WorldWideScience

Sample records for thermal equipment users

  1. The point of view of thermal equipment users; Le point de vue des gestionnaires d`equipements thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Barroyer, P. [Compagnie Generale de Chauffe, 59 - Saint Andre Lez Lille (France)

    1997-12-31

    The influence of new pollution regulations in France on the operation of thermal equipment for central heating systems or industrial heat process systems, is examined. The main French regulations concerning air pollution control and energy rational consumption are reviewed, and their effects on the design, equipment, operation and costs of heat plants are discussed: impacts of the decree on upgrading and disposal of fossil fuel ashes, the decree on special protection zone (large cities), the clean air law, the compulsory declaration for classified combustion plants and limit air pollution emission levels

  2. ISS qualified thermal carrier equipment

    Science.gov (United States)

    Deuser, Mark S.; Vellinger, John C.; Jennings, Wm. M.

    2000-01-01

    Biotechnology is undergoing a period of rapid and sustained growth, a trend which is expected to continue as the general population ages and as new medical treatments and products are conceived. As pharmaceutical and biomedical companies continue to search for improved methods of production and, for answers to basic research questions, they will seek out new avenues of research. Space processing on the International Space Station (ISS) offers such an opportunity! Space is rapidly becoming an industrial laboratory for biotechnology research and processing. Space bioprocessing offers exciting possibilities for developing new pharmaceuticals and medical treatments, which can be used to benefit mankind on Earth. It also represents a new economic frontier for the private sector. For over eight years, the thermal carrier development team at SHOT has been working with government and commercial sector scientists who are conducting microgravity experiments that require thermal control. SHOT realized several years ago that the hardware currently being used for microgravity thermal control was becoming obsolete. It is likely that the government, academic, and industrial bioscience community members could utilize SHOT's hardware as a replacement to their current microgravity thermal carrier equipment. Moreover, SHOT is aware of several international scientists interested in utilizing our space qualified thermal carrier. SHOT's economic financing concept could be extremely beneficial to the international participant, while providing a source of geographic return for their particular region. Beginning in 2000, flight qualified thermal carriers are expected to be available to both the private and government sectors. .

  3. Equipment for dekryptonation thermal analysis

    International Nuclear Information System (INIS)

    Lukac, P.; Pruzinec, J.

    Emanation thermal analysis is used for studying changes in the dynamic temperature conditions during kinetics studies of some reactions in solids. A kryptonated sample is placed in a furnace with a programmable temperature controller. 85 Kr released from the sample is entrapped by the carrier gas in a through-flow Geiger-Mueller detector. The detector signal is processed into an integral form and recorded. Examples are given of the study of modification transformations in NH 4 NO 3 , pearlite and PVC. (M.D.)

  4. User's manual for the master equipment list. Phase 1

    International Nuclear Information System (INIS)

    Sandoval, J.D.

    1997-01-01

    This manual is intended to provide a user with enough detailed instruction to guide them through the Master Equipment List Phase 1 (MEL Phase 1) application system operations. The MEL Phase 1 application is a database system that stores Equipment Identification Number (EIN) information to support equipment tracking in the 200E and 200W Tank Farms for the Tank Waste Remediation System Division. The MEL Phase 1 application supports both the user application and administrative control functions. The user application functions include: viewing by Folder, reporting, performing queries, and editing specific data. The administrative control functions include: maintaining valid user identifications, passwords, privileges, defining drop-down lists, and review of the change log relating to EIN data entries, additions, deletions, and editing. The scope of this User's Manual is to discuss these functions and is intended to guide users and answer questions regarding the MEL Phase 1 application

  5. Equipment Qualification Data Base user manual

    International Nuclear Information System (INIS)

    Decker, Q.R.; Fackrell, L.J.; Fitch, L.R.; Meeky, O.B.

    1985-09-01

    This manual details the Equipment Qualification Data Base (EQDB), its usage, and contents. The EQDB consists of two files; the Plant Qualification File (PQF) and the Equipment Qualification File (EQF). The PQF contains plant specific environmental data and the EQF contains summaries of various test results. Two data management systems are used to manipulate the data and are discussed in this manual. SAS Institute System 2000 (S2K) is the management system for the PQF and Query Update (QU) is the operating system for the EQF. Each management system contains report writers. These writers and how to use them are discussed in detail in this manual

  6. CASDAC system: Data Terminal Equipment user's guide

    International Nuclear Information System (INIS)

    Yamamoto, Yoichi; Koyama, Kinji

    1993-03-01

    The CASDAC (Containment And Surveillance Data Authenticated Communication) system has been developed by JAERI for nuclear safeguards and physical protection of nuclear material. This system is a remote monitoring system for continual verification of security and safeguards status of nuclear material. The CASDAC system consists of two subsystems, one of them is a Grand Command Center (GCC) subsystem and the other is a facility subsystem. This report describes the outline and usage of the Data Terminal Equipment (DTE), which makes available of message data communication between the GCC and a facility subsystem. This work has been carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JA-1. (author)

  7. A generalized development model for testing GPS user equipment

    Science.gov (United States)

    Hemesath, N.

    1978-01-01

    The generalized development model (GDM) program, which was intended to establish how well GPS user equipment can perform under a combination of jamming and dynamics, is described. The systems design and the characteristics of the GDM are discussed. The performance aspects of the GDM are listed and the application of the GDM to civil aviation is examined.

  8. Power-Consumption Measurements for LTE User Equipment

    DEFF Research Database (Denmark)

    Lauridsen, Mads

    wireless communications test set and the Agilent N6705B DC power analyzer to establish a power consumption model for LTE user equipment (UE). The model is useful when you need to examine the UE battery life in system-level simulations. We will explain how the Agilent equipment can be used in manual tests......, but we do not discuss how to make automated tests (for example, using VEE software). In this application note, we analyze smartphones adhering to the 3GPP LTE standard [1]....

  9. Problems associated with accelerated thermal aging of electrical equipment

    International Nuclear Information System (INIS)

    Isgro, J.R.

    1984-01-01

    This paper discusses the potential problems that may be experienced when accounting for aging mechanisms in organic polymers when utilizing accelerated thermal aging techniques for electrical equipment qualification. Included are discussions of actual experiences and problems encountered in the qualification of electrical and electronic equipment for a complete nuclear power plant. The wide variety of approaches to thermal accelerated aging by various manufacturers of diverse equipment types provides depth to the discussion. A description of how to account for aging mechanisms is also presented

  10. Verification of the thermal design of electronic equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hienonen, R.; Karjalainen, M.; Lankinen, R. [VTT Automation, Espoo (Finland). ProTechno

    1997-12-31

    The project `Verification of the thermal design of electronic equipment` studied the methodology to be followed in the verification of thermal design of electronic equipment. This project forms part of the `Cool Electronics` research programme funded by TEKES, the Finnish Technology Development Centre. This project was carried out jointly by VTT Automation, Lappeenranta University of Technology, Nokia Research Center and ABB Industry Oy VSD-Technology. The thermal design of electronic equipment has a significant impact on the cost, reliability, tolerance to different environments, selection of components and materials, and ergonomics of the product. This report describes the method for verification of thermal design. It assesses the goals set for thermal design, environmental requirements, technical implementation of the design, thermal simulation and modelling, and design qualification testing and the measurements needed. The verification method covers all packaging levels of electronic equipment from the system level to the electronic component level. The method described in this report can be used as part of the quality system of a corporation. The report includes information about the measurement and test methods needed in the verification process. Some measurement methods for the temperature, flow and pressure of air are described. (orig.) Published in Finnish VTT Julkaisuja 824. 22 refs.

  11. Innovation on methodology, thermal modelling and materials for personal equipment

    NARCIS (Netherlands)

    Oudenhuijzen, A.J.K.; Reulink, H.G.B.; Kistemaker J.A.

    2012-01-01

    Everybody seems to know how simple it is to procure personal equipment (PE). Still, users of PE are too often confronted with shortcomings in their PE: they may be hampered, or and/or individual components of the PE ensemble do not work together. So the question is: do we really know how to procure

  12. Solar thermal electric power information user study

    Energy Technology Data Exchange (ETDEWEB)

    Belew, W.W.; Wood, B.L.; Marle, T.L.; Reinhardt, C.L.

    1981-02-01

    The results of a series of telephone interviews with groups of users of information on solar thermal electric power are described. These results, part of a larger study on many different solar technologies, identify types of information each group needed and the best ways to get information to each group. The report is 1 of 10 discussing study results. The overall study provides baseline data about information needs in the solar community. An earlier study identified the information user groups in the solar community and the priority (to accelerate solar energy commercialization) of getting information to each group. In the current study only high-priority groups were examined. Results from five solar thermal electric power groups of respondents are analyzed: DOE-Funded Researchers, Non-DOE-Funded Researchers, Representatives of Utilities, Electric Power Engineers, and Educators. The data will be used as input to the determination of information products and services the Solar Energy Research Institute, the Solar Energy Information Data Bank Network, and the entire information outreach community should be preparing and disseminating.

  13. Energy demand and thermal comfort of HVAC systems with thermally activated building systems as a function of user profile

    Science.gov (United States)

    Pałaszyńska, Katarzyna; Bandurski, Karol; Porowski, Mieczysław

    2017-11-01

    Thermally Activated Building Systems (TABS) are a way to use building structure as a thermal energy storage. As a result, renewable energy sources may be used more efficiently. The paper presents numerical analysis of a HVAC system with TABS energy demand and indoor thermal comfort of a representative room in a non-residential building (governmental, commercial, educational). The purpose of analysis is to investigate the influence of a user profile on system performance. The time span of the analysis is one year - a typical meteorological year. The model was prepared using a generally accepted simulation tool - TRNSYS 17. The results help to better understand the interaction of a user profile with TABS. Therefore they are important for the development of optimal control algorithms for energy efficient buildings equipped with such systems.

  14. Energy demand and thermal comfort of HVAC systems with thermally activated building systems as a function of user profile

    Directory of Open Access Journals (Sweden)

    Pałaszyńska Katarzyna

    2017-01-01

    Full Text Available Thermally Activated Building Systems (TABS are a way to use building structure as a thermal energy storage. As a result, renewable energy sources may be used more efficiently. The paper presents numerical analysis of a HVAC system with TABS energy demand and indoor thermal comfort of a representative room in a non-residential building (governmental, commercial, educational. The purpose of analysis is to investigate the influence of a user profile on system performance. The time span of the analysis is one year – a typical meteorological year. The model was prepared using a generally accepted simulation tool – TRNSYS 17. The results help to better understand the interaction of a user profile with TABS. Therefore they are important for the development of optimal control algorithms for energy efficient buildings equipped with such systems.

  15. Thermal analysis of the failed equipment storage vault system

    International Nuclear Information System (INIS)

    Jerrell, J.; Lee, S.Y.; Shadday, A.

    1995-07-01

    A storage facility for failed glass melters is required for radioactive operation of the Defense Waste Processing Facility (DWPF). It is currently proposed that the failed melters be stored in the Failed Equipment Storage Vaults (FESV's) in S area. The FESV's are underground reinforced concrete structures constructed in pairs, with adjacent vaults sharing a common wall. A failed melter is to be placed in a steel Melter Storage Box (MSB), sealed, and lowered into the vault. A concrete lid is then placed over the top of the FESV. Two melters will be placed within the FESV/MSB system, separated by the common wall. There is no forced ventilation within the vault so that the melter is passively cooled. Temperature profiles in the Failed Equipment Storage Vault Structures have been generated using the FLOW3D software to model heat conduction and convection within the FESV/MSB system. Due to complexities in modeling radiation with FLOW3D, P/THERMAL software has been used to model radiation using the conduction/convection temperature results from FLOW3D. The final conjugate model includes heat transfer by conduction, convection, and radiation to predict steady-state temperatures. Also, the FLOW3D software has been validated as required by the technical task request

  16. Apparatus for determining the thermal history of equipment using solid state track recorders

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Lippincott, E.P.; Fero, A.H.; Schreiber, R.B.; Seidel, J.G.

    1991-01-01

    This patent describes a nuclear power plant having equipment subject to thermal aging, the rate of the thermal aging being capable of characterization by at least one equipment Arrhenius function of temperature, the equipment being subjected to a temperature environment having a predetermined range of temperatures, apparatus for determining the thermal aging which has occurred in the equipment. It comprises passive sensors, each of the sensors being formed from a selected material and subject to a thermal aging process within the range of temperatures, the extent of the thermal aging in each respective sensor being quantifiable, the rate at which the thermal aging process progresses in each of the sensors being characterized by a respective Arrhenius function of temperature; and the selected material not being the same for each of the sensors, whereby the range of activation energy values characterizing the respective Arrhenius functions encompasses the activation energy value characterizing the equipment Arrhenius function

  17. Constructing a User Interface for Cellular Phones Using Equipment and its Relations

    Directory of Open Access Journals (Sweden)

    Misayo Kitamura

    2003-04-01

    Full Text Available In a domain of SCADA (Supervisory Control And Data Acquisition systems, it is necessary to obtain information about plants such as water plants in remote places using a cellular phone in order to ascertain plant status in case of emergency.T o utilize the small screen of a cellular phone and to eliminate the engineering cost of creating de.nition data to show plant status, a method of constructing user interface using equipment in the plant and its relations is proposed. In this method, some equipment is selected from all supervised equipment using the relations between the equipment, and then the content to be displayed is generated dynamically using the selected equipment. The equipment in plants is organized as a graph structure, which involves the equipment and the relations between the equipment.T he relations adopted in this method are both the physical connections between the equipment and the conceptual relationships.The result of the selection depends on the relations and their parameter values called the context dependent weight, which changes dynamically by viewpoints.

  18. Flexible thermal cycle test equipment for concentrator solar cells

    Science.gov (United States)

    Hebert, Peter H [Glendale, CA; Brandt, Randolph J [Palmdale, CA

    2012-06-19

    A system and method for performing thermal stress testing of photovoltaic solar cells is presented. The system and method allows rapid testing of photovoltaic solar cells under controllable thermal conditions. The system and method presents a means of rapidly applying thermal stresses to one or more photovoltaic solar cells in a consistent and repeatable manner.

  19. Exploring How Peer Communities Enable Lead User Innovations to Become Standard Equipment in the Industry

    DEFF Research Database (Denmark)

    Hienerth, Christoph; Lettl, Christopher

    2011-01-01

    Literature on new product development indicates that on average around 40% of new products fail across different industries (e.g., Crawford, ; Crawford and Di Benedetto, ). Out of those that survive only few become widely accepted standard equipment in the industry (Utterback, ). Literature...... they are developed. It is therefore the aim of this study to shed light on how innovations become widely accepted by large segments of the market and specifically which demand-side forces are at work. An approach suitable for pursuing this objective is to focus on those individuals who are on the leading edge...... with respect to an important market trend (lead users) and their respective peer communities. As little knowledge is available, an explorative case study design is applied, working with cases from two different industries, specifically the medical equipment and sporting equipment industry. A longitudinal...

  20. The point of view from thermal equipment managers; Le point de vue des gestionnaires d`equipements thermiques

    Energy Technology Data Exchange (ETDEWEB)

    Barroyeur, P. [Compagnie General de Chauffe, 59 - Saint Andre Lez Lille (France)

    1997-12-31

    The new French regulations on air pollution and classified installations have increased the technical and economical constraints of thermal equipment managers in the domain of collective space heating and industrial heating. The aim of this paper is to precise the impact of these regulations in particular, on the valorization and elimination of fossil fuel ashes, and on the design, operation and maintenance of combustion installations (maximum acceptable limits of pollutant emissions). (J.S.)

  1. Equipment for thermal neutron flux measurements in reactor R2

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E; Nilsson, T; Claeson, S

    1960-04-15

    For most of the thermal neutron flux measurements in reactor R2 cobalt wires will be used. The loading and removal of these wires from the reactor core will be performed by means of a long aluminium tube and electromagnets. After irradiation the wires will be scanned in a semi-automatic device.

  2. Development of instrumentation in the transport phenomena research in thermal equipment

    International Nuclear Information System (INIS)

    Carvalho Tofani, P. de; Ladeira, L.C.D.

    1983-11-01

    The results obtained from the effort on the acquisition of know-how in experimental reactor thermal during the last years, through the approach of relevant aspects of basic research on transport phenomena applicable to nuclear reactor analysis and conventional thermal equipment based in the simultaneous development of instrumentation and experimental methods are presented. (E.G.) [pt

  3. Equipping simulators with an advanced thermal hydraulics model EDF's experience

    International Nuclear Information System (INIS)

    Soldermann, R.; Poizat, F.; Sekri, A.; Faydide, B.; Dumas, J.M.

    1997-01-01

    The development of an accelerated version of the advanced CATHARe-1 thermal hydraulics code designed for EDF training simulators (CATHARE-SIMU) was successfully completed as early as 1991. Its successful integration as the principal model of the SIPA Post-Accident Simulator meant that its use could be extended to full-scale simulators as part of the renovation of the stock of existing simulators. In order to further extend the field of application to accidents occurring in shutdown states requiring action and to catch up with developments in respect of the CATHARE code, EDF initiated the SCAR Project designed to adapt CATHARE-2 to simulator requirements (acceleration, parallelization of the computation and extension of the simulation range). In other respects, the installation of SIPA on workstations means that the authors can envisage the application of this remarkable training facility to the understanding of thermal hydraulics accident phenomena

  4. Ensuring Energy Efficient 5G User Equipment by Technology Evolution and Reuse

    DEFF Research Database (Denmark)

    Lauridsen, Mads; Berardinelli, Gilberto; Sørensen, Troels Bundgaard

    2014-01-01

    the features’ pros and cons in achieving high performance in terms of data rate and/or latency while limiting their effect on the UE power consumption. Based on the discussion we give general recommendations for an energy efficient 5G design in the context of a previously proposed RAT concept.......Research on fifth generation (5G) radio access technology (RAT) is ramping up, with the goal of significantly improving user data rates and latency compared to previous radio generations. While energy efficiency (EE) of the user equipment (UE) was not a key optimization parameter for the current...... standards, it is anticipated to become a distinguishing factor for 5G. In this paper, we analyze established and emerging technological solutions for features such as waveform, frame structure, duplexing and multiple antenna transmission from an EE perspective. Our contribution is to identify and discuss...

  5. Iterative Relay Scheduling with Hybrid ARQ under Multiple User Equipment (Type II) Relay Environments

    KAUST Repository

    Nam, Sung Sik

    2018-01-09

    In this work, we propose an iterative relay scheduling with hybrid ARQ (IRS-HARQ) scheme which realizes fast jump-in/successive relaying and subframe-based decoding under the multiple user equipment (UE) relay environments applicable to the next-generation cellular systems (e.g., LTE-Advanced and beyond). The proposed IRS-HARQ aims to increase the achievable data rate by iteratively scheduling a relatively better UE relay closer to the end user in a probabilistic sense, provided that the relay-to-end user link should be operated in an open-loop and transparent mode. The latter is due to the fact that not only there are no dedicated control channels between the UE relay and the end user but also a new cell is not created. Under this open-loop and transparent mode, our proposed protocol is implemented by partially exploiting the channel state information based on the overhearing mechanism of ACK/NACK for HARQ. Further, the iterative scheduling enables UE-to-UE direct communication with proximity that offers spatial frequency reuse and energy saving.

  6. Influence of user behavior on unsatisfactory indoor thermal environment

    International Nuclear Information System (INIS)

    Yan, Biao; Long, Enshen; Meng, Xi; Zhang, Yuanze; Hou, Dongqi; Du, Xin

    2014-01-01

    Highlights: • The methodology of numerical simulation of 3D heat-flux visualization is proposed. • A full-scale model of prototype office for each influential factor was set up. • The simulation results were compared with the indoor occupant comfort levels. • The contrast of average temperature increase due to user behavior was presented. - Abstract: In areas of China that have hot summers and cold winters, the overall performance of HVAC systems in the poorly-insulated existing office buildings is generally not satisfactory, especially in extreme weather conditions. The reasons for the unsatisfactory indoor thermal environment were deduced, and to validate the findings, a methodology of numerical simulation for 3D heat-flux visualization was proposed. A full-scale model of a prototype office room was created, with representative working conditions for the characteristics of particular building. The results of the heat-flux visualization and temperature distribution showed that the overall effect was resulted from merged reasons, and that significance ranking of each reason varied when the outside environmental conditions changed. The simulation results were compared with the indoor occupant comfort levels of the volunteers who worked in the target room. Models of possible influential factors such as the outdoor temperature, opening or closing windows, and the effect of window shading devices (WSD) were set up. The influence of user behavior on indoor temperature in opening window, or not using WSD was proven to be significant in causing unfavorable indoor conditions. According to the visualized evaluation and analysis of the various factors, corresponding methods for both improving indoor thermal conditions and saving energy are proposed

  7. Thermal fatigue equipment to test joints of materials for high heat flux components

    International Nuclear Information System (INIS)

    Visca, E.; Libera, S.; Orsini, A.; Riccardi, B.; Sacchetti, M.

    2000-01-01

    The activity, carried out in the framework of an ITER divertor task, was aimed at defining a suitable method in order to qualify junctions between armour materials and heat sink of plasma-facing components (PFCs) mock-ups. An equipment able to perform thermal fatigue testing by electrical heating and active water-cooling was constructed and a standard for the sample was defined. In this equipment, during operation cycles, two samples are heated by thermal contact up to a relevant temperature value (350 deg. C) and then the water flow is switched on, thus producing fast cooling with time constants and gradients close to the real operating conditions. The equipment works with a test cycle of about 60 s and is suitable for continuous operation. A complete test consists of about 10000 cycles. After the assembling, the equipment and the control software were optimized to obtain a good reliability. Preliminary tests on mock-ups with flat CFC tiles joined to copper heat sink were performed. Finite-elements calculations were carried out in order to estimate the value of the thermal stresses arising close to the joint under the transient conditions that are characteristic of this equipment

  8. Improving the efficiency of thermal power equipment based on technologies using surfactants

    Science.gov (United States)

    Nikolaeva, L. A.; Zueva, O. S.

    2015-10-01

    The formation of deposits on the functional surfaces of the equipment of heating systems and their corrosion are one of the major energetic problems. To improve the operational efficiency of thermal power equipment, surface-active agents (surfactants) are widely used, which are applied for the treatment of the working surfaces before use, during use, to prevent the parking corrosion, as well as while performing periodic chemical cleanings of power equipment. The tests have been performed, and the technology of application of Auge Neo Ac 56 acid product (MAHIM, Kazan) has been developed, designed to remove mineral deposits and scale from cooling and boiler systems without mechanical influence on them and without disassembly of technological equipment.

  9. Improving the Thermal Testing Technology of Technological Equipment of Autonomous Complexes

    Directory of Open Access Journals (Sweden)

    V. V. Chugunkov

    2017-01-01

    Full Text Available The environmental conditions of autonomous objects of different-purpose technical complexes are in close relationship with increased values of operating temperatures. This requires thermal pretesting of the process equipment. The publication [1] considers the thermal test conditions in which the equipment elements under test are placed in a heated water tank covered by the globe insulators where, under automatic temperature control using a block of heaters, they are then kept for a specified period of time at a specified temperature range. Such an approach to the thermal tests of equipment allows us to reduce, but not eliminate completely the mass flows of water from evaporation with reducing power consumption of test equipment.Despite the results achieved, even a little bit of water vapor available when conducting the thermal tests may cause a failure of equipment. Therefore, there is a need in test equipment modernization for complete eliminating the fluxes of mass water and better power consumption in the test process. To this end, it is proposed to place a three-layer bubble wrap on the open surface of water.To justify an efficiency of the proposed option was developed a mathematical model of heat and mass transfer processes that occur during thermal tests, taking into account the geometric and thermo-physical characteristics of test tank, polymer film, and equipment. Using the laws and equations of heat and mass transfer enabled us to determine the required capacities for heating the tank with water and equipment to the required temperature range for a specified time, as well as the mass flows of water when evaporating from the tank surface.The efficiency of the three-layer bubble film as compared with the globe insulators as the elements for covering the test tank the surface has been analysed on the basis of the results obtained.The proposed film coating allowed almost complete elimination of evaporation losses of water mass and almost 8

  10. Joint energy demand and thermal comfort optimization in photovoltaic-equipped interconnected microgrids

    International Nuclear Information System (INIS)

    Baldi, Simone; Karagevrekis, Athanasios; Michailidis, Iakovos T.; Kosmatopoulos, Elias B.

    2015-01-01

    Highlights: • Energy efficient operation of photovoltaic-equipped interconnected microgrids. • Optimized energy demand for a block of heterogeneous buildings with different sizes. • Multiobjective optimization: matching demand and supply taking into account thermal comfort. • Intelligent control mechanism for heating, ventilating, and air conditioning units. • Optimization of energy consumption and thermal comfort at the aggregate microgrid level. - Abstract: Electrical smart microgrids equipped with small-scale renewable-energy generation systems are emerging progressively as an alternative or an enhancement to the central electrical grid: due to the intermittent nature of the renewable energy sources, appropriate algorithms are required to integrate these two typologies of grids and, in particular, to perform efficiently dynamic energy demand and distributed generation management, while guaranteeing satisfactory thermal comfort for the occupants. This paper presents a novel control algorithm for joint energy demand and thermal comfort optimization in photovoltaic-equipped interconnected microgrids. Energy demand shaping is achieved via an intelligent control mechanism for heating, ventilating, and air conditioning units. The intelligent control mechanism takes into account the available solar energy, the building dynamics and the thermal comfort of the buildings’ occupants. The control design is accomplished in a simulation-based fashion using an energy simulation model, developed in EnergyPlus, of an interconnected microgrid. Rather than focusing only on how each building behaves individually, the optimization algorithm employs a central controller that allows interaction among the buildings of the microgrid. The control objective is to optimize the aggregate microgrid performance. Simulation results demonstrate that the optimization algorithm efficiently integrates the microgrid with the photovoltaic system that provides free electric energy: in

  11. Preliminary Study of UAS Equipped with Thermal Camera for Volcanic Geothermal Monitoring in Taiwan.

    Science.gov (United States)

    Chio, Shih-Hong; Lin, Cheng-Horng

    2017-07-18

    Thermal infrared cameras sense the temperature information of sensed scenes. With the development of UASs (Unmanned Aircraft Systems), thermal infrared cameras can now be carried on a quadcopter UAV (Unmanned Aircraft Vehicle) to appropriately collect high-resolution thermal images for volcanic geothermal monitoring in a local area. Therefore, the quadcopter UAS used to acquire thermal images for volcanic geothermal monitoring has been developed in Taiwan as part of this study to overcome the difficult terrain with highly variable topography and extreme environmental conditions. An XM6 thermal infrared camera was employed in this thermal image collection system. The Trimble BD970 GNSS (Global Navigation Satellite System) OEM (Original Equipment Manufacturer) board was also carried on the quadcopter UAV to gather dual-frequency GNSS observations in order to determine the flying trajectory data by using the Post-Processed Kinematic (PPK) technique; this will be used to establish the position and orientation of collected thermal images with less ground control points (GCPs). The digital surface model (DSM) and thermal orthoimages were then produced from collected thermal images. Tests conducted in the Hsiaoyukeng area of Taiwan's Yangmingshan National Park show that the difference between produced DSM and airborne LIDAR (Light Detection and Ranging) data are about 37% between -1 m and 1 m, and 66% between -2 m and 2 m in the area surrounded by GCPs. As the accuracy of thermal orthoimages is about 1.78 m, it is deemed sufficient for volcanic geothermal monitoring. In addition, the thermal orthoimages show some phenomena not only more globally than do the traditional methods for volcanic geothermal monitoring, but they also show that the developed system can be further employed in Taiwan in the future.

  12. Preliminary Study of UAS Equipped with Thermal Camera for Volcanic Geothermal Monitoring in Taiwan

    Directory of Open Access Journals (Sweden)

    Shih-Hong Chio

    2017-07-01

    Full Text Available Thermal infrared cameras sense the temperature information of sensed scenes. With the development of UASs (Unmanned Aircraft Systems, thermal infrared cameras can now be carried on a quadcopter UAV (Unmanned Aircraft Vehicle to appropriately collect high-resolution thermal images for volcanic geothermal monitoring in a local area. Therefore, the quadcopter UAS used to acquire thermal images for volcanic geothermal monitoring has been developed in Taiwan as part of this study to overcome the difficult terrain with highly variable topography and extreme environmental conditions. An XM6 thermal infrared camera was employed in this thermal image collection system. The Trimble BD970 GNSS (Global Navigation Satellite System OEM (Original Equipment Manufacturer board was also carried on the quadcopter UAV to gather dual-frequency GNSS observations in order to determine the flying trajectory data by using the Post-Processed Kinematic (PPK technique; this will be used to establish the position and orientation of collected thermal images with less ground control points (GCPs. The digital surface model (DSM and thermal orthoimages were then produced from collected thermal images. Tests conducted in the Hsiaoyukeng area of Taiwan’s Yangmingshan National Park show that the difference between produced DSM and airborne LIDAR (Light Detection and Ranging data are about 37% between −1 m and 1 m, and 66% between −2 m and 2 m in the area surrounded by GCPs. As the accuracy of thermal orthoimages is about 1.78 m, it is deemed sufficient for volcanic geothermal monitoring. In addition, the thermal orthoimages show some phenomena not only more globally than do the traditional methods for volcanic geothermal monitoring, but they also show that the developed system can be further employed in Taiwan in the future.

  13. DEVELOPMENT OF PROTOTYPE SYSTEM FOR REGULATING THERMAL CONDITIONS OF TELECOMMUNICATIONS EQUIPMENT CABINETS

    Directory of Open Access Journals (Sweden)

    A. T. Rashidkhanov

    2017-01-01

    Full Text Available Objectives. The main objective of the study was to regulate the thermal regime and ensure the reliability of electronic equipmentMethods. In order to conduct experimental studies of the thermoelectric cooling system using heat pipes, a stand was assembled on which the developed and manufactured prototype was studied. The object of the experimental studies was a prototype cooling system, consisting of a thermoelectric battery made of conventional unified thermoelectric materials of ICE-71 type. The solution of the research problems carried out by the method of reduction to ordinary differential equations (Kantorovich method provides acceptable accuracy for such a class of problems.Results. A design of a telecommunication equipment cabinet with a thermal management system based on the use of heat pipes and thermoelectric cooling units is proposed. A mathematical model for the determination of the thermal field in the cabinet volume is considered; an experimental stand for the prototype study is described; the results of experimental studies for various power sources of heat release are presented.Conclusion. Experimental studies confirm the operability of the developed cooling system for cabinets with telecommunication equipment; this cooling method has advantages over conventional forced or natural cooling; the temperature in the block volume and the peak values of the heat sources are significantly reduced; at dissipation powers on one board within 50 W there is no need to use special means to remove heat from hot junctions of the thermoelectric battery.

  14. Predictors of sharing injection equipment by HIV-seropositive injection drug users.

    Science.gov (United States)

    Latkin, Carl A; Buchanan, Amy S; Metsch, Lisa R; Knight, Kelly; Latka, Mary H; Mizuno, Yuko; Knowlton, Amy R

    2008-12-01

    Among HIV-positive injection drug users (IDUs), we examined baseline predictors of lending needles and syringes and sharing cookers, cotton, and rinse water in the prior 3 months at follow-up. Participants were enrolled in Intervention for Seropositive Injectors-Research and Evaluation, a secondary prevention intervention for sexually active HIV-positive IDUs in 4 US cities during 2001-2005. The analyses involved 357 participants who reported injecting drugs in the prior 6 months at either the 6- or 12-month follow-up visit. About half (49%) reported at least 1 sharing episode. In adjusted analyses, peer norms supporting safer injection practices and having primary HIV medical care visits in the prior 6 months were associated with reporting no sharing of injection equipment. Higher levels of psychological distress were associated with a greater likelihood of reporting drug paraphernalia sharing. These findings suggest that intervention approaches for reducing HIV-seropositive IDUs' transmission of blood-borne infections should include peer-focused interventions to alter norms of drug paraphernalia sharing and promoting primary HIV care and mental health services.

  15. Design, manufacture and installation of measuring and control equipments for the advanced thermal prototype reactor 'Fugen'

    International Nuclear Information System (INIS)

    Hirota, Shigeo; Kawabata, Yoshinori

    1979-01-01

    The advanced thermal prototype reactor ''Fugen'' attained the criticality on March 20, 1978, and 100% output operation on November 13, 1978. On March 20, 1979, it passed the final inspection, and since then, it has continued the smooth operation up to now. The measuring and control equipments are provided for grasping the operational conditions of the plant and operating it safely and efficiently. At the time of designing, manufacturing and installing the measuring and control equipments for Fugen, it was required to clarify the requirements of the plant design, to secure the sufficient functions, and to improve the operational process, maintainability and the reliability and accuracy of the equipments. Many design guidelines and criteria were decided in order to coordinate the conditions among five manufacturers and give the unified state as one plant. The outline of the instrumentations for neutrons, radiation monitoring and process data, the control systems for reactivity, reactor output, pressure and water supply, the safety protection system, and the process computer are described. Finally, the installations and tests of the measuring and control equipments are explained. The aseismatic capability of the equipments was confirmed. (Kako, I.)

  16. Analysis of Technical State of Thermal and Mechanical Equipment of Thermal Power Stations in the Republic of Belarus under Conditions of Investment Deficit

    Directory of Open Access Journals (Sweden)

    S. N. Shichko

    2004-01-01

    Full Text Available The paper contains an analysis of the equipment state at a number of thermal power stations. This analysis is made on the basis of indifferent curves. Relationship of two factors is taken as a criterion for estimation of the equipment state. These factors are faultiness (parameter of failure fi"equency and operating time from the moment when the equipment was put into operation. It is noted that operation of the equipment in excess of specified life without replacement of so-called «weab> elements and estimation of metal state will lead to conditions of high risk in opieration of such equipment.

  17. EQUIP training the trainers: an evaluation of a training programme for service users and carers involved in training mental health professionals in user-involved care planning.

    Science.gov (United States)

    Fraser, C; Grundy, A; Meade, O; Callaghan, P; Lovell, K

    2017-08-01

    WHAT IS KNOWN ON THE SUBJECT?: UK NHS policy highlights the importance of user and carer involvement in health professional training. We know little about service user and carer motivations and experiences of accessing training courses for delivering training to health professionals and how well such courses prepare them for delivering training to healthcare professionals. 'Involvement' in training has often been tokenistic and too narrowly focused on preregistration courses. There is limited data on how best to prepare and support potential service user and carer trainers. WHAT DOES THIS PAPER ADD TO EXISTING KNOWLEDGE?: This study adds to the international literature by highlighting service user and carer motivations for accessing a training course for delivering training to health professionals. Service users and carers wanted to gain new skills and confidence in presentation/facilitation as well as to make a difference to healthcare practice. We also learned that service users desired different levels of involvement in training facilitation - some wanted to take a more active role than others. A one-size-fits-all approach is not always appropriate. Encountering resistance from staff in training was a previously unidentified challenge to service user and carers' experience of delivering training in practice and is a key challenge for trainers to address in future. Professional training involvement can be enhanced via specialist training such as the EQUIP training the trainers programme evaluated here. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: When training service users and carers to deliver training to mental health professionals, it is important that service users are equipped to deal with resistance from staff. It is important that service user and carer roles are negotiated and agreed prior to delivering training to healthcare professionals to accommodate individual preferences and allay anxieties. Training for service users and carers must be offered

  18. Collective contract in thermal equipment mounting process at the Balakovo NPP

    International Nuclear Information System (INIS)

    Shpol, E.A.; Goryashchenko, Yu.N.

    1986-01-01

    Experience of collective contract introduction into thermal equipment mounting process at the Balakovo NPP is briefly described.4627 thousand roubles are utilized and 45.6% of annual volume of works are made using the collective contract method in 1984 during reactor room construction at the Balakovo-1 NPP. Cost of works are reduced by 137.8 thousand roubles. The conclusion is made that the formation of large teams ( 45-70 men ) promotes labour productivity increase as well as high quality of works

  19. About Economy of Fuel at Thermal Power Stations due to Optimization of Utilization Diagram of Power-Generating Equipment

    Directory of Open Access Journals (Sweden)

    M. V. Svechko

    2008-01-01

    Full Text Available Problems of rational fuel utilization becomes more and more significant especially for thermal power stations (TPS. Thermal power stations have complicated starting-up diagrams and utilization modes of their technological equipment. Method of diagram optimization of TPS equipment utilization modes has been developed. The method is based on computer analytical model with application of spline-approximation of power equipment characteristics. The method allows to economize fuel consumption at a rate of 15-20 % with accuracy of the predicted calculation not more than 0.25 %.

  20. Iterative Relay Scheduling with Hybrid ARQ under Multiple User Equipment (Type II) Relay Environments

    KAUST Repository

    Nam, Sung Sik; Alouini, Mohamed-Slim; Choi, Seyeong

    2018-01-01

    -generation cellular systems (e.g., LTE-Advanced and beyond). The proposed IRS-HARQ aims to increase the achievable data rate by iteratively scheduling a relatively better UE relay closer to the end user in a probabilistic sense, provided that the relay-to-end user

  1. Localization of thermal anomalies in electrical equipment using Infrared Thermography and support vector machine

    Science.gov (United States)

    Laib dit Leksir, Y.; Mansour, M.; Moussaoui, A.

    2018-03-01

    Analysis and processing of databases obtained from infrared thermal inspections made on electrical installations require the development of new tools to obtain more information to visual inspections. Consequently, methods based on the capture of thermal images show a great potential and are increasingly employed in this field. However, there is a need for the development of effective techniques to analyse these databases in order to extract significant information relating to the state of the infrastructures. This paper presents a technique explaining how this approach can be implemented and proposes a system that can help to detect faults in thermal images of electrical installations. The proposed method classifies and identifies the region of interest (ROI). The identification is conducted using support vector machine (SVM) algorithm. The aim here is to capture the faults that exist in electrical equipments during an inspection of some machines using A40 FLIR camera. After that, binarization techniques are employed to select the region of interest. Later the comparative analysis of the obtained misclassification errors using the proposed method with Fuzzy c means and Ostu, has also be addressed.

  2. Prediction of Maintenance Period of Equipment Through Risk Assessment of Thermal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Song, Gee Wook; Kim, Bum Shin; Choi, Woo Song; Park, Myung Soo [KEPCO Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    Risk-based inspection (RBI) is a well-known method that is used to optimize inspection activities based on risk analysis in order to identify the high-risk components of major facilities such as power plants. RBI, when implemented and maintained properly, improves plant reliability and safety while reducing unplanned outages and repair costs. Risk is given by the product of the probability of failure (Pof) and the consequence of failure (COF). A semi-quantitative method is generally used for risk assessment. Semi-quantitative risk assessment complements the low accuracy of qualitative risk assessment and the high expense and long calculation time of quantitative risk assessment. The first step of RB I is to identify important failure modes and causes in the equipment. Once these are defined, the Pof and COF can be assessed for each failure. During Pof and COF assessment, an effective inspection method and range can be easily found. In this paper, the calculation of the Pof is improved for accurate risk assessment. A modified semi-quantitative risk assessment was carried out for boiler facilities of thermal power plants, and the next maintenance schedules for the equipment were decided.

  3. Prediction of Maintenance Period of Equipment Through Risk Assessment of Thermal Power Plants

    International Nuclear Information System (INIS)

    Song, Gee Wook; Kim, Bum Shin; Choi, Woo Song; Park, Myung Soo

    2013-01-01

    Risk-based inspection (RBI) is a well-known method that is used to optimize inspection activities based on risk analysis in order to identify the high-risk components of major facilities such as power plants. RBI, when implemented and maintained properly, improves plant reliability and safety while reducing unplanned outages and repair costs. Risk is given by the product of the probability of failure (Pof) and the consequence of failure (COF). A semi-quantitative method is generally used for risk assessment. Semi-quantitative risk assessment complements the low accuracy of qualitative risk assessment and the high expense and long calculation time of quantitative risk assessment. The first step of RB I is to identify important failure modes and causes in the equipment. Once these are defined, the Pof and COF can be assessed for each failure. During Pof and COF assessment, an effective inspection method and range can be easily found. In this paper, the calculation of the Pof is improved for accurate risk assessment. A modified semi-quantitative risk assessment was carried out for boiler facilities of thermal power plants, and the next maintenance schedules for the equipment were decided

  4. Users manual. Pursuit program of use licenses of radioactive material or generator equipment of ionizing radiations

    International Nuclear Information System (INIS)

    Becerril M, V.M.; Villarreal, J.E.

    1992-05-01

    The objective of the program 'Databases for the pursuit of licenses of use of radioactive material', it consists on the application of a computer system carried out in dbase IV that it allows the control of the all the information related with those licenses for use, possession and storage of radioactive material or generator equipment of ionizing radiations. (Author)

  5. The importance of social networks in their association to drug equipment sharing among injection drug users: a review.

    Science.gov (United States)

    De, Prithwish; Cox, Joseph; Boivin, Jean-François; Platt, Robert W; Jolly, Ann M

    2007-11-01

    To examine the scientific evidence regarding the association between characteristics of social networks of injection drug users (IDUs) and the sharing of drug injection equipment. A search was performed on MEDLINE, EMBASE, BIOSIS, Current Contents, PsycINFO databases and other sources to identify published studies on social networks of IDUs. Papers were selected based on their examination of social network factors in relation to the sharing of syringes and drug preparation equipment (e.g. containers, filters, water). Additional relevant papers were found from the reference list of identified articles. Network correlates of drug equipment sharing are multi-factorial and include structural factors (network size, density, position, turnover), compositional factors (network member characteristics, role and quality of relationships with members) and behavioural factors (injecting norms, patterns of drug use, severity of drug addiction). Factors appear to be related differentially to equipment sharing. Social network characteristics are associated with drug injection risk behaviours and should be considered alongside personal risk behaviours in prevention programmes. Recommendations for future research into the social networks of IDUs are proposed.

  6. Experience of Implementing a Distributed Control System for Thermal and Mechanical and Electrical Equipment at the South-West CHP

    Energy Technology Data Exchange (ETDEWEB)

    Babkin, K. V., E-mail: babkin@uztec.ru; Tsvetkov, M. S.; Kostyuk, R. I.; Chugin, A. V. [SC “South-West CHP” (Russian Federation); Bilenko, V. A.; Molchanov, K. A.; Fedunov, V. V. [JSC “Interautomatika” (Russian Federation)

    2015-01-15

    Results of implementing an SPPA-T3000-based unified distributed control system for thermal and mechanical and electrical equipment at the South-West CHP are discussed. Hardware solutions for integration with local control systems, control of electrical equipment in compliance with the standards IEC 61850, Modbus RTU, and communication between the plant control system and the System Operator of the Unified Power System are described.

  7. Experience of Implementing a Distributed Control System for Thermal and Mechanical and Electrical Equipment at the South-West CHP

    International Nuclear Information System (INIS)

    Babkin, K. V.; Tsvetkov, M. S.; Kostyuk, R. I.; Chugin, A. V.; Bilenko, V. A.; Molchanov, K. A.; Fedunov, V. V.

    2015-01-01

    Results of implementing an SPPA-T3000-based unified distributed control system for thermal and mechanical and electrical equipment at the South-West CHP are discussed. Hardware solutions for integration with local control systems, control of electrical equipment in compliance with the standards IEC 61850, Modbus RTU, and communication between the plant control system and the System Operator of the Unified Power System are described

  8. DETERMINING OF THERMAL STABILITY OF EXPLOSIVES FOR CIVIL USES MODERN EQUIPMENT EQUIPPED WITH AUTOMATIC TEMPERATURE AND PRESSURE

    Directory of Open Access Journals (Sweden)

    Gabriel VASILESCU

    2015-07-01

    Full Text Available Thermal stability of explosives for civil use is a key security parameter. When the explosive is exposed to high tempera-tures in a given period of time can lead to undesirable phenomena such as decomposing or even very dangerous as un-controlled detonation.

