WorldWideScience

Sample records for testing accurate assessment

  1. Can blind persons accurately assess body size from the voice?

    Science.gov (United States)

    Pisanski, Katarzyna; Oleszkiewicz, Anna; Sorokowska, Agnieszka

    2016-04-01

    Vocal tract resonances provide reliable information about a speaker's body size that human listeners use for biosocial judgements as well as speech recognition. Although humans can accurately assess men's relative body size from the voice alone, how this ability is acquired remains unknown. In this study, we test the prediction that accurate voice-based size estimation is possible without prior audiovisual experience linking low frequencies to large bodies. Ninety-one healthy congenitally or early blind, late blind and sighted adults (aged 20-65) participated in the study. On the basis of vowel sounds alone, participants assessed the relative body sizes of male pairs of varying heights. Accuracy of voice-based body size assessments significantly exceeded chance and did not differ among participants who were sighted, or congenitally blind or who had lost their sight later in life. Accuracy increased significantly with relative differences in physical height between men, suggesting that both blind and sighted participants used reliable vocal cues to size (i.e. vocal tract resonances). Our findings demonstrate that prior visual experience is not necessary for accurate body size estimation. This capacity, integral to both nonverbal communication and speech perception, may be present at birth or may generalize from broader cross-modal correspondences. © 2016 The Author(s).

  2. Accurate control testing for clay liner permeability

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, R J

    1991-08-01

    Two series of centrifuge tests were carried out to evaluate the use of centrifuge modelling as a method of accurate control testing of clay liner permeability. The first series used a large 3 m radius geotechnical centrifuge and the second series a small 0.5 m radius machine built specifically for research on clay liners. Two permeability cells were fabricated in order to provide direct data comparisons between the two methods of permeability testing. In both cases, the centrifuge method proved to be effective and efficient, and was found to be free of both the technical difficulties and leakage risks normally associated with laboratory permeability testing of fine grained soils. Two materials were tested, a consolidated kaolin clay having an average permeability coefficient of 1.2{times}10{sup -9} m/s and a compacted illite clay having a permeability coefficient of 2.0{times}10{sup -11} m/s. Four additional tests were carried out to demonstrate that the 0.5 m radius centrifuge could be used for linear performance modelling to evaluate factors such as volumetric water content, compaction method and density, leachate compatibility and other construction effects on liner leakage. The main advantages of centrifuge testing of clay liners are rapid and accurate evaluation of hydraulic properties and realistic stress modelling for performance evaluations. 8 refs., 12 figs., 7 tabs.

  3. Building, testing and validating a set of home-made von Frey filaments: a precise, accurate and cost effective alternative for nociception assessment.

    Science.gov (United States)

    de Sousa, Marcelo Victor Pires; Ferraresi, Cleber; de Magalhães, Ana Carolina; Yoshimura, Elisabeth Mateus; Hamblin, Michael R

    2014-07-30

    A von Frey filament (vFF) is a type of aesthesiometer usually made of nylon perpendicularly held in a base. It can be used in paw withdrawal pain threshold assessment, one of the most popular tests for pain evaluation using animal models. For this test, a set of filaments, each able to exert a different force, is applied to the animal paw, from the weakest to the strongest, until the paw is withdrawn. We made 20 low cost vFF using nylon filaments of different lengths and constant diameter glued perpendicularly to the ends of popsicle sticks. They were calibrated using a laboratory balance scale. Building and calibrating took around 4h and confirmed the theoretical prediction that the force exerted is inversely proportional to the length and directly proportional to the width of the filament. The calibration showed that they were precise and accurate. We analyzed the paw withdrawal threshold assessed with the set of home-made vFF and with a high quality commercial set of 5 monofilaments vFF (Stoelting, Wood Dale, USA) in two groups (n=5) of healthy mice. The home-made vFF precisely and accurately measured the hind paw withdrawal threshold (20.3±0.9 g). The commercial vFF have different diameters while our set has the same diameter avoiding the problem of lower sensitivity to larger diameter filaments. Building a set of vFF is easy, cost effective, and depending on the kind of tests, can increase precision and accuracy of animal nociception evaluation. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Foresight begins with FMEA. Delivering accurate risk assessments.

    Science.gov (United States)

    Passey, R D

    1999-03-01

    If sufficient factors are taken into account and two- or three-stage analysis is employed, failure mode and effect analysis represents an excellent technique for delivering accurate risk assessments for products and processes, and for relating them to legal liability. This article describes a format that facilitates easy interpretation.

  5. Home Circadian Phase Assessments with Measures of Compliance Yield Accurate Dim Light Melatonin Onsets.

    Science.gov (United States)

    Burgess, Helen J; Wyatt, James K; Park, Margaret; Fogg, Louis F

    2015-06-01

    There is a need for the accurate assessment of circadian phase outside of the clinic/laboratory, particularly with the gold standard dim light melatonin onset (DLMO). We tested a novel kit designed to assist in saliva sampling at home for later determination of the DLMO. The home kit includes objective measures of compliance to the requirements for dim light and half-hourly saliva sampling. Participants were randomized to one of two 10-day protocols. Each protocol consisted of two back-to-back home and laboratory phase assessments in counterbalanced order, separated by a 5-day break. Laboratory or participants' homes. Thirty-five healthy adults, age 21-62 y. N/A. Most participants received at least one 30-sec epoch of light > 50 lux during the home phase assessments (average light intensity 4.5 lux), but on average for light > 50 lux or sampling errors. There was no significant difference between the home and laboratory DLMOs (P > 0.05); on average the home DLMOs occurred 9.6 min before the laboratory DLMOs. The home DLMOs were highly correlated with the laboratory DLMOs (r = 0.91, P dim light melatonin onsets (DLMOs) demonstrates that including objective measures of light exposure and sample timing during home saliva sampling can lead to accurate home DLMOs. Circadian Phase Assessments at Home, http://clinicaltrials.gov/show/NCT01487252, NCT01487252. © 2015 Associated Professional Sleep Societies, LLC.

  6. Allele-sharing models: LOD scores and accurate linkage tests.

    Science.gov (United States)

    Kong, A; Cox, N J

    1997-11-01

    Starting with a test statistic for linkage analysis based on allele sharing, we propose an associated one-parameter model. Under general missing-data patterns, this model allows exact calculation of likelihood ratios and LOD scores and has been implemented by a simple modification of existing software. Most important, accurate linkage tests can be performed. Using an example, we show that some previously suggested approaches to handling less than perfectly informative data can be unacceptably conservative. Situations in which this model may not perform well are discussed, and an alternative model that requires additional computations is suggested.

  7. Assessing autobiographical memory : The web-based autobiographical Implicit Association Test

    NARCIS (Netherlands)

    Verschuere, B.; Kleinberg, B.

    2016-01-01

    By assessing the association strength with TRUE and FALSE, the autobiographical Implicit Association Test (aIAT) [Sartori, G., Agosta, S., Zogmaister, C., Ferrara, S. D., & Castiello, U. (2008). How to accurately detect autobiographical events. Psychological Science, 19, 772–780.

  8. The accurate assessment of small-angle X-ray scattering data.

    Science.gov (United States)

    Grant, Thomas D; Luft, Joseph R; Carter, Lester G; Matsui, Tsutomu; Weiss, Thomas M; Martel, Anne; Snell, Edward H

    2015-01-01

    Small-angle X-ray scattering (SAXS) has grown in popularity in recent times with the advent of bright synchrotron X-ray sources, powerful computational resources and algorithms enabling the calculation of increasingly complex models. However, the lack of standardized data-quality metrics presents difficulties for the growing user community in accurately assessing the quality of experimental SAXS data. Here, a series of metrics to quantitatively describe SAXS data in an objective manner using statistical evaluations are defined. These metrics are applied to identify the effects of radiation damage, concentration dependence and interparticle interactions on SAXS data from a set of 27 previously described targets for which high-resolution structures have been determined via X-ray crystallography or nuclear magnetic resonance (NMR) spectroscopy. The studies show that these metrics are sufficient to characterize SAXS data quality on a small sample set with statistical rigor and sensitivity similar to or better than manual analysis. The development of data-quality analysis strategies such as these initial efforts is needed to enable the accurate and unbiased assessment of SAXS data quality.

  9. Accurate anisotropic material modelling using only tensile tests for hot and cold forming

    Science.gov (United States)

    Abspoel, M.; Scholting, M. E.; Lansbergen, M.; Neelis, B. M.

    2017-09-01

    Accurate material data for simulations require a lot of effort. Advanced yield loci require many different kinds of tests and a Forming Limit Curve (FLC) needs a large amount of samples. Many people use simple material models to reduce the effort of testing, however some models are either not accurate enough (i.e. Hill’48), or do not describe new types of materials (i.e. Keeler). Advanced yield loci describe the anisotropic materials behaviour accurately, but are not widely adopted because of the specialized tests, and data post-processing is a hurdle for many. To overcome these issues, correlations between the advanced yield locus points (biaxial, plane strain and shear) and mechanical properties have been investigated. This resulted in accurate prediction of the advanced stress points using only Rm, Ag and r-values in three directions from which a Vegter yield locus can be constructed with low effort. FLC’s can be predicted with the equations of Abspoel & Scholting depending on total elongation A80, r-value and thickness. Both predictive methods are initially developed for steel, aluminium and stainless steel (BCC and FCC materials). The validity of the predicted Vegter yield locus is investigated with simulation and measurements on both hot and cold formed parts and compared with Hill’48. An adapted specimen geometry, to ensure a homogeneous temperature distribution in the Gleeble hot tensile test, was used to measure the mechanical properties needed to predict a hot Vegter yield locus. Since for hot material, testing of stress states other than uniaxial is really challenging, the prediction for the yield locus adds a lot of value. For the hot FLC an A80 sample with a homogeneous temperature distribution is needed which is due to size limitations not possible in the Gleeble tensile tester. Heating the sample in an industrial type furnace and tensile testing it in a dedicated device is a good alternative to determine the necessary parameters for the FLC

  10. A New Generation of Leaching Tests – The Leaching Environmental Assessment Framework

    Science.gov (United States)

    Provides an overview of newly released leaching tests that provide a more accurate source term when estimating environmental release of metals and other constituents of potential concern (COPCs). The Leaching Environmental Assessment Framework (LEAF) methods have been (1) develo...

  11. A Particle Swarm Optimization Approach to Composing Serial Test Sheets for Multiple Assessment Criteria

    Science.gov (United States)

    Yin, Peng-Yeng; Chang, Kuang-Cheng; Hwang, Gwo-Jen; Hwang, Gwo-Haur; Chan, Ying

    2006-01-01

    To accurately analyze the problems of students in learning, the composed test sheets must meet multiple assessment criteria, such as the ratio of relevant concepts to be evaluated, the average discrimination degree, difficulty degree and estimated testing time. Furthermore, to precisely evaluate the improvement of student's learning performance…

  12. Can the Movement Assessment Battery for Children-Test Be the "Gold Standard" for the Motor Assessment of Children with Developmental Coordination Disorder?

    Science.gov (United States)

    Venetsanou, Fotini; Kambas, Antonis; Ellinoudis, Theodoros; Fatouros, Ioannis; Giannakidou, Dimitra; Kourtessis, Thomas

    2011-01-01

    Developmental Coordination Disorder (DCD) is an important risk factor in the development of children that can have a significant academic and social impact. This reinforces the need for its timely identification using appropriate assessment methods and accurate screening tests. The commonly used standardized motor test for the DCD identification…

  13. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  14. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    CSIR Research Space (South Africa)

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  15. Bioaccessibility tests accurately estimate bioavailability of lead to quail

    Science.gov (United States)

    Beyer, W. Nelson; Basta, Nicholas T; Chaney, Rufus L.; Henry, Paula F.; Mosby, David; Rattner, Barnett A.; Scheckel, Kirk G.; Sprague, Dan; Weber, John

    2016-01-01

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from five Pb-contaminated Superfund sites had relative bioavailabilities from 33%-63%, with a mean of about 50%. Treatment of two of the soils with phosphorus significantly reduced the bioavailability of Pb. Bioaccessibility of Pb in the test soils was then measured in six in vitro tests and regressed on bioavailability. They were: the “Relative Bioavailability Leaching Procedure” (RBALP) at pH 1.5, the same test conducted at pH 2.5, the “Ohio State University In vitro Gastrointestinal” method (OSU IVG), the “Urban Soil Bioaccessible Lead Test”, the modified “Physiologically Based Extraction Test” and the “Waterfowl Physiologically Based Extraction Test.” All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the RBALP pH 2.5 and OSU IVG tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter (24%), or present as Pb sulfate (18%). Additional Pb was associated with P (chloropyromorphite, hydroxypyromorphite and tertiary Pb phosphate), and with Pb carbonates, leadhillite (a lead sulfate carbonate hydroxide), and Pb sulfide. The formation of chloropyromorphite reduced the bioavailability of Pb and the amendment of Pb-contaminated soils with P may be a thermodynamically favored means to sequester Pb.

  16. The Osteoporosis Self-Assessment Tool versus alternative tests for selecting postmenopausal women for bone mineral density assessment: a comparative systematic review of accuracy

    DEFF Research Database (Denmark)

    Rud, B; Hilden, J; Hyldstrup, L

    2008-01-01

    for Stiffness Index assessed by calcaneal quantitative ultrasonography than for OST (relative sDOR: 1.9, p = 0.005). Studies were few in Asian and black women. Methodological quality, assessed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist, was generally low. CONCLUSIONS: In white......We performed a systematic review of studies comparing the Osteoporosis Self-Assessment Tool (OST) and other tests used to select women for bone mineral density (BMD) assessment. In comparative meta-analyses, we found that the accuracy of OST was similar to other tests that are based on information...... from the medical history. By contrast, assessment by quantitative ultrasonography at the heel was more accurate than OST in discriminating between women with high and low BMD. The methodological quality of the included studies was generally low. INTRODUCTION: Numerous tests are suggested for triaging...

  17. The use of neuropsychological tests to assess intelligence.

    Science.gov (United States)

    Gansler, David A; Varvaris, Mark; Schretlen, David J

    We sought to derive a 'neuropsychological intelligence quotient' (NIQ) to replace IQ testing in some routine assessments. We administered neuropsychological testing and a seven-subtest short form of the Wechsler Adult Intelligence Scale to a community sample of 394 adults aged 18-96 years. We regressed Wechsler Full Scale IQs (W-FSIQ) on 23 neuropsychological scores and derived an NIQ from 9 measures that explained significant variance in W-FSIQ. We then compared subgroups of 284 healthy and 108 unhealthy participants in NIQ and W-FSIQ to assess criterion validity, correlated NIQ and W-FSIQ scores with education level and independence for activities of daily living to assess convergent validity, and compared validity coefficients for the NIQ with those of 'hold' and 'no-hold' indices. By design, NIQ and W-FSIQ scores correlated highly (r = .84), and both were higher in healthy participants. The difference was larger for NIQ, which accounted for more variability in activities of daily living. The NIQ and 'no-hold' index were better predicted by health status and less predicted by educational status than the 'hold' index. We constructed an NIQ that correlates highly with Wechsler FSIQ. Tests required to obtain NIQ are commonly used and can be administered in about 45 min. Validity properties of NIQ and W-FSIQ are similar. The NIQ bore greater resemblance to a 'no-hold' than 'hold' index. One can obtain a reasonably accurate estimate of current Full Scale IQ without formal intelligence testing from a brief neuropsychological battery.

  18. Implications of the Implicit Association Test D-Transformation for Psychological Assessment.

    Science.gov (United States)

    Blanton, Hart; Jaccard, James; Burrows, Christopher N

    2015-08-01

    Psychometricians strive to eliminate random error from their psychological inventories. When random error affecting tests is diminished, tests more accurately characterize people on the psychological dimension of interest. We document an unusual property of the scoring algorithm for a measure used to assess a wide range of psychological states. The "D-score" algorithm for coding the Implicit Association Test (IAT) requires the presence of random noise in order to obtain variability. Without consequential degrees of random noise, all individuals receive extreme scores. We present results from an algebraic proof, a computer simulation, and an online survey of implicit racial attitudes to show how trial error can bias IAT assessments. We argue as a result that the D-score algorithm should not be used for formal assessment purposes, and we offer an alternative to this approach based on multiple regression. Our critique focuses primarily on the IAT designed to measure unconscious racial attitudes, but it applies to any IAT developed to provide psychological assessments within clinical, organizational, and developmental branches of psychology-and in any other field where the IAT might be used. © The Author(s) 2014.

  19. Accurate diagnosis of myalgic encephalomyelitis and chronic fatigue syndrome based upon objective test methods for characteristic symptoms

    Science.gov (United States)

    Twisk, Frank NM

    2015-01-01

    Although myalgic encephalomyelitis (ME) and chronic fatigue syndrome (CFS) are considered to be synonymous, the definitional criteria for ME and CFS define two distinct, partially overlapping, clinical entities. ME, whether defined by the original criteria or by the recently proposed criteria, is not equivalent to CFS, let alone a severe variant of incapacitating chronic fatigue. Distinctive features of ME are: muscle weakness and easy muscle fatigability, cognitive impairment, circulatory deficits, a marked variability of the symptoms in presence and severity, but above all, post-exertional “malaise”: a (delayed) prolonged aggravation of symptoms after a minor exertion. In contrast, CFS is primarily defined by (unexplained) chronic fatigue, which should be accompanied by four out of a list of 8 symptoms, e.g., headaches. Due to the subjective nature of several symptoms of ME and CFS, researchers and clinicians have questioned the physiological origin of these symptoms and qualified ME and CFS as functional somatic syndromes. However, various characteristic symptoms, e.g., post-exertional “malaise” and muscle weakness, can be assessed objectively using well-accepted methods, e.g., cardiopulmonary exercise tests and cognitive tests. The objective measures acquired by these methods should be used to accurately diagnose patients, to evaluate the severity and impact of the illness objectively and to assess the positive and negative effects of proposed therapies impartially. PMID:26140274

  20. An accurate and efficient identification of children with psychosocial problems by means of computerized adaptive testing

    NARCIS (Netherlands)

    Vogels, Antonius G. C.; Jacobusse, Gert W.; Reijneveld, Symen A.

    2011-01-01

    Background: Questionnaires used by health services to identify children with psychosocial problems are often rather short. The psychometric properties of such short questionnaires are mostly less than needed for an accurate distinction between children with and without problems. We aimed to assess

  1. Assessing autobiographical memory: the web-based autobiographical Implicit Association Test.

    Science.gov (United States)

    Verschuere, Bruno; Kleinberg, Bennett

    2017-04-01

    By assessing the association strength with TRUE and FALSE, the autobiographical Implicit Association Test (aIAT) [Sartori, G., Agosta, S., Zogmaister, C., Ferrara, S. D., & Castiello, U. (2008). How to accurately detect autobiographical events. Psychological Science, 19, 772-780. doi: 10.1111/j.1467-9280.2008.02156.x ] aims to determine which of two contrasting statements is true. To efficiently run well-powered aIAT experiments, we propose a web-based aIAT (web-aIAT). Experiment 1 (n = 522) is a web-based replication study of the first published aIAT study [Sartori, G., Agosta, S., Zogmaister, C., Ferrara, S. D., & Castiello, U. (2008). How to accurately detect autobiographical events. Psychological Science, 19, 772-780. doi: 10.1111/j.1467-9280.2008.02156.x ; Experiment 1]. We conclude that the replication was successful as the web-based aIAT could accurately detect which of two playing cards participants chose (AUC = .88; Hit rate = 81%). In Experiment 2 (n = 424), we investigated whether the use of affirmative versus negative sentences may partly explain the variability in aIAT accuracy findings. The aIAT could detect the chosen card when using affirmative (AUC = .90; Hit rate = 81%), but not when using negative sentences (AUC = .60; Hit rate = 53%). The web-based aIAT seems to be a valuable tool to facilitate aIAT research and may help to further identify moderators of the test's accuracy.

  2. Assessment and Testing.

    Science.gov (United States)

    Clapham, Caroline

    2000-01-01

    Explores the term "applied linguistics" and discusses the role of language testing within this discipline, the relationship between testing and teaching, and the relationship between testing and assessment (Author/VWL)

  3. Accurate Determination of Tunneling-Affected Rate Coefficients: Theory Assessing Experiment.

    Science.gov (United States)

    Zuo, Junxiang; Xie, Changjian; Guo, Hua; Xie, Daiqian

    2017-07-20

    The thermal rate coefficients of a prototypical bimolecular reaction are determined on an accurate ab initio potential energy surface (PES) using ring polymer molecular dynamics (RPMD). It is shown that quantum effects such as tunneling and zero-point energy (ZPE) are of critical importance for the HCl + OH reaction at low temperatures, while the heavier deuterium substitution renders tunneling less facile in the DCl + OH reaction. The calculated RPMD rate coefficients are in excellent agreement with experimental data for the HCl + OH reaction in the entire temperature range of 200-1000 K, confirming the accuracy of the PES. On the other hand, the RPMD rate coefficients for the DCl + OH reaction agree with some, but not all, experimental values. The self-consistency of the theoretical results thus allows a quality assessment of the experimental data.

  4. Shear-wave elastography contributes to accurate tumour size estimation when assessing small breast cancers

    International Nuclear Information System (INIS)

    Mullen, R.; Thompson, J.M.; Moussa, O.; Vinnicombe, S.; Evans, A.

    2014-01-01

    Aim: To assess whether the size of peritumoural stiffness (PTS) on shear-wave elastography (SWE) for small primary breast cancers (≤15 mm) was associated with size discrepancies between grey-scale ultrasound (GSUS) and final histological size and whether the addition of PTS size to GSUS size might result in more accurate tumour size estimation when compared to final histological size. Materials and methods: A retrospective analysis of 86 consecutive patients between August 2011 and February 2013 who underwent breast-conserving surgery for tumours of size ≤15 mm at ultrasound was carried out. The size of PTS stiffness was compared to mean GSUS size, mean histological size, and the extent of size discrepancy between GSUS and histology. PTS size and GSUS were combined and compared to the final histological size. Results: PTS of >3 mm was associated with a larger mean final histological size (16 versus 11.3 mm, p < 0.001). PTS size of >3 mm was associated with a higher frequency of underestimation of final histological size by GSUS of >5 mm (63% versus 18%, p < 0.001). The combination of PTS and GSUS size led to accurate estimation of the final histological size (p = 0.03). The size of PTS was not associated with margin involvement (p = 0.27). Conclusion: PTS extending beyond 3 mm from the grey-scale abnormality is significantly associated with underestimation of tumour size of >5 mm for small invasive breast cancers. Taking into account the size of PTS also led to accurate estimation of the final histological size. Further studies are required to assess the relationship of the extent of SWE stiffness and margin status. - Highlights: • Peritumoural stiffness of greater than 3 mm was associated with larger tumour size. • Underestimation of tumour size by ultrasound was associated with peri-tumoural stiffness size. • Combining peri-tumoural stiffness size to ultrasound produced accurate tumour size estimation

  5. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  6. Are general surgeons able to accurately self-assess their level of technical skills?

    Science.gov (United States)

    Rizan, C; Ansell, J; Tilston, T W; Warren, N; Torkington, J

    2015-11-01

    Self-assessment is a way of improving technical capabilities without the need for trainer feedback. It can identify areas for improvement and promote professional medical development. The aim of this review was to identify whether self-assessment is an accurate form of technical skills appraisal in general surgery. The PubMed, MEDLINE(®), Embase(™) and Cochrane databases were searched for studies assessing the reliability of self-assessment of technical skills in general surgery. For each study, we recorded the skills assessed and the evaluation methods used. Common endpoints between studies were compared to provide recommendations based on the levels of evidence. Twelve studies met the inclusion criteria from 22,292 initial papers. There was no level 1 evidence published. All papers compared the correlation between self-appraisal versus an expert score but differed in the technical skills assessment and the evaluation tools used. The accuracy of self-assessment improved with increasing experience (level 2 recommendation), age (level 3 recommendation) and the use of video playback (level 3 recommendation). Accuracy was reduced by stressful learning environments (level 2 recommendation), lack of familiarity with assessment tools (level 3 recommendation) and in advanced surgical procedures (level 3 recommendation). Evidence exists to support the reliability of self-assessment of technical skills in general surgery. Several variables have been shown to affect the accuracy of self-assessment of technical skills. Future work should focus on evaluating the reliability of self-assessment during live operating procedures.

  7. Portable, accurate toxicity testing

    International Nuclear Information System (INIS)

    Sabate, R.W.; Stiffey, A.V.; Dewailly, E.L.; Hinds, A.A.; Vieaux, G.J.

    1994-01-01

    Ever tightening environmental regulations, severe penalties for non-compliance, and expensive remediation costs have stimulated development of methods to detect and measure toxins. Most of these methods are bioassays that must be performed in the laboratory; none previously devised has been truly portable. The US Army, through the Small Business Innovative Research program, has developed a hand-held, field deployable unit for testing toxicity of battlefield water supplies. This patented system employs the measurable quenching, in the presence of toxins, of the natural bioluminescence produced by the marine dinoflagellate alga Pyrocystis lunula. The procedure's inventor used it for years to measure toxicity concentrations of chemical warfare agents actually, their simulants, primarily in the form of pesticides and herbicides plus assorted toxic reagents, waterbottom samples, drilling fluids, even blood. While the procedure is more precise, cheaper, and faster than most bioassays, until recently it was immobile. Now it is deployable in the field. The laboratory apparatus has been proven to be sensitive to toxins in concentrations as low as a few parts per billion, repeatable within a variation of 10% or less, and unlike some other bioassays effective in turbid or colored media. The laboratory apparatus and the hand-held tester have been calibrated with the EPA protocol that uses the shrimplike Mysidopsis bahia. The test organism tolerates transportation well, but must be rested a few hours at the test site for regeneration of its light-producing powers. Toxicity now can be measured confidently in soils, water columns, discharge points, and many other media in situ. Most significant to the oil industry is that drilling fluids can be monitored continuously on the rig

  8. Detailed Behavioral Assessment Promotes Accurate Diagnosis in Patients with Disorders of Consciousness

    Directory of Open Access Journals (Sweden)

    Yael eGilutz

    2015-03-01

    Full Text Available Introduction: Assessing the awareness level in patients with disorders of consciousness (DOC is made on the basis of exhibited behaviors. However, since motor signs of awareness (i.e. non-reflex motor responses can be very subtle, differentiating the vegetative from minimally conscious states (which is in itself not clear-cut is often challenging. Even the careful clinician relying on standardized scales may arrive at a wrong diagnosis. Aim: To report our experience in tackling this problem by using two in-house use assessment procedures developed at Reuth Rehabilitation Hospital, and demonstrate their clinical significance by reviewing two cases. Methods: 1.Reuth DOC Response Assessment (RDOC-RA –administered in addition to the standardized tools, and emphasizes the importance of assessing a wide range of motor responses. In our experience, in some patients the only evidence for awareness may be a private specific movement that is not assessed by standard assessment tools. 2. Reuth DOC Periodic Intervention Model (RDOC-PIM - Current literature regarding assessment and diagnosis in DOC refers mostly to the acute phase of up to one year post injury. However, we have found major changes in responsiveness occurring one year or more post-injury in many patients. Therefore, we conduct periodic assessments at predetermined times points to ensure patients are not misdiagnosed or neurological changes overlooked. Results: In the first case the RDOC-RA promoted a more accurate diagnosis than that based on standardized scales alone. The second case shows how the RDOC-PIM allowed us to recognize late recovery and promoted reinstatement of treatment with good results. Conclusions: Adding a detailed periodic assessment of DOC patients to existing scales can yield critical information, promoting better diagnosis, treatment and clinical outcomes. We discuss the implications of this observation for the future development and validation of assessment tools in

  9. PET-CT offers accurate assessment of tumour length in oesophageal malignancy

    International Nuclear Information System (INIS)

    Rollins, K.E.; Lucas, E.; Tewari, N.; James, E.; Hughes, S.; Catton, J.A.

    2015-01-01

    Highlights: • We examine the accuracy of staging modalities in estimating tumour length of oesophageal malignancy. • PET CT correlates most strongly with histopathological length of resected specimen. • Better measure than EUS with OGD correlating poorly. • Potential impact in radiotherapy and surgical resection planning. - Abstract: Introduction: Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. Materials and methods: Oesophageal cancer patients who underwent staging with PET/CT and endoscopic ultrasound (EUS) in addition to their diagnostic upper GI endoscopy and subsequent surgical resection were assessed. PET/CT length was obtained retrospectively by using Hermes Hybrid Viewer™ with a 1–5 Standardised Uptake Value grey scale. An SUV of 5 was used as the cut off for determining length. Direct measurement by EUS and OGD were determined. Results: 53 patients underwent PET-CT, EUS, OGD and surgical resection for oesophageal cancer. Overall the correlation between PET-CT and histopathological length was strongest (Pearson r = 0.5977, 95% CI 0.390–0.747) versus EUS (Pearson R = 0.5365, 95% CI 0.311–0.705) and OGD (Pearson r = 0.1574, 95% CI −0.118 to 0.410). After excluding tumours with a significant chemotherapy response, PET-CT length correlated significantly with histopathological length (R = 0.5651, p = 0.0005). In comparison, the correlation between histological length and EUS (R = 0.4637, p = 0.0057) measurement was less significant and this did not correlate with OGD (R = −0.1084, p = 0.5417). Conclusion: Tumour length estimated by PET-CT correlated most strongly with histopathological length of oesophageal malignancy and is the most accurate determinant of tumour length of all the staging modalities. This suggests a

  10. PET-CT offers accurate assessment of tumour length in oesophageal malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Rollins, K.E., E-mail: james.catton@nuh.nhs.uk [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Lucas, E. [University of Nottingham, Derby Road, Nottingham (United Kingdom); Tewari, N. [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); James, E. [Department of Oncology, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Hughes, S. [Department of Radiology, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom); Catton, J.A. [Department of Oesophago-Gastric Surgery, Nottingham University Hospitals, Hucknall Road, Nottingham (United Kingdom)

    2015-02-15

    Highlights: • We examine the accuracy of staging modalities in estimating tumour length of oesophageal malignancy. • PET CT correlates most strongly with histopathological length of resected specimen. • Better measure than EUS with OGD correlating poorly. • Potential impact in radiotherapy and surgical resection planning. - Abstract: Introduction: Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. Materials and methods: Oesophageal cancer patients who underwent staging with PET/CT and endoscopic ultrasound (EUS) in addition to their diagnostic upper GI endoscopy and subsequent surgical resection were assessed. PET/CT length was obtained retrospectively by using Hermes Hybrid Viewer™ with a 1–5 Standardised Uptake Value grey scale. An SUV of 5 was used as the cut off for determining length. Direct measurement by EUS and OGD were determined. Results: 53 patients underwent PET-CT, EUS, OGD and surgical resection for oesophageal cancer. Overall the correlation between PET-CT and histopathological length was strongest (Pearson r = 0.5977, 95% CI 0.390–0.747) versus EUS (Pearson R = 0.5365, 95% CI 0.311–0.705) and OGD (Pearson r = 0.1574, 95% CI −0.118 to 0.410). After excluding tumours with a significant chemotherapy response, PET-CT length correlated significantly with histopathological length (R = 0.5651, p = 0.0005). In comparison, the correlation between histological length and EUS (R = 0.4637, p = 0.0057) measurement was less significant and this did not correlate with OGD (R = −0.1084, p = 0.5417). Conclusion: Tumour length estimated by PET-CT correlated most strongly with histopathological length of oesophageal malignancy and is the most accurate determinant of tumour length of all the staging modalities. This suggests a

  11. The Role of Alternative Testing Strategies in Environmental Risk Assessment of Engineered Nanomaterials

    DEFF Research Database (Denmark)

    Hjorth, Rune; Holden, Patricia; Hansen, Steffen Foss

    2017-01-01

    ) workshop in Washington, D.C. and serves as the point of depature for this paper. Here we present the main outcomes by describing and defining the use of ATS for ENMs as well as discussing its future role in environmental risk science. We conclude that diversity in testing should be encouraged to avoid...... chemicals are challenged. Nonetheless, standardized whole organism animal testing is still considered the gold standard for environmental risk assessment. Advancing risk analysis of engineered nanomaterials (ENMs) through ATS was discussed in September 2014 at an international Society for Risk Analysis (SRA...... be utilized to skip uncertain environmental extrapolations and give rise to more accurate risk analysis....

