WorldWideScience

Sample records for thin section ct

  1. Squalene aspiration pneumonia : thin-section CT and histopathologic findings

    International Nuclear Information System (INIS)

    Lee, Jin Seong; Gong, Gyung Yub; Lim, Tae Hwan

    1998-01-01

    The purpose of this study was to describe the thin-section computed tomography (CT) findings and histopathologic findings of squalene aspiration pneumonia. Thin-section CT scans were obtained from nine patients with proven exogenous lipoid pneumonia resulting from aspiration of squalene (derived from shark liver oil). The condition was diagnosed by biopsy (n=3), bronchoalveolar lavage(n=4), or sputum cytology and clinical history (n=2) of squalene use was confirmed in all patients. Specimens of transbronchial lung biopsy were also reviewed and compared with thin-section CT findings. On the basis of these results, we concluded that squalene aspiration pneumonia can be reliably diagnosed by thin-section CT findings particularly when the appropriate history is known. (author). 19 refs., 3 figs

  2. Thin-section CT of Cushing's disease

    International Nuclear Information System (INIS)

    Takahashi, Tatsuo; Kuwayama, Akio; Katoh, Tetsuo; Ichihara, Kaoru; Kageyama, Naoki; Nakamura, Koji.

    1983-01-01

    Using 1.5 mm contiguous sections with a GE CT/T 8800 scanner, we investigated the sellar regions of 22 cases of Cushing's diseases which had been diagnosed endocrinologically. Each sellar turcica was normal in size, and in only 5 cases were there significant findings on 2 mm-thick sellar-floor polytomography. Nine tumors appeared as regions of a hypodense area, and three tumors were diagnosed by indirect signs, for example, stalk deviation and diaphragmatic plane asymmetry. The other 10 cases, especially those previously operated on or irradiated, were diagnosed as falsely positive or negative. Because it is best of the microadenomas appear hypodense within the strongly contrast-enhanced anterior pituitary glands, it is better for scans to be obtained immediately after rapid intravenous contrast infusion. Hypodense areas of microadenomas are best demonstrated on direct coronal scans or reversed scans of 1.5 mm-thickness thin-slice sections. By these methods, microadenomas, if they are over 5-6 mm in diameter, can appear as hypodense. Sellar floor findings by means of thin-section CT were more sensitive than those of polytomography and had more advantages in local diagnosis. If the tumor were over 4 mm in diameter, local changes in the sellar floor could be demonstrated by thin-section CT, but by polytomography no changes in the sellar floor could be demonstrated until the tumor size reached 6 mm. (author)

  3. The use of thin-section high-resolution CT in pediatric pulmonary disease

    International Nuclear Information System (INIS)

    Hay, T.C.; Horgan, J.G.; Rumack, C.M.

    1989-01-01

    High-resolution thin-section CT of the chest was used successfully to characterize the extent of pulmonary disease. This paper reports on a study in which ten children with chronic lung disorders (including cystic fibrosis, reactive airway disease, and idiopathic disease) were evaluated to test the accuracy of the posteroanterior and lateral chest CT, with both thick (1 cm) and thin (1-3 mm) sections. Unsuspected bronchiectasis was established n two patients with reactive airway disease, and the extent of bronchiectasis in other patients was best defined on thin-section CT. Technique was crucial for an accurate study, and magnification views of each lung were useful. Thin-section CT of the chest was helpful in defining and localizing the extent of these pulmonary disorders

  4. Acute eosinophilic pneumonia: Thin-section CT findings in 29 patients

    International Nuclear Information System (INIS)

    Daimon, Tadahisa; Johkoh, Takeshi; Sumikawa, Hiromitsu; Honda, Osamu; Fujimoto, Kiminori; Koga, Takeharu; Arakawa, Hiroaki; Yanagawa, Masahiro; Inoue, Atsuo; Mihara, Naoki; Tomiyama, Noriyuki

    2008-01-01

    Purpose: To determine thin-section computed tomography (CT) characteristics of acute eosinophilic pneumonia (AEP). Materials and methods: Thin-section CT scans of 29 patients (14 males, 15 females; mean age, 26 ± 15 years; age range, 15-72 years) with AEP were included this retrospective study. The clinical diagnosis of AEP was established by Allen's criteria. Each thin-section CT was reviewed by two observers. Results: Bilateral areas with ground-glass attenuation were observed on thin-section CT in all patients. Areas of air-space consolidation were present in 16 (55%) of 29 patients. Poorly defined centrilobular nodules were present in 9 patients (31%). Interlobular septal thickening was present in 26 patients (90%). Thickening of bronchovascular bundles was present in 19 patients (66%). Pleural effusions were present in 23 patients (79%) (bilateral = 22, right side = 1, left side = 0). The predominant overall anatomic distribution was central in only 2 (7%) of 29 patients, peripheral in 9 patients (31%), and random in 18 patients (62%). The overall zonal predominance was upper in 4 patients (14%), lower in 8 patients (28%), and random in 17 patients (58%). Conclusion: CT findings in AEP patients consisted mainly of bilateral areas of ground-glass attenuation, interlobular septal thickening, thickening of bronchovascular bundles, and the presence of a pleural effusion without cardiomegaly. The most common overall anatomic distribution and zonal predominance of the abnormal CT findings were random

  5. Acute eosinophilic pneumonia: Thin-section CT findings in 29 patients

    Energy Technology Data Exchange (ETDEWEB)

    Daimon, Tadahisa [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, Yakushiji 3311-1, Shimotsuke, Tochigi 329-0498 (Japan)], E-mail: t-daimon@radiol.med.osaka-u.ac.jp; Johkoh, Takeshi [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: johkoh@sahs.med.osaka-u.ac.jp; Sumikawa, Hiromitsu [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: h-sumikawa@radiol.med.osaka-u.ac.jp; Honda, Osamu [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: ohonda@radiol.med.osaka-u.ac.jp; Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine, 67 Asahi-machi, Kurume 830-0011 (Japan)], E-mail: kimichan@med.kurume-u.ac.jp; Koga, Takeharu [Department of Medicine, Division of Respirology and Neurology, Kurume University School of Medicine, 67 Asahi-machi, Kurume 830-0011 (Japan)], E-mail: kogat@med.kurume-u.ac.jp; Arakawa, Hiroaki [Department of Radiology, Dokkyo University School of Medicine, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)], E-mail: arakawa@dokkyomed.ac.jp; Yanagawa, Masahiro [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Inoue, Atsuo [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: ainoue@radiol.med.osaka-u.ac.jp; Mihara, Naoki [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: nmihara@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki [Department of Radiology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan)], E-mail: tomiyama@radiol.med.osaka-u.ac.jp (and others)

    2008-03-15

    Purpose: To determine thin-section computed tomography (CT) characteristics of acute eosinophilic pneumonia (AEP). Materials and methods: Thin-section CT scans of 29 patients (14 males, 15 females; mean age, 26 {+-} 15 years; age range, 15-72 years) with AEP were included this retrospective study. The clinical diagnosis of AEP was established by Allen's criteria. Each thin-section CT was reviewed by two observers. Results: Bilateral areas with ground-glass attenuation were observed on thin-section CT in all patients. Areas of air-space consolidation were present in 16 (55%) of 29 patients. Poorly defined centrilobular nodules were present in 9 patients (31%). Interlobular septal thickening was present in 26 patients (90%). Thickening of bronchovascular bundles was present in 19 patients (66%). Pleural effusions were present in 23 patients (79%) (bilateral = 22, right side = 1, left side = 0). The predominant overall anatomic distribution was central in only 2 (7%) of 29 patients, peripheral in 9 patients (31%), and random in 18 patients (62%). The overall zonal predominance was upper in 4 patients (14%), lower in 8 patients (28%), and random in 17 patients (58%). Conclusion: CT findings in AEP patients consisted mainly of bilateral areas of ground-glass attenuation, interlobular septal thickening, thickening of bronchovascular bundles, and the presence of a pleural effusion without cardiomegaly. The most common overall anatomic distribution and zonal predominance of the abnormal CT findings were random.

  6. Artificial intelligence aiding the thin-section CT diagnosis of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Han, Dae Hee; Koh, Young Hwan; Seong, Chang Kyu; Kim, Ji Hoon; Choi, Young Ho; Kim, Jong Hyo; Chae, Young Moon; Lee, Yun Hee; Han, Heon

    2006-01-01

    We wanted to develop and test an artificial intelligence (AI) to assist physicians in making the thin-section CT diagnosis of diffuse pulmonary diseases. The AI was composed of knowledge bases (KB) of 12 diffuse pulmonary diseases and an inference engine (IE). The KB of a disease included both the inclusion criteria (IC) and the exclusion criteria (EC), which were the clinical or thin-section CT findings that were known to be present or absent in that particular disease, respectively. From imputing the clinical or thin-section CT findings by the operator who was reading the thin-section CT, AI instantly executed the following two steps. First, the IE eliminated all diseases from the list which the EC had for those particular findings. Next, from a list or remaining diseases, the AI selected those diseases having those findings in its IC to formulate the 1st-step differential diagnosis (DD1). For the differential diagnosis in the next step, the reader could choose one more clinical or thin-section CT finding from the new list: [(all the findings in the IC or EC of DD1)-(the findings in the IC common to all the DD1s)]. The reader could proceed even further if needed. The system was tested on 10 radiology residents who solved 24 problems (two problems for each of 12 diffuse pulmonary diseases) without and then with the aid of the AI. The scores were compared using the Wilcoxon signed rank test. An AI was made; it was composed of 280 rules (214 IC and 66 EC) and there interfaces (two for program management and another for problem solving). Contestants scored higher (ρ = 0.0078) using the AI (167 vs. 110 respectively), and they responded that they felt that the program was helpful in making decisions. AI appeared to be helpful in making thin-section CT diagnosis

  7. Artificial intelligence aiding the thin-section CT diagnosis of diffuse pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Han, Dae Hee; Koh, Young Hwan; Seong, Chang Kyu; Kim, Ji Hoon; Choi, Young Ho [Boramae Munincipal Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Jong Hyo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Chae, Young Moon [Yonsei University Graduate School of Public Heath, Seoul (Korea, Republic of); Lee, Yun Hee [The Graduate School of Imformation, Yonsei, Seoul (Korea, Republic of); Han, Heon [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2006-06-15

    We wanted to develop and test an artificial intelligence (AI) to assist physicians in making the thin-section CT diagnosis of diffuse pulmonary diseases. The AI was composed of knowledge bases (KB) of 12 diffuse pulmonary diseases and an inference engine (IE). The KB of a disease included both the inclusion criteria (IC) and the exclusion criteria (EC), which were the clinical or thin-section CT findings that were known to be present or absent in that particular disease, respectively. From imputing the clinical or thin-section CT findings by the operator who was reading the thin-section CT, AI instantly executed the following two steps. First, the IE eliminated all diseases from the list which the EC had for those particular findings. Next, from a list or remaining diseases, the AI selected those diseases having those findings in its IC to formulate the 1st-step differential diagnosis (DD1). For the differential diagnosis in the next step, the reader could choose one more clinical or thin-section CT finding from the new list: [(all the findings in the IC or EC of DD1)-(the findings in the IC common to all the DD1s)]. The reader could proceed even further if needed. The system was tested on 10 radiology residents who solved 24 problems (two problems for each of 12 diffuse pulmonary diseases) without and then with the aid of the AI. The scores were compared using the Wilcoxon signed rank test. An AI was made; it was composed of 280 rules (214 IC and 66 EC) and there interfaces (two for program management and another for problem solving). Contestants scored higher ({rho} = 0.0078) using the AI (167 vs. 110 respectively), and they responded that they felt that the program was helpful in making decisions. AI appeared to be helpful in making thin-section CT diagnosis.

  8. Pulmonary candidiasis after hematopoietic stem cell transplantation: thin-section CT findings.

    Science.gov (United States)

    Franquet, Tomás; Müller, Nestor L; Lee, Kyung S; Oikonomou, Anastasia; Flint, Julia D

    2005-07-01

    To retrospectively evaluate thin-section computed tomographic (CT) findings in hematopoietic stem cell transplant (ie, bone marrow transplant) patients with histopathologically proved pulmonary candidiasis. Ethical approval was obtained from the institutional review board of each of the three institutions; informed consent was not required. The study included 17 hematopoietic stem cell transplant recipients with proved pulmonary candidiasis. Histopathologic specimens were acquired at transbronchial biopsy (n = 8), open lung biopsy (n = 6), and autopsy (n = 3). The patients included seven men and 10 women (age range, 20-62 years; mean age, 37 years). The thin-section CT scans were retrospectively reviewed by two thoracic radiologists for the presence, appearance, and distribution of parenchymal abnormalities. Multiple nodules were present in 15 (88%) patients, including centrilobular nodules and tree-in-bud pattern in seven (41%) patients. Nodules were bilateral in 12 patients and unilateral in three. An associated halo of ground-glass opacity was identified in five (33%) patients. Nodules were the only CT finding in five patients (29%). Areas of air-space consolidation were identified in 11 (65%) patients. Areas of ground-glass opacity were seen in six (35%) of 17 patients and were always associated with other abnormalities. Other less common CT findings included pleural effusion (n = 3), thickening of the bronchial walls (n = 2), and cavitation (n = 1). The most common thin-section CT findings of pulmonary candidiasis in hematopoietic stem cell transplant patients are multiple bilateral nodular opacities often associated with areas of consolidation. Copyright RSNA, 2005

  9. Hematogenous candida pneumonia in major burn patients: plain chest radiograph and thin-section CT findings

    International Nuclear Information System (INIS)

    Kim, Hyo Heon; Lee, Eil Seong; Shim, Ya Seong; Kim, Ji Hun; Suh, Hong Kil; Cho, Sin Young; Kim, Dae Sun; Lee, Kil Woo; Kang, Ik Won

    1995-01-01

    To describe plain radiographic and thin-section CT findings of hematogenous candida pneumonia in major burn patients. We reviewed nine cases of hematogenous candida pneumonia in major burn patients who had positive blood culture for candida and findings of pneumonia on plain chest radiograph. On five of nine cases, thin-section CT was done. We evaluated retrospectively nine cases for onset, the pattern, distribution, and size of lesions on plain chest radiograph and thin-section CT. On plain chest radiograph, randomly distributed 2-10 mm nodules were seen in six cases(66%) and randomly distributed 10-15 mm consolidations in remaining three cases(33%). Lesion occurred in 11th to 75th post-burn day(average, 34th post-burn day). Other findings were cardiomegaly in three cases, atelectasis in three cases, and pulmonary edema in one case. Thin-section CT showed variable shaped subpleural nodules in all five cases. The size of nodules were 1-5 mm in two cases(40%) and 5-10 mm(60%) in three cases. Feeding vessel signs were seen in two cases. Other findings were atelectasis in three cases, cardiomegaly in three cases, ground-glass opacity and interlobular septal thickenings by pulmonary edema in two cases. Plain chest radiographic findings of hematogenous candida pneumonia in major burn patients are randomly distributed nodules or consolidations of variable size. Thin-section CT findings are variable shaped subpleural nodules less than 1 cm

  10. Mosaic pattern of lung attenuation on thin-section CT : review of 31 cases

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Hi; An, Jee Hyun; Lee, Kye Young; Jee, Young Koo; Lee, Young Seok [Dankook Univ. College of Medicine, Choan (Korea, Republic of)

    1998-07-01

    To correlate radiologic findings with clinical findings in patients with a mosaic pattern of lung attenuation, as seen on thin-section CT. Materials and Methods : Thirty-one cases in which a mosaic pattern of lung attenuation was detected on combined expiratory and inspiratory scans of thin-section CT were retrospectively analyzed. Cases involving infiltrative lung disease were excluded. Both thin-section CT and clinical findings we reanalyzed and the relationship between the extent of the area of hyperlucency -as seen on expiratory scan- and physiologic parameters was evaluated. The subjects were 10 men and 21 women ranged in age from 25 to 76 (mean 50)years. Results : Twenty-nine patients with small airway disease, [chronic bronchitis and/or bronchiolitis(n=11),bronchiectasis(n=8), bronchial asthma(n=8), mycoplasmic pneumonitis(n=1) and hypersensitive pneumonitis(n=1),] and two patients with pulmonary vascular disease, [chronic pulmonary thromboembolism(n=1) and stenosis of the left upper pulmonary artery(n=1)] were included in our study. Commonly associated thin-section CT findings in the cases involving small airway disease(n=29) were bronchial wall thickening(n=25), nodular opacity(n=25), bronchial and bronchiolar dilatation(n=20) and small branching opacity(n=16). These findings were not observed in two patients with pulmonary vascular disease, though bronchial wall thickening was seen in the patient with chronic pulmonary thromboembolism. At expiratory scan level, there was statistical correlation between FEV1/FVC and the number of pulmonary segments(r= 0.982, p<0.05), but no correlation between FEV1/FVC and the percentage area of hyperlucency(r=0.803, p>0.05). Conclusion: The mosaic pattern of lung attenuation seen on thin-section CT is indicative of various diseases, involving small airways such as bronchiolitis, bronchitis, bronchiectasis and bronchial asthma, and vascular lung disease. Bronchial wall thickening and nodular opacity can be associated with

  11. Non-contrast thin-section helical CT of urinary tract calculi in children

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Bates, Gregory D.; Bloom, David A.; Goodsitt, Mitchell M.

    2002-01-01

    Background: Non-contrast thin-section helical CT has gained acceptance for the diagnosis of urinary tract calculi in adults, but experience with the technique in children is limited. Purpose: To evaluate the utility of non-contrast thin section helical CT for the diagnosis of urinary tract calculi in children. Materials and methods: Radiology databases at three pediatric institutions were searched to identify all pediatric patients evaluated by ''renal stone'' protocol CT scans (no oral or intravenous contrast, scans covering the entire urinary tract obtained in helical mode with narrow collimation (< 5 mm)). CT scans were reviewed for the primary finding of urinary tract calculi, for secondary signs of acute urinary tract obstruction and for evidence of alternative diagnoses. Medical records were reviewed to determine clinical presentation and to confirm the eventual diagnosis. Results: One hundred thirty-seven scans of 113 children (mean age: 11.2 years) were studied. Thirty-eight of 94 examinations (40%) performed on 82 children for acute pain and/or hematuria showed ureteral calculi. Alternative diagnoses were suggested by CT on 16 scans (17%). Twenty-eight scans were performed on 10 asymptomatic children with known calculus disease confirming renal stone burden on 21 scans (75%) and persistent ureteral calculi on 6 scans (21%). Upper tract calculi were demonstrated on 10 of 15 scans (67%) performed to evaluate for calculi in patients with known non-calculus genitourinary tract abnormalities. Conclusions: Non-contrast thin section helical CT is a useful method to diagnose urinary tract calculi in children. Radiation dose in this retrospective study may exceed the lowest possible radiation dose for diagnostic accuracy. Further research is needed to optimize CT imaging parameters, while maintaining diagnostic accuracy and minimizing radiation dose. (orig.)

  12. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  13. Clinical and pulmonary thin-section CT findings in acute Klebsiella Pneumoniae pneumonia

    International Nuclear Information System (INIS)

    Okada, Fumito; Ando, Yumiko; Honda, Koichi; Nakayama, Tomoko; Kiyonaga, Maki; Ono, Asami; Tanoue, Shuichi; Maeda, Toru; Mori, Hiromu

    2009-01-01

    The aim of this study was to assess the clinical and pulmonary thin-section CT findings in patients with acute Klebsiella pneumoniae pneumonia. We retrospectively evaluated thin-section CT examinations performed between January 1991 and December 2007 from 962 patients with acute Klebsiella pneumoniae pneumonia. Seven hundred and sixty-four cases with concurrent infectious diseases were excluded. Thus, our study group comprised 198 patients (118 male, 80 female; age range 18-97 years, mean age 61.5). Underlying diseases and clinical findings were assessed. Parenchymal abnormalities were evaluated along with the presence of enlarged lymph nodes and pleural effusion. CT findings in patients with acute Klebsiella pneumoniae pneumonia consisted mainly of ground-glass attenuation (100%), consolidation (91.4%), and intralobular reticular opacity (85.9%), which were found in the periphery (96%) of both sides of the lungs (72.2%) and were often associated with pleural effusion (53%). The underlying conditions in patients with Klebsiella pneumoniae pneumonia were alcoholism or smoking habit. (orig.)

  14. Clinical and pulmonary thin-section CT findings in acute Klebsiella Pneumoniae pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Fumito [Oita University Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Oita (Japan); Oita University Faculty of Medicine, Department of Radiology, Oita (Japan); Ando, Yumiko; Honda, Koichi; Nakayama, Tomoko; Kiyonaga, Maki; Ono, Asami; Tanoue, Shuichi; Maeda, Toru; Mori, Hiromu [Oita University Faculty of Medicine, Department of Diagnostic and Interventional Radiology, Oita (Japan)

    2009-04-15

    The aim of this study was to assess the clinical and pulmonary thin-section CT findings in patients with acute Klebsiella pneumoniae pneumonia. We retrospectively evaluated thin-section CT examinations performed between January 1991 and December 2007 from 962 patients with acute Klebsiella pneumoniae pneumonia. Seven hundred and sixty-four cases with concurrent infectious diseases were excluded. Thus, our study group comprised 198 patients (118 male, 80 female; age range 18-97 years, mean age 61.5). Underlying diseases and clinical findings were assessed. Parenchymal abnormalities were evaluated along with the presence of enlarged lymph nodes and pleural effusion. CT findings in patients with acute Klebsiella pneumoniae pneumonia consisted mainly of ground-glass attenuation (100%), consolidation (91.4%), and intralobular reticular opacity (85.9%), which were found in the periphery (96%) of both sides of the lungs (72.2%) and were often associated with pleural effusion (53%). The underlying conditions in patients with Klebsiella pneumoniae pneumonia were alcoholism or smoking habit. (orig.)

  15. Disseminated dendriform pulmonary ossification associated with usual interstitial pneumonia: incidence and thin-section CT-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Sung; Chung, Myung Jin [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Seoul (Korea); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Seoul (Korea); Chung, Man Pyo [Sungkyunkwan University School of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Medicine, Seoul (Korea); Choi, Yong Soo [Sungkyunkwan University School of Medicine, Division of Thoracic Surgery, Seoul (Korea)

    2005-08-01

    The aim of this work was to assess the incidence of disseminated pulmonary dendriform ossification in usual interstitial pneumonia and nonspecific interstitial pneumonia, and to correlate thin-section computed tomography (CT) and histopathologic findings. We retrospectively reviewed thin-section CT and pathologic specimens of biopsy-proven usual interstitial pneumonia (75 patients, 57 men and 18 women, mean age 60 years, range 29-83 years) and nonspecific interstitial pneumonia (44 patients, 9 men and 35 women, mean age 55 years, range 20-73 years). On review of CT and histopathologic specimens, diffuse dendriform ossification was identified in five (four men and one woman, age range 41-68 years, mean 58 years) of 75 patients (6.7%) with usual interstitial pneumonia. It was not seen in any of 44 patients with nonspecific interstitial pneumonia. With thin-section CT (osteoporosis window; window width 818, level 273), disseminated dendriform pulmonary ossification was detected as multiple tiny calcifications in bibasilar subpleural lungs (100% sensitive and 100% specific when compared with histopathologic findings as the gold standard). The thin-section CT finding of multiple tiny calcifications in bibasilar subpleural lungs might be of some help in the differential diagnosis between usual interstitial pneumonia and nonspecific interstitial pneumonia, considering they were not seen in any patients with nonspecific interstitial pneumonia (0%, 0/44) in our series. (orig.)

  16. Disseminated dendriform pulmonary ossification associated with usual interstitial pneumonia: incidence and thin-section CT-pathologic correlation

    International Nuclear Information System (INIS)

    Kim, Tae Sung; Chung, Myung Jin; Han, Joungho; Chung, Man Pyo; Choi, Yong Soo

    2005-01-01

    The aim of this work was to assess the incidence of disseminated pulmonary dendriform ossification in usual interstitial pneumonia and nonspecific interstitial pneumonia, and to correlate thin-section computed tomography (CT) and histopathologic findings. We retrospectively reviewed thin-section CT and pathologic specimens of biopsy-proven usual interstitial pneumonia (75 patients, 57 men and 18 women, mean age 60 years, range 29-83 years) and nonspecific interstitial pneumonia (44 patients, 9 men and 35 women, mean age 55 years, range 20-73 years). On review of CT and histopathologic specimens, diffuse dendriform ossification was identified in five (four men and one woman, age range 41-68 years, mean 58 years) of 75 patients (6.7%) with usual interstitial pneumonia. It was not seen in any of 44 patients with nonspecific interstitial pneumonia. With thin-section CT (osteoporosis window; window width 818, level 273), disseminated dendriform pulmonary ossification was detected as multiple tiny calcifications in bibasilar subpleural lungs (100% sensitive and 100% specific when compared with histopathologic findings as the gold standard). The thin-section CT finding of multiple tiny calcifications in bibasilar subpleural lungs might be of some help in the differential diagnosis between usual interstitial pneumonia and nonspecific interstitial pneumonia, considering they were not seen in any patients with nonspecific interstitial pneumonia (0%, 0/44) in our series. (orig.)

  17. Bronchiolitis obliterans syndrome: thin-section CT diagnosis of obstructive changes in infants and young children after lung transplantation.

    Science.gov (United States)

    Lau, D M; Siegel, M J; Hildebolt, C F; Cohen, A H

    1998-09-01

    To characterize the thin-section computed tomographic (CT) appearance of bronchiolitis fibrosa obliterans syndrome in infants and young children after lung transplantation. Thin-section CT studies in six patients with bronchiolitis obliterans syndrome (age range, 2 months to 5 1/2 years) and in 15 control patients without obstructive airway disease (age range, 2 months to 7 years) who underwent bilateral lung transplantation were retrospectively reviewed. The thin-section CT scans were obtained during quiet sleep at a median of 24 months (range, 6-36 months) after transplantation. The CT studies were evaluated for mosaic perfusion, bronchial dilatation, bronchial wall thickening, and mucous plugging Final diagnoses in all patients were based pulmonary function test results. Thin-section CT findings in the six patients with clinically proved bronchiolitis obliterans syndrome were mosaic perfusion in five (83%) bronchial dilation in three (50%), and bronchial wall thickening in one (17%). Of the 15 control patients with normal pulmonary function test results, six (40%) had mosaic perfusion; none had bronchial dilatation or bronchial wall thickening. Mucous plugging was not seen in either group. Only the association of bronchial dilatation with bronchiolitis obliterans syndrome was significant (P = .02). Infants and young children with bronchiolitis obliterans syndrome after lung transplantation are more likely to have CT abnormalities than those with normal pulmonary function test results.

  18. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    International Nuclear Information System (INIS)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo

    1997-01-01

    The purpose of this study was 1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and 2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20

  19. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    Science.gov (United States)

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  20. Thin-section chest CT findings in systemic lupus erythematosus with antiphospholipid syndrome: A comparison with systemic lupus erythematosus without antiphospholipid syndrome

    International Nuclear Information System (INIS)

    Oki, Hodaka; Aoki, Takatoshi; Saito, Kazuyoshi; Yamashita, Yoshiko; Hanamiya, Mai; Hayashida, Yoshiko; Tanaka, Yoshiya; Korogi, Yukunori

    2012-01-01

    Purpose: To assess thin-section chest CT findings in systemic lupus erythematosus (SLE) with antiphospholipid syndrome (APS), in comparison with SLE without APS. Materials and methods: We retrospectively reviewed the medical records and thin-section CT findings of 17 consecutive patients with an established diagnosis of SLE with APS, comparing with 37 consecutive SLE patients without APS, between 2004 and 2008, and patients who had other autoimmune disease, such as Sjögren syndrome, were excluded. No significant differences were seen between the two groups in age, gender, smoking habits, or history of steroid pulse and biological therapy. CT images of 2 mm thickness obtained with a 16- or 64-detector row CT were retrospectively evaluated by two radiologists in consensus on ultra high-resolution gray-scale monitors. Results: The frequency of thin-section CT abnormalities was higher in SLE with APS group (82%) than in SLE without APS group (43%). Ground-glass opacity (59%), architectural distortion (47%), reticulation (41%), enlarged peripheral pulmonary artery (29%), and mosaic attenuation (29%) were significantly more common in the SLE with APS group than in the SLE without APS group (Fisher's exact test, p < 0.01). Conclusion: SLE patients with APS have increased prevalence of thin-section chest CT abnormalities than those without APS.

  1. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W. Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter

  2. Fungus infection in immunocompromised rabbits: correlation of thin-section CT findings and histopathology

    International Nuclear Information System (INIS)

    Xue Feng; Liu Shiyuan; Xie Lixuan; Liu Kai; Zhang Jian; Chen Yousan; Li Huimin; He Jin

    2009-01-01

    Objective: To compare the thin-section CT findings of pulmonary candidiasis, aspergillosis and cryptococcosis with histopathology in immunocompromised rabbits and improve the diagnostic accuracy of fungus infection. Methods: Healthy New Zealand white rabbits were used for immunocompromised animal models. Thin-section CT scan was performed before and 2, 4, 6, 8, 10, 12, 14 d after inoculation. The pattern and distribution of the pulmonary abnormalities were retrospectively assessed by two thoracic radiologists and compared with histopathology. The granulocyte count was compared before and after administration of immunosuppressive agents. The paired t test, chi square test and the Fisher's exact test were used for the statistics. Results: Fourteen rabbits had candidiasis, 16 rabbits had eryptococcosis, 15 rabbits had aspergillosis. The granulocyte counts before and after administration of immunosuppressive agents were (2.91±0.92) and (0.35±0.19) x 10 9 /L respectively in candidiasis group, there was a significant difference (t=12.484, P 9 /L in aspergillosis group, there was a significant difference (t=5.792, P 9 /L in cryptococcosis group, there was a significant difference (t=8.199, P 0.05). Ground glass opacity (GGO) and consolidation were the two most common findings in immunocompromised rabbits with three fungus infections, areas of GGO was correlated with the congestion, hemorrhage, inflammatory cell infiltration and interstitial hyperplasia in pathology. Consolidation was correlated with the severe congestion, hemorrhage, inflammatory cell infiltration, interstitial hyperplasia, necrosis and vascular embolism in pathology. Conclusion: GGO and consolidation are the two most common findings of fungus infections in immunocompromised animal models and thin-section CT findings can reflect the pathological changes. (authors)

  3. Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients.

    LENUS (Irish Health Repository)

    O'Connor, Owen J

    2010-12-01

    To develop low-dose thin-section computed tomographic (CT) protocols for assessment of cystic fibrosis (CF) in pediatric patients and determine the clinical usefulness thereof compared with chest radiography.

  4. Bubble-like appearances are characteristic thin-section CT findings of adenocarcinoma

    International Nuclear Information System (INIS)

    Kojima, Yoko; Saito, Haruhiro; Ito, Hiroyuki

    2008-01-01

    Adenocarcinomas are often diagnosed as old inflammatory lesions which are sometimes overlooked. Some of these adenocarcinomas display characteristic thin-section computed tomography (TS-CT) findings. We reported on these bubble-like appearances (BLA). We studied the BLA characteristics of adenocarcinomas. We reviewed the TS-CT findings of 17 (6 men, 11 women) cases of adenocarcinoma with bubble-like appearances. All 17 patients had undergone surgery between August 2003 and March 2007. We studied correlations between the TS-CT findings, the pathological findings and the clinical characteristics. The average tumor diameter was 35.4 mm. The definition of BLA is; having a irregular shape with straight margins, peripheral ground-glass opacity (GGO), dilated air bronchograms (more than 3), prominent pleural indentation. The pathological characteristics of tumors with BLA were; peripheral bronchioloalveolar cell carcinoma (BAC) patterns, almost total collapse (about 80% of the tumor area), and several ectatic small bronchi. Six cases were initially overlooked, because the TS-CT findings appeared as old inflammation. The average tumor doubling time was 1167 days. After resection, there have been no recurrences. On TS-CT images, BLA type adenocarcinomas appear as irregular in shape and they have a very slow doubling time. These types of lesions require careful attention because they are often diagnosed as old inflammatory scarring. (author)

  5. Localized thin-section CT with radiomics feature extraction and machine learning to classify early-detected pulmonary nodules from lung cancer screening

    Science.gov (United States)

    Tu, Shu-Ju; Wang, Chih-Wei; Pan, Kuang-Tse; Wu, Yi-Cheng; Wu, Chen-Te

    2018-03-01

    Lung cancer screening aims to detect small pulmonary nodules and decrease the mortality rate of those affected. However, studies from large-scale clinical trials of lung cancer screening have shown that the false-positive rate is high and positive predictive value is low. To address these problems, a technical approach is greatly needed for accurate malignancy differentiation among these early-detected nodules. We studied the clinical feasibility of an additional protocol of localized thin-section CT for further assessment on recalled patients from lung cancer screening tests. Our approach of localized thin-section CT was integrated with radiomics features extraction and machine learning classification which was supervised by pathological diagnosis. Localized thin-section CT images of 122 nodules were retrospectively reviewed and 374 radiomics features were extracted. In this study, 48 nodules were benign and 74 malignant. There were nine patients with multiple nodules and four with synchronous multiple malignant nodules. Different machine learning classifiers with a stratified ten-fold cross-validation were used and repeated 100 times to evaluate classification accuracy. Of the image features extracted from the thin-section CT images, 238 (64%) were useful in differentiating between benign and malignant nodules. These useful features include CT density (p  =  0.002 518), sigma (p  =  0.002 781), uniformity (p  =  0.032 41), and entropy (p  =  0.006 685). The highest classification accuracy was 79% by the logistic classifier. The performance metrics of this logistic classification model was 0.80 for the positive predictive value, 0.36 for the false-positive rate, and 0.80 for the area under the receiver operating characteristic curve. Our approach of direct risk classification supervised by the pathological diagnosis with localized thin-section CT and radiomics feature extraction may support clinical physicians in determining

  6. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nishio, Mizuho [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Koyama, Hisanobu [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki [Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Seki, Shinichiro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Tsubakimoto, Maho [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nakagami-Gun, Okinawa (Japan); Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2014-02-15

    Purpose: To prospectively and directly compare oxygen-enhanced (O{sub 2}-enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O{sub 2}-enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O{sub 2}-enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O{sub 2}-enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD.

  7. Oxygen-enhanced MRI for patients with connective tissue diseases: Comparison with thin-section CT of capability for pulmonary functional and disease severity assessment

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Seki, Shinichiro; Tsubakimoto, Maho; Sugimura, Kazuro

    2014-01-01

    Purpose: To prospectively and directly compare oxygen-enhanced (O 2 -enhanced) MRI with thin-section CT for pulmonary functional loss and disease severity assessment in connective tissue disease (CTD) patients with interstitial lung disease (ILD). Materials and methods: Thin-section CT, O 2 -enhanced MRI, pulmonary function test and serum KL-6 were administered to 36 CTD patients with ILD (23 men, 13 women; mean age: 63.9 years) and nine CTD patients without ILD (six men, and three women; mean age: 62.0 years). A relative-enhancement ratio (RER) map was generated from O 2 -enhanced MRI and mean relative enhancement ratio (MRER) for each subject was calculated from all ROI measurements. CT-assessed disease severity was evaluated with a visual scoring system from each of the thin-section CT data. MRER and CT-assessed disease severities of CTD patients with and without ILD were then statistically compared. To assess capability for pulmonary functional loss and disease severity assessment in CTD patients, correlations of MRER and CT-assessed disease severity with pulmonary functional parameters and serum KL-6 in all subjects were statistically determined. Results: MRER and CT-assessed disease severity showed significant differences between CTD patients with (MRER: 0.15 ± 0.08, CT-assessed disease severity: 13.0 ± 7.4%) and without ILD (MRER: 0.25 ± 0.06, p = 0.0011; CT-assessed disease severity: 1.6 ± 1.6%, p < 0.0001). MRER and CT-assessed disease severity correlated significantly with pulmonary functional parameters and serum KL-6 in all subjects (0.61 ≤ r ≤ 0.79, p < 0.05). Conclusion: O 2 -enhanced MRI was found to be as useful as thin-section CT for pulmonary functional loss and disease severity assessment of CTD patients with ILD

  8. The thin-section CT, pathological and clinical findings of peripheral small squamous cell lung carcinomas

    International Nuclear Information System (INIS)

    Yamamoto, Takahito; Saito, Haruhiro; Kondo, Tetsuro

    2010-01-01

    We analyzed thin-section CT, pathological, and clinical findings of peripheral lung squamous cell carcinomas, with diameters of less than 20 mm and compared these findings with solid type adenocarcinomas. CT findings of polygonal shapes, notches, pleural thickness, and cavities are more frequently found in squamous cell carcinomas than in adenocarcinomas. The pathological types can be classified in two groups: Solid types, Scirrhous types. The 5 year survival rate after resection is 64.5%, which is poorer than survival rate for solid type adenocarcinomas. It is vital to diagnose and treat peripheral squamous cell carcinomas as early as possible. (author)

  9. Interlobar fissures involvement by lung cancer. Evaluation with thin-section computed tomography images

    International Nuclear Information System (INIS)

    Kato, Yuji; Yamada, Kouzo; Nomura, Ikuo; Noda, Kazumasa; Ishiwa, Naoki; Maehara, Takamitsu; Kameda, Youichi

    1998-01-01

    Pleural involvement of interlobar fissure by a tumor is one of the most important factors in the clinical diagnosis of lung cancer. A positive finding of incomplete interlobar fissure of the lung influences not only the surgical procedure but also the prognosis. The aim of this retrospective study was to investigate the usefulness of thin-section computed tomography (CT) compared with conventional CT in the detection of pleural invasion of the interlobar fissure by lung cancer or incomplete interlobar fissure, and the results of surgery, according to the involvement of the pleural surface. We reviewed 90 patients whose tumors were adjacent to the interlobar fissure of the lung through conventional CT scans and subsequent thoracotomy. A comparison of diagnoses based on the findings of thin-section CT and pathologic examination showed that thin-section CT was 94% accurate for pleural invasion of the interlobar fissure, and 100% for incomplete interlobar fissure. Conventional CT, however, was only 63% accurate for pleural invasion of the interlobar fissure and 31% for incomplete interlobar fissure. This leads us to conclude that thin-section CT is helpful in the accurate evaluation of pleural invasion of the interlobar fissure and in the findings of incomplete interlobar fissure in lung cancer for patients in whom tumors are adjacent to the interlobar fissure on conventional CT findings. (author)

  10. Evaluation of benign pulmonary lesions less than 20 mm in diameter by thin-section computed tomography

    International Nuclear Information System (INIS)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro

    1997-01-01

    To establish diagnostic criteria for small solitary pulmonary nodules, the findings of thin-section computed tomography (CT) were compared with pathological findings. We evaluated thin-section CT images and compared them with pathological findings in 23 specimens of resected benign lesions less than 20 mm in diameter located in the peripheral region. The thin-section CT images were reconstructed using 2 mm thick sections taken by TCT-900S, HELIX (Toshiba, Tokyo) and were examined with two different windows and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT findings. The thin-section CT images were classified into two types; solid and air-containing types. The former consisted of benign pulmonary tumors, granulomas and some focal fibrosis, while the latter all consisted of focal fibrosis. Both types were difficult to distinguish from peripheral lung cancer based only on margin analysis of the lesion, but analysis of how pulmonary vessels relate to the lesion can allow benign pulmonary lesions to be distinguished from peripheral lung cancer. (author)

  11. Acute appendicitis: sensitivity, specificity and diagnostic accuracy of thin-section contrast-enhanced CT findings

    International Nuclear Information System (INIS)

    Lee, Ji Yon; Choi, Dong Il; Park, Hae Won; Lee, Young Rae; Kook, Shin Ho; Kwang, Hyon Joo; Kim, Seung Kwon; Chung, Eun Chul

    2002-01-01

    To assess the sensitivity, specificity, and diagnostic accuracy of individual contrast-enhanced helical CT findings of acute appendicitis. We retrospectively reviewed the appendiceal helical CT scans, obtained after intravenous contrast administration (abdomen; 7-mm collimation, abdominopelvic junction; 5-mm collimation), of 50 patients with surgically proven acute appendicitis and 112 with alternative diagnoses. The following parameters were analysed by three radiologists: enlarged appendix (>6 mm in diameter), appendiceal wall thickening, appendiceal wall enhancement, no identification of the appendix, appendicolith(s), (appendiceal) intraluminal air, abscess, lymphadenopathy, terminal ileal wall thickening, focal cecal apical thickening, focal colonic wall thickening, and segmental colonic wall thickening. The CT findings of acute appendicitis that statistically distinguished it from alternative diagnoses were an enlarged appendix (sensitivity; 92%, specificity; 93%, diagnostic accuracy; 93%), appendiceal wall thickening (for these three parameters: 68%, 96% and 88%, respectively), periappendiceal fat stranding (90%, 79%, 82%), appendiceal wall enhancement (72%, 86%, 82%), appendicolith (16%, 100%, 74%), and focal cecal apical thickening (14%, 100%, 74%) (for each, p<0305). On thin-section contrast-enhanced helical CT, an enlarged appendix and periappendiceal fat stranding were found in 90% or more patients with acute appendicitis. Appendiceal wall thickening and enhancement were alearly demonstrated and significant findings for diagnosis. Less common but specific findings include appendicolith, focal cecal apical thickening and intramural air, can also help us establish a diagnosis of acute appendicitis

  12. Thin-section spiral CT evaluation of morphologic effects of aging lung in asymptomatic adult subjects

    International Nuclear Information System (INIS)

    Li Kuncheng; Liu Jian; Yang Yanhui; Yao Xinyu; Yin Jianguo; Wang Shiwen; He Zuoxiang

    2006-01-01

    Objective: To evaluate the imaging signs of aging lung in asymptomatic adult subjects by using thin-section spiral CT, and analyze the correlation between the signs and the age of examined cases, as well as probe their clinical application value. Methods: One hundred and six healthy adult subjects were divided into 3 groups: 30 to 44 years (n=31), 45 to 59 years (n=30), and over 60 years (n=45), and all the subjects underwent thin-section spiral CT scans in the upper lung field, the middle lung field and the lower lung field. The evaluation indices included the lung interstitium changes, emphysematous changes, mosaic perfusion, dependent density difference, and pleural thickenning. According to the relative score standard, the above-mentioned indices were totally calculated and converted into the score value. The data were statistically processed with SPSS for Windows. Results: Among the three groups, there were remarkable differences in the indices including the lung interstitium changes, emphysematous changes, and mosaic perfusion, respectively (χ 2 =8.10, 9.73, 15.54, P 2 =3.66, 3.24, P> 0.05). The score values had a significant positive correlation with the age (r=0.709, P<0.01). Conclusion: The signs including the lung interstitium changes, emphysematous changes, mosaic perfusion, the dependent density difference, and pleural thickenning can be found in asymptomatic subjects, and they become prominent as the age increases. HRCT is one of the most important methods for evaluating the early signs of the senile lung. (authors)

  13. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning.

    Science.gov (United States)

    Gee, Carole T

    2013-11-01

    As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction.

  14. Bronchus-associated lymphoid tissue (BALT) lymphoma of the lung showing mosaic pattern of inhomogeneous attenuation on thin-section CT: a case report

    International Nuclear Information System (INIS)

    Lee, In Jae; Kim, Sung Hwan; Koo, Soo Hyun; Kim, Hyun Beom; Hwang, Dae Hyun; Lee, Kwan Seop; Lee, Yul; Jang, Kee Taek; Kim, Duck Hwan

    2000-01-01

    The authors present a case of histologically proven bronchus-associated lymphoid tissue (BALT) lymphoma of the lung in a patient with primary Sjogren's syndrome that manifested on thin-section CT scan as a mosaic pattern of inhomogeneous attenuation due to mixed small airway and infiltrative abnormalities

  15. Applying microCT and 3D visualization to Jurassic silicified conifer seed cones: A virtual advantage over thin-sectioning1

    Science.gov (United States)

    Gee, Carole T.

    2013-01-01

    • Premise of the study: As an alternative to conventional thin-sectioning, which destroys fossil material, high-resolution X-ray computed tomography (also called microtomography or microCT) integrated with scientific visualization, three-dimensional (3D) image segmentation, size analysis, and computer animation is explored as a nondestructive method of imaging the internal anatomy of 150-million-year-old conifer seed cones from the Late Jurassic Morrison Formation, USA, and of recent and other fossil cones. • Methods: MicroCT was carried out on cones using a General Electric phoenix v|tome|x s 240D, and resulting projections were processed with visualization software to produce image stacks of serial single sections for two-dimensional (2D) visualization, 3D segmented reconstructions with targeted structures in color, and computer animations. • Results: If preserved in differing densities, microCT produced images of internal fossil tissues that showed important characters such as seed phyllotaxy or number of seeds per cone scale. Color segmentation of deeply embedded seeds highlighted the arrangement of seeds in spirals. MicroCT of recent cones was even more effective. • Conclusions: This is the first paper on microCT integrated with 3D segmentation and computer animation applied to silicified seed cones, which resulted in excellent 2D serial sections and segmented 3D reconstructions, revealing features requisite to cone identification and understanding of strobilus construction. PMID:25202495

  16. Bronchus-associated lymphoid tissue (BALT) lymphoma of the lung showing mosaic pattern of inhomogeneous attenuation on thin-section CT: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Jae; Kim, Sung Hwan; Koo, Soo Hyun; Kim, Hyun Beom; Hwang, Dae Hyun; Lee, Kwan Seop; Lee, Yul; Jang, Kee Taek; Kim, Duck Hwan [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)

    2000-09-01

    The authors present a case of histologically proven bronchus-associated lymphoid tissue (BALT) lymphoma of the lung in a patient with primary Sjogren's syndrome that manifested on thin-section CT scan as a mosaic pattern of inhomogeneous attenuation due to mixed small airway and infiltrative abnormalities.

  17. Differentiation of bacterial and non-bacterial community-acquired pneumonia by thin-section computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Isao [Department of Respiratory Medicine, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602 (Japan); Department of Respiratory Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: isaoito@kuhp.kyoto-u.ac.jp; Ishida, Tadashi [Department of Respiratory Medicine, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602 (Japan)], E-mail: ishidat@kchnet.or.jp; Togashi, Kaori [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: ktogashi@kuhp.kyoto-u.ac.jp; Niimi, Akio [Department of Respiratory Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: niimi@kuhp.kyoto-u.ac.jp; Koyama, Hiroshi [General Internal Medicine, National Hospital Organization Kyoto Medical Center, 1-1 Fukakusa-Mukohatacho, Fushimi-ku, Kyoto 612-8555 (Japan)], E-mail: hkoyama-kyt@umin.ac.jp; Ishimori, Takayoshi [Department of Radiology, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki 710-8602 (Japan)], E-mail: ti10794@kchnet.or.jp; Kobayashi, Hisataka [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan); Molecular Imaging Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Building 10, Room 1B40, MSC1088, 10 Center Drive, Bethesda, MD 20892-1088 (United States)], E-mail: kobayash@mail.nih.gov; Mishima, Michiaki [Department of Respiratory Medicine, Kyoto University, 54 Shogoin-kawaharacho, Sakyo-ku, Kyoto 606-8507 (Japan)], E-mail: mishima@kuhp.kyoto-u.ac.jp

    2009-12-15

    Background and objective: The management of community-acquired pneumonia (CAP) depends, in part, on the identification of the causative agents. The objective of this study was to determine the potential of thin-section computed tomography (CT) in differentiating bacterial and non-bacterial pneumonia. Patients and methods: Thin-section CT studies were prospectively examined in hospitalized CAP patients within 2 days of admission, followed by retrospective assessment by two pulmonary radiologists. Thin-section CT findings on the pneumonias caused by each pathogen were examined, and two types of pneumonias were compared. Using multivariate logistic regression analyses, receiver operating characteristic (ROC) curves were produced. Results: Among 183 CAP episodes (181 patients, 125 men and 56 women, mean age {+-} S.D.: 61.1 {+-} 19.7) examined by thin-section CT, the etiologies of 125 were confirmed (94 bacterial pneumonia and 31 non-bacterial pneumonia). Centrilobular nodules were specific for non-bacterial pneumonia and airspace nodules were specific for bacterial pneumonia (specificities of 89% and 94%, respectively) when located in the outer lung areas. When centrilobular nodules were the principal finding, they were specific but lacked sensitivity for non-bacterial pneumonia (specificity 98% and sensitivity 23%). To distinguish the two types of pneumonias, centrilobular nodules, airspace nodules and lobular shadows were found to be important by multivariate analyses. ROC curve analysis discriminated bacterial pneumonia from non-bacterial pneumonia among patients without underlying lung diseases, yielding an optimal point with sensitivity and specificity of 86% and 79%, respectively, but was less effective when all patients were analyzed together (70% and 84%, respectively). Conclusion: Thin-section CT examination was applied for the differentiation of bacterial and non-bacterial pneumonias. Though showing some potential, this examination at the present time would

  18. Differentiation of bacterial and non-bacterial community-acquired pneumonia by thin-section computed tomography

    International Nuclear Information System (INIS)

    Ito, Isao; Ishida, Tadashi; Togashi, Kaori; Niimi, Akio; Koyama, Hiroshi; Ishimori, Takayoshi; Kobayashi, Hisataka; Mishima, Michiaki

    2009-01-01

    Background and objective: The management of community-acquired pneumonia (CAP) depends, in part, on the identification of the causative agents. The objective of this study was to determine the potential of thin-section computed tomography (CT) in differentiating bacterial and non-bacterial pneumonia. Patients and methods: Thin-section CT studies were prospectively examined in hospitalized CAP patients within 2 days of admission, followed by retrospective assessment by two pulmonary radiologists. Thin-section CT findings on the pneumonias caused by each pathogen were examined, and two types of pneumonias were compared. Using multivariate logistic regression analyses, receiver operating characteristic (ROC) curves were produced. Results: Among 183 CAP episodes (181 patients, 125 men and 56 women, mean age ± S.D.: 61.1 ± 19.7) examined by thin-section CT, the etiologies of 125 were confirmed (94 bacterial pneumonia and 31 non-bacterial pneumonia). Centrilobular nodules were specific for non-bacterial pneumonia and airspace nodules were specific for bacterial pneumonia (specificities of 89% and 94%, respectively) when located in the outer lung areas. When centrilobular nodules were the principal finding, they were specific but lacked sensitivity for non-bacterial pneumonia (specificity 98% and sensitivity 23%). To distinguish the two types of pneumonias, centrilobular nodules, airspace nodules and lobular shadows were found to be important by multivariate analyses. ROC curve analysis discriminated bacterial pneumonia from non-bacterial pneumonia among patients without underlying lung diseases, yielding an optimal point with sensitivity and specificity of 86% and 79%, respectively, but was less effective when all patients were analyzed together (70% and 84%, respectively). Conclusion: Thin-section CT examination was applied for the differentiation of bacterial and non-bacterial pneumonias. Though showing some potential, this examination at the present time would not

  19. Short linear shadows connecting pulmonary segmental arteries to oblique fissures in volumetric thin-section CT images: comparing CT, micro-CT and histopathology

    International Nuclear Information System (INIS)

    Guan, Chun-Shuang; Ma, Da-Qing; Chen, Jiang-Hong; Chen, Bu-Dong; Cui, Dun; Zhang, Yan-Song; Liu, Wei-Hua

    2016-01-01

    To retrospectively evaluate short linear shadows connecting pulmonary segmental arteries to oblique fissures in thin-section CT images and determine their anatomical basis. CT scanning was performed on 108 patients and 11 lung specimens with no lung diseases around the oblique fissures or hilar. Two radiologists evaluated the imaging. The parameters included length, thickness of short linear shadows, pulmonary segmental artery variations, and traction interlobar fissures, etc. The short linear shadows were not related to sex, age, or smoking history. The lengths of the short linear shadows were generally within 10 mm. The thicknesses of the short linear shadows ranged from 1 to 2 mm. Of the patients, 26.9 % showed pulmonary segmental artery variations; 66.7 % of short linear shadows pulled oblique fissures. In three-dimensional images, the short linear shadows appeared as arc planes, with one side edge connected to the oblique fissure, one side edge connected to a pulmonary segmental artery. On the tissue slices, the short linear shadow exhibited a band structure composed of connective tissues, small blood vessels, and small lymphatic vessels. Short linear shadows are a type of normal intrapulmonary membranes and can maintain the integrity of the oblique fissures and hilar structure. (orig.)

  20. Thin-section CT imaging that correlates with pulmonary function tests in obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki, E-mail: arakawa@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine (Japan); Fukushima, Yasutugu [Department of Pulmonary Medicine and Clinical Immunology, Dokkyo Medical University (Japan); Kaji, Yasushi [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)

    2011-11-15

    Purpose: The purpose of this study was to identify independent CT findings that correlated with pulmonary function tests (PFTs) in patients with obstructive airway diseases. Materials and methods: Sixty-eight patients with obstructive airway disease and 29 normal subjects (mean age, 52 years; 36 men and 61 women) underwent inspiratory and expiratory thin-section CT and PFTs. Patient with obvious emphysema was excluded. Two radiologists independently reviewed the images and semi-quantitatively evaluated lung attenuation (mosaic perfusion, air trapping) and airway abnormalities (extent and severity of bronchial wall thickening and bronchiectasis, bronchiolectasis or centrilobular nodules, mucous plugging). Univariate, multivariate and receiver operating characteristic (ROC) analyses were performed with CT findings and PFTs. Results: Forty-two patients showed obstructive PFTs, 26 symptomatic patients showed near-normal PFTs. On univariate analysis, air trapping and bronchial wall thickening showed highest correlation with obstructive PFTs such as FEV1.0/FVC, MMEF and FEF75 (r ranged from -0.712 to -0.782; p < 0.001), while mosaic perfusion and mucous plugging showed moderate correlation, and bronchiectasis, bronchiolectasis and nodules showed the least, but significant, correlation. Multiple logistic analyses revealed air trapping and bronchial wall thickening as the only significant independent determinants of obstructive PFTs. ROC analysis revealed the cut-off value of air trapping for obstructive PFTs to be one-third of whole lung (area under curve, 0.847). Conclusions: Our study confirmed air trapping and bronchial wall thickening are the most important observations when imaging obstructive PFTs. The cut-off value of air trapping for identifying obstructive PFTs was one-third of lung irrespective of inspiratory CT findings.

  1. Ground-glass nodule on thin-section CT: Differentiation among adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma

    International Nuclear Information System (INIS)

    Lee, Man Ho; Ryu, Dae Shick; Kim, Do Young; Ahn, Jae Hong; Choi, Soo Jung; Gang, Gil Hyeon; Yoo, Dong Gon; Shin, Dong Rock

    2015-01-01

    To investigate different computed tomography (CT) features among adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and lepidic predominant invasive adenocarcinoma (LPA) that appeared as ground-glass nodules (GGN). We also analyzed different CT findings between Group A (AIS and MIA) and Group B (LPA). We evaluated 19 AIS, 4 MIA, and 9 LPA images that were histologically confirmed and manifested as GGN on thin-section CT scans. CT scans were assessed for lesion characteristics: size, shape, solid portion, internal air density, marginal irregularity and pleural tag. CT findings of Group A and Group B were analyzed using the Kruskal-Wallis test or Fisher's exact test. A significant statistical difference was seen between AIS and LPA for lesion characteristics (p < 0.05). No significant difference was observed between AIS and MIA. Round or polygonal shape with smooth margin was significantly associated with Group A, and complex shape with marginal irregularity was associated with Group B. Group A (AIS and MIA) could be distinguished from Group B (LPA) by smaller lesion size, round or polygonal shape, smaller solid portion and smooth margin

  2. Ground-glass nodule on thin-section CT: Differentiation among adenocarcinoma in situ, minimally invasive adenocarcinoma and lepidic predominant invasive adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Man Ho; Ryu, Dae Shick; Kim, Do Young; Ahn, Jae Hong; Choi, Soo Jung; Gang, Gil Hyeon; Yoo, Dong Gon; Shin, Dong Rock [Gangneung Asan Hospital, College of Medicine, University of Ulsan, Gangneung (Korea, Republic of)

    2015-12-15

    To investigate different computed tomography (CT) features among adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA), and lepidic predominant invasive adenocarcinoma (LPA) that appeared as ground-glass nodules (GGN). We also analyzed different CT findings between Group A (AIS and MIA) and Group B (LPA). We evaluated 19 AIS, 4 MIA, and 9 LPA images that were histologically confirmed and manifested as GGN on thin-section CT scans. CT scans were assessed for lesion characteristics: size, shape, solid portion, internal air density, marginal irregularity and pleural tag. CT findings of Group A and Group B were analyzed using the Kruskal-Wallis test or Fisher's exact test. A significant statistical difference was seen between AIS and LPA for lesion characteristics (p < 0.05). No significant difference was observed between AIS and MIA. Round or polygonal shape with smooth margin was significantly associated with Group A, and complex shape with marginal irregularity was associated with Group B. Group A (AIS and MIA) could be distinguished from Group B (LPA) by smaller lesion size, round or polygonal shape, smaller solid portion and smooth margin.

  3. Hepatopulmonary syndrome induced by common bile duct ligation in a rabbit model: correlation between pulmonary vascular dilatation on thin-section CT and angiography and serum nitrite concentration or endothelial nitric oxide synthase (eNOS)1 expression

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Lee, Jin Wha; Kim, Ki Nam; Park, Byung Ho; Kwak, Jong Young; Jeong, Jin Sook; Kim, Young Hoon

    2004-01-01

    To investigate the correlation between radiologic vascular dilatation and serum nitrite concentration and eNOS expression in the endothelial cell and pneumocyte in a rabbit model of hepatopulmonary syndrome induced by common bile duct ligation (CBDL). Thin-section CT scans of the lung and pulmonary angiography were obtained 3 weeks after CBDL (n=6), or a sham operation (n=4), and intrapulmonary vasodilatation was assessed. The diameter and tortuosity of peripheral vessels in the right lower lobe by thin-section CT and angiography at the same level of the right lower lobe in all subjects were correlated to serum nitrite concentration and eNOS (endothelial nitric oxide synthase) expression as determined by immunostaining. The diameters of pulmonary vessels on thin-section CT were well correlated with nitrite concentrations in serum (r=0.92, ρ < 0.001). Dilated pulmonary vessels were significantly correlated with an increased eNOS expression (r=0.94, ρ < 0.0001), and the severity of pulmonary vessel tortuosity was found to be well correlated with serum nitrite concentration (r=0.90, ρ < 0.001). The peripheral pulmonary vasculature in hepatopulmonary syndrome induced by CBLD was dilated on thin-section CT and on angiographs. Our findings suggest that peripheral pulmonary vascular dilatations are correlated with serum nitrite concentrations and pulmonary eNOS expression

  4. Paper-thinned diaphragm: CT sign of diaphragmatic eventration

    International Nuclear Information System (INIS)

    Im, Jung Gi; Han, Man Chung; Kim, Chu Wan; Shim, Young Soo

    1990-01-01

    CT findings of total left hemidiaphragmatic eventration in two adult patients are described. Chest radiograph showed elevated left hemidiaphragm and left hilum. Paper-thinned muscular portion of the diseased diaphragm was clearly demonstrated with CT scan. With demonstration of paper-thinned diaphragm by CT scan, differentiation of the diaphragmatic eventration from recent onset phrenic nerve paralysis by tumor invasion or from post-traumatic diaphragmatic hernia can be made

  5. Paper-thinned diaphragm: CT sign of diaphragmatic eventration

    Energy Technology Data Exchange (ETDEWEB)

    Im, Jung Gi; Han, Man Chung; Kim, Chu Wan; Shim, Young Soo [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1990-10-15

    CT findings of total left hemidiaphragmatic eventration in two adult patients are described. Chest radiograph showed elevated left hemidiaphragm and left hilum. Paper-thinned muscular portion of the diseased diaphragm was clearly demonstrated with CT scan. With demonstration of paper-thinned diaphragm by CT scan, differentiation of the diaphragmatic eventration from recent onset phrenic nerve paralysis by tumor invasion or from post-traumatic diaphragmatic hernia can be made.

  6. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi [Shiga Univ. of Medical Science, Otsu (Japan)

    1998-10-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  7. Benign pulmonary nodule. Morphological features and contrast enhancement evaluated with contiguous thin-section CT

    International Nuclear Information System (INIS)

    Matsuo, Hisayasu; Murata, Kiyoshi; Takahashi, Masashi; Morita, Rikushi

    1998-01-01

    The morphological changes in 54 benign lung nodules, including 8 histologically proven nodules of tuberculoma, 10 of focal organizing pneumonia (FOP), 1 of lung abscess and 35 other benign nodules, were evaluated with contiguous thin-section (3 mm) CT. In addition, incremental dynamic studies were carried out in 25 of these nodules. The three-dimensional shapes of the nodules were found to be quite varied and were classified into four types: round mass (n=18), polygonal mass with concave or straight margins (n=20), oval or band-like mass extending along the bronchovascular bundle (n=7), and oval mass attached to the pleura with broad contact (n=9). Forty-two (78%) of the 54 nodules were located along the bronchovascular bundle. The maximum increments in CT values over 20 HU were observed after contrast enhancement in 18 (72%) of the 25 benign nodules, among which all tuberculomas showed little or no contrast enhancement. The number of small vessels quantified microscopically in the center of the nodules were minimal in tuberculomas with little enhancement and plentiful in lesions of FOP and abscess which showed marked enhancement. Our results suggest that the differentiation between benign and malignant pulmonary nodules is not possible simply on the basis of the degree of contrast enhancement. Therefore, morphological features and the anatomical relation to the bronchovascular bundles should also be taken into consideration in the diagnosis of pulmonary nodules. (author)

  8. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    International Nuclear Information System (INIS)

    Yanagawa, Masahiro; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo; Daimon, Tadahisa; Honda, Osamu; Mihara, Naoki; Johkoh, Takeshi; Nakamura, Hironobu

    2009-01-01

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61-0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma

  9. Thin-section CT of lung without ECG gating: 64-detector row CT can markedly reduce cardiac motion artifact which can simulate lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)], E-mail: m-yanagawa@radiol.med.osaka-u.ac.jp; Tomiyama, Noriyuki; Sumikawa, Hiromitsu; Inoue, Atsuo [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Daimon, Tadahisa [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medicine, Division of Pulmonary Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Mihara, Naoki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Radiology, Osaka Advanced Medical Imaging Center, 5-20-1 Momoyamadai, Suita-city, Osaka 565-0854 (Japan); Johkoh, Takeshi [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Department of Medical Physics, Osaka University Graduate School of Medicine, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan); Nakamura, Hironobu [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita-city, Osaka 565-0871 (Japan)

    2009-01-15

    Purpose: Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate. Materials and methods: Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48-126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients. Results: Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, {kappa} = 0.61-0.71), and fair or poor in the other evaluations ({kappa} < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test). Conclusion: The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of

  10. Characteristics of pulmonary cysts in Birt-Hogg-Dube syndrome: Thin-section CT findings of the chest in 12 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tobino, Kazunori, E-mail: tobino@juntendo.ac.jp [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Gunji, Yoko [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Kurihara, Masatoshi [Pneumothorax Center, Nissan Tamagawa Hospital, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); The Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan); Kunogi, Makiko; Koike, Kengo [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871 (Japan); Johkoh, Takeshi [Department of Radiology, Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Kurumazuka 3-1, Itami, Hyogo 664-0872 (Japan); Kodama, Yuzo [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Iwakami, Shin-ichiro [Department of Respiratory Medicine, Juntendo University, Shizuoka Hospital, 1129 Nagaoka, Izunokuni, Shizuoka 410-2295 (Japan); Kikkawa, Mika [Biochemical Research Center, Division of Proteomics and Biomolecular Sciences, Juntendo University, Graduate School of Medicine, Bunkyo-Ku, Tokyo (Japan); Takahashi, Kazuhisa [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Seyama, Kuniaki [Department of Respiratory Medicine, Juntendo University, School of Medicine, 2-1-1 Hongo, Bunkyo-Ku, Tokyo 113-8421 (Japan); Study Group of Pneumothorax and Cystic Lung Diseases, 4-8-1 Seta, Setagaya-Ku, Tokyo 158-0095 (Japan)

    2011-03-15

    Purpose: To describe in detail the characteristic chest computed tomography (CT) findings of Birt-Hogg-Dube (BHD) syndrome. Materials and methods: Thin-section chest CT scans of consecutive 12 patients with genetically diagnosed BHD syndrome were retrospectively evaluated by two observers, especially about the characteristics (distribution, number, size, shape and relation to pleura) of pulmonary cysts. Interobserver agreement in the identification of abnormalities on the CT images was achieved using the {kappa} statistic, and the degree of interobserver correlation for the characterization of pulmonary cysts was assessed using the Spearman rank correlation coefficient. Results: Multiple pulmonary cysts were seen in all patients. The number of cysts in each patient was various (range, 29-407), and cysts of various sizes (from a few mm to 2 cm or more) were seen in all patient. 76.6% (mean) of cysts were irregular-shaped, and 40.5% (mean) of cysts were located along the pleura. The mean extent score of cysts was 13% of the whole lung, and the distribution of cysts was predominantly in the lower medial zone. Finally, cysts abutting or including the proximal portions of lower pulmonary arteries or veins were also seen in all patients. Conclusion: Multiple, irregular-shaped cysts of various sizes with lower medial lung zone predominance are characteristic CT findings of BHD syndrome. Cysts abutting or including the proximal portions of lower pulmonary arteries or veins may also exist in this syndrome in a high probability.

  11. Characteristics of pulmonary cysts in Birt-Hogg-Dube syndrome: Thin-section CT findings of the chest in 12 patients

    International Nuclear Information System (INIS)

    Tobino, Kazunori; Gunji, Yoko; Kurihara, Masatoshi; Kunogi, Makiko; Koike, Kengo; Tomiyama, Noriyuki; Johkoh, Takeshi; Kodama, Yuzo; Iwakami, Shin-ichiro; Kikkawa, Mika; Takahashi, Kazuhisa; Seyama, Kuniaki

    2011-01-01

    Purpose: To describe in detail the characteristic chest computed tomography (CT) findings of Birt-Hogg-Dube (BHD) syndrome. Materials and methods: Thin-section chest CT scans of consecutive 12 patients with genetically diagnosed BHD syndrome were retrospectively evaluated by two observers, especially about the characteristics (distribution, number, size, shape and relation to pleura) of pulmonary cysts. Interobserver agreement in the identification of abnormalities on the CT images was achieved using the κ statistic, and the degree of interobserver correlation for the characterization of pulmonary cysts was assessed using the Spearman rank correlation coefficient. Results: Multiple pulmonary cysts were seen in all patients. The number of cysts in each patient was various (range, 29-407), and cysts of various sizes (from a few mm to 2 cm or more) were seen in all patient. 76.6% (mean) of cysts were irregular-shaped, and 40.5% (mean) of cysts were located along the pleura. The mean extent score of cysts was 13% of the whole lung, and the distribution of cysts was predominantly in the lower medial zone. Finally, cysts abutting or including the proximal portions of lower pulmonary arteries or veins were also seen in all patients. Conclusion: Multiple, irregular-shaped cysts of various sizes with lower medial lung zone predominance are characteristic CT findings of BHD syndrome. Cysts abutting or including the proximal portions of lower pulmonary arteries or veins may also exist in this syndrome in a high probability.