  9. USER AND 3RD-PARTY INVOLVEMENT IN DEVELOPING MEDICAL EQUIPMENT INNOVATIONS

    NARCIS (Netherlands)

    BIEMANS, WG

    The development of innovations is increasingly portrayed as a dynamic interplay between two or more actors. This started with the seminal work of von Hippel concerning the role of users during the initial stages of the development cycle. Subsequent studies by numerous academics demonstrated the

  10. Radiation effects on electronic equipment: a designers'/users' guide for the nuclear power industry

    International Nuclear Information System (INIS)

    Sharp, R.E.; Garlick, D.R.

    1994-01-01

    The Designers'/Users' Guide to the effects of radiation on electronics is published by the Radiation Testing Service of AEA Technology. The aim of the Guide is to document the available information that we have generated and collected over some ten years whilst operating as a radiation effects and design consultancy to the nuclear power industry. We hope that this will enable workers within the industry better to understand the likely effects of radiation on the system or plant being designed and so minimise the problems that can arise. (Author)

  11. Environmental equipment for usages of FEM software. ADVENTURE system user's guide

    International Nuclear Information System (INIS)

    Yamasaki, Ichirou; Yoshimura, Shinobu

    2003-05-01

    The community softwares, databases, and other various tools have been installed in the ITBL environment by the Office of ITBL Promotion as a common utility property for each research field. Among those softwares, Finite Element Method (FEM) code, Adventure (which was originally developed by Prof. Yoshimura, the University of Tokyo), is provided as one of structure analysis programs for ITBL users. The code is well known to possess a high performance ability for parallel processing, especially for massively parallel environments. In this report, a chain of processes for usages of the system as well as the installation method to PC cluster are described. (author)

  12. Environmental equipment for usages of FEM software. ADVENTURE system user's guide

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Ichirou [Japan Atomic Energy Research Inst., Center for Promotion of Computional Science and Engineering, Kizu, Kyoto (Japan); Yoshimura, Shinobu [Tokyo Univ., Tokyo (Japan)

    2003-05-01

    The community softwares, databases, and other various tools have been installed in the ITBL environment by the Office of ITBL Promotion as a common utility property for each research field. Among those softwares, Finite Element Method (FEM) code, Adventure (which was originally developed by Prof. Yoshimura, the University of Tokyo), is provided as one of structure analysis programs for ITBL users. The code is well known to possess a high performance ability for parallel processing, especially for massively parallel environments. In this report, a chain of processes for usages of the system as well as the installation method to PC cluster are described. (author)

  13. Emergency Response Equipment and Related Training: Airborne Radiological Computer System (Model II) user's manual

    International Nuclear Information System (INIS)

    David P. Colton

    2007-01-01

    The materials included in the Airborne Radiological Computer System, Model-II (ARCS-II) were assembled with several considerations in mind. First, the system was designed to measure and record the airborne gamma radiation levels and the corresponding latitude and longitude coordinates, and to provide a first overview look of the extent and severity of an accident's impact. Second, the portable system had to be light enough and durable enough that it could be mounted in an aircraft, ground vehicle, or watercraft. Third, the system must control the collection and storage of the data, as well as provide a real-time display of the data collection results to the operator. The notebook computer and color graphics printer components of the system would only be used for analyzing and plotting the data. In essence, the provided equipment is composed of an acquisition system and an analysis system. The data can be transferred from the acquisition system to the analysis system at the end of the data collection or at some other agreeable time

  14. Thermal Adaptation Methods of Urban Plaza Users in Asia's Hot-Humid Regions: A Taiwan Case Study.

    Science.gov (United States)

    Wu, Chen-Fa; Hsieh, Yen-Fen; Ou, Sheng-Jung

    2015-10-27

    Thermal adaptation studies provide researchers great insight to help understand how people respond to thermal discomfort. This research aims to assess outdoor urban plaza conditions in hot and humid regions of Asia by conducting an evaluation of thermal adaptation. We also propose that questionnaire items are appropriate for determining thermal adaptation strategies adopted by urban plaza users. A literature review was conducted and first hand data collected by field observations and interviews used to collect information on thermal adaptation strategies. Item analysis--Exploratory Factor Analysis (EFA) and Confirmatory Factor Analysis (CFA)--were applied to refine the questionnaire items and determine the reliability of the questionnaire evaluation procedure. The reliability and validity of items and constructing process were also analyzed. Then, researchers facilitated an evaluation procedure for assessing the thermal adaptation strategies of urban plaza users in hot and humid regions of Asia and formulated a questionnaire survey that was distributed in Taichung's Municipal Plaza in Taiwan. Results showed that most users responded with behavioral adaptation when experiencing thermal discomfort. However, if the thermal discomfort could not be alleviated, they then adopted psychological strategies. In conclusion, the evaluation procedure for assessing thermal adaptation strategies and the questionnaire developed in this study can be applied to future research on thermal adaptation strategies adopted by urban plaza users in hot and humid regions of Asia.

  15. TACT1- TRANSIENT THERMAL ANALYSIS OF A COOLED TURBINE BLADE OR VANE EQUIPPED WITH A COOLANT INSERT

    Science.gov (United States)

    Gaugler, R. E.

    1994-01-01

    As turbine-engine core operating conditions become more severe, designers must develop more effective means of cooling blades and vanes. In order to design reliable, cooled turbine blades, advanced transient thermal calculation techniques are required. The TACT1 computer program was developed to perform transient and steady-state heat-transfer and coolant-flow analyses for cooled blades, given the outside hot-gas boundary condition, the coolant inlet conditions, the geometry of the blade shell, and the cooling configuration. TACT1 can analyze turbine blades, or vanes, equipped with a central coolant-plenum insert from which coolant-air impinges on the inner surface of the blade shell. Coolant-side heat-transfer coefficients are calculated with the heat transfer mode at each station being user specified as either impingement with crossflow, forced convection channel flow, or forced convection over pin fins. A limited capability to handle film cooling is also available in the program. The TACT1 program solves for the blade temperature distribution using a transient energy equation for each node. The nodal energy balances are linearized, one-dimensional, heat-conduction equations which are applied at the wall-outer-surface node, at the junction of the cladding and the metal node, and at the wall-inner-surface node. At the mid-metal node a linear, three-dimensional, heat-conduction equation is used. Similarly, the coolant pressure distribution is determined by solving the set of transfer momentum equations for the one-dimensional flow between adjacent fluid nodes. In the coolant channel, energy and momentum equations for one-dimensional compressible flow, including friction and heat transfer, are used for the elemental channel length between two coolant nodes. The TACT1 program first obtains a steady-state solution using iterative calculations to obtain convergence of stable temperatures, pressures, coolant-flow split, and overall coolant mass balance. Transient

  16. User's manual for computer code SOLTES-1 (simulator of large thermal energy systems)

    International Nuclear Information System (INIS)

    Fewell, M.E.; Grandjean, N.R.; Dunn, J.C.; Edenburn, M.W.

    1978-09-01

    SOLTES simulates the steady-state response of thermal energy systems to time-varying data such as weather and loads. Thermal energy system models of both simple and complex systems can easily be modularly constructed from a library of routines. These routines mathematically model solar collectors, pumps, switches, thermal energy storage, thermal boilers, auxiliary boilers, heat exchangers, extraction turbines, extraction turbine/generators, condensers, regenerative heaters, air conditioners, heating and cooling of buildings, process vapor, etc.; SOLTES also allows user-supplied routines. The analyst need only specify fluid names to obtain readout of property data for heat-transfer fluids and constants that characterize power-cycle working fluids from a fluid property data bank. A load management capability allows SOLTES to simulate total energy systems that simultaneously follow heat and power loads and demands. Generalized energy accounting is available, and values for system performance parameters may be automatically determined by SOLTES. Because of its modularity and flexibility, SOLTES can be used to simulate a wide variety of thermal energy systems such as solar power/total energy, fossil fuel power plants/total energy, nuclear power plants/total energy, solar energy heating and cooling, geothermal energy, and solar hot water heaters

  17. Improvements in Thermal Performance of Mango Hot-water Treatment Equipments: Data Analysis, Mathematical Modelling and Numerical-computational Simulation

    Directory of Open Access Journals (Sweden)

    Elder M. Mendoza Orbegoso

    2017-06-01

    Full Text Available Mango is one of the most popular and best paid tropical fruits in worldwide markets, its exportation is regulated within a phytosanitary quality control for killing the “fruit fly”. Thus, mangoes must be subject to hot-water treatment process that involves their immersion in hot water over a period of time. In this work, field measurements, analytical and simulation studies are developed on available hot-water treatment equipment called “Original” that only complies with United States phytosanitary protocols. These approaches are made to characterize the fluid-dynamic and thermal behaviours that occur during the mangoes’ hot-water treatment process. Then, analytical model and Computational fluid dynamics simulations are developed for designing new hot-water treatment equipment called “Hybrid” that simultaneously meets with both United States and Japan phytosanitary certifications. Comparisons of analytical results with data field measurements demonstrate that “Hybrid” equipment offers a better fluid-dynamic and thermal performance than “Original” ones.

  18. VIPRE-01: a thermal-hydraulic analysis code for reactor cores. Volume 2. User's manual

    International Nuclear Information System (INIS)

    Cuta, J.M.; Koontz, A.S.; Stewart, C.W.; Montgomery, S.D.

    1983-04-01

    VIPRE (Versatile Internals and Component Program for Reactors; EPRI) has been developed for nuclear power utility thermal-hydraulic analysis applications. It is designed to help evaluate nuclear energy reactor core safety limits including minimum departure from nucleate boiling ratio (MDNBR), critical power ratio (CPR), fuel and clad temperatures, and coolant state in normal operation and assumed accident conditions. This volume (Volume 2: User's Manual) describes the input requirements of VIPRE and its auxiliary programs, SPECSET, ASP and DECCON, and lists the input instructions for each code

  19. Joint energy demand and thermal comfort optimization in photovoltaic-equipped interconnected microgrids

    NARCIS (Netherlands)

    Baldi, S.; Karagevrekis, A; Michailidis, IT; Kosmatopoulos, EB

    2015-01-01

    Electrical smart microgrids equipped with small-scale renewable-energy generation systems are emerging progressively as an alternative or an enhancement to the central electrical grid: due to the intermittent nature of the renewable energy sources, appropriate algorithms are required to integrate

  20. Methodology of Supervision by Analysis of Thermal Flux for Thermal Conduction of a Batch Chemical Reactor Equipped with a Monofluid Heating/Cooling System

    Directory of Open Access Journals (Sweden)

    Ghania Henini

    2012-01-01

    Full Text Available We present the thermal behavior of a batch reactor to jacket equipped with a monofluid heating/cooling system. Heating and cooling are provided respectively by an electrical resistance and two plate heat exchangers. The control of the temperature of the reaction is based on the supervision system. This strategy of management of the thermal devices is based on the usage of the thermal flux as manipulated variable. The modulation of the monofluid temperature by acting on the heating power or on the opening degrees of an air-to-open valve that delivers the monofluid to heat exchanger. The study shows that the application of this method for the conduct of the pilot reactor gives good results in simulation and that taking into account the dynamics of the various apparatuses greatly improves ride quality of conduct. In addition thermal control of an exothermic reaction (mononitration shows that the consideration of heat generated in the model representation improve the results by elimination any overshooting of the set-point temperature.

  1. Porosity influence of power generating equipment structural materials on its thermoelastic characteristics and thermal conductivity

    Science.gov (United States)

    Zarubin, V. S.; Sergeeva, E. S.

    2017-11-01

    This paper outlines simulation models that represent the quantitative interdependencies between the thermal conductivity and the thermoelastic properties of composites, on the one hand, and their porous structure and matrix properties, as well as the volume fraction of their reinforcing inclusions, on the other hand. As the reinforcing inclusions, randomly-oriented anisotropic single-wall carbon nanotubes (SWNT) are taken. The key means for constructing the simulation models are the self-matching method and the dual variational formulation of the thermal conductivity/thermoelasticity problem for a non-homogeneous solid body. With the simulation models presented below, it is possible to estimate the effect the nanocomposite porosity has on the thermoelastic properties and thermal conductivity of nanocomposites.

  2. Preliminary degradation process study of infectious biological waste in a 5 k W thermal plasma equipment

    International Nuclear Information System (INIS)

    Xochihua S M, M.C.

    1997-01-01

    This work is a preliminary study of infectious biological waste degradation process by thermal plasma and was made in Thermal Plasma Applications Laboratory of Environmental Studies Department of the National Institute of Nuclear Research (ININ). Infectious biological waste degradation process is realized by using samples such polyethylene, cotton, glass, etc., but the present study scope is to analyze polyethylene degradation process with mass and energy balances involved. Degradation method is realized as follow: a polyethylene sample is put in an appropriated crucible localized inside a pyrolysis reactor chamber, the plasma jet is projected to the sample, by the pyrolysis phenomena the sample is degraded into its constitutive particles: carbon and hydrogen. Air was utilized as a recombination gas in order to obtain the higher percent of CO 2 if amount of O 2 is greater in the recombination gas, the CO generation is reduced. The effluent gases of exhaust pyrolysis reactor through are passed through a heat exchanger to get cooled gases, the temperature water used is 15 Centigrade degrees. Finally the gases was tried into absorption tower with water as an absorbent fluid. Thermal plasma degradation process is a very promising technology, but is necessary to develop engineering process area to avail all advantages of thermal plasma. (Author)

  3. Quick Maintenance for High Voltage Equipment with the New Not Toxic Boron Nitride Powder (BN100) Superior Thermal Conductive and Lightweight Filler

    National Research Council Canada - National Science Library

    Boer, Fabrizio

    2005-01-01

    .... The BN100 superior thermal conductive and lightweight filler technology is a new filler technology, that not only lets Users a full access for maintenance because cure-free being compounded by loose...

  4. A model predictive framework of Ground Source Heat Pump coupled with Aquifer Thermal Energy Storage System in heating and cooling equipment of a building

    NARCIS (Netherlands)

    Rostampour Samarin, V.; Bloemendal, J.M.; Keviczky, T.

    2017-01-01

    This paper presents a complete model of a building heating and cooling equipment and a ground source heat pump (GSHP) coupled with an aquifer thermal energy storage (ATES) system. This model contains detailed
    mathematical representations of building thermal dynamics, ATES system dynamics, heat

  5. Thermal vacuum test of space equipment: tests of SIR-2 instrument Chandrayaan-1 mission

    Science.gov (United States)

    Sitek, P.

    2008-11-01

    We describe the reasons of proceeding Thermal-Vacuum tests for space electronic. We will answer on following questions: why teams are doing TV tests, what kind of phases should be simulated, which situations are the most critical during TV tests, what kind of results should be expected, which errors can be detect. As an example, will be shown TV-test of SIR-2 instrument for Chandrayaan-1 moon mission.

  6. Combustion and regulations. Impacts of new regulations on medium-power thermal equipment (boilers, engines, turbines, dryers and furnaces); Combustion et reglementation. Incidences des nouvelles reglementations sur les equipements thermiques de moyenne puissance (chaudieres, moteurs, turbines, secheurs et fours)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    This conference is composed of 20 papers on the influence of French and European new pollution regulations on medium size thermal equipment such as boilers, engines, turbines, dryers and furnaces. It is discussed what is going to change with new regulations, how they will apply to existing plants, what will be the impact on future equipment costs. The evolution of energy suppliers and equipment manufacturers facing these new regulations is also examined: fuel substitution, improvements in turbines and engines with water injection and special chambers, diesel engine control, lean mixtures and electronic control for gas engines... Means for reducing SOx, NOx and ash emission levels in boilers are also examined

  7. Thermal Insulation System Analysis Tool (TISTool) User's Manual. Version 1.0.0

    Science.gov (United States)

    Johnson, Wesley; Fesmire, James; Leucht, Kurt; Demko, Jonathan

    2010-01-01

    The Thermal Insulation System Analysis Tool (TISTool) was developed starting in 2004 by Jonathan Demko and James Fesmire. The first edition was written in Excel and Visual BasIc as macros. It included the basic shapes such as a flat plate, cylinder, dished head, and sphere. The data was from several KSC tests that were already in the public literature realm as well as data from NIST and other highly respectable sources. More recently, the tool has been updated with more test data from the Cryogenics Test Laboratory and the tank shape was added. Additionally, the tool was converted to FORTRAN 95 to allow for easier distribution of the material and tool. This document reviews the user instructions for the operation of this system.

  8. Evaluating and Quantifying User and Carer Involvement in Mental Health Care Planning (EQUIP: Co-Development of a New Patient-Reported Outcome Measure.

    Directory of Open Access Journals (Sweden)

    Penny Bee

    Full Text Available International and national health policy seeks to increase service user and carer involvement in mental health care planning, but suitable user-centred tools to assess the success of these initiatives are not yet available. The current study describes the development of a new reliable and valid, interval-scaled service-user and carer reported outcome measure for quantifying user/carer involvement in mental health care planning. Psychometric development reduced a 70-item item bank to a short form questionnaire using a combination of Classical Test, Mokken and Rasch Analyses. Test-retest reliability was calculated using t-tests of interval level scores between baseline and 2-4 week follow-up. Items were worded to be relevant to both service users and carers. Nine items were removed following cognitive debriefing with a service user and carer advisory group. An iterative process of item removal reduced the remaining 61 items to a final 14-item scale. The final scale has acceptable scalability (Ho = .69, reliability (alpha = .92, fit to the Rasch model (χ2(70 = 97.25, p = .02, and no differential item functioning or locally dependent items. Scores remained stable over the 4 week follow-up period, indicating good test-retest reliability. The 'Evaluating the Quality of User and Carer Involvement in Care Planning (EQUIP' scale displays excellent psychometric properties and is capable of unidimensional linear measurement. The scale is short, user and carer-centred and will be of direct benefit to clinicians, services, auditors and researchers wishing to quantify levels of user and carer involvement in care planning.

  9. Intermediate Compound Preparation Using Modified External Gelation Method and Thermal Treatment Equipment Development for UCO Kernel

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kyung Chai; Eom, Sung Ho; Kim, Yeon Ku; Yeo, Seoung Hwan; Kim, Young Min; Cho, Moon Sung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    VHTR (Very High Temperature Gas Reactor) fuel technology is being actively developed in the US, China, Japan, and Korea for a Next Generation Nuclear Plant (NGNP). The concept of fuel of a VHTR is based on a sphere kernel of UO{sub 2} or UCO, with multiple coating layers to create a gas-tight particle. The fuel particle of a VHTR in the US is based on microspheres containing a UCO, mixture compound of UO{sub 2} and UC{sub 2} , coated particles with multi carbon layers and a SiC layer. This was first prepared through an internal gelation method at ORNL in the late 1970s. This study presents; (1) C-ADU gel particles were prepared using a modified sol-gel process. The particles fabricated with a KAERI-established gelation and AWD processes showed good sphericity and no cracks were found on the surfaces. (2) High temperature rotating furnace was designed and fabricated in our laboratory, and the maximum operation temperature was about 2000℃. The furnace was equipped with Mo crucible and graphite heating system, and now it is being operated. (3) Well-prepared C-ADU gel particles were converted into UCO compounds using high temperature rotating furnace, and the physical properties of the UCO kernels will be analyzed.

  10. Thermal and catalytic pyrolysis of a mixture of plastics from small waste electrical and electronic equipment (WEEE).

    Science.gov (United States)

    Santella, Chiara; Cafiero, Lorenzo; De Angelis, Doina; La Marca, Floriana; Tuffi, Riccardo; Vecchio Ciprioti, Stefano

    2016-08-01

    Pyrolysis seems a promising route for recycling of heterogeneous, contaminated and additives containing plastics from waste electrical and electronic equipment (WEEE). This study deals with the thermal and catalytic pyrolysis of a synthetic mixture containing real waste plastics, representative of polymers contained in small WEEE. Two zeolite-based catalysts were used at 400°C: HUSY and HZSM-5 with a high silica content, while three different temperatures were adopted for the thermal cracking: 400, 600 and 800°C. The mass balance showed that the oil produced by pyrolysis is always the main product regardless the process conditions selected, with yields ranging from 83% to 93%. A higher yield was obtained when pyrolysis was carried out with HZSM-5 at 400°C and without catalysts, but at 600 and 800°C. Formation of a significant amount of solid residue (about 13%) is observed using HUSY. The oily liquid product of pyrolysis, analysed by GC-MS and GC-FID, as well as by elemental analysis and for energy content, appeared lighter, less viscous and with a higher concentration of monoaromatics under catalytic condition, if compared to the liquid product derived from thermal degradation at the same temperature. HZSM-5 led to the production of a high yield of styrene (17.5%), while HUSY favoured the formation of ethylbenzene (15%). Energy released by combustion of the oil was around 39MJ/kg, thus suggesting the possibility to exploit it as a fuel, if the recovery of chemical compounds could not be realised. Elemental and proximate analysis of char and GC-TCD analysis of the gas were also performed. Finally, it was estimated to what extent these two products, showing a relevant ability to release energy, could fulfil the energy demand requested in pyrolysis. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. [Prevention of medical device-related adverse events in hospitals: Specifying the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment].

    Science.gov (United States)

    Bohnet-Joschko, Sabine; Zippel, Claus; Siebert, Hartmut

    2015-01-01

    The use and organisation of medical technology has an important role to play for patient and user safety in anaesthesia. Specification of the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment, explore opportunities and challenges for the safe use and organisation of anaesthesia devices. We conducted a literature search in Medline/PubMed for studies dealing with the APS recommendations for the prevention of medical device-related risks in the context of anaesthesia. In addition, we performed an internet search for reports and recommendations focusing on the use and organisation of medical devices in anaesthesia. Identified studies were grouped and assigned to the recommendations. The division into users and operators was maintained. Instruction and training in anaesthesia machines is sometimes of minor importance. Failure to perform functional testing seems to be a common cause of critical incidents in anaesthesia. There is a potential for reporting to the federal authority. Starting points for the safe operation of anaesthetic devices can be identified, in particular, at the interface of staff, organisation, and (anaesthesia) technology. The APS recommendations provide valuable information on promoting the safe use of medical devices and organisation in anaesthesia. The focus will be on risks relating to the application as well as on principles and materials for the safe operation of anaesthesia equipment. Copyright © 2015. Published by Elsevier GmbH.

  12. Thermal Integration of CO{sub 2} Compression Processes with Coal-Fired Power Plants Equipped with Carbon Capture

    Energy Technology Data Exchange (ETDEWEB)

    Edward Levy

    2012-06-29

    Coal-fired power plants, equipped either with oxycombustion or post-combustion CO{sub 2} capture, will require a CO{sub 2} compression system to increase the pressure of the CO{sub 2} to the level needed for sequestration. Most analyses show that CO{sub 2} compression will have a significant effect on parasitic load, will be a major capital cost, and will contribute significantly to reduced unit efficiency. This project used first principle engineering analyses and computer simulations to determine the effects of utilizing compressor waste heat to improve power plant efficiency and increase net power output of coal-fired power plants with carbon capture. This was done for units with post combustion solvent-based CO{sub 2} capture systems and for oxyfired power plants, firing bituminous, PRB and lignite coals. The thermal integration opportunities analyzed for oxycombustion capture are use of compressor waste heat to reheat recirculated flue gas, preheat boiler feedwater and predry high-moisture coals prior to pulverizing the coal. Among the thermal integration opportunities analyzed for post combustion capture systems are use of compressor waste heat and heat recovered from the stripper condenser to regenerate post-combustion CO{sub 2} capture solvent, preheat boiler feedwater and predry high-moisture coals. The overall conclusion from the oxyfuel simulations is that thermal integration of compressor heat has the potential to improve net unit heat rate by up to 8.4 percent, but the actual magnitude of the improvement will depend on the type of heat sink used and to a lesser extent, compressor design and coal rank. The simulations of a unit with a MEA post combustion capture system showed that thermal integration of either compressor heat or stripper condenser heat to preheat boiler feedwater would result in heat rate improvements from 1.20 percent to 4.19 percent. The MEA capture simulations further showed that partial drying of low rank coals, done in combination

  13. THEAP-I: A computer program for thermal hydraulic analysis of a thermally interacting channel bundle of complex geometry. Code description and user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Bartzis, J G; Megaritou, A; Belessiotis, V

    1987-09-01

    THEAP-I is a computer code developed in NRCPS `DEMOCRITUS` with the aim to contribute to the safety analysis of the open pool research reactors. THEAP-I is designed for three dimensional, transient thermal/hydraulic analysis of a thermally interacting channel bundle totally immersed into water or air, such as the reactor core. In the present report the mathematical and physical models and methods of the solution are given as well as the code description and the input data. A sample problem is also included, refering to the Greek Research Reactor analysis, under an hypothetical severe loss of coolant accident.

  14. A randomized intervention trial to reduce the lending of used injection equipment among injection drug users infected with hepatitis C.

    Science.gov (United States)

    Latka, Mary H; Hagan, Holly; Kapadia, Farzana; Golub, Elizabeth T; Bonner, Sebastian; Campbell, Jennifer V; Coady, Micaela H; Garfein, Richard S; Pu, Minya; Thomas, Dave L; Thiel, Thelma K; Strathdee, Steffanie A

    2008-05-01

    We evaluated the efficacy of a peer-mentoring behavioral intervention designed to reduce risky distributive injection practices (e.g., syringe lending, unsafe drug preparation) among injection drug users with hepatitis C virus (HCV) infection. A randomized trial with a time-equivalent attention-control group was conducted among 418 HCV-positive injection drug users aged 18 to 35 years in 3 US cities. Participants reported their injection-related behaviors at baseline and at 3- and 6-month follow-ups. Compared with the control group, intervention-group participants were less likely to report distributive risk behaviors at 3 months (odds ratio [OR]=0.46; 95% confidence interval [CI]=0.27, 0.79) and 6 months (OR=0.51; 95% CI=0.31, 0.83), a 26% relative risk reduction, but were no more likely to cite their HCV-positive status as a reason for refraining from syringe lending. Effects were strongest among intervention-group participants who had known their HCV-positive status for at least 6 months. Peer mentoring and self-efficacy were significantly increased among intervention-group participants, and intervention effects were mediated through improved self-efficacy. This behavioral intervention reduced unsafe injection practices that may propagate HCV among injection drug users.

  15. Thermal degradation characteristics and products obtained after pyrolysis of specific polymers found in Waste Electrical and Electronic Equipment

    Institute of Scientific and Technical Information of China (English)

    Evangelia C.Vouvoudi; Aristea T.Rousi; Dimitris S.Achilias

    2017-01-01

    Modern societies strongly support the recycling practices over simple waste accumulation due to environmental harm caused.In the framework of sustainable recycling of plastics from WEEE,pyrolysis is proposed here as a means of obtaining secondary value-added products.The aim of this study was to investigate the thermal degradation and the products obtained after pyrolysis of specific polymers found in the plastic part of WEEE,using thermogravimetric analysis and a pyrolizer equipped with a GC/MS.Polymers studied include ABS,HIPS,PC and a blend having a composition similar to that appearing in WEEE.It was found that,PC shows greater heat endurance compared to the other polymers,whereas ABS depolymerizes in three-steps.The existence of several polymers in the blend results in synergistic effects which decrease the onset and final temperature of degradation.Moreover,the fragmentation occurred in the pyrolyzer,at certain temperatures,resulted in a great variety of compounds,depending on the polymer type,such as monomers,aromatic products,phenolic compounds and hydrocarbons.The main conclusion from this investigation is that pyrolysis could be an effective method for the sustainable recycling of the plastic part of WEEE resulting in a mixture of chemicals with varying composition but being excellent to be used as fuel retrieved from secondary recycling sources.

  16. Application of ELD and load forecast in optimal operation of industrial boiler plants equipped with thermal stores

    International Nuclear Information System (INIS)

    Cao Jiacong

    2007-01-01

    Optimal operation of industrial boiler plants with objects of high energy efficiency and low fuel cost is still well worth investigating when energy problem becomes a world's concern, for there are a great number of boiler plants serving industries. The optimization of operation is a measure that is less expensive and easier to carry out than many other measures. Economic load dispatch (ELD) is an effective approach to optimal operation of industrial boiler plants. In the paper a newly developed method referred to as the method of minimum-departure model (MDM) is used in the ELD for boiler plants. It is more convenient for carrying out ELD when boiler plants are equipped with thermal energy stores that usually adopt the working mode of optimal segmentation of a daily load curve. In the case of industrial boiler plants, ELD needs a prerequisite, viz., the accurate load forecast, which is performed using artificial neural networks in this paper. A computer program for the optimal operation was completed and applied to an example, which results the minimum daily fuel cost of the whole boiler plant

  17. Energy saving by means of air conditioning equipment replacement and the household application of thermal insulation; Ahorro de energia electrica por reemplazo de equipos de aire acondicionado y aplicacion de aislamiento termico en viviendas

    Energy Technology Data Exchange (ETDEWEB)

    Peralta Solorio, Jose Luis [Fideicomiso para el Ahorro de la Energia (Mexico)

    2005-07-15

    An extension study of the Financing Program for Energy Saving looked for the evaluation of the electric energy saving potential obtained by the replacement of air conditioning equipment and the application of thermal insulation in 30 houses of two Mexican cities with warmth climate. In a joint effort with Comision Federal de Electricidad the consumption files of the users were analyzed and field measurements of electric demand and of refrigeration were made. As a following step the change of the refrigeration necessities derived from the application of thermal insulation were evaluated as well as the energy efficiency improvement obtained by the substitution of the air conditioning equipment and the favorable results obtained by the implementation of both measures - thermal insulation and change of air conditioning equipment in a joint form. This way, as a conclusion, the optimum sequence of application of these measures is revealed. [Spanish] Un estudio extension del Programa de Financiamiento para el Ahorro de Energia Electrica busco evaluar el potencial de ahorro de energia electrica alcanzado por el reemplazo de equipos de aire acondicionado y la aplicacion de aislamiento termico en 30 viviendas de dos ciudades mexicanas con clima calido. En un esfuerzo conjunto con la Comision Federal de Electricidad se analizaron los historiales de consumo de los usuarios y se efectuaron las mediciones de campo de demanda electrica y de refrigeracion. Como paso siguiente se valoro el cambio en las necesidades de refrigeracion derivado de la aplicacion de aislamiento termico al igual que la mejora en eficiencia energetica obtenida por la sustitucion de aire acondicionado y se identificaron los resultados favorecedores arrojados por la implementacion de ambas medidas -aislamiento termico y cambio de equipo de aire acondicionado- en forma conjunta. De esta manera, como conclusion, se devela la mas optima secuencia de aplicacion de estas medidas.

  18. Open-Source Assisted Laboratory Automation through Graphical User Interfaces and 3D Printers: Application to Equipment Hyphenation for Higher-Order Data Generation.

    Science.gov (United States)

    Siano, Gabriel G; Montemurro, Milagros; Alcaráz, Mirta R; Goicoechea, Héctor C

    2017-10-17

    Higher-order data generation implies some automation challenges, which are mainly related to the hidden programming languages and electronic details of the equipment. When techniques and/or equipment hyphenation are the key to obtaining higher-order data, the required simultaneous control of them demands funds for new hardware, software, and licenses, in addition to very skilled operators. In this work, we present Design of Inputs-Outputs with Sikuli (DIOS), a free and open-source code program that provides a general framework for the design of automated experimental procedures without prior knowledge of programming or electronics. Basically, instruments and devices are considered as nodes in a network, and every node is associated both with physical and virtual inputs and outputs. Virtual components, such as graphical user interfaces (GUIs) of equipment, are handled by means of image recognition tools provided by Sikuli scripting language, while handling of their physical counterparts is achieved using an adapted open-source three-dimensional (3D) printer. Two previously reported experiments of our research group, related to fluorescence matrices derived from kinetics and high-performance liquid chromatography, were adapted to be carried out in a more automated fashion. Satisfactory results, in terms of analytical performance, were obtained. Similarly, advantages derived from open-source tools assistance could be appreciated, mainly in terms of lesser intervention of operators and cost savings.

  19. Proceedings of the Government Users Workshop on Ground Penetrating Radar Applications and Equipment 26-27 March 1992 Vicksburg, Mississippi

    Science.gov (United States)

    1992-12-01

    Allison P.O. Box 946 USDA Tifton , GA 31794 Box 946 Phone: 912-386-3899 Tifton , GA 31794 FAX: 912-386-7215 Phone: 912-386-7075 FAX: 912-386-7215 Paul...FAX: 603-889-3984 FAX: 071-724-1433 Ricky Fletcher S. V. Cosvay USDA-ARS-SEWRL Sensors and Software, Inc. Rt. 4, Box 1390 5566 Tomken Road Tifton , GA ... Tifton , GA 31793 Phone: 305-634-4507 Phone: 912-386-7174 FAX: 305-635-4901 FAX: 912-386-7215 8 GOVERNMENT USERS WORKSHOP ON GROUND PENETRATING RADAR

  20. User effects on the thermal-hydraulic transient system code calculations

    International Nuclear Information System (INIS)

    Aksan, S.N.; D'Auria, F.; Staedtke, H.

    1993-01-01

    In the paper, the results of the investigations on the user effects for the thermalhydraulic transient system codes will be presented and discussed on the basis of some case studies. The general findings of the investigations show that in addition to user effects, there are other reasons that affect the results of the calculations and which are hidden under user effects. Both the hidden factors and the direct user effects will be discussed in detail and general recommendations and conclusions will be presented to control and limit them. (orig.)

  1. Designing for an imagined user: Provision for thermal comfort in energy-efficient extra-care housing

    International Nuclear Information System (INIS)

    Lewis, Alan

    2015-01-01

    Regarded as one solution to the problem of how to enable older people to retain their independence, extra-care housing, where each resident has their own self-contained dwelling and access to communal facilities and to care, has received extensive funding in recent years. Implicit in the concept of specialist housing is the notion of ‘special’ occupants, imagined older people. Adopting a socio-technical approach, this paper considers how ideas about ageing inform those aspects of extra-care-housing-design that relate to thermal comfort. The paper draws on semi-structured interviews with 13 people involved in the design, development and management of UK-based extra-care housing. Participants characterised imagined occupants as vulnerable to cold, at risk from fuel poverty and liable to be burned by hot surfaces or fall from high windows. These user representations were reportedly inscribed into the design of extra-care housing schemes through the inclusion of building features such as communal heating, under-floor heating, restricted window opening and heated corridors. The utilisation of stereotypical user representations of older people raises questions, given that older people's thermal comfort needs can be highly diverse. The paper explores the implications for energy demand. -- Highlights: •Explores the factors that condition energy demand in older people's housing. •Considers how user representations are scripted into building design. •Older occupants characterised as vulnerable to cold and having low incomes. •These user representations affect selection of thermal technologies. •Priority given to keeping occupants warm, leading to possible risk of overheating

  2. Statistical analysis of the behaviour of the mechanical equipment of EDFs power plants - evaluation of the availability and safety of thermal and nuclear units

    International Nuclear Information System (INIS)

    Procaccia, H.; Brillon, A.; Cravero, M.; Lucenet, G.

    1975-01-01

    The investigation and research directorate of EDF has undertaken a statistical analysis of the behaviour of large mechanical equipment at conventional power stations during the ten years following the operating reports of these stations. It has thus been possible to determine the intrinsic reliability, the failure rate, the mean repair time, and the mean good operating time of feed water reheating points, power turbines, pumps and boilers of the various EDF plants (125 and 250 MW) leading to a consideration of the feasibility of an extrapolation to present and future plants. Based on these elementary investigation two methods of calculation have been developed. One is used to assess the overall availability of a thermal or nuclear power station based on the knowledge of the failure rates of the equipment, each piece of equipment being associated with an idea of its technical importance in the functioning of the equipment. A numerical application is given for 125 and 250 MW conventional plants. The purpose of the other method is to estimate the operational safety of the safety equipment of nuclear power stations, based on the development of tree diagrams for faults in basic equipment. A numerical example is given for the cooling systems for Phenix and for one of the Super Phenix versions. (author)

  3. On results of tests of thermal insulation structural fragments for in-vessel equipment and pipelines of the VG-400 plant on vibrational and acoustic loads

    International Nuclear Information System (INIS)

    Ledenko, S.A.; Andreev, V.A.; Mirenkov, A.F.; Zakharov, V.A.; Suvorov, V.E.; Prokimnov, V.V.

    1990-01-01

    Results of vibrostrength and acoustic fatigue tests of the fragments of thermal insulation for in-vessel equipment and pipelines of the VG-400 reactor are presented. The insulation structure is based on the insulation layer made of steel foil and carbon materials. Weak points in the insulation structure, namely - the welded joints of stiffening ribs - are detected in the course of testing. A conclusion is made on the possibility of vibrational test substitution for the acoustic ones

  4. Multi-criteria evaluation and priority analysis for localization equipment in a thermal power plant using the AHP (analytic hierarchy process)

    International Nuclear Information System (INIS)

    Yagmur, Levent

    2016-01-01

    Ensuring the safety of its energy supply is one of the main issues for newly industrialized/developing countries when utilizing domestic sources for electricity generation. Turkey depends heavily on imported gas to generate electricity, and the ratio of natural gas power generation to total electricity production is nearly 50%. Coal-fired thermal power plants using domestic resources are considered a good option to decrease the large amount of imported natural gas, and to supply a secure energy demand. However, electricity generation from coal-fired power plants using local lignite reserves is not adequate to maintain a secure energy mix and provide sustainable development, as Turkey does not have indigenous energy sector technology. Therefore, technology transfer and its localization are crucial for newly industrialized/developing countries such as Turkey. The aim of this study is to use the analytic hierarchy process to determine a priority analysis in relation to localization equipment for a thermal power plant. Parameters involved, such as readiness of both infrastructure and human resources, manpower as skilled labor, market potential for equipment developed by transferred technology, and competition in global/internal market, are related to localization in thermal power plant technologies, and are considered in relation to the country's technological capability, design ability, possession of materials/equipment, and ability to erect a plant. Results of analysis show that the boiler is the most important piece of equipment in this respect, and that heaters and fans are ranked after the boiler with respect to local conditions. - Highlights: • Localization of foreign technology was determined for developing countries. • An evaluation and priority analysis were performed for parts of a thermal power plant. • Analytic hierarchy process was applied for the hierarchical ordering of parts when transferring technology.

  5. COBRA-SFS [Spent Fuel Storage]: A thermal-hydraulic analysis computer code: Volume 2, User's manual

    International Nuclear Information System (INIS)

    Rector, D.R.; Cuta, J.M.; Lombardo, N.J.; Michener, T.E.; Wheeler, C.L.

    1986-11-01

    COBRA-SFS (Spent Fuel Storage) is a general thermal-hydraulic analysis computer code used to predict temperatures and velocities in a wide variety of systems. The code was refined and specialized for spent fuel storage system analyses for the US Department of Energy's Commercial Spent Fuel Management Program. The finite-volume equations governing mass, momentum, and energy conservation are written for an incompressible, single-phase fluid. The flow equations model a wide range of conditions including natural circulation. The energy equations include the effects of solid and fluid conduction, natural convection, and thermal radiation. The COBRA-SFS code is structured to perform both steady-state and transient calculations; however, the transient capability has not yet been validated. This volume contains the input instructions for COBRA-SFS and an auxiliary radiation exchange factor code, RADX-1. It is intended to aid the user in becoming familiar with the capabilities and modeling conventions of the code

  6. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  7. TPDWR2: thermal power determination for Westinghouse reactors, Version 2. User's guide

    International Nuclear Information System (INIS)

    Kaczynski, G.M.; Woodruff, R.W.

    1985-12-01

    TPDWR2 is a computer program which was developed to determine the amount of thermal power generated by any Westinghouse nuclear power plant. From system conditions, TPDWR2 calculates enthalpies of water and steam and the power transferred to or from various components in the reactor coolant system and to or from the chemical and volume control system. From these results and assuming that the reactor core is operating at constant power and is at thermal equilibrium, TPDWR2 calculates the thermal power generated by the reactor core. TPDWR2 runs on the IBM PC and XT computers when IBM Personal Computer DOS, Version 2.00 or 2.10, and IBM Personal Computer Basic, Version D2.00 or D2.10, are stored on the same diskette with TPDWR2

  8. Integrated Method for Personal Thermal Comfort Assessment and Optimization through Users' Feedback, IoT and Machine Learning: A Case Study †.

    Science.gov (United States)

    Salamone, Francesco; Belussi, Lorenzo; Currò, Cristian; Danza, Ludovico; Ghellere, Matteo; Guazzi, Giulia; Lenzi, Bruno; Megale, Valentino; Meroni, Italo

    2018-05-17

    Thermal comfort has become a topic issue in building performance assessment as well as energy efficiency. Three methods are mainly recognized for its assessment. Two of them based on standardized methodologies, face the problem by considering the indoor environment in steady-state conditions (PMV and PPD) and users as active subjects whose thermal perception is influenced by outdoor climatic conditions (adaptive approach). The latter method is the starting point to investigate thermal comfort from an overall perspective by considering endogenous variables besides the traditional physical and environmental ones. Following this perspective, the paper describes the results of an in-field investigation of thermal conditions through the use of nearable and wearable solutions, parametric models and machine learning techniques. The aim of the research is the exploration of the reliability of IoT-based solutions combined with advanced algorithms, in order to create a replicable framework for the assessment and improvement of user thermal satisfaction. For this purpose, an experimental test in real offices was carried out involving eight workers. Parametric models are applied for the assessment of thermal comfort; IoT solutions are used to monitor the environmental variables and the users' parameters; the machine learning CART method allows to predict the users' profile and the thermal comfort perception respect to the indoor environment.

  9. Thermal conditions within tree cavities in ponderosa pine (Pinus ponderosa) forests: potential implications for cavity users

    Science.gov (United States)

    Vierling, Kerri T.; Lorenz, Teresa J.; Cunningham, Patrick; Potterf, Kelsi

    2017-11-01

    Tree cavities provide critical roosting and breeding sites for multiple species, and thermal environments in these cavities are important to understand. Our objectives were to (1) describe thermal characteristics in cavities between June 3 and August 9, 2014, and (2) investigate the environmental factors that influence cavity temperatures. We placed iButtons in 84 different cavities in ponderosa pine (Pinus ponderosa) forests in central Washington, and took hourly measurements for at least 8 days in each cavity. Temperatures above 40 °C are generally lethal to developing avian embryos, and 18% of the cavities had internal temperatures of ≥ 40 °C for at least 1 h of each day. We modeled daily maximum cavity temperature, the amplitude of daily cavity temperatures, and the difference between the mean internal cavity and mean ambient temperatures as a function of several environmental variables. These variables included canopy cover, tree diameter at cavity height, cavity volume, entrance area, the hardness of the cavity body, the hardness of the cavity sill (which is the wood below the cavity entrance which forms the barrier between the cavity and the external environment), and sill width. Ambient temperature had the largest effect size for maximum cavity temperature and amplitude. Larger trees with harder sills may provide more thermally stable cavity environments, and decayed sills were positively associated with maximum cavity temperatures. Summer temperatures are projected to increase in this region, and additional research is needed to determine how the thermal environments of cavities will influence species occupancy, breeding, and survival.

  10. Parametric performance analysis of a concentrated photovoltaic co-generation system equipped with a thermal storage tank

    International Nuclear Information System (INIS)

    Imtiaz Hussain, M.; Lee, Gwi Hyun

    2015-01-01

    Highlights: • Both thermal and electrical powers varied by changing surface area of collector. • Thermal stratification and total system power were increased at critical flow rate. • Parametric analysis of the CPVC system offers to determine the desired outcome. • Thermal and electrical outputs varied by changing the focal length of Fresnel lens. - Abstract: This article presents a parametric study of a concentrated photovoltaic co-generation (CPVC) system with an attached thermal storage tank. The CPVC system utilized dual-axis tracker and multiple solar energy collector (SEC) modules and forced cooling system. Each SEC module comprised 16 triple-junction solar cells, copper tube absorbers, and 16 Fresnel lenses were aligned against each solar cell. This study investigated all possible parameters that can affect the CPVC system performance, including the collector area, solar irradiation, inlet temperature, and mass flow rate. The surface area of the collector and the thermal power were increased by increasing the number of SEC modules connected in series; however, the electrical power output decreased from the first to the fourth SEC module consecutively. At the measured optimal flow rate, mixing and thermal diffusion in the storage tank were decreased, and the total power generation from the CPVC system was increased. Variations in the thermal and electrical power outputs were also observed when the focal length of the Fresnel lens was changed. This parametric analysis enables the CPVC system to obtain the desired output by varying the combination of operational and geometrical parameters

  11. Recommendations on the choice of gas analysis equipment for systems of continuous monitoring and accounting of emissions from thermal power plants

    Science.gov (United States)

    Kondrat'eva, O. E.; Roslyakov, P. V.; Burdyukov, D. A.; Khudolei, O. D.; Loktionov, O. A.