  12. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    Science.gov (United States)

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power ( r  = 0.446, p  Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  13. Supporting Accurate Interpretation of Self-Administered Medical Test Results for Mobile Health: Assessment of Design, Demographics, and Health Condition.

    Science.gov (United States)

    Hohenstein, Jess C; Baumer, Eric Ps; Reynolds, Lindsay; Murnane, Elizabeth L; O'Dell, Dakota; Lee, Seoho; Guha, Shion; Qi, Yu; Rieger, Erin; Gay, Geri

    2018-02-28

    Technological advances in personal informatics allow people to track their own health in a variety of ways, representing a dramatic change in individuals' control of their own wellness. However, research regarding patient interpretation of traditional medical tests highlights the risks in making complex medical data available to a general audience. This study aimed to explore how people interpret medical test results, examined in the context of a mobile blood testing system developed to enable self-care and health management. In a preliminary investigation and main study, we presented 27 and 303 adults, respectively, with hypothetical results from several blood tests via one of the several mobile interface designs: a number representing the raw measurement of the tested biomarker, natural language text indicating whether the biomarker's level was low or high, or a one-dimensional chart illustrating this level along a low-healthy axis. We measured respondents' correctness in evaluating these results and their confidence in their interpretations. Participants also told us about any follow-up actions they would take based on the result and how they envisioned, generally, using our proposed personal health system. We find that a majority of participants (242/328, 73.8%) were accurate in their interpretations of their diagnostic results. However, 135 of 328 participants (41.1%) expressed uncertainty and confusion about their ability to correctly interpret these results. We also find that demographics and interface design can impact interpretation accuracy, including false confidence, which we define as a respondent having above average confidence despite interpreting a result inaccurately. Specifically, participants who saw a natural language design were the least likely (421.47 times, P=.02) to exhibit false confidence, and women who saw a graph design were less likely (8.67 times, P=.04) to have false confidence. On the other hand, false confidence was more likely

  14. Re-test reliability of gustatory testing and introduction of the sensitive Taste-Drop-Test

    DEFF Research Database (Denmark)

    Fjaeldstad, A; Niklassen, A; Fernandes, H

    2018-01-01

    . Testing gustatory function can be important for diagnostics and assessment of treatment effects. However, the gustatory tests applied are required to be both sensitive and reliable.In this study, we investigate the re-test validity of popular Taste Strips gustatory test for gustatory screening....... Furthermore, we introduce a new sensitive Taste-Drop-Test, which was found to be superior for detecting a more accurate measure of tastant sensitivity....

  15. Accurate Assessment of Computed Order Tracking

    Directory of Open Access Journals (Sweden)

    P.N. Saavedra

    2006-01-01

    Full Text Available Spectral vibration analysis using the Fourier transform is the most common technique for evaluating the mechanical condition of machinery working in stationary regimen. However, machinery operating in transient modes, such as variable speed equipment, generates spectra with distinct frequency content at each time, and the standard approach is not directly applicable for diagnostic. The "order tracking" technique is a suitable tool for analyzing variable speed machines. We have studied the computed order tracking (COT, and a new computed procedure is proposed for solving the indeterminate results generated by the traditional method at constant speed. The effect on the accuracy of the assumptions inherent in the COT was assessed using data from various simulations. The use of these simulations allowed us to determine the effect on the overall true accuracy of the method of different user-defined factors: the signal and tachometric pulse sampling frequency, the method of amplitude interpolation, and the number of tachometric pulses per revolution. Tests on real data measured on the main transmissions of a mining shovel were carried out, and we concluded that the new method is appropriate for the condition monitoring of this type of machine.

  16. Spectrally accurate contour dynamics

    International Nuclear Information System (INIS)

    Van Buskirk, R.D.; Marcus, P.S.

    1994-01-01

    We present an exponentially accurate boundary integral method for calculation the equilibria and dynamics of piece-wise constant distributions of potential vorticity. The method represents contours of potential vorticity as a spectral sum and solves the Biot-Savart equation for the velocity by spectrally evaluating a desingularized contour integral. We use the technique in both an initial-value code and a newton continuation method. Our methods are tested by comparing the numerical solutions with known analytic results, and it is shown that for the same amount of computational work our spectral methods are more accurate than other contour dynamics methods currently in use

  17. The Effects of Humor on Test Anxiety and Test Performance

    Science.gov (United States)

    Tali, Glenda

    2017-01-01

    Testing in an academic setting provokes anxiety in all students in higher education, particularly nursing students. When students experience high levels of anxiety, the resulting decline in test performance often does not represent an accurate assessment of students' academic achievement. This quantitative, experimental study examined the effects…

  18. Psychological Assessment of the Disabled.

    Science.gov (United States)

    Pool, Donald A.

    The paper examines issues, philosophy and guidelines for psychological assessment of the disabled. Focused on are: (1) adjustments in testing procedures and (2) applicability of standard norms with commonly used psychological test instruments for the assessment of ability, interest, and personality. The importance of accurate assessment for…

  19. Testing of a novel pin array guide for accurate three-dimensional glenoid component positioning.

    Science.gov (United States)

    Lewis, Gregory S; Stevens, Nicole M; Armstrong, April D

    2015-12-01

    A substantial challenge in total shoulder replacement is accurate positioning and alignment of the glenoid component. This challenge arises from limited intraoperative exposure and complex arthritic-driven deformity. We describe a novel pin array guide and method for patient-specific guiding of the glenoid central drill hole. We also experimentally tested the hypothesis that this method would reduce errors in version and inclination compared with 2 traditional methods. Polymer models of glenoids were created from computed tomography scans from 9 arthritic patients. Each 3-dimensional (3D) printed scapula was shrouded to simulate the operative situation. Three different methods for central drill alignment were tested, all with the target orientation of 5° retroversion and 0° inclination: no assistance, assistance by preoperative 3D imaging, and assistance by the pin array guide. Version and inclination errors of the drill line were compared. Version errors using the pin array guide (3° ± 2°) were significantly lower than version errors associated with no assistance (9° ± 7°) and preoperative 3D imaging (8° ± 6°). Inclination errors were also significantly lower using the pin array guide compared with no assistance. The new pin array guide substantially reduced errors in orientation of the central drill line. The guide method is patient specific but does not require rapid prototyping and instead uses adjustments to an array of pins based on automated software calculations. This method may ultimately provide a cost-effective solution enabling surgeons to obtain accurate orientation of the glenoid. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Towards Accurate Modelling of Galaxy Clustering on Small Scales: Testing the Standard ΛCDM + Halo Model

    Science.gov (United States)

    Sinha, Manodeep; Berlind, Andreas A.; McBride, Cameron K.; Scoccimarro, Roman; Piscionere, Jennifer A.; Wibking, Benjamin D.

    2018-04-01

    Interpreting the small-scale clustering of galaxies with halo models can elucidate the connection between galaxies and dark matter halos. Unfortunately, the modelling is typically not sufficiently accurate for ruling out models statistically. It is thus difficult to use the information encoded in small scales to test cosmological models or probe subtle features of the galaxy-halo connection. In this paper, we attempt to push halo modelling into the "accurate" regime with a fully numerical mock-based methodology and careful treatment of statistical and systematic errors. With our forward-modelling approach, we can incorporate clustering statistics beyond the traditional two-point statistics. We use this modelling methodology to test the standard ΛCDM + halo model against the clustering of SDSS DR7 galaxies. Specifically, we use the projected correlation function, group multiplicity function and galaxy number density as constraints. We find that while the model fits each statistic separately, it struggles to fit them simultaneously. Adding group statistics leads to a more stringent test of the model and significantly tighter constraints on model parameters. We explore the impact of varying the adopted halo definition and cosmological model and find that changing the cosmology makes a significant difference. The most successful model we tried (Planck cosmology with Mvir halos) matches the clustering of low luminosity galaxies, but exhibits a 2.3σ tension with the clustering of luminous galaxies, thus providing evidence that the "standard" halo model needs to be extended. This work opens the door to adding interesting freedom to the halo model and including additional clustering statistics as constraints.

  1. Turning the Page on Pen-and-Paper Questionnaires: Combining Ecological Momentary Assessment and Computer Adaptive Testing to Transform Psychological Assessment in the 21st Century.

    Science.gov (United States)

    Gibbons, Chris J

    2016-01-01

    The current paper describes new opportunities for patient-centred assessment methods which have come about by the increased adoption of affordable smart technologies in biopsychosocial research and medical care. In this commentary, we review modern assessment methods including item response theory (IRT), computer adaptive testing (CAT), and ecological momentary assessment (EMA) and explain how these methods may be combined to improve psychological assessment. We demonstrate both how a 'naïve' selection of a small group of items in an EMA can lead to unacceptably unreliable assessments and how IRT can provide detailed information on the individual information that each item gives thus allowing short form assessments to be selected with acceptable reliability. The combination of CAT and IRT can ensure assessments are precise, efficient, and well targeted to the individual; allowing EMAs to be both brief and accurate.

  2. An Assessment of IELTS Speaking Test

    Science.gov (United States)

    Karim, Shahzad; Haq, Naushaba

    2014-01-01

    The present study focused on assessing the speaking test of IELTS. The assessment discussed both positive aspects and weaknesses in IELTS speaking module. The researchers had also suggested some possible measures for the improvement in IELTS speaking test and increasing its validity and reliability. The researchers had analysed and assessed IELTS…

  3. Quantitative assessment of the BETHSY 6.9c test simulation

    International Nuclear Information System (INIS)

    Hrvatin, S.; Prosek, A.

    2000-01-01

    In the field of nuclear engineering, complex thermal-hydraulic computer codes are used to simulate and predict various transients in nuclear power plants. These computer codes are validated for overall system simulation by using experimental results, obtained on the integral test facilities. A post-test calculation of BETHSY 6.9c test with the RELAP5/MOD3.2 computer code has been performed in order to improve the input model in the future. The qualitative comparison of the results showed that most of the relevant parameters are predicted reasonably well. The quantitative assessment of the results was performed using the so-called Fast Fourier Transform Based Methodology. The FFTBM delineates and quantifies differences between calculated and experimental parameters in the frequency domain. The analysis showed that the the code calculations yield acceptable results. However, the primary pressure acceptability criterion is not fulfilled. This indicates that primary pressure calculation at low pressures is less accurate than at typical transient conditions. In general, it can be concluded that the RELAP5/MOD3.2 computer code can be used to analyze midloop operation at low power and pressure conditions. (author)

  4. Is self-assessment of medical abortion using a low-sensitivity pregnancy test combined with a checklist and phone text messages feasible in South African primary healthcare settings? A randomized trial.

    Directory of Open Access Journals (Sweden)

    Deborah Constant

    Full Text Available To evaluate feasibility of self-assessment of medical abortion outcome using a low-sensitivity urine pregnancy test, checklist and text messages. The study assessed whether accurate self-assessment required a demonstration of the low-sensitivity urine pregnancy test or if verbal instructions suffice.This non-inferiority trial enrolled 525 adult women from six public sector abortion clinics. Eligible women were undergoing medical abortion at gestations within 63 days. Consenting women completed a baseline interview, received standard care with mifepristone and home-administration of misoprostol. All were given a low-sensitivity urine pregnancy test and checklist for use 14 days later, sent text reminders, and asked to attend in-clinic follow-up after two weeks. Women were randomly assigned 1:1 to an instruction-only group (n = 262; issued with pre-scripted instructions on the low-sensitivity pregnancy test, or a demonstration group (n = 263; performed practice tests guided by lay health workers. The primary outcome was accurate self-assessment of incomplete abortion, defined as needing additional misoprostol or vacuum aspiration. Analysis was by intention to treat and a non-inferiority margin was set to six percentage points. Women's acceptability of their abortion procedure and preferences for follow-up were also assessed.Follow-up was 81% for abortion outcome, confirmed in-clinic at two weeks or self-reported within six months. Non-inferiority of instruction-only to a demonstration was inconclusive for accurate self-assessment (risk difference for instruction-only -demonstration: -2.5%; 95%CI: -9% to 4%. Comparing instruction-only to demonstration groups, 99% and 100% found the pregnancy test easy to do; and 91% and 93% respectively chose the pregnancy test, checklist and text messages for abortion outcome assessment in the future.Routine self-assessment using a low-sensitivity pregnancy test, checklist and text messages is feasible and

  5. Is self-assessment of medical abortion using a low-sensitivity pregnancy test combined with a checklist and phone text messages feasible in South African primary healthcare settings? A randomized trial.

    Science.gov (United States)

    Constant, Deborah; Harries, Jane; Daskilewicz, Kristen; Myer, Landon; Gemzell-Danielsson, Kristina

    2017-01-01

    To evaluate feasibility of self-assessment of medical abortion outcome using a low-sensitivity urine pregnancy test, checklist and text messages. The study assessed whether accurate self-assessment required a demonstration of the low-sensitivity urine pregnancy test or if verbal instructions suffice. This non-inferiority trial enrolled 525 adult women from six public sector abortion clinics. Eligible women were undergoing medical abortion at gestations within 63 days. Consenting women completed a baseline interview, received standard care with mifepristone and home-administration of misoprostol. All were given a low-sensitivity urine pregnancy test and checklist for use 14 days later, sent text reminders, and asked to attend in-clinic follow-up after two weeks. Women were randomly assigned 1:1 to an instruction-only group (n = 262; issued with pre-scripted instructions on the low-sensitivity pregnancy test), or a demonstration group (n = 263; performed practice tests guided by lay health workers). The primary outcome was accurate self-assessment of incomplete abortion, defined as needing additional misoprostol or vacuum aspiration. Analysis was by intention to treat and a non-inferiority margin was set to six percentage points. Women's acceptability of their abortion procedure and preferences for follow-up were also assessed. Follow-up was 81% for abortion outcome, confirmed in-clinic at two weeks or self-reported within six months. Non-inferiority of instruction-only to a demonstration was inconclusive for accurate self-assessment (risk difference for instruction-only -demonstration: -2.5%; 95%CI: -9% to 4%). Comparing instruction-only to demonstration groups, 99% and 100% found the pregnancy test easy to do; and 91% and 93% respectively chose the pregnancy test, checklist and text messages for abortion outcome assessment in the future. Routine self-assessment using a low-sensitivity pregnancy test, checklist and text messages is feasible and preferred by women

  6. Functional Assessment of Battery Management System Tested on Hardware-in-the-Loop Simulator

    DEFF Research Database (Denmark)

    Kalogiannis, Theodoros; Stroe, Daniel-Ioan; Swierczynski, Maciej Jozef

    2017-01-01

    . The BMS under test is interacting in real-time with the emulated battery pack and several of its functions such as current, voltage and State of Charge (SOC) estimation are evaluated. Also, passive balancing experiments are conducted during charging in order to assess different balancing settings...... of the BMS as far as their respective balancing times and deviations in SOC are concerned. Finally, the energy efficiency of the BMS is accurately measured which, depending on the requirements, can achieve more than 99% of efficiency. In general, it is demonstrated that the HIL setup can provide...... representative outcomes at minimum resources and time requirements....

  7. Assessment of Direct-to-Consumer Genetic Testing Policy in Korea Based on Consumer Preference.

    Science.gov (United States)

    Jeong, Gicheol

    2017-01-01

    In June 2016, Korea permitted direct-to-consumer genetic testing (DTC-GT) on 42 genes. However, both the market and industry have not yet been fully activated. Considering the aforementioned context, this study provides important insights. The Korean DTC-GT policy assessment is based on consumer preference analysis using a discrete choice experiment. In August 2016, a web-based survey was conducted to collect data from 1,200 respondents. The estimation results show that consumers prefer a DTC-GT product that is cheap, tests various items or genes, offers accurate test results, and guarantees the confidentiality of all information. However, consumers are not entirely satisfied by current DTC-GT products due to the existence of insufficient and/or inadequate policies. First, the permitted testing of 42 genes is insufficient to satisfy consumers' curiosity regarding their genes. Second, the accuracy of the DTC-GT products has not been fully verified, assessed, and communicated to consumers. Finally, regulatory loopholes that allow information leaks in the DTC-GT process can occur. These findings imply that DTC-GT requires an improvement in government policy-making criteria and the implementation of practical measures to guarantee test accuracy and genetic information. © 2017 S. Karger AG, Basel.

  8. Accurate Classification of Chronic Migraine via Brain Magnetic Resonance Imaging

    Science.gov (United States)

    Schwedt, Todd J.; Chong, Catherine D.; Wu, Teresa; Gaw, Nathan; Fu, Yinlin; Li, Jing

    2015-01-01

    Background The International Classification of Headache Disorders provides criteria for the diagnosis and subclassification of migraine. Since there is no objective gold standard by which to test these diagnostic criteria, the criteria are based on the consensus opinion of content experts. Accurate migraine classifiers consisting of brain structural measures could serve as an objective gold standard by which to test and revise diagnostic criteria. The objectives of this study were to utilize magnetic resonance imaging measures of brain structure for constructing classifiers: 1) that accurately identify individuals as having chronic vs. episodic migraine vs. being a healthy control; and 2) that test the currently used threshold of 15 headache days/month for differentiating chronic migraine from episodic migraine. Methods Study participants underwent magnetic resonance imaging for determination of regional cortical thickness, cortical surface area, and volume. Principal components analysis combined structural measurements into principal components accounting for 85% of variability in brain structure. Models consisting of these principal components were developed to achieve the classification objectives. Ten-fold cross validation assessed classification accuracy within each of the ten runs, with data from 90% of participants randomly selected for classifier development and data from the remaining 10% of participants used to test classification performance. Headache frequency thresholds ranging from 5–15 headache days/month were evaluated to determine the threshold allowing for the most accurate subclassification of individuals into lower and higher frequency subgroups. Results Participants were 66 migraineurs and 54 healthy controls, 75.8% female, with an average age of 36 +/− 11 years. Average classifier accuracies were: a) 68% for migraine (episodic + chronic) vs. healthy controls; b) 67.2% for episodic migraine vs. healthy controls; c) 86.3% for chronic

  9. Non-destructive testing for plant life assessment

    International Nuclear Information System (INIS)

    2005-01-01

    The International Atomic Energy Agency (IAEA) is promoting industrial applications of nondestructive testing (NDT) technology, which includes radiography testing (RT) and related methods, to assure safety and reliability of operation of industrial facilities and processes. NDT technology is essentially needed for improvement of the quality of industrial products, safe performance of equipment and plants, including safety of metallic and concrete structures and constructions. The IAEA is playing an important role in promoting the NDT use and technology support to Member States, in harmonisation for training and certification of NDT personnel, and in establishing national accreditation and certifying bodies. All these efforts have led to a stage of maturity and self sufficiency in numerous countries especially in the field of training and certification of personnel, and in provision of services to industries. This has had a positive impact on the improvement of the quality of industrial goods and services. NDT methods are primarily used for detection, location and sizing of surface and internal defects (in welds, castings, forging, composite materials, concrete and many more). Various NDT methods are applied for preventive maintenance (aircraft, bridge), for the inspection of raw materials, half-finished and finished products, for in-service-inspection and for plant life assessment studies. NDT is essential for quality control of the facilities and products, and for fitness - for purpose assessment (so-called plant life assessment). NDT evaluates remaining operation life of plant components (processing lines, pipes, vessels) providing an accurate diagnosis that allows predicting extended life operation beyond design life. Status and trends on the NDT for plant life assessment have been discussed in many IAEA meetings related with NDT development, training and education. Experts have largely demonstrated that, using NDT methods, a comprehensive assessment of the life

  10. Daily FOUR score assessment provides accurate prognosis of long-term outcome in out-of-hospital cardiac arrest.

    Science.gov (United States)

    Weiss, N; Venot, M; Verdonk, F; Chardon, A; Le Guennec, L; Llerena, M C; Raimbourg, Q; Taldir, G; Luque, Y; Fagon, J-Y; Guerot, E; Diehl, J-L

    2015-05-01

    The accurate prediction of outcome after out-of-hospital cardiac arrest (OHCA) is of major importance. The recently described Full Outline of UnResponsiveness (FOUR) is well adapted to mechanically ventilated patients and does not depend on verbal response. To evaluate the ability of FOUR assessed by intensivists to accurately predict outcome in OHCA. We prospectively identified patients admitted for OHCA with a Glasgow Coma Scale below 8. Neurological assessment was performed daily. Outcome was evaluated at 6 months using Glasgow-Pittsburgh Cerebral Performance Categories (GP-CPC). Eighty-five patients were included. At 6 months, 19 patients (22%) had a favorable outcome, GP-CPC 1-2, and 66 (78%) had an unfavorable outcome, GP-CPC 3-5. Compared to both brainstem responses at day 3 and evolution of Glasgow Coma Scale, evolution of FOUR score over the three first days was able to predict unfavorable outcome more precisely. Thus, absence of improvement or worsening from day 1 to day 3 of FOUR had 0.88 (0.79-0.97) specificity, 0.71 (0.66-0.76) sensitivity, 0.94 (0.84-1.00) PPV and 0.54 (0.49-0.59) NPV to predict unfavorable outcome. Similarly, the brainstem response of FOUR score at 0 evaluated at day 3 had 0.94 (0.89-0.99) specificity, 0.60 (0.50-0.70) sensitivity, 0.96 (0.92-1.00) PPV and 0.47 (0.37-0.57) NPV to predict unfavorable outcome. The absence of improvement or worsening from day 1 to day 3 of FOUR evaluated by intensivists provides an accurate prognosis of poor neurological outcome in OHCA. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. How Accurately Can the Google Web Speech API Recognize and Transcribe Japanese L2 English Learners' Oral Production?

    Science.gov (United States)

    Ashwell, Tim; Elam, Jesse R.

    2017-01-01

    The ultimate aim of our research project was to use the Google Web Speech API to automate scoring of elicited imitation (EI) tests. However, in order to achieve this goal, we had to take a number of preparatory steps. We needed to assess how accurate this speech recognition tool is in recognizing native speakers' production of the test items; we…

  12. Accurate forced-choice recognition without awareness of memory retrieval

    OpenAIRE

    Voss, Joel L.; Baym, Carol L.; Paller, Ken A.

    2008-01-01

    Recognition confidence and the explicit awareness of memory retrieval commonly accompany accurate responding in recognition tests. Memory performance in recognition tests is widely assumed to measure explicit memory, but the generality of this assumption is questionable. Indeed, whether recognition in nonhumans is always supported by explicit memory is highly controversial. Here we identified circumstances wherein highly accurate recognition was unaccompanied by hallmark features of explicit ...

  13. The importance of accurate meteorological input fields and accurate planetary boundary layer parameterizations, tested against ETEX-1

    International Nuclear Information System (INIS)

    Brandt, J.; Ebel, A.; Elbern, H.; Jakobs, H.; Memmesheimer, M.; Mikkelsen, T.; Thykier-Nielsen, S.; Zlatev, Z.

    1997-01-01

    Atmospheric transport of air pollutants is, in principle, a well understood process. If information about the state of the atmosphere is given in all details (infinitely accurate information about wind speed, etc.) and infinitely fast computers are available then the advection equation could in principle be solved exactly. This is, however, not the case: discretization of the equations and input data introduces some uncertainties and errors in the results. Therefore many different issues have to be carefully studied in order to diminish these uncertainties and to develop an accurate transport model. Some of these are e.g. the numerical treatment of the transport equation, accuracy of the mean meteorological input fields and parameterizations of sub-grid scale phenomena (as e.g. parameterizations of the 2 nd and higher order turbulence terms in order to reach closure in the perturbation equation). A tracer model for studying transport and dispersion of air pollution caused by a single but strong source is under development. The model simulations from the first ETEX release illustrate the differences caused by using various analyzed fields directly in the tracer model or using a meteorological driver. Also different parameterizations of the mixing height and the vertical exchange are compared. (author)

  14. Using digital photography in a clinical setting: a valid, accurate, and applicable method to assess food intake.

    Science.gov (United States)

    Winzer, Eva; Luger, Maria; Schindler, Karin

    2018-06-01

    Regular monitoring of food intake is hardly integrated in clinical routine. Therefore, the aim was to examine the validity, accuracy, and applicability of an appropriate and also quick and easy-to-use tool for recording food intake in a clinical setting. Two digital photography methods, the postMeal method with a picture after the meal, the pre-postMeal method with a picture before and after the meal, and the visual estimation method (plate diagram; PD) were compared against the reference method (weighed food records; WFR). A total of 420 dishes from lunch (7 weeks) were estimated with both photography methods and the visual method. Validity, applicability, accuracy, and precision of the estimation methods, and additionally food waste, macronutrient composition, and energy content were examined. Tests of validity revealed stronger correlations for photography methods (postMeal: r = 0.971, p < 0.001; pre-postMeal: r = 0.995, p < 0.001) compared to the visual estimation method (r = 0.810; p < 0.001). The pre-postMeal method showed smaller variability (bias < 1 g) and also smaller overestimation and underestimation. This method accurately and precisely estimated portion sizes in all food items. Furthermore, the total food waste was 22% for lunch over the study period. The highest food waste was observed in salads and the lowest in desserts. The pre-postMeal digital photography method is valid, accurate, and applicable in monitoring food intake in clinical setting, which enables a quantitative and qualitative dietary assessment. Thus, nutritional care might be initiated earlier. This method might be also advantageous for quantitative and qualitative evaluation of food waste, with a resultantly reduction in costs.

  15. An accurate and efficient identification of children with psychosocial problems by means of computerized adaptive testing

    Directory of Open Access Journals (Sweden)

    Reijneveld Symen A

    2011-08-01

    Full Text Available Abstract Background Questionnaires used by health services to identify children with psychosocial problems are often rather short. The psychometric properties of such short questionnaires are mostly less than needed for an accurate distinction between children with and without problems. We aimed to assess whether a short Computerized Adaptive Test (CAT can overcome the weaknesses of short written questionnaires when identifying children with psychosocial problems. Method We used a Dutch national data set obtained from parents of children invited for a routine health examination by Preventive Child Healthcare with 205 items on behavioral and emotional problems (n = 2,041, response 84%. In a random subsample we determined which items met the requirements of an Item Response Theory (IRT model to a sufficient degree. Using those items, item parameters necessary for a CAT were calculated and a cut-off point was defined. In the remaining subsample we determined the validity and efficiency of a Computerized Adaptive Test using simulation techniques, with current treatment status and a clinical score on the Total Problem Scale (TPS of the Child Behavior Checklist as criteria. Results Out of 205 items available 190 sufficiently met the criteria of the underlying IRT model. For 90% of the children a score above or below cut-off point could be determined with 95% accuracy. The mean number of items needed to achieve this was 12. Sensitivity and specificity with the TPS as a criterion were 0.89 and 0.91, respectively. Conclusion An IRT-based CAT is a very promising option for the identification of psychosocial problems in children, as it can lead to an efficient, yet high-quality identification. The results of our simulation study need to be replicated in a real-life administration of this CAT.

  16. How accurate are adolescents in portion-size estimation using the computer tool young adolescents' nutrition assessment on computer (YANA-C)?

    OpenAIRE

    Vereecken, Carine; Dohogne, Sophie; Covents, Marc; Maes, Lea

    2010-01-01

    Computer-administered questionnaires have received increased attention for large-scale population research on nutrition. In Belgium-Flanders, Young Adolescents' Nutrition Assessment on Computer (YANA-C) has been developed. In this tool, standardised photographs are available to assist in portion-size estimation. The purpose of the present study is to assess how accurate adolescents are in estimating portion sizes of food using YANA-C. A convenience sample, aged 11-17 years, estimated the amou...

  17. Revising the ADAS-cog for a more accurate assessment of cognitive impairment.

    Science.gov (United States)

    Wouters, Hans; van Gool, Willem A; Schmand, Ben; Lindeboom, Robert

    2008-01-01

    To examine whether it is appropriate to sum the cognitive part of the Alzheimer Disease Assessment Scale (ADAS-cog) items to assess cognitive impairment. This assumes items to have (1) equal measurement precision and (2) hierarchically ordered categories. Rasch analysis on the basis of pooled data from 3 Randomized Controlled Trials was used to examine these assumptions and to estimate each patient's level of impairment. Analyses were replicated in an independent sample. The original ADAS-cog scoring did not fit the Rasch Model and did not reliably distinguish between impairment levels. Patients with equal test scores had different impairment levels. Similarly, patients with different test scores could have the same impairment level. Revising the ADAS-cog by (1) weighting the items by their measurement precision and (2) collapsing nonhierarchical item categories resulted in good fit and a valid one to one correspondence between sum scores and estimated impairment levels. This revealed that equal differences in ADAS-cog scores did not reflect equal differences in impairment level along the test's score range. It is appropriate to summate the ADAS-cog items provided that the items are weighted and have their categories hierarchically ordered.

  18. An accurately controllable imitative stress corrosion cracking for electromagnetic nondestructive testing and evaluations

    International Nuclear Information System (INIS)

    Yusa, Noritaka; Uchimoto, Tetsuya; Takagi, Toshiyuki; Hashizume, Hidetoshi

    2012-01-01

    Highlights: ► We propose a method to simulate stress corrosion cracking. ► The method offers nondestructive signals similar to those of actual cracking. ► Visual and eddy current examinations validate the method. - Abstract: This study proposes a simple and cost-effective approach to fabricate an artificial flaw that is identical to stress corrosion cracking especially from the viewpoint of electromagnetic nondestructive evaluations. The key idea of the approach is to embed a partially-bonded region inside a material by bonding together surfaces that have grooves. The region is regarded as an area of uniform non-zero conductivity from an electromagnetic nondestructive point of view, and thus simulates the characteristics of stress corrosion cracking. Since the grooves are introduced using electro-discharge machining, one can control the profile of the imitative stress corrosion cracking accurately. After numerical simulation to evaluate the spatial resolution of conventional eddy current testing, six specimens made of type 316L austenitic stainless steel were fabricated on the basis of the results of the simulations. Visual and eddy current examinations were carried out to demonstrate that the artificial flaws well simulated the characteristics of actual stress corrosion cracking. Subsequent destructive test confirmed that the bonding did not change the depth profiles of the artificial flaw.

