International Nuclear Information System (INIS)

    Nishino, Yoshinori; Ishikawa, Tetsuya; Takahashi, Yukio; Imamoto, Naoko; Maeshima, Kazuhiro

    2010-01-01

    We succeeded in observing a human chromosome in two- and three-dimensions using x-ray diffraction microscopy. X-ray diffraction microscopy is a lens-less imaging technique utilizing coherent x-ray diffraction, and can overcome various limitations in conventional lens-based x-ray microscopy. Biological applications of the method have been limited to 2D observation, and 3D observation has been long waited. We found that the reconstructed chromosome images contain high-density axial structure, which has not been observed under unstained or unlabeled conditions. The result experimentally demonstrates the effectiveness of x-ray diffraction microscopy in observing internal structures of unstained biological samples with high image contrast. (author)

  14. Ultrafast lattice dynamics in photoexcited nanostructures. Femtosecond X-ray diffraction with optimized evaluation schemes

    International Nuclear Information System (INIS)

    Schick, Daniel

    2013-01-01

    Within the course of this thesis, I have investigated the complex interplay between electron and lattice dynamics in nanostructures of perovskite oxides. Femtosecond hard X-ray pulses were utilized to probe the evolution of atomic rearrangement directly, which is driven by ultrafast optical excitation of electrons. The physics of complex materials with a large number of degrees of freedom can be interpreted once the exact fingerprint of ultrafast lattice dynamics in time-resolved X-ray diffraction experiments for a simple model system is well known. The motion of atoms in a crystal can be probed directly and in real-time by femtosecond pulses of hard X-ray radiation in a pump-probe scheme. In order to provide such ultrashort X-ray pulses, I have built up a laser-driven plasma X-ray source. The setup was extended by a stable goniometer, a two-dimensional X-ray detector and a cryogen-free cryostat. The data acquisition routines of the diffractometer for these ultrafast X-ray diffraction experiments were further improved in terms of signal-to-noise ratio and angular resolution. The implementation of a high-speed reciprocal-space mapping technique allowed for a two-dimensional structural analysis with femtosecond temporal resolution. I have studied the ultrafast lattice dynamics, namely the excitation and propagation of coherent phonons, in photoexcited thin films and superlattice structures of the metallic perovskite SrRuO 3 . Due to the quasi-instantaneous coupling of the lattice to the optically excited electrons in this material a spatially and temporally well-defined thermal stress profile is generated in SrRuO 3 . This enables understanding the effect of the resulting coherent lattice dynamics in time-resolved X-ray diffraction data in great detail, e.g. the appearance of a transient Bragg peak splitting in both thin films and superlattice structures of SrRuO 3 . In addition, a comprehensive simulation toolbox to calculate the ultrafast lattice dynamics and the

  15. Measurement of thickness of thin films by the X-ray diffraction method

    International Nuclear Information System (INIS)

    Srinivasan, C.; Balasingh, C.; Singh, A.K.

    1979-07-01

    X-ray diffraction method can be used to measure the thickness of thin films (coatings). The principle and the experimental details of the x-ray diffraction methods are described. The intensities of the diffracted beams are derived assuming a random orientation of the crystallites in the diffracting medium. Consequently, the expressions are not valid when the sample has preferred orientation. To check the performance of the method, thicknesses of nickel deposits on mild steel plates were determined by the x-ray diffraction method and the results compared with those obtained by the weighing method and metallographic examination. The weighing method which gives an accuracy of +- 0.1 micron is taken as the standard. The x-ray diffraction methods and the metallographic examinations give values within +- 1 micron of the value obtained by the weighing method. (author)

  16. Optimization of an X-ray diffraction imaging system for medical and security applications

    International Nuclear Information System (INIS)

    Marticke, Fanny

    2016-01-01

    X-ray diffraction imaging is a powerful noninvasive technique to identify or characterize different materials. Compared to traditional techniques using X-ray transmission, it allows to extract more material characteristic information, such as the Bragg peak positions for crystalline materials as well as the molecular form factor for amorphous materials. The potential of this technique has been recognized by many researchers and numerous applications such as luggage inspection, nondestructive testing, drug detection and biological tissue characterization have been proposed. The method of energy dispersive X-ray diffraction (EDXRD) is particularly suited for this type of applications as it allows the use of a conventional X-ray tube, the acquisition of the whole spectrum at the same time and parallelized architectures to inspect an entire object in a reasonable time. The purpose of the present work is to optimize the whole material characterization chain. Optimization comprises two aspects: optimization of the acquisition system and of data processing. The last one concerns especially the correction of diffraction pattern degraded by acquisition process. Reconstruction methods are proposed and validated on simulated and experimental spectra. System optimization is realized using figures of merit such as detective quantum efficiency (DQE), contrast to noise ratio (CNR) and receiver operating characteristic (ROC) curves.The first chosen application is XRD based breast imaging which aims to distinguish cancerous tissues from healthy tissues. Two non-multiplexed collimation configurations combining EDXRD and ADXRD are proposed after optimization procedure. A simulation study of the whole system and a breast phantom was realized to determine the required dose to detect a 4 mm carcinoma nodule. The second application concerns detection of illicit materials during security check. The possible benefit of a multiplexed collimation system was examined. (author) [fr

  17. Detectors for X-ray diffraction and scattering: a user's overview

    International Nuclear Information System (INIS)

    Bruegemann, Lutz; Gerndt, E.K.E.

    2004-01-01

    An overview of the applications of X-ray detectors to material research is given. Four experimental techniques and their specific detector requirements are described. Detector types are classified and critical parameters described in the framework of X-ray diffraction and X-ray scattering experiments. The article aims at building a bridge between detector end-users and detector developers. It gives limits of critical detector parameters, like angular resolution, energy resolution, dynamic range, and active area

  18. Time resolved x-ray pinhole photography of compressed laser fusion targets

    International Nuclear Information System (INIS)

    Attwood, D.T.

    1976-01-01

    Use of the Livermore x-ray streak camera to temporally record x-ray pinhole images of laser compressed targets is described. Use is made of specially fabricated composite x-ray pinholes which are near diffraction limited for 6 A x-rays, but easily aligned with a He--Ne laser of 6328 A wavelength. With a 6 μm x-ray pinhole, the overall system can be aligned to 5 μm accuracy and provides implosion characteristics with space--time resolutions of approximately 6 μm and 15 psec. Acceptable criteria for pinhole alignment, requisite x-ray flux, and filter characteristics are discussed. Implosion characteristics are presented from our present experiments with 68 μm diameter glass microshell targets and 0.45 terawatt, 70 psec Nd laser pulses. Final implosion velocities in excess of 3 x 10 7 cm/sec are evident

  19. Development of real-time x-ray microtomography system

    International Nuclear Information System (INIS)

    Takano, H; Morikawa, M; Konishi, S; Azuma, H; Shimomura, S; Tsusaka, Y; Kagoshima, Y; Nakano, S; Kosaka, N; Yamamoto, K

    2013-01-01

    We have developed a four-dimensional (4D) x-ray microcomputed tomography (CT) system that can obtain time-lapse CT volumes in real time. The system consists of a high-speed sample rotation system and a high-frame-rate x-ray imager, which are installed at a synchrotron radiation x-ray beamline. As a result of system optimization and introduction of a 'zoom resolution' procedure, a real-time 4D CT movie with a frame rate of 30 was obtained with a voxel size of 2.5 μm using 10 keV x-rays

  20. Grazing Incidence X-ray Scattering and Diffraction

    Indian Academy of Sciences (India)

    IAS Admin

    several materials as a function of angle of incidence, αi with X-rays of wavelength ..... are several advantages of using this formulation for the description of surface ..... print of the surface (as shown at the botton of Figure. 5). A Soller collimator ...

  1. [X-ray diffraction experiments with condenser matter

    International Nuclear Information System (INIS)

    Coppens, P.

    1990-01-01

    This report discusses research on the following topics: high-T c superconductors; The response of crystal to an applied electric field; quasicrystals; surface structure and kinetics of surface layer formation; EXAFS studies of superconductors and heterostructures; effect of iron on the crystal structure of perovskite; x-ray detector development; and SAXS experiments

  2. Structural Investigations of Nanowires Using X-Ray Diffraction

    DEFF Research Database (Denmark)

    Stankevic, Tomas

    Advancements in growth of the nanowire-based devices opened another dimension of possible structures and material combinations, which nd their applications in a wide variety of elds, including everyday life. Characterization of such devices brings its own challenges and here we show that X-rays oer...

  3. X-ray powder diffraction in forensic practice

    Czech Academy of Sciences Publication Activity Database

    Kotrlý, M.; Bezdička, Petr

    2006-01-01

    Roč. 13, č. 3 (2006), s. 153-155 ISSN 1210-8529 R&D Projects: GA MV RN20052005001 Institutional research plan: CEZ:AV0Z40320502 Keywords : X-ray powder microdiffraction * pigments * forensic practice Subject RIV: CA - Inorganic Chemistry

  4. Refractive x-ray lens for high pressure diffraction

    International Nuclear Information System (INIS)

    Ohishi, Yasuo

    2001-01-01

    A stacked compound refractive x-ray lens was designed to produce a efficiently focused (φ 2 and a peak gain of 12, is well matched to these requirements. It is composed of many plastic chips made by molding, which is allowing many identical chips to be made precisely. Other advantages of this lens include high throughput, simple energy tunability and easy installation. (author)

  5. Time-resolved materials science opportunities using synchrotron x-ray sources

    International Nuclear Information System (INIS)

    Larson, B.C.; Tischler, J.Z.

    1995-06-01

    The high brightness, high intensity, and pulsed time-structure of synchrotron sources provide new opportunities for time-resolved x-ray diffraction investigations. With third generation synchrotron sources coming on line, high brilliance and high brightness are now available in x-ray beams with the highest flux. In addition to the high average flux, the instantaneous flux available in synchrotron beams is greatly enhanced by the pulsed time structure, which consists of short bursts of x-rays that are separated by ∼tens to hundreds of nanoseconds. Time-resolved one- and two-dimensional position sensitive detection techniques that take advantage of synchrotron radiation for materials science x-ray diffraction investigations are presented, and time resolved materials science applications are discussed in terms of recent diffraction and spectroscopy results and materials research opportunities

  6. Physical methods for studying minerals and solid materials: X-ray, electron and neutron diffraction; scanning and transmission electron microscopy; X-ray, electron and ion spectrometry

    International Nuclear Information System (INIS)

    Eberhart, J.-P.

    1976-01-01

    The following topics are discussed: theoretical aspects of radiation-matter interactions; production and measurement of radiations (X rays, electrons, neutrons); applications of radiation interactions to the study of crystalline materials. The following techniques are presented: X-ray and neutron diffraction, electron microscopy, electron diffraction, X-ray fluorescence analysis, electron probe microanalysis, surface analysis by electron emission spectrometry (ESCA and Auger electrons), scanning electron microscopy, secondary ion emission analysis [fr

  7. Measurements of transient electron density distributions by femtosecond X-ray diffraction; Messungen transienter Elektronendichteverteilungen durch Femtosekunden-Roentgenbeugung

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, Benjamin

    2013-05-02

    This thesis concerns measurements of transient charge density maps by femtosecond X-ray diffraction. Different X-ray diffraction methods will be considered, particularly with regard to their application in femtosecond X-ray diffraction. The rotation method is commonly used in stationary X-ray diffraction. In the work in hand an X-ray diffraction experiment is demonstrated, which combines the method with ultrafast X-ray pulses. This experiment is the first implementation which makes use of the rotation method to map transient intensities of a multitude of Bragg reflections. As a prototype material Bismuth is used, which previously was studied frequently by femtosecond X-ray diffraction by measuring Bragg reflections successively. The experimental results of the present work are compared with the literature data. In the second part a powder-diffraction experiment will be presented, which is used to study the dynamics of the electron-density distribution on ultrafast time scales. The experiment investigates a transition metal complex after photoexcitation of the metal to ligand charge transfer state. Besides expected results, i. e. the change of the bond length between the metal and the ligand and the transfer of electronic charge from the metal to the ligand, a strong contribution of the anion to the charge transfer was found. Furthermore, the charge transfer has predominantly a cooperative character. That is, the excitation of a single complex causes an alteration of the charge density of several neighboring units. The results show that more than 30 transition-metal complexes and 60 anions contribute to the charge transfer. This collective response is a consequence of the strong coulomb interactions of the densely packed ions.

  8. X-ray diffraction studies on single and mixed confectionery fats using synchrotron radiation

    International Nuclear Information System (INIS)

    MacMillan, S.C.; Roberts, K.J.; Wells, M.; Polgreen, M.; Smith, I.

    1999-01-01

    Full text: Understanding and refining the molecular-scale processes involved in the manufacture of structured materials such as long-chain hydrocarbon compounds is important in many commercial areas such as the petrochemical, biochemical, food, pharmaceutical and soap industries. In such processes crystallisation is an important separation, purification and preparation technique. Despite this our knowledge of the crystallisation process itself is surprisingly limited. In order to improve the crystallisation of confectionery fats, the crystallisation of it's main component, cocoa butter fat, must be properly understood. Cocoa butter fat can exhibit up to 6 polymorphic forms of different crystallographic structures with melting points varying from 17.3 deg C to 36.3 deg C. During the production of chocolate it is essential to control the polymorphic form of fats present, in order to produce a final product with the correct physical and rheological properties. Both shear rate and temperature are thought to play a crucial role in this process. The most widely used method for studying polymorphism is X-ray diffraction. Typical X-ray diffraction patterns of fats exhibit two groups of diffraction lines corresponding to the long and short spacings. The long spacings correspond to the planes formed by the methyl end groups and are dependent on the chain length and the angle of tilt of the component fatty acids of the glyceride molecules. The short spacings refer to the cross sectional packing of the hydrocarbon chain and are independent of the chain length. The relationship between crystallisation rate, polymorphic form, shear and the fat composition has for the first time been quantified, which will enable more accurate control of the polymorhic form in chocolate production. This has been achieved by developing an improved in-situ cell for X-ray studies. The X-ray studies are necessary for the examination of on-line studies under well controlled conditions of temperature

  9. X-ray diffraction studies on single and mixed confectionery fats using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    MacMillan, S.C.; Roberts, K.J.; Wells, M.; Polgreen, M.; Smith, I. [Heriot-Watt University, Edinburgh, (United Kingdom). Department of Mechanical and Chemical Engineering, Centre for Molecular and Interface Engineering

    1999-12-01

    Full text: Understanding and refining the molecular-scale processes involved in the manufacture of structured materials such as long-chain hydrocarbon compounds is important in many commercial areas such as the petrochemical, biochemical, food, pharmaceutical and soap industries. In such processes crystallisation is an important separation, purification and preparation technique. Despite this our knowledge of the crystallisation process itself is surprisingly limited. In order to improve the crystallisation of confectionery fats, the crystallisation of it`s main component, cocoa butter fat, must be properly understood. Cocoa butter fat can exhibit up to 6 polymorphic forms of different crystallographic structures with melting points varying from 17.3 deg C to 36.3 deg C. During the production of chocolate it is essential to control the polymorphic form of fats present, in order to produce a final product with the correct physical and rheological properties. Both shear rate and temperature are thought to play a crucial role in this process. The most widely used method for studying polymorphism is X-ray diffraction. Typical X-ray diffraction patterns of fats exhibit two groups of diffraction lines corresponding to the long and short spacings. The long spacings correspond to the planes formed by the methyl end groups and are dependent on the chain length and the angle of tilt of the component fatty acids of the glyceride molecules. The short spacings refer to the cross sectional packing of the hydrocarbon chain and are independent of the chain length. The relationship between crystallisation rate, polymorphic form, shear and the fat composition has for the first time been quantified, which will enable more accurate control of the polymorhic form in chocolate production. This has been achieved by developing an improved in-situ cell for X-ray studies. The X-ray studies are necessary for the examination of on-line studies under well controlled conditions of temperature

  10. Characterization of diffraction gratings by use of a tabletop soft-x-ray laser

    International Nuclear Information System (INIS)

    Seminario, Max; Rocca, Jorge J.; Depine, Ricardo A.; Bach, Benny; Bach, Bernie

    2001-01-01

    We have demonstrated the use of a high-repetition-rate 46.9-mm tabletop laser to characterize diffraction gratings designed for grazing-incidence operation in the soft-x-ray spectral region. The efficiencies for various diffraction orders were measured as a function of angle of incidence and compared with the results of model simulations. This measurement technique provides benchmarks with which to improve electromagnetic codes used in the design of soft-x-ray diffraction gratings. The results illustrate the potential of compact tabletop soft-x-ray lasers for use as a new tool for characterization of short-wavelength optics at the manufacturer's site

  11. Review - X-ray diffraction measurements in high magnetic fields and at high temperatures

    Directory of Open Access Journals (Sweden)

    Yoshifuru Mitsui, Keiichi Koyama and Kazuo Watanabe

    2009-01-01

    Full Text Available A system was developed measuring x-ray powder diffraction in high magnetic fields up to 5 T and at temperatures from 283 to 473 K. The stability of the temperature is within 1 K over 6 h. In order to examine the ability of the system, the high-field x-ray diffraction measurements were carried out for Si and a Ni-based ferromagnetic shape-memory alloy. The results show that the x-ray powder diffraction measurements in high magnetic fields and at high temperatures are useful for materials research.

  12. Electronic structure of nanoscale Cu/Pt alloys: A combined X-ray diffraction and X-ray absorption investigations

    International Nuclear Information System (INIS)

    Chen Xing; Chu Wangsheng; Cai Quan; Xia Dingguo; Wu Zhonghua; Wu Ziyu

    2006-01-01

    PVP-protected Cu/Pt clusters were prepared by glycol/water reduction method and characterized with transmission electron microscopy (TEM), X-ray diffraction (XRD) and absorption spectra. TEM and XRD analysis show that the Cu/Pt clusters with different molar ratio have fcc structure with particle size of about 4 nm, while the lattice parameters in these clusters reduce with increasing Cu concentration. From the X-ray absorption near edge structure (XANES) at Cu-K edge and Pt-L 2,3 edge, we demonstrate that the d-electronic states of Cu and Pt are affected by the local environment as a function of Cu/Pt molar ratio. With increasing Cu concentration, Pt loses a fraction of 5d electrons and the hybridization between p- and d-states at Cu sites is enhanced

  13. Electronic structure of nanoscale Cu/Pt alloys: A combined X-ray diffraction and X-ray absorption investigations

    Energy Technology Data Exchange (ETDEWEB)

    Chen Xing [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Graduate School of the Chinese Academy of Sciences, 100864 Beijing (China); Chu Wangsheng [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); University of Science and Technology of China, Hefei, 230036 (China); Cai Quan [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Graduate School of the Chinese Academy of Sciences, 100864 Beijing (China); Xia Dingguo [College of Environmental and Energy Engineering, Beijing University of Technology, 100022 Beijing (China); Wu Zhonghua [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China); Wu Ziyu [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, CAS, Beijing (China) and National Center for Nanoscience and Technology (China)]. E-mail: wuzy@ihep.ac.cn

    2006-11-15

    PVP-protected Cu/Pt clusters were prepared by glycol/water reduction method and characterized with transmission electron microscopy (TEM), X-ray diffraction (XRD) and absorption spectra. TEM and XRD analysis show that the Cu/Pt clusters with different molar ratio have fcc structure with particle size of about 4 nm, while the lattice parameters in these clusters reduce with increasing Cu concentration. From the X-ray absorption near edge structure (XANES) at Cu-K edge and Pt-L{sub 2,3} edge, we demonstrate that the d-electronic states of Cu and Pt are affected by the local environment as a function of Cu/Pt molar ratio. With increasing Cu concentration, Pt loses a fraction of 5d electrons and the hybridization between p- and d-states at Cu sites is enhanced.

  14. Degradation of periodic multilayers as seen by small-angle x-ray scattering and x-ray diffraction

    CERN Document Server

    Rafaja, D; Simek, D; Zdeborova, L; Valvoda, V

    2002-01-01

    The capabilities of small-angle x-ray scattering (SAXS) and wide-angle x-ray diffraction (XRD) to recognize structural changes in periodic multilayers were compared on Fe/Au multilayers with different degrees of structural degradation. Experimental results have shown that both methods are equally sensitive to the multilayer degradation, i.e., to the occurrence of non-continuous interfaces, to short-circuits in the multilayer structure and to the multilayer precipitation. XRD yielded additional information on the multilayer crystallinity, whilst SAXS could better recognize fragments of a long-range periodicity (remnants of the original multilayer structure). Changes in the multilayer structure were initiated by successive annealing at 200 and 300 deg. C. Experimental data were complemented by numerical simulations performed using a combination of optical theory and the distorted wave Born approximation for SAXS or the kinematical Born approximation for XRD.

  15. Peculiarities of section topograms for the multiple diffraction of X rays

    Energy Technology Data Exchange (ETDEWEB)

    Kohn, V. G., E-mail: kohnvict@yandex.ru [National Research Centre “Kurchatov Institute” (Russian Federation); Smirnova, I. A. [Russian Academy of Sciences, Institute of Solid State Physics (Russian Federation)

    2016-07-15

    The distortion of interference fringes on the section topograms of single crystal due to the multiple diffraction of X rays has been investigated. The cases of the 220 and 400 reflections in a silicon crystal in the form of a plate with a surface oriented normally to the [001] direction are considered both theoretically and experimentally. The same section topogram exhibits five cases of multiple diffraction at small azimuthal angles for the 400 reflection and MoK{sub α} radiation, while the topogram for the 220 reflection demonstrates two cases of multiple diffraction. All these cases correspond to different combinations of reciprocal lattice vectors. Exact theoretical calculations of section topograms for the aforementioned cases of multiple diffraction have been performed for the first time. The section topograms exhibit two different distortion regions. The distortions in the central region of the structure are fairly complex and depend strongly on the azimuthal angle. In the tails of the multiple diffraction region, there is a shift of two-beam interference fringes, which can be observed even with a laboratory X-ray source.

  16. X-ray diffraction studies of NbTe2 single crystal

    Indian Academy of Sciences (India)

    Unknown

    X-ray (EDAX) and remaining structural characterization was also accomplished by X-ray diffraction (XRD) studies. Lattice parameters, volume and ... The layered structure compound, NbTe2, is one of the typical materials which lead to charge .... financial assistance to carry out this work. References. Brown B E 1966 Acta ...

  17. Interaction between lipid monolayers and poloxamer 188: An X-ray reflectivity and diffraction study

    DEFF Research Database (Denmark)

    Wu, G.H.; Majewski, J.; Ege, C.

    2005-01-01

    The mechanism by which poloxamer 188 (P188) seals a damaged cell membrane is examined using the lipid monolayer as a model system. X-ray reflectivity and grazing-incidence x-ray diffraction results show that at low nominal lipid density, P188, by physically occupying the available area and phase ...

  18. Microprocessor-based system for automatic X-ray diffraction and fluorescence

    International Nuclear Information System (INIS)

    Souza, A.M. de; Carmo, L.C.S. do; Pereira, V.J.E.; Soares, E.A.

    1984-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. The Z-80 based system as well as the whole architeture is described. The advantages and new possibilities of the automated instrument as compared to the traditional ones are listed. The X-ray diffraction and fluorescence techniques can take advantage of the automation. (Author) [pt

  19. High-energy X-ray diffraction studies of disordered materials

    International Nuclear Information System (INIS)

    Kohara, Shinji; Suzuya, Kentaro

    2003-01-01

    With the arrival of the latest generation of synchrotron sources and the introduction of advanced insertion devices (wigglers and undulators), the high-energy (E≥50 keV) X-ray diffraction technique has become feasible, leading to new approaches in the quantitative study of the structure of disordered materials. High-energy X-ray diffraction has several advantages: higher resolution in real space due to a wide range of scattering vector Q, smaller correction terms (especially the absorption correction), reduction of truncation errors, the feasibility of running under extreme environments, including high-temperatures and high-pressures, and the ability to make direct comparisons between X-ray and neutron diffraction data. Recently, high-energy X-ray diffraction data have been combined with neutron diffraction data from a pulsed source to provide more detailed and reliable structural information than that hitherto available

  20. In situ X-ray diffraction studies on the piezoelectric response of PZT thin films

    Energy Technology Data Exchange (ETDEWEB)

    Davydok, A., E-mail: davydok@mpie.de [Aix Marseille Université, CNRS, Université de Toulon, IM2NP UMR 7334, 13397 Marseille (France); Max-Planck-Institut für Eisenforschung, Department Structure and Nano-/Micromechanics of Materials, D-40237 Düsseldorf (Germany); Cornelius, T.W. [Aix Marseille Université, CNRS, Université de Toulon, IM2NP UMR 7334, 13397 Marseille (France); Mocuta, C. [SOLEIL Synchrotron, DiffAbs beamline, L' Orme des Merisiers, Saint-Aubin - BP 48, 91192 Gif-sur-Yvette Cedex (France); Lima, E.C. [Universidade Federal do Tocantins, 77500-000 Porto Nacional, TO (Brazil); Araujo, E.B. [Departamento de Fisica e Quimica, Universidade Estadual Paulista, Av. Brasil, 56 Centro, 15385-000 Ilha Solteira, SP (Brazil); Thomas, O. [Aix Marseille Université, CNRS, Université de Toulon, IM2NP UMR 7334, 13397 Marseille (France)

    2016-03-31

    Piezoelectric properties of randomly oriented self-polarized PbZr{sub 0.50}Ti{sub 0.50}O{sub 3} (PZT) thin films were investigated using in situ synchrotron X-ray diffraction. Possibilities for investigating the piezoelectric effect using micro-sized hard X-ray beams are demonstrated and perspectives for future dynamical measurements on PZT samples with variety of compositions and thicknesses are given. Studies performed on the crystalline [100, 110] directions evidenced piezoelectric anisotropy. The piezoelectric coefficient d{sub 33} was calculated in terms of the lab reference frame (d{sub perp}) and found to be two times larger along the [100] direction than along the [110] direction. The absolute values for the d{sub perp} amount to 120 and 230 pm/V being in good agreement with experimental and theoretical values found in literature for bulk PZT ceramics. - Highlights: • We performed in situ synchrotron X-ray diffraction studies on (PZT) thin films. • We discuss anisotropy of piezo effect in different crystallographic directions. • Perpendicular component Piezo coefficient of thin PZT layer is defined.

  1. Investigation of electronic order using resonant soft X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Schlappa, J.

    2006-12-01

    The aim of this PhD work was the application of resonant soft X-ray diffraction technique for the investigation of electronic order in transition metal oxides at the TM L{sub 2,3}-edge, trying to obtain a quantitative understanding of the data. The method was first systematically explored through application to a model system in order to test the feasibility of the technique and to understand of how X-ray optical effects have to be taken into account. Two more complex systems were investigated; stripe order in La{sub 1.8}Sr{sub 0.2}NiO{sub 4} and charge and orbital order in Fe{sub 3}O{sub 4}. The main focus of the work was on the spectroscopic potential of the technique, trying to obtain a level of quantitative description of the data. For X-ray absorption spectroscopy (XAS) from transition metal oxides, cluster configuration interaction calculation provides a powerful and realistic microscopic theory. In the frame work of this thesis cluster theory, considering explicit hybridization effects between the TM-ion and the surrounding oxygen ligands, has been applied for the first time to describe resonant diffraction data. (orig.)

  2. Quantitative determination of minerals in Nevada Test Site samples by x-ray diffraction

    International Nuclear Information System (INIS)

    Pawloski, G.A.

    1983-07-01

    The external standard intensity ratio technique has been developed into a routine procedure for quantitatively determining mineralogic compositions of Nevada Test Site (NTS) samples by x-ray diffraction. This technique used ratios of x-ray intensity peaks from the same run which eliminates many possible errors. Constants have been determined for each of thirteen minerals commonly found in NTS samples - quartz, montmorillonite, illite, clinoptilolite, cristobalite, feldspars, calcite, dolomite, hornblende, kaolinite, muscovite, biotite, and amorphous glass. Ratios of the highest intensity peak of each mineral to be quantified in the sample and the highest intensity peak of quartz are used to calculate sample composition. The technique has been tested on samples with three to eleven components representative of geologic environments at NTS, and is accurate to 7.0 wt % of the total sample. The minimum amount of each of these minerals detectable by x-ray diffraction has also been determined. QUANTS is a computer code that calculates mineral contents and produces a report sheet. Constants for minerals in NTS samples other than those listed above can easily be determined, and added to QUANTS at any time

  3. Investigation of electronic order using resonant soft X-ray diffraction

    International Nuclear Information System (INIS)

    Schlappa, J.

    2006-01-01

    The aim of this PhD work was the application of resonant soft X-ray diffraction technique for the investigation of electronic order in transition metal oxides at the TM L 2,3 -edge, trying to obtain a quantitative understanding of the data. The method was first systematically explored through application to a model system in order to test the feasibility of the technique and to understand of how X-ray optical effects have to be taken into account. Two more complex systems were investigated; stripe order in La 1.8 Sr 0.2 NiO 4 and charge and orbital order in Fe 3 O 4 . The main focus of the work was on the spectroscopic potential of the technique, trying to obtain a level of quantitative description of the data. For X-ray absorption spectroscopy (XAS) from transition metal oxides, cluster configuration interaction calculation provides a powerful and realistic microscopic theory. In the frame work of this thesis cluster theory, considering explicit hybridization effects between the TM-ion and the surrounding oxygen ligands, has been applied for the first time to describe resonant diffraction data. (orig.)

  4. In Situ X-ray Diffraction Studies of (De)lithiation Mechanism in Silicon Nanowire Anodes

    KAUST Repository

    Misra, Sumohan

    2012-06-26

    Figure Persented: Silicon is a promising anode material for Li-ion batteries due to its high theoretical specific capacity. From previous work, silicon nanowires (SiNWs) are known to undergo amorphorization during lithiation, and no crystalline Li-Si product has been observed. In this work, we use an X-ray transparent battery cell to perform in situ synchrotron X-ray diffraction on SiNWs in real time during electrochemical cycling. At deep lithiation voltages the known metastable Li 15Si 4 phase forms, and we show that avoiding the formation of this phase, by modifying the SiNW growth temperature, improves the cycling performance of SiNW anodes. Our results provide insight on the (de)lithiation mechanism and a correlation between phase evolution and electrochemical performance for SiNW anodes. © 2012 American Chemical Society.

  5. Curved anode wire chambers for x-ray diffraction applications

    International Nuclear Information System (INIS)

    Perez-Mendez, V.; Wiedenbeck, P.; Wagner, C.N.J.; Woelfel, E.

    1983-01-01

    Curved position sensitive proportional detectors are described. The first has a radius of curvature of 135 mm and a 60 0 angular range. The second has a radius of curvature of 360 mm and a 45 0 angular range. For high quantum efficiency for x-ray energies up to 60 keV, a relatively large x-ray path and high gas pressure are required. The anode wires are suspended in circular arcs by the interaction of a current flowing through them and a magnetic field provided by two permanent magnets placed above and below the wire running parallel to it over the full length of the curved chambers. Anode wire stability under the combined action of the magnetic and electrostatic forces is discussed

  6. Preferred orientation determination using line source x-ray diffraction

    International Nuclear Information System (INIS)

    Kimmel, G.; Shmarjahu, D.

    1977-10-01

    A texture goniometer has been attached to a diffractometer connected to a line-focus x-ray source. Reasonable results are obtained for the texture of rolled sheets and the test procedure is given. To illustrate the test procedure, the determination of preferred orientation in cold-rolled copper is described, as compared with random powder of sintered copper. Improvements of the measurements are proposed

  7. Reflectivity and diffraction of X rays applied to organic thin films

    International Nuclear Information System (INIS)

    Rieutord, Francois

    1987-01-01

    This research thesis reports the study of organic thin films by using X-ray-based technologies, and more particularly X-ray reflectivity. After some recalls on X ray diffraction, and on the fabrication of Langmuir-Blodgett films, the author shows how, by combining three X-ray-based techniques, it is possible to study a volume structure of a thin film. He describes the technique of measurement by X- ray reflexivity, its experimental implementation, and methods for result interpretation. In the next part, the author reports the study of peculiar interference effects which are noticed in reflexivity on Langmuir-Blodgett films, and then describes the nature of these films by correlating results of X ray reflexivity with direct observations performed by electronic microscopy on replica [fr

  8. Time-resolved x-ray diffraction studies on the intensity changes of the 5.9 and 5.1 nm actin layer lines from frog skeletal muscle during an isometric tetanus using synchrotron radiation

    International Nuclear Information System (INIS)

    Wakabayashi, K.; Tanaka, H.; Amemiya, Y.; Fujishima, A.; Kobayashi, T.; Hamanaka, T.; Sugi, H.; Mitsui, T.