    2017-10-01

    According to Federal Law no. 219-FZ, dated July 21, 2014, all enterprises that have a significant negative impact on the environment shall continuously monitor and account emissions of harmful substances into the atmospheric air. The choice of measuring equipment that is included in continuous emission monitoring and accounting systems (CEM&ASs) is a complex technical problem; in particular, its solution requires a comparative analysis of gas analysis systems; each of these systems has its advantages and disadvantages. In addition, the choice of gas analysis systems for CEM&ASs should be maximally objective and not depend on preferences of separate experts and specialists. The technique of choosing gas analysis equipment that was developed in previous years at Moscow Power Engineering Institute (MPEI) has been analyzed and the applicability of the mathematical tool of a multiple criteria analysis to choose measuring equipment for the continuous emission monitoring and accounting system have been estimated. New approaches to the optimal choice of gas analysis equipment for systems of the continuous monitoring and accounting of harmful emissions from thermal power plants have been proposed, new criteria of evaluation of gas analysis systems have been introduced, and weight coefficients have been determined for these criteria. The results of this study served as a basis for the Preliminary National Standard of the Russian Federation "Best Available Technologies. Automated Systems of Continuous Monitoring and Accounting of Emissions of Harmful (Polluting) Substances from Thermal Power Plants into the Atmospheric Air. Basic Requirements," which was developed by the Moscow Power Engineering Institute, National Research University, in cooperation with the Council of Power Producers and Strategic Electric Power Investors Association and the All-Russia Research Institute for Materials and Technology Standardization.

  12. Miniature neutron sources: Thermal neutron sources and their users in the academic field

    International Nuclear Information System (INIS)

    Egelstaff, P.A.

    1992-01-01

    The three levels of thermal neutron sources are introduced - University laboratory sources infrastructure sources and world-class sources - and the needs for each kind and their inter-dependence will be emphasized. A description of the possibilities for University sources based on α-Be reactions or spontaneous fission emission is given, and current experience with them is described. A new generation of infrastructure sources is needed to continue the regional programs based on small reactors. Some possibilities for accelerator sources that could meet this need are considered

  13. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  14. Development of high time-resolution laser flash equipment for thermal diffusivity measurements using miniature-size specimens

    International Nuclear Information System (INIS)

    Shikama, Tatsuo; Namba, Chusei; Kosuda, Michinori; Maeda, Yukio.

    1994-01-01

    For measurements of thermal diffusivity of miniature-size specimens heavily irradiated by neutrons, a new Q-switched laser-flash instrument was developed. In the present instrument the time-resolution was improved to 0.1 ms by using a laser-pulse width of 25 ns. The realization of high time-resolution made it possible to measure the thermal diffusivity of thin specimens. It is expected that copper of 0.7 mm thick, and SUS 304 of 0.1 mm could be used for the measurements. In case of ATJ graphite, 0.5 mm thick specimen could be used for the reliable measurement in the temperature range of 300-1300 K. (author)

  15. Follow 1.1 - a program for visualization of Thermal-Hydraulic computer simulations. User's manual

    International Nuclear Information System (INIS)

    Hyvarinen, J.

    1990-04-01

    FOLLOW is a computer program designed to function as an analyst's aid when performing large thermalhydraulic and related safety calculations using the well known simulation codes RELAP5, MELCOR, SMABRE and TRAB. The code is a by-product of the effort to improve the analysis capabilities of the Finnish Centre for Radiation and Nuclear Safety (STUK). FOLLOW's most important application is as an on-line 'window' into the progress of the simulation calculation. The thermal-hydraulic analyses related to nuclear safety routinely require very long calculation times. FOLLOW provides a possibility to follow the course of the simulation and thus make observations of the results already during the simulation. FOLLOW's various outputs have been designed to mimic those available at nuclear power plant operators' console. Thus FOLLOW can also be used much like a nuclear power plant simulator. This manual describes the usages, features and input requirements of FOLLOW version 1.1, including a sample problem input and various outputs. (orig.)

  16. User Guide: How to Use and Operate Virtual Reality Equipment in the Systems Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations

    Science.gov (United States)

    2017-08-01

    Assessment and Usability Laboratory (SAUL) for Conducting Demonstrations by Michael N Geuss and Joseph A Campanelli Human Research and...Master unable to communicate with necessary computers .... 15 Fig. 14 PPT Studio N setup for 4 users...to communicate with each other and display the same virtual environment to multiple users. Cluster Master must be run on the computer running the

  17. Construction of TSL lector equipment with spectral resolution for the determination of thermally stimulated luminescence (TSL) properties of NaCl: Tl+ induced by UV-visible radiation

    International Nuclear Information System (INIS)

    Alvarez Romero, J.T.

    1993-01-01

    A revision of physical models of thermally stimulated luminescence (TSL) in crystals induced by both ionizing and non-ionizing radiation is presented. Particular emphasis is given to the connection of TSL with other thermally stimulated processes and physico-chemical phenomena because basic information on physical mechanics for TSL can be obtained through them. Glow curves of TSL induced by UV-visible radiation in NaCl: Tl + were measured. Additionally, the following spectrums were obtained for the same samples: optical absorption, excitation, fluorescent emission, and TSL emission. An optical absorption peak was correlated with the Thallium ion concentration. With respect to the TSL emission spectrums, some peaks associated to Thallium dimmers were at 298 and at 480 nm; others which were attributed to NaCl intrinsic properties were at 365, 430, 450 and 525 nm. Also TSL glow curves were studied as a function of the Thallium ion concentration (0.8 ppm to 14.8 ppm). They were de convoluted so as to calculate the activation energy, the frequency factor and the kinetic order for each separate TSL peak. Anomalous values were observed for some frequency factors. A method and TSL lector equipment to obtain TSL emission spectra were developed. (Author)

  18. Experimental and numerical study on thermal-hydraulic performance of wing-shaped-tubes-bundle equipped with winglet vortex generators

    Science.gov (United States)

    Abdelatief, Mohamed A.; Sayed Ahmed, Sayed Ahmed E.; Mesalhy, Osama M.

    2018-03-01

    The present work evaluates, experimentally and numerically, by the aid of commercial code FLUENT 6.3.26, the effects of relative locations (ΔX or ΔY), heights (hw), and span-angle (θ) of winglet-vortex-generators (WVGs) on thermal-hydraulic performance enhancement for down-stream and/or up-stream wing-shaped-tubes bundle heat exchangers for air Re ranging from 1.85 × 103 to 9.7 × 103 while water Re = 5 × 102. hw is set as 5 mm, 7.5 mm and 10 mm. For tube down-stream, θ is set as 0° (Base-line-case) and from 5° to 45° clockwise common-flow up (CFUp) and counterclockwise common-flow down (CFDn) while for tube up-stream it is set as -5°, -10° and -15° CFUp. Results show that the increase of θ counterclockwise-(CFDn) or clockwise-(CFUp) leads to increase the values of Nu number. Using WVGs with (+5 ° ≤ θ ≤ +45°) results in increasing Nu number by about from 34 to 48% comparing with that of base-line-case. The lowest values of drag coefficient ( f) for tube down-stream are obtained at +5° CFDn and -15° CFUp with respect to the base-line case. For tube up-stream, Nu number increases by increasing θ from 0° to -5° and the values of Nu number for θ varying from -5° to -15° have no significant changes. ( f) increases with hw and has negligible effect on ha. Furthermore, optimization analyses of θ and longitudinal fin (LF) are utilized, in four cases, for finding the optimum combination and maximum efficiency. The highest values of heat transfer parameters such as effectiveness (ɛ), area goodness factor (G) and efficiency index (η) and the lowest values of fluid-flow parameters like ( f) and hence the best efficiency, are achieved for -15° CFUp down-stream, ("case 3" of -15° CFUp down-stream and 6 mm LF height) and +5° CFDn down-stream. Correlations of Nu number, ( f) and (ɛ) as a function of θ and Re for the studied cases are performed.

  19. User Manual for XnWlup2.0, A Software to Visualize Nuclear Data for Thermal Reactors in WIMS-D Libraries

    International Nuclear Information System (INIS)

    Thiyagarajan, T.K.; Ganesan, S.; Jagannathan, V.; Karthikeyan, R.

    2002-10-01

    A project to prepare an exhaustive handbook of WIMS-D cross sections for thermal reactor applications comparing different WIMS-D compatible nuclear data libraries originating from various countries has been successfully implemented. A computer software, called XnWlup2.0, with graphical user interface for MS Windows has been developed at BARC. This report summarizes the salient features of this new software for the users of WIMS-D libraries. Several sample outputs produced by the software are presented to illustrate the powerful use of this software for routine use in reactor physics analyses. (author)

  20. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  1. Application of ASTEC, MELCOR, and MAAP Computer Codes for Thermal Hydraulic Analysis of a PWR Containment Equipped with the PCFV and PAR Systems

    Directory of Open Access Journals (Sweden)

    Siniša Šadek

    2017-01-01

    Full Text Available The integrity of the containment will be challenged during a severe accident due to pressurization caused by the accumulation of steam and other gases and possible ignition of hydrogen and carbon monoxide. Installation of a passive filtered venting system and passive autocatalytic recombiners allows control of the pressure, radioactive releases, and concentration of flammable gases. Thermal hydraulic analysis of the containment equipped with dedicated passive safety systems after a hypothetical station blackout event is performed for a two-loop pressurized water reactor NPP with three integral severe accident codes: ASTEC, MELCOR, and MAAP. MELCOR and MAAP are two major US codes for severe accident analyses, and the ASTEC code is the European code, joint property of Institut de Radioprotection et de Sûreté Nucléaire (IRSN, France and Gesellschaft für Anlagen und Reaktorsicherheit (GRS, Germany. Codes’ overall characteristics, physics models, and the analysis results are compared herein. Despite considerable differences between the codes’ modelling features, the general trends of the NPP behaviour are found to be similar, although discrepancies related to simulation of the processes in the containment cavity are also observed and discussed in the paper.

  2. Practical application of the benchmarking technique to increase reliability and efficiency of power installations and main heat-mechanic equipment of thermal power plants

    Science.gov (United States)

    Rimov, A. A.; Chukanova, T. I.; Trofimov, Yu. V.

    2016-12-01

    facilitating the analysis of the benchmarking results permitting to represent the quality loss of this power installation in the form of the difference between the actual value of the key indicator or comparison indicator and the best quartile of the existing distribution. The uncertainty of the obtained values of the quality loss indicators was evaluated by transforming the standard uncertainties of the input values into the expanded uncertainties of the output values with the confidence level of 95%. The efficiency of the technique is demonstrated in terms of benchmarking of the main thermal and mechanical equipment of the extraction power-generating units T-250 and power installations of the thermal power plants with the main steam pressure 130 atm.

  3. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  4. TASAC a computer program for thermal analysis of severe accident conditions. Version 3/01, Dec 1991. Model description and user`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Stempniewicz, M; Marks, P; Salwa, K

    1992-06-01

    TASAC (Thermal Analysis of Severe Accident Conditions) is computer code developed in the Institute of Atomic Energy written in FORTRAN 77 for the digital computer analysis of PWR rod bundle behaviour during severe accident conditions. The code has the ability to model an early stage of core degradation including heat transfer inside the rods, convective and radiative heat exchange as well as cladding interactions with coolant and fuel, hydrogen generation, melting, relocations and refreezing of fuel rod materials with dissolution of UO{sub 2} and ZrO{sub 2} in liquid phase. The code was applied for the simulation of International Standard Problem number 28, performed on PHEBUS test facility. This report contains the program physical models description, detailed description of input data requirements and results of code verification. The main directions for future TASAC code development are formulated. (author). 20 refs, 39 figs, 4 tabs.

  5. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Volume II. Program implementation

    International Nuclear Information System (INIS)

    1976-06-01

    A discussion is presented of the use of the RELAP4/MOD5 computer program in simulating the thermal-hydraulic behavior of light-water reactor systems when subjected to postulated transients such as a LOCA, pump failure, or nuclear excursion. The volume is divided into main sections which cover: (1) program description, (2) input data, (3) problem initialization, (4) user guidelines, (5) output discussion, (6) source program description, (7) implementation requirements, (8) data files, (9) description of PLOTR4M, (10) description of STH20, (11) summary flowchart, (12) sample problems, (13) problem definition, and (14) problem input

  6. TH-B-12A-01: TG124 “A Guide for Establishing a Credentialing and Privileging Program for Users of Fluoroscopic Equipment in Healthcare Organizations”

    Energy Technology Data Exchange (ETDEWEB)

    Moore, M [Philadelphia VA Medical Ctr., Philadelphia, PA (United States)

    2014-06-15

    Fluoroscopy credentialing and privileging programs are being instituted because of recorded patient injuries and the widespread growth in fluoroscopy use by operators whose medical education did not include formal fluoroscopy training. This lack of training is recognized as a patient safety deficiency, and medical physicists and health physicists are finding themselves responsible for helping to establish fluoroscopy credentialing programs. While physicians are very knowledgeable about clinical credentials review and the privileging process, medical physicists and health physicists are not as familiar with the process and associated requirements. To assist the qualified medical physicist (QMP) and the radiation safety officer (RSO) with these new responsibilities, TG 124 provides an overview of the credentialing process, guidance for policy development and incorporating trained fluoroscopy users into a facility's established process, as well as recommendations for developing and maintaining a risk-based fluoroscopy safety training program. This lecture will review the major topics addressed in TG124 and relate them to practical situations. Learning Objectives: Understand the difference between credentialing and privileging. Understand the responsibilities, interaction and coordination among key individuals and committees. Understand options for integrating the QMP and/or RSO and Radiation Safety Committee into the credentialing and privileging process. Understand issues related to implementing the fluoroscopy safety training recommendations and with verifying and documenting successful completion.

  7. TH-B-12A-01: TG124 “A Guide for Establishing a Credentialing and Privileging Program for Users of Fluoroscopic Equipment in Healthcare Organizations”

    International Nuclear Information System (INIS)

    Moore, M

    2014-01-01

    Fluoroscopy credentialing and privileging programs are being instituted because of recorded patient injuries and the widespread growth in fluoroscopy use by operators whose medical education did not include formal fluoroscopy training. This lack of training is recognized as a patient safety deficiency, and medical physicists and health physicists are finding themselves responsible for helping to establish fluoroscopy credentialing programs. While physicians are very knowledgeable about clinical credentials review and the privileging process, medical physicists and health physicists are not as familiar with the process and associated requirements. To assist the qualified medical physicist (QMP) and the radiation safety officer (RSO) with these new responsibilities, TG 124 provides an overview of the credentialing process, guidance for policy development and incorporating trained fluoroscopy users into a facility's established process, as well as recommendations for developing and maintaining a risk-based fluoroscopy safety training program. This lecture will review the major topics addressed in TG124 and relate them to practical situations. Learning Objectives: Understand the difference between credentialing and privileging. Understand the responsibilities, interaction and coordination among key individuals and committees. Understand options for integrating the QMP and/or RSO and Radiation Safety Committee into the credentialing and privileging process. Understand issues related to implementing the fluoroscopy safety training recommendations and with verifying and documenting successful completion

  8. Bevalac user's handbook

    International Nuclear Information System (INIS)

    1990-04-01

    This report is a users manual on the Bevalac accelerator facility. This paper discuses: general information; the Bevalac and its operation; major facilities and experimental areas; and experimental equipment

  9. User's manual for DELSOL2: a computer code for calculating the optical performance and optimal system design for solar-thermal central-receiver plants

    Energy Technology Data Exchange (ETDEWEB)

    Dellin, T.A.; Fish, M.J.; Yang, C.L.

    1981-08-01

    DELSOL2 is a revised and substantially extended version of the DELSOL computer program for calculating collector field performance and layout, and optimal system design for solar thermal central receiver plants. The code consists of a detailed model of the optical performance, a simpler model of the non-optical performance, an algorithm for field layout, and a searching algorithm to find the best system design. The latter two features are coupled to a cost model of central receiver components and an economic model for calculating energy costs. The code can handle flat, focused and/or canted heliostats, and external cylindrical, multi-aperture cavity, and flat plate receivers. The program optimizes the tower height, receiver size, field layout, heliostat spacings, and tower position at user specified power levels subject to flux limits on the receiver and land constraints for field layout. The advantages of speed and accuracy characteristic of Version I are maintained in DELSOL2.

  10. COMMIX-1A: a three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems. Volume I: users manual

    International Nuclear Information System (INIS)

    Domanus, H.M.; Schmitt, R.C.; Sha, W.T.; Shah, V.L.

    1983-12-01

    The COMMIX-1A computer program is an updated and improved version of COMMIX-1 designed to analyze steady-state/transient, single-phase, three-dimensional fluid flow with heat transfer in reactor components and multicomponent systems. A new porous-media formulation via local volume averaging has been derived and employed in the COMMIX code. The concepts of volume porosity, directional surface permeability, distributed resistance, and distributed heat source or sink is used in the new porous-media formulation to model a flow domain with stationary structures. The concept of directional surface permeability is new and greatly facilitates modeling of velocity and temperature fields in anisotropic media. The new porous-media formulation represents the first unified approach to thermal-hydraulic analysis. It is now possible to perform a multidimensional thermal-hydraulic simulation of either a single component, such as a rod bundle, reactor plenum, piping system, heat exchanger, etc., or a multicomponent system that is a combination of these components. The conservation equations of mass, momentum, and energy based on the new porous-media formulation are solved as a boundary-value problem in space and an initial-value problem in time. Two other unique features provided in the COMMIX-1A code are (1) two solution procedures - a semi-implicit procedure modified from ICE and a fully-implicit procedure, named SIMPLEST-ANL, similar to the SIMPLE/SIMPLER algorithms - available a user's option and (2) a geometrical package capable of approximating many geometries. This report (Volume I) describes in detail the basic equations, formulations, solution procedures, flow charts, rebalancing scheme for faster convergence, options available to users, models to describe the auxiliary phenomena, input instructions, and two sample problems. The Volume II assembles and summarizes the results of many simulations that have been performed with COMMIX-1A computer program

  11. Fission product data for thermal reactors. Final report. Part 2. Users manual for EPRI-CINDER code and data

    International Nuclear Information System (INIS)

    England, T.R.; Wilson, W.B.; Stamatelatos, M.G.

    1976-12-01

    A four-group fission-product absorption chain library using ENDF/B-IV decay data and cross sections processed with a typical light water reactor spectrum for a modified version of the original CINDER code has been developed as described in Part 1. CINDER is a general point-depletion and fission product code based on an analytical solution of the equations describing nuclides coupled in any linear sequence of radioactive decays and neutron absorptions. The basic code has been in wide use for a number of years. Previously, the user was required to specify all physical data. This report describes the chain library in detail and a modified version of the basic CINDER code (EPRI-CINDER) that is still compatible with existing libraries

  12. Sample-related peripheral equipment at IPNS

    International Nuclear Information System (INIS)

    Bohringer, D.E.; Crawford, R.K.

    1985-01-01

    This paper describes samples environment equipment provided by IPNS to visiting users and staff scientists. Of the twelve horizontal neutron beam stations, (ten now operational, two under construction) all use one or more form of such support equipment. An in-house support group devotes a significant fraction of its time to development, calibration, and maintenance of this equipment

  13. Control and diagnostics of technical state of main electro technical and thermal equipment of NPP, TPS and HPS on the basis of thermovision technologies

    International Nuclear Information System (INIS)

    Banduryan, B.B.; Fedorenko, G.M.; Ostapchuk, L.B.; Saratov, V.O.

    2006-01-01

    The opportunity of using of thermovision technologies for detection of defects NPP, TPS and HPS electro technical and power equipment is shown. The results of thermovision monitoring of a turbine generator stator technical state are represented. The method for thermovision control of a technical state of a electrical machines and apparatus construction elements, for which the patent of Ukraine have been obtained, is described. he verification of the offered expedient thermovision control and diagnostics at 'Elektrovazhmash' factory was carried out

  14. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  15. Thermal separation method of preparing apyrogenic and sterile sup(99m)Tc2O7 and equipment for this method

    International Nuclear Information System (INIS)

    Machan, V.; Rusek, V.; Vlcek, J.; Kokta, L.; Smejkal, Z.; Rohacek, J.

    1978-01-01

    Pure apyrogenic and sterile sup(99m)Tc 2 O 7 is prepared from a mixture of technetium and molybdenum or their compounds, e.g., MoO 3 and Tc 2 O 7 . The mixture is mixed with a granular low-melting material and during separation is heated to 650 to 1000 degC for a time necessary for Tc 2 O 7 liberation. While cooling to room temperature Tc 2 O 7 is condensed outside the molybdenum region. The separation equipment consists of an outer tube with a ground surface extending into the heating system, a removable vessel, a replaceable cartridge for storing the mother nuclide, and a bacteriological filter. (H.S.)

  16. Nuclear fast neutron reactor cooled by a liquid metal and of which internal structures are equipped with a thermal protection device

    International Nuclear Information System (INIS)

    Lemercier, G.; Lions, N.

    1986-01-01

    The internal structures of a nuclear fast neutron reactor are covered at least partially, on the most hot side, by a thermal protection device. This device comprises modular plates arranged end to end with a certain play between themselves and taking approximately the shape of the internal structures. Each plate is fixed in its center on the internal structures by a stud. A small plate fixed at one of the corners of each plate and covering partially the adjacent plates ensures the safety fixing of these ones [fr

  17. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  18. Personal protective equipment

    International Nuclear Information System (INIS)

    2004-01-01

    This Practical Radiation Technical Manual is one of a series that has been designed to provide guidance on radiological protection for employers, radiation protection officers, managers and other technically competent persons who have responsibility for ensuring the safety of employees working with ionizing radiation. The Manual may be used with the appropriate IAEA Practical Radiation Safety Manuals to provide training, instruction and information for all employees engaged in work with ionizing radiation. Personal protective equipment (PPE) includes clothing or other special equipment that is issued to individual workers to provide protection against actual or potential exposure to ionizing radiations. It is used to protect each worker against the prevailing risk of external or internal exposure in circumstances in which it is not reasonably practicable to provide complete protection by means of engineering controls or administrative methods. Adequate personal protection depends on PPE being correctly selected, fitted and maintained. Appropriate training for the users and arrangements to monitor usage are also necessary to ensure that PPE provides the intended degree of protection effectively. This Manual explains the principal types of PPE, including protective clothing and respiratory protective equipment (RPE). Examples of working procedures are also described to indicate how PPE should be used within a safe system of work. The Manual will be of most benefit if it forms part of a more comprehensive training programme or is supplemented by the advice of a qualified expert in radiation protection. Some of the RPE described in this Manual should be used under the guidance of a qualified expert

  19. Information for stores users

    CERN Multimedia

    Logistics Group - FI Department

    2005-01-01

    The Farnell catalogue can now be accessed from the Material Request form on EDH in addition to the CERN Stores catalogue. Users can order Farnell equipment as well as standard Stores equipment at the same time using a single document, the EDH Materials Request form. The Materials Request form offers users items from both the internal 'Stores' catalogue and the external 'Farnell' catalogue, all of which may be ordered on the same form. The system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Farnell equipment to Farnell. The delivery time is 48 hours in both cases. Requests for materials are routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  20. Equipment to evaluate in experimental form the thermal conductivity of the construction materials; Equipo para evaluar en forma experimental el coeficiente de conductividad termica de los materiales de construccion

    Energy Technology Data Exchange (ETDEWEB)

    Lopez C, Raymundo; Morales G, Juan R.; Diaz C, Alen; Lizardi R, Arturo [Universidad Autonoma Metropolitana-Azcapotzalco, Mexico, D. F. (Mexico); Vaca M, Mabel [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-04-01

    An equipment meant to obtain the thermal conductivity coefficient was designed, constructed and evaluated. Convection losses in the experimental device were reduced by means of a vacuum chamber that wraps it. Conduction losses were minimized with the proper insulation. The tested materials are the most frequently used in the construction of buildings in Mexico, such as concrete, burnt brick, adobe and gypsum. Results observed are comparable to those reported in the literature. The essays done using the vacuum chamber produced values of thermal conductivity coefficient 3% lower than those obtained without using it. [Spanish] Se diseno, construyo y evaluo un equipo, con el cual se obtiene el coeficiente de conductividad termica en diversos materiales. En este se reducen las perdidas por conveccion, colocando una camara de vacio alrededor del conjunto de prueba. Las perdidas por conduccion se minimizan con un aislamiento adecuado. Los materiales evaluados son los que mas se utilizan en la construccion en Mexico, a saber, el concreto, el ladrillo cocido, el adobe y el yeso. Los valores obtenidos, sin considerar las perdidas por conveccion, se comparan con los de la literatura. Los ensayos utilizando la camara de vacio proporcionan valores del coeficiente de conductividad termica menores en 3% a los obtenidos sin dicha camara.

  1. Origins of eponymous orthopaedic equipment.

    Science.gov (United States)

    Meals, Clifton; Wang, Jeffrey

    2010-06-01

    Orthopaedists make great use of eponymous equipment, however the origins of these tools are unknown to many users. This history enriches, enlightens, and enhances surgical education, and may inspire modern innovation. We explored the origins of common and eponymous orthopaedic equipment. We selected pieces of equipment named for their inventors and in the broadest use by modern orthopaedists. We do not describe specialized orthopaedic implants and instruments owing to the overwhelming number of these devices. The history of this equipment reflects the coevolution of orthopaedics and battlefield medicine. Additionally, these stories evidence the primacy of elegant design and suggest that innovation is often a process of revision and refinement rather than sudden inspiration. Their history exposes surgical innovators as brilliant, lucky, hardworking, and sometimes odd. These stories amuse, enlighten, and may inspire modern orthopaedists to develop creative solutions of their own. The rich history of the field's eponymous instruments informs an ongoing tradition of innovation in orthopaedics.

  2. Usuários de drogas injetáveis e terapia anti-retroviral: percepções das equipes de farmácia Injecting drug users and antiretroviral therapy: perceptions of pharmacy teams

    Directory of Open Access Journals (Sweden)

    Chizuru Minami Yokaichiya

    2007-12-01

    Full Text Available OBJETIVO: Compreender as percepções das equipes de farmácia sobre seu papel nos desafios assistenciais e adesão aos anti-retrovirais de usuários de drogas injetáveis vivendo com HIV/Aids. MÉTODOS: Estudo qualitativo por grupos focais e análise temática das falas produzidas com farmacêuticos, técnicos e auxiliares com experiência superior a seis meses na dispensação de medicamentos, de 15 unidades assistenciais de DST/Aids do município de São Paulo, em 2002. RESULTADOS: Formaram-se três grupos, totalizando 29 participantes, provenientes de 12 dos 15 serviços existentes, com 12 universitários e 17 profissionais de nível médio. Os grupos concluíram que a farmácia tem importante papel na dispensação de anti-retrovirais, o que se reflete na adesão ao tratamento, pois por meio de seus procedimentos podem ser construídas relações de confiança. Avaliam, porém, que tal construção não ocorra pela excessiva burocratização de suas atividades. Isso repercute negativamente para todos os pacientes, em especial sobre usuários de drogas injetáveis, concebidos como "pessoas difíceis". Tal concepção essencializa seus comportamentos: seriam confusos, com limites de compreensão e sem possibilidades de adesão ao tratamento. Os profissionais, porém, afirmam que tratam esses pacientes tal como os demais, igualando-os. Não percebem neste proceder, uma invisibilização das necessidades específicas dos usuários de drogas injetáveis no serviço, bem como a possibilidade de gerarem estereótipos estigmatizantes com barreira adicional ao trabalho da adesão. CONCLUSÕES: Embora a farmácia seja indicada como espaço potencialmente favorável para escuta e construção de vínculos com os usuários, os resultados mostram obstáculos objetivos e subjetivos para torná-la propícia para trabalhar a adesão.OBJECTIVE: To understand the perceptions of pharmacy teams about their role in the healthcare assistance challenges and

  3. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  4. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  5. Information for stores users

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  6. INFORMATION FOR STORES USERS

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  7. Information for stores users

    CERN Multimedia

    2006-01-01

    The Radiospares Catalogue is now accessible from the Material Request page on EDH in the same way as the CERN Stores Catalogue. This means that users can order Radiospares equipment by completing an EDH Materials Request form. N.B.: The system will automatically forward orders for standard Stores equipment to the CERN Stores and those for Radiospares equipment to Radiospares. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  8. Information for Stores users

    CERN Multimedia

    FI Department

    2008-01-01

    The DISTRELEC catalogue (IT) is now available in EDH in addition to the CERN Stores catalogue and the catalogues of existing suppliers. Using an EDH materials request form, users can now order DISTRELEC equipment from amongst the following product groups: peripherals, multimedia, PC components, data media, communication and data cables and adapters. Non-authorised materials will be clearly indicated. As a reminder, the system automatically manages the distribution of standard Stores equipment and punch out equipment ordered on the same request form. In both cases, delivery will take a maximum of 48 hours. The approval of the EDH document will follow the usual EDH routing procedures. Logistics Group FI Department

  9. Test and User Facilities | NREL

    Science.gov (United States)

    Test and User Facilities Test and User Facilities Our test and user facilities are available to | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z B Battery Thermal and Life Test Facility Biochemical Conversion Pilot Plant C Controllable Grid Interface Test System D Dynamometer Test Facilities

  10. Maintaining semen quality by improving cold chain equipment used in cattle artificial insemination.

    Science.gov (United States)

    Lieberman, Daniel; McClure, Elizabeth; Harston, Stephen; Madan, Damian

    2016-06-17

    Artificial insemination of dairy cattle is a common practice in the developing world that can improve farmer incomes and food security. Maintaining the fertilizing potential of frozen semen as it is manipulated, transported and stored is crucial to the success of this process. Here we describe simple technological improvements to protect semen from inadvertent thermal fluctuations that occur when users mishandle semen using standard equipment. We show that when frozen semen is mishandled, characteristics of semen biology associated with fertility are negatively affected. We describe several design modifications and results from thermal performance tests of several improved prototypes. Finally, we compare semen that has been mishandled in standard and improved equipment. The data suggest that our canister improvements can better maintain characteristics of semen biology that correlate with fertility when it is mishandled.

  11. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  12. Failure diagnosis aiding device for plant equipment

    International Nuclear Information System (INIS)

    Uhara, Yoshihiko.

    1990-01-01

    The present invention intends to improve the efficiency of trouble shooting for equipments of industrial plants such as nuclear power plants. The device of the present invention comprises an intelligence base and an inference mechanism base. The intelligence base comprises a rule base, an information storing section having a part frame and a working frame and a user's frame. The parts frame contains the failure rate on every parts and data on related operations. The working frame contains the importance and frequency of working. The user's frame contains parameters showing the extent of user's skills. The rule base, the parts frame and the working frame can be selected in accordance with the extent of the user's skill in the inference mechanism. With such a constitution, failures can be checked with the intelligence base in accordance with the knowledges for the failures of the equipments and the extent of user's skill by way of the inference mechanism. (I.S.)

  13. Acquired experience on organizing 3D S.UN.COP: international course to support nuclear license by user training in the areas of scaling, uncertainty, and 3D thermal-hydraulics/neutron-kinetics coupled codes

    Energy Technology Data Exchange (ETDEWEB)

    Petruzzi, Alessandro; D' Auria, Francesco [University of Pisa, San Piero a Grado (Italy). Nuclear Research Group San Piero a Grado (GRNSPG); Galetti, Regina, E-mail: regina@cnen.gov.b [National Commission for Nuclear Energy (CNEN), Rio de Janeiro, RJ (Brazil); Bajs, Tomislav [University of Zagreb (Croatia). Fac. of Electrical Engineering and Computing. Dept. of Power Systems; Reventos, Francesc [Technical University of Catalonia, Barcelona (Spain). Dept. of Physics and Nuclear Engineering

    2011-07-01

    Thermal-hydraulic system computer codes are extensively used worldwide for analysis of nuclear facilities by utilities, regulatory bodies, nuclear power plant designers, vendors, and research organizations. Computer code user represents a source of uncertainty that may significantly affect the results of system code calculations. Code user training and qualification represent an effective means for reducing the variation of results caused by the application of the codes by different users. This paper describes the experience in applying a systematic approach to training code users who, upon completion of the training, should be able to perform calculations making the best possible use of the capabilities of best estimate codes. In addition, this paper presents the organization and the main features of the 3D S.UN.COP (scaling, uncertainty, and 3D coupled code calculations) seminars during which particular emphasis is given to practical applications in connection with the licensing process of best estimate plus uncertainty methodologies, showing the designer, utility and regulatory approaches. (author)

  14. Acquired experience on organizing 3D S.UN.COP: international course to support nuclear license by user training in the areas of scaling, uncertainty, and 3D thermal-hydraulics/neutron-kinetics coupled codes

    International Nuclear Information System (INIS)

    Petruzzi, Alessandro; D'Auria, Francesco; Galetti, Regina; Bajs, Tomislav; Reventos, Francesc

    2011-01-01

    Thermal-hydraulic system computer codes are extensively used worldwide for analysis of nuclear facilities by utilities, regulatory bodies, nuclear power plant designers, vendors, and research organizations. Computer code user represents a source of uncertainty that may significantly affect the results of system code calculations. Code user training and qualification represent an effective means for reducing the variation of results caused by the application of the codes by different users. This paper describes the experience in applying a systematic approach to training code users who, upon completion of the training, should be able to perform calculations making the best possible use of the capabilities of best estimate codes. In addition, this paper presents the organization and the main features of the 3D S.UN.COP (scaling, uncertainty, and 3D coupled code calculations) seminars during which particular emphasis is given to practical applications in connection with the licensing process of best estimate plus uncertainty methodologies, showing the designer, utility and regulatory approaches. (author)

  15. TRAC User's Guide

    International Nuclear Information System (INIS)

    Boyack, B.E.; Stumpf, H.; Lime, J.F.

    1985-11-01

    This guide has been prepared to assist users in applying the Transient Reactor Analysis Code (TRAC). TRAC is an advanced best-estimate systems code for analyzing transients in thermal-hydraulic systems. The code is very general. Because it is general, efforts to model specific nuclear power plants or experimental facilities often present a challenge to the TRAC user. This guide has been written to assist first-time or intermediate users. It is specifically written for the TRAC version designated TRAC-PF1/MOD1. The TRAC User's Guide should be considered a companion document to the TRAC Code Manual; the user will need both documents to use TRAC effectively. 18 refs., 45 figs., 19 tabs

  16. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  17. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Volume II. Program implementation

    International Nuclear Information System (INIS)

    1976-09-01

    This portion of the RELAP4/MOD5 User's Manual presents the details of setting up and entering the reactor model to be evaluated. The input card format and arrangement is presented in depth, including not only cards for data but also those for editing and restarting. Problem initalization including pressure distribution and energy balance is discussed. A section entitled ''User Guidelines'' is included to provide modeling recommendations, analysis and verification techniques, and computational difficulty resolution. The section is concluded with a discussion of the computer output form and format

  18. CANAL user's manual

    International Nuclear Information System (INIS)

    Faya, A.; Wolf, L.; Todreas, N.

    1979-11-01

    CANAL is a subchannel computer program for the steady-state and transient thermal hydraulic analysis of BWR fuel rod bundles. The purpose of this manual is to introduce the user into the mechanism of running the code by providing information about the input data and options

  19. Protecting electrical equipment against dust explosions

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, J

    1981-07-01

    The new ordinance on electrical equipment in hazardous areas and the new VDE 0165/6.80 have brought about significant changes in the field of electrical equipment in areas with a explosion hazard due inflammable dust. There are no constructional regulations yet in this field, and producers, planners, and users are uncertain about what measures to take. The article attempts to clear up a few points.

  20. User's inspection authorities in France

    International Nuclear Information System (INIS)

    Robault, B.; Paquet, D.

    2004-01-01

    The article 14 of the directive 97/23 EC concerning pressure equipment has been introduced in french regulation. Electricite de France (EDF) and Gaz de France (GDF) decided to become user inspectorates. The EDF user inspectorate was authorized by the departmental order of 10/10/2000 re-conducted by departmental order of 19/12/2002. The GDF user inspectorate was authorized by the departmental order of 10/07/2002 re-conducted by departmental order of 09/02/2004. The presentation of user inspectorates evaluation methods associated with the experience of firsts evaluations shows the interest of user inspectorates. This interest concerned specific equipments with experience accumulated in manufacturing and plant working. (authors)

  1. Connected Equipment Maturity Model Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Butzbaugh, Joshua B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mayhorn, Ebony T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sullivan, Greg [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Whalen, Scott A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-01

    The Connected Equipment Maturity Model (CEMM) evaluates the high-level functionality and characteristics that enable equipment to provide the four categories of energy-related services through communication with other entities (e.g., equipment, third parties, utilities, and users). The CEMM will help the U.S. Department of Energy, industry, energy efficiency organizations, and research institutions benchmark the current state of connected equipment and identify capabilities that may be attained to reach a more advanced, future state.

  2. [Development of Hospital Equipment Maintenance Information System].

    Science.gov (United States)

    Zhou, Zhixin

    2015-11-01

    Hospital equipment maintenance information system plays an important role in improving medical treatment quality and efficiency. By requirement analysis of hospital equipment maintenance, the system function diagram is drawed. According to analysis of input and output data, tables and reports in connection with equipment maintenance process, relationships between entity and attribute is found out, and E-R diagram is drawed and relational database table is established. Software development should meet actual process requirement of maintenance and have a friendly user interface and flexible operation. The software can analyze failure cause by statistical analysis.

  3. Ensuring sustained user quality in buildings. Success contracting with functional tendering of the building services equipment guarantees quality for 15 years; Nutzerqualitaet in Gebaeuden dauerhaft sicherstellen. Erfolgscontracting mit funktionaler Ausschreibung ermoeglicht eine 15-jaehrige Garantie auf die Gebaeudetechnik

    Energy Technology Data Exchange (ETDEWEB)

    Milles, Uwe

    2012-07-01

    Until now, buildings regularly require more energy and provide less user quality in practice than was to be expected from the installed technology during the planning. That has structural reasons. The naerco research project has investigated this aspect and developed the success contracting concept: pre-defined energy and quality parameters are contracted out as part of a function-based tender. A contractor guarantees their realisation for 15 years. The contractual process also includes continual control of the agreed values and a bonus-malus system.

  4. Requirements for industrial x-ray equipment

    International Nuclear Information System (INIS)

    1987-01-01

    This safety code is concerned with the protection of all individuals who may be exposed to radiation emitted by X-ray equipment operating at energies up to 1 MeV as used in industrial radiography. This code presents basic radiation safety information for the protection of personnel operating and servicing X-ray equipment and other workers and the general public in the vicinity of areas where X-ray equipment is in operation. It specifies general safety features of design, construction and functioning of X-ray equipment and facilities; describes the responsibilities of the user, operator and maintenance personnel; contains recommendations to ensure that the X-ray equipment is used and maintained in accordance with the ALARA principle; and describes a program of personnel monitoring and radiation safety surveys. ( 6 refs., 5 tabs., 4 figs.)

  5. A simplified model to study the location impact of latent thermal energy storage in building cooling heating and power system

    International Nuclear Information System (INIS)

    Zhang, Yin; Wang, Xin; Zhang, Yinping; Zhuo, Siwen

    2016-01-01

    Introducing the thermal energy storage (TES) equipment into the building cooling heating and power (BCHP) system proves to be an effective way to improve the part load performance of the whole system and save the primary energy consumption. The location of TES in BCHP has a great impact on the thermal performance of the whole system. In this paper, a simplified model of TES-BCHP system composed of a gas turbine, an absorption chiller/an absorption heat pump, and TES equipment with phase change materials (PCM) is presented. In order to minimize the primary energy consumption, the performances of BCHP systems with different PCM-TES locations (upstream and downstream) are analyzed and compared, for a typical hotel and an office building respectively. Moreover, the influence of the thermal performance of PCM-TES equipment on the energy saving effect of the whole system is investigated. The results confirm that PCM-TES can improve the energy efficiency and reduce the installed capacities of energy supply equipment, and that the optimal TES location in BCHP highly depends on the thermal performance of the TES equipment and the user load characteristics. It also indicates that: 1) the primary energy saving ratio of PCM-TES-BCHP increases with increasing NTU of TES; 2) for the studied cases, downstream TES location becomes more preferable when user loads fluctuate greatly; 3) only downstream TES can reduce the installed capacities of absorption chiller/absorption heat pump. This work can provide guidance for PCM-TES-BCHP system design. - Highlights: • A simplified model of the PCM-TES-BCHP system is established. • TES can increase energy efficiency and decrease installed capacity of equipment. • Primary energy saving ratio increases with increasing NTU of TES. • Downstream TES location is more preferable when user loads fluctuate greatly. • Optimal TES location depends on equipment performances and load characteristics.

  6. Information for stores users

    CERN Multimedia

    2006-01-01

    The Bossard catalogue is now accessible alongside the CERN Stores catalogue from the Material Request form on EDH. Users will thus be able to order Bossard equipment using the EDH Materials Request form. As a reminder, the system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Bossard equipment to Bossard. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Some items will remain available from the emergency desk in the event of urgent requests. These items will be visible in the Stores catalogue even if they cannot be purchased via the EDH material request form. Logistics Group FI Department

  7. Truck shovel users group

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J. [Surface Mining Association for Research and Technology, AB (Canada)

    2008-07-01

    The Truck Shovel Users Group (TSUG) was developed as part of the Surface Mining Association for Research and Technology (SMART), an association of companies that meet to coordinate technology developments for the mining industry. The TSUG meet regularly to discuss equipment upgrades, maintenance planning systems, and repair techniques. The group strives to maximize the value of its assets through increased safety, equipment performance and productivity. This presentation provided administrative details about the TSUG including contact details and admission costs. It was concluded that members of the group must be employed by companies that use heavy mining equipment, and must also be willing to host meetings, make presentations, and support the common goals of the group. tabs., figs.

  8. Making petroleum equipment safe, a priority

    International Nuclear Information System (INIS)

    1999-01-01

    Changes to the 'Act respecting the use of petroleum products' have been announced effective May 1, 1999. The changes have been made to reduce problems which can be attributed to petroleum product leaks. The new regulations will make owners and users of petroleum equipment, including underground and above-ground storage equipment and commercial storage tanks, more accountable for the use of their own equipment. The emphasis in the new regulations is based upon the storage capacity of petroleum equipment and the risks associated with this equipment, rather than the on the activities of the owners concerned. Accordingly, the new regulations call for stricter requirements for high-risk equipment, a private equipment inspection plan, a two-year operating permit, replacing the current permits and certificates, a tariff structure based on the risks associated with the equipment, and deregulation of commercial activities involving petroleum products that require no equipment. Additionally, the amendments to the Act transfer responsibility for administration to the Regie du batiment and to the Ministere des Transports. Details of each of these changes are explained

  9. Shipboard and laboratory equipment

    Digital Repository Service at National Institute of Oceanography (India)

    Shyamprasad, M.; Ramaswamy, V.

    The polymetallic nodules occur at an average depth of 4500 m. Adequate equipment and techniques are required for the exploration at such depths. Shipboard and various laboratory equipments for the sampling of polymetallic nodules is described...

  10. Remote handling equipment

    International Nuclear Information System (INIS)

    Clement, G.