  19. A practical method for accurate quantification of large fault trees

    International Nuclear Information System (INIS)

    Choi, Jong Soo; Cho, Nam Zin

    2007-01-01

    This paper describes a practical method to accurately quantify top event probability and importance measures from incomplete minimal cut sets (MCS) of a large fault tree. The MCS-based fault tree method is extensively used in probabilistic safety assessments. Several sources of uncertainties exist in MCS-based fault tree analysis. The paper is focused on quantification of the following two sources of uncertainties: (1) the truncation neglecting low-probability cut sets and (2) the approximation in quantifying MCSs. The method proposed in this paper is based on a Monte Carlo simulation technique to estimate probability of the discarded MCSs and the sum of disjoint products (SDP) approach complemented by the correction factor approach (CFA). The method provides capability to accurately quantify the two uncertainties and estimate the top event probability and importance measures of large coherent fault trees. The proposed fault tree quantification method has been implemented in the CUTREE code package and is tested on the two example fault trees

  20. DNA barcode data accurately assign higher spider taxa

    Directory of Open Access Journals (Sweden)

    Jonathan A. Coddington

    2016-07-01

    Full Text Available The use of unique DNA sequences as a method for taxonomic identification is no longer fundamentally controversial, even though debate continues on the best markers, methods, and technology to use. Although both existing databanks such as GenBank and BOLD, as well as reference taxonomies, are imperfect, in best case scenarios “barcodes” (whether single or multiple, organelle or nuclear, loci clearly are an increasingly fast and inexpensive method of identification, especially as compared to manual identification of unknowns by increasingly rare expert taxonomists. Because most species on Earth are undescribed, a complete reference database at the species level is impractical in the near term. The question therefore arises whether unidentified species can, using DNA barcodes, be accurately assigned to more inclusive groups such as genera and families—taxonomic ranks of putatively monophyletic groups for which the global inventory is more complete and stable. We used a carefully chosen test library of CO1 sequences from 49 families, 313 genera, and 816 species of spiders to assess the accuracy of genus and family-level assignment. We used BLAST queries of each sequence against the entire library and got the top ten hits. The percent sequence identity was reported from these hits (PIdent, range 75–100%. Accurate assignment of higher taxa (PIdent above which errors totaled less than 5% occurred for genera at PIdent values >95 and families at PIdent values ≥ 91, suggesting these as heuristic thresholds for accurate generic and familial identifications in spiders. Accuracy of identification increases with numbers of species/genus and genera/family in the library; above five genera per family and fifteen species per genus all higher taxon assignments were correct. We propose that using percent sequence identity between conventional barcode sequences may be a feasible and reasonably accurate method to identify animals to family/genus. However

  1. Novel approach for assessing performance of PCR cyclers used for diagnostic testing

    DEFF Research Database (Denmark)

    Schoder, D.; Schmalwieser, A.; Schauberger, G.

    2005-01-01

    of thermal homogeneities became most evident at the denaturation level during the first 15 s. At the time point zero, the accurate cyclers showed temperature deviations of 0.5 to 1.5 degrees C, whereas less-accurate cyclers failed to reach the set temperature by 13 to 20 degrees C. Consequently, the two less......As part of a large international project for validation and standardization of PCR, the influence of thermocyclers on PCR was tested. Six brand-new, Peltier technology-driven 96-well thermocyclers were subjected to a novel and stringent in-tube (not block) physical testing. The temperature...

  2. Is Assessment of Femoral Head Perfusion During Modified Dunn for Unstable Slipped Capital Femoral Epiphysis an Accurate Indicator of Osteonecrosis?

    Science.gov (United States)

    Novais, Eduardo N; Sink, Ernest L; Kestel, Lauryn A; Carry, Patrick M; Abdo, João C M; Heare, Travis C

    2016-08-01

    The modified Dunn procedure, which is an open subcapital realignment through a surgical dislocation approach, has gained popularity for the treatment of unstable slipped capital femoral epiphysis (SCFE). Intraoperative monitoring of the femoral head perfusion has been recommended as a method of predicting osteonecrosis; however, the accuracy of this assessment has not been well documented. We asked (1) whether intraoperative assessment of femoral head perfusion would help identify hips at risk of developing osteonecrosis; (2) whether one of the four methods of assessment of femoral head perfusion is more accurate (highest area under the curve) at identifying hips at risk of osteonecrosis; and (3) whether specific clinical features would be associated with osteonecrosis occurrence after a modified Dunn procedure for unstable SCFE. Between 2007 and 2014, we performed 29 modified Dunn procedures for unstable SCFE (16 boys, 11 girls; median age, 13 years; range, 8-17 years); two were lost to followup before 1 year. During this period, six patients with unstable SCFE were treated by other procedures. All patients undergoing modified Dunn underwent assessment of epiphyseal perfusion by the presence of active bleeding and/or by intracranial pressure (ICP) monitoring. In the initial five patients perfusion was recorded once, either before dissection of the retinacular flap or after fixation by one of the two methods. In the remaining 22 patients (81%), perfusion was systematically assessed before dissection of the retinacular flap and after fixation by both methods. Minimum followup was 1 year (median, 2.5 years; range, 1-8 years) because osteonecrosis typically develops within the first year after surgery. Patients were assessed for osteonecrosis by the presence of femoral head collapse at radiographs obtained every 3 months during the first year after surgery. Seven (26%) of the 27 patients developed osteonecrosis. Measures of diagnostic accuracy including sensitivity

  3. Accelerated spike resampling for accurate multiple testing controls.

    Science.gov (United States)

    Harrison, Matthew T

    2013-02-01

    Controlling for multiple hypothesis tests using standard spike resampling techniques often requires prohibitive amounts of computation. Importance sampling techniques can be used to accelerate the computation. The general theory is presented, along with specific examples for testing differences across conditions using permutation tests and for testing pairwise synchrony and precise lagged-correlation between many simultaneously recorded spike trains using interval jitter.

  4. Test reactor risk assessment methodology

    International Nuclear Information System (INIS)

    Jennings, R.H.; Rawlins, J.K.; Stewart, M.E.

    1976-04-01

    A methodology has been developed for the identification of accident initiating events and the fault modeling of systems, including common mode identification, as these methods are applied in overall test reactor risk assessment. The methods are exemplified by a determination of risks to a loss of primary coolant flow in the Engineering Test Reactor

  5. Dynamic and accurate assessment of acetaminophen-induced hepatotoxicity by integrated photoacoustic imaging and mechanistic biomarkers in vivo.

    Science.gov (United States)

    Brillant, Nathalie; Elmasry, Mohamed; Burton, Neal C; Rodriguez, Josep Monne; Sharkey, Jack W; Fenwick, Stephen; Poptani, Harish; Kitteringham, Neil R; Goldring, Christopher E; Kipar, Anja; Park, B Kevin; Antoine, Daniel J

    2017-10-01

    The prediction and understanding of acetaminophen (APAP)-induced liver injury (APAP-ILI) and the response to therapeutic interventions is complex. This is due in part to sensitivity and specificity limitations of currently used assessment techniques. Here we sought to determine the utility of integrating translational non-invasive photoacoustic imaging of liver function with mechanistic circulating biomarkers of hepatotoxicity with histological assessment to facilitate the more accurate and precise characterization of APAP-ILI and the efficacy of therapeutic intervention. Perturbation of liver function and cellular viability was assessed in C57BL/6J male mice by Indocyanine green (ICG) clearance (Multispectral Optoacoustic Tomography (MSOT)) and by measurement of mechanistic (miR-122, HMGB1) and established (ALT, bilirubin) circulating biomarkers in response to the acetaminophen and its treatment with acetylcysteine (NAC) in vivo. We utilised a 60% partial hepatectomy model as a situation of defined hepatic functional mass loss to compared acetaminophen-induced changes to. Integration of these mechanistic markers correlated with histological features of APAP hepatotoxicity in a time-dependent manner. They accurately reflected the onset and recovery from hepatotoxicity compared to traditional biomarkers and also reported the efficacy of NAC with high sensitivity. ICG clearance kinetics correlated with histological scores for acute liver damage for APAP (i.e. 3h timepoint; r=0.90, P<0.0001) and elevations in both of the mechanistic biomarkers, miR-122 (e.g. 6h timepoint; r=0.70, P=0.005) and HMGB1 (e.g. 6h timepoint; r=0.56, P=0.04). For the first time we report the utility of this non-invasive longitudinal imaging approach to provide direct visualisation of the liver function coupled with mechanistic biomarkers, in the same animal, allowing the investigation of the toxicological and pharmacological aspects of APAP-ILI and hepatic regeneration. Copyright © 2017

  6. A Single Test Combining Blood Markers and Elastography is More Accurate Than Other Fibrosis Tests in the Main Causes of Chronic Liver Diseases.

    Science.gov (United States)

    Ducancelle, Alexandra; Leroy, Vincent; Vergniol, Julien; Sturm, Nathalie; Le Bail, Brigitte; Zarski, Jean Pierre; Nguyen Khac, Eric; Salmon, Dominique; de Ledinghen, Victor; Calès, Paul

    2017-08-01

    International guidelines suggest combining a blood test and liver stiffness measurement (LSM) to stage liver fibrosis in chronic hepatitis C (CHC) and non-alcoholic fatty liver disease (NAFLD). Therefore, we compared the accuracies of these tests between the main etiologies of chronic liver diseases. Overall, 1968 patients were included in 5 etiologies: CHC: 698, chronic hepatitis B: 152, human immunodeficiency virus/CHC: 628, NAFLD: 225, and alcoholic liver disease (ALD): 265. Sixteen tests [13 blood tests, LSM (Fibroscan), 2 combined: FibroMeters] were evaluated. References were Metavir staging and CHC etiology. Accuracy was evaluated mainly with the Obuchowski index (OI) and accessorily with area under the receiver operating characteristics (F≥2, F≥3, cirrhosis). OIs in CHC were: FibroMeters: 0.812, FibroMeters: 0.785 to 0.797, Fibrotest: 0.762, CirrhoMeters: 0.756 to 0.771, LSM: 0.754, Hepascore: 0.752, FibroMeter: 0.750, aspartate aminotransferase platelet ratio index: 0.742, Fib-4: 0.741. In other etiologies, most tests had nonsignificant changes in OIs. In NAFLD, CHC-specific tests were more accurate than NAFLD-specific tests. The combined FibroMeters had significantly higher accuracy than their 2 constitutive tests (FibroMeters and LSM) in at least 1 diagnostic target in all etiologies, except in ALD where LSM had the highest OI, and in 3 diagnostic targets (OIs and 2 area under the receiver operating characteristics) in CHC and NAFLD. Some tests developed in CHC outperformed other tests in their specific etiologies. Tests combining blood markers and LSM outperformed single tests, validating recent guidelines and extending them to main etiologies. Noninvasive fibrosis evaluation can thus be simplified in the main etiologies by using a unique test: either LSM alone, especially in ALD, or preferably combined to blood markers.

  7. Constructing Aligned Assessments Using Automated Test Construction

    Science.gov (United States)

    Porter, Andrew; Polikoff, Morgan S.; Barghaus, Katherine M.; Yang, Rui

    2013-01-01

    We describe an innovative automated test construction algorithm for building aligned achievement tests. By incorporating the algorithm into the test construction process, along with other test construction procedures for building reliable and unbiased assessments, the result is much more valid tests than result from current test construction…

  8. Assessment on separate effect tests

    International Nuclear Information System (INIS)

    Bernard, M.; Kukita, Y.; Renault, C.

    1985-01-01

    In the general frame of Cathare assessment this operation is aimed to qualify the set of constitutive laws by reconstitution of experimental tests. The experimental tests are selected following 2 objectives: to be able to qualify separately (as far as possible) the constitutive laws, and, to cover the entire parameter range which is of interest for safety studies. This selection has led to a set of 135 separate effect tests taken from 15 experimental facilities and which can be arranged in 3 main categories: Adiabatic flow tests, without significant external heat exchange; non adiabatic flow tests, in which external heating or cooling is applied to the test section but not being driven by wall heat exchange; and, heat transfer tests, in which wall heat transfer plays the dominant role

  9. A Machine Learned Classifier That Uses Gene Expression Data to Accurately Predict Estrogen Receptor Status

    Science.gov (United States)

    Bastani, Meysam; Vos, Larissa; Asgarian, Nasimeh; Deschenes, Jean; Graham, Kathryn; Mackey, John; Greiner, Russell

    2013-01-01

    Background Selecting the appropriate treatment for breast cancer requires accurately determining the estrogen receptor (ER) status of the tumor. However, the standard for determining this status, immunohistochemical analysis of formalin-fixed paraffin embedded samples, suffers from numerous technical and reproducibility issues. Assessment of ER-status based on RNA expression can provide more objective, quantitative and reproducible test results. Methods To learn a parsimonious RNA-based classifier of hormone receptor status, we applied a machine learning tool to a training dataset of gene expression microarray data obtained from 176 frozen breast tumors, whose ER-status was determined by applying ASCO-CAP guidelines to standardized immunohistochemical testing of formalin fixed tumor. Results This produced a three-gene classifier that can predict the ER-status of a novel tumor, with a cross-validation accuracy of 93.17±2.44%. When applied to an independent validation set and to four other public databases, some on different platforms, this classifier obtained over 90% accuracy in each. In addition, we found that this prediction rule separated the patients' recurrence-free survival curves with a hazard ratio lower than the one based on the IHC analysis of ER-status. Conclusions Our efficient and parsimonious classifier lends itself to high throughput, highly accurate and low-cost RNA-based assessments of ER-status, suitable for routine high-throughput clinical use. This analytic method provides a proof-of-principle that may be applicable to developing effective RNA-based tests for other biomarkers and conditions. PMID:24312637

  10. A fully automated Drosophila olfactory classical conditioning and testing system for behavioral learning and memory assessment.

    Science.gov (United States)

    Jiang, Hui; Hanna, Eriny; Gatto, Cheryl L; Page, Terry L; Bhuva, Bharat; Broadie, Kendal

    2016-03-01

    Aversive olfactory classical conditioning has been the standard method to assess Drosophila learning and memory behavior for decades, yet training and testing are conducted manually under exceedingly labor-intensive conditions. To overcome this severe limitation, a fully automated, inexpensive system has been developed, which allows accurate and efficient Pavlovian associative learning/memory analyses for high-throughput pharmacological and genetic studies. The automated system employs a linear actuator coupled to an odorant T-maze with airflow-mediated transfer of animals between training and testing stages. Odorant, airflow and electrical shock delivery are automatically administered and monitored during training trials. Control software allows operator-input variables to define parameters of Drosophila learning, short-term memory and long-term memory assays. The approach allows accurate learning/memory determinations with operational fail-safes. Automated learning indices (immediately post-training) and memory indices (after 24h) are comparable to traditional manual experiments, while minimizing experimenter involvement. The automated system provides vast improvements over labor-intensive manual approaches with no experimenter involvement required during either training or testing phases. It provides quality control tracking of airflow rates, odorant delivery and electrical shock treatments, and an expanded platform for high-throughput studies of combinational drug tests and genetic screens. The design uses inexpensive hardware and software for a total cost of ∼$500US, making it affordable to a wide range of investigators. This study demonstrates the design, construction and testing of a fully automated Drosophila olfactory classical association apparatus to provide low-labor, high-fidelity, quality-monitored, high-throughput and inexpensive learning and memory behavioral assays. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Rapid and accurate evaluation of the quality of commercial organic fertilizers using near infrared spectroscopy.

    Directory of Open Access Journals (Sweden)

    Chang Wang

    Full Text Available The composting industry has been growing rapidly in China because of a boom in the animal industry. Therefore, a rapid and accurate assessment of the quality of commercial organic fertilizers is of the utmost importance. In this study, a novel technique that combines near infrared (NIR spectroscopy with partial least squares (PLS analysis is developed for rapidly and accurately assessing commercial organic fertilizers quality. A total of 104 commercial organic fertilizers were collected from full-scale compost factories in Jiangsu Province, east China. In general, the NIR-PLS technique showed accurate predictions of the total organic matter, water soluble organic nitrogen, pH, and germination index; less accurate results of the moisture, total nitrogen, and electrical conductivity; and the least accurate results for water soluble organic carbon. Our results suggested the combined NIR-PLS technique could be applied as a valuable tool to rapidly and accurately assess the quality of commercial organic fertilizers.

  12. Rapid and accurate evaluation of the quality of commercial organic fertilizers using near infrared spectroscopy.

    Science.gov (United States)

    Wang, Chang; Huang, Chichao; Qian, Jian; Xiao, Jian; Li, Huan; Wen, Yongli; He, Xinhua; Ran, Wei; Shen, Qirong; Yu, Guanghui

    2014-01-01

    The composting industry has been growing rapidly in China because of a boom in the animal industry. Therefore, a rapid and accurate assessment of the quality of commercial organic fertilizers is of the utmost importance. In this study, a novel technique that combines near infrared (NIR) spectroscopy with partial least squares (PLS) analysis is developed for rapidly and accurately assessing commercial organic fertilizers quality. A total of 104 commercial organic fertilizers were collected from full-scale compost factories in Jiangsu Province, east China. In general, the NIR-PLS technique showed accurate predictions of the total organic matter, water soluble organic nitrogen, pH, and germination index; less accurate results of the moisture, total nitrogen, and electrical conductivity; and the least accurate results for water soluble organic carbon. Our results suggested the combined NIR-PLS technique could be applied as a valuable tool to rapidly and accurately assess the quality of commercial organic fertilizers.

  13. Reproducibility of an objective four-choice canine vision testing technique that assesses vision at differing light intensities.

    Science.gov (United States)

    Annear, Matthew J; Gornik, Kara R; Venturi, Francesca L; Hauptman, Joe G; Bartoe, Joshua T; Petersen-Jones, Simon M

    2013-09-01

    The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs.   Four 11-month-old RPE65-deficient dogs. Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time. © 2012 American College of Veterinary Ophthalmologists.

  14. High prevalence of normal tests assessing hypercortisolism in subjects with mild and episodic Cushing's syndrome suggests that the paradigm for diagnosis and exclusion of Cushing's syndrome requires multiple testing.

    Science.gov (United States)

    Friedman, T C; Ghods, D E; Shahinian, H K; Zachery, L; Shayesteh, N; Seasholtz, S; Zuckerbraun, E; Lee, M L; McCutcheon, I E

    2010-11-01

    Many Endocrinologists believe that a single determination of eucortisolism or a single demonstration of appropriate suppression to dexamethasone excluded Cushing's syndrome, except in what was previously thought to be the rare patient with episodic or periodic Cushing's syndrome. We hypothesize that episodic Cushing's syndrome is relatively common and a single test assessing hypercortisolism may not be sufficient to accurately rule out or diagnose Cushing's syndrome and retrospectively examined the number of normal and abnormal tests assessing hypercortisolism performed on multiple occasions in 66 patients found to have mild and/or episodic Cushing's syndrome compared to a similar group of 54 patients evaluated for, but determined not to have Cushing's syndrome. We found that 65 of the 66 patients with Cushing's syndrome had at least one normal test of cortisol status and most patients had several normal tests. The probability of having Cushing's syndrome when one test was negative was 92% for 23:00 h salivary cortisol, 88% for 24-h UFC, 86% for 24-h 17OHS, and 54% for nighttime plasma cortisol. These results demonstrated that episodic hypercortisolism is highly prevalent in subjects with mild Cushing's syndrome and no single test was effective in conclusively diagnosing or excluding the condition. Rather, the paradigm for the diagnosis should be a careful history and physical examination and in those patients in whom mild Cushing's syndrome/disease is strongly suspected, multiple tests assessing hypercortisolism should be performed on subsequent occasions, especially when the patient is experiencing signs and symptoms of short-term hypercortisolism. © Georg Thieme Verlag KG Stuttgart · New York.

  15. The GP tests of competence assessment: which part best predicts fitness to practise decisions?

    Science.gov (United States)

    Jayaweera, Hirosha Keshani; Potts, Henry W W; Keshwani, Karim; Valerio, Chris; Baker, Magdalen; Mehdizadeh, Leila; Sturrock, Alison

    2018-01-02

    The General Medical Council (GMC) conducts Tests of Competence (ToC) for doctors referred for Fitness to Practise (FtP) issues. GPs take a single best answer knowledge test, an Objective Structured Clinical Examination (OSCE), and a Simulated Surgery (SimSurg) assessment which is a simulated GP consultation. The aim of this study was to examine the similarities between OSCEs and SimSurg to determine whether each assessment contributed something unique to GP ToCs. A mixed methods approach was used. Data were collated on 153 GPs who were required to undertake a ToC as a part of being investigated for FtP issues between February 2010 and October 2016. Using correlation analysis, we examined to what degree performance on the knowledge test, OSCE, and SimSurg related to case examiner recommendations and FtP outcomes, including the unique predictive power of these three assessments. The outcome measures were case examiner recommendations (i) not fit to practise; ii) fit to practise on a limited basis; or iii) fit to practise) as well as FtP outcomes (i) erased/removed from the register; ii) having restrictions/conditions; or iii) be in good standing). For the qualitative component, 45 GP assessors were asked to rate whether they assess the same competencies and which assessment provides better feedback about candidates. There was significant overlap between OSCEs and SimSurg, p < 0.001. SimSurg had additional predictive power in the presence of OSCEs and the knowledge test (p = 0.030) in distinguishing doctors from different FtP categories, while OSCEs did not (p = 0.080). Both the OSCEs (p = 0.004) and SimSurg (p < 0.001) had significant negative correlations with case examiner recommendations when accounting for the effects of the other two assessments. Inductive thematic analysis of the responses to the questionnaire showed that assessors perceived OSCEs to be better suited to target specific knowledge and skills. SimSurg was thought to produce a

  16. Earthworm avoidance test for soil assessments. An alternative for acute and reproduction tests

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K.; Wiechering, H. [Fraunhofer-Inst. fuer Umweltchemie und Oekotoxikologie, Schmallenberg (Germany)

    2001-07-01

    For ecotoxicological assessments of contaminated or remediated soils pointing to the habitat function of soils for biocenoses, standardized tests with earthworms (acute test, reproduction test) are available among others. Tests used for routine applications should be sensitive and indicate impacts on test organisms after short test periods. The usually applied earthworm tests do not satisfactorily fulfil these criteria. Therefore, in the present work, a behavioural test with earthworms (test criterion: avoidance) was investigated in detail using uncontaminated, artificially contaminated and originally contaminated soils. It was demonstrated that the avoidance behaviour is primarily determined by pollutants, and not by chemical-physical soil properties. The sensitivity of the presented test reaches the sensitivity of established tests. For waste sites, a considerably higher sensitivity was determined. An avoidance behaviour of at least 80% of the worms leaving the soil to be assessed is proposed as a criterion for toxicity. (orig.)

  17. A method of accurate determination of voltage stability margin

    Energy Technology Data Exchange (ETDEWEB)

    Wiszniewski, A.; Rebizant, W. [Wroclaw Univ. of Technology, Wroclaw (Poland); Klimek, A. [AREVA Transmission and Distribution, Stafford (United Kingdom)

    2008-07-01

    In the process of developing power system disturbance, voltage instability at the receiving substations often contributes to deteriorating system stability, which eventually may lead to severe blackouts. The voltage stability margin at receiving substations may be used to determine measures to prevent voltage collapse, primarily by operating or blocking the transformer tap changing device, or by load shedding. The best measure of the stability margin is the actual load to source impedance ratio and its critical value, which is unity. This paper presented an accurate method of calculating the load to source impedance ratio, derived from the Thevenin's equivalent circuit of the system, which led to calculation of the stability margin. The paper described the calculation of the load to source impedance ratio including the supporting equations. The calculation was based on the very definition of voltage stability, which says that system stability is maintained as long as the change of power, which follows the increase of admittance is positive. The testing of the stability margin assessment method was performed in a simulative way for a number of power network structures and simulation scenarios. Results of the simulations revealed that this method is accurate and stable for all possible events occurring downstream of the device location. 3 refs., 8 figs.

  18. Investigation of the Validity and Reliability of Balance Evaluation Systems Test (BESTest in Assessment of Balance Disorders in People With Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Samira Kamalian Lari

    2018-01-01

    Conclusion  After changing and removing part of question 6 of the second domain, results demonstrated that the questionnaire BESTest is a valid and reliable test for assessing balance performance in multiple sclerosis patients. It can be used as an accurate tool, both in the areas of clinical (to evaluate the patients’ equilibrium status and purposeful therapy planning and to apply for scientific research in patients with multiple sclerosis.

  19. An Accurate Method for Inferring Relatedness in Large Datasets of Unphased Genotypes via an Embedded Likelihood-Ratio Test

    KAUST Repository

    Rodriguez, Jesse M.

    2013-01-01

    Studies that map disease genes rely on accurate annotations that indicate whether individuals in the studied cohorts are related to each other or not. For example, in genome-wide association studies, the cohort members are assumed to be unrelated to one another. Investigators can correct for individuals in a cohort with previously-unknown shared familial descent by detecting genomic segments that are shared between them, which are considered to be identical by descent (IBD). Alternatively, elevated frequencies of IBD segments near a particular locus among affected individuals can be indicative of a disease-associated gene. As genotyping studies grow to use increasingly large sample sizes and meta-analyses begin to include many data sets, accurate and efficient detection of hidden relatedness becomes a challenge. To enable disease-mapping studies of increasingly large cohorts, a fast and accurate method to detect IBD segments is required. We present PARENTE, a novel method for detecting related pairs of individuals and shared haplotypic segments within these pairs. PARENTE is a computationally-efficient method based on an embedded likelihood ratio test. As demonstrated by the results of our simulations, our method exhibits better accuracy than the current state of the art, and can be used for the analysis of large genotyped cohorts. PARENTE\\'s higher accuracy becomes even more significant in more challenging scenarios, such as detecting shorter IBD segments or when an extremely low false-positive rate is required. PARENTE is publicly and freely available at http://parente.stanford.edu/. © 2013 Springer-Verlag.

  20. A machine learned classifier that uses gene expression data to accurately predict estrogen receptor status.

    Directory of Open Access Journals (Sweden)

    Meysam Bastani

    Full Text Available BACKGROUND: Selecting the appropriate treatment for breast cancer requires accurately determining the estrogen receptor (ER status of the tumor. However, the standard for determining this status, immunohistochemical analysis of formalin-fixed paraffin embedded samples, suffers from numerous technical and reproducibility issues. Assessment of ER-status based on RNA expression can provide more objective, quantitative and reproducible test results. METHODS: To learn a parsimonious RNA-based classifier of hormone receptor status, we applied a machine learning tool to a training dataset of gene expression microarray data obtained from 176 frozen breast tumors, whose ER-status was determined by applying ASCO-CAP guidelines to standardized immunohistochemical testing of formalin fixed tumor. RESULTS: This produced a three-gene classifier that can predict the ER-status of a novel tumor, with a cross-validation accuracy of 93.17±2.44%. When applied to an independent validation set and to four other public databases, some on different platforms, this classifier obtained over 90% accuracy in each. In addition, we found that this prediction rule separated the patients' recurrence-free survival curves with a hazard ratio lower than the one based on the IHC analysis of ER-status. CONCLUSIONS: Our efficient and parsimonious classifier lends itself to high throughput, highly accurate and low-cost RNA-based assessments of ER-status, suitable for routine high-throughput clinical use. This analytic method provides a proof-of-principle that may be applicable to developing effective RNA-based tests for other biomarkers and conditions.

  1. A Case for Multidimensional Bilingual Assessment

    Science.gov (United States)

    Sanchez, Serafin V.; Rodriguez, Billie Jo; Soto-Huerta, Mary Esther; Villarreal, Felicia Castro; Guerra, Norma Susan; Flores, Belinda Bustos

    2013-01-01

    Current assessment practices in the United States are not able to accurately capture the total linguistic, cognitive, and achievement abilities of bilingual learners. There are psychometric complexities involved when assessing and interpreting test results of bilingual students, which impact the validity of this practice. Further, the compromise…

  2. Current status of accurate prognostic awareness in advanced/terminally ill cancer patients: Systematic review and meta-regression analysis.

    Science.gov (United States)

    Chen, Chen Hsiu; Kuo, Su Ching; Tang, Siew Tzuh

    2017-05-01

    No systematic meta-analysis is available on the prevalence of cancer patients' accurate prognostic awareness and differences in accurate prognostic awareness by publication year, region, assessment method, and service received. To examine the prevalence of advanced/terminal cancer patients' accurate prognostic awareness and differences in accurate prognostic awareness by publication year, region, assessment method, and service received. Systematic review and meta-analysis. MEDLINE, Embase, The Cochrane Library, CINAHL, and PsycINFO were systematically searched on accurate prognostic awareness in adult patients with advanced/terminal cancer (1990-2014). Pooled prevalences were calculated for accurate prognostic awareness by a random-effects model. Differences in weighted estimates of accurate prognostic awareness were compared by meta-regression. In total, 34 articles were retrieved for systematic review and meta-analysis. At best, only about half of advanced/terminal cancer patients accurately understood their prognosis (49.1%; 95% confidence interval: 42.7%-55.5%; range: 5.4%-85.7%). Accurate prognostic awareness was independent of service received and publication year, but highest in Australia, followed by East Asia, North America, and southern Europe and the United Kingdom (67.7%, 60.7%, 52.8%, and 36.0%, respectively; p = 0.019). Accurate prognostic awareness was higher by clinician assessment than by patient report (63.2% vs 44.5%, p cancer patients accurately understood their prognosis, with significant variations by region and assessment method. Healthcare professionals should thoroughly assess advanced/terminal cancer patients' preferences for prognostic information and engage them in prognostic discussion early in the cancer trajectory, thus facilitating their accurate prognostic awareness and the quality of end-of-life care decision-making.

  3. [The methodological assessment and qualitative evaluation of psychometric performance tests based on the example of modern tests that assess reading and spelling skills].

    Science.gov (United States)

    Galuschka, Katharina; Rothe, Josefine; Schulte-Körne, Gerd

    2015-09-01

    This article looks at a means of objectively evaluating the quality of psychometric tests. This approach enables users to evaluate psychometric tests based on their methodological characteristics, in order to decide which instrument should be used. Reading and spelling assessment tools serve as examples. The paper also provides a review of German psychometric tests for the assessment of reading and spelling skills. This method facilitates the identification of psychometric tests.of high methodological quality which can be used for the assessment of reading and spelling skills. Reading performance should ideally be assessed with the following instruments: ELFE 1-6, LGVT 6-12, LESEN 6-7, LESEN 8-9, or WLLP-R. The tests to be used for the evaluation of spelling skills are DERET 1-2+, DERET 3-4+, WRT 1+, WRT 2+, WRT 3+, WRT 4+ or HSP 1-10.

  4. Assessing Mediational Models: Testing and Interval Estimation for Indirect Effects.

    Science.gov (United States)

    Biesanz, Jeremy C; Falk, Carl F; Savalei, Victoria

    2010-08-06

    Theoretical models specifying indirect or mediated effects are common in the social sciences. An indirect effect exists when an independent variable's influence on the dependent variable is mediated through an intervening variable. Classic approaches to assessing such mediational hypotheses ( Baron & Kenny, 1986 ; Sobel, 1982 ) have in recent years been supplemented by computationally intensive methods such as bootstrapping, the distribution of the product methods, and hierarchical Bayesian Markov chain Monte Carlo (MCMC) methods. These different approaches for assessing mediation are illustrated using data from Dunn, Biesanz, Human, and Finn (2007). However, little is known about how these methods perform relative to each other, particularly in more challenging situations, such as with data that are incomplete and/or nonnormal. This article presents an extensive Monte Carlo simulation evaluating a host of approaches for assessing mediation. We examine Type I error rates, power, and coverage. We study normal and nonnormal data as well as complete and incomplete data. In addition, we adapt a method, recently proposed in statistical literature, that does not rely on confidence intervals (CIs) to test the null hypothesis of no indirect effect. The results suggest that the new inferential method-the partial posterior p value-slightly outperforms existing ones in terms of maintaining Type I error rates while maximizing power, especially with incomplete data. Among confidence interval approaches, the bias-corrected accelerated (BC a ) bootstrapping approach often has inflated Type I error rates and inconsistent coverage and is not recommended; In contrast, the bootstrapped percentile confidence interval and the hierarchical Bayesian MCMC method perform best overall, maintaining Type I error rates, exhibiting reasonable power, and producing stable and accurate coverage rates.

