  1. Performance test of nutrient control equipment for hydroponic plants

    Science.gov (United States)

    Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.

    2017-11-01

    Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.

  2. Test strategies for industrial testers for converter controls equipment

    International Nuclear Information System (INIS)

    Oleniuk, P.; Kasampalis, V.; Cosmo, M. Di; Nisbet, D.; Todd, B.; Uznański, S.

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.

  3. submitter Test strategies for industrial testers for converter controls equipment

    CERN Document Server

    Oleniuk, P; Kasampalis, V; Nisbet, D; Todd, B; Uznański, S

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary s...

  4. Equipment for accelerated tests of bearings for reactor control system linear electromagnet drives

    International Nuclear Information System (INIS)

    Voskobojnikov, V.V.; Semchenko, Eh.L.; Usov, P.P.; Nikolaev, V.P.

    1989-01-01

    Specific operation of friction units in reactor control system linear electromagnet drives is considered. Installation for determining specific electromagnetic forces, applied to bearings of reactor control system drives, and equipment for wear tests of friction pairs are described. The considered equipment permits to study characteristics of promising materials of friction pairs, to determine their wear resistance and operating longevity, that much reduces tests cost and time

  5. Analysis and application of electromagnetic compatibility test for safety instrumentation and control electronic equipment

    International Nuclear Information System (INIS)

    Hu Xuefeng; Zhou Liang; Zhang Longqiang

    2014-01-01

    The applicable qualification standard of electromagnetic compatibility (EMC) tests for instrumentation and control electronic equipment was introduced. The electromagnetic interference immunity test, the radiated radio-frequency electromagnetic field immunity test, the sensibility test, the source surge immunity test and the electrostatic discharge immunity test for EMC test were mainly introduced. And the important of configuration and the selection of method for EMC sampler was especially introduced. (authors)

  6. Evaluation tests of the Instrumentation and Control equipment to use in nuclear power plants: its contribution to the improvement and quality certification of the Brazilian equipment

    International Nuclear Information System (INIS)

    Menezes, R.H.M. de; Peluso, M.A.V.

    1984-01-01

    This work presents the procedures used to evaluate Instrumentation Control equipment and reports the experience of integration among instrument user, manufacturer and test institution. It covers tests for equipments for conventional user and for specific application in Nuclear Power Stations. (Author) [pt

  7. Intelligent cruise control field operational test. Vol III, Performance of a string or cluster of ACC-equipped cars

    Science.gov (United States)

    1998-07-01

    This report is one element of a cooperative agreement between NHTSA and UMTRI entitled Intelligent Cruise Control (ICC) Field Operational Test (FOT). It addresses the operation of a serial string or dense cluster of passenger cars equipped with a new...

  8. SCTE: An open-source Perl framework for testing equipment control and data acquisition

    Science.gov (United States)

    Mostaço-Guidolin, Luiz C.; Frigori, Rafael B.; Ruchko, Leonid; Galvão, Ricardo M. O.

    2012-07-01

    SCTE intends to provide a simple, yet powerful, framework for building data acquisition and equipment control systems for experimental Physics, and correlated areas. Via its SCTE::Instrument module, RS-232, USB, and LAN buses are supported, and the intricacies of hardware communication are encapsulated underneath an object oriented abstraction layer. Written in Perl, and using the SCPI protocol, enabled instruments can be easily programmed to perform a wide variety of tasks. While this work presents general aspects of the development of data acquisition systems using the SCTE framework, it is illustrated by particular applications designed for the calibration of several in-house developed devices for power measurement in the tokamak TCABR Alfvén Waves Excitement System. Catalogue identifier: AELZ_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AELZ_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License Version 3 No. of lines in distributed program, including test data, etc.: 13 811 No. of bytes in distributed program, including test data, etc.: 743 709 Distribution format: tar.gz Programming language: Perl version 5.10.0 or higher. Computer: PC. SCPI capable digital oscilloscope, with RS-232, USB, or LAN communication ports, null modem, USB, or Ethernet cables Operating system: GNU/Linux (2.6.28-11), should also work on any Unix-based operational system Classification: 4.14 External routines: Perl modules: Device::SerialPort, Term::ANSIColor, Math::GSL, Net::HTTP. Gnuplot 4.0 or higher Nature of problem: Automation of experiments and data acquisition often requires expensive equipment and in-house development of software applications. Nowadays personal computers and test equipment come with fast and easy-to-use communication ports. Instrument vendors often supply application programs capable of controlling such devices, but are very restricted in terms of

  9. The use of fuzzy logic in quality control testing of automotive and tractor equipment

    Directory of Open Access Journals (Sweden)

    Korobko А.

    2016-08-01

    Full Text Available The article analyzes the relevance of the research topics, defines goals and objectives, subject and object of research. On the basis of the literature analysis, the following eduction was made: not all the test methods in road and agricultural vehicles (tractors contribute to the effective implementation of the requirements of normative documents including international, inter-laboratory comparative tests. The approach in laboratory testing to the synthesis adaptive system of metrological assurance the use of fuzzy logic is proposed. These labs conduct testing of automotive and tractor equipment. The decision is under risk. The scheme of metrological assurance system covers all parties to ensure the necessary accuracy of measurements and tests; the necessary normative-technical documentation is provided; availability of measuring instruments and test equipment, standards and reference measures; availability of qualified personnel; the assurance that test results are accurate (correct and precision; provides effective decisions based on objective information.

  10. Nuclear electronic equipment for control and monitoring panel. Specifications and methods for testing radiation detectors

    International Nuclear Information System (INIS)

    Roguin, Andre.

    1976-02-01

    This document will be of interest to users and makers of neutron and gamma radiations detectors in the field of nuclear reactor control and protection. Information is given which will enable users to optimize their choice and methods of using equipment, and makers to optimize their methods of fabrication. It should also serve as a model from which official specifications, technical instructions and test methods for these detectors, could be established. A detailed description is given of the appropriate parameters, terminology and notations. General specifications, operating conditions and test methods are indicated. The following detectors are studied: in-core detectors: fission ionization chambers, self powered neutron detectors (S.P.N.D.); out-core detectors: boron ionization chambers (for monitoring), boron trifluoride proportional counter tubes, boron lined proportional counter tubes, helium-3 proportional counter tubes. The devices described in the document are intended for industrial radiation monitoring applications and not for calibration standards (dosimetry) or for health physics measurement purposes. They are characterized by their fidelity, fast response, reliability and long lifetimes [fr

  11. Test Equipment Specifications Transistor

    OpenAIRE

    Didiek Andiana Ramadan; Drs. Linga Hermanto, MMSI Drs. Linga Hermanto, MMSI

    2005-01-01

    In this paper, we design a test apparatus Transistor Specification. Specification is atype of transistor is a transistor and common emitter current reinforcement value ( βDC ). The system will provide information in the form of an LED display emits greenlight when the tested types of NPN transistor and the second LED emits blue lightwhen the tested types of PNP transistors.To test the value of β, whose value is proportional to the display used by the collectorcurrent Ic.

  12. Equipment fragility testing

    International Nuclear Information System (INIS)

    Holman, G.S.; Chou, C.K.; Cummings, G.E.

    1985-01-01

    Current probabilistic risk assessment (PRA) methods for nuclear power plants utilize component fragilities which are for the most part based on a limited data base and engineering judgement. The seismic design of components is based on code limits and NRC requirements that do not reflect the actual capacity of a component to resist failure. In order to improve the present component fragility data base and establish component seismic design margins, the NRC has commissioned a projected three-year program to compile existing fragilities data and at the same time independently perform fragilities tests on selected mechanical and electrical components. This paper presents the planning and technical approach being taken by LLNL in the NRC Component Fragility Program

  13. Nuclear electronic equipment for control and monitoring panel. Procedure guide for on-site tests of nuclear reactor instruments

    International Nuclear Information System (INIS)

    1975-10-01

    By the use of a procedure for on-site testing of nuclear reactor instruments it should be possible to judge their ability to guarantee the reactor safety and availability at the moment of divergence or during operation. Such a procedure must therefore be created as a work implement for the quick and reliable installation of electronic devices necessary for nuclear reactor control and supervision. A standard document is proposed for this purpose, allowing a ''test programme'' to be set up before the equipment is installed on the site [fr

  14. Quality control of equipment

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    The information obtained from all diagnostic nuclear medicine procedures is based on the assumption that the performance of the instruments used for data acquisition, display and analysis are highly reliable and accurate. Once received and installed, the instrument should be put to a series of acceptance tests designed to establish whether its initial performance confirms with the manufacturers specifications. Simultaneously, reference test should be done against which its subsequent performance ca be checked by routine testing (daily, weekly, monthly, quarterly and yearly). Careful records of the result of all these tests should be maintained for further action. Such quality control (QC) test does not however obviate the need for the preventive maintenance procedures, which shall be carried out on a regular basis. (author)

  15. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  16. Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.

    Science.gov (United States)

    Pernstich, K P

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.

  17. The use of fuzzy logic in quality control testing of automotive and tractor equipment

    OpenAIRE

    Korobko А.; Mykhailova О.; Nazarko О.; Radchenko Yu.

    2016-01-01

    The article analyzes the relevance of the research topics, defines goals and objectives, subject and object of research. On the basis of the literature analysis, the following eduction was made: not all the test methods in road and agricultural vehicles (tractors) contribute to the effective implementation of the requirements of normative documents including international, inter-laboratory comparative tests. The approach in laboratory testing to the synthesis adaptive system of metrological a...

  18. The main tests for quality control in X-ray equipment of radiodiagnosis

    International Nuclear Information System (INIS)

    Ferreira, R.S.

    1988-01-01

    All aspects of the relation between patient, examination and diagnosis for controling the quality in radiodiagnosis are showed. The bundle collimation for decreasing the scattered radiation in patient and the systems for measuring the exposure time are described. The yield valuation and the tension for X-rays tube are also cited. (C.G.C.) [pt

  19. Characterization of a PET-NEMA/IEC body phantom for quality control tests of PET/CT equipment

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Vieira, Igor F.; Lima, Fernando R.A.; Sa, Lidia V. de

    2011-01-01

    The Brazilian Sanitary Agency from Ministry of Health requires that all PET/CT equipment must undergo minimal quality control tests using manufacturer simulators. The PET-NEMA/IEC body phantom is recommended by the IEC and NEMA to perform acceptance testing and quality control in PET/CT equipment according to specific protocols. It is essential that all simulator components (spheres and body) are properly characterized in relation to their size and internal structure volumes, since they are used to calculate the overall activity concentration and the total weight. The objective of this work was characterize a PET-NEMA/IEC body phantom for the true reconstruction in computational modeling and correct analysis of experimental results. The simulator is basically composed of three structures: the body (simulating a portion of the chest), an inner cylinder (simulating the lung tissue) and a top cover in which are coupled spheres of different sizes simulating 'hot' (tumors) and cold lesions. The spheres were evaluated in terms of volume. The same evaluations were performed with the body of the simulator and the inner cylinder, beyond of analysis of their weights (filled with water) and wall thickness. The data showed that the total weight of the simulator with all its internal structures is 12.5 kg and the volume of the 'hot' and 'cold' spheres are approximately equal to those presented by the manufacturer. The inner cylinder volume showed a significant difference between the measured and the presented in the manual. The results were used for reconstruction of the simulator in computational modeling using the code GATE. (author)

  20. Testing of FFTF fuel handling equipment

    International Nuclear Information System (INIS)

    Coleman, D.W.; Grazzini, E.D.; Hill, L.F.

    1977-07-01

    The Fast Flux Test Facility has several manual/computer controlled fuel handling machines which are exposed to severe environments during plant operation but still must operate reliably when called upon for reactor refueling. The test programs for two such machines--the Closed Loop Ex-Vessel Machine and the In-Vessel Handling Machine--are described. The discussion centers on those areas where design corrections or equipment repairs substantiated the benefits of a test program prior to plant operation

  1. Use of automated test equipment and open-quotes paperlessclose quotes process control to implement efficient production of SSC dipole magnets

    International Nuclear Information System (INIS)

    Tobin, T.; Fagan, R.; Mitchell, D.

    1994-01-01

    In an effort to minimize human error and maximize process control and test capabilities during Collider Dipole Magnets (CDM) production, General Dynamics is developing automated test and process control equipment; known as Test ampersand Process Control Modules (TPCM's). When used along with software designed to create open-quotes paperlessclose quotes process control documentation, the system becomes the Test ampersand Process Control System (TPCS). This system simplifies business decisions and eliminates some problems normally associated with process control documentation, while reducing human errors during CDM production. It is also designed to reduce test operator errors normally incurred during test setup and data analysis. The authors present an overview of the TPCS hardware and software being developed at General Dynamics, along with the process control techniques included in TPCS

  2. Automatic system of tests for control equipment in combined cycle power stations; Sistema automatico de pruebas para equipos de control en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Flores L, Zenon; Delgadillo V, Miguel A; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    This article deals on the Automatic System of Tests, denominated PROBADOR, used by the Gerencia de Control e Instrumentation (GCI) of the Instituto de Investigaciones Electricas (IIE)for the accomplishment of dynamic tests in laboratory, to the systems of acquisition and control developed with the electronic line SAC-IIE that are installed in the Thermoelectric Power station of Combined Cycle (CTCC) of Dos Bocas, Veracruz and Gomez Palacio, Durango, Mexico. Also the architecture, the functions that are carried out in the equipment of the System of Acquisition and control (SAC) and in the personal computer (PC) that conforms it are described, as well as the methodology used for the development of the tests. The PC constitutes Interface Man-Machine (IMM) and in the SAC equipment the simulation of the processes is made (by means of the execution of algebraic-differential equations) in the compressor, combustion chamber, gas turbine, heat recuperators, steam turbines and condenser equipment that integrate a CTCC. The equations that are used are based in the thermodynamics, flow dynamics and heat transfer; they become attached to the real process with a margin of error that is estimated in 10%. Finally, the tendencies of the PROBADOR and the technical and economic advantages are described that it has provided for the improvement in the performance of the control systems, before different situations, with no need to have the real process. [Spanish] Este articulo versa sobre el Sistema Automatico de Pruebas, denominado PROBADOR, utilizado por la Gerencia de Control e Instrumentacion (GCI) del Instituto de Investigaciones Electricas para la realizacion de pruebas dinamicas en laboratorio, a los sistemas de adquisicion y control desarrollado con la linea electronica SAC-IIE que estan instalados en las Centrales Termoelectricas de Ciclo Combinado (CTCC) de Dos Bocas, Veracruz y Gomez Palacio, Durango, Mexico. Tambien se describen la arquitectura, las funciones que se llevan

  3. Imaging Sensor Flight and Test Equipment Software

    Science.gov (United States)

    Freestone, Kathleen; Simeone, Louis; Robertson, Byran; Frankford, Maytha; Trice, David; Wallace, Kevin; Wilkerson, DeLisa

    2007-01-01

    The Lightning Imaging Sensor (LIS) is one of the components onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, and was designed to detect and locate lightning over the tropics. The LIS flight code was developed to run on a single onboard digital signal processor, and has operated the LIS instrument since 1997 when the TRMM satellite was launched. The software provides controller functions to the LIS Real-Time Event Processor (RTEP) and onboard heaters, collects the lightning event data from the RTEP, compresses and formats the data for downlink to the satellite, collects housekeeping data and formats the data for downlink to the satellite, provides command processing and interface to the spacecraft communications and data bus, and provides watchdog functions for error detection. The Special Test Equipment (STE) software was designed to operate specific test equipment used to support the LIS hardware through development, calibration, qualification, and integration with the TRMM spacecraft. The STE software provides the capability to control instrument activation, commanding (including both data formatting and user interfacing), data collection, decompression, and display and image simulation. The LIS STE code was developed for the DOS operating system in the C programming language. Because of the many unique data formats implemented by the flight instrument, the STE software was required to comprehend the same formats, and translate them for the test operator. The hardware interfaces to the LIS instrument using both commercial and custom computer boards, requiring that the STE code integrate this variety into a working system. In addition, the requirement to provide RTEP test capability dictated the need to provide simulations of background image data with short-duration lightning transients superimposed. This led to the development of unique code used to control the location, intensity, and variation above background for simulated lightning strikes

  4. Weight/balance portable test equipment

    International Nuclear Information System (INIS)

    Whitlock, R.W.

    1994-01-01

    This document shows the general layout, and gives a part description for the weight/balance test equipment. This equipment will aid in the regulation of the leachate loading of tanker trucks. The report contains four drawings with part specifications. The leachate originates from lined trenches

  5. Reduction of patient doses in X-ray diagnosis using quality control tests on image and equipment

    International Nuclear Information System (INIS)

    Milu, C.; Tomulescu, V.; Sorescu, Anca; Vladareanu, M.; Olteanu, B.; Enachescu, B.; Zaharia, N.; Lesaru, M.

    1997-01-01

    In the frame of a research program under the contract with the International Atomic Energy Agency (IAEA), several patient dose measurements were performed using thermoluminescent dosemeters (TLDs) before and after application of Quality Control tests and patient dose reduction methods. The paper evidenced the practical influence factors (like the need of use of high voltage technique) and possibilities for dose reduction keeping the image quality. (authors)

  6. Nuclear electronic equipment for control and monitoring boards. Specifications and test methods of direct current period meters

    International Nuclear Information System (INIS)

    Roquefort, Henri; Chapelot; Ramard; Tardif; Tournier; Vaux

    1973-11-01

    After a few words of introduction, mention of the main notations used and the definition of certain terms, the field of application of the document is outlined and a list of references given. The main specifications of electronic 'direct current period meter' subassemblies for the monitoring, control and safety of nuclear reactors are then defined and the corresponding test methods described. The apparatus measures on a logarithmic scale the neutron fluence rate of a reactor by means of an ionisation chamber and supplies 'period' data relative to the fluence rate variation in time. The specifications and test methods are given for the different components: logarithmic amplifier, time derivative unit, threshold releases, high tension supply for ionisation chamber, auxiliary circuits and finally the complete period meter. (author) [fr

  7. WP EMPLACEMENT CONTROL AND COMMUNICATION EQUIPMENT DESCRIPTIONS

    International Nuclear Information System (INIS)

    Raczka, N.T.

    1997-01-01

    The objective and scope of this document are to list and briefly describe the major control and communication equipment necessary for waste package emplacement at the proposed nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the required equipment are explained and summarized in the individual subsections of this document. This task was evaluated in accordance with QAP-2-0 and found not to be quality affecting. Therefore, this document was prepared in accordance with NAP-MG-012. The following control and communication equipment are addressed in this document: (1) Programmable Logic Controllers (PLC's); (2) Leaky Feeder Radio Frequency Communication Equipment; (3) Slotted Microwave guide Communication Equipment; (4) Vision Systems; (5) Radio Control Equipment; and (6) Enclosure Cooling Systems

  8. LESSONS LEARNED IN TESTING OF SAFEGUARDS EQUIPMENT

    International Nuclear Information System (INIS)

    Pepper, S.; Farnitano, M.; Carelli, J.; Hazeltine, J.; Bailey, D.

    2001-01-01

    The International Atomic Energy Agency's (IAEA) Department of Safeguards uses complex instrumentation for the application of safeguards at nuclear facilities around the world. Often, this equipment is developed through cooperation with member state support programs because the Agency's requirements are unique and are not met by commercially available equipment. Before approving an instrument or system for routine inspection use, the IAEA subjects it to a series of tests designed to evaluate its reliability. In 2000, the IAEA began to observe operational failures in digital surveillance systems. In response to the observed failures, the IAEA worked with the equipment designer and manufacturer to determine the cause of failure. An action plan was developed to correct the performance issues and further test the systems to make sure that additional operational issues would not surface later. This paper addresses the steps taken to address operation issues related to digital image surveillance systems and the lessons learned during this process

  9. 40 CFR 85.2233 - Steady state test equipment calibrations, adjustments, and quality control-EPA 91.

    Science.gov (United States)

    2010-07-01

    ... continuing the test until HC levels drop below 20 ppm. (2) Automatic zero and span. The analyzer conducts an automatic zero and span check prior to each test. The span check must include the HC, CO, and CO2 channels... adjustment range of the analyzer, it must lock out from testing. (3) Low flow. The system locks out from...

  10. Lessons learned in testing of Safeguards equipment

    International Nuclear Information System (INIS)

    Pepper, Susan; Farnitano, Michael; Carelli, Joseph

    2001-01-01

    Upgrade Travel Funding' - This subtask provides funding for the upgrade of DIS equipment installed in the field; E.125.3, 'DIS Radiation Field Characterization' - This subtask provides for the procurement by the IAEA of radiation measurement equipment and technical assistance for the characterization of radiation conditions in the locations where DIS will be installed. This will help the IAEA ensure that the design specifications for the equipment are consistent with the location where the instrument will be used; E.125.4, 'DIS Design Limit Testing and Advise to Strengthen IAEA's Current Equipment Qualification Criteria' - Under this subtask, Wyle Laboratories and Quanterion Solutions will conduct SDIS design limit testing, including harsh environmental testing and accelerated aging, to determine the expected lifetime and produce a design limit report to include maximum operating environment vs. design limit analysis. Additionally, this task will include the development of a strengthened environmental qualification test plan and reliability and maintainability definition methodology for all safeguards equipment. The implementation of new equipment by the Department of Safeguards is costly. Expected costs associated with the implementation of equipment include capital costs, training and in some cases travel. The cost is dramatically increased when operational issues arise due to the costs of studying the issues, modifying and upgrading the equipment and additional travel. The U.S. Support Program believes that the IAEA's Division of Safeguards Technical Support (SGTS) must strengthen its equipment-testing program to ensure that the equipment it approves for inspection use is reliable and will not place additional burden on the Department of Safeguards' maintenance and inspection staff. The U.S. Support Program recognizes that SGTS already requires a series of fundamentally important and revealing tests, but we believe that additional tests should be added to the testing

  11. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  12. The design and manufacture of the catalyst test equipment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J. H.; Song, I. T. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-02-01

    The object of this report is to design and manufacture of the catalyst test equipment for removing tritium(H3) included in heavy water for the heavy water reactor. The design conditions of the reactor with the test equipment are summarized as follows 1) Flow rate : 336 l/min. 2) Pressure : 1.15kg/cm{sup 2}. 3) Maximum Temperature : 80 deg C. The test equipment is composed of the water jacket reactor, water equilibrator, heaters, condensers, tanks and pumps. As well as, it is composed of the water, hydrogen, helium, vacuum, emergency operation and control systems. This report will be used important data for the design and manufacture of the equipment for removing tritium. 30 tabs. (Author)

  13. Automatic dose-rate controlling equipment

    International Nuclear Information System (INIS)

    Szasz, T.; Nagy Czirok, Cs.; Batki, L.; Antal, S.

    1977-01-01

    The patent of a dose-rate controlling equipment that can be attached to X-ray image-amplifiers is presented. In the new equipment the current of the photocatode of the image-amplifier is led into the regulating unit, which controls the X-ray generator automatically. The advantages of the equipment are the following: it can be simply attached to any type of X-ray image-amplifier, it accomplishes fast and sensitive regulation, it makes possible the control of both the mA and the kV values, it is attached to the most reliable point of the image-transmission chain. (L.E.)

  14. Development of automatic Ultrasonic testing equipment for reactor pressure vessel

    International Nuclear Information System (INIS)

    Kim, Kor R.; Kim, Jae H.; Lee, Jae C.

    1996-06-01

    The selected weld areas of a reactor pressure vessel and adjacent piping are examined by the remote mechanized ultrasonic testing (MUT) equipment. Since the MUT equipment was purchased from southwest Research Institute (SwRI) in April 1985, 15 inservice inspections and 5 preservice inspections are performed with this MUT equipment. However due to the old age of the equipment and frequent movements to plant sites, the reliability of examination was recently decreased rapidly and it is very difficult to keep spare parts. In order to resolve these problems and to meet the strong request from plant sites, we intend to develop a new 3-axis control system including hardware and software. With this control system, we expect more efficient and reliable examination of the nozzle to shell weld areas, which is specified in ASME Code Section XI. The new 3-axis control system hardware and software were designed and development of our own control system, the advanced technologies of computer control mechanism were established and examination reliability of the nozzle to shell weld area was improved. With the development of our 3-axis control system for PaR ISI-2 computer control system, the reliability of nozzle to shell weld area examination has been improved. The established technologies from the development and detailed analysis of existing control system, are expected to be applied to the similar control systems in nuclear power plants. (author). 12 refs., 4 tabs., 33 figs

  15. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar

    International Nuclear Information System (INIS)

    Porto Junior, Almir Carlos Soares

    2014-01-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009 th by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  16. Diagnosis - Using automatic test equipment and artificial intelligence expert systems

    Science.gov (United States)

    Ramsey, J. E., Jr.

    Three expert systems (ATEOPS, ATEFEXPERS, and ATEFATLAS), which were created to direct automatic test equipment (ATE), are reviewed. The purpose of the project was to develop an expert system to troubleshoot the converter-programmer power supply card for the F-15 aircraft and have that expert system direct the automatic test equipment. Each expert system uses a different knowledge base or inference engine, basing the testing on the circuit schematic, test requirements document, or ATLAS code. Implementing generalized modules allows the expert systems to be used for any different unit under test. Using converted ATLAS to LISP code allows the expert system to direct any ATE using ATLAS. The constraint propagated frame system allows for the expansion of control by creating the ATLAS code, checking the code for good software engineering techniques, directing the ATE, and changing the test sequence as needed (planning).

  17. Robust control investigations for equipment loaded panels

    DEFF Research Database (Denmark)

    Aglietti, G.S.; Langley, R.S.; Rogers, E.

    1998-01-01

    This paper develops a modelling technique for equipment load panels which directly produces (adequate) models of the underlying dynamics on which to base robust controller design/evaluations. This technique is based on the use of the Lagrange's equations of motion and the resulting models are ver...... are verified against those produced by a finite Element Method Model...

  18. Development of automatic ultrasonic testing equipment for reactor pressure vessel

    International Nuclear Information System (INIS)

    Jang, Kee Ok; Park, Dae Yung; Park, Moon Hoh; Koo, Kil Mo; Park, Kwang Heui; Kang, Sang Sin; Bang, Heui Song; Noh, Heui Choong; Kong, Woon Sik

    1994-08-01

    The selected weld areas of reactor pressure vessel and adjacent piping are examined by remote mechanized ultrasonic testing(MUT) equipment. Since the MUT equipment was purchased from Southwest Research Institute (SwRI) in April 1985, we have performed 15 inservice inspections and 5 preservice inspections. However, the reliability of examination was recently decreased rapidly as the problems which results from the old age of equipment and the frequent movement to plant site to site have occurred frequently. Therefore, the 3-axis control system hardware in occurring many problems among the equipments of mechanized ultrasonic testing (MUT) was designed and developed to cover the examination areas of nozzle-shell weld as specified in ASME Code Section XI and to improve the examination reliability. The new 3-axis control system hardware with the performance of this project was developed to be compatible with the old one and it was used as dual system or spare parts of the old system. Furthermore, the established technologies are expected to be applied to the similar control systems in nuclear power plant. 17 figs, 2 pix, 2 tabs, 10 refs. (Author)

  19. Specification and acceptance testing of nuclear medicine equipment

    International Nuclear Information System (INIS)

    Wegst, A.V.; Erickson, J.J.

    1984-01-01

    The purchase of nuclear medicine equipment is of prime importance in the operation of a clinical service. Failure to properly evaluate the potential uses of the instrumentation and the various operational characteristics of the equipment can often result in the purchase of inappropriate or inferior instruments. The magnitude of the purchase in terms of time and financial investments make it imperative that the purchase be approached in a systematic manner. Consideration of both the intended clinical functions and personnel requirements is important. It is necessary also to evaluate the ability of the equipment vendor to support the instrumentation after the purchase has been completed and the equipment installed in the clinical site. The desired specifications of the instrument characteristics should be stated in terms that can be verified by acceptance testing. The complexity of modern instrumentation and the sensitivity of it to the environment require the buyer to take into account the potential problems of controlling the temperature, humidity, and electrical power of the installation site. If properly and systematically approached, the purchase of new nuclear medicine instrumentation can result in the acquisition of a powerful diagnostic tool which will have a useful lifetime of many years. If not so approached, it may result in the expenditure of a large amount of money and personnel time without the concomitant return in useful clinical service. (author)

  20. Operation control equipment for BWR type reactor

    International Nuclear Information System (INIS)

    Izumi, Masayuki; Takeda, Renzo.

    1981-01-01

    Purpose: To improve the temperature balance in a feedwater heater by obtaining the objective value of a feedwater enthalpy upon calculation of respective measured values and controlling the opening or closing of an extraction valve so that the objective value may coincide with the measured value, thereby averaging the axial power distribution. Constitution: A plurality of stages of extraction lines are connected to a turbine, and extraction valves are respectively provided at the lines. By calculating the measured values of ractor pressure, reactor core flow rate, vapor flow rate and reactor core inlet enthalpy determined to predetermined value using heat balance the objective feedwater enthalpy is obtained, is fed as an extraction valve opening or closing signal from a control equipment, the extraction stages of the turbine extraction are altered in accordance with this signal, and the feedwater enthalpy is controlled. (Sekiya, K.)

  1. High Temperature Calcination - MACT Upgrade Equipment Pilot Plant Test

    Energy Technology Data Exchange (ETDEWEB)

    Richard D. Boardman; B. H. O& #39; Brien; N. R. Soelberg; S. O. Bates; R. A. Wood; C. St. Michel

    2004-02-01

    About one million gallons of acidic, hazardous, and radioactive sodium-bearing waste are stored in stainless steel tanks at the Idaho Nuclear Technology and Engineering Center (INTEC), which is a major operating facility of the Idaho National Engineering and Environmental Laboratory. Calcination at high-temperature conditions (600 C, with alumina nitrate and calcium nitrate chemical addition to the feed) is one of four options currently being considered by the Department of Energy for treatment of the remaining tank wastes. If calcination is selected for future processing of the sodium-bearing waste, it will be necessary to install new off-gas control equipment in the New Waste Calcining Facility (NWCF) to comply with the Maximum Achievable Control Technology (MACT) standards for hazardous waste combustors and incinerators. This will require, as a minimum, installing a carbon bed to reduce mercury emissions from their current level of up to 7,500 to <45 {micro}g/dscm, and a staged combustor to reduce unburned kerosene fuel in the off-gas discharge to <100 ppm CO and <10 ppm hydrocarbons. The staged combustor will also reduce NOx concentrations of about 35,000 ppm by 90-95%. A pilot-plant calcination test was completed in a newly constructed 15-cm diameter calciner vessel. The pilot-plant facility was equipped with a prototype MACT off-gas control system, including a highly efficient cyclone separator and off-gas quench/venturi scrubber for particulate removal, a staged combustor for unburned hydrocarbon and NOx destruction, and a packed activated carbon bed for mercury removal and residual chloride capture. Pilot-plant testing was performed during a 50-hour system operability test January 14-16, followed by a 100-hour high-temperature calcination pilot-plant calcination run January 19-23. Two flowsheet blends were tested: a 50-hour test with an aluminum-to-alkali metal molar ratio (AAR) of 2.25, and a 50-hour test with an AAR of 1.75. Results of the testing

  2. Noise control of radiological monitoring equipment

    International Nuclear Information System (INIS)

    Rubick, R.D.; Stevens, W.W.; Burke, L.L.

    1998-01-01

    Although vacuum pumps on continuous air monitors (CAMs) do not produce noise levels above regulatory limits, engineering controls were used to establish a safer work environment. Operations performed in areas where CAMs are located are highly specialized and require precision work when handling nuclear materials, heavy metals, and inert gases. Traditional methods for controlling noise such as enclosing or isolating the source and the use of personal protection equipment were evaluated. An innovative solution was found by retrofitting CAMs with air powered multistage ejectors pumps. By allowing the air to expand in several chambers to create a vacuum, one can eliminate the noise hazard altogether. In facilities with adequate pressurized air, use of these improved ejector pumps may be a cost-effective replacement for noisy vacuum pumps. A workplace designed or engineered with noise levels as low as possible or as close to background adds to increased concentration, attention to detail, and increased production

  3. Measurement and control system for ITER remote maintenance equipment

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Kiyoshi; Kakudate, Satoshi; Takeda, Nobukazu; Takiguchi, Yuji; Akou, Kentaro [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-04-01

    ITER in-vessel components such as blankets and divertors are categorized as scheduled maintenance components because they are subjected to severe plasma heat and particle loads. Blanket maintenance requires remote handling equipment and tools able to handle Heavy payloads of about 4 tons within a 2 mm precision tolerance. Divertor maintenance requires remote replacement of 60 cassettes with a dead weight of about 25 tons each. In the ITER R and D program, full-scale remote handling equipment for blanket and divertor maintenance has been designed and assembled for demonstration tests. This paper reviews the measurement and control system developed for full-scale remote handling equipment, the Japan Home Team contribution. (author)

  4. K-Basins debris removal equipment - test plan

    International Nuclear Information System (INIS)

    Pitkoff, C.C.

    1995-01-01

    An undetermined amount of debris remains in the K-Basins which must be removed. Due to the different types of debris that will be removed, a variety of tools will be required to complete this project. This test plan gives s broad scope of the requirements that will be used for testing equipment for K-Basin debris removal. The equipment tested will be used in a radioactive environment. The equipment tested will be used to retrieve, cut, clean, and package debris from both K West and K East Basins. Testing is typically divided into six primary categories: development testing, acceptance testing, qualification testing, pre-operational testing, operational testing, and production/process testing

  5. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  6. Electromagnetic compatibility for the control and command equipments in nuclear power plants

    International Nuclear Information System (INIS)

    Buisson, J.

    1985-06-01

    Different kinds of electrical interference produce some disturbance on electronic sub-assemblies used to assume the control and the command of nuclear reactors. Following interferences are described: power supply lines perturbations, potential difference between grounding connections, electromagnetic fields. A method is described for testing the EMC of different equipments. The advantages of this method are: no destructive method, usable for testing equipment ''in situ'' in operating conditions on nuclear power plant, usable for testing equipment before operating conditions (acceptance test), level of the testing signals similar to the electrical interference level induced by the electromagnetic environment in normal operating conditions, no particular equipment and installation for test are required [fr

  7. 40 CFR 82.160 - Approved equipment testing organizations.

    Science.gov (United States)

    2010-07-01

    ... equipment testing and the technical experience of the organization's personnel. (3) Thorough knowledge of.... (5) The organization must have no conflict of interest and receive no direct or indirect financial...

  8. CFC and HFC recycling equipments: Test performances

    International Nuclear Information System (INIS)

    Picini, P.; Caropreso, G.; Cicoli, G.; Posarelli, M.

    1996-12-01

    Actual regulatory conditions about ozone layer depleting chemicals set problems on their disposal and on the management of plants still using illegal CFCs. Anyway fluids that will replace CFCs (i.e. HFCs) will not be allowed to be spread into the atmosphere, due to their high costs and to the greenhouse effect. A viable solution would be the recovery, purification and recycle of contaminated fluids. ENEA (National Agency for New Technology, Energy and the Environment), in cooperation with ICF (Industria Componenti Frigoriferi) Company leader in the field of air refrigerating and conditioning, patented a device able to extract, to clean and to recycle CFC 12 and HFC 134a in the refrigerating systems. This paper presents experimental data from the qualification tests on a device performing the above mentioned operations regarding systems that use HFC 134a as process fluid

  9. Shaking table testing of electrical equipment in Argentina

    International Nuclear Information System (INIS)

    Carmona, J.S.; Zabala, F.; Santalucia, J.; Sisterna, C.; Magrini, M.; Oldecop, L.

    1995-01-01

    This paper describes the testing facility, the methodology applied and the results obtained in the seismic qualification tests of different types of electric equipment. These tests were carried out on a shaking table that was developed and built at the Earthquake Research Institute of the National University of San Juan, Argentine. The equipment tested consist of 500 KV and 132 KV current transformers, a 500 KV voltage transformer, a 145 KV disconnecter and a relay cabinet. The acceleration response of the tested equipment was measured at several locations distributed along its height, and strains were measured at critical points by strain gauges cemented on the base of the porcelain insulator. All the information was recorded with a data acquisition system at a sampling rate of 200 times per second in each channel. The facility developed at this Institute is the largest one in operation in Argentina at present and the equipment tested is the highest, heaviest and more slender one which has been seismically qualified on a shaking table in this country. These tests have been a valuable experience in the field of structural dynamic testing applied to equipment of hydroelectric and nuclear power plants. (author)

  10. Method and equipment for treating waste water resulting from the technological testing processes of NPP equipment

    International Nuclear Information System (INIS)

    Radulescu, M. C.; Valeca, S.; Iorga, C.

    2016-01-01

    Modern methods and technologies coupled together with advanced equipment for treating residual substances resulted from technological processes are mandatory measures for all industrial facilities. The correct management of the used working agents and of the all wastes resulted from the different technological process (preparation, use, collection, neutralization, discharge) is intended to reduce up to removal of their potential negative impact on the environment. The high pressure and temperature testing stands from INR intended for functional testing of nuclear components (fuel bundles, fuelling machines, etc.) were included in these measures since the use of oils, demineralized water chemically treated, greases, etc. This paper is focused on the method and equipment used at INR Pitesti in the chemical treatment of demineralized waters, as well as the equipment for collecting, neutralizing and discharging them after use. (authors)

  11. Control of hydrogen sulfide emission from geothermal power plants. Volume III. Final report: demonstration plant equipment descriptions, test plan, and operating instructions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, F.C.; Harvey, W.W.; Warren, R.B.

    1977-01-01

    The elements of the final, detailed design of the demonstration plant for the copper sulfate process for the removal of hydrogen sulfide from geothermal steam are summarized. Descriptions are given of all items of equipment in sufficient detail that they can serve as purchase specifications. The process and mechanical design criteria which were used to develop the specifications, and the process descriptions and material and energy balance bases to which the design criteria were applied are included. (MHR)

  12. Process plant equipment operation, control, and reliability

    CERN Document Server

    Holloway, Michael D; Onyewuenyi, Oliver A

    2012-01-01

    "Process Plant Equipment Book is another great publication from Wiley as a reference book for final year students as well as those who will work or are working in chemical production plants and refinery…" -Associate Prof. Dr. Ramli Mat, Deputy Dean (Academic), Faculty of Chemical Engineering, Universiti Teknologi Malaysia "…give[s] readers access to both fundamental information on process plant equipment and to practical ideas, best practices and experiences of highly successful engineers from around the world… The book is illustrated throughout with numerous black & white p

  13. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    Energy Technology Data Exchange (ETDEWEB)

    J. Cunningham and J. Shank

    2004-11-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner.

  14. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    International Nuclear Information System (INIS)

    Cunningham, J.; Shank, J.

    2004-01-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner

  15. Automaton of on-line control system equipment performance diagnostics at a meson factory linac

    International Nuclear Information System (INIS)

    Gritsyna, O.Ya.; Kiselev, Yu.V.; Zamanskij, G.B.

    1985-01-01

    Test hardware intended for the performance monitoring the meson factory linear accelerator on-line control system specialized equipment is described. Specialized equipment comprises interfaces, input/output devices and synchronization devices. The test hardware considered allows to automate the monitoring process and reduce by more than 4 times the time required for it. Examining of methods used for diagnostics demonstrated their high reliability

  16. Equipment qualification testing methodology research at Sandia Laboratories

    International Nuclear Information System (INIS)

    Jeppesen, D.

    1983-01-01

    The Equipment Qualification Research Testing (EQRT) program is an evolutionary outgrowth of the Qualification Testing Evaluation (QTE) program at Sandia. The primary emphasis of the program has been qualification methodology research. The EQRT program offers to the industry a research-oriented perspective on qualification-related component performance, as well as refinements to component testing standards which are based upon actual component testing research

  17. Operability test procedure [Tank] 241-SY-101 equipment removal system

    International Nuclear Information System (INIS)

    Mast, J.C.

    1994-01-01

    The 241-SY-101 equipment removal system (ERS) consists of components, equipment, instrumentation and procedures that will provide the means to disconnect, retrieve, contain, load and transport the Mitigation Pump Assembly (MPA) from waste Tank 241-SY-101 to the Central Waste Complex (CWC). The Operability Test Procedure (OTP) will test the interfaces between ERS components and will rehearse the procedure for MPA removal and transportation to the extent they can be mocked-up at the CTF (Cold Test Facility). At the conclusion of the OTP, the ERS components and equipment will be removed from the CTF, entered into the Component Based Recall System (CBRS), and stored until needed for actual MPA removal and transportation

  18. High level radioactive waste vitrification process equipment component testing

    International Nuclear Information System (INIS)

    Siemens, D.H.; Heath, W.O.; Larson, D.E.; Craig, S.N.; Berger, D.N.; Goles, R.W.

    1985-04-01

    Remote operability and maintainability of vitrification equipment were assessed under shielded-cell conditions. The equipment tested will be applied to immobilize high-level and transuranic liquid waste slurries that resulted from plutonium production for defense weapons. Equipment tested included: a turntable for handling waste canisters under the melter; a removable discharge cone in the melter overflow section; a thermocouple jumper that extends into a shielded cell; remote instrument and electrical connectors; remote, mechanical, and heat transfer aspects of the melter glass overflow section; a reamer to clean out plugged nozzles in the melter top; a closed circuit camera to view the melter interior; and a device to retrieve samples of the glass product. A test was also conducted to evaluate liquid metals for use in a liquid metal sealing system

  19. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  20. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  1. Ballooning test equipment for use in hot cells

    International Nuclear Information System (INIS)

    Broendsted, P.; Adrian, F.

    1979-12-01

    An equipment for testing the LOCA behaviour of irradiated cladding materials is described. The details of the construction and of the installation in the Hot Cells are reported. Pilot tests carried out showed that the performance of the system fulfills the basic experimental prerequisites, which were: heating rate of 2-3degC/s, final temperature 1150degC/s, internal pressure max. 30 atm, external pressure max. 1 atm, test atmosphere either air or steam. (author)

  2. METHODOLOGICAL PROBLEMS AND WAYS OF CREATION OF THE AIRCRAFT EQUIPMENT TEST AUTOMATED MANAGEMENT SYSTEM

    Directory of Open Access Journals (Sweden)

    Vladimir Michailovich Vetoshkin

    2017-01-01

    Full Text Available The development of new and modernization of existing aviation equipment specimens of different classes are ac- companied and completed by the complex process of ground and flight tests. This phase of aviation equipment life cycle is implemented by means of organizational and technical systems - running centers. The latter include various proving grounds, measuring complex and systems, aircraft, ships, security and flight control offices, information processing laborato- ries and many other elements. The system analysis results of development challenges of the automated control systems of aviation equipment tests operations are presented. The automated control systems are in essence an automated data bank. The key role of development of flight tests automated control system in the process of creation of the automated control sys- tems of aviation equipment tests operations is substantiated. The way of the mobile modular measuring complexes integra- tion and the need for national methodologies and technological standards for database systems design concepts are grounded. Database system, as a central element in this scheme, provides collection, storing and updating of values of the elements described above in pace and the required frequency of the controlled object state monitoring. It is database system that pro- vides the supervisory unit with actual data corresponding to specific moments of time, which concern the state processes, assessments of the progress and results of flight experiments, creating the necessary environment for aviation equipment managing and testing as a whole. The basis for development of subsystems of automated control systems of aviation equip- ment tests operations are conceptual design processes of the respective database system, the implementation effectiveness of which largely determines the level of success and ability to develop the systems being created. Introduced conclusions and suggestions can be used in the

  3. 77 FR 10291 - Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment

    Science.gov (United States)

    2012-02-21

    ... rule include updating references to industry test procedures to their current versions, incorporating... sensors and controls, and allowing testing of certain commercial refrigeration equipment at the lowest.... Updated References to Industry Test Procedures to Their Most Current Versions 2. Inclusion of a Method for...

  4. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  5. Evaluation of field test equipment for halide and DOP testing

    International Nuclear Information System (INIS)

    Schreiber, K.L.; Kovach, J.L.

    1975-01-01

    The Nucon Testing Services Department, field testing at power reactor sites, has performed tests using R-11, R-12, and R-112 in conjunction with gas chromatographs and direct reading halide detectors. The field operational experience with these detector systems, thus sensitivity, precision, and manner of field calibration, are presented. Laboratory experiments regarding 3 H-tagged methyl iodide for in place leak testing of adsorber systems indicate a low hazard, high reliability process for leak testing in facilities where atmospheric cross contamination occurs. (U.S.)

  6. Performance of the standard FAIR equipment controller prototype

    International Nuclear Information System (INIS)

    Rauch, S.; Baer, R.C.; Panschow, W.; Thieme, M.

    2012-01-01

    For the control system of the new FAIR accelerator facility a standard equipment controller, the Scalable Control Unit (SCU), is presently under development. First prototypes have already been tested in real applications. The controller combines an *86 COM Express TM Board and an Altera Arria TM II FPGA. Over a parallel bus interface called the SCU bus, up to 12 slave boards can be controlled. Communication between CPU and FPGA is done by a PCIe link. We discuss the real time behaviour between the Linux OS and the FPGA Hardware. For the test, a Front-End Software Architecture (FESA) class, running under Linux, communicates with the PCIe bridge in the FPGA. Although we are using PCIe only for single 32 bit wide accesses to the FPGA address space, the performance still seems sufficient. The tests showed an average response time to IRQs of 50 μs with a 1.6 GHz Intel Atom CPU. This includes the context change to the FESA user space application and the reply back to the FPGA. Further topics are the bandwidth of the PCIe link for single/burst transfers and the performance of the SCU bus communication. (authors)

  7. Dynamic tension testing equipment for paperboard and corrugated fiberboard

    Science.gov (United States)

    W. D. Godshall

    1965-01-01

    The objective of this work was to develop a method, the testing equipment, and the instrumentation with which dynamic stress-strain information may be obtained for paperboards and built-up corrugated fiberboards as used in corrugated fiberboard containers. Much information is available on the properties of these materials when subjected to static or low rates of...

  8. 40 CFR 91.304 - Test equipment overview.

    Science.gov (United States)

    2010-07-01

    ... non-dispersive infrared detector (NDIR) absorption type for carbon monoxide and carbon dioxide... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Test equipment overview. 91.304 Section 91.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  9. 40 CFR 90.304 - Test equipment overview.

    Science.gov (United States)

    2010-07-01

    ... are a non-dispersive infrared (NDIR) absorption type for carbon monoxide and carbon dioxide analysis... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Test equipment overview. 90.304 Section 90.304 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  10. Methodically finding solutions of equipments for carrying out experiments in materials testing and research. Pt. 2

    International Nuclear Information System (INIS)

    Findeisen, D.; Nachtweide, D.; Kuntze, G.