    1984-01-01

    After a definition of intervention, problems encountered for working in an adverse environment are briefly analyzed for development of various remote handling equipments. Some examples of existing equipments are given [fr

  11. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  12. BP volume reduction equipment

    International Nuclear Information System (INIS)

    Kitamura, Yoshinori; Muroo, Yoji; Hamanaka, Isao

    2003-01-01

    A new type of burnable poison (BP) volume reduction system is currently being developed. Many BP rods, a subcomponent of spent fuel assemblies are discharged from nuclear power reactors. This new system reduces the overall volume of BP rods. The main system consists of BP rod cutting equipment, equipment for the recovery of BP cut pieces, and special transport equipment for the cut rods. The equipment is all operated by hydraulic press cylinders in water to reduce operator exposure to radioactivity. (author)

  13. 21 CFR 1020.32 - Fluoroscopic equipment.

    Science.gov (United States)

    2010-04-01

    ... manufacturer shall provide to users, under § 1020.30(h)(1)(i), precautions concerning the importance of remote... specified in § 1020.32(d)(1)(v). (iii) Equipment provided with both an AERC mode and a manual mode shall not... shall be operable only when continuous manual activation is provided by the operator. A continuous...

  14. The influence of thermal comfort and user control on the design of a passive solar school building-Locksheath Primary School

    Energy Technology Data Exchange (ETDEWEB)

    Baker, N

    1982-12-01

    This article describes the design of a Primary School at Locksheath, Hampshire, England. The design is the result of collaboration between the Hampshire County Council's Architect's Department and the Martin Centre for Architectural and Urban Studies, University of Cambridge. The design has been strongly influenced by considerations of energy conservation, maximum use of solar energy, and thermal comfort. Stress is placed on the role of the occupant in the control of the building. Predictive analysis indicates that the large conservatory incorporated makes a considerable reduction in heating energy demand.

  15. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  16. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  17. Equipment installation structure of roof slab for tank type FBR and method of equipment installation

    International Nuclear Information System (INIS)

    Sakai, Takao; Yamakawa, Masanori; Otsuka, Masaya; Sekine, Katsuhisa

    1986-01-01

    Purpose: To reduce equipment thermal stress and deformation by eliminating uneven temperature distribution caused at the equipment through section of the roof slab for the tank FBR, and at the same time, simplify the structure installation. Method: Multiple number of vertical fin projects are fit on the equipment through-section inside wall for the roof slab and the cylindrical equipment peripheral wall, and with these projected fins, the ring space of the through section is vertically divided into multiple sections in the circumferential direction. The vertical fins on the through-section inside wall and the fins on the equipment peripheral wall are contacted with each other by revolving them in the lateral direction. As a result, the natural convection caused by the difference of temperatures in the vertical direction of the ring space becomes a convection within each sector divided, and never generates circumferential circulation, which reduce uneven temperature distribution caused at the equipment through section. (Kawakami, Y.)

  18. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  19. TASAC a computer program for thermal analysis of severe accident conditions. Version 3/01, Dec 1991. Model description and user's guide

    International Nuclear Information System (INIS)

    Stempniewicz, M.; Marks, P.; Salwa, K.

    1992-06-01

    TASAC (Thermal Analysis of Severe Accident Conditions) is computer code developed in the Institute of Atomic Energy written in FORTRAN 77 for the digital computer analysis of PWR rod bundle behaviour during severe accident conditions. The code has the ability to model an early stage of core degradation including heat transfer inside the rods, convective and radiative heat exchange as well as cladding interactions with coolant and fuel, hydrogen generation, melting, relocations and refreezing of fuel rod materials with dissolution of UO 2 and ZrO 2 in liquid phase. The code was applied for the simulation of International Standard Problem number 28, performed on PHEBUS test facility. This report contains the program physical models description, detailed description of input data requirements and results of code verification. The main directions for future TASAC code development are formulated. (author). 20 refs, 39 figs, 4 tabs

  20. IAC user manual

    Science.gov (United States)

    Vos, R. G.; Beste, D. L.; Gregg, J.

    1984-01-01

    The User Manual for the Integrated Analysis Capability (IAC) Level 1 system is presented. The IAC system currently supports the thermal, structures, controls and system dynamics technologies, and its development is influenced by the requirements for design/analysis of large space systems. The system has many features which make it applicable to general problems in engineering, and to management of data and software. Information includes basic IAC operation, executive commands, modules, solution paths, data organization and storage, IAC utilities, and module implementation.

  1. Bevalac user's handbook

    Energy Technology Data Exchange (ETDEWEB)

    1990-04-01

    This report is a users manual on the Bevalac accelerator facility. This paper discuses: general information; the Bevalac and its operation; major facilities and experimental areas; and experimental equipment.

  2. HyRAM V1.0 User Guide

    Energy Technology Data Exchange (ETDEWEB)

    Groth, Katrina M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zumwalt, Hannah Ruth [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Clark, Andrew Jordan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-03-01

    Hydrogen Risk Assessment Models (HyRAM) is a prototype software toolkit that integrates data and methods relevant to assessing the safety of hydrogen fueling and storage infrastructure. The HyRAM toolkit integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing the impact of hydrogen hazards, including thermal effects from jet fires and thermal pressure effects from deflagration. HyRAM version 1.0 incorporates generic probabilities for equipment failures for nine types of components, and probabilistic models for the impact of heat flux on humans and structures, with computationally and experimentally validated models of various aspects of gaseous hydrogen release and flame physics. This document provides an example of how to use HyRAM to conduct analysis of a fueling facility. This document will guide users through the software and how to enter and edit certain inputs that are specific to the user-defined facility. Description of the methodology and models contained in HyRAM is provided in [1]. This User’s Guide is intended to capture the main features of HyRAM version 1.0 (any HyRAM version numbered as 1.0.X.XXX). This user guide was created with HyRAM 1.0.1.798. Due to ongoing software development activities, newer versions of HyRAM may have differences from this guide.

  3. RETRIEVAL EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    J. Steinhoff

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) retrieval from the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. There are no quality assurance requirements or QA controls in this document. Retrieval under normal conditions is accomplished with the same fleet of equipment as is used for emplacement. Descriptions of equipment used for retrieval under normal conditions is found in Emplacement Equipment Descriptions, DI: BCAF00000-01717-5705-00002 (a document in progress). Equipment used for retrieval under abnormal conditions is addressed in this document and consists of the following: (1) Inclined Plane Hauler; (2) Bottom Lift Transporter; (3) Load Haul Dump (LHD) Loader; (4) Heavy Duty Forklift for Emplacement Drifts; (5) Covered Shuttle Car; (6) Multipurpose Vehicle; and (7) Scaler

  4. GRSAC Users Manual

    International Nuclear Information System (INIS)

    Ball, S.J.; Nypaver, D.J.

    1999-01-01

    An interactive workstation-based simulation code (GRSAC) for studying postulated severe accidents in gas-cooled reactors has been developed to accommodate user-generated input with ''smart front-end'' checking. Code features includes on- and off-line plotting, on-line help and documentation, and an automated sensitivity study option. The code and its predecessors have been validated using comparisons with a variety of experimental data and similar codes. GRSAC model features include a three-dimensional representation of the core thermal hydraulics, and optional ATWS (anticipated transients without scram) capabilities. The user manual includes a detailed description of the code features, and includes four case studies which guide the user through four different examples of the major uses of GRSAC: an accident case; an initial conditions setup and run; a sensitivity study; and the setup of a new reactor model

  5. GRSAC Users Manual

    Energy Technology Data Exchange (ETDEWEB)

    Ball, S.J.; Nypaver, D.J.

    1999-02-01

    An interactive workstation-based simulation code (GRSAC) for studying postulated severe accidents in gas-cooled reactors has been developed to accommodate user-generated input with ''smart front-end'' checking. Code features includes on- and off-line plotting, on-line help and documentation, and an automated sensitivity study option. The code and its predecessors have been validated using comparisons with a variety of experimental data and similar codes. GRSAC model features include a three-dimensional representation of the core thermal hydraulics, and optional ATWS (anticipated transients without scram) capabilities. The user manual includes a detailed description of the code features, and includes four case studies which guide the user through four different examples of the major uses of GRSAC: an accident case; an initial conditions setup and run; a sensitivity study; and the setup of a new reactor model.

  6. Understanding users

    DEFF Research Database (Denmark)

    Johannsen, Carl Gustav Viggo

    2014-01-01

    Segmentation of users can help libraries in the process of understanding user similarities and differences. Segmentation can also form the basis for selecting segments of target users and for developing tailored services for specific target segments. Several approaches and techniques have been...... tested in library contexts and the aim of this article is to identify the main approaches and to discuss their perspectives, including their strenghts and weaknesses in, especially, public library contexts. The purpose is also to prsent and discuss the results of a recent - 2014 - Danish library user...... segmentation project using computer-generated clusters. Compared to traditional marketing texts, this article also tries to identify user segments or images or metaphors by the library profession itself....

  7. Revitalização como valorização dos usuários e da equipe: experiência no centro POP / Revitalization as a valuation of users and team: Experience in center POP

    Directory of Open Access Journals (Sweden)

    Carla Regina Silva

    2017-11-01

    Full Text Available O relato apresenta um projeto de ambiência realizado no Centro de Referência Especializado para a População em Situação de Rua em parceria com o curso de Terapia Ocupacional da UFSCar. A construção recente de políticas, serviços e ações específicas para a população em situação de rua tem como desafio inverter a lógica e promover a cidadania e os direitos sociais junto a este grupo. As atividades desenvolvidas ocorreram de forma coletiva e colaborativa, incorporando sentido aos usuários. O resultado estético final produziu novos desejos de pertencimento e de qualificação do serviço.Abstract The report presents an ambience project carried out at the Specialized Reference Center for Homeless in partnership with the Occupational Therapy UFSCar' course. The recent construction of specific policies, services and actions for the homeless has the challenge of reversing logic and promoting citizenship and social rights for this group. The activities developed occurred in a collective and collaborative way, incorporating meaning to users. The final aesthetic result produced new desires of belonging and qualification of the service.Keywords: Occupational Therapy; Social Assistance; Homeless; Belonging; Professional Qualification Resumen El relato presenta un proyecto cerca estética ambiente desarrollado en un servicio de la asistencia social para la población de la calle en asociación con el curso de Terapia Ocupacional de la UFSCar.  La construcción reciente de la política, de los servicios y de las acciones específicas para la población que vive en la calle tiene el reto de invertir la lógica y la promoción de la ciudadanía y los derechos sociales a este grupo. Las actividades se llevaron a cabo de manera colectiva y colaborativa, la incorporación del sentido para los usuarios. El resultado estético final ha producido nuevos deseos de pertenencia y la calificación de lo servicio.Palabras-claves: Terapia ocupacional

  8. Medical equipment management

    CERN Document Server

    Willson, Keith; Tabakov, Slavik

    2013-01-01

    Know What to Expect When Managing Medical Equipment and Healthcare Technology in Your Organization As medical technology in clinical care becomes more complex, clinical professionals and support staff must know how to keep patients safe and equipment working in the clinical environment. Accessible to all healthcare professionals and managers, Medical Equipment Management presents an integrated approach to managing medical equipment in healthcare organizations. The book explains the underlying principles and requirements and raises awareness of what needs to be done and what questions to ask. I

  9. Data communication equipment

    International Nuclear Information System (INIS)

    Kim, Hak Seon; Lee, Sang Mok

    1998-02-01

    The contents of this book are introduction of data communication on definition, purpose and history, information terminal about data communication system and data transmission system, data transmit equipment of summary, transmission cable, data port, concentrator and front-end processor, audio communication equipment like phones, radio communication equipment of summary on foundation of electromagnetic waves, AM transmitter, AM receiver, FM receiver and FM transmitter, a satellite and mobile communication equipment such as earth station, TT and C and Cellular phone, video telephone and new media apparatus.

  10. Evaluation tests of the Instrumentation and Control equipment to use in nuclear power plants: its contribution to the improvement and quality certification of the Brazilian equipment

    International Nuclear Information System (INIS)

    Menezes, R.H.M. de; Peluso, M.A.V.

    1984-01-01

    This work presents the procedures used to evaluate Instrumentation Control equipment and reports the experience of integration among instrument user, manufacturer and test institution. It covers tests for equipments for conventional user and for specific application in Nuclear Power Stations. (Author) [pt

  11. Development of electric discharge equipment for small specimen sampling

    International Nuclear Information System (INIS)

    Okamoto, Koji; Kitagawa, Hideaki; Kusumoto, Junichi; Kanaya, Akihiro; Kobayashi, Toshimi

    2009-01-01

    We have developed the on-site electric discharge sampling equipment that can effectively take samples such as small specimens from the surface portion of the plant components. Compared with the conventional sampling equipment, our sampling equipment can take samples that are thinner in depth and larger in area. In addition, the affection to the equipment can be held down to the minimum, and the thermally-affected zone of the material due to electric discharge is small, which is to be ignored. Therefore, our equipment is excellent in taking samples for various tests such as residual life evaluation.

  12. The UK market for gaseous emissions control equipment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    The report analyses the changes in demand for gaseous emissions control equipment in the United Kingdom over the next 5 years. It discusses the factors affecting demand such as legislation reporting of environmental performance, and economic factors. It looks at environmental expenditure by UK industry. Markets are examined, for VOC abatement systems; thermal incinerators; adsorption equipment; catalytic oxidisers; absorption equipment; biological treatments; cryogenic equipment; SO{sub x} abatement equipment; wet FGD; wet dry FGD, dry scrubbers; NOx abatement systems; selective catalytic reduction; and selective non-catalytic reduction. Profiles are given of 16 leading suppliers.

  13. Initial screening of thermal desorption for soil remediation

    International Nuclear Information System (INIS)

    Yezzi, J.J. Jr.; Tafuri, A.N.; Rosenthal, S.; Troxler, W.L.

    1994-01-01

    Petroleum-contaminated soils--caused by spills, leaks, and accidental discharges--exist at many sites throughout the United States. Thermal desorption technologies which are increasingly being employed to treat these soils, have met soil cleanup criteria for a variety of petroleum products. Currently the United States Environmental Protection Agency is finalizing a technical report entitled Use of Thermal Desorption for Treating Petroleum-Contaminated Soils to assist remedial project managers, site owners, remediation contractors, and equipment vendors in evaluating the use of thermal desorption technologies for petroleum-contaminated soil applications. The report will present a three-level screening method to help a reader predict the success of applying thermal desorption at a specific site. The objective of screening level one is to determine the likelihood of success in a specific application of thermal desorption. It will take into account procedures for collecting and evaluating data on site characteristics, contaminant characteristics, soil characteristics, and regulatory requirements. This level will establish whether or not thermal desorption should be evaluated further for site remediation, whether treatment should occur on-site or off-site, and if on-site is a viable option, what system size will be most cost-effective. The scope of this paper addresses only screening level one which provides a preliminary assessment of the applicability of thermal desorption to a particular site. This topic encompasses worksheets that are an integral part of the ''user friendly'' screening process. Level one screening provides a foundation for the subsequent two levels which follow a similar ''user friendly'' worksheet approach to evaluating thermal desorption technologies and establishing costs for thermal desorption in an overall remediation project

  14. Capital Equipment Replacement Decisions

    OpenAIRE

    Batterham, Robert L.; Fraser, K.I.

    1995-01-01

    This paper reviews the literature on the optimal replacement of capital equipment, especially farm machinery. It also considers the influence of taxation and capital rationing on replacement decisions. It concludes that special taxation provisions such as accelerated depreciation and investment allowances are unlikely to greatly influence farmers' capital equipment replacement decisions in Australia.

  15. Establishment of nuclear equipment qualification system

    International Nuclear Information System (INIS)

    Joo, Po Kook; Lim, Nam Jin; Lee, Young Gun

    2003-04-01

    This study is carried out by KEARI(Korea Atomic Energy Research Institute) as the lead organization in cooperation with KIMM(Korea Institute of Machinery and Materials), KTL(Korea Testing Laboratory) and KRISS(Korea Research Institute of Standards and Science) to construct a basis of efficient management of nuclear equipment qualification business by expanding test equipment of each of participating organization, and developing qualification technologies. As for KIMM, control system of large scale shaker was replaced with advanced system, and LOCA(Loss of Coolant Accident) test facility was installed. KTL is now capable of conducting seismic tests of nuclear I and C as a result of installation of seismic test equipment during the first two project years. KRISS participated in the Project with a view to have large scale EMI test equipment and related technologies. In parallel with expansion of test equipment, a industrial-educational-research cooperation committee, as an intermediate step toward integrated equipment qualification system to maximize the usage of test equipment, was established and cooperation methods were investigated. As a result, Korea Nuclear Equipment Qualification Association, an corporate juridical person, was established. Research on development of thermal and radiation aging test technology of nuclear materials was carried out by Hanyang University and SECO(Saehan Engineering and Qualification Co., Ltd.). Integrated Equipment Qualification Database was developed which contains material test data, equipment qualification data and other EQ related informations. Standard qualification procedures were developed in order for test laboratories and manufacturers to establish design requirements and to efficiently perform tests

  16. A Precoded OFDMA System with User Cooperation

    NARCIS (Netherlands)

    Yu, Yao; Yatawatta, Sarod; Petropulu, Athina P.

    2010-01-01

    A new cooperative scheme for a two-user orthogonal frequency division multiple access (OFDMA) uplink communication scenario is proposed. Each user is equipped with one transmit/receive antenna. Before transmission, inter-block linear precoding is introduced to pairs of blocks. The cooperative

  17. High-Thermal-Conductivity Fabrics

    Science.gov (United States)

    Chibante, L. P. Felipe

    2012-01-01

    Heat management with common textiles such as nylon and spandex is hindered by the poor thermal conductivity from the skin surface to cooling surfaces. This innovation showed marked improvement in thermal conductivity of the individual fibers and tubing, as well as components assembled from them. The problem is centered on improving the heat removal of the liquid-cooled ventilation garments (LCVGs) used by astronauts. The current design uses an extensive network of water-cooling tubes that introduces bulkiness and discomfort, and increases fatigue. Range of motion and ease of movement are affected as well. The current technology is the same as developed during the Apollo program of the 1960s. Tubing material is hand-threaded through a spandex/nylon mesh layer, in a series of loops throughout the torso and limbs such that there is close, form-fitting contact with the user. Usually, there is a nylon liner layer to improve comfort. Circulating water is chilled by an external heat exchanger (sublimator). The purpose of this innovation is to produce new LCVG components with improved thermal conductivity. This was addressed using nanocomposite engineering incorporating high-thermalconductivity nanoscale fillers in the fabric and tubing components. Specifically, carbon nanotubes were added using normal processing methods such as thermoplastic melt mixing (compounding twin screw extruder) and downstream processing (fiber spinning, tubing extrusion). Fibers were produced as yarns and woven into fabric cloths. The application of isotropic nanofillers can be modeled using a modified Nielsen Model for conductive fillers in a matrix based on Einstein s viscosity model. This is a drop-in technology with no additional equipment needed. The loading is limited by the ability to maintain adequate dispersion. Undispersed materials will plug filtering screens in processing equipment. Generally, the viscosity increases were acceptable, and allowed the filled polymers to still be

  18. Development of diaphragm automatic homing equipment

    International Nuclear Information System (INIS)

    Kobayashi, Hidetoshi; Yamada, Koji; Moriya, Shinichi; Koike, Jiro; Okabe, Masao; Oyama, Akihiro.

    1996-01-01

    In steam-turbine overhaul inspection, one of the most important processes is to remove rust and deposited contaminants on the surface of turbine parts, while the turbine is in operation, to recover thermal efficiency and prepare good surface conditions for color penetrant inspection. These processes generally are done by dry honing, but this generates dust. To protect laborers against these conditions, Hitachi, Ltd. has developed automatic honing equipment for the diaphragms of the nuclear steam turbine. This equipment was first used in the first annual inspection and overhaul of Hamaoka Nuclear Power Plant No.4 of Chubu Electric Power Inc. (author)

  19. Preliminary degradation process study of infectious biological waste in a 5 k W thermal plasma equipment.; Estudio Preliminar de Proceso de degradacion de residuos biologico-infecciosos en un equipo de plasma termico de 5 kW

    Energy Technology Data Exchange (ETDEWEB)

    Xochihua S M, M C

    1998-12-31

    This work is a preliminary study of infectious biological waste degradation process by thermal plasma and was made in Thermal Plasma Applications Laboratory of Environmental Studies Department of the National Institute of Nuclear Research (ININ). Infectious biological waste degradation process is realized by using samples such polyethylene, cotton, glass, etc., but the present study scope is to analyze polyethylene degradation process with mass and energy balances involved. Degradation method is realized as follow: a polyethylene sample is put in an appropriated crucible localized inside a pyrolysis reactor chamber, the plasma jet is projected to the sample, by the pyrolysis phenomena the sample is degraded into its constitutive particles: carbon and hydrogen. Air was utilized as a recombination gas in order to obtain the higher percent of CO{sub 2} if amount of O{sub 2} is greater in the recombination gas, the CO generation is reduced. The effluent gases of exhaust pyrolysis reactor through are passed through a heat exchanger to get cooled gases, the temperature water used is 15 Centigrade degrees. Finally the gases was tried into absorption tower with water as an absorbent fluid. Thermal plasma degradation process is a very promising technology, but is necessary to develop engineering process area to avail all advantages of thermal plasma. (Author).

  20. HVAC systems and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.T. (Linford Air and Refrigeration Company, Oakland, CA (US))

    1990-02-01

    The author discusses the section of the ASHRAE Standard 90.1-1989 which addresses HVAC systems and equipment. New features of HVAC systems mandatory general requirements are described. New prescriptive requirements are detailed.

  1. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  2. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  3. Power Electronics Thermal Management | Transportation Research | NREL

    Science.gov (United States)

    Power Electronics Thermal Management Power Electronics Thermal Management A photo of water boiling in liquid cooling lab equipment. Power electronics thermal management research aims to help lower the investigates and develops thermal management strategies for power electronics systems that use wide-bandgap

  4. Concerning equipment procurement for NPPs

    International Nuclear Information System (INIS)

    Pana, N.

    2002-01-01

    After a stagnation in investments for nuclear power which extended over a period of 10-15 years, assessments done by energy forecast institutes, as well as, evaluations by UE institutions, OECD, and DOE (USA) point to the conclusion solid and argued that the electric energy of nuclear origin will record a new boost beginning probably with the year 2005. Particular efforts were concentrated upon improving the performances of existing plants and, on the other hand, towards new, evolutionary concepts in nuclear engineering. Advanced equipment for nuclear reactors and plants resulted and were already implemented. In Europe construction of both advanced PWR and BWR type reactors are underway. The paper consider the issues of Romanian nuclear power and presents the prospects for advanced CANDU reactors in connection with the Romania's infrastructure and necessities. The problem of modernizing the equipment and components for NPP is discussed in the context of financing and investment conditions. In conclusion, the share of nuclear power in Romania is expected to rise in order to compensate the decline in fossil fuel thermal power and to better solve the environmental issues

  5. A complex method of equipment replacement planning. An advanced plan for the replacement of medical equipment.

    Science.gov (United States)

    Dondelinger, Robert M

    2004-01-01

    This complex method of equipment replacement planning is a methodology; it is a means to an end, a process that focuses on equipment most in need of replacement, rather than the end itself. It uses data available from the maintenance management database, and attempts to quantify those subjective items important [figure: see text] in making equipment replacement decisions. Like the simple method of the last issue, it is a starting point--albeit an advanced starting point--which the user can modify to fit their particular organization, but the complex method leaves room for expansion. It is based on sound logic, documented facts, and is fully defensible during the decision-making process and will serve your organization well as provide a structure for your equipment replacement planning decisions.

  6. Equipment support for the implementation of safeguards

    International Nuclear Information System (INIS)

    Arlt, R.; Bosler, G.; Goldfarb, M.; Schanfein, M.; Whichello, J.

    2001-01-01

    Full text: The provision of effective, reliable, and user-friendly equipment needed for the implementation of safeguards is one of the main objectives of the Division of Technical Services (SOTS) in the Department of Safeguards. As an outcome of a review by an independent external consultant firm, the instrumentation sections of the SGTS were reorganized in January 2001 into two new sections, the Section for NDA Systems and Seals (TNS) and Section for Installed Systems (TIE). Each section has 'cradle-to-grave' responsibilities for development, implementation, maintenance, and decommissioning of safeguards instruments and measurement systems. Unattended assay, monitoring and surveillance instruments are the responsibility of TIE while attended nondestructive assay (NDA) instruments and seals are handled by TNS. The principal goals of both sections are to define equipment requirements based on Departmental needs, to coordinate Support Programme tasks concerning development and implementation activities, to provide system engineering of commercial components, manage laboratory and to do field testing and prove system suitability for defined safeguards applications. In addition both sections coordinate equipment and supply needs for the Department, including acquisition, preparation, servicing, installation, commissioning, troubleshooting, maintenance and repair, ensuring their availability when needed. As required, TIE and TNS provide specialized field support to the Operations Divisions. Each section is working to standardize equipment as much as possible and reduce the number of instruments performing the same function. This reduces both inspector and technician training, required parts inventories, and overall life-cycle costs. Development based on User Needs from the Operations Divisions follows a strict quality control program that includes a thorough qualification testing procedure with the last phase being field-testing under actual facility conditions. A

  7. CSTEM User Manual

    Science.gov (United States)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  8. User 2020

    DEFF Research Database (Denmark)

    Porras, Jari; Heikkinen, Kari; Kinnula, Marianne

    2014-01-01

    an effect on their future needs. Human needs have been studied much longer than user generations per se. Psychologist Maslow presented a characterization of human needs as early as 1943. This basic characterization was later studied with an evolving environment in mind. Although the basic needs have...

  9. T-3 cask users' manual. Revision 1

    International Nuclear Information System (INIS)

    1986-06-01

    This user's manual for the T-C spent fuel cask provides information on: operating procedures; inspection and maintenance procedures; criticality evaluation; shielding evaluation; thermal evaluation; structural evaluation; and limitations

  10. Hanford inventory program user's manual

    International Nuclear Information System (INIS)

    Hinkelman, K.C.

    1994-01-01

    Provides users with instructions and information about accessing and operating the Hanford Inventory Program (HIP) system. The Hanford Inventory Program is an integrated control system that provides a single source for the management and control of equipment, parts, and material warehoused by Westinghouse Hanford Company in various site-wide locations. The inventory is comprised of spare parts and equipment, shop stock, special tools, essential materials, and convenience storage items. The HIP replaced the following systems; ACA, ASP, PICS, FSP, WSR, STP, and RBO. In addition, HIP manages the catalog maintenance function for the General Supplies inventory stocked in the 1164 building and managed by WIMS

  11. XTV users guide

    International Nuclear Information System (INIS)

    Dearing, J.F.; Johns, R.C.

    1996-09-01

    XTV is an X-Windows based Graphical User Interface for viewing results of Transient Reactor Analysis Code (TRAC) calculations. It provides static and animated color mapped visualizations of both thermal-hydraulic and heat conduction components in a TRAC model of a nuclear power plant, as well as both on-screen and hard copy two-dimensional plot capabilities. XTV is the successor to TRAP, the former TRAC postprocessor using the proprietary DISSPLA graphics library. This manual describes Version 2.0, which requires TRAC version 5.4.20 or later for full visualization capabilities

  12. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  13. Prioritizing equipment for replacement.

    Science.gov (United States)

    Capuano, Mike

    2010-01-01

    It is suggested that clinical engineers take the lead in formulating evaluation processes to recommend equipment replacement. Their skill, knowledge, and experience, combined with access to equipment databases, make them a logical choice. Based on ideas from Fennigkoh's scheme, elements such as age, vendor support, accumulated maintenance cost, and function/risk were used.6 Other more subjective criteria such as cost benefits and efficacy of newer technology were not used. The element of downtime was also omitted due to the data element not being available. The resulting Periop Master Equipment List and its rationale was presented to the Perioperative Services Program Council. They deemed the criteria to be robust and provided overwhelming acceptance of the list. It was quickly put to use to estimate required capital funding, justify items already thought to need replacement, and identify high-priority ranked items for replacement. Incorporating prioritization criteria into an existing equipment database would be ideal. Some commercially available systems do have the basic elements of this. Maintaining replacement data can be labor-intensive regardless of the method used. There is usually little time to perform the tasks necessary for prioritizing equipment. However, where appropriate, a clinical engineering department might be able to conduct such an exercise as shown in the following case study.

  14. Methods of evaluating protective clothing relative to heat and cold stress: thermal manikin, biomedical modeling, and human testing.

    Science.gov (United States)

    O'Brien, Catherine; Blanchard, Laurie A; Cadarette, Bruce S; Endrusick, Thomas L; Xu, Xiaojiang; Berglund, Larry G; Sawka, Michael N; Hoyt, Reed W

    2011-10-01

    Personal protective equipment (PPE) refers to clothing and equipment designed to protect individuals from chemical, biological, radiological, nuclear, and explosive hazards. The materials used to provide this protection may exacerbate thermal strain by limiting heat and water vapor transfer. Any new PPE must therefore be evaluated to ensure that it poses no greater thermal strain than the current standard for the same level of hazard protection. This review describes how such evaluations are typically conducted. Comprehensive evaluation of PPE begins with a biophysical assessment of materials using a guarded hot plate to determine the thermal characteristics (thermal resistance and water vapor permeability). These characteristics are then evaluated on a thermal manikin wearing the PPE, since thermal properties may change once the materials have been constructed into a garment. These data may be used in biomedical models to predict thermal strain under a variety of environmental and work conditions. When the biophysical data indicate that the evaporative resistance (ratio of permeability to insulation) is significantly better than the current standard, the PPE is evaluated through human testing in controlled laboratory conditions appropriate for the conditions under which the PPE would be used if fielded. Data from each phase of PPE evaluation are used in predictive models to determine user guidelines, such as maximal work time, work/rest cycles, and fluid intake requirements. By considering thermal stress early in the development process, health hazards related to temperature extremes can be mitigated while maintaining or improving the effectiveness of the PPE for protection from external hazards.

  15. Smart Building: Decision Making Architecture for Thermal Energy Management.

    Science.gov (United States)

    Uribe, Oscar Hernández; Martin, Juan Pablo San; Garcia-Alegre, María C; Santos, Matilde; Guinea, Domingo

    2015-10-30

    Smart applications of the Internet of Things are improving the performance of buildings, reducing energy demand. Local and smart networks, soft computing methodologies, machine intelligence algorithms and pervasive sensors are some of the basics of energy optimization strategies developed for the benefit of environmental sustainability and user comfort. This work presents a distributed sensor-processor-communication decision-making architecture to improve the acquisition, storage and transfer of thermal energy in buildings. The developed system is implemented in a near Zero-Energy Building (nZEB) prototype equipped with a built-in thermal solar collector, where optical properties are analysed; a low enthalpy geothermal accumulation system, segmented in different temperature zones; and an envelope that includes a dynamic thermal barrier. An intelligent control of this dynamic thermal barrier is applied to reduce the thermal energy demand (heating and cooling) caused by daily and seasonal weather variations. Simulations and experimental results are presented to highlight the nZEB thermal energy reduction.

  16. Smart Building: Decision Making Architecture for Thermal Energy Management

    Directory of Open Access Journals (Sweden)

    Oscar Hernández Uribe

    2015-10-01

    Full Text Available Smart applications of the Internet of Things are improving the performance of buildings, reducing energy demand. Local and smart networks, soft computing methodologies, machine intelligence algorithms and pervasive sensors are some of the basics of energy optimization strategies developed for the benefit of environmental sustainability and user comfort. This work presents a distributed sensor-processor-communication decision-making architecture to improve the acquisition, storage and transfer of thermal energy in buildings. The developed system is implemented in a near Zero-Energy Building (nZEB prototype equipped with a built-in thermal solar collector, where optical properties are analysed; a low enthalpy geothermal accumulation system, segmented in different temperature zones; and an envelope that includes a dynamic thermal barrier. An intelligent control of this dynamic thermal barrier is applied to reduce the thermal energy demand (heating and cooling caused by daily and seasonal weather variations. Simulations and experimental results are presented to highlight the nZEB thermal energy reduction.

  17. Utilization of old vibro-acoustic measuring equipment to grasp basic concepts of vibration measurements

    DEFF Research Database (Denmark)

    Darula, Radoslav

    2013-01-01

    The aim of the paper is to show that even old vibro-acoustic (analog) equipment can be used as a very suitable teaching equipment to grasp basic principles of measurements in an era, when measurement equipments are more-or-less treated as ‘black-boxes’, i.e. the user cannot see directly how...

  18. Radioactive decontamination of equipment

    International Nuclear Information System (INIS)

    1982-03-01

    After a recall of some definitions relating to decontamination techniques and of the regulation into effect, the principles to be respected to arrange rationally work zones are quoted while insisting more particularly on the types of coatings which facilitate maintenance operations and the dismantling of these installations. Then, the processes and equipments to use in decontamination units for routine or particular operations are described; the list of recommended chemical products to decontaminate the equipment is given. The influence of these treatments on the state and the duration of life of equipments is studied, and some perfectible methods are quoted. In the appendix, are given: the limits of surface contamination accepted in the centers; a standard project which defines the criteria of admissible residual contamination in wastes considered as cold wastes; some remarks on the interest that certain special ventilation and air curtain devices for the protection of operators working on apparatus generating contaminated dusts [fr

  19. 46 CFR 160.176-21 - User manuals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false User manuals. 160.176-21 Section 160.176-21 Shipping...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-21 User manuals. (a) The manufacturer must develop a user's manual for each model of inflatable lifejacket. The content of the manual...

  20. Equipment Operational Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

    2009-06-11

    The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

  1. Charging equipment. Ladegeraet

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, E

    1981-09-17

    The invention refers to a charging equipment, particularly on board charging equipment for charging traction batteries of an electric vehicle from the AC mains supply, consisting of a DC converter, which contains a controlled power transistor, a switching off unloading circuit and a power transmitter, where the secondary winding is connected in series with a rectifier diode, and a smoothing capacitor is connected in parallel with this series circuit. A converter module is provided, which consists of two DC voltage converters, whose power transistors are controlled by a control circuit in opposition with a phase displacement of 180/sup 0/.

  2. Methodology for assessing laser-based equipment

    Science.gov (United States)

    Pelegrina-Bonilla, Gabriel; Hermsdorf, Jörg; Thombansen, Ulrich; Abels, Peter; Kaierle, Stefan; Neumann, Jörg

    2017-10-01

    Methodologies for the assessment of technology's maturity are widely used in industry and research. Probably the best known are technology readiness levels (TRLs), initially pioneered by the National Aeronautics and Space Administration (NASA). At the beginning, only descriptively defined TRLs existed, but over time, automated assessment techniques in the form of questionnaires emerged in order to determine TRLs. Originally TRLs targeted equipment for space applications, but the demands on industrial relevant equipment are partly different in terms of, for example, overall costs, product quantities, or the presence of competitors. Therefore, we present a commonly valid assessment methodology with the aim of assessing laser-based equipment for industrial use, in general. The assessment is carried out with the help of a questionnaire, which allows for a user-friendly and easy accessible way to monitor the progress from the lab-proven state to the application-ready product throughout the complete development period. The assessment result is presented in a multidimensional metric in order to reveal the current specific strengths and weaknesses of the equipment development process, which can be used to direct the remaining development process of the equipment in the right direction.

  3. SHARP User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay S. [Argonne National Lab. (ANL), Argonne, IL (United States); Rahaman, Ronald O. [Argonne National Lab. (ANL), Argonne, IL (United States); Solberg, Jerome [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-31

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  4. SHARP User Manual

    International Nuclear Information System (INIS)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.; Mahadevan, Vijay S.; Rahaman, Ronald O.; Solberg, Jerome

    2016-01-01

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  5. Experimental equipment, ch. 6

    International Nuclear Information System (INIS)

    Boomstra, F.; Hoogenboom, A.M.; Prins, C.M.; Strasters, B.A.; Vermeer, A.; Wit, P. de; Zwol, N.A. van.

    1977-01-01

    The experimental equipment in use at Utrecht university is discussed. Attention is paid to the tandem Van de Graaff accelerator and the 4MV and 1MV accelerators. The detection systems for gamma-ray spectroscopy are reviewed with emphasis on the compton-suppression spectrometer. The data-handling system used for experiments with the tandem is also briefly discussed

  6. Equipment gift to Monaco

    International Nuclear Information System (INIS)

    1970-01-01

    Research work at the Agency's Laboratory of Marine Radioactivity in Monaco, including that concerned with pollution of the sea, has been made more effective by its latest acquisition of equipment. This is a spectrophotometer donated by the Federal Republic of Germany. (author)

  7. Lifetime of Mechanical Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Leland, K.

    1999-07-01

    The gas plant at Kaarstoe was built as part of the Statpipe gas transport system and went on stream in 1985. In 1993 another line was routed from the Sleipner field to carry condensate, and the plant was extended accordingly. Today heavy additional supply- and export lines are under construction, and the plant is extended more than ever. The main role of the factory is to separate the raw gas into commercial products and to pump or ship it to the markets. The site covers a large number of well-known mechanical equipment. This presentation deals with piping, mechanical and structural disciplines. The lifetime of mechanical equipment is often difficult to predict as it depends on many factors, and the subject is complex. Mechanical equipment has been kept in-house, which provides detailed knowledge of the stages from a new to a 14 years old plant. The production regularity has always been very high, as required. The standard of the equipment is well kept, support systems are efficient, and human improvisation is extremely valuable.

  8. Safeguards techniques and equipment

    International Nuclear Information System (INIS)

    1997-01-01

    The current booklet is intended to give a full and balanced description of the techniques and equipment used for both nuclear material accountancy and containment and surveillance measures, and for the new safeguards measure of environmental sampling. As new verification measures continue to be developed, the material in the booklet will be periodically reviewed and updated versions issued. (author)

  9. Equipping tomorrow's fire manager

    Science.gov (United States)

    Christopher A. Dicus

    2008-01-01

    Fire managers are challenged with an ever-increasing array of both responsibilities and critics. As in the past, fire managers must master the elements of fire behavior and ecology using the latest technologies. In addition, today’s managers must be equipped with the skills necessary to understand and liaise with a burgeoning group of vocal stakeholders while also...

  10. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  11. Orphee reactor experimental equipment

    International Nuclear Information System (INIS)

    1987-01-01

    Experimental equipment around the ORPHEE reactor is presented. The neutron source; and the spectrometers and sample environment (inelastic and quasi-elastic scattering, elastic scattering, spread scattering, small angle scattering) are described. An experiment proposal and reports guide is supplied [fr

  12. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  13. Underground coal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Chadwick, J.

    2002-12-01

    This paper reports on increasing automation and enhanced productivity on longwalls, new development cutting and bolting technologies and haulage systems. Amongst equipment discussed is DBT's Electra series EL3000 shearer, the Dosco LH1400 roadheader with onboard bolters, and Joy 12 CM30 continuous miners. 4 photos.

  14. Evaluation and development of direct burning natural gas industrial equipment in the food sector; Avaliacao e desenvolvimento de equipamentos industriais de queima direta de gas natural no setor de alimentos

    Energy Technology Data Exchange (ETDEWEB)

    Schwob, Marcelo; Morales, Maria Elizabeth; Henriques, Mauricio; Guimaraes, Marcio; Tapia, Roberto; Rodrigues, Joaquim; Faccion, Alexandre [Instituto Nacional de Tecnologia (INT), Rio de Janeiro, RJ (Brazil)

    2004-07-01

    The aim of this study, focused in the food sector, is evaluate and develop technologies used in equipment of direct burning natural gas, as ovens and driers of common use in the toasting coffee, noodles and biscuits industries. We have developed an archetype of oven for baking, seeking to incorporate new technological concepts but showing operational conditions of great attractiveness for the users of this kind of equipment. Above all, aiming the optimization of the technologies to improve the energy efficiency, to reduce costs and to increase the operational security. Thus, a survey of the thermal equipment in the mentioned industrial sector was made, followed of an evaluation of the technical possibilities of its incorporation in that sector, adaptations and the modifications of engineering projects, identifying the possibilities of productivity increase, improvement of quality and greater competitiveness, as well as the reduction of atmospheric emissions. So, It has been proposed solutions as the decentralized use of the thermal energy, recovery of heat of exhaustion gases, optimization of the thermal insulation, reduction of thermal inertia and the automatization of the control of the combustion in ovens and/or driers of the mentioned sectors. The main results of this study are: the possibility of reduction of, 32 to 37% in the consumption of thermal energy in the ovens of biscuit production, of 12 to 15% in the toasting of coffee and 20 to 30% in the processes of noodles production. Saving of around 25% would be expected in the small bearing ovens for baking. (author)

  15. Thermal Reactor Safety

    International Nuclear Information System (INIS)

    1980-06-01

    Information is presented concerning fire risk and protection; transient thermal-hydraulic analysis and experiments; class 9 accidents and containment; diagnostics and in-service inspection; risk and cost comparison of alternative electric energy sources; fuel behavior and experiments on core cooling in LOCAs; reactor event reporting analysis; equipment qualification; post facts analysis of the TMI-2 accident; and computational methods

  16. Thermal Reactor Safety

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    Information is presented concerning fire risk and protection; transient thermal-hydraulic analysis and experiments; class 9 accidents and containment; diagnostics and in-service inspection; risk and cost comparison of alternative electric energy sources; fuel behavior and experiments on core cooling in LOCAs; reactor event reporting analysis; equipment qualification; post facts analysis of the TMI-2 accident; and computational methods.

  17. Standard guide for metallographic preparation of thermal sprayed coatings

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide covers recommendations for sectioning, cleaning, mounting, grinding, and polishing to reveal the microstructural features of thermal sprayed coatings (TSCs) and the substrates to which they are applied when examined microscopically. Because of the diversity of available equipment, the wide variety of coating and substrate combinations, and the sensitivity of these specimens to preparation technique, the existence of a series of recommended methods for metallographic preparation of thermal sprayed coating specimens is helpful. Adherence to this guide will provide practitioners with consistent and reproducible results. Additional information concerning standard practices for metallographic preparation can be found in Practice E 3. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitatio...

  18. The users centered design of a new digital fluorometer

    International Nuclear Information System (INIS)

    Farias, Marcos S.; Santos, Isaac J.A.L. dos; Grecco, Claudio H.S.; Pedrosa, Paulo S.; Colthurst, Carlos M.; Szabo, Andre P.

    2009-01-01

    The fluorometer is the equipment used in chemical analysis laboratories, research institutes and nuclear fuel cycle companies. This equipment measures an unknown amount of uranium in ores, rivers, etc. The fluorometer functioning is based on the uranium fluorescence when submitted to the ultraviolet radiation incidence. The fluorescence is measured by an electronic optic system with optics filters, photomultiplier tube, and a current amplifier. The user centered design involves the user in the product development in all phases of the design process. Users are not simply consulted at the beginning of the design process and evaluated the system at the end; they are treated as partners throughout the design process. The user centered design emphasizes the needs and abilities of the users and improves the usability of the equipment. The activity centered design emphasizes the development of the equipment with a deep understanding of the users activities and of the current work practices of the users. The aim of this paper is to present a methodological framework that contributes to the design and evaluation of a new digital fluorometer towards an approach related to the users and their activities. This methodological framework includes users-based testing, interviews, questionnaires, human factors standards and guidelines, the users activity analysis and users satisfaction questionnaire. (author)

  19. COLUMBUS as Engineering Testbed for Communications and Multimedia Equipment

    Science.gov (United States)

    Bank, C.; Anspach von Broecker, G. O.; Kolloge, H.-G.; Richters, M.; Rauer, D.; Urban, G.; Canovai, G.; Oesterle, E.