  5. Assessing reference genes for accurate transcript normalization using quantitative real-time PCR in pearl millet [Pennisetum glaucum (L. R. Br].

    Directory of Open Access Journals (Sweden)

    Prasenjit Saha

    Full Text Available Pearl millet [Pennisetum glaucum (L. R.Br.], a close relative of Panicoideae food crops and bioenergy grasses, offers an ideal system to perform functional genomics studies related to C4 photosynthesis and abiotic stress tolerance. Quantitative real-time reverse transcription polymerase chain reaction (qRT-PCR provides a sensitive platform to conduct such gene expression analyses. However, the lack of suitable internal control reference genes for accurate transcript normalization during qRT-PCR analysis in pearl millet is the major limitation. Here, we conducted a comprehensive assessment of 18 reference genes on 234 samples which included an array of different developmental tissues, hormone treatments and abiotic stress conditions from three genotypes to determine appropriate reference genes for accurate normalization of qRT-PCR data. Analyses of Ct values using Stability Index, BestKeeper, ΔCt, Normfinder, geNorm and RefFinder programs ranked PP2A, TIP41, UBC2, UBQ5 and ACT as the most reliable reference genes for accurate transcript normalization under different experimental conditions. Furthermore, we validated the specificity of these genes for precise quantification of relative gene expression and provided evidence that a combination of the best reference genes are required to obtain optimal expression patterns for both endogeneous genes as well as transgenes in pearl millet.

  6. Prevalence of accurate nursing documentation in patient records

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    AIM: This paper is a report of a study conducted to describe the accuracy of nursing documentation in patient records in hospitals. Background.  Accurate nursing documentation enables nurses to systematically review the nursing process and to evaluate the quality of care. Assessing nurses' reports

  7. Adapting the Critical Thinking Assessment Test for Palestinian Universities

    Science.gov (United States)

    Basha, Sami; Drane, Denise; Light, Gregory

    2016-01-01

    Critical thinking is a key learning outcome for Palestinian students. However, there are no validated critical thinking tests in Arabic. Suitability of the US developed Critical Thinking Assessment Test (CAT) for use in Palestine was assessed. The test was piloted with university students in English (n = 30) and 4 questions were piloted in Arabic…

  8. Behavioral and fMRI evidence of the differing cognitive load of domain-specific assessments.

    Science.gov (United States)

    Howard, S J; Burianová, H; Ehrich, J; Kervin, L; Calleia, A; Barkus, E; Carmody, J; Humphry, S

    2015-06-25

    Standards-referenced educational reform has increased the prevalence of standardized testing; however, whether these tests accurately measure students' competencies has been questioned. This may be due to domain-specific assessments placing a differing domain-general cognitive load on test-takers. To investigate this possibility, functional magnetic resonance imaging (fMRI) was used to identify and quantify the neural correlates of performance on current, international standardized methods of spelling assessment. Out-of-scanner testing was used to further examine differences in assessment results. Results provide converging evidence that: (a) the spelling assessments differed in the cognitive load placed on test-takers; (b) performance decreased with increasing cognitive load of the assessment; and (c) brain regions associated with working memory were more highly activated during performance of assessments that were higher in cognitive load. These findings suggest that assessment design should optimize the cognitive load placed on test-takers, to ensure students' results are an accurate reflection of their true levels of competency. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. SpineAnalyzer™ is an accurate and precise method of vertebral fracture detection and classification on dual-energy lateral vertebral assessment scans

    International Nuclear Information System (INIS)

    Birch, C.; Knapp, K.; Hopkins, S.; Gallimore, S.; Rock, B.

    2015-01-01

    Osteoporotic fractures of the spine are associated with significant morbidity, are highly predictive of hip fractures, but frequently do not present clinically. When there is a low to moderate clinical suspicion of vertebral fracture, which would not justify acquisition of a radiograph, vertebral fracture assessment (VFA) using Dual-energy X-ray Absorptiometry (DXA) offers a low-dose opportunity for diagnosis. Different approaches to the classification of vertebral fractures have been documented. The aim of this study was to measure the precision and accuracy of SpineAnalyzer™, a quantitative morphometry software program. Lateral vertebral assessment images of 64 men were analysed using SpineAnalyzer™ and standard GE Lunar software. The images were also analysed by two expert readers using a semi-quantitative approach. Agreement between groups ranged from 95.99% to 98.60%. The intra-rater precision for the application of SpineAnalyzer™ to vertebrae was poor in the upper thoracic regions, but good elsewhere. SpineAnalyzer™ is a reproducible and accurate method for measuring vertebral height and quantifying vertebral fractures from VFA scans. - Highlights: • Vertebral fracture assessment (VFA) using Dual-energy X-ray Absorptiometry (DXA) offers a low-dose opportunity for diagnosis. • Agreement between VFA software (SpineAnalyzer™) and expert readers is high. • Intra-rater precision of SpineAnalyzer™ applied to upper thoracic vertebrae is poor, but good elsewhere. • SpineAnalyzer™ is reproducible and accurate for vertebral height measurement and fracture quantification from VFA scans

  10. Biomimetic Approach for Accurate, Real-Time Aerodynamic Coefficients, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Aerodynamic and structural reliability and efficiency depends critically on the ability to accurately assess the aerodynamic loads and moments for each lifting...

  11. IMAGE CAPTURE WITH SYNCHRONIZED MULTIPLE-CAMERAS FOR EXTRACTION OF ACCURATE GEOMETRIES

    Directory of Open Access Journals (Sweden)

    M. Koehl

    2016-06-01

    Full Text Available This paper presents a project of recording and modelling tunnels, traffic circles and roads from multiple sensors. The aim is the representation and the accurate 3D modelling of a selection of road infrastructures as dense point clouds in order to extract profiles and metrics from it. Indeed, these models will be used for the sizing of infrastructures in order to simulate exceptional convoy truck routes. The objective is to extract directly from the point clouds the heights, widths and lengths of bridges and tunnels, the diameter of gyrating and to highlight potential obstacles for a convoy. Light, mobile and fast acquisition approaches based on images and videos from a set of synchronized sensors have been tested in order to obtain useable point clouds. The presented solution is based on a combination of multiple low-cost cameras designed on an on-boarded device allowing dynamic captures. The experimental device containing GoPro Hero4 cameras has been set up and used for tests in static or mobile acquisitions. That way, various configurations have been tested by using multiple synchronized cameras. These configurations are discussed in order to highlight the best operational configuration according to the shape of the acquired objects. As the precise calibration of each sensor and its optics are major factors in the process of creation of accurate dense point clouds, and in order to reach the best quality available from such cameras, the estimation of the internal parameters of fisheye lenses of the cameras has been processed. Reference measures were also realized by using a 3D TLS (Faro Focus 3D to allow the accuracy assessment.

  12. Image Capture with Synchronized Multiple-Cameras for Extraction of Accurate Geometries

    Science.gov (United States)

    Koehl, M.; Delacourt, T.; Boutry, C.

    2016-06-01

    This paper presents a project of recording and modelling tunnels, traffic circles and roads from multiple sensors. The aim is the representation and the accurate 3D modelling of a selection of road infrastructures as dense point clouds in order to extract profiles and metrics from it. Indeed, these models will be used for the sizing of infrastructures in order to simulate exceptional convoy truck routes. The objective is to extract directly from the point clouds the heights, widths and lengths of bridges and tunnels, the diameter of gyrating and to highlight potential obstacles for a convoy. Light, mobile and fast acquisition approaches based on images and videos from a set of synchronized sensors have been tested in order to obtain useable point clouds. The presented solution is based on a combination of multiple low-cost cameras designed on an on-boarded device allowing dynamic captures. The experimental device containing GoPro Hero4 cameras has been set up and used for tests in static or mobile acquisitions. That way, various configurations have been tested by using multiple synchronized cameras. These configurations are discussed in order to highlight the best operational configuration according to the shape of the acquired objects. As the precise calibration of each sensor and its optics are major factors in the process of creation of accurate dense point clouds, and in order to reach the best quality available from such cameras, the estimation of the internal parameters of fisheye lenses of the cameras has been processed. Reference measures were also realized by using a 3D TLS (Faro Focus 3D) to allow the accuracy assessment.

  13. Potential Errors and Test Assessment in Software Product Line Engineering

    Directory of Open Access Journals (Sweden)

    Hartmut Lackner

    2015-04-01

    Full Text Available Software product lines (SPL are a method for the development of variant-rich software systems. Compared to non-variable systems, testing SPLs is extensive due to an increasingly amount of possible products. Different approaches exist for testing SPLs, but there is less research for assessing the quality of these tests by means of error detection capability. Such test assessment is based on error injection into correct version of the system under test. However to our knowledge, potential errors in SPL engineering have never been systematically identified before. This article presents an overview over existing paradigms for specifying software product lines and the errors that can occur during the respective specification processes. For assessment of test quality, we leverage mutation testing techniques to SPL engineering and implement the identified errors as mutation operators. This allows us to run existing tests against defective products for the purpose of test assessment. From the results, we draw conclusions about the error-proneness of the surveyed SPL design paradigms and how quality of SPL tests can be improved.

  14. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  15. Can cancer researchers accurately judge whether preclinical reports will reproduce?

    Directory of Open Access Journals (Sweden)

    Daniel Benjamin

    2017-06-01

    Full Text Available There is vigorous debate about the reproducibility of research findings in cancer biology. Whether scientists can accurately assess which experiments will reproduce original findings is important to determining the pace at which science self-corrects. We collected forecasts from basic and preclinical cancer researchers on the first 6 replication studies conducted by the Reproducibility Project: Cancer Biology (RP:CB to assess the accuracy of expert judgments on specific replication outcomes. On average, researchers forecasted a 75% probability of replicating the statistical significance and a 50% probability of replicating the effect size, yet none of these studies successfully replicated on either criterion (for the 5 studies with results reported. Accuracy was related to expertise: experts with higher h-indices were more accurate, whereas experts with more topic-specific expertise were less accurate. Our findings suggest that experts, especially those with specialized knowledge, were overconfident about the RP:CB replicating individual experiments within published reports; researcher optimism likely reflects a combination of overestimating the validity of original studies and underestimating the difficulties of repeating their methodologies.

  16. Puzzle test: A tool for non-analytical clinical reasoning assessment.

    Science.gov (United States)

    Monajemi, Alireza; Yaghmaei, Minoo

    2016-01-01

    Most contemporary clinical reasoning tests typically assess non-automatic thinking. Therefore, a test is needed to measure automatic reasoning or pattern recognition, which has been largely neglected in clinical reasoning tests. The Puzzle Test (PT) is dedicated to assess automatic clinical reasoning in routine situations. This test has been introduced first in 2009 by Monajemi et al in the Olympiad for Medical Sciences Students.PT is an item format that has gained acceptance in medical education, but no detailed guidelines exist for this test's format, construction and scoring. In this article, a format is described and the steps to prepare and administer valid and reliable PTs are presented. PT examines a specific clinical reasoning task: Pattern recognition. PT does not replace other clinical reasoning assessment tools. However, it complements them in strategies for assessing comprehensive clinical reasoning.

  17. Early Phonological Development: Creating an Assessment Test

    Science.gov (United States)

    Stoel-Gammon, Carol; Williams, A. Lynn

    2013-01-01

    This paper describes a new protocol for assessing the phonological systems of two-year-olds with typical development and older children with delays in vocabulary acquisition. The test (Profiles of Early Expressive Phonological Skills ("PEEPS"), Williams & Stoel-Gammon, in preparation) differs from currently available assessments in…

  18. Hydrogen sulfide detection based on reflection: from a poison test approach of ancient China to single-cell accurate localization.

    Science.gov (United States)

    Kong, Hao; Ma, Zhuoran; Wang, Song; Gong, Xiaoyun; Zhang, Sichun; Zhang, Xinrong

    2014-08-05

    With the inspiration of an ancient Chinese poison test approach, we report a rapid hydrogen sulfide detection strategy in specific areas of live cells using silver needles with good spatial resolution of 2 × 2 μm(2). Besides the accurate-localization ability, this reflection-based strategy also has attractive merits of convenience and robust response when free pretreatment and short detection time are concerned. The success of endogenous H2S level evaluation in cellular cytoplasm and nuclear of human A549 cells promises the application potential of our strategy in scientific research and medical diagnosis.

  19. Advanced Test Reactor probabilistic risk assessment

    International Nuclear Information System (INIS)

    Atkinson, S.A.; Eide, S.A.; Khericha, S.T.; Thatcher, T.A.

    1993-01-01

    This report discusses Level 1 probabilistic risk assessment (PRA) incorporating a full-scope external events analysis which has been completed for the Advanced Test Reactor (ATR) located at the Idaho National Engineering Laboratory

  20. The tap test- an accurate First-line test for fetal lung maturity testing ...

    African Journals Online (AJOL)

    Objective. To determine the accuracy of near-patient and laboratory- based fetal lung maturity tests in predicting the need for neonatal ventilation. Design. A prospective descriptive study. Subjects. One hundred high-risk obstetric patients where confirmation of fetal lung maturity would initiate delivery. Methods. Fetal weight ...

  1. On accurate determination of contact angle

    Science.gov (United States)

    Concus, P.; Finn, R.

    1992-01-01

    Methods are proposed that exploit a microgravity environment to obtain highly accurate measurement of contact angle. These methods, which are based on our earlier mathematical results, do not require detailed measurement of a liquid free-surface, as they incorporate discontinuous or nearly-discontinuous behavior of the liquid bulk in certain container geometries. Physical testing is planned in the forthcoming IML-2 space flight and in related preparatory ground-based experiments.

  2. Combination of blood tests for significant fibrosis and cirrhosis improves the assessment of liver-prognosis in chronic hepatitis C.

    Science.gov (United States)

    Boursier, J; Brochard, C; Bertrais, S; Michalak, S; Gallois, Y; Fouchard-Hubert, I; Oberti, F; Rousselet, M-C; Calès, P

    2014-07-01

    Recent longitudinal studies have emphasised the prognostic value of noninvasive tests of liver fibrosis and cross-sectional studies have shown their combination significantly improves diagnostic accuracy. To compare the prognostic accuracy of six blood fibrosis tests and liver biopsy, and evaluate if test combination improves the liver-prognosis assessment in chronic hepatitis C (CHC). A total of 373 patients with compensated CHC, liver biopsy (Metavir F) and blood tests targeting fibrosis (APRI, FIB4, Fibrotest, Hepascore, FibroMeter) or cirrhosis (CirrhoMeter) were included. Significant liver-related events (SLRE) and liver-related deaths were recorded during follow-up (started the day of biopsy). During the median follow-up of 9.5 years (3508 person-years), 47 patients had a SLRE and 23 patients died from liver-related causes. For the prediction of first SLRE, most blood tests allowed higher prognostication than Metavir F [Harrell C-index: 0.811 (95% CI: 0.751-0.868)] with a significant increase for FIB4: 0.879 [0.832-0.919] (P = 0.002), FibroMeter: 0.870 [0.812-0.922] (P = 0.005) and APRI: 0.861 [0.813-0.902] (P = 0.039). Multivariate analysis identified FibroMeter, CirrhoMeter and sustained viral response as independent predictors of first SLRE. CirrhoMeter was the only independent predictor of liver-related death. The combination of FibroMeter and CirrhoMeter classifications into a new FM/CM classification improved the liver-prognosis assessment compared to Metavir F staging or single tests by identifying five subgroups of patients with significantly different prognoses. Some blood fibrosis tests are more accurate than liver biopsy for determining liver prognosis in CHC. A new combination of two complementary blood tests, one targeted for fibrosis and the other for cirrhosis, optimises assessment of liver-prognosis. © 2014 John Wiley & Sons Ltd.

  3. Preliminary Options Assessment of Versatile Irradiation Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Ramazan Sonat [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    The objective of this report is to summarize the work undertaken at INL from April 2016 to January 2017 and aimed at analyzing some options for designing and building a versatile test reactor; the scope of work was agreed upon with DOE-NE. Section 2 presents some results related to KNK II and PRISM Mod A. Section 3 presents some alternatives to the VCTR presented in [ ] as well as a neutronic parametric study to assess the minimum power requirement needed for a 235U metal fueled fast test reactor capable to generate a fast (>100 keV) flux of 4.0 x 1015 n /cm2-s at the test location. Section 4 presents some results regarding a fundamental characteristic of test reactors, namely displacement per atom (dpa) in test samples. Section 5 presents the INL assessment of the ANL fast test reactor design FASTER. Section 6 presents a summary.

  4. Psychological testing and psychological assessment. A review of evidence and issues.

    Science.gov (United States)

    Meyer, G J; Finn, S E; Eyde, L D; Kay, G G; Moreland, K L; Dies, R R; Eisman, E J; Kubiszyn, T W; Reed, G M

    2001-02-01

    This article summarizes evidence and issues associated with psychological assessment. Data from more than 125 meta-analyses on test validity and 800 samples examining multimethod assessment suggest 4 general conclusions: (a) Psychological test validity is strong and compelling, (b) psychological test validity is comparable to medical test validity, (c) distinct assessment methods provide unique sources of information, and (d) clinicians who rely exclusively on interviews are prone to incomplete understandings. Following principles for optimal nomothetic research, the authors suggest that a multimethod assessment battery provides a structured means for skilled clinicians to maximize the validity of individualized assessments. Future investigations should move beyond an examination of test scales to focus more on the role of psychologists who use tests as helpful tools to furnish patients and referral sources with professional consultation.

  5. Assessing the performance of commercial Agisoft PhotoScan software to deliver reliable data for accurate3D modelling

    Directory of Open Access Journals (Sweden)

    Jebur Ahmed

    2018-01-01

    Full Text Available 3D models delivered from digital photogrammetric techniques have massively increased and developed to meet the requirements of many applications. The reliability of these models is basically dependent on the data processing cycle and the adopted tool solution in addition to data quality. Agisoft PhotoScan is a professional image-based 3D modelling software, which seeks to create orderly, precise n 3D content from fixed images. It works with arbitrary images those qualified in both controlled and uncontrolled conditions. Following the recommendations of many users all around the globe, Agisoft PhotoScan, has become an important source to generate precise 3D data for different applications. How reliable is this data for accurate 3D modelling applications is the current question that needs an answer. Therefore; in this paper, the performance of the Agisoft PhotoScan software was assessed and analyzed to show the potential of the software for accurate 3D modelling applications. To investigate this, a study was carried out in the University of Baghdad / Al-Jaderia campus using data collected from airborne metric camera with 457m flying height. The Agisoft results show potential according to the research objective and the dataset quality following statistical and validation shape analysis.

  6. Can emergency physicians accurately and reliably assess acute vertigo in the emergency department?

    Science.gov (United States)

    Vanni, Simone; Nazerian, Peiman; Casati, Carlotta; Moroni, Federico; Risso, Michele; Ottaviani, Maddalena; Pecci, Rudi; Pepe, Giuseppe; Vannucchi, Paolo; Grifoni, Stefano

    2015-04-01

    To validate a clinical diagnostic tool, used by emergency physicians (EPs), to diagnose the central cause of patients presenting with vertigo, and to determine interrater reliability of this tool. A convenience sample of adult patients presenting to a single academic ED with isolated vertigo (i.e. vertigo without other neurological deficits) was prospectively evaluated with STANDING (SponTAneousNystagmus, Direction, head Impulse test, standiNG) by five trained EPs. The first step focused on the presence of spontaneous nystagmus, the second on the direction of nystagmus, the third on head impulse test and the fourth on gait. The local standard practice, senior audiologist evaluation corroborated by neuroimaging when deemed appropriate, was considered the reference standard. Sensitivity and specificity of STANDING were calculated. On the first 30 patients, inter-observer agreement among EPs was also assessed. Five EPs with limited experience in nystagmus assessment volunteered to participate in the present study enrolling 98 patients. Their average evaluation time was 9.9 ± 2.8 min (range 6-17). Central acute vertigo was suspected in 16 (16.3%) patients. There were 13 true positives, three false positives, 81 true negatives and one false negative, with a high sensitivity (92.9%, 95% CI 70-100%) and specificity (96.4%, 95% CI 93-38%) for central acute vertigo according to senior audiologist evaluation. The Cohen's kappas of the first, second, third and fourth steps of the STANDING were 0.86, 0.93, 0.73 and 0.78, respectively. The whole test showed a good inter-observer agreement (k = 0.76, 95% CI 0.45-1). In the hands of EPs, STANDING showed a good inter-observer agreement and accuracy validated against the local standard of care. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  7. Wald Sequential Probability Ratio Test for Space Object Conjunction Assessment

    Science.gov (United States)

    Carpenter, James R.; Markley, F Landis

    2014-01-01

    This paper shows how satellite owner/operators may use sequential estimates of collision probability, along with a prior assessment of the base risk of collision, in a compound hypothesis ratio test to inform decisions concerning collision risk mitigation maneuvers. The compound hypothesis test reduces to a simple probability ratio test, which appears to be a novel result. The test satisfies tolerances related to targeted false alarm and missed detection rates. This result is independent of the method one uses to compute the probability density that one integrates to compute collision probability. A well-established test case from the literature shows that this test yields acceptable results within the constraints of a typical operational conjunction assessment decision timeline. Another example illustrates the use of the test in a practical conjunction assessment scenario based on operations of the International Space Station.

  8. Operational Based Vision Assessment Automated Vision Test Collection User Guide

    Science.gov (United States)

    2017-05-15

    AFRL-SA-WP-SR-2017-0012 Operational Based Vision Assessment Automated Vision Test Collection User Guide Elizabeth Shoda, Alex...June 2015 – May 2017 4. TITLE AND SUBTITLE Operational Based Vision Assessment Automated Vision Test Collection User Guide 5a. CONTRACT NUMBER... automated vision tests , or AVT. Development of the AVT was required to support threshold-level vision testing capability needed to investigate the

  9. Using a Bedside Video-assisted Test Tube Test to Assess Stoma Viability: A Report of 4 Cases.

    Science.gov (United States)

    Ahmad, Sarwat; Turner, Keli; Shah, Paulesh; Diaz, Jose

    2016-07-01

    Mucosal discoloration of an intestinal stoma may indicate self-limited venous congestion or necrosis necessitating operative revision. A common bedside technique to assess stoma viability is the "test tube test". A clear tube is inserted into the stoma and a hand-held light is used to assess the color of the stoma. A technique (video-assisted test tube test [VATTT]) developed by the authors utilizes a standard video bronchoscope inserted into a clear plastic blood collection tube to visually inspect and assess the mucosa. This technique was evaluated in 4 patients (age range 49-72 years, all critically ill) with a discolored stoma after emergency surgery. In each case, physical exam revealed ischemic mucosa at the surface either immediately after surgery or after worsening hypotension weeks later. Serial test tube test assessments were ambiguous when trying to assess deeper mucosa. The VATTT assessment showed viable pink mucosa beneath the surface and until the fascia was revealed in 3 patients. One (1) patient had mucosal ischemia down to the fascia, which prompted operative revision of the stoma. The new stoma was assessed with a VATTT and was viable for the entire length of the stoma. VATTT provided an enhanced, magnified, and clearer way to visually assess stoma viability in the postoperative period that can be performed at the bedside with no adverse events. It may prevent unnecessary relaparotomy or enable earlier diagnosis of deep ostomy necrosis. Validity and reliability studies are warranted.

  10. Caveats for using statistical significance tests in research assessments

    DEFF Research Database (Denmark)

    Schneider, Jesper Wiborg

    2013-01-01

    controversial and numerous criticisms have been leveled against their use. Based on examples from articles by proponents of the use statistical significance tests in research assessments, we address some of the numerous problems with such tests. The issues specifically discussed are the ritual practice......This article raises concerns about the advantages of using statistical significance tests in research assessments as has recently been suggested in the debate about proper normalization procedures for citation indicators by Opthof and Leydesdorff (2010). Statistical significance tests are highly...... argue that applying statistical significance tests and mechanically adhering to their results are highly problematic and detrimental to critical thinking. We claim that the use of such tests do not provide any advantages in relation to deciding whether differences between citation indicators...

  11. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.; Rohatgi, U.S.

    1995-01-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations al these conditions were compared with the GIRAFFE data. The effects of PCCS cell nodings on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to ±5% of the data with a three-node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer in the presence of noncondensable gases with only a coarse mesh. The cell length term in the condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes

  12. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    International Nuclear Information System (INIS)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C.

    1995-01-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba's Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to ±5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes

  13. An assessment of RELAP5 MOD3.1.1 condensation heat transfer modeling with GIRAFFE heat transfer tests

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, B.D.; Parlatan, Y.; Slovik, G.C. [and others

    1995-09-01

    RELAP5 MOD3.1.1 is being used to simulate Loss of Coolant Accidents (LOCA) for the Simplified Boiling Water Reactor (SBWR) being proposed by General Electric (GE). One of the major components associated with the SBWR is the Passive Containment Cooling System (PCCS) which provides the long-term heat sink to reject decay heat. The RELAP5 MOD3.1.1 code is being assessed for its ability to represent accurately the PCCS. Data from the Phase 1, Step 1 Heat Transfer Tests performed at Toshiba`s Gravity-Driven Integral Full-Height Test for Passive Heat Removal (GIRAFFE) facility will be used for assessing the ability of RELAP5 to model condensation in the presence of noncondensables. The RELAP5 MOD3.1.1 condensation model uses the University of California at Berkeley (UCB) correlation developed by Vierow and Schrock. The RELAP5 code uses this heat transfer coefficient with the gas velocity effect multiplier being limited to 2. This heat transfer option was used to analyze the condensation heat transfer in the GIRAFFE PCCS heat exchanger tubes in the Phase 1, Step 1 Heat Transfer Tests which were at a pressure of 3 bar and had a range of nitrogen partial pressure fractions from 0.0 to 0.10. The results of a set of RELAP5 calculations at these conditions were compared with the GIRAFFE data. The effects of PCCS cell noding on the heat transfer process were also studied. The UCB correlation, as implemented in RELAP5, predicted the heat transfer to {plus_minus}5% of the data with a three--node model. The three-node model has a large cell in the entrance region which smeared out the entrance effects on the heat transfer, which tend to overpredict the condensation. Hence, the UCB correlation predicts condensation heat transfer correlation implemented in the code must be removed to allow for accurate calculations with smaller cell sizes.

  14. Microsoft Kinect-based Continuous Performance Test: An Objective Attention Deficit Hyperactivity Disorder Assessment.

    Science.gov (United States)

    Delgado-Gomez, David; Peñuelas-Calvo, Inmaculada; Masó-Besga, Antonio Eduardo; Vallejo-Oñate, Silvia; Baltasar Tello, Itziar; Arrua Duarte, Elsa; Vera Varela, María Constanza; Carballo, Juan; Baca-García, Enrique

    2017-03-20

    One of the major challenges in mental medical care is finding out new instruments for an accurate and objective evaluation of the attention deficit hyperactivity disorder (ADHD). Early ADHD identification, severity assessment, and prompt treatment are essential to avoid the negative effects associated with this mental condition. The aim of our study was to develop a novel ADHD assessment instrument based on Microsoft Kinect, which identifies ADHD cardinal symptoms in order to provide a more accurate evaluation. A group of 30 children, aged 8-12 years (10.3 [SD 1.4]; male 70% [21/30]), who were referred to the Child and Adolescent Psychiatry Unit of the Department of Psychiatry at Fundación Jiménez Díaz Hospital (Madrid, Spain), were included in this study. Children were required to meet the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) criteria of ADHD diagnosis. One of the parents or guardians of the children filled the Spanish version of the Strengths and Weaknesses of ADHD Symptoms and Normal Behavior (SWAN) rating scale used in clinical practice. Each child conducted a Kinect-based continuous performance test (CPT) in which the reaction time (RT), the commission errors, and the time required to complete the reaction (CT) were calculated. The correlations of the 3 predictors, obtained using Kinect methodology, with respect to the scores of the SWAN scale were calculated. The RT achieved a correlation of -.11, -.29, and -.37 with respect to the inattention, hyperactivity, and impulsivity factors of the SWAN scale. The correlations of the commission error with respect to these 3 factors were -.03, .01, and .24, respectively. Our findings show a relation between the Microsoft Kinect-based version of the CPT and ADHD symptomatology assessed through parental report. Results point out the importance of future research on the development of objective measures for the diagnosis of ADHD among children and adolescents. ©David Delgado-Gomez, Inmaculada

  15. Practice effects and test-re-test reliability of the Five Digit Test in patients with stroke over four serial assessments.

    Science.gov (United States)

    Chiu, En-Chi; Koh, Chia-Lin; Tsai, Chia-Yin; Lu, Wen-Shian; Sheu, Ching-Fan; Hsueh, I-Ping; Hsieh, Ching-Lin

    2014-01-01

    To investigate practice effect and test-re-test reliability of the Five Digit Test (FDT) over four serial assessments in patients with stroke. Single-group repeated measures design. Twenty-five patients with stroke were administered the FDT in four consecutive assessments every 2 weeks. The FDT contains four parts with five indices: 'basic measures of attention and processing speed', 'selective attention', 'alternating attention', 'ability of inhibition' and 'ability of switching'. The five indices of the FDT showed trivial-to-small practice effects (Cohen's d = 0.03-0.47) and moderate-to-excellent test-re-test reliability (intra-class correlation coefficient = 0.59-0.97). Practice effects of the five indices all appeared cumulative, but one index, 'basic measures of attention and processing speed', reached a plateau after the second assessment. The minimum and maximum values of the 90% confidence interval (CI) of reliable change index modified for practice (RCIp) for this index were [-17.6, 11.2]. One of five indices of the FDT reached a plateau, whose minimum and maximum values of the 90% CI RCIp are useful to determine whether the change in an individual's score is real. However, clinicians and researchers should be cautious when interpreting the test results of these four indices over repeated assessments.

  16. Is functional MR imaging assessment of hemispheric language dominance as good as the Wada test?: a meta-analysis.

    Science.gov (United States)

    Dym, R Joshua; Burns, Judah; Freeman, Katherine; Lipton, Michael L

    2011-11-01

    To perform a systematic review and meta-analysis to quantitatively assess functional magnetic resonance (MR) imaging lateralization of language function in comparison with the Wada test. This study was determined to be exempt from review by the institutional review board. A systematic review and meta-analysis were performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A structured Medline search was conducted to identify all studies that compared functional MR imaging with the Wada test for determining hemispheric language dominance prior to brain surgery. Studies meeting predetermined inclusion criteria were selected independently by two radiologists who also assessed their quality using the Quality Assessment of Diagnostic Accuracy Studies tool. Language dominance was classified as typical (left hemispheric language dominance) or atypical (right hemispheric language dominance or bilateral language representation) for each patient. A meta-analysis was then performed by using a bivariate random-effects model to derive estimates of sensitivity and specificity, with Wada as the standard of reference. Subgroup analyses were also performed to compare the different functional MR imaging techniques utilized by the studies. Twenty-three studies, comprising 442 patients, met inclusion criteria. The sensitivity and specificity of functional MR imaging for atypical language dominance (compared with the Wada test) were 83.5% (95% confidence interval: 80.2%, 86.7%) and 88.1% (95% confidence interval: 87.0%, 89.2%), respectively. Functional MR imaging provides an excellent, noninvasive alternative for language lateralization and should be considered for the initial preoperative assessment of hemispheric language dominance. Further research may help determine which functional MR methods are most accurate for specific patient populations. RSNA, 2011

  17. FY11 Facility Assessment Study for Aeronautics Test Program

    Science.gov (United States)

    Loboda, John A.; Sydnor, George H.