    1983-01-01

    In comparison with the development of industrial products the development of test equipments is of special kind, which is demonstrated by methodical proceeding for finding solutions and by potentialities for technical design and production of test equipment engineering. Some general principles are turned out and explained by several realized examples of design belonging to the sphere of materials testing in den Federal Institute of Materials Testing (BAM) representative of other problems. User are large scientific institutes independent of university, scientific institutes as members of university just as test stands and quality control offices of industrial works. (orig.) [de

  11. Project W320 52-inch diameter equipment container load test: Test report

    International Nuclear Information System (INIS)

    Bellomy, J.R.

    1995-01-01

    This test report summarizes testing activities and documents the results of the load tests performed on-site and off-site to structural qualify the 52-inch equipment containers designed and fabricated under Project W-320

  12. Test Control Center (TCC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Test Control Center (TCC) provides a consolidated facility for planning, coordinating, controlling, monitoring, and analyzing distributed test events. ,The TCC...

  13. Regulation on control systems tests

    International Nuclear Information System (INIS)

    Grau, J.; Navarro, J.M.

    1978-01-01

    Requirements under regulation applicable to the testing of control systems and controlled equipments in the case of USA nuclear projects are examined. They are reviewed, in particular, the following standards and criteria: 10 Code of Federal Regulations 50, Appendix A, General Design Criteria 20 and 21; IEEE Standards 279 and 308; IEEE Standard 338; US Regulatory Guides 1.22 and 1.118.(J.E.de C.)

  14. Equipment to Support Development of Neuronal Network Controlled Robots

    Science.gov (United States)

    2016-06-25

    growth and training of neuronal neural networks to control robot arms. This work was done to learn the properties of the neurons and neuronal network , by...Equipment to Support Development of Neuronal Network Controlled Robots With this award, our team purchased an ALA 2-channel stimulus generator, an...peer-reviewed journals: Number of Papers published in non peer-reviewed journals: Final Report: Equipment to Support Development of Neuronal Network

  15. Improved control rod drive handling equipment for BWRs [boiling-water reactors]: Final report

    International Nuclear Information System (INIS)

    Turner, A.P.L.; Gorman, J.A.

    1987-08-01

    Improved equipment for removing and replacing control rod drives (CRDs) in BWR plants has been designed, built and tested. Control rod drives must be removed from the reactor periodically for servicing. Removal and replacement of CRDs using equipment originally supplied with the plant has long been recognized as one of the more difficult and highest radiation exposure maintenance operations that must be performed at BWR plants. The improved equipment was used for the first time at Quad Cities, Unit 2, during a Fall 1986 outage. The trial of the equipment was highly successful, and it was shown that the new equipment significantly improves CRD handling operations. The new equipment significantly simplifies the sequence of operations required to lower a CRD from its housing, upend it to a horizontal orientation, and transport it out of the reactor containment. All operations of the new equipment are performed from the undervessel equipment handling platform, thus, eliminating the requirement for a person to work on the lower level of the undervessel gallery which is often highly contaminated. Typically, one less person is required to operate the equipment than were used with the older equipment. The new equipment incorporates a number of redundant and fail safe features that improve operations and reduce the chances for accidents

  16. Program outline of seismic fragility capacity tests on nuclear power plant equipment

    International Nuclear Information System (INIS)

    Lijima, T.; Abe, H.; Fujita, T.

    2004-01-01

    A seismic probabilistic safety assessment (PSA) is an available method to evaluate residual risk of nuclear plant that is designed with definitive seismic design condition. Seismic fragility capacity data are necessary for seismic PSA, but we don't have sufficient data of active components of nuclear plants in Japan. This paper describes a plan of seismic fragility capacity tests on nuclear power plant equipment. The purpose of those tests is to obtain seismic fragility capacity of important equipment from a safety design point of view. And the equipment for the fragility capacity tests were selected considering effect on core damage frequency (CDF) that was evaluated by our preliminary seismic PSA. Consequently horizontal shaft pump, electric cabinets, Control Rod Drive system (CRD system) of BWR and PWR plant and vertical shaft pump were selected. The seismic fragility capacity tests are conducted from phase-1 to phase-3, and horizontal shaft pump and electric cabinets are tested on phase-1. The fragility capacity test consists of two types of tests. One is actual equipment test and another is element test. On actual equipment test, a real size model is tested with high-level seismic motion, and critical acceleration and failure mode are investigated. Regarding fragility test phase-1, we selected typical type horizontal shaft pump and electric cabinets for the actual equipment test. Those were Reactor Building Closed Cooling Water (RCW) Pump and eight kinds of electric cabinets such as relay cabinet, motor control center. On the test phase-1, maximum input acceleration for the actual equipment test is intended to be 6-G-force. Since the shaking table of TADOTSU facility did not have capability for high acceleration, we made vibration amplifying system. In this system, amplifying device is mounted on original shaking table and it moves in synchronization with original table. The element test is conducted with many samples and critical acceleration, median and

  17. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2003-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  18. Design of special purpose equipment - remote control dozer

    International Nuclear Information System (INIS)

    Aprameyan, K.

    1990-01-01

    Operation environment in handling hot slag, radio active material, clearing/dismantling buildings and loose rocky zones pose hazards with the operation of heavy duty vehicles. Under such hazardous environment conditions, elimination of operator becomes the prime criteria. Remote control of heavy vehicles is resorted to operate the equipment in various working conditions. Radio control systems coupled with penumatic/hydraulic actuators and proportional control logics aim total control of the equipment from a distance using hand pendants. Bharat Earth Moovers Limited has successfully developed remote control system for dozers of 200hp and 300hp. (author). 3 figs

  19. An equipment test for grading lumber by transverse vibration technique

    Directory of Open Access Journals (Sweden)

    Marcelo Rodrigo Carreira

    2008-08-01

    Full Text Available Due to the great variability of its mechanical properties, the rational use of lumber for structural purposes is directly conditioned to its grading. There are several techniques available for grading structural lumber. The most relevant one is the transverse vibration technique which obtained reliable results in non-destructive evaluation of lumber. The purpose of this work is to present the bases for the mechanical grading of lumber and the results of the calibration test of the frst transverse vibration equipment developed in Brazil. In this research 30 beams of cupiúba (Goupia glabra with nominal dimensions of 5 cm X 10 cm X 300 cm, were used. The tests were accomplished at the Wood and Timber Structures Laboratory (LaMEM of the University of São Paulo (USP. The results showed a strong correlation between the elasticity modulus measured by the static bending test and the one obtained with the transverse vibration equipment, showing the high reliability of the vibration method for the grading of structural lumber. A determination coeffcient (R² of 0.896 was obtained with the Brazilian equipment, showing that it can be used in the grading of lumber.

  20. Regulation EM-GT-7. Quality control of the radiography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    The purpose of this document is to provide practical guidance of technical procedures for carrying out quality control in X-ray equipment. This guide is applicable to general purpose radiography equipment, although some of the procedures may be applied to other types of diagnostic imaging equipment. The tests described require the appointed instrumentation and some of these can be implemented in the radiodiagnostic given the simplicity of them and others require special equipment and can be performed by external specialized groups to these units.

  1. Development of ultrasonic testing equipment incorporating electromagnetic acoustic transducer

    International Nuclear Information System (INIS)

    Sato, Michio; Kimura, Motohiko; Okano, Hideharu; Miyazawa, Tatsuo; Nagase, Koichi; Ishikawa, Masaaki

    1989-01-01

    An ultrasonic testing equipment for use in in-service inspection of nuclear power plant piping has been developed, which comprises an angle-beam electromagnetic acoustic transducer mounted on a vehicle for scanning the piping surface to be inspected. The transducer functions without direct contact with the piping surface through couplant, and the vehicle does not require a guide track installed on the piping surface, being equipped with magnetic wheels that adhere to the piping material, permitting it to travel along the circumferential weld joint of a carbon steel pipe. The equipment thus dispenses with the laborious manual work involved in preparing the piping for inspection, such as removal of protective coating, surface polishing and installation of guide track and thereby considerably reduces the duration of inspection. The functioning principle and structural features of the transducer and vehicle are described, together with the results of trial operation of a prototype unit, which proved a 1mm deep notch cut on a test piece of 25mm thick carbon steel plate to be locatable with an accuracy of ±2mm. (author)

  2. Standards for material handling and facilities equipment proofload testing

    Science.gov (United States)

    Bonn, S. P.

    1970-01-01

    Document provides information on verifying the safety of material handling and facilities equipment /MH/FE/, ranging from monorail systems to ladders and non-powered mobile equipment. Seven catagories of MH/FE equipment are defined.

  3. Analysis of noise control measures on outdoor machinery using EQUIP+

    NARCIS (Netherlands)

    Dittrich, M.G.

    2006-01-01

    Noise control of different types of outdoor machinery covered by EU Directive 2000/14/EC such as construction machines, generators and other equipment powered by internal combustion engines requires knowledge of the noise path model and the potential noise control measures. As there is often a

  4. A Study on Performance and Safety Tests of Electrosurgical Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2016-09-01

    Full Text Available Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body. Material and Methods: The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public was evaluated in one of the provinces of Iran according to international and national standards. Results: The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Conclusion: Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  5. A Study on Performance and Safety Tests of Electrosurgical Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2016-09-01

    Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient's safety and management of the risks associated with the use of high and low frequency electrical currents on human body. The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  6. ANSI / FM Approvals 2510 flood abatement equipment test standard

    Directory of Open Access Journals (Sweden)

    Kravetz Frédéric

    2016-01-01

    Full Text Available Natural hazards, including flooding, continue to be the leading cause of commercial and industrial property damage worldwide. Until recently, there has been a limited amount of readily available guidance on choosing flood abatement protection. FM Approvals, a division of FM Global, one of the world’s largest business property insurers, working together with the Association of State Floodplain Managers and the US Army Corps of Engineers have developed a National Flood Barrier Test Program after recognizing the urgent demand for reliable flood abatement products to mitigate potential losses. This lead to the ANSI/ FM2510 flood abatement equipment standard.

  7. Equipment design for reliability testing of protection system

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Tjahjono, H.; Santosa, A. Z.; Tjahjani, S.DT.; Ismu, P.H; Haryanto, D.; Mulyanto, D.; Kusmono, S

    1999-01-01

    The equipment for reliability testing of cable of protection system has been designed as a a furnace with the electric heater have a 4 kW power, and need time 10 minute to reach the designed maximum temperature 3000C. The dimension of furnace is 800 mm diameter and 2000 mm length is isolated use rockwool isolator and coated by aluminium. For the designed maximum temperature the surface temperature is 78 0c. Assemble of specimens is arranged horizontally in the furnace. The failure criteria will be defined based on the behaviour of the load circuit in each line of cable specimens

  8. Control of Nuclear Materials and Special Equipment (Nuclear Safety Regulations)

    International Nuclear Information System (INIS)

    Cizmek, A.; Prah, M.; Medakovic, S.; Ilijas, B.

    2008-01-01

    Based on Nuclear Safety Act (OG 173/03) the State Office for Nuclear Safety (SONS) in 2008 adopted beside Ordinance on performing nuclear activities (OG 74/06) and Ordinance on special conditions for individual activities to be performed by expert organizations which perform activities in the area of nuclear safety (OG 74/06) the new Ordinance on the control of nuclear material and special equipment (OG 15/08). Ordinance on the control of nuclear material and special equipment lays down the list of nuclear materials and special equipment as well as of nuclear activities covered by the system of control of production of special equipment and non-nuclear material, the procedure for notifying the intention to and filing the application for a license to carry out nuclear activities, and the format and contents of the forms for doing so. This Ordinance also lays down the manner in which nuclear material records have to be kept, the procedure for notifying the State administration organization (regulatory body) responsible for nuclear safety by the nuclear material user, and the keeping of registers of nuclear activities, nuclear material and special equipment by the State administration organization (regulatory body) responsible for nuclear safety, as well as the form and content of official nuclear safety inspector identification card and badge.(author)

  9. Improving the Thermal Testing Technology of Technological Equipment of Autonomous Complexes

    Directory of Open Access Journals (Sweden)

    V. V. Chugunkov

    2017-01-01

    Full Text Available The environmental conditions of autonomous objects of different-purpose technical complexes are in close relationship with increased values of operating temperatures. This requires thermal pretesting of the process equipment. The publication [1] considers the thermal test conditions in which the equipment elements under test are placed in a heated water tank covered by the globe insulators where, under automatic temperature control using a block of heaters, they are then kept for a specified period of time at a specified temperature range. Such an approach to the thermal tests of equipment allows us to reduce, but not eliminate completely the mass flows of water from evaporation with reducing power consumption of test equipment.Despite the results achieved, even a little bit of water vapor available when conducting the thermal tests may cause a failure of equipment. Therefore, there is a need in test equipment modernization for complete eliminating the fluxes of mass water and better power consumption in the test process. To this end, it is proposed to place a three-layer bubble wrap on the open surface of water.To justify an efficiency of the proposed option was developed a mathematical model of heat and mass transfer processes that occur during thermal tests, taking into account the geometric and thermo-physical characteristics of test tank, polymer film, and equipment. Using the laws and equations of heat and mass transfer enabled us to determine the required capacities for heating the tank with water and equipment to the required temperature range for a specified time, as well as the mass flows of water when evaporating from the tank surface.The efficiency of the three-layer bubble film as compared with the globe insulators as the elements for covering the test tank the surface has been analysed on the basis of the results obtained.The proposed film coating allowed almost complete elimination of evaporation losses of water mass and almost 8

  10. Outline of sodium-water reaction test in case of large leak with SWAT-3 testing equipments

    International Nuclear Information System (INIS)

    Sato, Minoru

    1978-01-01

    The key component in sodium-cooled fast reactors in steam generators, and the sodium-water reaction owing to the break of heating tubes may cause serious damages in equipments and pipings. The main factor controlling this phenomenon is the rate of leak of water. When the rate of water leak is small, the propagation of heating tube breaking may occur owing to ''wastage phenomenon'', on the other hand, when the rate of water leak is large, the phenomena of explosive pressure and flow occur due to the reaction heat and a large quantity of hydrogen generated by the reaction. In PNC, the testing equipments of SWAT-2 for small water leak and SWAT-1 for large leak were constructed, and the development test has been carried out to establish the method of safety design experimentally. The synthetic test equipment for the safety of steam generators, SWAT-3, was constructed to carry out the large water leak test in the scale close to actual plants. The object of the test, the outline of the test equipment, the phenomena of pressure and flow in the water injection test, the confirmation of the occurrence of secondary breaking of adjacent heating tubes, and the disposal of reaction products are described in this paper. This test is till going on, and the final conclusion will be reported later. (Kako, I.)

  11. Validation Testing for Automated Solubility Measurement Equipment Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

  12. A Study on Performance and Safety Tests of Defibrillator Equipment

    Science.gov (United States)

    Tavakoli Golpaygani, A.; Movahedi, M.M.; Reza, M.

    2017-01-01

    Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices. PMID:29445716

  13. A Study on Performance and Safety Tests of Defibrillator Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2017-12-01

    Full Text Available Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR. Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  14. A Study on Performance and Safety Tests of Defibrillator Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2017-12-01

    Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  15. Photovoltaic System Equipped with Digital Command Control and Acquisition

    OpenAIRE

    Yaden, Med; Melhaoui, Mustapha; Gaamouche, Rajae; Hirech, Kamal; Baghaz, Elhadi; Kassmi, Khalil

    2013-01-01

    In this paper, we present results concerning the design, the realization and the characterization of a photovoltaic system (PV), equipped with a digital controls: Power Point Tracking (MPPT), charge/discharge lead acid batteries, sun tracker and supervision. These different functions are performed with a microcontroller that has capabilities and functions to the reliability of PV systems (signal generation Pulses Width Modulation (PWM), speed etc.). Concerning the MPPT control operation, we i...

  16. Flexible thermal cycle test equipment for concentrator solar cells

    Science.gov (United States)

    Hebert, Peter H [Glendale, CA; Brandt, Randolph J [Palmdale, CA

    2012-06-19

    A system and method for performing thermal stress testing of photovoltaic solar cells is presented. The system and method allows rapid testing of photovoltaic solar cells under controllable thermal conditions. The system and method presents a means of rapidly applying thermal stresses to one or more photovoltaic solar cells in a consistent and repeatable manner.

  17. Survey on quality control measurements for nuclear medicine imaging equipment in Finland in 2006

    International Nuclear Information System (INIS)

    Korpela, Helinae; Niemelae, Jarkko

    2008-01-01

    Routine quality control (QC) is an essential requirement in nuclear medicine (NM) in order to ensure optimal functioning of equipment. To harmonise the routine QC of NM imaging equipment in Finnish hospital s (planar gamma cameras, SPECT, coincidence gamma cameras, PET), the Radiation and Nuclear Safety Authority (STUK) will publish guidelines on QC in collaboration with several hospital physicists. Recommendations will be provided on routine QC measurements and on the frequency of testing. It is also planned to provide recommendations for the acceptance criteria when assessing different performance parameters for NM imaging equipment. In order to determine what performance parameters of NM equipment are currently measured in hospitals, how frequently they are measured and what acceptance criteria are used, a survey was carried out on the QC of NM equipment in Finland during 2006. (author)

  18. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  19. Biomedical equipment for the control of nutrition and for the physical exercise of people with diabetes

    Directory of Open Access Journals (Sweden)

    Aníbal Rubén Mantilla Guerra

    2017-02-01

    Full Text Available In order to contribute to the treatment of diabetes, which is one of the main causes of death in Ecuador and in the world, a research project is being developed to create equipment that allows the effective control and treatment of this disease. The electronic equipment created for nutrition control, allows the diabetic patient to have information about the amount of calories they should ingest in consideration of their activities and their medical treatment. The mechatronic equipment for the physical exercise of people with diabetic foot, allows the application of therapies according to the severity of the affection. Considering that this is a delicate and complex treatment, the equipment helps the patients to alleviate its discomfort, to decrease the time of recovery and in some cases even to avoid amputation. The construction of the biomedical equipment for the control of nutrition is completed. While the equipment for the treatment of diabetic foot is in a stage of development of prototypes and tests. Both equipment has been conceived and developed with rigorous engineering methods and under quality standards, making an important contribution to research, development of science, technology, and innovation.

  20. 30 CFR 250.514 - Well-control fluids, equipment, and operations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Well-control fluids, equipment, and operations... Operations § 250.514 Well-control fluids, equipment, and operations. (a) Well-control fluids, equipment, and... shut in and secured. (b) The following well-control-fluid equipment shall be installed, maintained, and...

  1. 30 CFR 250.1623 - Well-control fluids, equipment, and operations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Well-control fluids, equipment, and operations... Well-control fluids, equipment, and operations. (a) Well-control fluids, equipment, and operations... the well is shut in and secured; (b) The following well-control fluid equipment shall be installed...

  2. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C.; Bresson, J.; Chiffot, T.; Guillot, L. [Centre d`Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L`Energie Atomique, Tille (France)

    1997-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  3. Flight simulation testing equipment for composite material systems

    Science.gov (United States)

    Haskins, J. F.; Wilkins, D. J.; Stein, B. A.

    1976-01-01

    A test program is discussed which aims at establishing the time-temperature-stress characteristics of several classes of high-temperature composite materials in order to determine their suitability for applications in supersonic cruise aircraft. Five advanced composite materials (a boron epoxy, a boron polyimide, a graphite epoxy, a graphite polyimide, and diffusion-bonded boron aluminum) are being evaluated using a flight-test simulator capable of long-term automatic testing based on random loading and realistic flight temperature profiles. The design, construction, and checkout of this simulator are described along with the digital load programmer, load magnitude controllers, the hydraulic pumping system, the heating and cooling systems, the control console, and the data recording system. Typical results for short-term tests performed at constant temperatures and accelerated load rates are presented in terms of a random-load spectrum and a wearout model.

  4. Meteorological testing and analysis of sampling equipment for wet deposition

    International Nuclear Information System (INIS)

    Winkler, P.; Jobst, S.; Harder, C.

    1989-01-01

    11 rain collector types for wet deposition were subjected to a field test. Two of the nine types were identically constructed. The following measured values were analyzed: amount of rainfall, electrical conductivity, pH value, Cl - , NO 3 - , SO 4 = , NH 4 + , Na + , K + , Ca ++ , Mg ++ , Fe, Pb, Cu, Cd. The analysis was restricted to rainfall. In a basic study structural and statistical analyses of precipitations were made in order to find out from which extent of intensity resp. rain volume per rainfall the precipitations are important for wet deposition. Some sensors required intensities of nearly 1 mm/h in order to recognize all rainfalls. In order to reach a better standardization of the measuring technique the funnel geometry should be standardized. The current technique is not suited for correctly registering the deposition which is connected with light and very light rainfall. It was found out in rinsing tests with diluted HNO 3 that considerable amounts of trace metals accumulate at funnel walls and in headers, although the collecting device had been subjected to a thorough acid purification before. For the determination of the wet deposition of the trace metals problems arise if the samples are filtered and the filters are not analyzed. In that case particle-bound metals which are suspended in raindrops will not be registered. After comparing the equipment some of the devices were improved in order to eliminate known sources of contamination. (orig./KW) [de

  5. Financing of power supply systems and pollution control equipment

    International Nuclear Information System (INIS)

    Radtke, G.; Raabe, G.

    1988-01-01

    The authors explain the bankers' point of view of the financial and economic aspects of developments in the energy sector, discussing the financing of natural gas pipelines (Muro, Megal, etc.), of nuclear power plant construction, of projects in the oil supply sector, and of pollution abatement measures and equipment for the power industry and other industries. The different financial situations of small firms or large firms supplying pollution control equipment are discussed referring to the financing schemes to be set up, explaining among other things the profitability assessment taking into account long-term development or delays in return on capital investment from borrowed funds as induced, e.g., by delays in the licensing procedure. Future demand for borrowed capital for pollution control or nuclear power plant development is difficult to assess by the banking circles. (orig./RST) [de

  6. AIChe equipment testing procedure centrifugal compressors : a guide to performance evaluation and site testing

    CERN Document Server

    AIChE

    2013-01-01

    With its engineer-tested procedures and thorough explanations, Centrifugal Compressors is an essential text for anyone engaged in implementing new technology in equipment design, identifying process problems, and optimizing equipment performance.  This condensed book presents a step by step approach to preparing for, planning, executing, and analyzing tests of centrifugal compressors, with an emphasis on methods that can be conducted on-site and with an acknowledgement of the strengths and limitations of these methods. The book opens with an extensive and detailed section offering definitions

  7. Periodic testing of instrumentation and control systems

    International Nuclear Information System (INIS)

    Raimondo, E.

    1989-01-01

    During normal operation, protection systems are on standby and possible failure of system components may therefore go undetected. Their ability to function as intended, should they be initiated after a long period of time, is thus questionable. For this reason, French as well as international rules require that protection systems be subjected to periodic tests. Because of the equipment available when the units in the French 900-MW(electric) series were designed, the instrumentation and control systems were equipped with manual periodic test systems. This was the case with the reactor protection system (RPS) periodic test equipment where the manual procedures relied on the manipulation of a large number of switches and push buttons. This manual test equipment has been successfully replaced on the 28 units in the French 900-MW(electric) series by the automatic tester discussed in this paper

  8. Engineering Work Plan for the Development of Phased Startup Initiative (PSI) Phases 3 and 4 Test Equipment

    International Nuclear Information System (INIS)

    PITNER, A.L.

    2000-01-01

    A number of tools and equipment pieces are required to facilitate planned test operations during Phases 3 and 4 of the Phased Startup Initiative (PSI). These items will be used in assessing residual canister sludge quantities on cleaned fuel assemblies, sorting coarse and fine scrap fuel pieces, assessing the size distribution of scrap pieces, loading scrap into a canister, and measuring the depth of the accumulated scrap in a canister. This work plan supercedes those previously issued for development of several of these test items. These items will be considered prototype equipment until testing has confirmed their suitability for use in K West Basin. The process described in AP-EN-6-032 will be used to qualify the equipment for facility use. These items are considered non-OCRWM for PSI Phase 3 applications. The safety classification of this equipment is General Service, with Quality Level 0 (for PSI Phase 3). Quality Control inspections shall be performed to verify basic dimensions and overall configurations of fabricated components, and any special quality control verifications specified in this work plan (Section 3.1.5). These inspections shall serve to approve the test equipment for use in K West Basin (Acceptance Tag). This equipment is for information gathering only during PSI Phases 3 and 4 activities, and will be discarded at the completion of PSI. For equipment needed to support actual production throughput, development/fabrication/testing activities would be more rigorously controlled

  9. 78 FR 63410 - Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment...

    Science.gov (United States)

    2013-10-24

    ... Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment and Pool Heaters... test procedures for direct heating equipment and pool heaters established under the Energy Policy and... covered products at least once every seven years. For direct heating equipment, the proposed amendments...

  10. Current trends in small vocabulary speech recognition for equipment control

    Science.gov (United States)

    Doukas, Nikolaos; Bardis, Nikolaos G.

    2017-09-01

    Speech recognition systems allow human - machine communication to acquire an intuitive nature that approaches the simplicity of inter - human communication. Small vocabulary speech recognition is a subset of the overall speech recognition problem, where only a small number of words need to be recognized. Speaker independent small vocabulary recognition can find significant applications in field equipment used by military personnel. Such equipment may typically be controlled by a small number of commands that need to be given quickly and accurately, under conditions where delicate manual operations are difficult to achieve. This type of application could hence significantly benefit by the use of robust voice operated control components, as they would facilitate the interaction with their users and render it much more reliable in times of crisis. This paper presents current challenges involved in attaining efficient and robust small vocabulary speech recognition. These challenges concern feature selection, classification techniques, speaker diversity and noise effects. A state machine approach is presented that facilitates the voice guidance of different equipment in a variety of situations.

  11. A train-to-train impact test of crash energy management passenger rail equipment

    Science.gov (United States)

    2006-12-04

    This paper gives an overview of the in-line full-scale impact tests conducted by the Federal : Railroad Administration and discusses a strategy for preventing override between colliding : equipment. Override of the impacting equipment during a passen...

  12. Presentation of accessibility equipment for primary pipings, IHX, pumps and appertaining manipulator tests

    International Nuclear Information System (INIS)

    Hahn, G.; Hoeft, E.

    1980-01-01

    Accessibility and inservice procedure of SNR-300 components are described. Due to the high radiation level in the primary system it was necessary to develop special equipment to permit access to the testing components. The pertinent examination methods for surveying welding seams are acoustic (ultrasonic) and optical procedures (TV cameras, surface crack tests). This can be done by remote-controlled manipulators and special devices, which can transport the inspection system by rails to the testing position. Presently, relatively limited experience exists for such remote-controlled handling in nuclear power plants. Thus model experiments were carried out on a model pipe section at INTERATOM. The performed test shows that the concept planned to perform inservice by using remote-controlled manipulators can be realized successfully. (author)

  13. Research on Architecture of the Prosthesis Shaping Equipment Control System

    Directory of Open Access Journals (Sweden)

    Kai Sun

    2014-06-01

    Full Text Available In order to realize a high speed and high accuracy prosthesis shaping equipment (PSE control system, this paper proposes a new software-hardware architecture of a five-axis high performance NC system. The software part of the proposed architecture follows the rules of the hierarchy and modularity. The inheritance, scalability, and stability are ensured on the whole system and local parts. According to the idea of modular design, the framework uses the client-server mode in the communication and scheduling level. With this way, the reliability of the module management is ensured. The hardware part of the proposed architecture consists of two main parts: the controller and I/O module. The controller is based on FPGA and uses PCI bus and IPC interface. The I/O module is based on ARM + CPLD and uses CAN bus to communicate with the controller. This paper also studies some key problems such as the driving signal producing mechanism. The results of prosthesis shaping equipment prototype show that the system which uses the proposed architecture can reach the positioning accuracy up to 0.02 mm and 3D typical surface cutting accuracy up to 0.02 mm, and this accuracy level already leads similar products in market.

  14. 49 CFR 232.309 - Equipment and devices used to perform single car air brake tests.

    Science.gov (United States)

    2010-10-01

    ... (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR... Testing Requirements § 232.309 Equipment and devices used to perform single car air brake tests. (a) Equipment and devices used to perform single car air brake tests shall be tested for correct operation at...

  15. CONTROL SYSTEM FOR UNMANNED AIRCRAFT EQUIPPED WITH ROBOTICS ARM

    Directory of Open Access Journals (Sweden)

    Alexei A. Margun

    2014-11-01

    Full Text Available The paper deals with the problem of control system synthesis for multi rotational UAV equipped with robotics arm. Control algorithm is proposed based on the method of feedback linearization and synthesis of proportional-differential controller with the real time computation of the inertia tensor and center of mass changes and compensation of the reactive torque generated by the dynamics of the manipulator. Quadrocopter with attached articulated manipulator is selected as a model of the control object. Systems of equations describing the behavior of considered dynamical system are obtained according to the Newton and Euler-Lagrange laws. Expressions are offered, defining the inertia tensor and the position of the system center of mass depending on the current position of the manipulator, and the torque acting on the quadrocopter from the manipulator. Feedback linearization with arm influence compensation on quadrocopter is applied for the resulting nonlinear coupled system. As a result, robot dynamics equations have been converted to a linear stationary system. Converted system control is achieved by a proportional-differential controller. Examined system simulation is done with control method described in the paper and the classical method based on a proportional-differential controller. Simulation results confirm the effectiveness of the proposed approach and demonstrate that the proposed approach provides higher accuracy of the tracking error, than control method by means of proportional-differential regulator.

  16. TANK 18 AND 19-F TIER 1A EQUIPMENT FILL MOCK UP TEST SUMMARY

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Langton, C.

    2011-11-04

    The United States Department of Energy (US DOE) has determined that Tanks 18-F and 19-F have met the F-Tank Farm (FTF) General Closure Plan Requirements and are ready to be permanently closed. The high-level waste (HLW) tanks have been isolated from FTF facilities. To complete operational closure they will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) discouraging future intrusion, and (4) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. Bulk waste removal and heel removal equipment remain in Tanks 18-F and 19-F. This equipment includes the Advance Design Mixer Pump (ADMP), transfer pumps, transfer jets, standard slurry mixer pumps, equipment-support masts, sampling masts, dip tube assemblies and robotic crawlers. The present Tank 18 and 19-F closure strategy is to grout the equipment in place and eliminate vertical pathways by filling voids in the equipment to vertical fast pathways and water infiltration. The mock-up tests described in this report were intended to address placement issues identified for grouting the equipment that will be left in Tank 18-F and Tank 19-F. The Tank 18-F and 19-F closure strategy document states that one of the Performance Assessment (PA) requirements for a closed tank is that equipment remaining in the tank be filled to the extent practical and that vertical flow paths 1 inch and larger be grouted. The specific objectives of the Tier 1A equipment grout mock-up testing include: (1) Identifying the most limiting equipment configurations with respect to internal void space filling; (2) Specifying and constructing initial test geometries and forms that represent scaled boundary conditions; (3) Identifying a target grout rheology for evaluation in the scaled mock-up configurations; (4) Scaling-up production of a grout mix with the target rheology

  17. Mechanical and dosimetric quality control for computer controlled radiotherapy treatment equipment.

    Science.gov (United States)

    Thompson, A V; Lam, K L; Balter, J M; McShan, D L; Martel, M K; Weaver, T A; Fraass, B A; Ten Haken, R K

    1995-05-01

    Modern computer controlled radiotherapy treatment equipment offers the possibility of delivering complex, multiple field treatments with minimal operator intervention, thus making multiple field conformal therapy practical. Conventional quality control programs are inadequate for this new technology, so new quality control procedures are needed. A reasonably fast, sensitive, and complete daily quality control program has been developed in our clinic that includes nearly automated mechanical as well as dosimetric tests. Automated delivery of these quality control fields is performed by the control system of the MM50 racetrack microtron, directed by the CCRS sequence processor [D. L. McShan and B. A. Fraass, Proceedings of the XIth International Conference on the use of computers in Radiation Therapy, 20-24 March 1994, Manchester, U.K. (North Western Medical Physics Department, Manchester, U.K., 1994), pp. 210-211], which controls the treatment process. The mechanical tests involve multiple irradiations of a single film to check the accuracy and reproducibility of the computer controlled setup of gantry and collimator angles, table orientation, collimator jaws, and multileaf collimator shape. The dosimetric tests, which involve multiple irradiations of an array of ionization chambers in a commercial dose detector (Keithly model 90100 Tracker System) rigidly attached to the head of the treatment gantry, check the output and symmetry of the treatment unit as a function of gantry and collimator angle and other parameters. For each of the dosimetric tests, readings from the five ionization chambers are automatically read out, stored, and analyzed by the computer, along with the geometric parameters of the treatment unit for that beam.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Power supply provisions for instrumentation and control equipment

    International Nuclear Information System (INIS)

    Goethe, J.R.

    1982-01-01

    Instrumentation and Control systems - one may consider these installations as the nerve system and the brain of a nuclear power plant. According to their supreme importance, power supply for these systems has to be of the highest standard to be found in the plant. In short, I and C power supply systems in nuclear power plants are designed to assure a safe and noninterruptive power supply to I and C equipment under all design basis conditions. The concept as presented here is applied in the KWU 1300 MW PWR plants that are currently being planned or under construction. (orig./RW)

  19. Performance Test of the Salt transfer and Pellet fabrication of UCl3 Making Equipment for Electrorefining

    International Nuclear Information System (INIS)

    Woo, M. S.; Jin, H. J.; Park, G. I.; Park, S. B.

    2014-01-01

    The process to produce a uranium chloride salt includes two steps: a reaction process of gaseous chlorine with liquid cadmium to form the CdCl 2 occurring in a Cd layer, followed by a process to produce UCl 3 by the reaction of U in the LiCl-KCl eutectic salt and CdCl 2 . Chemical reaction is next chlorination reaction; - Cd chlorination : Cd + Cl2 → CdCl 2 - U chlorination : 3CdCl2 + 2U → 3Cd + 2UCl 3 The apparatus for producing UCl 3 consists of a chlorine gas generator, a uranium chlorinator, a Cd distiller, the pelletizer, a off-gas wet scrubber and a dry scrubber. Salt transfer system set among reactors to transfer salt at 500 .deg. C. The temperature of the reactants is maintained at about 600 .deg. C. After the reaction is completed in the uranium chlorinator, The Salt product is transferred to the Cd distiller to decrease residual Cd concentration in the salts, and then salt is transferred to the mould of pelletizer by a transfer system to fabricate pellet type salt. Performance test of the salt transfer and pellet fabrication of its equipment was tested in this work. Performance test of the salt transfer and pellet fabrication of UCl3 making equipment for Electrorefining carried out in this work. The result of equipment test is that melted salt at 600 .deg. C was easy transferred by salt transfer equipment heated at 500 .deg. C. In this time, salt transfer was carried out by argon gas pressurization at 3bar. When velocity of salt transfer was controlled under reduce pressure, velocity of salt transfer was difficult to control. And when salt pellet was fabricated by the mold of pelletizer heated at 90 .deg. C better than mold of pelletizer heated at 200 .deg. C because salt melted prevent leakage from mold of pelletizer

  20. Using cyber vulnerability testing techniques to expose undocumented security vulnerabilities in DCS and SCADA equipment

    International Nuclear Information System (INIS)

    Pollet, J.

    2006-01-01

    This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-critical networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)

  1. Using cyber vulnerability testing techniques to expose undocumented security vulnerabilities in DCS and SCADA equipment

    Energy Technology Data Exchange (ETDEWEB)

    Pollet, J. [PlantData Technologies, Inc., 1201 Louisiana Street, Houston, TX 77002 (United States)

    2006-07-01

    This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-critical networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)

  2. Retrofit of waste-to-energy facilities equipped with electrostatic precipitators. Volume III: Test protocol

    Energy Technology Data Exchange (ETDEWEB)

    Rigo, H.G. [Rigo & Rigo Associates, Inc., Berea, OH (US); Chandler, A.J. [A.J. Chandler & Associates, Inc., Toronto, Ontario (Canada)

    1996-04-01

    The American Society of Mechanical Engineers' [ASME] Center for Research and Technology Development [CRTD] has been awarded a subcontract by the National Renewable Energy Laboratory [NREL] to demonstrate the technical performance and viability of flue gas temperature control in combination with dry acid gas reagent and activated carbon injection at an existing electrostatic precipitator [ESP] equipped municipal waste combustor [MWC]. The objective of this proof-of-concept demonstration test is to economically and reliably meet 40 CFR 60 Subpart Cb Emissions Guidelines for MWC's at existing ESP equipped facilities. The effort is being directed by a Subcommittee of tile ASME Research Committee on Industrial and Municipal Wastes [RCIMW] chaired by Dave Hoecke. Mr. Greg Barthold of ASME/CRTD is the Project Manager. ASME/CRTD contracted with Rigo & Rigo Associates, Inc. in cooperation with A.J. Chandler & Associates, Ltd. to be the Principal Investigator for the project and manage the day-t o-day aspects of the program, conduct the testing reduce and interpret the data and prepare the report. Testing will be conducted at the 2 by 210 TPD, ESP equipped MWC at the Davis County Resource Recovery Facility in Layton, Utah. The test plan calls for duplicate metals (Cd, Pb and Hg), dioxin and acid gas runs.

  3. Field test of distribution automation equipment at Kansas Utilities

    International Nuclear Information System (INIS)

    Pahwa, A.; Shultis, J.K.; Dowling, W.N.

    1991-01-01

    Distribution automation can be beneficial to the utilities by reducing operating cost and increasing efficiency. Since needs of most utilities are different, obtaining first hand experience with distribution automation equipment is important. In this paper experiences of Kansas City Power and Light Co., and Midwest Energy, Inc. (members of Kansas Electric Utilities Research Program) related to operation of pilot distribution automation systems are described. Data gathered on failure of equipment is also included. As a part of this project, a microcomputer program was developed for cost/benefit analysis of eight distribution automation functions. In this paper salient features of this program are discussed and results of an example are presented

  4. Nuclear electronics equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    Roquefort, Henri

    1980-09-01

    The purpose of this document is to fix what terminology should be used, to define the main specifications of supplies and to specify the test methods recommended to check these specifications. This document applies to low and high voltage supply sub-units fed by AC or DC mains supply and delivering direct current under stabilised DC voltage. These sub-units are used in nuclear electronics equipment and especially for reactor monitoring. Following the definition of some terms, current notations and a bibliography, the characteristics section and the corresponding test methods section are developed. Each section deals in particular with: input and output characteristics, linearity and display errors, fluctuations, influence and operation errors, variations, drift (stability), variations with the main influence quantities: mains, temperature, load, transient variations, insulation, shielding, microbreakdowns, emergency supply, electromagnetic perturbation sensitivity, reliability, maintainability and characteristics specific to certain supplies used for the polarisation of radiation detectors [fr

  5. Zirconium Recycle Test Equipment for Hot Cell Operations

    International Nuclear Information System (INIS)

    Collins, Emory D.; DelCul, Guillermo Daniel; Spencer, Barry B.; Bradley, Eric Craig; Brunson, Ronald Ray

    2015-01-01

    The equipment components and assembly support work were modified for optimized, remote hot cell operations to complete this milestone. The modifications include installation of a charging door, Swagelok connector for the off-gas line between the reactor and condenser, and slide valve installation to permit attachment/replacement of the product salt collector bottle.

  6. AUTOMATED REMOTE MANAGEMENT AND CONTROL SYSTEM OF THE LABORATORY EQUIPMENT

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2017-01-01

    Full Text Available The paper deals with the hardware and software implementation of automated remote management system of laboratory equipment for studying fundamentals of electronics and circuit technology. This system gives the possibility to create the virtual model of a real stand. The original software has enabled to compare information from the memory of microcontroller keeping in laboratory stands with etalon model, and reveal discrepancies of set connections and template data. Graphical interface allows for operation control of students and correction of studying process. Automation of configuring and the following checking procedures has accelerated the work and decreased error frequency, made it possible to improve the quality of learning, increase efficiency of laboratory researches and control accuracy, intensify the check procedure and use self-checking in case of independent execution of tasks.

  7. Photovoltaic System Equipped with Digital Command Control and Acquisition

    Directory of Open Access Journals (Sweden)

    Khalil Kassmi

    2013-07-01

    Full Text Available In this paper, we present results concerning the design, the realization and the characterization of a photovoltaic system (PV, equipped with a digital controls: Power Point Tracking (MPPT, charge/discharge lead acid batteries, sun tracker and supervision. These different functions are performed with a microcontroller that has capabilities and functions to the reliability of PV systems (signal generation Pulses Width Modulation (PWM, speed etc.. Concerning the MPPT control operation, we improved the accuracy and reliability of research by improving the search algorithm “Hill Climbing” taking into account the optimal operation of PV panels depending on weather conditions (temperature and light.The experiment of each block shows that the MPPT control converges instantly the operating point of the PV panels around the maximum power point, independently of sudden changes of the illumination or the load. The control blocks charge/discharge battery and sun tracking show good control of charge/discharge lead acid batteries and the need of sun tracker to increase the power supplied by the PV panel. By using the improved MPPT control, loss of power supplied by the PV panels are very low (below 5%.

  8. Control rod testing apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.R.; Ashman, C.M.

    1987-06-02

    A control rod testing apparatus is described comprising: a first guide means having a vertical cylindrical opening for grossly guiding a control rod; a second guide means having a vertical cylindrical opening for grossly guiding a control rod. The first and second guide means are supported at axially spaced locations with the openings coaxial; and a substantially cylindrical subassembly having a vertical cylindrical opening therethrough. The subassembly is trapped coaxial with and between the first and second guide means, and the subassembly radially floats with respect to the first and second guide means.

  9. Control rod testing apparatus

    International Nuclear Information System (INIS)

    Gaunt, R.R.; Ashman, C.M.

    1987-01-01

    A control rod testing apparatus is described comprising: a first guide means having a vertical cylindrical opening for grossly guiding a control rod; a second guide means having a vertical cylindrical opening for grossly guiding a control rod. The first and second guide means are supported at axially spaced locations with the openings coaxial; and a substantially cylindrical subassembly having a vertical cylindrical opening therethrough. The subassembly is trapped coaxial with and between the first and second guide means, and the subassembly radially floats with respect to the first and second guide means

  10. Data acquisition, remote control and equipment monitoring for ISOLDE RILIS

    CERN Document Server

    Rossel, R E; Richter, D; Wendt, K D A; Rothe, S; Marsh, B A

    2013-01-01

    With a steadily increasing on-line operation time up to a record 3000 h in the year 2012, the Resonance Ionization Laser Ion Source (RILIS) is one of the key components of the ISOLDE on-line isotope user facility at CERN. Ion beam production using the RILIS is essential for many experiments due to the unmatched combination of ionization efficiency and selectivity. To meet the reliability requirements the RILIS is currently operated in shift duty for continuous maintenance of crucial laser parameters such as wavelength, power, beam position and timing, as well as ensuring swift intervention in case of an equipment malfunction. A recent overhaul of the RILIS included the installation of new pump lasers, commercial dye lasers and a complementary, fully solid-state titanium:sapphire laser system. The framework of the upgrade also required the setup of a network-extended, LabVIEW-based system for data acquisition, remote control and equipment monitoring, to support RILIS operators as well as ISOLDE users. The syst...

  11. Maintenance and test strategies to optimize NPP equipment performance

    International Nuclear Information System (INIS)

    Mayer, S.; Tomic, B.

    2000-01-01

    This paper proposes an approach to maintenance optimization of nuclear power plant components, which can help to increase both safety and availability. In order to evaluate the benefits of preventive maintenance on a quantitative basis, a software code has been developed for component performance and reliability simulation of safety related nuclear power plant equipment. A three state Markov model will be introduced, considering a degraded state in addition to an operational state and a failed state. (author)

  12. 30 CFR 250.614 - Well-control fluids, equipment, and operations.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Well-control fluids, equipment, and operations... Operations § 250.614 Well-control fluids, equipment, and operations. The following requirements apply during all well-workover operations with the tree removed: (a) Well-control fluids, equipment, and operations...

  13. 7 CFR 1717.613 - RUS approval of data processing and system control equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false RUS approval of data processing and system control... system control equipment. If a borrower's mortgage or loan contract requires the borrower to obtain approval from RUS before purchasing data processing equipment or system control equipment, such approval is...

  14. Regulation EM-GT-8. Guidance for quality control of mammography equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Objective: To provide practical guidance of technical procedures for carrying out quality control in mammography equipment. Scope: This guide applies to mammography equipment. A number of methods which require the appointed instrumentation described, some of which can be implemented in radiology services own country given the low complexity of themselves and others that require specific equipment and can be performed by specialized groups external to these units. The guide does not constitute a mandatory, however, the parameters evaluated according to the tests described therein and their tolerances form the basis of regulations that establish the CCEEM about these teams. Overview: The success of mammographic studies depends on obtaining high-quality images combined with a low rate of patient dose. To ensure this objective the establishment of quality assurance programs on all aspects involving these services is necessary. This guide provides a number of quality control procedures aimed at x-ray equipment, which must be performed at least on an annual basis or when some maintenance occurs at x-ray equipment.

  15. Lighting Control System for Premises with Display Screen Equipment

    Science.gov (United States)

    Kudryashov, A. V.

    2017-11-01

    The use of Display Screen Equipment (DSE) at enterprises allows one to increase the productivity and safety of production, minimize the number of personnel and leads to the simplification of the work of specialists, but on the other side, changes usual working conditions. If the personnel works with displays, visual fatigue develops more quickly which contributes to the emergence of nervous tension, stress and possible erroneous actions. Low interest of the lighting control system developers towards the rooms with displays is dictated by special requirements for coverage by sanitary and hygienic standards (limiting excess workplace illumination). We decided to create a combined lighting system which works considering daylight illumination and artificial light sources. The brightness adjustment of the LED lamps is carried out according to the DALI protocol, adjustment of the natural illumination by means of smart glasses. The technical requirements for a lighting control system, the structural-functional scheme and the algorithm for controlling the operation of the system have been developed. The elements of control units, sensors and actuators have been selected.

  16. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  17. 14 CFR Appendix J to Part 23 - HIRF Environments and Equipment HIRF Test Levels

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false HIRF Environments and Equipment HIRF Test Levels J Appendix J to Part 23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF.... 23, App. J Appendix J to Part 23—HIRF Environments and Equipment HIRF Test Levels This appendix...