    2002-01-01

    The paper presents ongoing activities to prepare COLUMBUS for communications and multimedia technology experiments. For this purpose, Astrium SI, Bremen, has studied several options how to best combine the given system architecture with flexible and state-of-the-art interface avionics and software. These activities have been conducted in coordination with, and partially under contract of, DLR and ESA/ESTEC. Moreover, Astrium SI has realized three testbeds for multimedia software and hardware testing under own funding. The experimental core avionics unit - about a half double rack - establishes the core of a new multi-user experiment facility for this type of investigation onboard COLUMBUS, which shall be available to all users of COLUMBUS. It allows for the connection of 2nd generation payload, that is payload requiring broadband data transfer and near-real-time access by the Principal Investigator on ground, to test highly interactive and near-realtime payload operation. The facility is also foreseen to test new equipment to provide the astronauts onboard the ISS/COLUMBUS with bi- directional hi-fi voice and video connectivity to ground, private voice coms and e-mail, and a multimedia workstation for ops training and recreation. Connection to an appropriate Wide Area Network (WAN) on Earth is possible. The facility will include a broadband data transmission front-end terminal, which is mounted externally on the COLUMBUS module. This Equipment provides high flexibility due to the complete transparent transmit and receive chains, the steerable multi-frequency antenna system and its own thermal and power control and distribution. The Equipment is monitored and controlled via the COLUMBUS internal facility. It combines several new hardware items, which are newly developed for the next generation of broadband communication satellites and operates in Ka -Band with the experimental ESA data relay satellite ARTEMIS. The equipment is also TDRSS compatible; the open loop

  20. PARFUME User's Guide

    International Nuclear Information System (INIS)

    Hamman, Kurt

    2010-01-01

    PARFUME, a fuel performance analysis and modeling code, is being developed at the Idaho National Laboratory for evaluating gas reactor coated particle fuel assemblies for prismatic, pebble bed, and plate type fuel geometries. The code is an integrated mechanistic analysis tool that evaluates the thermal, mechanical, and physico-chemical behavior of coated fuel particles (TRISO) and the probability for fuel failure given the particle-to-particle statistical variations in physical dimensions and material properties that arise during the fuel fabrication process. Using a robust finite difference numerical scheme, PARFUME is capable of performing steady state and transient heat transfer and fission product diffusion analyses for the fuel. Written in FORTRAN 90, PARFUME is easy to read, maintain, and modify. Currently, PARFUME is supported only on MS Windows platforms. This document represents the initial version of the PARFUME User Guide, a supplement to the PARFUME Theory and Model Basis Report which describes the theoretical aspects of the code. User information is provided including: (1) code development, (2) capabilities and limitations, (3) installation and execution, (4) user input and output, (5) sample problems, and (6) error messages. In the near future, the INL plans to release a fully benchmarked and validated beta version of PARFUME.

  1. IAS 16 Property, Plant and Equipment - A Closer Look

    OpenAIRE

    Muthupandian, K S

    2009-01-01

    The International Accounting Standards Committee issued the the International Accounting Standard 16 Property, Plant and Equipment. The objective of IAS 16 is to prescribe the accounting treatment for Property, Plant and Equipment (PPE) so that users of the financial statements can discern information about an entity's investment in its PPE and the changes in such investment. The principal issues in accounting for PPE are the recognition of the assets, the determination of their carrying amou...

  2. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  3. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  4. Equipment cost optimization

    International Nuclear Information System (INIS)

    Ribeiro, E.M.; Farias, M.A.; Dreyer, S.R.B.

    1995-01-01

    Considering the importance of the cost of material and equipment in the overall cost profile of an oil company, which in the case of Petrobras, represents approximately 23% of the total operational cost or 10% of the sales, an organization for the optimization of such costs has been established within Petrobras. Programs are developed aiming at: optimization of life-cycle cost of material and equipment; optimization of industrial processes costs through material development. This paper describes the methodology used in the management of the development programs and presents some examples of concluded and ongoing programs, which are conducted in permanent cooperation with suppliers, technical laboratories and research institutions and have been showing relevant results

  5. X-ray equipment

    International Nuclear Information System (INIS)

    Redmayne, I.G.B.

    1988-01-01

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.)

  6. X-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.G.B.

    1988-01-06

    The patent concerns a warning and protection system for mobile x-ray equipment used for 'on site' radiography, so that workers in the vicinity of such a working unit can be alerted to its presence. The invention is a local repeater warning system which gives a preliminary warning that energisation of the tubehead is imminent, as well as a switch near the tubehead to abort or inhibit energisation. The latter switch allows personnel caught in the vicinity of the tubehead to prevent energisation. The preliminary warning may be flashing lamps or by a klaxon. The control unit for the equipment may include a monitoring circuit to detect failure of the warning light or klaxon. (U.K.).

  7. Tube for irradiation equipment

    International Nuclear Information System (INIS)

    Goehrich, K.; Vogt, H.

    1979-01-01

    This patent describes a tube for irradiation equipment for limiting an emergent beam, with a baseplate, possessing a central aperture, intended for attaching to the equipment, as well as four carrier plates, each of which possesses a limiting edge and a sliding edge located at right angles thereto. The carrier plates are located parallel to the baseplate, the limiting edge of each carrier plate resting against the sliding edge of the adjacent carrier plate and each of the two mutually opposite pairs of carrier plates being displaceable, parallel to the direction of its sliding edges and symmetrically to the center of the transmission aperture, for the purpose of continuously varying the transmission aperture defined by the limiting edges, during which displacement each of the displaced carrier plates carries with it the carrier plate, resting against the limiting edge of the former plate, parallel to the direction of the limiting edge of the latter plate. 8 claims

  8. Equipment for isotope diagnostics

    International Nuclear Information System (INIS)

    Platz, W.

    1976-01-01

    The invention concerns an improvement of equipment for isotope diagnostics allowing to mark special intensity ranges of the recorded measurements by means of different colors. For undisturbed operation it is of advantage to avoid electric circuits between movable and unmovable parts of the color recorder. According to the invention, long gear wheels of glass fiber-reinforced polyamide are used for these connections. (ORU) [de

  9. Soviet equipment flies in

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    End of February 1977 a Soviet Ilyushin-76 heavy freight aircraft landed at Cointrin airport having on board fifty large wire proprtional chambers and associated apparatus, together weighing 10 tons, supplied by the Joint Institute for Nuclear Research, Dubna, USSR. The equipment was for the CERN- Dubna-Munich-Saclay experiment NA4 on deep inelastic muon scattering being set up in the North Area of SPS. See Weekly Bulletin 11/78.

  10. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  11. Equipment Obsolescence Management Program

    Energy Technology Data Exchange (ETDEWEB)

    Redmond, J.

    2014-07-01

    Nuclear Power Plant (NPP) Operators are challenged with securing reliable supply channels for safety related equipment due to equipment obsolescence. Many Original Equipment Manufacturers (OEMs) have terminated production of spare parts and product life-cycle support. The average component life cycles are much shorter than the NPP design life, which means that replacement components and parts for the original NPP systems are not available for the complete design life of the NPPs. The lack or scarcity of replacement parts adversely affects plant reliability and ultimately the profitability of the affected NPPs. This problem is further compounded when NPPs pursue license renewal and approval for plant-life extension. A reliable and predictable supply of replacement co components is necessary for NPPs to remain economically competitive and meet regulatory requirements and guidelines. Electrical and I and C components, in particular, have short product life cycles and obsolescence issues must be managed pro actively and not reactively in order to mitigate the risk to the NPP to ensure reliable and economic NPP operation. (Author)

  12. Some perspective decisions for the regeneration system equipment of the thermal and nuclear power plants decreasing the probability of water ingress into the turbine and rotor acceleration by return steam flow

    Science.gov (United States)

    Trifonov, N. N.; Svyatkin, F. A.; Sintsova, T. G.; Ukhanova, M. G.; Yesin, S. B.; Nikolayenkova, E. K.; Yurchenko, A. Yu.; Grigorieva, E. B.

    2016-03-01

    The regeneration system heaters are one of the sources of possible ingress of the water into the turbine. The water penetrates into the turbine either at the heaters overflow or with the return flow of steam generated when the water being in the heater boils up in the dynamic operation modes or at deenergization of the power-generating unit. The return flow of steam and water is dangerous to the turbine blades and can result in the rotor acceleration. The known protective devices used to prevent the overflow of the low-pressure and high-pressure heaters (LPH and HPH), of the horizontal and vertical heaters of heating-system water (HWH and VWH), as well as of the deaerators and low-pressure mixing heaters (LPMH) were considered. The main protective methods of the steam and water return flows supplied by the heaters in dynamic operation modes or at deenergization of the power-generating unit are described. Previous operating experience shows that the available protections do not fully prevent water ingress into the turbine and the rotor acceleration and, therefore, the development of measures to decrease the possibility of ingress of the water into the turbine is an actual problem. The measures allowing eliminating or reducing the water mass in the heaters are expounded; some of them were designed by the specialists of OAO Polzunov Scientific and Development Association on Research and Design of Power Equipment (NPO CKTI) and are efficiently introduced at heat power plants and nuclear power plants. The suggested technical solutions allow reducing the possibility of the water ingress into the turbine and rotor acceleration by return steam flow in the dynamic operation modes or in the case of power generating unit deenergization. Some of these solutions have been tested in experimental-industrial exploitation and can be used in industry.

  13. Introduction of sample environment equipment for neutron scattering experiments

    International Nuclear Information System (INIS)

    Shimojo, Yutaka; Ihata, Yoshiaki; Kaneko, Koji; Takeda, Masayasu

    2013-02-01

    Neutron scattering experiments have been frequently performed under variety of sample conditions, such as various temperatures, pressures, magnetic fields and stresses, and those complex conditions to fully utilize superior properties of neutron. To this aim, a number of sample environment equipment, refrigerators, furnaces, pressure cells, superconducting magnets are equipped in JRR-3 to be used for experiments. In this document, all available sample environment equipment in both JRR-3 reactor and guide halls are summarized. We hope this document would help neutron scattering users to perform effective and excellent experiments. (author)

  14. Radiological equipment analyzed by specific developed phantoms and software

    International Nuclear Information System (INIS)

    Soto, M.; Campayo, J. M.; Mayo, P.; Verdu, G.; Rodenas, F.

    2010-10-01

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  15. Radiological equipment analyzed by specific developed phantoms and software

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Campayo, J. M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Mayo, P. [TITANIA Servicios Tecnologicos SL, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Verdu, G.; Rodenas, F., E-mail: m.soto@lainsa.co [ISIRYIM Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain)

    2010-10-15

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  16. Scientific Equipment Division - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2001-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: - designing of devices and equipment for experiments in physics, their mechanical construction and assembly. In particular, there are vacuum chambers and installations for HV and UHV; - maintenance and upgrading of the existing installations and equipment in our Institute; - participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and a AO plotter, what allows us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop can offer a wide range of machining and treatment methods with satisfactory tolerances and surface quality. It offers the following possibilities: - turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc-type elements of a diameter up to 600 mm and a length not exceeding 300 mm; - milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm; - grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm; - drilling - holes of a diameter up to 50 mm; - welding - electrical and gas welding, including TIG vacuum-tight welding; - soft and hard soldering; - mechanical works including precision engineering; - plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides; - painting - paint spraying with possibility of using furnace-fred drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop posses CNC milling machine which can be used for machining of work-pieces up to 500 kg

  17. Mining face equipment

    Energy Technology Data Exchange (ETDEWEB)

    G, Litvinskiy G; Babyuk, G V; Yakovenko, V A

    1981-01-07

    Mining face equipment includes drilling advance wells, drilling using explosives on the contour bore holes, loading and transporting the crushed mass, drilling reinforcement shafts, injecting reinforcement compounds and moving the timber. Camouflet explosives are used to form relaxed rock stress beyond the mining area to decrease costs of reinforcing the mining area by using nonstressed rock in the advance well as support. The strengthening solution is injected through advanced cementing wells before drilling the contour bores as well as through radial cementing wells beyond the timbers following loading and transport of the mining debris. The advance well is 50-80 m.

  18. Coal ash monitoring equipment

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C G; Wormald, M R

    1978-10-02

    The monitoring equipment is used to determine the remainder from combustion (ash slack) of coal in wagons designed for power stations. Next to the rails, a neutron source (252 Cf, 241 Am/Be) is situated, which irradiates the coal with neutrons at a known dose, which produces the reaction 27 Al (n ..gamma..) Al 28. The aluminium content is a measure of the remainder. The 1.78 MeV energy is measured downstream of the rail with a detector. The neutron source can only act in the working position of a loaded wagon.

  19. Management of Transportation Equipment.

    Science.gov (United States)

    1982-11-01

    Record% % %. "jP -M -. M LIh TRANSPORTATION MAENTKENAI4CE SHOP WORKLOAD CONTROL WORK CENTER SADR A-OR .a’* tLR 4.,R53 8114LM 0 o 251 50 75 100 125 ISO ...PDBP 06 7 4892 TRACTOR, WHEEL, INDUST, 14001-20000 PDBP 06 7 4893 TRACTOR, WHEEL, INDUST, 20001-27000 PDBP 06 7 4894 TRACTOR, WHEEL, INDUST, 27001 PDBP...27K TRACTOR, WHEEL, INDUST, 27001 PDBP & UP P-i LINE ITEM 07 LIGHTING AND POWER GENERATION EQUIPMENT 5110 T FLOODLIGHT ELEC FLOODLIGHT, ELEC, TRUCK

  20. Engineering aspects of a thermal control subsystem for the 25 kW power module

    Science.gov (United States)

    Schroeder, P. E.

    1979-01-01

    The paper presents the key trade study results, analysis results, and the recommended thermal control approach for the 25 kW power module defined by NASA. Power conversion inefficiencies and component heat dissipation results in a minimum heat rejection requirement of 9 kW to maintain the power module equipment at desired temperature levels. Additionally, some cooling capacity should be provided for user payloads in the sortie and free-flying modes. The baseline thermal control subsystem includes a dual-loop-pumped Freon-21 coolant with the heat rejected from deployable existing orbiter radiators. Thermal analysis included an assessment of spacecraft orientations, radiator shapes and locations, and comparison of hybrid heat pipe and all liquid panels.

  1. Justine user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.R.

    1995-10-01

    Justine is the graphical user interface to the Los Alamos Radiation Modeling Interactive Environment (LARAMIE). It provides LARAMIE customers with a powerful, robust, easy-to-use, WYSIWYG interface that facilitates geometry construction and problem specification. It is assumed that the reader is familiar with LARAMIE, and the transport codes available, i.e., MCNPTM and DANTSYSTM. No attempt is made in this manual to describe these codes in detail. Information about LARAMIE, DANTSYS, and MCNP are available elsewhere. It i also assumed that the reader is familiar with the Unix operating system and with Motif widgets and their look and feel. However, a brief description of Motif and how one interacts with it can be found in Appendix A.

  2. Californium-252 Program Equipment Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chattin, Fred Rhea [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wilson, Kenton [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ezold, Julie G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-12-01

    To successfully continue the 252Cf production and meet the needs of the customers, a comprehensive evaluation of the Building 7920 processing equipment was requested to identify equipment critical to the operational continuity of the program.

  3. Piping equipment; Materiel petrole

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This 'blue bible' of the perfect piping-man appeals to end-users of industrial facilities of the petroleum and chemical industries (purchase services, standardization, new works, maintenance) but also to pipe-makers and hollow-ware makers. It describes the characteristics of materials (carbon steels, stainless steels, alloyed steels, special alloys) and the dimensions of pipe elements: pipes, welding fittings, flanges, sealing products, forged steel fittings, forged steel valves, cast steel valves, ASTM standards, industrial valves. (J.S.)

  4. Study of National Electric System equipment until 2000 year

    International Nuclear Information System (INIS)

    1980-01-01

    The report by the German firm Lahmeyer International is about the historical development of the supply of Electric Power, description of the current system, previous studies, organization, power plants, hydroelectric plants and existing construction, transmission system, hydrological studies and water resources, operation of hydro thermal generation, medium-term demand, energy sources and generation in the medium term, list of thermal plants, evaluation of alternative equipment plans in Uruguay at a med dium term.

  5. Photovoltaics information user study

    Energy Technology Data Exchange (ETDEWEB)

    Belew, W.W.; Wood, B.L.; Marie, T.L.; Reinhardt, C.L.

    1980-10-01

    The results of a series of telephone interviews with groups of users of information on photovoltaics (PV) are described. These results, part of a larger study on many different solar technologies, identify types of information each group needed and the best ways to get information to each group. The report is 1 of 10 discussing study results. The overall study provides baseline data about information needs in the solar community. It covers these technological areas: photovoltaics, passive solar heating and cooling, active solar heating and cooling, biomass energy, solar thermal electric power, solar industrial and agricultural process heat, wind energy, ocean energy, and advanced energy storage. An earlier study identified the information user groups in the solar community and the priority (to accelerate solar energy commercialization) of getting information to each group. In the current study only high-priority groups were examined. Results from seven PV groups respondents are analyzed in this report: DOE-Funded Researchers, Non-DOE-Funded Researchers, Researchers Working for Manufacturers, Representatives of Other Manufacturers, Representatives of Utilities, Electric Power Engineers, and Educators.

  6. Characterization equipment essential drawing plan

    International Nuclear Information System (INIS)

    WILSON, G.W.

    1999-01-01

    The purpose of this document is to list the Characterization equipment drawings that are classified as Essential Drawings. Essential Drawings: Are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment (HNF 1997a). The Characterization equipment drawings identified in this report are deemed essential drawings as defined in HNF-PRO-242, Engineering Drawing Requirements (HNF 1997a). These drawings will be prepared, revised, and maintained per HNF-PRO-440, Engineering Document Change Control (HNF 1997b). All other Characterization equipment drawings not identified in this document will be considered Support drawings until the Characterization Equipment Drawing Evaluation Report is completed

  7. Coal mining equipment

    International Nuclear Information System (INIS)

    Stein, R.R.; Martin, T.W.

    1991-01-01

    The word in longwall components is big, and these larger components have price tags to match. The logic behind the greater investment is that it will yield high production rates and good uptime statistics. This is true in most cases. More important than single-shift tonnage records, average shift production continues to climb upwards. This paper reports on the quality, and more significantly, the quantity of service supplied for long-wall equipment, which has reached levels that would have been seen as unachievable when longwall mining was first introduced in the U.S. The school of thought then was that longwall would increase productivity in part by reducing the number of production units and thus reducing the number of personnel employed underground. The expectation of fewer employees turned out to be unrealistic. That was probably one reason that some early attempts to install longwall system looked more like failures than vision of the future

  8. Reactor fuel charging equipment

    International Nuclear Information System (INIS)

    Wade, Elman.

    1977-01-01

    In many types of reactor fuel charging equipment, tongs or a grab, attached to a trolley, housed in a guide duct, can be used for withdrawing from the core a selected spent fuel assembly or to place a new fuel assembly in the core. In these facilities, the trolley may have wheels that roll on rails in the guide duct. This ensures the correct alignment of the grab, the trolley and fuel assembly when this fuel assembly is being moved. By raising or lowering such a fuel assembly, the trolley can be immerged in the coolant bath of the reactor, whereas at other times it can be at a certain level above the upper surface of the coolant bath. The main object of the invention is to create a fuel handling apparatus for a sodium cooled reactor with bearings lubricated by the sodium coolant and in which the contamination of these bearings is prevented [fr

  9. Thermal Power:Focusing on Efficient and Clean Generation

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    History review Before the foundation of New China,there was no thermal power equipment manufacturing industry in China at all.China imported the manufacturing technology of 6-MW and12-MW thermal power units from the former

  10. Chapter 12. Space Heating Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Rafferty, Kevin D.

    1998-01-01

    The performance evaluation of space heating equipment for a geothermal application is generally considered from either of two perspectives: (a) selecting equipment for installation in new construction, or (b) evaluating the performance and retrofit requirements of an existing system. With regard to new construction, the procedure is relatively straightforward. Once the heating requirements are determined, the process need only involve the selection of appropriately sized hot water heating equipment based on the available water temperature. It is important to remember that space heating equipment for geothermal applications is the same equipment used in non-geothermal applications. What makes geothermal applications unique is that the equipment is generally applied at temperatures and flow rates that depart significantly from traditional heating system design. This chapter presents general considerations for the performance of heating equipment at non-standard temperature and flow conditions, retrofit of existing systems, and aspects of domestic hot water heating.

  11. Human Factors Evaluation of the Modular Lightweight Load-Carrying Equipment (MOLLE) System

    National Research Council Canada - National Science Library

    Sampson, James

    2001-01-01

    .... The FEA was used in drafting a new user requirements document and initiating the development of a modular load-carrying system which ultimately became known as the Modular Lightweight Load-carrying Equipment (MOLLE...

  12. Additional Equipment for Soil Biodegradation

    Science.gov (United States)

    Vondráčková, Terezie; Kraus, Michal; Šál, Jiří

    2017-12-01

    Intensification of industrial production, increasing citizens’ living standards, expanding the consumer assortment mean in the production - consumption cycle a constantly increasing occurrence of waste material, which by its very nature must be considered as a source of useful raw materials in all branches of human activity. In addition to strict legislative requirements, a number of circumstances characterize waste management. It is mainly extensive transport associated with the handling and storage of large volumes of substances with a large assortment of materials (substances of all possible physical and chemical properties) and high demands on reliability and time coordination of follow-up processes. Considerable differences in transport distances, a large number of sources, processors and customers, and not least seasonal fluctuations in waste and strong price pressures cannot be overlooked. This highlights the importance of logistics in waste management. Soils that are contaminated with oil and petroleum products are hazardous industrial waste. Methods of industrial waste disposal are landfilling, biological processes, thermal processes and physical and chemical methods. The paper focuses on the possibilities of degradation of oil pollution, in particular biodegradation by bacteria, which is relatively low-cost among technologies. It is necessary to win the fight with time so that no ground water is contaminated. We have developed two additional devices to help reduce oil accident of smaller ranges. In the case of such an oil accident, it is necessary to carry out the permeability test of contaminated soil in time and, on this basis, to choose the technology appropriate to the accident - either in-sit biodegradation - at the site of the accident, or on-sit - to remove the soil and biodegrade it on the designated deposits. A special injection drill was developed for in-sit biodegradation, tossing and aeration equipment of the extracted soil was developed for

  13. User Requirements for Wireless

    DEFF Research Database (Denmark)

    in the elicitation process. Cases and user requirement elements discussed in the book include: User requirements elicitation processes for children, construction workers, and farmers User requirements for personalized services of a broadcast company Variations in user involvement Practical elements of user...

  14. TDRSS S-shuttle unique receiver equipment

    Science.gov (United States)

    Weinberg, A.; Schwartz, J. J.; Spearing, R.

    1985-01-01

    Beginning with STS-9, the Tracking and Date Relay Satellite system (TDRSS) will start providing S- and Ku-band communications and tracking support to the Space Shuttle and its payloads. The most significant element of this support takes place at the TDRSS White Sands Ground Terminal, which processes the Shuttle return link S- and Ku-band signals. While Ku-band hardware available to other TDRSS users is also applied to Ku-Shuttle, stringent S-Shuttle link margins have precluded the application of the standard TDRSS S-band processing equipment to S-Shuttle. It was therfore found necessary to develop a unique S-Shuttle Receiver that embodies state-of-the-art digital technology and processing techniques. This receiver, developed by Motorola, Inc., enhances link margins by 1.5 dB relative to the standard S-band equipment and its bit error rate performance is within a few tenths of a dB of theory. An overview description of the Space Shuttle Receiver Equipment (SSRE) is presented which includes the presentation of block diagrams and salient design features. Selected, measured performance results are also presented.

  15. Decontamination and Decommissioning Equipment Tracking System (DDETS)

    International Nuclear Information System (INIS)

    Cook, S.

    1994-07-01

    At the request of the Department of Energy (DOE)(EM-50), the Scientific Computing Unit developed a prototype system to track information and data relevant to equipment and tooling removed during decontamination and decommissioning activities. The DDETS proof-of-concept tracking system utilizes a one-dimensional (1D) and two-dimensional (2D) bar coding technology to retain and track information such as identification number, manufacturer, requisition information, and various contaminant information, etc. The information is encoded in a bar code, printed on a label and can be attached to corresponding equipment. The DDETS was developed using a proven relational database management system which allows the addition, modification, printing, and deletion of data. In addition, communication interfaces with bar code printers and bar code readers were developed. Additional features of the system include: (a) Four different reports available for the user (REAPS, transaction, and two inventory), (b) Remote automated inventory tracking capabilities, (c) Remote automated inventory tracking capability (2D bar codes allow equipment to be scanned/tracked without being linked to the DDETS database), (d) Edit, update, delete, and query capabilities, (e) On-line bar code label printing utility (data from 2D bar codes can be scanned directly into the data base simplifying data entry), and (f) Automated data backup utility. Compatibility with the Reportable Excess Automated Property System (REAPS) to upload data from DDETS is planned

  16. Equipment repair in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, S

    1982-01-01

    Most equipment in Chinese coal mines consists of machinery and equipment produced in the 1950s; the efficiency of 4-62, CTD-57 and 70B/sub 2/ ventilators is 15% lower than that of new ones; that of SSM and AYaP pumps, 10% lower than of modern ones. Equipment renovation is done in three ways: replacing obsolete equipment with new equipment of the same type; improving the performance of existing equipment by introducing efficiency and reconstruction; and replacing obsolete equipment with advanced equipment. It is indicated that the second way, for example, replacement of 4-62 ventilator blades with a maximum efficiency of 73% by 4-72 ventilator blades raises its efficiency to 90%. Replacing the 8DA-8x3 water pump, having a maximum efficiency of 63%, with the 200D 43x3 pump with a maximum efficiency of 78%, enables an electricity savings of 7000 yuan per year, which exceeds all replacement costs (600 yuan). The need to improve equipment maintenance and preventive work to increase equipment service life and to introduce new techniques and efficiency is noted.

  17. Potentially damaging failure modes of high- and medium-voltage electrical equipment

    International Nuclear Information System (INIS)

    Hoy, H.C.

    1983-07-01

    The electrical equipment failures of both nuclear and nonnuclear public utilities were reviewed. Those failures that could pose an additional problem to surrounding and connected equipment were defined. The literature was searched; utilities, repair shops, and large electrical equipment users were contacted for failure information. The data were reviewed in detail, and failure modes were determined. Sample cascade failures are discussed. The failure rate of electrical equipment in utilities is historically quite low. Nuclear plants record too few failures to be statistically valid, but failures that have been recorded show that good design usually restricts the failure to a single piece of equipment

  18. Low-energy house in Sisimiut - Measurement equipment

    DEFF Research Database (Denmark)

    Andersen, Philip Hvidthøft Delff; Rode, Carsten; Madsen, Henrik

    on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented...

  19. 21 CFR 866.4540 - Immunonephelometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4540 Immunonephelometer equipment. (a) Identification. Immunonephelometer equipment for clinical use...

  20. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  1. Low-energy house in Sisimiut - Measurement equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hvidthoeft Delff Andersen, P.; Rode, C.; Madsen, Henrik

    2013-08-15

    This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. (Author)

  2. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  3. Generation of equipment response spectrum considering equipment-structure interaction

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Yoo, Kwang Hoon

    2005-01-01

    Floor response spectra for dynamic response of subsystem such as equipment, or piping in nuclear power plant are usually generated without considering dynamic interaction between main structure and subsystem. Since the dynamic structural response generally has the narrow-banded shapes, the resulting floor response spectra developed for various locations in the structure usually have high spectral peak amplitudes in the narrow frequency bands corresponding to the natural frequencies of the structural system. The application of such spectra for design of subsystems often leads to excessive design conservatisms, especially when the equipment frequency and structure are at resonance condition. Thus, in order to provide a rational and realistic design input for dynamic analysis and design of equipment, dynamic equipment-structure interaction (ESI) should be considered in developing equipment response spectrum which is particularly important for equipment at the resonance condition. Many analytical methods have been proposed in the past for developing equipment response spectra considering ESI. However, most of these methods have not been adapted to the practical applications because of either the complexities or the lack of rigorousness of the methods. At one hand, mass ratio among the equipment and structure was used as an important parameter to obtain equipment response spectra. Similarly, Tseng has also proposed the analytical method for developing equipment response spectra using mass ratio in the frequency domain. This method is analytically rigorous and can be easily validated. It is based on the dynamic substructuring method as applied to the dynamic soil-structure interaction (SSI) analysis, and can relatively easily be implemented for practical applications without to change the current dynamic analysis and design practice for subsystems. The equipment response spectra derived in this study are also based on Tseng's proposed method

  4. Overall Equipment Effectiveness Implementation Criteria

    Science.gov (United States)

    Abramova, I. G.; Abramov, D. A.

    2018-01-01

    This article documents the methods applied in production control technics specifically focused on commonly used parameter OEE (Overall Equipment Effectiveness). The indicators of extensive and intensive use of equipment are considered. Their appointment this is comparison in the same type of production within the industry and comparison of single-type and / or different types of equipment in terms of capacity. However, it is shown that there is no possibility of revealing the reasons for the machine’s operation: productive / unproductive, with disturbances. Therefore, in the article reveals the approaches to calculating the indicator characterizing the direct operation of the equipment. The Machine Load coefficient is approaching closely to the indicator of the efficiency of the use of equipment. Methods analysis is proceeded through the historically applied techniques such as “Stopwatch” and “Motion” studies. Was performed the analysis of the efficiency index of OEE equipment using the comparable indexes performance of equipment in the Russian practice. An important indicator of OEE contains three components. The meaning of each of them reflects historically applicable indicators. The value of the availability of equipment indicator is close to the value of the equipment extensibility index. The value of the indicator of the efficiency of work can be compared with the characteristic of the capacity of the equipment and the indicator of the quality level can meet the requirements for compliance with the manufacturing technology. Shown that the sum of the values of the coefficient of “Availability” of the equipment and the value of the “Factor of compaction of working hours” are one. As well as the total value of the indicator “level of quality” and the coefficient of marriage given in the result unit. The measurability of the indicators makes it possible to make a prediction about efficiency of the equipment.

  5. Perfil de los usuarios de drogas por vía parenteral que mantienen conductas de riesgo relacionadas con la inyección en Cataluña Characteristics of intravenous drug users who share injection equipment in Catalonia (Spain

    Directory of Open Access Journals (Sweden)

    Cinta Folch

    2012-02-01

    Full Text Available Objetivos: Estimar la prevalencia de las prácticas de riesgo directas e indirectas relacionadas con la inyección de drogas e identificar los factores asociados en los usuarios de drogas por vía parenteral (UDVP en centros de reducción de daños en Cataluña. Métodos: Estudio transversal realizado entre 2008 y 2009 en centros de reducción de daños. La información conductual se recogió mediante un cuestionario anónimo administrado por entrevistadores previamente formados. Resultados: De los 748 entrevistados, el 31,5% compartió jeringas usadas en los últimos 6 meses y el 55,2% compartió la cuchara, el agua o el filtro, o realizó el front/backloading con jeringas usadas. Los UDVP que se inyectan diariamente (odds ratio [OR]=1,5, se inyectan cocaína (OR=1,6, obtienen menos jeringas gratuitas (OR=2,5 menos de la mitad a ninguna, tienen una pareja sexual UDVP (OR=1,8 y comparten indirectamente (OR=4,1 presentaron una mayor probabilidad de haber compartido jeringas. Por otro lado, tener una fuente de ingresos ilegal (OR=1,5, inyectarse diariamente (OR=1, 5, inyectarse cocaína (OR=1,4, haber compartido jeringas (OR=3,9 y haber tenido alguna sobredosis en la vida (OR=1,5 fueron factores asociados a compartir de forma indirecta. Conclusiones: A pesar de la generalización de los programas de reducción de daños, en Cataluña se mantiene un porcentaje de UDVP que realizan conductas de riesgo relacionadas con la inyección. Sería necesario mejorar el acceso a todo el material estéril de inyección, en especial entre los que se inyectan cocaína y los que se inyectan con mayor frecuencia, e incluir también a las parejas sexuales UDVP en estas intervenciones preventivas.Objectives: To estimate the prevalence of direct and indirect syringe sharing among intravenous drug users (IDUs attending a harm reduction center in Catalonia (Spain and to identify factors associated with risk behaviors. Methods: A cross-sectional study was conducted

  6. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  7. Management methodology for pressure equipment

    Science.gov (United States)

    Bletchly, P. J.

    Pressure equipment constitutes a significant investment in capital and a major proportion of potential high-risk plant in many operations and this is particularly so in an alumina refinery. In many jurisdictions pressure equipment is also subject to statutory regulation that imposes obligations on Owners of the equipment with respect to workplace safety. Most modern technical standards and industry codes of practice employ a risk-based approach to support better decision making with respect to pressure equipment. For a management system to be effective it must demonstrate that risk is being managed within acceptable limits.

  8. Performance characterization of night vision equipment based on Triangle Orientation Discrimination (TOD) methodology

    NARCIS (Netherlands)

    Laurent, N.; Lejard, C.; Deltel, G.; Bijl, P.

    2013-01-01

    Night vision equipment is crucial in order to accomplish supremacy and safety of the troops on the battlefield. Evidently, system integrators, MODs and end-users need access to reliable quantitative characterization of the expected field performance when using night vision equipment. The Image

  9. Human-centered design of the human-system interfaces of medical equipment: thyroid uptake system

    International Nuclear Information System (INIS)

    Monteiro, Jonathan K.R.; Farias, Marcos S.; Santos, Isaac J.A. Luquetti; Monteiro, Beany G.

    2013-01-01

    Technology plays an important role in modern medical centers, making healthcare increasingly complex, relying on complex technical equipment. This technical complexity is particularly noticeable in the nuclear medicine. Poorly design human-system interfaces can increase the risks for human error. The human-centered approach emphasizes the development of the equipment with a deep understanding of the users activities, current work practices, needs and abilities of the users. An important concept of human-centered design is that the ease-of-use of the equipment can be ensured only if users are actively incorporated in all phases of the life cycle of design process. Representative groups of users are exposed to the equipment at various stages in development, in a variety of testing, evaluation and interviewing situations. The users feedback obtained is then used to refine the design, with the result serving as input to the next interaction of design process. The limits of the approach are that the users cannot address any particular future needs without prior experience or knowledge about the equipment operation. The aim of this paper is to present a methodological framework that contributes to the design of the human-system interfaces, through an approach related to the users and their activities. A case study is described in which the methodological framework is being applied in development of new human-system interfaces of the thyroid uptake system. (author)

  10. Cryogenic equipment; Materiel cryogenique

    Energy Technology Data Exchange (ETDEWEB)

    Leger, L; Javellaud, J; Caro, C; Gilguy, R; Testard, O

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [French] De nombreuses experiences utilisant les basses temperatures, necessitent l'emploi d'un materiel cryogenique complexe n'existant pas dans le commerce. Les cryostats presentes ici ont ete realises a partir d'elements standard, ce qui permet, malgre la diversite des appareils, de realiser un ensemble a moindre frais. Les reservoirs d'azote et d'helium liquides ont ete concus de facon a limiter les pertes et a conferer au cryostat la plus grande autonomie possible. L'enceinte experimentale situee en general dans la partie inferieure de l'appareil necessite dans tous les cas une etude speciale. D'autre part des ensembles complets tels que les cannes de transfert, piege isole, robinet pour vide secondaire, ont ete concus dans le meme souci de rentabilite et de standardisation. Ce materiel peut donc repondre a un grand nombre d'exigences experimentales, il est facilement adaptable, et les consommations d'helium et d'azote liquide sont tres reduites. (auteurs)

  11. University multi-user facility survey-2010.

    Science.gov (United States)

    Riley, Melissa B

    2011-12-01

    Multi-user facilities serve as a resource for many universities. In 2010, a survey was conducted investigating possible changes and successful characteristics of multi-user facilities, as well as identifying problems in facilities. Over 300 surveys were e-mailed to persons identified from university websites as being involved with multi-user facilities. Complete responses were received from 36 facilities with an average of 20 years of operation. Facilities were associated with specific departments (22%), colleges (22%), and university research centers (8.3%) or were not affiliated with any department or college within the university (47%). The five most important factors to succeed as a multi-user facility were: 1) maintaining an experienced, professional staff in an open atmosphere; 2) university-level support providing partial funding; 3) broad client base; 4) instrument training programs; and 5) an effective leader and engaged strategic advisory group. The most significant problems were: 1) inadequate university financial support and commitment; 2) problems recovering full service costs from university subsidies and user fees; 3) availability of funds to repair and upgrade equipment; 4) inability to retain highly qualified staff; and 5) unqualified users dirtying/damaging equipment. Further information related to these issues and to fee structure was solicited. Overall, there appeared to be a decline in university support for facilities and more emphasis on securing income by serving clients outside of the institution and by obtaining grants from entities outside of the university.

  12. Code of Practice for Protection Against Ionizing Radiation Emitted from X-ray Analysis Equipment (1984)

    International Nuclear Information System (INIS)

    1984-01-01

    Appropriate working rules, safety features and monitoring requirements for general X-ray analysis units or equipment are laid down in this Code which is intended for users of such equipment. The Code advises that establishments draw up their own working procedures based on appropriate legislation and on the recommendations contained in this Code. The Code also describes the requirements for X-ray analysis equipment necessary to ensure safety. (NEA) [fr

  13. The Thermal Evaluation of Air-Cooled Electronic Equipment

    Science.gov (United States)

    1952-09-01

    Temperatures 22 5. Primary Thermometric Elements. Thermocouples 23 6. Instruments for Thermocouples 30 7. Checking for Operation within Specified...from the outer container wall to the atmosphere of the room. For the con- struction of the inner container, polished aluminum is desirable so as to... aluminum , is to prevent radiant heat transfer from the component to be tested so that cooling can only occur by free convection. Thus, the most

  14. Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea

    International Nuclear Information System (INIS)

    Ham, J. K.; Lee, D. H.; Park, J. W.; Jeong, M. H.; Choi, Y. H.; Suh, J. J.; Jang, T. H.

    2007-06-01

    Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products

  15. Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J. K.; Lee, D. H.; Park, J. W.; Jeong, M. H.; Choi, Y. H.; Suh, J. J.; Jang, T. H. [Korea Testing Laboratory, Seoul (Korea, Republic of)

    2007-06-15

    Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products.

  16. RELAP4/MOD5: a computer program for transient thermal-hydraulic analysis of nuclear reactors and related systems. User's manual. Supplement 1, RELAP4/MOD5, Update 2

    International Nuclear Information System (INIS)

    Bruch, C.G.

    1976-08-01

    RELAP4/MOD5, Update 1 was released to the Nuclear Regulatory Commission in January 1976. Six months of extensive use of Update 1 has led to the identification and correction of a number of errors in the code, as well as some logic changes, additional Evaluation Model (EM) checks, and one model revision. These changes have culminated in the release of an improved code identified as RELAP4/MOD5, Update 2. The RELAP4/MOD5 interim User's Manual (Interim Report SRD-113-76) reflected the Update 1 version of the code. The purpose of the supplement presented is to update the Interim User's Manual for use with RELAP4/MOD5, Update 2. Major differences between Updates 1 and 2 and the checkout of Update 2 are discussed. The final version of the User's Manual will be written in accordance with Update 2 and will be published as ANCR-NUREG 1335 during September 1976. Annotation of the existing three volumes of the User's Manual to cross-reference this Supplement is recommended

  17. SIMone user's manual. V. 2.1

    International Nuclear Information System (INIS)

    Silk, M.

    1990-03-01

    Simone is a computer application program which provides an environment in which to run the nuclear reactor thermal hydraulic simulation code RELAP5. It enables users to run a RELAP5 calculation on-line on a SUN4 workstation, and provides an interactive means of executing operator-like actions. In addition, a version of the graphical post-processing tool ISOVU is incorporated, allowing a real-time display of the RELAP5 calculation to be presented in the form of a system mimic diagram. This report comprises a description of the facilities available within the Simone application, and a user guide describing the user interface. (author)

  18. 29 CFR 1926.952 - Mechanical equipment.

    Science.gov (United States)

    2010-07-01

    ... equipment that are not covered with insulating protective equipment. (c) Derrick trucks, cranes and other lifting equipment. (1) All derrick trucks, cranes and other lifting equipment shall comply with subpart N...

  19. 22 CFR 135.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  20. 21 CFR 1403.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  1. 45 CFR 602.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  2. 49 CFR 18.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  3. 34 CFR 80.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  4. 10 CFR 600.232 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  5. 45 CFR 1183.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... specifically permitted or contemplated by Federal statute. (4) When acquiring replacement equipment, the...) Management requirements. Procedures for managing equipment (including replacement equipment), whether... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no...

  6. Buyers guide of industrial furnaces and heating equipment. Bau und Ausruestung von Industrieoefen und industriellen Waermeanlagen: Bezugsquellenverzeichnis

    Energy Technology Data Exchange (ETDEWEB)

    Stepanek, J [comp.

    1988-01-01

    The book is a glossary as well as a dictionary (German, English, French, Spanish). It comprises the following chapters: 1. Trade directory. 2. Industrial furnaces and industrial heating equipment. 3. Index to thermal processes. 4. Index to industrial furnaces and industrial heating equipment. 5. General accessories. 6. Special accessories. 7. Accessories for firing equipment. 8. Addresses. 9. Codes of practice. (HW).

  7. Laser alignment of rotating equipment at PNL

    International Nuclear Information System (INIS)

    Berndt, R.H.

    1994-05-01

    Lateral vibration in direct-drive equipment is usually caused by misalignment. Over the years, because of the need to improve on techniques and ways of working more efficiently, various types of alignment methods have evolved. In the beginning, craftsmen used a straight-edge scale across the coupling with a feeler gauge measuring the misalignment error. This is still preferred today for aligning small couplings. The industry has since decided that alignment of large direct-drive equipment needed a more accurate type of instrumentation. Rim and face is another of the first alignment methods and is used on all sizes of equipment. A disadvantage of the rim and face method is that in most cases the coupling has to be disassembled. This can cause alignment problems when the coupling is reassembled. Also, the rim and face method is not fast enough to work satisfactorily on alignment of thermally hot equipment. Another concern is that the coupling has to be manufactured accurately for correct rim and face readings. Reverse dial alignment is an improvement over the rim and face method, and depending on the operator's experience, this method can be very accurate. A good training program along with field experience will bring the operator to a proper level of proficiency for a successful program. A hand-held computer with reverse dial calculations in memory is a must for job efficiency. An advantage over the rim and face method is that the coupling is not disassembled and remains locked together. Reverse dial instrumentation measures from both shaft center lines, rather than the coupling surface so the machining of the coupling during manufacture is not a major concern

  8. Homemade Equipment for the Teaching of Electrochemistry at Advanced Level: Part III.

    Science.gov (United States)

    Chan, K. M.

    1985-01-01

    Describes: (1) thermometric titrations; (2) EM-5 equipment (consisting of a thermal sensor, calorimeter, and input-buffered amplifier); (3) acid-base titrations; (4) precipitation titrations; and (5) redox titrations. Detailed procedures are included. (JN)

  9. Food Service Equipment and Appurtenances.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    Equipment design specifications are presented relating to tables of all kinds, counters, sinks and drainboards, bins, shelves, drawers, hoods and similar kitchen appurtenances, not including baking, roasting, toasting, broiling or frying equipment, food preparation machinery such as slicers, choppers, and cutters, mixers and grinders, steam…

  10. Equipe de trabalho

    Directory of Open Access Journals (Sweden)

    Gabriel Gerber Hornink

    2014-08-01

    Full Text Available   Equipe de Trabalho 2014 1. Equipe editorial Editor-Chefe Bayardo Bapstista Torres, Instituto de Química - USP, Brasil Eduardo Galembeck, Departamento de Bioquímica Instituto de Biologia UNICAMP, Brasil   Editores Gabriel Gerber Hornink, Depto. Bioquímica, Instituto de Ciências Biomédicas, Universidade - Federal de Alfenas - Unifal-MG, Brasil Vera Maria Treis Trindade, Instituto de Ciências Básicas da Saúde, Departamento de Bioquímica, Universidade Federal do Rio Grande do Sul, Brasil   Corpo Editorial Adriana Cassina, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Angel Herráez, Departamento de Bioquímica y Biología molecular, Universidad de Alcalá de Henares, Madrid, Espanha André Amaral Gonçalves Bianco, Universidade Federal de São Paulo (Unifesp, Brasil Denise Vaz de Macedo, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Eneida de Paula, Departamento de Bioquímica, Instituto de Biologia, Universidade Estadual de Campinas - Unicamp, Brasil Guilherme Andrade Marson, Instituto de Química - USP, Brasil Jose Antonio Martinez Oyanedel, Universidad de Concepción, Chile Josep Maria Fernández Novell, Dept. Bioquímica i Biologia Molecular Universitat de Barcelona, Espanha Leila Maria Beltramini, Instituto de Física de São Carlos, Universidade Estadual de São Paulo - USP, Brasil Manuel João da Costa, Escola de Ciências da Saúde, Universidade do Minho, Portugal Maria Lucia Bianconi, Instituto de Bioquímica Médica Universidade Federal do Rio de Janeiro (UFRJ, Brasil María Noel Alvarez, Departamento de Bioquímica, Facultad de Medicina, Universidad de la República, Uruguai Miguel Ángel Medina Torres, Department of Molecular Biology & Biochemistry Faculty of Sciences University of Málaga, Espanha Nelma Regina Segnini Bossolan, Instituto de Física de São Carlos, Universidade de São Paulo - USP, Brasil Paulo De Avila

  11. Information technology equipment cooling method

    Science.gov (United States)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  12. Oil-field equipment in Romania. Export trade information

    International Nuclear Information System (INIS)

    Tinis, R.