    2013-01-01

    This paper presents the approach and results for the Aeronautics Test Program (ATP) FY11 Facility Assessment Project. ATP commissioned assessments in FY07 and FY11 to aid in the understanding of the current condition and reliability of its facilities and their ability to meet current and future (five year horizon) test requirements. The principle output of the assessment was a database of facility unique, prioritized investments projects with budgetary cost estimates. This database was also used to identify trends for the condition of facility systems.

  18. Accurate Modeling of Advanced Reflectarrays

    DEFF Research Database (Denmark)

    Zhou, Min

    to the conventional phase-only optimization technique (POT), the geometrical parameters of the array elements are directly optimized to fulfill the far-field requirements, thus maintaining a direct relation between optimization goals and optimization variables. As a result, better designs can be obtained compared...... of the incident field, the choice of basis functions, and the technique to calculate the far-field. Based on accurate reference measurements of two offset reflectarrays carried out at the DTU-ESA Spherical NearField Antenna Test Facility, it was concluded that the three latter factors are particularly important...... using the GDOT to demonstrate its capabilities. To verify the accuracy of the GDOT, two offset contoured beam reflectarrays that radiate a high-gain beam on a European coverage have been designed and manufactured, and subsequently measured at the DTU-ESA Spherical Near-Field Antenna Test Facility...

  19. Blood: Tests Used to Assess the Physiological and Immunological Properties of Blood

    Science.gov (United States)

    Quinn, J. G.; Tansey, E. A.; Johnson, C. D.; Roe, S. M.; Montgomery, L. E. A.

    2016-01-01

    The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin…

  20. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  1. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  2. Test method to assess interface adhesion in composite bonding

    NARCIS (Netherlands)

    Teixeira de Freitas, S.; Sinke, J.

    2015-01-01

    This paper introduces a new type of peel tests dedicated to composite bonding: Composite Peel Tests. This test is inspired on the standard floating roller peel test widely used for metal bonding. The aim of this study is to investigate the potential of the Composite Peel Test to assess interface

  3. THEORY AND PRACTICE OF DESIGNING COURSES ON LANGUAGE TESTING AND ASSESSMENT

    Directory of Open Access Journals (Sweden)

    Olha Kvasova

    2016-12-01

    Full Text Available The paper considers the theoretical underpinnings and practices of designing courses on language testing and assessment for pre-service FL teacher training. The author analyses definitions of assessment literacy offered in the studies of world experts including teaching content and objectives of such long implemented courses. She further reasons the urgent need in introducing courses on language testing and assessment in Ukrainian universities; specifies the goal of the courses which lies in training student teachers in developing quality tests and administering assessments on the outset of their teaching career; outlines the content area to be covered in the course placing emphasis on its being based on professional needs; specifies course objectives such as building students’ awareness of key concepts and principles of language testing, developing ability to critically analyze available ready-made tests and make decisions about their fitting particular assessment needs, building skills to develop own or adapt ready-made tests and tailor them to the educational context; discusses preconditions of efficient running and attaining good outcomes of such courses which, in her view, are predetermined by traditionally high standards of teaching language pedagogy in Ukraine. An innovative structure of the course based on principles of testing cycle as well as interactive and constructivist methods of teaching language testing and assessment to student teachers are offered in the article.

  4. The detection of the methylated Wif-1 gene is more accurate than a fecal occult blood test for colorectal cancer screening

    KAUST Repository

    Amiot, Aurelien

    2014-07-15

    Background: The clinical benefit of guaiac fecal occult blood tests (FOBT) is now well established for colorectal cancer screening. Growing evidence has demonstrated that epigenetic modifications and fecal microbiota changes, also known as dysbiosis, are associated with CRC pathogenesis and might be used as surrogate markers of CRC. Patients and Methods: We performed a cross-sectional study that included all consecutive subjects that were referred (from 2003 to 2007) for screening colonoscopies. Prior to colonoscopy, effluents (fresh stools, sera-S and urine-U) were harvested and FOBTs performed. Methylation levels were measured in stools, S and U for 3 genes (Wif1, ALX-4, and Vimentin) selected from a panel of 63 genes; Kras mutations and seven dominant and subdominant bacterial populations in stools were quantified. Calibration was assessed with the Hosmer-Lemeshow chi-square, and discrimination was determined by calculating the C-statistic (Area Under Curve) and Net Reclassification Improvement index. Results: There were 247 individuals (mean age 60.8±12.4 years, 52% of males) in the study group, and 90 (36%) of these individuals were patients with advanced polyps or invasive adenocarcinomas. A multivariate model adjusted for age and FOBT led to a C-statistic of 0.83 [0.77-0.88]. After supplementary sequential (one-by-one) adjustment, Wif-1 methylation (S or U) and fecal microbiota dysbiosis led to increases of the C-statistic to 0.90 [0.84-0.94] (p = 0.02) and 0.81 [0.74-0.86] (p = 0.49), respectively. When adjusted jointly for FOBT and Wif-1 methylation or fecal microbiota dysbiosis, the increase of the C-statistic was even more significant (0.91 and 0.85, p<0.001 and p = 0.10, respectively). Conclusion: The detection of methylated Wif-1 in either S or U has a higher performance accuracy compared to guaiac FOBT for advanced colorectal neoplasia screening. Conversely, fecal microbiota dysbiosis detection was not more accurate. Blood and urine testing could be

  5. The detection of the methylated Wif-1 gene is more accurate than a fecal occult blood test for colorectal cancer screening

    KAUST Repository

    Amiot, Aurelien; Mansour, Hicham; Baumgaertner, Isabelle; Delchier, Jean-Charles; Tournigand, Christophe; Furet, Jean-Pierre; Carrau, Jean-Pierre; Canoui-Poitrine, Florence; Sobhani, Iradj

    2014-01-01

    Background: The clinical benefit of guaiac fecal occult blood tests (FOBT) is now well established for colorectal cancer screening. Growing evidence has demonstrated that epigenetic modifications and fecal microbiota changes, also known as dysbiosis, are associated with CRC pathogenesis and might be used as surrogate markers of CRC. Patients and Methods: We performed a cross-sectional study that included all consecutive subjects that were referred (from 2003 to 2007) for screening colonoscopies. Prior to colonoscopy, effluents (fresh stools, sera-S and urine-U) were harvested and FOBTs performed. Methylation levels were measured in stools, S and U for 3 genes (Wif1, ALX-4, and Vimentin) selected from a panel of 63 genes; Kras mutations and seven dominant and subdominant bacterial populations in stools were quantified. Calibration was assessed with the Hosmer-Lemeshow chi-square, and discrimination was determined by calculating the C-statistic (Area Under Curve) and Net Reclassification Improvement index. Results: There were 247 individuals (mean age 60.8±12.4 years, 52% of males) in the study group, and 90 (36%) of these individuals were patients with advanced polyps or invasive adenocarcinomas. A multivariate model adjusted for age and FOBT led to a C-statistic of 0.83 [0.77-0.88]. After supplementary sequential (one-by-one) adjustment, Wif-1 methylation (S or U) and fecal microbiota dysbiosis led to increases of the C-statistic to 0.90 [0.84-0.94] (p = 0.02) and 0.81 [0.74-0.86] (p = 0.49), respectively. When adjusted jointly for FOBT and Wif-1 methylation or fecal microbiota dysbiosis, the increase of the C-statistic was even more significant (0.91 and 0.85, p<0.001 and p = 0.10, respectively). Conclusion: The detection of methylated Wif-1 in either S or U has a higher performance accuracy compared to guaiac FOBT for advanced colorectal neoplasia screening. Conversely, fecal microbiota dysbiosis detection was not more accurate. Blood and urine testing could be

  6. The detection of the methylated Wif-1 gene is more accurate than a fecal occult blood test for colorectal cancer screening.

    Directory of Open Access Journals (Sweden)

    Aurelien Amiot

    Full Text Available The clinical benefit of guaiac fecal occult blood tests (FOBT is now well established for colorectal cancer screening. Growing evidence has demonstrated that epigenetic modifications and fecal microbiota changes, also known as dysbiosis, are associated with CRC pathogenesis and might be used as surrogate markers of CRC.We performed a cross-sectional study that included all consecutive subjects that were referred (from 2003 to 2007 for screening colonoscopies. Prior to colonoscopy, effluents (fresh stools, sera-S and urine-U were harvested and FOBTs performed. Methylation levels were measured in stools, S and U for 3 genes (Wif1, ALX-4, and Vimentin selected from a panel of 63 genes; Kras mutations and seven dominant and subdominant bacterial populations in stools were quantified. Calibration was assessed with the Hosmer-Lemeshow chi-square, and discrimination was determined by calculating the C-statistic (Area Under Curve and Net Reclassification Improvement index.There were 247 individuals (mean age 60.8±12.4 years, 52% of males in the study group, and 90 (36% of these individuals were patients with advanced polyps or invasive adenocarcinomas. A multivariate model adjusted for age and FOBT led to a C-statistic of 0.83 [0.77-0.88]. After supplementary sequential (one-by-one adjustment, Wif-1 methylation (S or U and fecal microbiota dysbiosis led to increases of the C-statistic to 0.90 [0.84-0.94] (p = 0.02 and 0.81 [0.74-0.86] (p = 0.49, respectively. When adjusted jointly for FOBT and Wif-1 methylation or fecal microbiota dysbiosis, the increase of the C-statistic was even more significant (0.91 and 0.85, p<0.001 and p = 0.10, respectively.The detection of methylated Wif-1 in either S or U has a higher performance accuracy compared to guaiac FOBT for advanced colorectal neoplasia screening. Conversely, fecal microbiota dysbiosis detection was not more accurate. Blood and urine testing could be used in those individuals reluctant to

  7. Accurate determination of antenna directivity

    DEFF Research Database (Denmark)

    Dich, Mikael

    1997-01-01

    The derivation of a formula for accurate estimation of the total radiated power from a transmitting antenna for which the radiated power density is known in a finite number of points on the far-field sphere is presented. The main application of the formula is determination of directivity from power......-pattern measurements. The derivation is based on the theory of spherical wave expansion of electromagnetic fields, which also establishes a simple criterion for the required number of samples of the power density. An array antenna consisting of Hertzian dipoles is used to test the accuracy and rate of convergence...

  8. Test Bench Development for Femur Stability Assessment

    Directory of Open Access Journals (Sweden)

    Samuel SANCHEZ-CABALLERO

    2015-01-01

    Full Text Available This paper shows the design and development of a test bench for humanfemurs. The main uses of this test bench will run from artificial femurs comparisonwith real femurs, to join stability assessment after bone a fracture repair. Amongthis uses is specially designed for condylar fractures testing. The test bench isdeveloped from a self-made existing tensile/compression testing machine. Thedesign procedure is supported by a literature review about the bone mechanicalbehavior and composition generally and the knee joint performance and repairparticularly. On the basis of this review, the machine was designed to simulate theadduction and abduction movements of the joint. The magnitudes to be measuredare: the compression force, the bone displacement (vertical and the knee jointrotation

  9. An Accurate Method for Inferring Relatedness in Large Datasets of Unphased Genotypes via an Embedded Likelihood-Ratio Test

    KAUST Repository

    Rodriguez, Jesse M.; Batzoglou, Serafim; Bercovici, Sivan

    2013-01-01

    , accurate and efficient detection of hidden relatedness becomes a challenge. To enable disease-mapping studies of increasingly large cohorts, a fast and accurate method to detect IBD segments is required. We present PARENTE, a novel method for detecting

  10. On the assessment of usability testing methods for children

    NARCIS (Netherlands)

    Markopoulos, P.; Bekker, M.M.

    2003-01-01

    The paper motivates the need to acquire methodological knowledge for involving children as test users in usability testing. It introduces a methodological framework for delineating comparative assessments of usability testing methods for children participants. This framework consists in three

  11. Accurate and fast creep test for viscoelastic fluids using disk-probe-type and quadrupole-arrangement-type electromagnetically spinning systems

    Science.gov (United States)

    Hirano, Taichi; Sakai, Keiji

    2017-07-01

    Viscoelasticity is a unique characteristic of soft materials and describes its dynamic response to mechanical stimulations. A creep test is an experimental method for measuring the strain ratio/rate against an applied stress, thereby assessing the viscoelasticity of the materials. We propose two advanced experimental systems suitable for the creep test, adopting our original electromagnetically spinning (EMS) technique. This technique can apply a constant torque by a noncontact mechanism, thereby allowing more sensitive and rapid measurements. The viscosity and elasticity of a semidilute wormlike micellar solution were determined using two setups, and the consistency between the results was assessed.

  12. The most frequently used tests for assessing executive functions in aging

    Directory of Open Access Journals (Sweden)

    Camila de Assis Faria

    Full Text Available There are numerous neuropsychological tests for assessing executive functions in aging, which vary according to the different domains assessed. OBJECTIVE: To present a systematic review of the most frequently used instruments for assessing executive functions in older adults with different educational levels in clinical and experimental research. METHODS: We searched for articles published in the last five years, using the PubMed database with the following terms: "neuropsychological tests", "executive functions", and "mild cognitive impairment". There was no language restriction. RESULTS: 25 articles fulfilled all the inclusion criteria. The seven neuropsychological tests most frequently used to evaluate executive functions in aging were: [1] Trail Making Test (TMT Form B; [2] Verbal Fluency Test (VFT - F, A and S; [3] VFT Animals category; [4] Clock Drawing Test (CDT; [5] Digits Forward and Backward subtests (WAIS-R or WAIS-III; [6] Stroop Test; and [7] Wisconsin Card Sorting Test (WCST and its variants. The domains of executive functions most frequently assessed were: mental flexibility, verbal fluency, planning, working memory, and inhibitory control. CONCLUSION: The study identified the tests and domains of executive functions most frequently used in the last five years by research groups worldwide to evaluate older adults. These results can direct future research and help build evaluation protocols for assessing executive functions, taking into account the different educational levels and socio-demographic profiles of older adults in Brazil.

  13. Environmental Assessment for the LGF Spill Test Facility at Frenchman Flat, Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Patton, S.E.; Novo, M.G.; Shinn, J.H.

    1986-04-01

    The LGF Spill Test Facility at Frenchman Flat, Nevada Test Site, is being constructed by the United States Department of Energy (DOE). In this Environmental Assessment, environmental consequences of spilling hazardous materials in the Frenchman Flat basin are evaluated and mitigations and recommendations are stated in order to protect natural resources and reduce land-use impacts. Guidelines and restrictions concerning spill-test procedures will be determined by the LGF Test Facility Operations Manager and DOE based on toxicity documentation for the test material, provided by the user, and mitigations imposed by the Environmental Assessment. In addition to Spill Test Facility operational procedures, certain assumptions have been made in preparation of this document: no materials will be considered for testing that have cumulative, long-term persistence in the environment; spill tests will consist of releases of 15 min or less; and sufficient time will be allowed between tests for recovery of natural resources. Geographic limits to downwind concentrations of spill materials were primarily determined from meteorological data, human occupational exposure standards to hazardous materials and previous spill tests. These limits were established using maximum spill scenarios and environmental impacts are discussed as worst case scenarios; however, spill-test series will begin with smaller spills, gradually increasing in size after the impacts of the initial tests have been evaluated.

  14. Environmental Assessment for the LGF Spill Test Facility at Frenchman Flat, Nevada Test Site

    International Nuclear Information System (INIS)

    Patton, S.E.; Novo, M.G.; Shinn, J.H.

    1986-04-01

    The LGF Spill Test Facility at Frenchman Flat, Nevada Test Site, is being constructed by the United States Department of Energy (DOE). In this Environmental Assessment, environmental consequences of spilling hazardous materials in the Frenchman Flat basin are evaluated and mitigations and recommendations are stated in order to protect natural resources and reduce land-use impacts. Guidelines and restrictions concerning spill-test procedures will be determined by the LGF Test Facility Operations Manager and DOE based on toxicity documentation for the test material, provided by the user, and mitigations imposed by the Environmental Assessment. In addition to Spill Test Facility operational procedures, certain assumptions have been made in preparation of this document: no materials will be considered for testing that have cumulative, long-term persistence in the environment; spill tests will consist of releases of 15 min or less; and sufficient time will be allowed between tests for recovery of natural resources. Geographic limits to downwind concentrations of spill materials were primarily determined from meteorological data, human occupational exposure standards to hazardous materials and previous spill tests. These limits were established using maximum spill scenarios and environmental impacts are discussed as worst case scenarios; however, spill-test series will begin with smaller spills, gradually increasing in size after the impacts of the initial tests have been evaluated

  15. Turning education into action: Impact of a collective social education approach to improve nurses' ability to recognize and accurately assess delirium in hospitalized older patients.

    Science.gov (United States)

    Travers, Catherine; Henderson, Amanda; Graham, Fred; Beattie, Elizabeth

    2018-03-01

    Although cognitive impairment including dementia and delirium is common in older hospital patients, it is not well recognized or managed by hospital staff, potentially resulting in adverse events. This paper describes, and reports on the impact of a collective social education approach to improving both nurses' knowledge of, and screening for delirium. Thirty-four experienced nurses from six hospital wards, became Cognition Champions (CogChamps) to lead their wards in a collective social education process about cognitive impairment and the assessment of delirium. At the outset, the CogChamps were provided with comprehensive education about dementia and delirium from a multidisciplinary team of clinicians. Their knowledge was assessed to ascertain they had the requisite understanding to engage in education as a collective social process, namely, with each other and their local teams. Following this, they developed ward specific Action Plans in collaboration with their teams aimed at educating and evaluating ward nurses' ability to accurately assess and care for patients for delirium. The plans were implemented over five months. The broader nursing teams' knowledge was assessed, together with their ability to accurately assess patients for delirium. Each ward implemented their Action Plan to varying degrees and key achievements included the education of a majority of ward nurses about delirium and the certification of the majority as competent to assess patients for delirium using the Confusion Assessment Method. Two wards collected pre-and post-audit data that demonstrated a substantial improvement in delirium screening rates. The education process led by CogChamps and supported by educators and clinical experts provides an example of successfully educating nurses about delirium and improving screening rates of patients for delirium. ACTRN 12617000563369. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. How many standard area diagram sets are needed for accurate disease severity assessment

    Science.gov (United States)

    Standard area diagram sets (SADs) are widely used in plant pathology: a rater estimates disease severity by comparing an unknown sample to actual severities in the SADs and interpolates an estimate as accurately as possible (although some SADs have been developed for categorizing disease too). Most ...

  17. Pancreatic exocrine function testing

    International Nuclear Information System (INIS)

    Goff, J.S.

    1981-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and para-aminobenzoic acid bound to a dipeptide. Of all these tests the secretin stimulation test is the most accurate and reliable if done by experienced personnel. However, the indirect tests are simpler to do and appear to be comparable to the secretin test at detecting pancreatic exocrine insufficiency. These indirect tests are becoming clinically available and clinicians should familiarize themselves with the strengths and weaknesses of each

  18. Perceived Physician-informed Weight Status Predicts Accurate Weight Self-Perception and Weight Self-Regulation in Low-income, African American Women.

    Science.gov (United States)

    Harris, Charlie L; Strayhorn, Gregory; Moore, Sandra; Goldman, Brian; Martin, Michelle Y

    2016-01-01

    Obese African American women under-appraise their body mass index (BMI) classification and report fewer weight loss attempts than women who accurately appraise their weight status. This cross-sectional study examined whether physician-informed weight status could predict weight self-perception and weight self-regulation strategies in obese women. A convenience sample of 118 low-income women completed a survey assessing demographic characteristics, comorbidities, weight self-perception, and weight self-regulation strategies. BMI was calculated during nurse triage. Binary logistic regression models were performed to test hypotheses. The odds of obese accurate appraisers having been informed about their weight status were six times greater than those of under-appraisers. The odds of those using an "approach" self-regulation strategy having been physician-informed were four times greater compared with those using an "avoidance" strategy. Physicians are uniquely positioned to influence accurate weight self-perception and adaptive weight self-regulation strategies in underserved women, reducing their risk for obesity-related morbidity.

  19. Availability of periodically tested systems

    International Nuclear Information System (INIS)

    Signoret, J.P.

    1979-01-01

    There is at the present time a need in accurate models to asess the availability of periodically tested stand-by systems. This paper shows how to improve the well known 'saw-tooth curve' model in order to take into account various reliability parameters. A model is developed to assess the pointwise and the mean availabilities of periodically tested stand-by systems. Exact and approxination formulae are given. In addition, the model developed herein leads to optimize the test interval in order to minimize the mean unavailability. A safety diesel in a nuclear power plant is given as an example

  20. Is an alcoholic fixative fluid used for manual liquid-based cytology accurate to perform HPV tests?

    Directory of Open Access Journals (Sweden)

    Garbar C

    2011-12-01

    Full Text Available Christian Garbar1, Corinne Mascaux1, Philippe De Graeve2, Philippe Delvenne31Department of Biopathology, Institute Jean Godinot, Reims Cedex, France; 2Centre de Pathologie des Coteaux, Toulouse, France; 3Department of Pathology, University of Liege, Tour de Pathologie, Domaine Universitaire du Sart Tilman, Liège, BelgiumAbstract: In Europe, the alternative centrifuge method of liquid-based cytology is widely used in cervical screening. Turbitec® (Labonord SAS, Templemars, France is a centrifuge method of liquid-based cytology using an alcoholic fixative fluid, Easyfix® (Labonord. It is now well accepted that the association of liquid-based cytology and human papillomavirus test is indissociable of cervical screening. The aim of this work was to demonstrate that Easyfix alcoholic fluid is reliable to perform Hybrid Capture® 2 (QIAGEN SAS, Courtaboeuf, France. In this study, 75 patients with colposcopy for cervical lesions served as gold standard. A sample was collected, at random, for Easyfix fixative cytological fluid and for Digene Cervical Sampler (QIAGEN. The results of Hybrid Capture 2 (with relative light unit >1 showed no statistical difference, a positive Spearman’s correlation (r = 0.82, P < 0.0001, and a kappa value of 0.87 (excellent agreement between the two fluids. It was concluded that Easyfix is accurate to use in human papillomavirus tests with Hybrid Capture 2.Keywords: human papillomavirus, hybrid capture 2, Turbitec®, cervix cytology, liquid-based cytology

  1. Assessing difference between classical test theory and item ...

    African Journals Online (AJOL)

    Assessing difference between classical test theory and item response theory methods in scoring primary four multiple choice objective test items. ... All research participants were ranked on the CTT number correct scores and the corresponding IRT item pattern scores from their performance on the PRISMADAT. Wilcoxon ...

  2. Managing industrial risk--having a tested and proven system to prevent and assess risk.

    Science.gov (United States)

    Heller, Stephen

    2006-03-17

    Some relatively easy techniques exist to improve the risk picture/profile to aid in preventing losses. Today with the advent of computer system resources, focusing on specific aspects of risk through systematic scoring and comparison, the risk analysis can be relatively easy to achieve. Techniques like these demonstrate how working experience and common sense can be combined mathematically into a flexible risk management tool or risk model for analyzing risk. The risk assessment methodology provided by companies today is no longer the ideas and practices of one group or even one company. It is reflective of the practice of many companies, as well as the ideas and expertise of academia and government regulators. The use of multi-criteria decision making (MCDM) techniques for making critical decisions has been recognized for many years for a variety of purposes. In today's computer age, the easy accessing and user-friendly nature for using these techniques, makes them a favorable choice for use in the risk assessment environment. The new user of these methodologies should find many ideas directly applicable to his or her needs when approaching risk decision making. The user should find their ideas readily adapted, with slight modification, to accurately reflect a specific situation using MCDM techniques. This makes them an attractive feature for use in assessment and risk modeling. The main advantage of decision making techniques, such as MCDM, is that in the early stages of a risk assessment, accurate data on industrial risk, and failures are lacking. In most cases, it is still insufficient to perform a thorough risk assessment using purely statistical concepts. The practical advantages towards deviating from strict data-driven protocol seem to outweigh the drawbacks. Industry failure data often comes at a high cost when a loss occurs. We can benefit from this unfortunate acquisition of data through the continuous refining of our decisions by incorporating this new

  3. General approach for accurate resonance analysis in transformer windings

    NARCIS (Netherlands)

    Popov, M.

    2018-01-01

    In this paper, resonance effects in transformer windings are thoroughly investigated and analyzed. The resonance is determined by making use of an accurate approach based on the application of the impedance matrix of a transformer winding. The method is validated by a test coil and the numerical

  4. Counseling and Testing: What Counselors Need to Know about State Laws on Assessment and Testing

    Science.gov (United States)

    Naugle, Kim A.

    2009-01-01

    This article discusses testing in counseling, the history of psychology's attempts to restrict access to testing, and the potential impact on the public. Counselors are encouraged to obtain appropriate training in assessment and to understand that testing is not only consistent with fair testing policies but also essential for ethical practice.…

  5. Seeing and Being Seen: Predictors of Accurate Perceptions about Classmates’ Relationships

    Science.gov (United States)

    Neal, Jennifer Watling; Neal, Zachary P.; Cappella, Elise

    2015-01-01

    This study examines predictors of observer accuracy (i.e. seeing) and target accuracy (i.e. being seen) in perceptions of classmates’ relationships in a predominantly African American sample of 420 second through fourth graders (ages 7 – 11). Girls, children in higher grades, and children in smaller classrooms were more accurate observers. Targets (i.e. pairs of children) were more accurately observed when they occurred in smaller classrooms of higher grades and involved same-sex, high-popularity, and similar-popularity children. Moreover, relationships between pairs of girls were more accurately observed than relationships between pairs of boys. As a set, these findings suggest the importance of both observer and target characteristics for children’s accurate perceptions of classroom relationships. Moreover, the substantial variation in observer accuracy and target accuracy has methodological implications for both peer-reported assessments of classroom relationships and the use of stochastic actor-based models to understand peer selection and socialization processes. PMID:26347582

  6. Kauai Test Facility hazards assessment document

    Energy Technology Data Exchange (ETDEWEB)

    Swihart, A

    1995-05-01

    The Department of Energy Order 55003A requires facility-specific hazards assessment be prepared, maintained, and used for emergency planning purposes. This hazards assessment document describes the chemical and radiological hazards associated with the Kauai Test Facility, Barking Sands, Kauai, Hawaii. The Kauai Test Facility`s chemical and radiological inventories were screened according to potential airborne impact to onsite and offsite individuals. The air dispersion model, ALOHA, estimated pollutant concentrations downwind from the source of a release, taking into consideration the toxicological and physical characteristics of the release site, the atmospheric conditions, and the circumstances of the release. The greatest distance to the Early Severe Health Effects threshold is 4.2 kilometers. The highest emergency classification is a General Emergency at the {open_quotes}Main Complex{close_quotes} and a Site Area Emergency at the Kokole Point Launch Site. The Emergency Planning Zone for the {open_quotes}Main Complex{close_quotes} is 5 kilometers. The Emergency Planning Zone for the Kokole Point Launch Site is the Pacific Missile Range Facility`s site boundary.

  7. Kauai Test Facility hazards assessment document

    International Nuclear Information System (INIS)

    Swihart, A.

    1995-05-01

    The Department of Energy Order 55003A requires facility-specific hazards assessment be prepared, maintained, and used for emergency planning purposes. This hazards assessment document describes the chemical and radiological hazards associated with the Kauai Test Facility, Barking Sands, Kauai, Hawaii. The Kauai Test Facility's chemical and radiological inventories were screened according to potential airborne impact to onsite and offsite individuals. The air dispersion model, ALOHA, estimated pollutant concentrations downwind from the source of a release, taking into consideration the toxicological and physical characteristics of the release site, the atmospheric conditions, and the circumstances of the release. The greatest distance to the Early Severe Health Effects threshold is 4.2 kilometers. The highest emergency classification is a General Emergency at the open-quotes Main Complexclose quotes and a Site Area Emergency at the Kokole Point Launch Site. The Emergency Planning Zone for the open-quotes Main Complexclose quotes is 5 kilometers. The Emergency Planning Zone for the Kokole Point Launch Site is the Pacific Missile Range Facility's site boundary

  8. Mental models accurately predict emotion transitions.

    Science.gov (United States)

    Thornton, Mark A; Tamir, Diana I

    2017-06-06

    Successful social interactions depend on people's ability to predict others' future actions and emotions. People possess many mechanisms for perceiving others' current emotional states, but how might they use this information to predict others' future states? We hypothesized that people might capitalize on an overlooked aspect of affective experience: current emotions predict future emotions. By attending to regularities in emotion transitions, perceivers might develop accurate mental models of others' emotional dynamics. People could then use these mental models of emotion transitions to predict others' future emotions from currently observable emotions. To test this hypothesis, studies 1-3 used data from three extant experience-sampling datasets to establish the actual rates of emotional transitions. We then collected three parallel datasets in which participants rated the transition likelihoods between the same set of emotions. Participants' ratings of emotion transitions predicted others' experienced transitional likelihoods with high accuracy. Study 4 demonstrated that four conceptual dimensions of mental state representation-valence, social impact, rationality, and human mind-inform participants' mental models. Study 5 used 2 million emotion reports on the Experience Project to replicate both of these findings: again people reported accurate models of emotion transitions, and these models were informed by the same four conceptual dimensions. Importantly, neither these conceptual dimensions nor holistic similarity could fully explain participants' accuracy, suggesting that their mental models contain accurate information about emotion dynamics above and beyond what might be predicted by static emotion knowledge alone.

  9. Mental models accurately predict emotion transitions

    Science.gov (United States)

    Thornton, Mark A.; Tamir, Diana I.

    2017-01-01

    Successful social interactions depend on people’s ability to predict others’ future actions and emotions. People possess many mechanisms for perceiving others’ current emotional states, but how might they use this information to predict others’ future states? We hypothesized that people might capitalize on an overlooked aspect of affective experience: current emotions predict future emotions. By attending to regularities in emotion transitions, perceivers might develop accurate mental models of others’ emotional dynamics. People could then use these mental models of emotion transitions to predict others’ future emotions from currently observable emotions. To test this hypothesis, studies 1–3 used data from three extant experience-sampling datasets to establish the actual rates of emotional transitions. We then collected three parallel datasets in which participants rated the transition likelihoods between the same set of emotions. Participants’ ratings of emotion transitions predicted others’ experienced transitional likelihoods with high accuracy. Study 4 demonstrated that four conceptual dimensions of mental state representation—valence, social impact, rationality, and human mind—inform participants’ mental models. Study 5 used 2 million emotion reports on the Experience Project to replicate both of these findings: again people reported accurate models of emotion transitions, and these models were informed by the same four conceptual dimensions. Importantly, neither these conceptual dimensions nor holistic similarity could fully explain participants’ accuracy, suggesting that their mental models contain accurate information about emotion dynamics above and beyond what might be predicted by static emotion knowledge alone. PMID:28533373

  10. Testing Trends: Considerations for Choosing and Using Assessments

    Science.gov (United States)

    Woods, Julie Rowland

    2015-01-01

    While federal law requires students to be tested in math, English-language arts and science in particular grades, states are still struggling to mount the resources and expertise necessary to fully implement college and career readiness standards, let alone new assessments aligned to these higher standards. New assessments are not only more…

  11. Assessing Fatigue in Late-Midlife

    DEFF Research Database (Denmark)

    Fieo, Robert A; Mortensen, Erik Lykke; Lund, Rikke

    2014-01-01

    Previous methods examining the Multiple Fatigue Inventory-20 (MFI-20) fatigue questionnaire have been limited to classical test theory, for example, factor analytic approaches. We employed modern test theory to further strengthen the construct validity of the MFI-20 fatigue in a sample of healthy...... the interpretive power of the MFI-20, allowing for the identification of the most optimal scales. Poorly performing items were more easily identified, and person ability was assessed more accurately....