    1985-01-01

    Time-resolved x-ray diffraction studies have been made on the 5.9- and 5.1-nm actin layer lines from frog skeletal muscles during an isometric tetanus at 6 degrees C, using synchrotron radiation. The integrated intensities of these actin layer lines were found to increase during a tetanus by 30-50% for the 5.9-nm reflection and approximately 70% for the 5.1-nm reflection of the resting values. The intensity increase of both reflections was greater than that taking place in the transition from rest to rigor state. The intensity change of the 5.9-nm reflection preceded those of the myosin 42.9-nm off-meridional reflection and of the equatorial reflections, as well as the isometric tension development. The intensity profile of the 5.9-nm layer line during contraction was found to be different from that observed in the rigor state

  9. State-of-the-art and problems of X-ray diffraction analysis of biomacromolecules

    International Nuclear Information System (INIS)

    Andreeva, N. S.

    2006-01-01

    The state-of-the-art of X-ray diffraction studies of biomacromolecules is briefly characterized, and the challenge imposed by science is discussed. These studies are characterized by a wide scope and extensive use. This field of science is of great interest and is developed in many countries. The main purpose is to solve practical problems in medicine consisting in the design of drugs against various diseases. X-ray diffraction analysis of enzymes brought the pharmaceutical industry to a new level, thus allowing the rational design of drugs against formerly untreatable diseases. Modern X-ray diffraction studies of biomacromolecules laid the basis for a new science called structural biology. This method allows one to solve fundamental problems of physical chemistry for a new state of matter existing in living systems. Here, science poses numerous problems in analysis of X-ray diffraction data on biological macromolecules. Many of theses problems are in their infancy

  10. Quantitative method of X-ray diffraction phase analysis of building materials

    International Nuclear Information System (INIS)

    Czuba, J.; Dziedzic, A.

    1978-01-01

    Quantitative method of X-ray diffraction phase analysis of building materials, with use of internal standard, has been presented. The errors committed by determining the content of particular phases have been also given. (author)

  11. Scientific Challenges for a New X-ray Timing Mission

    International Nuclear Information System (INIS)

    Lamb, Frederick K.

    2004-01-01

    The Rossi X-ray Timing Explorer (RXTE) is an immensely successful mission of exploration and discovery. It has discovered a wealth of rapid X-ray variability phenomena that can be used to address fundamental questions concerning the properties of dense matter and strong gravitational fields as well as important astrophysical questions. It has answered many questions and is likely to answer many more, but to follow up fully on the major discoveries RXTE has made will require a new X-ray timing mission with greater capabilities. This introduction to the present volume describes briefly the advantages of X-ray timing measurements for determining the properties of dense matter and strong gravitational fields, indicates some of the key scientific questions that can be addressed using X-ray timing, and summarizes selected achievements of the RXTE mission. It concludes by citing some of the scientific capabilities a proposed follow-on mission will need in order to be successful

  12. Structural investigation of GaInP nanowires using X-ray diffraction

    DEFF Research Database (Denmark)

    Kriegner, D.; Persson, Johan Mikael; Etzelstorfer, T.

    2013-01-01

    In this work the structure of ternary GaxIn1−xP nanowires is investigated with respect to the chemical composition and homogeneity. The nanowires were grown by metal–organic vapor-phase epitaxy. For the investigation of ensemble fluctuations on several lateral length scales, X-ray diffraction...... gradients along the sample by recording diffraction patterns at different positions. In addition, compositional variations were found also within single nanowires in X-ray energy dispersive spectroscopy measurements....

  13. Study of the solid solution formation in mixed oxides by X-ray diffraction

    International Nuclear Information System (INIS)

    Riella, H.G.

    1984-01-01

    A method to determine the plutonium distribution in mixed oxides - UO 2 /PuO 2 is described. The distribution function and the medium size of crystallite are obtained from the X-ray diffraction profile. Through the deconvolution by Fourier analysis, the X-ray diffraction profile is obtained without the influence of the difractrometer. Some experimental results for different samples of UO 2 -PuO 2 discussed. (Author) [pt

  14. On the evaluation of X-ray diffraction experiments by the regularization method

    Energy Technology Data Exchange (ETDEWEB)

    Trubin, V.A.; Szasz, A. (Lab. of Surface and Interface Physics, Eoetvoes Univ., Budapest (Hungary))

    1991-05-16

    The characteristic property of diffractometers as the presence of occasional and systematic errors in measured patterns requires such an evaluation which is as informative as possible. This circumstance gives rise to the problem of optimal planning of the experiment. The X-ray diffraction optimization problem with application of the regularization method is studied. The proposal permits to determine more accurately the unknown true characteristics of the X-ray diffraction experiment. (orig.).

  15. On the evaluation of X-ray diffraction experiments by the regularization method

    International Nuclear Information System (INIS)

    Trubin, V.A.; Szasz, A.

    1991-01-01

    The characteristic property of diffractometers as the presence of occasional and systematic errors in measured patterns requires such an evaluation which is as informative as possible. This circumstance gives rise to the problem of optimal planning of the experiment. The X-ray diffraction optimization problem with application of the regularization method is studied. The proposal permits to determine more accurately the unknown true characteristics of the X-ray diffraction experiment. (orig.)

  16. Time-resolved X-ray studies using third generation synchrotron radiation sources

    International Nuclear Information System (INIS)

    Mills, D.M.

    1991-10-01

    The third generation, high-brilliance, hard x-ray, synchrotron radiation (SR) sources currently under construction (ESRF at Grenoble, France; APS at Argonne, Illinois; and SPring-8 at Harima, Japan) will usher in a new era of x-ray experimentation for both physical and biological sciences. One of the most exciting areas of experimentation will be the extension of x-ray scattering and diffraction techniques to the study of transient or time-evolving systems. The high repetition rate, short-pulse duration, high brilliance, and variable spectral bandwidth of these sources make them ideal for x-ray time-resolved studies. The temporal properties (bunch length, interpulse period, etc.) of these new sources will be summarized. Finally, the scientific potential and the technological challenges of time-resolved x-ray scattering from these new sources will be described. 13 refs., 4 figs

  17. A portable X-ray diffraction apparatus for in situ analyses of masters' paintings

    International Nuclear Information System (INIS)

    Eveno, Myriam; Duran, Adrian; Castaing, Jacques

    2010-01-01

    It is rare that the analyses of materials in paintings can be carried out by taking micro-samples. Valuable works of art are best studied in situ by non-invasive techniques. For that purpose, a portable X-ray diffraction and fluorescence apparatus has been designed and constructed at the C2RMF. This apparatus has been used for paintings of Rembrandt, Leonardo da Vinci, Van Gogh, Mantegna, etc. Results are given to illustrate the performance of X-ray diffraction, especially when X-ray fluorescence does not bring sufficient information to conclude. (orig.)

  18. A portable X-ray diffraction apparatus for in situ analyses of masters' paintings

    Science.gov (United States)

    Eveno, Myriam; Duran, Adrian; Castaing, Jacques

    2010-09-01

    It is rare that the analyses of materials in paintings can be carried out by taking micro-samples. Valuable works of art are best studied in situ by non-invasive techniques. For that purpose, a portable X-ray diffraction and fluorescence apparatus has been designed and constructed at the C2RMF. This apparatus has been used for paintings of Rembrandt, Leonardo da Vinci, Van Gogh, Mantegna, etc. Results are given to illustrate the performance of X-ray diffraction, especially when X-ray fluorescence does not bring sufficient information to conclude.

  19. Device for high-temperature X-ray diffraction analysis. Ustrojstvo dlya vysokotemperaturnogo rentgenostrukturnogo analiza

    Energy Technology Data Exchange (ETDEWEB)

    Epifanov, V G; Zavilinskij, A V; Pet' kov, V V; Polenur, A V

    1975-01-07

    Device for high-temperature X-ray diffraction analysis, containing a vacuum chamber with a window for X-ray transit, in which sample- and standard-holders, heater, thermal shields and means for standard and sample temperature measurement are located, is proposed. In order to increase the working temperature level and the structural change detection accuracy the heater is located between the sample- and standard-holders. The standard-holder is linked with the mechanism of control of its position in relation to the heater. The device is intended for investigating phase transformations by differential thermal analysis method with the simultaneous diffraction pattern detection using X-ray diffractometry method.

  20. Neutron and X-ray diffraction from modulated structures

    International Nuclear Information System (INIS)

    Harris, P.

    1994-07-01

    This thesis describes X-ray and neutron scattering experiments performed on two examples of modulated structures. After an introduction to the subject of modulated structures, the thesis is divided in three parts. A single crystal elastic neutron scattering experiment between 4.2 and 115 Κ has been performed and four-circle X-ray data have been collected at 8 Κ for the monoclinic low-temperature phase of the layered perovskite PAMC. The results from the neutron scattering experiment indicate that magnetoelastic effects influence the ordering of the crystal. The X-ray experiments have made it possible to determine the crystal structure in the low-temperature phase. The superspace group is P2 1 /b(β-30)Os, with β = 1/3. A small-angle neutron scattering experiment has been performed on the magnetic structure of manganese silicide. When a magnetic field is applied, the modulation vectors turn towards the field direction, showing domain growth and diverging peak widths as they approach the field direction. Phase 'A' is established to have the modulation vectors directed perpendicular to the field direction. Cooling in zero field shows increasing peak widths at low temperatures, indicating a lock-in transition below the lowest reached temperature. To be able to analyse the data of the magnetic order in MnSi, and analytical calculation of the three dimensional resolution function for a small-angle neutron scattering spectrometer has been performed. The calculation is done by application of a combination of phase space analysis and Gaussian approximations for the neutron distribution as well as for the transmission functions of the different apertures. A finite mosaic spread of the crystal and finite correlation widths of the Bragg reflections have been included in the cross section. (au) (3 tabs., 48 ills., 100 refs.)

  1. Preparation and characterization of gold nanocrystals and nanomultilayer mirrors for X-ray diffraction experiments

    International Nuclear Information System (INIS)

    Slieh, Jawad

    2009-03-01

    In order to make possible studies on the dynamics of protein molecules in their natural environment Sasaki has developed in the last years a new X-ray diffraction procedure. In this procedure, which is called dynamical X-ray tracking (DXT), the diffraction occurs not directly on the protein molecule, but on a nanomirror rigidly bound to the protein molecule. Measured is hereby the time variation od the alignment of the nanocrystal, which is determined by means of the position of the Laue-diffraction points. By means of these position variations statements on structure variations of the studied protein can be derived with a high spatial accuracy in the time domain. The scientific aim of this thesis is the construction of a DXT measuring place as well as the preparation of the requireds nanocrystalline X-ray diffracting protein labels including their characterization. First a short survey about the foundations of the X radiation and their interactions with matter, especially under regardment of X-ray diffraction on crystals, is given. The measuring methods for the determination of the crystal alignment as well as the vertical and lateral crystal size are presented. In the following chapter a comprehensive survey about the different devices and analysis methods used for the fabrication and characterization of gold crystals is presented. Additionally with precise technical statements the self-constructed MBE apparature is described. This apparature has the purpose to fabricate gold nanocrystals by means of the molecular-beam-epitaxy (MBE) procedure. In the fourth chapter the construction of the DXT laboratory are presented and its beam profile in the focus, its divergence, and its beam spectrum determined. Based on this in the fifth chapter the study of the radiation damage of 2 cysteine-peroxyredoxine (2CP) proteins and the detection of this radiation damage without Au colloids and with Au colloids are presented. The main content of the sixth chapter is the precise

  2. X-ray diffraction study of surface-layer structure in parallel grazing rays

    International Nuclear Information System (INIS)

    Shtypulyak, N.I.; Yakimov, I.I.; Litvintsev, V.V.

    1989-01-01

    An x-ray diffraction method is described for study of thin polycrystalline and amorphous films and surface layers in an extremely asymmetrical diffraction system in parallel grazing rays using a DRON-3.0 diffractometer. The minimum grazing angles correspond to diffraction under conditions of total external reflection and a layer depth of ∼ 2.5-8 nm

  3. X-ray and Neutron Diffraction in the Study of Organic Crystalline Hydrates

    Directory of Open Access Journals (Sweden)

    Katharina Fucke

    2010-07-01

    Full Text Available A review. Diffraction methods are a powerful tool to investigate the crystal structure of organic compounds in general and their hydrates in particular. The laboratory standard technique of single crystal X-ray diffraction gives information about the molecular conformation, packing and hydrogen bonding in the crystal structure, while powder X-ray diffraction on bulk material can trace hydration/dehydration processes and phase transitions under non-ambient conditions. Neutron diffraction is a valuable complementary technique to X-ray diffraction and gives highly accurate hydrogen atom positions due to the interaction of the radiation with the atomic nuclei. Although not yet often applied to organic hydrates, neutron single crystal and neutron powder diffraction give precise structural data on hydrogen bonding networks which will help explain why hydrates form in the first place.

  4. Background removal in X-ray fiber diffraction patterns

    International Nuclear Information System (INIS)

    Millane, R.P.; Arnott, S.

    1985-01-01

    Background can be a major source of error in measurement of diffracted intensities in fiber diffraction patterns. Errors can be large when poorly oriented less-crystalline specimens give diffraction patterns with little uncontaminated background. A method for estimating and removing a general global background in such cases is described and illustrated with an example. (orig.)

  5. In-situ X-ray diffraction system using sources and detectors at fixed angular positions

    Science.gov (United States)

    Gibson, David M [Voorheesville, NY; Gibson, Walter M [Voorheesville, NY; Huang, Huapeng [Latham, NY

    2007-06-26

    An x-ray diffraction technique for measuring a known characteristic of a sample of a material in an in-situ state. The technique includes using an x-ray source for emitting substantially divergent x-ray radiation--with a collimating optic disposed with respect to the fixed source for producing a substantially parallel beam of x-ray radiation by receiving and redirecting the divergent paths of the divergent x-ray radiation. A first x-ray detector collects radiation diffracted from the sample; wherein the source and detector are fixed, during operation thereof, in position relative to each other and in at least one dimension relative to the sample according to a-priori knowledge about the known characteristic of the sample. A second x-ray detector may be fixed relative to the first x-ray detector according to the a-priori knowledge about the known characteristic of the sample, especially in a phase monitoring embodiment of the present invention.

  6. [Study of selegiline and related compounds with x-ray diffraction].

    Science.gov (United States)

    Simon, K; Böcskei, Z; Török, Z

    1992-09-01

    Selegiline and its parent compounds were studied by X-ray diffraction. It was established that the racemates of primary and secondary amines (p-fluoro-amphetamine, methamphetamine, p-fluoro-methamphetamine) hydrochloride do not form racemic compounds but crystalline as conglomerates, at the same time tertiary amines like selegiline and p-fluoro-selegiline hydrochlorides do. The crystalline structure of five enantiomeric hydrochlorides were determined, the CPhe-C-C-N torsion angle is anti-periplanar in all cases but in p-fluoro-amphetamine where it is gauche.

  7. Final Report for X-ray Diffraction Sample Preparation Method Development

    Energy Technology Data Exchange (ETDEWEB)

    Ely, T. M. [Hanford Site (HNF), Richland, WA (United States); Meznarich, H. K. [Hanford Site (HNF), Richland, WA (United States); Valero, T. [Hanford Site (HNF), Richland, WA (United States)

    2018-01-30

    WRPS-1500790, “X-ray Diffraction Saltcake Sample Preparation Method Development Plan/Procedure,” was originally prepared with the intent of improving the specimen preparation methodology used to generate saltcake specimens suitable for XRD-based solid phase characterization. At the time that this test plan document was originally developed, packed powder in cavity supports with collodion binder was the established XRD specimen preparation method. An alternate specimen preparation method less vulnerable, if not completely invulnerable to preferred orientation effects, was desired as a replacement for the method.

  8. Characteristics of a molybdenum X-pinch X-ray source as a probe source for X-ray diffraction studies

    International Nuclear Information System (INIS)

    Zucchini, F.; Chauvin, C.; Combes, P.; Sol, D.; Loyen, A.; Roques, B.; Grunenwald, J.; Bland, S. N.

    2015-01-01

    X-ray emission from a molybdenum X-pinch has been investigated as a potential probe for the high pressure states made in dynamic compression experiments. Studies were performed on a novel 300 kA, 400 ns generator which coupled the load directly to a low inductance capacitor and switch combination. The X-pinch load consisted of 4 crossed molybdenum wires of 13 μm diameter, crossed at an angle of 62°. The load height was 10 mm. An initial x-ray burst generated at the wire crossing point, radiated in the soft x-ray range (hυ < 10 keV). This was followed, 2–5 ns later, by at least one harder x-ray burst (hυ > 10 keV) whose power ranged from 1 to 7 MW. Time integrated spectral measurements showed that the harder bursts were dominated by K-alpha emission; though, a lower level, wide band continuum up to at least 30 keV was also present. Initial tests demonstrated that the source was capable of driving Laue diffraction experiments, probing uncompressed samples of LiF and aluminium

  9. In Situ High Resolution Synchrotron X-Ray Powder Diffraction Studies of Lithium Batteries

    DEFF Research Database (Denmark)

    Amri, Mahrez; Fitch, Andy; Norby, Poul

    2015-01-01

    allowing diffraction information to be obtained from only the active material during battery operation [2]. High resolution synchrotron x-ray powder diffraction technique has been undertaken to obtain detailed structural and compositional information during lithiation/delithiation of commercial LiFePO4...... materials [3]. We report results from the first in situ time resolved high resolution powder diffraction experiments at beamline ID22/31 at the European Synchrotron Radiation Facility, ESRF. We follow the structural changes during charge of commercial LiFePO4 based battery materials using the Rietveld...... method. Conscientious Rietveld analysis shows slight but continuous deviation of lattice parameters from those of the fully stoichiometric end members LiFePO4 and FePO4 indicating a subsequent variation of stoichiometry during cathode delithiation. The application of an intermittent current pulses during...

  10. Evaluation of In-Vacuum Imaging Plate Detector for X-Ray Diffraction Microscopy

    International Nuclear Information System (INIS)

    Nishino, Yoshinori; Takahashi, Yukio; Yamamoto, Masaki; Ishikawa, Tetsuya

    2007-01-01

    We performed evaluation tests of a newly developed in-vacuum imaging plate (IP) detector for x-ray diffraction microscopy. IP detectors have advantages over direct x-ray detection charge-coupled device (CCD) detectors, which have been commonly used in x-ray diffraction microscopy experiments, in the capabilities for a high photon count and for a wide area. The detector system contains two IPs to make measurement efficient by recording data with the one while reading or erasing the other. We compared speckled diffraction patterns of single particles taken with the IP and a direct x-ray detection CCD. The IP was inferior to the CCD in spatial resolution and in signal-to-noise ratio at a low photon count

  11. A Pipelining Implementation for Parsing X-ray Diffraction Source Data and Removing the Background Noise

    International Nuclear Information System (INIS)

    Bauer, Michael A; Biem, Alain; McIntyre, Stewart; Xie Yuzhen

    2010-01-01

    Synchrotrons can be used to generate X-rays in order to probe materials at the atomic level. One approach is to use X-ray diffraction (XRD) to do this. The data from an XRD experiment consists of a sequence of digital image files which for a single scan could consist of hundreds or even thousands of digital images. Existing analysis software processes these images individually sequentially and is usually used after the experiment is completed. The results from an XRD detector can be thought of as a sequence of images, generated during the scan by the X-ray beam. If these images could be analyzed in near real-time, the results could be sent to the researcher running the experiment and used to improve the overall experimental process and results. In this paper, we report on a stream processing application to remove background from XRD images using a pipelining implementation. We describe our implementation techniques of using IBM Infosphere Streams for parsing XRD source data and removing the background. We present experimental results showing the super-linear speedup attained over a purely sequential version of the algorithm on a quad-core machine. These results demonstrate the potential of making good use of multi-cores for high-performance stream processing of XRD images.

  12. Integrating macromolecular X-ray diffraction data with the graphical user interface iMosflm.

    Science.gov (United States)

    Powell, Harold R; Battye, T Geoff G; Kontogiannis, Luke; Johnson, Owen; Leslie, Andrew G W

    2017-07-01

    X-ray crystallography is the predominant source of structural information for biological macromolecules, providing fundamental insights into biological function. The availability of robust and user-friendly software to process the collected X-ray diffraction images makes the technique accessible to a wider range of scientists. iMosflm/MOSFLM (http://www.mrc-lmb.cam.ac.uk/harry/imosflm) is a software package designed to achieve this goal. The graphical user interface (GUI) version of MOSFLM (called iMosflm) is designed to guide inexperienced users through the steps of data integration, while retaining powerful features for more experienced users. Images from almost all commercially available X-ray detectors can be handled using this software. Although the program uses only 2D profile fitting, it can readily integrate data collected in the 'fine phi-slicing' mode (in which the rotation angle per image is less than the crystal mosaic spread by a factor of at least 2), which is commonly used with modern very fast readout detectors. The GUI provides real-time feedback on the success of the indexing step and the progress of data processing. This feedback includes the ability to monitor detector and crystal parameter refinement and to display the average spot shape in different regions of the detector. Data scaling and merging tasks can be initiated directly from the interface. Using this protocol, a data set of 360 images with ∼2,000 reflections per image can be processed in ∼4 min.

  13. Energy dispersive X-ray diffraction as a means to identify illicit materials: A preliminary optimisation study

    Energy Technology Data Exchange (ETDEWEB)

    Cook, Emily [Department of Medical Physics and Bioengineering, UCL, London WC1E 6BT (United Kingdom)]. E-mail: ecook@medphys.ucl.ac.uk; Fong, Ruby [Clinical Physics Department, St Bartholomew' s Hospital, London EC1A 7BE (United Kingdom); Horrocks, Julie [Clinical Physics Department, St Bartholomew' s Hospital, London EC1A 7BE (United Kingdom); Wilkinson, David [HOSDB, Woodcock Hill, Sandridge, Herts. AL4 9HQ (United Kingdom); Speller, Robert [Department of Medical Physics and Bioengineering, UCL, London WC1E 6BT (United Kingdom)

    2007-08-15

    Energy dispersive X-ray diffraction is proposed as a suitable non-destructive method to rapidly identify illicit drugs in parcels. A preliminary data set of 7 illicit drug samples and a possible cutting agent has been collected with a range of count times using a tungsten target X-ray source, a high resolution HpGe detector and a variable geometry diffraction cell. These results have been used to calibrate and train multivariate analysis software to predict the drug content in previously unseen spectra.

  14. Energy dispersive X-ray diffraction as a means to identify illicit materials: A preliminary optimisation study

    International Nuclear Information System (INIS)

    Cook, Emily; Fong, Ruby; Horrocks, Julie; Wilkinson, David; Speller, Robert

    2007-01-01

    Energy dispersive X-ray diffraction is proposed as a suitable non-destructive method to rapidly identify illicit drugs in parcels. A preliminary data set of 7 illicit drug samples and a possible cutting agent has been collected with a range of count times using a tungsten target X-ray source, a high resolution HpGe detector and a variable geometry diffraction cell. These results have been used to calibrate and train multivariate analysis software to predict the drug content in previously unseen spectra

  15. Advanced x-ray stress analysis method for a single crystal using different diffraction plane families

    International Nuclear Information System (INIS)

    Imafuku, Muneyuki; Suzuki, Hiroshi; Sueyoshi, Kazuyuki; Akita, Koichi; Ohya, Shin-ichi

    2008-01-01

    Generalized formula of the x-ray stress analysis for a single crystal with unknown stress-free lattice parameter was proposed. This method enables us to evaluate the plane stress states with any combination of diffraction planes. We can choose and combine the appropriate x-ray sources and diffraction plane families, depending on the sample orientation and the apparatus, whenever diffraction condition is satisfied. The analysis of plane stress distributions in an iron single crystal was demonstrated combining with the diffraction data for Fe{211} and Fe{310} plane families

  16. The reflected amplitude ratio of multilayers and superlattice describe the dynamical diffraction of x-rays

    International Nuclear Information System (INIS)

    Bhatti, Q.A.; Mangi, F.A.

    2006-01-01

    Calculating the rocking curves of complicated layered structures, such as non-ideal super lattices on perfect crystals are clearly exposed with observed diffraction profile. Recursion formulas for calculating reflected amplitude ratio of multilayer and super lattices have been involved from the Takagi-Taupin differential equation, which describes the dynamical diffraction of X-rays in deformed crystal. The Kinematical theory can computing time only in case of ideal superlattice for which geometric series can be used but the reflectivity must be below 10 % so that multiple reflections can be neglected for a perfect crystal of arbitrary thickness the absorption at the centre of the dynamical reflection is found to be proportional to the square root of the reflectivity. Sputter- deposited periodic multilayers of tungsten and carbon can be considered as an artificial crystal, for which dynamical X-rays diffraction calculations give the result very similar to those of macroscopic optical description in terms of the complex index of refraction and Frensnel relation coefficient. (author)

  17. Comparison of dissimilarity measures for cluster analysis of X-ray diffraction data from combinatorial libraries

    Science.gov (United States)

    Iwasaki, Yuma; Kusne, A. Gilad; Takeuchi, Ichiro

    2017-12-01

    Machine learning techniques have proven invaluable to manage the ever growing volume of materials research data produced as developments continue in high-throughput materials simulation, fabrication, and characterization. In particular, machine learning techniques have been demonstrated for their utility in rapidly and automatically identifying potential composition-phase maps from structural data characterization of composition spread libraries, enabling rapid materials fabrication-structure-property analysis and functional materials discovery. A key issue in development of an automated phase-diagram determination method is the choice of dissimilarity measure, or kernel function. The desired measure reduces the impact of confounding structural data issues on analysis performance. The issues include peak height changes and peak shifting due to lattice constant change as a function of composition. In this work, we investigate the choice of dissimilarity measure in X-ray diffraction-based structure analysis and the choice of measure's performance impact on automatic composition-phase map determination. Nine dissimilarity measures are investigated for their impact in analyzing X-ray diffraction patterns for a Fe-Co-Ni ternary alloy composition spread. The cosine, Pearson correlation coefficient, and Jensen-Shannon divergence measures are shown to provide the best performance in the presence of peak height change and peak shifting (due to lattice constant change) when the magnitude of peak shifting is unknown. With prior knowledge of the maximum peak shifting, dynamic time warping in a normalized constrained mode provides the best performance. This work also serves to demonstrate a strategy for rapid analysis of a large number of X-ray diffraction patterns in general beyond data from combinatorial libraries.

  18. Applications of synchrotron x-ray diffraction topography to fractography

    International Nuclear Information System (INIS)

    Bilello, J.C.

    1983-01-01

    Fractographs have been taken using a variety of probes each of which produces different types of information. Methods which have been used to examine fracture surfaces include: (a) optical microscopy, particularly interference contrast methods, (b) scanning electron microscopy (SEM), (c) SEM with electron channelling, (d) SEM with selected-area electron channelling, (e) Berg-Barrett (B-B) topography, and now (f) synchrotron x-radiation fractography (SXRF). This review concentrated on the role that x-ray methods can play in such studies. In particular, the ability to nondestructively assess the subsurface microstructure associated with the fracture to depths of the order of 5 to 10 μm becomes an important attribute for observations of a large class of semi-brittle metals, semiconductors and ceramics

  19. Time switch for X-ray diagnosis apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Distler, G; Goetzl, H

    1977-04-07

    A time switch for dental X-rays consists of a knob to select exposure time. Two scales are concentrically mounted, one for time, and one with the various tooth symbols, in such a way that the various teeth are in correspondence with the usually recommended times. However, should the X-ray tube characteristics vary at some stage, by pressing the knob, then turning, the 'tooth scale' can be rotated for setting the exposure times at higher or lower levels.

  20. Combining X-ray Absorption and X-ray Diffraction Techniques for in Situ Studies of Chemical Transformations in Heterogeneous Catalysis: Advantages and Limitations

    International Nuclear Information System (INIS)

    Frenkel, A.I.; Hanson, J.; Wang, Q.; Marinkovic, N.; Chen, J.G.; Barrio, L.; Si, R.; Lopez Camara, A.; Estrella, A.M.; Rodriguez, J.A.

    2011-01-01

    Recent advances in catalysis instrumentations include synchrotron-based facilities where time-resolved X-ray scattering and absorption techniques are combined in the same in situ or operando experiment to study catalysts at work. To evaluate the advances and limitations of this method, we performed a series of experiments at the new XAFS/XRD instrument in the National Synchrotron Light Source. Nearly simultaneous X-ray diffraction (XRD) and X-ray absorption fine-structure (XAFS) measurements of structure and kinetics of several catalysts under reducing or oxidizing conditions have been performed and carefully analyzed. For CuFe 2 O 4 under reducing conditions, the combined use of the two techniques allowed us to obtain accurate data on kinetics of nucleation and growth of metallic Cu. For the inverse catalyst CuO/CeO 2 that underwent isothermal reduction (with CO) and oxidation (with O 2 ), the XAFS data measured in the same experiment with XRD revealed strongly disordered Cu species that went undetected by diffraction. These and other examples emphasize the unique sensitivity of these two complementary methods to follow catalytic processes in the broad ranges of length and time scales.

  1. X-ray and neutron diffraction studies of crystallinity in hydroxyapatite coatings.

    Science.gov (United States)

    Girardin, E; Millet, P; Lodini, A

    2000-02-01

    To standardize industrial implant production and make comparisons between different experimental results, we have to be able to quantify the crystallinity of hydroxyapatite. Methods of measuring crystallinity ratio were developed for various HA samples before and after plasma spraying. The first series of methods uses X-ray diffraction. The advantage of these methods is that X-ray diffraction equipment is used widely in science and industry. In the second series, a neutron diffraction method is developed and the results recorded are similar to those obtained by the modified X-ray diffraction methods. The advantage of neutron diffraction is the ability to obtain measurements deep inside a component. It is a nondestructive method, owing to the very low absorption of neutrons in most materials. Copyright 2000 John Wiley & Sons, Inc.

  2. High Pressure X-Ray Diffraction Studies on Nanocrystalline Materials

    Science.gov (United States)

    Palosz, B.; Stelmakh, S.; Grzanka, E.; Gierlotka, S.; Pielaszek, R.; Bismayer, U.; Werner, S.; Palosz, W.

    2003-01-01

    Application of in situ high pressure powder diffraction technique for examination of specific structural properties of nanocrystals based on the experimental data of SiC nanocrystalline powders of 2 to 30 nrn diameter in diameter is presented. Limitations and capabilities of the experimental techniques themselves and methods of diffraction data elaboration applied to nanocrystals with very small dimensions (nanoparticles of different grain size.

  3. Measurement of grain size of polycrystalline materials with confocal energy dispersive micro-X-ray diffraction technology based on polycapillary X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Weiyuan; Liu, Zhiguo [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Sun, Tianxi, E-mail: stx@bnu.edu.cn [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Peng, Song [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China); Ma, Yongzhong [Center for Disease Control and Prevention of Beijing, Beijing 100013 (China); Li, Fangzuo; Sun, Xuepeng; Ding, Xunliang [The Key Laboratory of Beam Technology and Materials Modification of the Ministry of Education, Beijing Normal University, Beijing 100875 (China); College of Nuclear Science and Technology, Beijing Normal University, Beijing 100875 (China); Beijing Radiation Center, Beijing 100875 (China)

    2014-11-11

    The confocal energy dispersive micro-X-ray diffraction (EDMXRD) based on polycapillary X-ray optics was used to determine the grain size of polycrystalline materials. The grain size of a metallographic specimen of nickel base alloy was measured by using the confocal EDMXRD. The experimental results demonstrated that the confocal EDMXRD had potential applications in measuring large grain size.

  4. Comparative study of macrotexture analysis using X-ray diffraction and electron backscattered diffraction techniques

    International Nuclear Information System (INIS)

    Serna, Marilene Morelli

    2002-01-01

    The macrotexture is one of the main characteristics in metallic materials, which the physical properties depend on the crystallographic direction. The analysis of the macrotexture to middles of the decade of 80 was just accomplished by the techniques of Xray diffraction and neutrons diffraction. The possibility of the analysis of the macrotexture using, the technique of electron backscattering diffraction in the scanning electronic microscope, that allowed to correlate the measure of the orientation with its location in the micro structure, was a very welcome tool in the area of engineering of materials. In this work it was studied the theoretical aspects of the two techniques and it was used of both techniques for the analysis of the macrotexture of aluminum sheets 1050 and 3003 with intensity, measured through the texture index 'J', from 2.00 to 5.00. The results obtained by the two techniques were shown reasonably similar, being considered that the statistics of the data obtained by the technique of electron backscatter diffraction is much inferior to the obtained by the X-ray diffraction. (author)

  5. X-ray radiation damage of organic semiconductor thin films during grazing incidence diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Neuhold, A., E-mail: alfred.neuhold@tugraz.at [Institute of Solid State Physics, Graz University of Technology, Graz (Austria); Novak, J.; Flesch, H.-G.; Moser, A.; Djuric, T. [Institute of Solid State Physics, Graz University of Technology, Graz (Austria); Grodd, L.; Grigorian, S.; Pietsch, U. [Institute of Physics, University Siegen (Germany); Resel, R. [Institute of Solid State Physics, Graz University of Technology, Graz (Austria)

    2012-08-01

    Since modern synchrotrons with highly intense X-ray beams are in use to investigate organic materials, the stability of soft matter materials during beam exposure is a crucial issue. Grazing incidence X-ray diffraction and specular X-ray reflectivity measurements were performed on thin films of organic semiconducting materials, like poly(3-hexylthiophene) (P3HT), sexithiophene and pentacene. These films were irradiated with an average flux density between 10{sup 15} and 10{sup 16} photons/(s mm{sup 2}) and evidenced a different stability in synchrotron X-ray radiation. The semi-crystalline P3HT showed a clear intensity decrease of the 1 0 0 Bragg peak and 0 2 0 Bragg peak compared to the rather stable diffraction features of the molecular crystals sexithiophene and pentacene. The difference in synchrotron X-ray radiation stability is explained by the interaction of the X-ray beam with the individual chemical components in the molecules as well as by the different crystallinities of the materials. Furthermore, the semi-crystalline P3HT film exhibited an increase of film thickness after irradiation and the surface roughness slightly decreased. To summarize, this study shows a strong influence of synchrotron X-ray radiation to specific organic thin films like e.g. P3HT, while others like pentacene and sexithiophene are observed as quite stable.