  12. Additional effects of FDG-PET to thin-section CT for the differential diagnosis of lung nodules. A Japanese multicenter clinical study

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Murakami, Koji; Inoue, Tomio; Saga, Tsuneo; Shiomi, Susumu

    2011-01-01

    This study was a controlled multicenter clinical study on patients with peripheral lung nodules to verify the improvement in the diagnostic ability of fluorodeoxyglucose-positron emission tomography (FDG-PET) when used in combination with thin-section CT (TS-CT). Patients with peripheral lung nodules (long maximal diameter: 10-30 mm) detected using CT were examined using TS-CT and FDG-PET for the differential diagnosis of benign or malignant lesions. The primary endpoint was the specificity of the results using a combination of TS-CT and FDG-PET, compared with the results for TS-CT alone. Images were interpreted by investigators at each institution. Blind readings were also performed by an independent image interpretation committee. The gold standard was a pathological diagnosis determined using a surgical or biopsy specimen obtained after PET; and the patients in whom a pathological diagnosis could not be obtained were diagnosed based on a follow-up TS-CT performed more than 6 months later. Adverse reactions to FDG were also evaluated. The blind reading results for 82 lesions in 81 subjects eligible for analysis among the 90 subjects included in the study showed a specificity of 91.2% (31/34) (95% confidence interval (CI): 76.3-98.1) for TS-CT + PET, compared with a specificity of 67.6% (23/34) (95% CI: 49.5-82.6) for TS-CT alone. The specificity was significantly improved by the addition of the PET findings (p<0.05). The sensitivity improved from 89.6% (43/48) for TS-CT to 91.7% (44/48) for TS-CT + PET; the addition of PET increased the level of confidence in the diagnosis, but the difference was not significant. The results reported by the institutional investigators were not significantly different. No serious adverse reactions occurred, although two of the 90 subjects exhibited mild adverse reactions. The addition of FDG-PET to TS-CT for the differential diagnosis of benign or malignant peripheral lung nodules resulted in a significant improvement in

  13. Localized-low attenuation of the lung on thin-section CT in experimentally induced pulmonary arterial occlusion with balloon catheter in pigs

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Goo, Jin Mo; Im, Jung Gi; Kim, Ji Hye

    2008-01-01

    To determine whether a localized low-attenuation (LLA) is induced on a thin-section CT (TSCT) during an acute pulmonary arterial occlusion in pigs. In eight pigs, 14 sites of the descending pulmonary artery were obstructed using balloon catheters. The lung TSCTs were obtained immediately after pulmonary artery obstruction (n=13), 10 min (n=10), 30 min (n=14) and 60 min (n=14) after pulmonary artery obstruction at the end of expiration. The TSCTs were also obtained after balloon-deflation at the end of expiration (n=11) and with the balloon-reinflation at inspiration (n=6). Of the 14 sites of pulmonary artery obstruction, 11 (79%) showed LLA. However, LLA progressively became fainter or disappeared on a follow-up CT in seven sites. When the balloon was deflated, 10 of the 11 sites measured showed no change in lung attenuation. After full inspiration, LLA disappeared in three of the six sites. The corresponding areas of LLA on the CT showed a statistically significant increase compared to the baseline CT immediately after inflation (ρ =0.021) and 30 minutes after inflation (ρ = 0.041), and after balloon deflation (ρ = 0.036). LLA was induced by acute pulmonary artery obstruction. However, LLA, gradually faded over the 60 minutes following obstruction. LLAs were maintained despite the restoration of pulmonary arterial flow, but disappeared as a result of a full inspiration. Thus, LLA might be caused by air trapping

  14. Three-section expiratory CT

    DEFF Research Database (Denmark)

    Loeve, Martine; de Bruijne, Marleen; Hartmann, Ieneke C. J.

    2012-01-01

    . Longitudinal follow-up was performed with three sections. All images were deidentified and randomized, and TA was scored with the Brody II system and a new quantitative system. Statistical analysis included the Wilcoxon signed rank test, calculation of Spearman and intraclass correlation coefficients, and use......Purpose: To estimate the effect of the number of computed tomography (CT) sections on trapped air (TA) assessment in patients with cystic fibrosis (CF) by using an established scoring system and a new quantitative scoring system and to compare CT and pulmonary function test (PFT) estimates of TA...

  15. Thin-section CT of the skull base

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Gamroth, A.; Tiedemann, K.

    1987-01-01

    High-resolution CT-images of the skull base are depicted and anatomical structures are described. A large variety of osseous and soft tissue structures can be differentiated in the temporal bone, nasopharynx and orbita. Knowledge of the anatomical structures is essential for the recognition of pathological changes and also plays an essential role for the diagnostically involved radiologist. (orig.) [de

  16. Comparison of 133Xe gas dynamic SPECT and thin-section CT in patients with pulmonary emphysema

    International Nuclear Information System (INIS)

    Takahashi, Kazue; Satoh, Katashi; Ohkawa, Motoomi

    2001-01-01

    We assessed 133 Xe gas dynamic single photon emission computed tomography (SPECT) by comparing washout axial images with thin-section CT (TSCT) in patients with pulmonary emphysema. Twenty-three patients were studied. All patients were diagnosed as having pulmonary emphysema on the basis of TSCT. We compared TSCT of upper, middle and lower lung fields with 133 Xe gas dynamic SPECT axial images at the corresponding levels during the 3 to 4 minutes of washout phase. If the degree of 133 Xe gas retention or TSCT finding of ventral and dorsal parts was not the same, the images were divided into two parts. A total of 174 lesions in 23 cases were examined, but 3 lesions having no retention of 133 Xe gas at equilibrium phase were excluded. The results showed that: there were 37 lesions (21.6%) with equivalent severity on both images; there were 42 lesions (24.5%) with more severity on 133 Xe gas dynamic SPECT than on TSCT; and there were 92 lesions (53.8%) with more severity on TSCT than on 133 Xe gas dynamic SPECT. The severity on 133 Xe gas dynamic SPECT and TSCT was not always compatible. One of the reasons for the variable 133 Xe gas retention even when the lesion had the same severity on TSCT, may be bronchial stricture which cannot be seen on TSCT. By comparison of axial images of 133 Xe gas dynamic SPECT with CT images, we could recognize the areas of 133 Xe gas retention in detail. Results suggest that 133 Xe gas dynamic SPECT can be useful to identify ventilation impairment in pulmonary emphysema. (author)

  17. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  18. Sliding thin slab, minimum intensity projection imaging for objective analysis of emphysema

    International Nuclear Information System (INIS)

    Satoh, Shiro; Ohdama, Shinichi; Shibuya, Hitoshi

    2006-01-01

    The aim of this study was to determine whether sliding thin slab, minimum intensity projection (STS-MinIP) imaging is more advantageous than thin-section computed tomography (CT) for detecting and assessing emphysema. Objective quantification of emphysema by STS-MinIP and thin-section CT was defined as the percentage of area lower than the threshold in the lung section at the level of the aortic arch, tracheal carina, and 5 cm below the carina. Quantitative analysis in 100 subjects was performed and compared with pulmonary function test results. The ratio of the low attenuation area in the lung measured by STS-MinIP was significantly higher than that found by thin-section CT (P<0.01). The difference between STS-MinIP and thin-section CT was statistically evident even for mild emphysema and increased depending on whether the low attenuation in the lung increased. Moreover, STS-MinIP showed a stronger regression relation with pulmonary function results than did thin-section CT (P<0.01). STS-MinIP can be recommended as a new morphometric method for detecting and assessing the severity of emphysema. (author)

  19. The value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice

    International Nuclear Information System (INIS)

    Huang Zhi; Liu Zhang; Yang Chaoxiang; Lin Chengye; Zhang Li; Li Yuxiang; Ma Yunyan; Xiao Haisong; Lu Zhifeng; Wang Bo; Zhou Yunhong

    2009-01-01

    Objective: To approach the value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice in order to improve the correctness of the diagnosis. Methods: Analysis the cases' clinical manifestation and the CT images, who were diagnosed as obstructive jaundice by operation. All of cases had high-resolution computed tomograyhy scan. The thickness and the interval is 5mm, reconstructed the thickness and the interval to 1 mm and 1.5 mm, then send the images to the workstation and MRR were processed. Analysis the date with the pathology. Results: Spiral CT thin imaging reconstruction have 98% and 93% in the accuracy of location and characterization in the obstruction. Conclusion: The spiral CT thin imaging reconstruction is a good method to improve the accuracy of location and characterization in the obstructive jaundice. (authors)

  20. Coronary CT angiography characteristics of OCT-defined thin-cap fibroatheroma. A section-to-section comparison study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dong Hyun; Koo, Hyun Jung; Kang, Joon-Won; Lim, Tae-Hwan [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Kang, Soo-Jin; Chang, Mineok; Lee, Pil Hyung; Roh, Jae-Hyung; Ahn, Jung-Min; Park, Duk-Woo; Lee, Seung-Whan; Lee, Cheol Whan; Park, Seong-Wook; Park, Seung-Jung; Kim, Young-Hak [Asan Medical Center, University of Ulsan College of Medicine, Department of Cardiology, Seoul (Korea, Republic of); Baek, Seunghee [Asan Medical Center, University of Ulsan College of Medicine, Department of Clinical Epidemiology and Biostatistics, Seoul (Korea, Republic of); Han, Seungbong [Gachon University, Department of Applied Statistics, Gyeonggi-do (Korea, Republic of); Mintz, Gary S. [Cardiovascular Research Foundation, New York, NY (United States)

    2018-02-15

    To evaluate whether plaque characteristics as assessed by coronary computed tomography angiography (CCTA) were associated with the presence of a thin-cap fibroatheroma (TCFA) - a precursor of plaque rupture - defined by optical coherence tomography (OCT) in a section-to-section-level comparison. From 28 symptomatic patients, 31 coronary lesions were evaluated on 727 cross-sections co-registered by both CCTA and OCT. CCTA plaque characteristics included low attenuation plaque (LAP, <30 HU), napkin ring sign (NRS), positive remodelling (PR, remodelling index ≥1.10), and spotty calcification and plaque area and plaque burden. By OCT, presence of TCFA, lumen area and arc of lipid were determined. OCT revealed a TCFA in 69 (9.4%) sections from 19 (61.2 %) lesions. In per-section analysis, OCT-TCFA showed higher frequency of CCTA-detected LAP (58.0% vs. 18.5%), NRS (31.9% vs. 8.8%) and PR (68.1% vs. 48.0%) and greater plaque burden (70.6% vs. 61.9%) as compared to sections without OCT-TCFA (all p < 0.05). In multivariable analysis, LAP (odds ratio [OR] 4.05, p < 0.001) and NRS (OR 2.47, p = 0.005) were associated with OCT-TCFA. CCTA-measured lumen area correlated well with OCT-measured lumen area (R = 0.859, limits of agreement -0.5 ± 3.7 mm{sup 2}). LAP and NRS in CCTA were associated with the presence of OCT-defined TCFA in a section-to-section comparison. (orig.)

  1. 1975 Memorial Award Paper. Image generation and display techniques for CT scan data. Thin transverse and reconstructed coronal and sagittal planes.

    Science.gov (United States)

    Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J

    1975-01-01

    The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.

  2. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Tominaga, Lichto; Maehata, Yoshiyasu; Sawada, Eiichi; Araki, Tsutomu; Onishi, Hiroshi; Aoki, Shinichi; Koshiishi, Tsuyota; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Araya, Masayuki; Saito, Ryo

    2011-01-01

    Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present

  3. Thin-slice high-resolution CT study of pulmonary asbestosis and idiopathic interstitial pneumonia

    International Nuclear Information System (INIS)

    Hatakeyama, Masayuki; Maeda, Munehiro; Ohmura, Takuya

    1987-01-01

    Thin-slice high-resolution CT findings were compared between 36 patients with pulmonary asbestos exposure (AS) and 33 patients with idiopathic interstitial pneumonia (IIP). The CT scans of these patients were classified into 5 types (0-IV) by the subpleural curvilinear shadow (SCLS) and honey-comb shadow (HS). SCLS was detected in 22 (62 %) patients with AS and 7 (21 %) with IIP. HS was detected in 14 (39 %) patients with AS and 33 (100 %) with IIP. In both the diseases, SCLS was distributed mainly in the lower lobe in CT types I and II, and in mildly fibrotic segments in types III and IV. In CT types II, III and IV, SCLS was always communicated with HS. Thin-slice high-resolution CT is considered very helpful in diagnosis and staging of not only AS and IIP but also pulmonary fibrosis. (author)

  4. High-resolution CT of the lungs: Anatomic-pathologic correlation

    International Nuclear Information System (INIS)

    Stein, M.G.; Webb, W.R.; Finkbeiner, W.; Gamsu, G.

    1986-01-01

    The interpretation of thin-section (1.5-mm), high-resolution CT scans of the lungs has been limited by lack of direct radiologic and pathologic correlation. The author scanned fresh inflated isolated lungs from ten healthy and five diseased subjects using thin-section, high-resolution techniques. The lungs were then fixed by inflation with endobronchial Formalin. Gough sections (1 mm thick) were obtained at the same levels as the CT scans. In healthy subjects, secondary lobules were identified by the presence of visible interlobular septa and central arterioles. In some patients with disease, septal thickening was visible. In patients with honeycombing cystic areas of destroyed lung were seen, along with areas of fibrosis. Emphysema was well evaluated. Thin-section, high-resolution CT can define lung architecture and may resolve mild changes of the interstitium

  5. CT of the pelvis after cesarean section

    International Nuclear Information System (INIS)

    Twickler, D.; Setiawan, H.; Harrell, R.; Brown, C.E.L.

    1989-01-01

    Febrile morbidity following cesarean section is often evaluated with CT, although the CT appearance of the normal uterus has not been evaluated. This study was undertaken to learn the normal uterine appearance after cesarean section. To date, 15 women who also underwent bilateral tubal ligation have been studied. Six had a vertical uterine incision; nine had a low transverse incision. Contrast-enhanced pelvic CT was performed 1--5 days after surgery. All women were asymptomatic, with a normal postpartum course

  6. A microfluidic approach to water-rock interactions using thin rock sections: Pb and U sorption onto thin shale and granite sections

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Youn Soo [Institute of Mine Reclamation Technology, Mine Reclamation Corp., 2 Segye-ro, Wonju-si, Gangwon-do, 26464 (Korea, Republic of); Jo, Ho Young, E-mail: hyjo@korea.ac.kr [Department of Earth and Environmental Sciences, Korea University, Anam-dong, Seongbuk-gu, Seoul, 02841 (Korea, Republic of); Ryu, Ji-Hun; Kim, Geon-Young [Korea Atomic Energy Research Institute, 1045 Daedeokdaero, Yuseong-gu, Daejeon, 34057 (Korea, Republic of)

    2017-02-15

    Highlights: • Microfluidic tests was used to investigate water-rock (mineral) interactions. • Pb and U sorption onto thin shale and granite sections was evaluated. • Pb removal by thin shale section is related primarily to Fe-containing minerals. • A slightly larger amount of U was removed onto the thin granite section with Fe-containing minerals. - Abstract: The feasibility of using microfluidic tests to investigate water-rock (mineral) interactions in fractures regarding sorption onto thin rock sections (i.e., shale and granite) of lead (Pb) and uranium (U) was evaluated using a synthetic PbCl{sub 2} solution and uranium-containing natural groundwater as fluids. Effluent composition and element distribution on the thin rock sections before and after microfluidic testing were analyzed. Most Pb removal (9.8 mg/cm{sup 2}) occurred within 3.5 h (140 PVF), which was 74% of the total Pb removal (13.2 mg/cm{sup 2}) at the end of testing (14.5 h, 560 PVF). Element composition on the thin shale sections determined by μ-XRF analysis indicated that Pb removal was related primarily to Fe-containing minerals (e.g., pyrite). Two thin granite sections (biotite rich, Bt-R and biotite poor, Bt-P) exhibited no marked difference in uranium removal capacity, but a slightly higher amount of uranium was removed onto the thin Bt-R section (266 μg/cm{sup 2}) than the thin Bt-P section (240 μg/cm{sup 2}) within 120 h (4800 PVF). However, uranium could not be detected by micro X-ray fluorescence (μ-XRF) analysis, likely due to the detection limit. These results suggest that microfluidic testing on thin rock sections enables quantitative evaluation of rock (mineral)-water interactions at the micro-fracture or pore scale.

  7. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Directory of Open Access Journals (Sweden)

    Saito Ryo

    2011-10-01

    Full Text Available Abstract Background Chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT, appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%. Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months. Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%, of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present.

  8. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Science.gov (United States)

    2011-01-01

    Background Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present. PMID:21995807

  9. Restoration of Thickness, Density, and Volume for Highly Blurred Thin Cortical Bones in Clinical CT Images.

    Science.gov (United States)

    Pakdel, Amirreza; Hardisty, Michael; Fialkov, Jeffrey; Whyne, Cari

    2016-11-01

    In clinical CT images containing thin osseous structures, accurate definition of the geometry and density is limited by the scanner's resolution and radiation dose. This study presents and validates a practical methodology for restoring information about thin bone structure by volumetric deblurring of images. The methodology involves 2 steps: a phantom-free, post-reconstruction estimation of the 3D point spread function (PSF) from CT data sets, followed by iterative deconvolution using the PSF estimate. Performance of 5 iterative deconvolution algorithms, blind, Richardson-Lucy (standard, plus Total Variation versions), modified residual norm steepest descent (MRNSD), and Conjugate Gradient Least-Squares were evaluated using CT scans of synthetic cortical bone phantoms. The MRNSD algorithm resulted in the highest relative deblurring performance as assessed by a cortical bone thickness error (0.18 mm) and intensity error (150 HU), and was subsequently applied on a CT image of a cadaveric skull. Performance was compared against micro-CT images of the excised thin cortical bone samples from the skull (average thickness 1.08 ± 0.77 mm). Error in quantitative measurements made from the deblurred images was reduced 82% (p < 0.01) for cortical thickness and 55% (p < 0.01) for bone mineral mass. These results demonstrate a significant restoration of geometrical and radiological density information derived for thin osseous features.

  10. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  11. Differences in the definition of internal target volumes using slow CT alone or in combination with thin-slice CT under breath-holding conditions during the planning of stereotactic radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Seki, Satoshi; Kunieda, Etsuo; Takeda, Atsuya; Nagaoka, Tomoaki; Deloar, Hossain M.; Kawase, Takatsugu; Fukada, Junichi; Kawaguchi, Osamu; Uematsu, Minoru; Kubo, Atsushi

    2007-01-01

    Purpose: To investigate how the delineations of the internal target volume (ITV) made from 'slow' CT alter with reference to 'thin-slice' CT. Materials and methods: Thin-slice CT images taken under breath-holding conditions and slow CT images taken under shallow-breathing conditions (8 s/image) of 11 lung cancers were used for this study. Five radiation oncologists delineated ITV of the 11 lesions using slow CT images (ITV1), and then redefined them with reference to thin-slice CT images (ITV2). SD-images (standard deviation image) were created for all patients from ITV images in order to visualize the regional variation of the ITVs. Results: The mean value of ITV2 was smaller than that initially defined by ITV1. There was no significant change in ITV1 and ITV2 between operators with regard to standard deviation in volume. There was a significant difference in the distribution of the ratio of ITV1 to ITV2 obtained on thin-slice CTs between cases with and without ground glass opacity. In cases without ground glass opacity there was a tendency for ITV2 to have a smaller volume than ITV1. Conclusions: Combined use of slow CT and thin-slice CT in delineation of ITV contours appeared to be useful in making adjustments for obscured tumor images caused by respiratory movement

  12. Prevalence of 'high-riding' superior pericardial recesses on thin-section 16-MDCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Basile, Antonio [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy)]. E-mail: antodoc@yahoo.com; Bisceglie, Paola [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Giulietti, Giorgio [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Calcara, Giacomo [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Figuera, Michele [Department of Radiology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Mundo, Elena [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Granata, Antonio [Department of Nephrology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Runza, Giuseppe [Department of Radiology, Policlinico Universitario, Via del Vespro 129, 90127 Palermo (Italy); Privitera, Carmelo [Department of Radiology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Privitera, Giambattista [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Patti, Maria Teresa [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy)

    2006-08-15

    Objective: The aim of this study was to evaluate the prevalence of 'high-riding' superior pericardial recess (HRSPR) on thin-section (1 mm) 16-multidetector computed tomography (MDCT) scans. Materials and methods: Three hundred and fourteen consecutive chest CT scans obtained with a thin-section 16 MDCT were retrospectively evaluated. The prevalence and characteristic of HRSPR were analyzed. Results: HRSPR was depicted in 21 patients (11 men and 10 women) (6.6%) who ranged in age from 28 to 72 years (mean age, 57 years). The extended recesses were rounded/oval shaped in five patients and triangular, spindle, half moon or irregular shaped in the other 16 patients. Conclusion: Our data suggest as HRSPRs are more frequently and better depicted on thinsection MDCT scans, and this improves the capability to distinguish this superior extension of the superior aortic recess from abnormal findings such as lymphadenopathy, cystic lesions, and aortic dissection.

  13. Content Model Use and Development to Redeem Thin Section Records

    Science.gov (United States)

    Hills, D. J.

    2014-12-01

    The National Geothermal Data System (NGDS) is a catalog of documents and datasets that provide information about geothermal resources located primarily within the United States. The goal of NGDS is to make large quantities of geothermal-relevant geoscience data available to the public by creating a national, sustainable, distributed, and interoperable network of data providers. The Geological Survey of Alabama (GSA) has been a data provider in the initial phase of NGDS. One method by which NGDS facilitates interoperability is through the use of content models. Content models provide a schema (structure) for submitted data. Schemas dictate where and how data should be entered. Content models use templates that simplify data formatting to expedite use by data providers. These methodologies implemented by NGDS can extend beyond geothermal data to all geoscience data. The GSA, using the NGDS physical samples content model, has tested and refined a content model for thin sections and thin section photos. Countless thin sections have been taken from oil and gas well cores housed at the GSA, and many of those thin sections have related photomicrographs. Record keeping for these thin sections has been scattered at best, and it is critical to capture their metadata while the content creators are still available. A next step will be to register the GSA's thin sections with SESAR (System for Earth Sample Registration) and assign an IGSN (International Geo Sample Number) to each thin section. Additionally, the thin section records will be linked to the GSA's online record database. When complete, the GSA's thin sections will be more readily discoverable and have greater interoperability. Moving forward, the GSA is implementing use of NGDS-like content models and registration with SESAR and IGSN to improve collection maintenance and management of additional physical samples.

  14. Thin-section computed tomography findings in 104 immunocompetent patients with adenovirus pneumonia.

    Science.gov (United States)

    Park, Chan Kue; Kwon, Hoon; Park, Ji Young

    2017-08-01

    Background To date, there has been no computed tomography (CT) evaluation of adenovirus pneumonia in a large number of immunocompetent patients. Purpose To describe the thin-section CT findings of immunocompetent patients with adenovirus pneumonia. Material and Methods We prospectively enrolled 104 patients with adenovirus pneumonia from a military hospital. CT scans of each patient were retrospectively and independently assessed by two radiologists for the presence of abnormalities, laterality and zonal predominance of the parenchymal abnormalities, and dominant imaging patterns and their anatomic distributions. Results CT findings included consolidation (n = 92), ground-glass opacity (GGO; n = 82), septal thickening (n = 34), nodules (n = 46), bronchial wall thickening (n = 32), pleural effusion (n = 16), and lymphadenopathy (n = 3). Eighty-four patients (81%) exhibited unilateral parenchymal abnormalities and 57 (57%) exhibited lower lung zone abnormalities. The most frequently dominant CT pattern was consolidation with surrounding GGO (n = 50), with subpleural (70%) and peribronchovascular (94%) distributions. Consolidation-the second-most common pattern (n = 33)-also exhibited subpleural (79%) and peribronchovascular (97%) distributions. The dominant nodule pattern (n = 14) exhibited mixed (64%) and peribronchovascular (100%) distributions. A dominant GGO pattern was only observed in four patients; none had central distribution. Conclusion Although the manifestations of adenovirus pneumonia on CT are varied, we found the most frequent pattern was consolidation with or without surrounding GGO, with subpleural and peribronchovascular distributions. Parenchymal abnormalities were predominantly unilateral and located in the lower lung zone. If dominant consolidation findings are present in immunocompetent patients during the early stages, adenovirus pneumonia should be considered.

  15. Comparison of capability of dynamic O2-enhanced MRI and quantitative thin-section MDCT to assess COPD in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Yoshikawa, Takeshi; Matsumoto, Keiko; Aoyama, Nobukazu; Onishi, Yumiko; Takenaka, Daisuke; Matsumoto, Sumiaki; Nishimura, Yoshihiro; Sugimura, Kazuro

    2012-01-01

    Purpose: The purpose of this study was to directly and prospectively compare the capability of dynamic O 2 -enhanced MRI and quantitatively assessed thin-section MDCT to assess smokers’ COPD in a large prospective cohort. Materials and methods: The GOLD criteria for smokers were used to classify 187 smokers into four clinical stage groups as follows: smokers without COPD (n = 56) and with mild (n = 54), moderate (n = 52) and severe or very severe COPD (n = 24). All smokers underwent dynamic O 2 -enhanced MRI, MDCT and pulmonary function tests. Mean relative enhancement ratio and mean wash-in time on MRI and CT-based functional lung volume (CT-based FLV) as well as the ratio of airway wall area to total airway area on MDCT were computationally calculated. Then, all indexes were significantly correlated with functional parameters. To determine the efficacy of all indexes for clinical stage classification, the indexes for the four clinical groups were statistically compared by using Tukey's honestly significant difference multiple comparison test. Results: All indexes had significant correlations with functional parameters (p 2 -enhanced MRI for assessment of COPD in smokers is potentially as efficacious as quantitatively assessed thin-section MDCT.

  16. Pulmonary sarcoidosis: morphologic associations of airflow obstruction at thin section CT

    International Nuclear Information System (INIS)

    Hansel DM; Milne DS; Lwilher M; Wells AU

    1999-01-01

    The present study tries to determine the consequences and the correlation between the lung function and the scannographic patron to guide toward the understanding of the possible mechanisms responsible for the obstruction of the air roads in the sarcoidosis. A prospective study was carried out during two years in 45 patients, 27 of masculine sex, the discoveries of the CT were classified in five states, according to the commitment parenchymatose with or without commitment ganglionar, to the calculation of the committed lung volume and the description of radiological patterns as attenuation diminished in mosaic pattern, burnished glass, nodules, obscurely with or without air bronchogramma and reticular pattern. To all the patients they were carried out tests of lung function in the same month of the taking of the CT

  17. Application of artificial neural networks in the CT study of solitary pulmonary nodule

    International Nuclear Information System (INIS)

    Wang Xiaohua; Ma Daqing; Chen Hui; Gao Peiyi; Zhou Xinhua

    2006-01-01

    Objective: To establish a new-type discriminative method in differentiating benign from malignant solitary pulmonary nodule (SPN) on high-resolution CT/thin-section CT by using artificial neural networks theory in the CT diagnostic study of SPN. Methods: Two hundred SPNs pathologically proved by operation or biopsy (primary pulmonary carcinoma 135 eases, benign nodules 65 cases) were collected, 3 clinical characteristics (age, sex, with or without bloody sputum) and 9 high-resolution CT/thin-section CT characteristics (location, long and short diameter, contour, spiculation, halo sign, air-space, relation with the adjacent blood vessels and pleura) were analyzed. 140 cases were randomly selected to form the training samples, on which artificial neural networks model (BP networks) was built and compared with Logistic model from Statistical Package for the Social Science (SPSS) software. Results: The total consistent rate of BP neural networks (98.0%, 196/200) was higher than that of Logistic model (86.0%, 172/200) (P<0.001). Areas under ROC curve were 0.996±0.004 and 0.936±0.017, respectively, and the difference between the two was significant (P<0.001). Conclusion: Using high-resolution CT and thin-section CT in combination with artificial neural networks theory is feasible, and it is expected to become a useful and reliable clinical tool in differentiating benign from malignant SPN. (authors)

  18. Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: Experimental study using chest phantom

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Kono, Atsushi A.; Kusaka, Akiko; Konishi, Minoru; Yoshii, Masaru; Sugimura, Kazuro

    2010-01-01

    Purpose: The purpose of this study was to assess the influence of reconstruction algorithm on identification and image quality of ground-glass opacities (GGOs) and partly solid nodules on low-dose thin-section CT. Materials and methods: A chest CT phantom including simulated GGOs and partly solid nodules was scanned with five different tube currents and reconstructed by using standard (A) and newly developed (B) high-resolution reconstruction algorithms, followed by visually assessment of identification and image quality of GGOs and partly solid nodules by two chest radiologists. Inter-observer agreement, ROC analysis and ANOVA were performed to compare identification and image quality of each data set with those of the standard reference. The standard reference used 120 mA s in conjunction with reconstruction algorithm A. Results: Kappa values (κ) of overall identification and image qualities were substantial or almost perfect (0.60 < κ). Assessment of identification showed that area under the curve of 25 mA reconstructed with reconstruction algorithm A was significantly lower than that of standard reference (p < 0.05), while assessment of image quality indicated that 50 mA s reconstructed with reconstruction algorithm A and 25 mA s reconstructed with both reconstruction algorithms were significantly lower than standard reference (p < 0.05). Conclusion: Reconstruction algorithm may be an important factor for identification and image quality of ground-glass opacities and partly solid nodules on low-dose CT examination.

  19. Prevalence of ligamentum arteriosum calcification on multi-section spiral CT and digital radiography.

    Science.gov (United States)

    Hong, Gil-Sun; Goo, Hyun Woo; Song, Jae-Woo

    2012-06-01

    To investigate the prevalence of ligamentum arteriosum calcification (LAC) on multi-section spiral CT and digital radiography. Five hundred and eight children and 232 adults who performed multi-section chest CT were included in this study and were divided into nine age groups: A (0-5 years), B (6-10 years), C (11-15 years), D (16-20 years), E (21-30 years), F (31-40 years), G (41-50 years), H (51-60 years), and I (61-70 years). Two radiologists assessed the presence of LAC on axial and coronal CT images, defined as focal calcific density on both or on one plane with attenuation >100 Hounsfield unit. The prevalence of LAC on CT was compared between children and adults, and between unenhanced and enhanced CT in children. The prevalence of LAC on digital radiography was evaluated in 476 children. The prevalence of definite LAC on unenhanced multi-section CT was significantly higher in children (37.8 %) than in adults (11.2 %) (P CT were 4.5, 12.8, 8.1, 19.0, 0.0, 0.0, 0.0, 2.0, and 1.9 %. In children, the prevalence of LAC was significantly higher on unenhanced than on enhanced CT (37.8 vs. 16.4 %, P children. LAC is frequently observed in children and adults on multi-section spiral CT, more frequently than previously reported. Compared with that on multi-section spiral CT, the prevalence of LAC on digital radiography is substantially low.

  20. Drug-sensitive tuberculosis, multidrug-resistant tuberculosis, and nontuberculous mycobacterial pulmonary disease in nonAIDS adults: comparisons of thin-section CT findings

    International Nuclear Information System (INIS)

    Chung, Myung Jin; Lee, Kyung Soo; Kim, Tae Sung; Kim, Sung Mok; Koh, Won-Jung; Kwon, O Jung; Kang, Eun Young; Kim, Seonwoo

    2006-01-01

    The aim of this work was to compare thin-section CT (TSCT) findings of drug-sensitive (DS) tuberculosis (TB), multidrug-resistant (MDR) TB, and nontuberculous mycobacterial (NTM) pulmonary disease in nonAIDS adults. During 2003, 216 (113 DS TB, 35 MDR TB, and 68 NTM) patients with smear-positive sputum for acid-fast bacilli (AFB), and who were subsequently confirmed to have mycobacterial pulmonary disease, underwent thoracic TSCT. The frequency of lung lesion patterns on TSCT and patients' demographic data were compared. The commonest TSCT findings were tree-in-bud opacities and nodules. On a per-person basis, significant differences were found in the frequency of multiple cavities and bronchiectasis (P<0.001, chi-square test and multiple logistic regression analysis). Multiple cavities were more frequent in MDR TB than in the other two groups and extensive bronchiectasis in NTM disease (multiple logistic regression analysis). Patients with MDR TB were younger than those with DS TB or NTM disease (P<0.001, multiple logistic regression analysis). Previous tuberculosis treatment history was significantly more frequent in patients with MDR TB or NTM disease (P<0.001, chi-square test and multiple logistic regression analysis). In patients with positive sputum AFB, multiple cavities, young age, and previous tuberculosis treatment history imply MDR TB, whereas extensive bronchiectasis, old age, and previous tuberculosis treatment history NTM disease. (orig.)

  1. Drug-sensitive tuberculosis, multidrug-resistant tuberculosis, and nontuberculous mycobacterial pulmonary disease in nonAIDS adults: comparisons of thin-section CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Jin; Lee, Kyung Soo; Kim, Tae Sung; Kim, Sung Mok [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea); Koh, Won-Jung; Kwon, O Jung [Sungkyunkwan University School of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Seoul (Korea); Kang, Eun Young [Korea University Guro Hospital, Department of Diagnostic Radiology, Korea University College of Medicine, Seoul (Korea); Kim, Seonwoo [Sungkyunkwan University School of Medicine, Biostatistics Unit of the Samsung Biomedical Research Institute, Samsung Medical Center, Seoul (Korea)

    2006-09-15

    The aim of this work was to compare thin-section CT (TSCT) findings of drug-sensitive (DS) tuberculosis (TB), multidrug-resistant (MDR) TB, and nontuberculous mycobacterial (NTM) pulmonary disease in nonAIDS adults. During 2003, 216 (113 DS TB, 35 MDR TB, and 68 NTM) patients with smear-positive sputum for acid-fast bacilli (AFB), and who were subsequently confirmed to have mycobacterial pulmonary disease, underwent thoracic TSCT. The frequency of lung lesion patterns on TSCT and patients' demographic data were compared. The commonest TSCT findings were tree-in-bud opacities and nodules. On a per-person basis, significant differences were found in the frequency of multiple cavities and bronchiectasis (P<0.001, chi-square test and multiple logistic regression analysis). Multiple cavities were more frequent in MDR TB than in the other two groups and extensive bronchiectasis in NTM disease (multiple logistic regression analysis). Patients with MDR TB were younger than those with DS TB or NTM disease (P<0.001, multiple logistic regression analysis). Previous tuberculosis treatment history was significantly more frequent in patients with MDR TB or NTM disease (P<0.001, chi-square test and multiple logistic regression analysis). In patients with positive sputum AFB, multiple cavities, young age, and previous tuberculosis treatment history imply MDR TB, whereas extensive bronchiectasis, old age, and previous tuberculosis treatment history NTM disease. (orig.)

  2. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  3. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  4. Application of 2 mm thin-slice scanning with bone algorithm on conventional CT in diagnosis of the pulmonary diseases

    International Nuclear Information System (INIS)

    Zhang Xianheng; Li Xiuhua; Wang Fenghua

    2004-01-01

    Objective: To evaluate the value of 2 mm thin-slice conventional CT scan with bone algorithm in diagnosis and differential diagnosis in the pulmonary diseases. Methods: In total 135 cases of the pulmonary diseases were routinely scanned by conventional scan, 10 mm per slice, with standard algorithm, then the 2 mm thin-slice scan with bone algorithm was performed at the interested region of the lungs. Result: According to the comparative study of the CT signs between 10 mm slice scan with standard algorithm and 2 mm thin-slice scan with bone algorithm, the latter was better on displaying the pulmonary axial interstium, intralobular septum, subpleura lines, honeycombing, 2-5 mm nodulars and anomalies of bronchial wall. Conclusion: According to the study of 135 cases, 2 mm thin-slice scan with bone algorithm is superior to 10 mm slice scan with standard algorithm in demonstrating the pulmonary lesions. It has a similar value with high-resolution spiral CT in the diagnosis of the pulmonary solitary or diffuse nodules, pulmonary diffuse interstitial lesions and the lesions of the airway. It is practical and advisable in the community hospital

  5. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.

    2001-01-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  6. Obscure gastrointestinal bleeding: preliminary comparison of 64-section CT enteroclysis with video capsule endoscopy

    International Nuclear Information System (INIS)

    Khalife, Samer; Vahedi, Kouroche; Dray, Xavier; Marteau, Philippe; Soyer, Philippe; Hamzi, Lounis; Place, Vinciane; Boudiaf, Mourad; Alatawi, Abdullah

    2011-01-01

    To retrospectively compare the diagnostic capabilities of 64-section CT enteroclysis with those of video capsule endoscopy (VCE) to elucidate the cause of obscure gastrointestinal bleeding. Thirty-two patients who had 64-section CT enteroclysis and VCE because of obscure gastrointestinal bleeding were included. Imaging findings were compared with those obtained at double balloon endoscopy, surgery and histopathological analysis, which were used as a standard of reference. Concordant findings were found in 22 patients (22/32; 69%), including normal findings (n = 13), tumours (n = 7), lymphangiectasia (n = 1) and inflammation (n = 1), and discrepancies in 10 patients (10/32; 31%), including ulcers (n = 3), angioectasias (n = 2), tumours (n = 2) and normal findings (n = 3). No statistical difference in the proportions of abnormal findings between 64-section CT enteroclysis (11/32; 34%) and VCE (17/32, 53%) (P = 0.207) was found. However, 64-section CT enteroclysis helped identify tumours not detected at VCE (n = 2) and definitely excluded suspected tumours (n = 3) because of bulges at VCE. Conversely, VCE showed ulcers (n = 3) and angioectasias (n = 2) which were not visible at 64-section CT enteroclysis. Our results suggest that 64-section CT enteroclysis and VCE have similar overall diagnostic yields in patients with obscure gastrointestinal bleeding. However, the two techniques are complementary in this specific population. (orig.)

  7. The in vivo relationship between cross-sectional area and CT dose index in abdominal multidetector CT with automatic exposure control

    Energy Technology Data Exchange (ETDEWEB)

    Meeson, S; Alvey, C M; Golding, S J, E-mail: stuart.meeson@nds.ox.ac.u [Radiology Group, Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU (United Kingdom)

    2010-06-15

    The relationship between patient cross-sectional area and both volume CT dose index (CTDI) and dose length product was explored for abdominal CT in vivo, using a 16 multidetector row CT (MDCT) scanner with automatic exposure control. During a year-long retrospective survey of patients with MDCT for symptoms of abdominal sepsis, cross-sectional areas were estimated using customised ellipses at the level of the middle of vertebra L3. The relationship between cross-sectional area and the exposure parameters was explored. Scans were performed using a LightSpeed 16 (GE Healthcare Medical Systems, Milwaukee, WI) operated with tube current modulation. From a survey of 94 patients it was found that the CTDI increased with the increase in patient cross-sectional area. The relationship was logarithmic rather than linear, with a least-squares fit to the data (R{sup 2} = 0.80). For abdominal CT the cross-sectional area gave a measure of patient size based on the region of the body to be exposed. Exposure parameters increased with increasing cross-sectional area and the greater radiation exposure of larger patients was partly a consequence of their size. Given increasing obesity levels we believe that cross-sectional area and scan length should be added to future dose surveys, allowing patient size to be considered as a factor of relevance when examining population doses.

  8. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  9. Thin-Section Diffusion-Weighted Magnetic Resonance Imaging of the Brain with Parallel Imaging

    International Nuclear Information System (INIS)

    Oner, A.Y.; Celik, H.; Tali, T.; Akpek, S.; Tokgoz, N.

    2007-01-01

    Background: Thin-section diffusion-weighted imaging (DWI) is known to improve lesion detectability, with long imaging time as a drawback. Parallel imaging (PI) is a technique that takes advantage of spatial sensitivity information inherent in an array of multiple-receiver surface coils to partially replace time-consuming spatial encoding and reduce imaging time. Purpose: To prospectively evaluate a 3-mm-thin-section DWI technique combined with PI by means of qualitative and quantitative measurements. Material and Methods: 30 patients underwent conventional echo-planar (EPI) DWI (5-mm section thickness, 1-mm intersection gap) without parallel imaging, and thin-section EPI-DWI with PI (3-mm section thickness, 0-mm intersection gap) for a b value of 1000 s/mm 2 , with an imaging time of 40 and 80 s, respectively. Signal-to-noise ratio (SNR), relative signal intensity (rSI), and apparent diffusion coefficient (ADC) values were measured over a lesion-free cerebral region on both series by two radiologists. A quality score was assigned for each set of images to assess the image quality. When a brain lesion was present, contrast-to-noise ratio (CNR) and corresponding ADC were also measured. Student t-tests were used for statistical analysis. Results: Mean SNR values of the normal brain were 33.61±4.35 and 32.98±7.19 for conventional and thin-slice DWI (P>0.05), respectively. Relative signal intensities were significantly higher on thin-section DWI (P 0.05). Quality scores and overall lesion CNR were found to be higher in thin-section DWI with parallel imaging. Conclusion: A thin-section technique combined with PI improves rSI, CNR, and image quality without compromising SNR and ADC measurements in an acceptable imaging time. Keywords: Brain; DWI; parallel imaging; thin section

  10. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Dept. of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Dept. of Radiology, Danderyds Hospital (Sweden)

    2001-03-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  11. Emergency department CT screening of patients with nontraumatic neurological symptoms referred to the posterior fossa: comparison of thin versus thick slice images.

    Science.gov (United States)

    Kamalian, Shervin; Atkinson, Wendy L; Florin, Lauren A; Pomerantz, Stuart R; Lev, Michael H; Romero, Javier M

    2014-06-01

    Evaluation of the posterior fossa (PF) on 5-mm-thick helical CT images (current default) has improved diagnostic accuracy compared to 5-mm sequential CT images; however, 5-mm-thick images may not be ideal for PF pathology due to volume averaging of rapid changes in anatomy in the Z-direction. Therefore, we sought to determine if routine review of 1.25-mm-thin helical CT images has superior accuracy in screening for nontraumatic PF pathology. MRI proof of diagnosis was obtained within 6 h of helical CT acquisition for 90 consecutive ED patients with, and 88 without, posterior fossa lesions. Helical CT images were post-processed at 1.25 and 5-mm-axial slice thickness. Two neuroradiologists blinded to the clinical/MRI findings reviewed both image sets. Interobserver agreement and accuracy were rated using Kappa statistics and ROC analysis, respectively. Of the 90/178 (51 %) who were MR positive, 60/90 (66 %) had stroke and 30/90 (33 %) had other etiologies. There was excellent interobserver agreement (κ > 0.97) for both thick and thin slice assessments. The accuracy, sensitivity, and specificity for 1.25-mm images were 65, 44, and 84 %, respectively, and for 5-mm images were 67, 45, and 85 %, respectively. The diagnostic accuracy was not significantly different (p > 0.5). In this cohort of patients with nontraumatic neurological symptoms referred to the posterior fossa, 1.25-mm-thin slice CT reformatted images do not have superior accuracy compared to 5-mm-thick images. This information has implications on optimizing resource utilizations and efficiency in a busy emergency room. Review of 1.25-mm-thin images may help diagnostic accuracy only when review of 5-mm-thick images as current default is inconclusive.

  12. Production technique for thin undecalcified bone sections suitable for autoradiography

    International Nuclear Information System (INIS)

    Farnham, J.E.; Schlenker, R.A.

    1985-01-01

    The production of thin bone sections using power-driven grinding equipment is described. With such equipment, sections can be readily ground to thicknesses between 30 and 40 μm in a rapid and controlled fashion. The yield of usable sections is nearly 100%

  13. Thin-section computed tomography–histopathologic comparisons of pulmonary focal interstitial fibrosis, atypical adenomatous hyperplasia, adenocarcinoma in situ, and minimally invasive adenocarcinoma with pure ground-glass opacity

    Energy Technology Data Exchange (ETDEWEB)

    Si, Ming-Jue, E-mail: smjsh@hotmail.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Tao, Xiao-Feng, E-mail: taoxiaofeng1963@hotmail.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Du, Guang-Ye, E-mail: 715376158@qq.com [Department of Pathology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Cai, Ling-Ling, E-mail: caill_00@163.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Han, Hong-Xiu, E-mail: hanhongxiu@hotmail.com [Department of Pathology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Liang, Xi-Zi, E-mail: liangxizish@hotmail.com [Department of Pathology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China); Zhao, Jiang-Min, E-mail: zhaojiangmin1962@hotmail.com [Department of Radiology, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, No. 280, Mohe Road, Shanghai 201999 (China)

    2016-10-15

    Objective: To retrospectively compare focal interstitial fibrosis (FIF), atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), and minimally invasive adenocarcinoma (MIA) with pure ground-glass opacity (GGO) using thin-section computed tomography (CT). Materials and methods: Sixty pathologically confirmed cases were reviewed including 7 cases of FIF, 17 of AAH, 23of AIS, and 13 of MIA. All nodules kept pure ground glass appearances before surgical resection and their last time of thin-section CT imaging data before operation were collected. Differences of patient demographics and CT features were compared among these four types of lesions. Results: FIF occurred more frequently in males and smokers while the others occurred more frequently in female nonsmokers. Nodule size was significant larger in MIA (P < 0.001, cut-off value = 7.5 mm). Nodule shape (P = 0.045), margin characteristics (P < 0.001), the presence of pleural indentation (P = 0.032), and vascular ingress (P < 0.001) were significant factors that differentiated the 4 groups. A concave margin was only demonstrated in a high proportion of FIF at 85.7% (P = 0.002). There were no significant differences (all P > 0.05) in age, malignant history, attenuation value, location, and presence of bubble-like lucency. Conclusion: A nodule size >7.5 mm increases the possibility of MIA. A concave margin could be useful for differentiation of FIF from the other malignant or pre-malignant GGO nodules. The presence of spiculation or pleural indentation may preclude the diagnosis of AAH.

  14. Diagnostic performance of 64-section CT using CT gastrography in preoperative T staging of gastric cancer according to 7th edition of AJCC cancer staging manual

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Lim, Hyo Soon; Jeong, Yong Yeon; Kang, Heoung Keun; Choi, Yoo Duk; Park, Young Kyu; Park, Chang Hwan

    2012-01-01

    To evaluate the accuracy of 64-section multidetector CT with CT gastrography for determining the depth of mural invasion in patients with gastric cancer according to the 7th edition of the AJCC cancer staging manual. A total of 127 patients with gastric cancer and who had undergone both esophago-gastro-duodenoscopy and 64-section CT were included in this study. Two radiologists independently reviewed the preoperative CT images with respect to the detectability and T-staging of the gastric cancers. The sensitivity, specificity, accuracy and overall accuracy of each reviewer for the T staging of gastric cancer were calculated. Overall, gastric cancer was detected in 123 (96.9%) of the 127 cancers on the CT images. Reviewer 1 correctly staged 98 gastric cancers, and reviewer 2 correctly classified 105 gastric cancers. The overall diagnostic accuracy of the T staging was 77.2% (98/127) for reviewer 1 and 82.7% (105/127) for reviewer 2. 64-section CT using CT gastrography showed a reasonable diagnostic performance for determining the T staging in patients with gastric cancer according to the 7th edition of the AJCC cancer staging manual. (orig.)

  15. Tomography high Resolution CT findings of nontuberculous mycobacterial pulmonary disease: Comparison between the first treatment and the re treatment group

    Energy Technology Data Exchange (ETDEWEB)

    Gwak, Soon Hyuk; Cho, Bum Sang; Jeon, Min Hee; Kim, Eun Young; Kang, Min Ho; Yi, Kyung Sik; Lee, Seung Young; Kim, Sung Jin; Lee, Ki Man [Chungbuk National Univ., Cheongju, (Korea, Republic of)

    2012-06-15

    To analyze and compare the thin section CT findings of first and re treatment nontuberculous mycobacterial (NTM) pulmonary disease. Between January 2005 and April 2010, 121 patients with positive sputum culture for NTM were recruited. We included only 32 patients underwent high resolution chest CT and were confirmed by American Thoracic Society criteria NTM pulmonary infection (first treatment 15, re treatment 17 patients). CT images of 32 patients were reviewed retrospectively. We evaluated the frequency and laterality of the followings; nodule, increased density, bronchial change, parenchymal change. The significantly frequent CT findings of the re treatment NTM group were well defined nodules (retreatment 82.4%, first treatment 33.3%, p = 0.00), consolidations (retreatment 88.2%, first treatment 53.3%, p = 0.03), bronchial changes (bronchiectasis; retreatment 100%, first treatment 66.6%, p = 0.01, bronchial narrowing; retreatment 23.5%, first treatment 0%, p = 0.04 and mucoid impaction; retreatment-58.8%, first treatment-20.0%, p = 0.03) and atelectasis with bronchiectasis (retreatment-88.2%, first treatment 26.7%, p = 0.00). However, most of the evaluated thin section CT findings, such as centrilobular and ill defined nodules, lobular, segmental and subpleural consolidations, ground glass attenuation, bronchial wall thickening, cavities, pleural lesions, fibrotic band, emphysema and laterality of lesions, have not shown significant differences between first treatment and the re treatment group. Thin section CT findings of well defined nodules, consolidations, bronchial changes (bronchiectasis, bronchial narrowing and mucoid impaction) and atelectasis with bronchiectasis are highly suggestive of re treatment NTM pulmonary disease.

  16. Magnetic, in situ, mineral characterization of Chelyabinsk meteorite thin section

    Science.gov (United States)

    Nabelek, Ladislav; Mazanec, Martin; Kdyr, Simon; Kletetschka, Gunther

    2015-06-01

    Magnetic images of Chelyabinsk meteorite's (fragment F1 removed from Chebarkul lake) thin section have been unraveled by a magnetic scanning system from Youngwood Science and Engineering (YSE) capable of resolving magnetic anomalies down to 10-3 mT range from about 0.3 mm distance between the probe and meteorite surface (resolution about 0.15 mm). Anomalies were produced repeatedly, each time after application of magnetic field pulse of varying amplitude and constant, normal or reversed, direction. This process resulted in both magnetizing and demagnetizing of the meteorite thin section, while keeping the magnetization vector in the plane of the thin section. Analysis of the magnetic data allows determination of coercivity of remanence (Bcr) for the magnetic sources in situ. Value of Bcr is critical for calculating magnetic forces applicable during missions to asteroids where gravity is compromised. Bcr was estimated by two methods. First method measured varying dipole magnetic field strength produced by each anomaly in the direction of magnetic pulses. Second method measured deflections of the dipole direction from the direction of magnetic pulses. Bcr of magnetic sources in Chelyabinsk meteorite ranges between 4 and 7 mT. These magnetic sources enter their saturation states when applying 40 mT external magnetic field pulse.

  17. Tracheomalacia in adults with cystic fibrosis: determination of prevalence and severity with dynamic cine CT.

    LENUS (Irish Health Repository)

    McDermott, Shaunagh

    2012-02-01

    PURPOSE: To determine the prevalence and severity of tracheomalacia in adults with cystic fibrosis (CF) by using dynamic cine multidetector computed tomography (CT) and to correlate these findings with pulmonary function test (PFT) results and the severity of parenchymal lung disease. MATERIALS AND METHODS: In this institutional review board-approved HIPAA-compliant study, 40 patients with CF (22 men, 18 women; mean age, 28 years +\\/- 8 [standard deviation]; age range, 18-54 years) prospectively underwent PFTs, standard thin-section CT, and two dynamic cine multidetector CT acquisitions. Ten control subjects underwent dynamic cine multidetector CT. After standard thin-section CT was completed, dynamic cine multidetector CT was performed during a forced expiratory maneuver and during coughing. Dynamic cine multidetector CT images in nine patients were excluded. Maximal inspiratory, dynamic expiratory, and end-expiratory tracheal luminal areas were compared (Student t test) and correlated (Spearman rank) with PFT results and severity of parenchymal lung disease. RESULTS: Mean predicted forced expiratory volume in 1 second (FEV(1)) was 70.6% +\\/- 20.7, and mean Bhalla CT score was 41.8% +\\/- 13.6. In patients with CF, dynamic cine mean tracheal cross-sectional area reduction was 51.7% +\\/- 18.4 (range, 9%-89%) for forced expiratory maneuvers and 68.8% +\\/- 11.7 (range, 18%-88%) for coughing (P = .001). Tracheomalacia was demonstrated in 24 (69%) patients and no control subjects during forced expiratory maneuvers (P = .001) and in 10 (29%) patients and one (10%) control subject during coughing. For end-expiration images, mean tracheal luminal reduction was 16.1% +\\/- 14.0% (range, 0.0%-53.0%), with one patient demonstrating tracheal luminal reduction of more than 50%. There was no correlation between tracheal cross-sectional luminal reduction and either predicted FEV(1) or CT Bhalla score. CONCLUSION: Tracheomalacia depicted at dynamic cine multidetector CT is a

  18. Spiral hydro-CT of the pancreas in the thin-slice method

    International Nuclear Information System (INIS)

    Richter, G.M.; Simon, C.; Hoffmann, V.; DeBernardinis, M.; Seelos, R.; Senninger, N.; Kauffmann, G.W.

    1996-01-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [de

  19. Effectiveness of thin-slice axial images of multidetector row CT for visualization of bronchial artery before bronchial arterial embolization

    International Nuclear Information System (INIS)

    Shida, Yoshitaka; Hasuo, Kanehiro; Aibe, Hitoshi; Kubo, Yuko; Terashima, Kotaro; Kinjo, Maya; Kamano, H.; Yoshida, Atsuko

    2008-01-01

    We assessed the ability of visualization of bronchial artery (BA) by using thin-slice axial images of 4-detector multidetector row CT in 65 patients with hemoptysis. In all patients, the origins of BA were well identified with observation of consecutive axial images with 1 mm thickness by paging method and bronchial arterial embolization (BAE) was performed successfully. Thin-slice axial images were considered to be useful to recognize BA and to perform BAE in patients with hemoptysis. (author)

  20. Degenerative osteoarthritis of atlanto-odontoid joint: CT findings and clinical analysis

    International Nuclear Information System (INIS)

    Xu Aide; Wang Song; Mao Yunhua

    1998-01-01

    Purpose: To analyze the CT appearances and clinical aspects of the degeneration at atlanto-odontoid(A-O) joint. Methods: Thin section axial CT scans, of AO joints were studied in 317 consecutive patients who underwent brain or cervical spine CT examinations. The images were viewed using double-blind method. Observation included: osteophytosis, changes of joint space and transverse ligament, and the clinical symptoms as well. Results: CT findings of AO joint degeneration included: formation of osteophyte, narrowing of joint space, transverse ligament calcification, and joint vacuum phenomenon. Among individuals above 40 years of age, the incidence of degeneration at AO joint went up gradually (P<0.01). Conclusion: Degeneration of AO joint was not uncommon among aged people, CT could better demonstrate the pathological changes

  1. Arterial blood supply to the thalamus and midbrain on CT sections, 2

    International Nuclear Information System (INIS)

    Takeshita, Gen; Ottomo, Michinori; Satoh, Nobuko; Yokoyama, Yoshiaki.

    1984-01-01

    The selective injection of a dyestuff into thalamoperforating arteries from the posterior part of the circle of Willis, using five postmortem brains, was performed. After fixation, sections parallel to the orbito-meatal line were obtained. In cases which showed a standard development of the posterior communicating arteries, the usual patterns were as follows: the area supplied by perforators of the posterior communicating artery (anterior thalamoperforating artery) was visualized in the hypothalamus and the antero-lateral part of the thalamus; the area supplied by perforators of the proximal segment of the posterior cerebral artery (interpeduncular thalamoperforating artery) was visualized in the midbrain and the medial part of thalamus; the area supplied by perforators of the ambient segment of the posterior cerebral artery (thalamogeniculate artery) was visualized in the medial part of the geniculate body and the posterior part of the thalamus. According to the development of the posterior communicating artery, the area supplied by each perforator was quite variable. Three CT sections were obtained containing three different patterns of the posterior communicating artery: 1) well-developed; 2) moderately developed; and 3) poorly developed. The identification of the area supplied by thalamoperforating arteries on CT sections was quite useful in the CT diagnosis of cerebrovascular disorders which involved the thalamus and the midbrain. (author)

  2. Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines

    International Nuclear Information System (INIS)

    Coselmon, Martha M.; Balter, James M.; McShan, Daniel L.; Kessler, Marc L.

    2004-01-01

    The advent of dynamic radiotherapy modeling and treatment techniques requires an infrastructure to weigh the merits of various interventions (breath holding, gating, tracking). The creation of treatment planning models that account for motion and deformation can allow the relative worth of such techniques to be evaluated. In order to develop a treatment planning model of a moving and deforming organ such as the lung, registration tools that account for deformation are required. We tested the accuracy of a mutual information based image registration tool using thin-plate splines driven by the selection of control points and iterative alignment according to a simplex algorithm. Eleven patients each had sequential CT scans at breath-held normal inhale and exhale states. The exhale right lung was segmented from CT and served as the reference model. For each patient, thirty control points were used to align the inhale CT right lung to the exhale CT right lung. Alignment accuracy (the standard deviation of the difference in the actual and predicted inhale position) was determined from locations of vascular and bronchial bifurcations, and found to be 1.7, 3.1, and 3.6 mm about the RL, AP, and IS directions. The alignment accuracy was significantly different from the amount of measured movement during breathing only in the AP and IS directions. The accuracy of alignment including thin-plate splines was more accurate than using affine transformations and the same iteration and scoring methodology. This technique shows promise for the future development of dynamic models of the lung for use in four-dimensional (4-D) treatment planning

  3. Peripheral laser iridoplasty opens angle in plateau iris by thinning the cross-sectional tissues

    Directory of Open Access Journals (Sweden)

    Liu J

    2013-09-01

    Full Text Available Ji Liu,1,2 Tania Lamba,1 David A Belyea1 1Department of Ophthalmology, The George Washington University, Washington DC, USA; 2Yale Eye Center, Yale University, New Haven, CT, USA Abstract: Plateau iris syndrome has been described as persistent angle narrowing or occlusion with intraocular pressure elevation after peripheral iridotomy due to the abnormal plateau iris configuration. Argon laser peripheral iridoplasty (ALPI is an effective adjunct procedure to treat plateau iris syndrome. Classic theory suggests that the laser causes the contraction of the far peripheral iris stroma, "pulls" the iris away from the angle, and relieves the iris-angle apposition. We report a case of plateau iris syndrome that was successfully treated with ALPI. Spectral domain optical coherence tomography confirmed the angle was open at areas with laser treatment but remained appositionally closed at untreated areas. Further analysis suggested significant cross-sectional thinning of the iris at laser-treated areas in comparison with untreated areas. The findings indicate that APLI opens the angle, not only by contracting the iris stroma, but also by thinning the iris tissue at the crowded angle. This is consistent with the ALPI technique to aim at the iris as far peripheral as possible. This case also suggests that spectral domain optical coherence tomography is a useful adjunct imaging tool to gonioscopy in assessing the angle condition. Keywords: plateau iris, optic coherence tomography, argon laser peripheral iridoplasty, angle-closure glaucoma

  4. Cross-sectional imaging with CT and/or MRI of pediatric chest tumors

    International Nuclear Information System (INIS)

    Wyttenbach, R.; Vock, P.; Tschaeppeler, H.

    1998-01-01

    The purpose of this study was to provide an overview of the spectrum of pediatric chest masses, to present the results of cross-sectional imaging with CT and/or MRI, and to define diagnostic criteria to limit differential diagnosis. Seventy-eight children with thoracic mass lesions were retrospectively evaluated using CT (72 patients) and/or MR imaging (12 patients). All masses were evaluated for tissue characteristics (attenuation values or signal intensity, enhancement, and calcification) and were differentiated according to age, gender, location, and etiology. Twenty-eight of 38 (74 %) mediastinal masses were malignant (neuroblastoma, malignant lymphoma). Thirty of 38 (79 %) pulmonary masses were metastatic in origin, all with an already known primary tumor (osteosarcoma, Wilms tumor). With one exception, all remaining pulmonary lesions were benign. Seventeen of 21 (81 %) chest wall lesions were malignant (Ewing sarcoma, primitive neuroectodermal tumor). The majority of mediastinal and chest wall tumors in children is malignant. Lung lesions are usually benign, unless a known extrapulmonary tumor suggests pulmonary metastases. Cross-sectional imaging with CT and/or MRI allows narrowing of the differential diagnosis of pediatric chest masses substantially by defining the origin and tissue characteristics. Magnetic resonance imaging is preferred for posterior mediastinal lesions, whereas CT should be used for pulmonary lesions. For the residual locations both modalities are complementary. (orig.)

  5. The value of sub-stages and thin slices for the assessment of the medial clavicular epiphysis: a prospective multi-center CT study.

    Science.gov (United States)

    Wittschieber, Daniel; Schulz, Ronald; Vieth, Volker; Küppers, Martin; Bajanowski, Thomas; Ramsthaler, Frank; Püschel, Klaus; Pfeiffer, Heidi; Schmidt, Sven; Schmeling, Andreas

    2014-06-01

    The clavicle plays an important role for forensic age estimation in living individuals, particularly with regard to the age of majority. The present prospective study aims to evaluate the age-dependent ossification process of the medial clavicular epiphysis in order to establish the clavicular sub-stages introduced in 2010 as well as the advantages and possibilities of thin-slice computed tomography (CT). For this purpose, 0.6 mm thin-slice CT scans of sternoclavicular joints of 572 bodies aged between 10 and 40 years were evaluated by means of two complementary classification systems: a five-stage system and a sub-staging system for the main stages 2 and 3. Assessment was possible in 493 cases. The results for stages 4 and 5 are in line with previous studies that found the ages of 21 years and 26 years, respectively, as minimum ages for these stages. Sub-stage 3c was first found at the age of 19 years in both sexes, thereby corroborating the value of this sub-stage as to statements about the age of majority. In comparison to other CT studies, stage 3a was first observed ~1 year earlier (16.4 years in males and 15.5 years in females). Stage 2c only occurred in 3 cases. In conclusion, the data corroborate the significance of diagnosing sub-stages as well as the value of thin-slice CT. For forensic practice, the concomitant and complementary use of both classification systems applied in this study can be recommended.

  6. The role of CT in oncology irigography

    International Nuclear Information System (INIS)

    Hako, R.; Gulova, I.

    2013-01-01

    Colorectal cancer is a common malignancy that results in significant morbidity and mortality. CT irigography is an evolving noninvasive imaging technique that relies on performing thin-section CT of the colon evaluating data using both 2D and 3D images. A clean and well-distended colon facilitates detection of colorectal abnormalities whether 2D and 3D techniques are used for data interpretation. Is valuable in planning surgery for colon cancer because it can demonstrate regional extension of tumor as well as adenopathy and distant metastases. Also complications of primary colonic malignancies such as obstructions, perforations, and fistulas can be readily visualized with CT irigography. The liver is the predominant organ to be involved with metastases from colorectal cancer. Other common sites of metastases from colon cancer include the lungs, adrenal glands, and bones. CT is applicable for identifying recurrences, evaluating anatomic relationships, documenting normal postoperative anatomy, and confirming the absence of new lesions during and after therapy. (author)

  7. Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT

    International Nuclear Information System (INIS)

    Soo, G.; Lau, K.K.; Yik, T.; Kutschera, P.

    2010-01-01

    Aim: To evaluate the impact of different reconstructed section thicknesses on liver lesion detection using multidetector computed tomography (CT). Methods: Fifty-three patients were examined using a 16-section CT machine with axial reconstructions provided at 2.5, 5, 7.5, and 10 mm section thicknesses. Images of different reconstructed section thicknesses from different patients were presented in random order to three independent, blinded radiologists for review at multiple sessions. All images were then reviewed by three radiologists in a common session. Consensus was reached following review of the previous interpretation results and results of follow-up imaging regarding the number of true liver lesions (n = 101) for comparison. Results: Mean detection rates were as follows: 93/101 lesions detected with the 2.5 mm section thickness, 98/101 lesions detected at the 5 mm section thickness, 78/101 lesions detected at the 7.5 mm section thickness, and 54/101 lesions detected at the 10 mm section thickness. Lesions missed at the 2.5 mm section thickness were due to masking by image noise. There was particular difficulty detecting subcapsular lesions and lesions adjacent to fissures or the gall bladder at the 7.5 mm and 10 mm section thicknesses. Conclusion: The optimal reconstructed section thickness for lesion detection in the liver was 5 mm.

  8. Incomplete pulmonary fissures evaluated by volumetric thin-section CT: Semi-quantitative evaluation for small fissure gaps identification, description of prevalence and severity of fissural defects

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Radiology Department, German Cancer Research Center (Deutsches Krebsforschungszentrum – DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Radiology, University Hospital of the School of Medicine of Ribeirao Preto – University of Sao Paulo, Av. Bandeirantes 3900, Campus Universitario Monte Alegre, 14048900 Ribeirao Preto, SP (Brazil); Paula, Wagner Diniz de, E-mail: wdpaula@unb.br [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Department of Radiology, University Hospital of the University of Brasilia, Brasilia, DF (Brazil); Owsijewitsch, Michael, E-mail: michael.owsijewitsch@med.uniheidelberg.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Radiology Department, German Cancer Research Center (Deutsches Krebsforschungszentrum – DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Wielpütz, Mark Oliver, E-mail: mark.wielpuetz@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Radiology Department, German Cancer Research Center (Deutsches Krebsforschungszentrum – DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Gompelmann, Daniela, E-mail: daniela.gompelmann@thoraxklinik-heidelberg.de [Pneumology and Respiratory Medicine, Chest Clinic (Thoraxklinik) at University of Heidelberg, Amalienstr. 5, 69126 Heidelberg (Germany); Schlemmer, Heinz-Peter, E-mail: h.schlemmer@dkfz-heidelberg.de [Radiology Department, German Cancer Research Center (Deutsches Krebsforschungszentrum – DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); and others

    2013-12-01

    Objective: To assess the interobserver agreement for a semi-quantitative evaluation of the interlobar fissures integrity in volumetric thin-section CT images, looking for more detailed information regarding fissural defects; and describe prevalence and severity of fissural defects between the different functional groups of subjects. Materials and methods: Volumetric scans of 247 individuals exposed to tobacco with different functional status (normal to severe COPD), were retrospectively and independently evaluated by 2 chest radiologists, with a consensual reading additionally with a third reader in disagreement cases. Right oblique (RO), right horizontal (RH) and left oblique fissures (LO) integrity was estimated using a 5% scale. GOLD classification was available for all subjects. Results: Interobserver agreement (weighted Kappa-index) for fissural categorization was 0.76, 0.70 and 0.75, for RO, RH and LO, respectively. Final evaluation found 81%, 89% and 50% of RO, RH and LO to be incomplete, with respective mean integrity of 80%, 58% and 80%. Small fissure gaps (<10%) were present in 30% of patients. Prevalence and severity of fissural defects were not different between the GOLD categories. Conclusions: A substantial agreement between readers was found in the analysis of interlobar fissures integrity. The semi-quantitative method allowed a detailed description of the fissural defects, information that can be important, for example, in endoscopic lung volume reduction therapies for emphysema. Small fissure gaps, overlooked in previous studies, were found in almost a third of the patients. A higher than previously described prevalence of fissural defects was described, but without significant differences among the distinct functional groups.