  12. Charging and discharging tests for obtaining an accurate dynamic electro-thermal model of high power lithium-ion pack system for hybrid and EV applications

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Camacho, Oscar Mauricio Forero; Nørgård, Per Bromand

    2013-01-01

    This paper presents a battery test platform including two Li-ion battery designed for hybrid and EV applications, and charging/discharging tests under different operating conditions carried out for developing an accurate dynamic electro-thermal model of a high power Li-ion battery pack system....... The aim of the tests has been to study the impact of the battery degradation and to find out the dynamic characteristics of the cells including nonlinear open circuit voltage, series resistance and parallel transient circuit at different charge/discharge currents and cell temperature. An equivalent...... circuit model, based on the runtime battery model and the Thevenin circuit model, with parameters obtained from the tests and depending on SOC, current and temperature has been implemented in MATLAB/Simulink and Power Factory. A good alignment between simulations and measurements has been found....

  13. A new adaptive testing algorithm for shortening health literacy assessments

    Directory of Open Access Journals (Sweden)

    Currie Leanne M

    2011-08-01

    Full Text Available Abstract Background Low health literacy has a detrimental effect on health outcomes, as well as ability to use online health resources. Good health literacy assessment tools must be brief to be adopted in practice; test development from the perspective of item-response theory requires pretesting on large participant populations. Our objective was to develop a novel classification method for developing brief assessment instruments that does not require pretesting on large numbers of research participants, and that would be suitable for computerized adaptive testing. Methods We present a new algorithm that uses principles of measurement decision theory (MDT and Shannon's information theory. As a demonstration, we applied it to a secondary analysis of data sets from two assessment tests: a study that measured patients' familiarity with health terms (52 participants, 60 items and a study that assessed health numeracy (165 participants, 8 items. Results In the familiarity data set, the method correctly classified 88.5% of the subjects, and the average length of test was reduced by about 50%. In the numeracy data set, for a two-class classification scheme, 96.9% of the subjects were correctly classified with a more modest reduction in test length of 35.7%; a three-class scheme correctly classified 93.8% with a 17.7% reduction in test length. Conclusions MDT-based approaches are a promising alternative to approaches based on item-response theory, and are well-suited for computerized adaptive testing in the health domain.

  14. Variable impedance cardiography waveforms: how to evaluate the preejection period more accurately

    International Nuclear Information System (INIS)

    Ermishkin, V V; Kolesnikov, V A; Lukoshkova, E V; Mokh, V P; Sonina, R S; Dupik, N V; Boitsov, S A

    2012-01-01

    Impedance method has been successfully applied for left ventricular function assessment during functional tests. The preejection period (PEP), the interval between Q peak in ECG and a specific mark on impedance cardiogram (ICG) which corresponds to aortic valve opening, is an important indicator of the contractility state and its neurogenic control. Accurate identification of ejection onset by ICG is often problematic, especially in the cardiologic patients, due to peculiar waveforms. An essential obstacle is variability of the shape of the ICG waveform during the exercise and subsequent recovery. A promissing solution can be introduction of an additional pulse sensor placed in the nearby region. We tested this idea in 28 healthy subjects and 6 cardiologic patients using a dual-channel impedance cardiograph for simultaneous recording from the aortic and neck regions, and an earlobe photoplethysmograph. Our findings suggest that incidence of abnormal complicated ICG waveforms increases with age. The combination of standard ICG with ear photoplethysmography and/or additional impedance channel significantly improves the efficacy and accuracy of PEP estimation.

  15. Influential Factors for Accurate Load Prediction in a Demand Response Context

    DEFF Research Database (Denmark)

    Wollsen, Morten Gill; Kjærgaard, Mikkel Baun; Jørgensen, Bo Nørregaard

    2016-01-01

    Accurate prediction of a buildings electricity load is crucial to respond to Demand Response events with an assessable load change. However, previous work on load prediction lacks to consider a wider set of possible data sources. In this paper we study different data scenarios to map the influence....... Next, the time of day that is being predicted greatly influence the prediction which is related to the weather pattern. By presenting these results we hope to improve the modeling of building loads and algorithms for Demand Response planning.......Accurate prediction of a buildings electricity load is crucial to respond to Demand Response events with an assessable load change. However, previous work on load prediction lacks to consider a wider set of possible data sources. In this paper we study different data scenarios to map the influence...

  16. Assessment of Social Information Processing in early childhood: development and initial validation of the Schultz Test of Emotion Processing-Preliminary Version.

    Science.gov (United States)

    Schultz, David; Ambike, Archana; Logie, Sean Kevin; Bohner, Katherine E; Stapleton, Laura M; Vanderwalde, Holly; Min, Christopher B; Betkowski, Jennifer A

    2010-07-01

    Crick and Dodge's (Psychological Bulletin 115:74-101, 1994) social information processing model has proven very useful in guiding research focused on aggressive and peer-rejected children's social-cognitive functioning. Its application to early childhood, however, has been much more limited. The present study responds to this gap by developing and validating a video-based assessment tool appropriate for early childhood, the Schultz Test of Emotion Processing-Preliminary Version (STEP-P). One hundred twenty-five Head Start preschool children participated in the study. More socially competent children more frequently attributed sadness to the victims of provocation and labeled aggressive behaviors as both morally unacceptable and less likely to lead to positive outcomes. More socially competent girls labeled others' emotions more accurately. More disruptive children more frequently produced physically aggressive solutions to social provocations, and more disruptive boys less frequently interpreted social provocations as accidental. The STEP-P holds promise as an assessment tool that assesses knowledge structures related to the SIP model in early childhood.

  17. Virtual reality paced serial assessment test for neuropsychological assessment of a military cohort.

    Science.gov (United States)

    Parsons, Thomas D; Courtney, Christopher; Rizzo, Albert A; Armstrong, Christina; Edwards, Joseph; Reger, Gregory

    2012-01-01

    The assessment and treatment of traumatic brain injury (TBI) has become a difficult challenge for the DoD medical health system. Clinical neuropsychologists are being asked to make statements regarding a soldier's functional skills, ability to return to active duty, and competence in tasks of community living. Given the increasing prevalence of blast injuries to the head, and the fact that many brain injuries may have no external marker of injury, there is need for researching innovative assessment methods in detecting blast-related brain injury. To address these issues, two virtual reality-based Paced Auditory/Visual Serial Addition Tests (PA/VSAT) were developed that involve the participant being immersed in a Virtual Middle Eastern City as serial addition stimuli are presented. This study is an initial validation of the VRPASAT and VRPVSAT as assessments of neurocognitive functioning. When compared to the paper-and-pencil version of the test, as well as the Automated Neuropsychological Assessment Metrics, the VRPASAT and VRPVSAT appear to have enhanced capacity for providing an indication of a participant's performance while immersed in a military relevant simulation.

  18. Specificity and sensitivity assessment of selected nasal provocation testing techniques

    Directory of Open Access Journals (Sweden)

    Edyta Krzych-Fałta

    2016-12-01

    Full Text Available Introduction: Nasal provocation testing involves an allergen-specific local reaction of the nasal mucosa to the administered allergen. Aim: To determine the most objective nasal occlusion assessment technique that could be used in nasal provocation testing. Material and methods : A total of 60 subjects, including 30 patients diagnosed with allergy to common environmental allergens and 30 healthy subjects were enrolled into the study. The method used in the study was a nasal provocation test with an allergen, with a standard dose of a control solution and an allergen (5,000 SBU/ml administered using a calibrated atomizer into both nostrils at room temperature. Early-phase nasal mucosa response in the early phase of the allergic reaction was assessed via acoustic rhinometry, optical rhinometry, nitric oxide in nasal air, and tryptase levels in the nasal lavage fluid. Results : In estimating the homogeneity of the average values, the Levene’s test was used and receiver operating characteristic curves were plotted for all the methods used for assessing the nasal provocation test with an allergen. Statistically significant results were defined for p < 0.05. Of all the objective assessment techniques, the most sensitive and characteristic ones were the optical rhinometry techniques (specificity = 1, sensitivity = 1, AUC = 1, PPV = 1, NPV = 1. Conclusions : The techniques used showed significant differences between the group of patients with allergic rhinitis and the control group. Of all the objective assessment techniques, those most sensitive and characteristic were the optical rhinometry.

  19. Implementation of the Leaching Environmental Assessment Framework

    Science.gov (United States)

    New leaching tests are available in the U.S. for developing more accurate source terms for use in fate and transport models. For beneficial use or disposal, the use of the leaching environmental assessment framework (LEAF) will provide leaching results that reflect field condit...

  20. Assessment of validity with polytrauma Veteran populations.

    Science.gov (United States)

    Bush, Shane S; Bass, Carmela

    2015-01-01

    Veterans with polytrauma have suffered injuries to multiple body parts and organs systems, including the brain. The injuries can generate a triad of physical, neurologic/cognitive, and emotional symptoms. Accurate diagnosis is essential for the treatment of these conditions and for fair allocation of benefits. To accurately diagnose polytrauma disorders and their related problems, clinicians take into account the validity of reported history and symptoms, as well as clinical presentations. The purpose of this article is to describe the assessment of validity with polytrauma Veteran populations. Review of scholarly and other relevant literature and clinical experience are utilized. A multimethod approach to validity assessment that includes objective, standardized measures increases the confidence that can be placed in the accuracy of self-reported symptoms and physical, cognitive, and emotional test results. Due to the multivariate nature of polytrauma and the multiple disciplines that play a role in diagnosis and treatment, an ideal model of validity assessment with polytrauma Veteran populations utilizes neurocognitive, neurological, neuropsychiatric, and behavioral measures of validity. An overview of these validity assessment approaches as applied to polytrauma Veteran populations is presented. Veterans, the VA, and society are best served when accurate diagnoses are made.

  1. Stress Tests and Vulnerability Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Wallner, A. [Austrian Institute of Ecology, Vienna (Austria); Lorenz, P. [ed.; Becker, O. [eds.; Weber, U. [Austrian Institute of Ecology, Vienna (Austria)

    2012-07-01

    After the accident in Fukushima, nuclear safety as topic in anti-nuclear work has gained importance within the Joint Project countries. Therefore, nuclear safety and in particular the activities of the European stress tests were chosen to be the main focus of the Joint Project 2011/2012 as well as the common theme of the national projects. This brochure describes: A) Vulnerability Assessment A critical review of the EU Nuclear Stress Tests in Bulgaria, Hungary, Romania and Ukraine is presented in chapter 1. The review details the main weaknesses identified within the stress tests. Important shortcomings not mentioned in the stress tests reports are also discussed. These evaluations do not claim to be exhaustive, but the findings contribute to a more comprehensive understanding of safety and risk of nuclear power plants in Europe. B) Transparency of the stress tests In chapter 2 the experience of the Joint Project NGOs concerning transparency of the stress tests is presented. The information is not meant to be an evaluation of the transparency of the stress tests in general – such an evaluation is not possible within the scope of this brochure. The evaluation aims to show activities concerning stress tests and how they were conceived by the JP NGOs. Some recommendations for improvement are given. C) Safety focus Within the main topic “nuclear safety” of the Joint Project 2011/2012 the NGOs of each JP country selected a special safety relevant topic, which is/was of particular interest in their country: Bulgaria: The short story of Belene NPP – The victory – Key points of the campaign against the nuclear power plant Romania: Risks of the CANDU reactor design Czech Republic: Results of the conference “Power Plant Load Testing: Safety Inspection or Propaganda?“ Slovakia: Safety deficits of the NPP Mochovce These safety relevant issues are discussed in separate sections within the brochure at hand. (author)

  2. Stress Tests and Vulnerability Assessment

    International Nuclear Information System (INIS)

    Wallner, A.; Lorenz, P.

    2012-01-01

    After the accident in Fukushima, nuclear safety as topic in anti-nuclear work has gained importance within the Joint Project countries. Therefore, nuclear safety and in particular the activities of the European stress tests were chosen to be the main focus of the Joint Project 2011/2012 as well as the common theme of the national projects. This brochure describes: A) Vulnerability Assessment A critical review of the EU Nuclear Stress Tests in Bulgaria, Hungary, Romania and Ukraine is presented in chapter 1. The review details the main weaknesses identified within the stress tests. Important shortcomings not mentioned in the stress tests reports are also discussed. These evaluations do not claim to be exhaustive, but the findings contribute to a more comprehensive understanding of safety and risk of nuclear power plants in Europe. B) Transparency of the stress tests In chapter 2 the experience of the Joint Project NGOs concerning transparency of the stress tests is presented. The information is not meant to be an evaluation of the transparency of the stress tests in general – such an evaluation is not possible within the scope of this brochure. The evaluation aims to show activities concerning stress tests and how they were conceived by the JP NGOs. Some recommendations for improvement are given. C) Safety focus Within the main topic “nuclear safety” of the Joint Project 2011/2012 the NGOs of each JP country selected a special safety relevant topic, which is/was of particular interest in their country: Bulgaria: The short story of Belene NPP – The victory – Key points of the campaign against the nuclear power plant Romania: Risks of the CANDU reactor design Czech Republic: Results of the conference “Power Plant Load Testing: Safety Inspection or Propaganda?“ Slovakia: Safety deficits of the NPP Mochovce These safety relevant issues are discussed in separate sections within the brochure at hand. (author)

  3. Accurate evaluation of exchange fields in finite element micromagnetic solvers

    Science.gov (United States)

    Chang, R.; Escobar, M. A.; Li, S.; Lubarda, M. V.; Lomakin, V.

    2012-04-01

    Quadratic basis functions (QBFs) are implemented for solving the Landau-Lifshitz-Gilbert equation via the finite element method. This involves the introduction of a set of special testing functions compatible with the QBFs for evaluating the Laplacian operator. The results by using QBFs are significantly more accurate than those via linear basis functions. QBF approach leads to significantly more accurate results than conventionally used approaches based on linear basis functions. Importantly QBFs allow reducing the error of computing the exchange field by increasing the mesh density for structured and unstructured meshes. Numerical examples demonstrate the feasibility of the method.

  4. Environmental site assessments should include radon gas testing

    International Nuclear Information System (INIS)

    Nardi, M.A.

    1991-01-01

    There are two emerging influences that will require radon gas testing as part of many property transfers and most site assessments. These requirements come from lending regulators and state legislatures. Fannie Mae and others have developed environmental investigation guidelines for the purchase of environmentally contaminated real estate. These guidelines include radon gas testing for many properties. Several states have enacted laws that require environmental disclosure forms be prepared to ensure that the parties involved in certain real estate transactions are aware of the environmental liabilities that may come with the transfer of property. Indiana has recently enacted legislation that would require the disclosure of the presence of radon gas on many commercial real estate transactions. With more lenders and state governments likely to follow this trend, radon gas testing should be performed during all property transfers and site assessment to protect the parties involved from any legal liabilities

  5. Accurate masking technology for high-resolution powder blasting

    Science.gov (United States)

    Pawlowski, Anne-Gabrielle; Sayah, Abdeljalil; Gijs, Martin A. M.

    2005-07-01

    We have combined eroding 10 µm diameter Al2O3 particles with a new masking technology to realize the smallest and most accurate possible structures by powder blasting. Our masking technology is based on the sequential combination of two polymers:(i) the brittle epoxy resin SU8 for its photosensitivity and (ii) the elastic and thermocurable poly-dimethylsiloxane for its large erosion resistance. We have micropatterned various types of structures with a minimum width of 20 µm for test structures with an aspect ratio of 1, and 50 µm for test structures with an aspect ratio of 2.

  6. Acoustic emission monitoring of the bending under tension test

    DEFF Research Database (Denmark)

    Moghadam, Marcel; Sulaiman, Mohd Hafis Bin; Christiansen, Peter

    2017-01-01

    Preliminary investigations have shown that acoustic emission has promising aspects as an online monitoring technique for assessment of tribological conditions during metal forming as regards to determination of the onset of galling. In the present study the acoustic emission measuring technique h...... in BUT testing has been found to describe the frictional conditions during forming well and to allow for accurate assessment of the limits of lubrication....... been applied for online monitoring of the frictional conditions experienced during Bending Under Tension (BUT) testing. The BUT test emulates the forming conditions experienced when drawing sheet material over a die curvature as in deep drawing processes. Monitoring of the developed acoustic emission...

  7. A creep life assessment method for boiler pipes using small punch creep test

    International Nuclear Information System (INIS)

    Izaki, Toru; Kobayashi, Toshimi; Kusumoto, Junichi; Kanaya, Akihiro

    2009-01-01

    The small punch creep (SPC) test is considered as a highly useful method for creep life assessment for high temperature plant components. SPC uses miniature-sized specimens and does not cause any serious sampling damages, and its assessment accuracy is at a high level. However, in applying the SPC test to the residual creep life assessment of the boiler in service, there are some issues to be studied. In order to apply SPC test to the residual creep life assessment of the 2.25Cr-1Mo steel boiler pipe, the relationship between uniaxial creep stress and the SPC test load has been studied. The virgin material, pre-crept, weldment and service aged samples of 2.25Cr-1Mo steel were tested. It was confirmed that the relationship between uniaxial creep stress and the SPC test load at the same rupture time can be described as a single straight line independent of test conditions and materials. Therefore a life assessment is possible by using SPC test in place of uniaxial creep tests. The creep life assessment using SPC was applied to actual thermal power plant components which are in service.

  8. Performance Assessment of Intelligence, Surveillance, and Reconnaissance (ISR) Enterprise Workflows

    National Research Council Canada - National Science Library

    Hurley, M. B; Jones, P. B

    2007-01-01

    ... on how to assess the performance of these systems. The framework delineates how measurements from laboratory tests, operational experiments, and field deployments can be analyzed to produce accurate, quantitative descriptions of system performance...

  9. Accuracy and Feasibility of Video Analysis for Assessing Hamstring Flexibility and Validity of the Sit-and-Reach Test

    Science.gov (United States)

    Mier, Constance M.

    2011-01-01

    The accuracy of video analysis of the passive straight-leg raise test (PSLR) and the validity of the sit-and-reach test (SR) were tested in 60 men and women. Computer software measured static hip-joint flexion accurately. High within-session reliability of the PSLR was demonstrated (R greater than 0.97). Test-retest (separate days) reliability for…

  10. Lay perceptions of predictive testing for diabetes based on DNA test results versus family history assessment: a focus group study.

    Science.gov (United States)

    Wijdenes-Pijl, Miranda; Dondorp, Wybo J; Timmermans, Danielle Rm; Cornel, Martina C; Henneman, Lidewij

    2011-07-05

    This study assessed lay perceptions of issues related to predictive genetic testing for multifactorial diseases. These perceived issues may differ from the "classic" issues, e.g. autonomy, discrimination, and psychological harm that are considered important in predictive testing for monogenic disorders. In this study, type 2 diabetes was used as an example, and perceptions with regard to predictive testing based on DNA test results and family history assessment were compared. Eight focus group interviews were held with 45 individuals aged 35-70 years with (n = 3) and without (n = 1) a family history of diabetes, mixed groups of these two (n = 2), and diabetes patients (n = 2). All interviews were transcribed and analysed using Atlas-ti. Most participants believed in the ability of a predictive test to identify people at risk for diabetes and to motivate preventive behaviour. Different reasons underlying motivation were considered when comparing DNA test results and a family history risk assessment. A perceived drawback of DNA testing was that diabetes was considered not severe enough for this type of risk assessment. In addition, diabetes family history assessment was not considered useful by some participants, since there are also other risk factors involved, not everyone has a diabetes family history or knows their family history, and it might have a negative influence on family relations. Respect for autonomy of individuals was emphasized more with regard to DNA testing than family history assessment. Other issues such as psychological harm, discrimination, and privacy were only briefly mentioned for both tests. The results suggest that most participants believe a predictive genetic test could be used in the prevention of multifactorial disorders, such as diabetes, but indicate points to consider before both these tests are applied. These considerations differ with regard to the method of assessment (DNA test or obtaining family history) and also differ from

  11. Diagnostic Accuracy of 3 Physical Examination Tests in the Assessment of Hip Microinstability.

    Science.gov (United States)

    Hoppe, Daniel J; Truntzer, Jeremy N; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc R

    2017-11-01

    Hip microinstability is a diagnosis gaining increasing interest. Physical examination tests to identify microinstability have not been objectively investigated using intraoperative confirmation of instability as a reference standard. To determine the test characteristics and diagnostic accuracy of 3 physical examination maneuvers in the detection of hip microinstability. Cohort study (diagnosis); Level of evidence, 2. A review was conducted of 194 consecutive hip arthroscopic procedures performed by a sports medicine surgeon at a tertiary-care academic center. Physical examination findings of interest, including the abduction-hyperextension-external rotation (AB-HEER) test, the prone instability test, and the hyperextension-external rotation (HEER) test, were obtained from prospectively collected data. The reference standard was intraoperative identification of instability based on previously published objective criteria. Test characteristics, including sensitivity, specificity, positive and negative predictive values, and accuracy, were calculated for each test as well as for combinations of tests. A total of 109 patients were included in the analysis. The AB-HEER test was most accurate, with a sensitivity of 80.6% (95% CI, 70.8%-90.5%) and a specificity of 89.4% (95% CI, 80.5%-98.2%). The prone instability test had a low sensitivity (33.9%) but a very high specificity (97.9%). The HEER test performed second in both sensitivity (71.0%) and specificity (85.1%). The combination of multiple tests with positive findings did not yield significantly greater accuracy. All tests had high positive predictive values (range, 86.3%-95.5%) and moderate negative predictive values (range, 52.9%-77.8%). When all 3 tests had positive findings, there was a 95.0% (95% CI, 90.1%-99.9%) chance that the patient had microinstability. The AB-HEER test most accurately predicted hip instability, followed by the HEER test and the prone instability test. However, the high specificity of the

  12. The importance of accurate anatomic assessment for the volumetric analysis of the amygdala

    Directory of Open Access Journals (Sweden)

    L. Bonilha

    2005-03-01

    Full Text Available There is a wide range of values reported in volumetric studies of the amygdala. The use of single plane thick magnetic resonance imaging (MRI may prevent the correct visualization of anatomic landmarks and yield imprecise results. To assess whether there is a difference between volumetric analysis of the amygdala performed with single plane MRI 3-mm slices and with multiplanar analysis of MRI 1-mm slices, we studied healthy subjects and patients with temporal lobe epilepsy. We performed manual delineation of the amygdala on T1-weighted inversion recovery, 3-mm coronal slices and manual delineation of the amygdala on three-dimensional volumetric T1-weighted images with 1-mm slice thickness. The data were compared using a dependent t-test. There was a significant difference between the volumes obtained by the coronal plane-based measurements and the volumes obtained by three-dimensional analysis (P < 0.001. An incorrect estimate of the amygdala volume may preclude a correct analysis of the biological effects of alterations in amygdala volume. Three-dimensional analysis is preferred because it is based on more extensive anatomical assessment and the results are similar to those obtained in post-mortem studies.

  13. A comparison of the efficacy of test-driven learning versus self-assessment learning

    Science.gov (United States)

    He, Xiaohua; Canty, Anne

    2013-01-01

    Objective We compared self-assessment and test-driven learning in two groups of students who studied the same subject. Methods This was a randomized comparative experimental study. The subjects were 259 first-quarter students who were divided into a test group and a self-assessment group based on the methods they used for their learning assessments. We measured the scores and difficulty levels of 3 formal written exams. Students' attitudes toward self-assessment or test-driven learning were surveyed. Results The mean scores of exam 1, exam 2, and a summative exam were 34 (±6), 32 (±8), and 44 (±6) for the self-assessment group, respectively, with corresponding scores of 33 (±6), 33 (±7), 43 (±6) for the test group. There were no significant differences in the mean scores on all 3 tests between the two groups (p > .05). Of the students in the self-assessment group, 64% scored at least 90%, whereas 47% of students in the test group answered at least 90% of the questions correctly (p self-assessment and tests could have a significant impact on students' learning, but each offers different strengths and weaknesses. PMID:23957317

  14. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    Science.gov (United States)

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  15. A self-interaction-free local hybrid functional: Accurate binding energies vis-à-vis accurate ionization potentials from Kohn-Sham eigenvalues

    International Nuclear Information System (INIS)

    Schmidt, Tobias; Kümmel, Stephan; Kraisler, Eli; Makmal, Adi; Kronik, Leeor

    2014-01-01

    We present and test a new approximation for the exchange-correlation (xc) energy of Kohn-Sham density functional theory. It combines exact exchange with a compatible non-local correlation functional. The functional is by construction free of one-electron self-interaction, respects constraints derived from uniform coordinate scaling, and has the correct asymptotic behavior of the xc energy density. It contains one parameter that is not determined ab initio. We investigate whether it is possible to construct a functional that yields accurate binding energies and affords other advantages, specifically Kohn-Sham eigenvalues that reliably reflect ionization potentials. Tests for a set of atoms and small molecules show that within our local-hybrid form accurate binding energies can be achieved by proper optimization of the free parameter in our functional, along with an improvement in dissociation energy curves and in Kohn-Sham eigenvalues. However, the correspondence of the latter to experimental ionization potentials is not yet satisfactory, and if we choose to optimize their prediction, a rather different value of the functional's parameter is obtained. We put this finding in a larger context by discussing similar observations for other functionals and possible directions for further functional development that our findings suggest

  16. Psychological Testing and Psychological Assessment: A Review of Evidence and Issues.

    Science.gov (United States)

    Meyer, Gregory J.; Finn, Stephen E.; Eyde, Lorraine D.; Kay, Gary G.; Moreland, Kevin L.; Dies, Robert R.; Eisman, Elena J.; Kubiszyn, Tom W.; Reed, Geoffrey M.

    2001-01-01

    Summarizes issues associated with psychological assessment, concluding that: psychological test validity is strong and is comparable to medical test validity; distinct assessment methods provide unique sources of information; and clinicians who rely solely on interviews are prone to incomplete understandings. Suggests that multimethod assessment…

  17. Semen analysis and sperm function tests: How much to test?

    Directory of Open Access Journals (Sweden)

    S S Vasan

    2011-01-01

    Full Text Available Semen analysis as an integral part of infertility investigations is taken as a surrogate measure for male fecundity in clinical andrology, male fertility, and pregnancy risk assessments. Clearly, laboratory seminology is still very much in its infancy. In as much as the creation of a conventional semen profile will always represent the foundations of male fertility evaluation, the 5th edition of the World Health Organization (WHO manual is a definitive statement on how such assessments should be carried out and how the quality should be controlled. A major advance in this new edition of the WHO manual, resolving the most salient critique of previous editions, is the development of the first well-defined reference ranges for semen analysis based on the analysis of over 1900 recent fathers. The methodology used in the assessment of the usual variables in semen analysis is described, as are many of the less common, but very valuable, sperm function tests. Sperm function testing is used to determine if the sperm have the biologic capacity to perform the tasks necessary to reach and fertilize ova and ultimately result in live births. A variety of tests are available to evaluate different aspects of these functions. To accurately use these functional assays, the clinician must understand what the tests measure, what the indications are for the assays, and how to interpret the results to direct further testing or patient management.

  18. What Is the Role of Paired Rapid Plasma Reagin Testing (Simultaneous Testing of Acute and Convalescent Samples) in the Diagnosis of Repeat Syphilis and the Follow-up of Syphilis?

    Science.gov (United States)

    Kenyon, Chris R; Osbak, Kara Krista; Van Esbroek, Marjan; Lynen, Lutgarde; Crucitti, Tania

    2018-01-01

    Repeat syphilis is playing an increasing role in syphilis transmission in several populations. The assessment of repeat syphilis and response to treatment depends on accurately measuring intraindividual changes in non-treponemal tests. For a 0- to 6-month delta rapid plasma reagin (RPR) to be determined by routine individual RPR testing, samples are tested 6 months apart with differences in reagent batches, environmental conditions, and observers all leading to measurement errors. We hypothesized that conducting paired RPR testing (simultaneous testing of acute and convalescent samples) would enable a more accurate determination of delta RPR compared with individual testing. A total of 120 study participants with a new diagnosis of syphilis were followed up at 0, 3, 6, 9, 12, 18, and 24 months, with RPR testing performed via individual testing at each study visit and at any suspected repeat syphilis. Rapid plasma reagin paired testing was performed on samples from 0 and 6 months and at any suspected repeat syphilis. The quantitative agreement ±1 dilution among paired and individual testing was 97.2%. There was no difference in the proportion with serofast status at 6 months: 21 (19.4%) and 19 (17.6%) according to paired and individual testing, respectively (P = 0.726). There was no statistically significant difference between 0- and 6-month delta RPR as determined by paired and individual testing in predicting seroresponse at 12 months (86.1% and 91.6% agreement with 12-month serofast/nonserofast classification, respectively; P = 0.262). In our setting, individual testing performed equally well compared with paired testing. Follow-up of syphilis will remain onerous for the patient and the health care provider until new tests that can more accurately assess the response to therapy and repeat syphilis/treatment failure are developed.

  19. Property transfer assessments should include radon gas testing

    International Nuclear Information System (INIS)

    Nardi, M.A.

    1992-01-01

    There are two emerging influences that will require radon gas testing as part of many property transfers and most environmental assessments. These requirements come from lending regulators and state legislatures and affect single family, multifamily, and commercial properties. Fannie Mae and others have developed environmental investigation guidelines for protection from long term legal liabilities in the purchase of environmentally contaminated real estate. These guidelines include radon gas testing for many properties. Several states have enacted laws that require environmental disclosure forms be prepared to ensure that the parties involved in certain real estate transactions are aware of the environmental liabilities that may come with the transfer of property. Indiana has recently enacted legislation that would require the disclosure of the presence of radon gas on many commercial real estate transactions. With more banks and state governments following this trend, radon gas testing should be performed during all property transfers and environmental assessments to protect the parties involved from any long term legal liabilities

  20. Testing of the structural evaluation test unit

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Bobbe, J.G.

    1995-01-01

    In the evaluation of the safety of radioactive material transportation it is important to consider the response of Type B packages to environments more severe than that prescribed by the hypothetical accident sequence in Title 10 Part 71 of the Code of Federal Regulations (NRC 1995). The impact event in this sequence is a 9-meter drop onto an essentially unyielding target, resulting in an impact velocity of 13.4 m/s. The behavior of 9 packages when subjected to impacts more severe than this is not well known. It is the purpose of this program to evaluate the structural response of a test package to these environments. Several types of structural response are considered. Of primary importance is the behavior of the package containment boundary, including the bolted closure and 0-rings. Other areas of concern are loss of shielding capability due to lead slump and the deceleration loading of package contents, that may cause damage to them. This type of information is essential for conducting accurate risk assessments on the transportation of radioactive materials. Currently very conservative estimates of the loss of package protection are used in these assessments. This paper will summarize the results of a regulatory impact test and three extra-regulatory impact tests on a sample package

  1. The Remote Food Photography Method accurately estimates dry powdered foods—the source of calories for many infants

    Science.gov (United States)

    Duhé, Abby F.; Gilmore, L. Anne; Burton, Jeffrey H.; Martin, Corby K.; Redman, Leanne M.