  18. Facility-wide synchronization of standard FAIR equipment controllers

    International Nuclear Information System (INIS)

    Rauch, S.; Terpstra, W.; Panschow, W.; Thieme, M.; Prados, C.; Zweig, M.; Kreider, M.; Beck, D.; Bär, R.

    2012-01-01

    The standard equipment controller under development for the new FAIR accelerator facility is the Scalable Control Unit (SCU). It is designed to synchronize and control the actions of up to 12 purpose-built slave cards, connected in a proprietary crate by a parallel backplane. Inter-crate coordination and facility-wide synchronization are a core FAIR requirement and thus precise timing of SCU slave actions is of vital importance. The SCU consists primarily of two components, an x86 COM Express daughter board and a carrier board with an Altera Arria II GX FPGA, interconnected by PCI Express. The x86 receives configuration and set values with which it programs the real-time event-condition-action (ECA) unit in the FPGA. The ECA unit receives event messages via the timing network, which also synchronizes the clocks of all SCUs in the facility using White Rabbit. Matching events trigger actions on the SCU slave cards such as: ramping magnets, triggering kickers, etc. Timing requirements differ depending on the action taken. For softer real-time actions, an interrupt can be generated for complex processing on the x86. Alternatively, the FPGA can directly fire a pulse out a LEMO output or an immediate SCU bus operation. The delay and synchronization achievable in each case differs and this paper examines the timing performance of each to determine which approach is appropriate for the required actions. (author)

  19. Framed bit error rate testing for 100G ethernet equipment

    DEFF Research Database (Denmark)

    Rasmussen, Anders; Ruepp, Sarah Renée; Berger, Michael Stübert

    2010-01-01

    of performing bit error rate testing at 100Gbps. In particular, we show how Bit Error Rate Testing (BERT) can be performed over an aggregated 100G Attachment Unit Interface (CAUI) by encapsulating the test data in Ethernet frames at line speed. Our results show that framed bit error rate testing can...... functionality besides the bit error rate tester....

  20. Quality Control Program for radiodiagnostic equipment on the Department of Antioquia, Colombia

    International Nuclear Information System (INIS)

    Beltran, Camilo; Viloria, Carolina; Puerta, Anselmo; Morales, Javier; Martinez, Piedad

    2008-01-01

    The Health Sectional Direction of Antioquia DSSA and the National University of Colombia campus Medellin have been formalizing inter-administrative agreements to realize Quality Control Studies on the institutions of medical radiodiagnostics of the department. In the first phase of the project on 2006, quality control studies were completed on 40 conventional and 31 mammography equipment, in the second phase by the end of 2006, 21 fluoroscopy, interventionism and C arms equipment were also studied; the third phase, finished by the end of 2007, counted with 50 conventional equipment. The tests proposed on the ARCAL XLIX IAEA protocol, tests on the installations, on the generator, on the image systems and the patient dosimetry were performed. From the evaluations on the installations, reports with relevant recommendations to be considerate and implemented to perform a better use of own resources on each institution were elaborated. On this paper, current results, impact on the participating institutions and the benefits from the applications that these kinds of practices bring to the institutions are presented. Finally, the necessity to advance towards clear politics in order to impulse the implementation of quality assurance programs in radiodiagnostic institutions, looking to improve the quality of diagnostic images with patient benefits, higher trust on technical conditions of equipment for a better and adequate diagnose, as well as to advance on processes seeking the optimization of radiological protection on the patient and the personnel occupationally exposed, is presented. (author)

  1. Control of equipment isolation system using wavelet-based hybrid sliding mode control

    Science.gov (United States)

    Huang, Shieh-Kung; Loh, Chin-Hsiung

    2017-04-01

    Critical non-structural equipment, including life-saving equipment in hospitals, circuit breakers, computers, high technology instrumentations, etc., is vulnerable to strong earthquakes, and on top of that, the failure of the vibration-sensitive equipment will cause severe economic loss. In order to protect vibration-sensitive equipment or machinery against strong earthquakes, various innovative control algorithms are developed to compensate the internal forces that to be applied. These new or improved control strategies, such as the control algorithms based on optimal control theory and sliding mode control (SMC), are also developed for structures engineering as a key element in smart structure technology. The optimal control theory, one of the most common methodologies in feedback control, finds control forces through achieving a certain optimal criterion by minimizing a cost function. For example, the linear-quadratic regulator (LQR) was the most popular control algorithm over the past three decades, and a number of modifications have been proposed to increase the efficiency of classical LQR algorithm. However, except to the advantage of simplicity and ease of implementation, LQR are susceptible to parameter uncertainty and modeling error due to complex nature of civil structures. Different from LQR control, a robust and easy to be implemented control algorithm, SMC has also been studied. SMC is a nonlinear control methodology that forces the structural system to slide along surfaces or boundaries; hence this control algorithm is naturally robust with respect to parametric uncertainties of a structure. Early attempts at protecting vibration-sensitive equipment were based on the use of existing control algorithms as described above. However, in recent years, researchers have tried to renew the existing control algorithms or developing a new control algorithm to adapt the complex nature of civil structures which include the control of both structures and non

  2. Quality control procedures for equipment: The EORTC radiotherapy group experience

    International Nuclear Information System (INIS)

    Garavaglia, G.; Mijnheer, B.

    1997-01-01

    The QA program of the Radiotherapy Co-operative Group of the EORTC (European Organisation for Research and Treatment of Cancer) has included quality control procedures for equipment from its starting date in 1982. During on-site visits carded out by a team of radiotherapists and physicists the following equipment checks and measurements were performed: mechanical and beam alignment checks of simulator and therapy units; measurements of the dose homogeneity for X-ray and electron beams; intercomparison of ionization chambers; measurements of the depth dose distribution at several depths; absorbed dose determination in specific points in water for several combinations of field sizes and accessories, for photon and electron beams. In addition calculations of treatment time and monitor units were carried out for reference cases and the relevant beam data from all machines in use were collected. In order to provide a follow-up of the on-site visits, a mailed TLD program was then established in 1986. The program has been very successful, the centers are eager to participate since it constitutes an independent check of the measurements performed by the local physicists. It also allows to detect dosimetric problems in centers not yet included in the site visit program. To date, all participating centers have been monitored by mailed TLD, several more than once. This has led to the decision of stopping the site visits unless large deviations cannot be resolved by a second TLD mailing. The Radiation Physics Department of the Goeteborg, University Hospital has been the main partner in this QA effort. Since 1993 the mailed TLD program continues in co-operation with the Institut Gustave Roussy in Villejuif. Besides water phantom measurements on the beam axis, the IGR, in collaboration with the Radiation Physics Center in Houston, is planning a procedure to check off-axis doses by means of a TLD-loaded multi-purpose phantom. (author)

  3. Analysis of quality control protocol implementation of equipment in radiotherapy services

    International Nuclear Information System (INIS)

    Calcina, Carmen S. Guzman; Lima, Luciana P. de; Rubo, Rodrigo A.; Ferraz, Eduardo; Almeida, Adelaide de

    2000-01-01

    Considering the importance of the Quality Assurance in the radiotherapy services, there was an interest to make tests' evaluation for a Quality Control for the cobalt equipment, linear accelerator and simulator as a classification and comparison. The work proposed is a suggestion that can serve as tool for medical physicists that are starting to work in the radiotherapy area and for the most experts. The discussions were made by the gathering of local tests and official protocols, resulting in a minimum protocol as a suggestion for a routine work, emphasizing the periodicity and level of tolerance of each one of the tests. (author)

  4. A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry

    International Nuclear Information System (INIS)

    Dong, Kyung Rae; Kim, Ho Sung; Jung, Woon Kwan

    2008-01-01

    =0.96), P2 - (spine: 0.002±0.018 g/cm 2 , %CV=0.55, Femur: 0.001±0.013 g/cm 2 , %CV=0.48) in Group 3. The average error±2SD, %CV, and r value was spine : 0.006±0.024 g/cm 2 , %CV=0.86, r=0.995, Femur: 0±0.014 g/cm 2 , %CV=0.54, r=0.998 in Group 4. Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ±2% defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  5. A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health College, Gwangju (Korea, Republic of); Kim, Ho Sung [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of); Jung, Woon Kwan [Dept. of Nuclear Energy Technology, Chosun University, Gwangju (Korea, Republic of)

    2008-03-15

    .94, Femur: 0.001{+-}0.019 g/cm{sup 2}, %CV=0.96), P2 - (spine: 0.002{+-}0.018 g/cm{sup 2}, %CV=0.55, Femur: 0.001{+-}0.013 g/cm{sup 2}, %CV=0.48) in Group 3. The average error{+-}2SD, %CV, and r value was spine : 0.006{+-}0.024 g/cm{sup 2}, %CV=0.86, r=0.995, Femur: 0{+-}0.014 g/cm{sup 2}, %CV=0.54, r=0.998 in Group 4. Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of {+-}2% defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  6. The Equipment of Using AZOLLA for O2-Supplimentation and its Test

    Science.gov (United States)

    Chen, Min; Liu, Xia-Shi; Bian, Zu-Liang; Liu, Chung-Chu

    The equipment of using Azolla for O2-supplementation and food-production in future space station was developed and tested. Dog was used as the O2-consumming animal. The design of this device considered both the requirement of Azolla growth, such as illumination, temperature, humidity, nutrition and biomass harvesting, and also the food supplement, excretion draining and temperature controlling for the dog under the condition of an airtight chamber for a relatively long duration. This device was preliminarily tested for O2-release by Azolla, and data about O2-supplementation by Azolla were obtained. Results showed that Azolla is one potential plant as O2-supplementation in future space station. Key words: Azolla, oxygen supply systems, test, chambers, closed ecological systems, oxygen supplement

  7. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING...

  8. Control of sealed sources and equipments used in gammagraphy

    International Nuclear Information System (INIS)

    Sahyun, A.; Sordi, G.-M.A.A.; Biazzini Filho, F.L.

    1988-01-01

    The Radiation Protection Department of the IPEN-CNEN/SP, in 1987, formed a section incharged to control all radioactive material: a) received by the IPEN-CNEN/SP; b) produced by the IPEN-CNEN/SP; c) delivered from the IPEN-CNEN/SP. The aim of this section is to maintain a permanent control of all radioactive sources movement got at the IPEN-CNEN/SP. This control is performed with a microcomputer, trademark MICRODIGITAL, model TK3000 //e, 256 KBytes of memory, utilizing the TOTALWORKS program. This program permits to have the origin, characteristics and address of the radioactive sources, its sites in the IPEN, its uses, etc. Already we have put in the microcomputer, the control of the sealed sources produced used in nondestructive test, the inspection control of the gamagraphy irradiator and the control of the depleted sources. The next step is to introduce in the computer the inspection of the remote control of the irradiator. The aim of this paper is to describe the control program that was already put on. This radioactive material control was started with the sealed sources used in gamagraphy because we believe that is the field with the most likelihood of accident in the population, and therefore it's that need the most hard control about the site and the performance of the irradiation facility. (author) [pt

  9. Acceptance test procedure for K basins dose reduction project clean and coat equipment

    International Nuclear Information System (INIS)

    Creed, R.F.

    1996-01-01

    This document is the Acceptance Test Procedure (ATP) for the clean and coat equipment designed by Oceaneering Hanford, Inc. under purchase order MDK-XVC-406988 for use in the 105 K East Basin. The ATP provides the guidelines and criteria to test the equipment's ability to clean and coat the concrete perimeter, divider walls, and dummy elevator pit above the existing water level. This equipment was designed and built in support of the Spent Nuclear Fuel, Dose Reduction Project. The ATP will be performed at the 305 test facility in the 300 Area at Hanford. The test results will be documented in WHC-SD-SNF-ATR-020

  10. Seismic fragility capacity of equipment--horizontal shaft pump test

    International Nuclear Information System (INIS)

    Iijima, T.; Abe, H.; Suzuki, K.

    2005-01-01

    The current seismic fragility capacity of horizontal shaft pump is 1.6 x 9.8 m/s 2 (1.6 g), which was decided from previous vibration tests and we believe that it must have sufficient margin. The purpose of fragility capacity test is to obtain realistic seismic fragility capacity of horizontal shaft pump by vibration tests. Reactor Building Closed Cooling Water (RCW) Pump was tested as a typical horizontal shaft pump, and then bearings and liner rings were tested as important parts to evaluate critical acceleration and dispersion. Regarding RCW pump test, no damage was found, though maximum input acceleration level was 6 x 9.8 m/s 2 (6 g). Some kinds of bearings and liner rings were tested on the element test. Input load was based on seismic motion which was same with the RCW pump test, and maximum load was equivalent to over 20 times of design seismic acceleration. There was not significant damage that caused emergency stop of pump but degradation of surface roughness was found on some kinds of bearings. It would cause reduction of pump life, but such damage on bearings occurred under large seismic load condition that was equivalent to over 10 to 20 g force. Test results show that realistic fragility capacity of horizontal shaft pump would be at least four times as higher as current value which has been used for our seismic PSA. (authors)

  11. Irradiation position-control equipment for the HIMAC

    Energy Technology Data Exchange (ETDEWEB)

    Higashi, Seiichi; Kuma, Shoichiro [Mitsubishi Electric Corp., Tokyo (Japan); Nomura, Kazuaki; Endo, Masahiro; Minohara, Shin-ichi

    1995-02-01

    Use of heavy-ion beams to mount a pinpoint attack on unhealthy tissue requires that the target tissue be placed in the precise location specified by the therapy planning equipment. The article reports on the detailed specifications, positioning mechanism, position verification method and the interface with the therapy planning equipment. (author).

  12. Systematic approach in protection and ergonomics testing personal protective equipment

    NARCIS (Netherlands)

    Hartog. E.A. den

    2009-01-01

    In the area of personal protection against chemical and biological (CB) agents there is a strong focus on testing the materials against the relevant threats. The testing programs in this area are elaborate and are aimed to guarantee that the material protects according to specifications. This

  13. 30 CFR 7.86 - Test equipment and specifications.

    Science.gov (United States)

    2010-07-01

    ...-3.2 (3) The test fuel temperature at the inlet to the diesel engine's fuel injection pump shall be... dilution air; (ii) Be at least 3 inches (75 mm) in diameter; and (iii) Be configured to direct the engine..., EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Engines Intended for...

  14. ECOLOGICAL CONTROL EQUIPMENT AND TECHNOLOGY OF UNDERWATER VEGETATION DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    V. TITINSCHNEIDER

    2008-10-01

    Full Text Available The excess of aquatic submerse vegetation development carries to the reduction of the real rearing area for the piscicultural material from the production farms and allow nestling of the ichthyophages bird species that decrease the fish production. Aquatic submerse vegetation stumble the utilization of aquatic zones for recreation and also wright function of basins utilized for the electric energy production, of micro electricity works through obstruction of the dams grid. The control of the aquatic submerse vegetation development, for Myriophyllum verticillatum, Ceratophyllum submersum, Urticularia vulgaris, Potamogeton natans, Nimphoides peltata species it is accomplish through the removing of some parts of these, preferably with all the stump system. Usually, these its accomplish with the floating equipments fit up with the thermic engines and the propulsion and governating elements who have harm over the fish and some others aquatic organisms through the noise, the displacing a large quality of water caused of propulsion systems and through the noxes elimination (flue, carburant trails, etc.. These technologies reside from the evacuation of the aquatic submerse vegetation and the stump systems of these with the help of an adjustable rake, hang up from the coast by a rope, wrapped to a drummer, who is trained by a motto-propeller group with a small installed power.

  15. Shuttle orbiter Ku-band radar/communications system design evaluation. Deliverable test equipment evaluation

    Science.gov (United States)

    Maronde, R. G.

    1980-07-01

    The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.

  16. 46 CFR 197.206 - Substitutes for required equipment, materials, apparatus, arrangements, procedures, or tests.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Substitutes for required equipment, materials, apparatus, arrangements, procedures, or tests. 197.206 Section 197.206 Shipping COAST GUARD, DEPARTMENT OF HOMELAND... Operations General § 197.206 Substitutes for required equipment, materials, apparatus, arrangements...

  17. Control of nuclear material specified equipment and specified material

    International Nuclear Information System (INIS)

    1982-04-01

    The goal and application field of NE 2.02 regulatory guide of CNEN (Comissao Nacional de Energia Nuclear), are described. This regulatory guide is about nuclear material management, specified equipment and specified material. (E.G.) [pt

  18. New control system: the commands of the settings equipments

    International Nuclear Information System (INIS)

    David, L.; Maugeais, C.

    1992-01-01

    The equipments allowing the setting of the GANIL beam (motors, probes, supplies...) may be operated by three distinct ways: by dial (pseudo potentiometer), by menu or by slider. These processes are described. (A.B.)

  19. Novel Field Test Equipment for Lithium-Ion Batteries in Hybrid Electrical Vehicle Applications

    Directory of Open Access Journals (Sweden)

    Goran Lindbergh

    2011-04-01

    Full Text Available Lifetime testing of batteries for hybrid-electrical vehicles (HEV is usually performed in the lab, either at the cell, module or battery pack level. Complementary field tests of battery packs in vehicles are also often performed. There are, however, difficulties related to field testing of battery-packs. Some examples are cost issues and the complexity of continuously collecting battery performance data, such as capacity fade and impedance increase. In this paper, a novel field test equipment designed primarily for lithium-ion battery cell testing is presented. This equipment is intended to be used on conventional vehicles, not hybrid vehicles, as a cheaper and faster field testing method for batteries, compared to full scale HEV testing. The equipment emulates an HEV environment for the tested battery cell by using real time vehicle sensor information and the existing starter battery as load and source. In addition to the emulated battery cycling, periodical capacity and pulse testing capability are implemented as well. This paper begins with presenting some background information about hybrid electrical vehicles and describing the limitations with today’s HEV battery testing. Furthermore, the functionality of the test equipment is described in detail and, finally, results from verification of the equipment are presented and discussed.

  20. On-Line Radiation Test Facility for Industrial Equipment needed for the Large Hadron Collider at CERN

    CERN Document Server

    Rausch, R

    1999-01-01

    The future Large Hadron Collider to be built at CERN will use superconducting magnets cooled down to 1.2 K. To preserve the superconductivity, the energy deposition dose levels in equipment located outside the cryostat, in the LHC tunnel, are calculated to be of the order of 1 to 10 Gy per year. At such dose levels, no major radiation-damage problems are to be expected, and the possibility of installing Commercial Of The Shelf (COTS) electronic equipment in the LHC tunnel along the accelerator is considered. To this purpose, industrial electronic equipment and circuits have to be qualified and tested against radiation to insure their long term stability and reliability. An on-line radiation test facility has been setup at the CERN Super Proton Synchrotron (SPS) and a program of on-line tests for electronic equipment is ongoing. Equipment tested includes Industrial Programmable Logic Controllers (PLCs) from several manufacturers, standard VME modules, Fieldbuses like Profibus, WorldFIP and CAN, various electro...

  1. Advances in impact resistance testing for explosion-proof electrical equipment

    Directory of Open Access Journals (Sweden)

    Pasculescu Vlad Mihai

    2017-01-01

    Full Text Available The design, construction and exploitation of electrical equipment intended to be used in potentially explosive atmospheres presents a series of difficulties. Therefore, the approach of these phases requires special attention concerning technical, financial and occupational health and safety aspects. In order for them not to generate an ignition source for the explosive atmosphere, such equipment have to be subjected to a series of type tests aiming to decrease the explosion risk in technological installations which operate in potentially explosive atmospheres. Explosion protection being a concern of researchers and authorities worldwide, testing and certification of explosion-proof electrical equipment, required for their conformity assessment, are extremely important, taking into account the unexpected explosion hazard due to potentially explosive atmospheres, risk which has to be minimized in order to ensure the occupational health and safety of workers, for preventing material losses and for decreasing the environmental pollution. Besides others, one of the type tests, which shall be applied, for explosion-proof electrical equipment is the impact resistance test, described in detail in EN 60079 which specifies the general requirements for construction, testing and marking of electrical equipment and Ex components intended for use in explosive atmospheres. This paper presents an analysis on the requirements of the impact resistance test for explosion-proof electrical equipment and on the possibilities to improve this type of test, by making use of modern computer simulation tools based on finite element analysis, techniques which are widely used nowadays in the industry and for research purposes.

  2. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  3. Equipment; Equipements

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2005-07-15

    Four articles are gathered in this data sheet: they deal with 1) PAM's flow meter technology 2) ATHELIA traceability: a strategic challenge for the LPG market 3)A. SILVA MATOS changes its image and emerges into the energies 4) BLACKMER offers a full line of LPG equipment for the transfer of propane, butane and anhydrous ammonia. (authors)

  4. System for routine testing of self-contained and airline breathing equipment

    Energy Technology Data Exchange (ETDEWEB)

    McDermott, H.J.; Hermens, G.A.

    1980-07-01

    A system for routine testing of self-contained and airline breathing equipment, developed by Shell Oil Co., for testing breathing equipment at one of its refineries, consists of an 80 psig air supply for airline respirators; a 500-2100 psig air supply for self-contained units; a regulator test system which uses a mannequin head that simulates human inhalation and which tests the ability of the regulator to keep the mask interior at the correct positive pressure; and an exhalation valve test system which identifies a leaky or sticking valve. The testing system has been in use for about 30 mo and has led to increased acceptance of respiratory protective equipment by workers.

  5. Design of tracer tests equipment for the El Berrocal site, Spain

    International Nuclear Information System (INIS)

    Garcia Gutierrez, M.; Hernandez Benitez, A.; Yllera de Llano, A.; Bueno, J.

    1996-01-01

    This Topical Report contains the information concerning the design and manufacture of the instrumentation used for the large scale tracer tests performed at El Berrocal; as well as about the support infrastructure needed for the proper performance of the tests. One of the main objectives of the large scale Tracer Test was the design and development of an instrumentation and data acquisition equipment; that would allow the automatic and precise measurement and record of all the physical parameters important for this type of essays. This approach has represented a great change concerning the classical methodology used in this type of tests. Three boreholes from El Berrocal experimental site have been instrumented for this essay. Boreholes S-13 and S-15 for the tracer injections and boreholes S-2 for tracer recovery. In Pictures 1 and 2 can be observed the tripods installed on top of boreholes S-13 and S-15, both inclined (the first 30 degree and the second 20 degree). From the tripods' capstans hangs all the instrumentation placed inside the boreholes. For each boreholes there are sensors to be measured on the surface equipment, associated to magnitudes registered in the tracer injection or recirculation circuits; and a second group of sensors placed in depth and associated to each one of the packered isolated sections in which the borehole has been physically divided. Picture 3 shows the mine shaft. At the end of the gallery is placed borehole S-2, Picture 4. In this Topical Report will be separately detailed the development performed for the mechanical instrumentation inside the boreholes, the design concerning the electronic for measurement and automatic data recording, and the surface instrumentation for tracer injection and control. (Author)

  6. 40 CFR 86.1832-01 - Optional equipment and air conditioning for test vehicles.

    Science.gov (United States)

    2010-07-01

    ...) Except for air conditioning, where it is expected that 33 percent or less of a car line, within a test... air conditioning regardless of the rate of installation of air conditioning within the car line... Optional equipment and air conditioning for test vehicles. For test vehicles selected under §§ 86.1822-01...

  7. Maintenance cost control at the Pacific Missile Test Center.

    OpenAIRE

    Jenson, Richard J.

    1980-01-01

    Approved for public release; distribution is unlimited The Pacific Missile Test Center (PMTC) is the Navy's largest Major Range and Test Facility Base, with an investment of over one billion dollars. The majority of this investment is in range test equipment and facilities including radar, telemetry, communication and command/ control systems. Concern is growing over the "excessively obsolete condition of PMTC technical equipment." Improvement of factors concerned with...

  8. ENGINEERING DESIGN OPTIMIZATION OF HEEL TESTING EQUIPMENT IN THE EXPERIMENTAL VALIDATION OF SAFE WALKING

    Directory of Open Access Journals (Sweden)

    Cristiano Fragassa

    2017-06-01

    Full Text Available Experimental test methods for the evaluation of the resistance of heels of ladies' shoes in the case of impact loads are fully defined by International Organization for Standardization (ISO procedures that indicate all the conditions of experiment. A first Standard (ISO 19553 specifies the test method for determining the strength of the heels in the case of single impact. The result offers a valuation of the liability to fail under the sporadic heavy blows. A second Standard (ISO 19556 details a method for testing the capability of heels of women' shoes to survive to the repetition of small impacts provoked by normal walking. These Standards strictly define the features for two different testing devices (with specific materials, geometries, weights, etc. and all the experimental procedures to be followed during tests. On the contrary, this paper describes the technical solutions adopted to design one single experimental device able to perform impact testing of heels in both conditions. Joining the accuracy of mechanic movements with the speed of an electronic control system, a new and flexible equipment for the complete characterization of heels respect to (single or fatigue impacts was developed. Moreover a new level of performances in experimental validation of heel resistance was introduced by the versatility of the user-defined software control programs, able to encode every complex time-depending cycle of impact loads. Dynamic simulations permitted to investigate the impacts on heel in different conditions of testing, optimizing the machine design. The complexity of real stresses on shoes during an ordinary walk and in other common situations (as going up and downstairs was considered for a proper dimensioning.

  9. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar; Desenvolvimento de um sistema de monitoracao e diagnostico utilizando logica Fuzzy aplicado a valvulas de controle de processo do CEA - Centro Experimental Aramar

    Energy Technology Data Exchange (ETDEWEB)

    Porto Junior, Almir Carlos Soares

    2014-07-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009{sup th} by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  10. Experience in testing and inspection and maintenance of material handling equipments

    International Nuclear Information System (INIS)

    Sharma, M.L.

    2009-01-01

    All the Industries, Power Projects/Stations, Organizations engaged in the field of process of manufacturing, power generation, transportation, design, layout, manufacturing, and supply have to utilize material handling equipment, machinery tools tackles, lifting gears for performing their tasks/activities. The major role of the material handling equipments play an important role and a component of 40% of the total activities of the system/process to achieve targeted output with the reliability and quality is performed by material handling equipment and machineries. The material handling equipment shall have to be chosen/selected to suit the process requirement at times to be specifically designed inspected and tested to meet the specific requirement. These equipment/machineries/lifting gears have to undergo for the periodical inspection and testing to qualify for further use in a specified period. All those equipment and machinery to be used for material handling if not found satisfactory during inspection and testing or otherwise also shall be dismantled/stripped to the extent of inspection requirement of the components/sub components and maintenance repair shall have to be done to make them worthy for reuse after testing and inspection duly witnessed by competent authority

  11. Unsolved problems in applying U.S. regulatory guides to control system equipment

    International Nuclear Information System (INIS)

    Stade, R.E.

    1978-01-01

    Two current problems encountered when designing control systems to the United States Regulatory Guide requirements are discussed. They are: 1) Level of surge voltages that should be specified when procuring solid state control and instrumentation systems and equipment. 2) The approach to be used qualifying equipment that must meet the aging requirements. (author)

  12. Ways to control quality of electric equipment in the coal industry

    Energy Technology Data Exchange (ETDEWEB)

    Shipilov, A.D.; Nabokov, E.P.

    1982-01-01

    A structure is proposed for organization in the coal industry of a permanent service for controlling quality of electrical engineering equipment. A form was developed for introduction of recommendations to improve quality. Methods are suggested for evaluating the quality level as applied to specific tasks of controlling quality of the electrical equipment used in mining.

  13. Identification and Control Plan for Long Length Contaminated Equipment Receiver and Transport Trailers

    International Nuclear Information System (INIS)

    DALE, R.N.

    2000-01-01

    Long Length Contaminated Equipment Removal System Receiver Trailers and Transport Trailers require identification and control for the design, requirements and operations baseline documents. This plan serves as those controls for the subject trailers

  14. First test of a CMS DT chamber equipped with full electronics in a muon beam

    CERN Multimedia

    Jesus Puerta-Pelayo

    2003-01-01

    A CMS DT chamber of MB3 type, equipped with the final version of a minicrate (containing all on-chamber trigger and readout electronics), was tested in a muon beam for the first time. The beam was bunched in 25 ns spills, allowing an LHC-like response of the chamber trigger. This test confirmed the excellent performance of the trigger design.

  15. Discussion on seismic test method for electrical equipment in nuclear power plant

    International Nuclear Information System (INIS)

    Xu Jianfeng; Xu Jianping

    2012-01-01

    This paper describes the seismic test methods and requirements for electrical equipment in nuclear power plant. Advices and suggestions are provided based on the detail comparison and analysis of the international and national standards. It can be a reference for seismic testing engineers. (authors)

  16. Tactical Vehicle Climate Control Testing

    Science.gov (United States)

    2017-03-31

    Final 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Test Operations Procedure (TOP) 02-2-820 Tactical Vehicle Climate Control Testing 5a...provides procedures for determining the maximum performance climate control capability of tactical vehicles in a minimalist baseline configuration inside...PROCEDURE *Test Operations Procedure 02-2-820 31 March 2017 DTIC AD No. TACTICAL VEHICLE CLIMATE CONTROL TESTING Page Paragraph 1. SCOPE

  17. Controlling the quality of replacement parts in nuclear station, class 1E equipment

    International Nuclear Information System (INIS)

    Pierson, R.K.; Clemons, R.W.

    1984-01-01

    Nuclear station owners have traditionally purchased replacement parts for Class 1E equipment from the original supplier of the equipment. By this method, part and equipment quality could be maintained. In recent years, however, this traditional source of parts has continuously declined as an increasing number of original equipment suppliers stop producing Class 1E equipment or no longer stock parts for older equipment. When replacement parts for Class 1E equipment are not obtainable from the original suppliers, equipment owners have created a variety of methods for assuring the quality of parts obtained from other sources. A standard that provides direction and guidance for maintaining the quality of Class 1E equipment when repaired with parts from alternate sources is, therefore, needed to assure the methods in use are satisfactory and to alert the equipment owners to additional acceptable methods. The standard has now been proposed. IEEE Standard P934 (June, 1983 Draft): ''Requirements for Replacement Parts for Class 1E Equipment in Nuclear Power Generating Stations'' (Ref-3) consist of an introductory section followed by sections on part selection, procurement, replacement (including inspections and tests), non-conforming conditions and records. The proposed standard also includes a non-mandatory appendix on acceptable procurement methods and a summary intended to assist the user in selecting a proper procurement method

  18. Electrical equipment for heat loss compensation in control circuits

    International Nuclear Information System (INIS)

    Balint, I.; Hirean, I.

    1995-01-01

    In the normal working conditions of an isotopic separation equipment (temperature range of 25...30 o C), a H 2 S * 6 H 2 O crystalohydrate is being formed in saturated water solutions of H 2 S. A danger occurs that the impulse pipes become clogged with crystalohydrates. An electric device , which prevents the coating of the pipe interior by crystalohydrates in association with a heat-conducting cement, is described. Good results obtained with this procedure have led to extending their use to technological pipes as well

  19. The equipment access software for a distributed UNIX-based accelerator control system

    International Nuclear Information System (INIS)

    Trofimov, Nikolai; Zelepoukine, Serguei; Zharkov, Eugeny; Charrue, Pierre; Gareyte, Claire; Poirier, Herve

    1994-01-01

    This paper presents a generic equipment access software package for a distributed control system using computers with UNIX or UNIX-like operating systems. The package consists of three main components, an application Equipment Access Library, Message Handler and Equipment Data Base. An application task, which may run in any computer in the network, sends requests to access equipment through Equipment Library calls. The basic request is in the form Equipment-Action-Data and is routed via a remote procedure call to the computer to which the given equipment is connected. In this computer the request is received by the Message Handler. According to the type of the equipment connection, the Message Handler either passes the request to the specific process software in the same computer or forwards it to a lower level network of equipment controllers using MIL1553B, GPIB, RS232 or BITBUS communication. The answer is then returned to the calling application. Descriptive information required for request routing and processing is stored in the real-time Equipment Data Base. The package has been written to be portable and is currently available on DEC Ultrix, LynxOS, HPUX, XENIX, OS-9 and Apollo domain. ((orig.))

  20. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K.; Chapin, J. T.

    2010-11-01

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by a lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.

  1. Equipment for testing components of system of sodium circuit protection against liquid sodium leaks

    International Nuclear Information System (INIS)

    Bar, J.; Urbancik, L.

    1983-01-01

    The equipment consists of a first bin with a closure and heater and of a second bin with a funnel. Both bins are made of molten quartz and consist of a vessel with a neck and nozzle. The input and output of the inert gas lead into the vessel. The closure of the first bin is provided with a thermocouple thermometer. The tested parts are installed above the funnel and on it. The equipment may beused for a large number of tests without using complicated and costly sodium channels. (M.D.)

  2. Implementation of a quality control program of the equipment of the nuclear medicine services in Chile

    International Nuclear Information System (INIS)

    Astudillo, R.; Diaz, G.; Ferreira, A.; Garcia, M.; Hermosilla, A.; Pacheco, F.; Vasquez, M.; Coca, M.

    2014-08-01

    Now days in Chile there are more of 43 Nuclear Medicine centers; most of them have gamma cameras in order to study physiological process in diagnostic and treatment of patients pathologies. This requires having the equipment in optimal operating condition and it is ensured with quality control programs that are based on a series of tests relating to protocols, such as TECDOC-602 y AAPM No.6. Planar test often applied in gamma cameras including: spatial resolution, spatial linearity, sensitivity and uniformity. SPECT tests consider: tomography uniformity, rotation center tomography resolution and total performance. The tests in dose calibrator are: background measurement, accuracy, precision, linearity and reproducibility. The tests above require the use of radioactive sources and specific simulators patterns or phantom based on international standards such as The National Electrical Manufacturers Association (Nema), International Atomic Energy Agency (IAEA) and The American Association of Medical Physics (AAPM). In this work we carried out several tests of quality control in a Nuclear Medicine Center of Temuco and we propose to implement the applied methodology in others similar Chilean centers. (author)

  3. 47 CFR 90.475 - Operation of internal transmitter control systems in specially equipped systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control... Control Internal Transmitter Control Systems § 90.475 Operation of internal transmitter control systems in specially equipped systems. (a) An internal transmitter control system need not be designed to meet the...

  4. Design and realization of test system for testing parallelism and jumpiness of optical axis of photoelectric equipment

    Science.gov (United States)

    Shi, Sheng-bing; Chen, Zhen-xing; Qin, Shao-gang; Song, Chun-yan; Jiang, Yun-hong

    2014-09-01

    With the development of science and technology, photoelectric equipment comprises visible system, infrared system, laser system and so on, integration, information and complication are higher than past. Parallelism and jumpiness of optical axis are important performance of photoelectric equipment,directly affect aim, ranging, orientation and so on. Jumpiness of optical axis directly affect hit precision of accurate point damage weapon, but we lack the facility which is used for testing this performance. In this paper, test system which is used fo testing parallelism and jumpiness of optical axis is devised, accurate aim isn't necessary and data processing are digital in the course of testing parallelism, it can finish directly testing parallelism of multi-axes, aim axis and laser emission axis, parallelism of laser emission axis and laser receiving axis and first acuualizes jumpiness of optical axis of optical sighting device, it's a universal test system.

  5. Quality control of X-ray equipment in some hospitals of Las Tunas province in Cuba

    International Nuclear Information System (INIS)

    Rodriguez Gonzalez, Maykel

    2008-01-01

    This paper presents the results of the quality controls executed in 33 X-ray rooms of Las Tunas Province in Cuba. Specific tests for the X-ray generators, X-ray Tube, as well as the visualization systems and darkrooms were included. The results also include the estimation of patient doses for some standard radiographic projections (thorax, lumbar spine, abdomen, skull, and pelvis). The results of the evaluation of X-ray equipment was made following the procedures and tolerance included on the technical guidelines elaborated by the National Control Center of Medical Devices, which is the center for regulation of medical devices in the Republic of Cuba. Patient doses obtained were compared with the references levels reported in The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). (author)

  6. 76 FR 77914 - Energy Conservation Program for Certain Commercial and Industrial Equipment: Test Procedures for...

    Science.gov (United States)

    2011-12-15

    ... Energy Conservation Program for Certain Commercial and Industrial Equipment: Test Procedures for High... Illuminating Engineering Society of North America (IES), and the International Commission on Illumination... docket web page can be found at: http://www1.eere.energy.gov/buildings/appliance_standards/commercial...

  7. Testing of wet scrap recovery equipment for mixed oxide scrap reprocessing

    International Nuclear Information System (INIS)

    Demiter, J.A.; Klem, M.J.; Owen, T.J.

    1984-08-01

    The Wet Scrap Recovery (WSR) program was initiated at the Hanford Engineering Development Laboratory (HEDL) by Westinghouse Hanford Company in Richland, Washington to demonstrate fuel fabrication scrap recovery and reconversion to fuel grade oxide powder using the continuous coprecipitation-calcination (COPRECAL) conversion process. Advancements in process control equipment and instrumentation were also developed and demonstrated

  8. Operation JANGLE. Nevada Proving Grounds, October-November 1951. Tests of Service Equipment and Operation

    Science.gov (United States)

    1952-07-01

    No. 8-11 (June 19i51), p. 44. 9. Miscellaneous Gas Protective Equipment Var Department Technical Manual T10-290 (27 Miarch 1944), pp. 5 - 20, 10. Ibid...turned over to Project 6.7 for procesoing . 4.1.2 §watches and Clothin& Contaminated U Controlled Methods The fabric swatches and the woolen shirts

  9. 49 CFR 236.6 - Hand-operated switch equipped with switch circuit controller.

    Science.gov (United States)

    2010-10-01

    ... controller. 236.6 Section 236.6 Transportation Other Regulations Relating to Transportation (Continued... switch circuit controller. Hand-operated switch equipped with switch circuit controller connected to the point, or with facing-point lock and circuit controller, shall be so maintained that when point is open...

  10. New Developments in CNC and DNC Controller Equipment for the Shipbuilding Industry

    National Research Council Canada - National Science Library

    Belanger, Joseph W

    1978-01-01

    .... The ultimate goal of this development program was to produce controller equipment that would function in a DNC network and allow the end user to begin to achieve an "INTEGRATED MANUFACTURING APPROACH" process...

  11. Performance Test of the Salt transfer and Pellet fabrication of UCl{sub 3} Making Equipment for Electrorefining

    Energy Technology Data Exchange (ETDEWEB)

    Woo, M. S.; Jin, H. J.; Park, G. I.; Park, S. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The process to produce a uranium chloride salt includes two steps: a reaction process of gaseous chlorine with liquid cadmium to form the CdCl{sub 2} occurring in a Cd layer, followed by a process to produce UCl{sub 3} by the reaction of U in the LiCl-KCl eutectic salt and CdCl{sub 2}. Chemical reaction is next chlorination reaction; - Cd chlorination : Cd + Cl2 → CdCl{sub 2} - U chlorination : 3CdCl2 + 2U → 3Cd + 2UCl{sub 3} The apparatus for producing UCl{sub 3} consists of a chlorine gas generator, a uranium chlorinator, a Cd distiller, the pelletizer, a off-gas wet scrubber and a dry scrubber. Salt transfer system set among reactors to transfer salt at 500 .deg. C. The temperature of the reactants is maintained at about 600 .deg. C. After the reaction is completed in the uranium chlorinator, The Salt product is transferred to the Cd distiller to decrease residual Cd concentration in the salts, and then salt is transferred to the mould of pelletizer by a transfer system to fabricate pellet type salt. Performance test of the salt transfer and pellet fabrication of its equipment was tested in this work. Performance test of the salt transfer and pellet fabrication of UCl3 making equipment for Electrorefining carried out in this work. The result of equipment test is that melted salt at 600 .deg. C was easy transferred by salt transfer equipment heated at 500 .deg. C. In this time, salt transfer was carried out by argon gas pressurization at 3bar. When velocity of salt transfer was controlled under reduce pressure, velocity of salt transfer was difficult to control. And when salt pellet was fabricated by the mold of pelletizer heated at 90 .deg. C better than mold of pelletizer heated at 200 .deg. C because salt melted prevent leakage from mold of pelletizer.

  12. Handling and disposal of SP-100 ground test nuclear fuel and equipment

    International Nuclear Information System (INIS)

    Wilson, C.E.; Potter, J.D.; Hodgson, R.D.

    1990-05-01

    The post SP-100 reactor testing period will focus on defueling the reactor, packaging the various radioactive waste forms, and shipping this material to the appropriate locations. Remote-handling techniques will be developed to defuel the reactor. Packaging the spent fuel and activated reactor components is a challenge in itself. This paper presents an overview of the strategy, methods, and equipment that will be used during the closeout phase of nuclear testing

  13. Handling and disposal of SP-100 ground test nuclear fuel and equipment

    International Nuclear Information System (INIS)

    Wilson, C.E.; Potter, J.D.; Hodgson, R.D.

    1991-01-01

    The post SP-100 reactor testing period will focus on defueling the reactor, packaging the various radiactive waste forms, and shipping this material to the appropriate locations. Remote-handling techniques will be developed to defuel the reactor. Packaging the spent fuel and activated reactor components is a challenge in itself. This paper presents an overview of the strategy, methods, and equipment that will be used during the closeout phase of nuclear testing

  14. Simulation-based Testing of Control Software

    Energy Technology Data Exchange (ETDEWEB)

    Ozmen, Ozgur [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Nutaro, James J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sanyal, Jibonananda [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Olama, Mohammed M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-02-10

    It is impossible to adequately test complex software by examining its operation in a physical prototype of the system monitored. Adequate test coverage can require millions of test cases, and the cost of equipment prototypes combined with the real-time constraints of testing with them makes it infeasible to sample more than a small number of these tests. Model based testing seeks to avoid this problem by allowing for large numbers of relatively inexpensive virtual prototypes that operate in simulation time at a speed limited only by the available computing resources. In this report, we describe how a computer system emulator can be used as part of a model based testing environment; specifically, we show that a complete software stack including operating system and application software - can be deployed within a simulated environment, and that these simulations can proceed as fast as possible. To illustrate this approach to model based testing, we describe how it is being used to test several building control systems that act to coordinate air conditioning loads for the purpose of reducing peak demand. These tests involve the use of ADEVS (A Discrete Event System Simulator) and QEMU (Quick Emulator) to host the operational software within the simulation, and a building model developed with the MODELICA programming language using Buildings Library and packaged as an FMU (Functional Mock-up Unit) that serves as the virtual test environment.

  15. New Developments in CNC and DNC Controller Equipment for the Shipbuilding Industry

    Science.gov (United States)

    1978-06-01

    REAPS 5th Annual Technical Symposium Proceedings Paper No. 11: New Developments in CNC and DNC Controller Equipment For the Shipbuilding Industry U.S...National Shipbuilding Research Program REAPS 5th Annual Technical Symposium Proceedings Paper No. 11: New Developments in CNC and DNC Controller...currently responsible for designs of CNC and DNC systems. He has 15 years experience as a designer of industrial equipment and systems and has been an owner

  16. An open software system based on X Windows for process control and equipment monitoring

    International Nuclear Information System (INIS)

    Aimar, A.; Carlier, E.; Mertens, V.

    1992-01-01

    The construction and application of a configurable open software system for process control and equipment monitoring can speed up and simplify the development and maintenance of equipment specific software as compared to individual solutions. The present paper reports the status of such an approach for the distributed control systems of SPS and LEP beam transfer components, based on X Windows and the OSF/Motif tool kit and applying data modeling and software engineering methods. (author)

  17. The construction of standardised equipment expressly adapted to the different methods of radiation control

    International Nuclear Information System (INIS)

    Savouyaud, J.; Menoux, A.

    1960-01-01

    The authors show what general characteristics must have equipment designed for radiation control. This equipment must make possible the measurement of doses corresponding to 1/10 of the maximum permissible limit. It should be designed for a specific purpose, and finally it should be independent as far as possible. The authors review the different types of control which it is necessary to effect. (author) [fr

  18. Practices of Radiotherapy Equipment Quality Control in Radiotherapy Centers in Croatia

    International Nuclear Information System (INIS)

    Svabic, M.; Jurkovic, S.; Faj, D.; Kasabasic, M; Smilovic Radojcic, D.; Ivkovic, A.

    2008-01-01

    From the prescription to the delivery of a radiotherapy treatment, a team of professionals from a number of disciplines is involved. In this way significant potential for errors leading to an accidental exposure becomes apparent. Comprehensive quality assurance/quality control (QA/QC) programme to minimize such errors is, therefore, required. One aspect of QA/QC programme is quality control of the equipment. In this paper we present experiences in establishing QC procedures in our centers. Also differences in QC practices in Croatian radiotherapy centers are reviewed in the light of recommendations given by international reports and publications To obtain insight into the current employed protocols a questionnaire based on our QC protocols was made and it was sent to all radiotherapy institutions in Croatia. QC procedures and tools used, professionals involved, performance frequencies of the tests and tolerance/action levels are compared. All centers perform the great majority of QC tests, but some variations in the performance frequencies of QC tests and in personnel responsible for performing particular tests are found. Reviewing of QC practices and exchanging experience could help in evolving uniform protocol for QC procedures at national level.(author)

  19. Soundness confirmation through cold test of the system equipment of HTTR

    International Nuclear Information System (INIS)

    Ono, Masato; Shinohara, Masanori; Iigaki, Kazuhiko; Tochio, Daisuke; Nakagawa, Shigeaki; Shimazaki, Yosuke

    2014-01-01

    HTTR was established at the Oarai Research and Development Center of Japan Atomic Energy Agency, for the purpose of the establishment and upgrading of high-temperature gas-cooled reactor technology infrastructure. Currently, it performs a safety demonstration test in order to demonstrate the safety inherent in high-temperature gas-cooled reactor. After the Great East Japan Earthquake, it conducted confirmation test for the purpose of soundness survey of facilities and equipment, and it confirmed that the soundness of the equipment was maintained. After two years from the confirmation test, it has not been confirmed whether the function of dynamic equipment and the soundness such as the airtightness of pipes and containers are maintained after receiving the influence of damage or deterioration caused by aftershocks generated during two years or aging. To confirm the soundness of these facilities, operation under cold state was conducted, and the obtained plant data was compared with confirmation test data to evaluate the presence of abnormality. In addition, in order to confirm through cold test the damage due to aftershocks and degradation due to aging, the plant data to compare was supposed to be the confirmation test data, and the evaluation on abnormality of the plant data of machine starting time and normal operation data was performed. (A.O.)

  20. Survey of Equipment Quality Control in Radiotherapy Centers in Croatia: First Results

    International Nuclear Information System (INIS)

    Jurkovic, S.; Diklic, A.; Smilovic Radojcic, Dj.; Svabic, M.; Kasabasic, M.; Ivkovic, A.; Faj, D.