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... actual CT scanning is performed. Depending on the type of CT scan, the machine may make several ...

  10. Evaluation of Tracheal and Main Bronchial Diverticula Using Thin-Section MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Jou, Sung Shick; Kim, Young Tong; Bae, Won Kyung; Kim, Il Yung; Kim, Hyung Hwan; Han, Jong Kyu [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2010-02-15

    To evaluate the characteristics of tracheal and main bronchial diverticula in relation with emphysema. A total of 967 CT images were reconstructed with 1.25 mm axial images over 2 months. The incidence, size, number, and location of the tracheal and main bronchial diverticula were analyzed using 3D medical software (Seoul, Korea). The incidence of emphysema and the relationship between emphysema and the size of the diverticula were analyzed. In total, 50 patients (5.1%) showed tracheal diverticula in the right posterolateral wall. In addition, 51 patients (5.2%) showed 89 (9.4%) main bronchial diverticula in the inferior wall, while 68 (72%) showed diverticula in the left posterolateral wall. Tracheal diverticula (6.4 {+-} 5.0 mm, 1.0 {+-} 0.2) were larger and fewer than the main bronchial diverticula (2.1 {+-} 2.0 mm, 1.8 {+-} 1.6) (p<0.05). Moreover, tracheal diverticula (10.3 {+-} 7.4 mm) with emphysema in 13 patients (26%), were larger than those without emphysema (5.1 {+-} 3.0 mm) (p<0.05). On thin-section MDCT, the rates of incidence for tracheal and main bronchial diverticula are about 5%, respectively. Tracheal diverticula in the right posterolateral wall are smaller and fewer than the main bronchial diverticula, which are located primarily in the inferior wall of the left bronchus. Tracheal diverticula with emphysema are larger than those without emphysema.

  11. 4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines.

    Science.gov (United States)

    Min, Yugang; Neylon, John; Shah, Amish; Meeks, Sanford; Lee, Percy; Kupelian, Patrick; Santhanam, Anand P

    2014-09-01

    The accuracy of 4D-CT registration is limited by inconsistent Hounsfield unit (HU) values in the 4D-CT data from one respiratory phase to another and lower image contrast for lung substructures. This paper presents an optical flow and thin-plate spline (TPS)-based 4D-CT registration method to account for these limitations. The use of unified HU values on multiple anatomy levels (e.g., the lung contour, blood vessels, and parenchyma) accounts for registration errors by inconsistent landmark HU value. While 3D multi-resolution optical flow analysis registers each anatomical level, TPS is employed for propagating the results from one anatomical level to another ultimately leading to the 4D-CT registration. 4D-CT registration was validated using target registration error (TRE), inverse consistency error (ICE) metrics, and a statistical image comparison using Gamma criteria of 1 % intensity difference in 2 mm(3) window range. Validation results showed that the proposed method was able to register CT lung datasets with TRE and ICE values <3 mm. In addition, the average number of voxel that failed the Gamma criteria was <3 %, which supports the clinical applicability of the propose registration mechanism. The proposed 4D-CT registration computes the volumetric lung deformations within clinically viable accuracy.

  12. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  13. Two-dimensional MRI at 1.5 and 0.5 T versus CT myelography in the diagnosis of cervical radiculopathy

    International Nuclear Information System (INIS)

    Bartlett, R.J.V.; Rowland Hill, C.A.; Devlin, R.; Gardiner, E.D.

    1996-01-01

    A prospective comparison was made of standard two-dimensional MRI sequences, at both high and midfield strength, with CT myelography in 23 patients with cervical spondylosis. MRI is adequate for assessment of cord compression, where high field strength is superior to midfield strength. MRI using 4-mm sections is inadequate for presurgical assessment of root compression. It remains to be proven whether thin-section white-CSF volume sequences or gadolinium-enhanced volume studies can replace CT myelography. (orig.). With 6 tabs

  14. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  15. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  16. Pulmonary parenchyma segmentation in thin CT image sequences with spectral clustering and geodesic active contour model based on similarity

    Science.gov (United States)

    He, Nana; Zhang, Xiaolong; Zhao, Juanjuan; Zhao, Huilan; Qiang, Yan

    2017-07-01

    While the popular thin layer scanning technology of spiral CT has helped to improve diagnoses of lung diseases, the large volumes of scanning images produced by the technology also dramatically increase the load of physicians in lesion detection. Computer-aided diagnosis techniques like lesions segmentation in thin CT sequences have been developed to address this issue, but it remains a challenge to achieve high segmentation efficiency and accuracy without much involvement of human manual intervention. In this paper, we present our research on automated segmentation of lung parenchyma with an improved geodesic active contour model that is geodesic active contour model based on similarity (GACBS). Combining spectral clustering algorithm based on Nystrom (SCN) with GACBS, this algorithm first extracts key image slices, then uses these slices to generate an initial contour of pulmonary parenchyma of un-segmented slices with an interpolation algorithm, and finally segments lung parenchyma of un-segmented slices. Experimental results show that the segmentation results generated by our method are close to what manual segmentation can produce, with an average volume overlap ratio of 91.48%.

  17. CT colonography: Techniques, indications, findings

    International Nuclear Information System (INIS)

    Mang, Thomas; Graser, Anno; Schima, Wolfgang; Maier, Andrea

    2007-01-01

    Computed tomographic colonography (CTC) is a minimally invasive technique for imaging the entire colon. Based on a helical thin-section CT of the cleansed and air-distended colon, two-dimensional and three-dimensional projections are used for image interpretation. Several clinical improvements in patient preparation, technical advances in CT, and new developments in evaluation software have allowed CTC to develop into a powerful diagnostic tool. It is already well established as a reliable diagnostic tool in symptomatic patients. Many experts currently consider CTC a comparable alternative to conventional colonoscopy, although there is still debate about its sensitivity for the detection of colonic polyps in a screening population. This article summarizes the main indications, the current techniques in patient preparation, data acquisition and data analysis as well as imaging features for common benign and malignant colorectal lesions

  18. Limitations of CT in the prediction of gallstone composition

    International Nuclear Information System (INIS)

    Brink, J.A.; Mueller, P.R.; Simeone, J.F.; Prien, E.L.; Saini, S.; Tung, G.; Ferrucci, J.T.

    1989-01-01

    Gallstones from 87 patients were harvested at cholecystectomy and selected for thin-section specimen CT and crystallographic analysis. A peripheral rim of density different from the center of the stone was noted in 32 (37%) of 87. The relative attenuations (HU) of the stone rim and stone core were recorded as the difference in attenuation from that of the distilled water bath. The correlation of these measurements with the percent cholesterol content in both the rim and core were poor (r = .57, 0.34, respectively). This paper reports the predictive ability of CT examined by defining predominantly cholesterol stones as having a relative core HV ≥ (62 of 87) and core cholesterol content ≥ 80% (59 of 87). Ct correctly predicted the composition as predominantly cholesterol or pigment in 68 of 87 (78%)

  19. Spiral hydro-CT of the pancreas in the thin-slice method; Hydrospiral-CT des Pankreas in Duennschichttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Simon, C. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)]|[Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Hoffmann, V. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); DeBernardinis, M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Seelos, R. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Senninger, N. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-05-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [Deutsch] Von Mai 1994 bis Oktober 1995 wurden

  20. CT features of appendiceal mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Won Jong; Byun, Jae Young; Jung, Jung Im; Lee, Hae Gyu; Park, Young Ha; Shin, Kyung Sub [Catholic University Medical College, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the usefulness of CT features of appendiceal mucocele in the diagnosis and evaluation of complications. We retrospectively reviewed CT findings and compared with operative findings in 7 cases of pathologically proven appendiceal mucocele. CT findings such as location and extent of the lesion, tissue density, thickness or calcification of the wall, presence of adjacent inflammatory infiltration, and visualization of normal vermiform appendix were analyzed. Appendiceal mucocele was found as homogeneous low density cystic mass adjacent to the cecum, which has no surrounding inflammatory infiltration except in one case of perforation and one case of intussusception. Mean CT number measured in 4 cases was 21 Hounsfield unit. Thin curvilinear calcifications were noted along the cystic wall in 2 cases. Normal vermiform appendix couldn't be demonstrated in all cases. Appendiceal mucocele is characterized by homogeneously low density and thin walled cystic tumor adjacent to cecum without surrounding inflammatory infiltration, and absence of normal vermiform appendix on CT. Therefore, CT is valuable in preventing operative complications of appendiceal mucocele.

  1. Oxygen-enhanced MRI vs. quantitatively assessed thin-section CT: Pulmonary functional loss assessment and clinical stage classification of asthmatics

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Koyama, Hisanobu; Matsumoto, Keiko; Onishi, Yumiko; Nogami, Munenobu; Takenaka, Daisuke; Matsumoto, Sumiaki; Sugimura, Kazuro

    2011-01-01

    Purpose: The purpose of this study was to prospectively compare the efficacy of oxygen-enhanced MR imaging (O 2 -enhanced MRI) and CT for pulmonary functional loss assessment and clinical stage classification of asthmatics. Materials and methods: O 2 -enhanced MRI, CT and %FEV 1 measurement were used 34 consecutive asthmatics classified into four stages ('Mild Intermittent [n = 7]', 'Mild Persistent [n = 8], 'Moderate Persistent [n = 14]' and 'Severe Persistent [n = 5]'). Relative enhancement ratio maps for every subject were generated, and determine mean relative enhancement ratios (MRERs). Mean lung density (MLD) and the airway wall area (WA) corrected by body surface area (WA/BSA) were also measured on CT. To compare the efficacy of the two methods for pulmonary functional loss assessment, all indexes were correlated with %FEV 1 . To determine the efficacy of the two methods for clinical stage classification, all parameters for the four clinical stages were statistically compared. Results: %FEV 1 showed fair or moderate correlation with all parameters (0.15 ≤ r 2 ≤ 0.30, p 2 -enhanced MRI is as effective as CT for pulmonary functional loss assessment and clinical stage classification of asthmatics.

  2. The optimal parameter for radiation dose in pediatric low dose abdominal CT: cross-sectional dimensions versus body weight

    International Nuclear Information System (INIS)

    Jung, Yoon Young; Goo, Hyun Woo

    2008-01-01

    To investigate the best parameter between cross-sectional dimensions and body weight in pediatric low dose abdominal CT. One hundred and thirty six children consecutively underwent weight-based abdominal CT. The subjects consisted of group 1 (79 children, weight range 10.0-19.9 kg) and group 2 (57 children, weight range 20.0-39.9 kg). Abdominal cross-sectional dimensions including circumference, area, anteroposterior diameters and transverse diameters were calculated. Image noise (standard deviation of CT density) was measured by placing a region of interest in the posterior segment of the right hepatic lobe on a CT image at the celiac axis. The measured image noise was correlated with the cross-sectional abdominal dimensions and body weight for subjects in each group. In group 1 subjects,area, circumference, transverse diameter, anteroposterior diameter, and body weight showed a significant positive correlation with image noise in descending order(γ = 0.63, 0.62, 0.61, 0.51, and 0.49; ρ < 0.0001). In group 2 subjects, transverse diameter, circumference, area, anteroposterior diameter, and body weight showed a significant positive correlation with image noise in descending order (γ = 0.83, 0.82, 0.78, 0.71, and 0.71; ρ < 0.0001). Cross-sectional dimensions such as area, circumference, and transverse diameter showed a higher positive correlation with image noise than body weight for pediatric low dose abdominal CT

  3. Spatial variation of the section sensitivity profile in helical CT

    International Nuclear Information System (INIS)

    Katsuta, Shoichi; Hanai, Kouzou; Kunii, Takeo; Kimura, Haruki; Imabayashi, Wataru; Muramatsu, Yoshihisa

    1999-01-01

    The section sensitivity profile (SSP) is adequate to express the properties of helical CT images. Although SSP measurement has been performed only at the center of the imaging field, we applied it to off-center positions using a metal bead and controlled tracking technique. The experimental results indicated that SSP curves vary in the imaging field according to the relative position of the x-ray focus. The results were in agreement with computer simulations. (author)

  4. THIN-WALLED CROSS SECTION SHAPE INFLUENCE ON STEEL MEMBER RESISTANCE

    Directory of Open Access Journals (Sweden)

    Elżbieta Urbańska-Galewska

    2016-03-01

    Full Text Available This work describes why trending thin-walled technology is achieving popularity in steel construction sector. A purpose of this article is to present the influence of the cold-formed element cross-section shape on an axial compression and a bending moment resistance. The authors have considered four different shapes assuming constant section area and thickness. Calculations were based on three different steel grades taking into account local, distortional and overall buckling. The results are presented in a tabular and a graphical way and clearly confirm that cross-section forming distinctly impact the cold-formed member resistance. The authors choose these cross-sections that work better in compression state and the other (those slender and high that function more efficiently are subjected to bending.

  5. Internal-external flow integration for a thin ejector-flapped wing section

    Science.gov (United States)

    Woolard, H. W.

    1979-01-01

    Thin airfoil theories of an ejector flapped wing section are reviewed. The global matching of the external airfoil flow with the ejector internal flow and the overall ejector flapped wing section aerodynamic performance are examined. Mathematical models of the external and internal flows are presented. The delineation of the suction flow coefficient characteristics are discussed. The idealized lift performance of an ejector flapped wing relative to a jet augmented flapped wing are compared.

  6. Automated method for relating regional pulmonary structure and function: integration of dynamic multislice CT and thin-slice high-resolution CT

    Science.gov (United States)

    Tajik, Jehangir K.; Kugelmass, Steven D.; Hoffman, Eric A.

    1993-07-01

    We have developed a method utilizing x-ray CT for relating pulmonary perfusion to global and regional anatomy, allowing for detailed study of structure to function relationships. A thick slice, high temporal resolution mode is used to follow a bolus contrast agent for blood flow evaluation and is fused with a high spatial resolution, thin slice mode to obtain structure- function detail. To aid analysis of blood flow, we have developed a software module, for our image analysis package (VIDA), to produce the combined structure-function image. Color coded images representing blood flow, mean transit time, regional tissue content, regional blood volume, regional air content, etc. are generated and imbedded in the high resolution volume image. A text file containing these values along with a voxel's 3-D coordinates is also generated. User input can be minimized to identifying the location of the pulmonary artery from which the input function to a blood flow model is derived. Any flow model utilizing one input and one output function can be easily added to a user selectable list. We present examples from our physiologic based research findings to demonstrate the strengths of combining dynamic CT and HRCT relative to other scanning modalities to uniquely characterize pulmonary normal and pathophysiology.

  7. Evaluation of living renal donors: accuracy of three-dimensional 16-section CT

    Energy Technology Data Exchange (ETDEWEB)

    Rastogi, N; Sahani, D.V.; Blake, M.A.; Ko, D.C.; Mueller, P.R. [Massachusetts General Hospital, Boston, MA (United States). Dept. of Radiology

    2006-07-15

    Purpose: To retrospectively assess the sensitivity and specificity of three-dimensional (3D) 16-section computed tomography (CT) in the evaluation of vessels, pelvicalyceal system, and ureters in living renal donors, with surgical findings as the reference standard. Materials and methods: This was a HIPAA-compliant study. Institutional review board approval was obtained for the review of subjects' medical records and data analysis, with waiver of informed consent. Forty-six renal donors (18 men, 28 women; mean age, 42 years) were examined with 16-section CT. Two blinded reviewers independently studied renal vascular and urographic anatomy of each donor CT scans by fist using 3D images alone, then transverse images alone, and finally transverse and 3D data set. Image quality, degree of diagnostic confidence, and time used for review were recorded. Sensitivity and specificity were calculated. Results: For 3D images, transverse images, and transverse in conjunction with 3D data sets, the respective sensitivity and specificity of CT in evaluation of accessory arteries by reviewer 1 were 100% and 100%, 89% and 100%, and 100% and 100%, and those by reviewer 2 were 89% and 97%, 89% and 100%, and 89% and 100%; the respective sensitivity and specificity in evaluation of venous anomalies by reviewer 1 were 100% and 98%, 100% and 98%, and 100% and 98%, and those by reviewer 2 were 100% and 98%, 100% and 95%, and 100% and 98%. For focused comprehensive assessment of renal donors with 3D scans alone, a reviewer on average (average of reviewers 1 and 2) used 2.4 minutes per scan, demonstrated full confidence in 93%, and rated the quality as excellent in 76%. Conclusion: For focused assessment of renal vascular and urographic anatomy, review of 3D data set alone provides high sensitivity and specificity with regard to findings seen at surgery. (author)

  8. Evaluation of living renal donors: accuracy of three-dimensional 16-section CT

    International Nuclear Information System (INIS)

    Rastogi, N; Sahani, D.V.; Blake, M.A.; Ko, D.C.; Mueller, P.R.

    2006-01-01

    Purpose: To retrospectively assess the sensitivity and specificity of three-dimensional (3D) 16-section computed tomography (CT) in the evaluation of vessels, pelvicalyceal system, and ureters in living renal donors, with surgical findings as the reference standard. Materials and methods: This was a HIPAA-compliant study. Institutional review board approval was obtained for the review of subjects' medical records and data analysis, with waiver of informed consent. Forty-six renal donors (18 men, 28 women; mean age, 42 years) were examined with 16-section CT. Two blinded reviewers independently studied renal vascular and urographic anatomy of each donor CT scans by fist using 3D images alone, then transverse images alone, and finally transverse and 3D data set. Image quality, degree of diagnostic confidence, and time used for review were recorded. Sensitivity and specificity were calculated. Results: For 3D images, transverse images, and transverse in conjunction with 3D data sets, the respective sensitivity and specificity of CT in evaluation of accessory arteries by reviewer 1 were 100% and 100%, 89% and 100%, and 100% and 100%, and those by reviewer 2 were 89% and 97%, 89% and 100%, and 89% and 100%; the respective sensitivity and specificity in evaluation of venous anomalies by reviewer 1 were 100% and 98%, 100% and 98%, and 100% and 98%, and those by reviewer 2 were 100% and 98%, 100% and 95%, and 100% and 98%. For focused comprehensive assessment of renal donors with 3D scans alone, a reviewer on average (average of reviewers 1 and 2) used 2.4 minutes per scan, demonstrated full confidence in 93%, and rated the quality as excellent in 76%. Conclusion: For focused assessment of renal vascular and urographic anatomy, review of 3D data set alone provides high sensitivity and specificity with regard to findings seen at surgery. (author)

  9. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  10. Paleoradiology: advanced CT in the evaluation of nine Egyptian mummies.

    Science.gov (United States)

    Hoffman, Heidi; Torres, William E; Ernst, Randy D

    2002-01-01

    Axial thin-collimation state-of-the-art spiral computed tomography (CT) was combined with sagittal and coronal reformatting, three-dimensional (3D) reconstruction, and virtual "fly-through" techniques to nondestructively study nine Egyptian mummies. These techniques provided important paleopathologic and historical information about mummification techniques, depicted anatomy in the most informative imaging plane, illustrated the soft-tissue preservation and physical appearance of mummies in superb detail, and generated an intriguing virtual tour through hollow mummified remains without harming the specimens themselves. Images generated with these methods can help archaeologists and Egyptologists understand these fascinating members of mankind and can serve as adjunct visual aids for laypersons who are interested in mummies. CT has emerged as the imaging modality of choice for the examination of Egyptian mummies due to its noninvasive cross-sectional nature and inherently superior contrast and spatial resolution. As multi-detector row CT and postprocessing tools evolve, the capabilities and applications of CT will continue to proliferate, attesting to the expanded versatility and utility of CT as a noninvasive research tool in the multidisciplinary study of Egyptian mummies. Copyright RSNA, 2002

  11. Imaging of patent foramen ovale with 64-section multidetector CT.

    Science.gov (United States)

    Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C

    2008-11-01

    To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1, 1 cm to 2 cm; grade 3, >2 cm). In addition, 23 patients who underwent both modalities were compared (Student t test and linear regression analysis). A difference with P patent at the entry into the right atrium (PFO) in 62 patients (61.4% of patients with flap valve, 23.5% of total patients). A left-to-right shunt was detected in 44 (16.7% of total) patients (grade 1, 61.4%; grade 2, 34.1%; grade 3, 4.5%). No shunt was seen in patients without a flap valve. Mean length of PFO tunnel was 7.1 mm in 44 patients with a shunt and 12.1 mm in 57 patients with a flap valve without a shunt (P < .0001). In patients with a tunnel length of 6 mm or shorter, 92.6% of the shunts were seen. ASA was seen in 11 (4.2%) patients; of these patients, a shunt was seen in seven (63.6%). In 23 patients who underwent CT angiography and TEE, both modalities showed a PFO shunt in seven. Multidetector CT provides detailed anatomic information about size, morphologic features, and shunt grade of the PFO. Shorter tunnel length and septal aneurysms are frequently associated with left-to-right shunts in patients with PFO. (c) RSNA, 2008.

  12. Detailed sectional anatomy of the spine

    International Nuclear Information System (INIS)

    Rauschning, W.

    1985-01-01

    Morphologic studies on the human spine constitute a special challenge because of the spine's complex topographic anatomy and the intimate relationship between the supporting skeleton and the contiguous soft tissues (muscles, discs, joint capsules) as well as the neurovascular contents of the spinal canal and intervertebral foramina. The improving resolution and multiplanar image reformatting capabilities of modern CT scanners call for accurate anatomic reference material. Such anatomic images should be available without distortion, in natural colors, and in considerable detail. The images should present the anatomy in the correct axial, sagittal, and coronal planes and should also be sufficiently closely spaced so as to follow the thin cuts of modern CT scanners. This chapter details one of several recent attempts to correlate gross anatomy with the images depicted by high-resolution CT. The methods of specimen preparation, sectioning, and photographing have been documented elsewhere

  13. Sectional depiction of the pelvic floor by CT, MR imaging and sheet plastination: computer-aided correlation and 3D model

    Energy Technology Data Exchange (ETDEWEB)

    Beyersdorff, D.; Taupitz, M.; Hamm, B. [Dept. of Radiology, Humboldt Univ., Berlin (Germany); Schiemann, T. [Inst. for Mathematics and Computer Science in Medicine, University of Hamburg (Germany); Kooijman, H. [Philips Medical Systems, Hamburg (Germany); Nicolas, V. [Dept. of Radiology and Nuclear Medicine, BG Kliniken Bergmannsheil, Bochum (Germany)

    2001-04-01

    The structures of the pelvic floor are clinically important but difficult to assess. To facilitate the understanding of the complicated pelvic floor anatomy on sectional images obtained by CT and MR imaging, and to make the representation more vivid, a computer-aided 3D model was created from a male and a female torso to develop a teaching tool. A male and a female cadaver torso were investigated by means of CT, MR imaging, and serial-section sheet plastination. A 3D reconstruction of the pelvic floor and adjacent structures was performed by fusion of CT and MR imaging data sets with sheet plastination sections. Corresponding sections from all three methods could be compared and visualized in their 3D context. Sheet plastination allows distinction of connective tissue, muscles, and pelvic organs down to a microscopic level. In combination with CT, MR imaging, and sheet plastination a 3D model of the pelvic floor offers a better understanding of the complex pelvic anatomy. This knowledge may be applied in the diagnostic imaging of urinary incontinence or prolapse and prior to prostate surgery. (orig.)

  14. Usual interstitial pneumonia and non-specific interstitial pneumonia: serial thin-section CT findings correlated with pulmonary function

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Yeon Joo; Lee, Kyung Soo; Chung, Man Pyo; Chung Myung Jin; Han, Joung Ho [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Mueller, Nestor L. [University of British Columbia, Vancouver (Canada); Colby, Thomas V. [Mayo Clinic Scottsdale, Scottsdale (United States); Kim, Seon Woo [Samsung Medical Center, Seoul (Korea, Republic of)

    2005-09-15

    We wanted to demonstrate and compare the serial high-resolution CTs (HRCT) and the pulmonary function test (PFT) findings of the usual interstitial pneumonia (UIP) and the non-specific interstitial pneumonia (NSIP). The serial HRCT scans and the PFT results were retrospectively analysed and compared for 35 patients having UIP without significant honeycombing (UIP-w/o hc, < 5% of honeycombing at CT), 35 patients having UIP with honeycombing (UIP-w/i hc, {>=} 5% of honeycombing), and 25 patients with NSIP. The mortality rates were also compared. Follow-up CT scans were available in 75 patients (29 UIP-w/o hc patients, 22 UIP-w/i hc patients and 24 NSIP patients) and the follow-up periods ranged from 150 to 2,370 days. The initial and follow-up PFT data were available for 71 patients. On the initial CT, significant differences were present between the UIP-w/i hc patients and both the UIP-w/o hc patients and the NSIP patients in the overall extent, ground-glass opacity (GGO) away from the reticulation, reticulation and honeycombing (all {rho} < 0.05). Improvement was noticed in five (17%) of 29 UIP-w/o hc patients, none of 22 UIP-w/i hc patients, and 9 (37%) of 24 NSIP patients; deterioration was noted in six (21%) UIP-w/o hc patients, two (9%) UIP-w/i hc patients and three (13%) NSIP patients ({rho} 0.044 between UIP-w/o and UIP-w/i hc; {rho} = 0.637 between UIP-w/o hc and NSIP; {rho} = 0.007 between UIP-w/i hc and NSIP). The serial changes of the pulmonary function in the NSIP patients were different from those noted for the UIP-w/i hc and UIP-w/o hc patients ({rho} = 0.440 between UIP-w/o and UIP-w/i hc; {rho} = 0.022 between UIP-w/o hc and NSIP; {rho} =0.003 between UIP-w/i hc and NSIP). Five (14%) of the 35 patients with UIP-w/o hc, 16 (46%) of the 35 patients with UIP-w/i hc and three (12%) of the 25 patients with NSIP died ({rho} = 0.002, comparison for the three groups). On CT, NSIP and UIP-w/o hc patients have similar patterns of parenchymal abnormalities and

  15. Oxygen-enhanced MRI vs. quantitatively assessed thin-section CT: Pulmonary functional loss assessment and clinical stage classification of asthmatics

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1100, Shimogatou, Chuo, Yamanashi, 409-3898 (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2 Minatojima Minamimachi Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Takenaka, Daisuke; Matsumoto, Sumiaki; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan)

    2011-01-15

    Purpose: The purpose of this study was to prospectively compare the efficacy of oxygen-enhanced MR imaging (O{sub 2}-enhanced MRI) and CT for pulmonary functional loss assessment and clinical stage classification of asthmatics. Materials and methods: O{sub 2}-enhanced MRI, CT and %FEV{sub 1} measurement were used 34 consecutive asthmatics classified into four stages ('Mild Intermittent [n = 7]', 'Mild Persistent [n = 8], 'Moderate Persistent [n = 14]' and 'Severe Persistent [n = 5]'). Relative enhancement ratio maps for every subject were generated, and determine mean relative enhancement ratios (MRERs). Mean lung density (MLD) and the airway wall area (WA) corrected by body surface area (WA/BSA) were also measured on CT. To compare the efficacy of the two methods for pulmonary functional loss assessment, all indexes were correlated with %FEV{sub 1}. To determine the efficacy of the two methods for clinical stage classification, all parameters for the four clinical stages were statistically compared. Results: %FEV{sub 1} showed fair or moderate correlation with all parameters (0.15 {<=} r{sup 2} {<=} 0.30, p < 0.05). WA, WA/BSA and MRER of the 'Severe Persistent' group were significantly larger than those of 'Mild Intermittent' and 'Mild Persistent' groups (p < 0.05), and MRER of the 'Moderate Persistent' group significantly lower than that of the 'Mild Intermittent' group (p < 0.05). Conclusion: O{sub 2}-enhanced MRI is as effective as CT for pulmonary functional loss assessment and clinical stage classification of asthmatics.

  16. Detection of thin wall regions of unruptured cerebral aneurysms by ECG synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 slices per rotation CT

    International Nuclear Information System (INIS)

    Fujita, Shigekiyo

    2004-01-01

    The objective of this study was to evaluate the capability of electrocardiogram (ECG) synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 sequence MD-CT to detect weak portions of unruptured cerebral aneurysm. 4D-CT angiography of unruptured cerebral aneurysms was performed on 26 patients, 28 cerebral aneurysms, using 16 sequence MD-CT (GE, HiLight Matrix II). Contrast material of iodine (300 mg/ml) was injected over 30 sec period into the ante-cubital vein with a rate of 0.06 ml/Kg/sec. ECG synchronous reconstruction images (10 images at intervals of 10% between R-R of ECG) were generated (GE, Workstation Advantage 4.1). After careful inspection of the wall motion of an aneurysm from many aspects, cine images were made from several directions. Acquisition of data required 9 seconds, total volume data were generated within 15 minutes, and ECG synchronous reconstruction image processing was performed in about 5 minutes. Animation creation for one direction was completed within one minute. Even in 3-mm aneurysms, changes of its form and size within a heartbeat were fully observed. Timing of maximum and minimum sizes were also recognized. The pulsatile changes and nipple extent, bleb, daughter, and dome of aneurysms were well visualized. The projecting motion of the pulsatory enlargement of nipple was detected in nine cases, and definite increases in bleb sizes were detected in five cases. Since the easily reptured thin walled portion of a cerebral aneurysm can be recognized by this method, 4D-CT angiography is likely to become indispensable in judging how to cope with unruptured cerebral aneurysms, in deciding whether to operate or observe. (author)

  17. CT finding of ruptured splenic artery aneurysm after cesarean section : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Chang Woo; Kim, Hee Jin [CHA Medical College, Pundang CHA Gerneral Hospital Sungnam, (Korea, Republic of)

    2000-03-01

    Spontaneous rupture of a splenic artery aneurysm during puerperium is rare and is due to the non-specific clinical appearance, diagnosis is difficult. We describe a case of spontaneous rupture of splenic artery aneurysm after a Cesarean section. CT showed high-density ascites localized in the lesser sac and left retroperitoneum.

  18. CT finding of ruptured splenic artery aneurysm after cesarean section : a case report

    International Nuclear Information System (INIS)

    Ryu, Chang Woo; Kim, Hee Jin

    2000-01-01

    Spontaneous rupture of a splenic artery aneurysm during puerperium is rare and is due to the non-specific clinical appearance, diagnosis is difficult. We describe a case of spontaneous rupture of splenic artery aneurysm after a Cesarean section. CT showed high-density ascites localized in the lesser sac and left retroperitoneum

  19. Iron melt flow in thin-walled sections using vertically parted moulds

    DEFF Research Database (Denmark)

    Larsen, Per; Tiedje, Niels

    2004-01-01

    gating systems are used small changes in the casting conditions can change the flow patterns radically. Flow in thin walled sections is not only important in thin walled part. This is illustrated with a brake disc as example. 3 different layouts have been made. The filling sequences have been recorded...... sizes of the dynamic and braking forces in the gating system.......Reducing the fuel consumption of vehicles can be done in many ways. A general way of doing it, is to reduce the weight as it is applicable together with all other means of saving fuel. Even though iron castings have been used in cars from the first car ever build, a big potential still exist...

  20. Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices

    Directory of Open Access Journals (Sweden)

    R Bernhardt

    2012-04-01

    Full Text Available Histological imaging is still considered the gold standard for analysing bone formation around metallic implants. Generally, a limited number of histological sections per sample are used for the approximation of mean values of peri-implant bone formation. In this study we compared statistically the results of bone-implant contact (BIC and bone-implant volume (BIV obtained by histological sections, with those obtained by X-ray absorption images from synchrotron radiation micro-computed tomography (SRµCT using osseointegrated screw-shaped implants from a mini-pig study. Comparing the BIC results of 3-4 histological sections per implant sample with the appropriate 3-4 SRµCT slices showed a non-significant difference of 1.9 % (p = 0.703. The contact area assessed by the whole 3D information from the SRµCT measurement in comparison to the histomorphometric results showed a non-significant difference in BIC of 4.9 % (p = 0.171. The amount of the bone-implant volume in the histological sections and the appropriate SRµCT slices showed a non-significant difference by only 1.4 % (p = 0.736 and also remains non-significant with 2.6 % (p = 0.323 using the volumetric SRµCT information. We conclude that for a clinical evaluation of implant osseointegration with histological imaging at least 3-4 sections per sample are sufficient to represent the BIC or BIV for a sample. Due to the fact that in this study we have found a significant intra-sample variation in BIC of up to ± 35 % the selection of only one or two histological sections per sample may strongly influence the determined BIC.

  1. Study of CT Scan Flooding System at High Temperature and Pressure

    Science.gov (United States)

    Chen, X. Y.

    2017-12-01

    CT scan flooding experiment can scan micro-pore in different flooding stages by the use of CT scan technology, without changing the external morphology and internal structure of the core, and observe the distribution characterization in pore medium of different flooding fluid under different pressure.thus,it can rebuilt the distribution images of oil-water distribution in different flooding stages. However,under extreme high pressure and temperature conditions,the CT scan system can not meet the requirements. Container of low density materials or thin shell can not resist high pressure,while high density materials or thick shell will cause attenuation and scattering of X-ray. The experiment uses a simple Ct scanning systems.X ray from a point light source passing trough a micro beryllium shell on High pressure stainless steal container,continuously irradiates the core holder that can continuously 360° rotate along the core axis. A rare earth intensifying screen behind the core holder emitting light when irradiated with X ray can show the core X ray section image. An optical camera record the core X ray images through a transparency high pressure glazing that placed on the High pressure stainless steal container.Thus,multiple core X ray section images can reconstruct the 3D core reconstruction after a series of data processing.The experiment shows that both the micro beryllium shell and rare earth intensifying screen can work in high temperature and high pressure environment in the stainless steal container. This way that X-ray passes through a thin layer of micro beryllium shell , not high pressure stainless steal shell,avoid the attenuation and scattering of X-ray from the container shell,while improving the high-pressure experiment requirements.

  2. A technique for the quantification of the 3D connectivity of thin articulations in bony sutures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Hojjat, Seyed-Parsa; Whyne, Cari M

    2010-04-19

    The anatomy and development of cranial and facial sutures have been studied in detail using histological sections, 2D radiographs and more recently CT imaging. However, little attention has been paid to evaluating and quantifying the connectivity of these thin cortical bone articulations. More recent technological advances such as micro-CT imaging has the potential to be used to provide quantitative measurements of 3D connectivity in bony articulations. This study presents a new technique for quantifying the connectivity of bony projections inside cranial and facial sutures using a combination of skeletonization, thinning algorithms and 3D intensity mapping. The technique is demonstrated in five sutures through semi-automated analysis and image processing of microCT scans. In the sagittal, coronal and frontozygomatic sutures an average bone connectivity of 6.6-11.6% was found with multiple bony projections providing an interlocking structure between adjacent bones. Much higher bone connectivity was present in the zygomaticotemporal and zygomaticomaxillary sutures (22.7-37.4%) with few bony projections. This method combining microCT scanning and image processing techniques was successfully used to quantify the connectivity of thin bone articulations and allowed detailed assessment of sutural fusion in 3D. The wider application of this technique may allow quantification of connectivity in other structures, in particular fracture healing of long bones. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. Reappraisal of CT-grading of subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Nishizawa, Yoshihiko; Kanaya, Haruyuki; Sasaki, Tomio

    1992-01-01

    Delayed ischemic neurological deficit (DIND) after the rupture of cerebral aneurysm remains of the most difficult problems encountered by neurosurgeons. Since the introduction of CT scanning, its clinical application has clarified a close relationship between DIND and the features of subarachnoid hemorrhage (SAH) on CT images. Fisher et al proposed a grading system for SAH based on CT equipment used in the 1980s. Using third-generation CT equipment, we developed a new SAH-grading system to predict the incidence and severity of DIND more precisely. SAH in 109 patients were retrospectively classified according to the CT findings regarding location and density as THIN, THICK, and PACKED (or DENSE). In the THIN group, no DIND appeared. In 44% of patients with THICK group, DIND developed although it was reversible in 75%. On the other hand, DIND was irreversible in 70% of the 56% of PACKEND (or DENSE) group in whom it developed. Moreover, if sequential CT scan demonstrated decrease of the size and density of the SAH, DIND may rarely developed. We therefore conclude that, in order to assess the risk of DIND more precisely, it is very important to obtain repeat CT scans before operation. (author)

  4. New reconstruction algorithm in helical-volume CT

    International Nuclear Information System (INIS)

    Toki, Y.; Rifu, T.; Aradate, H.; Hirao, Y.; Ohyama, N.

    1990-01-01

    This paper reports on helical scanning that is an application of continuous scanning CT to acquire volume data in a short time for three-dimensional study. In a helical scan, the patient couch sustains movement during continuous-rotation scanning and then the acquired data is processed to synthesize a projection data set of vertical section by interpolation. But the synthesized section is not thin enough; also, the image may have artifacts caused by couch movement. A new reconstruction algorithm that helps resolve such problems has been developed and compared with the ordinary algorithm. The authors constructed a helical scan system based on TCT-900S, which can perform 1-second rotation continuously for 30 seconds. The authors measured section thickness using both algorithms on an AAPM phantom, and we also compared degree of artifacts on clinical data

  5. Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakaura, Takeshi; Iyama, Yuji; Kidoh, Masafumi; Yokoyama, Koichi [Amakusa Medical Center, Diagnostic Radiology, Amakusa, Kumamoto (Japan); Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Oda, Seitaro; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto (Japan); Tokuyasu, Shinichi [Philips Electronics, Kumamoto (Japan); Harada, Kazunori [Amakusa Medical Center, Department of Surgery, Kumamoto (Japan)

    2016-03-15

    The purpose of this study was to evaluate the utility of iterative model reconstruction (IMR) in brain CT especially with thin-slice images. This prospective study received institutional review board approval, and prior informed consent to participate was obtained from all patients. We enrolled 34 patients who underwent brain CT and reconstructed axial images with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and IMR with 1 and 5 mm slice thicknesses. The CT number, image noise, contrast, and contrast noise ratio (CNR) between the thalamus and internal capsule, and the rate of increase of image noise in 1 and 5 mm thickness images between the reconstruction methods, were assessed. Two independent radiologists assessed image contrast, image noise, image sharpness, and overall image quality on a 4-point scale. The CNRs in 1 and 5 mm slice thickness were significantly higher with IMR (1.2 ± 0.6 and 2.2 ± 0.8, respectively) than with FBP (0.4 ± 0.3 and 1.0 ± 0.4, respectively) and HIR (0.5 ± 0.3 and 1.2 ± 0.4, respectively) (p < 0.01). The mean rate of increasing noise from 5 to 1 mm thickness images was significantly lower with IMR (1.7 ± 0.3) than with FBP (2.3 ± 0.3) and HIR (2.3 ± 0.4) (p < 0.01). There were no significant differences in qualitative analysis of unfamiliar image texture between the reconstruction techniques. IMR offers significant noise reduction and higher contrast and CNR in brain CT, especially for thin-slice images, when compared to FBP and HIR. (orig.)

  6. CT diagnosis of pancreatic carcinoma and chronic pancreatitis

    International Nuclear Information System (INIS)

    Luan Baoqing; Jin Erhu; Zhang Lizhen; Jiang Haibin

    1997-01-01

    To improve the diagnostic accuracy of pancreatic carcinoma and chronic pancreatitis. The CT findings of 154 cases with pancreatic carcinoma, chronic pancreatitis and mis-diagnosed other pancreatic diseases proven clinically and pathologically were analysed. Slice thickness of 8 mm and slice interval of 8 mm were used and thin-section scan and enhancement study were performed in some cases. The main signs in degassing and differential diagnosis between pancreatic carcinoma and chronic pancreatitis included: (1) focal or diffuse enlargement and density abnormality of pancreas; (2) dilated common bile duct was suddenly obstructed, peripancreatic blood vessels were invaded and cancerous thrombus was revealed, enlargement of abdominal lymph nodes and metastasis in the liver were discovered; (3) calcium deposit in the pancreatic duct area and dilated pancreatic duct which passed through the lesion or not; (4) presence and location of pancreatic cyst and its relationship to pancreatic contour. CT is the imaging modality of choice in the diagnosis of pancreatic carcinoma and chronic pancreatitis at present. The diagnostic accuracy of CT was over 90% in this series

  7. Analysis of moderately thin-walled beam cross-sections by cubic isoparametric elements

    DEFF Research Database (Denmark)

    Høgsberg, Jan Becker; Krenk, Steen

    2014-01-01

    In technical beam theory the six equilibrium states associated with homogeneous tension, bending, shear and torsion are treated as individual load cases. This enables the formulation of weak form equations governing the warping from shear and torsion. These weak form equations are solved...... numerically by introducing a cubic-linear two-dimensional isoparametric element. The cubic interpolation of this element accurately represents quadratic shear stress variations along cross-section walls, and thus moderately thin-walled cross-sections are effectively discretized by these elements. The ability...

  8. Cervical lymph node metastasis of oral squamous cell carcinomas. CT enhancement and histopathological evaluations

    Energy Technology Data Exchange (ETDEWEB)

    Etoh, Yohei; Kimura, Takuji; Sasaki, Akira; Kishimoto, Koji; Matsumura, Tomohiro; Kishi, Kanji [Okayama Univ. (Japan). Dental School

    2000-06-01

    A comparison of the results of histopathological and enhanced CT examinations were carried out for 88 patients with oral squamous cell carcinomas who underwent neck dissection. CT scanning (5-mm thick section) images obtained during bolus/drip injection of Iopamidol were routinely taken through the neck. Ninety-two of 1634 nodes were histologically diagnosed as metastatic. Low density areas surrounding enhancement rims were metastatic nodal central necrosis or keratinization. Enhanced areas in many metastatic nodes were considered to be lymphatic architecture, not metastatic masses especially in the avascular keratinization. Enhanced CT produced accurate information of lymph node size, location, shape, grouping and spread from nodes to adjacent structures. However, it was considered that not every metastatic lymph node should show enlargement and/or enhancement. Improved assessment of solid metastatic features of lymph nodes (shape, size, and involvement) may be achieved with the aid of thin-thickness CT. (author)

  9. Cervical lymph node metastasis of oral squamous cell carcinomas. CT enhancement and histopathological evaluations

    International Nuclear Information System (INIS)

    Etoh, Yohei; Kimura, Takuji; Sasaki, Akira; Kishimoto, Koji; Matsumura, Tomohiro; Kishi, Kanji

    2000-01-01

    A comparison of the results of histopathological and enhanced CT examinations were carried out for 88 patients with oral squamous cell carcinomas who underwent neck dissection. CT scanning (5-mm thick section) images obtained during bolus/drip injection of Iopamidol were routinely taken through the neck. Ninety-two of 1634 nodes were histologically diagnosed as metastatic. Low density areas surrounding enhancement rims were metastatic nodal central necrosis or keratinization. Enhanced areas in many metastatic nodes were considered to be lymphatic architecture, not metastatic masses especially in the avascular keratinization. Enhanced CT produced accurate information of lymph node size, location, shape, grouping and spread from nodes to adjacent structures. However, it was considered that not every metastatic lymph node should show enlargement and/or enhancement. Improved assessment of solid metastatic features of lymph nodes (shape, size, and involvement) may be achieved with the aid of thin-thickness CT. (author)

  10. Thoracic manifestation of Wegener's granulomatosis: CT findings in 30 patients

    International Nuclear Information System (INIS)

    Lee, Kyung Soo; Kim, Tae Sung; Kim, Eun A.; Fujimoto, Kiminori; Moriya, Hiroshi; Watanabe, Hideyuki; Tateishi, Ukihide; Ashizawa, Kazuoto; Johkoh, Takeshi; Kwon, O. Jung

    2003-01-01

    Our objective was to describe the CT findings of thoracic Wegener's granulomatosis. At presentation, both conventional and thin-section CT scans were available in 30 patients with Wegener's granulomatosis. Serial CT scans (range of intervals: 1-25 months, mean 4.5 months) were available in 20 patients. The initial and follow-up CT scans were analyzed retrospectively by two observers in terms of pattern and extent of parenchymal and airway lesions. Positive CT findings were seen in 29 of 30 (97%) patients at initial presentation. The most common pattern was nodules or masses seen in 27 of 30 (90%) patients. They were multiple in 23 of 27 (85%) patients, bilateral in 18 (67%), subpleural in 24 (89%), and peribronchovascular in 11 (41%) in distribution. Bronchial wall thickening in the segmental or subsegmental bronchi was seen in 22 (73%) patients. Large airways were also abnormal in 9 (30%) patients. Patchy areas of consolidation and ground-glass opacity were seen in 7 (23%) patients, respectively. In 17 of 20 (85%) patients in whom follow-up CT scans were available, the parenchymal or airway lesion showed complete or partial improvement with treatment. The CT findings of Wegener's granulomatosis, although multiple and variable, consist mainly of bilateral subpleural or peribronchovascular nodules or masses and bronchial wall thickening in the segmental or subsegmental bronchi. Parenchymal and airway lesions improve with treatment in most patients. (orig.)

  11. Comparative study between ultrahigh spatial frequency algorithm and high spatial frequency algorithm in high-resolution CT of the lungs

    International Nuclear Information System (INIS)

    Oh, Yu Whan; Kim, Jung Kyuk; Suh, Won Hyuck

    1994-01-01

    To date, the high spatial frequency algorithm (HSFA) which reduces image smoothing and increases spatial resolution has been used for the evaluation of parenchymal lung diseases in thin-section high-resolution CT. In this study, we compared the ultrahigh spatial frequency algorithm (UHSFA) with the high spatial frequency algorithm in the assessment of thin section images of the lung parenchyma. Three radiologists compared the UHSFA and HSFA on identical CT images in a line-pair resolution phantom, one lung specimen, 2 patients with normal lung and 18 patients with abnormal lung parenchyma. Scanning of a line-pair resolution phantom demonstrated no difference in resolution between two techniques but it showed that outer lines of the line pairs with maximal resolution looked thicker on UHSFA than those on HSFA. Lung parenchymal detail with UHSFA was judged equal or superior to HSFA in 95% of images. Lung parenchymal sharpness was improved with UHSFA in all images. Although UHSFA resulted in an increase in visible noise, observers did not found that image noise interfered with image interpretation. The visual CT attenuation of normal lung parenchyma is minimally increased in images with HSFA. The overall visual preference of the images reconstructed on UHSFA was considered equal to or greater than that of those reconstructed on HSFA in 78% of images. The ultrahigh spatial frequency algorithm improved the overall visual quality of the images in pulmonary parenchymal high-resolution CT

  12. Estimating the thickness of ultra thin sections for electron microscopy by image statistics

    DEFF Research Database (Denmark)

    Sporring, Jon; Khanmohammadi, Mahdieh; Darkner, Sune

    2014-01-01

    We propose a method for estimating the thickness of ultra thin histological sections by image statistics alone. Our method works for images, that are the realisations of a stationary and isotropic stochastic process, and it relies on the existence of statistical image-measures that are strictly m...

  13. Investigation of the Section Thickness Measurement in Tomosynthesis by Thin Metal Plate Edge Method.

    Science.gov (United States)

    Ikeno, Kaoru; Akita, Tsunemichi; Hanai, Kozo; Muramatsu, Yoshihisa

    When performing tomosynthesis, the section thickness needs to be set depending on a radiographic part and its diagnostic purpose. However, the section thickness in tomosynthesis has not been clearly defined and its measurement method has not been established yet. In this study, we devised the alternative measurement method to diagnose the section thickness using an edge of thin metal plate, and compared with the simulation results, the wire and bead method reported in the previous papers. The tomographic image of the thin metal plate positioned on the table top inclining 30 degrees, which showed the edge spread function (ESF) of each tomographic height, was taken, and then the line spread function (LSF) was obtained by differentiating the ESF image. For the next, a profile curve was plotted by maximum values of LSF of each tomographic height, and a section thickness was calculated using the full width at half maximum (FWHM) of the profile curve. The edge method derived the section thickness close to the simulation results than the other methods. Further, the section thickness depends on the thickness of the metal plate and not the material. The thickness of the metal plate suitable for the evaluation of section thickness is 0.3 mm that is equivalent to pixel size of the flat panel detector (FPD). We conducted quantitative verification to establish the measurement method of the section thickness. The edge method is a useful technique as well as the wire and bead method for grasping basic characteristics of an imaging system.

  14. Anatomy of the minor fissure: assessment with high-resolution CT and classification

    International Nuclear Information System (INIS)

    Ariyuerek, Macit O.; Yelgec, Selcuk N.; Guelsuen, Meltem; Karabulut, Nevzat

    2002-01-01

    The aims of this study were to investigate the anatomy of the minor fissure and its variations on high-resolution CT (HRCT) sections and to propose a detailed classification. The prospective study included 67 patients who were referred to CT for various indications. High-resolution CT examinations (1.5-mm collimation) were obtained through the region of the minor fissure. The CT scans were assessed for the presence, completeness, and configuration of the minor fissure. Various configurations of the minor fissure were classified into four major types, based on whether the highest portion of the middle lobe upper surface was medial (type I), lateral (type II), posterior (type III), or central (type IV). Minor fissure was identified in 65 (97%) of 67 patients, and absent in 2 (3%) cases. The fissure was incomplete in 35 (54%) of 65 patients. Type-I minor fissure is seen in 28 (43%) patients, type II in 22 (34%), type III in 5 (8%), and type IV in 2 (3%) patients. Because the majority of the fissure was absent in 8 (12%) of 35 patients with incomplete fissure, they were considered indeterminate. Comprehensive knowledge of the various configurations of the minor fissure is helpful in correct localization of a lesion and its extension. In equivocal cases, limited thin-section CT scans through the fissure delineate the anatomy more clearly and provide greater degree of precision in localizing pulmonary lesions. (orig.)

  15. Automated assessment of bone changes in cross-sectional micro-CT studies of murine experimental osteoarthritis.

    Science.gov (United States)

    Das Neves Borges, Patricia; Vincent, Tonia L; Marenzana, Massimo

    2017-01-01

    The degradation of articular cartilage, which characterises osteoarthritis (OA), is usually paired with excessive bone remodelling, including subchondral bone sclerosis, cysts, and osteophyte formation. Experimental models of OA are widely used to investigate pathogenesis, yet few validated methodologies for assessing periarticular bone morphology exist and quantitative measurements are limited by manual segmentation of micro-CT scans. The aim of this work was to chart the temporal changes in periarticular bone in murine OA by novel, automated micro-CT methods. OA was induced by destabilisation of the medial meniscus (DMM) in 10-week old male mice and disease assessed cross-sectionally from 1- to 20-weeks post-surgery. A novel approach was developed to automatically segment subchondral bone compartments into plate and trabecular bone in micro-CT scans of tibial epiphyses. Osteophyte volume, as assessed by shape differences using 3D image registration, and by measuring total epiphyseal volume was performed. Significant linear and volumetric structural modifications in subchondral bone compartments and osteophytes were measured from 4-weeks post-surgery and showed progressive changes at all time points; by 20 weeks, medial subchondral bone plate thickness increased by 160±19.5 μm and the medial osteophyte grew by 0.124±0.028 μm3. Excellent agreement was found when automated measurements were compared with manual assessments. Our automated methods for assessing bone changes in murine periarticular bone are rapid, quantitative, and highly accurate, and promise to be a useful tool in future preclinical studies of OA progression and treatment. The current approaches were developed specifically for cross-sectional micro-CT studies but could be applied to longitudinal studies.

  16. Automated assessment of bone changes in cross-sectional micro-CT studies of murine experimental osteoarthritis.

    Directory of Open Access Journals (Sweden)

    Patricia Das Neves Borges

    Full Text Available The degradation of articular cartilage, which characterises osteoarthritis (OA, is usually paired with excessive bone remodelling, including subchondral bone sclerosis, cysts, and osteophyte formation. Experimental models of OA are widely used to investigate pathogenesis, yet few validated methodologies for assessing periarticular bone morphology exist and quantitative measurements are limited by manual segmentation of micro-CT scans. The aim of this work was to chart the temporal changes in periarticular bone in murine OA by novel, automated micro-CT methods.OA was induced by destabilisation of the medial meniscus (DMM in 10-week old male mice and disease assessed cross-sectionally from 1- to 20-weeks post-surgery. A novel approach was developed to automatically segment subchondral bone compartments into plate and trabecular bone in micro-CT scans of tibial epiphyses. Osteophyte volume, as assessed by shape differences using 3D image registration, and by measuring total epiphyseal volume was performed.Significant linear and volumetric structural modifications in subchondral bone compartments and osteophytes were measured from 4-weeks post-surgery and showed progressive changes at all time points; by 20 weeks, medial subchondral bone plate thickness increased by 160±19.5 μm and the medial osteophyte grew by 0.124±0.028 μm3. Excellent agreement was found when automated measurements were compared with manual assessments.Our automated methods for assessing bone changes in murine periarticular bone are rapid, quantitative, and highly accurate, and promise to be a useful tool in future preclinical studies of OA progression and treatment. The current approaches were developed specifically for cross-sectional micro-CT studies but could be applied to longitudinal studies.

  17. The value of multislice helical CT in the diagnosis of the rib micro-fracture

    International Nuclear Information System (INIS)

    Wang Shuli; Wang Linsen; Sun Dingyuan; Deng Xin; Geng Xin; Li Jian; Liu Zhigang; Guo Lin; Jia Zhihong

    2005-01-01

    Objective: To evaluate the clinical value of MSCT with thin-section reconstruction and curved multiplanar reformation of rib micro-fracture. Methods: Thirty-eight patients suspected ribs fracture by clinical examination, which had negative appearance in X-ray film, were performed with MSCT scan with thin-section reconstructed and curved multiplanar reformation. The imaging of 5 mm, 1 mm thickness and curved reformatted imags were analysed by three groups of radiologists respectively. Results: Of the 38 patients, 26 patients were demonstrated ribs fracture with 1 mm thin-section reconstructed and curved multiplanar reformatted CT imaging, which were classified as complete fracture in 18 ribs and incomplete fracture in 41 ribs. The ends of the fractures displacement located within a distance of double-thickness of the cortex of the complete ribs fracture. With 5 mm thickness imaging, the accuracy of the diagnosis was 86.4%, 89.8% and 94.9% by three groups radiologists, respectively. Conclusion: The rib fracture is very common in clinic, the incomplete and non evident displacement complete ribs fracture are difficult to be diagnosed by plain radiography. The MSCT can produce a large range volume information scan. Thin-section reconstructed and curved multiplanar reformatted imaging should be the effective method in diagnosis of ribs fracture. The total rib pattern and location, extend of all the ribs fracture in this cases can be displayed in one scan by the curved multiplanar reformatted imaging. (authors)

  18. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  19. Utility of CT in the evaluation of pulmonary tuberculosis in patients without Aids

    International Nuclear Information System (INIS)

    Lee, K.S.; Hwang, J.W.; Chung, M.P.

    1997-01-01

    Objective. To assess the utility of CT in the evaluation of pulmonary tuberculosis in patients without AIDS. Patients and methods. Thin-section CT scans for suspicion of pulmonary tuberculosis were obtained from 226 patients. A total of 38 patients were excluded; the reasons were unavailability of final results (n=18), patient unavailability for follow-up (n=13), and coexistence of tuberculosis and aspergilloma (n=7). The results from 188 patients were used for this study. After assessing the patterns of parenchymal lesion, involved segments, and presence of cavity, bronchiectases, and bronchogenic spread of the lesion with CT, tentative diagnosis and disease activity were recorded. Results. With CT, 133 of 146 patients (91%) with tuberculosis were correctly diagnosed as having pulmonary tuberculosis whereas 32 of 42 patients (76%) without tuberculosis were correctly excluded. CT diagnosis of lung cancer (n=8), bacterial pneumonia (n=2), pulmonary metastasis (n=1), chronic hypersensitivity pneumonia (n=1) and diffuse pan-bronchiolitis (n=1) turned out to be tuberculosis. Conversely CT diagnoses of tuberculosis appeared pathologically as lung cancer (n=5), bacterial pneumonia 71/89, 80%) and inactive state (51/57, 89%) of disease respectively could be correctly differentiated by CT. Conclusion. CT can be helpful in the diagnosis of pulmonary tuberculosis in most cases. On the basis of CT findings, distinction of active from inactive disease can be made in most cases. (authors)

  20. Treatment of craniopharyngioma estimated by follow-up CT

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, T.; Ito, H.; Aizumi, S.; Yamamoto, S.; (Kanazawa Univ. (Japan). School of Medicine)

    1981-12-01

    Follow-up CT scans were taken from 12 cases of craniopharyngiomas after various treatment. Preoperative CT findings of craniopharyngiomas could be classified into three types. Type 1 was a non-enhanced or a thinly ring-like enhanced large cystic mass. Type 2 was a thickly enhanced large cystic mass with small solid mass. Type 3 was a large solid mass. Postoperative follow-up CT findings were as follows: Type 1 had a favorable postoperative course because the tumor tissues of the thin cystic wall seemed to collapse only with the procedure of cystic fluid aspiration. Recurrence frequently took place in patients of Type 2 and 3 if the tumor couldn't be radically removed or radiotherapy was not given after partial resection. Radiotherapy was most effective in these cases.

  1. Treatment of craniopharyngioma estimated by follow-up CT

    International Nuclear Information System (INIS)

    Kubota, Toshihiko; Ito, Haruhide; Aizumi, Shinichi; Yamamoto, Shinjiro

    1981-01-01

    Follow-up CT scans were taken from 12 cases of craniopharyngiomas after various treatment. Preoperative CT findings of craniopharyngiomas could be classified into three types. Type 1 was a non-enhanced or a thinly ring-like enhanced large cystic mass. Type 2 was a thickly enhanced large cystic mass with small solid mass. Type 3 was a large solid mass. Postoperative follow-up CT findings were as follows: Type 1 had a favorable postoperative course because the tumor tissues of the thin cystic wall seemed to collapse only with the procedure of cystic fluid aspiration. Recurrence frequently took place in patients of Type 2 and 3 if the tumor couldn't be radically removed or radiotherapy was not given after partial resection. Radiotherapy was most effective in these cases. (author)

  2. Atomic force microscopy imaging and 3-D reconstructions of serial thin sections of a single cell and its interior structures

    International Nuclear Information System (INIS)

    Chen Yong; Cai Jiye; Zhao Tao; Wang Chenxi; Dong Shuo; Luo Shuqian; Chen, Zheng W.

    2005-01-01

    The thin sectioning has been widely applied in electron microscopy (EM), and successfully used for an in situ observation of inner ultrastructure of cells. This powerful technique has recently been extended to the research field of atomic force microscopy (AFM). However, there have been no reports describing AFM imaging of serial thin sections and three-dimensional (3-D) reconstruction of cells and their inner structures. In the present study, we used AFM to scan serial thin sections approximately 60 nm thick of a mouse embryonic stem (ES) cell, and to observe the in situ inner ultrastructure including cell membrane, cytoplasm, mitochondria, nucleus membrane, and linear chromatin. The high-magnification AFM imaging of single mitochondria clearly demonstrated the outer membrane, inner boundary membrane and cristal membrane of mitochondria in the cellular compartment. Importantly, AFM imaging on six serial thin sections of a single mouse ES cell showed that mitochondria underwent sequential changes in the number, morphology and distribution. These nanoscale images allowed us to perform 3-D surface reconstruction of interested interior structures in cells. Based on the serial in situ images, 3-D models of morphological characteristics, numbers and distributions of interior structures of the single ES cells were validated and reconstructed. Our results suggest that the combined AFM and serial-thin-section technique is useful for the nanoscale imaging and 3-D reconstruction of single cells and their inner structures. This technique may facilitate studies of proliferating and differentiating stages of stem cells or somatic cells at a nanoscale

  3. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  4. CT findings of pulmonary edema: comparison of various causes

    International Nuclear Information System (INIS)

    Kim, Hyae Young; Im, Jung Gi; Goo, Jin Mo; Lee, Jae Kyo; Song, Jae Woo

    1999-01-01

    To access the CT findings of pulmonary edema and to compare them, according to the cause. CT findings (thin section, 20 ; thick section, 16) of pulmonary edema in 36 patients [cardiac disease (group 1, n=20), renal disease (group 2, n=13), ARDS (group 3, n=3)] were analyzed and compared. There were 21 men and 15 women ranging in age from 27 to 77 years. Distribution (even, central, or peripheral) and patterns of pulmonary edema were compared between the three groups. The distribution of edema, appearing as consolidation or ground-glass opacity, was even in 75% (n=15) of group 1, even in 46% (n=6) and central in 38% (n=5) of group 2, and peripherally predominant in 100% (n=3) of group 3. Interlobular septal thickening was seen in 80% (n=16), 69% (n=9), and 0% of group 1, 2 and 3, respectively. Centrilobular ground-glass opacity was noted in six patients. In spite of various findings and considerable overlapping of the findings of pulmonary edema, the distribution and pattern of edema differed according to the cause, and this can be helpful for differential diagnosis

  5. [Mobile CT at neurointensive sections--it is possible].

    Science.gov (United States)

    Frost, Majbritt; Stenkær, Susanne; Kellenberger, Simone; Ehlers, Lars

    2011-01-24

    Intrahospital transportation can be complicated and hazardous. Mobile computerized tomography (CT) of the head performed at the neurointensive care unit is a new technique that minimizes the need for transportation of unstable patients. Even small changes in physiological parameters can be detrimental for these patients and cause secondary injury and thus affect their prognoses. The portable CT scanner in the neurointensive care unit holds great potential, but the high price level may limit its use.

  6. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  7. Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealants.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.W.; Frencken, J.E.F.M.

    2012-01-01

    BACKGROUND: The aim of this study was to validate the micro-CT and related software against the section method using the stereomicroscope for marginal leakage assessment along the sealant-enamel interface. METHODS: Pits and fissures of the occlusal surface of 10 teeth were sealed with a

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  11. Application of CT three-dimensional reconstruction in elbow injury

    International Nuclear Information System (INIS)

    Liang Wenhua; Qian Li

    2009-01-01

    Objective: To investigate the application of multi-slice spiral CT in fracture of elbow, and to study the value of different methods of the reconstruction. Methods: Thin line cross-section spiral CT scan was carried out in 13 cases with elbow injury, three-dimensional reconstruction was completed later. Several reconstructed image quality to display f the elbow fracture and dislocation were analyzed and compared. Results: 13 cases (17) elbow trauma included humeral media epicondyle fracture, humeral external epicondyle fracture, intercondylar fracture, olecranal fracture and radial head fracture. Among them, X-ray film showed negative in three sites, showed suspect fractures in 2 cases, and only showed single fracture in 2 cases. MPR reconstruction image could not only identify the diagnosis of fracture, but also provide further multi-angle display on fracture line and the extent of articular surface involvement. Surface reconstruction technology could exclude the impact of passive elbow flexion and display elbow injury more intuitively. Conclusion The elbow fracture dislocation could be showed clearly in multi-slice spiral CT, especially for complex fractures, with unmatched advantages compared to X-ray for clinical diagnosis and treatment determination. (authors)

  12. Evaluation of colonic lesions and pitfalls in CT colonography: A systematic approach based on morphology, attenuation and mobility

    International Nuclear Information System (INIS)

    Mang, Thomas; Gryspeerdt, Stefaan; Schima, Wolfgang; Lefere, Philippe

    2013-01-01

    Computed tomographic colonography is a reliable technique for the detection and classification of neoplastic and non-neoplastic lesions of the colon. It is based on a thin-section CT dataset of the cleansed and air-distended colon, acquired in prone and supine position. Two-dimensional and 3D projections are used in combination for image interpretation. The evaluation of CT colonography datasets is based on two steps, lesion perception to detect a polyp candidate and image interpretation to correctly characterize colonic filling defects. A thorough knowledge of the morphologic and attenuation characteristics of common colonic lesions and artifacts facilitates characterization of the findings. The purpose of this review article is to give an overview of the key CT colonographic imaging criteria to correctly characterize common colorectal lesions and to identify typical pitfalls and pseudolesions

  13. Pulmonary spheral tuberculosis: features and clinical significance of spiral dynamic CT

    International Nuclear Information System (INIS)

    Xie Ruming; Ma Daqing; Li Tieyi; Chen Yi; Lu Fudong; Zhou Xinhua

    2001-01-01

    Objective: To assess the features and clinical significance of spiral dynamic CT in patients with pulmonary spheral tuberculosis. Methods: The 54 foci in 42 patients with pulmonary spheral tuberculosis were studied. Thin-sections at 2 mm thickness and 2 mm interval through the nodular center were obtained before and after administration of contrast material. Results: In 54 pulmonary spheral tuberculosis, maximum enhanced CT value in 51 (94.4%, 51/54) foci was less than 20 HU, and more than 20 HU in the other 3(5.6%, 3/54) foci. 27(50.0%, 27/54) foci showed no any enhancement, 24, (44%, 24/54) foci showed capsular enhancement, 1(1.9%, 1/54) focus showed peripheral enhancement and 2(3.7%, 2/54) foci showed extensive enhancement. The accuracy of the correct diagnosis was 25.9% in terms of plain CT and 94.4% in terms of enhanced CT scanning. The difference was significant (x 2 = 50.1, P < 0.05). The curative effect of extensive enhanced foci and peripheral enhanced foci was optimal, capsular enhanced foci was second, and non-enhanced foci was barely satisfactory. Conclusion: Spiral dynamic CT technique may improve the accuracy of diagnosing pulmonary spheral tuberculosis. No enhancement and/or capsular enhancement were suggestive of tuberculosis. The enhancing character of foci might contribute to assess the curative effect of anti-tuberculosis

  14. Combined X-ray CT and mass spectrometry for biomedical imaging applications

    Science.gov (United States)

    Schioppa, E., Jr.; Ellis, S.; Bruinen, A. L.; Visser, J.; Heeren, R. M. A.; Uher, J.; Koffeman, E.