    1991-09-01

    The Industry Sector Analyses (I.S.A.) for oil field equipment contains statistical and narrative information on projected market demand, end-users, receptivity of Romanian consumers to U.S. products, the competitive situation - Romanian production, total import market, U.S. market position, foreign competition, and competitive factors, and market access - Romanian tariffs, non-tariff barriers, standards, taxes and distribution channels. The I.S.A. provides the United States industry with meaningful information regarding the Romanian market for oil field equipment

  13. Thermo Techno Modern Analytical Equipment for Research and Industrial Laboratories

    Directory of Open Access Journals (Sweden)

    Khokhlov, S.V.

    2014-03-01

    Full Text Available A brief overview of some models of Thermo Techno analytical equipment and possible areas of their application is given. Thermo Techno Company was created in 2000 as a part of representative office of international corporation Thermo Fisher Scientific — world leader in manufacturing analytical equipments. Thermo Techno is a unique company in its integrated approach in solving the problems of the user, which includes a series of steps: setting the analytical task, selection of effective analysis methods, sample delivery and preparation as well as data transmitting and archiving.

  14. Problems of radiation protection at medical use of radiation equipment

    International Nuclear Information System (INIS)

    Larwin, K.

    1979-01-01

    For medical use of radiation equipment man is not only operator, but also object (patient). The question, if or how much it is necessary to expose the patient, is a medical problem and therefore not to be discussed here. For the user of medical equipments we have often special conditions. For many diagnostic applications the physician has to stay in the application room in contact with the patient. As a typical example for the problems of radiation protection there is discussed the situation on a well known fluoroscopic unit for lung and stomach examinations. (author)

  15. User Innovation Management

    DEFF Research Database (Denmark)

    Kanstrup, Anne Marie; Bertelsen, Pernille

    User Innovation Management (UIM) is a method for fo-opereation with users in innovation projects. The UIM method emphasizes the practice of a participatorty attitude.......User Innovation Management (UIM) is a method for fo-opereation with users in innovation projects. The UIM method emphasizes the practice of a participatorty attitude....

  16. User Behavior Analytics

    Energy Technology Data Exchange (ETDEWEB)

    Turcotte, Melissa [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Moore, Juston Shane [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-28

    User Behaviour Analytics is the tracking, collecting and assessing of user data and activities. The goal is to detect misuse of user credentials by developing models for the normal behaviour of user credentials within a computer network and detect outliers with respect to their baseline.

  17. Lazy User Behaviour

    OpenAIRE

    Collan, Mikael

    2007-01-01

    In this position paper we suggest that a user will most often choose the solution (device) that will fulfill her (information) needs with the least effort. We call this “lazy user behavior”. We suggest that the principle components responsible for solution selection are the user need and the user state. User need is the user’s detailed (information) need (urgency, type, depth, etc.) and user state is the situation, in which the user is at the moment of the need (location, time, etc.); the use...

  18. Standard Guide for Specifying Thermal Performance of Geothermal Power Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This guide covers power plant performance terms and criteria for use in evaluation and comparison of geothermal energy conversion and power generation systems. The special nature of these geothermal systems makes performance criteria commonly used to evaluate conventional fossil fuel-fired systems of limited value. This guide identifies the limitations of the less useful criteria and defines an equitable basis for measuring the quality of differing thermal cycles and plant equipment for geothermal resources. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Thermal imaging in medicine

    Directory of Open Access Journals (Sweden)

    Jaka Ogorevc

    2015-12-01

    be widely used also in the field of medicine. Implementation of every new technology in a daily clinical practice requires large number of measurements with such equipment compared by reference method for the purpose of clinical validation. The knowledge of measurement problematics is crucial. Collaboration between physicians and engineers on multi- and interdisciplinary level is of high importance for thermal imaging to win confidence of physicians and to gain reliability as a clinical diagnostic tool.

  20. Assessment of electrical equipment aging for nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The electrical and instrumentation equipments, especially whose parts are made of polymer material, are gradually degraded by thermal and radiation environment in the normal operation, and the degradation is thought to progress rapidly when they are exposed to the environment of the design basis event (DBE). The integrity of the equipments is evaluated by the environmental qualification (EQ) test simulating the environment of the normal operation and the DBE. The project of 'Assessment of Cable Aging for Nuclear Power Plants' (ACA, 2002-2008) indicated the importance of applying simultaneous thermal and radiation aging for simulating the aging in normal operation. The project of 'Assessment of Electrical Equipment Aging for Nuclear Power Plants' (AEA) was initiated in FY2008 to apply the outcome of ACA to the other electrical and instrumentation equipment and to establish an advanced EQ test method that can appropriately simulate the environment in actual plants. In FY2012, aging characteristics of thermal aging and simultaneous aging were obtained for the epoxy resin of electrical penetrations and the O-ring of connectors. Physical property measurement was carried out for epoxy resin of electrical penetration subject to the type testing in FY2010. (author)

  1. Assessment of electrical equipment aging for nuclear power plant

    International Nuclear Information System (INIS)

    2013-01-01

    The electrical and instrumentation equipments, especially whose parts are made of polymer material, are gradually degraded by thermal and radiation environment in the normal operation, and the degradation is thought to progress rapidly when they are exposed to the environment of the design basis event (DBE). The integrity of the equipments is evaluated by the environmental qualification (EQ) test simulating the environment of the normal operation and the DBE. The project of 'Assessment of Cable Aging for Nuclear Power Plants' (ACA, 2002-2008) indicated the importance of applying simultaneous thermal and radiation aging for simulating the aging in normal operation. The project of 'Assessment of Electrical Equipment Aging for Nuclear Power Plants' (AEA) was initiated in FY2008 to apply the outcome of ACA to the other electrical and instrumentation equipment and to establish an advanced EQ test method that can appropriately simulate the environment in actual plants. In FY2012, aging characteristics of thermal aging and simultaneous aging were obtained for the epoxy resin of electrical penetrations and the O-ring of connectors. Physical property measurement was carried out for epoxy resin of electrical penetration subject to the type testing in FY2010. (author)

  2. 40 CFR 63.2994 - How do I verify the performance of monitoring equipment?

    Science.gov (United States)

    2010-07-01

    ... equipment? (a) Before conducting the performance test, you must take the steps listed in paragraphs (a)(1) and (2) of this section: (1) Install and calibrate all process equipment, control devices, and... evaluation results. (b) If you use a thermal oxidizer, the temperature monitoring device must meet the...

  3. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  4. Imaging Sensor Flight and Test Equipment Software

    Science.gov (United States)

    Freestone, Kathleen; Simeone, Louis; Robertson, Byran; Frankford, Maytha; Trice, David; Wallace, Kevin; Wilkerson, DeLisa

    2007-01-01

    The Lightning Imaging Sensor (LIS) is one of the components onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, and was designed to detect and locate lightning over the tropics. The LIS flight code was developed to run on a single onboard digital signal processor, and has operated the LIS instrument since 1997 when the TRMM satellite was launched. The software provides controller functions to the LIS Real-Time Event Processor (RTEP) and onboard heaters, collects the lightning event data from the RTEP, compresses and formats the data for downlink to the satellite, collects housekeeping data and formats the data for downlink to the satellite, provides command processing and interface to the spacecraft communications and data bus, and provides watchdog functions for error detection. The Special Test Equipment (STE) software was designed to operate specific test equipment used to support the LIS hardware through development, calibration, qualification, and integration with the TRMM spacecraft. The STE software provides the capability to control instrument activation, commanding (including both data formatting and user interfacing), data collection, decompression, and display and image simulation. The LIS STE code was developed for the DOS operating system in the C programming language. Because of the many unique data formats implemented by the flight instrument, the STE software was required to comprehend the same formats, and translate them for the test operator. The hardware interfaces to the LIS instrument using both commercial and custom computer boards, requiring that the STE code integrate this variety into a working system. In addition, the requirement to provide RTEP test capability dictated the need to provide simulations of background image data with short-duration lightning transients superimposed. This led to the development of unique code used to control the location, intensity, and variation above background for simulated lightning strikes

  5. DEVELOPMENT OF COMPLEX EQUIPMENT FOR PLASMA SPRAY CERAMIC COATINGS

    Directory of Open Access Journals (Sweden)

    V. V. Okovity

    2017-01-01

    Full Text Available Develop a set equipment for plasma forming ceramic coatings. The article presents characteristics and parameters of the developed complex equipment for formation of plasma ceramic coatings as well as results of its testing. Methods of research is based on studies of structural elements composite plasma coatings system ZrO2 – Y2O3  obtained  using  developed complex equipment. One of the most effective ways to protect the components from high temperature corrosion and oxidation is formation on the surface of plasma thermal barrier coatings. For thermal barrier coating has very strict requirements: сharacterized by a smooth change of physico-mechanical properties (porosity, microhardness, elastic modulus in the cross section of the metal substrate to the outer ceramic layer; to withstand multiple cycles of thermal cycling from room temperature to the operating temperature; to maintain gastightness under operating conditions and thus ensure a sufficiently high level of adhesive strength. For realization of new technological schemes applying thermal barrier coatings with high operational characteristics was developed, patented and manufactured a range of new equipment. The experiments show that authors developed PBG-1 plasmatron and powder feeder PPBG-04 have at least 2–3 times the service life during the deposition of ceramic materials compared to the standard equipment of the company "Plasma-Technik", by changing the structure of the cathode-anode plasma torch assembly and construction of the delivery unit of the feeder to facilitate the uniform supply of the powder into the plasma jet and the best of his penetration. The result is better plasma coatings with improved operational characteristics: adhesion strength is increased to 1.3–2 times, material utilization in 1.5–1.6 times microhardness 1.2–1.4 times the porosity is reduced by 2–2.5 times.

  6. TRANSPORT AND EMPLACEMENT EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    1997-01-01

    The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) Transport and Emplacement in the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. The Transport and Emplacement equipment described in this document consists of the following: (1) WP Transporter; (2) Reusable Rail Car; (3) Emplacement Gantry; (4) Gantry Carrier; and (5) Transport Locomotive

  7. Containment and Surveillance Equipment Compendium

    International Nuclear Information System (INIS)

    Luetters, F.O.

    1980-02-01

    The Containment and Surveillance Equipment Compendium contains information sections describing the application and status of seals, optical surveillance systems, and monitors for international safeguards systems. The Compendium is a collection of information on equipment in use (generally by the IAEA) or under development in the US in diverse programs being conducted at numerous facilities under different sponsors. The Compendium establishes a baseline for the status and applications of C/S equipment and is a tool to assist in the planning of future C/S hardware development activities. The Appendix contains design concepts which can be developed to meet future goals

  8. Graphical user interfaces and visually disabled users

    NARCIS (Netherlands)

    Poll, L.H.D.; Waterham, R.P.

    1995-01-01

    From February 1992 until the end of 1993, the authors ((IPO) Institute for Perception Research) participated in a European ((TIDE) Technology Initiative for Disabled and Elderly) project which addressed the problem arising for visually disabled computer-users from the growing use of Graphical User

  9. Equipment and techniques developed for the repair of reactor standpipes

    International Nuclear Information System (INIS)

    Hartnell, P.; Kirton-Darling, H.F.R.; Walton, D.N.

    1993-01-01

    In-service cracks had developed in welds in the fabrication at the bottom of the standpipe liner at Hinkley Point-B and Hunterston-B reactors. A joint team investigating these cracks determined that the hot gas flow patterns in the plug unit to standpipe liner annulus were unstable. This had led to thermal stressing and consequent cracking of the standpipe liner welds. In developing a solution consideration was to be given to access down the standpipe for equipment, ambient temperatures, radiation levels and safety considerations. The procedures and equipment developed are described. (author)

  10. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to an equipment rack controller on the equipment rack. The equipment rack controllers link to a central control computer that provides an operator ...

  11. Thermal comfort

    CSIR Research Space (South Africa)

    Osburn, L

    2010-01-01

    Full Text Available Thermal comfort is influenced by environmental parameters as well as other influences including asymmetric heating and cooling conditions. Additionally, some aspects of thermal comfort may be exploited so as to enable a building to operate within a...

  12. [Legionella pneumonia after the use of CPAP equipment].

    Science.gov (United States)

    Stolk, Jaap M; Russcher, Anne; van Elzakker, Erika P M; Schippers, Emile F

    2016-01-01

    Continuous positive airway pressure (CPAP) equipment can be colonised by Legionellae and might cause Legionella pneumonia in the user. However, there is no reported case of Legionella pneumonia related to CPAP equipment in which an identical Legionella was found in both the patient and the CPAP equipment. A 51-year-old man came to the Emergency Department with fever, confusion and dyspnoea that had been present for 3 days. His medical history included obstructive sleep apnoea, for which he had been using CPAP therapy at home for 10 weeks. The CPAP equipment showed signs of poor maintenance. Chest X-ray revealed a pulmonary consolidation. Laboratory investigation resulted in a positive urine antigen test for Legionella. Water from the CPAP equipment and sputum from the patient revealed Legionella pneumophila. Serotyping and sequence-based typing showed an identical L. pneumophila serotype 1 ST37. It is important to be aware that CPAP equipment can be colonised with Legionellae and might cause Legionella pneumonia. It is therefore necessary to ask about CPAP therapy in a patient with community-acquired pneumonia.

  13. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  14. ENERGY STAR Certified Imaging Equipment

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Imaging Equipment that are effective as of...

  15. EMR Measurements on NDA Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Macdonell, Alexander Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Meierbachtol, Krista Cruse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Evans, James Walter Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Mayo, Douglas R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-10

    Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

  16. Mongolia - Vocational Education - Equipment Upgrades

    Data.gov (United States)

    Millennium Challenge Corporation — Evaluation design The impact evaluation sought to identify the causal impact of exposure to equipment upgrades on subsequent outcomes. Insofar as we were not able to...

  17. Operation monitor for plant equipment

    International Nuclear Information System (INIS)

    Kondo, Tetsufumi; Kanemoto, Shigeru.

    1991-01-01

    In a nuclear power plant, states of each of equipment in the plant are monitored accurately even under such a operation condition that the power is changed. That is, the fundamental idea is based on a model comparison method. A deviation between an output signal upon normal plant state obtained in a forecasting model device and that of the objective equipment in the plant are compared with a predetermined value. The result of the comparison is inputted to an alarm device to alarm the abnormality of the states of the equipment to an operator. The device of the present invention thus constituted can monitor the abnormality of the operation of equipment accurately even under such a condition that a power level fluctuates. As a result, it can remarkably contribute to mitigate operator's monitoring operation under the condition such as during load following operation. (I.S.)

  18. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    Science.gov (United States)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  19. Equipment improvements for performance enhancement

    International Nuclear Information System (INIS)

    Gaestel, P.; Guesnon, H.; Sauze, G.

    1994-01-01

    In order to enhance the reactor availability, several improvements on reactor equipment have been developed: design optimization for stator maintenance replacement in the main alternator; adjustment modification of stator coils in the main alternator for an easier maintenance; improvement of the fuel handling line (pole crane, transfer equipment, loading machine); development of a loose part trapping system in the steam generator secondary circuit. 1 tab

  20. Low level photoneutron detection equipment

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Yuqin; Li Yuansui

    1991-01-01

    A low level photoneutron detection equipment has been developed. The photoneutrons produced by interaction of 226 Ra gamma quanta and deutron (D) target are detected with n-n discrimination detector made up of 3 He proportional counter array. The D-content information in the target can be obtained from the measured photoneutron counts. The equipment developed is mainly used for nondestructive D-content measurement of D-devices

  1. FUSRAP equipment concept development study

    International Nuclear Information System (INIS)

    Hinerman, K.B.; Smith, R.E.

    1981-01-01

    Under DOE contract, Dalton-Dalton-Newport, Inc. is performing an engineering evaluation of three selected FUSRAP sites in an effort to generate equipment concepts to perform remedial action for retrieval, packaging, storing, and transporting contaminated soil and other debris. Along with this engineering evaluation, an analysis of state and Federal regulations was made which had significant impact on the selected equipment and costs for each remedial action concept

  2. Remotely operated replaceable process equipment

    International Nuclear Information System (INIS)

    Westendorf, H.

    1987-01-01

    The coupling process of pneumatic and electrical auxiliary lines of a pneumatic control pressure line in a large cell of the reprocessing plant is carried out, together with the coupling process of the connecting flange of the process equipment. The coupling places of the auxiliary lines, such as control or supply lines, are laid in the flange parts of the flanges to be connected. The pipe flange on the frame side remains flush with the connecting flange of the process equipment. (DG) [de

  3. Partners in qualified equipment supply

    International Nuclear Information System (INIS)

    Rygg, D.E.; O'Hare, G.J.

    1993-01-01

    Industry initiatives have been taken to improve procurement practices and commercial dedication programs, formation of procurement engineering groups, emphasis on product quality, and increased engineering involvement in procurement and maintenance of qualified equipment. This poses new challenges for many licensees in terms of resources, product knowledge, and access to information normally held proprietary by equipment suppliers. Alternative approaches to future licensee/Westinghouse relationships which will allow licensees to adapt to the changing environment are discussed. 2 figs

  4. Accelerator facilities users' guide

    International Nuclear Information System (INIS)

    Walter, H.C.; Adrion, L.; Frosch, R.; Salzmann, M.

    1994-07-01

    In 1981 the ''Green Book'' of SIN was distributed, a User Handbook serving the needs of people already working at SIN as well as informing new users about our installations. An update of the Green Book is necessary because many beams have disappeared, been modified or added, and the installation has been upgraded in intensity and versatility quite considerably. The spectrum of users has shifted away from nuclear and particle physics; applications in medicine, solid state physics and materials science have gained in importance. This Users' Guide is intended to inform our users about the changes, and to interest potential new users in coming to PSI. (author) figs., tabs

  5. Guideline for design and construction radiation monitoring equipments for Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Miyabe, Kenjiro; Ninomiya, Kazushige; Jin, Kazumi; Morifuji, Masayuki; Nemoto, Kazuhiko; Sato, Akira; Kawai, Keiichi

    1999-12-01

    Various kind of radiation monitoring equipment are used in radiation controlled area at each facility of Tokai reprocessing plant. These equipments have been designed and constructed based on the users requirements, and permitted by governmental regulation office. And, design has been carried out in consideration of the adoption of the new technology and our operational experience. Then, it has been used effectively for the radiation control of the facilities. This report summarizes the technical requirements that should be taken into consideration in the design and installation of radiation monitoring equipments. These requirements are fundamentally applicable when the equipments of the new facilities will be designed or the present instruments will be replaced. (author)

  6. Maintenance of electronic equipment at the Saclay Nuclear Research Centre

    International Nuclear Information System (INIS)

    Chicheportiche, Armand; Raoult, Norbert.

    1975-06-01

    The Test-Repair Group of the Saclay Electronics Services ensures the maintenance of electronic equipment available to users of the Saclay site. The more and more frequent use of microelectronics in these instruments increases the electronic operator density and the working and data transmission sequences are becoming difficult to understand. This leads to complications in the adjustment, testing and repairs. Ways and means are studied to facilitate maintenance while reducing the immobilization time of the equipment and the repair costs. The Saclay Electronics Services have developed a method of systematic test sequence formulation and breakdown diagnosis based on the properties of binary analysis. This method is used by a supplier of the CEA which has built the corresponding test equipment. Owing to the test programmmes established for each component of an apparatus it is possible for example to locate a faulty element on a plan including more than 100 integrated circuits and to replace it in no more than 10 minutes [fr

  7. Thermal Testing Measurements Report

    Energy Technology Data Exchange (ETDEWEB)

    R. Wagner

    2002-09-26

    The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure

  8. User interface user's guide for HYPGEN

    Science.gov (United States)

    Chiu, Ing-Tsau

    1992-01-01

    The user interface (UI) of HYPGEN is developed using Panel Library to shorten the learning curve for new users and provide easier ways to run HYPGEN for casual users as well as for advanced users. Menus, buttons, sliders, and type-in fields are used extensively in UI to allow users to point and click with a mouse to choose various available options or to change values of parameters. On-line help is provided to give users information on using UI without consulting the manual. Default values are set for most parameters and boundary conditions are determined by UI to further reduce the effort needed to run HYPGEN; however, users are free to make any changes and save it in a file for later use. A hook to PLOT3D is built in to allow graphics manipulation. The viewpoint and min/max box for PLOT3D windows are computed by UI and saved in a PLOT3D journal file. For large grids which take a long time to generate on workstations, the grid generator (HYPGEN) can be run on faster computers such as Crays, while UI stays at the workstation.

  9. 29 CFR 97.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  10. 44 CFR 13.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  11. 24 CFR 85.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  12. 41 CFR 105-71.132 - Equipment.

    Science.gov (United States)

    2010-07-01

    .... (4) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be... managing equipment (including replacement equipment), whether acquired in whole or in part with grant funds... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Equipment. 105-71.132...

  13. 43 CFR 12.72 - Equipment.

    Science.gov (United States)

    2010-10-01

    ...) When acquiring replacement equipment, the grantee or subgrantee may use the equipment to be replaced as... equipment (including replacement equipment), whether acquired in whole or in part with grant funds, until... established to ensure the highest possible return. (e) Disposition. When original or replacement equipment...

  14. 1968 Listing of Swimming Pool Equipment.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI. Testing Lab.

    An up-to-date listing of swimming pool equipment including--(1) companies authorized to display the National Sanitation Foundation seal of approval, (2) equipment listed as meeting NSF swimming pool equipment standards relating to diatomite type filters, (3) equipment listed as meeting NSF swimming pool equipment standard relating to sand type…

  15. Scientific and Practical Commentary on Specialists’ Professional Standards in Thermal

    Directory of Open Access Journals (Sweden)

    M. Yu. Semenov

    2016-01-01

    Full Text Available The professional standards for heat treatment specialists such as "Specialist in thermal equipment installation and tests", "Specialist in analysis and diagnosis of heat treatment process systems", "Specialist in automation and mechanization of heat treatment process systems" were developed according to the Rules for the Development, Approval, and Application of Professional Standards adopted by a Decree of the Government of the Russian Federation dated 01.22.2013 № 23.The article objective is to find a way that allows directors of machine-building plants to understand the provisions of abovementioned professional standards.This commentary was developed with participation of experts, who were in charge of the professional standards.When developing the professional standards it was taken into consideration that, presently, the most promising are vacuum and ion processes of heat and thermo-chemical treatment.In this connection a new classification of the thermal equipment and manufacturing processes has been realized according to criterion of technical complexity. This classification puts the thermal equipment and manufacturing processes into simple, complex, and specifically complex.As proposed, the specifically complex thermal equipment is a multi-zone thermal one with each zone being under precise temperature control, and a vacuum or ion equipment for thermal and thermochemical treatment with integrated cooling system. The complex thermal equipment is an equipment for heat and thermochemical treatment in controlled atmosphere, and a multichamber or continuous heat treatment furnaces, as well as vacuum and ion-plasma equipment, except for specifically complex thermal equipment. The simple thermal equipment is a heat treatment one except for complex and specifically complex thermal equipment.The article gives concrete examples of simple, complex and specifically complex thermal equipment.The criteria to classify the heat treatment technological

  16. IDRC Connect User Guide

    International Development Research Centre (IDRC) Digital Library (Canada)

    Kristina Kamichaitis

    IDRC Extranet home page, which is an umbrella for a number of applications available to IDRC external users. ... IDRC Connect is not formatted for mobile users. ..... Thesis. • Training Material. • Website. • Working Paper. • Workshop Report.

  17. Implicit User Interest Profile

    CERN Document Server

    Chan, K

    2002-01-01

    User interest profile presents items that the users are interested in. Typically those items can be listed or grouped. Listing is good but it does not possess interests at different abstraction levels - the higher-level interests are more general, while the lower-level ones are more specific. Furthermore, more general interests, in some sense, correspond to longer-term interests, while more specific interests correspond to shorter-term interests. This hierarchical user interest profile has obvious advantages: specifying user's specific interests and general interests and representing their relationships. Current user interest profile structures mostly do not use implicit method, nor use an appropriate clustering algorithm especially for conceptually hierarchical structures. This research studies building a hierarchical user interest profile (HUIP) and the hierarchical divisive algorithm (HDC). Several users visit hundreds of web pages and each page is recorded in each users profile. These web pages are used t...

  18. Interventional suite and equipment management: cradle to grave

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Keith J. [Harvard Medical School, Radiology Physics and Engineering, Children' s Hospital Boston, Boston, MA (United States)

    2006-09-15

    The acquisition process for interventional equipment and the care that this equipment receives constitute a comprehensive quality improvement program. This program strives to (a) achieve the production of good image quality that meets clinical needs, (b) reduce radiation doses to the patient and personnel to their lowest possible levels, and (c) provide overall good patient care at reduced cost. Interventional imaging equipment is only as effective and efficient as its supporting facility. The acquisition process of interventional equipment and the development of its environment demand a clinical project leader who can effectively coordinate the efforts of the many professionals who must communicate and work effectively on this type of project. The clinical project leader needs to understand (a) clinical needs of the end users, (b) how to justify the cost of the project, (c) the technical needs of the imaging and all associated equipment, (d) building and construction limitations, (e) how to effectively read construction drawings, and (f) how to negotiate and contract the imaging equipment from the appropriate vendor. After the initial commissioning of the equipment, it must not be forgotten. The capabilities designed into the imaging device can be properly utilized only by well-trained operators and staff who were initially properly trained and receive ongoing training concerning the latest clinical techniques throughout the equipment's lifetime. A comprehensive, ongoing maintenance and repair program is paramount to reducing costly downtime of the imaging device. A planned periodic maintenance program can identify and eliminate problems with the imaging device before these problems negatively impact patient care. (orig.)

  19. Proceedings of the European Symposium on Pressure Equipment - ESOPE 2004

    International Nuclear Information System (INIS)

    2004-01-01

    The symposium on Pressure Equipment Technology, organised every three years by the AFIAP (Association Francaise des Ingenieurs en Appareils a Pression), for the second time is organised at the European level. It is the 'European Symposium on Pressure Equipment, ESOPE 2004'. This symposium is placed under the patronage of the Minister of Industry. The central theme of ESOPE 2001 has been the European Directives for Fixed Equipment (PED) and for Transportable Equipment (TPED). ESOPE 2004 will be a state on the application of these Directives after 3 years of use. The first plenary session will made the comparison of some National codes with EN13445 standard and of the evolution of the Asme code. But the principal theme of the second plenary session and the panel, where European experts will answer to your questions, will be on 'Pressure equipment life management'. It therefore seems important to incorporate this subject into the agenda of this symposium in order to allow widespread dialogue between the industrial members concerned. Our association, AFIAP, has the advantage of regrouping all the industrial partners concerned, from the end user and the administrative body responsible for equipment safety, to the pressure equipment fabricator and his materials suppliers, also including those bodies responsible for design, inspection and certification. To improve availability of equipment and reduce production costs the most efficient way is the development of technology. It is essential to improve competitiveness of European companies. Research is necessary, but the results must be available to everyone, including small and medium-sized industries. ESOPE 2004 has 3 technical sessions in parallel, which will be followed, by many fruitful exchanges of experience: - design/materials - fabrication/welding/inspection - fitness for service. You will find on a CD-Rom all the contributions which have been presented. (authors)

  20. Interventional suite and equipment management: cradle to grave

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    The acquisition process for interventional equipment and the care that this equipment receives constitute a comprehensive quality improvement program. This program strives to (a) achieve the production of good image quality that meets clinical needs, (b) reduce radiation doses to the patient and personnel to their lowest possible levels, and (c) provide overall good patient care at reduced cost. Interventional imaging equipment is only as effective and efficient as its supporting facility. The acquisition process of interventional equipment and the development of its environment demand a clinical project leader who can effectively coordinate the efforts of the many professionals who must communicate and work effectively on this type of project. The clinical project leader needs to understand (a) clinical needs of the end users, (b) how to justify the cost of the project, (c) the technical needs of the imaging and all associated equipment, (d) building and construction limitations, (e) how to effectively read construction drawings, and (f) how to negotiate and contract the imaging equipment from the appropriate vendor. After the initial commissioning of the equipment, it must not be forgotten. The capabilities designed into the imaging device can be properly utilized only by well-trained operators and staff who were initially properly trained and receive ongoing training concerning the latest clinical techniques throughout the equipment's lifetime. A comprehensive, ongoing maintenance and repair program is paramount to reducing costly downtime of the imaging device. A planned periodic maintenance program can identify and eliminate problems with the imaging device before these problems negatively impact patient care. (orig.)

  1. NPAS Users Guide

    International Nuclear Information System (INIS)

    1984-01-01

    This NPAS Users Guide is primarily intended as a source of information about policies, procedures, and facilities appropriate for users in the program of Nuclear Physics at SLAC (NPAS). General policies and practices are described, the preparation of proposals is discussed, and the services for users is outlined. SLAC experimental facilities are described, and contacts are listed

  2. Directory of computer users in nuclear medicine

    International Nuclear Information System (INIS)

    Erickson, J.J.; Gurney, J.; McClain, W.J.

    1979-09-01

    The Directory of Computer Users in Nuclear Medicine consists primarily of detailed descriptions and indexes to these descriptions. A typical Installation Description contains the name, address, type, and size of the institution and the names of persons within the institution who can be contacted for further information. If the department has access to a central computer facility for data analysis or timesharing, the type of equipment available and the method of access to that central computer is included. The dedicated data processing equipment used by the department in its nuclear medicine studies is described, including the peripherals, languages used, modes of data collection, and other pertinent information. Following the hardware descriptions are listed the types of studies for which the data processing equipment is used, including the language(s) used, the method of output, and an estimate of the frequency of the particular study. An Installation Index and an Organ Studies Index are also included

  3. Directory of computer users in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, J.J.; Gurney, J.; McClain, W.J. (eds.)

    1979-09-01

    The Directory of Computer Users in Nuclear Medicine consists primarily of detailed descriptions and indexes to these descriptions. A typical Installation Description contains the name, address, type, and size of the institution and the names of persons within the institution who can be contacted for further information. If the department has access to a central computer facility for data analysis or timesharing, the type of equipment available and the method of access to that central computer is included. The dedicated data processing equipment used by the department in its nuclear medicine studies is described, including the peripherals, languages used, modes of data collection, and other pertinent information. Following the hardware descriptions are listed the types of studies for which the data processing equipment is used, including the language(s) used, the method of output, and an estimate of the frequency of the particular study. An Installation Index and an Organ Studies Index are also included. (PCS)

  4. TDRSS multimode transponder program. Phase 2: Equipment development

    Science.gov (United States)

    Cnossen, R. S.

    1974-01-01

    This report contains a complete description of the TDRS Multimode Transponder and its associated ground support equipment. The transponder will demonstrate candidate modulation techniques to provide the required information for the design of an eventual VHF/UHF transponder suitable for installation in a user satellite, capable of operating as part of a Tracking and Data Relay Satellite (TDRS) systems. Use of geosynchronous TDRS which can serve both low data rate users at VHF and high data rate users at other frequencies has been considered. The effects of radio frequency interference from the earth and of multipath propagation due to reflections from the earth are expected to pose problems for the TDRS system at VHF. Investigations have suggested several modulation techniques that offer promise to overcome these problems.

  5. Performance monitoring of safeguards equipment

    International Nuclear Information System (INIS)

    Sirisena, K.; Peltoranta, M.; Goussarov, V.; Vodrazka, P.

    1999-01-01

    SGTCS is responsible for monitoring and reporting the performance of the SG equipment. Performance monitoring (PM) has been implemented in most important safeguards equipment operating unattended in nuclear facilities. Inspectors acquire equipment performance data in facilities. After inspection, the data package is submitted to SGTCS for processing and analysis. The performance data is used for identification of systems or components, which should be changed in the field and for identification of modules which, should be diagnosed at HQ in order to determine the cause of failure. Moreover, the performance data is used for preventive maintenance and spares distribution planning, and to provide statistics for official reports and management decision making. An important part of the performance monitoring is reporting. Equipment performance reports contain information about equipment inventory, utilization, failure types, failure distribution, and reliability. Trends in performance are given in graphical form in cases, where past data is available. Reliability estimates such as expected times between failures are provided. The automated reporting tools are obtainable through EMIS database application. (author)

  6. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  7. Thermal contact conductance

    CERN Document Server

    Madhusudana, Chakravarti V

    2013-01-01

    The work covers both theoretical and practical aspects of thermal contact conductance. The theoretical discussion focuses on heat transfer through spots, joints, and surfaces, as well as the role of interstitial materials (both planned and inadvertent). The practical discussion includes formulae and data that can be used in designing heat-transfer equipment for a variety of joints, including special geometries and configurations. All of the material has been updated to reflect the latest advances in the field.

  8. Solar thermal in France

    International Nuclear Information System (INIS)

    Letz, T.

    2006-01-01

    This article gives details of Plan Soleil established in 2000 by the French Agency for Environment and Energy Management and its identification of solar hot water systems and combined domestic solar hot water and space heating as promising sectors for development. The setting up of a support scheme for investment by Plan Soleil is discussed along with subsidies and grants, manufacturers and importers, the guarantee of solar results, and the quality of plants, components, and installers. The costs of thermal solar equipment, and results of the French assessment programme are considered. The need for quality standards is stressed

  9. DOSFAC2 user`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Young, M.L.; Chanin, D.

    1997-12-01

    This document describes the DOSFAC2 code, which is used for generating dose-to-source conversion factors for the MACCS2 code. DOSFAC2 is a revised and updated version of the DOSFAC code that was distributed with version 1.5.11 of the MACCS code. included are (1) an overview and background of DOSFAC2, (2) a summary of two new functional capabilities, and (3) a user`s guide. 20 refs., 5 tabs.

  10. Nuclear power generating station equipment qualification method and apparatus

    International Nuclear Information System (INIS)

    Fero, A.H.; Potochnik, L.M.; Riling, R.W.; Semethy, K.F.

    1990-01-01

    This patent describes a method of monitoring an object piece of qualified equipment in a nuclear power plant. It comprises providing a first passive mimic means for mimicking the effect of radiation received by the object piece on the object piece; providing a second mimic means for mimicking the effect of a thermal history of the object piece on the object piece and mounting the first passive mimic means and the second mimic means in close proximity to the object piece

  11. Development of core thermal-hydraulics module for intelligent reactor design system (IRDS)

    International Nuclear Information System (INIS)

    Kugo, Teruhiko; Nakagawa, Masayuki; Fujii, Sadao.

    1994-08-01

    We have developed an innovative reactor core thermal-hydraulics module where a designer can easily and efficiently evaluate his design concept of a new type reactor in the thermal-hydraulics field. The main purpose of this module is to decide a feasible range of basic design parameters of a reactor core in a conceptual design stage of a new type reactor. The module is to be implemented in Intelligent Reactor Design System (IRDS). The module has the following characteristics; 1) to deal with several reactor types, 2) four thermal hydraulics and fuel behavior analysis codes are installed to treat different type of reactors and design detail, 3) to follow flexibly modification of a reactor concept, 4) to provide analysis results in an understandable way so that a designer can easily evaluate feasibility of his concept, and so on. The module runs on an engineering workstation (EWS) and has a user-friendly man-machine interface on a pre- and post-processing. And it is equipped with a function to search a feasible range called as Design Window, for two design parameters by artificial intelligence (AI) technique and knowledge engineering. In this report, structure, guidance for users of an usage of the module and instruction of input data for analysis modules are presented. (author)

  12. 40 CFR 90.329 - Catalyst thermal stress test.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Catalyst thermal stress test. 90.329... Equipment Provisions § 90.329 Catalyst thermal stress test. (a) Oven characteristics. The oven used for thermally stressing the test catalyst must be capable of maintaining a temperature of 500 ±5 °C and 1000 ±10...

  13. Performance Analysis of Diversity-Controlled Multi-User Superposition Transmission for 5G Wireless Networks.

    Science.gov (United States)

    Yeom, Jeong Seon; Chu, Eunmi; Jung, Bang Chul; Jin, Hu

    2018-02-10

    In this paper, we propose a novel low-complexity multi-user superposition transmission (MUST) technique for 5G downlink networks, which allows multiple cell-edge users to be multiplexed with a single cell-center user. We call the proposed technique diversity-controlled MUST technique since the cell-center user enjoys the frequency diversity effect via signal repetition over multiple orthogonal frequency division multiplexing (OFDM) sub-carriers. We assume that a base station is equipped with a single antenna but users are equipped with multiple antennas. In addition, we assume that the quadrature phase shift keying (QPSK) modulation is used for users. We mathematically analyze the bit error rate (BER) of both cell-edge users and cell-center users, which is the first theoretical result in the literature to the best of our knowledge. The mathematical analysis is validated through extensive link-level simulations.

  14. FEL diagnostics and user control

    International Nuclear Information System (INIS)

    Knippels, G.M.H.; Meer, A.F.G. van der

    1998-01-01

    The most recent upgrades and improvements to the free-electron laser (FEL) facility FELIX are presented. Special attention is paid to the improved beam-handling and diagnostic station. In this evacuated beam station a device is implemented that is capable of selecting single micropulses with measured efficiencies of more than 50% over the whole wavelength range of FELIX (5-110 μm). Furthermore, the broadband autocorrelator for micropulse length measurements and the planned continuous polarization rotator based on reflective optics are discussed. Recent additions to the ancillary equipment available to FEL users are presented briefly. The most important ones are the mirror-dispersion-controlled 10-fs Ti:sapphire laser and the 40-T magnet. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  15. Another donation of computer equipment

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On Thursday 27 February, CERN was pleased to donate computer equipment to a physics institute in the Philippines.   H.E. Leslie J. Baja and Rolf Heuer. Following donations of computer equipment to institutes in Morocco, Ghana, Bulgaria, Serbia and Egypt, CERN is to send 50 servers and 4 network switches to the National Institute of Physics at the University of the Philippines Diliman. CERN’s Director-General Rolf Heuer and the Ambassador of the Philippines to Switzerland and Lichtenstein, H.E. Leslie J. Baja, spoke of their enthusiasm for the project during an official ceremony. The equipment will be used for various high energy physics research programmes in the Philippines and for the University’s development of digital resources for science.

  16. Controlling the quality of replacement parts in nuclear station, class 1E equipment

    International Nuclear Information System (INIS)

    Pierson, R.K.; Clemons, R.W.

    1984-01-01

    Nuclear station owners have traditionally purchased replacement parts for Class 1E equipment from the original supplier of the equipment. By this method, part and equipment quality could be maintained. In recent years, however, this traditional source of parts has continuously declined as an increasing number of original equipment suppliers stop producing Class 1E equipment or no longer stock parts for older equipment. When replacement parts for Class 1E equipment are not obtainable from the original suppliers, equipment owners have created a variety of methods for assuring the quality of parts obtained from other sources. A standard that provides direction and guidance for maintaining the quality of Class 1E equipment when repaired with parts from alternate sources is, therefore, needed to assure the methods in use are satisfactory and to alert the equipment owners to additional acceptable methods. The standard has now been proposed. IEEE Standard P934 (June, 1983 Draft): ''Requirements for Replacement Parts for Class 1E Equipment in Nuclear Power Generating Stations'' (Ref-3) consist of an introductory section followed by sections on part selection, procurement, replacement (including inspections and tests), non-conforming conditions and records. The proposed standard also includes a non-mandatory appendix on acceptable procurement methods and a summary intended to assist the user in selecting a proper procurement method

  17. User interface design considerations

    DEFF Research Database (Denmark)

    Andersen, Simon Engedal; Jakobsen, Arne; Rasmussen, Bjarne D.

    1999-01-01

    and output variables. This feature requires special attention when designing the user interface and a special approach for controlling the user selection of input and output variables are developed. To obtain a consistent system description the different input variables are grouped corresponding......When designing a user interface for a simulation model there are several important issues to consider: Who is the target user group, and which a priori information can be expected. What questions do the users want answers to and what questions are answered using a specific model?When developing...... the user interface of EESCoolTools these issues led to a series of simulation tools each with a specific purpose and a carefully selected set of input and output variables. To allow a more wide range of questions to be answered by the same model, the user can change between different sets of input...

  18. User Evaluation of Neonatology Ward Design.

    Science.gov (United States)

    Trujillo, Juan Luis Higuera; Aviñó, Antoni Montañana I; Millán, Carmen Llinares

    2017-01-01

    The object of this article is to identify the set of affective and emotional factors behind users' assessments of a space in a neonatology unit and to propose design guidelines based on these. The importance of the neonatology service and the variety of users place great demands on the space at all levels. Despite the repercussions, the emotional aspects of the environment have received less attention. To avoid incurring limitations in the user mental scheme, this study uses two complementary methodologies: focus group and semantic differential. The (qualitative) focus group methodology provides exploratory information and concepts. The (quantitative) semantic differential methodology then uses these concepts to extract the conceptual structures that users employ in their assessment of the space. Of the total 175 subjects, 31 took part in focus groups and 144 in semantic differential. Five independent concepts were identified: privacy, functionality and professional nature, spaciousness, lighting, and cleanliness. In relation to the importance of the overall positive assessment of the space, the perception of privacy and sensations of dominance and pleasure are fundamental. Six relevant design aspects were also identified: provide spacious surroundings, facilitate sufficient separation between the different posts or cots, use different colors from those usually found in health-care centers, as some aversion was found to white and especially green, design areas with childhood themes, use warm artificial light, and choose user-friendly equipment. Results provide design recommendations of interest and show the possibilities offered by combining both systems to analyze user response.

  19. Waste Electrical and Electronic Equipment

    DEFF Research Database (Denmark)

    Bigum, Marianne Kristine Kjærgaard; Christensen, Thomas Højlund

    2011-01-01

    Waste electrical and electronic equipment (WEEE) is one of the fastest growing special waste types with an estimated growth of 3–5% per year (Cui and Forssberg, 2003). WEEE is a very heterogeneous waste type that contains many compounds that are considered to be harmful to both humans and the env......Waste electrical and electronic equipment (WEEE) is one of the fastest growing special waste types with an estimated growth of 3–5% per year (Cui and Forssberg, 2003). WEEE is a very heterogeneous waste type that contains many compounds that are considered to be harmful to both humans...