    2011-01-01

    accelerators and six simulators. Conventional simulators are also important part of radiotherapy equipment. For the purpose of this work we collected and statistically analyzed a large number of data obtained through measurements that were done on six simulators, some of them testing mechanical and some radiation accuracy. Regarding mechanical accuracy of the machines, results showed that crosshair intersection stability with collimator rotation was most frequently out of tolerance. Tests of radiation accuracy showed that rotation of treatment couch and gantry was troublesome. Over 20 % of the values obtained with these tests were over 2 mm. Also, machines equipped with a multileaf collimator have 25 % out-of-tolerance values for width of stripes in MLC grid test. Results are also divided in two categories within tolerance values having in mind that values between 1 - 2 mm are already a caution level. The light/radiation coincidence in symmetric and especially asymmetric fields is an important test due to frequent use of half-fields in radiotherapy. Overlapping or distinction in asymmetric fields can result in non-precise dose delivery therefore causing damage of organs at risk or low tumor control. 46.2 % of out-of-tolerance values on central axis for asymmetric fields seem to be quite significant. The values for symmetric fields are mostly in tolerance. Flatness and symmetry were checked using PTW QuickCheck Webline system for both photons (on two different depths) and electrons. Since the accuracy of this system is lower then checking radiation parameters in water phantom, tolerance values are increased a bit. Results showed great stability in symmetry value but also some out-of-tolerance values for flatness, especially for measurements for photons on larger depth. Some linear accelerators in Croatia (five of nine) are equipped with the system for portal imaging. Unfortunately, only two of them were suitable for measurements at the time of our collection of data. Tested

  1. Quality control of conventional diagnostic radiology equipment in Serbia and Montenegro

    International Nuclear Information System (INIS)

    Ciraj, O.; Kosutic, D.; Markovic, S.

    2003-01-01

    There are more than 1500 diagnostic X-ray tubes in service in Serbia and Montenegro. Diagnostic X-ray equipment is checked on annual basis. X-ray equipment Qc protocols have been adopted from several international standards and guidelines [1,2], which have been modified according our practice and measuring equipment. According our inventory, about one half of all installed units is used for conventional X-ray diagnostics, 10% are mobile units, 2% of all in units in operation are mammographic devices an another 2% are computed tomography units. In addition there are about 600 dental X-ray units, which is 36% of all units. It is worth mentioning that almost 30 % of all installed units have single-phase generators, another 25% are tree phase (six and twelve pulse) generators and nearly 9% are high frequency units. Majority of units was installed more than 25 years ago. The Quality Control (QC) in radiography is a central part of QA programme, which deals with equipment maintenance and monitoring. QA in diagnostic radiology is a mean of maintaining standards in imaging and working towards minimizing patient and staff doses. As a part of QA programme in diagnostic radiology, the performance characteristics of 96 conventional X-ray units were measured in six months period during 2003. The diagnostic units were located in hospitals all over the country. They represent 25% of the total conventional diagnostic units of the country. About one half of measured X-ray units were new-installed. QC program has positive effect on X-ray equipment performance in a period of a few years. It is essential to perform QC tests for all installed X-ray units at least on annual basis. This would lead to production of consistent X-ray images, with minimal retake rate and hence, will contribute to decreasing of the patient dose. Patient doses are determined by multitude factors which interact in very complicated manner. It is very important to perform real patient dose measurements in

  2. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    Energy Technology Data Exchange (ETDEWEB)

    BARNES, D.A.

    2000-06-01

    The purpose of this document is to describe tests performed to validate Revision 12.0 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be communicating to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab.

  3. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    International Nuclear Information System (INIS)

    BARNES, D.A.

    2000-01-01

    The purpose of this document is to describe tests performed to validate Revision 12.0 of the TMACS Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be communicating to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  4. Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  5. Technical manual: operation and equipment instructions for in situ impulse test

    International Nuclear Information System (INIS)

    1979-11-01

    This manual describes the test equipment and procedures for a new field test which determines the shear modulus of a soil deposit at strain levels equivalent to those experienced during actual earthquakes. Results from this test are typically used as input parameters to response analyses for evaluating local soil effects during earthquake shaking. The test employs a cross-hole wave propagation procedure with velocity transducers located in closely spaced adjacent borings. Clear, consistent, and repeatable data in all types of soil and a method of data reduction different from conventional geophysical first arrival techniques are unique aspects of this new test. In addition to describing the principles of the test and data reduction procedures, major discussions of the field procedures are also included. Detailed drilling and testing information is provided both for planning and executing a test program

  6. The research on information security technology for the industrial control system of special equipment

    International Nuclear Information System (INIS)

    Chen Ligang; Liu Hongye; Zhang Wei; Sun Jianying; Lan Peng; Dai Sidan

    2014-01-01

    With the rapid development of information technology in enterprise application, industrial control network and management network is becoming more and more closely linked. Development and application of special equipment control system from the traditional industrial control system, not considered when designing communication security problem mainly, therefore, the industrial control system opened at the same time, isolation control system and the outside was weakened, the safety problems of industrial control system had become more and more serious. The practical application combined with the special equipment control system, analysis and elaboration in view of security problems for the control network, also, provide appropriate security solutions for professional characteristics of industrial control network, design on process control system specially, provide security partition protection scheme, in order to improve security ability of industrial control system information. (authors)

  7. Designing an object-oriented scheme for accelerator equipment control

    International Nuclear Information System (INIS)

    Trofimov, N.N.

    1994-01-01

    The object-oriented analysis (OOA) and design (OOD) formalisms developed by Project Technology Inc. is presented in this report. The method was originated in 1979 with the analysis phase of a large real-time project at Lawrence Berkeley Laboratory and since that time has been used in several large-scale industrial projects. It is supported by the Teamwork CASE package from Cadre Technologies Inc. For introducing basic concepts and definitions of the OOA/OOD, a typical accelerator device example: remotely controllable power supply which is used to power magnets in an accelerator beam transfer line is used through out this report. 18 refs., 18 figs

  8. Obtention and application of recovery coefficients in SUV values to quality control in PET equipment

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cássio Miri; Sá, Lídia V. de; Santana, Priscila do Carmo; Mamede, Marcelo; Silva, Teógenes A. da, E-mail: cassio.miri@unifesp.br, E-mail: lidia@ird.gov.br, E-mail: mamede.mm@gmail.com, E-mail: silvata@cdtn.br [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Departmento de Diagnose por Imagem; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    The functional imaging technique Positron Emission Tomography (PET) using the radiopharmaceutical fluorodeoxyglucose ({sup 18}F-FDG) has been demonstrated an important role in the diagnosis and staging of cancer tumors. However, the standard uptake values (SUV) quantification of a 'lesion' or a hot spot is influenced by partial volume effects (PVE). This is particularly important for evaluating solid tumour response to therapy, where SUV quantification could indicate treatment efficiency. The objective of this study was to evaluate the efficiency of {sup 18}F-FDG uptake correction in two image quantification modes (SUVmaximum and SUVmedium) through recovery coefficients (RC) application. The NEMA/IEC Body Phantom simulator was used and tested for an activity ratio lesion to background of 4:1, and at different acquisition times. The images quantification was performed with OsiriX® software. The obtained RCs were applied to the phantom images. The obtained SUVmedium values corrected by RCs presented satisfactory results, demonstrating small differences (1.1% a 2.3%) in relation to previously known SUVreference values. This did not occur for corrected SUVmaximum values where differences of up to 27.0% were observed between these and SUVreference values. These results demonstrate that the PVE correction by SUVmedium can more adequate to evaluate tumor's uptake. Therefore, this parameter should be used for equipment quality control in order to evaluate the response and degree of agreement between equipment. (author)

  9. Development of wheelchair caster testing equipment and preliminary testing of caster models

    Directory of Open Access Journals (Sweden)

    Anand Mhatre

    2017-09-01

    Conclusion: The new caster test system has the capability to incorporate necessary test factors that degrade caster quality in LREs. Future work includes developing and validating a testing protocol that results in failure modes common during wheelchair use in LRE.

  10. Lunar ejecta and meteorites experiment. [characteristics and operation of test equipment installed during Apollo 17 flight to measure lunar ejecta particles

    Science.gov (United States)

    Berg, O. E.; Richardson, F. F.; Burton, H.

    1973-01-01

    The test equipment installed during the Apollo 17 flight to conduct the lunar ejecta and meteorites (LEAM) investigation is described. The LEAM experiment intercepts ejecta particles created by meteoroid impact on the lunar surface and records information useful in establishing the history of the moon. The deployment of the system in the Taurus-Littrow area and the method for controlling the equipment are explained. The effects of lunar surface temperatures on the operation of the sensors are reported.

  11. Application of owner technical management in hydraulic machinery and electrical equipment investment target control

    International Nuclear Information System (INIS)

    Luo, H

    2012-01-01

    Using technical means in investment target control is an effective method to improve investment benefit of a construction project. Take the practice of construction and management in hydropower station as an example, the investment and management need of the owner is put forward through the investment target decision-making process of electromechanical equipment. Owner technical management in the specific application measures and effects of investment target control was discussed in the paper, and the revelation in investment target control application of owner technical management was also summarized. The paper is aimed to provide a useful reference for the investment target control work in the construction of electromechanical equipment.

  12. Long-term preventive maintenance of instrumentation control equipment for PWR plants

    International Nuclear Information System (INIS)

    Sugitani, S.; Nanba, M.

    2006-01-01

    Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)

  13. The Variation Test and Extraction Equipment to Optimum Asphalt by Using Gasoline Solvent

    Science.gov (United States)

    Soehardi, Fitridawati

    2017-12-01

    Based on the Binamarga Specification 2010 at third revision, the extraction test should be carried out using the specimen from the loose asphalt mixture extracted from the back of the finisher bitumen machine. The purpose of this research is to find out the result of pretest and posttest extraction asphalt content. The Extraction test using two equipment, they are Soklet and Centrifuge. The specimens was used AMP, Asphalt Finisher and Core, which involved gasoline solvent. Based on the asphalt level extraction test results, the appropriate equipment was used centrifuge with the level accuracy as requirement of Binamarga Specification 2010 at third revision and the level of ease used as equipment in the field study. The asphalt content obtained for AMP 5,51%, Asphalt Finisher5,46% and Core 5.34%. As for the socket asphalt content obtained is AMP 5.55%, Asphalt Finisher 5.50% and Core core 5. 41%. The extract test value of asphalt content decreased, so it can be formulated KA JMF

  14. Cryogenic equipment to test models of superconducting magnets for accelerating-storage unit (ASU)

    International Nuclear Information System (INIS)

    Bondarenko, V.I.; Vasiliev, V.N.; Dinaburg, L.B.; Kalinin, V.V.; Katasonov, N.N.; Semenov, S.V.; Fokoeev, V.F.; Khrushchev, V.N.

    1986-01-01

    The paper describes the testing results of the cryogenic equipment to investigate 2-m models of ASU superconducting magnets in subcooled forces and pool-boiling cooling regimes. A special cryostat with radial helium bath supports is used for pool-boiling testing of 2-m models without magnetic screen. For forced flow testing of dipole models a cooling loop with a centrifugal helium pump is used providing the consumption up to 110 g/s and the head of 0.01 + 0.015 MPa with loop pressure 0.25 + 0.6 MPa and temperature 4.4 K

  15. Quality control for some digital fluoroscopy equipment used in Sudan

    International Nuclear Information System (INIS)

    Nayledam, A. I.

    2009-07-01

    The aim of this work was to perform quality control (QC) for six digital fluoroscopy units used for cardiovascular and interventional radiology procedures. Measurement were based on the QC protocol developed in the framework of European Commission (EU) DIMOND111 project. Measurement made included: beam quality (half-value layer, HVL), peak tube voltage (kVp) accuracy, automatic exposure control (Aec) and patient dose in terms of entrance surface air kerma rate plus image intensifier input air kerma rate. Dose measurements were made using Calibrated dose rate meter. Field limitation and source to skin distant measurement in addition to evaluation radiation protection tools for occupation exposure were performed. Image quality was evaluated in terms of spatial resolution and Contrast detail detectability. Patient dose measurements was performed using polymethylmethacrylate (PMMA) patient equivalent phantom whereas image quality was assessed using Haunter Type 53 spatial frequency grating and TO10 contrast detail phantom. The results show that the measured HVL and peak tube voltage were within the recommended limits of 10% in four fluoroscopy units. Entrance surface air kerma rate measured ranged from 6.1 to 250 mGy/min for fluoroscopy units operated in pulsed, continuous and cine mode of operation. These results were obtained using varying thicknesses of PMMA phantom. Most values are in reasonable agreement with internationally established reference levels with exception to one fluoroscopy unit where doses were remarkably high. Field limitation and minimum source to skin distance were well within the recommended limits of 30 cm for all fluoroscopy units. The limiting resolution was ranged from 1.0 to 2.2 Lp /mm for image intensifier field diameters between 7 ad 23 cm. The results of present study can be used as baseline for future quality assurance measurements. (Author)

  16. Catalytic converters for exhaust emission control of commercial equipment powered by internal combustion engines.

    Science.gov (United States)

    Cohn, J G

    1975-04-01

    The development of PTX, monolithic catalytic exhaust purifiers, is outlined, and their first use for exhaust emissions control of commercial equipment is described. The main use of PTX converters is on forklift trucks. The purification achievable with PTX-equipped fork-lift trucks under various operational conditions is discussed, and examples from the field are given. During more than ten years of operation, no adverse health effects have been reported, and PTX-equipped internal combustion engines appear safe for use in confined areas.

  17. Development of equipment qualification requirements for NPP instrumentation and control systems

    International Nuclear Information System (INIS)

    Siora, A. A.; Reshetitskij, S. V.; Harybin, A. V.

    2012-01-01

    The main stages of equipment qualification are presented. The aim of the work is to ensure compatibility between Ukrainian and international requirements. A comparison with US NRC requirements has been done. The approach in equipment qualification is presented for the resistance to: irradiation; dust; seismic motion, vibrations and mechanical impact; environmental impact (temperature, humidity, pressure); power supply parameters etc., as well as the technological testing

  18. Economic Analysis of Manure Harvesting Equipment in Feedyards for Dust Control

    OpenAIRE

    Bretz, Fran E.; Amosson, Stephen H.; Warminski, Patrick L.; Marek, Thomas H.

    2010-01-01

    This study concentrated on one method of dust control which is harvesting manure with equipment. An economic analysis including hourly fixed and operational costs were performed on the following: tractor-pulled box scraper, front-end loader, dump truck, spreader truck, elevating scraper and tractor-pulled end dump. The purpose of this study was to generate cost data for feedyard owners/operators to reference when making manure management and equipment purchasing decisions.

  19. A reliable fuzzy fault-tolerant automatic controller for nuclear plant equipment

    International Nuclear Information System (INIS)

    Rodriguez, R.J.; Liang, E.; Husseiny, A.A.; Sabri, Z.A.

    1989-01-01

    A reliable fuzzy fault-tolerant automatic controller (REFFTAC) has been designed for control of nuclear power equipment. The controller comprises an adaptive digital controller for on-line design of control actions based on analysis of input and output signals and a fuzzy controller as a backup system using a set of control rules based on operation experience. The controller is applied to a counter-flow heat exchanger. The applicability to control of nuclear reactor pumps is examined. A cost-benefit analysis is also provided. (orig.) [de

  20. Shifting Control Algorithm for a Single-Axle Parallel Plug-In Hybrid Electric Bus Equipped with EMT

    Directory of Open Access Journals (Sweden)

    Yunyun Yang

    2014-01-01

    Full Text Available Combining the characteristics of motor with fast response speed, an electric-drive automated mechanical transmission (EMT is proposed as a novel type of transmission in this paper. Replacing the friction synchronization shifting of automated manual transmission (AMT in HEVs, the EMT can achieve active synchronization of speed shifting. The dynamic model of a single-axle parallel PHEV equipped with the EMT is built up, and the dynamic properties of the gearshift process are also described. In addition, the control algorithm is developed to improve the shifting quality of the PHEV equipped with the EMT in all its evaluation indexes. The key techniques of changing the driving force gradient in preshifting and shifting compensation phases as well as of predicting the meshing speed in the gear meshing phase are also proposed. Results of simulation, bench test, and real road test demonstrate that the proposed control algorithm can reduce the gearshift jerk and the power interruption time noticeably.

  1. EMISSION TEST REPORT- FIELD TEST OF CARBON INJECTION FOR MERCURY CONTROL, CAMDEN COUNTY MUNICIPAL WASTE COMBUSTOR

    Science.gov (United States)

    The report gives results of parametric test to evaluate the injection powdered activated carbon to control volatile pollutants in municipal waste combustor (MWC) flue gas. he tests were conducted at a spray dryer absorber/electrostatic precipitator (SD/ESP)-equipped MWC in Camden...

  2. Characterization of particle bound organic carbon from diesel vehicles equipped with advanced emission control technologies.

    Science.gov (United States)

    Pakbin, Payam; Ning, Zhi; Schauer, James J; Sioutas, Constantinos

    2009-07-01

    A chassis dynamometer study was carried out by the University of Southern California in collaboration with the Air Resources Board (CARB) to investigate the physical, chemical, and toxicological characteristics of diesel emissions of particulate matter (PM) from heavy-duty vehicles. These heavy-duty diesel vehicles (HDDV) were equipped with advanced emission control technologies, designed to meet CARB retrofit regulations. A HDDV without any emission control devices was used as the baseline vehicle. Three advanced emission control technologies; continuously regenerating technology (CRT), zeolite- and vanadium-based selective catalytic reduction technologies (Z-SCRT and V-SCRT), were tested under transient (UDDS) (1) and cruise (80 kmph) driving cycles to simulate real-world driving conditions. This paper focuses on the characterization of the particle bound organic species from the vehicle exhaust. Physical and chemical properties of PM emissions have been reported by Biswas et al. Atmos. Environ. 2008, 42, 5622-5634) and Hu et al. (Atmos. Environ. 2008, submitted) Significant reductions in the emission factors (microg/mile) of particle bound organic compounds were observed in HDDV equipped with advanced emission control technologies. V-SCRT and Z-SCRT effectively reduced PAHs, hopanes and steranes, n-alkanes and acids by more than 99%, and often to levels below detection limits for both cruise and UDDS cycles. The CRT technology also showed similar reductions with SCRT for medium and high molecular weight PAHs, acids, but with slightly lower removal efficiencies for other organic compounds. Ratios of particle bound organics-to-OC mass (microg/g) from the baseline exhaust were compared with their respective ratios in diesel fuel and lubricating oil, which revealed that hopanes and steranes originate from lubricating oil, whereas PAHs can either form during the combustion process or originate from diesel fuel itself. With the introduction of emission control

  3. [Voluntary testing procedures of farm animal housing equipment according to the Animal Welfare Act of 1998].

    Science.gov (United States)

    Hesse, D; Knierim, U; von Borell, E; Herrmann, H; Koch, L; Müller, C; Rauch, H W; Sachser, N; Schwabenbauer, K; Zerbe, F

    1999-04-01

    Before its broad application in practice, housing equipment should be tested, in particular with regard to animal welfare. The differing positions of the German Federal Council (Bundesrat) and the German Federal Parliament (Bundestag), whether such testing should be mandatory or voluntary, have been conciliated in the amended animal welfare act by empowering the Federal Ministry of Food, Agriculture and Fisheries (BML) to fix official standards for voluntary testing procedures by regulation. On request of the BML, a report as scientific basis for a draft regulation is currently prepared by the scientific animal welfare committee of the German Agricultural Society (DLG). The scientific animal welfare committee has been appointed by the DLG in order to provide support in the effort to strengthen animal welfare aspects in the DLG-utility testing procedure of housing equipment, which is in place since 1953. The committee elaborates standards concerning testing methods, assessment criteria and the necessary size of investigations. As required, the scientific animal welfare committee may support the DLG-testing bodies in the implementation of the animal welfare part of the testing procedure. It will, moreover, be involved in the welfare assessment based on the testing results. The amendments of the already established testing procedure will help to fulfill the general requirements on an acceptable animal welfare testing procedure. While keeping in mind that there are certain limits in what can be achieved by a voluntary testing procedure, the enhanced consideration of animal welfare aspects within the DLG-utility testing procedure has the advantage to be relatively unbureaucratic and in line with EU legislation, and is, therefore, an appropriate tool for a contibrution to improved animal welfare in livestock housing.

  4. Bathymetry mapping using a GPS-sonar equipped remote control boat: Application in waste stabilisation ponds

    Science.gov (United States)

    Coggins, Liah; Ghadouani, Anas; Ghisalberti, Marco

    2014-05-01

    Traditionally, bathymetry mapping of ponds, lakes and rivers have used techniques which are low in spatial resolution, sometimes subjective in terms of precision and accuracy, labour intensive, and that require a high level of safety precautions. In waste stabilisation ponds (WSP) in particular, sludge heights, and thus sludge volume, are commonly measured using a sludge judge (a clear plastic pipe with length markings). A remote control boat fitted with a GPS-equipped sonar unit can improve the resolution of depth measurements, and reduce safety and labour requirements. Sonar devices equipped with GPS technology, also known as fish finders, are readily available and widely used by people in boating. Through the use of GPS technology in conjunction with sonar, the location and depth can be recorded electronically onto a memory card. However, despite its high applicability to the field, this technology has so far been underutilised. In the case of WSP, the sonar can measure the water depth to the top of the sludge layer, which can then be used to develop contour maps of sludge distribution and to determine sludge volume. The coupling of sonar technology with a remotely operative vehicle has several advantages of traditional measurement techniques, particularly in removing human subjectivity of readings, and the sonar being able to collect more data points in a shorter period of time, and continuously, with a much higher spatial resolution. The GPS-sonar equipped remote control boat has been tested on in excess of 50 WSP within Western Australia, and has shown a very strong correlation (R2 = 0.98) between spot readings taken with the sonar compared to a sludge judge. This has shown that the remote control boat with GPS-sonar device is capable of providing sludge bathymetry with greatly increased spatial resolution, while greatly reducing profiling time. Remotely operated vehicles, such as the one built in this study, are useful for not only determining sludge

  5. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    International Nuclear Information System (INIS)

    WANDLING, R.R.

    1999-01-01

    The purpose of this document is to describe tests performed to validate Revision 11.2 of the TMACS Monitor and Control System (TMCACS) and verify that the software functions as intended by design. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  6. Human factors evaluation of the engineering test reactor control room

    International Nuclear Information System (INIS)

    Banks, W.W.; Boone, M.P.

    1981-03-01

    The Reactor and Process Control Rooms at the Engineering Test Reactor were evaluated by a team of human factors engineers using available human factors design criteria. During the evaluation, ETR, equipment and facilities were compared with MIL-STD-1472-B, Human Engineering design Criteria for Military Systems. The focus of recommendations centered on: (a) displays and controls; placing displays and controls in functional groups; (b) establishing a consistent color coding (in compliance with a standard if possible); (c) systematizing annunciator alarms and reducing their number; (d) organizing equipment in functional groups; and (e) modifying labeling and lines of demarcation

  7. Large Scale Leach Test Facility: Development of equipment and methods, and comparison to MCC-1 leach tests

    International Nuclear Information System (INIS)

    Pellarin, D.J.; Bickford, D.F.

    1985-01-01

    This report describes the test equipment and methods, and documents the results of the first large-scale MCC-1 experiments in the Large Scale Leach Test Facility (LSLTF). Two experiments were performed using 1-ft-long samples sectioned from the middle of canister MS-11. The leachant used in the experiments was ultrapure deionized water - an aggressive and well characterized leachant providing high sensitivity for liquid sample analyses. All the original test plan objectives have been successfully met. Equipment and procedures have been developed for large-sample-size leach testing. The statistical reliability of the method has been determined, and ''bench mark'' data developed to relate small scale leach testing to full size waste forms. The facility is unique, and provides sampling reliability and flexibility not possible in smaller laboratory scale tests. Future use of this facility should simplify and accelerate the development of leaching models and repository specific data. The factor of less than 3 for leachability, corresponding to a 200,000/1 increase in sample volume, enhances the credibility of small scale test data which precedes this work, and supports the ability of the DWPF waste form to meet repository criteria

  8. Field testing of UF6 cylinder gamma-ray measuring equipment for international safeguards

    International Nuclear Information System (INIS)

    Fields, L.W.; Ricci, E.

    1982-01-01

    Two portable intrinsiIAEA (high-purity) Germanium (HP Ge) detectors, a Davidson portable multichannel analyzer (MCA), and accessory equipment were field-tested on product and feed UF 6 cylinders at the Oak Ridge Gaseous Diffusion Plant. These latter two instruments were not available to UCC-ND at the time of the field tests were designed to assess the usefulness of the above equipment for safeguards; specifically, each cylinder's average 235 U assay was determined by gamma spectrometry and the results were compared statistically with assays obtained previously by mass spectrometry for the same cylinders. This comparison was pivotal to show that the HP Ge detectors can produce results acceptable statistically, and that they can be used with confidence in field measurements. The portable HP Ge detectors are rugged for field use and are most useful in determining 235 U enrichment in UF 6 cylinders during international safeguards inspections at enrichment plants. Aside from their high resolution and light weight, they can be stored and transported at ambient temperatures. The latter results in a reduction of storage and handling costs for the IAEA inspector, in comparison with the use of high resolution lithium-drifted Ge detectors. The MCA and the accessory equipment also performed reliably. It is concluded that, although the Davidson portable MCA performed reliably, a higher degree of portability and electronic versatility would be desirable to assist the IAEA inspector in the field. Equipment such as the compact MCA recently developed by Los Alamos National Laboratory and/or the B-SAM developed by Brookhaven National Laboratory do have these features and, as such, would be more useful to the IAEC during field measurements. These field tests, but prototypes are being tried and evaluated by the IAEA inspectorate. At this writing the first commercialunits are being marketed in the US

  9. Quality control for the equipment of Nuclear medicine: experience of the H.U. de la Princesa

    International Nuclear Information System (INIS)

    Espana, M.L.; Gracia, A.; Prieto, C.; Lopez F, P.

    1998-01-01

    The quality control of the equipment used in a nuclear medicine service is a fundamental aspect in the Quality Assurance Program that in the present time is starting in our hospital. the objective of this work is to present the internal protocol used, its problematic associated with its starting, and the results obtained in the quality control as of the gamma camera as of the activimeter. In addition to the equipment own to the nuclear medicine service it has been used a Cs-137 source and puppets for several purposes. The results obtained demonstrated the stability of the controlled parameters which has led us to a restating of the established periodicities in our internal protocol, over all for some constancy tests. (Author)

  10. Development of wheelchair caster testing equipment and preliminary testing of caster models.

    Science.gov (United States)

    Mhatre, Anand; Ott, Joseph; Pearlman, Jonathan

    2017-01-01

    Because of the adverse environmental conditions present in less-resourced environments (LREs), the World Health Organization (WHO) has recommended that specialised wheelchair test methods may need to be developed to support product quality standards in these environments. A group of experts identified caster test methods as a high priority because of their common failure in LREs, and the insufficiency of existing test methods described in the International Organization for Standardization (ISO) Wheelchair Testing Standards (ISO 7176). To develop and demonstrate the feasibility of a caster system test method. Background literature and expert opinions were collected to identify existing caster test methods, caster failures common in LREs and environmental conditions present in LREs. Several conceptual designs for the caster testing method were developed, and through an iterative process using expert feedback, a final concept and a design were developed and a prototype was fabricated. Feasibility tests were conducted by testing a series of caster systems from wheelchairs used in LREs, and failure modes were recorded and compared to anecdotal reports about field failures. The new caster testing system was developed and it provides the flexibility to expose caster systems to typical conditions in LREs. Caster failures such as stem bolt fractures, fork fractures, bearing failures and tire cracking occurred during testing trials and are consistent with field failures. The new caster test system has the capability to incorporate necessary test factors that degrade caster quality in LREs. Future work includes developing and validating a testing protocol that results in failure modes common during wheelchair use in LRE.

  11. [An automatic torque control system for a bicycle ergometer equipped with an eddy current brake].

    Science.gov (United States)

    Kikinev, V V

    2007-01-01

    The main elements of the loading device of a bicycle ergometer, including an eddy current brake and a torque sensor, are described. The automatic torque control system, which includes the loading device, is equipped with a stabilizing feedback controller that optimally approximates the closed-loop transfer function of the target model. The reduced transfer function model of the controller is of the fourth order. A method featuring a modulation-demodulation loop is suggested for implementation of the control system.

  12. The study of human bodies' impedance networks in testing leakage currents of electrical equipments

    Science.gov (United States)

    Zhang, Zhaohui; Wang, Xiaofei

    2006-11-01

    In the testing of electrical equipments' leakage currents, impedance networks of human bodies are used to simulate the current's effect on human bodies, and they are key to the preciseness of the testing result. This paper analyses and calculates three human bodies' impedance networks of measuring electric burn current, perception or reaction current, let-go current in IEC60990, by using Matlab, compares the research result of current effect thresholds' change with sine wave's frequency published in IEC479-2, and amends parameters of measuring networks. It also analyses the change of perception or reaction current with waveform by Multisim.

  13. Development of hot test equipment for advanced nuclear fuel cycle development in JNC

    International Nuclear Information System (INIS)

    Nomura, K.; Shibata, A.; Nemoto, S.; Aoshima, A.; Funasaka, H.

    2001-01-01

    JNC (Japan nuclear fuel cycle development institute) has been developing a mini centrifugal contactor. JNC has experience of the development of the RETF (Recycle equipment test facility; under construction at Tokai-works) type centrifugal contactor and the mini centrifugal contactor is designed on the basis of this knowledge. The followings were carried out in order to estimate the performance of the mini centrifugal contactor: functional test for evaluating basic performance of this extractor, acid-solvent test and uranium test for confirming that sufficient performance is attained. The results showed wide performance in comparison with the mini mixer settler used so far and it is expected that shortening in operating time and higher efficiency of extracting tests will be achieved. (author)

  14. Qualification of portable well test equipment for sour, low temperature service in the oil and gas industry

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, A.; Williamson, A.I.; Brown, R. [Ammonite Corrosion Engineering Inc., Calgary, AB (Canada)

    2010-07-01

    Production well testing is now increasingly used in deeper, deviated wells with high pressures and temperatures. In order to verify the acceptability of production well testing equipment, the inspection industry uses standards and recommended practices within the API, ASTM, and NACE. The NACE standard MR0175 : sulphide stress cracking resistant metallic materials for oilfield equipment has recently been incorporated with ISO standard 15156. However, there are no guidelines or recognized industry standards for qualifying production well testing equipment in sour, low temperature service. This paper provided a reference source for the qualification of new and existing production well testing equipment in sour environments. The aim of the paper was to outline elements required for the development of a new standard. The guide included a history of sour service materials, and a discussion of low temperature properties. Well testing equipment was described, and examples of non-conformance were presented. 5 refs., 10 figs.

  15. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  16. Development of wheelchair caster testing equipment and preliminary testing of caster models

    OpenAIRE

    Mhatre, Anand; Ott, Joseph; Pearlman, Jonathan

    2017-01-01

    Background: Because of the adverse environmental conditions present in less-resourced environments (LREs), the World Health Organization (WHO) has recommended that specialised wheelchair test methods may need to be developed to support product quality standards in these environments. A group of experts identified caster test methods as a high priority because of their common failure in LREs, and the insufficiency of existing test methods described in the International Organization for Standar...

  17. Study concerning the power plant control and safety equipment by integrated distributed systems

    International Nuclear Information System (INIS)

    Optea, I.; Oprea, M.; Stanescu, P.

    1995-01-01

    The paper deals with the trends existing in the field of nuclear control and safety equipment and systems, proposing a high-efficiency integrated system. In order to enhance the safety of the plant and reliability of the structure system and components, we present a concept based on the latest computer technology with an open, distributed system, connected by a local area network with high redundancy. A modern conception for the control and safety system is to integrate all the information related to the reactor protection, active engineered safeguard and auxiliary systems parameters, offering a fast flow of information between all the agencies concerned so that situations can be quickly assessed. The integrated distributed control is based on a high performance operating system for realtime applications, flexible enough for transparent networking and modular for demanding configurations. The general design considerations for nuclear reactors instrumentation reliability and testing methods for real-time functions under dynamic regime are presented. Taking into account the fast progress in information technology, we consider the replacement of the old instrumentation of Cernavoda-1 NPP by a modern integrated system as an economical and efficient solution for the next units. (Author) 20 Refs

  18. Control and management of energy in a PV system equipped with batteries storage

    Directory of Open Access Journals (Sweden)

    Kamal Hirech

    2016-06-01

    Full Text Available In this paper we present a work concerning the conception, implementation and testing of a photovoltaic system that is equipped with a new concept of control and manage the energy in a PV system with a battery storage. The objective is to exploit the maximum of power using Hill climbing improved algorithm that considers optimal electrical characteristics of PV panels regardless of the system perturbation, to manage the energy between blocs of PV system in order to control the charge/discharge process and inject the energy surplus into the grid and also to estimate the state of charge with precision. Moreover, the system guarantees the acquisition and presentation of results on computer, supervision and so on. The results obtained show the robustness of the PV system, good control and protection of batteries under the maximum of energy provided by the PV panels. The state of charge estimation is evaluated by using measured parameters in real time; it shows an improvement of around 5% compared to the conventional technique.

  19. Test module development to detect the flase call probe pins on microeprocessor test equipment

    Science.gov (United States)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    Probe pins are useful for electrical testing of microelectronic components, printed circuit board assembly (PCBA), microprocessors and other electronic devices due to it provides the conductivity test based on specific device circuit design. During the repeatable test runs, the load of test modules, contact failures and the current conductivity induces layer wear off all the tip of probe pins contact. Contamination will be build-up on probe pins and increased contact resistivity which results of cost loss and time loss for rectifying programs, rectifying testers and exchanging new probe pins. In this study, a resistivity approach will be developed to provide "Testing of Test Probes". The test module based on "Four-wire Ohm measurement" method with two alternative ways of applying power supply, that are 9V from a single power supply and 5V from Arduino UNO power supply were demonstrated to measure the small resistance value of microprocessor probe pin. A microcontroller with VEE Pro software was used to record the measurement data. The accuracy of both test modules were calibrated under different temperature conditions and result shows that 9V from a single power supply test module has higher measurement accuracy.

  20. Study of seismic response and vibration control of High voltage electrical equipment damper based on TMD

    Science.gov (United States)

    Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming

    2016-11-01

    Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.

  1. INCREASING OF ECOLOGICAL EFFICIENCY OF WORN EQUIPMENT BY PARTIAL UPDATES. ANALYTICAL AND CONTROL ASPECT

    Directory of Open Access Journals (Sweden)

    S. Voinova

    2017-12-01

    Full Text Available The current state of worn industrial equipment and the resulting low performance indicators of its functioning, in particular, low environmental friendliness, are considered. It is shown that the normalization of the complex situation that has developed in production is an acute problem, the solution of which should begin with the implementation of a program for the partial renewal of worn equipment. It is pointed out that there is a high potential for improving the technological, including ecological, efficiency of functioning of the upgraded equipment. It is pointed out that the partial renewal is highly efficient, because of the small specific investments in it. The significant influence of the quality of control of the setting and implementation of the renewal program on its effectiveness was noted. It is shown that the process of renewal of worn-out equipment, ultimately, has an environmental focus, increases the environmental friendliness of the updated technical facility.

  2. Development of a model and test equipment for cold flow tests at 500 atm of small nuclear light bulb configurations

    Science.gov (United States)

    Jaminet, J. F.

    1972-01-01

    A model and test equipment were developed and cold-flow-tested at greater than 500 atm in preparation for future high-pressure rf plasma experiments and in-reactor tests with small nuclear light bulb configurations. With minor exceptions, the model chamber is similar in design and dimensions to a proposed in-reactor geometry for tests with fissioning uranium plasmas in the nuclear furnace. The model and the equipment were designed for use with the UARL 1.2-MW rf induction heater in tests with rf plasmas at pressures up to 500 atm. A series of cold-flow tests of the model was then conducted at pressures up to about 510 atm. At 504 atm, the flow rates of argon and cooling water were 3.35 liter/sec (STP) and 26 gal/min, respectively. It was demonstrated that the model is capable of being operated for extended periods at the 500-atm pressure level and is, therefore, ready for use in initial high-pressure rf plasma experiments.

  3. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Emission Control System Performance... evaluation status of supported monitors (test complete/test not complete) in Mode $01 PID $01, as well as be... have the capability to include bi-directional communication for control of the evaporative canister...

  4. Earth Observing System (EOS)/ Advanced Microwave Sounding Unit-A (AMSU-A): Special Test Equipment. Software Requirements

    Science.gov (United States)

    Schwantje, Robert

    1995-01-01

    This document defines the functional, performance, and interface requirements for the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A) Special Test Equipment (STE) software used in the test and integration of the instruments.

  5. Status of NRC approval of EPRI electromagnetic interference susceptibility testing guidelines for digital equipment

    International Nuclear Information System (INIS)

    James, R.W.; Shank, J.W.; Yoder, C.

    1996-01-01

    Historically, nuclear power plants installing digital equipment have been required to conduct expensive, site-specific electromagnetic interference (EMI) surveys to demonstrate that EMI will not affect the operation of sensitive electronic equipment. Consequently, EPRI formed a Utility Working Group which developed a set of generic EMI susceptibility testing guidelines, which were published as an EPRI report in September 1994. These guidelines are based upon EMI survey data obtained from several different plants and include criteria for determining their applicability. The Working Group interacted with NRC staff to obtain NRC approval. In April 1996, the NRC issued a Safety Evaluation Report (SER) endorsing the guidelines as a valid means of demonstrating EMI compatibility. The issuance of this SER was conditional on issuing a revision to the EPRI EMI Guidelines. This paper summarizes the guidelines, the NRC SER, and the current status of Revision 1 to the report

  6. Strategy and implementation of resources control of key equipments in nuclear power plant

    International Nuclear Information System (INIS)

    Zha Qing

    2014-01-01

    The strategic resources of the construction of nuclear power plant, which include the main equipment of nuclear island, heavy forgings, the bottleneck equipment and strategic materials, is one of the key issues in the construction of nuclear power projects. The control of these strategic resources has become the focus of competition in industry and the major nuclear power groups are willing to fight for this huge advantages. The resource control strategies of key equipment of nuclear power projects are analyzed in this paper. This paper put forward specific measures and methods for the strategic resources control. By the application to a plurality of nuclear power engineering construction projects, these specific measures and methods achieved good results and will be with important guidance and reference for the construction of future nuclear power projects in China. (author)

  7. 46 CFR 133.45 - Tests and inspections of lifesaving equipment and arrangements.

    Science.gov (United States)

    2010-10-01

    ... of flotation equipment such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats... mechanisms; (3) The proper condition of flotation equipment such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats, buoyant apparatus, and associated equipment; (4) That each inflatable liferaft...

  8. Improvement of remote control system of automatic ultrasonic equipment for inspection of reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Cheong, Yong Moo; Jung, H. K.; Joo, Y. S.; Koo, K. M.; Hyung, H.; Sim, C. M.; Gong, U. S.; Kim, S. H.; Lee, J. P.; Rhoo, H. C.; Kim, M. S.; Ryoo, S. K.; Choi, C. H.; Oh, K. I

    1999-12-01

    One of the important issues related to the nuclear safety is in-service inspection of reactor pressure vessel (RPV). A remote controlled automatic ultrasonic method is applied to the inspection. At present the automatic ultrasonic inspection system owned by KAERI is interrupted due to degradation of parts. In order to resume field inspection new remote control system for the equipment was designed and installed to the existing equipment. New ultrasonic sensors and their modules for RPV inspection were designed and fabricated in accordance with the new requirements of the inspection codes. Ultrasonic sensors were verified for the use in the RPV inspection. (autho0008.

  9. An efficient model of an equipment loaded panel for active control design studies.

    Science.gov (United States)

    Aglietti, G S; Langley, R S; Rogers, E; Gabriel, S B

    2000-10-01

    An effective investigation of alternative control strategies for the reduction of vibration levels in satellite structures requires realistic, yet efficient, structural models to simulate the dynamics of the system. These models should include the effects of the sources, receivers, supporting structure, sensors, and actuators. In this paper, a modeling technique which meets these requirements is developed and some active control strategies are briefly investigated. The particular subject of investigation is an equipment-loaded panel and the equations of motion are derived using the Lagrange-Rayleigh-Ritz (LRR) approach. The various pieces of equipment on the panel are mounted on active or passive suspensions, and resonators are used to represent the internal dynamics of the mounted equipment. Control of the panel, which transmits vibrations from sources to receivers, is by means of piezoelectric patches and the excitation consists of dynamic loads acting on the equipment enclosures and/or directly on the panel. The control objective is to minimize the displacement at an arbitrary output location. The LRR model developed is verified against one produced by using the finite-element method. Finally, some initial controller design studies are undertaken to investigate and compare the effectiveness of different control strategies (e.g., minimization at the source, along the vibration path, or at the receiver).

  10. Mercury Control for Plants Firing Texas Lignite and Equipped with ESP-wet FGD

    Energy Technology Data Exchange (ETDEWEB)

    Katherine Dombrowski

    2009-12-31

    This report presents the results of a multi-year test program conducted as part of Cooperative Agreement DE-FC26-06NT42779, 'Mercury Control for Plants Firing Texas Lignite and Equipped with ESP-wet FGD.' The objective of this program was to determine the level of mercury removal achievable using sorbent injection for a plant firing Texas lignite fuel and equipped with an ESP and wet FGD. The project was primarily funded by the U.S. DOE National Energy Technology Laboratory. EPRI, NRG Texas, Luminant (formerly TXU), and AEP were project co-funders. URS Group was the prime contractor, and Apogee Scientific and ADA-ES were subcontractors. The host site for this program was NRG Texas Limestone Electric Generating Station (LMS) Units 1 and 2, located in Jewett, Texas. The plant fires a blend of Texas lignite and Powder River Basin (PRB) coal. Full-scale tests were conducted to evaluate the mercury removal performance of powdered sorbents injected into the flue gas upstream of the ESP (traditional configuration), upstream of the air preheater, and/or between electric fields within the ESP (Toxecon{trademark} II configuration). Phases I through III of the test program, conducted on Unit 1 in 2006-2007, consisted of three short-term parametric test phases followed by a 60-day continuous operation test. Selected mercury sorbents were injected to treat one quarter of the flue gas (e.g., approximately 225 MW equivalence) produced by Limestone Unit 1. Six sorbents and three injection configurations were evaluated and results were used to select the best combination of sorbent (Norit Americas DARCO Hg-LH at 2 lb/Macf) and injection location (upstream of the ESP) for a two-month performance evaluation. A mercury removal rate of 50-70% was targeted for the long-term test. During this continuous-injection test, mercury removal performance and variability were evaluated as the plant operated under normal conditions. Additional evaluations were made to determine any

  11. Inspection of nuclear pressure equipment: principles, issues and perspectives; Le controle des equipements sous pression nucleaires: principes, enjeux et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Limousin, S. [Autorite de Surete Nucleaire (ASN), Dir. des Equipements sous Pression Nucleaires, 75 - Paris (France)

    2010-02-15

    French regulations about nuclear pressure equipment (like steam generators and the reactor pressure vessel) take into account hazards due to the energy contained in the equipment but also add specific requirements due for instance to the radioactivity or safety for instance. ASN is in charge of the conformity assessment of the most important equipment and monitors the licensee who is responsible of in service inspection and maintenance. Because of the internationalization of nuclear component manufacturing, and consequently new comers in this area, a careful monitoring of subcontractors is needed. The major anomalies detected in steam generator over the past few years showed the necessity of being careful and humble towards degradation mechanisms. Nuclear pressure equipment regulations enables ASN to perform an efficient oversight of licensees and component manufacturer in a context of international manufacturing and licence renewal. (author)

  12. The process control and management on equipment qualification of nuclear power plant

    International Nuclear Information System (INIS)

    Liu Dong; Wang Hongyin; Zhang Yong

    2013-01-01

    The equipment qualification (EQ) to the safety class equipment is an important safety measure for the nuclear power plants (NPP), and also reflects the nuclear safety culture. Along with the continuous constructions of NPP in China, it has become an important issue for NPP engineering company and equipment suppliers how to effectively establish standard EQ process control and management, and provide sufficient technical arrangements to maintain this EQ management system. This paper summarizes three process of EQ including Design Input, EQ Establishment and EQ Maintenance, proposes the measures and key points for EQ process control and management in phase of NPP construction, and introduces the documents management during the whole process of EQ. (authors)

  13. Establishment of an X radiation equipment quality control programme using non invasive meters

    International Nuclear Information System (INIS)

    Lucena, Rodrigo Ferreira de

    2010-01-01

    The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model Diavolt TM , and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests. (author)

  14. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  15. Decontamination tests of some materials used in installations and individual equipment

    International Nuclear Information System (INIS)

    Mestre, E.; Sautiez, N.; Kerdelleau, J. de

    1962-01-01

    After having indicated the definitions of some contamination and decontamination characteristics (susceptibility to contamination, decontamination gain, percentage of removed activity) and rankings used to assess chemical resistance to various chemical agents, this report contains results (resistance to contamination and chemical resistance) of decontamination and chemical tests performed on various materials: floor coatings, paints (vinyl-based, Epikote resin and urethane-based paint, and so on), peelable paints and coatings, individual materials and equipment (rubber, synthetic fibres, other textiles), materials (metals, ceramics, graphite and polythene)

  16. Development of In situ Geological Investigation and Test Equipment in KURT

    International Nuclear Information System (INIS)

    Koh, Yong Kweon; Kim, Kyung Su; Park, Kyung Woo; Koh, Yong Kweon; Choi, Jong Won

    2010-12-01

    For establishment of the advanced infrastructures of KURT, geological investigation and in situ test equipment were installed. The optical sensor technique could be applicable to monitoring system for the safe operation of various kinds of facilities having static and/or dynamic characteristics, such as chemical plant, pipeline, rail, huge building, long and slim structures, bridge, subway and marine vessel. etc. The micro-seismic monitoring system is able to predict the location and timing of fracturing of rock mass and rock fall around an underground openings as well as analysis on safety of various kinds of engineering structures such as nuclear facilities and other structures. The straddle packer system for hydro-testing in a deep borehole will lead to not only improve current technical level in the field of hydraulic testing but also provide important information to radioactive waste disposal technology development and site characterization project

  17. Investigation with automatic ultrasonic equipment to trace flaws in a large test piece, and experience gained in carrying out inspections

    International Nuclear Information System (INIS)

    Lindner, J.P.