    2014-04-01

    Imaging technologies play a key role in many branches of science, especially in biology and medicine. They provide an invaluable insight into both internal structure and processes within a broad range of samples. There are many techniques that allow one to obtain images of an object. Different techniques are based on the analysis of a particular sample property by means of a dedicated imaging system, and as such, each imaging modality provides the researcher with different information. The use of multimodal imaging (imaging with several different techniques) can provide additional and complementary information that is not possible when employing a single imaging technique alone. In this study, we present for the first time a multi-modal imaging technique where X-ray computerized tomography (CT) is combined with mass spectrometry imaging (MSI). While X-ray CT provides 3-dimensional information regarding the internal structure of the sample based on X-ray absorption coefficients, MSI of thin sections acquired from the same sample allows the spatial distribution of many elements/molecules, each distinguished by its unique mass-to-charge ratio (m/z), to be determined within a single measurement and with a spatial resolution as low as 1 μm or even less. The aim of the work is to demonstrate how molecular information from MSI can be spatially correlated with 3D structural information acquired from X-ray CT. In these experiments, frozen samples are imaged in an X-ray CT setup using Medipix based detectors equipped with a CO2 cooled sample holder. Single projections are pre-processed before tomographic reconstruction using a signal-to-thickness calibration. In the second step, the object is sliced into thin sections (circa 20 μm) that are then imaged using both matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) and secondary ion (SIMS) mass spectrometry, where the spatial distribution of specific molecules within the sample is determined. The

  15. Multi-photon vertical cross-sectional imaging with a dynamically-balanced thin-film PZT z-axis microactuator.

    Science.gov (United States)

    Choi, Jongsoo; Duan, Xiyu; Li, Haijun; Wang, Thomas D; Oldham, Kenn R

    2017-10-01

    Use of a thin-film piezoelectric microactuator for axial scanning during multi-photon vertical cross-sectional imaging is described. The actuator uses thin-film lead-zirconate-titanate (PZT) to generate upward displacement of a central mirror platform, micro-machined from a silicon-on-insulator (SOI) wafer to dimensions compatible with endoscopic imaging instruments. Device modeling in this paper focuses on existence of frequencies near device resonance producing vertical motion with minimal off-axis tilt even in the presence of multiple vibration modes and non-uniformity in fabrication outcomes. Operation near rear resonance permits large stroke lengths at low voltages relative to other vertical microactuators. Highly uniform vertical motion of the mirror platform is a key requirement for vertical cross-sectional imaging in the remote scan architecture being used for multi-photon instrument prototyping. The stage is installed in a benchtop testbed in combination with an electrostatic mirror that performs in-plane scanning. Vertical sectional images are acquired from 15 μm diameter beads and excised mouse colon tissue.

  16. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2011-01-01

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient (γ 2 = 0.86, P 2 vs. 326.3 ± 124.8 cm 2 ), mean density (-212.9 ± 53.1 HU vs. -221.1 ± 56.3 HU), and image noise (13.8 ± 2.3 vs. 13.6 ± 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  17. Hepatic and pancreatic involvement in hereditary hemorrhagic telangiectasia: quantitative and qualitative evaluation with 64-section CT in asymptomatic adult patients

    Energy Technology Data Exchange (ETDEWEB)

    Barral, Matthias; Sirol, Marc; Hamzi, Lounis; Gayat, Etienne; Boudiaf, Mourad [Hopital Lariboisiere-APHP, Department of Abdominal Imaging, Paris (France); Place, Vinciane [Hopital Lariboisiere-APHP, Department of Abdominal Imaging, Paris (France); Universite Diderot-Paris 7, UFR de Medecine, Paris (France); Borsik, Michel [Hopital Lariboisiere-APHP, Deparment of Ear, Nose and Throat, Paris (France); Soyer, Philippe [Hopital Lariboisiere-APHP, Department of Abdominal Imaging, Paris (France); Universite Diderot-Paris 7, UFR de Medecine, Paris (France); Unite 965 INSERM/Paris7, Hopital Lariboisiere-APHP, Paris (France)

    2012-01-15

    To analyse quantitatively and qualitatively asymptomatic hepatic and pancreatic involvement in hereditary haemorrhagic telangiectasia (HHT) using 64-section helical CT. The 64-section helical CT examinations of 19 patients with HHT (8 men, 11 women; mean age, 58.6 years) were quantitatively and qualitatively analysed and compared to those of 19 control subjects who were matched for age and sex. Comparisons were made using univariate analysis. Dilated and tortuous intrahepatic arterial branches was the most discriminating independent variable (P < 0.0001) and had the highest specificity (100%; 19/19; 95%CI: 82%-100%) and accuracy (97%; 37/38; 95%CI: 86%-100%) for the diagnosis of HHT. Heterogeneous enhancement of hepatic parenchyma, intrahepatic telangiectases, hepatic artery to hepatic vein shunting, hepatic artery enlargement (i.e. diameter > 6.5 mm) and portal vein enlargement (i.e. diameter > 13 mm) were other variables that strongly correlated with the presence of HHT. Intrapancreatic telangiectases and arteriovenous malformations were found in 42% and 16% of patients with HHT, respectively. Liver and pancreatic involvement in asymptomatic HHT patients is associated with myriad suggestive findings on 64-section helical CT. It can be anticipated that familiarity with these findings would result in more confident diagnosis of HHT. (orig.)

  18. Nanoscale size effects on the mechanical properties of platinum thin films and cross-sectional grain morphology

    KAUST Repository

    Abbas, K; Alaie, S; Ghasemi Baboly, M; Elahi, M M M; Anjum, Dalaver H.; Chaieb, Saharoui; Leseman, Z C

    2015-01-01

    -1700 MPa) are recorded and explained by the variable morphology. This work suggests that in addition to the in-plane grain size of thin films, the transitions in cross-sectional morphologies of the Pt films significantly affect their mechanical behavior.

  19. Cross-sectional anatomy for computed tomography

    International Nuclear Information System (INIS)

    Farkas, M.L.

    1988-01-01

    This self-study guide recognizes that evaluation and interpretation of CT-images demands a firm understanding of both cross-sectional anatomy and the principles of computed tomography. The objectives of this book are: to discuss the basic principles of CT, to stress the importance of cross-sectional anatomy to CT through study of selected cardinal transverse sections of head, neck, and trunk, to explain orientation and interpretation of CT-images with the aid of corresponding cross-sectional preparations

  20. Enhanced dual-phase spiral CT features of polypoid ampullary carcinoma

    International Nuclear Information System (INIS)

    Zeng Mengsu; Yan Fuhua; Zhou Kangrong; Chen Huiming; Chen Gang; Chen Jin

    2001-01-01

    Objective: To understand CT features of polypoid ampullary carcinoma by enhanced dual-phase spiral CT. Methods: 15 cases of polypoid ampullary carcinoma (PAC) confirmed by surgical and pathological results were studied with thin slice enhanced dual-phase spiral CT (including arterial and portal phase scanning)with retrospective analysis, the scanning parameters were 5 mm thickness and 1.0 pitch for arterial phase scanning, and 5 mm thickness and 5 mm space for portal phase scanning. Results: All cases could display an enhanced mass as local filling defect at the site of the duodenal Vater's ampulla during arterial and portal phase scanning, the tumors ranged in size from 1 cm to 5 cm with mean of 2.3 cm, all were accompanied with dilated intrahepatic and common bile duct, enlarged gallbladder and dilated pancreatic duct, except one case which had marked atrophy of the pancreatic body and tail. Conclusion: The thin slices enhanced dual-phase spiral CT could not only accurately define the level of obstruction, but also demonstrate an enhanced mass as direct CT sign of the PAC, which is crucial for diagnosis of the PAC

  1. CT of Normal Developmental and Variant Anatomy of the Pediatric Skull: Distinguishing Trauma from Normality.

    Science.gov (United States)

    Idriz, Sanjin; Patel, Jaymin H; Ameli Renani, Seyed; Allan, Rosemary; Vlahos, Ioannis

    2015-01-01

    The use of computed tomography (CT) in clinical practice has been increasing rapidly, with the number of CT examinations performed in adults and children rising by 10% per year in England. Because the radiology community strives to reduce the radiation dose associated with pediatric examinations, external factors, including guidelines for pediatric head injury, are raising expectations for use of cranial CT in the pediatric population. Thus, radiologists are increasingly likely to encounter pediatric head CT examinations in daily practice. The variable appearance of cranial sutures at different ages can be confusing for inexperienced readers of radiologic images. The evolution of multidetector CT with thin-section acquisition increases the clarity of some of these sutures, which may be misinterpreted as fractures. Familiarity with the normal anatomy of the pediatric skull, how it changes with age, and normal variants can assist in translating the increased resolution of multidetector CT into more accurate detection of fractures and confident determination of normality, thereby reducing prolonged hospitalization of children with normal developmental structures that have been misinterpreted as fractures. More important, the potential morbidity and mortality related to false-negative interpretation of fractures as normal sutures may be avoided. The authors describe the normal anatomy of all standard pediatric sutures, common variants, and sutural mimics, thereby providing an accurate and safe framework for CT evaluation of skull trauma in pediatric patients. (©)RSNA, 2015.

  2. The CT signs of intestinal volvulus

    International Nuclear Information System (INIS)

    Ji Jiansong; Wang Zufei; Xu Zhaolong; Lv Guijian; Xu Min; Zhao Zhongwei; Su Jinliang; Zhou Limin

    2005-01-01

    Objective: To improve the accuracy rate of spiral CT diagnosing intestinal volvulus. Methods: To analysis the CT findings of 9 cases of intestinal volvulus proved by operation, the main reconstruction techniques were multiplanar reformation (MPR) and sliding thin-slab maximum intensity projection (STS-MIP). Results: All the 9 cases were diagnosed accurately, the main signs were 'whirlpool' of intestine (6 cases) and vessels (9 cases),'target loop' (2 cases),'beak'(6 cases). Conclusion: 'Whirlpool' of vessels is a specific sign to diagnose intestinal volvulus, 'target loop', reduced enhancement of intestinal wall and ascites are the reliable signs to strangulated intestinal obstruction. Spiral CT and reconstructions have important value to diagnose the intestinal volvulus. (authors)

  3. Pulmonary involvement in Churg-Strauss syndrome: an analysis of CT, clinical, and pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung; Lee, Kyung Soo; Chong, Semin; Chung, Myung Jin; Yi, Chin A; Kim, Ha Young [Samsung Medical Center, Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Seoul (Korea); Chung, Man Pyo [Samsung Medical Center, Sungkyunkwan University School of Medicine, Division of Pulmonary and Critical Care Medicine, Department of Medicine, Seoul (Korea); Han, Joungho [Samsung Medical Center, Sungkyunkwan University School of Medicine, Department of Pathology, Seoul (Korea)

    2007-12-15

    We tried to assess retrospectively thin-section CT findings of Churg-Strauss syndrome (CSS) in 25 patients and to compare these findings with clinical and histopathologic findings. Of 25 patients, 19 (76%) had parenchymal abnormalities at CT; small nodules (n = 12; 63%), ground-glass opacity (n = 10; 53%), bronchial wall thickening (n = 10; 53%), and consolidation (n = 8; 42%). Parenchymal abnormalities (n = 19) were categorizable as an airway pattern in 11 and an airspace pattern in eight. Patients with an airway pattern (n = 5) had obstructive (n = 3) or combined (n = 2) PFT results, whereas those with an airspace pattern (n = 4) had restrictive (n = 3) or obstructive (n = 1) results. Parenchymal opacities at CT corresponded histologically to areas of eosinophilic pneumonia, necrotizing granulomas, and granulomatous vasculitis; small nodules to eosinophilic bronchiolitis and peribronchiolar vasculitis; and bronchial wall thickening to airway wall eosinophil and lymphocyte infiltration. Patients with airspace pattern responded more readily to treatment than those with airway pattern. CT shows lung parenchymal abnormalities in about three-quarters of CSS patients and these abnormalities can be categorized as airspace or airway patterns. This classification helps predict PFT data, underlying histopathology, and treatment response. (orig.)

  4. Pulmonary involvement in Churg-Strauss syndrome: an analysis of CT, clinical, and pathologic findings

    International Nuclear Information System (INIS)

    Kim, Yoon Kyung; Lee, Kyung Soo; Chong, Semin; Chung, Myung Jin; Yi, Chin A.; Kim, Ha Young; Chung, Man Pyo; Han, Joungho

    2007-01-01

    We tried to assess retrospectively thin-section CT findings of Churg-Strauss syndrome (CSS) in 25 patients and to compare these findings with clinical and histopathologic findings. Of 25 patients, 19 (76%) had parenchymal abnormalities at CT; small nodules (n = 12; 63%), ground-glass opacity (n = 10; 53%), bronchial wall thickening (n = 10; 53%), and consolidation (n = 8; 42%). Parenchymal abnormalities (n = 19) were categorizable as an airway pattern in 11 and an airspace pattern in eight. Patients with an airway pattern (n = 5) had obstructive (n = 3) or combined (n = 2) PFT results, whereas those with an airspace pattern (n = 4) had restrictive (n = 3) or obstructive (n = 1) results. Parenchymal opacities at CT corresponded histologically to areas of eosinophilic pneumonia, necrotizing granulomas, and granulomatous vasculitis; small nodules to eosinophilic bronchiolitis and peribronchiolar vasculitis; and bronchial wall thickening to airway wall eosinophil and lymphocyte infiltration. Patients with airspace pattern responded more readily to treatment than those with airway pattern. CT shows lung parenchymal abnormalities in about three-quarters of CSS patients and these abnormalities can be categorized as airspace or airway patterns. This classification helps predict PFT data, underlying histopathology, and treatment response. (orig.)

  5. Evaluation of solitary pulmonary metastasis of extrathoracic tumor with thin-slice computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Shiotani, Seiji; Yamada, Kouzo; Oshita, Fumihiro; Nomura, Ikuo; Noda, Kazumasa; Yamagata, Tatushi; Tajiri, Michihiko; Ishibashi, Makoto; Kameda, Youichi [Kanagawa Cancer Center, Yokohama (Japan)

    1995-10-01

    Thin-slice computed tomography (CT) images were compared with pathological findings in 9 specimens of solitary pulmonary nodules, which had been pathologically diagnosed as pulmonary metastasis of extrathoracic tumor. The thin-slice CT images were 2 mm-thick images reconstructed using a TCT-900S, HELIX (Toshiba, Tokyo) and examined at two different window and level settings. In every case, the surgical specimens were sliced transversely to correlate with the CT images. According to the image findings, the internal structure was of the solid-density type in every case, and the margin showed spiculation in 22%, notching in 67% and pleural indentation in 89%. Regarding the relationship between the pulmonary vessels and tumors, plural vascular involvement was revealed in every case. Thus, it was difficult to distinguish solitary pulmonary metastasis of extrathoracic tumor from primary lung cancer based on the thin-slice CT images. For some solitary pulmonary metastasis of extrathoracic tumor, a comprehensive diagnostic approach taking both the anamnesis and pathological findings into consideration was required. (author).

  6. Hidden Ice Worlds - Pleistocene glacigenic deposits in Essex, England. Application of the novel systematic approach to thin-section description.

    Science.gov (United States)

    Leszczynska, Karolina; Boreham, Julie; Boreham, Steve

    2013-04-01

    In the 'Hidden Ice Worlds' research project a novel systematic approach for thin-section description (Leszczynska et al., 2011) is applied to analyse the internal structure of 8 m thick periglacially disturbed sequence from the Royal Oak Pit - a small disused quarry in East Anglia, Essex, east of Chelmsford, near Danbury. Danbury Hill is situated on the south-eastern margin of the Elsterian (Anglian) till sheet. This area was glaciated only once, during the Pleistocene, Elsterian (Anglian) glaciation (480-420 ka BP), however two local ice-sheet margin fluctuations are envisaged (inter alia Turner, 1970 and others). The stratigraphical sequence of the Royal Oak Pit comprises: massive gravel, arranged in sheets, overlain by fine silty-clay and silty-sand with ripple marks and planar cross beds, overlain by a 50 cm thick unit of massive gravel gradually changing into periglacially disturbed silty-clayey-gravel with the bottom 50 cm of fine laminated silty clay. This sequence is situated on the lee side of Danbury Hill, at over 50 m OD. This is an atypical location for the periglacially disturbed deposits of such a substantial thickness (up to 8 m), which usually occur in the lower areas. The deposits at this site were investigated at a macro-scale using field-section logging, ground penetrating radar survey, clast lithology, clay mineralogy analysis and loss-on-ignition and at a micro-scale using thin-section analysis. There are two main aims of the project presented: • To describe the genesis and to discern the main processes associated with the formation of the unusually thick periglacially disturbed unit at the Danbury Hill slope and • To test the novel, tree-based, systematic approach as a guiding tool for thin for thin-section description of Quaternary deposits (Leszczynska et al., 2011). The results of the micromorphological analyses of the deposits from the Royal Oak Pit allow a new hypothesis for the origin of the sequence to be put forward. The main

  7. CT atlas of the skull base

    International Nuclear Information System (INIS)

    Inoue, Hiroshi; Kawafuchi, Jun-ichi; Takahashi, Kazukuni

    1980-01-01

    Although CT is generally used for lesions of the face, the orbit, the nasal and paranasal cavity, and the skull base, a CT atlas of these regions has not been reported. Furthermore, the skull base, that lies nearly tangential to the conventional axial plane of CT, can not be precisely evaluated on ordinary horizontal pictures. For the purpose of a clear demonstration of the skull-base structures by CT, a model human skull was investigated. The results and its clinical value have previously been reported. For the CT atlas of the skull base, three model human skulls (embedded in agar gel containing iodine in a manner previously reported) were also examined by EMI-CT1010 with a 5 mm thickness. The magnification and wide-window techniques were also used for demonstration. Ordinary-0 sections (scanning plane at 0 0 to Reid's base line), ordinary-25 sections (+25 0 to RBL), reverse-20 sections (-20 0 to RBL), reverse-80 sections (-80 0 to RBL; coronal sections), and sagittal sections were selected in order to illustrate the anatomical details of the skull base. Pictures of the inner aspect and the outer aspect of the skull base were also provided. Clinically it is very important to recognize osseous change and the relationship between the lesion and the skull base in three dimensions. In evaluating lesions of the skull base and those of the tentorial notch a two-plane CT examination (ordinary-25 sections and reverse-20 sections) is usually used. This method is useful in determining the surgical approach, for instance, to decide between a transsphenoidal approach or intracranial approach for a sellar lesion, or between a subtemporal approach, posterior fossa approach, or combined approach for a lesion of the tentorial notch. It is also helpful to make a map of the lesin on a plain craniogram using this two-plane method in some cases for radiotherapy and stereotactic brain biopsy. (author)

  8. Air CT cisternography for acoustic neurinomas

    International Nuclear Information System (INIS)

    Seki, Yojiro; Umezu, Hiromichi; Aiba, Tadashi; Takemori, Setsuko; Takebe, Hidenori

    1987-01-01

    After the introduction of the high-resolution technique in CT scan, air CT cisternography (air CTC) has been one of the most sensitive neuroradiological modalities in the detection of small acoustic neurinomas. However, the number of false-positives is increasing, together with the addition of intracanalicular tumors visualized by air CTC. In this study, we examined the value of intracanalicular enhancement (IE) in the differential diagnosis between ''ear tumor'' and its false-positive. Eight cases (4 negative, 3 positive, and 1 false-positive) were analysed retrospectively. All but the four negative cases has been histologically verified on surgery. IE was judged to be positive when some diffuse enhancement was observed in the middle of the enlarged canal on serial thin-section scans under the display setting (window level and width) similar to the brain. Three intracanalicular tumors showed an apparent enhancement, while the three non-tumor cases and one false-positive case showed no enhancement. IE was inconclusive in the one remaining case without a tumor, possibly because of the narrow canal (5 mm). On the basis of these investigations, even though the number of cases has been limited, we can say that IE seems a very promising way to exclude false-positives in the diagnosis of intracanalicular tumors by air CTC. (author)

  9. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  10. Chest CT study of patients with asbestos exposure, 1

    International Nuclear Information System (INIS)

    Hatakeyama, Masayuki

    1988-01-01

    Thin-slice high-resolution computed tomographic (CT) findings of 36 patients (34 men, 2 women) with histories of long-term (11 to 43 years) occupational asbestos exposure (AS) were analyzed for pulmonary abnormalities, which were classified by the subpleural curvilinear shadow (SCLS) and/or the extent of honeycomb shadow (HS) into five types (O to IV). SCLS was detected in 22 patients (62 %), and HS in 14 patients (39 %). SCLS was distributed mainly in the lower lobe in patients with mild pulmonary fibrosis (Types I and II) and in segments where fibrosis was mild in patients with HS (Types III and IV). This may reflect the initiation of pulmonary fibrosis leading to the formation of a HS. Most (63.7 %) SCLS measured > 5 cm but < 10 cm in length and occurred < 1 cm from the inner chest wall in all cases. Radiologic-pathologic correlation of SCLS and HS in CT imagings, achieved in two post mortem specimens, seemed to indicate that SCLS was associated with the initial change of fibrosing bronchiolo-alveolitis, which is characteristic of pulmonary asbestosis. Thin-slice high-resolution CT findings of 36 patients with AS and 33 patients with idiopathic interstitial pneumonia (IIP) were compared. Though the incidence of SCLS was low (21 %) in this series of IIP, its presence suggests that SCLS is not specific to pulmonary asbestosis but occurs also in chronic interstitial pneumonia. In order to explore the mechanism of the appearance of SCLS, further analysis of CT and histopathologic findings not only of pulmonary asbestosis and IIP but also of many other pulmonary interstitial diseases is necessary. It could be considered that thin-slice high-resolution CT which first detected SCLS is very useful in the visualization of fine structures of the lungs. (author)

  11. Interstitial lung disease in anti-synthetase syndrome: Initial and follow-up CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Debray, Marie-Pierre, E-mail: marie-pierre.debray@bch.aphp.fr [AP-HP, Bichat-Claude Bernard Hospital, Department of Radiology, 46, rue Henri Huchard, 75877 Paris Cedex 18 (France); Borie, Raphael, E-mail: raphael.borie@bch.aphp.fr [AP-HP, Bichat-Claude Bernard Hospital, Department of Pneumology A and Centre de Compétence Maladies Pulmonaires rares, DHU Fire 46, rue Henri Huchard, 75877 Paris Cedex 18 (France); Inserm, U1152, Paris (France); Revel, Marie-Pierre, E-mail: marie-pierre.revel@htd.aphp.fr [AP-HP, Cochin Hospital, Department of Radiology, 27, Rue du Fg Saint Jacques, 75679 Paris Cedex 14 (France); Naccache, Jean-Marc, E-mail: jean-marc.naccache@tnn.aphp.fr [AP-HP, Avicenne Hospital, Department of Pneumology and Centre de Compétence Maladies Pulmonaires rares, Bobigny (France); AP-HP, Tenon Hospital, Department of Pneumology and Centre de Compétence Maladies Pulmonaires rares, 4, rue de la Chine, 75020 Paris (France); Khalil, Antoine, E-mail: antoine.khalil@tnn.aphp.fr [AP-HP, Tenon Hospital, Department of Radiology, 4, rue de la Chine, 75020 Paris (France); Toper, Cécile, E-mail: cecile.toper@gmail.com [AP-HP, Tenon Hospital, Department of Pneumology and Centre de Compétence Maladies Pulmonaires rares, 4, rue de la Chine, 75020 Paris (France); Israel-Biet, Dominique, E-mail: dominique.israel-biet@egp.aphp.fr [Université Paris Descartes and AP-HP, Department of Pneumology, Georges Pompidou European Hospital, 20, rue Leblanc, 75015 Paris (France); and others

    2015-03-15

    Purpose: To describe the initial and follow-up CT features of interstitial lung disease associated with anti-synthetase syndrome (AS-ILD). Materials and methods: Two independent thoracic radiologists retrospectively analysed thin-section CT images obtained at diagnosis of AS-ILD in 33 patients (17 positive for anti-Jo1, 13 for anti-PL12, and three for anti-PL7 antibodies). They evaluated the pattern, distribution and extent of the CT abnormalities. They also evaluated the change in findings during follow-up (median 27 months; range 13–167 months) in 26 patients. Results: At diagnosis, ground-glass opacities (100%), reticulations (87%) and traction bronchiectasis (76%) were the most common CT findings. Consolidations were present in 45% of patients. A non-specific interstitial pneumonia (NSIP), organizing pneumonia (OP) or mixed NSIP-OP CT pattern were observed in 15 out of 33 (45%), seven out of 33 (21%) and eight out of 33 (24%) patients, respectively, whereas the CT pattern was indeterminate in three patients. During follow-up, consolidations decreased or disappeared in 11 out of 12 patients (92%), among which seven within the first 6 months, but honeycombing progressed or appeared in ten out of 26 patients (38%) and overall disease extent increased in nine out of 26 patients (35%). Conclusion: CT features at diagnosis of AS-ILD mainly suggest NSIP and OP, isolated or in combination. Consolidations decrease or disappear in most cases but the disease may progress to fibrosis in more than one third of patients.

  12. Helical CT imaging of clinically suspected appendicitis: Correlation of CT and histological findings

    International Nuclear Information System (INIS)

    Wong, S.K.; Chan, L.P.; Yeo, A.

    2002-01-01

    PURPOSE: The diagnosis of appendicitis is traditionally made on the basis of clinical findings supported by laboratory results. The aim of our study was to determine the accuracy and feasibility of using a relatively new technique of computed tomography (CT) using only colonic contrast medium. MATERIALS AND METHODS: A total of 50 patients clinically diagnosed as having appendicitis were prospectively examined before surgery with thin-collimation helical CT from the L3 level to the acetabular roof with only rectally administered colon contrast medium. The hard copy CT images were reviewed jointly by two radiologists and a consensus was reached for each patient. The results were then compared with the surgical and histological findings at appendicectomy. RESULTS: There were 35 true-positives, one false-positive, 12 true-negatives and two false-negatives for CT. This yielded an accuracy of 94%, sensitivity of 95%, specificity of 92%, positive predictive value of 97% and negative predictive value of 86%. The appendix was identified in 45 patients (90%) and obscured by an inflammatory mass in the remaining five. An alternative diagnosis was found in 10 of 12 normal CT examinations (83%). CONCLUSION: Helical CT with rectal contrast medium is a quick, well tolerated and accurate test to diagnose appendicitis. It can offer alternative, possibly non-surgical diagnosis in patients who would otherwise have undergone laparotomy. Wong, S.K. et al. (2002)

  13. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  14. Effect of cluster thinning and prohexadione calcium applications on phenolic composition and sensory properties of red wines.

    Science.gov (United States)

    Avizcuri-Inac, José-Miguel; Gonzalo-Diago, Ana; Sanz-Asensio, Jesús; Martínez-Soria, María-Teresa; López-Alonso, Miguel; Dizy-Soto, Marta; Echávarri-Granado, José-Federico; Vaquero-Fernández, Luis; Fernández-Zurbano, Purificación

    2013-02-06

    The overall objective of this study was to investigate the effect of manual cluster thinning (CT) and the application of the growth regulator Prohexadione calcium (ProCa) on the phenolic composition and the sensory profile of Tempranillo and Grenache wines produced from treated vines in La Rioja (Spain). ProCa was applied at preblooming and CT was carried out at veraison in two consecutive years. Different physicochemical parameters and analyses of phenolic compounds were carried out in control, CT and ProCa grapes and wines and wine sensory was performed. Thinning treatments decreased crop yield, besides ProCa application reduced berry size, and berry weight. Color and phenolic composition of Grenache and Tempranillo wines in general were affected by thinning treatments, with an increase in anthocyanin, flavanol and flavonol concentrations. In sensory analysis, wines obtained from thinned vines presented higher values for several aromatic (e.g., white and yellow fruits, fresh flowers) and taste attributes (i.e., astringency, bitternes, persistence). CT and ProCa treatments resulted in an improvement in wine quality. In general, similar results in phenolic composition, sensory properties and quality of wines were obtained by manual and chemical cluster thinning. ProCa as a growth regulator may be an option for a quality vitiviniculture.

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... multislice CT" or "multidetector CT," allow thinner slices to be obtained, resulting in more detail of the body, in a shorter period of time. Modern CT scanners are so fast that they can scan through large sections of the body in just a few seconds. Such speed is beneficial for ...

  16. X-ray and CT findings of costal eosinophilic granuloma

    International Nuclear Information System (INIS)

    Tu Zhanhai; Lin Zhengyu; Chen Yiguang

    2010-01-01

    Objective: To study the X-ray and CT features of costal eosinophilic granuloma for a better understanding. Methods: Eight patients with costal eosinophilic granuloma proved by surgery or biopsy were analyzed retrospectively. All patients had X-ray plain film, 6 patients had CT examination, including a case of enhanced CT scan. Results: All 8 lesions were solitary. Six lesions were in the anterior rib and 2 in the posterior rib. On X-ray, all case showed single cavity and oval lesion with clear boundary. On CT images, 5 lesions demonstrated expansile destruction of bone with cortical bone thinning, and 3 were osteolystic destruction with soft tissue mass around. On the patient with enhanced CT scan, the lesions showed a moderate and uniform enhancement. Conclusion: The X-ray and CT findings of costal eosinophilic granuloma are characteristic. (authors)

  17. CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings

    International Nuclear Information System (INIS)

    Kramer, E.L.; Noz, M.E.; Sanger, J.J.; Megibow, A.J.; Maguire, G.Q.

    1989-01-01

    To enhance the information provided by computed tomography (CT) and single photon emission computed tomography (SPECT) performed with radiolabeled, anti-carcinoembryonic antigen monoclonal antibody (MoAb), the authors performed fusion of these types of images from eight subjects with suspected colorectal adenocarcinoma. Section thickness and pixel size of the two studies were matched, coordinates of corresponding points from each study were identified, and CT sections were translated, rotated, and reprojected to match the corresponding SPECT scans. The CT-SPECT fusion enabled identification of anatomic sites of tumor-specific MoAb accumulation in four cases, showed non-specific MoAb accumulation in two, and helped confirm information only suggested by the two studies separately in one

  18. Nanoscale size effects on the mechanical properties of platinum thin films and cross-sectional grain morphology

    KAUST Repository

    Abbas, K

    2015-12-10

    © 2016 IOP Publishing Ltd. The mechanical behavior of polycrystalline Pt thin films is reported for thicknesses of 75 nm, 100 nm, 250 nm, and 400 nm. These thicknesses correspond to transitions between nanocrystalline grain morphology types as found in TEM studies. Thinner samples display a brittle behavior, but as thickness increases the grain morphology evolves, leading to a ductile behavior. During evolution of the morphology, dramatic differences in elastic moduli (105-160 GPa) and strengths (560-1700 MPa) are recorded and explained by the variable morphology. This work suggests that in addition to the in-plane grain size of thin films, the transitions in cross-sectional morphologies of the Pt films significantly affect their mechanical behavior.

  19. Deep learning of the sectional appearances of 3D CT images for anatomical structure segmentation based on an FCN voting method.

    Science.gov (United States)

    Zhou, Xiangrong; Takayama, Ryosuke; Wang, Song; Hara, Takeshi; Fujita, Hiroshi

    2017-10-01

    issue of anatomical structure segmentation in 3D CT cases. The novelty of this work is the policy of deep learning of the different 2D sectional appearances of 3D anatomical structures for CT cases and the majority voting of the 3D segmentation results from multiple crossed 2D sections to achieve availability and reliability with better efficiency, generality, and flexibility than conventional segmentation methods, which must be guided by human expertise. © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  20. Surface oxidation on thin films affects ionization cross section induced by proton beam

    International Nuclear Information System (INIS)

    Bertol, Ana Paula Lamberti; Vasconcellos, M.A.Z.; Hinrichs, Ruth; Limandri, Silvina; Trincavelli, Jorge

    2012-01-01

    Full text: In microanalysis techniques such as Particle Induced X-ray Emission (PIXE), the transformation from intensity to concentration is made by standard less software that needs exact values of fundamental parameters such as the ionization cross section, transition probabilities of the different electronic levels, and fluorescent yield. The three parameters together measure the photon generating probability of an electronic transition and can be determined experimentally under the name of production cross section. These measurements are performed on thin films, with thickness around 10 nm, but most studies do not take into account any spontaneous surface oxidation. In this work, in the attempt to obtain cross section values of Al, Si and Ti, in metallic and oxide films, the influence of surface oxidation on the metallic films was established. Simulations considering the oxidation with the software SIMNRA on the Rutherford backscattering (RBS) spectra obtained from the films provided mass thickness values used to calculate the cross section data that were compared with theoretical values (PWBA and ECPSSR), and with experimental values and empirical adjustments from other studies. The inclusion of the natural oxidation affects the values of cross section, and may be one of the causes of discrepancies between the experimental values published in literature. (author)

  1. Shape and dimensions of cardiac chambers: Importance of CT section thickness and orientation

    International Nuclear Information System (INIS)

    Hoffman, E.A.; Ritman, E.L.

    1985-01-01

    Three-dimensional (3D) computed tomography (CT) scan data were used to quantitate the geometry of all heart chambers. The Dynamic Spatial Reconstructor (DSR) was used to scan dogs with in situ casts of the cardiac chambers. Chamber volumes estimated from DSR images were accurate within 5% of water displacement volume measurements of the actual casts for chambers greater than 11 ml and within 10% of water displacement volumes for chambers less than 11 ml. Anatomic features of the actual cast correlated closely with anatomy visible in computer-generated surface images of the 3D DSR image data. The important effect of reconstructed section thickness and orientation on the fidelity of 3D cardiac geometry is demonstrated

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT ... be performed to evaluate blood vessels throughout the body. With CT, it is possible to obtain very ...

  3. Individualized volume CT dose index determined by cross-sectional area and mean density of the body to achieve uniform image noise of contrast-enhanced pediatric chest CT obtained at variable kV levels and with combined tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    A practical body-size adaptive protocol providing uniform image noise at various kV levels is not available for pediatric CT. To develop a practical contrast-enhanced pediatric chest CT protocol providing uniform image noise by using an individualized volume CT dose index (CTDIvol) determined by the cross-sectional area and density of the body at variable kV levels and with combined tube current modulation. A total of 137 patients (mean age, 7.6 years) underwent contrast-enhanced pediatric chest CT based on body weight. From the CTDIvol, image noise, and area and mean density of the cross-section at the lung base in the weight-based group, the best fit equation was estimated with a very high correlation coefficient ({gamma}{sup 2} = 0.86, P < 0.001). For the next study, 177 patients (mean age, 7.9 years; the CTDIvol group) underwent contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the best fit equation. CTDIvol values on the dose report after CT scanning, noise differences from the target noise, areas, and mean densities were compared between these two groups. The CTDIvol values (mean{+-}standard deviation, 1.6 {+-} 0.7 mGy) and the noise differences from the target noise (1.1 {+-} 0.9 HU) of the CTDIvol group were significantly lower than those of the weight-based group (2.0 {+-} 1.0 mGy, 1.8 {+-} 1.4 HU) (P < 0.001). In contrast, no statistically significant difference was found in area (317.0 {+-} 136.8 cm{sup 2} vs. 326.3 {+-} 124.8 cm{sup 2}), mean density (-212.9 {+-} 53.1 HU vs. -221.1 {+-} 56.3 HU), and image noise (13.8 {+-} 2.3 vs. 13.6 {+-} 1.7 HU) between the weight-based and the CTDIvol groups (P > 0.05). Contrast-enhanced pediatric chest CT with the CTDIvol determined individually by the cross-sectional area and density of the body provides more uniform noise and better dose adaptation to body habitus than does weight-based CT at variable kV levels and with combined tube current modulation. (orig.)

  4. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    International Nuclear Information System (INIS)

    Takenaka, Daisuke; Ohno, Yoshiharu; Koyama, Hisanobu; Nogami, Munenobu; Onishi, Yumiko; Matsumoto, Keiko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2010-01-01

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV 1 ) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 ≤ r ≤ -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  5. Co-registered perfusion SPECT/CT: Utility for prediction of improved postoperative outcome in lung volume reduction surgery candidates

    Energy Technology Data Exchange (ETDEWEB)

    Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.j [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Koyama, Hisanobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, 2-2, Minatojima Minamimachi Chuo-ku, Kobe, Hyogo, 650-0047 (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Matsumoto, Keiko [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan); Department of Radiology, University of Yamanashi, 1110 Shimogato, Chuo, Yamanashi, 409-3898 (Japan); Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017 (Japan)

    2010-06-15

    Purpose: To directly compare the capabilities of perfusion scan, SPECT, co-registered SPECT/CT, and quantitatively and qualitatively assessed MDCT (i.e. quantitative CT and qualitative CT) for predicting postoperative clinical outcome for lung volume reduction surgery (LVRS) candidates. Materials and methods: Twenty-five consecutive candidates (19 men and six women, age range: 42-72 years) for LVRS underwent preoperative CT and perfusion scan with SPECT. Clinical outcome of LVRS for all subjects was also assessed by determining the difference between pre- and postoperative forced expiratory volume in 1 s (FEV{sub 1}) and 6-min walking distance (6MWD). All SPECT examinations were performed on a SPECT scanner, and co-registered to thin-section CT by using commercially available software. On planar imaging, SPECT and SPECT/CT, upper versus lower zone or lobe ratios (U/Ls) were calculated from regional uptakes between upper and lower lung fields in the operated lung. On quantitatively assessed CT, U/L for all subjects was assessed from regional functional lung volumes. On qualitatively assessed CT, planar imaging, SPECT and co-registered SPECT/CT, U/Ls were assessed with a 4-point visual scoring system. To compare capabilities of predicting clinical outcome, each U/L was statistically correlated with the corresponding clinical outcome. Results: Significantly fair or moderate correlations were observed between quantitatively and qualitatively assessed U/Ls obtained with all four methods and clinical outcomes (-0.60 {<=} r {<=} -0.42, p < 0.05). Conclusion: Co-registered perfusion SPECT/CT has better correlation with clinical outcome in LVRS candidates than do planar imaging, SPECT or qualitatively assessed CT, and is at least as valid as quantitatively assessed CT.

  6. CT findings of fundal hemorrhage in subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Munemoto, Shigeru; Ishiguro, Shuzo; Kimura, Akira; Futami, Kazuya; Kogure, Yuzaburo; Wakamatsu, Koichi; Demachi, Hiroshi

    1987-01-01

    The patient was a 66-year-old man. He lost consciousness as a result of a third subarachnoid hemorrhage attack. On neurological examination, he was found to be comatose and to have no spontaneous respiration. A mydriasis was noticed on both eyes. Bilateral retinal bleeding was also observed, with the bleeding of the left side more severe than that of the right side. After his death, his brain and eyes were examined by means of a CT scan. The CT films showed a severe subarachnoid hemorrhage and ventricular hematoma. The thin-sliced CT films showed left retinal bleeding. Retinal bleeding may be caused by a subarachnoid hemorrhage. Usually we make a sketch of the retinal bleeding on the basis of a doctor's report. A photo of an optic fundus is a good record; however, taking a photo is troublesome for severely ill patients. The CT finding of retinal bleeding is gross, but a CT image is one good way to record retinal bleeding. (author)

  7. The thin section rock physics: Modeling and measurement of seismic wave velocity on the slice of carbonates

    Energy Technology Data Exchange (ETDEWEB)

    Wardaya, P. D., E-mail: pongga.wardaya@utp.edu.my; Noh, K. A. B. M., E-mail: pongga.wardaya@utp.edu.my; Yusoff, W. I. B. W., E-mail: pongga.wardaya@utp.edu.my [Petroleum Geosciences Department, Universiti Teknologi PETRONAS, Tronoh, Perak, 31750 (Malaysia); Ridha, S. [Petroleum Engineering Department, Universiti Teknologi PETRONAS, Tronoh, Perak, 31750 (Malaysia); Nurhandoko, B. E. B. [Wave Inversion and Subsurface Fluid Imaging Research Laboratory (WISFIR), Dept. of Physics, Institute of Technology Bandung, Bandung, Indonesia and Rock Fluid Imaging Lab, Bandung (Indonesia)

    2014-09-25

    This paper discusses a new approach for investigating the seismic wave velocity of rock, specifically carbonates, as affected by their pore structures. While the conventional routine of seismic velocity measurement highly depends on the extensive laboratory experiment, the proposed approach utilizes the digital rock physics view which lies on the numerical experiment. Thus, instead of using core sample, we use the thin section image of carbonate rock to measure the effective seismic wave velocity when travelling on it. In the numerical experiment, thin section images act as the medium on which wave propagation will be simulated. For the modeling, an advanced technique based on artificial neural network was employed for building the velocity and density profile, replacing image's RGB pixel value with the seismic velocity and density of each rock constituent. Then, ultrasonic wave was simulated to propagate in the thin section image by using finite difference time domain method, based on assumption of an acoustic-isotropic medium. Effective velocities were drawn from the recorded signal and being compared to the velocity modeling from Wyllie time average model and Kuster-Toksoz rock physics model. To perform the modeling, image analysis routines were undertaken for quantifying the pore aspect ratio that is assumed to represent the rocks pore structure. In addition, porosity and mineral fraction required for velocity modeling were also quantified by using integrated neural network and image analysis technique. It was found that the Kuster-Toksoz gives the closer prediction to the measured velocity as compared to the Wyllie time average model. We also conclude that Wyllie time average that does not incorporate the pore structure parameter deviates significantly for samples having more than 40% porosity. Utilizing this approach we found a good agreement between numerical experiment and theoretically derived rock physics model for estimating the effective seismic

  8. The thin section rock physics: Modeling and measurement of seismic wave velocity on the slice of carbonates

    International Nuclear Information System (INIS)

    Wardaya, P. D.; Noh, K. A. B. M.; Yusoff, W. I. B. W.; Ridha, S.; Nurhandoko, B. E. B.

    2014-01-01

    This paper discusses a new approach for investigating the seismic wave velocity of rock, specifically carbonates, as affected by their pore structures. While the conventional routine of seismic velocity measurement highly depends on the extensive laboratory experiment, the proposed approach utilizes the digital rock physics view which lies on the numerical experiment. Thus, instead of using core sample, we use the thin section image of carbonate rock to measure the effective seismic wave velocity when travelling on it. In the numerical experiment, thin section images act as the medium on which wave propagation will be simulated. For the modeling, an advanced technique based on artificial neural network was employed for building the velocity and density profile, replacing image's RGB pixel value with the seismic velocity and density of each rock constituent. Then, ultrasonic wave was simulated to propagate in the thin section image by using finite difference time domain method, based on assumption of an acoustic-isotropic medium. Effective velocities were drawn from the recorded signal and being compared to the velocity modeling from Wyllie time average model and Kuster-Toksoz rock physics model. To perform the modeling, image analysis routines were undertaken for quantifying the pore aspect ratio that is assumed to represent the rocks pore structure. In addition, porosity and mineral fraction required for velocity modeling were also quantified by using integrated neural network and image analysis technique. It was found that the Kuster-Toksoz gives the closer prediction to the measured velocity as compared to the Wyllie time average model. We also conclude that Wyllie time average that does not incorporate the pore structure parameter deviates significantly for samples having more than 40% porosity. Utilizing this approach we found a good agreement between numerical experiment and theoretically derived rock physics model for estimating the effective seismic wave

  9. Primary thyroid lymphoma: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo-Cheol; Han, Moon Hee E-mail: hanmh@radcom.snu.ac.kr; Kim, Keon Ha; Jae, Hwan Jun; Lee, Sang Hyun; Kim, Sam Soo; Kim, Kwang Hyun; Chang, Kee-Hyun

    2003-06-01

    Introduction: To evaluate the computed tomographic (CT) findings of primary thyroid lymphoma. Methods and material: The clinicopathological data and CT images of nine patients with primary thyroid lymphoma were retrospectively reviewed. The CT appearances were classified into three types: type 1, a solitary nodule surrounded by normal thyroid tissue; type 2, multiple nodules in the thyroid, and type 3, a homogeneously enlarged both thyroid glands with a reduced attenuation with or without peripheral thin hyperattenuating thyroid tissue. Results: All patients had a rapidly enlarging thyroid mass and coexistent Hashimoto's thyroiditis. One patient showed type 1 pattern, three type 2, and five type 3. Six patients had homogeneous tumor isoattenuating to surrounding muscles. The tumors had a strong tendency to compress normal remnant thyroid and the surrounding structure without invasion. Conclusion: Primary thyroid lymphoma should be included in the differential diagnosis when old female had a homogeneous thyroidal mass isoattenuating to muscles, which does not invade surrounding structures.

  10. Computed tomography and sectional anatomy of the head cavities in donkey (Equus asinus).

    Science.gov (United States)

    El-Gendy, S A A; Alsafy, M A M; El Sharaby, A A

    2014-06-01

    The purpose of this study was to describe the computed tomographic (CT) anatomy of normal donkey head cavities to be used as a basis for interpretation of CT images of donkey. Six adult donkeys' heads of undetermined sex were used in this study. The donkey heads were divided into three regions-nasal, orbital, and cranial-to show the morphology of the following cavities: nasal cavity, paranasal sinuses, orbital cavity, oral cavity, pharyngeal cavity, especially the guttural pouch, cranial cavity and temporomandibular joint. The donkey head had six pairs of sinuses: three paranasal (the frontal, maxillary and sphenopalatine sinuses) and three nasal (dorsal, middle and ventral conchal) sinuses. The maxillary sinus was subdivided into rostral and caudal compartments by a thin incomplete bony septum that was identified and labeled according to cheek teeth landmarks. The topographic description and relationship between the nasal, oral, orbital, cranial, temporomandibular joint, pharyngeal cavities and paranasal sinuses were demonstrated. The articular disc, articular surface and joint capsule of the temporomandibular joint were indicated easily in our CT and cross sectional images.

  11. Comparison of PET/CT and whole-mount histopathology sections of the human prostate: a new strategy for voxel-wise evaluation.

    Science.gov (United States)

    Schiller, F; Fechter, T; Zamboglou, C; Chirindel, A; Salman, N; Jilg, C A; Drendel, V; Werner, M; Meyer, P T; Grosu, A-L; Mix, M

    2017-08-17

    Implementation of PET/CT in diagnosis of primary prostate cancer (PCa) requires a profound knowledge about the tracer, preferably from a quantitative evaluation. Direct visual comparison of PET/CT slices to whole prostate sections is hampered by considerable uncertainties from imperfect coregistration and fundamentally different image modalities. In the current study, we present a novel method for advanced voxel-wise comparison of histopathology from excised prostates to pre-surgical PET. Resected prostates from eight patients who underwent PSMA-PET/CT were scanned (ex vivo CT) and thoroughly pathologically prepared. In vivo and ex vivo CT including histopathology were coregistered with three different methods (manual, semi-/automatic). Spatial overlap after CT-based registration was evaluated with dice similarity (DSC). Furthermore, we constructed 3D cancer distribution models from histopathologic information in various slices. Subsequent smoothing reflected the intrinsically limited spatial resolution of PSMA-PET. The resulting histoPET models were used for quantitative analysis of spatial histopathology-PET pattern agreement focusing on p values and coefficients of determination (R 2 ). We examined additional rigid mutual information (MI) coregistration directly based on PSMA-PET and histoPET. Mean DSC for the three different methods (ManReg, ScalFactReg, and DefReg) were 0.79 ± 0.06, 0.82 ± 0.04, and 0.90 ± 0.02, respectively, while quantification of PET-histopathology pattern agreement after CT-based registration revealed R 2 45.7, 43.2, and 41.3% on average with p PET-based MI coregistration yielded R 2 61.3, 55.9, and 55.6%, respectively, while implying anatomically plausible transformations. Creating 3D histoPET models based on thorough histopathological preparation allowed sophisticated quantitative analyses showing highly significant correlations between histopathology and (PSMA-)PET. We recommend manual CT-based coregistration followed by a PET

  12. Spinal CT scan, 2. Lumbar and sacral spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ., Aichi (Japan))

    1982-08-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival.

  13. CT manifestations of peritoneal carcinomatosis.

    Science.gov (United States)

    Walkey, M M; Friedman, A C; Sohotra, P; Radecki, P D

    1988-05-01

    Seventy-three abdominopelvic contrast-enhanced CT scans obtained in 60 patients with peritoneal tumor spread were reviewed retrospectively to determine the CT signs of peritoneal malignancy. Ascites was present in 54 studies (74%) and was the most common CT finding. Loculation of the fluid occurred in 25 (46%) of these. In nine (17%) of the 54, a new finding, absence of cul-de-sac fluid in the presence of generalized ascites, was noted. Parietal peritoneal thickening with contrast enhancement of the peritoneum, making the peritoneum visible as a thin line along the abdominal wall, was present in 45 (62%) of studies. This is believed to represent confluent peritoneal metastases. Small-bowel involvement was present in half of the cases (wall thickening and irregularity with or without obstruction). Tumor involvement of the omentum was visible as soft-tissue permeation of fat, enhancing nodules, and/or an omental cake. Of the 26 patients without a previously known malignancy, identification of the primary tumor in addition to peritoneal carcinomatosis was possible in 13 (50%). Appreciation of the spectrum of CT findings in peritoneal carcinomatosis is essential for accurate evaluation of scans in patients with abdominopelvic malignancies.

  14. A Novel Hybrid Ultramicrotomy/FIB-SEM Technique: Preparation of Serial Electron-Transparent Thin Sections of a Hayabusa Grain

    Science.gov (United States)

    Berger, Eve L.; Keller, Lindsay P.

    2014-01-01

    The Japanese space agency's (JAXA) Hayabusa mission returned the first particulate samples (typically grain surfaces and interiors. Using this method, we increase the number of FIB-prepared sections that can be recovered from a particle with dimensions on the order of tens of microns. These sections can be subsequently analyzed using a variety of analytical techniques. Particle RA-QD02-0211 is a approx. 40×40×20 micron particle from Itokawa containing olivine and Fe sulfides. It was embedded in low viscosity epoxy and partly sectioned to a depth of approx 10 micron; sections are placed on Cu grids with thin amorphous films for transmission electron microscope (TEM) analyses. With the sample surface partly exposed, the epoxy bullet is trimmed to a height of approx. 5mm to accommodate the allowable dimensions for FIB work (FEI Quanta 600 3D dual beam FIB-SEM). Using a diamond trim knife, the epoxy surrounding the grain is removed on 3 sides (to within a few microns of the grain); the depth of material removed extends well below the bottom of the particle. The sample is attached to an SEM pin mount, the epoxy coated with conductive paint, and the entire assembly coated with approx. 40nm of carbon to eliminate sample charging during FIB work. A protective carbon cap is placed according to the plan for the 15 FIB sections. The central 'spine' of the cap runs perpendicular to the front of the sample, and the 'ribs' protruding from either side run parallel. Each rib indicates the location of a planned FIB section, and the spine contains the final two planned sections. We use a cap with a 4 micron-wide spine and 2micron-wide ribs that have ?3.5 micron of space between them (narrower cuts result in too much re-deposition of material inside the trenches). Using a 30kV, 3nA ion-beam we expose the front surface of the grain and commence milling trenches between sections. Rather than using the typical C-cut to prepare the sample for lift-out, an L-cut is used instead, leaving

  15. Influence of gating design on microstructure and fluidity of thin sections AA320.0 cast hypo-eutectic Al-Si alloy

    Science.gov (United States)

    Ramadan, Mohamed

    2018-05-01

    Influence of gating design especially number of ingrates on microstructure and fluidity of thin sections of 2, 4, 6 mm AA320.0 cast hypo-eutectic Al-Si alloy was evaluated for sand casting molding technique. Increasing the number of ingates improves the microstructe to be fine and more globular. About 87 μm of α-Al grain size, 0.6 α-Al grain sphericity and 37 μm dendrite arm spacing DAS are achieved by using 4 ingates in gating system. Increasing the number of ingates up to 3 increases hardness, filling area and related fluditiy of all cast samples. The minimum thickness of 2.5 mm for each ingate should be considered in order to successfully production of high quality light weight thin sections castings in sand mold.

  16. CT-diagnosis of temporal bone trauma

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Stuckmann, G.; Antonucci, F.; Schubiger, O.

    1986-02-01

    73 patients with 78 fractures of the temporal bone were examined by high-resolution computed tomography (CT). Analysis of the CT-findings disclosed 55 longitudinal, 12 transverse, 8 combined and 3 atypical fractures. For determination of the fracture type, axial sections usually proved sufficient. However, for precise topographic analysis of the course of the fracture additional coronal sections were necessary in most of the cases. In the radiologic evaluation of temporal bone fractures detection of associated. Complications is clinically important since these can be surgically corrected. In this series 20 lesions of the ossicular chain were demonstrated by the combined performance of axial and coronal sections and sagittal reformations. High resolution CT demonstrated a lesion of the facial nerve canal in 79% of a patient group with traumatic facial nerve palsy. The most frequent site of injury of the facial nerve canal was the region of the geniculate ganglion. With the use of metrizaminde-CT-cisternography the site of cerebrospinal fluid leakage was demonstrated in 7 of 9 patients with liquorrhea. It is concluded that high-resolution CT is the radiologic method of choice for both topographic evaluation of temporal bone fractures and detection and precise localization of fracture-complications. (orig.).

  17. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  18. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  19. NUMERICAL ANALYSIS OF THE CRITICAL STATE OF THIN-WALLED STRUCTURE WITH Z-PROFILE CROSS SECTION

    Directory of Open Access Journals (Sweden)

    Patryk Różyło

    2017-03-01

    Full Text Available The object of the study was the thin-walled profile with Z-shaped cross section made of the carbon-epoxy composite. Material model was prepared based on the implemented orthotropic properties. The purpose of study was to determine the value of the critical load at which buckling occurs, the form of buckling and operating characteristics in critical condition. In order to achieve this numerical analysis were carried out. Additionally, the effects of the modification in arrangement of layers of the laminate to the stability and strength of thin-walled composite structures was presented. Numerical studies were carried out using commercial simulation software - ABAQUS®. Within the FEM research, both forms of buckling and the associated critical load, dependent on the configuration the layers of the composite were achieved. Analysis of the obtained results, allowed the evaluation of the structure's work in relation to the level of energy consumption or rigidity estimation. In the paper only numerical simulations of the critical state were conducted.

  20. Pulmonary light-chain deposition disease: CT and pathology findings in nine patients

    International Nuclear Information System (INIS)

    Sheard, S.; Nicholson, A.G.; Edmunds, L.; Wotherspoon, A.C.; Hansell, D.M.

    2015-01-01

    Aim: To review the clinical features of nine patients with pulmonary light-chain deposition disease (LCDD) and record their high-resolution CT (HRCT) and histopathological findings. Materials and methods: Patients with a diagnosis of LCDD on lung biopsy specimen were retrospectively identified. The HRCT characteristics of nodules, cysts, and ancillary findings; change at follow-up; and histopathological findings were documented. Results: Features common to all nine cases were thin-walled cysts. In seven cases, vessels traversing the cysts were identified. The majority of patients (8/9) had at least one pulmonary nodule. There was no zonal predominance of either cysts or nodules. The disease appeared stable in the majority of cases with no serial change in HRCT appearances (5/6 cases with follow-up data, mean duration 29 months). Conclusion: To the authors' knowledge, this is the largest series of pulmonary LCDD patients in the literature, and the first systematic assessment of HRCT findings. Pulmonary cysts are a unifying feature, usually with pulmonary nodules, and serial change on HRCT is unusual. - Highlights: • Nine cases of pulmonary light chain deposition disease with high-resolution CT. • CT scans assessed for abnormal features. • Clinical data and histopathological findings obtained. • All patients had thin-walled cysts on CT, often with traversing vessels. • CT features of disease in this group are cysts, nodules and an indolent course

  1. Differential production cross sections for charged particles produced by 590 MeV proton bombardment of thin metal targets

    International Nuclear Information System (INIS)

    Howe, S.D.; Cierjacks, S.; Hino, Y.; Raupp, F.; Rainbow, M.T.; Swinhoe, M.T.; Buth, L.

    1981-01-01

    Differential production cross sections have been measured for the reactions (p,p), (p,d), (p,t) and (p,π+-) using the 590 MeV proton beam at SIN. Here we report measurements made on thin targets of aluminium, niobium, lead, and uranium at laboratory angles of 90 0 and 157 0 . The data were taken over a proton energy range of about 50 MeV to 590 MeV. Differential cross sections are reported along with predictions by the intranuclear-cascade/evaporation model as computed by HETC. (orig.)

  2. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  3. Assessment of consistency of the whole tumor and single section perfusion imaging with 256-slice spiral CT: a preliminary study

    International Nuclear Information System (INIS)

    Sun Hongliang; Xu Yanyan; Hu Yingying; Tian Yuanjiang; Wang Wu

    2014-01-01

    Objective: To determine the consistency between quantitative CT perfusion measurements of colorectal cancer obtained from single section with maximal tumor dimension and from average of whole tumor, and compare intra- and inter-observer consistency of the two analysis methods. Methods: Twenty-two patients with histologically proven colorectal cancer were examined prospectively with 256-slice CT and the whole tumor perfusion images were obtained. Perfusion parameters were obtained from region of interest (ROI) inserted in single section showing maximal tumor dimension, then from ROI inserted in all tumor-containing sections by two radiologists. Consistency between values of blood flow (BF), blood volume (BV) and time to peak (TTP) calculated by two methods was assessed. Intra-observer consistency was evaluated by comparing repeated measurements done by the same radiologist using both methods after 3 months. Perfusion measurements were done by another radiologist independently to assess inter-observer consistency of both methods. The results from different methods were compared using paired t test and Bland-Altman plot. Results: Twenty-two patients were examined successfully. The perfusion parameters BF, BV and TTP obtained by whole tumor perfusion and single-section analysis were (35.59 ± 14.59) ml · min -1 · 100 g -1 , (17.55 ±4.21) ml · 100 g -1 , (21.30 ±7.57) s and (34.64 ± 13.29)ml · min -1 · 100 g -1 , (17.61 ±6.39)ml · 100 g -1 , (19.82 ±9.01) s, respectively. No significant differences were observed between the means of the perfusion parameters (BF, BV, TTP) calculated by the two methods (t=0.218, -0.033, -0.668, P>0.05, respectively). The intra-observer 95% limits of consistency of perfusion parameters were BF -5.3% to 10.0%, BV -13.8% to 10.8%, TTP -15.0% to 12.6% with whole tumor analysis, respectively; BF -14.3% to 16.5%, BV -24.2% to 22.2%, TTP -19.0% to 16.1% with single section analysis, respectively. The inter-observer 95% limits of

  4. Statistical test of reproducibility and operator variance in thin-section modal analysis of textures and phenocrysts in the Topopah Spring member, drill hole USW VH-2, Crater Flat, Nye County, Nevada

    International Nuclear Information System (INIS)

    Moore, L.M.; Byers, F.M. Jr.; Broxton, D.E.

    1989-06-01

    A thin-section operator-variance test was given to the 2 junior authors, petrographers, by the senior author, a statistician, using 16 thin sections cut from core plugs drilled by the US Geological Survey from drill hole USW VH-2 standard (HCQ) drill core. The thin sections are samples of Topopah Spring devitrified rhyolite tuff from four textural zones, in ascending order: (1) lower nonlithophysal, (2) lower lithopysal, (3) middle nonlithophysal, and (4) upper lithophysal. Drill hole USW-VH-2 is near the center of the Crater Flat, about 6 miles WSW of the Yucca Mountain in Exploration Block. The original thin-section labels were opaqued out with removable enamel and renumbered with alpha-numeric labels. The sliders were then given to the petrographer operators for quantitative thin-section modal (point-count) analysis of cryptocrystalline, spherulitic, granophyric, and void textures, as well as phenocryst minerals. Between operator variance was tested by giving the two petrographers the same slide, and within-operator variance was tested by the same operator the same slide to count in a second test set, administered at least three months after the first set. Both operators were unaware that they were receiving the same slide to recount. 14 figs., 6 tabs

  5. Aorta cross-section calculation and 3D visualization from CT or MRT data using VRML

    Science.gov (United States)

    Grabner, Guenther; Modritsch, Robert; Stiegmaier, Wolfgang; Grasser, Simon; Klinger, Thomas

    2005-04-01

    Quantification of vessel diameters of artherosclerotic or congenital stenosis is very important for the diagnosis of vascular diseases. The aorta extraction and cross-section calculation is a software-based application that offers a three-dimensional, platform-independent, colorized visualization of the extracted aorta with augmented reality information of MRT or CT datasets. This project is based on different types of specialized image processing algorithms, dynamical particle filtering and complex mathematical equations. From this three-dimensional model a calculation of minimal cross sections is performed. In user specified distances, the aorta is cut in differently defined directions which are created through vectors with varying length. The extracted aorta and the derived minimal cross-sections are then rendered with the marching cube algorithm and represented together in a three-dimensional virtual reality with a very high degree of immersion. The aim of this study was to develop an imaging software that delivers cardiologists the possibility of (i) furnishing fast vascular diagnosis, (ii) getting precise diameter information, (iii) being able to process exact, local stenosis detection (iv) having permanent data storing and easy access to former datasets, and (v) reliable documentation of results in form of tables and graphical printouts.

  6. Quantitatively assessed CT imaging measures of pulmonary interstitial pneumonia: Effects of reconstruction algorithms on histogram parameters

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Yamazaki, Youichi; Nogami, Munenobu; Kusaka, Akiko; Murase, Kenya; Sugimura, Kazuro

    2010-01-01

    This study aimed the influences of reconstruction algorithm for quantitative assessments in interstitial pneumonia patients. A total of 25 collagen vascular disease patients (nine male patients and 16 female patients; mean age, 57.2 years; age range 32-77 years) underwent thin-section MDCT examinations, and MDCT data were reconstructed with three kinds of reconstruction algorithm (two high-frequencies [A and B] and one standard [C]). In reconstruction algorithm B, the effect of low- and middle-frequency space was suppressed compared with reconstruction algorithm A. As quantitative CT parameters, kurtosis, skewness, and mean lung density (MLD) were acquired from a frequency histogram of the whole lung parenchyma in each reconstruction algorithm. To determine the difference of quantitative CT parameters affected by reconstruction algorithms, these parameters were compared statistically. To determine the relationships with the disease severity, these parameters were correlated with PFTs. In the results, all the histogram parameters values had significant differences each other (p < 0.0001) and those of reconstruction algorithm C were the highest. All MLDs had fair or moderate correlation with all parameters of PFT (-0.64 < r < -0.45, p < 0.05). Though kurtosis and skewness in high-frequency reconstruction algorithm A had significant correlations with all parameters of PFT (-0.61 < r < -0.45, p < 0.05), there were significant correlations only with diffusing capacity of carbon monoxide (DLco) and total lung capacity (TLC) in reconstruction algorithm C and with forced expiratory volume in 1 s (FEV1), DLco and TLC in reconstruction algorithm B. In conclusion, reconstruction algorithm has influence to quantitative assessments on chest thin-section MDCT examination in interstitial pneumonia patients.

  7. Quantitatively assessed CT imaging measures of pulmonary interstitial pneumonia: Effects of reconstruction algorithms on histogram parameters

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Hisanobu [Department of Radiology, Hyogo Kaibara Hospital, 5208-1 Kaibara, Kaibara-cho, Tanba 669-3395 (Japan)], E-mail: hisanobu19760104@yahoo.co.jp; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan)], E-mail: yosirad@kobe-u.ac.jp; Yamazaki, Youichi [Department of Medical Physics and Engineering, Faculty of Health Sciences, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita 565-0871 (Japan)], E-mail: y.yamazk@sahs.med.osaka-u.ac.jp; Nogami, Munenobu [Division of PET, Institute of Biomedical Research and Innovation, 2-2 MInamimachi, Minatojima, Chu0-ku, Kobe 650-0047 (Japan)], E-mail: aznogami@fbri.org; Kusaka, Akiko [Division of Radiology, Kobe University Hospital, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan)], E-mail: a.kusaka@hosp.kobe-u.ac.jp; Murase, Kenya [Department of Medical Physics and Engineering, Faculty of Health Sciences, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita 565-0871 (Japan)], E-mail: murase@sahs.med.osaka-u.ac.jp; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan)], E-mail: sugimura@med.kobe-u.ac.jp

    2010-04-15

    This study aimed the influences of reconstruction algorithm for quantitative assessments in interstitial pneumonia patients. A total of 25 collagen vascular disease patients (nine male patients and 16 female patients; mean age, 57.2 years; age range 32-77 years) underwent thin-section MDCT examinations, and MDCT data were reconstructed with three kinds of reconstruction algorithm (two high-frequencies [A and B] and one standard [C]). In reconstruction algorithm B, the effect of low- and middle-frequency space was suppressed compared with reconstruction algorithm A. As quantitative CT parameters, kurtosis, skewness, and mean lung density (MLD) were acquired from a frequency histogram of the whole lung parenchyma in each reconstruction algorithm. To determine the difference of quantitative CT parameters affected by reconstruction algorithms, these parameters were compared statistically. To determine the relationships with the disease severity, these parameters were correlated with PFTs. In the results, all the histogram parameters values had significant differences each other (p < 0.0001) and those of reconstruction algorithm C were the highest. All MLDs had fair or moderate correlation with all parameters of PFT (-0.64 < r < -0.45, p < 0.05). Though kurtosis and skewness in high-frequency reconstruction algorithm A had significant correlations with all parameters of PFT (-0.61 < r < -0.45, p < 0.05), there were significant correlations only with diffusing capacity of carbon monoxide (DLco) and total lung capacity (TLC) in reconstruction algorithm C and with forced expiratory volume in 1 s (FEV1), DLco and TLC in reconstruction algorithm B. In conclusion, reconstruction algorithm has influence to quantitative assessments on chest thin-section MDCT examination in interstitial pneumonia patients.

  8. Multislice CT imaging of pulmonary embolism

    International Nuclear Information System (INIS)

    Schoepf, J.U.; Kessler, M.A.; Rieger, C.T.; Herzog, P.; Wiesgigl, S.; Becker, C.R.; Exarhos, D.N.; Reiser, M.F.

    2001-01-01

    In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses. (orig.)

  9. Paranasal sinuses and nasopharynx CT and MRI

    International Nuclear Information System (INIS)

    Sievers, K.W.; Greess, H.; Baum, U.; Dobritz, M.; Lenz, M.