  6. Microbeam high-resolution diffraction and x-ray standing wave methods applied to semiconductor structures

    International Nuclear Information System (INIS)

    Kazimirov, A; Bilderback, D H; Huang, R; Sirenko, A; Ougazzaden, A

    2004-01-01

    A new approach to conditioning x-ray microbeams for high angular resolution x-ray diffraction and scattering techniques is introduced. We combined focusing optics (one-bounce imaging capillary) and post-focusing collimating optics (miniature Si(004) channel-cut crystal) to generate an x-ray microbeam with a size of 10 μm and ultimate angular resolution of 14 μrad. The microbeam was used to analyse the strain in sub-micron thick InGaAsP epitaxial layers grown on an InP(100) substrate by the selective area growth technique in narrow openings between the oxide stripes. For the structures for which the diffraction peaks from the substrate and the film overlap, the x-ray standing wave technique was applied for precise measurements of the strain with a Δd/d resolution of better than 10 -4 . (rapid communication)

  7. New tubes and techniques for flash X-ray diffraction and high contrast radiography

    International Nuclear Information System (INIS)

    Charbonnier, F.M.; Barbour, J.P.; Brewster, J.L.

    High energy electrons are particularly efficient in producing characteristic X-rays and soft polychromatic. A line of wide spectrum beryllium window flash X-ray tubes, ranging from 150 to 600kV, has been developed to exploit this property. Laue and Debye Scherrer flash X-ray diffraction patterns have been obtained using a single 30 ns pulse exposure. X-ray diffraction tests obtained are shown. Extremely high contrast flash radiography of small, low density objects has been obtained using industrial film without screen. Alternatively, particularly at high voltages and for subjects which include a broad range of materials and thicknesses, special film techniques can be used to produce extremely wide latitudes. Equipment, techniques and results are discussed

  8. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1982-01-01

    A method of producing visible difference images derived from an x-ray image of an anatomical subject is described. X-rays are directed through the subject, and the image is converted into television fields comprising trains of analog video signals. The analog signals are converted into digital signals, which are then integrated over a predetermined time corresponding to several television fields. Difference video signals are produced by performing a subtraction between the ongoing video signals and the corresponding integrated signals, and are converted into visible television difference images representing changes in the x-ray image

  9. Information extracting and processing with diffraction enhanced imaging of X-ray

    International Nuclear Information System (INIS)

    Chen Bo; Chinese Academy of Science, Beijing; Chen Chunchong; Jiang Fan; Chen Jie; Ming Hai; Shu Hang; Zhu Peiping; Wang Junyue; Yuan Qingxi; Wu Ziyu

    2006-01-01

    X-ray imaging at high energies has been used for many years in many fields. Conventional X-ray imaging is based on the different absorption within a sample. It is difficult to distinguish different tissues of a biological sample because of their small difference in absorption. The authors use the diffraction enhanced imaging (DEI) method. The authors took images of absorption, extinction, scattering and refractivity. In the end, the authors presented pictures of high resolution with all these information combined. (authors)

  10. Dynamical x-ray diffraction studies of interfacial strain in superlattices grown by molecular beam epitaxy

    International Nuclear Information System (INIS)

    Vandenberg, J.M.; Chu, S.N.G.; Hamm, R.A.; Panish, M.B.; Ritter, D.; Mancrander, A.T.

    1992-01-01

    This paper reports on dynamical X-ray diffraction studies that have been carried out for lattice-matched InGaAs/InP superlattices grown by modified molecular beam epitaxy (MBE) techniques. The (400) X-ray satellite pattern, which is predominantly affected by the strain modulation, was analyzed. The strain and thickness of the actual layers including the presence of strained interfacial regions were determined

  11. Model experiment of in vivo synchrotron X-ray diffraction of human kidney stones

    Energy Technology Data Exchange (ETDEWEB)

    Ancharov, A.I. [Institute of Solid State Chemistry and Mechanochemistry SB RAS, Novosibirsk (Russian Federation)]. E-mail: ancharov@mail.ru; Potapov, S.S. [Institute of Mineralogy UB RAS, Miass (Russian Federation); Moiseenko, T.N. [The State Regional Clinical Hospital, Novosibirsk (Russian Federation); Feofilov, I.V. [The State Regional Clinical Hospital, Novosibirsk (Russian Federation); Nizovskii, A.I. [Boreskov Institute of Catalysis SB RAS, Novosibirsk (Russian Federation)

    2007-05-21

    The diffraction of synchrotron radiation (SR) was used to explore the phase composition of kidney stones placed into a specific object phantom, which imitated the human body. As an imitation of the patient breath, the kidney stone was moved vertically and rotated to an angle of 15{sup o} during the recording of the X-ray pattern. It was shown that rotation and displacement did not distort the X-ray pattern.

  12. Model experiment of in vivo synchrotron X-ray diffraction of human kidney stones

    International Nuclear Information System (INIS)

    Ancharov, A.I.; Potapov, S.S.; Moiseenko, T.N.; Feofilov, I.V.; Nizovskii, A.I.

    2007-01-01

    The diffraction of synchrotron radiation (SR) was used to explore the phase composition of kidney stones placed into a specific object phantom, which imitated the human body. As an imitation of the patient breath, the kidney stone was moved vertically and rotated to an angle of 15 o during the recording of the X-ray pattern. It was shown that rotation and displacement did not distort the X-ray pattern

  13. Diffractive-refractive optics: (+,-,-,+) X-ray crystal monochromator with harmonics separation

    Czech Academy of Sciences Publication Activity Database

    Hrdý, Jaromír; Mikulík, P.; Oberta, Peter

    2011-01-01

    Roč. 18, č. 2 (2011), s. 299-301 ISSN 0909-0495 R&D Projects: GA MPO FR-TI1/412 Institutional research plan: CEZ:AV0Z10100522 Keywords : diffractive-refractive optics * x-ray synchrotron radiation monochromator * x-ray crystal monochromator * harmonics separation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.726, year: 2011

  14. Nano-fabrication of diffractive optics for soft X-ray and atom beam focusing

    International Nuclear Information System (INIS)

    Rehbein, S.

    2002-01-01

    Nano-structuring processes are described for manufacturing diffractive optics for the condenser-monochromator set-up of the transmission X-ray microscope (TXM) and for the scanning transmission X-ray microscope (STXM) at the BESSY II electron storage ring in Berlin. Furthermore, a process for manufacturing free-standing nickel zone plates for helium atom beam focusing experiments is presented. (author)

  15. The discovery of X-ray diffraction by crystals and its great impact on science

    International Nuclear Information System (INIS)

    Mai Zhenhong

    2012-01-01

    In April 1912, Friedrich, Knipping and Laue discovered X-ray diffraction in a CuSO 4 crystal. Later, Laue derived the famous Laue equations which explain the diffraction phenomenon. For this, Laue was awarded a Nobel Prize for Physics in 1914. In 1912 W. H. Bragg and W. L. Bragg received news of Laue 's discovery, and from X-ray diffraction experiments in a ZnS crystal they derived the famous Bragg equation. For this work, father and son were together awarded the Nobel Prize for Physics in 1915, To commemorate the 100th anniversary of the discovery of X-ray diffraction, this article reviews the important contributions of the early pioneers and their historic impact on science and technology worldwide. (author)

  16. Materials identification using a small-scale pixellated x-ray diffraction system

    International Nuclear Information System (INIS)

    O’Flynn, D; Crews, C; Drakos, I; Christodoulou, C; Speller, R D; Wilson, M D; Veale, M C; Seller, P

    2016-01-01

    A transmission x-ray diffraction system has been developed using a pixellated, energy-resolving detector (HEXITEC) and a small-scale, mains operated x-ray source (Amptek Mini-X). HEXITEC enables diffraction to be measured without the requirement of incident spectrum filtration, or collimation of the scatter from the sample, preserving a large proportion of the useful signal compared with other diffraction techniques. Due to this efficiency, sufficient molecular information for material identification can be obtained within 5 s despite the relatively low x-ray source power. Diffraction data are presented from caffeine, hexamine, paracetamol, plastic explosives and narcotics. The capability to determine molecular information from aspirin tablets inside their packaging is demonstrated. Material selectivity and the potential for a sample classification model is shown with principal component analysis, through which each different material can be clearly resolved. (paper)

  17. Size effect in X-ray and electron diffraction patterns from hydroxyapatite particles

    International Nuclear Information System (INIS)

    Suvorova, E.I.; Buffat, P.-A.

    2001-01-01

    High-resolution transmission electron microscopy (HRTEM), electron microdiffraction, and X-ray diffraction were used to study hydroxyapatite specimens with particle sizes from a few nanometers to several hundreds of nanometers. Diffuse scattering (without clear reflections in transmission diffraction patterns) or strongly broadened peaks in X-ray diffraction patterns are characteristic for agglomerated hydroxyapatite nanocrystals. However, HRTEM and microdiffraction showed that this cannot be considered as an indication of the amorphous state of the matter but rather as the demonstration of size effect and the morphological and structural features of hydroxyapatite nanocrystals

  18. Mechanical characterisation of surface layers by x-ray diffraction -application to tribology

    International Nuclear Information System (INIS)

    Farrahi, G.H.

    1996-01-01

    The results presented in this paper show that X-ray diffraction can be employed for the characterisation of surface layer damage through residual stresses and work hardening by some tribological actions such as fretting and dry sliding. X-ray diffraction technique can also be employed for a rapid and non-destructive measurement of hardness of hardened steel. The diffraction profile analysis can offer a good indication about the materials characteristics and the microstructural evolution caused by heat treatment or by mechanical loading

  19. Energy-dispersive X-ray diffraction beamline at Indus-2 synchrotron ...

    Indian Academy of Sciences (India)

    An energy-dispersive X-ray diffraction beamline has been designed, developed and commissioned at BL-11 bending magnet port of the Indian synchrotron source, Indus-2. The performance of this beamline has been benchmarked by measuring diffraction patterns from various elemental metals and standard inorganic ...

  20. In-situ X-ray diffraction : a useful tool to investigate hydride-formation reactions

    NARCIS (Netherlands)

    Notten, P.H.L.; Daams, J.L.C.; Veirman, de A.E.M.; Staals, A.A.

    1994-01-01

    A high-pressure X-ray diffraction (XRD) cell has been designed which allowed us to study simultaneously hydrogen absorption/desorption isotherms and XRD powder diffraction patterns on (de)hydrided intermetallic compounds. The hydride formation reaction was investigated in the case of LaNi5 under

  1. Small angle X ray diffraction investigation of twinned opal_like structures

    NARCIS (Netherlands)

    Samusev, A.K.; Sinev, I.S.; Samusev, K.B.; Rybin, M.V.; Mistonov, A.A.; Grigoryeva, N.A.; Grigoriev, S.V.; Petukhov, A.V.; Byelov, D.; Trofimova, E.Y.; Kurdyukov, D.A.; Golubev, V.G.; Limonov, M.F.

    2012-01-01

    Small angle X ray diffraction from synthetic opal films has been investigated as a function of the orientation of the sample. All the observed (hkl) diffraction reflections have been interpreted. The reconstruct tion of the reciprocal lattice of the studied opal films has been carried out. The

  2. Analytic theory of soft x-ray diffraction by lamellar multilayer gratings

    NARCIS (Netherlands)

    Kozhevnikov, I.V.; van der Meer, R.; Bastiaens, Hubertus M.J.; Boller, Klaus J.; Bijkerk, Frederik

    2011-01-01

    An analytic theory describing soft x-ray diffraction by Lamellar Multilayer Gratings (LMG) has been developed. The theory is derived from a coupled waves approach for LMGs operating in the single-order regime, where an incident plane wave can only excite a single diffraction order. The results from

  3. X-ray diffraction investigation of the sulphur induced 4x1 reconstruction of Ni(110)

    DEFF Research Database (Denmark)

    Foss, M.; Feidenhans'l, R.; Nielsen, M.

    1993-01-01

    The atomic structure of the Ni(110)4 x 1-S reconstruction has been determined on the basis of surface X-ray diffraction measurements. An analysis of the in-plane diffraction data shows that the model consists of Ni rows along the [001] direction, two for every 4 x 1 unit cell, corresponding to 0....

  4. Grain orientation mapping of passivated aluminum interconnect wires with X-ray micro-diffraction

    International Nuclear Information System (INIS)

    MacDowell, A.A.; Padmore, H.A.; Thompson, A.C.; Chang, C.H.; Patel, J.R.

    1998-06-01

    A micro x-ray diffraction facility is under development at the Advanced Light source. Spot sizes are typically about 1-microm size generated by means of grazing incidence Kirkpatrick-Baez focusing mirrors. Photon energy is either white of energy range 6--14 keV or monochromatic generated from a pair of channel cut crystals. A Laue diffraction pattern from a single grain in passivated 2-microm wide bamboo structured Aluminum interconnect line has been recorded. Acquisition times are of the order of a few seconds. The Laue pattern has allowed the determination of the crystallographic orientation of individual grains along the line length. The experimental and analysis procedures used are described, as is a grain orientation result. The future direction of this program is discussed in the context of strain measurements in the area of electromigration

  5. Liquid contrabands classification based on energy dispersive X-ray diffraction and hybrid discriminant analysis

    International Nuclear Information System (INIS)

    YangDai, Tianyi; Zhang, Li

    2016-01-01

    Energy dispersive X-ray diffraction (EDXRD) combined with hybrid discriminant analysis (HDA) has been utilized for classifying the liquid materials for the first time. The XRD spectra of 37 kinds of liquid contrabands and daily supplies were obtained using an EDXRD test bed facility. The unique spectra of different samples reveal XRD's capability to distinguish liquid contrabands from daily supplies. In order to create a system to detect liquid contrabands, the diffraction spectra were subjected to HDA which is the combination of principal components analysis (PCA) and linear discriminant analysis (LDA). Experiments based on the leave-one-out method demonstrate that HDA is a practical method with higher classification accuracy and lower noise sensitivity than the other methods in this application. The study shows the great capability and potential of the combination of XRD and HDA for liquid contrabands classification.

  6. Liquid contrabands classification based on energy dispersive X-ray diffraction and hybrid discriminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    YangDai, Tianyi [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Zhang, Li, E-mail: zhangli@nuctech.com [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China)

    2016-02-01

    Energy dispersive X-ray diffraction (EDXRD) combined with hybrid discriminant analysis (HDA) has been utilized for classifying the liquid materials for the first time. The XRD spectra of 37 kinds of liquid contrabands and daily supplies were obtained using an EDXRD test bed facility. The unique spectra of different samples reveal XRD's capability to distinguish liquid contrabands from daily supplies. In order to create a system to detect liquid contrabands, the diffraction spectra were subjected to HDA which is the combination of principal components analysis (PCA) and linear discriminant analysis (LDA). Experiments based on the leave-one-out method demonstrate that HDA is a practical method with higher classification accuracy and lower noise sensitivity than the other methods in this application. The study shows the great capability and potential of the combination of XRD and HDA for liquid contrabands classification.

  7. Liquid contrabands classification based on energy dispersive X-ray diffraction and hybrid discriminant analysis

    Science.gov (United States)

    YangDai, Tianyi; Zhang, Li

    2016-02-01

    Energy dispersive X-ray diffraction (EDXRD) combined with hybrid discriminant analysis (HDA) has been utilized for classifying the liquid materials for the first time. The XRD spectra of 37 kinds of liquid contrabands and daily supplies were obtained using an EDXRD test bed facility. The unique spectra of different samples reveal XRD's capability to distinguish liquid contrabands from daily supplies. In order to create a system to detect liquid contrabands, the diffraction spectra were subjected to HDA which is the combination of principal components analysis (PCA) and linear discriminant analysis (LDA). Experiments based on the leave-one-out method demonstrate that HDA is a practical method with higher classification accuracy and lower noise sensitivity than the other methods in this application. The study shows the great capability and potential of the combination of XRD and HDA for liquid contrabands classification.

  8. Soft X-ray Foucault test: A path to diffraction-limited imaging

    Science.gov (United States)

    Ray-Chaudhuri, A. K.; Ng, W.; Liang, S.; Cerrina, F.

    1994-08-01

    We present the development of a soft X-ray Foucault test capable of characterizing the imaging properties of a soft X-ray optical system at its operational wavelength and its operational configuration. This optical test enables direct visual inspection of imaging aberrations and provides real-time feedback for the alignment of high resolution soft X-ray optical systems. A first application of this optical test was carried out on a Mo-Si multilayer-coated Schwarzschild objective as part of the MAXIMUM project. Results from the alignment procedure are presented as well as the possibility for testing in the hard X-ray regime.

  9. New structural studies of liquid crystal by reflectivity and resonant X-ray diffraction

    International Nuclear Information System (INIS)

    Fernandes, P.

    2007-04-01

    This memory presents three structural studies of smectic Liquid Crystals by reflectivity and resonant diffraction of X-rays. It is divided in five chapters. In the first a short introduction to Liquid Crystals is given. In particular, the smectic phases that are the object of this study are presented. The second chapter is consecrated to the X-ray experimental techniques that were used in this work. The three last chapters present the works on which this thesis can be divided. Chapter three demonstrates on free-standing films of MHPOBC (historic liquid crystal that possesses the antiferroelectric sub-phases) the possibility to extend the technique of resonant X-ray diffraction to liquid crystals without resonant element. In the fourth chapter the structure of the B 2 liquid crystal phase of bent-core molecules (or banana molecules) is elucidated by using resonant X-ray diffraction combined with polarization analysis of the diffracted beam. A model of the polarization of the resonant beam diffracted by four different structures proposed for the B 2 phase is developed in this chapter. In the fifth chapter a smectic binary mixture presenting a very original critical point of phase separation is studied by X-ray reflectivity and optical microscopy. A concentration gradient in the direction perpendicular to the plane of the film seems to be induced by the free-standing film geometry. The results of a simplified model of the system are compatible with this interpretation

  10. An x-ray detector for time-resolved studies

    International Nuclear Information System (INIS)

    Rodricks, B.; Brizard, C.; Clarke, R.; Lowe, W.

    1992-01-01

    The development of ultrahigh-brightness x-ray sources makes time-resolved x-ray studies more and more feasible. Improvements in x-ray optics components are also critical for obtaining the appropriate beam for a particular type of experiment. Moreover, fast parallel detectors will be essential in order to exploit the combination of high intensity x-ray sources and novel optics for time-resolved experiments. A CCD detector with a time resolution of microseconds has been developed at the Advanced Photon Source (APS). This detector is fully programmable using CAMAC electronics and a Micro Vax computer. The techniques of time-resolved x-ray studies, which include scattering, microradiography, microtomography, stroboscopy, etc., can be applied to a range of phenomena (including rapid thermal annealing, surface ordering, crystallization, and the kinetics of phase transition) in order to understand these time-dependent microscopic processes. Some of these applications will be illustrated by recent results performed at synchrotrons. New powerful x-ray sources now under construction offer the opportunity to apply innovative approaches in time-resolved work

  11. Takagi-Taupin description of x-ray dynamical diffraction from diffractive optics with large numerical aperture

    International Nuclear Information System (INIS)

    Yan Hanfei; Maser, Joerg; Macrander, Albert; Shen Qun; Vogt, Stefan; Stephenson, G. Brian; Kang, Hyon Chol

    2007-01-01

    We present a formalism of x-ray dynamical diffraction from volume diffractive optics with large numerical aperture and high aspect ratio, in an analogy to the Takagi-Taupin equations [Acta Crystallogr. 15, 1311 (1962); Bull. Soc. Fr. Mineral. Crystallogr. 87, 469 (1964)] for strained single crystals. We derive a set of basic equations for dynamical diffraction from volume diffractive optics, which enable us to study the focusing property of these optics with various grating profiles. We study volume diffractive optics that satisfy the Bragg condition to various degrees, namely, flat, tilted, and wedged geometries, and derive the curved geometries required for ultimate focusing. We show that the curved geometries satisfy both the Bragg condition everywhere and phase requirement for point focusing and effectively focus hard x rays to a scale close to the wavelength. Our calculations were made for an x-ray wavelength of 0.064 nm (19.5 keV)

  12. Phase quantification in nanobainite via magnetic measurements and X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Solano-Alvarez, W., E-mail: ws298@cam.ac.uk [Department of Materials Science and Metallurgy, University of Cambridge (United Kingdom); Abreu, H.F.G. [Departamento de Engenharia Metalúrgica e de Materiais, Universidade Federal do Ceará, Fortaleza (Brazil); Silva, M.R. da [Instituto de Física e Química, Universidade Federal de Itajubá, Itajubá, Minas Gerais (Brazil); Peet, M.J. [Department of Materials Science and Metallurgy, University of Cambridge (United Kingdom)

    2015-03-15

    Accurate phase quantification of nanostructured bainitic steel is of importance because of the nature of its percolating structure that controls many of its mechanical properties. X-ray diffraction is the technique of choice for such analysis, but magnetic methods can be more rapid and less sensitive to defect structures. In this study, the phase volume fractions measured using both of these techniques for the specific mixtures associated with nanostructured bainite have been compared and contrasted. An expression which relates the volume fraction and the saturation magnetization is obtained and its form is found to be consistent with previous work done on duplex stainless steels and TRIP steels. The fitting constants used in many of such analyses vary significantly so an attempt is made to rationalize the differences by considering the factors that determine the intrinsic saturation magnetization of ferrite. - Author-Highlights: • Magnetic phase quantification of nanobainite is presented for the first time. • Results are compared with x-ray diffraction. • Expression obtained that relates ferrite fraction and saturation magnetization. • Equation derived to calculate intrinsic saturation magnetization of ferrites. • These values agree with experimental data of the literature.

  13. Study of gold nanoparticle synthesis by synchrotron x-ray diffraction and fluorescence

    Science.gov (United States)

    Yan, Zhongying; Wang, Xiao; Yu, Le; Moeendarbari, Sina; Hao, Yaowu; Cai, Zhonghou; Cheng, Xuemei

    Gold nanoparticles have a wide range of potential applications, including therapeutic agent delivery, catalysis, and electronics. Recently a new process of hollow nanoparticle synthesis was reported, the mechanism of which was hypothesized to involve electroless deposition around electrochemically evolved hydrogen bubbles. However, the growth mechanism still needs experimental evidence. We report investigation of this synthesis process using synchrotron x-ray diffraction and fluorescence measurements performed at beamline 2-ID-D of the Advanced Photon Source (APS). A series of gold nanoparticle samples with different synthesis time (50-1200 seconds) were deposited using a mixture electrolyte solution of Na3Au(SO3)2 and H4N2NiO6S2 on anodic aluminum oxide (AAO) membranes. The 2D mapping of fluorescence intensity and comparison of x-ray diffraction peaks of the samples have provided valuable information on the growth mechanism. Work at Bryn Mawr College and University of Texas at Arlington is supported by NSF Grants (1207085 and 1207377) and use of the APS at Argonne National Laboratory is supported by the U. S. Department of Energy under Contract No. DE-AC02-06CH11357.

  14. X-ray diffraction and X-ray K absorption near edge studies of copper (II) complexes with amino acids

    Science.gov (United States)

    Sharma, P. K.; Mishra, Ashutosh; Malviya, Varsha; Kame, Rashmi; Malviya, P. K.

    2017-05-01

    Synthesis of copper (II) complexes [CuL1L2X].nH2O, where n=1, 2,3 (X=Cl,Br,NO3) (L1is 2,2’-bipyridine and L2 is L-tyrosine) by the chemical root method. The XRD data for the samples have been recorded. EXAFS spectra have also been recorded at the K-edge of Cu using the dispersive beam line BL-8 at 2.5 Gev Indus-2 Synchrotron radiation source at RRCAT, Indore, India. XRD and EXAFS data have been analysed using the computer software. X-ray diffraction studies of all complexes indicate their crystalline nature. Lattice parameter, bond length, particle size have been determined from XRD data.

  15. Comparison of a CCD and an APS for soft X-ray diffraction

    International Nuclear Information System (INIS)

    Stewart, Graeme; Bates, R; Blue, A; Maneuski, D; Clark, A; Turchetta, R; Dhesi, S S; Marchal, J; Steadman, P; Tartoni, N

    2011-01-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  16. Comparison of a CCD and an APS for soft X-ray diffraction

    Science.gov (United States)

    Stewart, Graeme; Bates, R.; Blue, A.; Clark, A.; Dhesi, S. S.; Maneuski, D.; Marchal, J.; Steadman, P.; Tartoni, N.; Turchetta, R.

    2011-12-01

    We compare a new CMOS Active Pixel Sensor (APS) to a Princeton Instruments PIXIS-XO: 2048B Charge Coupled Device (CCD) with soft X-rays tested in a synchrotron beam line at the Diamond Light Source (DLS). Despite CCDs being established in the field of scientific imaging, APS are an innovative technology that offers advantages over CCDs. These include faster readout, higher operational temperature, in-pixel electronics for advanced image processing and reduced manufacturing cost. The APS employed was the Vanilla sensor designed by the MI3 collaboration and funded by an RCUK Basic technology grant. This sensor has 520 x 520 square pixels, of size 25 μm on each side. The sensor can operate at a full frame readout of up to 20 Hz. The sensor had been back-thinned, to the epitaxial layer. This was the first time that a back-thinned APS had been demonstrated at a beam line at DLS. In the synchrotron experiment soft X-rays with an energy of approximately 708 eV were used to produce a diffraction pattern from a permalloy sample. The pattern was imaged at a range of integration times with both sensors. The CCD had to be operated at a temperature of -55°C whereas the Vanilla was operated over a temperature range from 20°C to -10°C. We show that the APS detector can operate with frame rates up to two hundred times faster than the CCD, without excessive degradation of image quality. The signal to noise of the APS is shown to be the same as that of the CCD at identical integration times and the response is shown to be linear, with no charge blooming effects. The experiment has allowed a direct comparison of back thinned APS and CCDs in a real soft x-ray synchrotron experiment.

  17. Real-time digital X-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1979-01-01

    A diagnostic anatomical X-ray apparatus comprising a converter and a television camera for converting an X-ray image of a subject into a series of television fields of video signals is described in detail. A digital memory system stores and integrates the video signals over a time interval corresponding to a plurality of successive television fields. The integrated video signals are recovered from storage and fed to a digital or analogue subtractor, the resulting output being displayed on a television monitor. Thus the display represents on-going changes in the anatomical X-ray image. In a modification, successive groups of fields are stored and integrated in three memories, cyclically, and subtractions are performed between successive pieces of integrated signals to provide a display of successive alterations in the X-ray image. For investigations of the heart, the integrating interval should be of the order of one cardiac cycle. (author)

  18. X-ray Excited Optical Fluorescence and Diffraction Imaging of Reactivity and Crystallinity in a Zeolite Crystal : Crystallography and Molecular Spectroscopy in One

    NARCIS (Netherlands)

    Ristanovic, Zoran; Hofmann, Jan P; Richard, Marie-Ingrid; Jiang, Tao; Chahine, Gilbert A; Schülli, Tobias U; Meirer, Florian; Weckhuysen, Bert M

    2016-01-01

    Structure-activity relationships in heterogeneous catalysis are challenging to be measured on a single-particle level. For the first time, one X-ray beam is used to determine the crystallographic structure and reactivity of a single zeolite crystal. The method generates μm-resolved X-ray diffraction

  19. Data processing software suite SITENNO for coherent X-ray diffraction imaging using the X-ray free-electron laser SACLA

    International Nuclear Information System (INIS)

    Sekiguchi, Yuki; Oroguchi, Tomotaka; Takayama, Yuki; Nakasako, Masayoshi

    2014-01-01

    The software suite SITENNO is developed for processing diffraction data collected in coherent X-ray diffraction imaging experiments of non-crystalline particles using an X-ray free-electron laser. Coherent X-ray diffraction imaging is a promising technique for visualizing the structures of non-crystalline particles with dimensions of micrometers to sub-micrometers. Recently, X-ray free-electron laser sources have enabled efficient experiments in the ‘diffraction before destruction’ scheme. Diffraction experiments have been conducted at SPring-8 Angstrom Compact free-electron LAser (SACLA) using the custom-made diffraction apparatus KOTOBUKI-1 and two multiport CCD detectors. In the experiments, ten thousands of single-shot diffraction patterns can be collected within several hours. Then, diffraction patterns with significant levels of intensity suitable for structural analysis must be found, direct-beam positions in diffraction patterns determined, diffraction patterns from the two CCD detectors merged, and phase-retrieval calculations for structural analyses performed. A software suite named SITENNO has been developed to semi-automatically apply the four-step processing to a huge number of diffraction data. Here, details of the algorithm used in the suite are described and the performance for approximately 9000 diffraction patterns collected from cuboid-shaped copper oxide particles reported. Using the SITENNO suite, it is possible to conduct experiments with data processing immediately after the data collection, and to characterize the size distribution and internal structures of the non-crystalline particles

  20. Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method

    International Nuclear Information System (INIS)

    Dilmanian, F.A.; Ren, B.; Wu, X.Y.; Orion, I.; Zhong, Z.; Thomlinson, W.C.; Chapman, L.D.

    2000-01-01

    Diffraction enhanced imaging (DEI) is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector. The analyser allows the detection of only those x-rays transmitted by the subject that fall into the acceptance angle (central part of the rocking curve) of the monochromator/analyser system. As shown by Chapman et al , in addition to the x-ray attenuation, the method provides information on the out-of-plane angular deviation of x-rays. New images result in which the image contrast depends on the x-ray index of refraction and on the yield of small-angle scattering, respectively. We implemented DEI in the tomography mode at the National Synchrotron Light Source using 22 keV x-rays, and imaged a cylindrical acrylic phantom that included oil-filled, slanted channels. The resulting 'refraction CT image' shows the pure image of the out-of-plane gradient of the x-ray index of refraction. No image artefacts were present, indicating that the CT projection data were a consistent set. The 'refraction CT image' signal is linear with the gradient of the refractive index, and its value is equal to that expected. The method, at the energy used or higher, has the potential for use in clinical radiography and in industry. (author)

  1. Growth of ω inclusions in Ti alloys: An X-ray diffraction study

    International Nuclear Information System (INIS)

    Šmilauerová, J.; Harcuba, P.; Pospíšil, J.; Matěj, Z.; Holý, V.

    2013-01-01

    We investigated the size and crystal structure of nanometer-sized ω inclusions in single crystals of β-Ti alloys by X-ray diffraction pole-figure measurements and reciprocal space mapping. We studied the topotactical relation of the β and ω crystal lattices, and from the positions and shapes of the diffraction maxima of the ω lattice determined the mean size of the ω inclusions and the misfit of the inclusion lattice with respect to the host lattice, as well as their changes during ageing. The lattice of the ω inclusions exhibits a large positive misfit already before ageing and the misfit is subsequently reduced during the ageing process. Using the theories of elasticity and X-ray scattering we simulated diffuse X-ray scattering around the β diffraction maxima and demonstrated that the diffuse scattering is caused mainly by local elastic strains in the β host phase around the ω inclusions

  2. Determination of the strain hardening rate of metals and alloys by X ray diffraction

    International Nuclear Information System (INIS)

    Cadalbert, Robert

    1977-01-01

    This report for engineering graduation is based on the study of X ray diffraction line profile which varies with the plastic strain rate of the metal. After some generalities of strain hardening (consequence of a plastic deformation on the structure of a polycrystalline metal, means to study a strain hardened structure, use of X ray diffraction to analyse the strain hardened crystalline structure), the author reports the strain hardening rate measurement by using X ray diffraction. Several aspects are addressed: principles, experimental technique, apparatus, automation and programming of the measurement cycle, method sensitivity and precision. In the next part, the author reports applications: measurement of the strain hardening rate in different materials (tubes with hexagonal profile, cylindrical tubes in austenitic steel), and study of the evolution of strain hardening with temperature [fr

  3. Synchrotron X-ray diffraction analysis for quantitative defect evaluation in GaP/Si nanolayers

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen Thanh, T.; Robert, C. [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France); Létoublon, A., E-mail: Antoine.letoublon@insa-rennes.fr [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France); Cornet, C. [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France); Quinci, T. [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France); CEA LCP, INES, 50 av. du Lac Léman, Savoie Technolac, 73375 Le Bourget du Lac (France); Giudicelli, E.; Almosni, S. [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France); Boudet, N. [CRG-D2AM, ESRF and Inst. Néel, CNRS-UJF, 25 Av des Martyrs, 38042 Grenoble (France); Ponchet, A. [CEMES, CNRS, Université de Toulouse, 29 rue J. Marvig BP 94347, 31055 Toulouse Cedex 4 (France); Kuyyalil, J. [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France); Danila, M. [National Institute for Research and Development in Microtechnologies (IMT), 126A Erou Iancu Nicolae Street, 077190, Bucharest (Romania); Durand, O.; Bertru, N.; Le Corre, A. [Université Européenne de Bretagne, INSA, FOTON, UMR 6082, F-35708 RENNES (France)

    2013-08-31

    In the context of III–V monolithic integration on silicon, synchrotron X-ray diffraction has been employed in this study using a bi-dimensional large area hybrid pixel detector (XPAD third generation) to characterize defects in the GaP layers. Despite a very coherent interface (low plastic relaxation) of GaP/Si, 2 types of defect are detected. Micro-twins contributions are evidenced and quantitatively evaluated from additional reflections analysis. Antiphase domains are evidenced using the Williamson-Hall-like plot method applied to transverse scans extracted directly from single XPAD images taken on specular GaP reflections. - Highlights: ► Antiphase domain evidence and characterization in GaP/Si using X-ray diffraction ► Microtwin evidence and characterization ► Synchrotron diffraction ► Large area X-ray hybrid pixel detector.