    1975-01-01

    Based on the FRG codes providing guide lines for the Reactor Safety Commission regarding the size and location of flaws to be detected during in-service inspections, investigations were carried out into the possibility of detecting defects in thick-walled reactor pressure vessel components with the aid of ultrasonic inspection systems. A large test rig was used and, in a similar manner to the in-service inspections on a reactor, the tests were carried out with remote-controlled, automatically guided inspection equipment. For this purpose, a test specimen weighing about 10 tons was produced and provided with two weld seams having a large number of artificial defects. Essential parameters for the various reflectors in the test specimen were the size, location, angle and roughness or structure of the reflecting surfaces. As it is known that austenitic cladding has a considerable influence on flaw detection, the tests were undertaken first without cladding and then with cladding. A manipulator was designed for automatic remote-controlled inspection with which the inspection system travels on a meandering route over the area to be inspected. The inspection system employed was of the same type as the one used for baseline tests during external inspections of reactor vessel walls with parallel surfaces. Digital data collection was by a magnetic tape recorder designed to store both the data of the ultrasonic inspection system as well as the allied position data. The data stored on the tape are evaluated with electronic data processing programmes especially developed for this purpose. These programmes allow locally coherent indication patterns to be prepared, thus simplifying the interpretation of the data obtained. The author initially describes the equipment with the aid of which the studies were undertaken. A detailed discussion is then presented on the design of the test specimen and the inspection systems employed. Following this, the results obtained are explained and

  18. Flight test trajectory control analysis

    Science.gov (United States)

    Walker, R.; Gupta, N.

    1983-01-01

    Recent extensions to optimal control theory applied to meaningful linear models with sufficiently flexible software tools provide powerful techniques for designing flight test trajectory controllers (FTTCs). This report describes the principal steps for systematic development of flight trajectory controllers, which can be summarized as planning, modeling, designing, and validating a trajectory controller. The techniques have been kept as general as possible and should apply to a wide range of problems where quantities must be computed and displayed to a pilot to improve pilot effectiveness and to reduce workload and fatigue. To illustrate the approach, a detailed trajectory guidance law is developed and demonstrated for the F-15 aircraft flying the zoom-and-pushover maneuver.

  19. Building Controls Virtual Test Bed

    Energy Technology Data Exchange (ETDEWEB)

    2008-04-01

    The Building Controls Virtual Test Bed (BCVTB) is a modular software environment that is based on the Ptolemy II software environment. The BCVTB can be used for design and analysis of heterogenous systems, such as building energy and controls systems. Our additions to Ptolemy II allow users to Couple to Ptolemy II simulation software such as EnergyPlus, MATLAB/Simulink or Dymola for data exchange during run-time. Future versions of the BCVTS will also contain an interface to BACnet which is a communication protocol for building Control systems, and interfaces to digital/analog converters that allow communication with controls hardware. Through Ptolemy II, the BCVTB provides a graphical model building environment, synchronizes the exchanged data and visualizes the system evolution during run- time.

  20. PAT portable appliance testing : in-service inspection and testing of electrical equipment

    CERN Document Server

    Scaddan, Brian

    2015-01-01

    The Electricity at Work Regulations 1989 requires any electrical system to be constructed, maintained and used in such a manner as to prevent danger. This means that inspection and testing of systems, including portable appliances, is needed in order to determine if maintenance is required. This book explains in clear language what needs to be done and includes expert advice on legislation as well as actual testing. The book contains an appendix providing the electrical fundamentals needed by non-specialists and also has sample questions (with answers) for the C&G 2377 exam. It is also an ideal revision guide for the non-specialist, such as maintenance staff and caretakers who carry out these tasks part-time, alongside their many other duties.

  1. West Valley Demonstration Project vitrification process equipment Functional and Checkout Testing of Systems (FACTS)

    International Nuclear Information System (INIS)

    Carl, D.E.; Paul, J.; Foran, J.M.; Brooks, R.

    1990-01-01

    The Vitrification Facility (VF) at the West Valley Demonstration Project was designed to convert stored radioactive waste into a stable glass for disposal in a federal repository. The Functional and Checkout Testing of Systems (FACTS) program was conducted from 1984 to 1989. During this time new equipment and processes were developed, installed, and implemented. Thirty-seven FACTS tests were conducted, and approximately 150,000 kg of glass were made by using nonradioactive materials to simulate the radioactive waste. By contrast, the planned radioactive operation is expected to produce approximately 500,000 kg of glass. The FACTS program demonstrated the effectiveness of equipment and procedures in the vitrification system, and the ability of the VF to produce quality glass on schedule. FACTS testing also provided data to validate the WVNS waste glass qualification method and verify that the product glass would meet federal repository acceptance requirements. The system was built and performed to standards which would have enabled it to be used in radioactive service. As a result, much of the VF tested, such as the civil construction, feed mixing and holding vessels, and the off-gas scrubber, will be converted for radioactive operation. The melter was still in good condition after being at temperature for fifty-eight of the sixty months of FACTS. However, the melter exceeded its recommended design life and will be replaced with a similar melter. Components that were not designed for remote operation and maintenance will be replaced with remote-use items. The FACTS testing was accomplished with no significant worker injury or environmental releases. During the last FACTS run, the VF processes approximated the remote-handling system that will be used in radioactive operations. Following this run the VF was disassembled for conversion to a radioactive process. Functional and checkout testing of new components will be performed prior to radioactive operation

  2. Industry subsector analysis Australia: Air pollution control equipment. Export trade information

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-01

    The market survey covers the air pollution control equipment market in Australia. The analysis contains statistical and narrative information on projected market demand, end-users; receptivity of Australian consumers to U.S. products; the competitive situation, and market access (tariffs, non-tariff barriers, standards, taxes, distribution channels). It also contains key contact information.

  3. Quality control for dental X-rays equipment and film developers

    International Nuclear Information System (INIS)

    Pomares C, Martin

    1998-01-01

    Quality control in five dental X-ray equipments, film and film developers was done. It was for evaluating the radiologic practices in the odontologic services too. This work was made based on international standards, the results will be used for future works in quality assurance in dental radiology

  4. Nuclear material control and accountancy planning and performance testing

    International Nuclear Information System (INIS)

    Mike Enhinger; Dennis Wilkey; Rod Martin; Ken Byers; Brian Smith

    1999-01-01

    An overview of performance testing as used at U.S. Department of Energy facilities is provided. Performance tests are performed on specific aspects of the regulations or site policy. The key issues in establishing a performance testing program are: identifying what needs to be tested; determining how to test; establishing criteria to evaluate test results. The program elements of performance testing program consist of: planning; coordination; conduct; evaluation. A performance test may be conducted of personnel or equipment. The DOE orders for nuclear material control and accountancy are divided into three functional areas: program administration, material accounting, and material control. Examples performance tests may be conducted on program administration, accounting, measurement and measurement control, inventory, and containment [ru

  5. Air pollution control system testing at the DOE offgas components test facility

    International Nuclear Information System (INIS)

    Burns, D.B.; Speed, D.; VanPelt, W.; Burns, H.H.

    1997-01-01

    In 1997, the Department of Energy (DOE) Savannah River Site (SRS) plans to begin operation of the Consolidated Incineration Facility (CIF) to treat solid and liquid RCRA hazardous and mixed wastes. The Savannah River Technology Center (SRTC) leads an extensive technical support program designed to obtain incinerator and air pollution control equipment performance data to support facility start-up and operation. A key component of this technical support program includes the Offgas Components Test Facility (OCTF), a pilot-scale offgas system test bed. The primary goal for this test facility is to demonstrate and evaluate the performance of the planned CIF Air Pollution Control System (APCS). To accomplish this task, the OCTF has been equipped with a 1/10 scale CIF offgas system equipment components and instrumentation. In addition, the OCTF design maximizes the flexibility of APCS operation and facility instrumentation and sampling capabilities permit accurate characterization of all process streams throughout the facility. This allows APCS equipment performance to be evaluated in an integrated system under a wide range of possible operating conditions. This paper summarizes the use of this DOE test facility to successfully demonstrate APCS operability and maintainability, evaluate and optimize equipment and instrument performance, and provide direct CIF start-up support. These types of facilities are needed to permit resolution of technical issues associated with design and operation of systems that treat and dispose combustible hazardous, mixed, and low-level radioactive waste throughout and DOE complex

  6. The pharmaceutical vial capping process: Container closure systems, capping equipment, regulatory framework, and seal quality tests.

    Science.gov (United States)

    Mathaes, Roman; Mahler, Hanns-Christian; Buettiker, Jean-Pierre; Roehl, Holger; Lam, Philippe; Brown, Helen; Luemkemann, Joerg; Adler, Michael; Huwyler, Joerg; Streubel, Alexander; Mohl, Silke

    2016-02-01

    Parenteral drug products are protected by appropriate primary packaging to protect against environmental factors, including potential microbial contamination during shelf life duration. The most commonly used CCS configuration for parenteral drug products is the glass vial, sealed with a rubber stopper and an aluminum crimp cap. In combination with an adequately designed and controlled aseptic fill/finish processes, a well-designed and characterized capping process is indispensable to ensure product quality and integrity and to minimize rejections during the manufacturing process. In this review, the health authority requirements and expectations related to container closure system quality and container closure integrity are summarized. The pharmaceutical vial, the rubber stopper, and the crimp cap are described. Different capping techniques are critically compared: The most common capping equipment with a rotating capping plate produces the lowest amount of particle. The strength and challenges of methods to control the capping process are discussed. The residual seal force method can characterize the capping process independent of the used capping equipment or CCS. We analyze the root causes of several cosmetic defects associated with the vial capping process. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. EMISSION TEST REPORT, OMSS FIELD TEST ON CARBON INJECTION FOR MERCURY CONTROL

    Science.gov (United States)

    The report discusses results of a parametric evaluation of powdered activated carbon for control of mercury (Hg) emission from a municipal waste cornbustor (MWC) equipped with a lime spray dryer absorber/fabric filter (SD/FF). The primary test objectives were to evaluate the effe...

  8. Chlorine dioxide as a disinfectant for Ralstonia solanacearum control in water, storage and equipment

    Directory of Open Access Journals (Sweden)

    Popović Tatjana

    2016-01-01

    Full Text Available Brown rot or bacterial wilt caused by bacterium Ralstonia solanacearum is the main limiting factor in potato production. Quarantine measures are necessary to avoid spread of disease to disease-free areas. R. solanacearum has been shown to contaminate watercourses from which crop irrigation is then prohibited causing further potential losses in yield and quality. The bacteria also spread via surfaces that diseased seed potatoes come into contact with. This study showed bactericidal activity of chlorine dioxide (CIO2 on R. solanacearum for disinfection of water, surface and equipment. The results showed that CIO2 solution at concentration of 2 ppm at 30 minutes of exposure time had bactericidal effect for disinfection of water. For surface and equipment disinfection, concentration of 50 ppm showed total efficacy at 30 min and 5 sec exposure time, respectively. Results suggest that use of CIO2 as a disinfectant has a potential for control of brown rot pathogen in water, storage and equipment.

  9. The Mirror Fusion Test Facility cryogenic system: Performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1987-01-01

    The cryogenic system for the Mirror Fusion Test Facility (MFTF) is a 14-kW, 4.35-K helium refrigeration system that proved to be highly successful and cost-effective. All operating objectives were met, while remaining within a few percent of initial cost and schedule plans. The management approach used in MFTF allowed decisions to be made quickly and effectively, and it helped keep costs down. Manpower levels, extent and type of industrial participation, key aspects of subcontractor specifications, and subcontractor interactions are reviewed, as well as highlights of the system tests, operation, and present equipment status. Organizations planning large, high-technology systems may benefit from this experience with the MFTF cryogenic system

  10. New cryogenic facilities for testing superconducting equipments for the CERN Large Hadron Collider

    CERN Document Server

    Barth, K; Delikaris, D; Delruelle, N; Ferlin, G; Passardi, Giorgio; Rieubland, Jean Michel

    1998-01-01

    CERN's major project, the Large Hadron Collider (LHC), has moved to an implementation phase with machine construction to be completed by 2005. To achieve the design proton-proton centre of mass energy of 14 TeV in the given 27 km circumference LEP tunnel, the LHC will make an extensive use of high-field superconducting magnets using Nb-Ti filament operated at 1.9 K. In order to test, on the one han d, the superconducting cables of the magnets and, on the other hand, the expected performance of several of these magnets assembled in a string representing the lattice period of the machine (107 m lo ng), CERN has installed new cryogenic test facilities. The paper briefly describes these new facilities with all their associated equipments.

  11. Effects of Lumbar Spine Assemblies and Body-Borne Equipment Mass on Anthropomorphic Test Device Responses During Drop Tests.

    Science.gov (United States)

    Aggromito, Daniel; Jaffrey, Mark; Chhor, Allen; Chen, Bernard; Yan, Wenyi

    2017-10-01

    When simulating or conducting land mine blast tests on armored vehicles to assess potential occupant injury, the preference is to use the Hybrid III anthropomorphic test device (ATD). In land blast events, neither the effect of body-borne equipment (BBE) on the ATD response nor the dynamic response index (DRI) is well understood. An experimental study was carried out using a drop tower test rig, with a rigid seat mounted on a carriage table undergoing average accelerations of 161 g and 232 g over 3 ms. A key aspect of the work looked at the various lumbar spine assemblies available for a Hybrid III ATD. These can result in different load cell orientations for the ATD which in turn can affect the load measurement in the vertical and horizontal planes. Thirty-two tests were carried out using two BBE mass conditions and three variations of ATDs. The latter were the Hybrid III with the curved (conventional) spine, the Hybrid III with the pedestrian (straight) spine, and the Federal Aviation Administration (FAA) Hybrid III which also has a straight spine. The results showed that the straight lumbar spine assemblies produced similar ATD responses in drop tower tests using a rigid seat. In contrast, the curved lumbar spine assembly generated a lower pelvis acceleration and a higher lumbar load than the straight lumbar spine assemblies. The maximum relative displacement of the lumbar spine occurred after the peak loading event, suggesting that the DRI is not suitable for assessing injury when the impact duration is short and an ATD is seated on a rigid seat on a drop tower. The peak vertical lumbar loads did not change with increasing BBE mass because the equipment mass effects did not become a factor during the peak loading event.

  12. Evaluation of the revised training program for senior control room staff: science fundamentals and equipment principles

    International Nuclear Information System (INIS)

    Jervis, R.E.; Evans, G.J.

    1996-10-01

    Canadian nuclear utilities have formed an Inter-Utility Working Group to revise their program for training nuclear generating station senior control room staff, namely Control Room Operators and Shift Supervisors, in Science Fundamentals and Equipment Principles. This report documents the findings of an external review of this revision process, addressing, amongst other topics, the process of revision undertaken by the Working Group, their outline of topics to be included, and, the pertinence and comprehensiveness of the detailed training objectives identified for two of the courses. The approach to revising the program being followed by the Working Group appears to be reasonable insomuch that some training needs have been identified and used to construct detailed sets of training objectives. However, as assessed by the consultants without full documentation being available, some important steps appear to have been missed. Specifically, much of the basis of the revision process has not been documented, neither has the approach selected for the revision process, nor has any justification for not performing a CANDU specific job and task analysis been offered. Furthermore, the Working Group has not yet proposed any criteria for evaluation of the program or provided any test items. As a result, the consultants have had to develop criteria for evaluation of the overall program and of individual courses. These criteria were applied in a more detailed review of the training objectives for two particular courses: Plant Chemistry, and Nuclear Physics and Reactor Theory. Many of the training objectives for these courses were found to be too qualitative or ones that require trainees to memorize blocks of information rather than develop in them an ability to arrive at conclusions about scientific phenomena using principles and reasoning. This assessment indicates that the training objectives are designed to achieve too low a level of cognition, inconsistent with developing an

  13. Remote Access to Expensive SDRAM Test Equipment: Qimonda Opens the Shop-floor to Test Course Students

    Directory of Open Access Journals (Sweden)

    Ana C. Leão

    2007-08-01

    Full Text Available Remote labs are increasingly used in a variety of blended-learning scenarios, with the objective of complementing the work done in real labs. In such cases, the workbenches present in the real labs comprise a set of instruments that may be used over the internet. The lab work to be done by the students may be carried out from any location within or outside the campus, enabling them to carry out their assignments from home or from any other place, at a time of their choice. However, remote experimentation is not necessarily related to students accessing academic labs. Small and medium-size companies may be interested in specialised equipment available in university research labs (e.g. an electron microscope. Alternatively, student skills in various areas may be improved if they are able to work with equipment available in factories or other industry installations. This paper describes a collaboration initiative between the Qimonda SDRAM factory at Vila do Conde, in the vicinity of Porto, and the Faculty of Engineering of the University of Porto (FEUP, whereby an expensive test station used by Qimonda SDRAM factories is remotely accessible to test course students in higher-education institutions.

  14. Rolling contact fatigue in a vacuum test equipment and coating analysis

    CERN Document Server

    Danyluk, Michael

    2014-01-01

    This book deals with wear and performance testing of thin solid film lubrication and hard coatings in an ultra-high vacuum (UHV), a process which enables rapid accumulation of stress cycles compared with testing in oil at atmospheric pressure. The authors' lucid and authoritative narrative broadens readers' understanding of the benefits of UHV testing: a cleaner, shorter test is achieved in high vacuum, disturbance rejection by the deposition controller may be optimized for maximum fatigue life of the coating using rolling contact fatigue testing (RCF) in a high vacuum, and RCF testing in UHV

  15. 40 CFR 1068.415 - How do I test my engines/equipment?

    Science.gov (United States)

    2010-07-01

    ... POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR ENGINE PROGRAMS Selective Enforcement Auditing § 1068... for the year, you may test a minimum of one per 24-hour period. If you request and justify it, we may...

  16. Electromagnetic pulse/transient threat testing of protection devices for amateur/military affiliate radio system equipment. Volume 3. Test data, electromagnetic pulse testing of protection devices. Section 6. Equipment and devices bench check measurement

    Science.gov (United States)

    Bodson, D.; Frizzell, J.; Higdon, T.; Rabke, W.

    1985-10-01

    The results of two test programs are presented: one to evaluate existing transient suppression devices and components, and one to evaluate the response of amateur radio equipment to an EMP transient environment. Oscilloscope photographs of the following transmitters/receivers are included: YAESU FT 726R, YAESU F7 757GX, ICOM IC-745, ICOM IC-27A, ICOM IC-02AT, ICOM IC-271A, ICOM IC-471A, Kenwood TS-4305, Kenwood TR-2600, Kenwood 7930, and Swan 250.

  17. Development and assembly of equipment for non destructive assay system control using nuclear radiation

    International Nuclear Information System (INIS)

    Melo, Jose Altino Tupinamba

    2006-01-01

    Nondestructive Assay (NDA) is applied to machines and components quality tests. These elements would not have a good performance if they were conceived without concern about the mechanical project quality, used materials, manufacture processes and inspection and maintenance methodology. There are constant developments in high level of technology with the objective of guaranteeing the components quality and the good functioning of these machines, in the mechanics, naval, aeronautical, petrochemical and steel industry, energy and nuclear generation as well. The globalization in the industry lines is a fact, leading to an increase in the multinational projects and products. The following questions arise: how to assure the high quality of components and processes? How to optimize the test methods to assure that the materials do not have defects affecting the performance of the components? The answers to the questions above are found in the application of NDA. The complex materials analysis (inhomogeneous) using NDA requires a detailed study of the sensors response signal. In this work, a measure and control system of non destructive processes was developed, using a radioactive source with a defined energy in function of the material to be analyzed. This system involves: (a) Interface of input/output (I/O) (the Hardware) and (b) graphical Interface (Software). In the non destructive analysis, it is made the comparison of the signal proceeding from the sensor with a signal preset (Set Point) or analogical signal of reference (Base Line), which is adjusted in the I/O Interface. Analyzed the signal, the system will make the decision: (a) to reject or (b) to accept the analyzed material. The I/O Interface is implemented by electronic equipment with a MCS51. The purpose of this interface is to supply conditions to exchange information, using serial RS232, between the sensor and the microcomputer. The graphical Interface (software) is written in visual C++ language (author)

  18. The role of a certified calibration laboratory in a station's measuring and test equipment calibration, repair, and documentation program

    International Nuclear Information System (INIS)

    Ebenstreit, K.; MacIntosh, N.

    1995-01-01

    This paper outlines the role of a Certified Calibration Laboratory in- ensuring that the requirements of Measuring and Test Equipment calibration, identification, and traceability are met and documented. The Nuclear environment is one which is subject to influences from numerous 'quality agents'. One of the fields which comes under the scrutiny of the quality agents is that of equipment calibration and repair (both field components and M and TE). There is a responsibility to produce a superior product for the Ontario Consumer. The maintenance and calibration of Station Systems and their components have a direct impact on this output. The Measuring and Test Equipment element in each of these needs can be addressed by having a defined group of Maintenance Staff to execute a Measuring and Test Equipment Program which meets specific parameters. (author)

  19. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  20. Test of large-scale specimens and models as applied to NPP equipment materials

    International Nuclear Information System (INIS)

    Timofeev, B.T.; Karzov, G.P.

    1993-01-01

    The paper presents the test results on low-cycle fatigue, crack growth rate and fracture toughness of large-scale specimens and structures, manufactured from steel, widely applied in power engineering industry and used for the production of NPP equipment with VVER-440 and VVER-1000 reactors. The obtained results are compared with available test results of standard specimens and calculation relations, accepted in open-quotes Calculation Norms on Strength.close quotes At the fatigue crack initiation stage the experiments were performed on large-scale specimens of various geometry and configuration, which permitted to define 15X2MFA steel fracture initiation resistance by elastic-plastic deformation of large material volume by homogeneous and inhomogeneous state. Besides the above mentioned specimen tests in the regime of low-cycle loading, the test of models with nozzles were performed and a good correlation of the results on fatigue crack initiation criterium was obtained both with calculated data and standard low-cycle fatigue tests. It was noted that on the Paris part of the fatigue fracture diagram a specimen thickness increase does not influence fatigue crack growth resistance by tests in air both at 20 and 350 degrees C. The estimation of the comparability of the results, obtained on specimens and models was also carried out for this stage of fracture. At the stage of unstable crack growth by static loading the experiments were conducted on specimens of various thickness for 15X2MFA and 15X2NMFA steels and their welded joints, produced by submerged arc welding, in as-produced state (the beginning of service) and after embrittling heat treatment, simulating neutron fluence attack (the end of service). The obtained results give evidence of the possibility of the reliable prediction of structure elements brittle fracture using fracture toughness test results on relatively small standard specimens. 35 refs., 23 figs

  1. SPS/LEP beam transfer equipment control using industrial automation components

    International Nuclear Information System (INIS)

    Aimar, A.; Berard, G.; Bretin, J.L.; Carlier, E.; Dieperink, J.H.; Laffin, M.; Mertens, V.; Verhagen, H.

    1992-01-01

    Several control systems for SPS and LEP beam transfer equipment have to be commissioned in the near future. Tools for fast software development, easy maintenance and modifications, compliance with industrial standards, and independence of specific suppliers are considered to be essential. A large fraction of the systems can be realized using off-the-shelf industrial automation components like industrial I/O systems, programmable logic controllers, or diskless PCs. Specific electronics built up in G-64 can be integrated. Diskless systems running UNIX and X Windows are foreseen as process controllers and local access media. (author)

  2. Hot roller embossing system equipped with a temperature margin-based controller

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seyoung, E-mail: seyoungkim@kimm.re.kr; Son, Youngsu; Lee, Sunghee; Ham, Sangyong; Kim, Byungin [Department of Robotics and Mechatronics, Korea Institute of Machinery and Materials (KIMM), Daejeon (Korea, Republic of)

    2014-08-15

    A temperature control system was proposed for hot roller embossing. The roll surface was heated using induction coils and cooled with a circulating chilled water system. The temperature of the roll surface was precisely controlled by a temperature margin-based control algorithm that we developed. Implementation of the control system reduced deviations in the roll surface temperature to less than ±2 °C. The tight temperature control and the ability to rapidly increase and decrease the roll temperature will allow optimum operating parameters to be developed quickly. The temperature margin-based controller could also be used to optimize the time course of electrical power and shorten the cooling time by choosing an appropriate temperature margin, possibly for limited power consumption. The chiller-equipped heating roll with the proposed control algorithm is expected to decrease the time needed to determine the optimal embossing process.

  3. The Design and Implementation of the Remote Centralized-Monitoring System of Well-Control Equipment Based on RFID Technique

    Directory of Open Access Journals (Sweden)

    Luo Bin

    2017-01-01

    Full Text Available At present, in domestic for the management of well control equipment continue to the traditional way of nameplates identifies and paper-based registration, there are many issues like the separation of data information of device, easy lose, difficult query, confused management and many other problems, which will make the problem device into the well field, and then resulting in well control runaway drilling accident. To solve the above problems, this paper put forward to the integrated remote centralized-monitoring management mode of the well-control equipment. Taking the advantages of IOT technology, adopting the RFID technology, and combining with the remote transmission, this paper designs the remote centralized-monitoring system of well-control equipment based on RFID, which realizes the intelligent management of well-control equipment and meets the actual demand of the well-control equipment safe use and timely scheduling, and it has the ability of field application.

  4. MSAP Hardware Verification: Testing Multi-Mission System Architecture Platform Hardware Using Simulation and Bench Test Equipment

    Science.gov (United States)

    Crossin, Kent R.

    2005-01-01

    The Multi-Mission System Architecture Platform (MSAP) project aims to develop a system of hardware and software that will provide the core functionality necessary in many JPL missions and can be tailored to accommodate mission-specific requirements. The MSAP flight hardware is being developed in the Verilog hardware description language, allowing developers to simulate their design before releasing it to a field programmable gate array (FPGA). FPGAs can be updated in a matter of minutes, drastically reducing the time and expense required to produce traditional application-specific integrated circuits. Bench test equipment connected to the FPGAs can then probe and run Tcl scripts on the hardware. The Verilog and Tcl code can be reused or modified with each design. These steps are effective in confirming that the design operates according specifications.

  5. Full-scale Wind-tunnel and Flight Tests of a Fairchild 22 Airplane Equipped with a Fowler Flap

    Science.gov (United States)

    Dearborn, C H; Soule, H A

    1936-01-01

    Full-scale wind-tunnel and flight tests were made of a Fairchild 22 airplane equipped with a Fowler flap to determine the effect of the flap on the performance and control characteristics of the airplane. In the wind-tunnel tests of the airplane with the horizontal tail surfaces removed, the flap was found to increase the maximum lift coefficient from 1.27 to 2.41. In the flight test, the flap was found to decrease the minimum speed from 58.8 to 44.4 miles per hour. The required take-off run to attain an altitude of 50 feet was reduced from 935 feet to 700 feet by the use of the flap, the minimum distance being obtained with five-sixths full deflection. The landing run from a height of 50 feet was reduced one-third. The longitudinal and directional control was adversely affected by the flap, indicating that the design of the tail surfaces is more critical with a flapped than a plain wing.

  6. Equipping a glovebox for waste form testing and characterization of plutonium bearing materials

    International Nuclear Information System (INIS)

    Noy, M.; Johnson, S.G.; Moschetti, T.L.

    1997-01-01

    The recent decision by the Department of Energy to pursue a hybrid option for the disposition of weapons plutonium has created the need for additional facilities that can examine and characterize waste forms that contain Pu. This hybrid option consists of the placement of plutonium into stable waste forms and also into mixed oxide fuel for commercial reactors. Glass and glass-ceramic waste forms have a long history of being effective hosts for containing radionuclides, including plutonium. The types of tests necessary to characterize the performance of candidate waste forms include: static leaching experiments on both monolithic and crushed waste forms, microscopic examination, and density determination. Frequently, the respective candidate waste forms must first be produced using elevated temperatures and/or high pressures. The desired operations in the glovebox include, but are not limited to the following: (1) production of vitrified/sintered samples, (2) sampling of glass from crucibles or other vessels, (3) preparing samples for microscopic inspection and monolithic and crushed static leach tests, and (4) performing and analyzing leach tests in situ. This paper will describe the essential equipment and modifications that are necessary to successfully accomplish the goal of outfitting a glovebox for these functions

  7. Charge-Control Unit for Testing Lithium-Ion Cells

    Science.gov (United States)

    Reid, Concha M.; Mazo, Michelle A.; Button, Robert M.

    2008-01-01

    A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.

  8. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  9. Modeling and control of a variable-speed wind turbine equipped with permanent magnet synchronous generator

    Energy Technology Data Exchange (ETDEWEB)

    Aliprantis, D.C.; Papathanassiou, S.A.; Papadopoulos, M.P.; Kladas, A.G. [Purdue University, Electrical and Computer Engineering, West Lafayette, IN (United States)

    2000-08-01

    In this paper the operation of a variable-speed, stall regulated wind turbine equipped with a permanent magnet synchronous generator (PMSG) is examined. The emphasis is placed on the analysis of the electric part of the system, i.e. the electrical generator, the power electronics converters and the control. The operational characteristics of the machine are investigated through a series of computer simulations and the speed control system is designed to maximize the power output and achieve a smooth torque and power profile. (orig.)

  10. A Control Algorithm for Electric Vehicle Fast Charging Stations Equipped with Flywheel Energy Storage Systems

    DEFF Research Database (Denmark)

    Sun, Bo; Dragicevic, Tomislav; Freijedo Fernandez, Francisco Daniel

    2016-01-01

    This paper proposes a control strategy for plugin electric vehicle (PEV) fast charging station (FCS) equipped with a flywheel energy storage system (FESS). The main role of the FESS is not to compromise the predefined charging profile of PEV battery during the provision of a hysteresis-type active...... power ancillary service to the overhead power system. In that sense, when the active power is not being extracted from the grid, FESS provides the power required to sustain the continuous charging process of PEV battery. A key characteristic of the whole control system is that it is able to work without...

  11. Experience of Implementing a Distributed Control System for Thermal and Mechanical and Electrical Equipment at the South-West CHP

    Energy Technology Data Exchange (ETDEWEB)

    Babkin, K. V., E-mail: babkin@uztec.ru; Tsvetkov, M. S.; Kostyuk, R. I.; Chugin, A. V. [SC “South-West CHP” (Russian Federation); Bilenko, V. A.; Molchanov, K. A.; Fedunov, V. V. [JSC “Interautomatika” (Russian Federation)

    2015-01-15

    Results of implementing an SPPA-T3000-based unified distributed control system for thermal and mechanical and electrical equipment at the South-West CHP are discussed. Hardware solutions for integration with local control systems, control of electrical equipment in compliance with the standards IEC 61850, Modbus RTU, and communication between the plant control system and the System Operator of the Unified Power System are described.

  12. Remote System for Development, Implementation and Testing of Control Algorithms

    Directory of Open Access Journals (Sweden)

    Milan Matijevic

    2007-02-01

    Full Text Available Education in the field of automatic control requires adequate practice on real systems for better and full understanding of the control theory. Experimenting on real models developed exclusively for the purpose of education and gaining necessary experience is the most adequate and traditionally it requires physical presence in laboratories where the equipment is installed. Remote access to laboratories for control systems is a necessary precondition and support for implementation of the e learning in the area of control engineering. The main feature of the developed system is support for the development, implementation and testing of user defined control algorithms with remote controller laboratory. User can define control algorithm in some conventional programming language and test it using this remote system.

  13. Vehicle to Electric Vehicle Supply Equipment Smart Grid Communications Interface Research and Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Kevin Morrow; Dimitri Hochard; Jeff Wishart

    2011-09-01

    Plug-in electric vehicles (PEVs), including battery electric, plug-in hybrid electric, and extended range electric vehicles, are under evaluation by the U.S. Department of Energy's Advanced Vehicle Testing Activity (AVTA) and other various stakeholders to better understand their capability and potential petroleum reduction benefits. PEVs could allow users to significantly improve fuel economy over a standard hybrid electric vehicles, and in some cases, depending on daily driving requirements and vehicle design, PEVs may have the ability to eliminate petroleum consumption entirely for daily vehicle trips. The AVTA is working jointly with the Society of Automotive Engineers (SAE) to assist in the further development of standards necessary for the advancement of PEVs. This report analyzes different methods and available hardware for advanced communications between the electric vehicle supply equipment (EVSE) and the PEV; particularly Power Line Devices and their physical layer. Results of this study are not conclusive, but add to the collective knowledge base in this area to help define further testing that will be necessary for the development of the final recommended SAE communications standard. The Idaho National Laboratory and the Electric Transportation Applications conduct the AVTA for the United States Department of Energy's Vehicle Technologies Program.

  14. 46 CFR 199.45 - Tests and inspections of lifesaving equipment and arrangements.

    Science.gov (United States)

    2010-10-01

    ... such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats, buoyant apparatus, and..., immersion suits, work vests, lifefloats, buoyant apparatus, and associated equipment; (4) The proper...

  15. 47 CFR 2.956 - FCC inspection and submission of equipment for testing.

    Science.gov (United States)

    2010-10-01

    ... ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL RULES AND REGULATIONS Equipment Authorization Procedures... covered under the provisions of § 2.946. Telecommunication Certification Bodies (TCBs) ...

  16. ER-E4 regulation. Transitional arrangement to implement the rules for evaluating and state control of medical equipment

    International Nuclear Information System (INIS)

    2015-01-01

    Establish a regulatory document where the validity and status of the documents contained in the Regulatory Legal Base Technical Program of medical equipment is exposed, given the scope thereof to comply with the provisions of the Regulation. This regulation is aimed at all subjects (manufacturers or producers, suppliers or distributors, importers, users, medical equipment, as well as health institutions SNS) involved in activities related to the evaluation and control of the State Medical equipment and make use of complementary technical legal documents.

  17. Machinery and equipment for testing of valves; Maschinen und Anlagen fuer die Armaturenpruefung

    Energy Technology Data Exchange (ETDEWEB)

    Fuss, V.; Wuest, J. [EFCO-GmbH und Co. KG (Germany)

    2008-06-15

    Global industrial valve production totals more than $40 billion annually. These valves are used in conventional and nuclear power-generating plants, in chemicals and petrochemicals installations, in the sugar and paper industries, at shipyards and in a vast range of other industrial facilities, in all of which valve maintenance and valve testing are increasingly gaining in importance. The test systems described in the following article are suitable for testing to national and international standards of safety valves, knife and gate valves, butterfly valves, control valves and tank venting valves, for example, and also vessels, housings, pipes and other elements. (orig.)

  18. Evaluation of performance and quality control of high dose rate Ir-192 remote afterloading brachytherapy equipment

    International Nuclear Information System (INIS)

    Ahmed, M. A. M.

    2005-09-01

    Brachytherapy is the use of encapsulated radioactive sources to deliver a radiation dose at a short distance over a short time for treatment of malignant tumors. In Sudan, mainly in Radiation and Isotopes Center Khartoum (RICK) brachytherapy was introduced in 1989 using manual afterloading low dose rate 137 Cs for treatment of carcinoma of the cervix, but for safety reasons now it replace by high dose rate 192 Ir afterloading system (HDR) with remotely controlled device to deliver controlled radiation dose for treatment of carcinoma of cervix, esophagus and nasopharynx. This study was carried out in high dose rate 192 Ir afterloading brachytherapy equipment (Gamma Med 12i unit) located at RICK to evaluate the performance and to perform comprehensive quality control of the treatment unit with respect to three poles: safety systems, physical parameters and calibration of Ir-192 source through some quality control checks, so as to ensure that the equipment meets the safety standard. The study shows that all the safety systems which include the mechanical checks are work properly, the average of the dose rate measured at different positions from the treatment unit which represent the leakage radiation by using RDS-120 universal survey meter is less than 10μSv/h. The physical parameters which include the check of a source position accuracy by using x-OMAT ready pack film and catheter guide tube is I mm. The source strength that was obtained from the calibration procedures following the IAEA-TECDOC 1274 protocol by using HDR 1000 plus well type ionization chamber is different from the value of International Standard Laboratory by 1.5%. It was found that the brachytherapy equipment and the source used in brachytherapy meets the users requirements except some necessary requirements, so some recommendations was putted include these requirements.(Author)

  19. Replacement of the Advanced Test Reactor control room

    International Nuclear Information System (INIS)

    Durney, J.L.; Klingler, W.B.

    1990-01-01

    The control room for the Advanced Test Reactor has been replaced to provide modern equipment utilizing current standards and meeting the current human factors requirements. The control room was designed in the early 1960 era and had not been significantly upgraded since the initial installation. The replacement did not change any of the safety circuits or equipment but did result in replacement of some of the recorders that display information from the safety systems. The replacement was completed in concert with the replacement of the control room simulator which provided important feedback on the design. The design successfully incorporates computer-based systems into the display of the plant variables. This improved design provides the operator with more information in a more usable form than was provided by the original design. The replacement was successfully completed within the scheduled time thereby minimizing the down time for the reactor

  20. Acceptance test procedure for the master equipment list (MEL)database system -- phase I

    International Nuclear Information System (INIS)

    Jech, J.B.

    1997-01-01

    The Waste Remediation System/.../Facilities Configuration Management Integration group has requested development of a system to help resolve many of the difficulties associated with management of master equipment list information. This project has been identified as Master Equipment List (MEL) database system. Further definition is contained in the system requirements specification (SRS), reference 7

  1. Acceptance test procedure for the master equipment list (MEL)database system -- phase I

    Energy Technology Data Exchange (ETDEWEB)

    Jech, J.B.

    1997-04-10

    The Waste Remediation System/.../Facilities Configuration Management Integration group has requested development of a system to help resolve many of the difficulties associated with management of master equipment list information. This project has been identified as Master Equipment List (MEL) database system. Further definition is contained in the system requirements specification (SRS), reference 7.

  2. Equipment for fully homologous bulb turbine model testing in Laval University

    Science.gov (United States)

    R, Fraser; D, Vallée; Y, Jean; C, Deschênes

    2014-03-01

    Within the context of liberalisation of the energy market, hydroelectricity remains a first class source of clean and renewable energy. Combining the growing demand of energy, its increasing value and the appreciation associated to the sustainable development, low head sites formerly considered as non-profitable are now exploitable. Bulb turbines likely to equip such sites are traditionally developed on model using right angle transmission leading to piers enlargement for power take off shaft passage, thus restricting possibilities to have fully homologous hydraulic passages. Aiming to sustain good quality development on fully homologous scale model of bulb turbines, the Hydraulic Machines Laboratory (LAMH) of Laval University has developed a brake with an enhanced power to weight ratio. This powerful brake is small enough to be located in the bulb shell while dissipating power without mandatory test head reduction. This paper first presents the basic technology of this brake and its application. Then both its main performance capabilities and dimensional characteristics will be detailed. The instrumentation used to perform accurate measurements will be finally presented.

  3. NIF ICCS Test Controller for Automated and Manual Testing

    International Nuclear Information System (INIS)

    Zielinski, J S

    2007-01-01

    The National Ignition Facility (NIF) Integrated Computer Control System (ICCS) is a large (1.5 MSLOC), hierarchical, distributed system that controls all aspects of the NIF laser [1]. The ICCS team delivers software updates to the NIF facility throughout the year to support shot operations and commissioning activities. In 2006, there were 48 releases of ICCS: 29 full releases, 19 patches. To ensure the quality of each delivery, thousands of manual and automated tests are performed using the ICCS Test Controller test infrastructure. The TestController system provides test inventory management, test planning, automated test execution and manual test logging, release testing summaries and test results search, all through a web browser interface. Automated tests include command line based frameworks server tests and Graphical User Interface (GUI) based Java tests. Manual tests are presented as a checklist-style web form to be completed by the tester. The results of all tests, automated and manual, are kept in a common repository that provides data to dynamic status reports. As part of the 3-stage ICCS release testing strategy, the TestController system helps plan, evaluate and track the readiness of each release to the NIF facility

  4. Cursor Control Device Test Battery

    Science.gov (United States)

    Holden, Kritina; Sandor, Aniko; Pace, John; Thompson, Shelby

    2013-01-01

    The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not

  5. Los Alamos Controlled Air Incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    International Nuclear Information System (INIS)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-08-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawing, specifications, calculations, and costs. It aids duplication of the process at other facilities

  6. Controlled air incinerator for radioactive waste. Volume I. Rationale, process, equipment, performance, and recommendations

    International Nuclear Information System (INIS)

    Neuls, A.S.; Draper, W.E.; Koenig, R.A.; Newmyer, J.M.; Warner, C.L.

    1982-11-01

    This two-volume report is a detailed design and operating documentation of the Los Alamos National Laboratory Controlled Air Incinerator (CAI) and is an aid to technology transfer to other Department of Energy contractor sites and the commercial sector. Volume I describes the CAI process, equipment, and performance, and it recommends modifications based on Los Alamos experience. It provides the necessary information for conceptual design and feasibility studies. Volume II provides descriptive engineering information such as drawings specifications, calculations, and costs. It aids duplication of the process at other facilities

  7. Active seismic response control systems for nuclear power plant equipment facilities

    International Nuclear Information System (INIS)

    Kobori, Takuji; Kanayama, Hiroo; Kamagata, Shuichi

    1989-01-01

    To sustain severe earthquake ground motion, a new type of anti-seismic structure is proposed, called a Dynamic Intelligent Building (DIB) system, which is positioned as an active seismic response controlled the structure. The structural concept starts from a new recognition of earthquake ground motion, and the structural natural frequency is actively adjusted to avoid resonant vibration, and similarly the external counter-force cancels the resonant force which comes from the dynamic structural motion energy. These concepts are verified using an analytical simulator program. The advanced application of the DIB system, is the Active Supporting system and the Active Stabilizer system for nuclear power plant equipment facilities. (orig.)

  8. Periodic orbits of solar sail equipped with reflectance control device in Earth-Moon system

    Science.gov (United States)

    Yuan, Jianping; Gao, Chen; Zhang, Junhua

    2018-02-01

    In this paper, families of Lyapunov and halo orbits are presented with a solar sail equipped with a reflectance control device in the Earth-Moon system. System dynamical model is established considering solar sail acceleration, and four solar sail steering laws and two initial Sun-sail configurations are introduced. The initial natural periodic orbits with suitable periods are firstly identified. Subsequently, families of solar sail Lyapunov and halo orbits around the L1 and L2 points are designed with fixed solar sail characteristic acceleration and varying reflectivity rate and pitching angle by the combination of the modified differential correction method and continuation approach. The linear stabilities of solar sail periodic orbits are investigated, and a nonlinear sliding model controller is designed for station keeping. In addition, orbit transfer between the same family of solar sail orbits is investigated preliminarily to showcase reflectance control device solar sail maneuver capability.

  9. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    Bottaro, Marcio

    2012-01-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  10. A randomised controlled trial of cognitive aids for emergency airway equipment preparation in a Paediatric Emergency Department.

    Science.gov (United States)

    Long, Elliot; Fitzpatrick, Patrick; Cincotta, Domenic R; Grindlay, Joanne; Barrett, Michael Joseph

    2016-01-27

    Safety of emergency intubation may be improved by standardising equipment preparation; the efficacy of cognitive aids is unknown. This randomised controlled trial compared no cognitive aid (control) with the use of a checklist or picture template for emergency airway equipment preparation in the Emergency Department of The Royal Children's Hospital, Melbourne. Sixty-three participants were recruited, 21 randomised to each group. Equal numbers of nursing, junior medical, and senior medical staff were included in each group. Compared to controls, the checklist or template group had significantly lower equipment omission rates (median 30% IQR 20-40% control, median 10% IQR 5-10 % checklist, median 10% IQR 5-20% template; p sizing error rate was lower using a checklist or template (median 35 % IQR 30-45 % control, median 15% IQR 10-20% checklist, median 15% IQR 10-30% template; p < 0.05). The template group had less variation in equipment location compared to checklist or controls. There was no significant difference in preparation time in controls (mean 3 min 14 s sd 56 s) compared to checklist (mean 3 min 46 s sd 1 min 15 s) or template (mean 3 min 6 s sd 49 s; p = 0.06). Template use reduces variation in airway equipment location during preparation foremergency intubation, with an equivalent reduction in equipment omission rate to the use of a checklist. The use of a template for equipment preparation and a checklist for team, patient, and monitoring preparation may provide the best combination of both cognitive aids. The use of a cognitive aid for emergency airway equipment preparation reduces errors of omission. Template utilisation reduces variation in equipment location. Australian and New Zealand Trials Registry (ACTRN12615000541505).

  11. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  12. POC-scale testing of oil agglomeration techniques and equipment for fine coal processing

    Energy Technology Data Exchange (ETDEWEB)

    W. Pawlak; K. Szymocha

    1999-07-01

    The information presented in this manual is solely for the purpose of operating the POC-scale equipment for fine coal processing as described herein. This manual provides a general description of the process technology and guidelines for plant operating procedures. It is intended for use by the operators and maintenance personnel who will be responsible for the operations of the plant. No attempt should be made to operate the plant until the principles of the process and operating instructions contained in this manual are fully understood. Operating personnel should thoroughly familiarize themselves with all processing equipment prior to commencing plant operation. All equipment is skid mounted to provide a self-contained unit. The dimensions of the unit are comply with standard guidelines. A minimum distance of 2 feet is provided between equipment for walkway and maintenance.

  13. Quick setup of test unit for accelerator control system

    International Nuclear Information System (INIS)

    Fu, W.; D'Ottavio, T.; Gassner, D.; Nemesure, S.; Morris, J.

    2011-01-01

    Testing a single hardware unit of an accelerator control system often requires the setup of a program with graphical user interface. Developing a dedicated application for a specific hardware unit test could be time consuming and the application may become obsolete after the unit tests. This paper documents a methodology for quick design and setup of an interface focused on performing unit tests of accelerator equipment with minimum programming work. The method has three components. The first is a generic accelerator device object (ADO) manager which can be used to setup, store, and log testing controls parameters for any unit testing system. The second involves the design of a TAPE (Tool for Automated Procedure Execution) sequence file that specifies and implements all te testing and control logic. The sting third is the design of a PET (parameter editing tool) page that provides the unit tester with all the necessary control parameters required for testing. This approach has been used for testing the horizontal plane of the Stochastic Cooling Motion Control System at RHIC.