    2000-01-01

    Neoplastic disease of the nose, paranasal sinuses, the nasopharynx and the parapharyngeal space requires thorough assessment of location and extent in order to plan appropriate treatment. CT allows the deep soft tissue planes to be evaluated and provides a complement to the physical examination. It is especially helpful in regions involving thin bony structures (paranasal sinuses, orbita); here CT performs better than MRI. MRI possesses many advantages over other imaging modalities caused by its excellent tissue contrast. In evaluating regions involving predominantly soft tissue structures (ec nasopharynx and parapharyngeal space) MRI is superior to CT. The possibility to obtain strictly consecutive volume data sets with spiral CT or 3D MRI offer excellent perspectives to visualize the data via 2D or 3D postprocessing. Because head and neck tumors reside in a complex area, having a 3D model of the anatomical features may assist in the delineation of pathology. Data sets may be transferred directly into computer systems and thus be used in computer assisted surgery

  10. Paranasal sinuses and nasopharynx CT and MRI.

    Science.gov (United States)

    Sievers, K W; Greess, H; Baum, U; Dobritz, M; Lenz, M

    2000-03-01

    Neoplastic disease of the nose, paranasal sinuses, the nasopharynx and the parapharyngeal space requires thorough assessment of location and extent in order to plan appropriate treatment. CT allows the deep soft tissue planes to be evaluated and provides a complement to the physical examination. It is especially helpful in regions involving thin bony structures (paranasal sinuses, orbita); here CT performs better than MRI. MRI possesses many advantages over other imaging modalities caused by its excellent tissue contrast. In evaluating regions involving predominantly soft tissue structures (ec nasopharynx and parapharyngeal space) MRI is superior to CT. The possibility to obtain strictly consecutive volume data sets with spiral CT or 3D MRI offer excellent perspectives to visualize the data via 2D or 3D postprocessing. Because head and neck tumors reside in a complex area, having a 3D model of the anatomical features may assist in the delineation of pathology. Data sets may be transferred directly into computer systems and thus be used in computer assisted surgery.

  11. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  12. CT image reconstruction of steel pipe section from few projections using the method of rotating polar-coordinate

    International Nuclear Information System (INIS)

    Peng Shuaijun; Wu Zhifang

    2008-01-01

    Fast online inspection in steel pipe production is a big challenge. Radiographic CT imaging technology, a high performance non-destructive testing method, is quite appropriate for inspection and quality control of steel pipes. The method of rotating polar-coordinate is used to reconstruct the steel pipe section from few projections with the purpose of inspecting it online. It reduces the projection number needed and the data collection time, and accelerates the reconstruction algorithm and saves the inspection time evidently. The results of simulation experiment and actual experiment indicate that the image quality and reconstruction time of rotating polar-coordinate method meet the requirements of inspecting the steel tube section online basically. The study is of some theoretical significance and the method is expected to be widely used in practice. (authors)

  13. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  14. Evaluation of small peripheral pulmonary lesions with thin slice computed tomography

    International Nuclear Information System (INIS)

    Yamada, Kouzo

    1992-01-01

    To evaluate the morphology of small peripheral pulmonary lesions, we studied thin-slice CT (TS-CT) images of 47 small peripheral pulmonary lesions (24 lung cancers, 23 benign lesions) in 47 patients. CT images were examined by two different window and level settings (window level; -600, window width; 1900 and window level; 50, window width; 300). In TS-CT images, findings of all lesions were classified into 3 different patterns (infiltrative type, solid with air-bronchogram type, homogeneous solid type) which were useful in diagnosing histology based on the growth pattern of the lesion. There was no lung cancer case in which calcification was diagnosed to be present on TS-CT. On the other hand, 5 of 9 inflammatory granulomas were recognized to contain calcium which was never seen on conventional CT. The results suggest that TS-CT may have a significant clinical role in diagnosing small peripheral pulmonary lesion by demonstrating macroscopic features and calcification. (author)

  15. Determination of optimal parameters for three-dimensional reconstruction images of central airways using helical CT

    International Nuclear Information System (INIS)

    Hirose, Takahumi; Akata, Soichi; Matsuno, Naoto; Nagao, Takeshi; Abe, Kimihiko

    2002-01-01

    Three-dimensional (3D) image reconstruction of central airways using helical CT requires several user-defined parameters that exceed the requirements of conventional CT. The purpose of this study was to evaluate the optimal parameters for 3D images of central airways using helical CT. In our experimental study using a piglet immediately after sacrifice, 3D images of the central airway were evaluated with changes of 3D imaging parameters, such as detector collimation (1, 2, 3 and 6 mm), table speed (1, 2, 3 and 5 mm/sec), tube electric current (50, 100, 150, 200 and 250 mA), reconstruction interval (0.3, 0.5, 1, 2 and 3 mm), algorithm (mediastinum and lung) and interpolation method (180 deg and 360 deg). To minimize detector collimation, table speed, and reconstruction interval could provide the best 3D images of the central airway. Stair-step artifacts could also be reduced with a slow table speed. However, decreasing the collimation and table speed decreases not only the effective section thickness but also the scan coverage that can be achieved with a helical CT. For routine diagnosis, we conclude that optimal parameters for 3D images of the central airway are to minimize the table speed necessary to cover the volume of interest and to set detector collimation to 1/2 of the table speed. The reconstruction intervals should also be selected at up to 1/2 of the detector collimation, but with trade-offs of increased image processing time, data storage requirements, and physician time for image review. Regarding to tube electric current, 200 mA or more was necessary. Pixel noise increased with the algorithm for the lung. The 180 deg interpolation is better than 360 deg interpolation due to thin effective section thickness. (author)

  16. Basic Principles of Thin-Walled Open Bars Taking into Account Where Influence Shifts of Cross Sections are Concerned

    Science.gov (United States)

    Panasenko, N. N.; Sinelschikov, A. V.

    2017-11-01

    The finite element method is considered to be the most effective in relation to the calculation of strength and stability of buildings and engineering constructions. As a rule, for the modelling of supporting 3-D frameworks, finite elements with six degrees of freedom are used in each of the nodes. In practice, such supporting frameworks represent the thin-walled welded bars and hot-rolled bars of open and closed profiles in which cross-sectional deplanation must be taken into account. This idea was first introduced by L N Vorobjev and brought to one of the easiest variants of the thin-walled bar theory. The development of this approach is based on taking into account the middle surface shear deformation and adding the deformations of a thin-walled open bar to the formulas for potential and kinetic energy; these deformations depend on shearing stress and result in decreasing the frequency of the first tone of fluctuations to 13%. The authors of the article recommend taking into account this fact when calculating fail-proof dynamic systems.

  17. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 2

    International Nuclear Information System (INIS)

    Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter; Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof; Arnegger, Florian U.

    2011-01-01

    To compose diagnostic standard operating procedures for both clinical and imaging assessment for vulvar and vaginal cancer, for vaginal sarcoma, and for ovarian cancer. The literature was reviewed for diagnosing the above mentioned malignancies in the female pelvis. Special focus herein lies in tumor representation in MRI, followed by the evaluation of CT and PET/CT for this topic. MRI is a useful additional diagnostic complement but by no means replaces established methods of gynecologic diagnostics and ultrasound. In fact, MRI is only implemented in the guidelines for vulvar cancer. According to the current literature, CT is still the cross-sectional imaging modality of choice for evaluating ovarian cancer. PET/CT appears to have advantages for staging and follow-up in sarcomas and cancers of the ovaries. (orig.)

  18. Multiplanar CT of the spine

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Glenn, W.V. Jr.

    1986-01-01

    This is an illustrated text on computed tomography (CT) of the lumbar spine with an emphasis on the role and value of multiplanar imaging for helping determine diagnoses. The book has adequate discussion of scanning techniques for the different regions, interpretations of various abnormalities, degenerative disk disease, and different diagnoses. There is a 50-page chapter on detailed sectional anatomy of the spine and useful chapters on the postoperative spine and the planning and performing of spinal surgery with CT multiplanar reconstruction. There are comprehensive chapters on spinal tumors and trauma. The final two chapters of the book are devoted to CT image processing using digital networks and CT applications of medical computer graphics

  19. Initial experience with AcQsim CT simulator

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Gerber, Russell; Bosch, Walter R.; Harms, William; Matthews, John W.; Purdy, James A.; Perez, Carlos A.

    1995-01-01

    performed with the patient on a conventional simulator in which portal radiographs are compared against DRRs. Results: Several important issues have been identified that impact on clinical utilization of the CT simulator. Thin, finely spaced CT slices improve the DRR quality but potentially degrade the quality of cross sectional images used for image segmentation. Large data sets also increase the workload for anatomic image segmentation (contouring) and raise concerns regarding data storage and easy network access. Software for image segmentation has been significantly improved allowing rapid drawing of contours around tumor/target volumes and normal tissues and improved edit functions that allow interpolation, copying, and correction of contours. These tools have reduced the time for defining all the normal tissues and target volumes for some sites (e.g. prostate) to less than 30 minutes. Acquisition of this large volume CT data currently takes less than 30 minutes potentially reducing patient time in the simulation/planning process. Difficult simulations, such as mantle/periaortic and craniospinal fields that typically require multiple 2-3 hour simulation sessions, now take half as much time with the spiral CT scanner. Subsequent field reductions or secondary fields can be planned without the physical presence of the patient. A comparison of predicted isocenter shift coordinates and actual coordinates used for verification simulation showed that the average change in isocenter position was less than a few mm indicating that the verification process can likely be eliminated. Disadvantages of current device include limited CT ring size (70 cm) and reconstruction window (48 cm) which prevent universal application of technique to all patients. Conclusion: The AcQsim offers significant advantages over a conventional simulator in terms of patient compliance and fatigue, as well as departmental throughput. In virtual simulation, after the initial acquisition of CT data, the CT

  20. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  1. A study on usefulness of CT arthrography for the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Shumei [Osaka Univ. (Japan). School of Dentistry

    1992-06-01

    In the field of orthopedics, CT arthrography has been utilized for the shoulder and the knee joints diagnosis. In this study, CT arthrography was applied to the temporomandibular joint (TMJ) and the usefulness of this method was evaluated experimentally and clinically. In the experimental study, CT, CT arthrography and arthrotomogtaphy were compared each other with serial section from human autopsy specimen. It was confirmed that arthrography was indispensable for diagnosis of the location and configuration of the articular disk. In the sagittal section, CT arthrography was almost equal to arthrotomography. But in the coronal section, CT arthrography proved to be advantageous to arthrotomography, because there were various blur images on the arthrotomographic images from the complex bony structures of the skull. In the clinical study, coronal CT arthrography was applied for the patients with internal derangements of the TMJ. The mesio-lateral displacement of the disk (62%), perforation of the attachment (23%), and the intra-articular adhesion (70%) could be diagnosed. BY CT arthrography, the mesio-lateral displacement of the disk was more clearly diagnosed and the intra-articular adhesions were proved with higher rate than by the arthrotomography. From this study, it was concluded that CT arthrography has an important role in diagnosis of the TMJ soft tissue. (author) 51 refs.

  2. Normal CT anatomy of the calcaneus

    International Nuclear Information System (INIS)

    Lee, Mun Gyu; Kang, Heung Sik

    1986-01-01

    Normal sectional anatomy of the calcaneus with multiplanar CT examination was studied in 5 volunteers as the background for interpretation of various abnormalities. Major 3 sectional anatomy including plantar, coronal, sagittal and additional tuberosity planes are described. With CT examination of the calcaneus, 1. More detailed anatomy of 3 facets of subtalar joint (anterior, middle, and posterior facet) can be well visualized. 2. Its clinical applications in the tarsal trauma, tarsal coalition, subtalar infection, degenerative arthritis, club foot, pes planus and tarsal tumor could provide much more information's, which not obtained by conventional radiographic studies.

  3. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  4. Micro-CT analyses of historical bone samples presenting with osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Lamm, C.; Pietschmann, P. [Medical University Vienna (MUV), Department of Pathophysiology and Allergy Research, Center for Pathophysiology, Infectiology and Immunology, Vienna (Austria); Dockner, M.; Weber, G.W. [University of Vienna, Department of Anthropology, Vienna (Austria); University of Vienna, Core Facility for Micro-Computed Tomography, Vienna (Austria); Pospischek, B.; Winter, E.; Patzak, B. [Museum of Natural History (NHM), Collection of Anatomical Pathology in the Madhouse Tower, Vienna (Austria); Pretterklieber, M. [Medical University of Vienna (MUV), Department of Applied Anatomy, Vienna (Austria)

    2015-10-15

    Osteomyelitis is an inflammation of the bone marrow mainly caused by bacteria such as Staphylococcus aureus. It typically affects long bones, e.g. femora, tibiae and humeri. Recently micro-computed tomography (μCT) techniques offer the opportunity to investigate bone micro-architecture in great detail. Since there is no information on long bone microstructure in osteomyelitis, we studied historic bone samples with osteomyelitis by μCT. We investigated 23 femora of 22 individuals suffering from osteomyelitis provided by the Collection of Anatomical Pathology, Museum of Natural History, Vienna (average age 44 ±19 years); 9 femora from body donors made available by the Department of Applied Anatomy, Medical University of Vienna (age range, 56-102 years) were studied as controls. Bone microstructure was assessed by μCT VISCOM X 8060 II with a minimal resolution of 18 μm. In the osteomyelitic femora, most prominent alterations were seen in the cortical compartment. In 71.4 % of the individuals with osteomyelitis, cortical porosity occurred. 57.1 % of the individuals showed cortical thinning. In 42.9 % trabecularisation of cortical bone was observed. Osteomyelitis is associated with severe alterations of cortical bone structure otherwise typically observed at old age such as cortical porosity and cortical thinning. (orig.)

  5. CT of pancreatitis

    International Nuclear Information System (INIS)

    Fukuda, Toshio

    1990-01-01

    One hundred and two cases of acute and chronic pancreatitis were studied by computed tomography. Fluid collection was detected by CT in 45 cases, and the common extrapancreatic sites of involvement included the lesser sac (13 cases), anterior pararenal space (9 cases), transverse mesocolon (7 cases) and posterior pararenal space (5 cases). Ten cases of spontaneous resolution of pancreatic pseudocysts were encountered. Cystojejunostomy was done on 6 patients. A 4-to-6-weeks time interval has been currently accepted as necessary for pseudocyst wall maturation. However, the surgery was not possible in two patients in this series since the cyst wall was too thin. It is considered that the time over 3 months is required for surgical anastomosis of the cyst to the gastrointestinal tract. Pancreatic abscess has become the most common cause of death from pancreatitis. In this series pancreatic abscess occurred in 8 patients. Gas collection in the pancreas was observed in only one patient. In the other patients, pseudocysts had become infected and converted to abscesses. The CT number of 4 infected pseudocysts was less than 15 HU. Thus, it was not possible to distinguish infected from noninfected pseudocysts by CT. The author studied 9 patients with focal inflammatory mass of the pancreas with histologically proved severe fibrosis. All masses were small. Angiography showed occlusion or marked stenosis of the splenic vein in 3 cases. The postcontract CT (after intravenous bolus injection) in 7 cases of focal inflammatory mass demonstrated almost equal enhanced effect of the mass as compared with the adjacent normal pancreatic parenchyma. This finding is considered to be useful in distinguishing inflammatory mass from pancreatic carcinoma. (author)

  6. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  7. CT analysis of pulmonary Wegener's granulomatosis

    International Nuclear Information System (INIS)

    Liao Hualing; Chen Jianbo; Zhong Wenchen; Chen Jingdi

    2010-01-01

    Objective: To study the CT features and to improve the diagnostic accuracy of pulmonary Wegener's granulomatosis. Methods: 11 patients with histopathologically and clinically proven Wegener's granulomatosis were included in the study. Chest radiography was performed in all 11 patients and 8 patients underwent chest CT. Results: Lung abnormalities were noted in 10/11 patients including patchy lung opacities (n=3), multiple nodules (less than 3 cm in diameter, n=4), masses (more than 3cm in diameter, n=3), and cavitations (n=8). Multiple findings were observed in 4 patients. Conclusion: Imaging manifestations of pulmonary Wegener's granulomatosis were variable. Patchy lung opacities, nodules and cavitation were most common. Thin-walled cavity and ring-shaped cavity were characteristic. Pneumonia, abscess, tuberculosis and carcinoma should be included in the differential diagnosis. (authors)

  8. CT findings in skeletal cystic echinococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Tuezuen, M.; Hekimoglu, B. [Social Security Hospital, Ankara (Turkey). Dept. of Radiology

    2002-09-01

    Purpose: To evaluate the CT findings of skeletal cystic echinococcosis. Material and Methods: CT findings of 7 patients with pathologically confirmed skeletal cystic echinococcosis were evaluated. Results: There were 4 men and 3 women, aged 36-75 years. Hydatid cysts were located in the spine (n=2), a rib (n=3), the pelvis and a vertebra (n=1), the pelvis and the left femur (n=1). The size of the lesions varied from 1 cm to 15 cm. CT showed well defined, single or multiple cystic lesions with no contrast enhancement, no calcification, no daughter cysts, and no germinal membrane detachment. The cystic lesion had a honeycomb appearance in 2 cases, there was pathologic fracture in 2 cases, bone expansion in 5 cases, cortical thinning in 6 cases, cortical destruction in 6 cases, bone sclerosis in 1 case, and soft tissue extension in 6 cases. Conclusion: Preoperative differential diagnosis of skeletal cystic lesions should include cystic echinococcosis, especially in endemic areas, since this diagnosis may easily be missed unless kept in mind.

  9. Widely scattered CT lesions in the midbrain and the pons in a case of neuro-Behcet's syndrome

    International Nuclear Information System (INIS)

    Kuroiwa, Yoshiyuki; Tohgi, Hideo; Kanayama, Hiroumi; Fujimori, Masaki; Aoki, Hidehiko

    1985-01-01

    We report on a 30-year-old man with neuro-Behcet's disease. His main neurologic symptoms and signs included headache, alternating hemiparesis, dysarthria, and truncal ataxia. Lumbar puncture demonstrated an elevated pressure, pleocytosis, and an increased protein concentration. Intravenous betamethasone produced a rapid and sustained improvement, without recurrence for two years. Widely scattered foci of small, low-density lesions were disclosed in the midbrain and the pons on a cranial CT scan with 2.5 mm thin-cut slices to enable us to focus on the brainstem. Such CT lesions are consistent with the neuropathological features of this illness, which shows a tendency for brainstem lesions to predominate; these lesions probably represent necrotic areas secondary to vasculitis. Brainstem CT studies with thin-cut slices may be an important diagnostic aid in patients suspected of having neuro-Behcet's disease. (author)

  10. CT in dental osseointegration

    International Nuclear Information System (INIS)

    Witte, D.

    1992-01-01

    Computerised tomography (CT) plays a key role in the pre-surgical evaluation of the alveolar process for titanium dental implants. The successful replacement of lost teeth by tissue integrated tooth root implants is a major advance in clinical dentistry. The paper will discuss briefly the history of osseointegration and how CT is now involved in helping the edentulous patient. CT is considered as a quick and convenient method of obtaining excellent anatomical information about the maxilla. Conventional tomography is difficult to obtain and does not provide valuable cross-sectional images. Exact height and width calculations can be made as well as screening out patients with advanced bone resorption. 3 refs. 6 figs

  11. Stratigraphic charcoal analysis on petrographic thin sections: Application to fire history in northwestern Minnesota

    Science.gov (United States)

    Clark, James S.

    1988-07-01

    Results of stratigraphic charcoal analysis from thin sections of varved lake sediments have been compared with fire scars on red pine trees in northwestern Minnesota to determine if charcoal data accurately reflect fire regimes. Pollen and opaque-spherule analyses were completed from a short core to confirm that laminations were annual over the last 350 yr. A good correspondence was found between fossil-charcoal and fire-scar data. Individual fires could be identified as specific peaks in the charcoal curves, and times of reduced fire frequency were reflected in the charcoal data. Charcoal was absent during the fire-suppression era from 1920 A.D. to the present. Distinct charcoal maxima from 1864 to 1920 occurred at times of fire within the lake catchment. Fire was less frequent during the 19th century, and charcoal was substantially less abundant. Fire was frequent from 1760 to 1815, and charcoal was abundant continuously. Fire scars and fossil charcoal indicate that fires did not occur during 1730-1750 and 1670-1700. Several fires occurred from 1640 to 1670 and 1700 to 1730. Charcoal counted from pollen preparations in the area generally do not show this changing fire regime. Simulated "sampling" of the thin-section data in a fashion comparable to pollen-slide methods suggests that sampling alone is not sufficient to account for differences between the two methods. Integrating annual charcoal values in this fashion still produced much higher resolution than the pollen-slide method, and the postfire suppression decline of charcoal characteristic of my method (but not of pollen slides) is still evident. Consideration of the differences in size of fragments counted by the two methods is necessary to explain charcoal representation in lake sediments.

  12. Classication Methods for CT-Scanned Carcass Midsections

    DEFF Research Database (Denmark)

    Skytte, Jacob Lercke; Dahl, Anders Lindbjerg; Larsen, Rasmus

    2011-01-01

    Computed tomography (CT) has successfully been applied in medical environments for decades. In recent years CT has also made its entry to the industrial environments, including the slaughterhouses. In this paper we investigate classication methods for an online CT system, in order to assist...... in the segmentation of the outer fat layer in the mid- section of CT-scanned pig carcasses. Prior information about the carcass composition can potentially be applied for a fully automated solution, in order to optimize the slaughter line. The methods comprise Markov Random Field and contextual Bayesian classication...

  13. Supervised Mineral Classification with Semi-automatic Training and Validation Set Generation in Scanning Electron Microscope Energy Dispersive Spectroscopy Images of Thin Sections

    DEFF Research Database (Denmark)

    Flesche, Harald; Nielsen, Allan Aasbjerg; Larsen, Rasmus

    2000-01-01

    This paper addresses the problem of classifying minerals common in siliciclastic and carbonate rocks. Twelve chemical elements are mapped from thin sections by energy dispersive spectroscopy in a scanning electron microscope (SEM). Extensions to traditional multivariate statistical methods...

  14. CT imaging of hepatic veno-occlusive disease (an analysis 14 cases)

    International Nuclear Information System (INIS)

    Zhang Guohua; Kong Azhao; Fang Junwei; Chen Yuejing; Zheng Weiliang; Dong Danjun; Zhang Shizheng

    2006-01-01

    Objective: To probe imaging characteristics of the hepatic veno-occlusive disease (VOD) based on clinical features and abdomen CT findings. Methods: Fourteen patients including 6 male and 8 female aged from 41 to 73 years were enrolled in this study. They all had previous trauma history and notoginseng was given as herbal remedy. Dynamic enhanced CT and color Dopplor ultrasound examinations were routinely used. Two of them received venous angiography and four cases were pathologically proved as VOD after CT guided needle biopsy. Results: Hepatic swelling and ascites were found on plain CT scan. Diffuse patchy areas without enhancement indicative of poorly hepatic perfusion were found. Hepatic veins were compressed and became thin, and inferior vena cava was flat and narrow without distal dilation or collateral circulation. No obstruction of hepatic veins and inferior vena cava was found on ultrasound and venography. Conclusion: Dynamic enhanced CT is highly valuable for early assessing VOD and imaging features of venous hepatic congestion found on CT was strongly suggestive of VOD if there's previous history of treatment of gynura segetum. (authors)

  15. Optimization of PIXE-sensitivity for detection of Ti in thin human skin sections

    International Nuclear Information System (INIS)

    Pallon, Jan; Garmer, Mats; Auzelyte, Vaida; Elfman, Mikael; Kristiansson, Per; Malmqvist, Klas; Nilsson, Christer; Shariff, Asad; Wegden, Marie

    2005-01-01

    Modern sunscreens contain particles like TiO 2 having sizes of 25-70 nm and acting as a reflecting substance. For cosmetic reasons the particle size is minimized. Questions have been raised to what degree these nano particles penetrate the skin barrier, and how they do affect the human. The EU funded project 'Quality of skin as a barrier to ultra-fine particles' - NANODERM has started with the purpose to evaluate the possible risks of TiO 2 penetration into vital skin layers. The purpose of the work presented here was to find the optimal conditions for micro-PIXE analysis of Ti in thin skin sections. In the skin region where Ti is expected to be found, the naturally occurring major elements phosphorus, chlorine, sulphur and potassium have steep gradients and thus influence the X-ray background in a non-predictable manner. Based on experimental studies of Ti-exposed human skin sections using proton energies ranging from 1.8-2.55 MeV, the corresponding PIXE detection limits for Ti were calculated. The energy that was found to be the most favourable, 1.9 MeV, was then selected for future studies

  16. Three-rooted premolar analyzed by high-resolution and cone beam CT.

    Science.gov (United States)

    Marca, Caroline; Dummer, Paul M H; Bryant, Susan; Vier-Pelisser, Fabiana Vieira; Só, Marcus Vinicius Reis; Fontanella, Vania; Dutra, Vinicius D'avila; de Figueiredo, José Antonio Poli

    2013-07-01

    The aim of this study was to analyze the variations in canal and root cross-sectional area in three-rooted maxillary premolars between high-resolution computed tomography (μCT) and cone beam computed tomography (CBCT). Sixteen extracted maxillary premolars with three distinct roots and fully formed apices were scanned using μCT and CBCT. Photoshop CS software was used to measure root and canal cross-sectional areas at the most cervical and the most apical points of each root third in images obtained using the two tomographic computed (CT) techniques, and at 30 root sections equidistant from both root ends using μCT images. Canal and root areas were compared between each method using the Student t test for paired samples and 95 % confidence intervals. Images using μCT were sharper than those obtained using CBCT. There were statistically significant differences in mean area measurements of roots and canals between the μCT and CBCT techniques (P < 0.05). Root and canal areas had similar variations in cross-sectional μCT images and became proportionally smaller in a cervical to apical direction as the cementodentinal junction was approached, from where the area then increased apically. Although variation was similar in the roots and canals under study, CBCT produced poorer image details than μCT. Although CBCT is a strong diagnosis tool, it still needs improvement to provide accuracy in details of the root canal system, especially in cases with anatomical variations, such as the three-rooted maxillary premolars.

  17. Cystic thymic diseases: CT manifestations

    International Nuclear Information System (INIS)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok

    1995-01-01

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component

  18. The value of X-ray CT in orbital fractures

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Hee; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee [Catholic Medical College, Seoul (Korea, Republic of)

    1986-08-15

    On the pulse from the trauma transiting to posterior side of the orbit, orbital fractures are occurred through the weak point of the orbital wall. Invagination of soft tissue or entrapment of muscles may be associated with orbital fracture. In condition of inaccurate diagnosis, appropriate surgical repairment is impossible and complication such as diplopia or enophthalmia are developed. CT scan is diagnostic procedure which demonstrates accurately the site and state of orbital fracture, and its associated findings. The authors has been studied in 21 orbital CT scan to evaluate the relative value of plain X rays and CT scans in the diagnosis of orbital fractures during the period from January 1982 to September 1985. The conclusions were as follows: 1. Diagnostic rate was 100% by CT, 40% by initial and 80% by retrospective interpretation of conventional X-ray films. 2. Low X-ray diagnostic rate of medical wall fractures (26.7%) was due to thinness of the bone. 3. Medial wall fractures were associated with floor fractures in 46%. 4. Orbital soft tissue injuries and abnormalities of PNS were precisely evaluated by CT scan.

  19. CT evaluation of gastric cancer. Depth of tumor invasion and pancreas invasion

    International Nuclear Information System (INIS)

    Banba, Yoshihisa; Kanazawa, Tadayoshi; Seto, Hikaru

    1998-01-01

    To compare the internal structure of tumor and the contiguous organ configuration on computed tomography (CT) with the depth of tumor invasion on the pathological specimen. Sixty-four gastric cancers depicted on incremental dynamic CT were classified according to the internal structure of the tumor, and correlated with the depth of tumor invasion. In addition, the cancers were classified according to the contiguous pancreatic configuration, and correlated with the degree of pancreatic invasion. Eleven tumors with thickened gastric wall consisting of both a thick inner layer of high attenuation and a thin outer layer of low attenuation (two-layered tumor with a thin outer layer) did not invade the serosa: mucosa (n=5) and submucosa (n=6). Of 59 gastric cancers with a regular margin to the contiguous pancreas, pancreatic invasion was absent in 58 and present in one. Pancreatic invasion was present in all of five gastric cancers with an irregular margin. Our results indicate that two-layered gastric tumors with a thin outer layer never invade the serosa. Furthermore, pancreatic invasion is predicted only when the margin of the contiguous pancreas is irregular. (author)

  20. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    International Nuclear Information System (INIS)

    Needell, Steven D.; Borzykowski, Ross M.; Carreira, Dominic S.; Kozy, John

    2014-01-01

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  1. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    Energy Technology Data Exchange (ETDEWEB)

    Needell, Steven D.; Borzykowski, Ross M. [Boca Radiology Group, Boca Raton, FL (United States); Carreira, Dominic S.; Kozy, John [Broward Health Orthopedics and Sports Medicine, Fort Lauderdale, FL (United States)

    2014-11-15

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  2. Characteristic features of computed tomography (CT) in hepatic schistosomiasis japonica

    Energy Technology Data Exchange (ETDEWEB)

    Sakemi, Taisuke; Sakai, Terufumi; Majima, Yasuo [Kurume Univ., Fukuoka (Japan). School of Medicine

    1984-06-01

    Characteristic finding of CT in the liver of hepatic schistosomiasis japonica were compared with histological changes. The study was made on 7 cases with schistosomatic liver cirrhosis (SLC) and 7 SLC cases with hepatocellular carcinoma (HCC). Characteristic CT findings were high density funicular patterns showing turtle shell appearance (4 cases), high density spotty patterns (3 cases) and both mixed patterns (7 cases). These patterns were not changed by contrast medium study. Funicular and mixed patterns were observed in both lobes of the liver, however, spotty patterns were seen only in the right lobe. It was difficult to distinguish liver tissue surrounded by funicular patterns from HCC lesion. Histopathological study of autopsied livers and CT scanning of thin cut livers revealed that high density funicular patterns represent deposits of calcified schistosomal ova in the fibrous septa.

  3. Textures in spinel peridotite mantle xenoliths using micro-CT scanning: Examples from Canary Islands and France

    Science.gov (United States)

    Bhanot, K. K.; Downes, H.; Petrone, C. M.; Humphreys-Williams, E.

    2017-04-01

    Spinel pyroxene-clusters, which are intergrowths of spinel, orthopyroxene and clinopyroxene in mantle xenoliths, have been investigated through the use of micro-CT (μ-CT) in this study. Samples have been studied from two different tectonic settings: (1) the northern Massif Central, France, an uplifted and rifted plateau on continental lithosphere and (2) Lanzarote in the Canary Islands, an intraplate volcanic island on old oceanic lithosphere. μ-CT analysis of samples from both locations has revealed a range of spinel textures from small Lanzarote are regions that have experienced significant lithospheric thinning. This process provides a mechanism where the sub-solidus reaction of olivine + garnet = orthopyroxene + clinopyroxene + spinel is satisfied by providing a pathway from garnet peridotite to spinel peridotite. We predict that such textures would only occur in the mantle beneath regions that show evidence of thinning of the lithospheric mantle. Metasomatic reactions are seen around spinel-pyroxene clusters in some Lanzarote xenoliths, so metasomatism post-dated cluster formation.

  4. Overranging at multisection CT: an underestimated source of excess radiation exposure.

    NARCIS (Netherlands)

    Schilham, A.; Molen, A.J. van der; Prokop, M.; Jong, H.W. de

    2010-01-01

    To reconstruct the first and last sections of a helical computed tomographic (CT) scan, the scan length is automatically extended beyond the planned image boundaries, a phenomenon known as overranging. With common 16-section CT scanning protocols, the overrange length is between 3 and 6 cm. For

  5. Patient position matching between SPECT and CT

    International Nuclear Information System (INIS)

    Eubig, C.; Lodhi, L.M.; Trueblood, J.H.; Kingsbury, T.; Burke, G.; Flickenger, F.

    1990-01-01

    Since the authors had previously developed an ability for accurate repositioning of patients by means of video imaging of their external features, it was their purpose to determine if separate video systems placed in SPECT and CT rooms could be positioned and a calibration procedure for each modality developed to assure easy identification and acquisition of corresponding congruent axial image sections through the patient. A video frame grabber is used to acquire an image of the patient in one room and superimpose it on a similar image of the patient in the other room. A radioactive ruler visible at CT images obtained with a gamma camera computer, and a CT scout image are used to adjust the initial relative position of the video cameras and calibrate the acquisition parameters of both systems. The success of this alignment procedure was tested with a body phantom. The body phantom studies indicate that this method of positioning the patient and acquiring corresponding aligned CT and SPECT axial sections can be successful where internal organ shift between the acquisitions is minimal. This should lead to a reduction of the time and computer resources necessary to fuse or superimpose images of corresponding patient sections acquired with different modalities

  6. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  7. CT appearance of pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Im, Jung Gi; Han, Man Chung; Chin, Soo Yil [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1984-03-15

    Pulmonary ligament consists of 2 serosal of pleura that connect the lower to the mediastinum. Author analyse and present CT appearance of pulmonary ligament of the 40 normal and abnormal patients on the basis of anatomic knowledge from the cross section of cadaver. Left pulmonary ligament is more frequency visualized than the right. The most important CT landmark in localizing pulmonary ligament is the esophagus where the ligament attaches on its lateral wall. Pitfalls in CT identification of pulmonary ligament are right phrenic nerve and right pericardiacophrenic vessels which emerge from lateral wall of the IVC and wall of the emphysematous bulla in the region of the pulmonary ligament.

  8. CT appearance of pulmonary ligament

    International Nuclear Information System (INIS)

    Im, Jung Gi; Han, Man Chung; Chin, Soo Yil

    1984-01-01

    Pulmonary ligament consists of 2 serosal of pleura that connect the lower to the mediastinum. Author analyse and present CT appearance of pulmonary ligament of the 40 normal and abnormal patients on the basis of anatomic knowledge from the cross section of cadaver. Left pulmonary ligament is more frequency visualized than the right. The most important CT landmark in localizing pulmonary ligament is the esophagus where the ligament attaches on its lateral wall. Pitfalls in CT identification of pulmonary ligament are right phrenic nerve and right pericardiacophrenic vessels which emerge from lateral wall of the IVC and wall of the emphysematous bulla in the region of the pulmonary ligament

  9. Thin films and nanomaterials

    International Nuclear Information System (INIS)

    Jayakumar, S.; Kannan, M.D.; Prasanna, S.

    2012-01-01

    The objective of this book is to disseminate the most recent research in Thin Films, Nanomaterials, Corrosion and Metallurgy presented at the International Conference on Advanced Materials (ICAM 2011) held in PSG College of Technology, Coimbatore, India during 12-16 December 2011. The book is a compilation of 113 chapters written by active researchers providing information and critical insights into the recent advancements that have taken place. Important new applications are possible today in the fields of microelectronics, opto-electronics, metallurgy and energy by the application of thin films on solid surfaces. Recent progress in high vacuum technology and new materials has a remarkable effect in thin film quality and cost. This has led to the development of new single or multi-layered thin film devices with diverse applications in a multitude of production areas, such as optics, thermal barrier coatings and wear protections, enhancing service life of tools and to protect materials against thermal and atmospheric influence. On the other hand, thin film process techniques and research are strongly related to the basic research activities in nano technology, an increasingly important field with countless opportunities for applications due to the emergence of new properties at the nanoscale level. Materials and structures that are designed and fabricated at the nano scale level, offer the potential to produce new devices and processes that may enhance efficiencies and reduce costs in many areas, as photovoltaic systems, hydrogen storage, fuel cells and solar thermal systems. In the book, the contributed papers are classified under two sections i) thin films and ii) nanomaterials. The thin film section includes single or multi layer conducting, insulating or semiconducting films synthesized by a wide variety of physical or chemical techniques and characterized or analyzed for different applications. The nanomaterials section deals with novel or exciting materials

  10. Contrasting Nature of Magnetic Anomalies over Thin Sections Made out of Barrandien’s Basaltic Rocks Points to their Origin

    Czech Academy of Sciences Publication Activity Database

    Kletetschka, Günther; Pruner, Petr; Schnabl, Petr; Šifnerová, Kristýna

    -, special issue (2012), s. 69-70 ISSN 1335-2806. [Castle meeting New Trends in Geomagnetism : Paleo, rock and environmental magnetism/13./. 17.06.2012-23.06.2012, Zvolen] R&D Projects: GA ČR GAP210/10/2351 Institutional support: RVO:67985831 Keywords : magnetic anomalies * thin sections * volcanic rocks Subject RIV: DE - Earth Magnetism, Geodesy, Geography http://gauss.savba.sk/GPIweb/conferences/Castle2012/abstrCastle.pdf

  11. High-resolution CT in eosinophilic granuloma (histiocytosis X) of the lung

    International Nuclear Information System (INIS)

    Godwin, J.D.; Buschman, D.L.; Moore, A.D.A.; Muller, N.L.; Naidich, D.P.; Carvalho, C.R.R.; Takasugi, J.E.; Schmidt, R.A.

    1988-01-01

    Eosinophilic granuloma of the lung is fascinating but poorly understood. Computed tomographic (CT) scans in 18 cases (11 high resolution) showed a variety of striking patterns: cysts up to 4 cm with thin or indiscernible walls, ranging from a few lesions to confluent honeycombing; retriculonodular infiltrate; and nodules 2 mm-2cm, sometimes cavitated. CT showed that the ill-defined lucencies barely visible on radiographs are indeed cysts, rather than preserved normal lung surrounded by infiltrate. High-resolution CT showed that some of the early, small nodules were concentrated along terminal bronchioles within the secondary lobules. The differential diagnosis includes sarcoidosis and idiopathic fibrosis, but the prominent cystic abnormality and the lack of peripheral concentration help to distinguish eosinophilic granuloma

  12. Borrmann type IV adenocarcinoma versus gastric lymphoma : spiral CT evaluation

    International Nuclear Information System (INIS)

    Seo, Bo Kyoung; Kim, Yun Hwan; Shin, Kue Hee; Hong, Suk Joo; Kim, Hong Weon; Park, Cheol Min; Chung, Kyoo Byung; Cho, Hyun Deuk

    1999-01-01

    To distinguish the spiral CT findings of Borrmann type IV adenocarcinoma from those of gastric lymphoma with diffuse gastric wall thickening. We retrospectively reviewed the spiral CT scans of 30 patients with Borrmann type IV adenocarcinoma and nine with gastric lymphoma with diffuse gastric wall thickening. In all patients the respective condition was pathologically confirmed by gastrectomy. CT scanning was performed after peroral administration of 500-700ml of water. A total of 120-140 ml bolus of nonionic contrast material was administered intravenously at a flow rate of 3 ml/sec and two-phase images were obtained at 35-45 sec(early phase) and 180 sec(delayed phase) after the start of bolus injection. Spiral CT was performed with 10mm collimation, 10mm/sec table feed and 10mm reconstruction. We evaluated the degree and homogeneity of enhancement of thickened entire gastric wall, and the enhancement pattern of gastric inner layer, as seen on early-phase CT scans. On early and delayed views, the thickness of gastric wall and the presence of perigastric fat infiltration were determined. The enhancement patterns of gastric inner layer were classified as either continuous or discontinuous thick enhancement, thin enhancement, or nonenhancement. The thickness of gastric wall was 1.2-3.5cm(mean 2.2cm) in cases of adenocarcinoma and 1.2-7.6cm(mean 4cm) in lymphoma. Perigastric fat infiltration was seen in 24 patients with adenocarcinoma(80%) and four with lymphoma(44%). In those with adenocarcinoma, the degree of enhancement of entire gastric wall was hyperdense in fifteen patients(50%) and isointense in eleven (37%). Seven patients with lymphoma(78%)showed hypodensity. In those with adenocarcinoma, continuous thick enhancement of gastric inner layer was seen in 18 patients(60%) and discontinuous thick enhancement in nine(30%). In lymphoma cases, no thick enhancement was observed. Thin enhancement of gastric inner layer was demonstrated in three patients with

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... special computer program processes this large volume of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT imaging is sometimes compared to looking into ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... time, resulting in more detail and additional view capabilities. Modern CT scanners are so fast that they ...

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT ... very much like other x-ray examinations. Different body parts absorb the x-rays in varying degrees. ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT ... very much like other x-ray examinations. Different body parts absorb the x-rays in varying degrees. ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT ... very much like other x-ray examinations. Different body parts absorb the x-rays in varying degrees. ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... therapy for brain cancer. In emergency cases, it can reveal internal injuries and bleeding quickly enough to ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... painless, noninvasive and accurate. In emergency cases, it can reveal internal injuries and bleeding quickly enough to ... cross-sectional images generated during a CT scan can be reformatted in multiple planes, and can even ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... path. A special computer program processes this large volume of data to create two-dimensional cross-sectional ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the examination table will move during the scan, so that the x-ray beam follows a spiral ... and additional view capabilities. Modern CT scanners are so fast that they can scan through large sections ...

  10. 33 CFR 100.102 - Great Connecticut River Raft Race, Middletown, CT.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Great Connecticut River Raft Race, Middletown, CT. 100.102 Section 100.102 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND... Raft Race, Middletown, CT. (a) Regulated Area. That section of the Connecticut River between Dart...

  11. Hemorrhagic myocardial infarction after reperfusion detected by X-ray CT

    International Nuclear Information System (INIS)

    Tamura, Tsutomu; Toyoki, Takaaki; Ishikawa, Tomoko

    1992-01-01

    The purpose of this study was to determine whether computed tomography (CT) can detect hemorrhagic infarction occurring after intracoronary thrombolytic therapy (ICT) for acute myocardial infarction (AMI). In an experimental study, 12 dogs underwent 2-4 h of left anterior descending artery (LAD) occlusion, followed by reperfusion, and infusion of contrast material into the LAD. After CT examination, the heart was cut into transverse sections. A good correlation was obtained between the CT-enhanced area and the hemorrhagic area in the sliced heart section (r=0.895, p 0.1). The SPECT defect areas were consistently smaller than the CT enhancement areas. These results indicate that CT can detect hemorrhage into the myocardium after ICT, and that after ICT half the AMI patients showed hemorrhagic infarction. However, hemorrhage did not cause complete deterioration of the myocardium. (author)

  12. Endobronchial valves in severe emphysematous patients: CT evaluation of lung fissures completeness, treatment radiological response and quantitative emphysema analysis

    Energy Technology Data Exchange (ETDEWEB)

    Koenigkam-Santos, Marcel, E-mail: marcelk46@yahoo.com.br, E-mail: marcelk46@usp.b [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Hospital das Clinicas da Faculdade de Medicina; Paula, Wagner Diniz de [University of Brasilia (UnB), DF (Brazil). Brasilia University Hospital; Gompelmann, Daniela [University of Heidelberg (Germany). Department of Pneumology and Respiratory Medicine of the Chest Clinic (Thoraxklinik); Kauczor, Hans-Ulrich [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology; Heussel, Claus Peter; Puderbach, Michael [University of Heidelberg (Germany). Department of Diagnostic and Interventional Radiology with Nuclear Medicine of the Chest Clinic (Thoraxklinik)

    2013-01-15

    Objective: To evaluate lung fissures completeness, post-treatment radiological response and quantitative CT analysis (QCTA) in a population of severe emphysematous patients submitted to endobronchial valves (EBV) implantation. Materials and Methods: Multi-detectors CT exams of 29 patients were studied, using thin-section low dose protocol without contrast. Two radiologists retrospectively reviewed all images in consensus; fissures completeness was estimated in 5% increments and post-EBV radiological response (target lobe atelectasis/volume loss) was evaluated. QCTA was performed in pre and post-treatment scans using a fully automated software. Results: CT response was present in 16/29 patients. In the negative CT response group, all 13 patients presented incomplete fissures, and mean oblique fissures completeness was 72.8%, against 88.3% in the other group. QCTA most significant results showed a reduced post-treatment total lung volume (LV) (mean 542 ml), reduced EBV-submitted LV (700 ml) and reduced emphysema volume (331.4 ml) in the positive response group, which also showed improved functional tests. Conclusion: EBV benefit is most likely in patients who have complete interlobar fissures and develop lobar atelectasis. In patients with no radiological response we observed a higher prevalence of incomplete fissures and a greater degree of incompleteness. The fully automated QCTA detected the post-treatment alterations, especially in the treated lung analysis. (author)

  13. Normal cranial CT anatomy

    International Nuclear Information System (INIS)

    Gado, M.H.; Rao, K.C.V.G.

    1987-01-01

    The human brain consists of well-known anatomical components. Some parts of these components have been shown to be concerned with certain functions. A complete cranial CT examination consists of a series of several slices obtained in a sequence usually from the base to the vertex of the cranial vault, in the axial mode. The ultimate goal of this chapter is to pinpoint those slices that depict a given anatomical structure or several structures that deal with a given function. To achieve this goal, the discussion of CT cranial anatomy is presented in three sections

  14. Improved CT imaging in diagnosis of ankylosing spondylitis

    International Nuclear Information System (INIS)

    Mai Yuanfeng; Sun Haixing; Ling Jian; Kuang Jianyi; Pan Ximin

    2006-01-01

    Objective: To evaluate the improved CT imaging of sacroiliac joint in diagnosis of ankylosing spondylitis (AS). Methods: 22 patients, diagnosed as AS by clinical and radiography, undertook both conventional and improved CT imaging. All images were comparatively studied. Results: With conventional CT imaging, in the 44 joints of 22 cases, unremarkable images were obtained in 3 cases; early stage AS was found in 15 joints of 9 cases; AS in progressive stage was revealed in 8 cases/16 joints, stabled AS was presented in 2 cases/4 joints. There were 23 joints in 12 cases diagnosed as early term by improved imaging, progressive staged AS was shown in 8 cases/16 joints as, stable AS was demonstrated in 2 cases/4 joints. Conclusion: The improved imaging is sensitive in the diagnosis of early staged AS, for the application of thin slice scan, which helps to reduce partial volume effect. Scanning along the longitudinal axis of the sacroiliac joint extends the observation of erosion of the joint surface. For progressive or stable staged AS, the alterations of bone and joint space are prominent, improved CT imaging is not superior to the conventional. (authors)

  15. CT findings of muscular dystrophy

    International Nuclear Information System (INIS)

    Saitoh, Hiroshi

    1991-01-01

    CT scans of muscles in patients with limb girdle type (LG), myotonic type (MYD) and Duchenne type (DMD) dystrophies were obtained at five different body levels: the neck, L3 vertebral body, pelvic girdle, thigh and lower leg. CT numbers, cross sectional areas (CSA) and %CSA of muscle or fat were evaluated in each muscle. The characteristic CT patterns for each type of muscular dystrophy were obtained. Compared with DMD, the gracilis and soleus were more severely damaged in LG and the biceps femoris remained relatively preserved among the hamstrings. In addition, the multifidus of the neck and sternocleidomastoid also were more severely damaged in MYD. This study suggests that CT scan will be useful in the differential diagnosis of these types of muscular dystrophy as well as in planning appropriate rehabilitation and detecting damaged muscles. (author)

  16. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  17. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  18. CT quantification of central airway in tracheobronchomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Im, Won Hyeong; Jin, Gong Yong; Han, Young Min; Kim, Eun Young [Dept. of Radiology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)

    2016-05-15

    To know which factors help to diagnose tracheobronchomalacia (TBM) using CT quantification of central airway. From April 2013 to July 2014, 19 patients (68.0 ± 15.0 years; 6 male, 13 female) were diagnosed as TBM on CT. As case-matching, 38 normal subjects (65.5 ± 21.5 years; 6 male, 13 female) were selected. All 57 subjects underwent CT with end-inspiration and end-expiration. Airway parameters of trachea and both main bronchus were assessed using software (VIDA diagnostic). Airway parameters of TBM patients and normal subjects were compared using the Student t-test. In expiration, both wall perimeter and wall thickness in TBM patients were significantly smaller than normal subjects (wall perimeter: trachea, 43.97 mm vs. 49.04 mm, p = 0.020; right main bronchus, 33.52 mm vs. 42.69 mm, p < 0.001; left main bronchus, 26.76 mm vs. 31.88 mm, p = 0.012; wall thickness: trachea, 1.89 mm vs. 2.22 mm, p = 0.017; right main bronchus, 1.64 mm vs. 1.83 mm, p = 0.021; left main bronchus, 1.61 mm vs. 1.75 mm, p = 0.016). Wall thinning and decreased perimeter of central airway of expiration by CT quantification would be a new diagnostic indicators in TBM.

  19. Clinical and radiological features of bronchiolitis obliterans in children

    International Nuclear Information System (INIS)

    Peng Yun; Sun Guoqiang; Zeng Jinjin; Ma Daqing

    2006-01-01

    Objective: To study the value of chest radiograph and thin-section computed tomography (CT) in diagnosis bronchiolitis obliterans in children, and to determine clinical view of obliterative bronchiolitis in children. Methods: We identified 12 infants, 10 boys, and 2 girls (age range, 5 month to 11 years) with clinical confirmation of bronchiolitis obliterans. Three cases were after Steven-Johnson syndrome, 8 were post-infection (2 adenovirus, 2 measles and 1 Pseudomonas aeruginosa infection, 3 cases were unknown etiology infection); The symptoms lasted for at least 6 weeks. One case had lung ventilation nuclear scan. We evaluated individual bronchoscopy, pulmonary function test, chest radiograph and thin- section CT features and their characteristic appearance. Results: All cases had typical clinical characteristics and pulmonary function testing results that were consistent with nonreversible small airways obstruction. One case had lung ventilation nuclear scan illustrated absent and reduced ventilation of the right lower lobe. Nine cases who underwent bronchoscopy were chronic endobronchial inflammation. Three children had transbronchial biopsy and 1 patient who underwent open pulmonary biopsies were uncertain of histological diagnosis. Chest radiography showed hyperinflation in 8 cases; peribronchial thickening in 6 cases; consolidation/atelectasia in 6 cases; unilateral hyperlucency of a small/normal-sized lung in 4 cases. Thin-section CT/HRCT features included: mosaic perfusion pattern, decreased lung attenuation in 11 cases, pulmonary vascular attenuation in 10 cases; bronchial dilatation in 7 cases; bronchial wall thickening in 9 cases; unilateral hyperlucency of a small/normal-sized lung in 5 cases; consolidation in 6 cases; nodular in 3 cases; mucoid impaction in 5 cases. Conclusions: In our study, correct diagnoses of bronchiolitis obliterans in children were made more special with thin-section CT than with chest radiographs. The diagnosis of BO in

  20. Rapid reformatting of cine CT data

    International Nuclear Information System (INIS)

    Wyatt, E.D.; Reynolds, R.A.

    1989-01-01

    Cine CT scanners acquire data sufficiently rapidly to freeze the cardiac motion. Display hardware with sufficient highspeed computer memory permits instantaneous reformatting of sections at any orientation. Normal or abnormal cardiac motion may be studies interactively along any axial, sagittal, coronal, or oblique plane through the beating heart. Cine Ct studies, consisting of eight levels through the heart with 8-mm interlevel spacing, acquired at 10 time intervals for a total of 80 sections, were acquired on an Imatron C-100 scanner and displayed. Each entire study was loaded into t = internal display processor memory, permitting instantaneous recall without loss of spatial or density resolution. Results are presented

  1. Practical textbook of cardiac CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Tae-Hwan (ed.) [ASAN Medical Center, Seoul (Korea, Republic of). Dept. of Radiology

    2015-04-01

    Guide to the interpretation of cardiac CT and MRI for the purposes of diagnosis, treatment planning, and follow-up. Emphasis on applications in a wide range of real clinical situations. Numerous informative illustrations. Summarizing sections permitting rapid retrieval of information. QR codes allowing access to references, additional figures, and motion pictures from the internet. This up-to-date textbook comprehensively reviews all aspects of cardiac CT and MRI and demonstrates the value of these techniques in clinical practice. A wide range of applications are considered, including imaging of atherosclerotic and non-atherosclerotic coronary artery disease, coronary revascularization, ischemic heart disease, non-ischemic cardiomyopathy, valvular heart disease, cardiac tumors, and pericardial disease. The numerous high-quality images illustrate how to interpret cardiac CT and MRI correctly for the purposes of diagnosis, treatment planning, and follow-up. Helpful summarizing sections in every chapter will facilitate rapid retrieval of information. This book will be of great value to radiologists and cardiologists seeking a reliable guide to the optimal use of cardiac CT and MRI in real clinical situations.

  2. Practical textbook of cardiac CT and MRI

    International Nuclear Information System (INIS)

    Lim, Tae-Hwan

    2015-01-01

    Guide to the interpretation of cardiac CT and MRI for the purposes of diagnosis, treatment planning, and follow-up. Emphasis on applications in a wide range of real clinical situations. Numerous informative illustrations. Summarizing sections permitting rapid retrieval of information. QR codes allowing access to references, additional figures, and motion pictures from the internet. This up-to-date textbook comprehensively reviews all aspects of cardiac CT and MRI and demonstrates the value of these techniques in clinical practice. A wide range of applications are considered, including imaging of atherosclerotic and non-atherosclerotic coronary artery disease, coronary revascularization, ischemic heart disease, non-ischemic cardiomyopathy, valvular heart disease, cardiac tumors, and pericardial disease. The numerous high-quality images illustrate how to interpret cardiac CT and MRI correctly for the purposes of diagnosis, treatment planning, and follow-up. Helpful summarizing sections in every chapter will facilitate rapid retrieval of information. This book will be of great value to radiologists and cardiologists seeking a reliable guide to the optimal use of cardiac CT and MRI in real clinical situations.

  3. Significance of head CT in neuro-ophthalmology

    International Nuclear Information System (INIS)

    Nishimoto, Yuichiro; Masuyama, Yoshimasa; Nakamura, Yasuko; Fujimoto, Toshiro.

    1979-01-01

    It is important to perform CT purposefully in patients with some neuro-ophthalmological disorders. Using Hitachi CT-H250 with the finer matrix of 256 x 256 and a section thickness of 5 mm and 10 mm, we performed head CT in 98 patients with various kinds of neuro-ophthalmological disorders in these 30 months. Neuro-ophthalmological findings in these patients were visual disturbance, visual field defects (hemianopsia, quandrantanopsia, enlargement of the blind spot, central scotoma), papilledema, optic nerve atrophy, difficulties in ocular movements, and others. In 44 (44.9%) of these 98 patients, abnormal findings were displayed in the head CT, characterizing intracranial tumors, intracranial infarction, aneurysms in intracranial vessels, arterio-venous malformation, enlargement of the ventricle or the cistern. In some cases the head CT was the decisive procedure in ensuring a correct diagnosis. We presented findings in the head CT in several interesting cases. We recognized the necessity of the head CT in patients with neuro-ophthalmological disorders. (author)

  4. Breast multidetector-row CT with histopathologic correlation

    International Nuclear Information System (INIS)

    Takeuchi, Makiko; Yamashita, Akiyoshi; Ohgi, Kazuyuki; Kobori, Kenichi; Furukawa, Takashi

    2004-01-01

    The purpose of this study was to evaluate the correlation between multidetector-row CT (MDCT) and histopathologic findings using the same MDCT image as the histopathologic cross-section. MDCT with contrast enhancement was performed in 10 patients with breast cancers (8 invasive ductal carcinomas, one invasive lobular carcinoma, and one non-invasive ductal carcinoma). We tried to reconstruct multiplanar reconstructions (MPR) in the same plane as the histopathologic cross-section, and we evaluated the histopathologic findings of the false-positive lesions. In all cases, we obtained the same MDCT image as the histopathologic cross-section. There were 10 main lesions and 18 other lesions. In the other lesions, we found no false-negative lesions and 11 false-positive lesions. False-positive lesions included periductal fibrosis, cystic change, duct papillomatosis, sclerosing adenosis, fibroadenoma, and others. Using MDCT of the breast, it is possible to obtain good correlation between CT images and histopathologic findings. MDCT is thought to be useful in the evaluation CT findings on the basis of histopathologic evidence. (author)

  5. Correlative 3D-imaging of Pipistrellus penis micromorphology: Validating quantitative microCT images with undecalcified serial ground section histomorphology.

    Science.gov (United States)

    Herdina, Anna Nele; Plenk, Hanns; Benda, Petr; Lina, Peter H C; Herzig-Straschil, Barbara; Hilgers, Helge; Metscher, Brian D

    2015-06-01

    Detailed knowledge of histomorphology is a prerequisite for the understanding of function, variation, and development. In bats, as in other mammals, penis and baculum morphology are important in species discrimination and phylogenetic studies. In this study, nondestructive 3D-microtomographic (microCT, µCT) images of bacula and iodine-stained penes of Pipistrellus pipistrellus were correlated with light microscopic images from undecalcified surface-stained ground sections of three of these penes of P. pipistrellus (1 juvenile). The results were then compared with µCT-images of bacula of P. pygmaeus, P. hanaki, and P. nathusii. The Y-shaped baculum in all studied Pipistrellus species has a proximal base with two club-shaped branches, a long slender shaft, and a forked distal tip. The branches contain a medullary cavity of variable size, which tapers into a central canal of variable length in the proximal baculum shaft. Both are surrounded by a lamellar and a woven bone layer and contain fatty marrow and blood vessels. The distal shaft consists of woven bone only, without a vascular canal. The proximal ends of the branches are connected with the tunica albuginea of the corpora cavernosa via entheses. In the penis shaft, the corpus spongiosum-surrounded urethra lies in a ventral grove of the corpora cavernosa, and continues in the glans under the baculum. The glans penis predominantly comprises an enlarged corpus spongiosum, which surrounds urethra and baculum. In the 12 studied juvenile and subadult P. pipistrellus specimens the proximal branches of the baculum were shorter and without marrow cavity, while shaft and distal tip appeared already fully developed. The present combination with light microscopic images from one species enabled a more reliable interpretation of histomorphological structures in the µCT-images from all four Pipistrellus species. © 2015 Wiley Periodicals, Inc.

  6. [Osteo-odonto-kerato-prosthesis. Radiographic, CT and MR features].

    Science.gov (United States)

    Bellelli, A; Avitto, A; Liberali, M; Iannetti, F; Iannetti, L; David, V

    2001-09-01

    Osteo-odonto-keratoprosthesis, a complex eye surgery technique devised by Strampelli, provides a valuable opportunity to restore vision in patients with severe corneal opacification (chemical or thermal burns, bullous keratopathy, severe keratitis, consequences of perforating injuries) in whom corneal transplant or the insertion of synthetic prostheses is contraindicated because of the high risk of rejection. Successful implantation of corneal prostheses in these patients was clearly dependent on the use of perfectly biocompatible materials to support the optic. Strampelli demonstrated that thin autologous tooth sections, complete with alveolar-dental ligament fulfilled these requirements, and integrated perfectly with the eye tissues without any risk of rejection. This study aims to present the radiological aspects and postoperative outcome of 13 patients who received osteo-odonto-keratoprosthesis (bilateral in 11 cases and monolateral in 2) evaluated by plain radiography, CT and MRI. Between 1993 and 2001 we evaluated 13 patients who had undergone Strampelli's osteo-odonto-keratoprosthesis, using CT, plain radiography and MRI. All patients were examined by plain radiography; 11 patients were also examined by CT and 8 also by MRI. The time interval between surgery and the radiological evaluation ranged from 3 to 13 years with a mean follow-up of 5 years and 9 months. All patients underwent periodic clinical and imaging examinations in the post-operative period to evaluate the osteo-dental implant and to study trophism of the transplant. No post-operative complications, either cicatricial, inflammatory or of any other nature, were clinically suspected. Only two patients showed partial reabsorption of the osteo-dental lamina - evident both on plain film and CT - 10 and 12 years after surgery. Vision was restored in all the patients, with visual acuity of 10/10 in 7 cases. Plain radiography allows to correctly evaluate the position of the prosthesis and detect

  7. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma.

    Science.gov (United States)

    Horger, M; Fritz, J; Thaiss, W M; Ditt, H; Weisel, K; Haap, M; Kloth, Christopher

    2018-03-01

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ( WB MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p quantitative parameters with either CT or MRI.

  8. CT anatomy of hilar lymphadenopathy

    International Nuclear Information System (INIS)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J.; Monden, Y.; Nahakara, K.

    1983-01-01

    The normal distributions of lymph nodes in the pulmonary hili is diagrammatically shown with a typical computed tomographic (CT) demonstration of hilar lymphadenopathy. On the basis of observations in anatomic cross sections of cadaver lungs, the lympth nodes in the right lung can be divided into four principal groups (right upper lobe, interlobar, middle lobe, and lower lobe) and in the left lung into three principal groups (left upper lobe, interlobar, and lower lobe). Most of the hilar lymph nodes are situated along the bronchi in close relation with the pulmonary vascular branches. Because of this close proximity, contrast-enhanced CT images are indispensable for precise CT interpretation of a hilar lymphadenopathy

  9. Usefulness of Reformatted CT Rib Series in Patients with Thoracic Trauma

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sung Nam; Park, Seong Hoon; Kim, Na Hyung; Juhng, Seon Kwan; Yoon, Kwon Ha [Dept. of Radiology and Institute for Radiological Imaging Science, Wonkwang University School of Medicine, Iksan (Korea, Republic of); Bang, Dong Ho [Dept. of Radiology, Aerospace Medical Center, Cheongwon (Korea, Republic of)

    2013-01-15

    To assess the value of adding a reformatted computed tomography (CT) rib series to transversely reconstructed CT imaging in the evaluation of rib fractures in patients with suspected traumatic thoracic injuries. One hundred consecutive patients with suspected traumatic thoracic injuries underwent 128-section multi-detector row CT. Transverse CT images with 5-mm-thick sections were reconstructed and rib series were reformatted using isotropic vogel data. Three independent radiologists, who were blinded to the data, interpreted the CT scans at 2 sessions with a 4-week interval between the sessions. Only transverse CT images were reviewed at the first session. At the second session, the CT images were reviewed along with the reformatted CT rib series. The following parameters were analyzed: receiver operating characteristic (Roc) curve, pairwise comparisons of Roc curves, sensitivity, specificity, positive predictive value, and negative predictive value. There were 153 rib fractures in 29 patients. The level of the area under the Roc curve, Az improved for all observers. The diagnostic sensitivity and specificity of each observer tended to improve in the second session. The mean confidence scores for all observers of patients with rib fractures improved significantly in the second session. A reformatted CT rib series together with transverse CT scan is useful for the evaluation of rib fracture.

  10. Cystic thymic diseases: CT manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Song, Soon Young; Choi, Yo Won; Jeon, Eui Yong; Jeon, Seok Chol; Seo, Heung Suk; Hahm, Chang Kok [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-09-15

    To describe CT findings and differential points of cystic thymic lesions. We evaluated retrospectively total 19 masses with well marginated cystic lesions at thymic area on CT scans. They were 10 teratomas, 3 congenital thymic cysts, 2 multilocular thymic cysts(associated with thymoma and myasthenia gravis in each), 2 cysts Assciated with thymic Hodgkin's lymphomas an ectopic parathyroid cyst, and an infected thymic cyst. The radiological abnormalities evaluated were thickness of the wall, presence or abscene of septa, mural nodule, solid component, calcification and fat component. All three cases of congenital thymic cysts and an ectopic parathyroid cyst appeared as thin-walled unilocular cyst with homogeneous internal density and without identifiable solid component. In multilocular thymic cyst, there were thick wall and solid components(n =2), thick internal septa and calcifications(n = 1). The cysts of teratomas manifested thick walls(n = 9), internal septa(n = 4), calcifications(n = 6), fat components(n = 4), and solid components(n = 4). Cysts in Hodgkin's diseases appeared as multilocular or unilocular and had thick wall and septa without calcification. Infected thymic cyst presented with multilocular cystic mass with identifiable wall and septa, calcification, and solid components. The thymic diseases with cystic lesion include teratomas, congenital thymic cysts, multilocular thymic cysts, parathyroid cyst, and Hodgkin's disease. Congenital thymic cyst and ectopic parathyroid cyst are thin-walled unilocular cystic lesions. Cystic lesions associated with teratoma, Hodgkin's disease, and multilocular thymic cyst are thick-walled cystic lesions with or without solid component.

  11. Coronary Stent Artifact Reduction with an Edge-Enhancing Reconstruction Kernel - A Prospective Cross-Sectional Study with 256-Slice CT.

    Science.gov (United States)

    Tan, Stéphanie; Soulez, Gilles; Diez Martinez, Patricia; Larrivée, Sandra; Stevens, Louis-Mathieu; Goussard, Yves; Mansour, Samer; Chartrand-Lefebvre, Carl

    2016-01-01

    Metallic artifacts can result in an artificial thickening of the coronary stent wall which can significantly impair computed tomography (CT) imaging in patients with coronary stents. The objective of this study is to assess in vivo visualization of coronary stent wall and lumen with an edge-enhancing CT reconstruction kernel, as compared to a standard kernel. This is a prospective cross-sectional study involving the assessment of 71 coronary stents (24 patients), with blinded observers. After 256-slice CT angiography, image reconstruction was done with medium-smooth and edge-enhancing kernels. Stent wall thickness was measured with both orthogonal and circumference methods, averaging thickness from diameter and circumference measurements, respectively. Image quality was assessed quantitatively using objective parameters (noise, signal to noise (SNR) and contrast to noise (CNR) ratios), as well as visually using a 5-point Likert scale. Stent wall thickness was decreased with the edge-enhancing kernel in comparison to the standard kernel, either with the orthogonal (0.97 ± 0.02 versus 1.09 ± 0.03 mm, respectively; pkernel generated less overestimation from nominal thickness compared to the standard kernel, both with the orthogonal (0.89 ± 0.19 versus 1.00 ± 0.26 mm, respectively; pkernel was associated with lower SNR and CNR, as well as higher background noise (all p kernel. Stent visual scores were higher with the edge-enhancing kernel (pkernel generates thinner stent walls, less overestimation from nominal thickness, and better image quality scores than the standard kernel.

  12. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  13. Torsional Post-Buckling of a Simply Supported Thin-Walled Open-Section Beam Resting on a Two-Parameter Foundation

    Science.gov (United States)

    Rao, Ch. K.; Rao, L. B.

    2018-01-01

    The problem of the post-buckling response of a simply supported thin-walled beam subjected to an axial compressive load and supported by the Winkler-Pasternak foundation is studied in this paper. The strains are assumed to be small and elastic. The shear deformations and the in-plane cross-sectional deformations are assumed to be negligible. The post-buckling paths of the simply supported beam are determined for different values of the Winkler and Pasternak stiffness parameters. Bifurcation points are found.