  20. The development of superconducting equipment

    CERN Document Server

    Ueda, T; Hiue, H

    2003-01-01

    Fuji Electric has been developing various types of superconducting equipment for over a quarter of a century. This paper describes the development results achieved for superconducting equipment and especially focuses on large-capacity current leads and superconducting transmission systems, the development of which is being promoted for application to the field of nuclear fusion. High temperature superconductor (HTS) is becoming the mainstream in the field of superconductivity, and the HTS floating coil and conduction-cooled HTS transformed are also introduced as recent developments for devices that utilize this technology. (author)

  1. Mechanical (turbines and auxiliary equipment)

    CERN Document Server

    Sherry, A; Cruddace, AE

    2013-01-01

    Modern Power Station Practice, Volume 3: Mechanical (Turbines and Auxiliary Equipment) focuses on the development of turbines and auxiliary equipment used in power stations in Great Britain. Topics covered include thermodynamics and steam turbine theory; turbine auxiliary systems such as lubrication systems, feed water heating systems, and the condenser and cooling water plants. Miscellaneous station services, and pipework in power plants are also described. This book is comprised of five chapters and begins with an overview of thermodynamics and steam turbine theory, paying particular attenti

  2. Thermal insulation

    International Nuclear Information System (INIS)

    Aspden, G.J.; Howard, R.S.

    1988-01-01

    The patent concerns high temperature thermal insulation of large vessels, such as the primary vessel of a liquid metal cooled nuclear reactor. The thermal insulation consists of multilayered thermal insulation modules, and each module comprises a number of metal sheet layers sandwiched between a back and front plate. The layers are linked together by straps and clips to control the thickness of the module. (U.K.)

  3. Control of Nuclear Materials and Special Equipment (Nuclear Safety Regulations)

    International Nuclear Information System (INIS)

    Cizmek, A.; Prah, M.; Medakovic, S.; Ilijas, B.

    2008-01-01

    Based on Nuclear Safety Act (OG 173/03) the State Office for Nuclear Safety (SONS) in 2008 adopted beside Ordinance on performing nuclear activities (OG 74/06) and Ordinance on special conditions for individual activities to be performed by expert organizations which perform activities in the area of nuclear safety (OG 74/06) the new Ordinance on the control of nuclear material and special equipment (OG 15/08). Ordinance on the control of nuclear material and special equipment lays down the list of nuclear materials and special equipment as well as of nuclear activities covered by the system of control of production of special equipment and non-nuclear material, the procedure for notifying the intention to and filing the application for a license to carry out nuclear activities, and the format and contents of the forms for doing so. This Ordinance also lays down the manner in which nuclear material records have to be kept, the procedure for notifying the State administration organization (regulatory body) responsible for nuclear safety by the nuclear material user, and the keeping of registers of nuclear activities, nuclear material and special equipment by the State administration organization (regulatory body) responsible for nuclear safety, as well as the form and content of official nuclear safety inspector identification card and badge.(author)

  4. Vault Safety and Inventory System users manual, PRIME 2350. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Downey, N.J.

    1994-12-14

    This revision is issued to request review of the attached document: VSIS User Manual, PRIME 2350, which provides user information for the operation of the VSIS (Vault Safety and Inventory System). It describes operational aspects of Prime 2350 minicomputer and vault data acquisition equipment. It also describes the User`s Main Menu and menu functions, including REPORTS. Also, system procedures for the Prime 2350 minicomputer are covered.

  5. Computerized system for energy diagnosis in domestic users; Sistema computarizado para diagnostico energetico en usuarios domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Ramos N, Gaudencio; Heard, Cristopher; Fiscal E, Raul; Maqueda Z, Martin [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    The scope of a computerized system is presented to make an energy diagnosis to homes and a simulation of scenarios of cost/benefit, due to the implementation of energy saving measures and the efficient use of electrical energy. The FIPATERM (trust for the heat insulation of the house in Mexicali), provides economic and technical support so that the domestic users diminish their expense for the electrical energy, implementing programs of Demand Side Management (DSM). The current effective programs are: thermal insulation, substitution of the existent air conditioning units for efficient ones, reduction of infiltration, leveled plan of payments, interruption of the air conditioning equipment. In order to participate in one or several of the programs of energy efficiency, an energy diagnosis is made to the user. It is from a survey of the equipment and characteristics of the house, as well as a description on the part of the user of his habits of use of the equipment, that scenarios are simulated, which allow the user to identify the most profitable measures. [Spanish] Se presenta el alcance de un sistema computarizado para realizar diagnostico energetico a casas habitacion y simulacion de escenarios de beneficio/costo, debido a la implantacion de medidas de ahorro y uso eficiente de energia electrica. El FIPATERM (fideicomiso para el aislamiento termico de la vivienda en Mexicali), proporciona apoyo economico y tecnico para que los usuarios domesticos minimicen su gasto de energia electrica, implementando programas de Administracion por el Lado de la Demanda (ALD). Los programas actualmente vigentes son: aislamiento termico, sustitucion del aire acondicionado actual por uno eficiente, reduccion de infiltracion, plan nivelado de pagos, interrupcion del equipo de aire acondicionado. Para participar en uno o varios de los programas de eficiencia energetica, al usuario se le realiza un diagnostico energetico. Es a partir de una encuesta del equipamiento y caracteristicas

  6. User rights management of the CSNS control system client

    International Nuclear Information System (INIS)

    Zhang Zhuoyu; Liu Minqian; Chu Yuanping; Zhuang Jian; Hu Lei; Jin Dapeng

    2012-01-01

    The China Spallation Neutron Source (CSNS) will become the first pulsed spallation neutron source owned by China, CSS (Control System Studio), used as the the target station and spectrometer control system client, is mainly responsible for equipment controlling and parameter monitoring. In order to ensure the safety of the control system, the advanced GUI and important operating parameters must be restricted to ordinary users, only senior experts have the rights to view and modify them, so we must divide CSS users into different groups and give different rights to different groups. Based on user roles, CSS can implicit workbench contents and widgets, to ensure that users can seamlessly log into different clients. This article mainly talk about the JAAS authentication and authorization services in CSS, and deploy user information and master-slave synchronization information on the LDAP server, and use the Eclipse activity extension points to accomplish GUI explicit-implicit control according to the logged in user. (authors)

  7. User-centered design

    International Nuclear Information System (INIS)

    Baik, Joo Hyun; Kim, Hyeong Heon

    2008-01-01

    The simplification philosophy, as an example, that both of EPRI-URD and EUR emphasize is treated mostly for the cost reduction of the nuclear power plants, but not for the simplification of the structure of user's tasks, which is one of the principles of user-centered design. A user-centered design is a philosophy based on the needs and interests of the user, with an emphasis on making products usable and understandable. However, the nuclear power plants offered these days by which the predominant reactor vendors are hardly user-centered but still designer-centered or technology-centered in viewpoint of fulfilling user requirements. The main goal of user-centered design is that user requirements are elicited correctly, reflected properly into the system requirements, and verified thoroughly by the tests. Starting from the user requirements throughout to the final test, each requirement should be traceable. That's why requirement traceability is a key to the user-centered design, and main theme of a requirement management program, which is suggested to be added into EPRI-URD and EUR in the section of Design Process. (author)

  8. Damage limits of accelerator equipment

    CERN Document Server

    Rosell, Gemma

    2014-01-01

    Beam losses occur in particle accelerators for various reasons. The effect of lost particles on accelerator equipment becomes more severe with the increasing energies and intensities. The present study is focused on the damage potential of the proton beam as a function of particle energy and beam size. Injection and extraction energies of different accelerators at CERN were considered.

  9. Pocket dictionary of laboratory equipment

    International Nuclear Information System (INIS)

    Junge, H.D.

    1987-01-01

    This pocket dictionary contains the 2500 most common terms for scientific and technical equipment in chemical laboratories. It is a useful tool for those who are used to communicating in German and English, but have to learn the special terminology in this field. (orig.) [de

  10. Using Gaming Equipment to Teach

    Science.gov (United States)

    Curriculum Review, 2009

    2009-01-01

    Gaming equipment (such as Nintendo's Wii[TM]) is making its way to schools and classrooms. However, most of the discussion regarding how to use this technology and integrate it into lesson plans is happening in blogs on the Internet. An advocate of interactive media in the classroom, Dr. Dawn Hawkins, a faculty member for the Art Institute of…

  11. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  12. Hydraulic turbines and auxiliary equipment

    Energy Technology Data Exchange (ETDEWEB)

    Luo Gaorong [Organization of the United Nations, Beijing (China). International Centre of Small Hydroelectric Power Plants

    1995-07-01

    This document presents a general overview on hydraulic turbines and auxiliary equipment, emphasizing the turbine classification, in accordance with the different types of turbines, standard turbine series in China, turbine selection based on the basic data required for the preliminary design, general hill model curves, chart of turbine series and the arrangement of application for hydraulic turbines, hydraulic turbine testing, and speed regulating device.

  13. 47 CFR 68.348 - Changes in equipment and circuitry subject to a Supplier's Declaration of Conformity.

    Science.gov (United States)

    2010-10-01

    ... Supplier's Declaration of Conformity. 68.348 Section 68.348 Telecommunication FEDERAL COMMUNICATIONS... a Supplier's Declaration of Conformity. (a) No change shall be made in terminal equipment or... Declaration of Conformity Statement furnished to users. (b) Any other changes in terminal equipment or...

  14. Thermal insulation

    International Nuclear Information System (INIS)

    Pinsky, G.P.

    1977-01-01

    Thermal insulation for vessels and piping within the reactor containment area of nuclear power plants is disclosed. The thermal insulation of this invention can be readily removed and replaced from the vessels and piping for inservice inspection, can withstand repeated wettings and dryings, and can resist high temperatures for long periods of time. 4 claims, 3 figures

  15. NOW ON THE WEB SALES AND PURCHASE OF OBSOLETE OR SURPLUS EQUIPMENT

    CERN Multimedia

    2000-01-01

    The Recuperation and Sales Service wishes to recall that obsolete or surplus equipment which is no longer needed at CERN may be sold to outside institutes, members of the personnel, companies, etc. For this purpose an 'on-line sales and purchase tool' has been developed and installed on the web: consult the 'Recuperation and Sales Service' site on the CERN homepage. Users wishing to eliminate or sell obsolete or surplus equipment are invited to use the tool to issue an 'on-line sales request' and users who are looking for cheap 2nd hand equipment may consult the 'on-line sales catalogue' and make 'on-line purchase bids'. The direct sale of low value equipment, which takes place Thursdays 13h30 ­ 15h30 in the Recuperation Centre, building 133, will continue as before. For more information contact the Recuperation & Sales Service, tel. 75782 or 78665.

  16. International user studies

    DEFF Research Database (Denmark)

    Nielsen, Lene; Madsen, Sabine; Jensen, Iben

    In this report, we present the results of a research project about international user studies. The project has been carried out by researchers from the Center for Persona Research and –Application, The IT University in Copenhagen and the Department of Learning and Philosophy, Aalborg University...... in Sydhavnen, and it is funded by InfinIT. Based on a qualitative interview study with 15 user researchers from 11 different companies, we have investigated how companies collect and present data about users on international markets. Key findings are: Companies do not collect data about end users in all...... the countries/regions they operate in. Instead, they focus on a few strategic markets. International user studies tend to be large-scale studies that involve the effort of many both internal and external/local human resources. The studies typically cover 2-4 countries/regions and many end users in each country...

  17. Alternative Fuels Data Center: Biodiesel Equipment Options

    Science.gov (United States)

    Equipment Options to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Equipment Options on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Equipment Options on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Equipment Options on Google Bookmark Alternative Fuels

  18. 40 CFR 792.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Equipment design. 792.61 Section 792.61...) GOOD LABORATORY PRACTICE STANDARDS Equipment § 792.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  19. 40 CFR 160.61 - Equipment design.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Equipment design. 160.61 Section 160... LABORATORY PRACTICE STANDARDS Equipment § 160.61 Equipment design. Equipment used in the generation... appropriate design and adequate capacity to function according to the protocol and shall be suitably located...

  20. 21 CFR 58.61 - Equipment design.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Equipment design. 58.61 Section 58.61 Food and... PRACTICE FOR NONCLINICAL LABORATORY STUDIES Equipment § 58.61 Equipment design. Equipment used in the... of appropriate design and adequate capacity to function according to the protocol and shall be...

  1. 34 CFR 74.34 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... as program income. (e) When acquiring replacement equipment, the recipient may use the equipment to... replacement equipment subject to the approval of the Secretary. (f) The recipient's property management... 34 Education 1 2010-07-01 2010-07-01 false Equipment. 74.34 Section 74.34 Education Office of the...

  2. 20 CFR 437.32 - Equipment.

    Science.gov (United States)

    2010-04-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use.... Procedures for managing equipment (including replacement equipment), whether acquired in whole or in part... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Equipment. 437.32 Section 437.32 Employees...

  3. 45 CFR 2541.320 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... replacement equipment, the grantee or subgrantee may use the equipment to be replaced as a trade-in or sell... replacement equipment), whether acquired in whole or in part with grant funds, until disposition takes place... ensure the highest possible return. (e) Disposition. When original or replacement equipment acquired...

  4. 45 CFR 1174.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  5. 45 CFR 1157.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... contemplated by Federal statute. (4) When acquiring replacement equipment, the grantee or subgrantee may use... requirements. Procedures for managing equipment (including replacement equipment), whether acquired in whole or... original or replacement equipment acquired under a grant or subgrant is no longer needed for the original...

  6. The Cost of Maintaining Educational Communications Equipment.

    Science.gov (United States)

    Humphrey, David A.

    Tentative formulas for calculating the cost of maintaining educational communications equipment are proposed. The formulas are based on a survey of campuses of the State University of New York. The survey analyzed the types of equipment to be maintained, types of maintenance, who uses the equipment, who services the equipment, and the cost…

  7. (According to TAS 16, Measurement After Recognition on Property, Plant andEquipment and Accounting İmplementation)

    OpenAIRE

    Örten, Remzi; Bayırlı, Rıdvan

    2007-01-01

    The objective of TAS 16 is to prescribe the accounting treatment for property, plant and equipment so that users of the financial statements can determine information about an entity’s investment in its property, plant and equipment and the changes in such investment. Property, plant and equipment have major importance within the total assets of companies and thus they are very significant in the determination of financial analysis. According to this standard, there are two methods cencerning...

  8. ER-E4 regulation. Transitional arrangement to implement the rules for evaluating and state control of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Establish a regulatory document where the validity and status of the documents contained in the Regulatory Legal Base Technical Program of medical equipment is exposed, given the scope thereof to comply with the provisions of the Regulation. This regulation is aimed at all subjects (manufacturers or producers, suppliers or distributors, importers, users, medical equipment, as well as health institutions SNS) involved in activities related to the evaluation and control of the State Medical equipment and make use of complementary technical legal documents.

  9. MADS Users' Guide

    Science.gov (United States)

    Moerder, Daniel D.

    2014-01-01

    MADS (Minimization Assistant for Dynamical Systems) is a trajectory optimization code in which a user-specified performance measure is directly minimized, subject to constraints placed on a low-order discretization of user-supplied plant ordinary differential equations. This document describes the mathematical formulation of the set of trajectory optimization problems for which MADS is suitable, and describes the user interface. Usage examples are provided.

  10. The user's view of commercially available medical technology

    Science.gov (United States)

    Harrison, D. C.

    1975-01-01

    The potential user of new medical equipment for imaging the cardiovascular system is often faced with the problem of deciding whether or not to accept a new piece of equipment or a new technological concept into the practice of cardiology. Considerations for acquiring new medical technology are discussed in some detail. Acquisition of new technology should depend on whether the equipment provides more and relevant clinical data, is for research or for limited use, is properly engineered for patient use, presents information in easily storable and retrievable form, is tested and validated clinically, is fabricated by a reliable manufacturer, is cost effective, and may be readily replaced by a new technology.

  11. Measuring user engagement

    CERN Document Server

    Lalmas, Mounia; Yom-Tov, Elad

    2014-01-01

    User engagement refers to the quality of the user experience that emphasizes the positive aspects of interacting with an online application and, in particular, the desire to use that application longer and repeatedly. User engagement is a key concept in the design of online applications (whether for desktop, tablet or mobile), motivated by the observation that successful applications are not just used, but are engaged with. Users invest time, attention, and emotion in their use of technology, and seek to satisfy pragmatic and hedonic needs. Measurement is critical for evaluating whether online

  12. Web-users identification

    OpenAIRE

    Kazakov, Ilja

    2017-01-01

    The main goal of this thesis is to determine what parameters (of a browser fingerprint) are necessary in order to identify a user in a specific interval (number of users). The secondary goal is to try to assign fingerprints to users. The final goal is to find out the weight of each parameter (usefulness). The thesis consists of two main parts: data collection (up to 10000 users) and analysis of the data. As a result, with help of an implemented JavaScript plugin, a database, which consists of...

  13. User participation in implementation

    DEFF Research Database (Denmark)

    Fleron, Benedicte; Rasmussen, Rasmus; Simonsen, Jesper

    2012-01-01

    Systems development has been claimed to benefit from user participation, yet user participation in implementation activities may be more common and is a growing focus of participatory-design work. We investigate the effect of the extensive user participation in the implementation of a clinical...... experienced more uncertainty and frustration than management and non-participating staff, especially concerning how to run an implementation process and how to understand and utilize the configuration possibilities of the system. This suggests that user participation in implementation introduces a need...

  14. MLF user program

    International Nuclear Information System (INIS)

    Kamiyama, Takashi; Ikeda, Yujiro

    2008-01-01

    The user program of J-PARC/MLF is overviewed. Since MLF will be one of the major neutron facilities in the world, an international standard system for the user program is expected. It is also expected to establish a system to promote users from industries. The MLF user program is based on the IUPAP recommendation on the selection of proposals. Both open and closed accesses, biannual, regular, rapid accesses, etc. will be provided. All the features in the system are being introduced to maximize both scientific and engineering outputs from MLF. (author)

  15. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    Science.gov (United States)

    Rossel, R. E.; Fedosseev, V. N.; Marsh, B. A.; Richter, D.; Rothe, S.; Wendt, K. D. A.

    2013-12-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The system contributes to four key aspects of RILIS operation: equipment monitoring, machine protection, automated self-reliance, and collaborative data acquisition. The overall concept, technologies used, implementation status and recent applications during the 2012 on-line operation period will be presented along with a summary of future developments.

  16. Queuing theory models used for port equipment sizing

    Science.gov (United States)

    Dragu, V.; Dinu, O.; Ruscă, A.; Burciu, Ş.; Roman, E. A.

    2017-08-01

    The significant growth of volumes and distances on road transportation led to the necessity of finding solutions to increase water transportation market share together with the handling and transfer technologies within its terminals. It is widely known that the biggest times are consumed within the transport terminals (loading/unloading/transfer) and so the necessity of constantly developing handling techniques and technologies in concordance with the goods flows size so that the total waiting time of ships within ports is reduced. Port development should be achieved by harmonizing the contradictory interests of port administration and users. Port administrators aim profit increase opposite to users that want savings by increasing consumers’ surplus. The difficulty consists in the fact that the transport demand - supply equilibrium must be realised at costs and goods quantities transiting the port in order to satisfy the interests of both parties involved. This paper presents a port equipment sizing model by using queueing theory so that the sum of costs for ships waiting operations and equipment usage would be minimum. Ship operation within the port is assimilated to a mass service waiting system in which parameters are later used to determine the main costs for ships and port equipment.

  17. A guide to radiation protection in the use of X-ray optics equipment

    International Nuclear Information System (INIS)

    Bines, W.P.

    1986-01-01

    A booklet has been produced by a Working Group convened by the Health and Safety Executive to provide practical guidance for all who might be involved in work with X-ray optics equipment, such as designers, manufacturers, users, maintenance workers, inspectors, radiation protection advisers and supervisors. The particular radiation protection aspects described include those in connection with enclosure design and inspection, inter locks, tube shields, shutters and cover plates, administrative controls, monitoring and repair and maintenance of equipment. (UK)

  18. EM-18-2008 regulation. Essential requirements for the registration of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    This rule lays down additional rules for the evaluation and the State Control of Medical Equipment provisions. Medical equipment must be designed and constructed so that they are used under the conditions and for the intended purpose and shall, where applicable, by virtue of the technical knowledge, experience, education or training of users, do not compromise the clinical condition or safety of patients, or the safety and health of users or, where applicable, other persons, assuming that any risks that may be associated with their use constitute acceptable risks versus the benefits for the patient and is compatible with a high level of protection of health and safety.

  19. Demonstrator 1: User Interface and User Functions

    DEFF Research Database (Denmark)

    Gram, Christian

    1999-01-01

    Describes the user interface and its functionality in a prototype system used for a virtual seminar session. The functionality is restricted to what is needed for a distributed seminar discussion among not too many people. The system is designed to work with the participants distributed at several...

  20. [Equipment and technology in robotics].

    Science.gov (United States)

    Murphy, Declan; Challacombe, Ben; Nedas, Tim; Elhage, Oussama; Althoefer, Kaspar; Seneviratne, Lakmal; Dasgupta, Prokar

    2007-05-01

    We review the evolution and current status of robotic equipment and technology in urology. We also describe future developments in the key areas of virtual reality simulation, mechatronics and nanorobotics. The history of robotic technology is reviewed and put into the context of current systems. Experts in the associated fields of nanorobotics, mechatronics and virtual reality simulation simulation review the important future developments in these areas.

  1. Remote handling equipment for SNS

    International Nuclear Information System (INIS)

    Poulten, B.H.

    1983-01-01

    This report gives information on the areas of the SNS, facility which become highly radioactive preventing hands-on maintenance. Levels of activity are sufficiently high in the Target Station Area of the SNS, especially under fault conditions, to warrant reactor technology to be used in the design of the water, drainage and ventilation systems. These problems, together with the type of remote handling equipment required in the SNS, are discussed

  2. Margins related to equipment design

    International Nuclear Information System (INIS)

    Devos, J.

    1994-01-01

    Safety margins related to design of reactor equipment are defined according to safety regulations. Advanced best estimate methods are proposed including some examples which were computed and compared to experimental results. Best estimate methods require greater computation effort and more material data but give better variable accuracy and need careful experimental validation. Simplified methods compared to the previous are less sensitive to material data, sometimes are more accurate but very long to elaborate

  3. Temperature radiation measuring equipment. Temperaturstrahlungsmessgeraet

    Energy Technology Data Exchange (ETDEWEB)

    Lotzer, W

    1981-01-22

    The invention is concerned with a temperature radiation measuring equipment for non-contact temperature measurement by the light intensity variation method, with a photoelectric resistance as the measuring element. By having a circuit with a transistor, the 'dark resistance' occurring in the course of time is compensated for and thus gives a genuine reading (ie. the voltage drop across the photoelectric resistance remains constant).

  4. COSIS User's Manual

    International Nuclear Information System (INIS)

    Cho, J. Y.; Lee, K. B.; Koo, B. S.; Lee, W. K.; Lee, C. C.; Zee, S. Q.

    2006-02-01

    COSIS (COre State Indication System) which implemented in the SMART research reactor plays a role to supply the core state parameters or graphs for the operator to recognize the core state effectively. The followings are the main functions of COSIS. Validity Check for the Process Signals and Determination of the COSIS Inputs (SIGVAL), Coolant Flow Rate Calculation (FLOW), Core Thermal Power Calculation (COREPOW), In-core 3-Dimensional Power Distribution Calculation and Peaking Parameters Generation (POWER3D), Azimuthal Tilt Calculation (AZITILT). This report describes the structures of the I/O files that are essential for the users to run COSIS. COSIS handles the following 4 input files. DATABASE: The base input file, COSIS.INP: The signal input file, CCS.DAT: File required for the in-core detector signal processing and the 3-D power distribution calculation, TPFH2O: Steam table for the water properties The DATABASE file contains the base information for a nuclear power plant and is read at the first COSIS calculation. The COSIS.INP file contains the process input and detector signals, and is read by COSIS at every second. CCS.DAT file, that is produced by the COSISMAS code, contains the information for the in-core detector signal processing and the 3-D power distribution calculation. TPFH2O file is a steam table and is written in binary format. COSIS produces the following 4 output files. DATABASE.OUT: The output file for the DATABASE input file, COSIS.OUT: The normal output file produced after the COSIS calculation, COSIS.SUM: File for the operator to recognize the core state effectively, MAS S IG: File to run the COSISMAS code The DATABASE.OUT file is produced right after finishing DATABASE processing. The COSIS.OUT file is produced after finishing the input signal processing and the main COSIS calculation. The COSIS.SUM file is the summary file of the COSIS results for the operator to recognize the core state effectively. The MAS S IG file is the COSISMAS input

  5. CERN computing equipment for Senegal

    CERN Multimedia

    Anaïs Schaeffer

    2014-01-01

    On 26 May, CERN once again had the honour of donating computing equipment to a foreign institute.   This time, around 100 servers and five network hubs were sent to Senegal, making it the seventh country, after Morocco, Ghana, Bulgaria, Serbia, Egypt and the Philippines, to receive a donation of computing equipment from the Organization. The official ceremony was held at CERN on 26 May in the presence of the Director-General, Rolf Heuer, and Senegal's ambassador to Geneva, Fodé Seck, who both expressed their enthusiasm for the project. The equipment is intended for Cheikh Anta Diop University (UCAD) in Dakar and will be of particular use to students attending the African School of Fundamental Physics and its Applications (ASP 2014) taking place from 3 to 23 August, for which CERN is a partner. The ASP allows a large number of African students to hone their skills in high-energy physics and to forge professional links with fellow physicists in Africa and Europe. ...

  6. Spacecraft Thermal Management

    Science.gov (United States)

    Hurlbert, Kathryn Miller

    2009-01-01

    In the 21st century, the National Aeronautics and Space Administration (NASA), the Russian Federal Space Agency, the National Space Agency of Ukraine, the China National Space Administration, and many other organizations representing spacefaring nations shall continue or newly implement robust space programs. Additionally, business corporations are pursuing commercialization of space for enabling space tourism and capital business ventures. Future space missions are likely to include orbiting satellites, orbiting platforms, space stations, interplanetary vehicles, planetary surface missions, and planetary research probes. Many of these missions will include humans to conduct research for scientific and terrestrial benefits and for space tourism, and this century will therefore establish a permanent human presence beyond Earth s confines. Other missions will not include humans, but will be autonomous (e.g., satellites, robotic exploration), and will also serve to support the goals of exploring space and providing benefits to Earth s populace. This section focuses on thermal management systems for human space exploration, although the guiding principles can be applied to unmanned space vehicles as well. All spacecraft require a thermal management system to maintain a tolerable thermal environment for the spacecraft crew and/or equipment. The requirements for human rating and the specified controlled temperature range (approximately 275 K - 310 K) for crewed spacecraft are unique, and key design criteria stem from overall vehicle and operational/programatic considerations. These criteria include high reliability, low mass, minimal power requirements, low development and operational costs, and high confidence for mission success and safety. This section describes the four major subsystems for crewed spacecraft thermal management systems, and design considerations for each. Additionally, some examples of specialized or advanced thermal system technologies are presented

  7. A novel approach to collaborative product development in the medical-equipment industry

    OpenAIRE

    Tseng, Kevin C; Chien-Lung, Hsu

    2013-01-01

    In this study, we summarise the requirements for collaborative product development based on our investigation of the differences in the resources and tools that are needed for the various stages of collaborative product development and the needs of system users during these various stages. We proposed a user-oriented approach of collaborative product development for medical equipment and designed a collaborative product development system with the required functionalities to satisfy different...

  8. EMI New User Communities

    CERN Document Server

    Riedel, M

    2013-01-01

    This document provides pieces of information about new user communities that directly or indirectly take advantage of EMI Products. Each user community is described via one specific EMI product use case to understand and communicate the current usage of EMI Products in practice.

  9. Additional user needs

    International Nuclear Information System (INIS)

    Rorschach, H.E.; Hayter, J.B.

    1986-01-01

    This paper summarizes the conclusions of a discussion group on users' needs held at the Workshop on an Advanced Steady-State Neutron Facility. The discussion was devoted to reactor characteristics, special facilities and siting considerations suggested by user needs. (orig.)

  10. Users in Persistant Action

    DEFF Research Database (Denmark)

    Christiansen, John K.; Gasparin, Marta; Varnes, Claus J.

    2012-01-01

    of the hybrid collective to include the press and distribution channels to want it back. All actors in collective actions can become lead users when supported by establishing alliances. This perspective is different from Von Hippel (1986) who is claiming that the trend needs to be defined before the lead users...

  11. User Interface History

    DEFF Research Database (Denmark)

    Jørgensen, Anker Helms; Myers, Brad A

    2008-01-01

    User Interfaces have been around as long as computers have existed, even well before the field of Human-Computer Interaction was established. Over the years, some papers on the history of Human-Computer Interaction and User Interfaces have appeared, primarily focusing on the graphical interface e...

  12. Users are problem solvers!

    NARCIS (Netherlands)

    Brouwer-Janse, M.D.

    1991-01-01

    Most formal problem-solving studies use verbal protocol and observational data of problem solvers working on a task. In user-centred product-design projects, observational studies of users are frequently used too. In the latter case, however, systematic control of conditions, indepth analysis and

  13. Seizing market shaping opportunities for vaccine cold chain equipment.

    Science.gov (United States)

    Azimi, Tara; Franzel, Lauren; Probst, Nina

    2017-04-19

    Gavi, the Vaccine Alliance, supports immunisation programmes in eligible countries to reach children with lifesaving vaccines. Dramatic improvement in the scale and performance of current cold chain systems is required to extend the reach of immunisation services - especially for children living in remote locations - to advance progress towards full vaccine coverage. Achieving these improvements will require a healthier market for cold chain equipment where the products meet user needs, are sustainably priced, and are available in sufficient quantities to meet demand. Yet evidence suggests that the cold chain market has suffered from several failures including limited demand visibility, fragmented procurement, and insufficient information exchange between manufacturers and buyers on needs and equipment performance. One of Gavi's strategic goals is to shape markets for vaccines and other immunisation products, including cold chain equipment and in 2015, Gavi created a new mechanism - the Cold Chain Equipment (CCE) Optimisation Platform - to strengthen country cold chain systems by offering financial support and incentives for higher performing CCE. The main objective of the CCE Platform is to get more equipment that is efficient, sustainable, and better performing deployed to every health facility where it is required at an affordable price. To achieve these objectives, Gavi is putting in place tested market shaping approaches and tools adapted for the CCE market: the development of market strategies or 'roadmaps'; improvement of product performance through the development of target product profiles (TPPs); strategic engagement with CCE manufacturers and countries to enhance information sharing; and tailoring procurement tactics to the CCE market. These approaches and tools will allow for increased demand and supply of higher-performing, cost-effective and quality products. By strengthening immunisation systems with improved cold chain equipment, Gavi countries can

  14. The oil and gas equipment and services market in Nigeria

    International Nuclear Information System (INIS)

    2003-01-01

    The oil and gas market in Nigeria is being expanded by the Nigerian government over the 2003-2010 period through increased exploration and production (E and P) in new areas. Other measures being implemented are the improvements of structural flaws that hamper industry growth, the modernization of the weak downstream sector, and attempts to attract foreign investment and technologies required for petroleum development. In 2001, it was estimated that the market for oil and gas equipment in Nigeria was approximately 1.03 billion dollars, and is expected to reach 1.15 billion dollars in 2002. In deep-sea areas, major offshore E and P projects are being planned by large oil multinationals. The implementation of several gas-related E and P operations and major liquefied natural gas (LNG) and gas-to-liquid (GTL) projects are being supported by the government of Nigeria to develop the natural gas sector. Onshore and offshore exploration, surveying and geophysical prospecting, drilling equipment, facilities maintenance, deepwater E and P, equipment for LNG/GTL facilities, enhanced recovery equipment and services, gas re-injection technology, pipelines, and the refinery sector are all areas where Canadian equipment and service suppliers could benefit from opportunities in Nigeria. One of the most prominent foreign player in the Nigerian market is Royal Dutch Shell. As far as the offshore deepwater E and P sub-sector, the three major players are Shell, ChevronTexaco, and ExxonMobil. The Nigerian government advocate in upstream and downstream oil industries in the country is Nigeria National Petroleum Corporation (NNPC). The primary domestic end-users of oil and gas equipment and services are member companies of the Nigerian Association of Indigenous Petroleum Exploration Companies (NAIPEC). Canadian companies are encouraged to form joint venture partnerships in oil and gas projects, as foreign majors operating in Nigeria tend to rely on the skills and expertise of foreign

  15. Market study on the Mexican market for electrical distribution equipment

    International Nuclear Information System (INIS)

    1991-01-01

    A brief historical survey of the development of the Mexican electric power sector is presented, along with an overview of the state of the Mexican economy since the late 1980s and the present characteristics of the Mexican electricity sector. The Mexican market for electric power generation and distribution equipment is then assessed, from the perspective of Canadian suppliers and manufacturers intending to enter this market. Projected consumption of electrical generation and distribution equipment in Mexico for 1994 is estimated at US$1,035,600,000 ($719.4 million in production, $356.9 million in imports, and $40.7 million in exports). This market increased 12.3% in 1990, and since power demand in Mexico has been growing faster than growth in capacity, it is possible that investments in the electricity sector will grow at faster rates. Items which are traditionally imported include nuclear reactors and related equipment, boilers, turbines, power breakers, valves, coal and ash handling equipment, relays, automatic controls, and chemical treatment equipment. The USA has the greatest share of the import market with 35%, followed by Japan (22%), Switzerland (18%), and Germany (13%). Canadian exports have concentrated on distribution equipment and only totalled $1.7 million in 1990. Electricity is distributed to some 16.6 million users over a national interconnected system having total installed capacity of 30,513 MW in 1991. There are plans to increase capacity by 9.7 GW by 1994 and another 37.4-47.8 GW between 1995 and 2010. Projections of electricity needs by region are listed along with the new power plants targeted for investment. Market liberalization and lowering of tariffs have made the Mexican market more accessible to exporters. 8 tabs

  16. A users view of the SPS and LEP control systems

    International Nuclear Information System (INIS)

    Bailey, R.

    1992-01-01

    Every accelerator has a control system; at present the SPS has two, both of which are needed to run the machine. Consequently a user of the SPS/LEP complex has to be concurrently familiar with three control systems. While this situation brings problems it allows, even forces, comparison between the different systems, which in turn enriches the user viewpoint. This paper assesses the SPS and LEP control systems from the point of view of the user, who may be an equipment specialist, operator, accelerator physicist or combinations thereof. (author)

  17. User Frustrations as Opportunities

    Directory of Open Access Journals (Sweden)

    Michael Weiss

    2012-04-01

    Full Text Available User frustrations are an excellent source of new product ideas. Starting with this observation, this article describes an approach that entrepreneurs can use to discover business opportunities. Opportunity discovery starts with a problem that the user has, but may not be able to articulate. User-centered design techniques can help elicit those latent needs. The entrepreneur should then try to understand how users are solving their problem today, before proposing a solution that draws on the unique skills and technical capabilities available to the entrepreneur. Finally, an in-depth understanding of the user allows the entrepreneur to hone in on the points of difference and resonance that are the foundation of a strong customer value proposition.

  18. User interface support

    Science.gov (United States)

    Lewis, Clayton; Wilde, Nick

    1989-01-01

    Space construction will require heavy investment in the development of a wide variety of user interfaces for the computer-based tools that will be involved at every stage of construction operations. Using today's technology, user interface development is very expensive for two reasons: (1) specialized and scarce programming skills are required to implement the necessary graphical representations and complex control regimes for high-quality interfaces; (2) iteration on prototypes is required to meet user and task requirements, since these are difficult to anticipate with current (and foreseeable) design knowledge. We are attacking this problem by building a user interface development tool based on extensions to the spreadsheet model of computation. The tool provides high-level support for graphical user interfaces and permits dynamic modification of interfaces, without requiring conventional programming concepts and skills.

  19. The PANTHER User Experience

    Energy Technology Data Exchange (ETDEWEB)

    Coram, Jamie L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Morrow, James D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Perkins, David Nikolaus [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    This document describes the PANTHER R&D Application, a proof-of-concept user interface application developed under the PANTHER Grand Challenge LDRD. The purpose of the application is to explore interaction models for graph analytics, drive algorithmic improvements from an end-user point of view, and support demonstration of PANTHER technologies to potential customers. The R&D Application implements a graph-centric interaction model that exposes analysts to the algorithms contained within the GeoGraphy graph analytics library. Users define geospatial-temporal semantic graph queries by constructing search templates based on nodes, edges, and the constraints among them. Users then analyze the results of the queries using both geo-spatial and temporal visualizations. Development of this application has made user experience an explicit driver for project and algorithmic level decisions that will affect how analysts one day make use of PANTHER technologies.

  20. RADTRAN 4: User guide

    International Nuclear Information System (INIS)

    Neuhauser, K.S.; Kanipe, F.L.

    1992-01-01

    RADTRAN 4 is used to evaluate radiological consequences of incident-free transportation, as well as the radiological risks from vehicular accidents occurring during transportation. This User Guide is Volume 3 in a series of four volume of the documentation of the RADTRAN 4 computer code for transportation risk analysis. The other three volumes are Volume 1, the Executive Summary; Volume 2, the Technical Manual; and Volume 4, the Programmer's Manual. The theoretical and calculational basis for the operations performed by RADTRAN 4 are discussed in Volume 2. Throughout this User Guide the reader will be referred to Volume 2 for detailed discussions of certain RADTRAN features. This User Guide supersedes the document ''RADTRAN III'' by Madsen et al. (1983). This RADTRAN 4 User Guide specifies and describes the required data, control inputs, input sequences, user options, program limitations, and other activities necessary for execution of the RADTRAN 4 computer code

  1. Thermal expansion

    International Nuclear Information System (INIS)

    Yun, Y.

    2015-01-01

    Thermal expansion of fuel pellet is an important property which limits the lifetime of the fuels in reactors, because it affects both the pellet and cladding mechanical interaction and the gap conductivity. By fitting a number of available measured data, recommended equations have been presented and successfully used to estimate thermal expansion coefficient of the nuclear fuel pellet. However, due to large scatter of the measured data, non-consensus data have been omitted in formulating the equations. Also, the equation is strongly governed by the lack of appropriate experimental data. For those reasons, it is important to develop theoretical methodologies to better describe thermal expansion behaviour of nuclear fuel. In particular, first-principles and molecular dynamics simulations have been certainly contributed to predict reliable thermal expansion without fitting the measured data. Furthermore, the two theoretical techniques have improved on understanding the change of fuel dimension by describing the atomic-scale processes associated with lattice expansion in the fuels. (author)

  2. JCE Online: Equipment Buyers Guide

    Science.gov (United States)

    Holmes, Jon L.

    1999-01-01

    The Equipment Buyers Guide was edited by Jo Rita Jordan. The new Equipment Buyers Guide, bound into the back of this issue, is also a new resource of JCE Internet. This resource provides an online source for the information contained in the printed guide. Placing this information online allows us to regularly update it and to provide live links to the suppliers' WWW sites. The organization of the online version parallels that of the print version. There is an alphabetical list of suppliers and a categorical listing. Links to these lists are provided on every page in the left-hand navigation bar. To quickly find information about a particular supplier, you click Supplier List, click the letter that begins the supplier's name, and scroll through the list to find the supplier. To find which suppliers provide a particular type of instrument or equipment, use the Categories link; click the category of the equipment you are looking for and then click the link to a supplier. You will then be taken to an alphabetical supplier listing page where you can scroll until you find the particular supplier of the item for which you are looking. Once you have found a supplier, the online Equipment Buyers Guide gives you the traditional contact information. But in addition, you also get one-click access to the WWW sites of the suppliers that have them. Depending on the site, you should be able to find information about the items that you seek and may even be able to order the items online! We think that you will find the online version of the Equipment Buyers Guide useful. To make it more useful, please send your suggestions, any errors or omissions you find, and any additional categories to the editor at jjordan@world.std.com The online Equipment Buyers Guide can be found at JCE Online at http://JChemEd.chem.wisc.edu/JCEWWW/Resources/EBG/ JCE Online in '99 JCE Online is your online source of "all things JCE". In order to provide you with an even more useful online resource, JCE

  3. Division of Scientific Equipment - Overview

    International Nuclear Information System (INIS)

    Halik, J.

    2002-01-01

    Full text: The Scientific Equipment Division consists of the Design Group and the Mechanical Workshop. The activity of the Division includes the following: * designs of devices and equipment for experiments in physics; their mechanical construction and assembly. In particular, these are vacuum chambers and installations for HV and UHV;* maintenance and upgrading of the existing installations and equipment in our Institute; * participation of our engineers and technicians in design works, equipment assembly and maintenance for experiments in foreign laboratories. The Design Group is equipped with PC-computers and AutoCAD graphic software (release 2000 and Mechanical Desktop 4.0) and an A0 plotter, which allow us to make drawings and 2- and 3-dimensional mechanical documentation to the world standards. The Mechanical Workshop offers a wide range of machining and treatment methods with satisfactory tolerances and surface quality. They include: * turning - cylindrical elements of a length up to 2000 mm and a diameter up to 400 mm, and also disc type elements of a diameter up to 600 mm and a length not exceeding 300 mm, * milling - elements of length up to 1000 mm and gear wheels of diameter up to 300 mm, * grinding - flat surfaces of dimensions up to 300 mm x 1000 mm and cylindrical elements of a diameter up to 200 mm and a length up to 800 mm, * drilling - holes of a diameter up to 50 mm, * welding - electrical and gas welding, including TIG vacuum-tight welding, * soft and hard soldering, * mechanical works including precision engineering, * plastics treatment - machining and polishing using diamond milling, modelling, lamination of various shapes and materials, including plexiglas, scintillators and light-guides, * painting - paint spraying with possibility of using furnace-fired drier of internal dimensions of 800 mm x 800 mm x 800 mm. Our workshop is equipped with the CNC milling machine which can be used for machining of work pieces up to 500 kg. The machine

  4. Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

  5. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface......, and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program...

  6. Ergonomic requirements for the operation of machines and technical equipment

    Directory of Open Access Journals (Sweden)

    Górny Adam

    2017-01-01

    Full Text Available In order to operate machinery and equipment safely, it is critical for the solutions in place to conform to design-related and operating requirements. Design-related requirements are primarily the responsibility of machine designers/developers and manufacturers. Operating requirements should be satisfied by employers, who are responsible for ensuring safe working conditions for their employees. Under applicable laws, machinery and equipment should be designed, produced and then operated without placing excessive loads on workers and in keeping with machine functionality and intended use. One should also ensure that machinery and equipment can be maintained and adjusted without exposing their operators to hazards. Ergonomic criteria are an integral part of such requirements. They ensure that human users and operators of technical equipment are enabled to function properly. Design-related requirements are viewed as a priority safety consideration. While they facilitate the use of technical tools, the actual safety of employees ultimately depends on the satisfaction of specific requirements during operation.