  14. CONTROL DE MALEZA EN DISTRITOS DE RIEGO CON EQUIPOS LIGEROS WEED CONTROL IN IRRIGATION DISTRICTS WITH LIGHT WEIGHT EQUIPMENT

    Directory of Open Access Journals (Sweden)

    José Ramón Lomelí Villanueva

    2010-12-01

    Full Text Available En México el control mecánico de maleza, tradicionalmente se realizaba con maquinaria inadecuada lo cual provocaba daños en los taludes y modificaciones de la sección hidráulica. Para resolver este problema, actualmente se utilizan los equipos ligeros que permiten el desarrollo de una cubierta vegetal, que no interfiere con el flujo del agua y su sistema radical retiene el suelo, lo cual reduce la erosión y mantiene en condiciones estables los taludes. El presente trabajo aborda los aspectos relativos a características y criterios para la selección de los implementos y la secuencia para su utilización. El costo de las operaciones para el control de maleza en canales, drenes y caminos se ha reducido un 39,21% con respecto a utilizar maquinaria inadecuada. La versatilidad de los equipos ligeros permite emplear el implemento más adecuado para cada tipo de maleza. En México, el inventario actual es de 263 equipos ligeros que tienen un potencial de aplicación para el control de la maleza, en la totalidad de los caminos, el 90% de canales y el 70% de drenes de los Distritos de Riego.In Mexico, the mechanical weed control was traditionally carried out with inadequate equipment which caused damage to the slopes and changes in the hydraulic section. In order to solve this problem, light weight equipment is currently being used to allow the development of a vegetation cover to retain soil with no interference with water flow, reducing erosion and maintaining stable conditions in the slopes. This paper addresses aspects related to characteristics and criteria for selecting and sequencing tools for use. The costs of weed control in irrigation channels, drains and roads have been reduced 39.21% compared to using inadequate equipment. The versatility of light weight equipment allows the use of the most appropriate implement for each weed. In Mexico, the current inventory includes 263 light weight devices with which a potential weed control of 90

  15. Optimal Active Power Control of A Wind Farm Equipped with Energy Storage System based on Distributed Model Predictive Control

    DEFF Research Database (Denmark)

    Zhao, Haoran; Wu, Qiuwei; Guo, Qinglai

    2016-01-01

    This paper presents the Distributed Model Predictive Control (D-MPC) of a wind farm equipped with fast and short-term Energy Storage System (ESS) for optimal active power control using the fast gradient method via dual decomposition. The primary objective of the D-MPC control of the wind farm...... is power reference tracking from system operators. Besides, by optimal distribution of the power references to individual wind turbines and the ESS unit, the wind turbine mechanical loads are alleviated. With the fast gradient method, the convergence rate of the DMPC is significantly improved which leads...... to a reduction of the iteration number. Accordingly, the communication burden is reduced. Case studies demonstrate that the additional ESS unit can lead to a larger wind turbine load reduction, compared to the conventional wind farm control without ESS. Moreover, the efficiency of the developed D-MPC algorithm...

  16. Interfacing the septa movement (DC motor) equipment to the PS control system and the MIL1553 bus

    CERN Document Server

    Dehavay, Claude

    1993-01-01

    Continuing the rejuvenation of the PS Control system , it is planned to replace the Single Transceiver Hybrid used to interface the Septa Movement Equipment by a G64 system connected to the VME crate via the MIL1553 bus. This note explains the G64 hardware interface and details the standard message as defined in the Control Protocole for Power Converter, RF and Stepping Motor equipment.

  17. Preparations for a train-to-train impact test of crash-energy management passenger rail equipment

    Science.gov (United States)

    2005-03-16

    Preparations are ongoing for a full-scale train-to-train : impact test of crash-energy management (CEM) equipment, : during which a cab car-led passenger consist, initially moving : at 30 mph, will impact a standing locomotive-led consist. The : coll...

  18. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    International Nuclear Information System (INIS)

    Mjoenes, L.

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure

  19. Longitudinal Control of a Platoon of Road Vehicles Equipped with Adaptive Cruise Control System

    Directory of Open Access Journals (Sweden)

    Zeeshan Ali Memon

    2012-07-01

    Full Text Available Automotive vehicle following systems are essential for the design of automated highway system. The problem associated with the automatic vehicle following system is the string stability of the platoon of vehicles, i.e. the problem of uniform velocity and spacing errors propagation. Different control algorithm for the longitudinal control of a platoon are discussed based on different spacing policies, communication link among the vehicles of a platoon, and the performance of a platoon have been analysed in the presence of disturbance (noise and parametric uncertainties. This paper presented the PID (Proportional Integral Derivative feedback control algorithm for the longitudinal control of a platoon in the presence of noise signal and investigates the performance of platoon under the influence of sudden acceleration and braking in severe conditions. This model has been applied on 6 vehicles moving in a platoon. The platoon has been analysed to retain the uniform velocity and safe spacing among the vehicles. The limitations of PID control algorithm have been discussed and the alternate methods have been suggested. Model simulations, in comparison with the literature, are also presented.

  20. 10 CFR 71.123 - Test control.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Test control. 71.123 Section 71.123 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) PACKAGING AND TRANSPORTATION OF RADIOACTIVE MATERIAL Quality Assurance § 71.123 Test control. The licensee, certificate holder, and applicant for a CoC shall establish a test...

  1. Minicomputer controlled test system for process control and monitoring systems

    International Nuclear Information System (INIS)

    Worster, L.D.

    A minicomputer controlled test system for testing process control and monitoring systems is described. This system, in service for over one year, has demonstrated that computerized control of such testing has a real potential for expanding the scope of the testing, improving accuracy of testing, and significantly reducing the time required to do the testing. The test system is built around a 16-bit minicomputer with 12K of memory. The system programming language is BASIC with the addition of assembly level routines for communication with the peripheral devices. The peripheral devices include a 100 channel scanner, analog-to-digital converter, visual display, and strip printer. (auth)

  2. A Novel Nonlinear Optimal Control Approach for the Dynamic Process of a Hybrid Electric Vehicle Equipped with Electromechanical Transmission

    Directory of Open Access Journals (Sweden)

    Changle Xiang

    2015-01-01

    Full Text Available Coordinatively controlling the engine and several motor/generators (MGs during a dynamic process is a challenging problem because they are coupled together by the electromechanical transmission (EMT system and all of them have strong nonlinear characteristics. We develop a novel nonlinear optimal control approach based on the multiobjective dynamic optimization model of the hybrid electric vehicle (HEV, which is equipped with an EMT system. In this approach, the current states of the components are obtained by using the state observation algorithm based on Kalman filtering; the future states of the components and the feasible region of the control variables are estimated by using the dynamic prediction algorithm based on the nonlinear model of the EMT system. Then, the control variables are achieved by using the optimal decision algorithm based on the hierarchical optimization and nonlinear programming, and the influence of the model error and the external disturbance are modified by using the feedback compensation algorithm. The simulation results illustrate the efficiency of the proposed control approach, and the test results verify its real-time performance.

  3. Equipment control in a sterile environment using the Gyromouse and a new interface, the user interface (UI) wand

    NARCIS (Netherlands)

    Stefels, C. N.; Kneissner, J.; Aarnink, R. G.; Kaufholz, P.; Grimbergen, C. A.; Dankelman, J.

    2007-01-01

    Providing the surgeon/interventionist with controlling devices that avoid the need for interference of an assistant could enable more direct control and reduce errors due to miscommunication or misinterpretation. Therefore the need for an input device controlling equipment from the sterile

  4. An Experimental Comparison of Two Methods Of Teaching Numerical Control Manual Programming Concepts; Visual Media Versus Hands-On Equipment.

    Science.gov (United States)

    Biekert, Russell

    Accompanying the rapid changes in technology has been a greater dependence on automation and numerical control, which has resulted in the need to find ways of preparing programers for industrial machines using numerical control. To compare the hands-on equipment method and a visual media method of teaching numerical control, an experimental and a…

  5. Tank Monitoring and Control System (TMACS) Acceptance Test Procedure

    International Nuclear Information System (INIS)

    HOLM, M.J.

    1999-01-01

    This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver devices. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  6. Occurrences in control room equipment, procedures and personnel performances: IRS control room events

    International Nuclear Information System (INIS)

    Tolstykh, V.

    1994-01-01

    The IAEA/NEA Incident Reporting System (IRS) was established in the early 1980, its objective being to gain from operating experience achieved in countries with nuclear power programmes by means of exchanging information on events relevant to safety. Among the 2171 events in the database, 175 events (i.e. 8%) were identified as ''control room events''. It was decided to group these into three sets for further study: 65 events with common mode/cause failures (CCFs), 22 events with cognitive errors and 30 events with unforeseen interaction between NPP systems. It is expected that the pitfalls experienced in the IRS and the questions derived from this study will help to gain a better understanding of the needs and interests of specialists in advanced information methods and artificial intelligence in NPP control rooms. (author)

  7. 75 FR 53457 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2010-08-31

    ... Coast Guard's oversight, to do work traditionally conducted by Coast Guard inspectors. In 1979, the... and shipboard equipment approvals, that permitting independent laboratories to do work under...: enclosed lifeboats, Sec. 160.135- be designed for use 7(b)(1)(i); by persons wearing Rescue immersion suits...

  8. RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response

    DEFF Research Database (Denmark)

    Hovgaard, Jens; Scott, Marian

    1997-01-01

    In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results...

  9. Gas Atomization Equipment Statement of Work and Specification for Engineering design, Fabrication, Testing, and Installation

    Energy Technology Data Exchange (ETDEWEB)

    Boutaleb, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pluschkell, T. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-30

    The Gas Atomization Equipment will be used to fabricate metallic powder suitable for Powder Bed Fusion additive Manufacturing material to support Lawrence Livermore National Laboratory (LLNL) research and development. The project will modernize our capabilities to develop spherical reactive, refractory, and radioactive powders in the 10-75 μm diameter size range at LLNL.

  10. Testing of the West Valley Vitrification Facility transfer cart control system

    International Nuclear Information System (INIS)

    Halliwell, J.W.; Bradley, E.C.

    1995-01-01

    Oak Ridge National Laboratory (ORNL) has designed and tested the control system for the West Valley Demonstration Project Vitrification Facility transfer cart. The transfer cart will transfer canisters of vitrified high-level waste remotely within the Vitrification Facility. The control system operates the cart under battery power by wireless control. The equipment includes cart-mounted control electronics, battery charger, control pendants, engineer's console, and facility antennas. Testing was performed in several phases of development: (1) prototype equipment was built and tested during design, (2) board-level testing was then performed at ORNL during fabrication, and (3) system-level testing was then performed by ORNL at the fabrication subcontractor's facility for the completed cart system. These tests verified (1) the performance of the cart relative to design requirements and (2) operation of various built-in cart features. The final phase of testing is planned to be conducted during installation at the West Valley Vitrification Facility

  11. Control systems field equipment forensics : what happened to my PLC and how do I fix it?

    Energy Technology Data Exchange (ETDEWEB)

    Parks, Raymond C.

    2010-10-01

    The outline for the presentation is: (1) Advance preparation - (a) Think about attacks before they happen, (b) Configuration Management, (c) Backups, (d) Off-site storage, (e) Design and build for resiliency, (f) Training operators to detect attack; (2) Detection - (a) How do I know I've been attacked, (b) The front-line detection system - operators; (3) Triage - (a) Working through the attack, (b) Law enforcement or business continuity, (c) Deciding what to fix first; (4) Field Equipment Forensics - (a) Engineering Workstation, (b) Projects/Configurations/Programs; and (5) Conclusion and Discussion. Red teaming works for supply chain - Finds the worst attacks across multiple dimensions, Shows where to best expend resources to reduce risk, and Provides positive control of potentially negative activities.

  12. Buying, supporting, maintaining software and equipment an IT manager's guide to controlling the product lifecycle

    CERN Document Server

    Gordon-Byrne, Gay

    2014-01-01

    INITIAL PRODUCT ACQUISITIONEquipment and Application AcquisitionIntroductionApplication Selection Dictates Hardware Selection     Background     Application License Acquisition     Going Naked     Operating System AcquisitionAcquisition Model: Direct from the Original Equipment Manufacturer     Platforms as Monopolies     Multiyear Commitments     Operating System and Machine Code License Lock-Ins     Strategic Partnerships     The Win Room     Credible CompetitionAcquisition Model: Channel Partners and Authorized Resellers     Competition between Partner or Channel Sources     Controlling Dis

  13. Positive train control test bed interoperability upgrades.

    Science.gov (United States)

    2013-02-01

    Transportation Technology Center, Inc. (TTCI) upgraded the Positive Train Control (PTC) Test Bed to support additional PTC testing configurations under Federal Railroad Administration (FRA) Task Order 270. The scope of work provided additional PTC Co...

  14. Approach to the assessment of the performance of nondestructive test methods in the manufacture of nuclear power station equipment

    International Nuclear Information System (INIS)

    Michaut, J.P.

    1996-01-01

    The safety of a nuclear power station lies largely in the possibility of ensuring, at the time of in service inspections on major equipment, that the extent of faults which may appear or develop is not greater than that of faults detrimental to behavior in service. This assurance is based on performance demonstration of the nondestructive test methods used for inspecting the equipment in service. This is the subject of numerous studies in various countries. To ensure that manufacturing faults likely to downgrade the safety of the equipment are not discovered in service, it seems desirable to make sure that the performance of the nondestructive test (NDT) methods which are going to be used in manufacture will be at least as high as those used in service and that they are therefore capable of guaranteeing detection of faults clearly less important than really harmful faults. The performance of NDT methods and their consistency with those which can be used in service is evaluated before the start of manufacture on a mock-up representative of the equipment itself. Information is given on research in progress on the bimetal welding of a pressurizer spray nozzle

  15. Flight Test Approach to Adaptive Control Research

    Science.gov (United States)

    Pavlock, Kate Maureen; Less, James L.; Larson, David Nils

    2011-01-01

    The National Aeronautics and Space Administration s Dryden Flight Research Center completed flight testing of adaptive controls research on a full-scale F-18 testbed. The validation of adaptive controls has the potential to enhance safety in the presence of adverse conditions such as structural damage or control surface failures. This paper describes the research interface architecture, risk mitigations, flight test approach and lessons learned of adaptive controls research.

  16. W-026 acceptance test plan plant control system hardware (submittal {number_sign} 216)

    Energy Technology Data Exchange (ETDEWEB)

    Watson, T.L., Fluor Daniel Hanford

    1997-02-14

    Acceptance Testing of the WRAP 1 Plant Control System Hardware will be conducted throughout the construction of WRAP I with the final testing on the Process Area hardware being completed in November 1996. The hardware tests will be broken out by the following functional areas; Local Control Units, Operator Control Stations in the WRAP Control Room, DMS Server, PCS Server, Operator Interface Units, printers, DNS terminals, WRAP Local Area Network/Communications, and bar code equipment. This document will contain completed copies of each of the hardware tests along with the applicable test logs and completed test exception reports.

  17. Ground test accelerator control system software

    International Nuclear Information System (INIS)

    Burczyk, L.; Dalesio, R.; Dingler, R.; Hill, J.; Howell, J.A.; Kerstiens, D.; King, R.; Kozubal, A.; Little, C.; Martz, V.; Rothrock, R.; Sutton, J.

    1988-01-01

    This paper reports on the GTA control system that provides an environment in which the automation of a state-of-the-art accelerator can be developed. It makes use of commercially available computers, workstations, computer networks, industrial 110 equipment, and software. This system has built-in supervisory control (like most accelerator control systems), tools to support continuous control (like the process control industry), and sequential control for automatic start-up and fault recovery (like few other accelerator control systems). Several software tools support these levels of control: a real-time operating system (VxWorks) with a real-time kernel (VRTX), a configuration database, a sequencer, and a graphics editor. VxWorks supports multitasking, fast context-switching, and preemptive scheduling. VxWorks/VRTX is a network-based development environment specifically designed to work in partnership with the UNIX operating system. A data base provides the interface to the accelerator components. It consists of a run time library and a database configuration and editing tool. A sequencer initiates and controls the operation of all sequence programs (expressed as state programs). A graphics editor gives the user the ability to create color graphic displays showing the state of the machine in either text or graphics form

  18. 10 CFR 72.162 - Test control.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Test control. 72.162 Section 72.162 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL... Test control. The licensee, applicant for a license, certificate holder, and applicant for a CoC shall...

  19. Standardized Laboratory Test Requirements for Hardening Equipment to Withstand Wave Impact Shock in Small High Speed Craft

    Science.gov (United States)

    2017-02-06

    Speed Craft by Michael R. Riley, The Columbia Group Heidi P. Murphy, NSWCCD Scott M. Petersen, NSWCCD Dr. Timothy W. Coats, NSWCCD...comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to...Standardized Laboratory Test Requirements for Hardening Equipment to Withstand Wave Impact Shock in Small High- Speed Craft 5a. CONTRACT NUMBER 5b

  20. Interfacing the septa movement (DC motors) equipment to the PS control system and the MIL1553 bus

    CERN Document Server

    Dehavay, Claude

    1995-01-01

    Continuing the rejuvenation of the PS Control system , this application replaces the Single Transceiver Hybrid used to interface the Septa Movement Fquipment by a G64 system connected to the VME crate via the MIL1553 bus. This note explains the G64 hardware interface and details the standard message as defined in the Control Protocole for Power Converter, RF and Stepping Motor equipment.

  1. Some auxiliary technology equipment for ATLAS hadron calorimeter module and submodule manipulations and the quality control of the assembled module

    International Nuclear Information System (INIS)

    Budagov, Yu.; Lebedev, A.; Lomakin, Yu.; Romanov, V.; Rusakovich, N.; Shchelchkov, A.; Sisakyan, A.; Sorokina, Yu.; Topilin, N.; Kul'chitskij, Yu.

    1997-01-01

    Describing of the auxiliary technology equipment for the submodule and module manipulations is presented. The results of the 0-module beam incoming control are given. The variations of the assembled module control measurements are described. The description of the construction for the 0-module transportation is presented

  2. Design of electronic measurement and quench detection equipment for the Current Lead Test facility Karlsruhe (CuLTKa)

    Energy Technology Data Exchange (ETDEWEB)

    Hollik, Markus, E-mail: markus.hollik@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Technical Physics (ITEP), Karlsruhe (Germany); Fietz, Walter H.; Fink, Stefan; Gehrlein, Mirko; Heller, Reinhard; Lange, Christian [Karlsruhe Institute of Technology (KIT), Institute for Technical Physics (ITEP), Karlsruhe (Germany); Möhring, Tobias [Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig (Germany)

    2013-10-15

    The Current Lead Test facility Karlsruhe (CuLTKa) is under construction at the Karlsruhe Institute of Technology (KIT) to perform acceptance tests of high temperature superconductor (HTS) current leads (CL). CuLTKa is in progress and present planning expects the completion in 2013. The data acquisition system is based on a modular design with electronic measurement and monitoring equipment covering a test voltage of 50 kV DC against ground. It provides plug-in units which enable temperature and voltage measurement at high voltage potential and in addition quench detection units which detect a loss of superconductivity reliably and quickly to avoid damage of the superconducting device under test. Prototype units for quench detection, temperature and voltage measurement have been successfully tested. Six temperature measurement units are already in use in the KIT test facility TOSKA and operated reliably during the acceptance tests of the HTS current leads for Wendelstein 7-X (W7-X) in 2011/2012. CuLTKa will be used first for 26 current leads which will be built in KIT for the fusion experiment JT-60SA. The present paper gives an overview of the design of the electronic measurement and quench detection equipment.

  3. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Radiological equipment is not purpose-built for each individual application. Thus, not only are acceptance criteria directly related to the design of equipment and the quality assurance exercised during its manufacture, but also the performance, safety and reliability of equipment must feature in the requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. Similarly the continuing reliability of equipment in service is directly related to the quality of maintenance services. This is determined largely by the manner in which such services are procured. In the UK this issue has been considered by one of four Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes the complementary duties of contractors and customers. The use in X-ray departments of the kind of manufacturing quality system that is used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure to patients. (author)

  4. Decant pump assembly and controls qualification testing - test report

    Energy Technology Data Exchange (ETDEWEB)

    Staehr, T.W., Westinghouse Hanford

    1996-05-02

    This report summarizes the results of the qualification testing of the supernate decant pump and controls system to be used for in-tank sludge washing in aging waste tank AZ-101. The test was successful and all components are qualified for installation and use in the tank.

  5. Experimental Study of the Power Profile Airfoil Equipped with Plasma Flow Control

    Science.gov (United States)

    Daniel, Libin; Jacob, Jamey

    2013-11-01

    This presentation discusses results from an experimental study of the power profile airfoil at low Reynolds number. The power profile airfoil was developed by AMO Smith and consists of a blunt trailing edge shape with two wall jets near the trailing edge. The replacement of streamlining with properly designed blowing is used to prevent flow separation and additionally offers potential applications as a powered high-lift system, propulsive system, or low inertia control device. The 2D wind-tunnel model consists of the 22.5% thick power profile airfoil equipped with a movable trailing edge plug to direct flow along the trailing edge streamline. Compressed air was passed into the model via a plenum with flow conditioning devices to create pressure backdrop to allow uniform blowing at the trailing edge. The effects of varying jet momentum coefficient and trailing edge positioning on the aerodynamic characteristics are observed with both wake surveys and PIV. The impact of plasma synthetic jet actuators (PSJA) placed along the trailing edge of the power profile airfoil is also discussed. PSJA operation is compared to the baseline power profile airfoil both alone and working with the blowing to provide additional control authority.

  6. Advantages of a program of quality control in the nuclear medicine equipment

    International Nuclear Information System (INIS)

    Trujillo Z, F.E.; Argumosa, E.; Herrera R, M.R.

    2007-01-01

    In Nuclear Medicine more 90% of the entirety of the carried out procedures its are with diagnostic ends where it is acquired one or several images. This makes indispensable to have an appropriate operation of the dedicated equipment to produce images and also of those non former images, as the activity caliper, to assure an appropriate quality diagnoses not from the images and the correct dose administration to the patient. In this work the main calibrations that should be carried out and an example of the program of quality control of a gamma camera mark Siemens and model E.CAM are presented. Considerations that should take as for the radiological protection are exposed. Comments on the parameters that correct the required calibrations and the images taken place by an operation or inadequate calibrations are included. In conclusion, the necessity of a program that it contains as minimum the quality control of the gamma cameras and of the activity caliper, having as main advantages a good image quality diagnoses and to minimize the dose imparted the patient are exposed. (Author)

  7. Measurement and control techniques for electric equipment development; Tecnicas de medicion y control para el desarrollo de equipos electricos

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    In broad outlines the measuring and control techniques that are used in the electric equipment development in the short circuit laboratories, are described. In this article the utilization criteria of the traditional and modern (analogical and digital) instruments are described as well as the tendency towards the system`s integration for the automation of the measurement and control processes. Also, mention is made of the systems currently being developed at the Instituto de Investigaciones Electricas (IIE) to be applied at the Short Circuit Laboratories of Comision Federal de Electricidad (CFE) and of the IIE. [Espanol] Se describen a grandes rasgos las tecnicas de medicion y control que se emplean para el desarrollo de equipos electricos en los laboratorios de corto circuito. En este articulo se describen los criterios de utilizacion de los instrumentos tradicionales y modernos (analogicos y digitales), asi como la tendencia hacia la integracion de sistemas para la automatizacion de los procesos de medicion y control. Tambien se mencionan los sistemas que actualmente se desarrollan en el Instituto de Investigaciones Electricas (IIE) para aplicarlos en los Laboratorios de Corto Circuito de la Comision Federal de Electricidad (CFE) y del Instituto.

  8. Development of the graphic design and control system based on a graphic simulator for the spent fuel dismantling equipment

    International Nuclear Information System (INIS)

    Lee, J. Y.; Kim, S. H.; Song, T. G.; Yoon, J. S.

    2000-06-01

    In this study, the graphic design system is developed for designing the spent fuel rod consolidation and the dismantling processes. This system is used throughout the design stages from the conceptual design to the motion analysis. Also, the real-time control system of the rod extracting equipment is developed. This system utilizes the graphic simulator which simulates the motion of the equipment in real time by synchronously connecting the control PC with the graphic server through the TCP/IP network. The developed system is expected to be used as an effective tool in designing the process equipment for the spent fuel management. And the real-time graphic control system can be effectively used to enhance the reliability and safety of the spent fuel handling process by providing the remote monitoring function of the process

  9. Equipment for testing a group of nuclear reactor fuel elements for damage to the cans

    International Nuclear Information System (INIS)

    Mohm, F.

    1977-01-01

    Equipment is described for use in sodium cooled nuclear reactors, with which the fuel elements consisting of bundles of fuel and fertile rods can be examined for damage to the cans. Fission poducts occurring in the liquid coolant act as indicators. The coolant is sucked via pipelines which penetrate into the elements into a collecting container, and a special pipeline is available for every element of a group, where the highest points of individual pipelines at different hydrostatic heads are taken to the collecting container. This permits the checking of one line at a time due to pressure changes. (UWI) [de

  10. An assessment of workplace programmes designed to control inhalation risks using respiratory protective equipment.

    Science.gov (United States)

    Bell, Nikki; Vaughan, Nicholas P; Morris, Len; Griffin, Peter

    2012-04-01

    Few studies have assessed respiratory protective equipment (RPE) failures at the organizational level despite evidence to suggest that compliance with good practice may be low. The aim of this study was to develop an understanding of what current RPE programmes look like across industry and how this compares with good practice. Twenty cross-industry site visits were conducted with companies that had RPE programmes in place. Visits involved management interviews to explore current RPE systems and procedures and the decision making underpinning these. Observations of RPE operatives were included followed by short interviews to discuss the behaviours observed. Post-site assessments jointly undertaken by an RPE scientist and psychologist produced ratings for each site on six critical aspects of RPE programmes (knowledge/awareness, selection, use, training/information, supervision, and storage/cleaning/maintenance). Overall ratings for theoretical competence (i.e. management knowledge of RPE) and practical control (i.e. actual RPE practice on the shop floor) were also given. Qualitative analysis was performed on all interview data. The performance of RPE programmes varied across industry. Fewer than half the companies visited were considered to have an acceptable level of theoretical competence and practical control. Four distinct groups emerged from the 20 sites studied, ranging from Learners (low theoretical competence and practical control--four sites), Developers (acceptable theoretical competence and low practical control--five sites), and Fortuitous (low theoretical competence and acceptable practical control--two sites), to Proficient (acceptable theoretical competence and practical control--nine sites). None of the companies visited were achieving optimal control through the use of RPE. Widespread inadequacies were found with programme implementation, particularly training, supervision, and maintenance. Our taxonomy based on the four groups (Learners, Developers

  11. Testing device for control rod drives

    International Nuclear Information System (INIS)

    Hayakawa, Toshifumi.

    1992-01-01

    A testing device for control rod drives comprises a logic measuring means for measuring an output signal from a control rod drive logic generation circuit, a control means for judging the operation state of a control rod and a man machine interface means for outputting the result of the judgement. A driving instruction outputted from the control rod operation device is always monitored by the control means, and if the operation instruction is stopped, a testing signal is outputted to the control rod control device to simulate a control rod operation. In this case, the output signal of the control rod drive logic generation circuit is held in a control rod drive memory means and intaken into a logic analysis means for measurement and an abnormality is judged by the control means. The stopping of the control rod drive instruction is monitored and the operation abnormality of the control rod is judged, to mitigate the burden of an operator. Further, the operation of the control rod drive logic generation circuit can be confirmed even during a nuclear plant operation by holding the control rod drive instruction thereby enabling to improve maintenance efficiency. (N.H.)

  12. The control, monitor, and alarm system for the ICT equipment of the ASTRI SST-2M telescope prototype for the Cherenkov Telescope Array

    Science.gov (United States)

    Gianotti, Fulvio; Fioretti, Valentina; Tanci, Claudio; Conforti, Vito; Tacchini, Alessandro; Leto, Giuseppe; Gallozzi, Stefano; Bulgarelli, Andrea; Trifoglio, Massimo; Malaguti, Giuseppe; Zoli, Andrea

    2014-07-01

    ASTRI is an Italian flagship project whose first goal is the realization of an end-to-end telescope prototype, named ASTRI SST-2M, for the Cherenkov Telescope Array (CTA). The prototype will be installed in Italy during Fall 2014. A second goal will be the realization of the ASTRI/CTA mini-array which will be composed of seven SST-2M telescopes placed at the CTA Southern Site. The Information and Communication Technology (ICT) equipment necessary to drive the infrastructure for the ASTRI SST-2M prototype is being designed as a complete and stand-alone computer center. The design goal is to obtain basic ICT equipment that might be scaled, with a low level of redundancy, for the ASTRI/CTA mini-array, taking into account the necessary control, monitor and alarm system requirements. The ICT equipment envisaged at the Serra La Nave observing station in Italy, where the ASTRI SST-2M telescope prototype will operate, includes computers, servers and workstations, network devices, an uninterruptable power supply system, and air conditioning systems. Suitable hardware and software tools will allow the parameters related to the behavior and health of each item of equipment to be controlled and monitored. This paper presents the proposed architecture and technical solutions that integrate the ICT equipment in the framework of the Observatory Control System package of the ASTRI/CTA Mini- Array Software System, MASS, to allow their local and remote control and monitoring. An end-toend test case using an Internet Protocol thermometer is reported in detail.

  13. 242A Distributed Control System Year 2000 Acceptance Test Report

    Energy Technology Data Exchange (ETDEWEB)

    TEATS, M.C.

    1999-08-31

    This report documents acceptance test results for the 242-A Evaporator distributive control system upgrade to D/3 version 9.0-2 for year 2000 compliance. This report documents the test results obtained by acceptance testing as directed by procedure HNF-2695. This verification procedure will document the initial testing and evaluation of the potential 242-A Distributed Control System (DCS) operating difficulties across the year 2000 boundary and the calendar adjustments needed for the leap year. Baseline system performance data will be recorded using current, as-is operating system software. Data will also be collected for operating system software that has been modified to correct year 2000 problems. This verification procedure is intended to be generic such that it may be performed on any D/3{trademark} (GSE Process Solutions, Inc.) distributed control system that runs with the VMSTM (Digital Equipment Corporation) operating system. This test may be run on simulation or production systems depending upon facility status. On production systems, DCS outages will occur nine times throughout performance of the test. These outages are expected to last about 10 minutes each.

  14. Application of a path sensitizing method on automated generation of test specifications for control software

    International Nuclear Information System (INIS)

    Morimoto, Yuuichi; Fukuda, Mitsuko

    1995-01-01

    An automated generation method for test specifications has been developed for sequential control software in plant control equipment. Sequential control software can be represented as sequential circuits. The control software implemented in a control equipment is designed from these circuit diagrams. In logic tests of VLSI's, path sensitizing methods are widely used to generate test specifications. But the method generates test specifications at a single time only, and can not be directly applied to sequential control software. The basic idea of the proposed method is as follows. Specifications of each logic operator in the diagrams are defined in the software design process. Therefore, test specifications of each operator in the control software can be determined from these specifications, and validity of software can be judged by inspecting all of the operators in the logic circuit diagrams. Candidates for sensitized paths, on which test data for each operator propagates, can be generated by the path sensitizing method. To confirm feasibility of the method, it was experimentally applied to control software in digital control equipment. The program could generate test specifications exactly, and feasibility of the method was confirmed. (orig.) (3 refs., 7 figs.)

  15. Ammunition Peculiar Equipment (APE) 1995, NIR Propellant Analyzer, to MIL-STD-398, Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance

    National Research Council Canada - National Science Library

    2003-01-01

    ... (SJMAC-DEM) to test the Ammunition Peculiar Equipment (APE) 1995 NIR Propellant Analyzer, to MIL-STD-398, "Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance...

  16. ENVIRONMENTAL TECHNOLOGY VERIFICATION COATINGS AND COATING EQUIPMENT PROGRAM (ETV CCEP), FINAL TECHNOLOGY APPLICATIONS GROUP TAGNITE--TESTING AND QUALITY ASSURANCE PLAN (T/QAP)

    Science.gov (United States)

    The overall objective of the Environmental Testing and Verification Coatings and Coating Equipment Program is to verify pollution prevention and performance characteristics of coating technologies and make the results of the testing available to prospective coating technology use...

  17. Tank monitor and control system (TMACS) revision 11 acceptance test procedure

    International Nuclear Information System (INIS)

    HOLM, M.J.

    1999-01-01

    The purpose of this document is to describe tests performed to validate Revision 11 of the Tank Monitor and Control System (TMACS) and verify that the software functions as intended by design. This document is intended to test the software portion of TMACS. The tests will be performed on the development system. The software to be tested is the TMACS knowledge bases (KB) and the I/O driver/services. The development system will not be talking to field equipment; instead, the field equipment is simulated using emulators or multiplexers in the lab

  18. Design Study and Optimization of Irradiation Facilities for Detector and Accelerator Equipment Testing in the SPS North Area at CERN

    CERN Document Server

    AUTHOR|(CDS)2079748; Stekl, Ivan

    Due to increasing performance of LHC during the last years, the strong need of new detector and electronic equipment test areas at CERN appeared from user communities. This thesis reports on two test facilities: GIF++ and H4IRRAD. GIF++, an upgrade of GIF facility, is a combined high-intensity gamma and particle beam irradiation facility for testing detectors for LHC. It combines a high-rate 137Cs source, providing photons with energy of 662 keV, together with the high-energy secondary particle beam from SPS. H4IRRAD is a new mixed-field irradiation area, designed for testing LHC electronic equipment for radiation damage effects. In particular, large volume assemblies such as full electronic racks of high current power converters can be tested. The area uses alternatively an attenuated primary 400 GeV/c proton beam from SPS, or a secondary, mainly proton, beam of 280 GeV/c directed towards a copper target. Different shielding layers are used to reproduce a radiation field similar to the LHC “tunnel” and �...

  19. A Discussion of Procedures and Equipment for the Comprehensive Test Ban Treaty On-Site Inspection Environmental Sampling and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wogman, Ned A.; Milbrath, Brian D.; Payne, Rosara F.; Seifert, Carolyn E.; Friese, Judah I.; Miley, Harry S.; Bowyer, Ted W.; Hanlen, Richard C.; Onishi, Yasuo; Hayes, James C.; Wigmosta, Mark S.

    2011-02-01

    This paper is intended to serve as a scientific basis to start discussions of the available environmental sampling techniques and equipment that have been used in the past that could be considered for use within the context of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) on-site inspections (OSI). This work contains information on the techniques, equipment, costs, and some operational procedures associated with environmental sampling that have actually been used in the past by the United States for the detection of nuclear explosions. This paper also includes a discussion of issues, recommendations, and questions needing further study within the context of the sampling and analysis of aquatic materials, atmospheric gases, atmospheric particulates, vegetation, sediments and soils, fauna, and drill-back materials.

  20. Equipment for the forecast and operating control of the natural catastrophes dynamics

    International Nuclear Information System (INIS)

    Kazansev, S.I.; Koblik, Yu.N.; Yuldashev, B.S.; Kuzhevskij, B.M.; Nechaev, O.Yu.

    2004-01-01

    Full text: Necessity of the solution of forecast the natural catastrophes such as: earthquakes, the volcanic activity stirring up, origin of the mud flows, landslides, sudden moving of pulsating glaciers, awesome atmospheric phenomena is realized a long time ago. However numerous attempts to find the solution yet have not yielded desirable result. Representative example to this is the absence to the present time of the physically justified earthquake forecast. Perennial observations of the Earth neutron field with the help of designed by us equipment, both in seismically active regions (Tien - Shan, Pamir, Kamchatka) and in seismically quiet regions (Moscow and Tver regions) demonstrated, that the variations of neutron radiation near the earth crust allow us to elaborate near-term (tens hours, some day) the earthquakes forecast. These researches have also revealed correlation between variations of neutron and magnetic fields of the Earth. In this connection it is represented, that a hardware complex permitting simultaneously to watch variations of a neutron radiation near the earth crust and variation of a magnetic field of the Earth will appear sufficient for the purposes of a short forecast of natural debacles and, besides will allow us to execute the operating control of temporary development of already happened event

  1. Equipment for the forecast and operating control of the natural catastrophes dynamics

    International Nuclear Information System (INIS)

    Kazantsev, S.I.; Koblik, Yu.N.; Yuldashev, B.S.; Kuzhevskij, B.M.; Nechaev, O.Yu.

    2004-01-01

    Necessity of the solution of forecast the natural catastrophes such as: earthquakes, the volcanic activity stirring up, origin of the mud flows, landslides, sudden moving of pulsating glaciers, awesome atmospheric phenomena is realized a long time ago. However numerous attempts to find the solution yet have not yielded desirable result. Representative example to this is the absence to the present time of the physically justified earthquake forecast. Perennial observations of the Earth neutron field with the help of designed by us equipment, both in seismically active regions (Tien - Shan, Pamir, Kamchatka) and in seismically quiet regions (Moscow and Tver regions) demonstrated, that the variations of neutron radiation near the earth crust allow us to elaborate near-term (tens hours, some day) the earthquakes forecast. These researches have also revealed correlation between variations of neutron and magnetic fields of the Earth. In this connection it is represented, that a hardware complex permitting simultaneously to watch variations of a neutron radiation near the earth crust and variation of a magnetic field of the Earth will appear sufficient for the purposes of a short forecast of natural debacles and, besides will allow us to execute the operating control of temporary development of already happened event. (author)

  2. Mounted Smartphones as Measurement and Control Platforms for Motor-Based Laboratory Test-Beds

    OpenAIRE

    Jared A. Frank; Anthony Brill; Vikram Kapila

    2016-01-01

    Laboratory education in science and engineering often entails the use of test-beds equipped with costly peripherals for sensing, acquisition, storage, processing, and control of physical behavior. However, costly peripherals are no longer necessary to obtain precise measurements and achieve stable feedback control of test-beds. With smartphones performing diverse sensing and processing tasks, this study examines the feasibility of mounting smartphones directly to test-beds to exploit their em...

  3. Testing a Constrained MPC Controller in a Process Control Laboratory

    Science.gov (United States)

    Ricardez-Sandoval, Luis A.; Blankespoor, Wesley; Budman, Hector M.

    2010-01-01

    This paper describes an experiment performed by the fourth year chemical engineering students in the process control laboratory at the University of Waterloo. The objective of this experiment is to test the capabilities of a constrained Model Predictive Controller (MPC) to control the operation of a Double Pipe Heat Exchanger (DPHE) in real time.…

  4. Train-to-train impact test of crash energy management passenger rail equipment.

    Science.gov (United States)

    2007-02-01

    On March 23, 2006, a full-scale test was conducted on a passenger rail train retrofitted with newly developed cab and coach car crush zone designs. This test was conducted as part of a larger testing program to establish the degree of enhanced perfor...

  5. Train-to-Train Impact Test of Crash-Energy Management Passenger Rail Equipment: Structural Results

    Science.gov (United States)

    2006-01-01

    On March 23, 2006, a full-scale test was conducted on a : passenger rail train retrofitted with newly developed cab end : and non-cab end crush zone designs. This test was conducted : as part of a larger testing program to establish the degree of : e...

  6. FEATURES OF RESOURCE TESTING OF THE HYDRAULIC BRAKE DRIVE ELEMENTS OF VEHICLES EQUIPPED WITH ABS

    Directory of Open Access Journals (Sweden)

    A. Revin

    2011-01-01

    Full Text Available The analysis of the resource testing facilities and methods of automobile brake cylinders in terms of ABS working process adequacy is carried out. A testing stand construction and a method of carrying out the resource testing of hydraulic drive elements of the automobile automated braking sys-tem is offered.

  7. Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals

    Directory of Open Access Journals (Sweden)

    Noel S. Ha

    2017-11-01

    Full Text Available Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET or single photon emission tomography (SPECT scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers must undergo quality control (QC testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a

  8. Procuring, maintaining and using equipment: the key issues in controlling exposure to patients

    International Nuclear Information System (INIS)

    Hendra, I.R.F.

    1989-01-01

    Not only are acceptance criteria directly related to the design of medical x-ray equipment and quality assurance exercised during its manufacture, but also its performance, safety and reliability must feature in requirements for procuring new equipment. In the UK this issue is dealt with under the Department of Health and Social Security Manufacturer Registration Scheme for Medical Equipment in its application to radiological equipment. In the UK quality of maintenance services has been considered by one of our Working Parties commissioned by the South-East Thames Regional Health Authority who are the ''Centre of Responsibility'' for diagnostic imaging equipment in the National Health Service. The report prepared from the first phase of activity of this working group describes features of a procurement specification for maintenance services and prescribes complementary duties of contractors and customers. Radiograph reject analysis has indicated human error outweighs unsatisfactory equipment performance as the reason for rejecting poor radiographs. The use in X-ray departments of the kind of manufacturing quality system used by most reputable equipment manufacturers has the potential for a dramatic reduction in exposure. (author)

  9. Balanced testing scorecard: um modelo para avaliação e melhoria de desempenho de equipes de testes de software

    OpenAIRE

    Oliveira Nóbrega, Rafael

    2008-01-01

    A realização de testes é uma atividade vital para o desenvolvimento de software com qualidade. Muitas empresas têm investido alto visando a melhoria do desempenho das equipes de testes. Para ajudar na satisfação deste objetivo, os modelos de maturidade de testes são ferramentas bastante utilizadas atualmente. Porém, segundo James Bach (1994), estes modelos não são populares entre empresas desenvolvedoras de software altamente competitivas e inovadoras porque, entre outros mo...

  10. Equipment for long-term testing of material creep in liquid sodium

    International Nuclear Information System (INIS)

    Dufek, F.; Walder, V.; Cech, V.; Winkler, P.

    1980-01-01

    A sodium test plant is described and the methods are shown of securing the desired test specifications. The facility is used for the long-term testing of nonsteady material creep under the action of temperature and mechanical stress due to the static or pulsed overpressure of inert gas inside a tube specimen and a simultaneous effect of sodium flow on the outside wall. The test results are to be used for comparing Czechoslovak-made steels with foreign materials and also for testing the degradation effects of the above phenomena on the standardized long-term properties in inert and steady state conditions. (B.S.)

  11. B Complex Test Control Center (TCC) #4210

    Data.gov (United States)

    Federal Laboratory Consortium — The TCC is a dual control room facility for the B-1 and B-2 Test Positions on the B-Stand. The TCC houses continually-updated, state-of-the-art Data Acquisition and...

  12. The Ural Electrochemical Integrated Plant Process for Managing Equipment Intended for Nuclear Material Protection, Control and Accounting System Upgrades

    International Nuclear Information System (INIS)

    Yuldashev, Rashid; Nosov, Andrei; Carroll, Michael F.; Garrett, Albert G.; Dabbs, Richard D.; Ku, Esther M.

    2008-01-01

    Since 1996, the Ural Electrochemical Integrated Plant (UEIP) located in the town of Novouralsk, Russia, (previously known as Sverdlovsk-44) and the United States Department of Energy (U.S. DOE) have been cooperating under the Nuclear Material Protection, Control and Accounting (MPC and A) Program. Because UEIP is involved in the processing of highly enriched uranium (HEU) into low enriched uranium (LEU), and there are highly enriched nuclear materials on its territory, the main goal of the MPC and A cooperation is to upgrade those systems that ensure secure storage, processing and transportation of nuclear materials at the plant. UEIP has completed key upgrades (equipment procurement and installation) aimed at improving MPC and A systems through significant investments made by both the U.S. DOE and UEIP. These joint cooperative efforts resulted in bringing MPC and A systems into compliance with current regulations, which led to nuclear material (NM) theft risk reduction and prevention from other unlawful actions with respect to them. Upon the U.S. MPC and A project team's suggestion, UEIP has developed an equipment inventory control process to track all the property provided through the MPC and A Program. The UEIP process and system for managing equipment provides many benefits including: greater ease and efficiency in determining the quantities, location, maintenance and repair schedule for equipment; greater assurance that MPC and A equipment is in continued satisfactory operation; and improved control in the development of a site sustainability program. While emphasizing UEIP's equipment inventory control processes, this paper will present process requirements and a methodology that may have practical and helpful applications at other sites.

  13. Weapon Simulator Test Methodology Investigation: Comparison of Live Fire and Weapon Simulator Test Methodologies and the Effects of Clothing and Individual Equipment on Marksmanship

    Science.gov (United States)

    2016-09-15

    SHOOTING PERFORMANCE BASE LINES REACTION TIME DATA COLLECTION CIE(CLOTHING AND INDIVIDUAL EQUIPMENT) U.S. Army Natick Soldier Research...Ranger Regiment and two Aberdeen Test Center (ATC) Contractors as Representative Soldiers ( CARS ) served as TPs in the evaluation, which took place at...added. This target required each participant to shoot two series of five shots in the following conditions (this target mimicked one of the

  14. 49 CFR 236.566 - Locomotive of each train operating in train stop, train control or cab signal territory; equipped.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locomotive of each train operating in train stop, train control or cab signal territory; equipped. 236.566 Section 236.566 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF...

  15. CHARACTERIZATION OF OZONE EMISSIONS FROM AIR CLEANERS EQUIPPED WITH OZONE GENERATORS AND SENSOR AND FEEDBACK CONTROL CIRCUITRY

    Science.gov (United States)

    The paper give results of a characterization of ozone emissions from air cleaners equipped with ozone generators and sensor and feedback control circuitry. Ozone emission rates of several consumer appliances, marketed as indoor air treatment or air purification systems, were det...

  16. Effectiveness of personal protective equipment: Relevance of dermal and inhalation exposure to chlorpyrifos among pest control operators

    NARCIS (Netherlands)

    Jagt, K. van der; Tielemans, E.; Links, I.; Brouwer, D.; Hemmen, J. van

    2004-01-01

    This study assessed the effectiveness of a custom fit personal protective equipment (PPE) program aimed at reducing occupational exposure to pesticides. The intervention study was carried out on 15 pest control operators (PCOs) during mixing/loading and application of chlorpyrifos. Each worker was

  17. Train-to-Train Impact Test of Crash-Energy Management Passenger Rail Equipment: Occupant Experiments

    Science.gov (United States)

    2006-11-06

    As part of an ongoing passenger rail crashworthiness effort, : a full-scale impact test of a train with crash energy management : (CEM) passenger cars was conducted on March 23, 2006. In : this test, a train made up of a CEM cab car, four CEM coach :...

  18. Test methodology for elemental sulfur resistant advanced materials for oil and gas field equipment

    Energy Technology Data Exchange (ETDEWEB)

    Steinbeck, G. [Verein Deutscher Eisenhuettenleute, Duesseldorf (Germany); Bruckhoff, W. [BEB Erdgas und Erdoel GmbH, Hannover (Germany); Koehler, M. [Krupp-VDM AG, Werdohl (Germany); Schlerkmann, H. [Mannesmann Forschungsinstitut, Duisburg (Germany); Schmitt, G. [Iserlohn Polytechnic (Germany). Lab. for Corrosion Protection

    1995-10-01

    The great variety of methodologies for testing the performance of advanced materials for resistance to elemental sulfur in oil and gas industry prompted the Technical Committee for Corrosion of the German Iron and Steel Institute (VDEh) to define recommended test procedures. These procedures have already found wide acceptance in the German materials and oil and gas industry.