  14. CT perfusion for determination of pharmacologically mediated blood flow changes in an animal tumor model.

    Science.gov (United States)

    Hakimé, Antoine; Peddi, Himaja; Hines-Peralta, Andrew U; Wilcox, Carol J; Kruskal, Jonathan; Lin, Shezhang; de Baere, Thierry; Raptopoulos, Vassilios D; Goldberg, S Nahum

    2007-06-01

    To prospectively compare single- and multisection computed tomographic (CT) perfusion for tumor blood flow determination in an animal model. All animal protocols and experiments were approved by the institutional animal care and use committee before the study was initiated. R3230 mammary adenocarcinoma was implanted in 11 rats. Tumors (18-20 mm) were scanned with dynamic 16-section CT at baseline and after administration of arsenic trioxide, which is known to cause acute reduction in blood flow. The concentration of arsenic was titrated (0-6 mg of arsenic per kilogram of body weight) to achieve a defined blood flow reduction (0%-75%) from baseline levels at 60 minutes, as determined with correlative laser Doppler flowmetry. The mean blood flow was calculated for each of four 5-mm sections that covered the entire tumor, as well as for the entire tumor after multiple sections were processed. Measurements obtained with both methods were correlated with laser Doppler flowmetry measurements. Interobserver agreement was determined for two blinded radiologists, who calculated the percentage of blood flow reduction for the "most representative" single sections at baseline and after arsenic administration. These results were compared with the interobserver variability of the same radiologists obtained by summing blood flow changes for the entire tumor volume. Overall correlations for acute blood flow reduction were demonstrated between laser Doppler flowmetry and the two CT perfusion approaches (single-section CT, r=0.85 and r(2)=0.73; multisection CT, r=0.93 and r(2)=0.87; pooled data, P=.01). CT perfusion disclosed marked heterogeneity of blood flow, with variations of 36% +/- 13 between adjacent 5-mm sections. Given these marked differences, interobserver agreement was much lower for single-section CT (standard deviation, 0.22) than for multisection CT (standard deviation, 0.10; P=.01). Multisection CT perfusion techniques may provide an accurate and more reproducible

  15. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H

    2015-01-01

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology

  16. SU-F-207-06: CT-Based Assessment of Tumor Volume in Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Qayyum, F; Armato, S; Straus, C; Husain, A; Vigneswaran, W; Kindler, H [The University of Chicago, Chicago, IL (United States)

    2015-06-15

    Purpose: To determine the potential utility of computed tomography (CT) scans in the assessment of physical tumor bulk in malignant pleural mesothelioma patients. Methods: Twenty-eight patients with malignant pleural mesothelioma were used for this study. A CT scan was acquired for each patient prior to surgical resection of the tumor (median time between scan and surgery: 27 days). After surgery, the ex-vivo tumor volume was measured by a pathologist using a water displacement method. Separately, a radiologist identified and outlined the tumor boundary on each CT section that demonstrated tumor. These outlines then were analyzed to determine the total volume of disease present, the number of sections with outlines, and the mean volume of disease per outlined section. Subsets of the initial patient cohort were defined based on these parameters, i.e. cases with at least 30 sections of disease with a mean disease volume of at least 3mL per section. For each subset, the R- squared correlation between CT-based tumor volume and physical ex-vivo tumor volume was calculated. Results: The full cohort of 28 patients yielded a modest correlation between CT-based tumor volume and the ex-vivo tumor volume with an R-squared value of 0.66. In general, as the mean tumor volume per section increased, the correlation of CT-based volume with the physical tumor volume improved substantially. For example, when cases with at least 40 CT sections presenting a mean of at least 2mL of disease per section were evaluated (n=20) the R-squared correlation increased to 0.79. Conclusion: While image-based volumetry for mesothelioma may not generally capture physical tumor volume as accurately as one might expect, there exists a set of conditions in which CT-based volume is highly correlated with the physical tumor volume. SGA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology.

  17. Comparison of drug distribution images from whole-body thin tissue sections obtained using desorption electrospray ionization tandem mass spectrometry and autoradiography.

    Science.gov (United States)

    Kertesz, Vilmos; Van Berkel, Gary J; Vavrek, Marissa; Koeplinger, Kenneth A; Schneider, Bradley B; Covey, Thomas R

    2008-07-01

    Desorption electrospray ionization tandem mass spectrometry (DESI-MS/MS) and whole-body autoradiography (WBA) were used for chemical imaging of whole-body thin tissue sections of mice intravenously dosed with propranolol (7.5 mg/kg). DESI-MS/MS imaging utilized selected reaction monitoring detection performed on an AB/MDS SCIEX 4000 QTRAP mass spectrometer equipped with a prototype extended length particle discriminator interface. Propranolol images of the tissue sections using DESI-MS/MS were obtained at surface scan rates of 0.1, 0.5, 2, and 7 mm/s. Although signal decreased with increasing scan rate, useful whole-body images for propranolol were obtained from the tissues even at 7 mm/s, which required just 79 min of analysis time. Attempts to detect and image the distribution of the known propranolol metabolites were unsuccessful. Regions of the tissue sections showing the most radioactivity from WBA sections were excised and analyzed by high-performance liquid chromatography (HPLC) with radiochemical detection to determine relative levels of propranolol and metabolites present. Comparison of the DESI-MS/MS signal for propranolol and the radioactivity attributed to propranolol from WBA sections indicated nominal agreement between the two techniques for the amount of propranolol in the brain, lung, and liver. Data from the kidney showed an unexplained disparity between the two techniques. The results of this study show the feasibility of using DESI-MS/MS to obtain useful chemical images of a drug in whole-body thin tissue sections following drug administration at a pharmacologically relevant level. Further optimization to improve sensitivity and enable detection of the drug metabolites will be among the requirements necessary to move DESI-MS/MS chemical imaging forward as a practical tool in drug discovery.

  18. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  19. Efficient CT simulation of the four-field technique for conformal radiotherapy of prostate carcinoma

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Waterman, Frank M.; Croce, Raymond J.; Corn, Benjamin; Suntharalingam, Nagalingam; Curran, Walter J.

    1997-01-01

    Purpose: Conformal radiotherapy of prostate carcinoma relies on contouring of individual CT slices for target and normal tissue localization. This process can be very time consuming. In the present report, we describe a method to more efficiently localize pelvic anatomy directly from digital reconstructed radiographs (DRRs). Materials and Methods: Ten patients with prostate carcinoma underwent CT simulation (the spiral mode at 3 mm separation) for conformal four-field 'box' radiotherapy. The bulbous urethra and bladder were opacified with iodinated contrast media. On lateral and anteroposterior DRRs, the volume of interest (VOI) was restricted to 1.0-1.5 cm tissue thickness to optimize digital radiograph reconstruction of the prostate and seminal vesicles. By removing unessential voxel elements, this method provided direct visualization of those structures. For comparison, the targets of each patient were also obtained by contouring CT axial slices. Results: The method was successfully performed if the target structures were readily visualized and geometrically corresponded to those generated by contouring axial images. The targets in 9 of 10 patients were reliable representations of the CT-contoured volumes. One patient had 18 mm variation due to the lack of bladder opacification. Using VOIs to generate thin tissue DRRs, the time required for target and normal tissue localization was on the average less than 5 min. Conclusion: In CT simulation of the four-field irradiation technique for prostate carcinoma, thin-tissue DRRs allowed for efficient and accurate target localization without requiring individual axial image contouring. This method may facilitate positioning of the beam isocenter and provide reliable conformal radiotherapy

  20. The reliability of AO classification for distal radius fracture, using CT findings

    International Nuclear Information System (INIS)

    Nakanishi, Yasuaki; Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryoutarou; Ota, Hiroyoshi

    2006-01-01

    The purpose of this study was to assess the reliability of the AO (Association for the Study of Internal Fixation) classification of distal radius fracture, using plain radiographs and 2 cross-sectional computed tomographic (CT) surface images. Five observers independently classified 32 distal radius fractures into 9 groups under AO classification. We established 4 methods for observation. First, using only two-directional radiographs; second, four-directional radiographs; third, CT (axial view) with four-directional radiographs; and fourth, CT (axial and sagittal views) with four-directional radiographs. Kappa statistics were used to establish the relative level of agreement between the observers. Interobserver reliability was poor in both first and second methods in which only plain radiographs were used (κ=0.30 and 0.23, respectively). Furthermore, reliability did not increase in the third method with the addition of 1 CT surface image (κ=0.29). In the fourth method, with the addition of 2 cross-sectional CT surface images, the reliability increased to a moderate level (κ=0.44). Interobserver reliability of the AO system of the classification of distal radius fractures was observed on using 2 cross-sectional CT surface images with four-directional radiographs. (author)

  1. Normal CT anatomy of the spine

    International Nuclear Information System (INIS)

    Quiroga, O.; Matozzi, F.; Beranger, M.; Nazarian, S.; Salamon, G.; Gambarelli, J.

    1982-01-01

    To analyse the anatomo-radiological correlation of the spine and spinal cord, 22 formalized, frozen anatomical specimens corresponding to different regions of the spinal column (8 cervical, 5 dorsal, and 9 lumbar) were studied by CT scans on axial, sagittal and coronal planes and by contact radiography after they were cut into anatomical slices in order to clarify the normal CT anatomy of the spinal column. The results obtained from CT patient scans, performed exclusively on the axial plane, were compared with those obtained from the anatomical specimens (both CT and contrast radiography). High resolution CT programs were used, enabling us to obtain better individualization of the normal structures contained in the spinal column. Direct sagittal and coronal sections were performed on the specimens in order to get further anatomo-radiological information. Enhanced CT studies of the specimens were also available because of the air already present in the subarachnoid spaces. Excellent visualization was obtained of bone structures, soft tissue and the spinal cord. High CT resolution of the spine appeares to be an excellent neuroradiological procedure to study the spine and spinal cord. A metrizamide CT scan is, however, necessary when a normal unenhanced CT scan is insufficient for diagnosis and when the spinal cord is not clearly visible, as often happens at the cervical level. Clinical findings are certainly very useful to ascertain the exact CT level and to limit the radiation exposure. (orig.)

  2. T2 mapping of CT remodelling patterns in interstitial lung disease

    Energy Technology Data Exchange (ETDEWEB)

    Buzan, Maria T.A. [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Eichinger, Monika; Heussel, Claus Peter [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Kreuter, Michael; Herth, Felix J. [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Thoraxklinik at Heidelberg University Hospital, Department of Pneumology, Center for Rare and Interstitial Lung Diseases, Heidelberg (Germany); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Warth, Arne [Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); University Hospital Heidelberg, Institute for Pathology, Heidelberg (Germany); Pop, Carmen Monica [Iuliu Hatieganu University of Medicine and Pharmacy, Department of Pneumology, Cluj-Napoca (Romania); Dinkel, Julien [Thoraxklinik at Heidelberg University Hospital, Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Heidelberg (Germany); Comprehensive Pneumology Center Munich (CPC-M), German Center for Lung Research (DZL), Munich (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-11-15

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  3. T2 mapping of CT remodelling patterns in interstitial lung disease

    International Nuclear Information System (INIS)

    Buzan, Maria T.A.; Eichinger, Monika; Heussel, Claus Peter; Kreuter, Michael; Herth, Felix J.; Kauczor, Hans-Ulrich; Warth, Arne; Pop, Carmen Monica; Dinkel, Julien

    2015-01-01

    To evaluate lung T2 mapping for quantitative characterization and differentiation of ground-glass opacity (GGO), reticulation (RE) and honeycombing (HC) in usual interstitial pneumonia (UIP) and non-specific interstitial pneumonia (NSIP). Twelve patients with stable UIP or NSIP underwent thin-section multislice CT and 1.5-T MRI of the lung. A total of 188 regions were classified at CT into normal (n = 29) and pathological areas, including GGO (n = 48), RE (n = 60) and HC (n = 51) predominant lesions. Entire lung T2 maps based on multi-echo single shot TSE sequence (TE: 20, 40, 79, 140, 179 ms) were generated from each subject with breath-holds at end-expiration and ECG-triggering. The median T2 relaxation of GGO was 67 ms (range 60-72 ms). RE predominant lesions had a median relaxation of 74 ms (range 69-79 ms), while for HC pattern this was 79 ms (range 74-89 ms). The median T2 relaxation for normal lung areas was 41 ms (ranged 38-49 ms), and showed significant difference to pathological areas (p < 0.001). A statistical difference was found between the T2 relaxation of GGO, RE and HC (p < 0.05). The proposed method provides quantitative information for pattern differentiation, potentially allowing for monitoring of progression and response to treatment, in interstitial lung disease. (orig.)

  4. Thin-film electroencephalographic electrodes using multi-walled carbon nanotubes are effective for neurosurgery.

    Science.gov (United States)

    Awara, Kousuke; Kitai, Ryuhei; Isozaki, Makoto; Neishi, Hiroyuki; Kikuta, Kenichiro; Fushisato, Naoki; Kawamoto, Akira

    2014-12-15

    Intraoperative morphological and functional monitoring is essential for safe neurosurgery. Functional monitoring is based on electroencephalography (EEG), which uses silver electrodes. However, these electrodes generate metal artifacts as silver blocks X-rays, creating white radial lines on computed tomography (CT) images during surgery. Thick electrodes interfere with surgical procedures. Thus, thinner and lighter electrodes are ideal for intraoperative use. The authors developed thin brain electrodes using carbon nanotubes that were formed into thin sheets and connected to electrical wires. The nanotube sheets were soft and fitted the curve of the head very well. When attached to the head using paste, the impedance of the newly developed electrodes was 5 kΩ or lower, which was similar to that of conventional metal electrodes. These electrodes can be used in combination with intraoperative CT, magnetic resonance imaging (MRI), or cerebral angiography. Somatosensory-evoked potentials, auditory brainstem responses, and visually evoked potentials were clearly identified in ten volunteers. The electrodes, without any artifacts that distort images, did not interfere with X-rays, CT, or MR images. They also did not cause skin damage. Carbon nanotube electrodes may be ideal for neurosurgery.

  5. Reconstruction of CT images by the Bayes- back projection method

    CERN Document Server

    Haruyama, M; Takase, M; Tobita, H

    2002-01-01

    In the course of research on quantitative assay of non-destructive measurement of radioactive waste, the have developed a unique program based on the Bayesian theory for reconstruction of transmission computed tomography (TCT) image. The reconstruction of cross-section images in the CT technology usually employs the Filtered Back Projection method. The new imaging reconstruction program reported here is based on the Bayesian Back Projection method, and it has a function of iterative improvement images by every step of measurement. Namely, this method has the capability of prompt display of a cross-section image corresponding to each angled projection data from every measurement. Hence, it is possible to observe an improved cross-section view by reflecting each projection data in almost real time. From the basic theory of Baysian Back Projection method, it can be not only applied to CT types of 1st, 2nd, and 3rd generation. This reported deals with a reconstruction program of cross-section images in the CT of ...

  6. Evaluation of pressed powders and thin section standards for multi-elemental analysis by conventional and micro-PIXE analysis

    International Nuclear Information System (INIS)

    Homma-Takeda, Shino; Iso, Hiroyuki; Ito, Masaki

    2010-01-01

    For multi-elemental analysis, various standards are used to quantify the elements consists of environmental and biological samples. In this paper two different configuration standards, pressed powders and thin section standards, were assessed for their purpose as standards by conventional and micro-PIXE analysis. Homogeneity of manganese, iron, zinc (Zn), copper and yttrium added to pressed powder standard materials were validated and the relative standard deviation (RSD) of the X-ray intensity of the standards was 2 area and the metal concentration was acceptable. (author)

  7. Reconstruction of MRI/CT compatible ring and tandem applicators in CT or MRI images used for treatment planning in brachytherapy

    International Nuclear Information System (INIS)

    Surendran, N.; Kim, Hayeon; Beriwal, Sushil; Saiful Huq, M.

    2008-01-01

    Brachytherapy (BT) plays a crucial role in the management of invasive cervix cancer from stage I to IV. Intracavitary techniques are based on afterloading devices, with different types of applicators. CT and/or MRI compatible applicators allow a sectional image based approach with a better assessment of gross tumour volume (GTV) and definition and delineation of target volume (CTV) compared to traditional approaches. To evaluate reconstruction of MRI/CT compatible ring and tandem applicators in 3D CT or MRI images used for treatment planning in Brachytherapy

  8. Diagnostic accuracy of computed tomography and histopathology in the diagnosis of usual interstitial pneumonia

    International Nuclear Information System (INIS)

    Aaloekken, Trond Mogens; Mynarek, Georg; Kolbenstvedt, Alf; Naalsund, Anne; Elnaes Berstad, Audun; Solberg, Steinar; Stroem, Erik H.; Scott, Helge; Soeyseth, Vidar

    2012-01-01

    Background: The relative clinical benefit of histopathology and computed tomography (CT) in patients with idiopathic interstitial pneumonia (IIP) is under debate. Purpose: To analyze thin-section CT features and histopathologic findings in patients with usual interstitial pneumonia (UIP) in the clinical context of idiopathic pulmonary fibrosis (IPF), and to evaluate and compare diagnostic accuracy of the two methods among patients with an appropriate spectrum of IIP. Material and Methods: The study included 91 patients (49 men; mean age 53.2 years; median follow-up 7.2 years) with clinically suspected interstitial lung disease. All underwent surgical lung biopsy and thin-section CT. Two independent readers retrospectively assessed the CT images for the extent and pattern of abnormality and made a first-choice diagnosis. Two pathologists retrospectively assessed the histopathologic slides. In 64 patients with IIP, a retrospective composite reference standard identified 41 patients with UIP. CT characteristics of UIP and IIPs other than UIP were compared with univariate and multivariate analyses. Results: There was good agreement between the readers for the correct first-choice CT diagnosis of UIP (κ = 0.79). The sensitivity, specificity, and positive predictive value of the CT diagnosis of UIP were 63%, 96%, and 96%, respectively. The sensitivity, specificity, and positive predictive value of the histological diagnosis of UIP were 73%, 74%, and 83%, respectively. The CT feature that best differentiated UIP from IIPs other than UIP was the extent of reticular pattern (odds ratio, 5.1). Conclusion: Surgical lung biopsy may not be warranted in patients with thin-section CT diagnosis of UIP

  9. Diagnostic accuracy of computed tomography and histopathology in the diagnosis of usual interstitial pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Aaloekken, Trond Mogens; Mynarek, Georg; Kolbenstvedt, Alf (Dept. of Radiology, Oslo Univ. Hospital Rikshospitalet, Oslo (Norway)), Email: trond.mogens.aalokken@rikshospitalet.no; Naalsund, Anne (Dept. of Pulmonology, Oslo Univ. Hospital Rikshospitalet (Norway)); Elnaes Berstad, Audun (Dept. of Radiology, Oslo Univ. Hospital Rikshospitalet, Oslo (Norway); Univ. of Oslo (Norway)); Solberg, Steinar (Dept. of Thoracic Surgery, Oslo Univ. Hospital Rikshospitalet (Norway)); Stroem, Erik H.; Scott, Helge (Dept. of Pathology, Oslo Univ. Hospital Rikshospitalet (Norway)); Soeyseth, Vidar (Univ. of Oslo (Norway); Depts. of Pulmonology, Akershus Univ. Hospital, Loerenskog (Norway))

    2012-04-15

    Background: The relative clinical benefit of histopathology and computed tomography (CT) in patients with idiopathic interstitial pneumonia (IIP) is under debate. Purpose: To analyze thin-section CT features and histopathologic findings in patients with usual interstitial pneumonia (UIP) in the clinical context of idiopathic pulmonary fibrosis (IPF), and to evaluate and compare diagnostic accuracy of the two methods among patients with an appropriate spectrum of IIP. Material and Methods: The study included 91 patients (49 men; mean age 53.2 years; median follow-up 7.2 years) with clinically suspected interstitial lung disease. All underwent surgical lung biopsy and thin-section CT. Two independent readers retrospectively assessed the CT images for the extent and pattern of abnormality and made a first-choice diagnosis. Two pathologists retrospectively assessed the histopathologic slides. In 64 patients with IIP, a retrospective composite reference standard identified 41 patients with UIP. CT characteristics of UIP and IIPs other than UIP were compared with univariate and multivariate analyses. Results: There was good agreement between the readers for the correct first-choice CT diagnosis of UIP (kappa = 0.79). The sensitivity, specificity, and positive predictive value of the CT diagnosis of UIP were 63%, 96%, and 96%, respectively. The sensitivity, specificity, and positive predictive value of the histological diagnosis of UIP were 73%, 74%, and 83%, respectively. The CT feature that best differentiated UIP from IIPs other than UIP was the extent of reticular pattern (odds ratio, 5.1). Conclusion: Surgical lung biopsy may not be warranted in patients with thin-section CT diagnosis of UIP

  10. Model based rib-cage unfolding for trauma CT

    Science.gov (United States)

    von Berg, Jens; Klinder, Tobias; Lorenz, Cristian

    2018-03-01

    A CT rib-cage unfolding method is proposed that does not require to determine rib centerlines but determines the visceral cavity surface by model base segmentation. Image intensities are sampled across this surface that is flattened using a model based 3D thin-plate-spline registration. An average rib centerline model projected onto this surface serves as a reference system for registration. The flattening registration is designed so that ribs similar to the centerline model are mapped onto parallel lines preserving their relative length. Ribs deviating from this model appear deviating from straight parallel ribs in the unfolded view, accordingly. As the mapping is continuous also the details in intercostal space and those adjacent to the ribs are rendered well. The most beneficial application area is Trauma CT where a fast detection of rib fractures is a crucial task. Specifically in trauma, automatic rib centerline detection may not be guaranteed due to fractures and dislocations. The application by visual assessment on the large public LIDC data base of lung CT proved general feasibility of this early work.

  11. A novel APD-based detector module for multi-modality PET/SPECT/CT scanners

    International Nuclear Information System (INIS)

    Saoudi, A.; Lecomte, R.

    1999-01-01

    The lack of anatomical information in SPECT and PET images is one of the major factors limiting the ability to localize and accurately quantify radionuclide uptake in small regions of interest. This problem could be resolved by using multi-modality scanners having the capability to acquire anatomical and functional images simultaneously. The feasibility of a novel detector suitable for measuring high-energy annihilation radiation in PET, medium-energy γ-rays in SPECT and low-energy X-rays in transmission CT is demonstrated and its performance is evaluated for potential use in multi-modality PET/SPECT/CT imaging. The proposed detector consists of a thin CsI(Tl) scintillator sitting on top of a deep GSO/LSO pair read out by an avalanche photodiode. The GSO/LOS pair provides depth-of-interaction information for 511 keV detection in PET, while the thin CsI(Tl) that is essentially transparent to annihilation radiation is used for detecting lower energy X- and γ-rays. The detector performance is compared to that of an LSO/YSO phoswich. Although the implementation of the proposed GSO/LSO/CsI(Tl) detector raises special problems that increase complexity, it generally outperforms the LSO/YSO phoswich for simultaneous PET, SPECT and CT imaging

  12. Study on Mechanical Behavior of Thin-walled Member during Precision Straightening Process

    Directory of Open Access Journals (Sweden)

    Ben Guan

    2014-09-01

    Full Text Available This paper introduces the mechanical behavior of precise straightening thin-walled members systematically. As a result of its cross section characteristics of the thin-walled members, traditional straightening theory does not work well in the straightening process of this kind of metal bar stock. Considering the stress evolvement of section during the straightening process, a model was built to analysis the straightening process like thin-walled member with great section height. By making a thorough analysis of the straightening process, the section deformation law and the relationship between sectional distortion and straightening parameters has been mastered. An analytical model was built for macroscopic energetics parameters of the straightening process and the parameters was optimized based on this model. Then loading mode of thin-walled member straightening was discussed.

  13. Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)]. E-mail: rcury@partners.org; Ferencik, Maros [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Achenbach, Stephan [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Department of Internal Medicine II, University of Erlangen (Germany); Pomerantsev, Eugene [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Moselewski, Fabian [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2006-03-15

    Background: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. Methods: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study, which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. Results: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 {+-} 23% versus 64 {+-} 29%; r {sup 2} = 0.83, p < 0.001 and MIP versus QCA: 64 {+-} 22% versus 64 {+-} 29%; r {sup 2} = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 {+-} 12% using CS-MPR and a minimally positive bias of 0.6 {+-} 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, >70%) the agreement between both CS-MPR and MIP was high when compared to QCA ({kappa} = 0.74 and 0.71, respectively). Conclusion: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both

  14. Assessment of tumor heterogeneity by CT texture analysis: Can the largest cross-sectional area be used as an alternative to whole tumor analysis?

    International Nuclear Information System (INIS)

    Ng, Francesca; Kozarski, Robert; Ganeshan, Balaji; Goh, Vicky

    2013-01-01

    Objective: To determine if there is a difference between contrast enhanced CT texture features from the largest cross-sectional area versus the whole tumor, and its effect on clinical outcome prediction. Methods: Entropy (E) and uniformity (U) were derived for different filter values (1.0–2.5: fine to coarse textures) for the largest primary tumor cross-sectional area and the whole tumor of the staging contrast enhanced CT in 55 patients with primary colorectal cancer. Parameters were compared using non-parametric Wilcoxon test. Kaplan–Meier analysis was performed to determine the relationship between CT texture and 5-year overall survival. Results: E was higher and U lower for the whole tumor indicating greater heterogeneity at all filter levels (1.0–2.5): median (range) for E and U for whole tumor versus largest cross-sectional area of 7.89 (7.43–8.31) versus 7.62 (6.94–8.08) and 0.005 (0.004–0.01) versus 0.006 (0.005–0.01) for filter 1.0; 7.88 (7.22–8.48) versus 7.54 (6.86–8.1) and 0.005 (0.003–0.01) versus 0.007 (0.004–0.01) for filter 1.5; 7.88 (7.17–8.54) versus 7.48 (5.84–8.25) and 0.005 (0.003–0.01) versus 0.007 (0.004–0.02) for filter 2.0; and 7.83 (7.03–8.57) versus 7.42 (5.19–8.26) and 0.005 (0.003–0.01) versus 0.006 (0.004–0.03) for filter 2.5 respectively (p ≤ 0.001). Kaplan–Meier analysis demonstrated better separation of E and U for whole tumor analysis for 5-year overall survival. Conclusion: Whole tumor analysis appears more representative of tumor heterogeneity

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... of the body, in a shorter period of time. Modern CT scanners are so fast that they can scan through large sections of the body in just a few seconds. Such speed is beneficial for ...

  16. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  17. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  18. The relationship between image quality and CT dose index of multi-slice low-dose chest CT

    International Nuclear Information System (INIS)

    Zhu Xiaohua; Shao Jiang; Shi Jingyun; You Zhengqian; Li Shijun; Xue Yongming

    2003-01-01

    Objective: To explore the rationality and possibility of multi-slice low-dose CT scan in the examination of the chest. Methods: (1) X-ray dose index measurement: 120 kV tube voltage, 0.75 s rotation, 8 mm and 3 mm slice thickness, and the tube current setting of 115.0, 40.0, 25.0, and 7.5 mAs were employed in every section. The X-ray radiation dose was measured and compared statistically. (2) phantom measurement of homogeneity and noise: The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm sections, and every slice was scanned using tube current of 115.0, 40.0, 25.0, and 7.5 mAs. Five same regions of interest were measured on every image. The homogeneity and noise level of CT were appraised. (3) The multi-slice low-dose CT in patients: 30 patients with mass and 30 with patch shadow in the lung were selected randomly. The technical parameters were 120 kV, 0.75 s, 8 mm and 3 mm slice thickness. 115.0, 40.0, 25.0, 15.0, and 7.5 mAs tube current were employed in each same slice. Otherwise, 15 cases with helical scan were examined using 190, 150, 40, 25, and 15 mAs tube current. The reconstruction images of MIP, MPR, CVR, HRCT, 3D, CT virtual endoscopy, and variety of interval reconstruction were compared. (4) Evaluation of image quality: CT images were evaluated by four doctors using single-blind method, and 3 degrees including normal image, image with few artifact, and image with excessive artifact, were employed and analyzed statistically. Results: (1) The CT dose index with 115.0 mAs tube current exceeded those of 40.0, 25.0, and 7.5 mAs by about 60%, 70%, and 85%, respectively. (2) The phantom measurement showed that the lower of CT dose the lower of homogeneity, the lower of CT dose the higher of noise level. (3) Result of image quality evaluation: The percentage of the normal image had no significant difference between 8 and 3 mm in 115, 40, and 25 mAs (P>0.05). Conclusion: Multi-slice low-dose chest CT technology may protect the patients and guarantee the

  19. Paediatric CT scan usage and referrals of children to computed tomography in Germany-a cross-sectional survey of medical practice and awareness of radiation related health risks among physicians

    Directory of Open Access Journals (Sweden)

    Merzenich Hiltrud

    2012-02-01

    Full Text Available Abstract Background Computed tomography (CT is a major source of ionizing radiation exposure in medical diagnostic. Compared to adults, children are supposed to be more susceptible to health risks related to radiation. The purpose of a cross-sectional survey among office-based physicians in Germany was the assessment of medical practice in paediatric CT referrals and to investigate physicians' knowledge of radiation doses and potential health risks of radiation exposure from CT in children. Methods A standardized questionnaire was distributed to all paediatricians and surgeons in two defined study areas. Furthermore, the study population included a random sample of general practitioners in the two areas. The questionnaire covered the frequency of referrals for paediatric CT examinations, the medical diagnoses leading to paediatric CT referrals, physicians' knowledge of radiation doses and potential health risks of radiation exposure from CT in children. Results A total of 295 (36.4% physicians responded. 59% of the doctors had not referred a child to CT in the past year, and approximately 30% referred only 1-5 children annually. The most frequent indications for a CT examination in children were trauma or a suspected cancer. 42% of the referrals were related to minor diagnoses or unspecific symptoms. The participants underestimated the radiation exposure due to CT and they overestimated the radiation exposure due to conventional X-ray examinations. Conclusions In Germany, the frequency of referrals of children to computed tomography is moderate. The knowledge on the risks from radiation exposure among office-based physicians in our sample varied, but there was a tendency to underestimate potential CT risks. Advanced radiological training might lead to considerable amendments in terms of knowledge and practice of CT referral.

  20. Pulmonary infections after kidney transplantation: analysis of CT findings

    International Nuclear Information System (INIS)

    Xue Feng; Liu Shiyuan; Li Li; Gao Xin; Liu Kai; Li Huimin

    2009-01-01

    Objective: To review the CT findings in patients with pulmonary infection after kidney transplantation and to determine the characteristic features in different infections. Methods: The medical records were reviewed in 446 patients with pulmonary infection after kidney transplantation and 121 patients who had pulmonary thin-section CT were included in this study. The pattern and distribution of the pulmonary abnormalities were interpreted independently by two thoracic radiologists. Statistical analysis was performed using the χ 2 test and the Fisher's exact test. Results: (1) Time course: 65 (14.6%) patients initially had pulmonary infection in the first 30 days, 147 (32.9%) between 1 and 3 months, 91 (20.4%) between 3 and 6 months, 23 (5.2%) between 6 and 12 months, 120 (26.9%)after 12 months of transplantation. In the first month after procedure, bacterial infection (4/5,80.0%) was the most common infection, bacterial (34/41,82.9%), mixed (19/41,46.3%) and vires infections (11/41,26.8%) were seen commonly 1 to 6 months following transplant, the incidence of fungal (14/38, 36.8%) and mycobacterial (5/38,13.2%) infections was increased after 12 months of transplantation. (2)Pathogens: Bacterial (34,28%) and mixed infections (34,28%) were the most common, followed by fungus infection (9, 7%), TB(7,6%)and cytomegalovims (5,4%). (3)CT findings: Ground-glass attenuations (69,57.0%) was the most common findings of pneumonia, followed by reticular or linear opacities (68,56.2%), nodules (66,54.5%), pleural thickening (41,33.9%), consolidations (31,25.6%), tree-in-bud patterns (24, 19.8%), pleural effusion (22,18.2%), and bronchovascular bundle thickening (16,13.2%). Ground-glass attenuation was commonly seen in cytomegalovims pneumonia (4,80.0%), and nodule was commonly observed in bacterial infection (23,67.6%), tree-in-bud pattern was the most common finding in pulmonary tuberculosis(4, P=0.049). There were no statistically significant differences in the prevalence of

  1. An experimental study for qualitatively diagnosing stapes lesions by helical 3-dimensional CT

    International Nuclear Information System (INIS)

    Kawaue, Akifumi; Kuki, Kiyonori; Yamanaka, Noboru; Nishimura, Michihiko

    2001-01-01

    To evaluate qualitative diagnosis of stapes lesions by 3-dimensional computed tomography (3D-CT) combined with superselective image processing (3D-SS) of stapes, we studied helical 3D-CT on a phantom model of the temporal bone. Two stapes models were used-1 made from the bone filler, Celatite, consistent in bone density but changing in cross sectional area, and the other made from an apacerum rod used in quantitative computed tomography (QCT), consistent in cross sectional area but changing in bone density. These stapes models were put into a skull phantom and analyzed by helical 3D-CT. The influence of the tympanic cavity conditions on CT images of stapes was evaluated by filling the phantom model with Vaseline following 3D selective reconstruction. In all stapes models, lowering the lower CT window width threshold resulted in an enlarged cross-sectional area of the model. The higher the bone density, the lower the increase in cross-sectional area in the image. The stapes model with lower density had greater influence on the imaging by tympanic cavity conditions and was likely to be misdiagnosed as showing higher bone density. Based on the experimental study, 3D-SS by helical 3D-CT appears to be a useful measure for qualitatively diagnosing stapes lesions. (author)

  2. SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

    International Nuclear Information System (INIS)

    Lin, T; Hamacher, K

    2016-01-01

    Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

  3. SU-F-I-59: Quality Assurance Phantom for PET/CT Alignment and Attenuation Correction

    Energy Technology Data Exchange (ETDEWEB)

    Lin, T; Hamacher, K [Columbia University Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: This study utilizes a commercial PET/CT phantom to investigate two specific properties of a PET/CT system: the alignment accuracy of PET images with those from CT used for attenuation correction and the accuracy of this correction in PET images. Methods: A commercial PET/CT phantom consisting of three aluminum rods, two long central cylinders containing uniform activity, and attenuating materials such as air, water, bone and iodine contrast was scanned using a standard PET/CT protocol. Images reconstructed with 2 mm slice thickness and a 512 by 512 matrix were obtained. The center of each aluminum rod in the PET and CT images was compared to evaluate alignment accuracy. ROIs were drawn on transaxial images of the central rods at each section of attenuating material to determine the corrected activity (in BQML). BQML values were graphed as a function of slice number to provide a visual representation of the attenuation-correction throughout the whole phantom. Results: Alignment accuracy is high between the PET and CT images. The maximum deviation between the two in the axial plane is less than 1.5 mm, which is less than the width of a single pixel. BQML values measured along different sections of the large central rods are similar among the different attenuating materials except iodine contrast. Deviation of BQML values in the air and bone sections from the water section is less than 1%. Conclusion: Accurate alignment of PET and CT images is critical to ensure proper calculation and application of CT-based attenuation correction. This study presents a simple and quick method to evaluate the two with a single acquisition. As the phantom also includes spheres of increasing diameter, this could serve as a straightforward means to annually evaluate the status of a modern PET/CT system.

  4. Visualization of Individual Images in Patterned Organic-Inorganic Multilayers Using GISAXS-CT.

    Science.gov (United States)

    Ogawa, Hiroki; Nishikawa, Yukihiro; Takenaka, Mikihito; Fujiwara, Akihiko; Nakanishi, Yohei; Tsujii, Yoshinobu; Takata, Masaki; Kanaya, Toshiji

    2017-05-16

    Using grazing-incidence small-angle scattering (GISAXS) with computed tomography (CT), we have individually reconstructed the spatial distribution of a thin gold (Au) layer buried under a thin poly(styrene-b-2-vinylpyridine) (PS-b-P2VP) layer. Owing to the difference between total reflection angles of Au and PS-b-P2VP, the scattering profiles for Au nanoparticles and self-assembled nanostructures of PS-b-P2VP could be independently obtained by changing the X-ray angle of incidence. Reconstruction of scattering profiles allows one to separately characterize spatial distributions in Au and PS-b-P2VP nanostructures.

  5. Thin-section microscopy of decayed crystalline marble from the garden sculptures of Schoenbrunn Palace in Vienna

    International Nuclear Information System (INIS)

    Weber, J.; Beseler, S.; Sterflinger, K.

    2007-01-01

    Sterzing marble, a crystalline white marble used in the late-Baroque garden sculptures of Schoenbrunn Palace in Vienna, was studied by means of thin-section and scanning electron microscopy in order to obtain a better understanding of its surface decay caused by atmospheric weathering. Following the classification of distinct phenomena of deterioration by visual on-site inspection, the microstructural features including surface erosion, micro-cracking, soiling, black crust formation, and microbiological infestation are exemplified by microscopical images and are briefly discussed. The results proved useful for evaluating and understanding the various types of marble decay for creating a safer basis for establishing the procedural principles aimed at conservation and maintenance of the sculptures

  6. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  7. Triple-layer appearance of Brodmann area 4 at thin-section double inversion-recovery MR imaging.

    Science.gov (United States)

    Kim, Eung Yeop; Kim, Dong-Hyun; Chang, Jong-Hee; Yoo, Eunhye; Lee, Jae-Wook; Park, Hae-Jeong

    2009-02-01

    To investigate whether thin-section axial double inversion-recovery (DIR) brain magnetic resonance (MR) imaging at 3.0 T can help distinguish the primary motor cortex (PMC), or Brodmann area 4, from other selected cortical regions, including the primary sensory cortex (PSC), or Brodmann areas 1-3, on the basis of the presence of a "triple-layer" appearance. This prospective study was approved by the institutional review board; informed consent was obtained from patients. This study included 191 patients (94 female, age range, 5-80 years; 97 male, age range, 5-76 years) with normal findings at 3.0-T MR imaging. The presence or absence of a triple-layer appearance within selected cortical regions on DIR images was graded independently by two neuroradiologists as definitely present (grade 2), probably present (grade 1), or definitely absent (grade 0). Ten additional patients with tumors underwent DIR imaging and intraoperative cortical mapping for further validation of the PMC. A myelin-stained brain specimen image in a patient not imaged with DIR was correlated with a representative set of DIR images. A triple-layer appearance was found in the PMC bilaterally in 184 of 191 patients; grade 0 was assigned in only seven patients, who were all younger than 10 years. Grades were significantly lower in patients younger than 10 years than in others (P .0018). Interobserver agreement was excellent (weighted kappa = 0.843). The PMC determined on DIR images was confirmed with cortical mapping in all 10 patients with tumors. Triple-layer appearance was not present in the other cortical regions examined, including the PSC (P < .01). The triple-layer appearance on DIR images corresponded to the myelin band within the PMC present on the myelin-stained specimen image. A triple-layer appearance was found in the PMC at thin-section 3.0-T DIR imaging but not in other examined brain regions and therefore might be useful as an adjunct sign for identification of motor regions.

  8. Value of computed tomography pelvimetry in patients with a previous cesarean section

    International Nuclear Information System (INIS)

    Yamani, Tarik Y.; Rouzi, Abdulrahim A.

    1998-01-01

    A case-control study was conducted at the Department of Obstetrics and Gynaecology, King Abdulaziz University Hospital, Jeddah, Saudi Arabia to determine the value of computed tomography pelivimetry in patients with a previous cesarean section. Between January 1993 and December 1995, 219 pregnant women with one previous cesarean had antenatal CT pelvimetry for assessment of the pelvis. One hundred and nineteen women did not have CT pelvimetry and served as control. Fifty-one women (51%) in the CT pelvimetry group were delivered by cesarean section. Twenty-three women (23%) underwent elective cesarean section for contracted pelvis based upon the findings of CT pelvimetry and 28 women (28%) underwent emergency cesarean section after trial of labor. In the group who did not have CT pelvimetry, 26 women (21.8%) underwent emergency cesarean section. This was a statistically significant difference (P=0.02). There were no statistically significant differences in birthweight and Apgar scores either group. There was no prenatal or maternal mortality in this study. Computed tomography pelvimetry increased the rate of cesarean delivery without any benefit in the immediate delivery outcomes. Therefore, the practice of documenting the adequacy of the pelvis by CT pelvimetry before vaginal birth after cesarean should be abandoned. (author)

  9. Endometriosis of the rectum: CT findings

    International Nuclear Information System (INIS)

    Guo Yan; Huang Zhaomin; Liu Mingjuan; Zhong Juemin

    2004-01-01

    Objective: To investigate the CT manifestations of recto-endometriosis. Methods: Three pathologically proved cases of recto-endometriosis were reported, the CT features and clinical manifestations were investigated retrospectively with review of literatures. Results: The patients were all menstruating females (28, 34, and 45 years old, respectively), and anal pain emerged during menses in one case. Rectal examination revealed stiff immobile mass along the rectal wall in all three cases. All the cases showed solid masses on CT scan with moderate enhancement after contrast administration. Two of them confined to the rectal walls, another involved the rectum and peri-rectal aspect. One case was misdiagnosed as well-differentiated adenocarcinoma of rectum in frozen section by biopsy specimen. Conclusion: A solid mass was always found in recto-endometriosis. No characteristic CT feature was manifested. Attention should be paid to the differentiation from rectal tumors when making the diagnosis

  10. The impact of voxel size-based inaccuracies on the mechanical behavior of thin bone structures.

    Science.gov (United States)

    Maloul, Asmaa; Fialkov, Jeffrey; Whyne, Cari

    2011-03-01

    Computed tomography (CT)-based measures of skeletal geometry and material properties have been widely used to develop finite element (FE) models of bony structures. However, in the case of thin bone structures, the ability to develop FE models with accurate geometry derived from clinical CT data presents a challenge due to the thinness of the bone and the limited resolution of the imaging devices. The purpose of this study was to quantify the impact of voxel size on the thickness and intensity values of thin bone structure measurements and to assess the effect of voxel size on strains through FE modeling. Cortical bone thickness and material properties in five thin bone specimens were quantified at voxel sizes ranging from 16.4 to 488 μm. The measurements derived from large voxel size scans showed large increases in cortical thickness (61.9-252.2%) and large decreases in scan intensity (12.9-49.5%). Maximum principal strains from FE models generated using scans at 488 μm were decreased as compared to strains generated at 16.4 μm voxel size (8.6-64.2%). A higher level of significance was found in comparing intensity (p = 0.0001) vs. thickness (p = 0.005) to strain measurements. These findings have implications in developing methods to generate accurate FE models to predict the biomechanical behavior of thin bone structures.

  11. Skeletal Class III malocclusion with thin symphyseal bone: a case report.

    Science.gov (United States)

    Hikida, Eriko; Tanikawa, Chihiro

    2012-11-01

    To describe the management of a severe skeletal Class III patient with thin symphyseal bone and alveolar bone covering the mandibular incisors. A 24 year-old female presented with a skeletal Class III malocclusion characterised by thin alveolar bone in a mildly crowded, mandibular incisor region. Computerised tomography (CT) assisted in the determination of possible tooth movement within the anterior mandibular alveolar bone. The finalised treatment plan aimed to align the maxillary and mandibular dental arches following the extraction of the maxillary right first premolar and the mandibular right permanent lateral incisor. The surgical repositioning of the maxilla and mandible with a LeFort I osteotomy and a bilateral sagittal split osteotomy (BSSO) would follow. After treatment, an acceptable facial profile and a solid intercuspation of the teeth were obtained. Significant root resorption was not observed. The occlusion remained stable with normal overjet and overbite after two years of retention. CT examination provided an assessment of the three-dimensional morphological characteristics of anterior alveolar bone which enabled an evaluation of possible tooth movement.

  12. Three interesting cases of gyral infarction as detected by CT in the vicinity of the central sulcus

    International Nuclear Information System (INIS)

    Tokiguchi, Susumu; Kurashima, Akihiko; Tsuchiya, Toshiaki; Ito, Jusuke

    1986-01-01

    In most cases of senile brain, the arrangement of the cerebral sulci and gyri of the superior surface of the hemisphere is well demonstrated by thin-sectioned CT. In these cases, it is not very difficult to identify the cortical gyri anatomically. We experienced three interesting cases with a small gyral infarction in the vicinity of the central sulcus (Roland). The lesions were detected and their anatomical localizations were precisely identified by CT, and they correlated well with their clinical findings. In Case 1, who suddenly developed clumsiness of the left hand, neurological findings were confined to her left hand, where a marked impairment of the combined sensation and position sense was found. However, there was no weakness or impaired vibration sense or disturbed superficial sensation. Since vibratory appreciation is seldom disturbed by lesions above the level of the thalamus, and since the combined sensation and joint sense were selectively impaired in this case, a lesion in the right parietal lobe was suggested. CT scan revealed a small gyral infarction which was strictly confined to the right postcentral gyrus. Case 2, developed weakness of the left hand. He could not extend the wrist against gravity, but dorsiflexion of the wrist could be elicited by grasping. Weakness was confined to his left hand, and there was no sensory disturbance. Neurological findings suggested a small cortical infraction in the right precentral gyrus. CT showed a small lesion just under the right precentral gyrus, where the cortical representation of the hand was thought to be arranged. In Case 3, who developed an adversive seizure, CT clearly demonstrated a lesion in the contralateral premotor area. Our method of the anatomical identification of the sulci and the gyri of the superior surface of the cerebral hemisphere was described. (author)

  13. New perspectives on CT in peritoneal carcinomatosis and other peritoneal malignancies

    International Nuclear Information System (INIS)

    Walkey, M.M.; Friedman, A.C.; Radecki, P.D.; Sohotra, P.

    1987-01-01

    Seventy-three abdominopelvic CT studies in 60 patients with peritoneal tumor spread were reviewed. Ascites was the most common CT finding (74%), with loculation occurring in half. A new finding, loculation of fluid out of the cul-de-sac, is described. Parietal peritoneal thickening and enhancement was visible as a thin enhancing line along the peritoneal surface in 62% of studies. This represents the CT correlate of miliary seeding that has progressed to the point of confluence. Tumor involvement of the omentum was manifest as marbled fat, enhancing nodules, or an omental cake. Mucin-producing implants and their progression to pseydomyxoma peritonei were observed. In 26 patients without a known malignancy, a specific diagnosis was possible in 13 (50%) with identification of a primary tumor. Of 13 patients with no visible primary, six (46%) had ovarian peritoneal carcinomatosis with normal-sized ovaries or minimal adnexal pathology

  14. Persistent candidemia in major burn patients: radiologic findings of the thorax

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eil Seong; Lee, Kwan Seop; Kang, Ik Won [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-04-01

    To describe radiologic findings of burn-associated persistent candidemia of the thorax. This study included 42 patients with major burns in whom blood culture had shown the presence for more than 24 hours of persistent candidemia. The duration of positive culture for candidiasis ranged from two to 67 days(mean, 15 days). Radiographic(n=42) and thin-section CT findings(n=13) were retrospectively analyzed. The onset, pattern, size, distribution and persistence of parenchymal abnormalities as well as the presence or absence of pleural effusions, mediastinal lymphadenopathy and cardiomegaly were assessed. On chest radiographs, positive findings were noticed in 61.9%(26/42) and on thin-section CT, in 76.9%(10/13). The most frequent radiographic finding was pulmonary nodule(s), observed in 14 patients(33.3%); in 13, these were bilateral. Bronchovascular bundle thickening(n=6, 14.3%), consolidation(n=4, 9.5%), cardiomegaly(n=6, 14.3%) and pleural effusion(n=4, 9.5%) were also observed. Those lesions appeared eight to 129 days(mean, 33 days) after the burn. Radiographic abnormalities persisted for seven to 115(mean, 35) days, regardless of the treatment. Thin-section CT showed parenchymal abnormalities in 10/13 patients(76.9%) and subpleural nodules of less than 1cm in diameter and without halo in all patients. Cardiomegaly, pleural effusion and mediastinal adenopathy were observed on CT in 5(38.5%), 4(30.8%) and 2(15.4%) of the 13 patients, respectively. In a high proportion of patients with burn-associated candidemia, chest radiograph and thin-section CT findings were positive. The most frequent radiographic parenchymal abnormality was multiple bilateral nodules.

  15. Persistent candidemia in major burn patients: radiologic findings of the thorax

    International Nuclear Information System (INIS)

    Lee, Eil Seong; Lee, Kwan Seop; Kang, Ik Won

    1997-01-01

    To describe radiologic findings of burn-associated persistent candidemia of the thorax. This study included 42 patients with major burns in whom blood culture had shown the presence for more than 24 hours of persistent candidemia. The duration of positive culture for candidiasis ranged from two to 67 days(mean, 15 days). Radiographic(n=42) and thin-section CT findings(n=13) were retrospectively analyzed. The onset, pattern, size, distribution and persistence of parenchymal abnormalities as well as the presence or absence of pleural effusions, mediastinal lymphadenopathy and cardiomegaly were assessed. On chest radiographs, positive findings were noticed in 61.9%(26/42) and on thin-section CT, in 76.9%(10/13). The most frequent radiographic finding was pulmonary nodule(s), observed in 14 patients(33.3%); in 13, these were bilateral. Bronchovascular bundle thickening(n=6, 14.3%), consolidation(n=4, 9.5%), cardiomegaly(n=6, 14.3%) and pleural effusion(n=4, 9.5%) were also observed. Those lesions appeared eight to 129 days(mean, 33 days) after the burn. Radiographic abnormalities persisted for seven to 115(mean, 35) days, regardless of the treatment. Thin-section CT showed parenchymal abnormalities in 10/13 patients(76.9%) and subpleural nodules of less than 1cm in diameter and without halo in all patients. Cardiomegaly, pleural effusion and mediastinal adenopathy were observed on CT in 5(38.5%), 4(30.8%) and 2(15.4%) of the 13 patients, respectively. In a high proportion of patients with burn-associated candidemia, chest radiograph and thin-section CT findings were positive. The most frequent radiographic parenchymal abnormality was multiple bilateral nodules

  16. Dysplastic gangliocytoma of the cerebellum (Lhermitte-Duclos disease). Case report with CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Uki, Jiro; Kanda, Shinji; Asakura, Ken; Takeda, Fumikazu

    1985-08-01

    A case of dysplastic gangliocytoma of the cerebellum, or Lhermitte-Duclos disease, is reported along with its CT findings, and the cases so far reported in the literature are reviewed. This is the 50th case report since the first description in 1920. This 61-year-old female had suffered from right hemifacial spasms for more than 20 years and from bilateral tinnitus with auditory disturbances for two years. Four years before admission, she underwent gastric resection and cancer chemotherapy for gastric cancer. Plain craniograms showed a thinned and ballooned occipital squama on the right side. Vertebral angiograms revealed a large tumor stain, with early venous filling, in the right posterior fossa. A CT scan showed a large, low-density mass, with small calcified areas in it, in the right posterior fossa. A postcontrast CT scan revealed no contrast enhancement, except for dilated vascular enhancement, within the tumor. No hydrocephalus was observed. Metrizamide CT cisternography revealed a huge intraaxial mass compressing the brain stem. (J.P.N.).

  17. STEM mode in the SEM for the analysis of cellular sections prepared by ultramicrotome sectioning

    International Nuclear Information System (INIS)

    Hondow, N; Harrington, J; Brydson, R; Brown, A

    2012-01-01

    The use of the dual imaging capabilities of a scanning electron microscope fitted with a transmitted electron detector is highlighted in the analysis of samples with importance in the field of nanotoxicology. Cellular uptake of nanomaterials is often examined by transmission electron microscopy of thin sections prepared by ultramicrotome sectioning. Examination by SEM allows for the detection of artefacts caused by sample preparation (eg. nanomaterial pull-out) and the complementary STEM mode permits study of the interaction between nanomaterials and cells. Thin sections of two nanomaterials of importance in nanotoxicology (cadmium selenide quantum dots and single walled carbon nanotubes) are examined using STEM mode in the SEM.

  18. Characterization of the relation between CT technical parameters and accuracy of quantification of lung attenuation on quantitative chest CT.

    Science.gov (United States)

    Trotta, Brian M; Stolin, Alexander V; Williams, Mark B; Gay, Spencer B; Brody, Alan S; Altes, Talissa A

    2007-06-01

    The purpose of this study was to assess the compromise between CT technical parameters and the accuracy of CT quantification of lung attenuation. Materials that simulate water (0 H), healthy lung (-650 H), borderline emphysematous lung (-820 H), and severely emphysematous lung (-1,000 H) were placed at both the base and the apex of the lung of an anthropomorphic phantom and outside the phantom. Transaxial CT images through the samples were obtained while the effective tube current was varied from 440 to 10 mAs, kilovoltage from 140 to 80 kVp, and slice thickness from 0.625 to 10 mm. Mean +/- SD attenuation within the samples and the standard quantitative chest CT measurements, the percentage of pixels with attenuation less than -910 H and 15th percentile of attenuation, were computed. Outside the phantom, variations in CT parameters produced less than 2.0% error in all measurements. Within the anthropomorphic phantom at 30 mAs, error in measurements was much larger, ranging from zero to 200%. Below approximately 80 mAs, mean attenuation became increasingly biased. The effects were most pronounced at the apex of the lungs. Mean attenuation of the borderline emphysematous sample of apex decreased 55 H as the tube current was decreased from 300 to 30 mAs. Both the 15th percentile of attenuation and percentage of pixels with less than -910 H attenuation were more sensitive to variations in effective tube current than was mean attenuation. For example, the -820 H sample should have 0% of pixels less than -910 H, which was true at 400 mA. At 30 mA in the lung apex, however, the measurement was highly inaccurate, 51% of pixels being below this value. Decreased kilovoltage and slice thickness had analogous, but lesser, effects. The accuracy of quantitative chest CT is determined by the CT acquisition parameters. There can be significant decreases in accuracy at less than 80 mAs for thin slices in an anthropomorphic phantom, the most pronounced effects occurring in the lung

  19. Normal CT measurement of sellar and juxtasellar structures

    International Nuclear Information System (INIS)

    Kim, Bo Hyun; Chung, Jin Wook; Han, Moon Hee; Chang, Kee Hyun

    1988-01-01

    The thorough knowledge of precise anatomy of the sellar, parasellar and suprasellar regions and of normal computed tomographic (CT) features in those areas are very important because there are many tiny but essential structures in which pathology makes only minute changes and so meticulous investigations are required. We performed direct coronal thin section CT scan of sellar and juxtasellar regions in 58 cases in order to evaluate normal CT features such as CT densities, shapes and sizes of normal sellar and juxtasellar structures. The results obtained are as follows: 1.The CT densities of pituitary glands were 87 ± 23 in anterior lobe and 69 ± 22 in posterior lobe. The latter was significantly less dense than the former. Posterior lobes could be identified as oval low density area in sagittal reconstruction in 18/58 (31%). Mean pituitary height was 6.5 ± 1.5mm. In young females of childbearing age, mean height was 7.0 ± 1.7mm. Upper margins of pituitary glands were flat in 29 cases (50%), upward convex in 16 cases (28%), and upward concave in 13 cases (22%). Upper margins of pituitary glands were upward convex in 8/15 (53%) of young female of childbearing age. Pituitary densities were homogeneous in 36 cases (77%) and heterogeneous in 7 cases (15%), and 4 cases (7%) show focal pituitary low density that is greater than 3mm in diameter. 2.Moderate to severe degree of cisternal herniation was found in 10 cases (17%): only 1 case before the age of 30, and 9 cases after the age of 30. 3.The lateral margins of cavernous sinus were bilaterally flat in 42 cases (72%), bilaterally convex in 3 cases (5%), unilaterally convex in 12 cases (21%), and unilaterally concave only in 1 case (2%). The third cranial nerves were found as symmetric filling defects in superolateral aspect of anterior cavernous sinus in most of the cases, the maximal size of which was 2.7 ± 0.9mm in diameter and did not exceed 3.5mm. The other cranial nerves were less frequently identified as

  20. Development of a 3-dimensional CT using an image intensifier

    International Nuclear Information System (INIS)

    Toyofuku, Fukai

    1992-01-01

    A prototype of three-dimensional CT (Fluoroscopic CT) has been developed using an image intensifier as a two-dimensional X-ray detector. A patient on a rotating table is projected onto an image intensifier by a cone beam of X-ray from the X-ray tube. A total of 390 projection images covering 180 degrees are acquired in a single scan (13 sec) and stored on a digital frame recorder (512 x 256 x 8-bit x 480). The transverse axial images are reconstructed by using the usual CT reconstruction algorithm, while longitudinal section images such as sagittal, coronal, oblique, and panoramic images are obtained by directly back-projecting the filtered projection image onto the sections. The radiation exposure was measured with an ionization chamber, and the exposure of the present fluoroscopic CT is about 10 to 20 times less than that of conventional X-ray CT. A similar monochromatic X-ray CT system has also been developed using synchrotron radiation. Large area parallel X-rays are obtained from a wiggler beam using a silicon crystal with [311] asymmetric reflection. By taking two images above and below iodine K-absorption edge (33.17 keV), iodine image is obtained. (author)

  1. Branchial cleft anomalies: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Seok, Eul Hye; Park, Chan Sup [College of Medicine, Inha University, Seongnam (Korea, Republic of)

    1994-04-15

    The purpose of this paper is to describe the CT findings of a variety of branchial cleft anomalies in the head and neck area. We reviewed the CT findings of 16 patients with neck lesion pathologically proved as branchial cleft anomalies. There were two first and 12 second branchial cleft cysts, one first and one second branchial cleft sinuses. Two cases of first branchial cleft cysts were manifested as thin-walled, cystic masses at auricular area. One first branchial cleft sinus was an external opening type and manifested as an ill-defined, enhancing solid lesion at posterior auricular area. All 12 cases of second branchial cleft cysts demonstrated a typical location, displacing the sternocleidomastoid muscle posteriorly, the carotid artery and internal jugular vein complex medially and the submandibular gland anteriorly. Eight cases of second branchial cleft cysts were seen as fluid-filled, round or ovoid-shaped cysts, and 3 cases of them were seen as irregular-shaped cysts. In one case, suppurative adenopathy with loss of soft tissue planes around the cyst was observed. One case of second branchial cleft sinus was manifested as a tubular-shaped, enhancing lesion at submental area and containing external opening site draining into the anterior border of the sternocleidomastoid muscle. We conclude that CT provides important diagnostic and therapeutic information in patients with a neck mass believed to be a branchial cleft anomaly, as it can differentiate various forms of the branchial anomalies by their characteristic location and shape.

  2. Branchial cleft anomalies: CT evaluation

    International Nuclear Information System (INIS)

    Seok, Eul Hye; Park, Chan Sup

    1994-01-01

    The purpose of this paper is to describe the CT findings of a variety of branchial cleft anomalies in the head and neck area. We reviewed the CT findings of 16 patients with neck lesion pathologically proved as branchial cleft anomalies. There were two first and 12 second branchial cleft cysts, one first and one second branchial cleft sinuses. Two cases of first branchial cleft cysts were manifested as thin-walled, cystic masses at auricular area. One first branchial cleft sinus was an external opening type and manifested as an ill-defined, enhancing solid lesion at posterior auricular area. All 12 cases of second branchial cleft cysts demonstrated a typical location, displacing the sternocleidomastoid muscle posteriorly, the carotid artery and internal jugular vein complex medially and the submandibular gland anteriorly. Eight cases of second branchial cleft cysts were seen as fluid-filled, round or ovoid-shaped cysts, and 3 cases of them were seen as irregular-shaped cysts. In one case, suppurative adenopathy with loss of soft tissue planes around the cyst was observed. One case of second branchial cleft sinus was manifested as a tubular-shaped, enhancing lesion at submental area and containing external opening site draining into the anterior border of the sternocleidomastoid muscle. We conclude that CT provides important diagnostic and therapeutic information in patients with a neck mass believed to be a branchial cleft anomaly, as it can differentiate various forms of the branchial anomalies by their characteristic location and shape

  3. Free-breathing cine CT for the diagnosis of tracheomalacia in young children

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2013-01-01

    Tracheomalacia is characterized by excessive expiratory collapse of the trachea. To investigate the accuracy of free-breathing cine CT for diagnosis of tracheomalacia in young children with bronchoscopy as reference standard. In a retrospective study (May 2001-July 2008), a patient group (n = 27) of children with bronchoscopic evidence of tracheomalacia, and a control group (n = 320) underwent free-breathing cine CT. The tracheal shape on free-breathing cine CT was classified as round, lunate, elongated or crescentic. Cross-sectional area change of the trachea and age were compared between the groups and the diagnostic performance of free-breathing cine CT for tracheomalacia was evaluated. The patient group showed significantly greater cross-sectional area change of the trachea (57.2% ± 22.2% vs. 10.6% ± 11.2%, P < 0.001) than the control group. If a cross-sectional area change of the trachea of 31.6% was used as a cut-off value for the diagnosis of tracheomalacia, the sensitivity, specificity and accuracy of cine CT were 96.3% (26/27), 97.2% (311/320) and 97.1% (337/347), respectively. If a crescentic shape during the expiratory phase was used, the sensitivity, specificity and accuracy were 51.9% (14/27), 98.8% (316/320) and 95.1% (330/347), respectively. Free-breathing cine CT has potential to provide the diagnosis of tracheomalacia in young children. (orig.)

  4. Development of planar CT system for multi-layer PCB inspection

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Youn, Hanbean; Kam, Soohwa; Park, Eunpyeong; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2015-05-15

    X-ray defect inspection apparatus can be used in the production line to inspect the PCB. However, a simple X-ray radiography cannot discriminate defects from the multi-layer PCBs because the layers of them overlays the defects. To complement this issue, computed tomography (CT) technology is applied to the NDT system which can offer 3-dimensional information of object. However, CT requires hundreds of projection images to examine a single PCB, hence real-time inspection is nearly impossible. In this study, we develop a planar computed tomography (pCT) system appropriate for the multi-layer PCB inspection. For the image reconstruction of planar cross-section images, we use the digital tomosynthesis (DTS) concept in association with the limited angle scanning. and performance characterization of the pCT system for the PCB inspection. The 3-d Fourier characteristics and more quantitative performance, such as contrast, uniformity, depth resolution will be presented. The cross-sectional images of multi-layer PCBs will also be demonstrated.

  5. X-ray and CT diagnosis of intraosseous ganglion

    International Nuclear Information System (INIS)

    Gong Xiangyang; Zhang Weimin; Yan Shigui

    2002-01-01

    Objective: To investigate the pathogenesis, clinical manifestations, imaging features, and differential diagnosis of intraosseous ganglion. Methods: Clinical and imaging features of 15 cases (5 men, 10 women; mean age 39.7 years) with intraosseous ganglia were retrospectively analyzed. There were 17 lesions, including 6 acetabular, 4 lunate, 3 proximal ends of tibia, 1 major tuberculum of humeral, 1 femoral head, 1 scaphoid, and 1 phalange. Results: ( 1 ) Common radiological features included a unilocular or multilocular cyst surrounded by a full and thin rim of sclerotic: bone in the subchondral epiphysis without any signs of degenerative joint disease. (2) Lesions were displayed as well-defined round radiolucent defect or multi-cystic changes with surrounding bony sclerosis or cystic and expansile change with irregular shape on CT scans. (3) CT showed an intraosseous ganglion communicating with adjacent joint in 1 patient. (4) CT values of the lesions were between 15 - 80 HU. (5) Gas in the cyst could be seen in 3 cases. Conclusion: Combined with patient's age, lesion distribution, clinical manifestations, and imaging features, it is possible to make a correct diagnosis of intraosseous ganglion

  6. Characterization of the adhesion of thin film by Cross-Sectional Nanoindentation. Analysis of the substrate edge chipping and the film delamination

    Science.gov (United States)

    Felder, Eric; Roy, Sébastien; Darque-Ceretti, Evelyne

    2011-07-01

    Cross-Sectional Nanoindentation (CSN) is a recent method for adhesion measurement of nanoscale thin films in Ultra-Large Scale Integrated circuits. In the case of ductile thin films, the motion of the substrate chip implies significant plastic deformation of the film and complex geometry of delaminated areas. This article recalls first the experimental procedure and the two main features observed in this test performed on various plane copper films deposited on silicon: the critical force producing silicon edge chipping increases linearly with the distance of the indenter to the interface; on the section the delaminated length of the film ( a-b) is proportional to the residual silicon chip displacement u and the ratio S=u/(a-b) depends on the manufacturing process of the film, and is so related to its adhesion to the substrate. One proposes a simple analysis of the silicon edge chipping. Then a model of pull-off of an elastic-strain hardening plastic film is developed, which suggests an explanation for the delamination process. Application of the model to experimental results starting from films plastic properties deduced from nanoindentation measurements provides plausible results. Some improvements for performing the CSN test are proposed in order to make easier its interpretation.

  7. Indirect Fabrication of Lattice Metals with Thin Sections Using Centrifugal Casting.

    Science.gov (United States)

    Mun, Jiwon; Ju, Jaehyung; Thurman, James

    2016-05-14

    One of the typical methods to manufacture 3D lattice metals is the direct-metal additive manufacturing (AM) process such as Selective Laser Melting (SLM) and Electron Beam Melting (EBM). In spite of its potential processing capability, the direct AM method has several disadvantages such as high cost, poor surface finish of final products, limitation in material selection, high thermal stress, and anisotropic properties of parts. We propose a cost-effective method to manufacture 3D lattice metals. The objective of this study is to provide a detailed protocol on fabrication of 3D lattice metals having a complex shape and a thin wall thickness; e.g., octet truss made of Al and Cu alloys having a unit cell length of 5 mm and a cell wall thickness of 0.5 mm. An overall experimental procedure is divided into eight sections: (a) 3D printing of sacrificial patterns (b) melt-out of support materials (c) removal of residue of support materials (d) pattern assembly (e) investment (f) burn-out of sacrificial patterns (g) centrifugal casting (h) post-processing for final products. The suggested indirect AM technique provides the potential to manufacture ultra-lightweight lattice metals; e.g., lattice structures with Al alloys. It appears that the process parameters should be properly controlled depending on materials and lattice geometry, observing the final products of octet truss metals by the indirect AM technique.