  4. Submicron x-ray diffraction and its applications to problems in materials and environmental science

    Science.gov (United States)

    Tamura, N.; Celestre, R. S.; MacDowell, A. A.; Padmore, H. A.; Spolenak, R.; Valek, B. C.; Meier Chang, N.; Manceau, A.; Patel, J. R.

    2002-03-01

    The availability of high brilliance third generation synchrotron sources together with progress in achromatic focusing optics allows us to add submicron spatial resolution to the conventional century-old x-ray diffraction technique. The new capabilities include the possibility to map in situ, grain orientations, crystalline phase distribution, and full strain/stress tensors at a very local level, by combining white and monochromatic x-ray microbeam diffraction. This is particularly relevant for high technology industry where the understanding of material properties at a microstructural level becomes increasingly important. After describing the latest advances in the submicron x-ray diffraction techniques at the Advanced Light Source, we will give some examples of its application in material science for the measurement of strain/stress in metallic thin films and interconnects. Its use in the field of environmental science will also be discussed.

  5. Submicron X-Ray Diffraction and its Applications to Problems in Materials and Environmental Science

    Energy Technology Data Exchange (ETDEWEB)

    Patel, J. R.

    2002-08-16

    The availability of high brilliance 3rd generation synchrotron sources together with progress in achromatic focusing optics allow to add submicron spatial resolution to the conventional century-old X-ray diffraction technique. The new capabilities include the possibility to map in-situ, grain orientations, crystalline phase distribution and full strain/stress tensors at a very local level, by combining white and monochromatic X-ray microbeam diffraction. This is particularly relevant for high technology industry where the understanding of material properties at a microstructural level becomes increasingly important. After describing the latest advances in the submicron X-ray diffraction techniques at the ALS, we will give some examples of its application in material science for the measurement of strain/stress in metallic thin films and interconnects. Its use in the field of environmental science will also be discussed.

  6. Submicron X-ray diffraction and its applications to problems in materials and environmental science

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, N.; Celestre, R.S.; MacDowell, A.A.; Padmore, H.A.; Spolenak, R.; Valek, B.C.; Meier Chang, N.; Manceau, A.; Patel, J.R.

    2002-03-26

    The availability of high brilliance 3rd generation synchrotron sources together with progress in achromatic focusing optics allow to add submicron spatial resolution to the conventional century-old X-ray diffraction technique. The new capabilities include the possibility to map in-situ, grain orientations, crystalline phase distribution and full strain/stress tensors at a very local level, by combining white and monochromatic X-ray microbeam diffraction. This is particularly relevant for high technology industry where the understanding of material properties at a microstructural level becomes increasingly important. After describing the latest advances in the submicron X-ray diffraction techniques at the ALS, we will give some examples of its application in material science for the measurement of strain/stress in metallic thin films and interconnects. Its use in the field of environmental science will also be discussed.

  7. Thin film growth studies using time-resolved x-ray scattering

    Science.gov (United States)

    Kowarik, Stefan

    2017-02-01

    Thin-film growth is important for novel functional materials and new generations of devices. The non-equilibrium growth physics involved is very challenging, because the energy landscape for atomic scale processes is determined by many parameters, such as the diffusion and Ehrlich-Schwoebel barriers. We review the in situ real-time techniques of x-ray diffraction (XRD), x-ray growth oscillations and diffuse x-ray scattering (GISAXS) for the determination of structure and morphology on length scales from Å to µm. We give examples of time resolved growth experiments mainly from molecular thin film growth, but also highlight growth of inorganic materials using molecular beam epitaxy (MBE) and electrochemical deposition from liquids. We discuss how scaling parameters of rate equation models and fundamental energy barriers in kinetic Monte Carlo methods can be determined from fits of the real-time x-ray data.

  8. Instrumentation of x-ray diffraction and materials research on the National Synchrotron Light Source. Final report

    International Nuclear Information System (INIS)

    Liedl, G.L.

    1984-11-01

    MATRIX was organized in 1980 to formulate a research team to design and construct a beam line at NSLS for x-ray diffraction studies of materials. A versatile system was designed to allow a full range of experimental capabilities for wide angle x-ray scattering experiments including surface diffraction studies. The design and construction of the system has been completed. Testing of parts of the system was completed at CHESS and with x-ray sources or other equipment at member institutions. Installation of the beam line at NSLS is in progress and will proceed in parallel with the commissioning of the x-ray ring at NSLS. Full operation of the beam line is expected to be ready by December 1, 1984 being limited only by the source power of NSLS at that time. Useful experiments could be started if the power is at least 2 GeV and 100ma. The MATRIX beam line was one of the first x-ray beam lines to see light in the beam line in early spring of 1984. In July of 1984, the MATRIX beam line as the first port at NSLS to have a monochromatic beam and to scan part of the spectrum from the source. As part of this contract, six publications have resulted from the various projects. Three publications are concerned directly with the beam line and/or its operation while the other three publications are the result of research associated with the project

  9. X-ray diffraction patterns of metal aurocyanides

    International Nuclear Information System (INIS)

    Selig, W.S.; Smith, G.S.; Harding, K.K.; Summers, L.J.

    1989-06-01

    Aurocyanides of the following metal cations have been prepared: Ag, Hg(II), Ga, Fe(III), Tl(I), Bi, Pb, Mn(II), Ni, Zn, Cu(II), Cd, In, and Co(II). Most of the aurocyanides are of the type M[Au(CN) 2 ] x where M is the metal cation and x its valence. However, under some conditions mixed aurocyanides containing K may be formed, such as KCo[Au(CN) 2 ] 3 . Only Ag and Hg(II) form aurocyanides which are sufficiently insoluble for the potentiometric determination of the aurocyanide anion. The diffraction patterns of the various aurocyanides are reported. 12 refs., 16 tabs

  10. X-ray diffraction microscopy based on refractive optics

    DEFF Research Database (Denmark)

    Poulsen, Henning Friis; Jakobsen, A. C.; Simons, Hugh

    2017-01-01

    A formalism is presented for dark‐field X‐ray microscopy using refractive optics. The new technique can produce three‐dimensional maps of lattice orientation and axial strain within millimetre‐sized sampling volumes and is particularly suited to in situ studies of materials at hard X‐ray energies....... An objective lens in the diffracted beam magnifies the image and acts as a very efficient filter in reciprocal space, enabling the imaging of individual domains of interest with a resolution of 100 nm. Analytical expressions for optical parameters such as numerical aperture, vignetting, and the resolution...

  11. X-ray grazing incidence diffraction from multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Tixier, S.; Boeni, P.; Swygenhoven, H. van; Horisberger, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Grazing incidence scattering geometries using synchrotron radiation have been applied in order to characterise the roughness profiles and the structural coherence of multilayers. The lateral correlation length of the roughness profiles was evaluated using diffuse reflectivity in the `out of plane` geometry. This type of measurement is the only diffuse reflectivity technique allowing large lateral momentum transfer. It is typically suitable for correlation lengths smaller than 1000 A. The lateral structural coherence length of Ni{sub 3}Al/Ni multilayers as a function of the layer thickness was obtained by grazing incidence diffraction (GID). 3 figs., 1 ref.

  12. Coherent x-ray diffraction imaging of paint pigment particles by scanning a phase plate modulator

    International Nuclear Information System (INIS)

    Chu, Y.S.; Chen, B.; Zhang, F.; Berenguer, F.; Bean, R.; Kewish, C.; Vila-Comamala, J.; Rodenburg, J.; Robinson, I.

    2011-01-01

    We have implemented a coherent x-ray diffraction imaging technique that scans a phase plate to modulate wave-fronts of the x-ray beam transmitted by samples. The method was applied to measure a decorative alkyd paint containing iron oxide red pigment particles. By employing an iterative algorithm for wave-front modulation phase retrieval, we obtained an image of the paint sample that shows the distribution of the pigment particles and is consistent with the result obtained from a transmission x-ray microscope. The technique has been experimentally proven to be a feasible coherent x-ray imaging method with about 120 nm spatial resolution and was shown to work well with industrially relevant specimens.

  13. Correlation between protein sequence similarity and x-ray diffraction quality in the protein data bank.

    Science.gov (United States)

    Lu, Hui-Meng; Yin, Da-Chuan; Ye, Ya-Jing; Luo, Hui-Min; Geng, Li-Qiang; Li, Hai-Sheng; Guo, Wei-Hong; Shang, Peng

    2009-01-01

    As the most widely utilized technique to determine the 3-dimensional structure of protein molecules, X-ray crystallography can provide structure of the highest resolution among the developed techniques. The resolution obtained via X-ray crystallography is known to be influenced by many factors, such as the crystal quality, diffraction techniques, and X-ray sources, etc. In this paper, the authors found that the protein sequence could also be one of the factors. We extracted information of the resolution and the sequence of proteins from the Protein Data Bank (PDB), classified the proteins into different clusters according to the sequence similarity, and statistically analyzed the relationship between the sequence similarity and the best resolution obtained. The results showed that there was a pronounced correlation between the sequence similarity and the obtained resolution. These results indicate that protein structure itself is one variable that may affect resolution when X-ray crystallography is used.

  14. Diffractive-refractive optics: (+,-,-,+) X-ray crystal monochromator with harmonics separation.

    Science.gov (United States)

    Hrdý, Jaromír; Mikulík, Petr; Oberta, Peter

    2011-03-01

    A new kind of two channel-cut crystals X-ray monochromator in dispersive (+,-,-,+) position which spatially separates harmonics is proposed. The diffracting surfaces are oriented so that the diffraction is inclined. Owing to refraction the diffracted beam is sagittally deviated. The deviation depends on wavelength and is much higher for the first harmonics than for higher harmonics. This leads to spatial harmonics separation. The idea is supported by ray-tracing simulation.

  15. Long wave-length x-ray diffraction crystal and method of manufacturing same

    International Nuclear Information System (INIS)

    Zingaro, W.P.; Sicignano, A.

    1980-01-01

    An x-ray diffraction crystal of the Langemuir-Blodgett type capable of detecting radiation having a wavelength greater than 50 Arystroms and a method of making such a crystal are described. The crystal consists of a pair of alternate monolayers, one a heavy metal soap, and one a light metal soap. Selecting cation pairs with a significant difference in atomic number and dispersing power, such as Pb and Be, Mg, or Ca, increases the effective interplanar distance since the Pb planes cause the predominant x-ray diffraction. (LL)

  16. An introduction to three-dimensional X-ray diffraction microscopy

    DEFF Research Database (Denmark)

    Poulsen, Henning Friis

    2012-01-01

    Three-dimensional X-ray diffraction microscopy is a fast and nondestructive structural characterization technique aimed at studies of the individual crystalline elements (grains or subgrains) within millimetre-sized polycrystalline specimens. It is based on two principles: the use of highly...... penetrating hard X-rays from a synchrotron source and the application of tomographic reconstruction algorithms for the analysis of the diffraction data. In favourable cases, the position, morphology, phase and crystallographic orientation can be derived for up to 1000 elements simultaneously. For each grain...

  17. X-ray diffraction investigation of spin reorientation in SmFe2

    International Nuclear Information System (INIS)

    Gaviko, V.S.; Korolyov, A.V.; Mushnikov, N.V.

    1996-01-01

    Spontaneous magnetoelastic crystal lattice distortions in the spin reorientation region of high magnetostrictive SmFe 2 have been investigated by X-ray diffraction in the temperature range 80-300 K. Comparison of experimental shapes of X-ray diffraction lines with calculated shapes shows that, in the region of the spin reorientation transition, a mixture of left angle 110 right angle and left angle 111 right angle phases rather than the angular left angle uuw right angle -type phase is realized. The temperature dependence of the relative volume content of left angle 110 right angle and left angle 111 right angle phases is determined using least-squares fitting. (orig.)

  18. X-ray diffraction studies of chitosan acetate-based polymer electrolytes

    International Nuclear Information System (INIS)

    Osman, Z.; Ibrahim, Z.A.; Abdul Kariem Arof

    2002-01-01

    Chitosan is the product when partially deacetylated chitin dissolves in dilute acetic acid. This paper presents the x-ray diffraction patterns of chitosan acetate, plasticised chitosan acetate and plasticised-salted chitosan acetate films. The results show that the chitosan acetate based polymer electrolyte films are not completely amorphous but it is partially crystalline. X-ray diffraction study also confirms the occurrence of the complexation between chitosan and the salt and the interaction between salt and plasticizer. The salt-chitosan interaction is clearly justified by infrared spectroscopy. (Author)

  19. Determination of densities from chemical composition and X-Ray diffraction

    International Nuclear Information System (INIS)

    Azevedo, A.L.T. de

    1980-01-01

    X-ray diffraction method applied to retained austenite measurements gives volume per cent results, whereas the same kind of measurement made by Moessbauer Effect gives iron percentages. To compare both results one needs to convert the volume % to weight % or vice-versa. This necessitates, among other things, in determining the densities of the α and #betta# phases in the steel being studied. A method for calculating the densities, based on the application of the definition of density to just one unit cell, using X-ray diffraction and chemical results, are described. (Author) [pt

  20. Introducing the ARL X'Tra x-ray diffraction system

    International Nuclear Information System (INIS)

    Harris, L.

    2002-01-01

    Full text: The ARL X'Tra is a state-of-the-art solution for powder X-ray diffraction in a large range of applications such as pharmaceuticals and biosciences, chemicals, earth sciences, semi-conductors, metallurgy and ceramics. The X'Tra offers the latest technology in key diffraction components to produce a high performance instrument at an affordable price. This presentation examines some of the hardware and performance features of this instrument. Copyright (2002) Australian X-ray Analytical Association Inc

  1. Magnetic x-ray circular dichroism in spin-polarized photoelectron diffraction

    International Nuclear Information System (INIS)

    Waddill, G.D.; Tobin, J.G.

    1994-01-01

    The first structural determination with spin-polarized, energy-dependent photoelectron diffraction using circularly-polarized x-rays is reported for Fe films on Cu(001). Circularly-polarized x-rays produced spin-polarized photoelectrons from the Fe 2p doublet, and intensity asymmetries in the 2p 3/2 level are observed. Fully spin-specific multiple scattering calculations reproduced the experimentally-determined energy and angular dependences. A new analytical procedure which focuses upon intensity variations due to spin-dependent diffraction is introduced. A sensitivity to local geometric and magnetic structure is demonstrated

  2. Time-resolved x-ray diffraction measurements of high-density InAs quantum dots on Sb/GaAs layers and the suppression of coalescence by Sb-irradiated growth interruption

    International Nuclear Information System (INIS)

    Kakuda, Naoki; Yamaguchi, Koichi; Kaizu, Toshiyuki; Takahasi, Masamitu; Fujikawa, Seiji

    2010-01-01

    Self-assembly of high-density InAs quantum dots (QDs) on Sb-irradiated GaAs buffer layers was observed in-situ by a time-resolved X-ray diffraction (XRD) technique using a combination of XRD and molecular beam epitaxy. Evolution of dot height and lattice constant was analyzed during InAs QD growth and subsequent growth interruption (GI), and as a result, dislocated giant dots due to coalescence and coherent dots were separately evaluated. An Sb-irradiated GI (Sb-GI) method to be applied after InAs growth was attempted for the suppression of coalescence. Using this method, the XRD intensity of giant dots decreased, and the photoluminescence intensity of InAs QDs was enhanced. High-density InAs QDs without giant dots were produced by using the combination of the QD growth on the Sb-irradiated GaAs buffer layers and the Sb-GI. (author)

  3. X-ray topography using the forward transmitted beam under multiple-beam diffraction conditions

    Energy Technology Data Exchange (ETDEWEB)

    Tsusaka, Y., E-mail: tsusaka@sci.u-hyogo.ac.jp; Takano, H. [Graduate School of Material Science, University of Hyogo, 3-2-1, Kouto, Kamigori, Hyogo 678-1297 (Japan); Takeda, S. [SPring-8 Service Co., Ltd., 1-20-5, Kouto, Shingu, Tatsuno, Hyogo 679-5165 (Japan); Yokoyama, K.; Matsui, J. [Synchrotron Radiation Nanotechnology Center, University of Hyogo, 1-490-2, Kouto, Shingu, Tatsuno, Hyogo 679-5165 (Japan); Kagoshima, Y. [Graduate School of Material Science, University of Hyogo, 3-2-1, Kouto, Kamigori, Hyogo 678-1297 (Japan); Synchrotron Radiation Nanotechnology Center, University of Hyogo, 1-490-2, Kouto, Shingu, Tatsuno, Hyogo 679-5165 (Japan)

    2016-02-15

    X-ray topographs are taken for a sapphire wafer with the [0001] surface normal, as an example, by forward transmitted synchrotron x-ray beams combined with two-dimensional electronic arrays in the x-ray detector having a spatial resolution of 1 μm. They exhibit no shape deformation and no position shift of the dislocation lines on the topographs. Since the topography is performed under multiple-beam diffraction conditions, the topographic images of a single diffraction (two-wave approximation condition) or plural diffractions (six-wave approximation condition) can be recorded without large specimen position changes. As usual Lang topographs, it is possible to determine the Burgers vector of each dislocation line. Because of high parallelism of the incoming x-rays and linear sensitivity of the electronic arrays to the incident x-rays, the present technique can be used to visualize individual dislocations in single crystals of the dislocation density as high as 1 × 10{sup 5} cm{sup −2}.

  4. Femtosecond X-ray diffraction from two-dimensional protein crystals

    Directory of Open Access Journals (Sweden)

    Matthias Frank

    2014-03-01

    Full Text Available X-ray diffraction patterns from two-dimensional (2-D protein crystals obtained using femtosecond X-ray pulses from an X-ray free-electron laser (XFEL are presented. To date, it has not been possible to acquire transmission X-ray diffraction patterns from individual 2-D protein crystals due to radiation damage. However, the intense and ultrafast pulses generated by an XFEL permit a new method of collecting diffraction data before the sample is destroyed. Utilizing a diffract-before-destroy approach at the Linac Coherent Light Source, Bragg diffraction was acquired to better than 8.5 Å resolution for two different 2-D protein crystal samples each less than 10 nm thick and maintained at room temperature. These proof-of-principle results show promise for structural analysis of both soluble and membrane proteins arranged as 2-D crystals without requiring cryogenic conditions or the formation of three-dimensional crystals.

  5. New software to model energy dispersive X-ray diffraction in polycrystalline materials

    Energy Technology Data Exchange (ETDEWEB)

    Ghammraoui, B., E-mail: bahaa.ghammraoui@cea.fr [CEA-Leti, MINATEC Campus, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Tabary, J. [CEA-Leti, MINATEC Campus, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Pouget, S. [CEA-INAC Sciences de la matieres, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Paulus, C.; Moulin, V.; Verger, L. [CEA-Leti, MINATEC Campus, 17 rue des Martyrs, F 38054 Grenoble, Cedex 9 (France); Duvauchelle, Ph. [CNDRI-Insa Lyon, Universite de Lyon, F-69621, Villeurbanne Cedex (France)

    2012-02-01

    Detection of illicit materials, such as explosives or drugs, within mixed samples is a major issue, both for general security and as part of forensic analyses. In this paper, we describe a new code simulating energy dispersive X-ray diffraction patterns in polycrystalline materials. This program, SinFullscat, models diffraction of any object in any diffractometer system taking all physical phenomena, including amorphous background, into account. Many system parameters can be tuned: geometry, collimators (slit and cylindrical), sample properties, X-ray source and detector energy resolution. Good agreement between simulations and experimental data was obtained. Simulations using explosive materials indicated that parameters such as the diffraction angle or the energy resolution of the detector have a significant impact on the diffraction signature of the material inspected. This software will be a convenient tool to test many diffractometer configurations, providing information on the one that best restores the spectral diffraction signature of the materials of interest.

  6. Two new tensile devices for X-ray diffraction experiments

    International Nuclear Information System (INIS)

    Freri, N.; Tintori, A.; Depero, L.E.; Sangaletti, L.; Cernuschi, F.; Ghia, S.

    1995-12-01

    Two tensile devices were designed to be used with parallel beam and parafocusing-geometry diffractometers. In the first case the device was designed to be attached to a strainflex diffractometer by Rigaku Inc., dedicated to stress analysis and commonly used in metallurgical industry. Since the sample does not move during the measurement, the tensile device can be kept fixed on the experimental table. The device design takes into account the steric hindrance by moving parts of diffractometer. The maximun load that can be applied to the sample is 60.000 N. An attachement to a Siemens D5000 diffractometer with Eulerian cradle has also benn designed for applying a load up tp 6000 N to a sample in the parafocusing-geometry. The installation does not require a re-alignment of the diffractometer. In both cases strain gages were applied to both sides of the specimen for the simultaneous determination of the macroscopic strains. Experiments based on the use of these devices are planned to determine the crystallographic elastic constants and study the influence of the microstructure on the mechanical behaviour of residual stresses in the zone of almost static stresses as well as the influence of residual stresses on uniaxially loaded samples. In addition, by using these devices, it is possible to measure the unstressed d-0 spacings providing useful information in the neutron diffraction study fo stress fields in steel samples

  7. Two new tensile devices for X-ray diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Freri, N.; Tintori, A.; Depero, L.E.; Sangaletti, L. [Brescia Univ. (Italy); Cernuschi, F.; Ghia, S. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-12-01

    Two tensile devices were designed to be used with parallel beam and parafocusing-geometry diffractometers. In thefirst case the device was designed to be attached to a strainflex diffractometer by Rigaku Inc., dedicated to stress analysis and commonly used in metallurgical industry. Since the sample does not move during the measurement, the tensile device can be kept fixed on the experimental table. The device design takes into account the steric hindrance by moving parts of diffractometer. The maximun load that can be applied to the sample is 60.000 N. An attachement to a Siemens D5000 diffractometer with Eulerian cradle has also benn designed for applying a load up tp 6000 N to a sample in the parafocusing-geometry. The installation does not require a re-alignment of the diffractometer. In both cases strain gages were applied to both sides of the specimen for the simultaneous determination of the macroscopic strains. Experiments based on the use of these devices are planned to determine the crystallographic elastic constants and study the influence of the microstructure on the mechanical behaviour of residual stresses in the zone of almost static stresses as well as the influence of residual stresses on uniaxially loaded samples. In addition, by using these devices, it is possible to measure the unstressed d-0 spacings providing useful information in the neutron diffraction study fo stress fields in steel samples.

  8. Coded diffraction system in X-ray crystallography using a boolean phase coded aperture approximation

    Science.gov (United States)

    Pinilla, Samuel; Poveda, Juan; Arguello, Henry

    2018-03-01

    Phase retrieval is a problem present in many applications such as optics, astronomical imaging, computational biology and X-ray crystallography. Recent work has shown that the phase can be better recovered when the acquisition architecture includes a coded aperture, which modulates the signal before diffraction, such that the underlying signal is recovered from coded diffraction patterns. Moreover, this type of modulation effect, before the diffraction operation, can be obtained using a phase coded aperture, just after the sample under study. However, a practical implementation of a phase coded aperture in an X-ray application is not feasible, because it is computationally modeled as a matrix with complex entries which requires changing the phase of the diffracted beams. In fact, changing the phase implies finding a material that allows to deviate the direction of an X-ray beam, which can considerably increase the implementation costs. Hence, this paper describes a low cost coded X-ray diffraction system based on block-unblock coded apertures that enables phase reconstruction. The proposed system approximates the phase coded aperture with a block-unblock coded aperture by using the detour-phase method. Moreover, the SAXS/WAXS X-ray crystallography software was used to simulate the diffraction patterns of a real crystal structure called Rhombic Dodecahedron. Additionally, several simulations were carried out to analyze the performance of block-unblock approximations in recovering the phase, using the simulated diffraction patterns. Furthermore, the quality of the reconstructions was measured in terms of the Peak Signal to Noise Ratio (PSNR). Results show that the performance of the block-unblock phase coded apertures approximation decreases at most 12.5% compared with the phase coded apertures. Moreover, the quality of the reconstructions using the boolean approximations is up to 2.5 dB of PSNR less with respect to the phase coded aperture reconstructions.

  9. Dichroism and resonant diffraction in x-ray scattering by complex materials

    International Nuclear Information System (INIS)

    Collins, S P; Lovesey, S W; Balcar, E

    2007-01-01

    We survey universal concepts that influence dichroism and resonant Bragg diffraction, aiming to reach across the range of scientific disciplines that benefit from x-ray techniques, namely, chemistry, physics, life-sciences, and the science of materials. To this end, we adopt a top down discussion of the aspects of symmetry and concomitant selection rules. Starting from selection rules that can be deduced from the global condition that an observable quantity is unchanged on reversing the directions of both space and time separately, to selection rules that flow from bulk symmetry properties of electrons imposed by elements of a point group or crystal class to, finally, atomic selection rules that emerge from the details of the electronic structure. As a motivation for the latter we discuss, with a new calculation of the x-ray scattering length, E 1-M 1 absorption and scattering events that particularly interest scientists studying the chirality of life. In the main text there is modest use of mathematics, with appropriate details relegated to a few appendices. (topical review)

  10. Interactive processing of x-ray diffraction maxima (exchange of experience)

    International Nuclear Information System (INIS)

    Zabolotnyi, V.A.; Moroz, E.M.

    1993-01-01

    A program package for primary processing of the curve of intensity of x-ray dispersion has been developed and tested within the framework of creating computer programs that are compatible with IBM/PC/XT/AT computers for calculation and modeling of randial distributions of atoms. The following calculations have been included in this package: determination of the positions of maxima; separation of the maxima; and calculation of the integral characteristics of components. This paper describes the main feature of the algorithm, which is the procedure for varying the form of components, each of which is represented as a sum of two Gaussians with differing half-width ad amplitude. Use of the described method of modeling of the x-ray diffraction maximum was found effective in most of the practically important cases. To illustrate the operation of the program the results of approximation of a pentaplet of quartz obtained in CuKα-radiation with 0.01 degrees scanning step and 20 sec build-up time (40 kV; 40 mA; HZG-4C) are presented. 3 refs., 2 figs., 1 tab

  11. X-ray diffraction, Raman, and photoacoustic studies of ZnTe nanocrystals

    Science.gov (United States)

    Ersching, K.; Campos, C. E. M.; de Lima, J. C.; Grandi, T. A.; Souza, S. M.; da Silva, D. L.; Pizani, P. S.

    2009-06-01

    Nanocrystalline ZnTe was prepared by mechanical alloying. X-ray diffraction (XRD), energy dispersive spectroscopy, Raman spectroscopy, and photoacoustic absorption spectroscopy techniques were used to study the structural, chemical, optical, and thermal properties of the as-milled powder. An annealing of the mechanical alloyed sample at 590 °C for 6 h was done to investigate the optical properties in a defect-free sample (close to bulk form). The main crystalline phase formed was the zinc-blende ZnTe, but residual trigonal tellurium and hexagonal ZnO phases were also observed for both as-milled and annealed samples. The structural parameters, phase fractions, average crystallite sizes, and microstrains of all crystalline phases were obtained from Rietveld analyses of the X-ray patterns. Raman results corroborate the XRD results, showing the longitudinal optical phonons of ZnTe (even at third order) and those modes of trigonal Te. Nonradiative surface recombination and thermal bending heat transfer mechanisms were proposed from photoacoustic analysis. An increase in effective thermal diffusivity coefficient was observed after annealing and the carrier diffusion coefficient, the surface recombination velocity, and the recombination time parameters remained the same.

  12. First steps of ion beam mixing: study by X-ray reflectometry and neutron diffraction

    International Nuclear Information System (INIS)

    Le Boite, M.G.

    1987-12-01

    There are several processes involved in ion beam mixing: ballistic processes, chemical driving forces and radiation enhanced diffusion. Experiments usually performed on bilayers irradiated with heavy elements and characterized by Rutherford backscattering (R.B.S.), have shown that the measured mixing rate is always higher than the calculated one, taking into account ballistic effects only. Besides classical R.B.S. experiments on NiAu and NiPt bilayers irradiated with Xe, we have used another technique of characterization: X-ray reflectometry and neutron diffraction, performed on multilayers irradiated with He. The systems are NiAu, NiPt, NiPd and NiAg, which behave similarly from the ballistic point of view, but have very different heats of mixing. In these experiments, the range of deposited energy density is very low, in contrast to heavy ions irradiation: this has allowed us to reach very low diffusion coefficient, never observed before. The dependence of the diffusion coefficient on the heat of mixing is in agreement with the one theoretically calculated. For the NiAg system, which has a positive heat of mixing, the measured diffusion coefficient is smaller than the ballistic one: a decrease of the ballistic mixing rate is seen for the first time. In this work, we have shown the interest of the reflectometry techniques (X-ray and neutrons); we have used a simple model to analyze the ion beam mixing, when elementary processes are involved

  13. Characterisation of microfocused beam for synchrotron powder diffraction using a new X-ray camera

    International Nuclear Information System (INIS)

    Thomas, C; Potter, J; Tang, C C; Lennie, A R

    2012-01-01

    The powder diffraction beamline I11, Diamond Light Source, is being continually upgraded as requirements of the user community evolve. Intensities of X-rays from the I11 in-vacuum electron undulator in the 3 GeV synchrotron fall off at higher energies. By focusing higher energy X-rays, we can overcome flux limitations, and open up new diffraction experiments. Here, we describe characterisation of microfocusing using compound refractive lenses (CRL). For a relatively modest outlay, we have developed an experimental setup and a novel X-ray camera with good sensitivity and a resolution specification suitable for characterising these focusing optics. We show that vertical oscillations in the focused beam compromise resolution of the source imaged by the CRL. Nevertheless, we have measured CRL focusing properties, and demonstrate the use of energy scanning to determine lens alignment. Real benefits of the intensity gain are illustrated.

  14. Soft x-ray resonant magnetic powder diffraction on PrNiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Staub, U [Swiss Light Source, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); GarcIa-Fernandez, M [Swiss Light Source, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Mulders, A M [Department of Applied Physics, Curtin University of Technology, GPO Box U1987, Perth WA 6845 (Australia); Bodenthin, Y [Swiss Light Source, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); MartInez-Lope, M J [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, E-28049 Madrid (Spain); Alonso, J A [Instituto de Ciencia de Materiales de Madrid, CSIC, Cantoblanco, E-28049 Madrid (Spain)

    2007-03-07

    We report on the first soft x-ray resonant powder diffraction experiments performed at the Ni L{sub 2,3} edges of PrNiO{sub 3}. The temperature, polarization and energy dependence of the (1/2 0 1/2) reflection indicates a magnetic origin for the signal. This experiment demonstrates that x-ray resonant magnetic powder diffraction can be relatively easily performed in the soft x-ray regime due to the very large enhancement factors at the absorption edges. Such experiments allow us to extract important information on the electronic states of the d shell. Similar results can be anticipated from orbital reflections measured in a powder. (fast track communication)

  15. Hydrogen atoms in protein structures: high-resolution X-ray diffraction structure of the DFPase

    Science.gov (United States)

    2013-01-01

    Background Hydrogen atoms represent about half of the total number of atoms in proteins and are often involved in substrate recognition and catalysis. Unfortunately, X-ray protein crystallography at usual resolution fails to access directly their positioning, mainly because light atoms display weak contributions to diffraction. However, sub-Ångstrom diffraction data, careful modeling and a proper refinement strategy can allow the positioning of a significant part of hydrogen atoms. Results A comprehensive study on the X-ray structure of the diisopropyl-fluorophosphatase (DFPase) was performed, and the hydrogen atoms were modeled, including those of solvent molecules. This model was compared to the available neutron structure of DFPase, and differences in the protein and the active site solvation were noticed. Conclusions A further examination of the DFPase X-ray structure provides substantial evidence about the presence of an activated water molecule that may constitute an interesting piece of information as regard to the enzymatic hydrolysis mechanism. PMID:23915572

  16. X-ray diffraction on nanoparticles chromium and nickel oxides obtained by gelatin using synchrotron radiation

    International Nuclear Information System (INIS)

    Menezes, Alan Silva de; Medeiros, Angela Maria de Lemos; Miranda, Marcus Aurelio Ribeiro; Almeida, Juliana Marcela Abraao; Remedios, Claudio Marcio Rocha; Silva, Lindomar R.D. da; Gouveia, S.T.; Sasaki, Jose Marcos; Jardim, P.M.