  19. Features of the national export control on international transfers of nuclear materials, equipment and technologies in Ukraine

    Directory of Open Access Journals (Sweden)

    I. E. Anokhin

    2015-04-01

    Full Text Available National export control system of Ukraine is analyzed in the context of the current state of solving problems related to non-proliferation of weapons of mass destruction. The legal framework and structure of the system, the foundations of the organization and implementation of national export control in Ukraine are described. The features of the national control lists of equipment, materials and dual-use technologies in connection with the prospect of transition to a new single control list, based on the structure of the European Union control list, are considered.

  20. Failure analysis on false call probe pins of microprocessor test equipment

    Science.gov (United States)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    A study has been conducted to investigate failure analysis on probe pins of test modules for microprocessor. The `health condition' of the probe pin is determined by the resistance value. A test module of 5V power supplied from Arduino UNO with "Four-wire Ohm measurement" method is implemented in this study to measure the resistance of the probe pins of a microprocessor. The probe pins from a scrapped computer motherboard is used as the test sample in this study. The functionality of the test module was validated with the pre-measurement experiment via VEE Pro software. Lastly, the experimental work have demonstrated that the implemented test module have the capability to identify the probe pin's `health condition' based on the measured resistance value.

  1. Advanced Control Test Operation (ACTO) facility

    International Nuclear Information System (INIS)

    Ball, S.J.

    1987-01-01

    The Advanced Control Test Operation (ACTO) project, sponsored by the US Department of Energy (DOE), is being developed to enable the latest modern technology, automation, and advanced control methods to be incorporated into nuclear power plants. The facility is proposed as a national multi-user center for advanced control development and testing to be completed in 1991. The facility will support a wide variety of reactor concepts, and will be used by researchers from Oak Ridge National Laboratory (ORNL), plus scientists and engineers from industry, other national laboratories, universities, and utilities. ACTO will also include telecommunication facilities for remote users

  2. The Design and Realization of Multimedia Textbook The Equipment of Ship’s Command and Control(C2) System

    Science.gov (United States)

    Zhang, Hao; Yang, Hui

    2017-10-01

    Based on the powerful multimedia interactive integration platform of Director, the paper designs to make a multimedia textbook The Equipment of Ship’s Command and Control(C2) System with reference to the characteristics of the equipment, while making use of various image and sound editing software like Photoshop and Video Studio who are rich in functions. It attempts to solve problems in the teaching of the course, such as unitary teaching mode, outmoded course content, unsatisfactory teaching result, the lack of fitted textbook, etc.

  3. Peptide-equipped tobacco mosaic virus templates for selective and controllable biomineral deposition

    Directory of Open Access Journals (Sweden)

    Klara Altintoprak

    2015-06-01

    Full Text Available The coating of regular-shaped, readily available nanorod biotemplates with inorganic compounds has attracted increasing interest during recent years. The goal is an effective, bioinspired fabrication of fiber-reinforced composites and robust, miniaturized technical devices. Major challenges in the synthesis of applicable mineralized nanorods lie in selectivity and adjustability of the inorganic material deposited on the biological, rod-shaped backbones, with respect to thickness and surface profile of the resulting coating, as well as the avoidance of aggregation into extended superstructures. Nanotubular tobacco mosaic virus (TMV templates have proved particularly suitable towards this goal: Their multivalent protein coating can be modified by high-surface-density conjugation of peptides, inducing and governing silica deposition from precursor solutions in vitro. In this study, TMV has been equipped with mineralization-directing peptides designed to yield silica coatings in a reliable and predictable manner via precipitation from tetraethoxysilane (TEOS precursors. Three peptide groups were compared regarding their influence on silica polymerization: (i two peptide variants with alternating basic and acidic residues, i.e. lysine–aspartic acid (KDx motifs expected to act as charge-relay systems promoting TEOS hydrolysis and silica polymerization; (ii a tetrahistidine-exposing polypeptide (CA4H4 known to induce silicification due to the positive charge of its clustered imidazole side chains; and (iii two peptides with high ZnO binding affinity. Differential effects on the mineralization of the TMV surface were demonstrated, where a (KDx charge-relay peptide (designed in this study led to the most reproducible and selective silica deposition. A homogenous coating of the biotemplate and tight control of shell thickness were achieved.

  4. Revision to dedicated short range communication roadside equipment specification - RSU 4.1.Bench Test Plan.

    Science.gov (United States)

    2017-04-28

    The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...

  5. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Science.gov (United States)

    2010-01-01

    ... of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY... Unvented Home Heating Equipment 1. Testing conditions. 1.1Installation. 1.1.1Electric heater. Install... higher heating value within ±5 percent of 1,025 Btu's per standard cubic foot. Determine the higher...

  6. The Design and Implementation of the Remote Centralized-Monitoring System of Well-Control Equipment Based on RFID Technique

    OpenAIRE

    Luo Bin; Liu Jiarui; Li Junlan; Liang Haibo

    2017-01-01

    At present, in domestic for the management of well control equipment continue to the traditional way of nameplates identifies and paper-based registration, there are many issues like the separation of data information of device, easy lose, difficult query, confused management and many other problems, which will make the problem device into the well field, and then resulting in well control runaway drilling accident. To solve the above problems, this paper put forward to the integrated remote ...

  7. Main trends in steam generator monitoring using the equipment of a power unit technological process on-line control system

    International Nuclear Information System (INIS)

    Khutorestkij, G.M.; Vatan'yan, A.G.; Kotova, I.P.; Sivkov, A.P.

    1989-01-01

    The possibility to use signals of technological process control system equipment and data provided by conventional means of parameter on-line and technological control for functional diagnostics of turbine generators in the process of operation is analyzed. Four groups of parameters (power, thermal, mechanical and process) which should be taken into account when selecting algorithms and determining the order of various defect diagnostics are separated. 4 refs.; 2 figs.; 1 tab

  8. Design of experiments and equipment to test the ballooning characteristics of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Forrest, C.F.; Stern, F.; Hart, R.G.

    1992-01-01

    Experiments have been planned and an apparatus has been designed to enable creep testing of end-of-life pressure tube specimens in a LOCA environment. Effects that could be studied include: annealing of irradiation damage during transient heating; effects of hydride blisters on pressure tube ballooning strains; and, effects of uniformly-distributed hydrogen content on pressure tube ballooning strains. The proposed experimental program will consist of separate effects creep tests on pressure tube sections under transient heating conditions

  9. The heater system monitoring and control of the fuelling machines test rig fluid

    International Nuclear Information System (INIS)

    Iorga, C.; Iorga, H.

    2016-01-01

    The thermo-mechanical hot loop (HL) of the testing rig for the fuelling machines (F/Ms) represents a set of facilities and equipment that perform the pressure, temperature and flow thermo-hydraulic parameters similar to those from the fuel channel for CANDU 600 reactor types. The 2.1 MW electric heater (EH), part of the HL, working under the conditions of a pressure vessel (110 bars) and provides an average temperature of 300°C of the working agent. The monitoring equipment implemented aims to simultaneously control the temperature for each of the 12 modules that compose the EH, without influencing the work logic of the display/recording and protecting existing equipment. This paper presents the structure of the monitoring equipment and its performance obtained after performing the functional tests. (authors)

  10. Study of the test method for prediction of air conditioning equipment seasonal performance

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, S.B.

    1980-05-01

    The test procedure, Method of Testing, Rating and Estimating the Seasonal Performance of Central Air-Conditioners and Heat Pumps Operating in the Cooling Mode, has been analyzed. The analysis of the test procedure incorporated two main functions: (1) to determine the validity of the test procedure; and (2) to determine if there are other alternate methods of obtaining the same results with less testing burden. Data were collected from industry and analyzed for any significant trends. Certain conclusions are drawn about the energy efficiency ratios, degradation coefficients and seasonal energy efficiency ratios. An error analysis was performed on the test procedure to determine the approximate amount of error when using this procedure. A semi-empirical model assuming a first order system response was developed to determine the factors that affect the part-load and cooling-load factors. The corresponding transient characteristics are then determined in terms of a single time constant. A thermostat demand cycle is used to determine the relationship between on-time and cycle-time. Recommendations are made regarding an alternate method being used to determine the seasonal energy efficiency ratio.

  11. Manual on quality assurance for installation and commissioning of instrumentation, control and electrical equipment in nuclear power plants

    International Nuclear Information System (INIS)

    1989-01-01

    The present Manual on Quality Assurance (QA) for Installation and Commissioning of Instrumentation, Control and Electrical (ICE) Equipment of Nuclear Power Plants contains supporting material and illustrative examples for implementing basic requirements of the quality assurance programme in procurement, receiving, installation and commissioning of this equipment. The Manual on Quality Assurance for Installation and Commissioning of ICE Equipment is designed to supplement and be consistent with the Guidebook as well as with the IAEA Code and Safety Guides on Quality Assurance. It is intended for the use of managerial staff and QA personnel of nuclear power plant owners or the organizations respectively responsible for the legal, technical, administrative and financial aspects of a nuclear power plant. The information provided in the Manual will also be useful to the inspection staff of the regulatory organization in the planning and performance of regulatory inspections at nuclear power plants

  12. Airside HVAC BESTEST. Adaptation of ASHRAE RP 865 Airside HVAC Equipment Modeling Test Cases for ASHRAE Standard 140. Volume 1, Cases AE101-AE445

    Energy Technology Data Exchange (ETDEWEB)

    Neymark, J. [J. Neymark & Associates, Golden, CO (United States); Kennedy, M. [Mike D. Kennedy, Inc., Townsend, WA (United States); Judkoff, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gall, J. [AAON, Inc., Tulsa, OK (United States); Knebel, D. [AAON, Inc., Tulsa, OK (United States); Henninger, R. [GARD Analytics, Inc., Arlington Heights, IL (United States); Witte, M. [GARD Analytics, Inc., Arlington Heights, IL (United States); Hong, T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McDowell, T. [Thermal Energy System Specialists, Madison, WI (United States); Yan, D. [Tsinghua Univ., Beijing (China); Zhou, X. [Tsinghua Univ., Beijing (China)

    2016-03-01

    This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.

  13. Development of equipment for migration control of radioactive cesium absorbed in suspended solid in the river water

    International Nuclear Information System (INIS)

    Ohyama, Takuya; Ishikawa, Hiroyasu

    2015-01-01

    To prevent inflow of radiocesium with suspended solids (SS) into farmland and increase in dose rate of the river bank in the midstream and downstream, it is important to reduce SS in the river water; therefore we newly developed the test equipment using non-woven fabrics as a trapping material to capture and reduce the SS in running small river water. Authors installed this equipment into the small river which is located in mountainous area surrounded by forests where radionuclides released from the Fukushima Daiichi Nuclear Power Plant were deposited. Two turbidity gauges are installed in inflow and outflow point of this equipment and the turbidity has been continuously measured. From the result of a comparison of turbidity between inflow point and outflow point, a turbidity of inflow point is always higher than outflow point during ordinary water-level; this equipment can capture and reduce the SS in the river water. Through the analysis of particle size distribution, identification of minerals and measurement of concentration of radioactive Cs of the captured SS in the non-woven fabric should be carried out, to clarify the effectiveness of this equipment and non-woven fabrics for reducing the radioactive Cs in small rivers in the future. (author)

  14. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

  15. USE OF-EPR-DL FIELD TEST EQUIPMENT FOR DETECTION OF SIGMA PHASE

    Directory of Open Access Journals (Sweden)

    Abraão Danilo Gomes Barreto

    2014-06-01

    Full Text Available This work has objective to correlate the intergranular corrosion susceptibility test named EPR-DL (Electrochemical Potentiokinetic Reactivation of Double Loop with the sigma phase formation and other phases. It has been used samples from a UNS S32760 steel pipe for conducting various aging heat treatments. Held isothermal heat treatment at 850°C for 1 min, 10 min, 30 min, 1 h, 1h30min and 10 h. Each heat treated sample and as received were tested using the electrochemical polarization reactivation of double loop technique (EPR-DL. It was possible the detection of deleterious phases with DL-EPR portable cell. The EPR-DL test of some samples showed a second peak of reactivation in which the results showed that this peak might be associated with ferrite or be related to the presence of chi phase

  16. Portable equipment for simultaneous assays of psychomotor vigilance test and pupillometry

    OpenAIRE

    Souza, John Kennedy Schettino De; Ginani, Giuliano Emerenciano [UNIFESP; Pompéia, Sabine [UNIFESP; Baron, Jerome; Tierra-criollo, Carlos Julio

    2013-01-01

    Neste artigo é descrito um sistema com potencial para identificar a privação do sono, que, com base no levantamento bibliográfico realizado, ainda não foi abordado na literatura. Este sistema integra simultaneamente duas metodologias, o teste de vigilância psicomotora (Psychomotor vigilance test, PVT) e a pupilometria, que se destacam no estudo da privação do sono. Entretanto, para atender às peculiaridades destas metodologias, permitindo que coexistam em um único sistema, algumas adaptações ...

  17. 78 FR 64295 - Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment

    Science.gov (United States)

    2013-10-28

    ... Reduction Act D. Review Under the National Environmental Policy Act E. Review Under Executive Order 13132 F... procedure to make such representations. However, DOE has not considered the energy usage of these types of..., as well as translucent fiberglass and multicell plastic panels, which cannot be tested with a...

  18. 75 FR 71596 - Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures for...

    Science.gov (United States)

    2010-11-24

    ... rulemaking because the provision within EISA which stipulates that off mode and standby mode energy usage... than night curtains made of plastic, linoleum, or other non- reflective materials. In addition, each... proposes a 6-hour test period to approximate the typical usage of a night curtain. In studies analyzing the...

  19. 14 CFR 91.411 - Altimeter system and altitude reporting equipment tests and inspections.

    Science.gov (United States)

    2010-01-01

    ... RULES Maintenance, Preventive Maintenance, and Alterations § 91.411 Altimeter system and altitude...), appendix E, of part 43 of this chapter; and (3) Following installation or maintenance on the automatic... airframe rating appropriate to the airplane, or helicopter, to be tested; or (3) A certificated mechanic...

  20. 30 CFR 7.103 - Safety system control test.

    Science.gov (United States)

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Diesel Power Packages Intended for Use in Areas of Underground Coal Mines Where Permissible Electric Equipment is Required § 7.103 Safety system...

  1. 40 CFR Appendix D to Subpart S of... - Steady-State Short Test Equipment

    Science.gov (United States)

    2010-07-01

    ... Appendix D to Subpart S of Part 51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS REQUIREMENTS FOR PREPARATION, ADOPTION, AND SUBMITTAL OF IMPLEMENTATION PLANS Inspection..., a flexible sample line, a water removal system, particulate trap, sample pump, flow control...

  2. 76 FR 18428 - Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures for...

    Science.gov (United States)

    2011-04-04

    ... compressor rack. Both of these remote refrigeration systems contain compressors and condensers that are in a... compressor and condenser energy consumption are excluded because ice maker manufacturers do not have control... designed to be used with remote compressor rack systems. Therefore, DOE proposes that all remote condensing...

  3. Development and Testing of an UltraBattery-Equipped Honda Civic Hybrid

    Energy Technology Data Exchange (ETDEWEB)

    Sally (Xiaolei) Sun; Tyler Gray; Pattie Hovorka; Jeffrey Wishart; Donald Karner; James Francfort

    2012-08-01

    The UltraBattery Retrofit Project DP1.8 and Carbon Enriched Project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy and the Advanced Lead Acid Battery Consortium (ALABC), are established to demonstrate the suitability of advanced lead battery technology in hybrid electrical vehicles (HEVs). A profile, termed the “Simulated Honda Civic HEV Profile” (SHCHEVP) has been developed in Project DP1.8 in order to provide reproducible laboratory evaluations of different battery types under real-world HEV conditions. The cycle is based on the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles and simulates operation of a battery pack in a Honda Civic HEV. One pass through the SHCHEVP takes 2,140 seconds and simulates 17.7 miles of driving. A complete nickel metal hydride (NiMH) battery pack was removed from a Honda Civic HEV and operated under SHCHEVP to validate the profile. The voltage behavior and energy balance of the battery during this operation was virtually the same as that displayed by the battery when in the Honda Civic operating on the dynamometer under the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles, thus confirming the efficacy of the simulated profile. An important objective of the project has been to benchmark the performance of the UltraBatteries manufactured by both Furukawa Battery Co., Ltd., Japan (Furakawa) and East Penn Manufacturing Co., Inc. (East Penn). Accordingly, UltraBattery packs from both Furakawa and East Penn have been characterized under a range of conditions. Resistance measurements and capacity tests at various rates show that both battery types are very similar in performance. Both technologies, as well as a standard lead-acid module (included for baseline data), were evaluated under a simple HEV screening test. Both Furakawa and East Penn UltraBattery packs operated for over 32,000 HEV cycles, with minimal loss in performance; whereas the

  4. Storm wave buoy equipped with micromechanical inertial unit: Results of development and testing

    Science.gov (United States)

    Gryazin, D. G.; Staroselcev, L. P.; Belova, O. O.; Gleb, K. A.

    2017-07-01

    The article describes the results of developing a wave buoy to measure the statistical characteristics of waves and the characteristics of directional spectra of three-dimensional waves. The device is designed for long-term measurements lasting up to a season, which can help solve problems in forecasting waves and preventing emergencies from wave impact on offshore platforms, hydraulic structures, and other marine facilities. The measuring unit involves triads of micromechanical gyroscopes, accelerometers, and a three-component magnetometer. A description of the device, results of laboratory research of its characteristics, and bench and full-scale tests are offered. It is noted that to assess the performance characteristics, comparative tests of the Storm wave buoy were conducted with a standard string wave probe installed on an offshore platform. It is shown that the characteristics and capabilities of the wave buoy make it possible to oust foreign devices from the domestic market.

  5. Mirror fusion test facility cryogenic system - performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1988-01-01

    The cryogenic system for the MFTF is a helium refrigeration system that proved to be successful and cost effective. All operating objectives were met while remaining within a few percent of the initial cost and schedule plans. The management approach used at MFTF is assessed. Manpower levels, extent and type of industrial participation, and subcontractor specifications and interactions are reviewed along with highlights of system testing, documentation, and operation

  6. Instantaneous response spectrum in seismic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Morrone, A.

    1977-01-01

    This paper presents the concept of instantaneous response spectrum (IRS) as the response of single degree of freedom oscillators at a particular time. It demonstrates that a shake table random motion whose standard TRS envelops the RRS does not necessarily satisfy the enveloping requirement instantaneously. That is, any one (or more) instantaneous required response spectrum (IRRS) is not enveloped by any instantaneous test response spectrum (ITRS). Response spectra from different time histories, including single frequency sine beat motion used in resonance testing, are compared for enveloping with maximum response and with the actual response at particular times. These comparisons are given for the enveloping of RRS and IRRS derived with a time history response calculated at a particular building elevation of a nuclear power plant. For the test motion, several of the most severe ITRS derived with a modified EL Centro motion and with a sine beat motion with ten cycles per beat were used. It is shown that although the TRS with the modified EL Centro motion enveloped the given RRS, the selected modified EL Centro ITRS did not envelop the corresponding IRRS. With the sine beat motion, even though the TRS did not fully envelop the given RRS, the resulting sine beat ITRS did not require a larger factor for full IRRS enveloping than those of the modified EL Centro motion

  7. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  8. Upgrading of seismic capacity of WWER equipment including reactor control rods and distribution systems

    International Nuclear Information System (INIS)

    Kostarev, V.

    1993-01-01

    This paper concerns the experience of CKTI VIBROSEISM firm (CVS) in seismic capacity upgrading of the WWER equipment and pipings. During the last 15 years CVS has accumulated a lot of experimental and analysis results on many of WWER units 'in former Soviet Union. That might be very useful in seismic protecting of East European Nuclear Power Plants. (author)

  9. The Potential of Computer Controlled Optimizing Equipment in the Wooden Furniture Industry

    Science.gov (United States)

    R. Edward Thomas; Urs Buehlmann; Urs Buehlmann

    2003-01-01

    The goal of the wooden furniture industry is to convert lumber into parts by using the most efficient and cost effective processing methods. The key steps in processing lumber arc removing the regions that contain unacceptable defects or character marks and cutting the remaining areas to the widths and lengths of needed parts. Such equipment has been used in furniture...

  10. Simulation and control of a HD diesel engine equipped with new EGR technology

    NARCIS (Netherlands)

    Dekker, H.J.; Sturm, W.L.

    1996-01-01

    A dynamic model of a Heavy Duty (HD) turbocharged and aftercooled diesel engine was developed. The engine was equipped with high pressure diesel injection, a Variable Geometry Turbine (VGT) and an Exhaust Gas Recirculation (EGR) system. This engine was targeted at meeting EURO4 emission

  11. Spaceport Command and Control System Automation Testing

    Science.gov (United States)

    Plano, Tom

    2017-01-01

    The goal of automated testing is to create and maintain a cohesive infrastructure of robust tests that could be run independently on a software package in its entirety. To that end, the Spaceport Command and Control System (SCCS) project at the National Aeronautics and Space Administration's (NASA) Kennedy Space Center (KSC) has brought in a large group of interns to work side-by-side with full time employees to do just this work. Thus, our job is to implement the tests that will put SCCS through its paces.

  12. Deep Borehole Field Test Requirements and Controlled Assumptions.

    Energy Technology Data Exchange (ETDEWEB)

    Hardin, Ernest [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-07-01

    This document presents design requirements and controlled assumptions intended for use in the engineering development and testing of: 1) prototype packages for radioactive waste disposal in deep boreholes; 2) a waste package surface handling system; and 3) a subsurface system for emplacing and retrieving packages in deep boreholes. Engineering development and testing is being performed as part of the Deep Borehole Field Test (DBFT; SNL 2014a). This document presents parallel sets of requirements for a waste disposal system and for the DBFT, showing the close relationship. In addition to design, it will also inform planning for drilling, construction, and scientific characterization activities for the DBFT. The information presented here follows typical preparations for engineering design. It includes functional and operating requirements for handling and emplacement/retrieval equipment, waste package design and emplacement requirements, borehole construction requirements, sealing requirements, and performance criteria. Assumptions are included where they could impact engineering design. Design solutions are avoided in the requirements discussion. Deep Borehole Field Test Requirements and Controlled Assumptions July 21, 2015 iv ACKNOWLEDGEMENTS This set of requirements and assumptions has benefited greatly from reviews by Gordon Appel, Geoff Freeze, Kris Kuhlman, Bob MacKinnon, Steve Pye, David Sassani, Dave Sevougian, and Jiann Su.

  13. German boiler and pressure vessel codes and standards: materials, manufacture, testing, equipment, erection and operation

    International Nuclear Information System (INIS)

    Steffen, H.P.

    1987-01-01

    The methods by which the safety objectives on the operation of steam boilers and pressure vessels in Germany can be reached are set out in Technical Rules which are compiled and established in technical committees. Typical applications are described in the Technical Rules. A chart shows how the laws, provisions and Technical Rules for the sections 'steam boiler plant' and 'pressure vessels' are interlinked. This chapter concentrates on legal aspects, materials, manufacture, testing, erection and operation of boilers and pressure vessels in Germany. (U.K.)

  14. Quality control of brachytherapy equipment in the Netherlands and Belgium: current practice and minimum requirements

    International Nuclear Information System (INIS)

    Elfrink, Robert J.M.; Kolkman-Deurloo, Inger-Karine K.; Kleffens, Herman J. van; Rijnders, Alex; Schaeken, Bob; Aalbers, Tony H.L.; Dries, Wim J.F.; Venselaar, Jack L.M.

    2002-01-01

    Background and purpose: Brachytherapy is applied in 39 radiotherapy institutions in The Netherlands and Belgium. Each institution has its own quality control (QC) programme to ensure safe and accurate dose delivery to the patient. The main goal of this work is to gain insight into the current practice of QC of brachytherapy in The Netherlands and Belgium and to reduce possible variations in test frequencies and tolerances by formulating a set of minimum QC-requirements. Materials and methods: An extensive questionnaire about QC of brachytherapy was distributed to and completed by the 39 radiotherapy institutions. A separate smaller questionnaire was sent to nine institutions performing intracoronary brachytherapy. The questions were related to safety systems, physical irradiation parameters and total time spent on QC. The results of the questionnaires were compared with recommendations given in international brachytherapy QC reports. Results: The answers to the questionnaires showed large variations in test frequencies and test methods. Furthermore, large variations in time spent on QC exist, which is mainly due to differences in QC-philosophy and differences in the available resources. Conclusions: Based on the results of the questionnaires and the comparison with the international recommendations, a set of minimum requirements for QC of brachytherapy has been formulated. These guidelines will be implemented in the radiotherapy institutions in The Netherlands and Belgium

  15. Metrological analysis of constancy tests in conventional medical X-ray equipment

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Oliveira, Paulo Marcio C.; Squair, Peterson L.; Soares, Carlos M.; Silva, Teogenes A. da

    2005-01-01

    Constancy tests in x-ray diagnostic machines should follow performance requirements with the aim to verify their safety and quality and to protect workers, patients and public members that are or may be exposed to ionizing radiation risks. In the Brazilian state of Minas Gerais, from 1999 to 2004, 110 radiometric and evaluation reports of x-ray machines were issued by accredited professionals. Most of the reports did not provide the estimation of the measurement uncertainty that should be part of the results; it means that there is a lack of metrological care in such reports which may cause difficulties to get a conclusive analysis. In this work, relevant sources of uncertainties were identified and estimated for the following tests carried out in a conventional x-ray machine: high voltage accuracy and reproducibility, air kerma rate repeatability and linearity and half-value layer determination. This work gives details on the methodology and the expanded and combined uncertainty values for each measuring procedure, which may be adopted as representative values for analysis of radiometric report. (author)

  16. Quality control for the equipment of Nuclear medicine: experience of the H.U. de la Princesa; Control de calidad del equipamiento en Medicina Nuclear. Experiencia enel H.U. de la Princesa

    Energy Technology Data Exchange (ETDEWEB)

    Espana, M.L.; Gracia, A.; Prieto, C.; Lopez F, P. [Servicio de ProteccionRadiologica. Hospital Universitario de la Princesa C/ Diego de Leon 62, 28006Madrid (Spain)

    1998-12-31

    The quality control of the equipment used in a nuclear medicine service is a fundamental aspect in the Quality Assurance Program that in the present time is starting in our hospital. the objective of this work is to present the internal protocol used, its problematic associated with its starting, and the results obtained in the quality control as of the gamma camera as of the activimeter. In addition to the equipment own to the nuclear medicine service it has been used a Cs-137 source and puppets for several purposes. The results obtained demonstrated the stability of the controlled parameters which has led us to a restating of the established periodicities in our internal protocol, over all for some constancy tests. (Author)

  17. Case Study of the Failure of two 13.8kV Control & Metering Transformers that caused significant Equipment Damage

    Energy Technology Data Exchange (ETDEWEB)

    Dreifuerst, G R; Chew, D B; Mangonon, H L; Swyers, P W

    2011-08-25

    The degradation and failure of cast-coil epoxy windings within 13.8kV control power transformers and metering potential transformers has been shown to be dangerous to both equipment and personnel, even though best industrial design practices were followed. Accident scenes will be examined for two events at a U.S. Department of Energy laboratory. Failure modes will be explained and current design practices discussed with changes suggested to prevent a recurrence and to minimize future risk. New maintenance philosophies utilizing partial discharge testing of the transformers as a prediction of end-of-life will be examined.

  18. Wind-Tunnel Tests of a Bridge Model with Active Vibration Control

    DEFF Research Database (Denmark)

    Hansen, H. I.; Thoft-Christensen, Palle; Mendes, P. A.

    The application of active control systems to reduce wind vibrations in bridges is a new area of research. This paper presents the results that were obtained on a set of wind tunnel tests of a bridge model equipped with active movable flaps. Based on the monitored position and motion of the deck...

  19. POC-scale testing of an advanced fine coal dewatering equipment/technique

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, J.G.; Parekh, B.K. [Univ. of Kentucky, Lexington, KY (United States); Rawls, P. [Department of Energy, Pittsburgh, PA (United States)

    1995-11-01

    Froth flotation technique is an effective and efficient process for recovering of ultra-fine (minus 74 {mu}m) clean coal. Economical dewatering of an ultra-fine clean coal product to a 20 percent level moisture will be an important step in successful implementation of the advanced cleaning processes. This project is a step in the Department of Energy`s program to show that ultra-clean coal could be effectively dewatered to 20 percent or lower moisture using either conventional or advanced dewatering techniques. As the contract title suggests, the main focus of the program is on proof-of-concept testing of a dewatering technique for a fine clean coal product. The coal industry is reluctant to use the advanced fine coal recovery technology due to the non-availability of an economical dewatering process. in fact, in a recent survey conducted by U.S. DOE and Battelle, dewatering of fine clean coal was identified as the number one priority for the coal industry. This project will attempt to demonstrate an efficient and economic fine clean coal slurry dewatering process.

  20. Controlling stress corrosion cracking in mechanism components of ground support equipment

    Science.gov (United States)

    Majid, W. A.

    1988-01-01

    The selection of materials for mechanism components used in ground support equipment so that failures resulting from stress corrosion cracking will be prevented is described. A general criteria to be used in designing for resistance to stress corrosion cracking is also provided. Stress corrosion can be defined as combined action of sustained tensile stress and corrosion to cause premature failure of materials. Various aluminum, steels, nickel, titanium and copper alloys, and tempers and corrosive environment are evaluated for stress corrosion cracking.

  1. Improved efficiency access control equipment and explosive, weapons and drug abuse detection

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, A.; Milford, A.; Woollven, J.

    1985-01-01

    The second generation portal explosives detector has been designed with increased detection capability and convenience in service. The method of detection and performance relative to the first generation is described. A novel method of auto-calibration and self diagnosis is described and results are discussed. Improvements in convenience of operation have been achieved and operating space and costs reduced by combining metal detection capability, together with explosives detection. This allows both alarm signal and diagnostic outputs to be combined on a single remote panel in the guard room, and reduces the number of guards needed to man the access control. This type of access control is entirely a defensive measure against attack but a further additional feature is proposed which will also check the state of mind of all personnel passing through the check point. Any person suffering from the effect of narcotic or alcohol will be detected by their inability to reproduce their normal signature. A new method of signature analysis in five dimensions is described together with proposals for integrating the check without increasing the time in the test area. Some recent results on the effects of alcohol on signature reproduction is given.

  2. a New Design for Diamond Window Equipped Paris-Edinburgh — First Tests and Results

    Science.gov (United States)

    Burchard, M.; Glasmacher, U. A.; Dedera, S.; Trautmann, C.

    2012-12-01

    High pressure cells of the Paris-Edinburgh type are important tools for experimental high pressure studies in material science. Although these cells were originally developed for use in neutron diffraction, today they are also applied in alternative experimental high pressure fields. Their main advantages are their small construction size, limited weight and the relative high reachable pressures with a maximized sample volume. The small construction size also results in very good cost efficiency. The major drawback of these cells is that due to their simple squeezer geometry pressure extrapolations are nearly impossible and, hence, the use of internal standard is mandatory. Consequently, the normal use of Paris-Edinburgh cells is mostly limited to experiments with neutron or synchrotron radiation, during which pressure and temperature are determined by using an internal diffraction standard. To overcome this problem, tone may combine the advantages of diamond anvil cells with those of Paris-Edinburgh-cells by integrating diamond windows into the upper and / or the lower anvil. With such a cell it is possible to retrieve pressure and / or temperature data by measuring the shift of Raman bands or fluorescence lines by spectroscopic methods. Several attempts have been made to build such a cell ([1] and Klotz pers. communication) using different window materials. Until now no final setup has been published. We present a new Paris-Edinburgh cell design especially constructed for use within high energy relativistic heavy ion radiation experiments. This design uses conventional diamond anvils as spectroscopic windows in conjunction with specially designed hardened steel anvils. We have performed first feasibility studies up to 2.5 GPa with a standard Raman spectrometer using a special adapted Raman glass fiber probe. We present results of several mechanical test runs and one experiment with relativistic heavy ion radiation at the GSI Helmholtzzentrum f

  3. Cryogenic controls for the TESLA test facility

    Science.gov (United States)

    Clausen, M.; Gerke, Chr.; Knopf, U.; Rettig, S.; Schoeneburg, B.

    1994-12-01

    The TESLA Test Facility (TTF) is designed to perform intensive testing of the superconducting cavities foreseen for the next generation of linear colliders. The cryogenic system is one part of this facility. The controls for this system will initially use the existing software and hardware to be able to cool down the first cavities fabricated in the TTF workshop. Later the control system will be modified to meet the current standards in process and accelerator controls. The hardware will be changed to use the VME system as the major platform. The operating system and the communication will be based on de-facto standards such as UNIX for the workstations and the front-end computers and TCP/IP for network communication. The application software (EPICS) will be part of a collaboration with several other institutes. The final goal is to port all the software to the POSIX standard and to use Object-Oriented tools wherever possible. The first part of this paper describes the migration from the existing control system to the future design. Special decisions on hardware and software solutions are highlighted. Nonproprietary field busses for remote process I/O are becoming usual for slow control. A suitable bus for our future basic I/O system had to be selected. Finally a new temperature monitor module working on the CAN-bus and its measurement procedure will be explained.

  4. Multi-Moulding Unit Operator (dental equip.) 712.884; Heater Operator (dental equip.) 712.884--Technical Report on Development of USES Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  5. International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST); Volume 1: Cases E100-E200

    Energy Technology Data Exchange (ETDEWEB)

    Neymark, J.; Judkoff, R.

    2002-01-01

    This report describes the Building Energy Simulation Test for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST) project conducted by the Tool Evaluation and Improvement International Energy Agency (IEA) Experts Group. The group was composed of experts from the Solar Heating and Cooling (SHC) Programme, Task 22, Subtask A. The current test cases, E100-E200, represent the beginning of work on mechanical equipment test cases; additional cases that would expand the current test suite have been proposed for future development.

  6. Evaluation of ring shear testing as a characterization method for powder flow in small-scale powder processing equipment.

    Science.gov (United States)

    Søgaard, Søren Vinter; Pedersen, Troels; Allesø, Morten; Garnaes, Joergen; Rantanen, Jukka

    2014-11-20

    Powder flow in small-scale equipment is challenging to predict. To meet this need, the impact of consolidation during powder flow characterization, the level of consolidation existing during discharge of powders from a tablet press hopper and the uncertainty of shear and wall friction measurements at small consolidation stresses were investigated. For this purpose, three grades of microcrystalline cellulose were used. Results showed that powder flow properties depend strongly on the consolidation during testing. The consolidation during discharge in terms of the major principal stress and wall normal stress were approximately 200 Pa and 114 Pa, respectively, in the critical transition from the converging to the lower vertical section of the hopper. The lower limit of consolidation for the shear and wall friction test was approximately 500 Pa and 200 Pa, respectively. At this consolidation level, the wall and shear stress resolution influences the precision of the measured powder flow properties. This study highlights the need for an improved experimental setup which would be capable of measuring the flow properties of powders under very small consolidation stresses with a high shear stress resolution. This will allow the accuracy, precision and applicability of the shear test to be improved for pharmaceutical applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Establishment of nuclear equipment qualification system

    International Nuclear Information System (INIS)

    Joo, Po Kook; Lim, Nam Jin; Lee, Young Gun

    2003-04-01

    This study is carried out by KEARI(Korea Atomic Energy Research Institute) as the lead organization in cooperation with KIMM(Korea Institute of Machinery and Materials), KTL(Korea Testing Laboratory) and KRISS(Korea Research Institute of Standards and Science) to construct a basis of efficient management of nuclear equipment qualification business by expanding test equipment of each of participating organization, and developing qualification technologies. As for KIMM, control system of large scale shaker was replaced with advanced system, and LOCA(Loss of Coolant Accident) test facility was installed. KTL is now capable of conducting seismic tests of nuclear I and C as a result of installation of seismic test equipment during the first two project years. KRISS participated in the Project with a view to have large scale EMI test equipment and related technologies. In parallel with expansion of test equipment, a industrial-educational-research cooperation committee, as an intermediate step toward integrated equipment qualification system to maximize the usage of test equipment, was established and cooperation methods were investigated. As a result, Korea Nuclear Equipment Qualification Association, an corporate juridical person, was established. Research on development of thermal and radiation aging test technology of nuclear materials was carried out by Hanyang University and SECO(Saehan Engineering and Qualification Co., Ltd.). Integrated Equipment Qualification Database was developed which contains material test data, equipment qualification data and other EQ related informations. Standard qualification procedures were developed in order for test laboratories and manufacturers to establish design requirements and to efficiently perform tests

  8. Improvement of nuclear power plant monitor and control equipment. Computer application backfitting

    International Nuclear Information System (INIS)

    Hayakawa, H.; Kawamura, A.; Suto, O.; Kinoshita, Y.; Toda, Y.

    1985-01-01

    This paper describes the application of advanced computer technology to existing Japanese Boiling Water Reactor (BWR) nuclear power plants for backfitting. First we review the background of the backfitting and the objectives of backfitting. A feature of backfitting such as restrictions and constraints imposed by the existing equipment are discussed and how to overcome these restrictions by introduction of new technology such as highly efficient data transmission using multiplexing, and compact space saving computer systems are described. Role of the computer system in reliable NPS are described with a wide spectrum of TOSHIBA backfitting computer system application experiences. (author)

  9. Control substances and alcohol use and testing

    Energy Technology Data Exchange (ETDEWEB)

    Przybylski, J.L.

    1994-07-01

    The Omnibus Transportation Employee Testing Act was signed into law in October of 1991. The Omnibus Transportation Employee Testing Act of 1991 required the United States Department of Transportation (DOT) to enact regulations requiring the testing of employees that perform ``safety sensitive functions`` for illegal controlled substance use and alcohol misuse. The Transportation Management Division, Office of Environmental Restoration and Waste Management (TMD/EM-261), United States Department of Energy (DOE), Training Program Manager is committed to promoting the availability of the necessary information to those affected members of the Department of Energy (DOE) community in an effort to attain the highest possible level of regulatory compliance and to enhance the safety of each individual in the workplace.

  10. Design and Realization of Integrated Management System for Data Interoperability between Point-of-Care Testing Equipment and Hospital Information System.

    Science.gov (United States)

    Park, Ki Sang; Heo, Hyuk; Choi, Young Keun

    2013-09-01

    The purpose of this study was to design an integrated data management system based on the POCT1-A2, LIS2-A, LIS2-A2, and HL7 standard to ensure data interoperability between mobile equipment, such as point-of-care testing equipment and the existing hospital data system, its efficiency was also evaluated. The method of this study was intended to design and realize a data management system which would provide a solution for the problems that occur when point-of-care testing equipment is introduced to existing hospital data, after classifying such problems into connectivity, integration, and interoperability. This study also checked if the data management system plays a sufficient role as a bridge between the point-of-care testing equipment and the hospital information system through connection persistence and reliability testing, as well as data integration and interoperability testing. In comparison with the existing system, the data management system facilitated integration by improving the result receiving time, improving the collection rate, and by enabling the integration of disparate types of data into a single system. And it was found out that we can solve the problems related to connectivity, integration and interoperability through generating the message in standardized types. It is expected that the proposed data management system, which is designed to improve the integration point-of-care testing equipment with existing systems, will establish a solid foundation on which better medical service may be provided by hospitals by improving the quality of patient service.

  11. Exercise Equipment: Neutral Buoyancy

    Science.gov (United States)

    Shackelford, Linda; Valle, Paul

    2016-01-01

    Load Bearing Equipment for Neutral Buoyancy (LBE-NB) is an exercise frame that holds two exercising subjects in position as they apply counter forces to each other for lower extremity and spine loading resistance exercises. Resistance exercise prevents bone loss on ISS, but the ISS equipment is too massive for use in exploration craft. Integrating the human into the load directing, load generating, and motion control functions of the exercise equipment generates safe exercise loads with less equipment mass and volume.

  12. Launch Control System Software Development System Automation Testing

    Science.gov (United States)

    Hwang, Andrew

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administration's (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This system requires high quality testing that will measure and test the capabilities of the system. For the past two years, the Exploration and Operations Division at Kennedy Space Center (KSC) has assigned a group including interns and full-time engineers to develop automated tests to save the project time and money. The team worked on automating the testing process for the SCCS GUI that would use streamed simulated data from the testing servers to produce data, plots, statuses, etc. to the GUI. The software used to develop automated tests included an automated testing framework and an automation library. The automated testing framework has a tabular-style syntax, which means the functionality of a line of code must have the appropriate number of tabs for the line to function as intended. The header section contains either paths to custom resources or the names of libraries being used. The automation library contains functionality to automate anything that appears on a desired screen with the use of image recognition software to detect and control GUI components. The data section contains any data values strictly created for the current testing file. The body section holds the tests that are being run. The function section can include any number of functions that may be used by the current testing file or any other file that resources it. The resources and body section are required for all test files; the data and function sections can be left empty if the data values and functions being used are from a resourced library or another file. To help equip the automation team with better tools, the Project Lead of the Automated Testing Team, Jason Kapusta, assigned the task to install and train an optical character recognition (OCR

  13. Design and adjustment on test bed of replacing subassembly machine control system for China experimental fast reactor

    International Nuclear Information System (INIS)

    Dong Shengguo; Ma Hongsheng; Zhao Lixia

    2008-01-01

    The present research concerns in the design and adjustment of replacing sub- assembly machine control system of China Experimental Fast Reactor. The design of replacing subassembly machine control system adopts some electric equipments, such as programmable controllers, digital DC drivers. The designed control system was adjusted on the test bed. The results indicate that the operation of the control system is steady and reliable, and designed control system can meet the needs of the design specification. (authors)

  14. Testing objects in Computerized Axial Tomography. Contributions to the Spanish Protocol on quality control in radiodiagnostics

    International Nuclear Information System (INIS)

    Villaescusa, J.I.; Campayo, J.M.

    1995-01-01

    In the provisional version of the Spanish Protocol about the technical aspects of Quality Control in Radiodiagnostic,SEFM-SEPR 1993, it is dedicated a section to Computerized Axial tomography, establishing a total of eleven technical parameters of the equipment for examination. The present work describes the practical use of the Protocol using various types of Test Object. The authors also propose new tests that should be considered in the final version of the Spanish Protocol. (Author)

  15. Ten years of sodium cooled steam generator tests on the C.G.V.S. Synthesis of the results obtained on these equipments and operation experiments of an industrial size test facility

    International Nuclear Information System (INIS)

    Fontaine, J.P.; Llory, M.; Quinet, J.L.

    1984-04-01

    From 1970 to 1980, Electricite de France carried out tests on four steam generators of the fast neutron reactor series on an industrial size testing equipment, the C.G.V.S. (large power testing Circuit for Steam Generators heated by Sodium). After a presentation of the testing installation, types of tests carried out and tested apparatus, a balance of lessons drawn from the circuit exploitation, and from the main results obtained on the tested equipments and on the means of calculation COPI and SICLE codes developed or adopted to simulate steam generator operation. 33 figs., 50 refs [fr

  16. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    International Nuclear Information System (INIS)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design

  17. Microcomputer-based equipment-control and data-acquisition system for fission-reactor reactivity-worth measurements

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, W.P.; Bucher, R.G.

    1980-01-01

    Material reactivity-worth measurements are one of the major classes of experiments conducted on the Zero Power research reactors (ZPR) at Argonne National Laboratory. These measurements require the monitoring of the position of a servo control element as a sample material is positioned at various locations in a critical reactor configuration. In order to guarantee operational reliability and increase experimental flexibility for these measurements, the obsolete hardware-based control unit has been replaced with a microcomputer based equipment control and data acquisition system. This system is based on an S-100 bus, dual floppy disk computer with custom built cards to interface with the experimental system. To measure reactivity worths, the system accurately positions samples in the reactor core and acquires data on the position of the servo control element. The data are then analyzed to determine statistical adequacy. The paper covers both the hardware and software aspects of the design.

  18. Development of the electromagnetic tomography system. Field test results using existing equipment; EM tomography system no kaihatsu. Kison sochi ni yoru test sokutei kekka

    Energy Technology Data Exchange (ETDEWEB)

    Kumekawa, Y.; Miura, Y.; Takasugi, S. [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Arai, E. [Metal Mining Agency of Japan, Tokyo (Japan)

    1996-05-01

    With the purpose of developing an electromagnetic tomography system, an observation was carried out with existing equipment combined, and the data was analyzed. The measuring equipment consisted of existing borehole vertical magnetic field sensors as the sensor part, MT method receivers as the receiving device, and existing CSMT method transmitters as the transmitting device. The measuring was performed at the Richmond Field Station which was abundant in existing data and which had a comparatively simple resistivity structure. The borehole vertical magnetic field sensors were lowered inside the borehole, and signal sources were arranged at 10m apart on the traverse line in the direction from northeast to southwest with the borehole as the center. The analysis of the data was made with the use of EM1D by three models, namely, 10 ohm{center_dot}m homogeneous earth model, 100 ohm{center_dot}m homogeneous earth model, and horizontal 7 layer model prepared on the basis of electric logging results; and a comparative examination was made against the measured data. As a result, it was demonstrated that the test measurement agreed very well with the model from the electric logging results and that it was the data reflecting a resistivity structure. 8 refs., 6 figs.

  19. Parallel controller construction for a multi-DOF hand rehabilitation equipment

    Science.gov (United States)

    Ito, Satoshi; Ueki, Satoshi; Ishihara, Koji; Miura, Masayuki; Kawasaki, Haruhisa; Ishigure, Yasuhiko; Nishimoto, Yutakai

    2007-12-01

    This paper describes the development of a hand rehabilitation system for stroke patients. Our aim is to provide fine motion exercise for a hand and fingers. Thus, a hand rehabilitation device that assists patients' finger movements was developed. Because this device has 18 degrees of freedom of motion, it is diffcult for disabled patients to use it by themselves. Therefore, an appropriate control strategy and control system are required to allow its safe and effective use. In light of this requirement, a control system was constructed which is comprised of four separated controllers. This paper presents the structure of the control system and introduces the control protocols used in our hand rehabilitation system.