    2016-01-01

    Background Infant formula is a major source of nutrition for infants with over half of all infants in the United States consuming infant formula exclusively or in combination with breast milk. The energy in infant powdered formula is derived from the powder and not the water making it necessary to develop methods that can accurately estimate the amount of powder used prior to reconstitution. Objective To assess the use of the Remote Food Photography Method (RFPM) to accurately estimate the weight of infant powdered formula before reconstitution among the standard serving sizes. Methods For each serving size (1-scoop, 2-scoop, 3-scoop, and 4-scoop), a set of seven test bottles and photographs were prepared including the recommended gram weight of powdered formula of the respective serving size by the manufacturer, three bottles and photographs containing 15%, 10%, and 5% less powdered formula than recommended, and three bottles and photographs containing 5%, 10%, and 15% more powdered formula than recommended (n=28). Ratio estimates of the test photographs as compared to standard photographs were obtained using standard RFPM analysis procedures. The ratio estimates and the United States Department of Agriculture (USDA) data tables were used to generate food and nutrient information to provide the RFPM estimates. Statistical Analyses Performed Equivalence testing using the two one-sided t- test (TOST) approach was used to determine equivalence between the actual gram weights and the RFPM estimated weights for all samples, within each serving size, and within under-prepared and over-prepared bottles. Results For all bottles, the gram weights estimated by the RFPM were within 5% equivalence bounds with a slight under-estimation of 0.05 g (90% CI [−0.49, 0.40]; p<0.001) and mean percent error ranging between 0.32% and 1.58% among the four serving sizes. Conclusion The maximum observed mean error was an overestimation of 1.58% of powdered formula by the RFPM under

  2. The economic value of accurate wind power forecasting to utilities

    Energy Technology Data Exchange (ETDEWEB)

    Watson, S J [Rutherford Appleton Lab., Oxfordshire (United Kingdom); Giebel, G; Joensen, A [Risoe National Lab., Dept. of Wind Energy and Atmospheric Physics, Roskilde (Denmark)

    1999-03-01

    With increasing penetrations of wind power, the need for accurate forecasting is becoming ever more important. Wind power is by its very nature intermittent. For utility schedulers this presents its own problems particularly when the penetration of wind power capacity in a grid reaches a significant level (>20%). However, using accurate forecasts of wind power at wind farm sites, schedulers are able to plan the operation of conventional power capacity to accommodate the fluctuating demands of consumers and wind farm output. The results of a study to assess the value of forecasting at several potential wind farm sites in the UK and in the US state of Iowa using the Reading University/Rutherford Appleton Laboratory National Grid Model (NGM) are presented. The results are assessed for different types of wind power forecasting, namely: persistence, optimised numerical weather prediction or perfect forecasting. In particular, it will shown how the NGM has been used to assess the value of numerical weather prediction forecasts from the Danish Meteorological Institute model, HIRLAM, and the US Nested Grid Model, which have been `site tailored` by the use of the linearized flow model WA{sup s}P and by various Model output Statistics (MOS) and autoregressive techniques. (au)

  3. Enhance pump reliability through improved inservice testing

    International Nuclear Information System (INIS)

    Healy, J.J.

    1990-01-01

    EPRI has undertaken a study to assess the effectiveness of existing testing programs to accurately monitor and predict performance changes before either pump performance degrades or an actual failure occurs. Anticipated changes in inservice testing techniques are directed towards enhancing the validity of test data, ensuring its repeatability, and avoiding deterioration of the pump assembly. There is a new-found interest in test programs of all types that has occurred, in part, because of an increase in reported pump degradation and pump failure. Inservice testing of pumps, which has long been a basis for assuring operability, has apparently produced an opposite effect; namely, the appearance of a reduction in reliability

  4. Advanced Test Reactor outage risk assessment

    International Nuclear Information System (INIS)

    Thatcher, T.A.; Atkinson, S.A.

    1997-01-01

    Beginning in 1997, risk assessment was performed for each Advanced Test Reactor (ATR) outage aiding the coordination of plant configuration and work activities (maintenance, construction projects, etc.) to minimize the risk of reactor fuel damage and to improve defense-in-depth. The risk assessment activities move beyond simply meeting Technical Safety Requirements to increase the awareness of risk sensitive configurations, to focus increased attention on the higher risk activities, and to seek cost-effective design or operational changes that reduce risk. A detailed probabilistic risk assessment (PRA) had been performed to assess the risk of fuel damage during shutdown operations including heavy load handling. This resulted in several design changes to improve safety; however, evaluation of individual outages had not been performed previously and many risk insights were not being utilized in outage planning. The shutdown PRA provided the necessary framework for assessing relative and absolute risk levels and assessing defense-in-depth. Guidelines were written identifying combinations of equipment outages to avoid. Screening criteria were developed for the selection of work activities to receive review. Tabulation of inherent and work-related initiating events and their relative risk level versus plant mode has aided identification of the risk level the scheduled work involves. Preoutage reviews are conducted and post-outage risk assessment is documented to summarize the positive and negative aspects of the outage with regard to risk. The risk for the outage is compared to the risk level that would result from optimal scheduling of the work to be performed and to baseline or average past performance

  5. Accurate calibration of test mass displacement in the LIGO interferometers

    Energy Technology Data Exchange (ETDEWEB)

    Goetz, E [University of Michigan, Ann Arbor, MI 48109 (United States); Savage, R L Jr; Garofoli, J; Kawabe, K; Landry, M [LIGO Hanford Observatory, Richland, WA 99352 (United States); Gonzalez, G; Kissel, J; Sung, M [Louisiana State University, Baton Rouge, LA 70803 (United States); Hirose, E [Syracuse University, Syracuse, NY 13244 (United States); Kalmus, P [Columbia University, New York, NY 10027 (United States); O' Reilly, B; Stuver, A [LIGO Livingston Observatory, Livingston, LA 70754 (United States); Siemens, X, E-mail: egoetz@umich.ed, E-mail: savage_r@ligo-wa.caltech.ed [University of Wisconsin-Milwaukee, Milwaukee, WI 53201 (United States)

    2010-04-21

    We describe three fundamentally different methods we have applied to calibrate the test mass displacement actuators to search for systematic errors in the calibration of the LIGO gravitational-wave detectors. The actuation frequencies tested range from 90 Hz to 1 kHz and the actuation amplitudes range from 10{sup -6} m to 10{sup -18} m. For each of the four test mass actuators measured, the weighted mean coefficient over all frequencies for each technique deviates from the average actuation coefficient for all three techniques by less than 4%. This result indicates that systematic errors in the calibration of the responses of the LIGO detectors to differential length variations are within the stated uncertainties.

  6. Accurate calibration of test mass displacement in the LIGO interferometers

    International Nuclear Information System (INIS)

    Goetz, E; Savage, R L Jr; Garofoli, J; Kawabe, K; Landry, M; Gonzalez, G; Kissel, J; Sung, M; Hirose, E; Kalmus, P; O'Reilly, B; Stuver, A; Siemens, X

    2010-01-01

    We describe three fundamentally different methods we have applied to calibrate the test mass displacement actuators to search for systematic errors in the calibration of the LIGO gravitational-wave detectors. The actuation frequencies tested range from 90 Hz to 1 kHz and the actuation amplitudes range from 10 -6 m to 10 -18 m. For each of the four test mass actuators measured, the weighted mean coefficient over all frequencies for each technique deviates from the average actuation coefficient for all three techniques by less than 4%. This result indicates that systematic errors in the calibration of the responses of the LIGO detectors to differential length variations are within the stated uncertainties.

  7. Accurate, Fast and Cost-Effective Diagnostic Test for Monosomy 1p36 Using Real-Time Quantitative PCR

    Directory of Open Access Journals (Sweden)

    Pricila da Silva Cunha

    2014-01-01

    Full Text Available Monosomy 1p36 is considered the most common subtelomeric deletion syndrome in humans and it accounts for 0.5–0.7% of all the cases of idiopathic intellectual disability. The molecular diagnosis is often made by microarray-based comparative genomic hybridization (aCGH, which has the drawback of being a high-cost technique. However, patients with classic monosomy 1p36 share some typical clinical characteristics that, together with its common prevalence, justify the development of a less expensive, targeted diagnostic method. In this study, we developed a simple, rapid, and inexpensive real-time quantitative PCR (qPCR assay for targeted diagnosis of monosomy 1p36, easily accessible for low-budget laboratories in developing countries. For this, we have chosen two target genes which are deleted in the majority of patients with monosomy 1p36: PRKCZ and SKI. In total, 39 patients previously diagnosed with monosomy 1p36 by aCGH, fluorescent in situ hybridization (FISH, and/or multiplex ligation-dependent probe amplification (MLPA all tested positive on our qPCR assay. By simultaneously using these two genes we have been able to detect 1p36 deletions with 100% sensitivity and 100% specificity. We conclude that qPCR of PRKCZ and SKI is a fast and accurate diagnostic test for monosomy 1p36, costing less than 10 US dollars in reagent costs.

  8. Assessment of resampling methods for causality testing: A note on the US inflation behavior

    Science.gov (United States)

    Kyrtsou, Catherine; Kugiumtzis, Dimitris; Diks, Cees

    2017-01-01

    Different resampling methods for the null hypothesis of no Granger causality are assessed in the setting of multivariate time series, taking into account that the driving-response coupling is conditioned on the other observed variables. As appropriate test statistic for this setting, the partial transfer entropy (PTE), an information and model-free measure, is used. Two resampling techniques, time-shifted surrogates and the stationary bootstrap, are combined with three independence settings (giving a total of six resampling methods), all approximating the null hypothesis of no Granger causality. In these three settings, the level of dependence is changed, while the conditioning variables remain intact. The empirical null distribution of the PTE, as the surrogate and bootstrapped time series become more independent, is examined along with the size and power of the respective tests. Additionally, we consider a seventh resampling method by contemporaneously resampling the driving and the response time series using the stationary bootstrap. Although this case does not comply with the no causality hypothesis, one can obtain an accurate sampling distribution for the mean of the test statistic since its value is zero under H0. Results indicate that as the resampling setting gets more independent, the test becomes more conservative. Finally, we conclude with a real application. More specifically, we investigate the causal links among the growth rates for the US CPI, money supply and crude oil. Based on the PTE and the seven resampling methods, we consistently find that changes in crude oil cause inflation conditioning on money supply in the post-1986 period. However this relationship cannot be explained on the basis of traditional cost-push mechanisms. PMID:28708870

  9. Assessment of resampling methods for causality testing: A note on the US inflation behavior.

    Science.gov (United States)

    Papana, Angeliki; Kyrtsou, Catherine; Kugiumtzis, Dimitris; Diks, Cees

    2017-01-01

    Different resampling methods for the null hypothesis of no Granger causality are assessed in the setting of multivariate time series, taking into account that the driving-response coupling is conditioned on the other observed variables. As appropriate test statistic for this setting, the partial transfer entropy (PTE), an information and model-free measure, is used. Two resampling techniques, time-shifted surrogates and the stationary bootstrap, are combined with three independence settings (giving a total of six resampling methods), all approximating the null hypothesis of no Granger causality. In these three settings, the level of dependence is changed, while the conditioning variables remain intact. The empirical null distribution of the PTE, as the surrogate and bootstrapped time series become more independent, is examined along with the size and power of the respective tests. Additionally, we consider a seventh resampling method by contemporaneously resampling the driving and the response time series using the stationary bootstrap. Although this case does not comply with the no causality hypothesis, one can obtain an accurate sampling distribution for the mean of the test statistic since its value is zero under H0. Results indicate that as the resampling setting gets more independent, the test becomes more conservative. Finally, we conclude with a real application. More specifically, we investigate the causal links among the growth rates for the US CPI, money supply and crude oil. Based on the PTE and the seven resampling methods, we consistently find that changes in crude oil cause inflation conditioning on money supply in the post-1986 period. However this relationship cannot be explained on the basis of traditional cost-push mechanisms.

  10. Assessing Believability

    DEFF Research Database (Denmark)

    Togelius, Julian; Yannakakis, Georgios N.; Karakovskiy, Sergey

    2012-01-01

    (or at least complementary) assessment might be made by an external observer that does not participate in the game, through comparing and ranking the performance of human and non-human agents playing a game. This assessment philosophy was embodied in the Turing Test Track of the recent Mario AI......We discuss what it means for a non-player character (NPC) to be believable or human-like, and how we can accurately assess believability. We argue that participatory observation, where the human assessing believability takes part in the game, is prone to distortion effects. For many games, a fairer...... Championship, where non-expert bystanders evaluated the human-likeness of several agents and humans playing a version of Super Mario Bros. We analyze the results of this competition. Finally, we discuss the possibilities for forming models of believability and of maximizing believability through adjusting game...

  11. Lay perceptions of predictive testing for diabetes based on DNA test results versus family history assessment: a focus group study

    Directory of Open Access Journals (Sweden)

    Cornel Martina C

    2011-07-01

    Full Text Available Abstract Background This study assessed lay perceptions of issues related to predictive genetic testing for multifactorial diseases. These perceived issues may differ from the "classic" issues, e.g. autonomy, discrimination, and psychological harm that are considered important in predictive testing for monogenic disorders. In this study, type 2 diabetes was used as an example, and perceptions with regard to predictive testing based on DNA test results and family history assessment were compared. Methods Eight focus group interviews were held with 45 individuals aged 35-70 years with (n = 3 and without (n = 1 a family history of diabetes, mixed groups of these two (n = 2, and diabetes patients (n = 2. All interviews were transcribed and analysed using Atlas-ti. Results Most participants believed in the ability of a predictive test to identify people at risk for diabetes and to motivate preventive behaviour. Different reasons underlying motivation were considered when comparing DNA test results and a family history risk assessment. A perceived drawback of DNA testing was that diabetes was considered not severe enough for this type of risk assessment. In addition, diabetes family history assessment was not considered useful by some participants, since there are also other risk factors involved, not everyone has a diabetes family history or knows their family history, and it might have a negative influence on family relations. Respect for autonomy of individuals was emphasized more with regard to DNA testing than family history assessment. Other issues such as psychological harm, discrimination, and privacy were only briefly mentioned for both tests. Conclusion The results suggest that most participants believe a predictive genetic test could be used in the prevention of multifactorial disorders, such as diabetes, but indicate points to consider before both these tests are applied. These considerations differ with regard to the method of assessment

  12. Chronic obstructive pulmonary disease (COPD) assessment test scores corresponding to modified Medical Research Council grades among COPD patients.

    Science.gov (United States)

    Lee, Chang-Hoon; Lee, Jinwoo; Park, Young Sik; Lee, Sang-Min; Yim, Jae-Joon; Kim, Young Whan; Han, Sung Koo; Yoo, Chul-Gyu

    2015-09-01

    In assigning patients with chronic obstructive pulmonary disease (COPD) to subgroups according to the updated guidelines of the Global Initiative for Chronic Obstructive Lung Disease, discrepancies have been noted between the COPD assessment test (CAT) criteria and modified Medical Research Council (mMRC) criteria. We investigated the determinants of symptom and risk groups and sought to identify a better CAT criterion. This retrospective study included COPD patients seen between June 20, 2012, and December 5, 2012. The CAT score that can accurately predict an mMRC grade ≥ 2 versus COPD patients, the percentages of patients classified into subgroups A, B, C, and D were 24.5%, 47.2%, 4.2%, and 24.1% based on CAT criteria and 49.3%, 22.4%, 8.9%, and 19.4% based on mMRC criteria, respectively. More than 90% of the patients who met the mMRC criteria for the 'more symptoms group' also met the CAT criteria. AUROC and CART analyses suggested that a CAT score ≥ 15 predicted an mMRC grade ≥ 2 more accurately than the current CAT score criterion. During follow-up, patients with CAT scores of 10 to 14 did not have a different risk of exacerbation versus those with CAT scores COPD patients.

  13. A fast algorithm for determining bounds and accurate approximate p-values of the rank product statistic for replicate experiments.

    Science.gov (United States)

    Heskes, Tom; Eisinga, Rob; Breitling, Rainer

    2014-11-21

    The rank product method is a powerful statistical technique for identifying differentially expressed molecules in replicated experiments. A critical issue in molecule selection is accurate calculation of the p-value of the rank product statistic to adequately address multiple testing. Both exact calculation and permutation and gamma approximations have been proposed to determine molecule-level significance. These current approaches have serious drawbacks as they are either computationally burdensome or provide inaccurate estimates in the tail of the p-value distribution. We derive strict lower and upper bounds to the exact p-value along with an accurate approximation that can be used to assess the significance of the rank product statistic in a computationally fast manner. The bounds and the proposed approximation are shown to provide far better accuracy over existing approximate methods in determining tail probabilities, with the slightly conservative upper bound protecting against false positives. We illustrate the proposed method in the context of a recently published analysis on transcriptomic profiling performed in blood. We provide a method to determine upper bounds and accurate approximate p-values of the rank product statistic. The proposed algorithm provides an order of magnitude increase in throughput as compared with current approaches and offers the opportunity to explore new application domains with even larger multiple testing issue. The R code is published in one of the Additional files and is available at http://www.ru.nl/publish/pages/726696/rankprodbounds.zip .

  14. An improved procedure to accurately assess the variability of the exposure to electromagnetic radiation emitted by GSM base station antennas

    International Nuclear Information System (INIS)

    Bechet, Paul; Miclaus, Simona

    2013-01-01

    Long-term human exposure around Global System for Mobile Communications (GSM) base station antennas has not yet been precisely established; this is of interest from human health and epidemiological perspectives. Actual exposure is difficult to assess accurately, mainly because there is a lack of technical information directly from the GSM operators. The in situ measurement standards available at present provide only a worst-case prediction method; the present work goes beyond this and proposes a methodology that, without the need for data from operators, allows a reliable way to express real exposure with a greater accuracy than all other methods proposed to date. The method is based on dual measurements of the signal strengths in the frequency domain and the time domain and takes into consideration the instantaneous traffic in GSM channels. In addition, it allows a channel-individualized exposure assessement, by making possible the separate analysis of the electric field level in the two types of channel of the GSM standard—the traffic channels and the control channels. (paper)

  15. A simple and accurate grading system for orthoiodohippurate renal scans in the assessment of post-transplant renal function

    International Nuclear Information System (INIS)

    Zaki, S.K.; Bretan, P.N.; Go, R.T.; Rehm, P.K.; Streem, S.B.; Novick, A.C.

    1990-01-01

    Orthoiodohippurate renal scanning has proved to be a reliable, noninvasive method for the evaluation and followup of renal allograft function. However, a standardized system for grading renal function with this test is not available. We propose a simple grading system to distinguish the different functional phases of hippurate scanning in renal transplant recipients. This grading system was studied in 138 patients who were evaluated 1 week after renal transplantation. There was a significant correlation between the isotope renographic functional grade and clinical correlates of allograft function such as the serum creatinine level (p = 0.0001), blood urea nitrogen level (p = 0.0001), urine output (p = 0.005) and need for hemodialysis (p = 0.007). We recommend this grading system as a simple and accurate method to interpret orthoiodohippurate renal scans in the evaluation and followup of renal allograft recipients

  16. Computerized Tests. New practical and ethical challenges for Psychological Assessment

    Directory of Open Access Journals (Sweden)

    Gabriela Susana Lozzia

    2013-08-01

    Full Text Available The purpose of this study is to bring the readers in our field of knowledge closer to the new problems and solutions resulting from the application of computer systems to Psychological Assessment. Therefore, this work puts forward a suitable implementation of Computer-based and Internet-delivered Testing, includes a description of the new technologies that can be applied to Psychological Assessment: administration of traditional paper-and-pencil tests through computers, elaboration of automated reports, computerized adaptive tests, automated test construction and automatic generation of items, as well as the specific guidelines and regulations governing the development of each of these areas. This study provides an outline of the current issues connected with the appropriate use of Computerized Tests by way of conclusion and finally encourages psychologists to keep debating and reflecting on these topics.

  17. Prediction of Accurate Mixed Mode Fatigue Crack Growth Curves using the Paris' Law

    Science.gov (United States)

    Sajith, S.; Krishna Murthy, K. S. R.; Robi, P. S.

    2017-12-01

    Accurate information regarding crack growth times and structural strength as a function of the crack size is mandatory in damage tolerance analysis. Various equivalent stress intensity factor (SIF) models are available for prediction of mixed mode fatigue life using the Paris' law. In the present investigation these models have been compared to assess their efficacy in prediction of the life close to the experimental findings as there are no guidelines/suggestions available on selection of these models for accurate and/or conservative predictions of fatigue life. Within the limitations of availability of experimental data and currently available numerical simulation techniques, the results of present study attempts to outline models that would provide accurate and conservative life predictions.

  18. Study on Factors for Accurate Open Circuit Voltage Characterizations in Mn-Type Li-Ion Batteries

    Directory of Open Access Journals (Sweden)

    Natthawuth Somakettarin

    2017-03-01

    Full Text Available Open circuit voltage (OCV of lithium batteries has been of interest since the battery management system (BMS requires an accurate knowledge of the voltage characteristics of any Li-ion batteries. This article presents an OCV characteristic for lithium manganese oxide (LMO batteries under several experimental operating conditions, and discusses factors for accurate OCV determination. A test system is developed for OCV characterization based on the OCV pulse test method. Various factors for the OCV behavior, such as resting period, step-size of the pulse test, testing current amplitude, hysteresis phenomena, and terminal voltage relationship, are investigated and evaluated. To this end, a general OCV model based on state of charge (SOC tracking is developed and validated with satisfactory results.

  19. Testing Human Skin and Respiratory Sensitizers—What Is Good Enough?

    Directory of Open Access Journals (Sweden)

    Anki Malmborg

    2017-01-01

    Full Text Available Alternative methods for accurate in vitro assessment of skin and respiratory sensitizers are urgently needed. Sensitization is a complex biological process that cannot be evaluated accurately using single events or biomarkers, since the information content is too restricted in these measurements. On the contrary, if the tremendous information content harbored in DNA/mRNA could be mined, most complex biological processes could be elucidated. Genomic technologies available today, including transcriptional profiling and next generation sequencing, have the power to decipher sensitization, when used in the right context. Thus, a genomic test platform has been developed, denoted the Genomic Allergen Rapid Detection (GARD assay. Due to the high informational content of the GARD test, accurate predictions of both the skin and respiratory sensitizing capacity of chemicals, have been demonstrated. Based on a matured dendritic cell line, acting as a human-like reporter system, information about potency has also been acquired. Consequently, multiparametric diagnostic technologies are disruptive test principles that can change the way in which the next generation of alternative methods are designed.

  20. Development of a computerized adaptive test for Schizotypy assessment.

    Directory of Open Access Journals (Sweden)

    Eduardo Fonseca-Pedrero

    Full Text Available BACKGROUND: Schizotypal traits in adolescents from the general population represent the behavioral expression of liability for psychotic disorders. Schizotypy assessment in this sector of population has advanced considerably in the last few years; however, it is necessary to incorporate recent advances in psychological and educational measurement. OBJECTIVE: The main goal of this study was to develop a Computerized Adaptive Test (CAT to evaluate schizotypy through "The Oviedo Questionnaire for Schizotypy Assessment" (ESQUIZO-Q, in non-clinical adolescents. METHODS: The final sample consisted of 3,056 participants, 1,469 males, with a mean age of 15.9 years (SD=1.2. RESULTS: The results indicated that the ESQUIZO-Q scores presented adequate psychometric properties under both Classical Test Theory and Item Response Theory. The Information Function estimated using the Gradual Response Model indicated that the item pool effectively assesses schizotypy at the high end of the latent trait. The correlation between the CAT total scores and the paper-and-pencil test was 0.92. The mean number of presented items in the CAT with the standard error fixed at ≤ 0.30 was of 34 items. CONCLUSION: The CAT showed adequate psychometric properties for schizotypy assessment in the general adolescent population. The ESQUIZO-Q adaptive version could be used as a screening method for the detection of adolescents at risk for psychosis in both educational and mental health settings.

  1. Bioavailability assessment of contaminants in soils via respiration and nitrification tests

    International Nuclear Information System (INIS)

    Hund-Rinke, Kerstin; Simon, Markus

    2008-01-01

    For the assessment of contaminated soils ecotoxicological tests are used to estimate the bioavailability of contaminants in soil samples. Terrestrial tests reveal the habitat function of soils, and parameters applied in tests involving microorganisms include respiration activity and potential ammonium oxidation. For such tests, the threshold values needed to assess the results have already been established in guidelines ISO 17155 and ISO 15685. In this paper, we discuss about the respiration activity and potential ammonium oxidation results obtained from a wide variety of soils with different physico-chemical properties and levels of contamination. These results show that microbial respiration and potential ammonium oxidation have different sensitivities to various classes of contaminants. We demonstrated that both organic and inorganic contaminants influence potential ammonium oxidation, whereas microbial respiration is predominantly affected by biodegradable organic contaminants. These differences might be useful for more detailed assessments of soil contamination, leading to different recommended actions depending on which parameter is affected. - The paper provides a further criterion for a more detailed assessment of soil contamination, leading to different recommended actions depending on which parameter is affected

  2. Bioavailability assessment of contaminants in soils via respiration and nitrification tests

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, Kerstin [Fraunhofer Institute for Molecular Biology and Applied Ecology, Auf dem Aberg 1, 57392 Schmallenberg (Germany)], E-mail: kerstin.hund-rinke@ime.fraunhofer.de; Simon, Markus [Fraunhofer Institute for Molecular Biology and Applied Ecology, Auf dem Aberg 1, 57392 Schmallenberg (Germany)], E-mail: markus.simon@ime.fraunhofer.de

    2008-05-15

    For the assessment of contaminated soils ecotoxicological tests are used to estimate the bioavailability of contaminants in soil samples. Terrestrial tests reveal the habitat function of soils, and parameters applied in tests involving microorganisms include respiration activity and potential ammonium oxidation. For such tests, the threshold values needed to assess the results have already been established in guidelines ISO 17155 and ISO 15685. In this paper, we discuss about the respiration activity and potential ammonium oxidation results obtained from a wide variety of soils with different physico-chemical properties and levels of contamination. These results show that microbial respiration and potential ammonium oxidation have different sensitivities to various classes of contaminants. We demonstrated that both organic and inorganic contaminants influence potential ammonium oxidation, whereas microbial respiration is predominantly affected by biodegradable organic contaminants. These differences might be useful for more detailed assessments of soil contamination, leading to different recommended actions depending on which parameter is affected. - The paper provides a further criterion for a more detailed assessment of soil contamination, leading to different recommended actions depending on which parameter is affected.

  3. Rotating Arc Jet Test Model: Time-Accurate Trajectory Heat Flux Replication in a Ground Test Environment

    Science.gov (United States)

    Laub, Bernard; Grinstead, Jay; Dyakonov, Artem; Venkatapathy, Ethiraj

    2011-01-01

    Though arc jet testing has been the proven method employed for development testing and certification of TPS and TPS instrumentation, the operational aspects of arc jets limit testing to selected, but constant, conditions. Flight, on the other hand, produces timevarying entry conditions in which the heat flux increases, peaks, and recedes as a vehicle descends through an atmosphere. As a result, we are unable to "test as we fly." Attempts to replicate the time-dependent aerothermal environment of atmospheric entry by varying the arc jet facility operating conditions during a test have proven to be difficult, expensive, and only partially successful. A promising alternative is to rotate the test model exposed to a constant-condition arc jet flow to yield a time-varying test condition at a point on a test article (Fig. 1). The model shape and rotation rate can be engineered so that the heat flux at a point on the model replicates the predicted profile for a particular point on a flight vehicle. This simple concept will enable, for example, calibration of the TPS sensors on the Mars Science Laboratory (MSL) aeroshell for anticipated flight environments.

  4. Assessment of Replacement Bridge using Proof Load Test

    Science.gov (United States)

    Sundru, Saibabu

    2017-11-01

    This work begins with an overview of the condition assessment of old bridge and explained reasons for demolishing of the bridge. Briefly presented flexural analysis of two stage post-tensioned prestressed concrete girder, which will be replace the old (new bridge). Construction of I-girder and composite girder at first stage and second stage prestressing respectively is explained with figures. Assessment of the load-caring capacity of the one span of the replacement bridge with simple supports using proof load test is presented which is mandatory according to Indian standards. Weighted sand bags were used to load the bridge up to a predetermined service load with impact factor. Deflections of the I-girders of the bridge were measured at selected locations along and across the bridge span and compared with computed values. Linear response was observed during loading and unloading. Considering the load test results, theoretical estimation and criteria as stipulated in codes of practice, it can be inferred that prestressed concrete I-girder bridge span has adequate capacity to carry the loads and hence, deemed to have passed the test.

  5. Accurate dating with radiocarbon from the atom bomb tests

    CSIR Research Space (South Africa)

    Vogel

    2002-09-01

    Full Text Available The artificial radiocarbon produced by the thermonuclear bomb tests in the 1950s and 1960s significantly increased the level of C-14 in the environment. A detailed record of the subsequent changes in the C-14 concentration of the atmosphere can...

  6. The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength.

    Science.gov (United States)

    Gruet, Mathieu; Peyré-Tartaruga, Leonardo Alexandre; Mely, Laurent; Vallier, Jean-Marc

    2016-12-01

    Exercise testing is part of the regular assessment of patients with cystic fibrosis (CF). We aimed to evaluate (1) the convergent validity of the 1-min sit-to-stand (STS) test in CF by investigating its relationships with peak oxygen uptake (peak V̇ O 2 ), quadriceps strength, and quality of life and (2) to compare these associations with those of the 6-min walk test (6MWT). Twenty-five adults with CF (FEV 1 = 59 ± 24%) performed the STS test, the 6MWT, quadriceps strength assessment, and cardiopulmonary exercise test (CPET). Physical activity level, quality of life, and self-esteem were assessed by questionnaires. STS repetitions, 6-min walk distance, quadriceps strength, and peak V̇ O 2 were, respectively, 71 ± 12, 90 ± 10, 93 ± 29, and 62 ± 16% of predicted. The STS test had moderate associations with peak V̇ O 2 (r = 0.56, P = .004), quadriceps strength (r = 0.52, P = .008), and some questionnaire items (eg, perceived physical strength, r = 0.67, P test was strongly associated with oxygen desaturation during CPET (r = 0.80, P test as compared with CPET (P test cannot be used as a replacement for CPET to accurately assess peak exercise capacity in CF. The STS test may have utility in detecting patients with CF who may exhibit a high level of oxygen desaturation during heavy exercise. Further studies should identify the factors contributing to STS performance to confirm the potential interest of STS repetitions × body weight outcome as a useful submaximal exercise parameter in CF. Copyright © 2016 by Daedalus Enterprises.