  7. Reduction of Equipment Access Time through Cyber Plant Navigation

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Jang Soo; Goo, Ja Sung; Kim, Yong Yi [Korea Hydro and Nuclera Power Co., Daejeon (Korea, Republic of)

    2012-05-15

    Safe and effective on-the-job training at a nuclear power plant has been gaining its importance in South Korea and in the UAE. As a solution to this, a cyber plant has been developed based on 3D model design data. It allows its users to access equipment and components in a virtual reality without risks or danger of potential radiation exposure and also increases their familiarity with NPP structures. Equipped with navigation functions similar to those of the applications installed in automobiles and smart phones, this application displays the shortest route to reach the target equipment and predicts estimated access time and radiation exposure dose. This application has contributed to the reduction of equipment access time, and therefore has facilitated early response to abnormal conditions, reduced radiation exposure dose, and maximized the effects of OJT at nuclear power plants. This paper will look at the realization of the cyber plant, the operations of the cyber plant, and how cyber plant applications can be applied further

  8. Reduction of Equipment Access Time through Cyber Plant Navigation

    International Nuclear Information System (INIS)

    Suh, Jang Soo; Goo, Ja Sung; Kim, Yong Yi

    2012-01-01

    Safe and effective on-the-job training at a nuclear power plant has been gaining its importance in South Korea and in the UAE. As a solution to this, a cyber plant has been developed based on 3D model design data. It allows its users to access equipment and components in a virtual reality without risks or danger of potential radiation exposure and also increases their familiarity with NPP structures. Equipped with navigation functions similar to those of the applications installed in automobiles and smart phones, this application displays the shortest route to reach the target equipment and predicts estimated access time and radiation exposure dose. This application has contributed to the reduction of equipment access time, and therefore has facilitated early response to abnormal conditions, reduced radiation exposure dose, and maximized the effects of OJT at nuclear power plants. This paper will look at the realization of the cyber plant, the operations of the cyber plant, and how cyber plant applications can be applied further

  9. Analysis of Medium-Scale Solar Thermal Systems and Their Potential in Lithuania

    Directory of Open Access Journals (Sweden)

    Rokas Valančius

    2015-06-01

    Full Text Available Medium-scale solar hot water systems with a total solar panel area varying from 60 to 166 m2 have been installed in Lithuania since 2002. However, the performance of these systems varies depending on the type of energy users, equipment and design of the systems, as well as their maintenance. The aim of this paper was to analyse operational SHW systems from the perspective of energy production and economic benefit as well as to outline the differences of their actual performance compared to the numerical simulation results. Three different medium-scale solar thermal systems in Lithuania were selected for the analysis varying in both equipment used (flat type solar collectors, evacuated tube collectors and type of energy user (swimming pool building, domestic hot water heating, district heating. The results of the analysis showed that in the analysed cases the gap between measured and modelled data of heat energy produced by SHW systems was approx. 11%. From the economical perspective, the system with flat type solar collectors used for domestic hot water production was proved to be most efficient. However, calculation of Internal Rate of Return showed that a grant of 35% is required for this project to be fully profitable.

  10. Satellite communication from user to user

    Science.gov (United States)

    Gern, Manfred

    Satellite communication systems which allow a multitude of user-to-user, point-to-point, and multipoint connections, are presented. The bit rates are 64 kbit/sec and multiples, up to 1.92 Mbit/sec. If required, the ground-stations are installed at the customer's site or at suitable locations in order to serve several customers. However, technical requirements for station location have also to be fulfulled, in order to avoid interference with terrestrial radio services. The increasing number of participants to Satellite Multi Service and INTELSAT Business Services imposes the solution of the problem of communication using cheap techniques. The changes of the German Federal Post Office also permit the economic use of satellite radio techniques for short distances.

  11. IEEE recommended practices for seismic qualification of Class 1E equipment for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    The IEEE has developed this document to provide direction for developing programs to seismically qualify Class 1E equipment for nuclear power generating stations. It supplements IEEE Std 323-1974, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations, which describes the basic requirements for equipment qualification. The Class 1E equipment to be qualified by produres or standards established by this document are of many forms, characteristics, and materials; therefore, the document presents many acceptable methods with the intent of permitting the user to make a judicious selection from among the various options. In making such a selection, the user should choose those that best meet a particular equipment's requirements. Further, in using this document as a specification for the purchase of equipment, the many options should also be recognized and the document invoked accordingly. It is recommended that the need for specific standards for the seismic qualifiction of particular kinds of equipment be evaluated by those responsible for such documents and that consideration be given to the application of particular methods from these documents which are most suitable

  12. Glance traceability – Web system for equipment traceability and radiation monitoring for the ATLAS experiment

    CERN Document Server

    Ramos de Azevedo Evora, L H; Pommes, K; Galvão, K K; Maidantchik, C

    2010-01-01

    During the operation, maintenance, and dismantling periods of the ATLAS Experiment, the traceability of all detector equipment must be guaranteed for logistic and safety matters. The running of the Large Hadron Collider will expose the ATLAS detector to radiation. Therefore, CERN must follow specific regulations from both the French and Swiss authorities for equipment removal, transport, repair, and disposal. GLANCE Traceability, implemented in C++ and Java/Java3D, has been developed to fulfill the requirements. The system registers and associates each equipment part to either a functional position in the detector or a zone outside the underground area through a 3D graphical user interface. Radiation control of the equipment is performed using a radiation monitor connected to the system: the local background gets stored and the threshold is automatically calculated. The system classifies the equipment as non radioactive if its radiation dose does not exceed that limit value. History for both location traceabi...

  13. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    Energy Technology Data Exchange (ETDEWEB)

    Rossel, R.E., E-mail: ralf.erik.rossel@cern.ch [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Hochschule RheinMain, Fachbereich Design Informatik Medien, Wiesbaden (Germany); Fedosseev, V.N.; Marsh, B.A. [CERN, Geneva (Switzerland); Richter, D. [Hochschule RheinMain, Fachbereich Design Informatik Medien, Wiesbaden (Germany); Rothe, S. [CERN, Geneva (Switzerland); Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany); Wendt, K.D.A. [Institut für Physik, Johannes Gutenberg-Universität, Mainz (Germany)

    2013-12-15

    Highlights: • The requirements for continuous and automated RILIS operation are outlined. • Laser wavelength, power, beam position and pulse timing are continuously monitored. • A network-extended LabVIEW-based equipment operation framework was developed. • The system serves as a foundation for collaborative laser spectroscopy data acquisition. • Example applications have been successfully tested with ISOLDE experiment setups. -- Abstract: With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The system contributes to four key aspects of RILIS operation: equipment monitoring, machine protection, automated self-reliance, and collaborative data acquisition. The overall concept, technologies used, implementation status and recent applications during the 2012 on-line operation period will be presented along with a summary of future developments.

  14. LLCEDATA and LLCECALC for Windows version 1.0, Volume 1: User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    McFadden, J.G.

    1998-09-04

    LLCEDATA and LLCECALC for Windows are user-friendly computer software programs that work together to determine the proper waste designation, handling, and disposition requirements for Long Length Contaminated Equipment (LLCE). LLCEDATA reads from a variety of data bases to produce an equipment data file (EDF) that represents a snapshot of both the LLCE and the tank it originates from. LLCECALC reads the EDF and a gamma assay (AV2) file that is produced by the Flexible Receiver Gamma Energy Analysis System. LLCECALC performs corrections to the AV2 file as it is being read and characterizes the LLCE. Both programs produce a variety of reports, including a characterization report and a status report. The status report documents each action taken by the user, LLCEDATA, and LLCECALC. Documentation for LLCEDATA and LLCECALC for Windows is available in three volumes. Volume 1 is a user`s manual, which is intended as a quick reference for both LLCEDATA and LLCECALC. Volume 2 is a technical manual, and Volume 3 is a software verification and validation document.

  15. The role of original equipment manufacturers in software distribution

    Directory of Open Access Journals (Sweden)

    Herţanu, A.

    2012-01-01

    Full Text Available The software distribution channels are having a significant impact on the mix of marketing not only for big companies in this domain, but also for small companies that activate in this domain. The Original Equipment Manufacturer’s distribution channel it’s having a significant impact on the marketing strategy of different companies. If the traditional distribution channels are still used to, the OEM’s channels are used more and more to distribute the software products or services not only to the segment of consumers formed by companies, but also to the segment of costumers formed by individual users.

  16. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2001-01-01

    Full text: The activity of ZdAJ in 2000 was focused on realisation of the Government-Ordered Project - 6/15 MeV Accelerator. The realisation was accomplished in two stages: - stage I should result in deriving principal operational parameters of the accelerator - stage 2 will result in full implementation of the control system providing optimum control of the equipment and automatic maintaining of its parameters. Within the frames of the first stage, a klystron modulator panel was finished and the design documentation of the mechanical supporting structure, the arm, accelerating structure, collimator and control panel were advanced. Manufacturing of the above sub-units in the workshop has started. In the frames of the Specific Project of the State Committee for Scientific Research, the improvement of Neptun lOPC accelerator was undertaken. The read-out of the monitor dose with atmospheric pressure and ambient temperature compensation has been introduced. New filters for equalising the photon and electron beam and new wedge filters have been designed. Changes in programming have been introduced, which improve the patient's safety by eliminating possible personnel errors and increase the accuracy of radiation fields read-out. In 2000 ZdAJ progressed in development of the Quality System conforming EN-ISO 9001 Standard by including the provisions of EN 46001 Standard. The Standard EN 46001: ''Quality Systems - Medical Equipment''. Detailed requirements related to application of EN ISO 9001 is an European Quality Standard extending the provisions of EN ISO 9001 Standard over the manufacturers of medical equipment. (author)

  17. Reactor vital equipment determination techniques

    International Nuclear Information System (INIS)

    Bott, T.F.; Thomas, W.S.

    1983-01-01

    The Reactor Vital Equipment Determination Techniques program at the Los Alamos National Laboratory is discussed. The purpose of the program is to provide the Nuclear Regulatory Commission (NRC) with technical support in identifying vital areas at nuclear power plants using a fault-tree technique. A reexamination of some system modeling assumptions is being performed for the Vital Area Analysis Program. A short description of the vital area analysis and supporting research on modeling assumptions is presented. Perceptions of program modifications based on the research are outlined, and the status of high-priority research topics is discussed

  18. Thermal Properties and Thermal Analysis:

    Science.gov (United States)

    Kasap, Safa; Tonchev, Dan

    The chapter provides a summary of the fundamental concepts that are needed to understand the heat capacity C P, thermal conductivity κ, and thermal expansion coefficient α L of materials. The C P, κ, and α of various classes of materials, namely, semiconductors, polymers, and glasses, are reviewed, and various typical characteristics are summarized. A key concept in crystalline solids is the Debye theory of the heat capacity, which has been widely used for many decades for calculating the C P of crystals. The thermal properties are interrelated through Grüneisen's theorem. Various useful empirical rules for calculating C P and κ have been used, some of which are summarized. Conventional differential scanning calorimetry (DSC) is a powerful and convenient thermal analysis technique that allows various important physical and chemical transformations, such as the glass transition, crystallization, oxidation, melting etc. to be studied. DSC can also be used to obtain information on the kinetics of the transformations, and some of these thermal analysis techniques are summarized. Temperature-modulated DSC, TMDSC, is a relatively recent innovation in which the sample temperature is ramped slowly and, at the same time, sinusoidally modulated. TMDSC has a number of distinct advantages compared with the conventional DSC since it measures the complex heat capacity. For example, the glass-transition temperature T g measured by TMDSC has almost no dependence on the thermal history, and corresponds to an almost step life change in C P. The new Tzero DSC has an additional thermocouple to calibrate better for thermal lags inherent in the DSC measurement, and allows more accurate thermal analysis.

  19. Game user experience evaluation

    CERN Document Server

    Bernhaupt, Regina

    2015-01-01

    Evaluating interactive systems for their user experience (UX) is a standard approach in industry and research today. This book explores the areas of game design and development and Human Computer Interaction (HCI) as ways to understand the various contributing aspects of the overall gaming experience. Fully updated, extended and revised this book is based upon the original publication Evaluating User Experience in Games, and provides updated methods and approaches ranging from user- orientated methods to game specific approaches. New and emerging methods and areas explored include physiologi

  20. Safety for Users

    CERN Multimedia

    HR Department

    2008-01-01

    CERN welcomes more than 8000 Users every year. The PH Department as host to these scientific associates requires the highest safety standards. The PH Safety Office has published a Safety Flyer for Users. Important safety topics and procedures are presented. Although the Flyer is intended primarily to provide safety information for Users, the PH Safety Office invites all those on the CERN sites to keep a copy of the flyer as it gives guidance in matters of safety and explains what to do in the event of an emergency. Link: http://ph-dep.web.cern.ch/ph-dep/Safety/SafetyOffice.html PH-Safety Office PH Department

  1. Safety for Users

    CERN Multimedia

    HR Department

    2008-01-01

    CERN welcomes more than 8000 Users every year. The PH Department as host to these scientific associates requires the highest safety standards. The PH Safety Office has published a safety flyer for Users. Important safety topics and procedures are presented. Although the flyer is intended primarily to provide safety information for Users, the PH Safety Office invites all those on the CERN sites to keep a copy of the flyer as it gives guidance in matters of safety and explains what to do in the event of an emergency. The flyer is available at: http://ph-dep.web.cern.ch/ph-dep/Safety/SafetyOffice.html PH-Safety Office PH Department

  2. Designing for user engagement

    CERN Document Server

    Geisler, Cheryl

    2013-01-01

    Designing for User Engagement on the Web: 10 Basic Principles is concerned with making user experience engaging. The cascade of social web applications we are now familiar with - blogs, consumer reviews, wikis, and social networking - are all engaging experiences. But engagement is an increasingly common goal in business and productivity environments as well. This book provides a foundation for all those seeking to design engaging user experiences rich in communication and interaction. Combining a handbook on basic principles with case studies, it provides readers with a ric

  3. Guidelines for CubeSat's Thermal Design

    Science.gov (United States)

    Rodriguez-Ruiz, Juan; Patel, Deepak

    2015-01-01

    Thermal and Fluids Analysis Workshop 2015, Silver Spring, MD. NCTS 19104-15. What does it take to thermally designlow cost, low mass cubesats? What are the differences in the approach when you compare with large scale missions?What additional risk is acceptable? What is the approach to hardware? How is the testing campaign run? These aresome of the questions that will be addressed in this course, which is designed to equip the attendees to support thedevelopment of cubesats at their organization.

  4. Failure mechanism for thermal fatigue of thermal barrier coating systems

    Energy Technology Data Exchange (ETDEWEB)

    Giolli, C.; Scrivani, A.; Rizzi, G. [Turbocoating S.p.A., Rubbiano di Solignano (Italy); Borgioli, F. [Firenze Univ., Sesto Fiorentino (Italy); Bolelli, G.; Lusvarghi, L. [Univ. di Modena e Reggio Emilia, Modena (Italy)

    2008-07-01

    High temperature thermal fatigue causes the failure of Thermal Barrier Coating (TBC) systems. Due to the difference in thickness and microstructure between thick TBCs and traditional thin TBCs, they cannot be assumed a-priori to possess the same failure mechanisms. Thick TBCs, consisting of a CoNiCrAlY bond coat and Yttria Partially Stabilised Zirconia top coat with different values of porosity, were produced by Air Plasma Spray. Thermal fatigue resistance limit of TBCs was tested by Furnace Cycling Tests (FCT) according to the specifications of an Original Equipment Manufacturer (OEM). TBC systems were analyzed before and after FCT. The morphological and chemical evolution of CoNiCrAlY/TGO microstructure was studied. Sintering effect, residual stress, phase transformation and fracture toughness were evaluated in the ceramic Top Coat. All the tested samples passed FCT according to the specification of an important OEM. Thermal fatigue resistance increases with the amount of porosity in the top coat. The compressive in-plane stresses increase in the TBC systems after thermal cycling, nevertheless the increasing rate has a trend contrary to the porosity level of top coat. The data suggest that the spallation happens at the TGO/Top Coat interface. The failure mechanism of thick TBCs subjected to thermal fatigue was eventually found to be similar to the failure mechanism of thin TBC systems made by APS. (orig.)

  5. Performance and equipments upgrade of compact nuclear simulator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Chang; Kwon, Kee Choon; Sim, Bong Shick; Kim, Jung Taek; Lee, Dong Young; Kim, Chang Hwoi; Park, Won Man; Song, Soon Ja; Yoo, Soon Duk; Yang, Kwang Nam

    1997-12-01

    The compact nuclear simulator (CNS) is installed in the Korea Atomic Energy Research Institute (KAERI) Nuclear Training Center in 1988. The CNS has been used for training of non-operator personnel such as NSSS design engineers, maintenance personnel, inspectors of regulatory body, etc. and for test facility of fuzzy control algorithm. The CNS was manufactured by KAERI and Studsvik (now Eurosim) joint project. The CNS mathematical modeling modeled a three loop Westinghouse Pressurizer Water Reactor (PWR), 993 MWe, mostly referred to as the Kori Unit 3 and 4 in Korea. But the main computer (Micro VAX II), a interface card between main computer and operator panel, and a graphic interface system are faced with frequent troubles by obsolescence and lack of spare parts. According to the above reasons, the CNS hardware should be replaced by state of the art equipment. It is planned to replace the main computer with HP workstation, a dedicated interface card with a PLC-based interface system, and a graphic interface system with an X-terminal based full graphics system. The software for a instructor console also will be modified text-based to Motif-based user interface. The Motif-based user interface provides more efficient and easy operation in a instructor console also will be modified text-based to Motif-based user interface. The Motif-based user interface provides more efficient and easy operation in a instructor console. (author). 124 refs., 2 tabs., 24 figs

  6. The replace repair decision for heavy equipment.

    Science.gov (United States)

    2004-01-01

    The fleet of equipment operated by the Virginia Department of Transportation (VDOT) constitutes a large investment, on the order of half a billion dollars. A means of identifying earlier and more accurately those pieces of equipment whose timely repl...

  7. Proceedings of FED remote maintenance equipment workshop

    International Nuclear Information System (INIS)

    Sager, P.; Garin, J.; Hager, E.R.; Spampinato, P.T.; Tobias, D.; Young, N.

    1981-11-01

    A workshop was convened in two sessions in January and March 1981, on the remote maintenance equipment for the Fusion Engineering Device (FED). The objectives of the first session were to familiarize the participants with the status of the design of the FED and to develop a remote maintenance equipment list for the FED. The objective of the second session was to have the participants present design concepts for the equipment which had been identified in the first session. The equipment list was developed for general purpose and special purpose equipment. The general purpose equipment was categorized as manipulators and other, while the special purpose equipment was subdivided according to the reactor subsystem it serviced: electrical, magnetic, and nuclear. Both mobile and fixed base manipulators were identified. Handling machines were identified as the major requirement for special purpose equipment

  8. Musical Sound, Instruments, and Equipment

    Science.gov (United States)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  9. Distributed User Selection in Network MIMO Systems with Limited Feedback

    KAUST Repository

    Elkhalil, Khalil; Eltayeb, Mohammed E.; Dahrouj, Hayssam; Al-Naffouri, Tareq Y.

    2015-01-01

    We propose a distributed user selection strategy in a network MIMO setting with M base stations serving K users. Each base station is equipped with L antennas, where LM ≪ K. The conventional selection strategy is based on a well known technique called semi-orthogonal user selection when the zero-forcing beamforming (ZFBF) is adopted. Such technique, however, requires perfect channel state information at the transmitter (CSIT), which might not be available or need large feedback overhead. This paper proposes an alternative distributed user selection technique where each user sets a timer that is inversely proportional to his channel quality indicator (CQI), as a means to reduce the feedback overhead. The proposed strategy allows only the user with the highest CQI to respond with a feedback. Such technique, however, remains collision free only if the transmission time is shorter than the difference between the strongest user timer and the second strongest user timer. To overcome the situation of longer transmission times, the paper proposes another feedback strategy that is based on the theory of compressive sensing, where collision is allowed and all users encode their feedback information and send it back to the base-stations simultaneously. The paper shows that the problem can be formulated as a block sparse recovery problem which is agnostic on the transmission time, which makes it a good alternative to the timer approach when collision is dominant.

  10. Distributed User Selection in Network MIMO Systems with Limited Feedback

    KAUST Repository

    Elkhalil, Khalil

    2015-09-06

    We propose a distributed user selection strategy in a network MIMO setting with M base stations serving K users. Each base station is equipped with L antennas, where LM ≪ K. The conventional selection strategy is based on a well known technique called semi-orthogonal user selection when the zero-forcing beamforming (ZFBF) is adopted. Such technique, however, requires perfect channel state information at the transmitter (CSIT), which might not be available or need large feedback overhead. This paper proposes an alternative distributed user selection technique where each user sets a timer that is inversely proportional to his channel quality indicator (CQI), as a means to reduce the feedback overhead. The proposed strategy allows only the user with the highest CQI to respond with a feedback. Such technique, however, remains collision free only if the transmission time is shorter than the difference between the strongest user timer and the second strongest user timer. To overcome the situation of longer transmission times, the paper proposes another feedback strategy that is based on the theory of compressive sensing, where collision is allowed and all users encode their feedback information and send it back to the base-stations simultaneously. The paper shows that the problem can be formulated as a block sparse recovery problem which is agnostic on the transmission time, which makes it a good alternative to the timer approach when collision is dominant.

  11. User interface development

    Science.gov (United States)

    Aggrawal, Bharat

    1994-01-01

    This viewgraph presentation describes the development of user interfaces for OS/2 versions of computer codes for the analysis of seals. Current status, new features, work in progress, and future plans are discussed.

  12. SEVERO code - user's manual

    International Nuclear Information System (INIS)

    Sacramento, A.M. do.

    1989-01-01

    This user's manual contains all the necessary information concerning the use of SEVERO code. This computer code is related to the statistics of extremes = extreme winds, extreme precipitation and flooding hazard risk analysis. (A.C.A.S.)

  13. EPA User Personas

    Science.gov (United States)

    Learn how EPA's three web user personas (Information Consumer, Information Intermediary, and Information Interpreter) can help you identify appropriate top audiences and top tasks for a topic or web area.

  14. VIERS- User Preference Service

    Data.gov (United States)

    Department of Veterans Affairs — The Preferences service provides a means to store, retrieve, and manage user preferences. The service supports definition of enterprise wide preferences, as well as...

  15. AVERT User Manual

    Science.gov (United States)

    AVERT is a flexible modeling framework with a simple user interface designed specifically to meet the needs of state air quality planners and other interested stakeholders. Use this guide to get started.

  16. EMAP Users Manual.

    Science.gov (United States)

    Kotz, Arnold; Redondo, Rory

    Presented is the user's manual for the Educational Manpower Information Sources Project (EMAP), an information file containing approximately 325 document abstracts related to the field of educational planning. (The EMAP file is described in document SP 006 747.) (JB)

  17. MINTEQ user's manual

    International Nuclear Information System (INIS)

    Peterson, S.R.; Hostetler, C.J.; Deutsch, W.J.; Cowan, C.E.

    1987-02-01

    This manual will aid the user in applying the MINTEQ geochemical computer code to model aqueous solutions and the interactions of aqueous solutions with hypothesized assemblages of solid phases. The manual will provide a basic understanding of how the MINTEQ computer code operates and the important principles that are incorporated into the code and instruct a user of the MINTEQ code on how to create input files to simulate a variety of geochemical problems. Chapters 2 through 8 are for the user who has some experience with or wishes to review the principles important to geochemical computer codes. These chapters include information on the methodology MINTEQ uses to incorporate these principles into the code. Chapters 9 through 11 are for the user who wants to know how to create input data files to model various types of problems. 35 refs., 2 figs., 5 tabs

  18. Thermal comfort

    DEFF Research Database (Denmark)

    d’Ambrosio Alfano, Francesca Romana; Olesen, Bjarne W.; Palella, Boris Igor

    2014-01-01

    Thermal comfort is one of the most important aspects of the indoor environmental quality due to its effects on well-being, people's performance and building energy requirements. Its attainment is not an easy task requiring advanced design and operation of building and HVAC systems, taking...... into account all parameters involved. Even though thermal comfort fundamentals are consolidated topics for more than forty years, often designers seem to ignore or apply them in a wrong way. Design input values from standards are often considered as universal values rather than recommended values to be used...... under specific conditions. At operation level, only few variables are taken into account with unpredictable effects on the assessment of comfort indices. In this paper, the main criteria for the design and assessment of thermal comfort are discussed in order to help building and HVAC systems designers...

  19. User Effect on Code Application and Qualification Needs

    International Nuclear Information System (INIS)

    D'Auria, F.; Salah, A.B.

    2008-01-01

    Experience with some code assessment case studies and also additional ISPs have shown the dominant effect of the code user on the predicted system behavior. The general findings of the user effect investigations on some of the case studies indicate, specifically, that in addition to user effects, there are other reasons which affect the results of the calculations and are hidden under the general title of user effects. The specific characteristics of experimental facilities, i.e. limitations as far as code assessment is concerned; limitations of the used thermal-hydraulic codes to simulate certain system behavior or phenomena; limitations due to interpretation of experimental data by the code user, i.e. interpretation of experimental data base. On the basis of the discussions in this paper, the following conclusions and recommendations can be made: More dialogue appears to be necessary with the experimenters in the planning of code assessment calculations, e.g. ISPs.; User guidelines are not complete for the codes and the lack of sufficient and detailed user guidelines are observed with some of the case studies; More extensive user instruction and training, improved user guidelines, or quality assurance procedures may partially reduce some of the subjective user influence on the calculated results; The discrepancies between experimental data and code predictions are due both to the intrinsic code limit and to the so called user effects. There is a worthful need to quantify the percentage of disagreement due to the poor utilization of the code and due to the code itself. This need especially arises for the uncertainty evaluation studies (e.g. [18]) which do not take into account the mentioned user effects; A much focused investigation, based on the results of comparison calculations e.g. ISPs, analyzing the experimental data and the results of the specific code in order to evaluate the user effects and the related experimental aspects should be integral part of the

  20. Channel Characteristics and User Body Effects in an Outdoor Urban Scenario at 15 and 28 GHz

    DEFF Research Database (Denmark)

    Zhao, Kun; Gustafson, Carl; Liao, Qingbi

    2017-01-01

    The effect of a user’s body on channel characteristics for single user downlink transmission in an urban scenario for the 5th generation (5G) systems is investigated with ray-tracing at 15 GHz and 28 GHz. Three different designs of user equipment (UE) antennas are fabricated and integrated into a...

  1. Equipment available for automating rig operations

    International Nuclear Information System (INIS)

    McNair, W.L.

    1990-01-01

    Several manufacturers are producing automated rig equipment, from complete systems to individual functions for existing drilling rigs. Significant improvements in well site time, costs of operations, and improved drilling performance have led drilling contractors to install this equipment on their rigs. This paper details some of the equipment available for automating rigs

  2. 13 CFR 143.32 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Equipment. 143.32 Section 143.32...

  3. 32 CFR 33.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 32 National Defense 1 2010-07-01 2010-07-01 false Equipment. 33.32 Section 33.32 National Defense...

  4. 45 CFR 92.32 - Equipment.

    Science.gov (United States)

    2010-10-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 45 Public Welfare 1 2010-10-01 2010-10-01 false Equipment. 92.32 Section 92.32 Public Welfare...

  5. 40 CFR 31.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Equipment. 31.32 Section 31.32...

  6. 14 CFR 1273.32 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Equipment. 1273.32 Section 1273.32...

  7. 29 CFR 1470.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 29 Labor 4 2010-07-01 2010-07-01 false Equipment. 1470.32 Section 1470.32 Labor Regulations...

  8. 15 CFR 24.32 - Equipment.

    Science.gov (United States)

    2010-01-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Equipment. 24.32 Section 24.32...

  9. 38 CFR 43.32 - Equipment.

    Science.gov (United States)

    2010-07-01

    ... awarding agency. (d) Management requirements. Procedures for managing equipment (including replacement... return. (e) Disposition. When original or replacement equipment acquired under a grant or subgrant is no... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Equipment. 43.32 Section...

  10. 30 CFR 250.602 - Equipment movement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Equipment movement. 250.602 Section 250.602... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Well-Workover Operations § 250.602 Equipment movement. The movement of well-workover rigs and related equipment on and off a platform or from well to well on...

  11. 30 CFR 250.502 - Equipment movement.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Equipment movement. 250.502 Section 250.502... OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Well-Completion Operations § 250.502 Equipment movement. The movement of well-completion rigs and related equipment on and off a platform or from well to well...

  12. 46 CFR 121.220 - Cooking equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cooking equipment. 121.220 Section 121.220 Shipping... SYSTEMS AND EQUIPMENT Cooking and Heating § 121.220 Cooking equipment. (a) Doors on a cooking appliance... cooking appliance must be installed to prevent movement in heavy seas. (c) For a grill or similar type of...

  13. 46 CFR 184.220 - Cooking equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Cooking equipment. 184.220 Section 184.220 Shipping...) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Cooking and Heating § 184.220 Cooking equipment. (a) Doors on a cooking appliance must be provided with hinges and locking devices to prevent...

  14. Special equipment for etching nitrocellulose film

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1983-08-01

    Nitrocellulose film and converter screens used for neutron radiography are described. Difficulties in visualization of radiographs on those films are mentioned. Because there is no equipment for etching nitrocellulose film available on the market Risoe has designed and produced such equipment at an estimated cost of Dkr. 15,000. Design criteria for this equipment are given and its performance described

  15. Developing equipment for AGR remote visual inspection

    International Nuclear Information System (INIS)

    James, P.W.; Walton, P.J.

    1985-01-01

    The Remote Inspection Group is part of the CEGB's Generation Development and Construction Division, and has responsibility for the design, development, procurement, testing and setting to work of the equipment provided to carry out routine remote visual inspections of its AGRs. This equipment includes both the viewing devices and the necessary placement equipment. (author)

  16. 46 CFR 121.210 - Heating equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Heating equipment. 121.210 Section 121.210 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150... SYSTEMS AND EQUIPMENT Cooking and Heating § 121.210 Heating equipment. (a) Each heater must be so...

  17. 46 CFR 184.210 - Heating equipment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Heating equipment. 184.210 Section 184.210 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Cooking and Heating § 184.210 Heating equipment...

  18. 14 CFR 121.605 - Airplane equipment.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane equipment. 121.605 Section 121.605..., FLAG, AND SUPPLEMENTAL OPERATIONS Dispatching and Flight Release Rules § 121.605 Airplane equipment. No person may dispatch or release an airplane unless it is airworthy and is equipped as prescribed in § 121...

  19. Fire prevention and protection for trackless equipment

    Energy Technology Data Exchange (ETDEWEB)

    Burger, A.J.

    1988-10-01

    With the increased use of trackless diesel and electrical equipment underground, the fire danger associated with this equipment has increased. The need for adequate fire prevention and protection on all aspects of trackless mechanised mining must be taken into consideration. This paper describes briefly the causes of fires on trackless equipment and the precautions taken to reduce the risk of ignition. 1 tab.

  20. Load Bearing Equipment for Bone and Muscle

    Science.gov (United States)

    Shackelford, Linda; Griffith, Bryan

    2015-01-01

    Resistance exercise on ISS has proven effective in maintaining bone mineral density and muscle mass. Exploration missions require exercise with similar high loads using equipment with less mass and volume and greater safety and reliability than resistance exercise equipment used on ISS (iRED, ARED, FWED). Load Bearing Equipment (LBE) uses each exercising person to create and control the load to the partner.

  1. Matrix thermalization

    International Nuclear Information System (INIS)

    Craps, Ben; Evnin, Oleg; Nguyen, Kévin

    2017-01-01

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  2. Matrix thermalization

    Science.gov (United States)

    Craps, Ben; Evnin, Oleg; Nguyen, Kévin

    2017-02-01

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  3. Matrix thermalization

    Energy Technology Data Exchange (ETDEWEB)

    Craps, Ben [Theoretische Natuurkunde, Vrije Universiteit Brussel (VUB), and International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium); Evnin, Oleg [Department of Physics, Faculty of Science, Chulalongkorn University, Thanon Phayathai, Pathumwan, Bangkok 10330 (Thailand); Theoretische Natuurkunde, Vrije Universiteit Brussel (VUB), and International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium); Nguyen, Kévin [Theoretische Natuurkunde, Vrije Universiteit Brussel (VUB), and International Solvay Institutes, Pleinlaan 2, B-1050 Brussels (Belgium)

    2017-02-08

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  4. AIR CONTAMINANT EXPOSURE DURING THE OPERATION OF LAWN AND GARDEN EQUIPMENT

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) initiated the Small Engine Exposure Study (SEES) to evaluate potential exposures among users of small, gasoline-powered, non-road spark-ignition (SI) lawn and garden engines. Equipment tested included riding tractors, walk-behind la...

  5. Study to Analyze the Acquisition of Automatic Test Equipment (ATE) Systems. Data Sequence Number A003

    Science.gov (United States)

    1973-12-27

    Systems Test Equipment Comparator, ASTEC ) at NAEC can provide a very accurate Ion a pin by pin basis) match between the UUT and ATE in their data bank...In addition, abbreviated summary data on the ATE is also available to users. ASTEC will also file the UUT data as part of its data bank so that

  6. Prior use of durable medical equipment as a risk adjuster for health-based capitation

    NARCIS (Netherlands)

    R.C. van Kleef (Richard); R.C.J.A. van Vliet (René)

    2010-01-01

    textabstractThis paper examines a new risk adjuster for capitation payments to Dutch health plans, based on the prior use of durable medical equipment (DME). The essence is to classify users of DME in a previous year into clinically homogeneous classes and to apply the resulting classification as a

  7. 47 CFR 2.803 - Marketing of radio frequency devices prior to equipment authorization.

    Science.gov (United States)

    2010-10-01

    ... advised in writing at the time of the offer for sale that the equipment is subject to the FCC rules and... authority of a local FCC licensed service provider. However, the licensee must grant permission to the... party has the product measured to ensure compliance at the end user's location, the product does not...

  8. Metadata: A user`s view

    Energy Technology Data Exchange (ETDEWEB)

    Bretherton, F.P. [Univ. of Wisconsin, Madison, WI (United States); Singley, P.T. [Oak Ridge National Lab., TN (United States)

    1994-12-31

    An analysis is presented of the uses of metadata from four aspects of database operations: (1) search, query, retrieval, (2) ingest, quality control, processing, (3) application to application transfer; (4) storage, archive. Typical degrees of database functionality ranging from simple file retrieval to interdisciplinary global query with metadatabase-user dialog and involving many distributed autonomous databases, are ranked in approximate order of increasing sophistication of the required knowledge representation. An architecture is outlined for implementing such functionality in many different disciplinary domains utilizing a variety of off the shelf database management subsystems and processor software, each specialized to a different abstract data model.

  9. Radiological security of portable equipment used in the industry

    International Nuclear Information System (INIS)

    Cateriano, M.A.

    2006-01-01

    The industrial meters with encapsulated sources are used intensely in the present time due to the economic benefits that generate. Their use in all the one world has been reflected in an improvement of the quality of the analyzed product and of one optimization of the production process, allowing to carry out these measurements and controls without interrupting the process and in non destructive form generating an energy saving in turn and of materials. Although these industrial meters are intrinsically safe for design in the portable meters their safety also is strongly governed in the strict pursuit of procedures and in the adequate personnel's training that operate these equipment. In the Argentine Republic in 2005 the Nuclear Regulatory Authority (RNA) had registered a quantity of 160 portable equipment. In the period 1995-2003, 2 incidents took place with these equipment one of them used to measure soils humidity of Troxler trademark containing a source of Am-241(Be) of 370 MBq and the remaining one also of Troxler trademark used to measure density and humidity of soils containing 2 sources of Cs-137 of 296 MBq and Am-241(Be) of 1.48 GBq respectively. The incidents were developed without relevant radiological implications had taken place. In this work those mentioned incidents are analyzed in order to determining the causes that originated the same ones, for this way to be able to elaborate recommendations with the purpose of to correct errors and to diminish the recurrence probability improving the safety in the use of these equipment. From the analyses of these incidents result that should put on more emphasis in the personnel training and the invigoration of the safety culture in the use of the industrial meters. Also a present panorama of the inventory of equipment, sources and users that possess these portable meters in the Argentine Republic is also presented. (Author)

  10. Establishment for Nuclear Equipment -Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2006-01-01

    Research and development works conducted in the Establishment for Nuclear Equipment (ZdAJ) were focused around 3 subject areas: an accelerator for cancer treatment, therapeutical tables, systems and methods for controlling objects that cross international borders. The new, medium energy accelerator for cancer therapy cases is being designed in the Establishment for several years. In 2005 progress was achieved. A physical part, containing an electron beam has been completed and the parameters of that beam make it useful for therapeutical purposes. Consequently, the work on designing and testing of beam control systems, ensuring its high stability, repetition of irradiation parameters and accuracy of dosage have been started. Results of these tests make it very probable that 2006 will be the final year of scientific works and in 2007 the new apparatus will be ready for sales. Therapeutical tables have become a leading product of ZdAJ IPJ. Their technical parameters, reliability and universality in uses are appreciated by many customers of ZdAJ. In 2005, the table Polkam 16 was registered by the national Office for Registration of Medical Equipment as the first product of ZdAJ that meets all technical and formal requirements of the safety mark CE. This allows sales of the product on the market of the European Union. The research and development part of designing a therapeutical table for uses in the total body irradiation technique was also concluded in 2005. After the September 11 terrorist attacks on WTC a matter of controlling international borders have become a priority for many countries. In 2005 in ZdAJ IPJ, we conducted many preliminary calculations and experiments analyzing systems of irradiation sources, both photon and neutron as well as systems of detection and designing of signals triggered by controlling objects crossing the border. The results so far have enabled us to formulate a research project which has been positively evaluated by experts and found

  11. Communication equipment radiation resistance ensurance

    International Nuclear Information System (INIS)

    Myrova, L.O.; Chelizhenko, A.Z.

    1983-01-01

    A review of works on radiation resistance of electronic equipment (epsilon epsilon) for 15 years is presented. The effect of ionizing radiation appearing as a result of nuclear explosions in nuclear facilities and in outerspace on epsilon epsilon has been considered. Types of radiation effects in epsilon epsilon, radiation effect on semiconductor devices and integrated circUits, types of epsilon epsilon failures, as well as the procass of radiation-resistant epsilon epsilon designing and selection of its main parameters have been described. The methods of epsilon epsilon flowsheet optimization, application of mathematical simulation and peculiarities of ensurance of epsilon epsilon radiation resistance of communication systems are considered. Peculiarities of designing of radiation-resistant quartz generators, secondary power supply sources and amplifiers are discussed

  12. Purex: process and equipment performance

    International Nuclear Information System (INIS)

    Orth, D.A.

    1986-01-01

    The Purex process is the solvent extraction system that uses tributyl phosphate as the extractant for separating uranium and plutonium from irradiated reactor fuels. Since the first flowsheet was proposed at Oak Ridge National Laboratory in 1950, the process has endured for over 30 years with only minor modifications. The spread of the technology was rapid, and worldwide use or research on Purex-type processes was reported by the time of the 1955 Geneva Conference. The overall performance of the process has been so good that there are no serious contenders for replacing it soon. This paper presents: process description; equipment performance (mixer-settlers, pulse columns, rapid contactors); fission product decontamination; solvent effects (solvent degradation products); and partitioning of uranium and plutonium

  13. Automation of a thermogravimetric equipment

    International Nuclear Information System (INIS)

    Mussio, L.; Castiglioni, J.; Diano, W.

    1987-01-01

    A low cost automation of some instruments by means of simple electronic circuits and a microcomputer Apple IIe. type is discussed. The electronic circuits described are: a) a position detector including phototransistors connected as differential amplifier; b) a current source that, using the error signal of the position detector, changes the current through the coil of an electromagnetic balance to restore its zero position; c) a proportional temperature controller, zero volt switching to drive a furnace to a desired temperature; d) an interface temperature regulator-microcomputer to control the temperature regulator by software; e) a multiplexer for an analog input of a commercial interface. Those circuits are applied in a thermogravimetric equipment used also for vapours adsorption. A program in block diagram form is included and is able to record change of mass, time, furnace temperature and to drive the temperature regulator in order to have the heating rates or the temperature plateaux needed for the experiment. (author) [pt

  14. Establishment for Nuclear Equipment: Overview

    International Nuclear Information System (INIS)

    Pracz, J.

    2000-01-01

    Full text: The main objective of the activity of the Establishment for Nuclear Equipment (ZdAJ) in 1999 was to obtain the ISO 9001 certificate. Work on this problem has been successfully completed. The changes introduced in agreement with requirements of ISO in supervising the construction, manufacturing and servicing eliminate possible deficiencies of our products and will pay in the future. Two new important ventures have been undertaken: design of an accelerator with two photon energies and a reconstruction of simulator directed towards better geometrical parameters. The completion of the improvements in accelerator is foreseen for the year 2002. The changes comprise almost all sub-assemblies of the device. The modernized simulator will be installed in the hospital already in the year 2000 - the ameliorations concern mainly the arm of the apparatus, collimator, driving gears and control system. Of course - apart from this, the routine production activity of the Establishment was continued in 1999. (author)

  15. Vault Safety and Inventory System users manual, PRIME 2350. Revision 1

    International Nuclear Information System (INIS)

    Downey, N.J.

    1994-01-01

    This revision is issued to request review of the attached document: VSIS User Manual, PRIME 2350, which provides user information for the operation of the VSIS (Vault Safety and Inventory System). It describes operational aspects of Prime 2350 minicomputer and vault data acquisition equipment. It also describes the User's Main Menu and menu functions, including REPORTS. Also, system procedures for the Prime 2350 minicomputer are covered

  16. Protective equipment use among female rugby players.

    Science.gov (United States)

    Comstock, R Dawn; Fields, Sarah K; Knox, Christy L

    2005-07-01

    Our objective was to assess the prevalence of protective equipment use and the motivation for using protective equipment among a sample of US female rugby players. We surveyed a convenience sample of 234 current US female rugby players from 14 teams participating in a US women's rugby tournament, obtaining self-reported demographic, rugby exposure, and protective equipment use information. Mouthguards were the most commonly used piece of protective equipment: 90.8% of players reported having always worn a mouthguard while playing or practicing rugby within their most recent 3 months of play. Fewer than 15% of players reported having always worn other types of protective equipment. Equipment use varied by playing position. Whereas over 80% of players in all other positions always wore a mouthguard, 66.7% of scrum halves reported always wearing one. Both backs and forwards reported wearing shoulder pads, but only forwards reported always wearing padded headgear. Mouthguards, padded headgear, and shoulder pads were worn "to prevent injury," whereas ankle braces, neoprene sleeves, and athletic tape on joints were worn "to protect a current/recent injury." This is the first study of female rugby players to assess the prevalence of protective equipment use by playing position and the motivation for using protective equipment. With the exception of mouthguards, US female rugby players infrequently use protective equipment. Protective equipment use varies by playing position. Some types of protective equipment appear to be used as primary prevention mechanisms, whereas others are used as secondary or tertiary prevention mechanisms.

  17. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    CERN Document Server

    Rossel, R E; Richter, D; Wendt, K D A; Rothe, S; Marsh, B A

    2013-01-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The syst...

  18. Changing nature of equipment and parts qualification

    International Nuclear Information System (INIS)

    Bucci, R.M.

    1988-01-01

    Ideally, the original supplier of a piece of nuclear safety-related equipment has performed a qualification program and will continue to support that equipment throughout the lifetime of the nuclear power plants in which in equipment is installed. The supplier's nuclear quality assurance program will be maintained and he will continue to offer all necessary replacement parts. These parts will be identical to the original parts, certified to the original purchase order requirements, and the parts will be offered at competitive prices. Due to the changing nature of the nuclear plant equipment market, however, one or more of those ideal features are frequently unavailable when safety-related replacement equipment or parts are required. Thus, the process of equipment and parts qualification has had to adjust in order to ensure obtaining qualified replacements when needed. This paper presents some new directions taken in the qualification of replacement equipment and parts to meet changes in the marketplace

  19. Free-world microelectronic manufacturing equipment

    Science.gov (United States)

    Kilby, J. S.; Arnold, W. H.; Booth, W. T.; Cunningham, J. A.; Hutcheson, J. D.; Owen, R. W.; Runyan, W. R.; McKenney, Barbara L.; McGrain, Moira; Taub, Renee G.

    1988-12-01

    Equipment is examined and evaluated for the manufacture of microelectronic integrated circuit devices and sources for that equipment within the Free World. Equipment suitable for the following are examined: single-crystal silicon slice manufacturing and processing; required lithographic processes; wafer processing; device packaging; and test of digital integrated circuits. Availability of the equipment is also discussed, now and in the near future. Very adequate equipment for most stages of the integrated circuit manufacturing process is available from several sources, in different countries, although the best and most widely used versions of most manufacturing equipment are made in the United States or Japan. There is also an active market in used equipment, suitable for manufacture of capable integrated circuits with performance somewhat short of the present state of the art.

  20. 9 CFR 590.502 - Equipment and utensils; PCB-containing equipment.

    Science.gov (United States)

    2010-01-01

    ... Sanitary Standards and accepted practices currently in effect for such equipment. (c) New or replacement equipment or machinery (including any replacement parts) brought onto the premises of any official plant... equipment and machinery, and any replacement parts for such equipment and machinery. Totally enclosed...