  20. Quality control tests for conventional mammography

    International Nuclear Information System (INIS)

    Dawod, Alnazer Ahmed Ibrahim

    2014-12-01

    Mammography is this the test that allows the radiologist to look at images of the inside of the breasts. Mammograms help detect breast cancer early successful treatment of breast cancer depends on that early diagnosis. Breast cancer is a very common condition. About one in every nine women develops breast cancer by the age of eighty. In addition to the clinical examination and self-examination, mammography plays important role in the detection of breast cancer before they become clinically visible tumors. The mammography is the most common test for early detection of breast cancer. Quality control techniques that done ensured importance of this programme to produce images with good diagnostic values and help radiologist to diagnose breast discase easily and avoid exposing patient to radiation hazards.(Author)

  1. 77 FR 35310 - Revisions to the Export Administration Regulations (EAR): Control of Military Training Equipment...

    Science.gov (United States)

    2012-06-13

    .... 120202094-2065-01] RIN 0694-AF54 Revisions to the Export Administration Regulations (EAR): Control of..., as part of the Administration's ongoing Export Control Reform Initiative, BIS published a proposed... multilateral export control regimes. Accordingly, the Administration will, in this and subsequent proposed...

  2. Nuclear electronic equipment for control and monitoring boards. MCH/MENT Recommendations

    International Nuclear Information System (INIS)

    Roquefort, H.

    1975-01-01

    The constitution of the group ''Materiel de Controle Homologue - Materiel Electronique Nucleaire pour Tableaux de controle et de commande'' is given. This group has to define, work out, and propose general and particular specifications related to reactor control-board instrumentation. These specifications are useful in France and abroad. Published documents are listed [fr

  3. Condition Monitoring Techniques for Electromechanical Equipment Used in Air Force Ground C3I (Command, Control, Communications and Intelligence) Systems.

    Science.gov (United States)

    1983-08-01

    electromechanical equipment failures impact these two primary mis- sions. The AN/FPS-115 radar phased array consists of 1792 individual crossed dipole elements...level could approach a megawatt if the option to double the * number of dipoles is exercised. The transmit/receive modules are mounted on water cooled...Toulouse, 1975, 224 p. PAU L.F., Diagnostic statistique, L’Onde Electrique , Vol 54, n0 10, december 1974, 529-537 PAU L.F., Sequencing laboratory tests for

  4. Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment

    International Nuclear Information System (INIS)

    Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

    1995-07-01

    Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed

  5. First steps in quality control equipment MRI; Primeros pasos en el control de calidad de equipos de imagen por resonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Diaz, M.; Castaneda Arronte, M. J.; Ferreiros Vazquez, N.; Sanchez Merino, G.

    2011-07-01

    The present work aims to develop the initial stages of a program of quality control of nuclear magnetic resonance equipment. Not intended to conduct a comprehensive study covering all aspects of quality control, but gather the steps are followed and the most common problems they are encountering during the development of this program. It has been claimed that the work will be helpful to others facing the same task. Have been studied the compatibility of mannequins and procedures for the various teams. Ideally, such controls should be independent of the procedures and mannequins own commercial houses.

  6. Monitoring and measurement of variables - assurance of observability and controllability of the reactor equipment

    International Nuclear Information System (INIS)

    Durnev, V.N.; Mitelman, M.G.

    2001-01-01

    The presentation presents main conclusions on the basis of analysis of the existing situation with assurance of observability and controllability of the reactor installation. A methodology of classification of variables of the controlled object state and proposals on selection and substantiation of measurement and inspection monitoring techniques is given. Main problems associated with assurance of observability and controllability of the reactor installation are presented for various operation modes. (Authors)

  7. On the choice of structures of equipment for preliminary data processing for a data acquisition subsystem of the automation control system for controlling technological parameters of tokamak devices

    International Nuclear Information System (INIS)

    Bondarenko, I.M.; Gerasimov, V.P.; Mozin, I.V.; Repin, S.S.; Skosarev, V.A.

    1982-01-01

    The necessity is substantiated to use a complex approach to constructing measuring channels of data acquisition subsystems in automation control systems for controlling technological processes in tokamak thermonuclear installations including preliminary data processing equipment, incorporated devices and measuring converters, which enables to minimize the whole bulk of equipment units, while attaining the best metrological features of the channels. Some examples are given designing measuring channels for different kind of signals. Special attention is paid to the choice of structures of measuring channels for signals from sensors under high voltage isolated from the ground potential. It is found reasonable to use analog-time data conversion and optoelectronic isolating elements from the viewpoint of simplicity of apparatus, good manufacturing technology and adjusting measuring channels elements

  8. GD SDR Automatic Gain Control Characterization Testing

    Science.gov (United States)

    Nappier, Jennifer M.; Briones, Janette C.

    2013-01-01

    The General Dynamics (GD) S-Band software defined radio (SDR) in the Space Communications and Navigation (SCAN) Testbed on the International Space Station (ISS) will provide experimenters an opportunity to develop and demonstrate experimental waveforms in space. The GD SDR platform and initial waveform were characterized on the ground before launch and the data will be compared to the data that will be collected during on-orbit operations. A desired function of the SDR is to estimate the received signal to noise ratio (SNR), which would enable experimenters to better determine on-orbit link conditions. The GD SDR does not have an SNR estimator, but it does have an analog and a digital automatic gain control (AGC). The AGCs can be used to estimate the SDR input power which can be converted into a SNR. Tests were conducted to characterize the AGC response to changes in SDR input power and temperature. This purpose of this paper is to describe the tests that were conducted, discuss the results showi ng how the AGCs relate to the SDR input power, and provide recommendations for AGC testing and characterization.

  9. Technology test results from an intelligent, free-flying robot for crew and equipment retrieval in space

    Science.gov (United States)

    Erickson, Jon D.; Goode, R.; Grimm, K. A.; Hess, Clifford W.; Norsworthy, Robert S.; Anderson, Greg D.; Merkel, L.; Phinney, Dale E.

    1992-03-01

    The ground-based demonstrations of Extra Vehicular Activity (EVA) Retriever, a voice- supervised, intelligent, free-flying robot, are designed to evaluate the capability to retrieve objects (astronauts, equipment, and tools) which have accidentally separated from the space station. The EVA Retriever software is required to autonomously plan and execute a target rendezvous, grapple, and return to base while avoiding stationary and moving obstacles with subsequent object handover. The software architecture incorporates a hierarchical decomposition of the control system that is horizontally partitioned into five major functional subsystems: sensing, perception, world model, reasoning, and acting. The design provides for supervised autonomy as the primary mode of operation. It is intended to be an evolutionary system improving in capability over time and as it earns crew trust through reliable and safe operation. This paper gives an overview of the hardware, a focus on software, and a summary of results achieved recently from both computer simulations and air bearing floor demonstrations. Limitations of the technology used are evaluated. Plans for the next phase, during which moving targets and obstacles drive realtime behavior requirements, are discussed.

  10. Maintenance related to life management: Survey and control of equipment ageing

    International Nuclear Information System (INIS)

    Hevia Ruperez, F.

    2000-01-01

    The aim of this paper is to review relevant objectives and aspects of the Maintenance Evaluation and Improvement Programmes for Nuclear Power Plant Life Management. Recent experience shows that current maintenance practice often fails to directly address long-term degradation that affects singular plant components and equipment populations. Instead, delayed attention to the consequences makes good Life Management unfeasible. This has brought about the need for specific Maintenance Evaluation and Improvement Programmes to adjust to the basic objective of Life Management which is to protect against, mitigate and/or monitor ageing that affects the safe, profitable life of the facility. The paper analyses the methodologies used, incidents during their application and the main conclusions reached from the implementation of these programmes in Spanish nuclear power plants. Special attention is paid to recommended solutions for improving the efficiency of the utility's contributions, its leadership in task development and integration, and its interfaces with organisations specialised in providing services that support Life Management Programmes. The coexistence of these and other similar maintenance programmes make it necessary to integrate tasks to optimise effort and tools. The paper analyses the guidelines to be considered when integrating these Programmes with other maintenance optimisation programmes (economy and feasibility, RCM) and with tasks derived from the application of Maintenance Rule regulatory requirements. Lastly, the paper reports on the state of these Maintenance Evaluation and Improvement Programmes, their development, what prospects they have, and the Industry's initiative and actions concerning the matter. (author)

  11. 77 FR 72851 - California State Nonroad Engine Pollution Control Standards; Portable Equipment Registration...

    Science.gov (United States)

    2012-12-06

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9758-1] California State Nonroad Engine Pollution Control... otherwise covered by a within-the-scope confirmation. \\11\\ See California State Nonroad Engine Pollution... Pollution Control Standards; Authorization of Large Off-Road Spark- Ignition Engine Standards, Notice of...

  12. Cooperation during the assembling and testing of prototypes of the Chemical Equipment Research Institute at the Bohunice II nuclear power plant

    International Nuclear Information System (INIS)

    Brzobohaty, J.

    1989-01-01

    Technico-legal documentation (Technical Specifications for Supply, Assembling, Operation and Maintenance and the Individual Program of Quality Assurance) is characterized for prototypes of equipment for the final processing of radioactive wastes at the Bohunice nuclear plant, manufactured by the Chemical Equipment Research Institute in Brno. The on-the-spot assembling of the prototypes is briefly described, and a program of pre-complex and complex performance tests is proposed. The Jabsco pump for a Voronezh-type model concentrate was tested; the parameters are compared with the manufacturer's data. (author). 2 figs., 9 refs

  13. Simulation Research on Adaptive Control of a Six-degree-of-freedom Material-testing Machine

    Directory of Open Access Journals (Sweden)

    Dan Wang

    2014-02-01

    Full Text Available This paper presents an adaptive controller equipped with a stiffness estimation method for a novel material-testing machine, in order to alleviate the performance depression caused by the stiffness variance of the tested specimen. The dynamic model of the proposed machine is built using the Kane method, and kinematic model is established with a closed-form solution. The stiffness estimation method is developed based on the recursive least-squares method and the proposed stiffness equivalent matrix. Control performances of the adaptive controller are simulated in detail. The simulation results illustrate that the proposed controller can greatly improve the control performance of the target material-testing machine by online stiffness estimation and adaptive parameter tuning, especially in low-cycle fatigue (LCF and high-cycle fatigue (HCF tests.

  14. Application of new control technology during the maintenance of equipment in the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Ojeda R, M. A.

    2008-01-01

    In the nuclear power plant of Laguna Verde, in normal operation and recharges are carried out activities of preventive maintenance and corrective to different equipment, due to the one displacement of radioactive materials from the vessel of the reactor until the one system of vapor, different radiation levels are generated (from low until very high) in the circuits of vapor and water, the particles can be incrusted on those interior surfaces of the pipes and equipment, creating this way a potential risk of contamination and exhibition during the maintenance of equipment. To help to optimize the dose to the personnel the use of new technology the has been implemented which besides contributing an absolute control of the work, it offers bigger comfort to the one worker during the development of their work, also contributing a supervision more effective of the same one. Using the captured and processed information of the work developed you can use for the personnel's capacitation and feedback of the work for the continuous improvement of the same one. During a reduction of programmed power and normal operation are carried out maintenance correctives and specific works to preserve the readiness and ability of the equipment and with this to maintain the security of the nuclear power plant. The development of the theme it is showing the advances and commitments of personnel to take to excellence to the nuclear power plant of Laguna Verde showing to the obtained results of the dose and benefits of 2 works carried out in the nuclear power plant where tools ALARA were applied as well as the use of the new technology (Video Equipment of Tele dosimetry and Audio 'VETA') in works carried out in the building of purification level 10.15, change and cuts of filter of the prefilters of system G16, as well as,the retirement and transfer for its decay of High Integrity Container (HIC) of the building of purification level -0.55 to the Temporary Warehouse in Site. Works of high

  15. Design and control of a direct drive wind turbine equipped with multilevel converters

    Energy Technology Data Exchange (ETDEWEB)

    Abbes, Mohamed [LSE-ENIT, P.O Box 37, Belvedere, 1002 Tunis (Tunisia); Belhadj, Jamel [LSE-ENIT, P.O Box 37, Belvedere, 1002 Tunis (Tunisia); ESSTT, P.O. Box 56, Monfleury, 1008 Tunis (Tunisia); Ben Abdelghani Bennani, Afef [LSE-ENIT, P.O Box 37, Belvedere, 1002 Tunis (Tunisia); INSAT, P.O. Box 676, North Urban Centre, 1080 Tunis (Tunisia)

    2010-05-15

    This paper concentrates on the design and control of a three-level grid side converter (GSC) for direct drive high power wind turbines. The three-level, neutral point clamped (NPC) topology was investigated. The proposed control scheme, based on vector current control, offers very satisfying performances regarding to structure stability and grid connection requirements (GCR). In order to have an accurate evaluation of grid voltage source, two grid synchronization methods are developed and their performances are compared. The GSC performances are evaluated under both normal and grid fault conditions. Simulation results show that stability is maintained during voltage dips and that the proposed direct drive wind turbine satisfies completely GCR. (author)

  16. A Theoretical Method of Determining the Control Gearing and Time Lag Necessary for a Specified Damping of an Aircraft Equipped with a Constant-Time-Lag Autopilot

    National Research Council Canada - National Science Library

    Gates, Ordway

    1951-01-01

    A method is presented for determining the control gearing and time lag necessary for a specified damping of the motions of an aircraft equipped with an autopilot having constant-time-lag characteristics...

  17. Shell Chemical LP To Install $10 Million In Pollution Monitoring And Control Equipment At Norco Chemical Facility In Louisiana To Resolve Alleged Federal And State Clean Air Violations

    Science.gov (United States)

    EPA News Release: Shell Chemical LP To Install $10 Million In Pollution Monitoring And Control Equipment At Norco Chemical Facility In Louisiana To Resolve Alleged Federal And State Clean Air Violations

  18. Automatic Control of Shower Equipment for Elderly People or People with Physical Disabilities

    OpenAIRE

    ZHAO, QILIANG; ZHANG, FAN; ZHOU, YAQI

    2013-01-01

    In this thesis an electronically controlled movable chair is designed to be connected to the door of a shower. A bathroom model was created using Autodesk Inventor, and materials were researched and selected for modeling before doing a static simulation. A dynamic simulation was then carried out to simulate the vertical motion of the chair; the driving torque was generated at the same time. Based on the driving torque, a direct current motor which connects with a system controlling the vertic...

  19. General Attitude Control Algorithm for Spacecraft Equipped with Star Camera and Reaction Wheels

    DEFF Research Database (Denmark)

    Wisniewski, Rafal; Kulczycki, P.

    A configuration consisting of a star camera, four reaction wheels and magnetorquers for momentum unloading has become standard for many spacecraft missions. This popularity has motivated numerous agencies and private companies to initiate work on the design of an imbedded attitude control system...... applying the energy shaping technique, where the desired potential function is carefully designed using a physical insight into the nature of the problem. The system stability is thoroughly analyzed and the control performance simulated...

  20. Challenges and Opportunities for Transactive Control of Electric Vehicle Supply Equipment. A Reference Guide

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Xin [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Meintz, Andrew [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-07-29

    This report seeks to characterize the opportunities and challenges that arise in developing a transactive control strategy for grid-EVSE integration in various use-case scenarios in a way that provides end-user, energy market, grid, and societal benefits. A detailed review provides information about EVSE integration market trends and stakeholder activities. This is followed by an exploration of value proposition for transactive control of EVSE at both the home scale and the building/campus scale. This report will serve as a reference guide for stakeholders in the grid-EVSE integration area, illustrate potential implementations, and identify a high-value research project for overcoming the barriers and unlocking the benefits of transactive controls of EVSE. While it is not intended to specify the technical details of the transactive control solution, the report contains a list of use cases describing potential applications of transactive control of EVSE, barriers to implementing these applications, and research and development (R&D) opportunities to overcome the barriers. The use cases of transactive control of EVSE are listed in Table ES1.

  1. REDUCTION IN CUTS SPEED AT THE BEGINNING OF A SORTING SIDINGS, EQUIPPED WITH QUASI-CONTINUOUS SPEED CONTROL SYSTEM

    Directory of Open Access Journals (Sweden)

    O. A. Nazarov

    2016-08-01

    Full Text Available Purpose. Clear and uninterrupted operation of humps depends on the quality of technical equipment and control technology of cuts speed. Technology of interval and purposive regulation of cuts speed is used at most humps. The article discusses ways to reduce the cuts rolling speed to a safe level at the beginning of the sorting sidings equipped with quasi-continuous speed control system. Methodology. It proposed three fundamentally different ways to reduce the cuts rolling speed at the beginning of the sorting siding. The analysis of the ways to reduce cuts rolling speed to a safe level at the beginning of the sorting sidings was conducted using simulation the process of cuts rolling from humps equipped with quasi-continuous speed control. Findings. As a result of analysis, the inappropriateness of opposite elevation using on the roll-out part of the hump after the last separation switch point. Spot regulators of cars speed can be used to reduce the cuts rolling speed at the beginning of the sorting siding, but this leads to a division conditions deterioration on the last separating switch points of long cuts with the following after them short cuts. Reducing the cuts rolling speed at the beginning of the sorting siding can be carried out using the beam on a stationary wagon retarders park brake position. Control Algorithm park brake position is quite simple. All produce should be unhooked from it at a safe speed. If the accuracy of the implementation of the set speed output to unhook from the park brake position is low, it is possible to eliminate the error of point regulators cars speed. Originality. The question where to start location point of wagon retarders zone to reduce speed to cut level requires additional research. Reducing rolling cut the speed at the beginning of the sorting sidings can be carried out using the beam on a stationary wagon retarders park brake position. Practical value. Control Algorithm park brake position is quite

  2. Process control for the Vivitron: the generator test set-up

    International Nuclear Information System (INIS)

    Lutz, J.R.; Marsaudon, J.C.; Baumann, R.; Kapps, E.; Knaebel, R.; Persigny, J.

    1992-01-01

    The VIVITRON is a 35 MV Van de Graaff tandem electrostatic accelerator under construction at the CRN since 1985. About half of the parameters are controlled by equipments which are highly stressed by their physical environment: sparks, electrostatic field, X-rays, vacuum, and gas pressure. It needs a dedicated process control system. The described control system is used since early 1991 to perform the voltage tests of the generator. It provides important information for the accelerator tuning and for the full size control under development. (author)

  3. Development of Universal Methodology of Specimen Free Nondestructive Inspection (Control) of Mechanical Properties of NPP Equipment Metal in all Stages of Lifetime

    International Nuclear Information System (INIS)

    Bakirov, M.; Chubarov, S.; Frolov, I.; Kiselev, I.; Gastrock, J.; Dripke, M.

    2011-01-01

    Ever-increasing requirements for reliability and safety of equipment in nuclear power plants (NPP) dictate a necessity to obtain reliable and validated information about the condition of materials in the most safety-relevant and economically vital systems structures and components (SSC). Thus it is a state of science and technology approach to use one method, one methodic and one methodology to facilitate these goals with the purpose of keeping NPPs operating safely by virtue of knowing the state of ageing they are in (with respect to design limits and margins). Method of the control/measurement/testing - how to conduct measurements; methodic - how to interpret the results of measurement; methodology - the program of the control/inspection and testing programmes: localities to conduct the tests, how often, and to follow evolution of test results with the aim of acting before a failure occurs. Such methodology should be based on the use of specimen-free nondestructive method of the inspection (control), which could be used, successfully at all stages of life cycle of the equipment: manufacturing, construction, installation of NPP, operation and during the NPP operation through integration into the Plant Life Management (PLiM) Programme. It will facilitate a real picture of change (degradation) of a SSC material's condition in the zones subjected to the harshest stressors (neutron irradiation, erosion-corrosion/flow, thermal fatigue, vibration etc). Currently, there are various approaches used in the world to follow NPP ageing degradation, but until now, no specific methodology is used that could supply all the necessary information. Therefore, there is no way to use various results. Thanks to considerable advances over the last 20 years or so, the science of hardness testing offers an elegant, non-destructive way to obtain vital materials properties - even in-situ on operating SSC. In particular, the material's elastic-plastic condition may be measured, giving

  4. Calibration voltage test of non invasive meter for radiodiagnostic on equipment of constant potential X-ray

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Pereira, Marco A.G.S.

    2009-01-01

    This work evaluates the utilization of the non invasive voltage meter PTW Diavolt Universal in industrial X ray equipment of constant potential. With the performed measurements, the conclusion is that conclusion is possible, once his use limits are identified

  5. Redundant and fault-tolerant algorithms for real-time measurement and control systems for weapon equipment.

    Science.gov (United States)

    Li, Dan; Hu, Xiaoguang

    2017-03-01

    Because of the high availability requirements from weapon equipment, an in-depth study has been conducted on the real-time fault-tolerance of the widely applied Compact PCI (CPCI) bus measurement and control system. A redundancy design method that uses heartbeat detection to connect the primary and alternate devices has been developed. To address the low successful execution rate and relatively large waste of time slices in the primary version of the task software, an improved algorithm for real-time fault-tolerant scheduling is proposed based on the Basic Checking available time Elimination idle time (BCE) algorithm, applying a single-neuron self-adaptive proportion sum differential (PSD) controller. The experimental validation results indicate that this system has excellent redundancy and fault-tolerance, and the newly developed method can effectively improve the system availability. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Precise in situ etch depth control of multilayered III−V semiconductor samples with reflectance anisotropy spectroscopy (RAS equipment

    Directory of Open Access Journals (Sweden)

    Ann-Kathrin Kleinschmidt

    2016-11-01

    Full Text Available Reflectance anisotropy spectroscopy (RAS equipment is applied to monitor dry-etch processes (here specifically reactive ion etching (RIE of monocrystalline multilayered III–V semiconductors in situ. The related accuracy of etch depth control is better than 16 nm. Comparison with results of secondary ion mass spectrometry (SIMS reveals a deviation of only about 4 nm in optimal cases. To illustrate the applicability of the reported method in every day settings for the first time the highly etch depth sensitive lithographic process to form a film lens on the waveguide ridge of a broad area laser (BAL is presented. This example elucidates the benefits of the method in semiconductor device fabrication and also suggests how to fulfill design requirements for the sample in order to make RAS control possible.

  7. The effects of physical training without equipment on pain perception and balance in the elderly: A randomized controlled trial

    Science.gov (United States)

    Patti, Antonino; Bianco, Antonino; Karsten, Bettina; Montalto, Maria Alessandra; Battaglia, Giuseppe; Bellafiore, Marianna; Cassata, Daniela; Scoppa, Fabio; Paoli, Antonio; Iovane, Angelo; Messina, Giuseppe; Palma, Antonio

    2017-01-01

    BACKGROUND: Research supports a link between exercise and falls prevention in the older population. OBJECTIVES: Our aims were to evaluate pain perception and balance skills in a group of elderly subjects and to examine the consequences of a standardized equipment-free exercise program intervention on these variables. The study utilized a randomized controlled trial method. METHODS: 92 subjects were recruited from a rural Sicilian village (Resuttano, Sicily, Italy). Subjects were randomly split into two groups, an experimental group (EG; n = 49) and a control group (CG; n = 43). Qualified fitness instructors delivered the standardized physical exercise program for the EG whilst the CG did not receive this exercise intervention. The Berg Balance Scale and the Oswestry Disability Index were administered in both groups before (T0) and after the intervention (T1). RESULTS: At T1, the EG group significantly improvement in balance (p disability in elderly. PMID:28506013

  8. Effect of long-term exposure of 2.4 GHz radiofrequency radiation emitted from Wi-Fi equipment on testes functions.

    Science.gov (United States)

    Dasdag, Suleyman; Taş, Muzaffer; Akdag, Mehmet Zulkuf; Yegin, Korkut

    2015-03-01

    The aim of this study was to investigate long-term effects of radiofrequency radiation (RFR) emitted from a Wireless Fidelity (Wi-Fi) system on testes. The study was carried out on 16 Wistar Albino adult male rats by dividing them into two groups such as sham (n: 8) and exposure (n: 8). Rats in the exposure group were exposed to 2.4 GHz RFR radiation for 24 h/d during 12 months (1 year). The same procedure was applied to the rats in the sham control group except the Wi-Fi system was turned off. Immediately after the last exposure, rats were sacrificed and reproductive organs were removed. Motility (%), concentration (×10(6)/mL), tail defects (%), head defects (%) and total morphologic defects (%) of sperms and weight of testes (g), left epididymis (g), prostate (g), seminal vesicles (g) were determined. Seminiferous tubules diameter (μm) and tunica albuginea thickness (μm) were also measured. However, the results were evaluated by using Johnsen's score. Head defects increased in the exposure group (p  0.05). In conclusion, we observed that long-term exposure of 2.4 GHz RF emitted from Wi-Fi (2420 μW/kg, 1 g average) affects some of the reproductive parameters of male rats. We suggest Wi-Fi users to avoid long-term exposure of RF emissions from Wi-Fi equipment.

  9. Controlling Beryllium Contaminated Material And Equipment For The Building 9201-5 Legacy Material Disposition Project

    International Nuclear Information System (INIS)

    Reynolds, T.D.; Easterling, S.D.

    2010-01-01

    This position paper addresses the management of beryllium contamination on legacy waste. The goal of the beryllium management program is to protect human health and the environment by preventing the release of beryllium through controlling surface contamination. Studies have shown by controlling beryllium surface contamination, potential airborne contamination is reduced or eliminated. Although there are areas in Building 9201-5 that are contaminated with radioactive materials and mercury, only beryllium contamination is addressed in this management plan. The overall goal of this initiative is the compliant packaging and disposal of beryllium waste from the 9201-5 Legacy Material Removal (LMR) Project to ensure that beryllium surface contamination and any potential airborne release of beryllium is controlled to levels as low as practicable in accordance with 10 CFR 850.25.

  10. The Effects of Test Format and Locus of Control on Test Anxiety.

    Science.gov (United States)

    Choi, Namok

    1998-01-01

    Investigates the joint effects of locus of control and test format on test anxiety with college students (N=86). Examines the relationship between students' attitudes toward test format and test anxiety. Results show no differential effect of locus of control on test anxiety across test format; students were more anxious about essay tests than…

  11. Maintenance and fabrication of nuclear electronic equipment

    International Nuclear Information System (INIS)

    Hong, Seok Boong; Chung, Chong Eun; Hwang, In Koo; Koo, In Soo; Park, Bum; Kim, Soo Hee; Lee, Seong Joo; Kim, Min Seok; Choi, Wha Lim

    2011-12-01

    - process equipment at PIEF, Chemical Analysis Team and RWFTF have been calibrated. - The electronic equipment and radiation equipment at RWTF and PIEF have been prepared. - Development and installation of integrated RMS software for Hanaro Cold Neutron Laboratory Building(CNLB) RMS, and development and performance upgrade of a portal monitor for CNLB. - Performance test of the Hardware/Software of digital unit controller has been performed, and functional upgrade of the Hardware/Software of stimulator for SMART MMIS performance test facility has also been performed. - A controller of high voltage power supply for a small electron beam generator and a controller for razer pinning and a remote monitoring apparatus of cathode power supply for a 0.2 Mev. small electron beam generator have been designed and fabricated. - Database construction for effective maintenance for the process equipment and radiation instruments are designed and constructed

  12. Maintenance and fabrication of nuclear electronic equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seok Boong; Chung, Chong Eun; Hwang, In Koo; Koo, In Soo; Park, Bum; Kim, Soo Hee; Lee, Seong Joo; Kim, Min Seok; Choi, Wha Lim [KAERI, Daejeon (Korea, Republic of)

    2011-12-15

    - process equipment at PIEF, Chemical Analysis Team and RWFTF have been calibrated. - The electronic equipment and radiation equipment at RWTF and PIEF have been prepared. - Development and installation of integrated RMS software for Hanaro Cold Neutron Laboratory Building(CNLB) RMS, and development and performance upgrade of a portal monitor for CNLB. - Performance test of the Hardware/Software of digital unit controller has been performed, and functional upgrade of the Hardware/Software of stimulator for SMART MMIS performance test facility has also been performed. - A controller of high voltage power supply for a small electron beam generator and a controller for razer pinning and a remote monitoring apparatus of cathode power supply for a 0.2 Mev. small electron beam generator have been designed and fabricated. - Database construction for effective maintenance for the process equipment and radiation instruments are designed and constructed.

  13. Slew Maneuver Control for Spacecraft Equipped with Star Camera and Reaction Wheels

    DEFF Research Database (Denmark)

    Wisniewski, Rafal; Kulczycki, P.

    2005-01-01

    A configuration consisting of a star camera, four reaction wheels and magnetorquers for momentum unloading has become standard for many spacecraft missions. This popularity has motivated numerous agencies and private companies to initiate work on the design of an imbedded attitude control system ...... performance simulated. A detailed simulation study shows convincing results for the entire range of operation. Udgivelsesdato: MAR......A configuration consisting of a star camera, four reaction wheels and magnetorquers for momentum unloading has become standard for many spacecraft missions. This popularity has motivated numerous agencies and private companies to initiate work on the design of an imbedded attitude control system...

  14. Microprocessor system for calibration and control of the equipment in RISK experiments

    International Nuclear Information System (INIS)

    Glasnek, K.-P.; Merekov, Yu.P.; Pishka, K.; Pflugbajl', V.; Fal'kenberg, V.; Khernesh, I.; Khovanskij, N.N.

    1979-01-01

    Described is an autonomous CAMAC system based on the intel-8080 microprocessor to provide calibration and control of the apparatus in the RISK. Secondary particle magnetic spectrometer with a streamer chamber installed on the Serpukhov accelerator. It consists of the beam crate, few event crates and the intelligent crate. As the mini-computer and dedicated crate controller currently used in small CAMAC system, are being supersided by the intelligent crate with ''build-in'' microprocessor, this system is a very low cost solution for data acquisition and processing

  15. Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Daily III, W D

    2010-02-24

    This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300

  16. Nanotechnology based surface treatments for corrosion protection and deposit control of power plant equipment. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-05-15

    Nanotechnology can provide possibilities for obtaining new valuable information regarding performance and corrosion protection in power plants. In general the desired performance of the contact surfaces is an easy-to-release effect. This is in order to prolong the time interval between cleaning periods or make the cleaning procedures easier and less expensive. Corrosion protection is also desired in order to extend the life time of various parts in the power plants and thus optimize the energy output and overall efficiency of the plant. Functional sol-gel coating based on nanotechnology is tested in a variety of conditions. Applications of functional sol-gel coatings were performed in the condenser and on seven air preheaters at Fynsvaerket, Odense, with corrosion protection as the main issue. Coatings with easy-to-clean effects were tested in the Flue Gas Desulphurization plant at Nordjyllandsvaerket, Aalborg, with the aim of reducing gipsum deposit. Thermo stabilized coatings were tested on tube bundles between in the passage from the 1st to 2end pass and on the wall between 1st and 2end pass at Amagervaerket, Copenhagen, and in the boiler at Haderslev CHP plant. The objective of this test were reducing deposits and increasing corrosion protection. The tested coatings were commercial available coatings and coatings developed in this project. Visual inspections have been performed of all applications except at Nordjyllandsvaerket. Corrosion assessment has been done at DTU - Mechanical Engineering. The results range from no difference between coated and uncoated areas to some improvements. At Amagervaerket the visual assessment showed in general a positive effect with a sol-gel hybrid system and a commercial system regarding removal of deposits. The visual assessment of the air preheaters at Fynsvaerket indicates reduced deposits on a sol-gel nanocomposite coated air preheater compared to an uncoated air preheater. (Author)

  17. Maintenance of medical nuclear equipment. A proposal for quality control in radiotherapy

    International Nuclear Information System (INIS)

    Becker, Paulo H.B.

    1996-01-01

    A project of quality control in radiotherapy that is been implemented by Instituto de Radioprotecao e Dosimetria from Brazilian National Energy Commission (CNEN) in cooperation with International Atomic Energy Agency is described. The establishment of a laboratory for the maintenance of medical dosemeters is proposed

  18. Potential and limitations of modern equipment for real time control of urban wastewater systems

    DEFF Research Database (Denmark)

    Campisano, A.; Cabot Ple, J.; Muschalla, D.

    2013-01-01

    Real Time Control (RTC) has become an accepted technique for improving the performance of Urban Drainage Systems (UDS) due to its flexibility and sustainability. Numerous implementations of RTC have been reported during the last decades. At the same time, guideline documents and state-of-the-art ...

  19. Computational energy analysis of an innovative isothermal chamber for testing of the special equipment used in the transport of perishable products

    Energy Technology Data Exchange (ETDEWEB)

    Chatzidakis, S.K.; Chatzidakis, K.S. [National Technical Univ., Athens (Greece). Dept. of Mechanical Engineering; Athienitis, A. [Concordia Univ., Quebec (Canada). Dept. of Building, Civil and Environmental Engineering

    2004-07-01

    This paper describes an improved numerical simulation study of an isothermal chamber recently constructed at Zografou Campus of the National Technical University of Athens (NTUA) for the testing of special equipment used for transporting perishable foodstuffs in accordance with the United Nations ATP agreement. Using a transient finite difference model, a simulation is developed for a modern ATP test chamber and a typical specimen refrigerated vehicle to be tested. The simulation results are compared to experimental measurements taken under real conditions by a data acquisition system and a refrigerated semi-trailer as specimen. Proportional-integral control is employed for the regulation of the cooling and heating system. The impact of various parameters on the time required to reach the set-point temperature (t{sub set}) is investigated and the energy consumption is simulated for a period of 22 h. In particular, the impact of specimen insulation thickness and the thickness of the chamber insulation floor are considered in detail. The total energy consumption increases by approximately 16% when the concrete floor layer thickness is increased from 8 to 16 cm for typical initial conditions and desired chamber and specimen temperatures of 32.5 and 7.5{sup o}C, respectively. Using a floor insulation of 6 cm extruded heavy strain-resistant polystyrene reduces the energy consumption by at least 13%. Specimen insulation thickness increase from U-value of 0.35 W m{sup -2} K to 0.75 W m{sup -2} K results in an increase in energy consumption by a percentage of 28%. Thermal capacity, temperature of car body and specimen dimensions are also treated as variables that affect the total duration of an ATP test and its total energy consumption. [Author].

  20. Resolution of Unresolved Safety Issue A-48, ''Hydrogen control measures and effects of hydrogen burns on safety equipment''

    International Nuclear Information System (INIS)

    Ferrell, C.M.; Soffer, L.

    1989-09-01

    Unresolved Safety Issue (USI) A-48 arose as a result of the large amount of hydrogen generated and burned within containment during the Three Mile Island accident. This issue covers hydrogen control measures for recoverable degraded-core accidents for all boiling-water reactors (BWRs) and those pressurized-water reactors (PWRs) with ice-condenser containments. The Commission and the nuclear industry have sponsored extensive research in this area, which has led to significant revision of the Commission's hydrogen control regulations, given in Title 10, Code of Federal Regulations, Part 50 (10 CFR 50), Section 50.44. BWRs having Mark I and II containments are presently required to operate with inerted containment atmospheres that effectively prevent hydrogen combustion. BWRs with Mark III containments and PWRs with ice-condenser containments are now required to be equipped with hydrogen control systems to protect containment integrity and safety systems inside containment. Industry has chosen to use hydrogen igniter systems to burn hydrogen produced in a controlled fashion to prevent damage. An independent review by a Committee of the National Research Council concluded that, for most accident scenarios, current regulatory requirements make it highly unlikely that hydrogen detonation would be the cause of containment failure. On the basis of the extensive research effort conducted and current regulatory requirements, including their implementation, the staff concludes that no new regulatory guidance on hydrogen control for recoverable degraded-core accidents for these types of plants is necessary and that USI A-48 is resolved

  1. Special equipment for the fabrication and quality control of nuclear fuel elements

    International Nuclear Information System (INIS)

    Guse, K.; Herbert, W.; Jaeger, K.

    1989-01-01

    For the fabrication of LWR fuel elements, columns are packed of up to 4 m in length, consisting of fuel pellets with different uranium enrichment, their weight and total length to be measured prior to further processing to fuel rods. An automated column packing device has been developed for this purpose. The packing jobs and other tasks are computer-controlled, measured data are stored and are printed out for quality documentation. The forces in the springs of fuel spacers of LWR fuel elements are to be measured and compared with the standard requirements, deviations to be documented. For this task, another computer-controlled, automated device has been developed for measuring the spring forces at all required positions after positioning and fixation of the spacers. (orig./DG) [de

  2. Retrofit SCR system for NOx control from heavy-duty mining equipment

    International Nuclear Information System (INIS)

    Mannan, M.A.

    2009-01-01

    Diesel engines are used extensively in the mining industry and offer many advantages. However, particulate matter (PM) emissions and nitrogen oxide emissions (NOx) are among its disadvantages. A significant concern related to PM and NOx in an underground mine involves the use of diesel exhaust after treatment systems such as diesel particulate filters and selective catalytic reduction (SCR). This presentation discussed NOx and PM control and provided a description of an SCR system and examples of SCR retrofits. Options for NOx control were discussed and a case study involving the installation of an SCR retrofit system in an underground mine operated by Sifto Salt was also presented. The purpose of the case study was to identify cost effective retrofit solutions to lower nitrogen dioxide emissions from heavy-duty trucks operating in underground mines. The case study illustrated and presented the candidate vehicle, baseline emissions, a BlueMax SCR retrofit solution, and BlueMax installation. 1 tab., 6 figs.

  3. Numerical Simulation of Electric Controlled Injection Device Equipped on Gas Fuel Engine

    OpenAIRE

    Wenqing Ge; Yanjun Zhao; Bo Li; Binbin Sun

    2014-01-01

    Since there exist the problems of engine temping and combustion instability on the heavy-duty gas fuel engine based on single-point injection system, an electronically controlled multi-point injection system utilizing moving-coil electromagnetic linear actuator and mushrooms type valve structure was developed. The influence mechanism to gas fuel intake and mixing process caused by injection pulse width and installation site of the injection device was determined by the established CFD numeric...

  4. Corrosion Prevention and Control Planning Guidebook for Military Systems and Equipment

    Science.gov (United States)

    2014-04-02

    Sacrificial coatings (e.g., galvanizing)  Surface modification (e.g., weld overlays , electro-plating)  Sealants (e.g., wet installed fasteners...operational environment should be avoided. Consider compatibility when using multiple materials. If dissimilar materials cannot be avoided, isolate those... Dissimilar Metals.  MIL-HDBK-1568, Military Handbook: Materials and Processes for Corrosion Prevention and Control in Aerospace Weapons Systems (18 July

  5. Iterative learning control for synchronization of reticle stage and wafer stage in step-and-scan lithographic equipment

    Science.gov (United States)

    Li, Lan-lan; Hu, Song; Zhao, Li-xin; Ma, Ping

    2013-08-01

    Lithographic equipments are highly complex machines used to manufacture integrated circuits (ICs). To make larger ICs, a larger lens is required, which, however, is prohibitively expensive. The solution to this problem is to expose a chip not in one flash but in a scanning fashion. For step-and-scan lithographic equipment (wafer scanner), the image quality is decided by many factors, in which synchronization of reticle stage and wafer stage during exposure is a key one. In this paper, the principle of reticle stage and wafer stage was analyzed through investigating the structure of scanners, firstly. While scanning, the reticle stage and wafer stage should scan simultaneously at a high speed and the speed ratio is 1:4. Secondly, an iterative learning controller (ILC) for synchronization of reticle stage and wafer stage is presented. In the controller, a master-slave structure is used, with the wafer stage acting as the master, and the reticle stage as the slave. Since the scanning process of scanner is repetitive, ILC is used to improve tracking performance. A simple design procedure is presented which allows design of the ILC system for the reticle stage and wafer stage independently. Finally, performance of the algorithm is illustrated by simulated on the virtual stages (the reticle stage and wafer stage).The results of simulation experiments and theory analyzing demonstrate that using the proposed controller better synchronization performance can be obtained for the reticle stage and wafer stage in scanner. Theory analysis and experiment shows the method is reasonable and efficient.

  6. Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

    Energy Technology Data Exchange (ETDEWEB)

    Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

    2011-09-01

    Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads

  7. Provision and testing of remote handling equipment to dismantle nuclear facilities, based on a current project of the WAK BGmbH

    International Nuclear Information System (INIS)

    Hendrich, K.

    1992-01-01

    The remotely handled dismantling of the cell OIId could be successfully demonstrated in a test stand. Within the framework of the test stand operation for remotely handled dismantling of about 3.5 Mp of technical equipment, the following data could be determined: planned personnel service time within the radiation field of 8 manh; expected collective dose of ∝0.02 manSv, and planned remotely handled dismantling time of the cell OIId of 52 days. (orig.) [de

  8. Torque coordinating robust control of shifting process for dry dual clutch transmission equipped in a hybrid car

    Science.gov (United States)

    Zhao, Z.-G.; Chen, H.-J.; Yang, Y.-Y.; He, L.

    2015-09-01

    For a hybrid car equipped with dual clutch transmission (DCT), the coordination control problems of clutches and power sources are investigated while taking full advantage of the integrated starter generator motor's fast response speed and high accuracy (speed and torque). First, a dynamic model of the shifting process is established, the vehicle acceleration is quantified according to the intentions of the driver, and the torque transmitted by clutches is calculated based on the designed disengaging principle during the torque phase. Next, a robust H∞ controller is designed to ensure speed synchronisation despite the existence of model uncertainties, measurement noise, and engine torque lag. The engine torque lag and measurement noise are used as external disturbances to initially modify the output torque of the power source. Additionally, during the torque switch phase, the torque of the power sources is smoothly transitioned to the driver's demanded torque. Finally, the torque of the power sources is further distributed based on the optimisation of system efficiency, and the throttle opening of the engine is constrained to avoid sharp torque variations. The simulation results verify that the proposed control strategies effectively address the problem of coordinating control of clutches and power sources, establishing a foundation for the application of DCT in hybrid cars.

  9. Evaluation of the Nuclear Medicine facilities in Minas Gerais state: quality control program of equipment; Avaliacao dos servicos de Medicina Nuclear do estado de Minas Gerais: programa de controle de qualidade dos equipamentos

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Tadeu Takao Almodovar; Biancardi, Rodrigo; Rocha, Adriana Marcia Guimaraes; Ferreira, Denia Romao; Silva, Franciele Aquiles Anjos; Assuncao, Jonathan Buenos Aires; Alves, Ederson Henrique; Almeida, Ana Flavia Batista; Alves, Nathalia Fernandes; Xavier, Faber Henrique Zacarias; Gontijo, Rodrigo Modesto Gadelha; Mamede, Marcelo, E-mail: mamede.mm@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Belo Horizonte, MG (Brazil); Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento Anatomia e Imagem

    2017-11-01

    With the reformulation of the CNEN-NN-3.05 standard in December 2013, Brazil's Nuclear Medicine (NMS) services have to perform a greater number of quality controls for SPECT and PET equipment. However, little is known about the reality of the quality control programs of these services regarding the application of the new standard. Thus, in this context, the objective of the present study was to evaluate the quality control program of MNSs in the state of Minas Gerais. All NMSs in the state of Minas Gerais were invited to participate in the project. Of these, 34.48% (20 facilities) agreed to participate in the project, 50.00% (29 facilities) did not respond to the invitation and 15.52%(9 facilities) declined their participation. Thus, as of November 2015, 20 SPECT and 2 PET/CT equipment were evaluated for the performance of the quality control tests recommended by the new CNEN standard. The phantoms required for the evaluation came from the Laboratory of Dosimetry and Quality Control of UFMG. Even with the deadlines set by CNEN for the implementation of the quality control program in the NMSs, more than 50% of the evaluated services did not implement the quality controls, and the absence of specific phantoms is the main reason for the failure. Among the problems found in the installations, the most critical were: collimators with no conditions of use in the clinical routine, linearity problems of the evaluated image and values of image uniformity superior to the limits of acceptance. Problems in the uniformity and linearity of the image found directly impacted the performance of other tests, such as spatial resolution, SPECT performance, among others. In a general way, the NMSs in the state of Minas Gerais evaluated with the present study are in clinical feasible conditions. (author)

  10. Testing and start up of equipment in a substation; Pruebas y puesta en servicio del equipo de una subestacion

    Energy Technology Data Exchange (ETDEWEB)

    Raull-Martin, J. [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-09-01

    The purpose of this paper is to present a summarized version of the test series required to determine out the final condition of the isolations, the continuity of the control circuits, as well as protection, measurement, sing-positing, alarms and the total substation performance. [Spanish] El proposito de este articulo es presentar en forma compacta la serie de pruebas que se requieren para determinar el estado final de los aislamientos, la continuidad de los circuitos de control, proteccion, medicion, senalizacion, alarmas, asi como el funcionamiento del conjunto de la subestacion. Se muestra una grafica K-Temperatura y de conexiones para las pruebas con megger. Se muestra un diagrama de conexiones para determinar las marcas de polaridad este tipo bushing e interruptores; asi como para el faseo de una proteccion diferencial. Se da el diagrama de faseo interno y energizado por el lado de 23 kV de una subestacion de 230 kV.

  11. An automated testing tool for traffic signal controller functionalities.

    Science.gov (United States)

    2010-03-01

    The purpose of this project was to develop an automated tool that facilitates testing of traffic controller functionality using controller interface device (CID) technology. Benefits of such automated testers to traffic engineers include reduced test...

  12. Dynamic assertion testing of flight control software

    Science.gov (United States)

    Andrews, D. M.; Mahmood, A.; Mccluskey, E. J.

    1985-01-01

    An experiment in using assertions to dynamically test fault tolerant flight software is described. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters.

  13. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples as...

  14. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control test for potency. (a) Quality control tests for potency of antihemophilic factor shall be conducted...

  15. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be...

  16. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335...

  17. A controllability test for general first-order representations

    NARCIS (Netherlands)

    U. Helmke; J. Rosenthal; J.M. Schumacher (Hans)

    1995-01-01

    textabstractIn this paper we derive a new controllability rank test for general first-order representations. The criterion generalizes the well-known controllability rank test for linear input-state systems as well as a controllability rank test by Mertzios et al. for descriptor systems.

  18. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good quality...

  19. Controlled Archaeological Test Site (CATS) Facility

    Data.gov (United States)

    Federal Laboratory Consortium — CATS facility is at the Construction Engineering Research Laboratory (CERL), Champaign, IL. This 1-acre test site includes a variety of subsurface features carefully...

  20. Test report - 241-AN-274 Caustic Pump Control Building

    International Nuclear Information System (INIS)

    Paintner, G.P.

    1995-05-01

    This Acceptance Test Report documents the test results of test procedure WHC-SD-WM-ATP-135 'Acceptance Test Procedure for the 241-AN- 274 Caustic Pump Control Building.' The objective of the test was to verify that the 241-AN-274 Caustic Pump Control Building functions properly based on design specifications per applicable H-2-85573 drawings and associated ECN's. The objective of the test was met