  8. Nontraumatic spontaneous rupture of the kidney : etiology and CT findings

    International Nuclear Information System (INIS)

    Heo, Tae Haeng; Jeon, Hae Jeong; Shin, Hyun Joon; Kim, Bo Hyun; Cho, Kyoung Sik; Kim, Young Hwa; Kim, Seung Hyup; Park, Churl Min

    1997-01-01

    To evaluate the usefulness of CT scanning in determining the etiology of spontaneous rupture of the kidney We retrospectively analyzed the CT findings of spontaneous rupture of the kidney in eleven patients, Four were male and seven were female, and they were aged between 20 and 71 (mean, 46.6) years. Both pre- and post-contrast enhanced CT scanning was performed in all patients. Spontaneous renal rupture was induced in seven cases by neoplasms (three angiomyolipomas, three renal cell carcinomas, and one metastatic choriocarcinoma), in three cases by infection or inflammation (acute and chronic pyelonephritis, and renal abscess), and in one, by renal cyst. Common CT findings of rupture of the kidney were the accumulation of high density fluid in the perirenal and anterior pararenal space, and inhomogeneous irregular low density of renal parenchyma and the rupture site. Angiomyolipoma showed fat and an angiomatous component in the lesion, while acute and chronic pyelonephrities revealed thinning of the renal parenchyma and an irregular renal outline. Renal cell carcinoma showed a dense soft tissue mass in the parenchyma. Well-defined, round low-density lesions were noted in the case of renal cyst and renal abscess. CT is very useful in diagnosing and determining the etiology of non-traumatic spontaneous rupture of the kidney and plays an important role in the evaluation of emergency cases

  9. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  10. ECG gated NMR-CT for cardiovascular diseases

    International Nuclear Information System (INIS)

    Nishikawa, J.; Machida, K.; Iio, M.; Yoshimoto, N.; Sugimoto, T.; Kawaguchi, H.; Mano, H.

    1984-01-01

    The authors applied NMR-CT to cardiac study with ECG gated technique to evaluate the left ventricular (LV) function and compared it with cardiovascular nuclear medicine study (NM). The NMR-CT machine has resistive air-core magnet with 0.15 Tesla. The saturation recovery image or inversion recovery image were obtained as 256 x 256 matrix and 15 mm in thickness. The study population was ten patients who were evaluated both by NMR image and by NM performed within one week interval. The heart muscle was able to be visualized without any contrast material nor radioisotopes in inversion recovery images, whereas saturation recovery images failed to separate heart muscle from blood pool. The wall motions of LV in both methods were well correlated except for inferior wall. The values of ejection fraction in NMR image were moderately low, but two modalities showed satisfactory correlation (r=0.85). The region of myocardial infarction was revealed as wall thinning and/or wall motion abnormality. It is still preliminary to draw a conclusion, however, it can be said that in the evaluation of LV function, method by NMR might be of equal value to those of NM. It can be certain that eventually gated NMR-CT will become more effective method for various aspects of cardiovascular evaluation

  11. 3D Interpolation Method for CT Images of the Lung

    Directory of Open Access Journals (Sweden)

    Noriaki Asada

    2003-06-01

    Full Text Available A 3-D image can be reconstructed from numerous CT images of the lung. The procedure reconstructs a solid from multiple cross section images, which are collected during pulsation of the heart. Thus the motion of the heart is a special factor that must be taken into consideration during reconstruction. The lung exhibits a repeating transformation synchronized to the beating of the heart as an elastic body. There are discontinuities among neighboring CT images due to the beating of the heart, if no special techniques are used in taking CT images. The 3-D heart image is reconstructed from numerous CT images in which both the heart and the lung are taken. Although the outline shape of the reconstructed 3-D heart is quite unnatural, the envelope of the 3-D unnatural heart is fit to the shape of the standard heart. The envelopes of the lung in the CT images are calculated after the section images of the best fitting standard heart are located at the same positions of the CT images. Thus the CT images are geometrically transformed to the optimal CT images fitting best to the standard heart. Since correct transformation of images is required, an Area oriented interpolation method proposed by us is used for interpolation of transformed images. An attempt to reconstruct a 3-D lung image by a series of such operations without discontinuity is shown. Additionally, the same geometrical transformation method to the original projection images is proposed as a more advanced method.

  12. CT evaluation of cavitary lung lesions: focused on lung cancer, tuberculosis and abscess

    International Nuclear Information System (INIS)

    Lee, Young Rahn; Kim, Myung Gyu; Kang, Eun Young; Suh, Won Hyuck

    1992-01-01

    Differential diagnosis of cavitary lung lesions is frequently problematic. We studied 35 patients with cavitary lung lesions, consisting of lung cancer (17 patients), pulmonary tuberculosis (11 patients), and lung abscess (7 patients). We analysed CT scans in terms of irregularities of the cavity wall, maximum wall thickness, the presence of air-fluid level, location of the cavity within the mass, number of cavities within the mass, size of the cavity and the presence of calcification within the mass. Cancer cavity showed irregular inner (100%) and outer margins (100%), and thick wall (mean, 1.94 cm), eccentrical location (94%) and multiplicity within a mass (38%). Tuberculous cavity showed smooth inner (56%) and irregular outer margins (75%), thin wall (mean 0.96 cm), central location (62%), and multiplicity in one patient (36%). Abscess cavity showed irregular inner (57%) and outer margins (91%), relatively thin wall (mean 1.0 cm), central location (57%), and air-fluid level (86%). CT scan could differentiate malignant lesions from benign condition such as tuberculosis and lung abscess by observing characteristics of the cavities

  13. CT evaluation of cavitary lung lesions: focused on lung cancer, tuberculosis and abscess

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Rahn; Kim, Myung Gyu; Kang, Eun Young; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of)

    1992-11-15

    Differential diagnosis of cavitary lung lesions is frequently problematic. We studied 35 patients with cavitary lung lesions, consisting of lung cancer (17 patients), pulmonary tuberculosis (11 patients), and lung abscess (7 patients). We analysed CT scans in terms of irregularities of the cavity wall, maximum wall thickness, the presence of air-fluid level, location of the cavity within the mass, number of cavities within the mass, size of the cavity and the presence of calcification within the mass. Cancer cavity showed irregular inner (100%) and outer margins (100%), and thick wall (mean, 1.94 cm), eccentrical location (94%) and multiplicity within a mass (38%). Tuberculous cavity showed smooth inner (56%) and irregular outer margins (75%), thin wall (mean 0.96 cm), central location (62%), and multiplicity in one patient (36%). Abscess cavity showed irregular inner (57%) and outer margins (91%), relatively thin wall (mean 1.0 cm), central location (57%), and air-fluid level (86%). CT scan could differentiate malignant lesions from benign condition such as tuberculosis and lung abscess by observing characteristics of the cavities.

  14. Bone demarcation of the temporomandibular joint. Validity of clinical assessment of bone thickness by means of CT

    International Nuclear Information System (INIS)

    Ahlqvist, J.B.; Isberg, A.M.

    1998-01-01

    Purpose: To study the CT depiction of bone demarcations in the temporomandibular joint, using conventional window level and window width; and to evaluate observer performance in estimating bone thickness in these images. Material and Methods: Seven joint specimens were imaged by CT and then cryosectioned. The measurements of bone wall thickness in the images were compared to the true bone thickness at each cutting level. In addition, 4 experienced radiologists estimated the thickness of the bone walls in the images. Results: The relative difference between the CT reproduction and the true bone thickness was small for bone walls thicker than 2 mm. This difference increased with the decrease in bone thickness and the increase in the inclination of the bone wall from the perpendicular to the image plane. Bone walls thinner than 1 mm were reproduced as considerably thicker than their true thickness. This resulted in a clinical overestimation of bone thickness. Conclusion: Both the CT representation and the interpretation of bone demarcation in the temporomandibular joint may constitute a problem. Partial volume averaging effects can result in an overestimation of bone dimensions amounting to 200% for thin bones. The central white zone in images of thin bone walls obtained with the parameters described here could serve as an indicator that could help to reduce the risk of overestimating bone thickness. (orig.)

  15. 3D visualisation of the middle ear and adjacent structures using reconstructed multi-slice CT datasets, correlating 3D images and virtual endoscopy to the 2D cross-sectional images

    International Nuclear Information System (INIS)

    Rodt, T.; Ratiu, P.; Kacher, D.F.; Anderson, M.; Jolesz, F.A.; Kikinis, R.; Becker, H.; Bartling, S.

    2002-01-01

    The 3D imaging of the middle ear facilitates better understanding of the patient's anatomy. Cross-sectional slices, however, often allow a more accurate evaluation of anatomical structures, as some detail may be lost through post-processing. In order to demonstrate the advantages of combining both approaches, we performed computed tomography (CT) imaging in two normal and 15 different pathological cases, and the 3D models were correlated to the cross-sectional CT slices. Reconstructed CT datasets were acquired by multi-slice CT. Post-processing was performed using the in-house software ''3D Slicer'', applying thresholding and manual segmentation. 3D models of the individual anatomical structures were generated and displayed in different colours. The display of relevant anatomical and pathological structures was evaluated in the greyscale 2D slices, 3D images, and the 2D slices showing the segmented 2D anatomy in different colours for each structure. Correlating 2D slices to the 3D models and virtual endoscopy helps to combine the advantages of each method. As generating 3D models can be extremely time-consuming, this approach can be a clinically applicable way of gaining a 3D understanding of the patient's anatomy by using models as a reference. Furthermore, it can help radiologists and otolaryngologists evaluating the 2D slices by adding the correct 3D information that would otherwise have to be mentally integrated. The method can be applied to radiological diagnosis, surgical planning, and especially, to teaching. (orig.)

  16. Differential diagnosis of primary nasopharyngeal lymphoma and nasopharyngeal carcinoma focusing on CT, MRI, and PET/CT.

    Science.gov (United States)

    Cho, Kyu-Sup; Kang, Dae-Woon; Kim, Hak-Jin; Lee, Jong-Kil; Roh, Hwan-Jung

    2012-04-01

    No study has done a comparative analysis of radiologic imaging findings between primary nasopharyngeal lymphoma (PNL) and nasopharyngeal carcinoma (NPC). The purpose of this study was to analyze computed tomography (CT) and magnetic resonance (MR) images and to evaluate the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/CT between PNL and NPC, knowing the imaging features that distinguish PNL from NPC. Cross-sectional study. University tertiary care facility. The authors analyzed the features on CT, MR imaging, and PET/CT of 16 patients diagnosed with PNL and 32 patients diagnosed with NPC histopathologically. Patients with PNL had a larger tumor volume and showed symmetry of tumor shape than did patients with NPC. Patients with PNL also had higher tumor homogeneity than NPC patients on CT, T2-weighted, and postcontrast MR images. All PNL patients showed a high degree of enhancement without invasion to the adjacent deep structure. The involvement of the Waldeyer ring was significantly higher in PNL patients. Cervical and retropharyngeal lymphadenopathy and PET/CT SUV max showed no significant difference between PNL and NPC. If the images present a bulky, symmetric nasopharyngeal mass with marked homogeneity, a high degree of enhancement, and a higher Waldeyer ring involvement combined with no invasion into the deep structure, PNL should be considered over NPC.

  17. CT images of an anthropomorphic and anthropometric male pelvis phantom

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  18. CT images of an anthropomorphic and anthropometric male pelvis phantom

    International Nuclear Information System (INIS)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de

    2009-01-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  19. The impact of cluster thinning on fertility and berry and wine composition of 'Blauer Portugieser' (Vitis vinifera L. grapevine variety

    Directory of Open Access Journals (Sweden)

    Jan Reščič

    2015-12-01

    Full Text Available Aim: Two different yield reductions based on cluster thinning (CT were performed to determine their impact on vine growth, yield, and grape and wine composition of 'Blauer Portugieser' grapevine variety. Methods and results: Two levels of cluster thinning (limited CT1 – 20-30 % and severe CT2 – 40-50 % cluster reduction were applied at the pea-size berry (BBCH 75 phenological stage in 2007, 2008 and 2011. The potential impact of CT was determined by measurements of vine growth and fertility potential, berry weight, berry colour, soluble solids content, titratable acidity, pH and total phenolics. Additionally, for the first time, individual phenolic compounds were identified and quantified in berry skin and wine by HPLC-MS. In general, CT of 'Blauer Portugieser' significantly decreased titratable acidity in grape and wine, and increased pH and chromatic parameters in grape and alcohol content and volatile acidity in wine. A significant decrease in yield per vine (of 0.92 kg of grape/vine, together with an increase in soluble solids (of 2.8 °Brix in grape and pH and total extract content in wine was only observed in severe CT (CT2. Furthermore, CT2 significantly increased the content of total anthocyanins, flavonols and hydroxycinnamic acids, but not total flavanols, in grape and wine. CT2 significantly increased the content and proportion of p-coumaroyl pentose in grape and wine, catechin in grape, epicatechin in wine, quercetin-3-glucuronide (the main flavonol in 'Blauer Portugieser' in grape and wine, the content of myricetin-3-glucoside in grape, and the content of 3-glucosides of laricitrin, myricetin and quercetin in wine. Finally, CT2 increased the content and the proportion of 3-glucosides of delphinidin, petunidin and peonidin but decreased the proportion of malvidin-3-glucoside in grape and wine. Conclusion: A significant impact on yield and grape and wine composition was observed, particularly in the CT2 treatment, in which the

  20. Clinical applications of 2D and 3D CT imaging of the airways - a review

    International Nuclear Information System (INIS)

    Salvolini, Luca; Bichi Secchi, Elisabetta; Costarelli, Leonardo; De Nicola, Maurizio

    2000-01-01

    Hardware and software evolution has broadened the possibilities of 2D and 3D reformatting of spiral CT and MR data set. In the study of the thorax, intrinsic benefits of volumetric CT scanning and better quality of reconstructed images offer us the possibility to apply additional rendering techniques to everyday clinical practice. Considering the large number and redundancy of possible post-processing imaging techniques that we can apply to raw CT sections data, it is necessary to precisely set a well-defined number of clinical applications of each of them, by careful evaluation of their benefits and possible pitfalls in each clinical setting. In diagnostic evaluation of pathological processes affecting the airways, a huge number of thin sections is necessary for detailed appraisal and has to be evaluated, and information must then be transferred to referring clinicians. By additional rendering it is possible to make image evaluation and data transfer easier, faster, and more effective. In the study of central airways, additional rendering can be of interest for precise evaluation of the length, morphology, and degree of stenoses. It may help in depicting exactly the locoregional extent of central tumours by better display of relations with bronchovascular interfaces and can increase CT/bronchoscopy sinergy. It may allow closer radiotherapy planning and better depiction of air collections, and, finally, it could ease panoramic evaluation of the results of dynamic or functional studies, that are made possible by increased speed of spiral scanning. When applied to the evaluation of peripheral airways, as a completion to conventional HRCT scans, High-Resolution Volumetric CT, by projection slabs applied to target areas of interest, can better depict the profusion and extension of affected bronchial segments in bronchiectasis, influence the choice of different approaches for tissue sampling by better evaluation of the relations of lung nodules with the airways, or help

  1. Clinical applications of 2D and 3D CT imaging of the airways - a review

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca E-mail: u.salvolini@popcsi.unian.it; Bichi Secchi, Elisabetta; Costarelli, Leonardo; De Nicola, Maurizio

    2000-04-01

    Hardware and software evolution has broadened the possibilities of 2D and 3D reformatting of spiral CT and MR data set. In the study of the thorax, intrinsic benefits of volumetric CT scanning and better quality of reconstructed images offer us the possibility to apply additional rendering techniques to everyday clinical practice. Considering the large number and redundancy of possible post-processing imaging techniques that we can apply to raw CT sections data, it is necessary to precisely set a well-defined number of clinical applications of each of them, by careful evaluation of their benefits and possible pitfalls in each clinical setting. In diagnostic evaluation of pathological processes affecting the airways, a huge number of thin sections is necessary for detailed appraisal and has to be evaluated, and information must then be transferred to referring clinicians. By additional rendering it is possible to make image evaluation and data transfer easier, faster, and more effective. In the study of central airways, additional rendering can be of interest for precise evaluation of the length, morphology, and degree of stenoses. It may help in depicting exactly the locoregional extent of central tumours by better display of relations with bronchovascular interfaces and can increase CT/bronchoscopy sinergy. It may allow closer radiotherapy planning and better depiction of air collections, and, finally, it could ease panoramic evaluation of the results of dynamic or functional studies, that are made possible by increased speed of spiral scanning. When applied to the evaluation of peripheral airways, as a completion to conventional HRCT scans, High-Resolution Volumetric CT, by projection slabs applied to target areas of interest, can better depict the profusion and extension of affected bronchial segments in bronchiectasis, influence the choice of different approaches for tissue sampling by better evaluation of the relations of lung nodules with the airways, or help

  2. Application of synchrotron through-the-substrate microdiffraction to crystals in polished thin sections

    Directory of Open Access Journals (Sweden)

    Jordi Rius

    2015-07-01

    Full Text Available The synchrotron through-the-substrate X-ray microdiffraction technique (tts-μXRD is extended to the structural study of microvolumes of crystals embedded in polished thin sections of compact materials [Rius, Labrador, Crespi, Frontera, Vallcorba & Melgarejo (2011. J.Synchrotron Rad. 18, 891–898]. The resulting tts-μXRD procedure includes some basic steps: (i collection of a limited number of consecutive two-dimensional patterns (frames for each randomly oriented crystal microvolume; (ii refinement of the metric from the one-dimensional diffraction pattern which results from circularly averaging the sum of collected frames; (iii determination of the reciprocal lattice orientation of each randomly oriented crystal microvolume which allows assigning the hkl indices to the spots and, consequently, merging the intensities of the different frames into a single-crystal data set (frame merging; and (iv merging of the individual crystal data sets (multicrystal merging to produce an extended data set suitable for structure refinement/solution. Its viability for crystal structure solution by Patterson function direct methods (δ recycling and for accurate single-crystal least-squares refinements is demonstrated with some representative examples from petrology in which different glass substrate thicknesses have been employed. The section of the crystal microvolume must be at least of the same order of magnitude as the focus of the beam (15 × 15 µm in the provided examples. Thanks to its versatility and experimental simplicity, this methodology should be useful for disciplines as disparate as petrology, materials science and cultural heritage.

  3. CT findings in gastrocolic fistula following percutaneous endoscopic gastrostomy

    International Nuclear Information System (INIS)

    Brown, Suki; McHugh, Kieran; Ledermann, Sarah; Pierro, Agostino

    2007-01-01

    We describe the CT findings in an initially asymptomatic boy aged 2 years 9 months with a gastrocolic fistula following percutaneous endoscopic gastrostomy (PEG) placement. The findings consisted of an unusual configuration of the gastrostomy tubing on an abdominal radiograph and upper gastrointestinal study indicating the possibility of transcolic PEG placement, which was confirmed with limited section CT. This well-known and major complication following a common procedure may be recognized on plain abdominal radiography, but it has not to our knowledge been documented previously on CT in a child. (orig.)

  4. CT findings in gastrocolic fistula following percutaneous endoscopic gastrostomy

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Suki [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); St. George' s Hospital, Radiology Department, London (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Ledermann, Sarah [Great Ormond Street Hospital for Children, Department of Nephrology, London (United Kingdom); Pierro, Agostino [Great Ormond Street Hospital for Children, Department of Surgery, London (United Kingdom)

    2007-02-15

    We describe the CT findings in an initially asymptomatic boy aged 2 years 9 months with a gastrocolic fistula following percutaneous endoscopic gastrostomy (PEG) placement. The findings consisted of an unusual configuration of the gastrostomy tubing on an abdominal radiograph and upper gastrointestinal study indicating the possibility of transcolic PEG placement, which was confirmed with limited section CT. This well-known and major complication following a common procedure may be recognized on plain abdominal radiography, but it has not to our knowledge been documented previously on CT in a child. (orig.)

  5. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  6. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  7. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Joo; Kang, Doo Kyung; Kim, Tae Hee [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2006-05-15

    The introduction of Multidetector-row CT (MDCT) has revolutionized the diagnostic strategy of multitrauma patients. The rapid acquisition of a large scanning volume with a thin slice collimation allows for motion-free images of high spatial resolution, and this enables the application of the multiplanar reformat (MPR) and 3D volume-rendering (VR) images. The MPR images more accurately demonstrate aortic rupture or dissection, diaphragmatic injuries and fracture of vertebrae, sternum and costal cartilages. Diagnosing vascular injuries can be aided by using the MIP images. Rib fracture, trachea and bronchial laceration are more easily detected by the 3D images, while airway and vascular injuries can be detected from performing virtual endoscopy. We introduce our current CT imaging protocol and we present our clinical experience with using MDCT in the assessment of patients with blunt thoracic trauma.

  8. 3D temporal subtraction on multislice CT images using nonlinear warping technique

    Science.gov (United States)

    Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio

    2007-03-01

    The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.

  9. Choroidal thinning in high myopia measured by optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Ikuno Y

    2013-05-01

    Full Text Available Yasushi Ikuno, Satoko Fujimoto, Yukari Jo, Tomoko Asai, Kohji NishidaDepartment of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, JapanPurpose: To investigate the rate of choroidal thinning in highly myopic eyes.Patients and methods: A retrospective observational study of 37 eyes of 26 subjects (nine males and 17 females, mean age 39.6 ± 7.7 years with high myopia but no pathologies who had undergone spectral domain optical coherence tomography and repeated the test 1 year later (1 ± 0.25 year at Osaka University Hospital, Osaka, Japan. Patients older than 50 years with visual acuity worse than 20/40 or with whitish chorioretinal atrophy involving the macula were excluded. Two masked raters measured the choroidal thicknesses (CTs at the foveda, 3 mm superiorly, inferiorly, temporally, and nasally on the images and averaged the values. The second examination was about 365 days after the baseline examination. The CT reduction per year (CTRPY was defined as (CT 1 year after - baseline CT/days between the two examinations × 365. The retinal thicknesses were also investigated.Results: The CTRPY at the fovea was −1.0 ± 22.0 µm (range –50.2 to 98.5 at the fovea, –6.5 ± 24.3 µm (range −65.8 to 90.2 temporally, –0.5 ± 22.3 µm (range –27.1 to 82.5 nasally, –9.7 ± 21.7 µm (range –40.1 to 60.1 superiorly, and –1.4 ± 25.5 µm (range –85.6 to 75.2 inferiorly. There were no significant differences in the CTRPY at each location (P = 0.34. The CT decreased significantly (P < 0.05 only superiorly. The superior CTRPY was negatively correlated with the axial length (P < 0.05. The retinal thickness at the fovea did not change. Stepwise analysis for CTRPY selected axial length (P = 0.04, R2 = 0.13 and age (P = 0.08, R2 = 0.21 as relevant factors.Conclusions: The highly myopic choroid might gradually thin and be affected by many factors. Location and axial length are key factors to regulate the rate of choroidal

  10. Data explosion: the challenge of multidetector-row CT

    International Nuclear Information System (INIS)

    Rubin, Geoffrey D.

    2000-01-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed

  11. 3D intrathoracic region definition and its application to PET-CT analysis

    Science.gov (United States)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2014-03-01

    Recently developed integrated PET-CT scanners give co-registered multimodal data sets that offer complementary three-dimensional (3D) digital images of the chest. PET (positron emission tomography) imaging gives highly specific functional information of suspect cancer sites, while CT (X-ray computed tomography) gives associated anatomical detail. Because the 3D CT and PET scans generally span the body from the eyes to the knees, accurate definition of the intrathoracic region is vital for focusing attention to the central-chest region. In this way, diagnostically important regions of interest (ROIs), such as central-chest lymph nodes and cancer nodules, can be more efficiently isolated. We propose a method for automatic segmentation of the intrathoracic region from a given co-registered 3D PET-CT study. Using the 3D CT scan as input, the method begins by finding an initial intrathoracic region boundary for a given 2D CT section. Next, active contour analysis, driven by a cost function depending on local image gradient, gradient-direction, and contour shape features, iteratively estimates the contours spanning the intrathoracic region on neighboring 2D CT sections. This process continues until the complete region is defined. We next present an interactive system that employs the segmentation method for focused 3D PET-CT chest image analysis. A validation study over a series of PET-CT studies reveals that the segmentation method gives a Dice index accuracy of less than 98%. In addition, further results demonstrate the utility of the method for focused 3D PET-CT chest image analysis, ROI definition, and visualization.

  12. Cross-Sectional Analysis of Neurocognitive Function, Retinopathy, and Retinal Thinning by Spectral-Domain Optical Coherence Tomography in Sickle Cell Patients.

    Science.gov (United States)

    Oltra, Erica Z; Chow, Clement C; Wubben, Thomas; Lim, Jennifer I; Chau, Felix Y; Moss, Heather E

    2016-01-01

    The purpose was to examine the relationship between neurocognitive function and two distinct forms of retinopathy in sickle cell disease. Patients with sickle cell disease (n = 44, age range: 19-56 years, 70% female) were prospectively recruited for this cross-sectional study. Retinopathy was characterized by: (1) Presence of focal retinal thinning on spectral domain optical coherence tomography and (2) determination of the sickle retinopathy stage on funduscopic exam based on Goldberg classification. Neurocognitive function was assessed using the Philadelphia Brief Assessment of Cognition (PBAC), a validated test of cognition. Univariate and multivariate analyses for PBAC score outcomes were performed. Retinal thinning and retinopathy stage were primary variables of interest and age, gender, genotype, education, and history of stroke were covariates. Univariate analysis revealed associations with total PBAC score and age (P = 0.049), history of stroke (P = 0.04), and genotype (P retinopathy stage were not associated with each other in this sample. Neither the presence of focal retinal thinning nor degree of retinopathy was associated with total PBAC score in univariate or multivariate analyses. We find an association between lower cognitive function and older age, history of stroke and sickle cell genotype SS in patients with sickle cell disease. Our data do not provide evidence to support an association between cognitive function and retinopathy in sickle cell patients.

  13. Radiolucencies and cavitation in bronchioloalveolar carcinoma: CT-pathologic correlation

    International Nuclear Information System (INIS)

    Gaeta, M.; Bartiromo, G.; Caruso, R.; Blandino, A.; Scribano, E.; Pandolfo, I.

    1999-01-01

    Bronchioloalveolar carcinoma (BAC) is a polymorphic lung cancer the incidence of which is rising. The presence of intratumoral radiolucencies is an important feature of bronchioloalveolar carcinoma.The aim of this study was to present pictorially the spectrum of intratumoral radiolucencies visible in BAC. In 57 BACs studied with thin-slice CT, we identified six types of radiolucencies: (a) patent intratumoral bronchioles (air bronchiologram); (b) pseudocavitations; (c) cavitation; (d) serpentine radiolucencies; (e) internal alveologram; and (f) multiple cystic lesions. (orig.) (orig.)

  14. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Horger, M.; Thaiss, W.M.; Fritz, J.; Ditt, H.; Weisel, K.; Haap, M.; Kloth, Christopher

    2018-01-01

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ( WB MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p < 0.001). Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p < 0.001*) and significant decrease of minimal bone (p < 0.002*) in the SD/PR/VGPR/CR group. Qualitative MRI showed PD in 14/47 (29.7%) and SD/PR/VGPR/CR in 33/47 (70.3%). Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p < 0.001*). Imaging response monitoring using MRI is superior to CT only if qualitative parameters are used, whereas there was no

  15. Comparison of qualitative and quantitative CT and MRI parameters for monitoring of longitudinal spine involvement in patients with multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Horger, M.; Thaiss, W.M. [Eberhard-Karls-University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Fritz, J. [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Ditt, H. [Siemens AG Healthcare, Sector Imaging and Interventional Radiology, Forchheim (Germany); Weisel, K. [Eberhard-Karls-University Tuebingen, Department of Internal Medicine II, Tuebingen (Germany); Haap, M. [Eberhard-Karls-University Tuebingen, Department of Internal Medicine IV, Tuebingen, (Germany); Kloth, Christopher [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2018-03-15

    To compare qualitative and quantitative computed tomography (CT) and magnetic resonance imaging (MRI) parameters for longitudinal disease monitoring of multiple myeloma (MM) of the axial skeleton. We included 31 consecutive patients (17 m; mean age 59.20 ± 8.08 years) with MM, who underwent all baseline (n = 31) and at least one or more (n = 47) follow-up examinations consisting of multi-parametric non-enhanced whole-body MRI ({sub WB}MRI) and non-enhanced whole-body reduced-dose thin-section MDCT (NEWBMDCT) between 06/2013 and 09/2016. We classified response according to qualitative CT criteria into progression (PD), stable(SD), partial/very good partial (PR/VGPR) and complete response(CR), grouping the latter three together for statistical analysis because CT cannot reliably assess PR and CR. Qualitative MR-response criteria were defined and grouped similarly to CT using longitudinal quantification of signal-intensity changes on T1w/STIR/ T2*w and calculating ADC-values. Standard of reference was the hematological laboratory (M-gradient). Hematological response categories were CR (14/47, 29.7%), PR (2/47, 4.2%), SD (16/47, 34.0%) and PD (15/47, 29.9%). Qualitative-CT-evaluation showed PD in 12/47 (25.5%) and SD/PR/VGPR/CR in 35/47 (74.5%) cases. These results were confirmed by quantitative-CT in all focal lytic lesions (p < 0.001). Quantitative-CT at sites with diffuse bone involvement showed significant increase of maximum bone attenuation (p < 0.001*) and significant decrease of minimal bone (p < 0.002*) in the SD/PR/VGPR/CR group. Qualitative MRI showed PD in 14/47 (29.7%) and SD/PR/VGPR/CR in 33/47 (70.3%). Quantitative MRI diagnosis showed a statistically significant decrease in signal intensity on short tau inversion recovery sequences (STIR) in bone marrow in patients with diffuse bone marrow involvement achieving SD/PR/VGPR/CR (p < 0.001*). Imaging response monitoring using MRI is superior to CT only if qualitative parameters are used, whereas there was

  16. Occipital condyle fracture and ligament injury: imaging by CT

    International Nuclear Information System (INIS)

    Bloom, A.I.; Neeman, Z.; Floman, Y.; Gomori, J.; Bar-Ziv, J.

    1996-01-01

    The true incidence of fracture of the occipital condyles is unknown. It may be associated with instability at the craniocervical joint. CT is the modality of choice for the demonstration of these fractures, but its use for imaging of the associated ligament injury has not been reported. In order to demonstrate normal anatomy, occipital condyle fracture and ligament injury, and to estimate the incidence of this lesion, 21 children and young adults with high-energy blunt craniocervical injury were examined prospectively. Thin-slice, axial, contiguous, CT was performed from the base of C2 to above the foramen magnum. Bone and soft tissue windows and coronal, sagittal, and curvilinear 2D reconstructions were performed. Five occipital condyle fractures were identified in four patients (19 %), with demonstration of alar ligament injury in two cases and local hematoma in one. In four, artifacts or rotation precluded assessment of ligaments. In all remaining cases normal bone and ligament anatomy was demonstrated. Fracture of the occipital condyles following craniocervical injury is not uncommon in children and young adults. Normal bone and ligament anatomy and pathology can be safely and clearly demonstrated in seriously injured patients and others using this CT technique. Increased awareness of this entity and a low threshold for performing CT should avoid the potentially serious consequences of a missed diagnosis. (orig.). With 8 figs., 2 tabs

  17. CT identification of bronchopulmonary segments: 50 normal subjects

    International Nuclear Information System (INIS)

    Osbourne, D.; Vock, P.; Godwin, J.D.; Silverman, P.M.

    1984-01-01

    A systematic evaluation of the fissures, segmental bronchi and arteries, bronchopulmonary segments, and peripheral pulmonary parenchyma was made from computed tomographic (CT) scans of 50 patients with normal chest radiographs. Seventy percent of the segmental bronchi and 76% of the segmental arteries were identified. Arteries could be traced to their sixth- and seventh-order branches; their orientation to the plane of the CT section allowed gross identification and localization of bronchopulmonary segments

  18. Cine CT in the evaluation of coronary bypass graft patency

    International Nuclear Information System (INIS)

    Stanford, W.; Rooholamini, M.; Rumberger, J.; Marcus, M.; Hiratzka, L.

    1986-01-01

    Cine CT produces axial images over an 8-cm section of the aorta in 50 msec. This characteristic makes the technique useful for evaluating coronary bypass graft (CBG) patency. With the use of 40 ml of 67% iothalamate sodium injected via an antecubital vein, 28 patients with 68 CBGs underwent cine CT. Ten patients with 21 CBGs also underwent cardiac catheterization. In the latter group the overall accuracy of cine CT compared to cardiac catheterization was 95.2% (20/21). The sensitivity was 94.1% (16/17), and the specificity was 100% (4/4). This figure compares favorably with the 92% sensitivity achieved with conventional CT

  19. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  20. CT cystography

    International Nuclear Information System (INIS)

    Tsili, A.

    2012-01-01

    Full text: Cancer of the urinary bladder is one of the commonest urothelial neoplasms. Conventional cystoscopy remains the mainstay in the diagnosis of urinary bladder carcinomas. But it is an invasive and uncomfortable procedure, associated with complications. Computed tomographic (CT) virtual cystoscopy has been proposed as an alternative imaging modality with potential advantages in the detection of urinary bladder neoplasms and good patient acceptance. It is a minimally invasive technique, allowing imaging of the urinary bladder in multiple planes and a 360 0 view. CT cystoscopy provides information about the location, size and morphologic features of urinary bladder lesions, indicating appropriate areas for biopsy. It can be performed in cases in which conventional cystoscopy is not feasible, such as in the presence of urethral strictures, marked prostatic hypertrophy or active bleeding, and in cases in which cystoscopic findings are inconclusive. The technique can be used to evaluate areas of the urinary bladder difficult to evaluate with cystoscopy, such as the anterior bladder neck and narrowmouthed diverticula. Finally, virtual cystoscopy provides both intraluminal and extraluminal pathologic changes, so intravesical disease and exrtavesical extension can be evaluated in the same study. One of the limitations of this technique is the difficulty to demonstrate small-sized lesions. The introduction of multi-detector row CT (MDCT) scanners was a major technological advancement because among other things it substantially improves z-axis resolution by reducing section collimation and allowing the detection of very small lesions. The near isotropic or isotropic pixels achieved with a multidetector CT scanner, enable the creation of multiplanar reformatted images with a resolution very close to that of the axial images and three-dimensional (3D) renderings of outstanding quality. Transverse, multiplanar reformations and virtual endoscopic images are complementary

  1. Photon CT scanning of advanced ceramic materials

    International Nuclear Information System (INIS)

    Sawicka, B.D.; Ellingson, W.A.

    1987-02-01

    Advanced ceramic materials are being developed for high temperature applications in advanced heat engines and high temperature heat recovery systems. Small size flaws (10 - 200 μm) and small nonuniformities in density distributions (0.1 -2%) present as long-range density gradients, are critical in most ceramics and their detection is of crucial importance. Computed tomographic (CT) imaging provides a means of obtaining a precise two-dimensional density map of a cross section through an object from which accurate information about small flaws and small density gradients can be obtained. With the use of high energy photon sources high contrast CT images can be obtained for both low and high density ceramics. In the present paper we illustrate the applicability of the photon CT technique to the examination of advanced ceramics. CT images of sintered alumina tiles are presented from which data on high-density inclusions, cracks and density gradients have been extracted

  2. Data explosion: the challenge of multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Geoffrey D. E-mail: grubin@standford.edu

    2000-11-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.

  3. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  4. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  5. Fast and Automatic Ultrasound Simulation from CT Images

    Directory of Open Access Journals (Sweden)

    Weijian Cong

    2013-01-01

    Full Text Available Ultrasound is currently widely used in clinical diagnosis because of its fast and safe imaging principles. As the anatomical structures present in an ultrasound image are not as clear as CT or MRI. Physicians usually need advance clinical knowledge and experience to distinguish diseased tissues. Fast simulation of ultrasound provides a cost-effective way for the training and correlation of ultrasound and the anatomic structures. In this paper, a novel method is proposed for fast simulation of ultrasound from a CT image. A multiscale method is developed to enhance tubular structures so as to simulate the blood flow. The acoustic response of common tissues is generated by weighted integration of adjacent regions on the ultrasound propagation path in the CT image, from which parameters, including attenuation, reflection, scattering, and noise, are estimated simultaneously. The thin-plate spline interpolation method is employed to transform the simulation image between polar and rectangular coordinate systems. The Kaiser window function is utilized to produce integration and radial blurring effects of multiple transducer elements. Experimental results show that the developed method is very fast and effective, allowing realistic ultrasound to be fast generated. Given that the developed method is fully automatic, it can be utilized for ultrasound guided navigation in clinical practice and for training purpose.

  6. US-CT 3D dual imaging by mutual display of the same sections for depicting minor changes in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hiroyuki, E-mail: fukuhiro1962@hotmail.com [International HIFU Center, Sanmu Medical Center Hospital, Naruto 167, Sanbu-shi, Chiba 289-1326 (Japan); Ito, Ryu; Ohto, Masao; Sakamoto, Akio [International HIFU Center, Sanmu Medical Center Hospital, Naruto 167, Sanbu-shi, Chiba 289-1326 (Japan); Otsuka, Masayuki; Togawa, Akira; Miyazaki, Masaru [Department of General Surgery, Graduate School of Medicine, Chiba University, Inohana 1-8-1, Chuo-ku, Chiba-shi, Chiba 260-0856 (Japan); Yamagata, Hitoshi [Toshiba Medical Systems Corporation, Otawara 324-0036 (Japan)

    2012-09-15

    The purpose of this study was to evaluate the usefulness of ultrasound-computed tomography (US-CT) 3D dual imaging for the detection of small extranodular growths of hepatocellular carcinoma (HCC). The clinical and pathological profiles of 10 patients with single nodular type HCC with extranodular growth (extranodular growth) who underwent a hepatectomy were evaluated using two-dimensional (2D) ultrasonography (US), three-dimensional (3D) US, 3D computed tomography (CT) and 3D US-CT dual images. Raw 3D data was converted to DICOM (Digital Imaging and Communication in Medicine) data using Echo to CT (Toshiba Medical Systems Corp., Tokyo, Japan), and the 3D DICOM data was directly transferred to the image analysis system (ZioM900, ZIOSOFT Inc., Tokyo, Japan). By inputting the angle number (x, y, z) of the 3D CT volume data into the ZioM900, multiplanar reconstruction (MPR) images of the 3D CT data were displayed in a manner such that they resembled the conventional US images. Eleven extranodular growths were detected pathologically in 10 cases. 2D US was capable of depicting only 2 of the 11 extranodular growths. 3D CT was capable of depicting 4 of the 11 extranodular growths. On the other hand, 3D US was capable of depicting 10 of the 11 extranodular growths, and 3D US-CT dual images, which enable the dual analysis of the CT and US planes, revealed all 11 extranodular growths. In conclusion, US-CT 3D dual imaging may be useful for the detection of small extranodular growths.

  7. US-CT 3D dual imaging by mutual display of the same sections for depicting minor changes in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Fukuda, Hiroyuki; Ito, Ryu; Ohto, Masao; Sakamoto, Akio; Otsuka, Masayuki; Togawa, Akira; Miyazaki, Masaru; Yamagata, Hitoshi

    2012-01-01

    The purpose of this study was to evaluate the usefulness of ultrasound-computed tomography (US-CT) 3D dual imaging for the detection of small extranodular growths of hepatocellular carcinoma (HCC). The clinical and pathological profiles of 10 patients with single nodular type HCC with extranodular growth (extranodular growth) who underwent a hepatectomy were evaluated using two-dimensional (2D) ultrasonography (US), three-dimensional (3D) US, 3D computed tomography (CT) and 3D US-CT dual images. Raw 3D data was converted to DICOM (Digital Imaging and Communication in Medicine) data using Echo to CT (Toshiba Medical Systems Corp., Tokyo, Japan), and the 3D DICOM data was directly transferred to the image analysis system (ZioM900, ZIOSOFT Inc., Tokyo, Japan). By inputting the angle number (x, y, z) of the 3D CT volume data into the ZioM900, multiplanar reconstruction (MPR) images of the 3D CT data were displayed in a manner such that they resembled the conventional US images. Eleven extranodular growths were detected pathologically in 10 cases. 2D US was capable of depicting only 2 of the 11 extranodular growths. 3D CT was capable of depicting 4 of the 11 extranodular growths. On the other hand, 3D US was capable of depicting 10 of the 11 extranodular growths, and 3D US-CT dual images, which enable the dual analysis of the CT and US planes, revealed all 11 extranodular growths. In conclusion, US-CT 3D dual imaging may be useful for the detection of small extranodular growths

  8. Radiolucencies and cavitation in bronchioloalveolar carcinoma: CT-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gaeta, M.; Bartiromo, G. [Service of Diagnostic Imaging, Piemonte Hospital, Messina (Italy); Caruso, R. [Institute of Pathology, University of Messina (Italy); Blandino, A.; Scribano, E.; Pandolfo, I. [Institute of Radiologic Sciences, University of Messina (Italy)

    1999-02-01

    Bronchioloalveolar carcinoma (BAC) is a polymorphic lung cancer the incidence of which is rising. The presence of intratumoral radiolucencies is an important feature of bronchioloalveolar carcinoma.The aim of this study was to present pictorially the spectrum of intratumoral radiolucencies visible in BAC. In 57 BACs studied with thin-slice CT, we identified six types of radiolucencies: (a) patent intratumoral bronchioles (air bronchiologram); (b) pseudocavitations; (c) cavitation; (d) serpentine radiolucencies; (e) internal alveologram; and (f) multiple cystic lesions. (orig.) (orig.) With 12 figs., 13 refs.

  9. Measurements of computed tomography dose index for axial and spiral CT scanners

    International Nuclear Information System (INIS)

    Breiki, G; Abbas, Y.; Diab, H.M.; Gomaa, M

    2007-01-01

    The energy deposited in the patient by the rotating x-ray beam in computed tomography produces more uniform absorbed dose values within the section of imaged tissue than those produced in conventional radiological procedures. The dose values within a specific section are determined by factors such as voltage, current, scan field, rotation angle, filtration, collimation, and section thickness and spacing. This study is a part of extensive project, aiming to investigate practice of computed tomography at various hospitals and to implement a Reference Dose Levels (RDLs) to routine CT examinations in Egypt. The dosimetric quantities proposed in the European Guidelines (EG) for CT are weighted computed tomography dose index (CTDI w ) for a single slice and dose-length product (DLP) for a complete examination. Patient-related data as well as technical parameters for head, chest, abdomen and pelvis examinations were collected for seven CT scanners in public and private hospitals.Dose measurements were performed for both axial and spiral models for a range of CT examinations using CT dosimetry head and body phantoms, and ion chamber designed for CT dosimetry. The determined CTDI w and DLP values were compared with the European Commission reference dose levels (ECRDLs) and also with some international survey results. Mean values of CTDI w had a range of 36-69 m Gy with average 55 m Gy for head, and 11-35 mGy with average 23 mGy for chest, abdomen and pelvis examinations. The current reference CTDI w values are 60 m Gy for adult head and 25 m Gy for adult Abdomen

  10. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  11. Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis.

    Science.gov (United States)

    Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A

    2011-08-01

    To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.

  12. Spatial relationship between intrahepatic artery and portal vein based on the fusion image of CT-arterial portography (CTAP) and CT-angiography (CTA): New classification for hepatic artery at hepatic hilum and the segmentation of right anterior section of the liver

    International Nuclear Information System (INIS)

    Ibukuro, Kenji; Takeguchi, Takaya; Fukuda, Hozumi; Abe, Shoko; Tobe, Kimiko; Tanaka, Rei; Tagawa, Kazumi

    2012-01-01

    Purpose: To clarify the variations of the intrahepatic artery and portal vein and to verify the proper segmentation for the right anterior section of the liver. Materials and methods: CT during arterial portography and CT angiography were performed on 64-slice multi detector row CT in 147 patients. All images were transferred to a workstation for analysis using multi-image-fusion mode. We investigated the spatial relationship between hepatic artery and portal vein in the right hemiliver and the segmentation of the right anterior hepatic artery and portal vein. Results: The spatial anatomy of right hepatic arteries and portal vein was (1) anterior and posterior hepatic artery run superior and inferior to anterior portal vein, respectively (47.6%), (2) one anterior hepatic artery runs superior to and another one runs inferior to anterior portal vein (15%), (3) anterior and posterior hepatic arteries run superior to anterior portal vein (11.6%), (4) anterior and posterior hepatic arteries run inferior to anterior portal vein (7.5%), and (5) one posterior hepatic artery runs superior to and another one runs inferior to anterior portal vein (6.8%). The combined anatomy of right anterior artery and portal vein with regard to segmentation was classified as (1) dorso-ventral (26.5%), (2) dorso-ventral and inferior (10.9%), (3) multiple (18.4%), and (4) superior and inferior segments (1.4%). Conclusion: There are various types of spatial anatomy of intrahepatic artery and portal vein. The hepatic arteries as well as portal veins of right anterior section of the liver could be divided into dorsal and ventral, not superior and inferior.

  13. Nondestructive insights into composition of the sculpture of Egyptian Queen Nefertiti with CT.

    Science.gov (United States)

    Huppertz, Alexander; Wildung, Dietrich; Kemp, Barry J; Nentwig, Tanja; Asbach, Patrick; Rasche, Franz Maximilian; Hamm, Bernd

    2009-04-01

    To assess the conservation status of, to gain information on the creation of, and to provide surface reformations of the core and the surface of the bust of the pharaoh-queen Nefertiti, considered to be one of the greatest treasures of ancient Egyptian art, with computed tomography (CT). Multisection CT was performed with 0.6-mm section thickness. Two- and three-dimensional reformations were made to depict the core and the surface separately. The stucco layer on the face and the ears was very thin, a maximum of 1-2 mm thick. The rear part of the reconstructed crown showed two thick stucco layers of different attenuation values, indicating that a multistep process was used to create the sculpture. Within the stucco, a great number of air-equivalent hypoattenuating areas, filamentous fissures parallel to the surface, and an inhomogeneous bonding between the layers were delineated. Nefertiti's inner face was not anonymous, but rather delicately sculpted by the royal sculptor Thutmose. The comparison to the outer face revealed differences, including the angles of the eyelids, creases around the corners of the mouth on the limestone surface, and a slight bump on the ridge of the nose. According to the beauty ideals of the Amarna period, the differences had positive and negative effects and can be read as signs of individualization of the sculpture. The potential material-related weaknesses of the sculpture that were revealed at imaging necessitate careful handling, with the avoidance of any focal pressure and shearing forces in the crown and the shoulders. CT imaging revealed construction techniques in Nefertiti's bust that had implications for conservation, as well as for an understanding of the artistic methods used in the creation of this masterpiece of art of the 18th dynasty.

  14. Dental CT: examination technique, radiation load and anatomy

    International Nuclear Information System (INIS)

    Lenglinger, F.X.; Muhr, T.

    1999-01-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [de

  15. Intrathoracic kidney. Diagnostic value of CT scan imaging

    International Nuclear Information System (INIS)

    Baillet, A.M.; Escure, M.N.

    1988-01-01

    Two cases are reported of an ectopic right kidney that was partially intrathoracic in position. Diagnosis was simple from CT scan imaging appearances, the examination being performed to investigate an intrathoracic mass. Images showed a tissular mass within a fatty zone in sections without contrast and the typical appearance of the kidney on sections with contrast [fr

  16. Distortional Mechanics of Thin-Walled Structural Elements

    DEFF Research Database (Denmark)

    Andreassen, Michael Joachim

    In several industries such as civil, mechanical, and aerospace, thin-walled structures are often used due to the high strength and effective use of the materials. Because of the increased consumption there has been increasing focus on optimizing and more detailed calculations. However, finely...... number of degrees of freedom. This means that the classical Vlasov thin-walled beam theory for open and closed cross sections is generalized as part of a semi-discretization process by including distortional displacement fields. A novel finite-element-based displacement approach is used in combination...... by discretization of the cross section are now solved analytically and the formulation is valid without special attention and approximation also for closed single or multi-cell cross sections. Furthermore, the found eigenvalues have clear mechanical meaning, since they represent the attenuation of the distortional...

  17. Blunt trauma of bone structures of the chest--computed tomography vs multidetector computed tomography.

    Science.gov (United States)

    Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana

    2013-08-01

    Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  18. Changes in Cross-Sectional Area and Transverse Diameter of the Heart on Inspiratory and Expiratory Chest CT: Correlation with Changes in Lung Size and Influence on Cardiothoracic Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Hayato Tomita

    Full Text Available The aim of this study was to investigate physiological changes in cardiac area and diameters between inspiratory and expiratory chest computed tomography (CT, and to assess their correlation with lung size change and influence on cardiothoracic ratio (CTR measurements.The institutional review board of our institution approved this study, and informed consent was waived. Forty-three subjects underwent inspiratory and expiratory chest CT as part of routine clinical care. On both inspiratory and expiratory scans, lung volumes and maximum lung diameters (transverse and vertical directions were measured. The maximum cardiac cross-sectional area (CSA and the maximum transverse cardiac diameter were measured on both scans, and the CT-based CTR was calculated. Changes in the lung and cardiac measurements were expressed as the expiratory/inspiratory (E/I ratios. Comparisons between inspiratory and expiratory measurements were made by the Wilcoxon signed-rank test. Correlations between the E/I ratios of lung and heart measurements were evaluated by Spearman's rank correlation analysis.Cardiac CSA and transverse cardiac diameter was significantly larger on expiratory than on inspiratory CT (p < 0.0001. Significant negative correlations were found between the E/I ratios of these cardiac measurements and the E/I ratios of lung volume and vertical lung diameter (p < 0.01. CT-based CTR was significantly larger on expiration than on inspiration (p < 0.0001.Heart size on chest CT depends on the phase of ventilation, and is correlated with changes in lung volume and craniocaudal lung diameter. The CTR is also significantly influenced by ventilation.

  19. Semicircular canal dehiscence: Frequency and distribution on temporal bone CT and its relationship with the clinical outcomes

    International Nuclear Information System (INIS)

    Elmali, Muzaffer; Polat, Ahmet Veysel; Kucuk, Harun; Atmaca, Sinan; Aksoy, Ahmet

    2013-01-01

    Purpose: In this study, we aimed to investigate the frequency of SCD and its distribution and relationship with clinical outcomes on thin-section CT of the temporal bone. Materials and methods: Digital temporal bone CT images of 850 consecutive patients (1700 temporal bone CTs, 5100 SCs) who presented with a range of complaints such as vertigo, deafness, ear pain, fullness, and discharge between January 2008 and December 2011 were re-evaluated. Axial and oblique coronal reconstruction images of the temporal bone were made with a reconstruction thickness of 0.5 mm. Additionally, superior SC was evaluated in two perpendicular planes. Results: Out of 850 patients, 70 had completely normal temporal bone CT. Ninety-three patients had at least one SCD. In the temporal bone-based evaluation, 119 (26 bilateral, 67 unilateral) of 1700 temporal bones (7%) showed dehiscence. The SC-based evaluation revealed 125 SCD (2.5%) in 5100 SCs. The total number and rates of SCD were as follows: superior 103 (82.4%), posterior 13 (10.4%), and lateral nine (7.2%). Twenty of the 93 patients with SCD (21.5%) revealed no other findings on their temporal bone CTs. We determined a significant correlation between vestibular complaints, conductive hearing loss and SCD but there was no correlation between mixed, sensorineural hearing loss and SCD. Conclusion: We determined the frequency of SCD in 11% of patients and 7% of temporal bones. With regards to the distribution, the superior SC showed the highest dehiscence rate (82.4%). We found a significant correlation between vestibular symptoms, conductive hearing loss and SCD

  20. Semicircular canal dehiscence: Frequency and distribution on temporal bone CT and its relationship with the clinical outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Elmali, Muzaffer, E-mail: muzafel@yahoo.com.tr [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Polat, Ahmet Veysel, E-mail: veyselp@hotmail.com [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Kucuk, Harun, E-mail: hardrmd@yahoo.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Atmaca, Sinan, E-mail: sinanatmaca@yahoo.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Aksoy, Ahmet, E-mail: toxocara47@hotmail.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey)

    2013-10-01

    Purpose: In this study, we aimed to investigate the frequency of SCD and its distribution and relationship with clinical outcomes on thin-section CT of the temporal bone. Materials and methods: Digital temporal bone CT images of 850 consecutive patients (1700 temporal bone CTs, 5100 SCs) who presented with a range of complaints such as vertigo, deafness, ear pain, fullness, and discharge between January 2008 and December 2011 were re-evaluated. Axial and oblique coronal reconstruction images of the temporal bone were made with a reconstruction thickness of 0.5 mm. Additionally, superior SC was evaluated in two perpendicular planes. Results: Out of 850 patients, 70 had completely normal temporal bone CT. Ninety-three patients had at least one SCD. In the temporal bone-based evaluation, 119 (26 bilateral, 67 unilateral) of 1700 temporal bones (7%) showed dehiscence. The SC-based evaluation revealed 125 SCD (2.5%) in 5100 SCs. The total number and rates of SCD were as follows: superior 103 (82.4%), posterior 13 (10.4%), and lateral nine (7.2%). Twenty of the 93 patients with SCD (21.5%) revealed no other findings on their temporal bone CTs. We determined a significant correlation between vestibular complaints, conductive hearing loss and SCD but there was no correlation between mixed, sensorineural hearing loss and SCD. Conclusion: We determined the frequency of SCD in 11% of patients and 7% of temporal bones. With regards to the distribution, the superior SC showed the highest dehiscence rate (82.4%). We found a significant correlation between vestibular symptoms, conductive hearing loss and SCD.

  1. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  2. Atlas of axial, sagittal and coronal anatomy with CT and MRI

    International Nuclear Information System (INIS)

    Christoforidis, A.J.

    1988-01-01

    This book correlates CT scans and nuclear magnetic resonance images with cross sections of all parts of the body-head and neck, thorax, abdomen, male and female pelvis and extremities. Cross sections are fixed, and images are made from the sections to provide exact section-to-scan correlation. Shows all three cross-sectional axes. Includes selected pathologic cases to demonstrate technique

  3. 7 CFR 29.2438 - Thin Leaf (C Group).

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Thin Leaf (C Group). 29.2438 Section 29.2438... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.2438 Thin Leaf (C Group). This group consists of leaves... body than those of the B group, and show little or no ground injury. Choice- and fine-quality tobacco...

  4. Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull

    International Nuclear Information System (INIS)

    Kang, Bok Hee; Kim, Kee Deog; Park, Chang Seo

    2001-01-01

    To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0 TM . One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired test was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % imcongruence were also performed. I-Gn, N-Gn, N-A, N-Ns, B-A and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient γ was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrb R and L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrb R and L respectively. It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which and difficult to be located

  5. CT appearance of amiodarone-induced pneumonitis

    International Nuclear Information System (INIS)

    Nicholson, A.A.; Hayward, C.

    1989-01-01

    Basal peripheral pleuroparenchymal opacities are described on CT of early cryptogenic fibrosing alveolitis, asbestosis and bleomycin pneumonitis. These diseases may be caused by free radical effects on phospholipid metabolism causing cell wall damage. Amiodarone hydrochloride alters phospholipid synthesis metabolically. Amiodarone pneumonitis might be expected to show similar CT appearances. Sixteen patients who have developed new respiratory symptoms while taking amiodarone have been scanned prone and supine and at inspiration and expiration by means of a scanner with 2-mm sections at 1-cm intervals. All have been previously healthy nonsmokers with no relevant occupational history. Previous chest radiographs have been normal. Results are presented

  6. Micron-CT using quasi-monochromatic x-rays produced in micro-PIXE

    International Nuclear Information System (INIS)

    Ishii, K.

    2009-01-01

    In ion-atom collision, characteristic X-rays are intensively produced and can be considered as a monochromatic X-ray source. We apply this feature to X-ray CT. By using micro-beams, cross sectional images can be provided with a spatial resolution of about 1 μm. On the basis of this idea, we developed a micron-CT consisting of a micro-beam system and an X-ray CCD camera. A tube holding samples was rotated by a stepping motor and the transmission images of the sample were taken with characteristic K-X-rays of Ti (4.558 keV) produced by 3 MeV proton micro-beams. After image reconstruction, images of cross sections of small objects were obtained with a spatial resolution of 3 μm. Using an absorption edge, we can identify an element in a sample. It is expected that our micron-CT can provide cross sectional images of in-vivo cellular samples and can be applied to a wide range of researches in biology and medicine. (author)

  7. Cystic lymphangioma of the spleen: US-CT-MRI correlation

    Energy Technology Data Exchange (ETDEWEB)

    Bezzi, M.; Spinelli, A.; Pierleoni, M.; Andreoli, G.M. [Dept. of Radiology, University of Rome ' La Sapienza' (Italy)

    2001-07-01

    A case of a surgically confirmed cystic lymphangioma of the spleen is presented. Preoperative imaging consisted of US, contrast-enhanced CT and MRI, all showing a multiloculated lesion with small cystic cavities divided by thin septa, corresponding to dilated lymphatic spaces. Preoperative studies correlated well with the pathologic findings. Cystic lymphangioma of the spleen is a very rare condition and is usually solitary and asymptomatic. Large lymphangiomas may be an indication for splenectomy, since the risk of rupture is high even from minor abdominal trauma. Preoperative diagnosis may be achieved with correlated noninvasive imaging. (orig.)

  8. Clinical significance of temporal bone CT with regard to hearing preservation in acoustic neurinoma removal

    Energy Technology Data Exchange (ETDEWEB)

    Umezu, Hiromichi; Seki, Yojirou; Aiba, Tadashi

    1988-02-01

    Since Rand and Kurze discussed the possibility of the anatomic preservation of the cochlear nerve via the posterior fossa transmeatal approach for the acoustic neurinoma, there have been increasingly many reports on the preservation of cochlear nerve function. With recent advances in diagnostic tools, today's neurosurgeon is able to make an earlier and more precise diagnosis of acoustic neurinomas even when the patient has good hearing. If useful hearing is to be kept, the cochlear nerve and blood supply of the labyrinth have to be preserved. In addition, surgical entry into the labyrinth, upon the removal of the posterior wall of the internal auditory canal, must be avoided, since it is likely to result in permanent hearing loss. Because of its superior contrast and spatial resolution, thin-section and high-resolution computed tomography of the temporal bone has the great advantage of demonstrating the exact relationship of the internal auditory canal to the posterior semicircular canal, the vestibule, and the common crus. In this study, thin-section, high-resolution computed tomography of the temporal bone was performed in 11 cases of acoustic neurinoma pre- and postoperatively. At operation, the lateral limit of the bone removal of the posterior internal auditory canal was determined on the basis of preoperative computed tomography of the temporal bone. As a result, inadvertent entry into the labyrinth was avoided, and useful hearing was preserved in 8 cases. In order to preserve useful hearing following total tumor removal, it is essential to plan the operative strategy meticulously on the basis of the findings of the preoperative investigation, Including temporal bone CT.

  9. Colon distension and scan protocol for CT-colonography: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Thierry N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Haan, Margriet C. de, E-mail: m.c.dehaan@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Venema, Henk W., E-mail: h.w.venema@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Stoker, Jaap, E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands)

    2013-08-15

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension, automatic carbon dioxide insufflation should be performed, preferably via a thin, flexible catheter. Hyoscine butylbromide is – when available – the preferred spasmolytic agent because of the positive effect on insufflation and pain/burden and its low costs. Scans in two positions are required for adequate distension and high polyp sensitivity and decubitus position may be used as an alternative for patients unable to lie in prone position. The great intrinsic contrast between air or tagging and polyps allows the use of low radiation dose. Low-dose protocol without intravenous contrast should be used when extracolonic findings are deemed unimportant. In patients suspected for colorectal cancer, normal abdominal CT scan protocols and intravenous contrast should be used in supine position for the evaluation of extracolonic findings. Dose reduction can be obtained by lowering the tube current and/or voltage. Tube current modulation reduces the radiation dose (except in obese patients), and should be used when available. Iterative reconstructions is a promising dose reducing tool and dual-energy CT is currently evaluated for its applications in CT-colonography. This review also provides our institution's insufflation procedure and scan parameters.

  10. Bronchial morphometry in smokers: comparison with healthy subjects by using 3D CT

    International Nuclear Information System (INIS)

    Montaudon, Michel; Berger, Patrick; Marthan, Roger; Lederlin, Mathieu; Tunon-de-Lara, Jose Manuel; Laurent, Francois

    2009-01-01

    The assessment of airway dimensions in patients with airway disease by using computed tomography (CT) has been limited by the obliquity of bronchi, the ability to identify the bronchial generation, and the limited number of bronchial measurements. The aims of the present study were (i) to analyze cross-sectional bronchial dimensions after automatic orthogonal reconstruction of all visible bronchi on CT images, and (ii) to compare bronchial morphometry between smokers and nonsmokers. CT and pulmonary function tests were performed in 18 males separated into two groups: 9 nonsmokers and 9 smokers. Bronchial wall area (WA) and lumen area (LA) were assessed using dedicated 3D software able to provide accurate cross-sectional measurements of all visible bronchi on CT. WA/LA and WA/(WA+LA) ratios were computed and all parameters were compared between both groups. Smokers demonstrated greater WA, smaller LA, and consequently greater LA/WA and LA/(WA+LA) ratios than nonsmokers. These differences occurred downward starting at the fourth bronchial generation. 3D quantitative CT method is able to demonstrate significant changes in bronchial morphometry related to tobacco consumption. (orig.)

  11. The application of high-resolution CT in the visualization of the vestibular aqueduct (Meniere's disease) and labyrinthine otospongiosis

    International Nuclear Information System (INIS)

    Zonneveld, F.W.; Groot, J.A.M. de; Huizing, E.H.; Damsma, H.; Waes, P.F.G.M. van

    1984-01-01

    Ever since the introduction of temporal bone imaging by means of high-resolution CT, it appears that the combination of high spatial resolution, high density resolution and the freedom of patient positioning for scanning of optimal otological planes may play a unique role in the diagnosis and follow-up of a number of otological disorder. Two examples are described here. The first is the possibility of determining whether the vestibular aqueduct in idiopathic Meniere's disease is obliterated or not, and if so, whether it is a bony or a fibrous obliteration. Although the results are preliminary, there are indications that all three cathegories occur and that the efficacy of drainage of the endolymphatic sac can be evaluated prior to surgery. The second example is the possibility of outlining and quantifying the bone mineral loss in cases of labyrinthine otospongiosis. Preliminary studies have outlined that there is a relationship between the degree of decalcification and the severity of sensorineural hearing loss. These examples show high-resolution, thin-section multiplanar CT to have great potential in the diagnosis and treatment of otological disorders. This will become evident as the techniques that were used here are worked out in more detail and become more widely known. (orig.)

  12. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    International Nuclear Information System (INIS)

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan

    2007-01-01

    We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage. eliosis hepatis is an uncommon condition characterized by blood-filled cystic cavities in the liver. The clinical presentation is quite variable from an asymptomatic presentation to hepatic failure, portal hypertension or fatal intraabdominal hemorrhage. The exact incidence of intrahepatic or intraperitoneal hemorrhage by liver rupture has not been determined in the literature and these complications have been demonstrated only in the form of about 20 case reports. On angiography, peliosis hepatis can be suspected by multiple small contrast accumulations that become distinct during the parenchymal phase and are persistent during the venous phase. Examinations using multidetector CT (MDCT) scanners, which provide thin-section, contrast-enhanced dynamic images, are increasing nowadays. Thus, this entity has a better chance to be incidentally encountered and to be a diagnostic challenge to the radiologists. In this report, we present a case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture. We demonstrate the imaging findings with emphasis on the contrast-enhanced dynamic MDCT features as well as the clinical outcome after treatment

  13. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-02-15

    We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage. eliosis hepatis is an uncommon condition characterized by blood-filled cystic cavities in the liver. The clinical presentation is quite variable from an asymptomatic presentation to hepatic failure, portal hypertension or fatal intraabdominal hemorrhage. The exact incidence of intrahepatic or intraperitoneal hemorrhage by liver rupture has not been determined in the literature and these complications have been demonstrated only in the form of about 20 case reports. On angiography, peliosis hepatis can be suspected by multiple small contrast accumulations that become distinct during the parenchymal phase and are persistent during the venous phase. Examinations using multidetector CT (MDCT) scanners, which provide thin-section, contrast-enhanced dynamic images, are increasing nowadays. Thus, this entity has a better chance to be incidentally encountered and to be a diagnostic challenge to the radiologists. In this report, we present a case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture. We demonstrate the imaging findings with emphasis on the contrast-enhanced dynamic MDCT features as well as the clinical outcome after treatment.

  14. CT of maxillofacial injury

    International Nuclear Information System (INIS)

    DeLaPaz, R.; Brant-Zawadzki, M.; Rowe, L.D.

    1986-01-01

    Computed tomography has the ability to evaluate maxillofacial trauma quickly. The well-known contrast resolution capabilities of CT play a role in the usefulness of this modality. However, it is the image manipulation capability which is of singular advantage in these cases. The spatial resolution of computed tomography has matched that of conventional pluridirectional tomography in current generation equipment. Since a set of axial CT sections can be obtained with automatic table incrementation within 12 minutes, the information content per time of study ratio is improved over that of conventional tomography, despite the fact that image reformation requires extra time on the part of the radiologist. Radiation savings are significantly in favor of computed tomography as well. In the authors' experience, computed tomography is the primary diagnostic imaging modality used in the evaluation of complex facial trauma, after routine screening films are obtained

  15. New approach to lung cancer screening with helical volume CT

    International Nuclear Information System (INIS)

    Midorikawa, S.; Hashimoto, N.; Katakura, T.; Suzuki, K.

    1990-01-01

    This paper evaluates the relationship between reducing radiation dose to the patient and maintaining the clinical quality of the chest image in lung cancer screening by helical-volume CT (HVCT). The authors evaluated the changing relationship between radiation dose and clinical quality after changing the HVCY scanning conditions (such as stroke of patient transport and section thickness) as well as adding copper filters of various thickness and using high-voltage x-ray examination to complement CT examinations. The authors were able to reduce radiation dose by changing the HVCT scanning conditions (eg, stroke of 20 mm/sec, with a section thickness of 10 mm)

  16. MRI of head trauma. Serial changes and comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Osamu; Sato, Shuji; Suzuki, Takashi; Endo, Shunro; Takaku, Akira.

    1988-08-01

    Sequential changes in magnetic resonance imaging (MRI) were investigated in comparison with computed tomography (CT) in 31 cases of head trauma. Twenty-one of them were of acute head trauma; the first MRI study was performed within 48 hours after the accident. Forty-two intracranial lesions were observed in these cases on MRI. The other 10 cases were of chronic subdural hematoma, two cases of which had bilateral lesions. Fourteen lesions of acute head trauma and two lesions of chronic subdural hematoma were detected only by MRI. MRI was superior to CT for the detection of small contusions and thin extra-axial collections, especially those which were located near the bony structures. The abnormal lesions were visualized in MRI during a longer period than in CT. Because the signal intensity of a hematoma changed sequentially, the detection of brain edema was easier than that of a subarachnoid and parenchimal hemorrhage. Judging from this experience, it seems that careful attention should be taken in the diagnosis of hemorrhagic lesions. However, MRI was poor in tissue characterization because of the too-high tissue sensitivity. T/sub 2/-weight SE imaging was essentially sensitive and useful in the early stage.