    2003-01-01

    Full text: Cr 2 O 3 nanoparticles has many applications like green pigments, wear resistance, and coating materials for thermal protection. Several methods to produce chromium oxide nanoparticles have already been studied, gas condensation, laser induced pyrolysis, microwave plasma, sol-gel and gamma radiation methods. Many applications for this kind of material can be provide concerning the particle size. For instance, particle size approximately of 200 nm are preferable as pigment due to its opacity and below 50 nm can be used as transparent pigment. In this work we have demonstrated that chromium and nickel oxide nanoparticles can be prepared by gelatin method. X-Ray diffraction (XRD) show that mean particle size for chromium oxide of 15-150 nm and nickel oxide of 90 nm were obtained for several temperature of sintering. The X-Ray powder diffraction pattern were performed using Synchrotron Radiation X-Ray source at XRD1 beamline in National Laboratory of Light Synchrotron (LNLS). (author)

  17. In situ laser heating and radial synchrotron X-ray diffraction ina diamond anvil cell

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Martin; Caldwell, Wendel A.; Miyagi, Lowell; Wenk,Hans-Rudolf

    2007-06-29

    We report a first combination of diamond anvil cell radialx-ray diffraction with in situ laser heating. The laser-heating setup ofALS beamline 12.2.2 was modified to allow one-sided heating of a samplein a diamond anvil cell with an 80 W yttrium lithium fluoride laser whileprobing the sample with radial x-ray diffraction. The diamond anvil cellis placed with its compressional axis vertical, and perpendicular to thebeam. The laser beam is focused onto the sample from the top while thesample is probed with hard x-rays through an x-ray transparentboron-epoxy gasket. The temperature response of preferred orientation of(Fe,Mg)O is probed as a test experiment. Recrystallization was observedabove 1500 K, accompanied by a decrease in stress.

  18. X-ray diffraction patterns of single crystals implanted with high-energy light ions

    International Nuclear Information System (INIS)

    Wieteska, K.

    1998-01-01

    X-ray diffraction patterns of silicon and gallium arsenide single crystals implanted with high-energy protons and α-particles were studied. A various models of lattice parameter changes were analysed. The agreement between the simulation and experiment proves that the lattice parameter depth-distribution can be assumed to be proportional to vacancy distribution obtained by Monte-Carlo method and from the Biersack-Ziegler theory. Most of the X-ray experiments were performed using synchrotron source of X-ray radiation in particular in the case of back-reflection and transmission section topographic methods. The new method of direct determination of the implanted ion ranges was proposed using synchrotron radiation back-reflection section topography. A number of new interference phenomena was revealed and explained. These interferences are important in the applications of diffraction theory in studying of the real structure of implanted layers. (author)

  19. X-ray diffraction of slag-based sodium salt waste forms

    Energy Technology Data Exchange (ETDEWEB)

    Langton, C. A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Missimer, D. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-09-30

    The attached report documents sample preparation and x-ray diffraction results for a series of cement and blended cement matrices prepared with either water or a 4.4 M Na salt solution. The objective of the study was to provide initial phase characterization for the Cementitious Barriers Partnership reference case cementitious salt waste form. This information can be used to: 1) generate a base line for the evolution of the waste form as a function of time and conditions, 2) potentially to design new binders based on mineralogy of the binder, 3) understand and predict anion and cation leaching behavior of contaminants of concern, and 4) predict performance of the waste forms for which phase solubility and thermodynamic data are available.

  20. Quantitative studies of the nucleation of recrystallization in metals utilizing microscopy and X-ray diffraction

    DEFF Research Database (Denmark)

    Larsen, Axel Wright

    is proven to be a good way of determining microstructural parameters, which are important when studying recrystallization dynamics. The nucleation of recrystallizationat triple junctions has been studied by 3 dimensional X-ray diffraction (3DXRD), allowing for the first time the deformed and recrystallized......This thesis covers three main results obtained during the project: A reliable method of performing serial sectioning on metal samples utilizing a Logitech polishing machine has been developed. Serial sectioning has been performed on metal samples in 1 µmsteps utilizing mechanical polishing...... microstructures to be compared at a given nucleation site in the bulk of a metal sample. From an experiment threenuclei were identified, their respective crystal orientations were determined, and growth curves were obtained for two of them....

  1. Local layer structure of smectic liquid crystals by X-ray micro-diffraction

    CERN Document Server

    Takanishi, Y

    2003-01-01

    The local layer structure of smectic liquid crystal has been measured using time-resolved synchrotron X-ray micro-diffraction. Typical layer disorders observed in surface stabilized (anti-) ferroelectric liquid crystals, i.e. a stripe texture, a needed-like defect and a zigzag defect, are directly analyzed. The detailed analysis slows that the surface anchoring force due to the interaction between the liquid crystal molecule and the alignment thin film plays an important role to realize both the static and dynamic local layer structures. The layer structure of the circular domain observed in the liquid crystal of bent-shaped molecules found to depend on the applied electric field though the optical micrograph shows little difference. The frustrated, double and single layer structures of the bent-shaped molecule liquid crystal are determined depending on the terminal alkyl chain length. (author)

  2. Residual stress evaluation and fatigue life prediction in the welded joint by X-ray diffraction

    International Nuclear Information System (INIS)

    Yoo, Keun Bong; Kim, Jae Hoon

    2009-01-01

    In the fossil power plant, the reliability of the components which consist of the many welded parts depends on the quality of welding. The residual stress is occurred by the heat flux of high temperature during weld process. This decreases the mechanical properties as the strength of fatigue and fracture or occurs the stress corrosion cracking and fatigue fracture. The residual stress of the welded part in the recently constructed power plants has been the cause of a variety of accidents. The objective of this study is measurement of the residual stress by X-ray diffraction method and to estimate the feasibility of this application for fatigue life assessment of the high-temperature pipeline. The materials used for the study is P92 steel for the use of high temperature pipe on super critical condition. The test results were analyzed by the distributed characteristics of residual stresses and the Full Width at Half Maximum intensity (FWHM) in x-ray diffraction intensity curve. Also, X-ray diffraction tests using specimens simulated low cycle fatigue damage were performed in order to analyze fatigue properties when fatigue damage conditions become various stages. As a result of X-ray diffraction tests for specimens simulated fatigue damages, we conformed that the ratio of the FWHM due to fatigue damage has linear relationship with fatigue life ratio algebraically. From this relationships, it was suggested that direct expectation of the life consumption rate was feasible.

  3. Small angles X-ray diffraction and Mössbauer characterization of ...

    Indian Academy of Sciences (India)

    Abstract. The effect of thermal annealing on the structure and magnetic properties of crystalline Tb/Fe multilayers has been studied using conversion electron Mössbauer spectrometry and small-angle X-ray diffraction. The growth of Tb–Fe amorphous alloy from the interface is observed with increasing annealing ...

  4. A structural view of Pd model catalysts : high-pressure surface X-Ray diffraction

    NARCIS (Netherlands)

    Rijn, Richard van

    2012-01-01

    This thesis describes the development of a combined high-pressure/ultrahigh-vacuum flow reactor for the study of model catalysts by means of surface x-ray diffraction and grazing incidence small angle scattering. The system was used to measure a stability diagram for the different oxide phases

  5. Quantitative phase analysis of uranium carbide from x-ray diffraction data using the Rietveld method

    International Nuclear Information System (INIS)

    Singh Mudher, K.D.; Krishnan, K.

    2003-01-01

    Quantitative phase analysis of a uranium carbide sample was carried out from the x-ray diffraction data by Rietveld profile fitting method. The method does not require the addition of any reference material. The percentage of UC, UC 2 and UO 2 phases in the sample were determined. (author)

  6. Study of caprine bones after moist and dry heat processes by X-ray diffraction

    International Nuclear Information System (INIS)

    Barbosa, Caroline M.; Azeredo, Soraia R.; Lopes, Ricardo T.; Souza, Sheila M.F.M de

    2013-01-01

    Bone tissue is a biological material composed of hydroxyapatite (HAp) and collagen matrix. The bone X-ray diffraction (XRD) pattern presents characteristics of the hydroxyapatite crystallography planes. This paper presents the characterization by X-ray diffraction of caprine bone powder pattern and the comparison of this pattern with moist or dry heat cooked bone patterns. The parameters chosen to characterize the X-ray diffraction peaks were: angular position (2θ), full width at half maximumt (FWHM), and relative intensity (I rel ). The X-ray diffraction patterns were obtained with a Shimadzu XRD-6000 diffractometer. The caprine bone XRD pattern revealed a significant correlation of several crystallographic parameters (lattice data) with hydroxyapatite. The profiles of the three bone types analyzed presented differences. The study showed as small angular displacement (decrease of the 2θ angle) of some peaks was observed after moist and dry heat cooking processes. The characterization of bone tissue aimed to contribute to future analysis in the field of archeology. (author)

  7. Mössbauer effect studies and X-ray diffraction analysis of cobalt ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 26; Issue 5. Mössbauer effect studies and X-ray diffraction analysis of cobalt ferrite prepared in powder form by thermal decomposition method. M D Joseph Sebastian B Rudraswamy M C Radhakrishna Ramani. Magnetic Materials Volume 26 Issue 5 August 2003 pp ...

  8. High-pressure X-ray diffraction of L-ALANINE crystal

    DEFF Research Database (Denmark)

    Olsen, J.S.; Gerward, Leif; Souza, A.G.

    2006-01-01

    L-ALANINE has been studied by X-ray diffraction at ambient temperature and pressure up to 10.3 GPa. The material is found to transform to a tetragonal structure between 2 and 3 GPa. and to a monoclinic structure between 8 and 10 GPa. The experimental bulk modulus is 25(5) GPa for the orthorhombic...

  9. Small angles X-ray diffraction and Mössbauer characterization of ...

    Indian Academy of Sciences (India)

    The effect of thermal annealing on the structure and magnetic properties of crystalline Tb/Fe multilayers has been studied using conversion electron Mössbauer spectrometry and small-angle X-ray diffraction. The growth of Tb–Fe amorphous alloy from the interface is observed with increasing annealing temperature.

  10. A greedy method for reconstructing polycrystals from three-dimensional X-ray diffraction data

    DEFF Research Database (Denmark)

    Kulshreshth, Arun Kumar; Alpers, Andreas; Herman, Gabor T.

    2009-01-01

    An iterative search method is proposed for obtaining orientation maps inside polycrystals from three-dimensional X-ray diffraction (3DXRD) data. In each step, detector pixel intensities are calculated by a forward model based on the current estimate of the orientation map. The pixel at which...

  11. Non-destructive characterization of recrystallization kinetics using three-dimensional X-ray diffraction microscopy

    DEFF Research Database (Denmark)

    Lauridsen, E.M.; Schmidt, Søren; Fæster Nielsen, Søren

    2006-01-01

    Three-dimensional X-ray diffraction (3DXRD) is used to characterize the nucleation and early growth of individual bulk nuclei in situ during recrystallization of 92% cold-rolled copper. It is found that some cube nuclei, but not all, have a significantly faster initial growth than the average...

  12. Determining grain resolved stresses in polycrystalline materials using three-dimensional X-ray diffraction

    DEFF Research Database (Denmark)

    Oddershede, Jette; Schmidt, Søren; Poulsen, Henning Friis

    2010-01-01

    An algorithm is presented for characterization of the grain resolved (type II) stress states in a polycrystalline sample based on monochromatic X-ray diffraction data. The algorithm is a robust 12-parameter-per-grain fit of the centre-of-mass grain positions, orientations and stress tensors...

  13. Simultaneous X-ray diffraction from multiple single crystals of macromolecules

    DEFF Research Database (Denmark)

    Paithankar, Karthik S.; Sørensen, Henning Osholm; Wright, Jonathan P.

    2011-01-01

    The potential in macromolecular crystallography for using multiple crystals to collect X-ray diffraction data simultaneously from assemblies of up to seven crystals is explored. The basic features of the algorithms used to extract data and their practical implementation are described. The procedure...

  14. Caracterization of the crystalline phases by X-Ray diffraction in electrode coatings

    International Nuclear Information System (INIS)

    Neves, M.C.G.P.; Souza Caillaux, Z. de

    1981-01-01

    Some electrodes and their respective coatings were studied in order to verify their compatibility with their utilization in the welding of base metals appropriate for the equipment of sugar and alcohol plants. The carried out studies include the characterization, by X-ray diffraction, of crystaline phases, existent in electrodes coatings. (Author) [pt

  15. Study of caprine bones after moist and dry heat processes by X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Caroline M., E-mail: carolmattosb@yahoo.com.br [Instituto de Arqueologia Brasileira (IAB), Belford Roxo, RJ (Brazil); Azeredo, Soraia R.; Lopes, Ricardo T., E-mail: soraia@lin.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/LIN/UFRJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Instrumentacao Nuclear; Souza, Sheila M.F.M de, E-mail: sferraz@ensp.fiocruz.br [Fundacao Oswaldo Cruz (ENSP/FIOCRUZ), Rio de Janeiro, RJ (Brazil). Escola Nacional de Saude Publica Sergio Arouca

    2013-07-01

    Bone tissue is a biological material composed of hydroxyapatite (HAp) and collagen matrix. The bone X-ray diffraction (XRD) pattern presents characteristics of the hydroxyapatite crystallography planes. This paper presents the characterization by X-ray diffraction of caprine bone powder pattern and the comparison of this pattern with moist or dry heat cooked bone patterns. The parameters chosen to characterize the X-ray diffraction peaks were: angular position (2θ), full width at half maximumt (FWHM), and relative intensity (I{sub rel}). The X-ray diffraction patterns were obtained with a Shimadzu XRD-6000 diffractometer. The caprine bone XRD pattern revealed a significant correlation of several crystallographic parameters (lattice data) with hydroxyapatite. The profiles of the three bone types analyzed presented differences. The study showed as small angular displacement (decrease of the 2θ angle) of some peaks was observed after moist and dry heat cooking processes. The characterization of bone tissue aimed to contribute to future analysis in the field of archeology. (author)

  16. High-pressure phases of uranium monophosphide studied by synchrotron x-ray diffraction

    DEFF Research Database (Denmark)

    Olsen, J. Staun; Gerward, Leif; Benedict, U.

    1988-01-01

    X-ray diffraction studies have been performed on UP powder for pressures up to 51 GPa using synchrotron radiation and a diamond-anvil cell. At ambient pressure UP has the rocksalt structure. The bulk modulus has been determined to B0=102(4) GPa and its pressure derivative to B0’=4.0(8). The cubic...

  17. A three-dimensional X-ray diffraction microscope for deformation studies of polycrystals

    DEFF Research Database (Denmark)

    Fæster Nielsen, Søren; Lauridsen, E.M.; Juul Jensen, D.

    2001-01-01

    -dimensional X-ray diffraction (3DXRD) microscope installed at the European Synchrotron Radiation Facility in Grenoble provides a fast and non-destructive technique for mapping the embedded grains within thick samples in three dimensions. All essential features like the position, volume, orientation, stress...

  18. Characterization of calcium crystals in Abelia using x-ray diffraction and electron microscopes

    Science.gov (United States)

    Localization, chemical composition, and morphology of calcium crystals in leaves and stems of Abelia mosanensis and A. ×grandiflora were analyzed with a variable pressure scanning electron microscope (VP-SEM) equipped with an X-ray diffraction system, low temperature SEM (LT-SEM) and a transmission ...

  19. Hut clusters on Ge(001) surfaces studied by STM and synchrotron X-ray diffraction

    DEFF Research Database (Denmark)

    Nielsen, M.; Smilgies, D.-M.; Feidenhans'l, R.

    1996-01-01

    Nanoscale hut clusters formed on Ge(001) surfaces by depositing one monolayer of indium and annealing at temperatures between 350 and 500 degrees C were studied by scanning tunnelling microscopy and synchrotron X-ray diffraction. It was found that the hut clusters form regular arrays over...

  20. Moessbauer spectroscopy, X-ray diffraction and infrared studies of prehistoric materials from Minas Gerais

    International Nuclear Information System (INIS)

    Jesus Filho, M.F. de; Costa, G.M. da; Prous, A.

    1988-01-01

    Eight samples of pigmented materials from an archaelogical site in Santana do Riacho (Minas Gerais, Brazil) were studied by X-ray diffraction, infrared and Moessbauer spectroscopy. These three techniques and the results of chemical analysis allowed the approximated composition of each sample to be proposed. No trace of organic material was found in any sample. (author)

  1. Crystallization Kinetics of Nanocrystalline Materials by Combined X-ray Diffraction and Differential Scanning Calorimetry Experiments

    Czech Academy of Sciences Publication Activity Database

    Gil-González, E.; Perejón, A.; Sánchez-Jiménez, P. E.; Medina-Carrasco, S.; Kupčík, Jaroslav; Šubrt, Jan; Criado, J. M.; Pérez-Maqueda, L. A.

    2018-01-01

    Roč. 18, č. 5 (2018), s. 3107-3116 ISSN 1528-7483 Institutional support: RVO:61388980 Keywords : nanocrysalline alloys * combined X ray diffraction * crystallization kinetics Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 4.055, year: 2016

  2. Evaluated Plan Stress Of Weld In Pressure Tube Using X Ray Diffraction Technique

    International Nuclear Information System (INIS)

    Phan Trong Phuc; Nguyen Duc Thanh; Luu Anh Tuyen

    2011-01-01

    X ray diffraction is a fundamental technique measuring stress, this technique has determined crystal strain in materials, from that determined stress in materials. This paper presents study of evaluating plane stress of weld in pressure tube, using modern XRD apparatus: X Pert Pro. (author)

  3. Revealing stacking sequences in inverse opals by microradian X-ray diffraction

    NARCIS (Netherlands)

    Sinitskii, A.; Abramova, V.; Grigorieva, N.; Grigoriev, S.; Snigirev, A.; Byelov, D.; Petukhov, A.V.

    2010-01-01

    We present the results of the structural analysis of inverse opal photonic crystals by microradian X-ray diffraction. Inverse opals based on different oxide materials (TiO2, SiO2 and Fe2O3) were fabricated by templating polystyrene colloidal crystal films grown by the vertical deposition technique.

  4. Purification, crystallization and preliminary X-ray diffraction experiment of nattokinase from Bacillus subtilis natto

    OpenAIRE

    Yanagisawa, Yasuhide; Chatake, Toshiyuki; Chiba-Kamoshida, Kaori; Naito, Sawa; Ohsugi, Tadanori; Sumi, Hiroyuki; Yasuda, Ichiro; Morimoto, Yukio

    2010-01-01

    Nattokinase, a protein found in high levels in the traditional Japanese food natto, has been reported to have high thrombolytic activity. In the present study, the crystallization of native nattokinase and the collection of X-ray diffraction date from a nattokinase crystal to a resolution of 1.74 Å are reported.

  5. X-ray diffraction studies of sucrose and sucrose irradiated with γ-radiation

    International Nuclear Information System (INIS)

    Prasad, Mahendra

    1981-01-01

    In order to understand and solve numerous problems related to sugar quality and its storage life, X-ray diffraction studies of sucrose and sucrose irradiated with γ-radiation have been made. It is observed that the interplanar spacing 'd' in irradiated sucrose is reduced indicating the partial damage of sucrose lattice. (author)

  6. Toward atomic resolution diffractive imaging of isolated molecules with x-ray free-electron lasers

    DEFF Research Database (Denmark)

    Stern, Stephan; Holmegaard, Lotte; Filsinger, Frank

    2014-01-01

    We give a detailed account of the theoretical analysis and the experimental results of an x-ray-diffraction experiment on quantum-state selected and strongly laser-aligned gas-phase ensembles of the prototypical large asymmetric rotor molecule 2,5-diiodobenzonitrile, performed at the Linac Cohere...

  7. Electron Paramagnetic Resonance and X-ray Diffraction of Boron- and Phosphorus-Doped Nanodiamonds

    Science.gov (United States)

    Binh, Nguyen Thi Thanh; Dolmatov, V. Yu.; Lapchuk, N. M.; Shymanski, V. I.

    2017-11-01

    Powders of boron- and phosphorus-doped detonation nanodiamonds and sintered pellets of non-doped nanodiamond powders were studied using electron paramagnetic resonance and x-ray diffraction. Doping of detonation nanodiamond crystals with boron and phosphorus was demonstrated to be possible. These methods could be used to diagnose diamond nanocrystals doped during shock-wave synthesis.

  8. Advances in thin film diffraction instrumentation by X-ray optics

    International Nuclear Information System (INIS)

    Haase, A.

    1996-01-01

    The structural characterisation of thin films requires a parallel X-ray beam of high intensity. Parallel beam geometry is commonly used in high resolution and single crystal experiments, but also in the field of X-ray diffraction for polycrystalline material (e.g. in phase, texture and stress analysis). For grazing incidence diffraction (GID), the use of small slits on the primary side and of long soller slits with a flat monochromator on the secondary side is standard. New optical elements have been introduced with polychromatic or monochromatic radiation. By means of different applications the results are compared with those of classical beam optics. X-ray fiber optics utilize total external reflection of X-rays on smooth surfaces. Effects of monochromatization are presented. In many fields of application, fiber optics may replace conventional collimators. The use of primary and secondary channel cut crystals can also produce a high parallel monochromatic X-ray beam. A parabolically bent graded multilayer produces a monochromatic parallel beam of high intensity. Compared with classical Bragg-Brentano (focussing) geometry, excellent results have been obtained, especially for samples with an irregular shape. In combination with a channel cut monochromator there is a substantial gain in intensity leading to an increase of the dynamic intensity range of rocking curves

  9. Advances in thin film diffraction instrumentation by X-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Haase, A [Rich. Seifert and Co., Analytical X-ray Systems, Ahrensburg (Germany)

    1996-09-01

    The structural characterisation of thin films requires a parallel X-ray beam of high intensity. Parallel beam geometry is commonly used in high resolution and single crystal experiments, but also in the field of X-ray diffraction for polycrystalline material (e.g. in phase, texture and stress analysis). For grazing incidence diffraction (GID), the use of small slits on the primary side and of long soller slits with a flat monochromator on the secondary side is standard. New optical elements have been introduced with polychromatic or monochromatic radiation. By means of different applications the results are compared with those of classical beam optics. X-ray fiber optics utilize total external reflection of X-rays on smooth surfaces. Effects of monochromatization are presented. In many fields of application, fiber optics may replace conventional collimators. The use of primary and secondary channel cut crystals can also produce a high parallel monochromatic X-ray beam. A parabolically bent graded multilayer produces a monochromatic parallel beam of high intensity. Compared with classical Bragg-Brentano (focussing) geometry, excellent results have been obtained, especially for samples with an irregular shape. In combination with a channel cut monochromator there is a substantial gain in intensity leading to an increase of the dynamic intensity range of rocking curves.

  10. X-ray diffraction analysis with diffractometer DRON-1

    International Nuclear Information System (INIS)

    Bochenin, V.I.

    1978-01-01

    Rapid methods of phase quantitative analysis of wolframite (FeMn)WO 4 and molybdenite MoS 2 in industrial materials using DRON-1 diffractometer are suggested. Diffractometer with spectrometric attachment was used for determination of (FeMn)WO 4 in industrial raw materials. Results of the above analysis have been compared with the data of chemical analysis, their good agreement has been shown. Time of wolframite determination in one sample is 8-10 min. Method of standard background with respect to absorption properties of medium has been developed for MoS 2 rapid determination in enriched molybdenum ore. Time of molybdenite determination in one sample is 3-4min., error is 4 % rel. in MoS 2 concentration range from 15.4 to 36.7 %

  11. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.

    1982-01-01

    The invention provides a method of producing visible difference images derived from an X-ray image of an anatomical subject, comprising the steps of directing X-rays through the anatomical subject for producing an image, converting the image into television fields comprising trains of on-going video signals, digitally storing and integrating the on-going video signals over a time interval corresponding to several successive television fields and thereby producing stored and integrated video signals, recovering the video signals from storage and producing integrated video signals, producing video difference signals by performing a subtraction between the integrated video signals and the on-going video signals outside the time interval, and converting the difference signals into visible television difference images representing on-going changes in the X-ray image

  12. New imaging technique based on diffraction of a focused x-ray beam

    Energy Technology Data Exchange (ETDEWEB)

    Kazimirov, A [Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, NY 14853 (United States); Kohn, V G [Russian Research Center ' Kurchatov Institute, 123182 Moscow (Russian Federation); Cai, Z-H [Advanced Photon Source, 9700 S. Cass Avenue, Argonne, IL 60439 (United States)], E-mail: ayk7@cornell.edu

    2009-01-07

    We present first experimental results from a new diffraction depth-sensitive imaging technique. It is based on the diffraction of a focused x-ray beam from a crystalline sample and recording the intensity pattern on a high-resolution CCD detector positioned at a focal plane. Structural non-uniformity inside the sample results in a region of enhanced intensity in the diffraction pattern. The technique was applied to study silicon-on-insulator thin layers of various thicknesses which revealed a complex strain profile within the layers. A circular Fresnel zone plate was used as a focusing optic. Incoherent diffuse scattering spreads out of the diffraction plane and results in intensity recorded outside of the focal spot providing a new approach to separately register x-rays scattered coherently and incoherently from the sample. (fast track communication)

  13. Simultaneous, single-pulse, synchrotron x-ray imaging and diffraction under gas gun loading

    Energy Technology Data Exchange (ETDEWEB)

    Fan, D.; Luo, S. N., E-mail: sluo@pims.ac.cn [The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610031 (China); Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu, Sichuan 610031 (China); Huang, J. W.; Zeng, X. L.; Li, Y.; E, J. C.; Huang, J. Y. [The Peac Institute of Multiscale Sciences, Chengdu, Sichuan 610031 (China); Sun, T.; Fezzaa, K. [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Wang, Z. [Physics Division P-25, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-05-15

    We develop a mini gas gun system for simultaneous, single-pulse, x-ray diffraction and imaging under high strain-rate loading at the beamline 32-ID of the Advanced Photon Source. In order to increase the reciprocal space covered by a small-area detector, a conventional target chamber is split into two chambers: a narrowed measurement chamber and a relief chamber. The gas gun impact is synchronized with synchrotron x-ray pulses and high-speed cameras. Depending on a camera’s capability, multiframe imaging and diffraction can be achieved. The proof-of-principle experiments are performed on single-crystal sapphire. The diffraction spots and images during impact are analyzed to quantify lattice deformation and fracture; fracture is dominated by splitting cracks followed by wing cracks, and diffraction peaks are broadened likely due to mosaic spread. Our results demonstrate the potential of such multiscale measurements for studying high strain-rate phenomena at dynamic extremes.

  14. X-ray diffraction of modified and graft polymerised cellulose fibres

    Energy Technology Data Exchange (ETDEWEB)

    Ouajai, S; Hodzic, A; Shanks, R A [RMIT University, Melbourne, VIC (Australia). Applied Chemistry

    2003-07-01

    Full text: The aim of this research is to modify natural cellulosic fibres in order to improve and increase consistency of their performance in biodegradable materials. Fibre modification consisted of solvent extraction and NaOH treatment in order to remove wax and lignin before grafting with acrylonitrile monomer. The mechanical properties, moisture regain and pore structures were investigated. Finally an analysis of crystalline structure was performed using quantitative FTIR, WAXD and SAXS to assess the relationship between structure and properties after modification. Materials: Hemp (Cannabis sativa), Australian Hemp Resource and Manufacture (AHRM) and Flax (Durafibre Grade 1, 95 % purity), Cargill, Canada. Pretreatments: Dewaxing by acetone extraction, alkalisation with NaOH solutions, grafting reaction with acrylonitrile and AIBN thermal initiator after absorption of the monomer. Surface and pore structure analysis using Micromeritics ASAP 2000 BET adsorption instrument, FTIR Perkin-Elmer 2000 spectrometer, wide angle X-ray diffraction, Bruker AXS D8, Ni-filtered CuK{alpha} radiation ({lambda} 0.1542 nm) at 40 kV and 35 mA. The diffractograms were recorded from 5 to 60 deg of 2 {theta} (Bragg angle) by a goniometer with a scintillation counter, scanning speed 0.02 deg/s and sampling rate of 2 data/s. The 2-D small-angle X-ray data was collected by Bruker AXS, Nanostar from 0.5 to 14 deg of 2{theta} (Bragg angle). Typical exposure time was 5 hours at 40 kV and 35 mA. Single fibre mechanical properties were carried out on a Rheometric DMTA IV at 0.03 mm/min. Moisture regain measurements were performed gravimetrically. The crystalline structure of the fibres were changed from cellulose I to cellulose II after NaOH treatment. The intensity of the 1431 cm{sup -1} band was reduced while the 898 cm{sup -1} band was increased and shifted to 893 cm{sup -1} with an increase of NaOH concentration. X-ray diffractograms of flax and hemp were obtained for each treatment

  15. X-ray diffraction of modified and graft polymerised cellulose fibres

    International Nuclear Information System (INIS)

    Ouajai, S.; Hodzic, A.; Shanks, R.A.

    2003-01-01

    Full text: The aim of this research is to modify natural cellulosic fibres in order to improve and increase consistency of their performance in biodegradable materials. Fibre modification consisted of solvent extraction and NaOH treatment in order to remove wax and lignin before grafting with acrylonitrile monomer. The mechanical properties, moisture regain and pore structures were investigated. Finally an analysis of crystalline structure was performed using quantitative FTIR, WAXD and SAXS to assess the relationship between structure and properties after modification. Materials: Hemp (Cannabis sativa), Australian Hemp Resource and Manufacture (AHRM) and Flax (Durafibre Grade 1, 95 % purity), Cargill, Canada. Pretreatments: Dewaxing by acetone extraction, alkalisation with NaOH solutions, grafting reaction with acrylonitrile and AIBN thermal initiator after absorption of the monomer. Surface and pore structure analysis using Micromeritics ASAP 2000 BET adsorption instrument, FTIR Perkin-Elmer 2000 spectrometer, wide angle X-ray diffraction, Bruker AXS D8, Ni-filtered CuKα radiation (λ 0.1542 nm) at 40 kV and 35 mA. The diffractograms were recorded from 5 to 60 deg of 2 θ (Bragg angle) by a goniometer with a scintillation counter, scanning speed 0.02 deg/s and sampling rate of 2 data/s. The 2-D small-angle X-ray data was collected by Bruker AXS, Nanostar from 0.5 to 14 deg of 2θ (Bragg angle). Typical exposure time was 5 hours at 40 kV and 35 mA. Single fibre mechanical properties were carried out on a Rheometric DMTA IV at 0.03 mm/min. Moisture regain measurements were performed gravimetrically. The crystalline structure of the fibres were changed from cellulose I to cellulose II after NaOH treatment. The intensity of the 1431 cm -1 band was reduced while the 898 cm -1 band was increased and shifted to 893 cm -1 with an increase of NaOH concentration. X-ray diffractograms of flax and hemp were obtained for each treatment. Untreated fibre shows the

  16. Characterization of breast tissue using energy-dispersive X-ray diffraction computed tomography

    International Nuclear Information System (INIS)

    Pani, S.; Cook, E.J.; Horrocks, J.A.; Jones, J.L.; Speller, R.D.

    2010-01-01

    A method for sample characterization using energy-dispersive X-ray diffraction computed tomography (EDXRDCT) is presented. The procedures for extracting diffraction patterns from the data and the corrections applied are discussed. The procedures were applied to the characterization of breast tissue samples, 6 mm in diameter. Comparison with histological sections of the samples confirmed the possibility of grouping the patterns into five families, corresponding to adipose tissue, fibrosis, poorly differentiated cancer, well differentiated cancer and benign tumour.

  17. Thermodynamic properties and low-temperature X-ray diffraction of vitamin B{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Knyazev, A.V., E-mail: knyazevav@gmail.com; Smirnova, N.N.; Shipilova, A.S.; Shushunov, A.N.; Gusarova, E.V; Knyazeva, S.S.

    2015-03-20

    Highlights: • Temperature dependence of heat capacity of vitamin B{sub 3} has been measured by precision adiabatic vacuum calorimetry. • The thermodynamic functions of the vitamin B{sub 3} have been determined for the range from T → 0 to 346 K. • The thermodynamic analysis of reactions involving nicotinic acid was made. • The low-temperature X-ray diffraction was used for the determination of coefficients of thermal expansion. - Abstract: In the present work temperature dependence of heat capacity of vitamin B{sub 3} (nicotinic acid) has been measured for the first time in the range from 5 to 346 K by precision adiabatic vacuum calorimetry. Based on the experimental data, the thermodynamic functions of the vitamin B{sub 3}, namely, the heat capacity, enthalpy H°(T) – H°(0), entropy S°(T) – S°(0) and Gibbs function G°(T) – H°(0) have been determined for the range from T → 0 to 343 K. The value of the fractal dimension D in the function of multifractal generalization of Debye’s theory of the heat capacity of solids was estimated and the character of heterodynamics of structure was detected. The thermodynamic parameters Δ{sub f}S°, Δ{sub f}G° at T = 298.15 K and p = 0.1 MPa have been calculated. The thermodynamic analysis of reactions involving nicotinic acid was made. The low-temperature X-ray diffraction was used for the determination of coefficients of thermal expansion.

  18. High-resolution X-ray diffraction with no sample preparation.

    Science.gov (United States)

    Hansford, G M; Turner, S M R; Degryse, P; Shortland, A J

    2017-07-01

    It is shown that energy-dispersive X-ray diffraction (EDXRD) implemented in a back-reflection geometry is extremely insensitive to sample morphology and positioning even in a high-resolution configuration. This technique allows high-quality X-ray diffraction analysis of samples that have not been prepared and is therefore completely non-destructive. The experimental technique was implemented on beamline B18 at the Diamond Light Source synchrotron in Oxfordshire, UK. The majority of the experiments in this study were performed with pre-characterized geological materials in order to elucidate the characteristics of this novel technique and to develop the analysis methods. Results are presented that demonstrate phase identification, the derivation of precise unit-cell parameters and extraction of microstructural information on unprepared rock samples and other sample types. A particular highlight was the identification of a specific polytype of a muscovite in an unprepared mica schist sample, avoiding the time-consuming and difficult preparation steps normally required to make this type of identification. The technique was also demonstrated in application to a small number of fossil and archaeological samples. Back-reflection EDXRD implemented in a high-resolution configuration shows great potential in the crystallographic analysis of cultural heritage artefacts for the purposes of scientific research such as provenancing, as well as contributing to the formulation of conservation strategies. Possibilities for moving the technique from the synchrotron into museums are discussed. The avoidance of the need to extract samples from high-value and rare objects is a highly significant advantage, applicable also in other potential research areas such as palaeontology, and the study of meteorites and planetary materials brought to Earth by sample-return missions.

  19. X-ray diffraction study of microstructural changes during fatigue damage initiation in steel pipes

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, B., E-mail: bianca@lts.coppe.ufrj.br [Laboratory of Mechanics of Lille (LML), UMR CNRS 8107, University of Lille 1, Boulevard Paul Langevin, Cite Scientifique, 59655 Villeneuve d' Ascq (France); Lesage, J. [Laboratory of Mechanics of Lille (LML), UMR CNRS 8107, University of Lille 1, Boulevard Paul Langevin, Cite Scientifique, 59655 Villeneuve d' Ascq (France); Pasqualino, I. [Subsea Technology Laboratory (LTS), Ocean Engineering Department, COPPE/Federal University of Rio de Janeiro, PO Box 68508, Cidade Universitaria, CEP 21945-970, Rio de Janeiro/RJ (Brazil); Benseddiq, N. [Laboratory of Mechanics of Lille (LML), UMR CNRS 8107, University of Lille 1, Boulevard Paul Langevin, Cite Scientifique, 59655 Villeneuve d' Ascq (France); Bemporad, E. [Interdepartmental Laboratory of Electron Microscopy (LIME), University of Rome TRE, Via Della Vasca Navale 79, 00146 Rome (Italy)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer In this work we study the fatigue damage evolution in an API 5L X60 steel. Black-Right-Pointing-Pointer Microstructural changes and residual stresses are evaluated during fatigue tests. Black-Right-Pointing-Pointer Microdeformations and macro residual stresses are estimated by X-ray diffraction. Black-Right-Pointing-Pointer Results are discussed in view of an indicator of fatigue damage initiation. Black-Right-Pointing-Pointer This indicator could allow the prediction of residual life before macrocracking. - Abstract: Steel pipes used in the oil and gas industry undergo the action of cyclic loads that can cause their failure by fatigue. A consistent evaluation of the fatigue damage during the initiation phase should fundamentally be based on a nanoscale approach, i.e., at the scale of the dislocation network, in order to take into account the micromechanisms of fatigue damage that precede macrocrack initiation and propagation until the final fracture. In this work, microstructural changes related to fatigue damage initiation are investigated in the API 5L X60 grade steel, used in pipe manufacturing. Microdeformations and macro residual stress are evaluated using X-ray diffraction in real time during alternating bending fatigue tests performed on samples cut off from an X60 steel pipe. The aim of this ongoing work is to provide ground for further development of an indicator of fatigue damage initiation in X60 steel. This damage indicator could allow a good residual life prediction of steel pipes previously submitted to fatigue loading, before macroscopic cracking, and help to increase the reliability of these structures.

  20. Noise reduction in real time x-ray images

    International Nuclear Information System (INIS)

    Tsuda, Motohisa; Kimura, Yutaro

    1986-01-01

    The signal-to-noise ratio of real-time digital X-ray imaging systems consisting of an X-ray image intensifer-television chain was investigated while concentrating on the effect of the X-ray quantum nature. Along with conventional signal accumulation, logarithmic conversion and subtraction, a new technique called the peak hold method is introduced. Theoretical and simulational studies were made with practical parameters. Theory and simulation showed good agreement. An accumulation of signal is most effective for improving the signal-to-noise ratio; the peak-hold method comes next. The peak hold method, however, offers a new image-display mode. Moreover, this method is superior to signal accumulation for specific conditions. (author)

  1. Phases quantification in titanium oxides by means of X-ray diffraction

    International Nuclear Information System (INIS)

    Macias B, L.R.; Garcia C, R.M.; Ita T, A. de; Chavez R, A.

    2001-01-01

    In this work two phases of titanium oxides are quantified which belong to the same crystalline system and by means of a computer program named Quanto created by the first author, contains the information for calculating the absorption coefficients, it can be quantified phases having one of the pure phases and the problem samples. In order to perform this work different mixtures of different titanium oxides were prepared measuring by means of the X-ray diffraction technique in the Siemens X-ray diffractometer of ININ which were processed with the Peakfit package and also they were evaluated by means of the computer program with the necessary information finding acceptable results. (Author)

  2. X-Ray diffraction studies of silicon implanted with high energy ions

    International Nuclear Information System (INIS)

    Wieteska, K.; Wierzchowski, W.; Graeff, W.

    1998-01-01

    The character of lattice deformation in silicon implanted with high energy alpha-particles and protons was studied using a number of X-ray methods. The experiments included double-crystal spectrometer method as well as single crystal section and projection topography realised both with conventional and synchrotron X-ray sources. All observed diffraction patterns were reasonably explainable assuming the lattice parameter distribution proportional to the vacancy-interstitial distribution coming from the Biersack-ziegler theory. The theoretical rocking curves and distribution in back-reflection double-crystal and section topographs well corresponding to the experimental results were calculated using numerical integration of the takagi-taupin equations

  3. Quantitative X-ray diffraction analysis of alumina, silicon carbide and zirconium carbide in ceramic composites

    International Nuclear Information System (INIS)

    Veiga, Sonia M.B.; Bressiani, Jose Carlos; Veiga, Marcello M.; Chaklader, Asoke C.D.

    1995-01-01

    The x-ray diffraction technique has been successfully applied to determine the phases formed in a carbo thermal synthesis of ceramic composites (Al 2 O 3 -Si C and Al 2 O 3 -Si C-Zr C) using kaolinite, cyanite and zircon as precursors. The powder method using fluorite as internal standard has shown reliable results to estimate accurately phases in composites (relative error as low as 5%). In addition, quantitative X-ray analysis allows an indirect evaluation of Si O (gas) losses from the system during the carbo thermal reaction. (author)

  4. Reflection-mode x-ray powder diffraction cell for in situ studies of electrochemical reactions

    International Nuclear Information System (INIS)

    Roberts, G.A.; Stewart, K.D.

    2004-01-01

    The design and operation of an electrochemical cell for reflection-mode powder x-ray diffraction experiments are discussed. The cell is designed for the study of electrodes that are used in rechargeable lithium batteries. It is designed for assembly in a glove box so that air-sensitive materials, such as lithium foil electrodes and carbonate-based electrolytes with lithium salts, can be used. The cell uses a beryllium window for x-ray transmission and electrical contact. A simple mechanism for compressing the electrodes is included in the design. Sample results for the cell are shown with a Cu Kα source and a position-sensitive detector

  5. Preliminary study of determination of UO2 grain size using X-ray diffraction method

    International Nuclear Information System (INIS)

    Mulyana, T.; Sambodo, G. D.; Juanda, D.; Fatchatul, B.

    1998-01-01

    The determination of UO 2 grain size has accomplished using x-ray diffraction method. The UO 2 powder is obtained from sol-gel process. A copper target as radiation source in the x-ray diffractometer was used in this experiment with CμKα characteristic wavelength 1.54433 Angstrom. The result indicate that the UO 2 mean grain size on presintered (temperature 800 o C) has the value 456.8500 Angstrom and the UO 2 mean grain size on sintered (temperature 1700 o C) has value 651.4934 Angstrom

  6. X-ray detectors for diffraction studies and their use with synchrotron radiation

    International Nuclear Information System (INIS)

    Milch, J.

    1976-02-01

    All techniques for X-ray diffraction studies on biological materials exhibit certain limitations. The characteristics of several X-ray detection systems, namely film, multiwire proportional counter and image intensified TV, are discussed and compared for application to specific biological studies. For the high count-rate situation existing at a synchrotron, it is shown that film is a good choice, but that the image intensified TV exhibits significant advantages. The details of such a system now being used at Princeton with a low intensity source are given and current results presented

  7. Surface quality inspection of PbWO4 crystals by grazing incidence X-ray diffraction

    International Nuclear Information System (INIS)

    Mengucci, P.; Di Cristoforo, A.; Lebeau, M.; Majni, G.; Paone, N.; Pietroni, P.; Rinaldi, D.

    2005-01-01

    High-quality scintillating crystals are required for applications in radiographic systems and high-energy physics detectors to achieve the specified optical properties. In order to study the state of the single crystals surface we propose the use of the grazing incidence X-ray diffraction (GID) technique. This technique allows performing a depth profiling of the sample by changing the incidence angle of the X-ray beam with respect to the sample surface. In this work, two samples of a large PbWO 4 (PWO) single crystal exhibiting different surface roughness values have been studied. Results have shown that GID is a suitable technique for surface quality inspection

  8. X-ray diffraction in laser-irradiated epsomite crystals grown in presence of borax

    International Nuclear Information System (INIS)

    Zaitseva, E.V.; Portnov, V.N.; Faddeev, M.A.; Chuprunov, E.V.

    1997-01-01

    Relative changes in the intensities ΔI/I of the (220) and (440) X-ray diffraction reflection during laser irradiation of epsomite (MgSO 2 ·7H 2 O) crystals grown from an aqueous solution in the presence of borax (Na 2 B 4 O 7 ·10H 2 O) were measured using the CoK α , CuK α , MoK α radiations. The intensities measured depend on the real crystal structure dependent on the borax content in the solution. The dependence of ΔI/I is studied as a function of borax in the solution and X-ray-radiation wavelength

  9. Investigation of surface residual stress profile on martensitic stainless steel weldment with X-ray diffraction

    Directory of Open Access Journals (Sweden)

    I.I. Ahmed

    2018-04-01

    Full Text Available The development of residual stresses during fabrication is inevitable and often neglected with dire consequences during the service life of the fabricated components. In this work, the surface residual stress profile following the martensitic stainless steel (MSS pipe welding was investigated with X-ray diffraction technique. The results revealed the presence of residual stresses equilibrated across the weldment zones. Tensile residual stress observed in weld metal was balanced by compressive residual stresses in the parent material on the opposing sides of weld metal. Keywords: Residual stress, Weld, Stainless steel, X-ray, HAZ

  10. Qualitative and quantitative determination of sediments phases in Chillon River by x-ray diffraction

    International Nuclear Information System (INIS)

    Miramira Tipula, Biviano; Zeballos Velasquez, Elvira; Chui Betancur, Heber; Valencia Salazar, Edilberto; Huaypar Vasquez, Yesena; Olivera de Lescano, Paula

    2008-01-01

    With this paper, we pretend to contribute with the recovery of Chillon River from a characterization of sediments. The objectives are the identification of pollution places along the bed of the Chillon River, from the Canta Province to Lima Province (Comas) and the determination of the preponderant factors of pollution. The qualitative and semi-quantitative determination of the sediments components have been carried out using the x-ray diffraction and x-ray fluorescence techniques, both of them will allow us to identify the pollute elements, for example the lead level in the Chillon River. (author)

  11. A sample holder for in-house X-ray powder diffraction studies of protein powders

    DEFF Research Database (Denmark)

    Frankær, Christian Grundahl; Harris, Pernille; Ståhl, Kenny

    2011-01-01

    A sample holder for handling samples of protein for in-house X-ray powder diffraction (XRPD) analysis has been made and tested on lysozyme. The use of an integrated pinhole reduced the background, and good signal-to-noise ratios were obtained from only 7 l of sample, corresponding to approximatel...... 2-3 mg of dry protein. The sample holder is further adaptable to X-ray absorption spectroscopy (XAS) measurements. Both XRPD and XAS at the Zn K-edge were tested with hexameric Zn insulin....

  12. Quantum Crystallography: Density Matrix-Density Functional Theory and the X-Ray Diffraction Experiment

    Science.gov (United States)

    Soirat, Arnaud J. A.

    Density Matrix Theory is a Quantum Mechanical formalism in which the wavefunction is eliminated and its role taken over by reduced density matrices. The interest of this is that, it allows one, in principle, to calculate any electronic property of a physical system, without having to solve the Schrodinger equation, using only two entities much simpler than an N-body wavefunction: first and second -order reduced density matrices. In practice, though, this very promising possibility faces the tremendous theoretical problem of N-representability, which has been solved for the former, but, until now, voids any hope of theoretically determining the latter. However, it has been shown that single determinant reduced density matrices of any order may be recovered from coherent X-ray diffraction data, if one provides a proper Quantum Mechanical description of the Crystallography experiment. A deeper investigation of this method is the purpose of this work, where we, first, further study the calculation of X-ray reduced density matrices N-representable by a single Slater determinant. In this context, we independently derive necessary and sufficient conditions for the uniqueness of the method. We then show how to account for electron correlation in this model. For the first time, indeed, we derive highly accurate, yet practical, density matrices approximately N-representable by correlated-determinant wavefunctions. The interest of such a result lies in the Quantum Mechanical validity of these density matrices, their property of being entirely obtainable from X-ray coherent diffraction data, their very high accuracy conferred by this known property of the N-representing wavefunction, as well as their definition as explicit functionals of the density. All of these properties are finally used in both a theoretical and a numerical application: in the former, we show that these density matrices may be used in the context of Density Functional Theory to highly accurately determine

  13. X-ray time and spectral variability as probes of ultraluminous x-ray sources

    Science.gov (United States)

    Pasham, Dheeraj Ranga Reddy

    A long-standing debate in the field of ultraluminous X-ray sources (ULXs: luminosities > 3x1039 ergs s-1) is whether these objects are powered by stellar-mass black holes (mass range of 3-25 solar masses) undergoing hyper-accretion/emission or if they host the long-sought after class of intermediate-mass black holes (mass range of a few 100-1000 solar masses) accreting material at sub-Eddington rates. We present X-ray time and energy spectral variability studies of ULXs in order to understand their physical environments and accurately weigh their compact objects. A sample of ULXs exhibit quasi-periodic oscillations (QPOs) with centroid frequencies in the range of 10-200 mHz. The nature of the power density spectra (PDS) of these sources is qualitatively similar to stellar-mass black holes when they exhibit the so-called type-C low-frequency QPOs (frequency range of 0.2-15 Hz). However, the crucial difference is that the characteristic frequencies within the PDS of ULXs, viz., the break frequencies and the centroid frequencies of the QPOs, are scaled down by a factor of approximately 10-100 compared to stellar-mass black holes. It has thus been argued that the ULX mHz QPOs are the type-C low-frequency QPO analogs of stellar-mass black holes and that the observed difference in the frequencies (a fewx0.01 Hz compared with a few Hz) is due to the presence of intermediate-mass black holes ( MULX = (QPOstellar-mass black hole }/QPOULX)xM stellar-mass black hole, where M and QPO are the mass and the QPO frequency, respectively) within these ULXs. We analyzed all the archival XMM-Newton X-ray data of ULXs NGC 5408 X-1 and M82 X-1 in order to test the hypothesis that the ULX mHz QPOs are the type-C analogs by searching for a correlation between the mHz QPO frequency and the energy spectral power-law index as type-C QPOs show such a dependence. From our multi-epoch timing and spectral analysis of ULXs NGC 5408 X-1 and M82 X-1, we found that the mHz QPOs of these sources vary

  14. Non-destructive analysis of micro texture and grain boundary character from X-ray diffraction contrast tomography

    DEFF Research Database (Denmark)

    King, A.; Herbig, M.; Ludwig, W.

    2010-01-01

    Recent advances in synchrotron based X-ray imaging and diffraction techniques offer interesting new possibilities for mapping 3D grain shapes and crystallographic orientations in different classes of polycrystalline materials. X-ray diffraction contrast tomography (DCT) is a monochromatic beam...... imaging technique combining the principles of X-ray micro-tomography and three-dimensional X-ray diffraction microscopy (3DXRD). DCT provides simultaneous access to 3D grain shape, crystallographic orientation and attenuation coefficient distribution at the micrometer length scale. The microtexture...

  15. Moessbauer spectroscopy and X-ray diffraction study of 304 L stainless steel thin films

    International Nuclear Information System (INIS)

    Boubeker, B.; Eymery, J.P.; Goudeau, P.; Sayouty, E.H.

    1994-01-01

    304 L stainless steel films (SS) were elaborated using an ion-beam sputtering technique. The target material was a sheet of commercial grade 304 L SS. The starting material was first analysed by both conversion electron Moessbauer spectroscopy (CEMS) and X-ray diffraction. The nonmagnetic state and f.c.c. structure of this material were confirmed. The films were deposited on various substrates with thicknesses in the 175-800 nm range. The films are found to have both b.c.c. structure and ferromagnetic character. X-ray diffraction technique was also used in order to determine the residual stresses developed during the deposition process. The second stage of the work is devoted to the evolution of the film structure as a function of annealing treatments. So isochronal and isothermal kinetics at temperatures higher than 913 K have allowed to follow the alpha --> gamma phase transformation using X-ray diffraction and CEMS technique.The X-ray diffractograms reveal the existence of both b.c.c. and f.c.c. phases. Similar results can be deduced from Moessbauer spectra due to the single line coming from the non-magnetic phase and the sextet coming from the ferromagnetic phase. In addition the CEMS spectra reveal that the ferromagnetic component is split into two parts which indicates the existence of two iron sites. 1 fig., 4 refs.(author)

  16. Vibrational spectra, powder X-ray diffractions and physical properties of cyanide complexes with 1-ethylimidazole

    Science.gov (United States)

    Kürkçüoğlu, Güneş Süheyla; Kiraz, Fulya Çetinkaya; Sayın, Elvan

    2015-10-01

    The heteronuclear tetracyanonickelate(II) complexes of the type [M(etim)Ni(CN)4]n (hereafter, abbreviated as M-Ni-etim, M = Mn(II), Fe(II) or Co(II); etim = 1-ethylimidazole, C5H8N2) were prepared in powder form and characterized by FT-IR and Raman spectroscopy, powder X-ray diffraction (PXRD), thermal (TG; DTG and DTA), and elemental analysis techniques. The structures of these complexes were elucidated using vibrational spectra and powder X-ray diffraction patterns with the peak assignment to provide a better understanding of the structures. It is shown that the spectra are consistent with a proposed crystal structure for these compounds derived from powder X-ray diffraction measurements. Vibrational spectra of the complexes were presented and discussed with respect to the internal modes of both the etim and the cyanide ligands. The C, H and N analyses were carried out for all the complexes. Thermal behaviors of these complexes were followed using TG, DTG and DTA curves in the temperature range 30-700 °C in the static air atmosphere. The FT-IR, Raman spectra, thermal and powder X-ray analyses revealed no significant differences between the single crystal and powder forms. Additionally, electrical and magnetic properties of the complexes were investigated. The FT-IR and Raman spectroscopy, PXRD, thermal and elemental analyses results propose that these complexes are similar in structure to the Hofmann-type complexes.

  17. X-ray diffraction diagnostic design for the National Ignition Facility

    Science.gov (United States)

    Ahmed, Maryum F.; House, Allen; Smith, R. F.; Ayers, Jay; Lamb, Zachary S.; Swift, David W.

    2013-09-01

    This paper describes the design considerations for Target Diffraction In-Situ (TARDIS), an x-ray diffraction diagnostic at the National Ignition Facility. A crystal sample is ramp-compressed to peak pressures between 10 and 30 Mbar and, during a pressure hold period, is probed with quasi-monochromatic x-rays emanating from a backlighter source foil. The crystal spectrography diffraction lines are recorded onto image plates. The crystal sample, filter, and image plates are packaged into one assembly, allowing for accurate and repeatable target to image plate registration. Unconverted laser light impinges upon the device, generating debris, the effects of which have been mitigated. Dimpled blast shields, high strength steel alloy, and high-z tungsten are used to shield and protect the image plates. A tapered opening was designed to provide adequate thickness of shielding materials without blocking the drive beams or x-ray source from reaching the crystal target. The high strength steel unit serves as a mount for the crystal target and x-ray source foil. A tungsten body contains the imaging components. Inside this sub-assembly, there are three image plates: a 160 degree field of view curved plate directly opposite the target opening and two flat plates for the top and bottom. A polycarbonate frame, coated with the appropriate filter material and embedded with registration features for image plate location, is inserted into the diagnostic body. The target assembly is metrologized and then the diagnostic assembly is attached.

  18. Rapid, low dose X-ray diffractive imaging of the malaria parasite Plasmodium falciparum

    International Nuclear Information System (INIS)

    Jones, Michael W.M.; Dearnley, Megan K.; Riessen, Grant A. van; Abbey, Brian; Putkunz, Corey T.; Junker, Mark D.; Vine, David J.; McNulty, Ian; Nugent, Keith A.; Peele, Andrew G.; Tilley, Leann

    2014-01-01

    Phase-diverse X-ray coherent diffractive imaging (CDI) provides a route to high sensitivity and spatial resolution with moderate radiation dose. It also provides a robust solution to the well-known phase-problem, making on-line image reconstruction feasible. Here we apply phase-diverse CDI to a cellular sample, obtaining images of an erythrocyte infected by the sexual stage of the malaria parasite, Plasmodium falciparum, with a radiation dose significantly lower than the lowest dose previously reported for cellular imaging using CDI. The high sensitivity and resolution allow key biological features to be identified within intact cells, providing complementary information to optical and electron microscopy. This high throughput method could be used for fast tomographic imaging, or to generate multiple replicates in two-dimensions of hydrated biological systems without freezing or fixing. This work demonstrates that phase-diverse CDI is a valuable complementary imaging method for the biological sciences and ready for immediate application. - Highlights: • Phase-diverse coherent X-ray diffraction microscopy provides high-resolution and high-contrast images of intact biological samples. • Rapid nanoscale resolution imaging is demonstrated at orders of magnitude lower dose than previously possible. • Phase-diverse coherent X-ray diffraction microscopy is a robust technique for rapid, quantitative, and correlative X-ray phase imaging

  19. Capillary based Li-air batteries for in situ synchrotron X-ray powder diffraction studies

    DEFF Research Database (Denmark)

    Storm, Mie Møller; Johnsen, Rune E.; Younesi, Reza

    2015-01-01

    For Li-air batteries to reach their full potential as energy storage system, a complete understanding of the conditions and reactions in the battery during operation is needed. To follow the reactions in situ a capillary-based Li-O2 battery has been developed for synchrotron-based in situ X......-ray powder diffraction (XRPD). In this article, we present the results for the analysis of 1st and 2nd deep discharge and charge for a cathode being cycled between 2 and 4.6 V. The crystalline precipitation of Li2O2 only is observed in the capillary battery. However, there are indications of side reactions...... of constant exposure of X-ray radiation to the electrolyte and cathode during charge of the battery was also investigated. X-ray exposure during charge leads to changes in the development of the intensity and the FWHM of the Li2O2 diffraction peaks. The X-ray diffraction results are supported by ex situ X...

  20. Quantitative determination of mineral composition by powder X-ray diffraction

    International Nuclear Information System (INIS)

    Pawloski, G.A.

    1986-01-01

    A method is described of quantitatively determining the mineral composition in a test sample containing a number (m) of minerals from a group (n) of known minerals, wherein n=13, where mless than or equal ton, by x-ray diffraction, comprising: determining from standard samples of the known minerals a set of (n) standard coefficients K/sub j/=(X/sub j//X/sub l/)(I/sub l//I/sub j/) for each mineral (j=2...n) in the group of known minerals (j=2...n) relative to one mineral (l) in the group selected as a reference mineral, where X is the weight fraction of the mineral in a standard sample, and I is the x-ray integrated intensity peak of each mineral obtained from the standard sample; obtaining an x-ray diffraction pattern of the test sample; identifying each of the (m) minerals in the test sample for the x-ray diffraction pattern; calculating the relative weight fractions X/sub j//X/sub l/ for each mineral (j=2...m) compared to the reference mineral (l) from the ratio of the measured highest integrated intensity peak I/sub j/ of each mineral in the test sample to the measured highest integrated intensity peak I/sub l/ of the reference mineral in the test sample, and from the previously determined standard coefficients, X/sub j//X/sub l/=K/sub j/(I/sub j//I/sub l/

  1. Rapid, low dose X-ray diffractive imaging of the malaria parasite Plasmodium falciparum

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Michael W.M., E-mail: michael.jones@latrobe.edu.au [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Dearnley, Megan K. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Biochemistry and Molecular Biology, Bio21 Institute, The University of Melbourne, Victoria 3010 (Australia); Riessen, Grant A. van [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Abbey, Brian [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Melbourne Centre for Nanofabrication, Victoria 3168 (Australia); Putkunz, Corey T. [ARC Centre of Excellence for Coherent X-Ray Science, School of Physics, The University of Melbourne, Victoria 3010 (Australia); Junker, Mark D. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Vine, David J. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); McNulty, Ian [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Centre for Nanoscale Materials, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Nugent, Keith A. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Peele, Andrew G. [ARC Centre of Excellence for Coherent X-Ray Science, Department of Physics, La Trobe University, Victoria 3086 (Australia); Australian Synchrotron, 800 Blackburn Road, Clayton 3168 (Australia); Tilley, Leann [ARC Centre of Excellence for Coherent X-Ray Science, Department of Biochemistry and Molecular Biology, Bio21 Institute, The University of Melbourne, Victoria 3010 (Australia)

    2014-08-01

    Phase-diverse X-ray coherent diffractive imaging (CDI) provides a route to high sensitivity and spatial resolution with moderate radiation dose. It also provides a robust solution to the well-known phase-problem, making on-line image reconstruction feasible. Here we apply phase-diverse CDI to a cellular sample, obtaining images of an erythrocyte infected by the sexual stage of the malaria parasite, Plasmodium falciparum, with a radiation dose significantly lower than the lowest dose previously reported for cellular imaging using CDI. The high sensitivity and resolution allow key biological features to be identified within intact cells, providing complementary information to optical and electron microscopy. This high throughput method could be used for fast tomographic imaging, or to generate multiple replicates in two-dimensions of hydrated biological systems without freezing or fixing. This work demonstrates that phase-diverse CDI is a valuable complementary imaging method for the biological sciences and ready for immediate application. - Highlights: • Phase-diverse coherent X-ray diffraction microscopy provides high-resolution and high-contrast images of intact biological samples. • Rapid nanoscale resolution imaging is demonstrated at orders of magnitude lower dose than previously possible. • Phase-diverse coherent X-ray diffraction microscopy is a robust technique for rapid, quantitative, and correlative X-ray phase imaging.

  2. X-ray diffraction characteristics of curved monochromators for sychrotron radiation

    International Nuclear Information System (INIS)

    Boeuf, A.; Rustichelli, F.; Mazkedian, S.; Puliti, P.; Melone, S.

    1978-01-01

    A theoretical study is presented concerning the diffraction characteristics of curved monochromators for X-ray synchrotron radiation used at the laboratories of Hamburg, Orsay and Stanford. The investigation was performed by extending to the X-ray case a simple model recently developed and fruitfully employed to describe the neutron diffraction properties of curved monochromators. Several diffraction patterns were obtained corresponding to different monochromator materials (Ge, Si) used by the different laboratories, for different reflecting planes (111), (220), asymmetry angles, X-ray wave-lengths (Mo Kα, Cu Kα, Cr Kα) and curvature radii. The results are discussed in physical terms and their implications on the design of curved monochromators for synchrotron radiation are presented. In particular, the study shows that all the monochromators used in the different laboratories should behave practically as perfect crystals and therefore should have a very low integrated reflectivity corresponding to an optimized wavelength passband Δlambda/lambda approximately 10 -4 . The gain that can be obtained by increasing the curvature, by introducing a gradient in the lattice spacing or by any other kind of imperfection is quite limited and much lower than the desirable value. The adopted model can help in obtaining a possible moderate gain in intensity by also taking into consideration other parameters, such as crystal material, reflecting plane, asymmetry of the reflection and X-ray wavelength. (Auth.)

  3. Line x-ray source for diffraction enhanced imaging in clinical and industrial applications

    Science.gov (United States)

    Wang, Xiaoqin

    Mammography is one type of imaging modalities that uses a low-dose x-ray or other radiation sources for examination of breasts. It plays a central role in early detection of breast cancers. The material similarity of tumor-cell and health cell, breast implants surgery and other factors, make the breast cancers hard to visualize and detect. Diffraction enhanced imaging (DEI), first proposed and investigated by D. Chapman is a new x-ray radiographic imaging modality using monochromatic x-rays from a synchrotron source, which produced images of thick absorbing objects that are almost completely free of scatter. It shows dramatically improved contrast over standard imaging when applied to the same phantom. The contrast is based not only on attenuation but also on the refraction and diffraction properties of the sample. This imaging method may improve image quality of mammography, other medical applications, industrial radiography for non-destructive testing and x-ray computed tomography. However, the size, and cost, of a synchrotron source limits the application of the new modality to be applicable at clinical levels. This research investigates the feasibility of a designed line x-ray source to produce intensity compatible to synchrotron sources. It is composed of a 2-cm in length tungsten filament, installed on a carbon steel filament cup (backing plate), as the cathode and a stationary oxygen-free copper anode with molybdenum coating on the front surface serves as the target. Characteristic properties of the line x-ray source were computationally studied and the prototype was experimentally investigated. SIMIION code was used to computationally study the electron trajectories emanating from the filament towards the molybdenum target. A Faraday cup on the prototype device, proof-of-principle, was used to measure the distribution of electrons on the target, which compares favorably to computational results. The intensities of characteristic x-ray for molybdenum

  4. Optimizing Monocapillary Optics for Synchrotron X-ray Diffraction, Fluorescence Imaging, and Spectroscopy Applications

    International Nuclear Information System (INIS)

    Bilderback, Donald H.; Kazimirov, Alexander; Gillilan, Richard; Cornaby, Sterling; Woll, Arthur; Zha, Chang-Sheng; Huang Rong

    2007-01-01

    A number of synchrotron x-ray applications such as powder diffraction in diamond anvil cells, microbeam protein crystallography, x-ray fluorescence imaging, etc. can benefit from using hollow glass monocapillary optics to improve the flux per square micron on a sample. We currently draw glass tubing into the desired elliptical shape so that only one-bounce under total reflection conditions is needed to bring the x-ray beam to a focus at a 25 to 50 mm distance beyond the capillary tip. For modest focal spot sizes of 10 to 20 microns, we can increase the intensity per square micron by factors of 10 to 1000. We show some of the results obtained at CHESS and Hasylab with capillaries focusing 5 to 40 keV radiation, their properties, and how even better the experimental results could be if more ideal capillaries were fabricated in the future

  5. Simultaneous Femtosecond X-ray Spectroscopy and Diffraction of Photosystem II at Room Temperature

    Science.gov (United States)

    Kern, Jan; Alonso-Mori, Roberto; Tran, Rosalie; Hattne, Johan; Gildea, Richard J.; Echols, Nathaniel; Glöckner, Carina; Hellmich, Julia; Laksmono, Hartawan; Sierra, Raymond G.; Lassalle-Kaiser, Benedikt; Koroidov, Sergey; Lampe, Alyssa; Han, Guangye; Gul, Sheraz; DiFiore, Dörte; Milathianaki, Despina; Fry, Alan R.; Miahnahri, Alan; Schafer, Donald W.; Messerschmidt, Marc; Seibert, M. Marvin; Koglin, Jason E.; Sokaras, Dimosthenis; Weng, Tsu-Chien; Sellberg, Jonas; Latimer, Matthew J.; Grosse-Kunstleve, Ralf W.; Zwart, Petrus H.; White, William E.; Glatzel, Pieter; Adams, Paul D.; Bogan, Michael J.; Williams, Garth J.; Boutet, Sébastien; Messinger, Johannes; Zouni, Athina; Sauter, Nicholas K.; Yachandra, Vittal K.; Bergmann, Uwe; Yano, Junko

    2013-01-01

    Intense femtosecond X-ray pulses produced at the Linac Coherent Light Source (LCLS) were used for simultaneous X-ray diffraction (XRD) and X-ray emission spectroscopy (XES) of microcrystals of Photosystem II (PS II) at room temperature. This method probes the overall protein structure and the electronic structure of the Mn4CaO5 cluster in the oxygen-evolving complex of PS II. XRD data are presented from both the dark state (S1) and the first illuminated state (S2) of PS II. Our simultaneous XRD/XES study shows that the PS II crystals are intact during our measurements at the LCLS, not only with respect to the structure of PS II, but also with regard to the electronic structure of the highly radiation sensitive Mn4CaO5 cluster, opening new directions for future dynamics studies. PMID:23413188

  6. X-ray laser diffraction for structure determination of the rhodopsin-arrestin complex

    Science.gov (United States)

    Zhou, X. Edward; Gao, Xiang; Barty, Anton; Kang, Yanyong; He, Yuanzheng; Liu, Wei; Ishchenko, Andrii; White, Thomas A.; Yefanov, Oleksandr; Han, Gye Won; Xu, Qingping; de Waal, Parker W.; Suino-Powell, Kelly M.; Boutet, Sébastien; Williams, Garth J.; Wang, Meitian; Li, Dianfan; Caffrey, Martin; Chapman, Henry N.; Spence, John C. H.; Fromme, Petra; Weierstall, Uwe; Stevens, Raymond C.; Cherezov, Vadim; Melcher, Karsten; Xu, H. Eric

    2016-04-01

    Serial femtosecond X-ray crystallography (SFX) using an X-ray free electron laser (XFEL) is a recent advancement in structural biology for solving crystal structures of challenging membrane proteins, including G-protein coupled receptors (GPCRs), which often only produce microcrystals. An XFEL delivers highly intense X-ray pulses of femtosecond duration short enough to enable the collection of single diffraction images before significant radiation damage to crystals sets in. Here we report the deposition of the XFEL data and provide further details on crystallization, XFEL data collection and analysis, structure determination, and the validation of the structural model. The rhodopsin-arrestin crystal structure solved with SFX represents the first near-atomic resolution structure of a GPCR-arrestin complex, provides structural insights into understanding of arrestin-mediated GPCR signaling, and demonstrates the great potential of this SFX-XFEL technology for accelerating crystal structure determination of challenging proteins and protein complexes.