  17. Recent technologic advances in multi-detector row cardiac CT.

    Science.gov (United States)

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  18. Case with high cervical intramedullary hemangioblastoma associated with arteriovenous fistula. CT with simultaneous intravenous and intrathecal injection of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takao; Shoji, Shin-ichi; Yanagisawa, Nobuo; Tada, Tsuyoshi; Kobayashi, Naoki

    1988-02-01

    A 34-year-old woman complained of right hemiparesis and pain in the right hand. Routine X-ray of the cervical portion failed to reveal abnormal findings. CT with intravenous contrast medium showed a large high-density mass in the spinal canal at the level of C2. Right vertebral angiography showed a hypervascular mass. With simultaneous intravenous and intrathecal injections of contrast medium, the tumor was shown as a moderately high-density area and the parenchyma of cord as a thin low-density area surrounding the tumor stain on CT. These CT appearances led to the final diagnosis of high cervical intramedullary hemangioblastoma associated with arteriovenous fistulae. Pathological findings are typical of hemangioblastoma. The usefulness of CT in detecting the localization of hypervascular spinal cord lesions is stressed. (Namekawa, K.).

  19. AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT.

    LENUS (Irish Health Repository)

    Zarb, Francis

    2010-01-01

    The purpose of this study is to investigate the relationships among cross-sectional diameters, weight and computed tomography (CT) dose descriptors (CTDI and DLP) to identify which is best used as a measure for the establishment of DRLs in CT. Data (gender, weight, cross-sectional diameters, dose descriptors) from 56 adult patients attending for either a CT examination of the abdomen or chest was obtained from two spiral CT units using automatic milliampere modulation. The AP diameter was demonstrated as the main contributing factor influencing the dose in CT (CTDI: r(2) = 0.269, p-value < or =0.001; DLP: r(2) = 0.260, p-value < or =0.001) since it has a greater correlation with radiation dose than body weight and can thus be its substitute in dose-reduction strategies and establishment of DRLs. The advantages of using the AP diameter are that it can easily be measured prior to scanning or retrospectively from previous CT images. However, further studies on the practicality of this approach are recommended.

  20. High-picture quality industrial CT scanner

    International Nuclear Information System (INIS)

    Shoji, Takao; Nishide, Akihiko; Fujii, Masashi.

    1989-01-01

    Industrial X-ray-CT-scanners, which provide cross-sectional images of a tested sample without destroying it, are attracting attention as a new nondestructive inspection device. In 1982, Toshiba commenced the development of industrial CT scanners, and introduced the 'TOSCANER' -3000 and-4000 series. Now, the state of the art 'TOSCANER'-20000 series of CT systems has been developed incorporating the latest computer tomography and image processing technology, such as the T9506 image processor. One of the advantages of this system is its applicability to a wide range of X-ray energy . The 'TOSCANER'-20000 series can be utilized for inspecting castings and other materials with relatively low-transparency to X-rays, as well as ceramics, composite materials and other materials with high X-ray transparency. A further feature of the new system is its high-picture quality, with a high-spatial resolution resulting from a pixel size of 0.2x0.2(mm). (author)

  1. Automated quantification of emphysema in CT studies of the lung

    International Nuclear Information System (INIS)

    Archer, D.C.; deKemp, R.A.; Coblentz, C.L.; Nahmias, C.

    1991-01-01

    Emphysema by definition is a pathologic diagnosis. Recently, in vivo quantification of emphysema from CT with point counting and with a GE 9800 CT scanner program called Density Mask has been described. These methods are laborious and time-consuming, making them unsuitable for screening. The propose of this paper is to create a screening test for emphysema. The authors developed a computer program that quantifies the amount of emphysema from standard CT-scans. The computer was programmed to recognize the lung edges on each section by identifying abrupt changes in CT numbers; grow regions within each lung to identify and separate the lungs from other structures; count regions of lung containing CT numbers measuring <-900 HU corresponding to areas of emphysema; and calculation the percentage of emphysema present from the volume of normal emphysematous lung. The programs were written in C and urn on a Sun 4/100 workstation

  2. Buccal transmucosal delivery of calcitonin in rabbits using thin-film composites.

    Science.gov (United States)

    Cui, Zhengrong; Mumper, Russell J

    2002-12-01

    Salmon Calcitonin (sCT) is used to treat hypercalcemia resulting from Paget's disease and osteoporosis. sCT is available either in a sterile injectable form or nasal spray. Alternative and more cost-effective dosage forms for the delivery of calcitonin are needed. We sought to deliver sCT transmucosally using a previously reported mucoadhesive bilayer thin-film composite (TFC) via the buccal route. Forty micrograms of salmon calcitonin (200-IU) was loaded on preformed TFCs. In vitro release of sCT from TFCs was monitored in phosphate-buffered saline (10 mM, pH 7.4) at 37degrees C. Female New Zealand White rabbits (n = 6) were dosed with 40 microg of sCT either by injection via the ear vein or by applying sCT-loaded TFCs directly on the buccal pouch. Blood was collected at various times, and the plasma sCT and calcium concentrations were quantified. WinNonlin was used to determine the relevant pharmacokinetic parameters. In vitro, over 80% of sCT was released from the TFCs within 240 min. Super Case-II transport was indicated as the primary release mechanism. Rabbits injected intravenously had C(max), Cls, Vss, and AUC(0-inf) values of 75.1 +/- 6.5 ng/mL, 20.7 +/- 3.3 mL/min, 637 +/- 141 mL, and 1925 +/- 237 ng*min/mL, respectively. Rabbits dosed via the buccal route had C(max) Cls, and AUC(0-400 min values of 4.6 +/- 1.6 ng/mL, 22.0 +/- 5.9 mL/min, and 842.9 +/- 209.7 ng*min/mL, respectively. The relative bioavailability for rabbits treated with the TFCs was 43.8 +/- 10.9% with a CV of 24.9%. The reductions in plasma calcium levels after administration of sCT by both the intravenous and buccal route were comparable. The TFCs effectively delivered therapeutically efficacious amounts of sCT across the buccal mucosa in rabbits.

  3. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Reichelt, Angela [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany)], E-mail: Reichelt.Angela@mh-hannover.de; Hoeper, Marius M. [Department of Respiratory Medicine, Hannover Medical School (Germany); Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany); Keberle, Marc [Department of Diagnostic Radiology and Nuclear Medicine, Bruederkrankenhaus St. Josef Paderborn (Germany)

    2009-07-15

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  4. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    International Nuclear Information System (INIS)

    Reichelt, Angela; Hoeper, Marius M.; Galanski, Michael; Keberle, Marc

    2009-01-01

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  5. Computer aided detection of ureteral stones in thin slice computed tomography volumes using Convolutional Neural Networks.

    Science.gov (United States)

    Längkvist, Martin; Jendeberg, Johan; Thunberg, Per; Loutfi, Amy; Lidén, Mats

    2018-06-01

    Computed tomography (CT) is the method of choice for diagnosing ureteral stones - kidney stones that obstruct the ureter. The purpose of this study is to develop a computer aided detection (CAD) algorithm for identifying a ureteral stone in thin slice CT volumes. The challenge in CAD for urinary stones lies in the similarity in shape and intensity of stones with non-stone structures and how to efficiently deal with large high-resolution CT volumes. We address these challenges by using a Convolutional Neural Network (CNN) that works directly on the high resolution CT volumes. The method is evaluated on a large data base of 465 clinically acquired high-resolution CT volumes of the urinary tract with labeling of ureteral stones performed by a radiologist. The best model using 2.5D input data and anatomical information achieved a sensitivity of 100% and an average of 2.68 false-positives per patient on a test set of 88 scans. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Present status and future view on virtual endoscopy. Depiction of minute lesions in the large intestine with CT colonography

    International Nuclear Information System (INIS)

    Sugino, Yoshinori

    2002-01-01

    CT colonography is a new imaging technique using helical CT. We studied the efficacy of CT colonoscopy in the detection of small polyps and depiction of superficial lesions. Concerning the detection of small polyps, we studied 54 patients with abnormality checked by barium enema. Conventional colonoscopy revealed 79 lesions (5 advanced carcinomas, 4 superficial-type adenomas and 70 polyps). CT colonography identified all 5 carcinomas, 3 of the 4 superficial lesions and 43 of the 45 polyps that were 0.5 cm or smaller in diameter, 18 of 22 polyps that were 0.6 to 0.9 cm, and all 3 polyps that were 1.0 cm or more in diameter. There were 92 false positive polyps that were 0.5 cm or smaller in diameter. On a superficial lesion, we could depict a superficial depressive type early colonic carcinoma 1.0 cm in diameter, using very thin-slice CT equipment. In conclusion, CT colonography has a high sensitivity for detection of small polyps and sufficient capability for depiction of superficial lesions. CT colonography may be suitable for screening examinations of the large intestine. (author)

  7. Estimation of diastolic filling pressure with cardiac CT in comparison with echocardiography using tissue doppler imaging: Determination of optimal CT reconstruction parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Sun; Suh, Jon; Lee, Heon [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of); Lee, Bora [Dept. of Biostatistics, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University Hospital Cheonan, Cheonan (Korea, Republic of); Lim, Hyun Kyung [Dept. of Radiology, Soonchunhyang University Hospital Seoul, Seoul (Korea, Republic of)

    2017-08-01

    To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′. Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm{sup 2}). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography. For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.

  8. Study of the External Hyphae of AMF in Understanding the Function to Contribution of P Sorption by Plants Using the Thin Section Method

    Directory of Open Access Journals (Sweden)

    Machfud Effendy

    2008-09-01

    Full Text Available The study of the external hyphae of AMF was conducted for getting data of the soil hyphae distribution from the observation using thin section preparation. The experiment was arranged in factorial fully randomized design. The first factors were dosages of P application: 0; 45; 90; 135; and 180 kg ha-1. The second factors were AMF spore inoculation: with inoculation and without inoculation. The observations were conducted to roots and shoots oven dried, absorption of P, P32- fertilizer and P31 from soil. The soil was separated from T-pots and to prepare for making the thin section of soil for observation to hyphae distribution at every 2 cm level. The experiment results showed that the prepared of thin section was documented at the 200 µm x 200 µm (= 40.000 µm2 dimension can be used for external hifas observation. In the 400 µm2 areas of soil without AMF inoculated has about 24 to 27 external hyphal, so at the 40.000 µm2 areas has 2.400 until 2.700 hyphae. The soil was AMF inoculated has 19 to 25 hyphae at 400 µm2 areas of soil, and in the 40.000 µm2 areas has 1.900 until 2.500 hyphae and the length of hyphae about 67-75 m g-1. The diameter hifas at soil without AMF inoculation about 8-10 µm, and at the soil with AMF inoculated has hyphae diameter about 8-11 µm, and the long of hyphae about 53-69 m g-1. The growth speed of hyphae about 0.74-0.89 m day-1 or about 0.031-0.035 m hour-1. The inoculated plant with AMF spore gave more in contribution to P32 fertilizer and soil P31 than that in uninoculated plant, but the yield of shoot and root oven dried was higher for plants without inoculated AMF spore. The inoculated soil with spore of AMF caused to sum of AMF spore and soil P availability was higher than that in uninoculated soil.

  9. Lung cancer mimicking lung abscess formation on CT images.

    Science.gov (United States)

    Taira, Naohiro; Kawabata, Tsutomu; Gabe, Atsushi; Ichi, Takaharu; Kushi, Kazuaki; Yohena, Tomofumi; Kawasaki, Hidenori; Yamashiro, Toshimitsu; Ishikawa, Kiyoshi

    2014-01-01

    Male, 64 FINAL DIAGNOSIS: Lung pleomorphic carcinoma Symptoms: Cough • fever - Clinical Procedure: - Specialty: Oncology. Unusual clinical course. The diagnosis of lung cancer is often made based on computed tomography (CT) image findings if it cannot be confirmed on pathological examinations, such as bronchoscopy. However, the CT image findings of cancerous lesions are similar to those of abscesses.We herein report a case of lung cancer that resembled a lung abscess on CT. We herein describe the case of 64-year-old male who was diagnosed with lung cancer using surgery. In this case, it was quite difficult to distinguish between the lung cancer and a lung abscess on CT images, and a lung abscess was initially suspected due to symptoms, such as fever and coughing, contrast-enhanced CT image findings showing a ring-enhancing mass in the right upper lobe and the patient's laboratory test results. However, a pathological diagnosis of lung cancer was confirmed according to the results of a rapid frozen section biopsy of the lesion. This case suggests that physicians should not suspect both a lung abscesses and malignancy in cases involving masses presenting as ring-enhancing lesions on contrast-enhanced CT.

  10. The clinical significance of temporal bone CT with regard to hearing preservation in acoustic neurinoma removal

    International Nuclear Information System (INIS)

    Umezu, Hiromichi; Seki, Yojirou; Aiba, Tadashi

    1988-01-01

    Since Rand and Kurze discussed the possibility of the anatomic preservation of the cochlear nerve via the posterior fossa transmeatal approach for the acoustic neurinoma, there have been increasingly many reports on the preservation of cochlear nerve function. With recent advances in diagnostic tools, today's neurosurgeon is able to make an earlier and more precise diagnosis of acoustic neurinomas even when the patient has good hearing. If useful hearing is to be kept, the cochlear nerve and blood supply of the labyrinth have to be preserved. In addition, surgical entry into the labyrinth, upon the removal of the posterior wall of the internal auditory canal, must be avoided, since it is likely to result in permanent hearing loss. Because of its superior contrast and spatial resolution, thin-section and high-resolution computed tomography of the temporal bone has the great advantage of demonstrating the exact relationship of the internal auditory canal to the posterior semicircular canal, the vestibule, and the common crus. In this study, thin-section, high-resolution computed tomography of the temporal bone was performed in 11 cases of acoustic neurinoma pre- and postoperatively. At operation, the lateral limit of the bone removal of the posterior internal auditory canal was determined on the basis of preoperative computed tomography of the temporal bone. As a result, inadvertent entry into the labyrinth was avoided, and useful hearing was preserved in 8 cases. In order to preserve useful hearing following total tumor removal, it is essential to plan the operative strategy meticulously on the basis of the findings of the preoperative investigation, Including temporal bone CT. (author)

  11. ToF-SIMS Parallel Imaging MS/MS of Lipid Species in Thin Tissue Sections.

    Science.gov (United States)

    Bruinen, Anne Lisa; Fisher, Gregory L; Heeren, Ron M A

    2017-01-01

    Unambiguous identification of detected species is essential in complex biomedical samples. To date, there are not many mass spectrometry imaging techniques that can provide both high spatial resolution and identification capabilities. A new and patented imaging tandem mass spectrometer, exploiting the unique characteristics of the nanoTOF II (Physical Electronics, USA) TOF-SIMS TRIFT instrument, was developed to address this.Tandem mass spectrometry is based on the selection of precursor ions from the full secondary ion spectrum (MS 1 ), followed by energetic activation and fragmentation, and collection of the fragment ions to obtain a tandem MS spectrum (MS 2 ). The PHI NanoTOF II mass spectrometer is equipped with a high-energy collision induced dissociation (CID) fragmentation cell as well as a second time-of-flight analyzer developed for simultaneous ToF-SIMS and tandem MS imaging experiments.We describe here the results of a ToF-SIMS imaging experiment on a thin tissue section of an infected zebrafish as a model organism for tuberculosis. The focus is on the obtained ion distribution plot of a fatty acid as well as its identification by tandem mass spectrometry.

  12. CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia

    International Nuclear Information System (INIS)

    Datir, A.; Connell, D.

    2010-01-01

    Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 injections. A technical success of 100% was achieved in all cases with accurate needle placement without any complications and all the patients tolerated the procedure well. Out of eight, three patients (37%) had complete relief of pain on the follow-up intervals up to 6 months. Three out of eight patients (37%), had partial relief of symptoms and a second repeat injection was given at the 3 month interval of the follow-up period. At the end of the 6-month follow-up period, six out of eight patients (75%) experienced symptomatic relief (four complete relief and two partial relief) without any additional resort to conventional pain management. Twenty-five percent (two out of eight) did not have any symptomatic improvement. The mean visual analogue score (VAS) pre-procedure was 8 (range 6-10) and had decreased to 2 (range 0-5) in six out of eight patients. Conclusion: CT can be used as an imaging method to identify the ganglion and guide the needle in ganglion impar blockade. The advantages of CT

  13. CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia

    Energy Technology Data Exchange (ETDEWEB)

    Datir, A., E-mail: apdatir@gmail.co [Jackson Memorial Hospital, Miami, FL (United States); Connell, D. [Royal National Orthopaedic Hospital NHS Trust, Stanmore, Middlesex (United Kingdom)

    2010-01-15

    Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 injections. A technical success of 100% was achieved in all cases with accurate needle placement without any complications and all the patients tolerated the procedure well. Out of eight, three patients (37%) had complete relief of pain on the follow-up intervals up to 6 months. Three out of eight patients (37%), had partial relief of symptoms and a second repeat injection was given at the 3 month interval of the follow-up period. At the end of the 6-month follow-up period, six out of eight patients (75%) experienced symptomatic relief (four complete relief and two partial relief) without any additional resort to conventional pain management. Twenty-five percent (two out of eight) did not have any symptomatic improvement. The mean visual analogue score (VAS) pre-procedure was 8 (range 6-10) and had decreased to 2 (range 0-5) in six out of eight patients. Conclusion: CT can be used as an imaging method to identify the ganglion and guide the needle in ganglion impar blockade. The advantages of CT

  14. The value of the 3D CT imaging in diagnosis of lumbar spondylolysis

    International Nuclear Information System (INIS)

    Krupski, W.; Paslawski, M.; Zlomaniec, J.; Fatyga, M.; Majcher, P.

    2003-01-01

    The frequent cause of a low back pain is the lumbar spondylolysis and the spondylolisthesis. The purpose of the study was to assess of the value of three-dimensional CT imaging in diagnosis of the lumbar spondylolysis. Material comprises of 22 patients complaining from low back pain in which lateral radiograms, axial CT scans, MPR and 3D reconstructions were performed. The presence of spondylolysis, spondylolisthesis, stenosis of the spinal canal and intervertebral foramens were assessed. The differences in diagnostic value between analysed imaging modalities in revealing spondylolysis, spondylolisthesis and narrowing of intervertebral foramens, were statistically highly significant. The highest sensitivity in recognition of these pathologies was observed in 3D reconstruction. The 3D reconstructions were also useful in an assessment of the spinal canal stenosis, revealing degenerative changes, but the increased number of diagnosed pathologies was not statistically significant comparing with axial CT section. Spondylolysis was diagnosed in 22 patients based on 3D reconstructions, in 14 patients on MPR reconstructions, in 18 patients on axial sections and only in 8 cases on lateral radiograms. Spondylolisthesis was visible on lateral radiograms in 21 patients, on axial scans in 12 patients, and in 22 cases, on both MPR and 3D reconstruction. The stenosis of the spinal canal was found on lateral radiograms in 2 patients, on MPR reconstruction in 4 cases, and in 7 patients on 3D reconstruction. The intervertebral foramen stenosis was present in 5 patients, based on MPR reconstruction and in 17, on spatial images. Spatial 3D CT reconstructions are superior to lateral radiograms, axial CT sections and MPR reconstruction in revealing spondylolysis, spondylolisthesis and stenosis of intervertebral foramens. They are useful in assessment of spinal canal narrowing and evaluation of degenerative changes. In our opinion 3D CT reconstruction projected from the inside of the

  15. CT guided stereotaxy based on scout view imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wester, K; Kjartansson, O; Bakke, S J

    1987-05-01

    A simple and inexpensive method for CT guided sterotaxy is described. The method requires no extra equipment in the interface between the computer tomograph and the stereotaxic frame, and could therefore easily be adopted in most neurosurgical units. With this method, information from the transaxial CT sections is transferred manually via the scout view image to the operation theater skull X-rays, and thereby to the stereotaxic frame. The method has proved to be sufficiently accurate for all current non-functional stereotaxic procedures in our department during 30 months of testing.

  16. CT guided stereotaxy based on scout view imaging

    International Nuclear Information System (INIS)

    Wester, K.; Kjartansson, O.; Bakke, S.J.; Rikshospitalet, Oslo

    1987-01-01

    A simple and inexpensive method for CT guided sterotaxy is described. The method requires no extra equipment in the interface between the computer tomograph and the stereotaxic frame, and could therefore easily be adopted in most neurosurgical units. With this method, information from the transaxial CT sections is transferred manually via the scout view image to the operation theater skull X-rays, and thereby to the stereotaxic frame. The method has proved to be sufficiently accurate for all current non-functional stereotaxic procedures in our department during 30 months of testing. (orig.)

  17. Comparison of transaxial source images and 3-plane, thin-slab maximal intensity projection images for the diagnosis of coronary artery stenosis with using ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Seo, Joon Beom; Do, Kyung Hyun

    2006-01-01

    We wanted to compare the transaxial source images with the optimized three plane, thin-slab maximum intensity projection (MIP) images from electrocardiographic (ECG)-gated cardiac CT for their ability to detect hemodynamically significant stenosis (HSS), and we did this by means of performing a receiver operating characteristic (ROC) analysis. Twenty-eight patients with a heart rate less than 66 beats per minute and who were undergoing both retrospective ECG-gated cardiac CT and conventional coronary angiography were included in this study. The contrast-enhanced CT scans were obtained with a collimation of 16 x 0.75-mm and a rotation time of 420 msec. The tranaxial images were reconstructed at the mid-diastolic phase with a 1-mm slice thickness and a 0.5-mm increment. Using the transaxial images, the slab MIP images were created with a 4-mm thickness and a 2-mm increment, and they covered the entire heart in the horizontal long axis (4 chamber view), in the vertical long axis (2 chamber view) and in the short axis. The transaxial images and MIP images were independently evaluated for their ability to detect HSS. Conventional coronary angiograms of the same study group served as the standard of reference. Four radiologists were requested to rank each image with using a five-point scale (1 = definitely negative, 2 = probably negative, 3 = indeterminate, 4 = probably positive, and 5 definitely positive) for the presence of HSS; the data were then interpreted using ROC analysis. There was no statistical difference in the area under the ROC curve between transaxial images and MIP images for the detection of HSS (0.8375 and 0.8708, respectively; ρ > 0.05). The mean reading time for the transaxial source images and the MIP images was 116 and 126.5 minutes, respectively. The diagnostic performance of the MIP images for detecting HSS of the coronary arteries is acceptable and this technique's ability to detect HSS is comparable to that of the transaxial source images

  18. X-ray, CT and MRI findings of synovial tuberculosis in joints

    International Nuclear Information System (INIS)

    Yu Jinghong; Tao Meili; You Zhuangzhi; Yu Huazhi

    2006-01-01

    Objective: To analyze the X-ray, CT and MRI findings of synovial tuberculosis, and to evaluate the role of MRI in diagnosing synovial tuberculosis. Methods: Fourteen cases of synovial tuberculosis comfirmed by operation and pathology were retrospectively analyzed and summarized. All patients were examined by MRI and X-ray, and CT scans were performed in 3 cases. Results: X-ray showed joint swelling (8 cases), articular space narrowing (7 cases), marginal joint erosions (4 cases), and periarticular osteoporosis (9 cases). The joint swelling was detected on CT in all 3 cases, and bony erosion and speckled sequestra were seen in 2 cases. MRI in all of patients showed joint swelling and synovial proliferation in different drgees, demonstrated as heterogeneously low signal on T 1 WI and slight high signal (7 cases) and obvious high signal (6 cases) on T 2 WI, and diffuse synovial proliferation was demonstrated as massive and nodular signal in 8 cases. Joint effusion was present in 7 cases as low signal on T 1 WI and high signal on T 2 WI. Osseous erosion lesions were seen in 7 cases, and intra-articular cartilage thinned, partly or mostly disappeared in 11 cases. Periarticular bone marrow edema was found in 7 cases. Conclusion: MRI was superior to X-ray and CT in the diagnosis and differential diagnosis of synovial tuberculosis. (authors)

  19. Characteristics of modified CT injector for JFT-2M

    Energy Technology Data Exchange (ETDEWEB)

    Fukumoto, N. [Himeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201 (Japan)]. E-mail: fukumoto@elct.eng.himeji-tech.ac.jp; Ogawa, H. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan); Nagata, M. [Himeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201 (Japan); Uyama, T. [Himeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201 (Japan); Shibata, T. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan); Kashiwa, Y. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan); Kusama, Y. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan)

    2004-10-01

    The HIT-CTI mark II compact toroid (CT) injector employed for the JFT-2M tokamak facility at the Japan Atomic Energy Research Institute (JAERI) has been upgraded to improve injection performance. The nozzle of the mark III injector now has a linear tube in place of the original focus cone to avoid rapid focus and deceleration, and the tapered outer electrode has been replaced with more gentle taper in the compression section in order to facilitate gradual compression. The dependence of CT velocity and electron density on poloidal bias flux and trigger time of CT acceleration have been investigated in the operable range of 70-230 km/s average CT velocity and electron density of 0.1-1.0 x 10{sup 22} m{sup -3} at an accelerator bank voltage of 25 kV. The operation window is broader than that of the mark II injector. Emission of a CT plasmoid from the injector, and transport to the flux conserver as a high-density spheromak magnetic structure have also been confirmed.

  20. Identification of dental root canals and their medial line from micro-CT and cone-beam CT records

    Directory of Open Access Journals (Sweden)

    Benyó Balázs

    2012-10-01

    Full Text Available Abstract Background Shape of the dental root canal is highly patient specific. Automated identification methods of the medial line of dental root canals and the reproduction of their 3D shape can be beneficial for planning endodontic interventions as severely curved root canals or multi-rooted teeth may pose treatment challenges. Accurate shape information of the root canals may also be used by manufacturers of endodontic instruments in order to make more efficient clinical tools. Method Novel image processing procedures dedicated to the automated detection of the medial axis of the root canal from dental micro-CT and cone-beam CT records are developed. For micro-CT, the 3D model of the root canal is built up from several hundred parallel cross sections, using image enhancement, histogram based fuzzy c-means clustering, center point detection in the segmented slice, three dimensional inner surface reconstruction, and potential field driven curve skeleton extraction in three dimensions. Cone-beam CT records are processed with image enhancement filters and fuzzy chain based regional segmentation, followed by the reconstruction of the root canal surface and detecting its skeleton via a mesh contraction algorithm. Results The proposed medial line identification and root canal detection algorithms are validated on clinical data sets. 25 micro-CT and 36 cone-beam-CT records are used in the validation procedure. The overall success rate of the automatic dental root canal identification was about 92% in both procedures. The algorithms proved to be accurate enough for endodontic therapy planning. Conclusions Accurate medial line identification and shape detection algorithms of dental root canal have been developed. Different procedures are defined for micro-CT and cone-beam CT records. The automated execution of the subsequent processing steps allows easy application of the algorithms in the dental care. The output data of the image processing procedures

  1. C-arm CT for planning and guidance of extrahepatic embolizations

    International Nuclear Information System (INIS)

    Wacker, F.K.; Meissner, O.A.; Meyer, B.C.

    2009-01-01

    Interventional radiological vascular embolizations are complex procedures that require exact imaging of the target region to facilitate safe and effective treatment. The purpose of this paper is to present the technique and feasibility of flat detector C-arm computed tomography (C-arm CT) for control and guidance of extrahepatic abdominal embolization procedures. C-arm CT images can provide important information on both vascular and cross-sectional anatomy of the target region, help in determining therapy endpoints and provide follow-up during and immediately after the abdominal interventions.The cases presented demonstrate that C-arm CT images are beneficial for abdominal embolization procedures and facilitate precise treatment. (orig.) [de

  2. Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves

    International Nuclear Information System (INIS)

    Yamazaki, Tadashi; Suzuki, Jun-ichi; Shimamoto, Ryoichi; Tsuji, Taeko; Ohmoto-Sekine, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Komatsu, Shuhei; Akahane, Masaaki; Ohtomo, Kuni

    2008-01-01

    Purpose: Hounsfield CT values across coronary CT angiograms constitute CT value-spatial profile curves. These CT profile curves are independent of window settings, and therefore, parameters derived from the curves can be used for objective anatomic analyses. Applicability of parameters derived from the curves to quantification of coronary in-stent patency has not yet been evaluated. Methods: Twenty-five CT value-spatial profile curves were delineated from 10 consecutive coronary stents to test correlation between the curve derived parameter (i.e., the minimum extreme value normalized by dividing by the maximum value of the curves obtained at neighboring outside of stents) and three intravascular ultrasound (IVUS) parameters. Results: Correlation coefficients between normalized minimum extreme value of CT value-spatial profile curves and three IVUS parameters (such as patent cross-sectional in-stent area, the percentage of patent cross-sectional in-stent area, and coronary artery intra-stent diameter) were 0.65 (p < 0.01), 0.44 (p < 0.05) and 0.51 (p < 0.05), respectively. Conclusions: CT parameters defined on Hounsfield CT value-spatial profile curves correlated significantly with IVUS parameters for quantitative coronary in-stent patency. A new approach with CT coronary angiography is therefore indicated for the noninvasive assessment of in-stent re-stenosis

  3. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT

    Energy Technology Data Exchange (ETDEWEB)

    Mascalchi, Mario; Diciotti, Stefano (Radiodiagnostic Section, Department of Clinical Physiopathology, University of Florence, Florence (Italy)), Email: m.mascalchi@dfc.unifi.it; Sverzellati, Nicola (Department of Radiology, University of Parma, Parma (Italy)); Camiciottoli, Gianna (Department of Critical Care, University of Florence, Florence (Italy)); Ciccotosto, Cesareo (Division of Radiology, Arezzo Hospital, Arezzo (Italy)); Falaschi, Fabio (Second Division of Radiology, Cisanello Hospital, Azienda Ospedaliero Universitaria Pisana, Pisa (Italy)); Zompatori, Maurizio (Department of Radiology, S Orsola Hospital of Bologna, University of Bologna, Bologna (Italy))

    2012-02-15

    Background. Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. Purpose. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Material and Methods. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 +- 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. Results. In three of six operator pairs and in one of two intra-operator pairs the Kendall t test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P < 0.001; r = 0.65-0.81). Conclusion. The inter- and intra-operator agreement of detailed assessment of emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent

  4. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT

    International Nuclear Information System (INIS)

    Mascalchi, Mario; Diciotti, Stefano; Sverzellati, Nicola; Camiciottoli, Gianna; Ciccotosto, Cesareo; Falaschi, Fabio; Zompatori, Maurizio

    2012-01-01

    Background. Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. Purpose. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Material and Methods. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 ± 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. Results. In three of six operator pairs and in one of two intra-operator pairs the Kendall t test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P < 0.001; r = 0.65-0.81). Conclusion. The inter- and intra-operator agreement of detailed assessment of emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent

  5. Low agreement of visual rating for detailed quantification of pulmonary emphysema in whole-lung CT.

    Science.gov (United States)

    Mascalchi, Mario; Diciotti, Stefano; Sverzellati, Nicola; Camiciottoli, Gianna; Ciccotosto, Cesareo; Falaschi, Fabio; Zompatori, Maurizio

    2012-02-01

    Multidetector spiral computed tomography (CT) has opened the possibility of quantitative evaluation of emphysema extent in the whole lung. Visual assessment can be used for such a purpose, but its reproducibility has not been established. To assess agreement of detailed assessment of pulmonary emphysema on whole-lung CT using a visual scale. Thirty patients with chronic obstructive pulmonary disease underwent whole-lung inspiratory CT. Four chest radiologists rated the same 22 ± 2 thin sections using a visual scale which defines a range of emphysema extent between 0 and 100. Two of them repeated the rating two months later. Inter- and intra-operator agreement was evaluated with the Bland and Altman method. In addition, the percentage of emphysema at -950 Hounsfield units in the whole lung was determined using fully automated commercially available software for 3D densitometry. In three of six operator pairs and in one of two intra-operator pairs the Kendall τ test showed a significant correlation between the difference and the average magnitude of visual scores. Among different operators the half-width of 95% limits of agreement (95% LoA) was wide ranging between a score of 14.2-27.7 for an average visual score of 20 and between 18.5-36.8 for an average visual score of 80. Within the same operator the half-width of 95% LoA ranged between a score of 10.9-21.0 for an average visual score of 20 and between 25.1-30.1 for an average visual score of 80. The visual scores of the four radiologists were correlated with the results of densitometry (P emphysema in the whole lung using a visual scale is low and decreases with increasing emphysema extent.

  6. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  7. Diagnosis of tumors of the pituitary region by two-plane CT scans

    International Nuclear Information System (INIS)

    Murata, Minoru; Inoue, Hiroshi; Misumi, Shuzo; Shimizu, Tsuneo; Tamura, Masaru

    1981-01-01

    Thirty five cases of tumors in the pituitary region were analysed by two-plane CT (ordinary sections and reverse sections) in order to obtain a more accurate image of the tumor and thus establish an appropriate indication for the subnasal transsphenoidal approach. The tumors of pituitary region were classified into six groups (types I-VI) according to their degree of extension and direction of growth. Small tumors such as types I and II were detected more clearly by the reverse section than by the ordinary section. In cases of large tumors (types III-VI) relation of the tumor to the surrounding structures such as the sphenoid sinus, third ventricle, lateral ventricule, middle fossa and brain stem was accurately demonstrated by the reverse section. In the differential diagnosis of tumors in the pituitary regions, tumors showing mixed density or slightly high density and widening of the anteroposterior diameter of the sella in the precontrast reverse section and homogeneous enhancement by infusion were likely to be pituitary adenomas. One third of the pituitary adenomas showed ring-like high density in the post-contrast reverse section. Calcification was not seen in the pituitary adenomas by CT scans. All craniopharyngiomas belonged to types III-VI. Craniopharyngiomas showed high and/or low density, and various degrees of calcification in plain CT scans. Ring-like high density was seen in two thirds of the craniopharyngiomas. About one third of the craniopharyngiomas showed widening of the antero-posterior diameter of the sella. (J.P.N.)

  8. An application of dynamic CT for diagnosis of abnormal external ocular muscle movement

    International Nuclear Information System (INIS)

    Tomita, Kazumi; Ogura, Yuuko; Takeshita, Gen; Koga, Sukehiko; Katada, Kazuhiro; Anno, Hirofumi.

    1993-01-01

    To evaluate the movements of retrobulbar structures radiologically, we have developed a new technique called 'external ocular muscle movement CT' (EOM CT), in which dynamic CT scanning is performed while the patient performs controlled eye movements. This new technique was applied in one volunteer and 72 patients with external ophthalmoplegia due to orbital mass lesion, hyperthyroid ophthalmopathy, blowout fracture, and other retrobulbar lesions. EOM CT permits the assessment of extraocular muscle contraction in cases of blowout fracture, the evaluation of muscular contraction in hypertrophy of the extraocular muscles, and the diagnosis of adhesions between the extraocular muscles and intraorbital masses. Radiation dose to the lens from EOM CT was measured using a phantom and TLD, and was compared with that of conventional CT scanning with a 5 mm slice thickness. The dose to the lens from EOM CT was three times higher than that for conventional CT in axial scanning, but in the coronal section of the retrobulbar region, the dose to the lens from EOM CT decreases to one twelfth of that of conventional CT. EOM CT promises to be a powerful modality for functional evaluation of the extraocular muscles and other retrobulbar structures. (author)

  9. How to reduce nephropathy following contrast-enhanced CT: A lesson in policy implementation

    International Nuclear Information System (INIS)

    Richenberg, J.

    2012-01-01

    In excess of 50 contrast-enhanced computed tomography (CT) examinations are typically undertaken in our tertiary hospital NHS Trust each weekday, approximately 13,000 each year. In the Department of Radiology alone, we inject more than 1300 l of iodinated contrast medium per annum. There is a real need to devise a policy to anticipate contrast medium-induced nephropathy (CIN) and minimize its effects, without disrupting the high-intensity CT service. Having written a comprehensive yet pragmatic policy to reduce the incidence of this iatrogenic condition, it seemed sensible to share it with the wider radiology community and share the experience and lessons learnt in engaging all the stakeholders, ushering in the change with as little fuss as possible. The ramifications on primary and secondary care had to be anticipated, resource implications managed, and staff trained. This review is therefore presented in four sections: framing the problem, assessing its size and nature; a succeeding section on the available guidelines and their uptake; the policy itself to reduce CIN in CT is presented in the third section; and crucially, a description of the policy introduction process in the last section.

  10. Comparative Three-Dimensional Morphology of Baleen: Cross-Sectional Profiles and Volume Measurements Using CT Images.

    Science.gov (United States)

    Jensen, Megan M; Saladrigas, Amalia H; Goldbogen, Jeremy A

    2017-11-01

    Baleen whales are obligate filter feeders, straining prey-laden seawater through racks of keratinized baleen plates. Despite the importance of baleen to the ecology and natural history of these animals, relatively little work has been done on baleen morphology, particularly with regard to the three-dimensional morphology and structure of baleen. We used computed tomography (CT) scanning to take 3D images of six baleen specimens representing five species, including three complete racks. With these images, we described the three-dimensional shape of the baleen plates using cross-sectional profiles from within the gum tissue to the tip of the plates. We also measured the percentage of each specimen that was composed of either keratinized plate material or was void space between baleen plates, and thus available for seawater flow. Baleen plates have a complex three-dimensional structure with curvature that varies across the anterior-posterior, proximal-distal, and medial-lateral (lingual-labial) axes. These curvatures also vary with location along the baleen rack, and between species. Cross-sectional profiles resemble backwards-facing airfoils, and some specimens display S-shaped, or reflexed, camber. Within a baleen specimen, the intra-baleen void volume correlates with the average bristle diameter for a species, suggesting that essentially, thinner plates (with more space between them for flow) have thinner bristles. Both plate curvature and the relative proportions of plate and void volumes are likely to have implications for the mechanics of mysticete filtration, and future studies are needed to determine the particular functions of these morphological characters. Anat Rec, 300:1942-1952, 2017. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.

  11. Anomalous vessel in the middle ear: the role of CT and MR angiography

    International Nuclear Information System (INIS)

    Caldas, J.G.M.P.; Iffenecker, C.; Lasjaunias, P.; Doyon, D.; Attal, P.

    1998-01-01

    An 8-year-old child was examined because of conductive hearing loss with a retrotympanic mass on otoscopy. CT and MR angiography showed a large inferior tympanic artery traversing the hypotympanum and joining a thin, irregular internal carotid artery with a normal middle meningeal artery. These investigations, coupled with knowledge of the embryological development allowed a diagnosis of a complex vascular anomaly in the middle ear and avoided potential surgical complications. (orig.)

  12. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  13. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  14. Adaptive wiener filter based on Gaussian mixture distribution model for denoising chest X-ray CT image

    International Nuclear Information System (INIS)

    Tabuchi, Motohiro; Yamane, Nobumoto; Morikawa, Yoshitaka

    2008-01-01

    In recent decades, X-ray CT imaging has become more important as a result of its high-resolution performance. However, it is well known that the X-ray dose is insufficient in the techniques that use low-dose imaging in health screening or thin-slice imaging in work-up. Therefore, the degradation of CT images caused by the streak artifact frequently becomes problematic. In this study, we applied a Wiener filter (WF) using the universal Gaussian mixture distribution model (UNI-GMM) as a statistical model to remove streak artifact. In designing the WF, it is necessary to estimate the statistical model and the precise co-variances of the original image. In the proposed method, we obtained a variety of chest X-ray CT images using a phantom simulating a chest organ, and we estimated the statistical information using the images for training. The results of simulation showed that it is possible to fit the UNI-GMM to the chest X-ray CT images and reduce the specific noise. (author)

  15. Three-dimensional anatomical evaluation of bronchial artery with CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Xiao Xiangsheng; Liu Shiyuan; Li Chengzhou; Tao Xiaofeng

    2006-01-01

    Objective: To evaluate the ability of CT angiography in identifying and demonstrating the origins and courses of bronchial arteries by using the three-dimensional reformation technique. Methods Four hundred and forty-three eases were examined with thin-section enhanced MSCT. Three-dimensional images of bronchial arteries were processed at the workstation. Spatial anatomical characters of the bronchial arteries using volume rendering(VR), muhiplanar reconstruction (MPR), and maxium intensity projection (MIP) were observed. Results: At least one bronchial artery was clearly displayed in VR in 359 eases. The right bronchial arteries mainly appeared to originate from the right intercostal artery (213/436, 48.85% ) and descending aorta (207/436, 47.48%), while the left bronchial arteries mainly from the descending aorta (363/371, 97.84%). The right bronchial arteries of the descending aorta were mainly arised from fight wall (95/207, 45.89%), and then the anterior wall (88/207, 42.51%), while the left bronchial arteries of the descending aorta mainly arised from anterior wall of the aorta (272/363, 74.93%). The common trunk originated from the descending aorta mainly positioned in the anterior wall (57/77, 74.03%). 49.31% (215/436) of the fight bronchial arteries were coursing across the posterior edge of the right main bronchi, 35.55% (155/436) coursing the inferior edge, while 60.11% (223/371) of left bronchial arteries coursing forward across the superior edger of the left main bronchi, the others coursing the inferior or the posterior edge. There were eleven bronchial artery distribution patterns, with the right and left ones predominating (192/359, 53.48%), and then two right and one left (63/359, 17.55%). Conclusion: The bronchial artery anatomy was complicated, and CT angiography could clearly visualize the features. (authors)

  16. Dual energy CT iodine map for delineating inflammation of inflammatory arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Takeshi; Fukuda, Kunihiko [The Jikei University School of Medicine, Department of Radiology, Tokyo (Japan); Umezawa, Yoshinori; Asahina, Akihiko; Nakagawa, Hidemi [The Jikei University School of Medicine, Department of Dermatology, Tokyo (Japan); Furuya, Kazuhiro [The Jikei University School of Medicine, Division of Rheumatology Department of Internal Medicine, Tokyo (Japan)

    2017-12-15

    Iodine mapping is an image-processing technique used with dual-energy computed tomography (DECT) to improve iodine contrast resolution. CT, because of its high spatial resolution and thin slice reconstruction, is well suited to the evaluation of the peripheral joints. Recent developments in the treatment of inflammatory arthritis that require early diagnosis and precise therapeutic assessment encourage radiological evaluation. To facilitate such assessment, we describe DECT iodine mapping as a novel modality for evaluating rheumatoid arthritis and psoriatic arthritis of the hands and feet. (orig.)

  17. Uniaxially oriented polycrystalline thin films and air-stable n-type transistors based on donor-acceptor semiconductor (diC8BTBT)(FnTCNQ) [n = 0, 2, 4

    Science.gov (United States)

    Shibata, Yosei; Tsutsumi, Jun'ya; Matsuoka, Satoshi; Matsubara, Koji; Yoshida, Yuji; Chikamatsu, Masayuki; Hasegawa, Tatsuo

    2015-04-01

    We report the fabrication of high quality thin films for semiconducting organic donor-acceptor charge-transfer (CT) compounds, (diC8BTBT)(FnTCNQ) (diC8BTBT = 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene and FnTCNQ [n = 0,2,4] = fluorinated derivatives of 7,7,8,8,-tetracyanoquinodimethane), which have a high degree of layered crystallinity. Single-phase and uniaxially oriented polycrystalline thin films of the compounds were obtained by co-evaporation of the component donor and acceptor molecules. Organic thin-film transistors (OTFTs) fabricated with the compound films exhibited n-type field-effect characteristics, showing a mobility of 6.9 × 10-2 cm2/V s, an on/off ratio of 106, a sub-threshold swing of 0.8 V/dec, and an excellent stability in air. We discuss the suitability of strong intermolecular donor-acceptor interaction and the narrow CT gap nature in compounds for stable n-type OTFT operation.

  18. Hydro-CT in the detection and staging of pancreatic carcinoma

    International Nuclear Information System (INIS)

    Richter, G.M.; Wunsch, C.; Schneider, B.; Duex, M.; Kauffmann, G.W.; Klar, E.; Seelos, R.

    1998-01-01

    Purpose: To document our experience with spiral hydro-CT of the pancreas based on a combination of pharmacologic intestinal paralysis and water distension of the stomach and duodenum with specific reference to tumor detection rate, differentiation of malignant versus benign tumors and assessment of tumor resectability in a prospective study on 211 consecutive patients. Results: 96% of the examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to the contrast medium was seen. The prevalence of a pancreatic neoplasm was 37,8%. In tumor detection Hydro-CT reached an overall accuracy of 94,8% with a sensitivity of 93,7% and a specificity of 95,2%. 52 patients underwent surgical exploration 34 of whom with tumorfree resection margins (RO resection) corresponding to a resection of 42,5%. In those assessment of resectability reached an overall accuracy of 94,6% with a sensitivity of 91,2% and specificity of 95,6%. Conclusion: The new technique of Hydro-CT based on thin slice and spiral methodology including pharmacologic intestinal paralysis and water distension results in a high tumor detection rate and reliable assessment of resectability. (orig./AJ) [de

  19. Pericardial sinuses and recesses effusion of 16-slice helical CT imaging and anatomic correlation

    International Nuclear Information System (INIS)

    Lu Chunyan; Yang Zhigang; Zhou Xiangping; Yu Jianqun; Zhu Jie; Yang Kaiqing

    2007-01-01

    Objective: To evaluate the CT features and implications of the pericardial sinuses and recesses effusion by combining the sectional cadavers and 16 multi-slice CT (MSCT) reformation. Methods: The anatomy and communication of the pericardial sinuses and recesses on the axial, coronal and saggital sectional cadavers (respectively 1 case), and the morphologic features on MSCT reformatted images in 104 patients were observed. The detection rate of effusion was analyzed. Results: The sectional cadavers and CT images showed that the pericardial sinuses and recesses were formed by the reflections of the pericardium on the root of the great vessels. The detection rate of the sinuses and recesses was lower in small effusion than in moderate and large effusion (P<0.05). The superior aortic recess was the most common recess for pericardial effusion. Conclusion: The MSCT reformatted images can show the morphologic features of pericardial sinuses and recesses effusion and communications with the pericardial cavity, help differentiate pericardial effusion from other mediastinal or pericardial lesions. (authors)

  20. Longitudinal micro-CT as an outcome measure of interstitial lung disease in TNF-transgenic mice.

    Directory of Open Access Journals (Sweden)

    Richard D Bell

    Full Text Available Rheumatoid arthritis associated interstitial lung disease (RA-ILD is a debilitating condition with poor survival prognosis. High resolution computed tomography (CT is a common clinical tool to diagnose RA-ILD, and is increasingly being adopted in pre-clinical studies. However, murine models recapitulating RA-ILD are lacking, and CT outcomes for inflammatory lung disease have yet to be formally validated. To address this, we validate μCT outcomes for ILD in the tumor necrosis factor transgenic (TNF-Tg mouse model of RA.Cross sectional μCT was performed on cohorts of male TNF-Tg mice and their WT littermates at 3, 4, 5.5 and 12 months of age (n = 4-6. Lung μCT outcomes measures were determined by segmentation of the μCT datasets to generate Aerated and Tissue volumes. After each scan, lungs were obtained for histopathology and 3 sections stained with hematoxylin and eosin. Automated histomorphometry was performed to quantify the tissue area (nuclei, cytoplasm, and extracellular matrix and aerated area (white space within the tissue sections. Spearman's correlation coefficients were used to evaluate the extent of association between μCT imaging and histopathology endpoints.TNF-Tg mice had significantly greater tissue volume, total lung volume and mean intensity at all timepoints compared to age matched WT littermates. Histomorphometry also demonstrated a significant increase in tissue area at 3, 4, and 5.5 months of age in TNF-Tg mice. Lung tissue volume was correlated with lung tissue area (ρ = 0.81, p<0.0001, and normalize lung aerated volume was correlated with normalized lung air area (ρ = 0.73, p<0.0001.We have validated in vivo μCT as a quantitative biomarker of ILD in mice. Further, development of longitudinal measures is critical for dissecting pathologic progression of ILD, and μCT is a useful non-invasive method to study lung inflammation in the TNF-Tg mouse model.

  1. Quantitative imaging of excised osteoarthritic cartilage using spectral CT

    Energy Technology Data Exchange (ETDEWEB)

    Rajendran, Kishore; Bateman, Christopher J.; Younis, Raja Aamir; De Ruiter, Niels J.A.; Ramyar, Mohsen; Anderson, Nigel G. [University of Otago - Christchurch, Department of Radiology, Christchurch (New Zealand); Loebker, Caroline [University of Otago, Christchurch Regenerative Medicine and Tissue Engineering Group, Department of Orthopaedic Surgery and Musculoskeletal Medicine, Christchurch (New Zealand); University of Twente, Department of Developmental BioEngineering, Enschede (Netherlands); Schon, Benjamin S.; Hooper, Gary J.; Woodfield, Tim B.F. [University of Otago, Christchurch Regenerative Medicine and Tissue Engineering Group, Department of Orthopaedic Surgery and Musculoskeletal Medicine, Christchurch (New Zealand); Chernoglazov, Alex I. [University of Canterbury, Human Interface Technology Laboratory New Zealand, Christchurch (New Zealand); Butler, Anthony P.H. [University of Otago - Christchurch, Department of Radiology, Christchurch (New Zealand); European Organisation for Nuclear Research (CERN), Geneva (Switzerland); MARS Bioimaging, Christchurch (New Zealand)

    2017-01-15

    To quantify iodine uptake in articular cartilage as a marker of glycosaminoglycan (GAG) content using multi-energy spectral CT. We incubated a 25-mm strip of excised osteoarthritic human tibial plateau in 50 % ionic iodine contrast and imaged it using a small-animal spectral scanner with a cadmium telluride photon-processing detector to quantify the iodine through the thickness of the articular cartilage. We imaged both spectroscopic phantoms and osteoarthritic tibial plateau samples. The iodine distribution as an inverse marker of GAG content was presented in the form of 2D and 3D images after applying a basis material decomposition technique to separate iodine in cartilage from bone. We compared this result with a histological section stained for GAG. The iodine in cartilage could be distinguished from subchondral bone and quantified using multi-energy CT. The articular cartilage showed variation in iodine concentration throughout its thickness which appeared to be inversely related to GAG distribution observed in histological sections. Multi-energy CT can quantify ionic iodine contrast (as a marker of GAG content) within articular cartilage and distinguish it from bone by exploiting the energy-specific attenuation profiles of the associated materials. (orig.)

  2. Differences in MRI findings in cases showing ring-enhancement on a CT scan

    International Nuclear Information System (INIS)

    Tokiwa, Kaichi; Hashimoto, Takashi; Miyasaka, Yoshio; Yada, Kenzoh; Kan, Shinichi; Takagi, Hiroshi.

    1990-01-01

    It is sometimes difficult to differentiate between a brain abscess and a tumor, for both show ring-enhancement on a CT scan. The present authors have studied the benefit of MRI for the differential diagnosis of these two lesions. The subjects of this study were 6 cases of brain abscess and 10 cases of brain tumor, all of them showing ring-enhancement on a CT scan. The MRI findings were compared with those of the CT scan taken at almost the same time, especially focussing on the difference in the ring-enhancement. In 5 out of the 6 cases of brain abscess, T 2 -weighted MRI demonstrated a comparatively thin and homogeneous low-intensity, round rim. In the cases of brain tumor, however, none of the cases demonstrated this typical low-intensity, round rim; rather, in them the rim was thick and irregular. The authors can conclude that those MRI findings can serve as important differential diagnostic findings between brain abscess and tumor; also, MRI may be used as a landmark for terminating the administration of antibiotics in cases of brain abscess. (author)

  3. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zeniya, T.; Takeda, T. E-mail: ttakeda@md.tsukuba.ac.jp; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T

    2001-07-21

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  4. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Science.gov (United States)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  5. CT findings in recurrent pyogenic cholangitis

    International Nuclear Information System (INIS)

    Jung, Seung Hye; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho

    1991-01-01

    Recurrent pyogenic cholangitis is characterized clinically by recurrent attacks of right upper abdominal pain, fever and jaundice, and pathologically by chronic inflammation of the bile ducts with or without pigment bile duct stones. We analyzed the CT findings of 33 cases with recurrent pyogenic cholangitis. Twenty-four cases were confirmed by operation, and 9 cases were diagnosed clinically and cholangiographically. The CT findings of recurrent pyogenic cholangitis were dilatation of the intrahepatic ducts (n = 30), dilatation of the extrahepatic ducts (n = 24) intrahepatic stones (n = 16), extrahepatic stones (n = 12), stricture of the bile ducts (n = 10), wall enhancement of the bile ducts (n = 8), gallstones (n = 8), segmental atrophy of the liver (n = 7), pneumobilia (n = 4), abscess (n = 3), and segmental enhancement (n = 1) of the liver. A CT is considered helpful when sectional imaging is needed, but sonographic findings are equivocal or not confirmative; space-occupying lesions complicated with recurrent pyogenic cholangitis: hepatic resection is planned; and imaging guidance is needed for complex drainage procedures

  6. The role of hybrid SPECT-CT in oncology: current and emerging clinical applications

    International Nuclear Information System (INIS)

    Chowdhury, F.U.; Scarsbrook, A.F.

    2008-01-01

    Single photon emission computed tomography - computed tomography (SPECT-CT) is an emerging dual-modality imaging technique with many established and potential clinical applications in the field of oncology. To date, there has been a considerable emphasis on the benefits of integrated positron emission tomography - computed tomography (PET-CT) in oncology, but relatively little focus on the clinical utility of SPECT-CT. As with PET-CT, accurate co-registration of anatomical and functional data from a combined SPECT-CT camera often provides complementary diagnostic information. Both sensitivity (superior disease localization) and specificity (exclusion of false-positives due to physiological tracer uptake) are improved, and the functional significance of indeterminate lesions detected on cross-sectional imaging can be defined. This article will review the scope of hybrid SPECT-CT in oncology and illustrate both current and emerging clinical applications

  7. Cryogenic Yb: YAG Thin-Disk Laser

    Science.gov (United States)

    2016-09-09

    as a 4- level laser. Its absorption and emission cross-sections increase, and its thermal conductivity improves. Yb:YAG thin disk laser performance...Air Force Base, NM USA 87117 4RINI Technologies, 582 South Econ Circle, Oviedo, FL USA 32765 Keywords: Laser materials; Lasers, ytterbium...temperatures, Yb:YAG behaves as a 4- level laser. Its absorption and emission cross-sections increase, and its thermal conductivity improves. Yb:YAG

  8. The Appendix on CT

    Energy Technology Data Exchange (ETDEWEB)

    Whitley, S. [Sunnybrook Health Sciences Center, Toronto, Ontario (Canada); Barts and the Royal London, Royal London Hospital, Whitechapel, London (United Kingdom)], E-mail: siobhanwhitley@yahoo.co.uk; Sookur, P.; McLean, A.; Power, N. [Barts and the Royal London, Royal London Hospital, Whitechapel, London (United Kingdom)

    2009-02-15

    Appendicitis can be a difficult clinical diagnosis to make. A negative appendicectomy rate of 20% has traditionally been accepted as the consequences of appendiceal perforation can be grave. Cross-sectional imaging is increasingly being employed in the investigation of adults with suspected appendicitis. This review will demonstrate the appearance of the normal appendix on computed tomography (CT) and its appearance in a range of inflammatory and neoplastic processes including appendicitis, Crohn's disease, infections, and benign and malignant tumour000.

  9. A study of parameters in spiral CT volumetry using balloon phantoms

    International Nuclear Information System (INIS)

    Lee, Hak Jong; Han, Joon Koo

    2001-01-01

    To evaluate the effects of threshold values, reconstruction interval, slice thickness and table speed on the spiral CT volumetry. Two phantoms made of a balloon and diluted contrast media underwent spiral CT scanning with section thicknesses of 5, 7 and 10 mm and table speeds of 5, 8 and 10 mm with scans of 5 mm section thickness, 7, 10, and 14 mm with scans of 7 mm section thickness, and 10, 15, and 20 mm with scans of 10 mm section thickness. The volumetric values of phantom A and B were obtained at varying threshold values and a reconstruction interval of 5 and 10 mm for all scans. Volumes were also determined with the threshold value fixed and a reconstruction interval of 1, 5, 7 and 10 mm, respectively. Three-dimensional display and volumetric measurements were obtained using reconstructed images. The effects of threshold value, reconstruction interval, slice thickness and table speed on volumetry were analyzed. Volumetric values varied according to threshold values. Where a threshold value was low, value increased as pitch increased, but where a the threshold value was high, value decreased as pitch increased. With varying threshold values, measurement errors in CT volumetry were 1.6 to 9.0%. Volume decreased as reconstruction interval increased. Where the table speed/ slice thickness ratio was constant, volume was constant though slice thickness differed. At fixed threshold values, variation in the reconstruction interval was statistically more significant than variation in slice thickness or table speed (p<0.05, Kruskal-Wallis one-way ANOVA). Among serveral spiral scanning and image reconstruction parameters including threshold value, reconstruction interval, slice thickness, and table speed, threshold value most affected the result obtained. At fixed threshold values, the reconstruction interval used had more effect on CT volumetry than other parameters

  10. The role of CT and MR in diagnosis of aortic dissection

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Lim, Tae Hwan; Song, Koun Sik; Min, Kyung Seok; Song, Meong Gun

    1994-01-01

    The purpose of this study was to determine the role of CT and MR imagings in the diagnosis of aortic dissection and differentiation between the true and false lumen. We retrospectively studied forty patients with aortic dissection(AD) diagnosed by imagings or surgery. Of the forty patients, 19 were examined with only CT, 14 with CT and MR, and 7 with MR. Our points of view were(1) the classification of AD according to configuration of intimal flap by cross-sectional imaging, (2) differentiation between the true and false lumens, (3) the course of the false lumen, and (4) detectability of the origin of major branch vessels of the abdominal aorta. The classification by cross-sectional imaging were crescentic(65%), circumferential(15%), flat(12%), and irregular(8%) type, in which false negative diagnosis was made in 1 case of crescentic and circumferential type, respectively. In 2 case of flat type and 1 case of irregular type, the differentiation between the true and false lumen was impossible with CT. The course of the false lumen in descending thoracic aorta revealed counterclock wise rotation(66%), clockwise rotation(5%) or fixed(29%) appearance. MR imaging was superior to CT in the detection of the origin of major branch vessels of the abdominal aorta. The determination of the origin of major branches of abdominal aorta arising from the true and false lumen were impossible in 2 cases in which only CT was done. Diagnosis of crescentic and circumferential types of AD with narrow and thrombosed false lumen was problematic in both CT and MR with no difference of diagnostic accuracy between the two modalities. The differentiation between the true and false lumen was difficult in flat and irregular types with only CT. Therefore, when surgical treatment is considered as in type B aortic dissection, MR imaging is recommended in order to determine the origin of major branch vessels

  11. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  12. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  13. FDG-PET, CT, MRI for diagnosis of local residual or recurrent nasopharyngeal carcinoma, which one is the best? A systematic review

    International Nuclear Information System (INIS)

    Liu Tao; Xu Wen; Yan Weili; Ye Ming; Bai Yongrui; Huang Gang

    2007-01-01

    Purpose: To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma. Materials and methods: MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard. Two reviewers independently extracted data. A software called 'Meta-DiSc' was used to obtain pooled estimates of sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the Q* index. Results: Twenty-one articles fulfilled all inclusion criteria. The pooled sensitivity estimates for PET (95%) were significantly higher than CT (76%) (P 0.05). Conclusion: FDG-PET was the best modality for diagnosis of local residual or recurrent nasopharyngeal carcinoma. The type of analysis for PET imaging and the section thickness for CT would affect the diagnostic results. Dual-section helical and multi-section helical CT were better than nonhelical and single-section helical CT

  14. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  15. Eisenmenger syndrome and idiopathic pulmonary arterial hypertension: do parenchymal lung changes reflect aetiology?

    International Nuclear Information System (INIS)

    Griffin, N.; Allen, D.; Wort, J.; Rubens, M.; Padley, S.

    2007-01-01

    Aim: To document the pulmonary vascular changes on thin-section computed tomography (CT) in patients with Eisenmenger syndrome and idiopathic pulmonary arterial hypertension, and to determine whether there is any correlation with pulmonary arterial pressures or the aetiology of pulmonary hypertension. Material and methods: From the National Pulmonary Hypertension Database, we identified eight patients with idiopathic pulmonary arterial hypertension and 20 patients with Eisenmenger syndrome (secondary to a ventriculoseptal defect) who had also undergone contrast-enhanced thin-section CT. CT studies were reviewed for the presence of centrilobular nodules, mosaicism, neovascularity, and bronchial artery hypertrophy. Haemodynamic data were also reviewed. Results: Centrilobular nodules, mosaicism, and neovascularity were seen in both patient groups (p > 0.05). A significantly higher number of enlarged bronchial arteries were seen in patients with Eisenmenger syndrome. There was no correlation with pulmonary arterial pressures. Conclusion: Patients with idiopathic pulmonary arterial hypertension and Eisenmenger syndrome demonstrated similar pulmonary vascular changes on CT. These changes did not predict the underlying cause of pulmonary hypertension or its severity

  16. Eisenmenger syndrome and idiopathic pulmonary arterial hypertension: do parenchymal lung changes reflect aetiology?

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, N. [Royal Brompton and Harefield NHS Trust, London (United Kingdom)]. E-mail: nyreegriffin@hotmail.com; Allen, D. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Wort, J. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Rubens, M. [Royal Brompton and Harefield NHS Trust, London (United Kingdom); Padley, S. [Royal Brompton and Harefield NHS Trust, London (United Kingdom)

    2007-06-15

    Aim: To document the pulmonary vascular changes on thin-section computed tomography (CT) in patients with Eisenmenger syndrome and idiopathic pulmonary arterial hypertension, and to determine whether there is any correlation with pulmonary arterial pressures or the aetiology of pulmonary hypertension. Material and methods: From the National Pulmonary Hypertension Database, we identified eight patients with idiopathic pulmonary arterial hypertension and 20 patients with Eisenmenger syndrome (secondary to a ventriculoseptal defect) who had also undergone contrast-enhanced thin-section CT. CT studies were reviewed for the presence of centrilobular nodules, mosaicism, neovascularity, and bronchial artery hypertrophy. Haemodynamic data were also reviewed. Results: Centrilobular nodules, mosaicism, and neovascularity were seen in both patient groups (p > 0.05). A significantly higher number of enlarged bronchial arteries were seen in patients with Eisenmenger syndrome. There was no correlation with pulmonary arterial pressures. Conclusion: Patients with idiopathic pulmonary arterial hypertension and Eisenmenger syndrome demonstrated similar pulmonary vascular changes on CT. These changes did not predict the underlying cause of pulmonary hypertension or its severity.

  17. CT- and MR-guided interventions in radiology. 2. ed.

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wilhelm, Kai E.; Ricke, Jens

    2013-01-01

    Revised and extended second edition that covers a broad range of non-vascular interventions guided by CT or MR imaging. Discusses in detail indications, materials, techniques, and results. Includes a comprehensive section on interventional oncology. Richly illustrated source of information and guidance for all radiologists who deal with non-vascular procedures. Interventional radiology is an indispensable and still expanding area of modern medicine that encompasses numerous diagnostic and therapeutic procedures. Cross-sectional imaging modalities such as computed tomography (CT) and magnetic resonance (MR) have emerged as important techniques for non-vascular interventions, including percutaneous biopsy, drainage, ablation, and neurolysis. Various organs, diseases, and lesions can be approached in this way, permitting the treatment and management of tumors, fluid collections, and pain, the embolization of endoleaks, the provision of access to hollow organs, etc. Accordingly, interventional radiology is now an integral component of the interdisciplinary management of numerous disorders. The revised and significantly extended second edition of this volume covers a broad range of non-vascular interventions guided by CT or MR imaging. Indications, materials, techniques, and results are all carefully discussed. A particularly comprehensive section is devoted to interventional oncology as the most rapidly growing branch of interventional radiology. In addition, detailed information is provided that will assist in establishing and developing an interventional service. This richly illustrated book will be a most valuable source of information and guidance for all radiologists who deal with non-vascular procedures.

  18. Quantitation of repaglinide and metabolites in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Chen, Weiqi; Wang, Lifei; Van Berkel, Gary J; Kertesz, Vilmos; Gan, Jinping

    2016-03-25

    Herein, quantitation aspects of a fully automated autosampler/HPLC-MS/MS system applied for unattended droplet-based surface sampling of repaglinide dosed thin tissue sections with subsequent HPLC separation and mass spectrometric analysis of parent drug and various drug metabolites were studied. Major organs (brain, lung, liver, kidney and muscle) from whole-body thin tissue sections and corresponding organ homogenates prepared from repaglinide dosed mice were sampled by surface sampling and by bulk extraction, respectively, and analyzed by HPLC-MS/MS. A semi-quantitative agreement between data obtained by surface sampling and that by employing organ homogenate extraction was observed. Drug concentrations obtained by the two methods followed the same patterns for post-dose time points (0.25, 0.5, 1 and 2 h). Drug amounts determined in the specific tissues was typically higher when analyzing extracts from the organ homogenates. In addition, relative comparison of the levels of individual metabolites between the two analytical methods also revealed good semi-quantitative agreement. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  20. Usefulness of bone window CT images parallel to the transnasal surgical route for pituitary disorders

    International Nuclear Information System (INIS)

    Abe, T.; Kunii, N.; Ikeda, H.; Izumiyama, H.; Asahina, N.

    2003-01-01

    Before operating on 130 patients with pituitary disorders, we evaluated their bone window CT images sliced parallel to the trans nasal surgical route to assess the surgical anatomy of the nasal cavity for trans nasal surgery. High resolution bone window CT was performed in 3- to 5-mm slices parallel to the imaginary line connecting the inferior margin of the piriform aperture and the top of the sellar floor, parallel to the trans nasal surgical route. This CT angle was useful in evaluating the width and depth of the operative hold, the bony components of the nasal conchas, deviation of the nasal septum, the bony structure and mucosa in the sphenoid sinus, and the condition of the sellar floor. In patients requiring repeat surgery, the location of thin or thick nasal mucosa, residual bony septum, and inadequate sellar floor opening were easily detected. Bone window CT images sliced parallel to the trans nasal surgical route provide direct visualization of the nasal anatomy for the trans nasal approach. This method is helpful in determining how far to remove the sellar floor laterally, especially in cases requiring repeat surgery. (author)