  7. Collagen imaged by Coherent X-ray Diffraction: towards a complementary tool to conventional scanning SAXS

    International Nuclear Information System (INIS)

    Berenguer de la Cuesta, Felisa; Bean, Richard J; Bozec, Laurent; Robinson, Ian K; McCallion, Catriona; Wallace, Kris; Hiller, Jen C; Terrill, Nicholas J

    2010-01-01

    Third generation x-ray sources offer unique possibilities for exploiting coherence in the study of materials. New insights in the structure and dynamics of soft condensed matter and biological samples can be obtained by coherent x-ray diffraction (CXD). However, the experimental procedures for applying these methods to collagen tissues are still under development. We present here an investigation for the optimal procedure in order to obtain high quality CXD data from collagen tissues. Sample handling and preparation and adequate coherence defining apertures are among the more relevant factors to take into account. The impact of the results is also discussed, in particular in comparison with the information that can be extracted from conventional scanning small angle x-ray scattering (SAXS). Images of collagen tissues obtained by CXD reconstructions will give additional information about the local structure with higher resolution and will complement scanning SAXS images.

  8. Collagen imaged by Coherent X-ray Diffraction: towards a complementary tool to conventional scanning SAXS

    Energy Technology Data Exchange (ETDEWEB)

    Berenguer de la Cuesta, Felisa; Bean, Richard J; Bozec, Laurent; Robinson, Ian K [London Centre for Nanotechnology (LCN), University College London (UCL), London WC1H 0AH (United Kingdom); McCallion, Catriona; Wallace, Kris [Department of Physics and Astronomy, University College London (UCL), London WC1E 6BT (United Kingdom); Hiller, Jen C; Terrill, Nicholas J, E-mail: f.berenguer@ucl.ac.u [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2010-10-01

    Third generation x-ray sources offer unique possibilities for exploiting coherence in the study of materials. New insights in the structure and dynamics of soft condensed matter and biological samples can be obtained by coherent x-ray diffraction (CXD). However, the experimental procedures for applying these methods to collagen tissues are still under development. We present here an investigation for the optimal procedure in order to obtain high quality CXD data from collagen tissues. Sample handling and preparation and adequate coherence defining apertures are among the more relevant factors to take into account. The impact of the results is also discussed, in particular in comparison with the information that can be extracted from conventional scanning small angle x-ray scattering (SAXS). Images of collagen tissues obtained by CXD reconstructions will give additional information about the local structure with higher resolution and will complement scanning SAXS images.

  9. Microscopy of biological sample through advanced diffractive optics from visible to X-ray wavelength regime.

    Science.gov (United States)

    Di Fabrizio, Enzo; Cojoc, Dan; Emiliani, Valentina; Cabrini, Stefano; Coppey-Moisan, Maite; Ferrari, Enrico; Garbin, Valeria; Altissimo, Matteo

    2004-11-01

    The aim of this report is to demonstrate a unified version of microscopy through the use of advanced diffractive optics. The unified scheme derives from the technical possibility of realizing front wave engineering in a wide range of electromagnetic spectrum. The unified treatment is realized through the design and nanofabrication of phase diffractive elements (PDE) through which wave front beam shaping is obtained. In particular, we will show applications, by using biological samples, ranging from micromanipulation using optical tweezers to X-ray differential interference contrast (DIC) microscopy combined with X-ray fluorescence. We report some details on the design and physical implementation of diffractive elements that besides focusing also perform other optical functions: beam splitting, beam intensity, and phase redistribution or mode conversion. Laser beam splitting is used for multiple trapping and independent manipulation of micro-beads surrounding a cell as an array of tweezers and for arraying and sorting microscopic size biological samples. Another application is the Gauss to Laguerre-Gauss mode conversion, which allows for trapping and transfering orbital angular momentum of light to micro-particles immersed in a fluid. These experiments are performed in an inverted optical microscope coupled with an infrared laser beam and a spatial light modulator for diffractive optics implementation. High-resolution optics, fabricated by means of e-beam lithography, are demonstrated to control the intensity and the phase of the sheared beams in x-ray DIC microscopy. DIC experiments with phase objects reveal a dramatic increase in image contrast compared to bright-field x-ray microscopy. Besides the topographic information, fluorescence allows detection of certain chemical elements (Cl, P, Sc, K) in the same setup, by changing the photon energy of the x-ray beam. (c) 2005 Wiley-Liss, Inc.

  10. Nondestructive strain depth profiling with high energy X-ray diffraction: System capabilities and limitations

    Science.gov (United States)

    Zhang, Zhan; Wendt, Scott; Cosentino, Nicholas; Bond, Leonard J.

    2018-04-01

    Limited by photon energy, and penetration capability, traditional X-ray diffraction (XRD) strain measurements are only capable of achieving a few microns depth due to the use of copper (Cu Kα1) or molybdenum (Mo Kα1) characteristic radiation. For deeper strain depth profiling, destructive methods are commonly necessary to access layers of interest by removing material. To investigate deeper depth profiles nondestructively, a laboratory bench-top high-energy X-ray diffraction (HEXRD) system was previously developed. This HEXRD method uses an industrial 320 kVp X-Ray tube and the Kα1 characteristic peak of tungsten, to produces a higher intensity X-ray beam which enables depth profiling measurement of lattice strain. An aluminum sample was investigated with deformation/load provided using a bending rig. It was shown that the HEXRD method is capable of strain depth profiling to 2.5 mm. The method was validated using an aluminum sample where both the HEXRD method and the traditional X-ray diffraction method gave data compared with that obtained using destructive etching layer removal, performed by a commercial provider. The results demonstrate comparable accuracy up to 0.8 mm depth. Nevertheless, higher attenuation capabilities in heavier metals limit the applications in other materials. Simulations predict that HEXRD works for steel and nickel in material up to 200 µm, but experiment results indicate that the HEXRD strain profile is not practical for steel and nickel material, and the measured diffraction signals are undetectable when compared to the noise.

  11. Strain fields in crystalline solids: prediction and measurement of X- ray diffraction patterns and electron diffraction contrast images

    NARCIS (Netherlands)

    Bor, Teunis Cornelis

    2000-01-01

    Lattice imperfections, such as dislocations and misfitting particles, shift and/or broaden X-ray diffraction (XRD) line profiles. Most of the present analysis methods of the shift and broadening of XRD line profiles do not provide the characteristics of lattice imperfections. The main part of this

  12. Characterization of nanophase materials by x-ray diffraction and computer simulation

    International Nuclear Information System (INIS)

    Eastman, J.A.; Thompson, L.J.

    1989-06-01

    X-ray diffraction experiments on nanophase Pd have been performed with the primary goal of determining the nature of grain boundary structures in nanophase materials. A kinematical diffraction analysis has been developed to interpret x-ray θ--2θ data by comparing actual scans with scans produced by computer simulation. This simulation program has been used to explore the effects on diffracted intensity of a variety of microstructural and grain boundary structural parameters such as void concentration, grain size, grain boundary width, and changes in interplanar spacing and density in grain boundary regions. It has been found that a reasonable match to experimental data is produced by at least two model structures; in one, the material contains randomly positioned voids or vacancies, while in the other, the interplanar spacings in grain boundary regions are varied with respect to the spacings found in the grain interiors. 7 refs., 4 figs

  13. In situ X-ray powder diffraction, synthesis, and magnetic properties of InVO 3

    Science.gov (United States)

    Lundgren, Rylan J.; Cranswick, Lachlan M. D.; Bieringer, Mario

    2006-12-01

    We report the first synthesis and high-temperature in situ X-ray diffraction study of InVO 3. Polycrystalline InVO 3 has been prepared via reduction of InVO 4 using a carbon monoxide/carbon dioxide buffer gas. InVO 3 crystallizes in the bixbyite structure in space group Ia-3 (206) with a=9.80636(31) Å with In 3+/V 3+ disorder on the (8 b) and (24 d) cation sites. In situ powder X-ray diffraction experiments and thermal gravimetric analysis in a CO/CO 2 buffer gas revealed the existence of the metastable phase InVO 3. Bulk samples with 98.5(2)% purity were prepared using low-temperature reduction methods. The preparative methods limited the crystallinity of this new phase to approximately 225(50) Å. Magnetic susceptibility and neutron diffraction experiments suggest a spin-glass ground state for InVO 3.

  14. Contained x-ray diffraction goniometer for examination of radioactive materials

    International Nuclear Information System (INIS)

    Smith, P.K.; Osgood, B.C.; Blaser, D.E.; Howell, R.E.; Stuhler, H.; Stauver, J.

    1987-11-01

    Radioactive materials are being characterized for chemical form and certain physical properties with an x-ray diffraction goniometer customized for containment in a shielded alpha glovebox. A Siemens D500 goniometer was customized by Siemens to locate the associated electronics and x-ray generator outside the glovebox to minimize corrosion and facilitate maintenance. A graphite monochromator is used with a shielded scintillation detector to separate diffracted x-radiation from nuclear radiation. The diffraction system is computer automated for data acquisition and reduction. The facility is designed to handle primarily alpha- and beta-emitting samples with moderate neutron and gamma radiation. Samples containing plutonium, enriched uranium, and other transuranic elements are analyzed in support of site nuclear operations and development programs on nuclear waste, chemical separations, reactor fuels, and product forms

  15. Femtosecond X-ray diffraction from an aerosolized beam of protein nanocrystals.

    Science.gov (United States)

    Awel, Salah; Kirian, Richard A; Wiedorn, Max O; Beyerlein, Kenneth R; Roth, Nils; Horke, Daniel A; Oberthür, Dominik; Knoska, Juraj; Mariani, Valerio; Morgan, Andrew; Adriano, Luigi; Tolstikova, Alexandra; Xavier, P Lourdu; Yefanov, Oleksandr; Aquila, Andrew; Barty, Anton; Roy-Chowdhury, Shatabdi; Hunter, Mark S; James, Daniel; Robinson, Joseph S; Weierstall, Uwe; Rode, Andrei V; Bajt, Saša; Küpper, Jochen; Chapman, Henry N

    2018-02-01

    High-resolution Bragg diffraction from aerosolized single granulovirus nanocrystals using an X-ray free-electron laser is demonstrated. The outer dimensions of the in-vacuum aerosol injector components are identical to conventional liquid-microjet nozzles used in serial diffraction experiments, which allows the injector to be utilized with standard mountings. As compared with liquid-jet injection, the X-ray scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. Such reduction is required for diffraction measurements of small macromolecular nanocrystals and single particles. High particle speeds are achieved, making the approach suitable for use at upcoming high-repetition-rate facilities.

  16. Purification, crystallization and preliminary X-ray diffraction experiment of nattokinase from Bacillus subtilis natto.

    Science.gov (United States)

    Yanagisawa, Yasuhide; Chatake, Toshiyuki; Chiba-Kamoshida, Kaori; Naito, Sawa; Ohsugi, Tadanori; Sumi, Hiroyuki; Yasuda, Ichiro; Morimoto, Yukio

    2010-12-01

    Nattokinase is a single polypeptide chain composed of 275 amino acids (molecular weight 27,724) which displays strong fibrinolytic activity. Moreover, it can activate other fibrinolytic enzymes such as pro-urokinase and tissue plasminogen activator. In the present study, native nattokinase from Bacillus subtilis natto was purified using gel-filtration chromatography and crystallized to give needle-like crystals which could be used for X-ray diffraction experiments. The crystals belonged to space group C2, with unit-cell parameters a=74.3, b=49.9, c=56.3 Å, β=95.2°. Diffraction images were processed to a resolution of 1.74 Å with an Rmerge of 5.2% (15.3% in the highest resolution shell) and a completeness of 69.8% (30.0% in the highest resolution shell). This study reports the first X-ray diffraction analysis of nattokinase.

  17. The Large Observatory For x-ray Timing

    DEFF Research Database (Denmark)

    Feroci, M.; Herder, J. W. den; Bozzo, E.

    2014-01-01

    The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study th...

  18. High-pressure X-ray diffraction studies of potassium chlorate

    Energy Technology Data Exchange (ETDEWEB)

    Pravica, Michael; Bai, Ligang; Bhattacharya, Neelanjan (UNLV)

    2012-03-15

    Two static high-pressure X-ray diffraction (XRD) studies of potassium chlorate have been performed at pressures of up to {approx}14.3 GPa in a diamond anvil cell at ambient temperature using the 16 ID-B undulator beamline at the Advanced Photon Source for the X-ray source. The first experiment was conducted to ascertain decomposition rates of potassium chlorate as a function of pressure. Below 2 GPa, the sample was observed to decompose rapidly in the presence of the X-ray beam and release oxygen. Above 2 GPa (near the phase I phase II transition), the decomposition rate dramatically slowed so that good quality XRD patterns could be acquired. This suggests a phase-dependent decomposition rate. In the second study, X-ray diffraction spectra were collected at pressures from 2 to 14.3 GPa by aligning virgin portions of the sample into the focused X-ray beam at each pressure. The results suggest the co-existence of mixed monoclinic (I) and rhombohedral (II) phases of potassium chlorate near 2 GPa. At pressures beyond 4 GPa, the XRD patterns show a very good fit to KClO{sub 3} in the rhombohedral phase with space group R3m, in agreement with earlier studies. No further phase transitions were observed with pressure. Decompression of the sample to ambient pressure indicated mixed phases I and II coupled with a small amount of synchrotron X-ray-induced decomposition product. The equation of state within this pressure regime has been determined.

  19. Correct interpretation of diffraction properties of quartz crystals for X-ray optics applications

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xian-Rong; Gog, Thomas; Kim, Jungho; Kasman, Elina; Said, Ayman H.; Casa, Diego M.; Wieczorek, Michael; Hönnicke, Marcelo G.; Assoufid, Lahsen

    2018-02-01

    Quartz has hundreds of strong Bragg reflections that may offer a great number of choices for making fixed-angle X-ray analyzers and polarizers at virtually any hard X-ray energies with selectable resolution. However, quartz crystals, unlike silicon and germanium, are chiral and may thus appear in two different forms of handedness that are mirror images. Furthermore, because of the threefold rotational symmetry along thecaxis, the {h1h2h3L} and {h2h1h3L} Bragg reflections may have quite different Darwin bandwidth, reflectivity and angular acceptance, although they have the same Bragg angle. The design of X-ray optics from quartz crystals therefore requires unambiguous determination of the orientation, handedness and polarity of the crystals. The Laue method and single-axis diffraction technique can provide such information, but the variety of conventions used in the literature to describe quartz structures has caused widespread confusion. The current studies give detailed guidelines for design and fabrication of quartz X-ray optics, with special emphasis on the correct interpretation of Laue patterns in terms of the crystallography and diffraction properties of quartz. Meanwhile, the quartz crystals examined were confirmed by X-ray topography to have acceptably low densities of dislocations and other defects, which is the foundation for developing high-resolution quartz-based X-ray optics.

  20. [Analysis and characterization of Belamcanda chinensis with space mutagenesis breeding by X-ray fluorescence analysis and X-ray diffraction].

    Science.gov (United States)

    Guan, Ying; Ding, Xi-Feng; Wang, Wen-Jing; Guo, Xi-Hua; Zhu, Yan-Ying

    2008-02-01

    The contents of various elements in the fourth generation Belamcanda chinensis (L.) DC. with space mutagenesis breeding were analyzed and characterized. X-ray fluorescence spectrum analysis (XRF) and powder X-ray diffraction (PXRD) were applied jointly. It was found that the content of K element in the space flight mutagenesis increases 1.03 and 0.31 times, Mg enhances 1.44 and 0.06 times, but Al reduces 38.5% and 85.5% respectively compared to the contents in the ground group and the comparison group, while those of Ca, Mn and Fe enhance 0.95, 0.30 and 0.29 times respectively contrasted to the ground group. Besides, there was discovered the crystal of whewellite in the Belamcanda chinensis (L.) DC. and the content in the ground group is less than that of the outer space and the outer space group, which in turn is less than that of the comparison group. It is concluded that the contents of mineral elements indispensable to body in the space group are closer or superior to the comparison, group as compared to the ground group. In the present paper, a quick and simple appraising method is offered, which may be of great significance to the popularization of the planting outer space Chinese traditional medicine to filtrate more excellent breed and set up norm of quality appraisal.

  1. Non-Destructive Quantification of Plastic Deformation in Steel: Employing X-Ray Diffraction Peak Broadening Analysis

    Science.gov (United States)

    2013-09-01

    justifier l’élaboration d’une nouvelle analyse des pics de DRX dans les installations de RDDC Atlantique. Résultats : Plusieurs auteurs se sont penchés...2 3 X-Ray Diffraction Theory ...3 X-Ray Diffraction Theory The manifestation of desirable physical and chemical material properties may be readily discerned through investigation

  2. Preliminary small-angle X-ray scattering and X-ray diffraction studies of the BTB domain of lola protein from Drosophila melanogaster

    Science.gov (United States)

    Boyko, K. M.; Nikolaeva, A. Yu.; Kachalova, G. S.; Bonchuk, A. N.; Dorovatovskii, P. V.; Popov, V. O.

    2017-11-01

    The Drosophila genome has several dozens of transcription factors (TTK group) containing BTB domains assembled into octamers. The LOLA protein belongs to this family. The purification, crystallization, and preliminary X-ray diffraction and small-angle X-ray scattering (SAXS) studies of the BTB domain of this protein are reported. The crystallization conditions were found by the vapor-diffusion technique. A very low diffraction resolution (8.7 Å resolution) of the crystals was insufficient for the determination of the threedimensional structure of the BTB domain. The SAXS study demonstrated that the BTB domain of the LOLA protein exists as an octamer in solution.

  3. Time-Resolved Hard X-Ray Spectrometer

    International Nuclear Information System (INIS)

    Kenneth Moya; Ian McKennaa; Thomas Keenana; Michael Cuneob

    2007-01-01

    Wired array studies are being conducted at the SNL Z accelerator to maximize the x-ray generation for inertial confinement fusion targets and high energy density physics experiments. An integral component of these studies is the characterization of the time-resolved spectral content of the x-rays. Due to potential spatial anisotropy in the emitted radiation, it is also critical to diagnose the time-evolved spectral content in a space-resolved manner. To accomplish these two measurement goals, we developed an x-ray spectrometer using a set of high-speed detectors (silicon PIN diodes) with a collimated field-of-view that converged on a 1-cm-diameter spot at the pinch axis. Spectral discrimination is achieved by placing high Z absorbers in front of these detectors. We built two spectrometers to permit simultaneous different angular views of the emitted radiation. Spectral data have been acquired from recent Z shots for the radial and polar views. UNSPEC1 has been adapted to analyze and unfold the measured data to reconstruct the x-ray spectrum. The unfold operator code, UFO2, is being adapted for a more comprehensive spectral unfolding treatment

  4. Analysis of the corium phases by X-ray diffraction; Analyses des phases du corium par diffraction des rayons X

    Energy Technology Data Exchange (ETDEWEB)

    Trillon, G

    2004-07-01

    In the framework of the severe accidents R and D studies led by CEA, the better knowledge of the corium behaviour, corium coming from the melting of a nuclear reactor, are fundamental stakes in order to master this kind of accident. Among the available physical properties of the corium, the nature of the final crystalline compounds which have been made during the, cooling gives information about its solidification and its stabilisation. X-Rays Diffraction is the reference method used in order to characterize the corium coming from the different facilities of the European platform PLINIUS of CEA-Cadarache. This work presents the scientific approach that has been followed in order to obtain information both qualitative and quantitative on corium, using X-Rays Diffraction. For instance, a specific method for identifying U{sub 1-x}Zr{sub x}O{sub 2} solid solutions has been developed, and the validity of quantitative analysis of corium crystalline phases using the Rietveld method (with an internal standard), has been tested. This last method has also permitted semi-quantitative measurements of amorphous phases within corium. For these studies, analysis of prototypical corium has been conducted on samples coming from the experiences led on the different facilities of the PLINIUS platform. These analysis allowed for the first time to obtain quantitative data of the corium crystalline phases in order to validate thermodynamic databases and has been used to estimate the thereto-physical properties of the corium. New information on crystalline phases of corium has also been found, especially for the UO{sub 2}-ZrO{sub 2} pseudo binary system. (author)

  5. A Monte Carlo error simulation applied to calibration-free X-ray diffraction phase analysis

    International Nuclear Information System (INIS)

    Braun, G.E.

    1986-01-01

    Quantitative phase analysis of a system of n phases can be effected without the need for calibration standards provided at least n different mixtures of these phases are available. A series of linear equations relating diffracted X-ray intensities, weight fractions and quantitation factors coupled with mass balance relationships can be solved for the unknown weight fractions and factors. Uncertainties associated with the measured X-ray intensities, owing to counting of random X-ray quanta, are used to estimate the errors in the calculated parameters utilizing a Monte Carlo simulation. The Monte Carlo approach can be generalized and applied to any quantitative X-ray diffraction phase analysis method. Two examples utilizing mixtures of CaCO 3 , Fe 2 O 3 and CaF 2 with an α-SiO 2 (quartz) internal standard illustrate the quantitative method and corresponding error analysis. One example is well conditioned; the other is poorly conditioned and, therefore, very sensitive to errors in the measured intensities. (orig.)

  6. Pressure-induced crystallization and phase transformation of amorphous selenium: Raman spectroscopy and x-ray diffraction studies

    International Nuclear Information System (INIS)

    Yang Kaifeng; Cui Qiliang; Hou Yuanyuan; Liu Bingbing; Zhou Qiang; Hu Jingzhu; Mao, H-K; Zou Guangtian

    2007-01-01

    High-pressure Raman spectroscopy studies have been carried out on amorphous Se (a-Se) at room temperature in a diamond anvil cell with an 830 nm exciting line. Raman evidence for the pressure-induced crystallization of a-Se and the coexistence of the unknown high-pressure phase with the hexagonal phase is presented for the first time. Further experimental proof of high-pressure angle-dispersive x-ray diffraction studies for a-Se indicates that the unknown high-pressure phase is also a mixture phase of the tetragonal I4 1 /acd and Se IV structure. Our Raman and x-ray diffraction results suggest that hexagonal Se I undergoes a direct transition to triclinic Se III at about 19 GPa, which is in good agreement with the theoretical prediction

  7. Time response characteristics of X-ray detector system on Silex-Ⅰ laser facility

    International Nuclear Information System (INIS)

    Yi Rongqing; He Xiao'an; Li Hang; Du Huabing; Zhang Haiying; Cao Zhurong

    2013-01-01

    On the Silex-Ⅰ laser facility, the time response characteristics of XRD detector were studied. A laser with a pulse of 32 fs and a wavelength of 800 nm was used to irradiate a plane Au target. X-ray calibrated method of time of exposure X-ray framing camera and time resolution of X-ray streak camera was explored. The time response characteristics of XRD detector and time process of X-ray emission were obtained from experiment. We obtained X-ray calibration method of time of exposure X-ray framing camera and time resolution of X-ray streak camera. (authors)

  8. Complete k-space visualization of x-ray photoelectron diffraction

    International Nuclear Information System (INIS)

    Denlinger, J.D.; Lawrence Berkeley Lab., CA; Rotenberg, E.; Lawrence Berkeley Lab., CA; Kevan, S.D.; Tonner, B.P.

    1996-01-01

    A highly detailed x-ray photoelectron diffraction data set has been acquired for crystalline Cu(001). The data set for bulk Cu 3p emission encompasses a large k-space volume (k = 3--10 angstrom -1 ) with sufficient energy and angular sampling to monitor the continuous variation of diffraction intensities. The evolution of back-scattered intensity oscillations is visualized by energy and angular slices of this volume data set. Large diffraction data sets such as this will provide rigorous experimental tests of real-space reconstruction algorithms and multiple-scattering simulations

  9. Influence of beam divergence on form-factor in X-ray diffraction radiation

    International Nuclear Information System (INIS)

    Sergeeva, D.Yu.; Tishchenko, A.A.; Strikhanov, M.N.

    2015-01-01

    Diffraction radiation from divergent beam is considered in terms of radiation in UV and X-ray range. Scedastic form of Gaussian distribution of the particle in the bunch, i.e. Gaussian distribution with changing dispersion has been used, which is more adequate for description of divergent beams than often used Gaussian distribution with constant dispersion. Both coherent and incoherent form-factors are taken into account. The conical diffraction effect in diffraction radiation is proved to make essential contribution in spectral-angular characteristics of radiation from a divergent beam

  10. Identification of inversion domains in KTiOPO{sub 4}via resonant X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Fabrizi, Federica, E-mail: federica.fabrizi@diamond.ac.uk [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, OX11 0DE (United Kingdom); Thomas, Pamela A. [Department of Physics, University of Warwick, Coventry, CV4 7AL (United Kingdom); Nisbet, Gareth; Collins, Stephen P. [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, OX11 0DE (United Kingdom)

    2015-05-14

    The identification and high-resolution mapping of the absolute crystallographic structure in multi-domain ferroelectric KTiOPO{sub 4} is achieved through a novel synchrotron X-ray diffraction method. On a single Bragg reflection, the intensity ratio in resonant diffraction below and above the Ti absorption K edge demonstrates a domain contrast up to a factor of ∼270, thus implementing a non-contact, non-destructive imaging technique with micrometre spatial resolution, applicable to samples of arbitrarily large dimensions. A novel method is presented for the identification of the absolute crystallographic structure in multi-domain polar materials such as ferroelectric KTiOPO{sub 4}. Resonant (or ‘anomalous’) X-ray diffraction spectra collected across the absorption K edge of Ti (4.966 keV) on a single Bragg reflection demonstrate a huge intensity ratio above and below the edge, providing a polar domain contrast of ∼270. This allows one to map the spatial domain distribution in a periodically inverted sample, with a resolution of ∼1 µm achieved with a microfocused beam. This non-contact, non-destructive technique is well suited for samples of large dimensions (in contrast with traditional resonant X-ray methods based on diffraction from Friedel pairs), and its potential is particularly relevant in the context of physical phenomena connected with an absence of inversion symmetry, which require characterization of the underlying absolute atomic structure (such as in the case of magnetoelectric coupling and multiferroics)

  11. Influence of preferred orientation of minerals in the mineralogical identification process by X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Amanda Luzia da; Oliveira, Arno H. de [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Fernandes, Maria Lourdes Souza, E-mail: lourdesfernandes@ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Inst. de GeoCiencias. Centro de Pesquisa Professor Manoel Teixeira da Costa

    2011-07-01

    The X-ray diffraction corresponds to one of the main techniques for characterization of microstructures in crystalline materials, widely used in the identification of minerals in samples of geological materials. Some minerals have a property called preferred orientation which corresponds to the orientation tendency of the crystals of ground minerals to orient themselves in certain directions according to a preferred crystallographic plane. This property affects the analysis by X-ray diffraction and this fact can generates erroneous results in the characterization. The purpose of this study is to identify the negative influence of the preferred orientation of a mineral in the generation of diffraction patterns obtained in the X-ray diffraction analysis. For this, a sample of muscovite, a mineral of mica group, was prepared by two different methods: the frontal method and the back loading method. In the analysis using the frontal method there was displacement of the XRD pattern in the abscissa axis, where it was observed changes in interplanar distance and angle 2{theta} values, which are essential information for characterization and identification of a mineral. In the analysis using the back loading method, the generated XRD pattern showed no displacement in the axis of abscissas and showed interplanar distance and angle 2{theta} values closer to the real values for the muscovite. The results showed that one can only make improvements to the process of sample preparation minimizing the effect of preferred orientation in the analysis. There is no need to change conditions of diffractometer measurements. (author)

  12. Innovative diffraction gratings for high-resolution resonant inelastic soft x-ray scattering spectroscopy

    International Nuclear Information System (INIS)

    Voronov, D.L.; Warwick, T.; Gullikson, E. M.; Salmassi, F.; Padmore, H. A.

    2016-01-01

    High-resolution Resonant Inelastic X-ray Scattering (RIXS) requires diffraction gratings with very exacting characteristics. The gratings should provide both very high dispersion and high efficiency which are conflicting requirements and extremely challenging to satisfy in the soft x-ray region for a traditional grazing incidence geometry. To achieve high dispersion one should increase the groove density of a grating; this however results in a diffraction angle beyond the critical angle range and results in drastic efficiency loss. The problem can be solved by use of multilayer coated blazed gratings (MBG). In this work we have investigated the diffraction characteristics of MBGs via numerical simulations and have developed a procedure for optimization of grating design for a multiplexed high resolution imaging spectrometer for RIXS spectroscopy to be built in sector 6 at the Advanced Light Source (ALS). We found that highest diffraction efficiency can be achieved for gratings optimized for 4"t"h or 5"t"h order operation. Fabrication of such gratings is an extremely challenging technological problem. We present a first experimental prototype of these gratings and report its performance. High order and high line density gratings have the potential to be a revolutionary new optical element that should have great impact in the area of soft x-ray RIXS.

  13. Influence of preferred orientation of minerals in the mineralogical identification process by X-ray diffraction

    International Nuclear Information System (INIS)

    Silva, Amanda Luzia da; Oliveira, Arno H. de; Fernandes, Maria Lourdes Souza

    2011-01-01

    The X-ray diffraction corresponds to one of the main techniques for characterization of microstructures in crystalline materials, widely used in the identification of minerals in samples of geological materials. Some minerals have a property called preferred orientation which corresponds to the orientation tendency of the crystals of ground minerals to orient themselves in certain directions according to a preferred crystallographic plane. This property affects the analysis by X-ray diffraction and this fact can generates erroneous results in the characterization. The purpose of this study is to identify the negative influence of the preferred orientation of a mineral in the generation of diffraction patterns obtained in the X-ray diffraction analysis. For this, a sample of muscovite, a mineral of mica group, was prepared by two different methods: the frontal method and the back loading method. In the analysis using the frontal method there was displacement of the XRD pattern in the abscissa axis, where it was observed changes in interplanar distance and angle 2θ values, which are essential information for characterization and identification of a mineral. In the analysis using the back loading method, the generated XRD pattern showed no displacement in the axis of abscissas and showed interplanar distance and angle 2θ values closer to the real values for the muscovite. The results showed that one can only make improvements to the process of sample preparation minimizing the effect of preferred orientation in the analysis. There is no need to change conditions of diffractometer measurements. (author)

  14. Purification, crystallization and preliminary X-ray diffraction experiment of nattokinase from Bacillus subtilis natto

    International Nuclear Information System (INIS)

    Yanagisawa, Yasuhide; Chatake, Toshiyuki; Chiba-Kamoshida, Kaori; Naito, Sawa; Ohsugi, Tadanori; Sumi, Hiroyuki; Yasuda, Ichiro; Morimoto, Yukio

    2010-01-01

    Nattokinase, a protein found in high levels in the traditional Japanese food natto, has been reported to have high thrombolytic activity. In the present study, the crystallization of native nattokinase and the collection of X-ray diffraction date from a nattokinase crystal to a resolution of 1.74 Å are reported. Nattokinase is a single polypeptide chain composed of 275 amino acids (molecular weight 27 724) which displays strong fibrinolytic activity. Moreover, it can activate other fibrinolytic enzymes such as pro-urokinase and tissue plasminogen activator. In the present study, native nattokinase from Bacillus subtilis natto was purified using gel-filtration chromatography and crystallized to give needle-like crystals which could be used for X-ray diffraction experiments. The crystals belonged to space group C2, with unit-cell parameters a = 74.3, b = 49.9, c = 56.3 Å, β = 95.2°. Diffraction images were processed to a resolution of 1.74 Å with an R merge of 5.2% (15.3% in the highest resolution shell) and a completeness of 69.8% (30.0% in the highest resolution shell). This study reports the first X-ray diffraction analysis of nattokinase

  15. Purification, crystallization and preliminary X-ray diffraction experiment of nattokinase from Bacillus subtilis natto

    Energy Technology Data Exchange (ETDEWEB)

    Yanagisawa, Yasuhide [Faculty of Pharmaceutical Sciences, Chiba Institute of Science, 15-8 Shiomi-cho, Choshi, Chiba 288-0025 (Japan); Chatake, Toshiyuki [Research Reactor Institute, Kyoto University, Asashironishi 2, Kumatori, Sennan, Osaka 590-0494 (Japan); Chiba-Kamoshida, Kaori [National Institute of Advanced Industrial Science and Technology (AIST), Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan); Naito, Sawa; Ohsugi, Tadanori; Sumi, Hiroyuki [Kurashiki University of Science and Arts, Nishinoura 2640, Tsurajima-cho, Kurashiki, Okayama 712-8505 (Japan); Yasuda, Ichiro [Faculty of Pharmaceutical Sciences, Chiba Institute of Science, 15-8 Shiomi-cho, Choshi, Chiba 288-0025 (Japan); Morimoto, Yukio [Research Reactor Institute, Kyoto University, Asashironishi 2, Kumatori, Sennan, Osaka 590-0494 (Japan); Faculty of Pharmaceutical Sciences, Chiba Institute of Science, 15-8 Shiomi-cho, Choshi, Chiba 288-0025 (Japan)

    2010-12-01

    Nattokinase, a protein found in high levels in the traditional Japanese food natto, has been reported to have high thrombolytic activity. In the present study, the crystallization of native nattokinase and the collection of X-ray diffraction date from a nattokinase crystal to a resolution of 1.74 Å are reported. Nattokinase is a single polypeptide chain composed of 275 amino acids (molecular weight 27 724) which displays strong fibrinolytic activity. Moreover, it can activate other fibrinolytic enzymes such as pro-urokinase and tissue plasminogen activator. In the present study, native nattokinase from Bacillus subtilis natto was purified using gel-filtration chromatography and crystallized to give needle-like crystals which could be used for X-ray diffraction experiments. The crystals belonged to space group C2, with unit-cell parameters a = 74.3, b = 49.9, c = 56.3 Å, β = 95.2°. Diffraction images were processed to a resolution of 1.74 Å with an R{sub merge} of 5.2% (15.3% in the highest resolution shell) and a completeness of 69.8% (30.0% in the highest resolution shell). This study reports the first X-ray diffraction analysis of nattokinase.

  16. The Scherrer equation and the dynamical theory of X-ray diffraction.

    Science.gov (United States)

    Muniz, Francisco Tiago Leitão; Miranda, Marcus Aurélio Ribeiro; Morilla Dos Santos, Cássio; Sasaki, José Marcos

    2016-05-01

    The Scherrer equation is a widely used tool to determine the crystallite size of polycrystalline samples. However, it is not clear if one can apply it to large crystallite sizes because its derivation is based on the kinematical theory of X-ray diffraction. For large and perfect crystals, it is more appropriate to use the dynamical theory of X-ray diffraction. Because of the appearance of polycrystalline materials with a high degree of crystalline perfection and large sizes, it is the authors' belief that it is important to establish the crystallite size limit for which the Scherrer equation can be applied. In this work, the diffraction peak profiles are calculated using the dynamical theory of X-ray diffraction for several Bragg reflections and crystallite sizes for Si, LaB6 and CeO2. The full width at half-maximum is then extracted and the crystallite size is computed using the Scherrer equation. It is shown that for crystals with linear absorption coefficients below 2117.3 cm(-1) the Scherrer equation is valid for crystallites with sizes up to 600 nm. It is also shown that as the size increases only the peaks at higher 2θ angles give good results, and if one uses peaks with 2θ > 60° the limit for use of the Scherrer equation would go up to 1 µm.

  17. Apparatus development for high-pressure X-ray diffraction using synchrotron radiation

    International Nuclear Information System (INIS)

    Martinez, L.G.; Orlando, M.T.D.; Rossi, J.L.; Passamai Junior, J.L.; Melo, F.C.L.; Ferreira, F.F.

    2006-01-01

    Some phenomena in the field of condensed matter physics can be studied when the matter is submitted to extreme conditions of pressure, magnetic fields or temperatures. Once submitted to these conditions it is generally necessary to measure the properties of the matter in situ. The existence of a synchrotron light laboratory in Brazil opens up the chance of studying materials in extreme conditions by techniques like X-ray diffraction and absorption. However, when compared to high-energy synchrotrons accelerators, the Brazilian source offers a narrower energy range and lower flux. These facts impose limitation to perform diffraction experiments by energy dispersion and, consequently, the use of pressure cells with denser anvils like diamond. However, for a lower-pressure range, preliminary studies showed the viability of measurements in an angular dispersion configuration. This allows the use of silicon carbide anvils B 4C . In this work it is described the development of a hydrostatic pressure cell suitable for X-rays diffraction measurements in the Brazilian Synchrotron Light Laboratory using materials and technologies developed by the institutions and researchers involved in this project (IPEN, UFES, CTA and LNLS). This development can provide the scientific community with the possibility of performing X-ray diffraction measurements under hydrostatic pressure, initially up to 2 GPa, with possibilities of increasing the maximum pressure to higher values, with or without application of magnetic fields and high or low temperatures. (author)

  18. The structural analysis of zinc borate glass by laboratory EXAFS and X-ray diffraction measurements

    International Nuclear Information System (INIS)

    Kajinami, Akihiko; Harada, Yasushi; Inoue, Shinsuke; Deki, Shigehito; Umesaki, Norimasa

    1999-01-01

    The structure of zinc borate glass has been investigated by laboratory EXAFS and X-ray diffraction measurement as preliminary investigations for the detailed study in SPring-8. The zinc borate glass was prepared in the range from 40 to 65 mol% of zinc oxide content. The X-ray diffraction was measured by horizontal θ-θ goniometer with 60 kV and 300 mA output of Mo target. The EXAFS of zinc borate glass was measured by laboratory EXAFS system with 20 kV, 100 mA output of Mo target for the K absorption edge of zinc atom. From the X-ray diffraction and the EXAFS measurements, it is found that the zinc ion is surrounded by four oxygen atoms and formed a tetrahedral structure whose (Zn-O) distance is about 2 A and that the structure is unchanged with the zinc oxide content. The diffraction data show that the neighboring structure of boron atom transforms from BO 4 tetrahedra to BO 3 tetragonal planar structure with increasing of the zinc oxide content. (author)

  19. Time Resolved X-Ray Spot Size Diagnostic

    CERN Document Server

    Richardson, Roger; Falabella, Steven; Guethlein, Gary; Raymond, Brett; Weir, John

    2005-01-01

    A diagnostic was developed for the determination of temporal history of an X-ray spot. A pair of thin (0.5 mm) slits image the x-ray spot to a fast scintillator which is coupled to a fast detector, thus sampling a slice of the X-Ray spot. Two other scintillator/detectors are used to determine the position of the spot and total forward dose. The slit signal is normalized to the dose and the resulting signal is analyzed to get the spot size. The position information is used to compensate for small changes due to spot motion and misalignment. The time resolution of the diagnostic is about 1 ns and measures spots from 0.5 mm to over 3 mm. The theory and equations used to calculate spot size and position are presented, as well as data. The calculations assume a symmetric, Gaussian spot. The spot data is generated by the ETA II accelerator, a 2kA, 5.5 MeV, 60ns electron beam focused on a Tantalum target. The spot generated is typically about 1 mm FWHM. Comparisons are made to an X-ray pinhole camera which images th...

  20. Time-resolved protein nano-crystallography using an X-ray free-electron laser

    International Nuclear Information System (INIS)

    Aquila, Andrew; Hunter, Mark S.; Fromme, Petra; Fromme, Raimund; Grotjohann, Ingo; Doak, R. Bruce; Kirian, Richard A.; Schmidt, Kevin E.; Wang, Xiaoyu; Weierstall, Uwe; Spence, John C.H.; White, Thomas A.; Caleman, Carl; DePonte, Daniel P.; Fleckenstein, Holger; Gumprecht, Lars; Liang, Mengning; Martin, Andrew V.; Schulz, Joachim; Stellato, Francesco; Stern, Stephan; Barty, Anton; Andreasson, Jakob; Davidsson, Jan; Hajdu, Janos; Maia, Filipe R.N.C.; Seibert, M. Marvin; Timneanu, Nicusor; Arnlund, David; Johansson, Linda; Malmerberg, Erik; Neutze, Richard; Bajt, Sasa; Barthelmess, Miriam; Graafsma, Heinz; Hirsemann, Helmut; Wunderer, Cornelia; Barends, Thomas R.M.; Foucar, Lutz; Krasniqi, Faton; Lomb, Lukas; Rolles, Daniel; Schlichting, Ilme; Schmidt, Carlo; Bogan, Michael J.; Hampton, Christina Y.; Sierra, Raymond; Starodub, Dmitri; Bostedt, Christoph; Bozek, John D.; Messerschmidt, Marc; Williams, Garth J.; Bottin, Herve

    2012-01-01

    We demonstrate the use of an X-ray free electron laser synchronized with an optical pump laser to obtain X-ray diffraction snapshots from the photo-activated states of large membrane protein complexes in the form of nano-crystals flowing in a liquid jet. Light-induced changes of Photosystem I-Ferredoxin co-crystals were observed at time delays of 5 to 10 μs after excitation. The result correlates with the microsecond kinetics of electron transfer from Photosystem I to ferredoxin. The undocking process that follows the electron transfer leads to large rearrangements in the crystals that will terminally lead to the disintegration of the crystals. We describe the experimental setup and obtain the first time resolved femtosecond serial X-ray crystallography results from an irreversible photo-chemical reaction at the Linac Coherent Light Source. This technique opens the door to time-resolved structural studies of reaction dynamics in biological systems. (authors)

  1. First use of portable system coupling X-ray diffraction and X-ray fluorescence for in-situ analysis of prehistoric rock art.

    Science.gov (United States)

    Beck, L; Rousselière, H; Castaing, J; Duran, A; Lebon, M; Moignard, B; Plassard, F

    2014-11-01

    Study of prehistoric art is playing a major role in the knowledge of human evolution. Many scientific methods are involved in this investigation including chemical analysis of pigments present on artefacts or applied to cave walls. In the past decades, the characterization of coloured materials was carried on by taking small samples. This procedure had two main disadvantages: slight but existing damage of the paintings and limitation of the number of samples. Thanks to the advanced development of portable systems, in-situ analysis of pigment in cave can be now undertaken without fear for this fragile Cultural Heritage. For the first time, a portable system combining XRD and XRF was used in an underground and archaeological environment for prehistoric rock art studies. In-situ non-destructive analysis of black prehistoric drawings and determination of their composition and crystalline structure were successfully carried out. Original results on pigments used 13,000 years ago in the cave of Rouffignac (France) were obtained showing the use of two main manganese oxides: pyrolusite and romanechite. The capabilities of the portable XRD-XRF system have been demonstrated for the characterization of pigments as well as for the analysis of rock in a cave environment. This first in-situ experiment combining X-ray diffraction and X-ray fluorescence open up new horizons and can fundamentally change our approach of rock art studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Fast X-ray powder diffraction on I11 at Diamond.

    Science.gov (United States)

    Thompson, Stephen P; Parker, Julia E; Marchal, Julien; Potter, Jonathan; Birt, Adrian; Yuan, Fajin; Fearn, Richard D; Lennie, Alistair R; Street, Steven R; Tang, Chiu C

    2011-07-01

    The commissioning and performance characterization of a position-sensitive detector designed for fast X-ray powder diffraction experiments on beamline I11 at Diamond Light Source are described. The detecting elements comprise 18 detector-readout modules of MYTHEN-II silicon strip technology tiled to provide 90° coverage in 2θ. The modules are located in a rigid housing custom designed at Diamond with control of the device fully integrated into the beamline data acquisition environment. The detector is mounted on the I11 three-circle powder diffractometer to provide an intrinsic resolution of Δ2θ approximately equal to 0.004°. The results of commissioning and performance measurements using reference samples (Si and AgI) are presented, along with new results from scientific experiments selected to demonstrate the suitability of this facility for powder diffraction experiments where conventional angle scanning is too slow to capture rapid structural changes. The real-time dehydrogenation of MgH(2), a potential hydrogen storage compound, is investigated along with ultrafast high-throughput measurements to determine the crystallite quality of different samples of the metastable carbonate phase vaterite (CaCO(3)) precipitated and stabilized in the presence of amino acid molecules in a biomimetic synthesis process.

  3. Origin of nondetectable x-ray diffraction peaks in nanocomposite CuTiZr alloys

    DEFF Research Database (Denmark)

    Jiang, Jianzhong; Kato, H.; Ohsuna, T.

    2003-01-01

    Microscopic structures of Cu60Ti10+xZr30-x (x=0 and 10) alloys have been investigated by transmission electron microscopy, x-ray diffraction (XRD) and differential scanning calorimeter (DSC). In the Cu60Ti10Zr30 samples annealed at 708 K for times ranging from 0 to 130 min, where the enthalpy...... of the first exothermic peak decreases by 80%, the corresponding XRD patterns still look similar to that for the as-prepared sample. However, the simulated XRD patterns for the pure Cu51Zr14 phase, which is the crystalline phase formed during the first exothermic reaction, with small grain sizes and defects...... clearly show a broadened amorphous-like feature. This might be the reason that no diffraction peaks from the nanocrystalline component were detected in the XRD patterns recorded for the as-cast or as-spun Cu60Ti10+xZr30-x (x=0 and 10) alloys and for the alloys annealed at lower temperatures, in which...

  4. Ultrathin Pt films on Ni(111): Structure determined by surface x-ray diffraction

    International Nuclear Information System (INIS)

    Robach, O.; Isern, H.; Quiros, C.; Ferrer, S.; Steadman, P.; Peters, K. F.

    2003-01-01

    The growth of platinum on a nickel (111) single crystal under ultrahigh vacuum conditions was studied using surface x-ray diffraction on the ID03 beamline of the ESRF. Film thickness ranged from one to eight monoatomic layers (ML). Specular reflectivity was used to determine the growth mode and vertical lattice parameter of the Pt film. A two-dimensional (2D) growth up to 1 ML followed by more 3D growth was found. A small expansion of the Pt vertical lattice parameter was found. The Pt in-plane lattice parameter was measured. Its relaxation was found to be very slow, with a residual contraction of 2.3% in an 8-ML-thick film (with respect to bulk Pt). A Ni crystal truncation rod measured before and after growing 1 ML of Pt revealed the presence of a small amount of pseudomorphic Pt, adsorbed on both fcc and hcp sites. The stacking of the (111) Pt planes was investigated by measuring stacking-sensitive Pt diffraction rods. A strong tendency to stacking reversal was found at room temperature, with an amount of 'reversed' Pt about ten times higher than the amount of Pt with the same stacking as the Ni. An eight-layer Ni film on Pt(111) was also studied for comparison

  5. Theoretical study of the properties of X-ray diffraction moiré fringes. I

    International Nuclear Information System (INIS)

    Yoshimura, Jun-ichi

    2015-01-01

    A detailed and comprehensive theoretical description of X-ray diffraction moiré fringes for a bicrystal specimen is given on the basis of a calculation by plane-wave dynamical diffraction theory, where the effect of the Pendellösung intensity oscillation on the moiré pattern is explained in detail. A detailed and comprehensive theoretical description of X-ray diffraction moiré fringes for a bicrystal specimen is given on the basis of a calculation by plane-wave dynamical diffraction theory. Firstly, prior to discussing the main subject of the paper, a previous article [Yoshimura (1997 ▸). Acta Cryst. A53, 810–812] on the two-dimensionality of diffraction moiré patterns is restated on a thorough calculation of the moiré interference phase. Then, the properties of moiré fringes derived from the above theory are explained for the case of a plane-wave diffraction image, where the significant effect of Pendellösung intensity oscillation on the moiré pattern when the crystal is strained is described in detail with theoretically simulated moiré images. Although such plane-wave moiré images are not widely observed in a nearly pure form, knowledge of their properties is essential for the understanding of diffraction moiré fringes in general

  6. Mössbauer, magnetization and X-ray diffraction characterization methods for iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Gabbasov, Raul, E-mail: gabbasov-raul@yandex.ru [National Research Center “Kurchatov Institute”, Moscow (Russian Federation); Polikarpov, Michael; Cherepanov, Valery [National Research Center “Kurchatov Institute”, Moscow (Russian Federation); Chuev, Michael; Mischenko, Iliya; Lomov, Andrey [Institute of Physics and Technology, Russian Academy of Sciences, Moscow (Russian Federation); Wang, Andrew [Ocean NanoTech. Springdale, AR (United States); Panchenko, Vladislav [National Research Center “Kurchatov Institute”, Moscow (Russian Federation)

    2015-04-15

    Water soluble magnetite iron oxide nanoparticles with oleic polymer coating and average diameters in the range of 5–25 nm, previously determined by TEM, were characterized using Mössbauer, magnetization and X-ray diffraction measurements. Comparative analysis of the results demonstrated a large diversity of magnetic relaxation regimes. Analysis showed the presence of an additional impurity component in the 25 nm nanoparticles, with principally different magnetic nature at the magnetite core. In some cases, X-ray diffraction measurements were unable to estimate the size of the magnetic core and Mössbauer data were necessary for the correct interpretation of the experimental results. - Highlights: • KV parameter, obtained from Mössbauer spectra can be used for nanoparticle size characterization. • Mössbauer spectra of 10–25 nm nanoparticles can be effectively described by ferromagnetic model. • Surface impurities can cause incorrect nanoparticle size determination.

  7. X-ray diffraction study of phase transitions in iron(II) trisnioximate hexadecylboronate clathrochelate complex

    International Nuclear Information System (INIS)

    Vorontsov, I.I.; Antipin, M.Yu.; Dubovik, I.I.; Papkov, V.S.; Potekhin, K.A.; Voloshin, Ya.Z.; Stash, A.I.; Belsky, V.K.

    2001-01-01

    Crystals of the iron(II) nioximate hexadecylboronate clathrochelate complex-FeNx 3 (BHd ) 2 [tris(μ-1,2-cyclohexanedionedioximato-O:O ' )di-n-hexadecyldiborato(2-) - N,'''N''',N''',N''',N''',N ' ]iron(II) - are investigated by differential scanning calorimetry and X-ray diffraction. Two structural phase transitions are revealed at T cr1 = 290(3) K and T cr2 = 190(3) K. The crystal structures of phases I, II, and III are determined by X-ray diffraction analysis at 303, 243, and 153 K, respectively. It is demonstrated that the I ↔ II phase transition is due to a change in the system of translations, and the II ↔ III phase transition is accompanied only by a jumpwise change in the unit cell parameters. The possible mechanisms of phase transitions are discussed in terms of geometry and molecular packing of FeNx 3 (BHd) 2 in all three phases

  8. Crystallization and preliminary X-ray diffraction analysis of maize aldose reductase

    Energy Technology Data Exchange (ETDEWEB)

    Kiyota, Eduardo [Laboratório de Biologia Estrutural, Instituto de Química, Universidade Estadual de Campinas, CP 6154, 13083-970 Campinas-SP (Brazil); Centro de Biologia Molecular e Engenharia Genética, Universidade Estadual de Campinas, Campinas-SP (Brazil); Sousa, Sylvia Morais de [Centro de Biologia Molecular e Engenharia Genética, Universidade Estadual de Campinas, Campinas-SP (Brazil); Santos, Marcelo Leite dos; Costa Lima, Aline da [Laboratório de Biologia Estrutural, Instituto de Química, Universidade Estadual de Campinas, CP 6154, 13083-970 Campinas-SP (Brazil); Menossi, Marcelo [Departamento de Genética e Evolução, Instituto de Biologia, Universidade Estadual de Campinas, Campinas-SP (Brazil); Yunes, José Andrés [Laboratório de Biologia Molecular, Centro Infantil Boldrini, Campinas-SP (Brazil); Aparicio, Ricardo, E-mail: aparicio@iqm.unicamp.br [Laboratório de Biologia Estrutural, Instituto de Química, Universidade Estadual de Campinas, CP 6154, 13083-970 Campinas-SP (Brazil)

    2007-11-01

    Preliminary X-ray diffraction studies of apo maize aldose reductase at 2.0 Å resolution are reported. Maize aldose reductase (AR) is a member of the aldo-keto reductase superfamily. In contrast to human AR, maize AR seems to prefer the conversion of sorbitol into glucose. The apoenzyme was crystallized in space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 47.2, b = 54.5, c = 100.6 Å and one molecule in the asymmetric unit. Synchrotron X-ray diffraction data were collected and a final resolution limit of 2.0 Å was obtained after data reduction. Phasing was carried out by an automated molecular-replacement procedure and structural refinement is currently in progress. The refined structure is expected to shed light on the functional/enzymatic mechanism and the unusual activities of maize AR.

  9. X-ray diffraction, Raman and photoacoustic studies of InSb nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Ersching, K., E-mail: kleb85@hotmail.com [Departamento de Fisica, Universidade Federal de Santa Catarina, Campus Universitario Trindade, 88040-900 Florianopolis, Santa Catarina (Brazil); Campos, C.E.M.; Lima, J.C. de; Grandi, T.A. [Departamento de Fisica, Universidade Federal de Santa Catarina, Campus Universitario Trindade, 88040-900 Florianopolis, Santa Catarina (Brazil); Souza, S.M. [Departamento de Engenharia Mecanica, Universidade Federal de Santa Catarina, Campus Universitario Trindade, 88040-900 Florianopolis, Santa Catarina (Brazil); Pizani, P.S. [Departamento de Fisica, Universidade Federal de Sao Carlos, 13 565-905 Sao Carlos, SP (Brazil)

    2010-08-01

    Zinc blend InSb nanocrystals were generated by mechanical alloying and X-ray diffraction, Raman spectroscopy and photoacoustic absorption spectroscopy techniques were used to study its structural, optical and thermal properties. Annealed nanocrystals were also studied. Residual amorphous and minority crystalline (Sb and In{sub 2}O{sub 3}) phases were also observed for mechanical alloyed and thermal annealed samples, respectively. The structural parameters, phase fractions, average crystallite sizes and microstrains of all crystalline phases found in the samples were obtained from Rietveld analyses of their X-ray diffraction patterns. Raman results for both as-milled and annealed samples show the Raman active LO and TO modes of the zinc blend InSb phase and Sb-rich regions. The photoacoustic results of both samples were satisfactorily explained by thermal bending heat transfer mechanism and an increase on effective thermal diffusivity coefficient was observed after annealing.

  10. Atomic structure of large angle grain boundaries determined by quantitative X-ray diffraction techniques

    International Nuclear Information System (INIS)

    Fitzsimmons, M.R.; Sass, S.L.

    1988-01-01

    Quantitative X-ray diffraction techniques have been used to determine the atomic structure of the Σ = 5 and 13 [001] twist boundaries in Au with a resolution of 0.09 Angstrom or better. The reciprocal lattices of these boundaries were mapped out using synchrotron radiation. The atomic structures were obtained by testing model structures against the intensity observations with a chi square analysis. The boundary structure were modeled using polyhedra, including octahedra, special configurations of tetrahedra and Archimedian anti-prisms, interwoven together by the boundary symmetry. The results of this work point to the possibility of obtaining general rules for grain boundary structure based on X-ray diffraction observations that give the atomic positions with high resolution

  11. Crystallization and preliminary X-ray diffraction analysis of alanine racemase from Pseudomonas putida YZ-26

    International Nuclear Information System (INIS)

    Liu, Junlin; Feng, Lei; Shi, Yawei; Feng, Wei

    2012-01-01

    A recombinant alanine racemase from the Pseudomonas putida YZ-26, has been crystallized by the sitting-drop vapor-diffusion method and X-ray diffraction data were collected to 2.4 Å. A recombinant form of alanine racemase (Alr) from Pseudomonas putida YZ-26 has been crystallized by the sitting-drop vapour diffusion method. X-ray diffraction data were collected to 2.4 Å resolution. The crystals belong to the space group C222 1 , with unit-cell parameters a = 118.08, b = 141.86, c = 113.83 Å, and contain an Alr dimer in the asymmetric unit. The Matthews coefficient and the solvent content were calculated to be 2.8 Å 3 Da −1 and approximately 50%, respectively

  12. Electrochemical cell for in situ x-ray diffraction under ultrapure conditions

    DEFF Research Database (Denmark)

    Koop, T.; Schindler, W.; Kazimirov, A.

    1998-01-01

    within a few seconds. The oxygen level in the electrolyte is reduced by continuous N(2) flow to less than 0.2% compared to that of a fresh electrolyte. This can be done while rotating the cell by 360 degrees about the surface normal. The electrode potential is accurately measured at the position......An electrochemical cell has been developed for in situ x-ray diffraction from a working electrode under clean conditions equivalent to ultrahigh vacuum conditions of 5 x 10(-10) mbar. The substrate crystals can be prepared ex situ and transferred into the cell under protection of ultrapure water...... of the crystal using a Luggin capillary and a standard reference electrode. We demonstrate the performance of our cell by in situ synchrotron x-ray diffraction measurements on ultrathin Co layers electrodeposited on Cu(001) in an aqueous H(2)SO(4)/CoSO(4) solution. (C) 1998 American Institute of Physics....

  13. Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials.

    Science.gov (United States)

    Kulriya, P K; Singh, F; Tripathi, A; Ahuja, R; Kothari, A; Dutt, R N; Mishra, Y K; Kumar, Amit; Avasthi, D K

    2007-11-01

    An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN2) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90 MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C60 was used to test the sample cooling unit. It shows that the phase of the C60 film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T=255 K.

  14. Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials

    Science.gov (United States)

    Kulriya, P. K.; Singh, F.; Tripathi, A.; Ahuja, R.; Kothari, A.; Dutt, R. N.; Mishra, Y. K.; Kumar, Amit; Avasthi, D. K.

    2007-11-01

    An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN2) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C60 was used to test the sample cooling unit. It shows that the phase of the C60 film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T =255K.

  15. Quantitative strain analysis of surfaces and interfaces using extremely asymmetric x-ray diffraction

    International Nuclear Information System (INIS)

    Akimoto, Koichi; Emoto, Takashi

    2010-01-01

    Strain can reduce carrier mobility and the reliability of electronic devices and affect the growth mode of thin films and the stability of nanometer-scale crystals. To control lattice strain, a technique for measuring the minute lattice strain at surfaces and interfaces is needed. Recently, an extremely asymmetric x-ray diffraction method has been developed for this purpose. By employing Darwin's dynamical x-ray diffraction theory, quantitative evaluation of strain at surfaces and interfaces becomes possible. In this paper, we review our quantitative strain analysis studies on native SiO 2 /Si interfaces, reconstructed Si surfaces, Ni/Si(111)-H interfaces, sputtered III-V compound semiconductor surfaces, high-k/Si interfaces, and Au ion-implanted Si. (topical review)

  16. Applications of the Warren-Averbach method of X-ray diffraction line profile analysis

    International Nuclear Information System (INIS)

    Ichikawa, Rodrigo Uchida

    2013-01-01

    The objective of this work was to develop and implement a methodology of X-ray Line Profile Analysis (XLPA) for the study and determination of the mean crystallite sizes and microstrains in materials. A computer program was developed to speed up the treatment of diffraction peaks and perform the deconvolution utilizing the Stokes method to correct the instrumental contribution in the X-ray diffraction measurements. The XLPA methods used were the Scherrer, Williamson-Hall and Single-Line methods, which can be called real space methods, and the Fourier space method of Warren-Averbach. Furthermore, considering a mathematical modelling it was possible to calculate the crystallite size distribution, considering the log-normal distribution and spherical crystallites. It was possible to demonstrate the proposed theory can provide reliable results evaluating a dispersion parameter. The methodologies described above were applied in two distinct materials: in the alloy Zircaloy-4 and in ZnO. (author)

  17. Thermogravimetric and x-ray diffraction analyses of Luna-24 regolith samples

    International Nuclear Information System (INIS)

    Deshpande, V.V.; Dharwadkar, S.R.; Jakkal, V.S.

    1979-01-01

    Two samples of Luna-24 were analysed by X-ray diffraction and thermogravimetric (TG) techniques. The sample 24123.12 shows a weight loss of nearly 0.85 percent between 23O-440deg C and followed by 1.16 percent weight gain from 500 to 800deg C. The sample 23190.13 showed only a weight gain of about 1.5 percent from 5O0deg C to 900deg C. X-ray diffraction analyses show the presence of olivine, plagioclase, pigeonite, enstatite, and native iron in both the virgin samples. The heated samples, however, show that only the native iron got oxidized to iron oxide. The other constituents remain unaltered. (auth.)

  18. Correlated microradiography, X-ray microbeam diffraction and electron probe microanalysis of calcifications in an odontoma

    International Nuclear Information System (INIS)

    Aoba, T.; Yoshioka, C.; Yagi, T.

    1980-01-01

    Using microradiography, X-ray microbeam diffraction and electron probe microanalysis, a correlated morphologic and crystallographic study was performed on dysplastic enamel in a compound odontoma. The tumor was found in the lateral incisor-canine region of the left mandible of a 36-year-old woman. A conspicuous feature was the presence of hypomineralized areas, which were situated in the proximity of enamel surface and distinctly demarcated from the adjacent enamel. X-ray microbeam diffraction and electron microanalysis showed that these lesions have a lower crystallinity and a higher concentration of magnesium as compared with the adjacent enamel. In addition, the present study revealed the presence of two other types of calcifications: 1) calcified structures within the fissure or on the enamel surface, which include lacunae of varying size and which resemble a form of coronal cementum, and 2) spherical calcifications which may be an epithelial product. (author)

  19. Determination of diffusion profiles in thin film couples by means of X-ray-diffraction

    International Nuclear Information System (INIS)

    Wagendristel, A.

    1975-01-01

    An X-ray method for the determination of concentration profiles in thin film diffusion couples is presented. This method is based on the theory of Fourier analysis of X-ray diffraction profiles which is generalized to polycrystalline samples showing non-uniform lattice parameter. A Fourier synthesis of the concentration spectrum is possible when the influences of the particle size and the strain in the sample as well as the instrumental function are eliminated from the measured diffraction profile. This can be done by means of reference profiles obtained from layers of the diffusion components. Absorption of the radiation in the sample is negligible when diffusion couples of symmetrical sandwich structure are used. The method is tested experimentally in the system Au-Cu. (orig.) [de

  20. Investigation of mosaicity of epitaxic multilayers by the statistical theory of X-ray dynamical diffraction

    International Nuclear Information System (INIS)

    Li Ming; Mai Zhenhong; Li Jianhua; Li Chaorong; Cui Shufan

    1995-01-01

    Based on the statistical theory of X-ray dynamical diffraction for thin films, the mosaicity of three types of semiconductor epitaxic layers has been investigated by analyzing their rocking curves by the X-ray double-crystal diffraction method. It is shown that the statistical theory can provide quantitative information on the mosaicity of the epitaxic layers such as the mean size and the mean disorientation of mosaic blocks in the layers. Some misunderstandings in interpreting experimental data are cleared up by taking into account the effect of diffuse scattering. It is emphasized that attempts to obtain structural parameters of specimens from their rocking curves by means of the Takagi-Taupin equations for coherent fields only are not strictly correct since diffuse scattering causes additional changes in the tails of the rocking curves. (orig.)