  7. Diagnostic Performance of a Molecular Test versus Clinician Assessment of Vaginitis.

    Science.gov (United States)

    Schwebke, Jane R; Gaydos, Charlotte A; Nyirjesy, Paul; Paradis, Sonia; Kodsi, Salma; Cooper, Charles K

    2018-06-01

    Vaginitis is a common complaint, diagnosed either empirically or using Amsel's criteria and wet mount microscopy. This study sought to determine characteristics of an investigational test (a molecular test for vaginitis), compared to reference, for detection of bacterial vaginosis, Candida spp., and Trichomonas vaginalis Vaginal specimens from a cross-sectional study were obtained from 1,740 women (≥18 years old), with vaginitis symptoms, during routine clinic visits (across 10 sites in the United States). Specimens were analyzed using a commercial PCR/fluorogenic probe-based investigational test that detects bacterial vaginosis, Candida spp., and Trichomonas vaginalis Clinician diagnosis and in-clinic testing (Amsel's test, potassium hydroxide preparation, and wet mount) were also employed to detect the three vaginitis causes. All testing methods were compared to the respective reference methods (Nugent Gram stain for bacterial vaginosis, detection of the Candida gene its2 , and Trichomonas vaginalis culture). The investigational test, clinician diagnosis, and in-clinic testing were compared to reference methods for bacterial vaginosis, Candida spp., and Trichomonas vaginalis The investigational test resulted in significantly higher sensitivity and negative predictive value than clinician diagnosis or in-clinic testing. In addition, the investigational test showed a statistically higher overall percent agreement with each of the three reference methods than did clinician diagnosis or in-clinic testing. The investigational test showed significantly higher sensitivity for detecting vaginitis, involving more than one cause, than did clinician diagnosis. Taken together, these results suggest that a molecular investigational test can facilitate accurate detection of vaginitis. Copyright © 2018 Schwebke et al.

  8. Construct validity and reliability of automated body reaction test ...

    African Journals Online (AJOL)

    Automated Body Reaction Test (ABRT) is a new device for skills and physical assessment instrument to measure ability on react, move quickly and accurately in accordance with stimulus. A total of 474 subjects aged 7-17 years old were randomly selected for the construct validity (n=330) and reliability (n=144). The ABRT ...

  9. A method for accurate computation of elastic and discrete inelastic scattering transfer matrix

    International Nuclear Information System (INIS)

    Garcia, R.D.M.; Santina, M.D.

    1986-05-01

    A method for accurate computation of elastic and discrete inelastic scattering transfer matrices is discussed. In particular, a partition scheme for the source energy range that avoids integration over intervals containing points where the integrand has discontinuous derivative is developed. Five-figure accurate numerical results are obtained for several test problems with the TRAMA program which incorporates the porposed method. A comparison with numerical results from existing processing codes is also presented. (author) [pt

  10. Reference genes for accurate transcript normalization in citrus genotypes under different experimental conditions.

    Directory of Open Access Journals (Sweden)

    Valéria Mafra

    Full Text Available Real-time reverse transcription PCR (RT-qPCR has emerged as an accurate and widely used technique for expression profiling of selected genes. However, obtaining reliable measurements depends on the selection of appropriate reference genes for gene expression normalization. The aim of this work was to assess the expression stability of 15 candidate genes to determine which set of reference genes is best suited for transcript normalization in citrus in different tissues and organs and leaves challenged with five pathogens (Alternaria alternata, Phytophthora parasitica, Xylella fastidiosa and Candidatus Liberibacter asiaticus. We tested traditional genes used for transcript normalization in citrus and orthologs of Arabidopsis thaliana genes described as superior reference genes based on transcriptome data. geNorm and NormFinder algorithms were used to find the best reference genes to normalize all samples and conditions tested. Additionally, each biotic stress was individually analyzed by geNorm. In general, FBOX (encoding a member of the F-box family and GAPC2 (GAPDH was the most stable candidate gene set assessed under the different conditions and subsets tested, while CYP (cyclophilin, TUB (tubulin and CtP (cathepsin were the least stably expressed genes found. Validation of the best suitable reference genes for normalizing the expression level of the WRKY70 transcription factor in leaves infected with Candidatus Liberibacter asiaticus showed that arbitrary use of reference genes without previous testing could lead to misinterpretation of data. Our results revealed FBOX, SAND (a SAND family protein, GAPC2 and UPL7 (ubiquitin protein ligase 7 to be superior reference genes, and we recommend their use in studies of gene expression in citrus species and relatives. This work constitutes the first systematic analysis for the selection of superior reference genes for transcript normalization in different citrus organs and under biotic stress.

  11. Towards a less costly but accurate test of gastric emptying and small bowel transit

    Energy Technology Data Exchange (ETDEWEB)

    Camilleri, M.; Zinsmeister, A.R.; Greydanus, M.P.; Brown, M.L.; Proano, M. (Mayo Clinic and Foundation, Rochester, MN (USA))

    1991-05-01

    Our aim is to develop a less costly but accurate test of stomach emptying and small bowel transit by utilizing selected scintigraphic observations 1-6 hr after ingestion of a radiolabeled solid meal. These selected data were compared with more detailed analyses that require multiple scans and labor-intensive technical support. A logistic discriminant analysis was used to estimate the sensitivity and specificity of selected summaries of scintigraphic transit measurements. We studied 14 patients with motility disorders (eight neuropathic and six myopathic, confirmed by standard gastrointestinal manometry) and 37 healthy subjects. The patient group had abnormal gastric emptying (GE) and small bowel transit time (SBTT). The proportion of radiolabel retained in the stomach from 2 to 4 hr (GE 2 hr, GE 3 hr, GE 4 hr), as well as the proportion filling the colon at 4 and 6 hr (CF 4 hr, CF 6 hr) were individually able to differentiate health from disease (P less than 0.05 for each). From the logistic discriminant model, an estimated sensitivity of 93% resulted in similar specificities for detailed and selected transit parameters for gastric emptying (range: 62-70%). Similarly, combining selected observations, such as GE 4 hr with CF 6 hr, had a specificity of 76%, which was similar to the specificity of combinations of more detailed analyses. Based on the present studies and future confirmation in a larger number of patients, including those with less severe motility disorders, the 2-, 4-, and 6-hr scans with quantitation of proportions of counts in stomach and colon should provide a useful, relatively inexpensive strategy to identify and monitor motility disorders in clinical and epidemiologic studies.

  12. A simple method for accurate endotracheal placement of an intubation tube in Guinea pigs to assess lung injury following chemical exposure.

    Science.gov (United States)

    Nambiar, M P; Gordon, R K; Moran, T S; Richards, S M; Sciuto, A M

    2007-01-01

    ABSTRACT Guinea pigs are considered as the animal model of choice for toxicology and medical countermeasure studies against chemical warfare agents (CWAs) and toxic organophosphate pesticides because of the low levels of carboxylesterase compared to rats and mice. However, it is difficult to intubate guinea pigs without damaging the larynx to perform CWA inhalation experiments. We describe an easy technique of intubation of guinea pigs for accurate endotracheal placement of the intubation tube. The technique involves a speculum made by cutting the medium-size ear speculum in the midline leaving behind the intact circular connector to the otoscope. Guinea pigs were anesthetized with Telazol/meditomidine, the tongue was pulled using blunt forceps, and an otoscope attached with the specially prepared speculum was inserted gently. Insertion of the speculum raises the epiglottis and restrains the movements of vocal cord, which allows smooth insertion of the metal stylet-reinforced intubation tube. Accurate endotracheal placement of the intubation tube was achieved by measuring the length from the tracheal bifurcation to vocal cord and vocal cord to the upper front teeth. The average length of the trachea in guinea pigs (275 +/- 25 g) was 5.5 +/- 0.2 cm and the distance from the vocal cord to the front teeth was typically 3 cm. Coinciding an intubation tube marked at 6 cm with the upper front teeth accurately places the intubation tube 2.5 cm above the tracheal bifurcation. This simple method of intubation does not disturb the natural flora of the mouth and causes minimum laryngeal damage. It is rapid and reliable, and will be very valuable in inhalation exposure to chemical/biological warfare agents or toxic chemicals to assess respiratory toxicity and develop medical countermeasures.

  13. Field assessment of soil structural quality - a development of the Peerlkamp test

    DEFF Research Database (Denmark)

    Ball, B C; Batey, T; Munkholm, Lars Juhl

    2007-01-01

    properties (bulk density, penetration resistance and porosity) and crop growth. Indicative thresholds of soil management are suggested. The assessment should be viewed as complementary to conventional laboratory assessments of soil structure. Visual soil structure assessment can indicate to the soil......Increased awareness of the role of soil structure in defining the physical fertility or quality of soil has led to the need for a simple assessment relevant to the environmental and economic sustainability of soil productivity. A test is required that is usable by farmer, consultant and researcher...... alike. Here an assessment of soil structure quality (Sq) is described which is based on a visual key linked to criteria chosen to be as objective as possible. The influences of operator, tillage and crop type on Sq value were tested. The test takes 5-15 min per location and enough replicates were...

  14. Tools for the assessment of childhood apraxia of speech.

    Science.gov (United States)

    Gubiani, Marileda Barichello; Pagliarin, Karina Carlesso; Keske-Soares, Marcia

    2015-01-01

    This study systematically reviews the literature on the main tools used to evaluate childhood apraxia of speech (CAS). The search strategy includes Scopus, PubMed, and Embase databases. Empirical studies that used tools for assessing CAS were selected. Articles were selected by two independent researchers. The search retrieved 695 articles, out of which 12 were included in the study. Five tools were identified: Verbal Motor Production Assessment for Children, Dynamic Evaluation of Motor Speech Skill, The Orofacial Praxis Test, Kaufman Speech Praxis Test for Children, and Madison Speech Assessment Protocol. There are few instruments available for CAS assessment and most of them are intended to assess praxis and/or orofacial movements, sequences of orofacial movements, articulation of syllables and phonemes, spontaneous speech, and prosody. There are some tests for assessment and diagnosis of CAS. However, few studies on this topic have been conducted at the national level, as well as protocols to assess and assist in an accurate diagnosis.

  15. Rapid and Accurate Idea Transfer: Presenting Ideas with Concept Maps

    Science.gov (United States)

    2008-07-30

    questions from the Pre-test were included in the Post-test. I. At the end of the day, people in the camps take home about __ taka to feed their families. 2...teachers are not paid regularly. Tuition fees for different classes are 40 to 80 taka (Bangladesh currency) 27 per month which is very high for the...October 26, 2002. 27 In April 2005, exchange rate, one $ = 60 taka . 44 Rapid and Accurate Idea Transfer: CDRL (DI-MIS-807 11 A, 00012 1) Presenting

  16. Determination of the number of software tests using probabilistic safety assessment

    International Nuclear Information System (INIS)

    Kang, H. K.; Seong, T. Y.; Lee, K. Y.

    2000-01-01

    The broader usage of digital equipment in nuclear power plants gives rise to the safety problems of software. The field test should be performed before the software is used in critical applications because it is well known that software shows non-linear response when it is applied to different target systems in different environment. In the case of safety-critical applications, the result of tests contains usually zero failure case and the satisfiable number of tests is hard to be determined. In this paper, we suggests the method to determine the number of software tests without failure using the probabilistic safety assessment. From the result of the probabilistic safety assessment on total system, the desirable unavailability of software is calculated and the number of tests is determined

  17. Leg mass characteristics of accurate and inaccurate kickers--an Australian football perspective.

    Science.gov (United States)

    Hart, Nicolas H; Nimphius, Sophia; Cochrane, Jodie L; Newton, Robert U

    2013-01-01

    Athletic profiling provides valuable information to sport scientists, assisting in the optimal design of strength and conditioning programmes. Understanding the influence these physical characteristics may have on the generation of kicking accuracy is advantageous. The aim of this study was to profile and compare the lower limb mass characteristics of accurate and inaccurate Australian footballers. Thirty-one players were recruited from the Western Australian Football League to perform ten drop punt kicks over 20 metres to a player target. Players were separated into accurate (n = 15) and inaccurate (n = 16) groups, with leg mass characteristics assessed using whole body dual energy x-ray absorptiometry (DXA) scans. Accurate kickers demonstrated significantly greater relative lean mass (P ≤ 0.004) and significantly lower relative fat mass (P ≤ 0.024) across all segments of the kicking and support limbs, while also exhibiting significantly higher intra-limb lean-to-fat mass ratios for all segments across both limbs (P ≤ 0.009). Inaccurate kickers also produced significantly larger asymmetries between limbs than accurate kickers (P ≤ 0.028), showing considerably lower lean mass in their support leg. These results illustrate a difference in leg mass characteristics between accurate and inaccurate kickers, highlighting the potential influence these may have on technical proficiency of the drop punt.

  18. Accurate assessment of adherence: self-report and clinician report vs electronic monitoring of nebulizers.

    Science.gov (United States)

    Daniels, Tracey; Goodacre, Lynne; Sutton, Chris; Pollard, Kim; Conway, Steven; Peckham, Daniel

    2011-08-01

    People with cystic fibrosis have a high treatment burden. While uncertainty remains about individual patient level of adherence to medication, treatment regimens are difficult to tailor, and interventions are difficult to evaluate. Self- and clinician-reported measures are routinely used despite criticism that they overestimate adherence. This study assessed agreement between rates of adherence to prescribed nebulizer treatments when measured by self-report, clinician report, and electronic monitoring suitable for long-term use. Seventy-eight adults with cystic fibrosis were questioned about their adherence to prescribed nebulizer treatments over the previous 3 months. Self-report was compared with clinician report and stored adherence data downloaded from the I-Neb nebulizer system. Adherence measures were expressed as a percentage of the prescribed regimen, bias was estimated by the paired difference in mean (95% CI) patient and clinician reported and actual adherence. Agreement between adherence measures was calculated using intraclass correlation coefficients (95% CI), and disagreements for individuals were displayed using Bland-Altman plots. Patient-identified prescriptions matched the medical record prescription. Median self-reported adherence was 80% (interquartile range, 60%-95%), whereas median adherence measured by nebulizer download was 36% (interquartile range, 5%-84.5%). Nine participants overmedicated and underreported adherence. Median clinician report ranged from 50% to 60%, depending on profession. Extensive discrepancies between self-report and clinician report compared with nebulizer download were identified for individuals. Self- and clinician-reporting of adherence does not provide accurate measurement of adherence when compared with electronic monitoring. Using inaccurate measures has implications for treatment burden, clinician prescribing practices, cost, and accuracy of trial data.

  19. The Role of Alternative Testing Strategies in Environmental Risk Assessment of Engineered Nanomaterials

    OpenAIRE

    Hjorth, Rune; Holden, Patricia; Hansen, Steffen Foss; Colman, Ben; Grieger, Khara; Hendren, Christine

    2017-01-01

    Within toxicology there is a pressure to find new test systems and organisms to replace, reduce and refine animal testing. In nanoecotoxicology the need for alternative testing strategies (ATS) is further emphasized as the validity of tests and risk assessment practices developed for dissolved chemicals are challenged. Nonetheless, standardized whole organism animal testing is still considered the gold standard for environmental risk assessment. Advancing risk analysis of engineered nanomater...

  20. The Danish Dyslexia Test

    DEFF Research Database (Denmark)

    Poulsen, Mads; Elbro, Carsten; Møller, Helene Lykke

    2016-01-01

    Purpose: Dyslexia is a long lasting problem in learning to decode written words accurately and fluently. This definition suggests that dyslexia remains sufficiently constant to be assessed reliably with just one wide-range test across all educational levels. The current study investigated...... this possibility by asking whether students who receive special support in reading differ from other students on the same scale of decoding across all educational levels. Method: Decoding and spelling measures from a newly developed, web-based Danish dyslexia test were taken from 1564 students from Grade 3...... 9. Measures of decoding difficulties were reliably associated with current practices for referral to special support at all educational levels. On average, students receiving special support performed at the 5th percentile of the unselected groups. The results suggest that a wide-range test...

  1. Assessment of strength characteristics of Al2024 ECAP metal using small punch testing

    International Nuclear Information System (INIS)

    Ma, Young Wha; Choi, Jeong Woo; Yoon, Kee Bong; Kim, Seon Hwa

    2006-01-01

    When subjected to severe shear deformation by ECAP, microstructure of Al2024 becomes extremely refined. To measure the strength of that, Small Punch(SP) testing method was adopted as a substitute for the conventional uniaxial tensile testing because the size of material processed by ECAP were limited to ψ12 mm in transverse direction. SP tests were performed with specimens in longitudinal and transverse directions of Al2024 ECAP metal. For comparing the strength values with those assessed by SP tests, uniaxial tensile tests were also conducted with specimens in longitudinal direction. Failure surfaces of the tested SP specimens showed that failure mode was shear deformation and Al2024 ECAP metal has an anisotropy in strength. Thus, conventional equations proposed for assessing the strength characteristics were improper to assess those of Al2024 ECAP metal. In this paper a way of assessing the strength of Al2024 ECAP metal was proposed and was proven to be effective

  2. Assessment of three cuban sites for testing resistance to sugarcane mosaic virus

    Directory of Open Access Journals (Sweden)

    Yaquelin Puchades

    2015-03-01

    Full Text Available Sugarcane mosaic disease is amongst the world’s most important diseases affecting sugarcane worldwide. The objective was to assess the environmental conditions of the sites where the test for SCMV resistance is done. Multi-environment trial Data were analyzed using a Principal Components Analysis Eighteen sugarcane genotypes s were evaluated from the main testing sites in Cuba (Jovellanos, Florida, Mayarí . The information of the climatic conditions was recorded at local weather stations. The assessment of the sites was done by analyzing the main components. Results showed that the testing sites were different from one another, and proved that the environment strongly influences on the mosaic symptom manifestation. PCA was an excellent procedure to assess the testing sites .for SCMV resistance.

  3. Affirmative Psychological Testing and Neurocognitive Assessment with Transgender Adults.

    Science.gov (United States)

    Keo-Meier, Colton L; Fitzgerald, Kara M

    2017-03-01

    Neither consensus on best practice nor validated neuropsychological, intelligence, or personality testing batteries exist for assessment and psychological testing on the transgender population. Historically, assessment has been used in a gate-keeping fashion with transgender clients. There are no firm standards of care when considering the content and appropriateness of evaluations conducted presurgically. These evaluations are discussed in the setting of other presurgical evaluations, with a recommendation to move toward a competency to make a medical decisions model. Additional considerations are discussed, such as effects of transition on mood and how to interpret scores in a field where normative data are often gender stratified. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Assessment of neuro-optometric rehabilitation using the Developmental Eye Movement (DEM) test in adults with acquired brain injury.

    Science.gov (United States)

    Kapoor, Neera; Ciuffreda, Kenneth Joseph

    This pilot study sought to determine the efficacy of using the Developmental Eye Movement (DEM) test in the adult, acquired brain injury (ABI) population to quantify clinically the effects of controlled, laboratory-performed, oculomotor-based vision therapy/vision rehabilitation. Nine adult subjects with mild traumatic brain injury (mTBI) and five with stroke were assessed before and after an eight-week, computer-based, versional oculomotor (fixation, saccades, pursuit, and simulated reading) training program (9.6h total). The protocol incorporated a cross-over, interventional design with and without the addition of auditory feedback regarding two-dimensional eye position. The clinical outcome measure was the Developmental Eye Movement (DEM) test score (ratio, errors) taken before, midway, and immediately following training. For the DEM ratio parameter, improvements were found in 80-89% of the subjects. For the DEM error parameter, improvements were found in 100% of the subjects. Incorporation of the auditory feedback component revealed a trend toward enhanced performance. The findings were similar for both DEM parameters, as well as for incorporation of the auditory feedback, in both diagnostic groups. The results of the present study demonstrated considerable improvements in the DEM test scores following the oculomotor-based training, thus reflecting more time-optimal and accurate saccadic tracking after the training. The DEM test should be considered as another clinical test of global saccadic tracking performance in the ABI population. Copyright © 2017 Spanish General Council of Optometry. All rights reserved.

  5. Item response theory, computerized adaptive testing, and PROMIS: assessment of physical function.

    Science.gov (United States)

    Fries, James F; Witter, James; Rose, Matthias; Cella, David; Khanna, Dinesh; Morgan-DeWitt, Esi

    2014-01-01

    Patient-reported outcome (PRO) questionnaires record health information directly from research participants because observers may not accurately represent the patient perspective. Patient-reported Outcomes Measurement Information System (PROMIS) is a US National Institutes of Health cooperative group charged with bringing PRO to a new level of precision and standardization across diseases by item development and use of item response theory (IRT). With IRT methods, improved items are calibrated on an underlying concept to form an item bank for a "domain" such as physical function (PF). The most informative items can be combined to construct efficient "instruments" such as 10-item or 20-item PF static forms. Each item is calibrated on the basis of the probability that a given person will respond at a given level, and the ability of the item to discriminate people from one another. Tailored forms may cover any desired level of the domain being measured. Computerized adaptive testing (CAT) selects the best items to sharpen the estimate of a person's functional ability, based on prior responses to earlier questions. PROMIS item banks have been improved with experience from several thousand items, and are calibrated on over 21,000 respondents. In areas tested to date, PROMIS PF instruments are superior or equal to Health Assessment Questionnaire and Medical Outcome Study Short Form-36 Survey legacy instruments in clarity, translatability, patient importance, reliability, and sensitivity to change. Precise measures, such as PROMIS, efficiently incorporate patient self-report of health into research, potentially reducing research cost by lowering sample size requirements. The advent of routine IRT applications has the potential to transform PRO measurement.

  6. Lateral Flow Rapid Test for Accurate and Early Diagnosis of Scrub Typhus: A Febrile Illness of Historically Military Importance in the Pacific Rim.

    Science.gov (United States)

    Chao, Chien-Chung; Zhangm, Zhiwen; Weissenberger, Giulia; Chen, Hua-Wei; Ching, Wei-Mei

    2017-03-01

    Scrub typhus (ST) is an infection caused by Orientia tsutsugamushi. Historically, ST was ranked as the second most important arthropod-borne medical problem only behind malaria during World War II and the Vietnam War. The disease occurs mainly in Southeast Asia and has been shown to emerge and reemerge in new areas, implying the increased risk for U.S. military and civilian personnel deployed to these regions. ST can effectively be treated by doxycycline provided the diagnosis is made early, before the development of severe complications. Scrub Typhus Detect is a lateral flow rapid test based on a mixture of recombinant 56-kDa antigens with broad reactivity. The performance of this prototype product was evaluated against indirect immunofluorescence assay, the serological gold standard. Using 249 prospectively collected samples from Thailand, the sensitivity and specificity for IgM was found to be 100% and 92%, respectively, suggesting a high potential of this product for clinical use. This product will provide a user friendly, rapid, and accurate diagnosis of ST for clinicians to provide timely and accurate treatments of deployed personnel. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  7. An accurate nonlinear Monte Carlo collision operator

    International Nuclear Information System (INIS)

    Wang, W.X.; Okamoto, M.; Nakajima, N.; Murakami, S.

    1995-03-01

    A three dimensional nonlinear Monte Carlo collision model is developed based on Coulomb binary collisions with the emphasis both on the accuracy and implementation efficiency. The operator of simple form fulfills particle number, momentum and energy conservation laws, and is equivalent to exact Fokker-Planck operator by correctly reproducing the friction coefficient and diffusion tensor, in addition, can effectively assure small-angle collisions with a binary scattering angle distributed in a limited range near zero. Two highly vectorizable algorithms are designed for its fast implementation. Various test simulations regarding relaxation processes, electrical conductivity, etc. are carried out in velocity space. The test results, which is in good agreement with theory, and timing results on vector computers show that it is practically applicable. The operator may be used for accurately simulating collisional transport problems in magnetized and unmagnetized plasmas. (author)

  8. Structural and functional screening in human induced-pluripotent stem cell-derived cardiomyocytes accurately identifies cardiotoxicity of multiple drug types

    Energy Technology Data Exchange (ETDEWEB)

    Doherty, Kimberly R., E-mail: kimberly.doherty@quintiles.com; Talbert, Dominique R.; Trusk, Patricia B.; Moran, Diarmuid M.; Shell, Scott A.; Bacus, Sarah

    2015-05-15

    Safety pharmacology studies that evaluate new drug entities for potential cardiac liability remain a critical component of drug development. Current studies have shown that in vitro tests utilizing human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CM) may be beneficial for preclinical risk evaluation. We recently demonstrated that an in vitro multi-parameter test panel assessing overall cardiac health and function could accurately reflect the associated clinical cardiotoxicity of 4 FDA-approved targeted oncology agents using hiPS-CM. The present studies expand upon this initial observation to assess whether this in vitro screen could detect cardiotoxicity across multiple drug classes with known clinical cardiac risks. Thus, 24 drugs were examined for their effect on both structural (viability, reactive oxygen species generation, lipid formation, troponin secretion) and functional (beating activity) endpoints in hiPS-CM. Using this screen, the cardiac-safe drugs showed no effects on any of the tests in our panel. However, 16 of 18 compounds with known clinical cardiac risk showed drug-induced changes in hiPS-CM by at least one method. Moreover, when taking into account the Cmax values, these 16 compounds could be further classified depending on whether the effects were structural, functional, or both. Overall, the most sensitive test assessed cardiac beating using the xCELLigence platform (88.9%) while the structural endpoints provided additional insight into the mechanism of cardiotoxicity for several drugs. These studies show that a multi-parameter approach examining both cardiac cell health and function in hiPS-CM provides a comprehensive and robust assessment that can aid in the determination of potential cardiac liability. - Highlights: • 24 drugs were tested for cardiac liability using an in vitro multi-parameter screen. • Changes in beating activity were the most sensitive in predicting cardiac risk. • Structural effects add in

  9. Second-order accurate volume-of-fluid algorithms for tracking material interfaces

    International Nuclear Information System (INIS)

    Pilliod, James Edward; Puckett, Elbridge Gerry

    2004-01-01

    We introduce two new volume-of-fluid interface reconstruction algorithms and compare the accuracy of these algorithms to four other widely used volume-of-fluid interface reconstruction algorithms. We find that when the interface is smooth (e.g., continuous with two continuous derivatives) the new methods are second-order accurate and the other algorithms are first-order accurate. We propose a design criteria for a volume-of-fluid interface reconstruction algorithm to be second-order accurate. Namely, that it reproduce lines in two space dimensions or planes in three space dimensions exactly. We also introduce a second-order, unsplit, volume-of-fluid advection algorithm that is based on a second-order, finite difference method for scalar conservation laws due to Bell, Dawson and Shubin. We test this advection algorithm by modeling several different interface shapes propagating in two simple incompressible flows and compare the results with the standard second-order, operator-split advection algorithm. Although both methods are second-order accurate when the interface is smooth, we find that the unsplit algorithm exhibits noticeably better resolution in regions where the interface has discontinuous derivatives, such as at corners

  10. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment.

    Directory of Open Access Journals (Sweden)

    Aline Guttmann

    Full Text Available In cluster detection of disease, the use of local cluster detection tests (CDTs is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps.

  11. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment

    Science.gov (United States)

    Guttmann, Aline; Li, Xinran; Feschet, Fabien; Gaudart, Jean; Demongeot, Jacques; Boire, Jean-Yves; Ouchchane, Lemlih

    2015-01-01

    In cluster detection of disease, the use of local cluster detection tests (CDTs) is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC) is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps. PMID:26086911

  12. Exploring the relationship between sequence similarity and accurate phylogenetic trees.

    Science.gov (United States)

    Cantarel, Brandi L; Morrison, Hilary G; Pearson, William

    2006-11-01

    We have characterized the relationship between accurate phylogenetic reconstruction and sequence similarity, testing whether high levels of sequence similarity can consistently produce accurate evolutionary trees. We generated protein families with known phylogenies using a modified version of the PAML/EVOLVER program that produces insertions and deletions as well as substitutions. Protein families were evolved over a range of 100-400 point accepted mutations; at these distances 63% of the families shared significant sequence similarity. Protein families were evolved using balanced and unbalanced trees, with ancient or recent radiations. In families sharing statistically significant similarity, about 60% of multiple sequence alignments were 95% identical to true alignments. To compare recovered topologies with true topologies, we used a score that reflects the fraction of clades that were correctly clustered. As expected, the accuracy of the phylogenies was greatest in the least divergent families. About 88% of phylogenies clustered over 80% of clades in families that shared significant sequence similarity, using Bayesian, parsimony, distance, and maximum likelihood methods. However, for protein families with short ancient branches (ancient radiation), only 30% of the most divergent (but statistically significant) families produced accurate phylogenies, and only about 70% of the second most highly conserved families, with median expectation values better than 10(-60), produced accurate trees. These values represent upper bounds on expected tree accuracy for sequences with a simple divergence history; proteins from 700 Giardia families, with a similar range of sequence similarities but considerably more gaps, produced much less accurate trees. For our simulated insertions and deletions, correct multiple sequence alignments did not perform much better than those produced by T-COFFEE, and including sequences with expressed sequence tag-like sequencing errors did not

  13. Marijuana effects on long-term memory assessment and retrieval.

    Science.gov (United States)

    Darley, C F; Tinklenberg, J R; Roth, W T; Vernon, S; Kopell, B S

    1977-05-09

    The ability of 16 college-educated male subjects to recall from long-term memory a series of common facts was tested during intoxication with marijuana extract calibrated to 0.3 mg/kg delta-9-tetrahydrocannabinol and during placebo conditions. The subjects' ability to assess their memory capabilities was then determined by measuring how certain they were about the accuracy of their recall performance and by having them predict their performance on a subsequent recognition test involving the same recall items. Marijuana had no effect on recall or recognition performance. These results do not support the view that marijuana provides access to facts in long-term storage which are inaccessible during non-intoxication. During both marijuana and placebo conditions, subjects could accurately predict their recognition memory performance. Hence, marijuana did not alter the subjects' ability to accurately assess what information resides in long-term memory even though they did not have complete access to that information.

  14. An accurate definition of the status of inactive hepatitis B virus carrier by a combination of biomarkers (FibroTest-ActiTest and viral load.

    Directory of Open Access Journals (Sweden)

    Yen Ngo

    . CONCLUSION: In patients with chronic hepatitis B, a combination of FibroTest-ActiTest and viral load testing accurately defined the prognosis and the inactive carrier status.

  15. Assessment of Attention in Preschoolers

    Science.gov (United States)

    Mahone, E.M.; Schneider, H.E.

    2012-01-01

    In the past two decades, there has been an increased interest in the assessment and treatment of preschool children presenting with concerns about attention problems. This article reviews the research and clinical literature involving assessment of attention and related skills in the preschool years. While inattention among preschoolers is common, symptoms alone do not necessarily indicate a disorder, and most often represent a normal variation in typical preschool child development. Thus, accurate identification of “disordered” attention in preschoolers can be challenging, and development of appropriate, norm-referenced tests of attention for preschoolers is also difficult. The current review suggests that comprehensive assessment of attention and related functions in the preschool child should include thorough review of the child’s history, planned observations, and formal psychometric testing. The three primary methods of psychometric assessment that have been used to characterize attentional functioning in preschool children include performance-based tests, structured caregiver interviews, and rating scales (parent, teacher, and clinician). Among performance-based methods for measurement of attention in the preschool years, tests have been developed to assess sustained attention, selective (focused) attention, span of attention (encoding/manipulation), and (top-down) controlled attention—including freedom from distractibility and set shifting. Many of these tests remain experimental in nature, and review of published methods yields relatively few commercially available, nationally normed tests of attention for preschoolers, and an overall dearth of reliability and validity studies on the available measures. PMID:23090646

  16. The Remote Food Photography Method Accurately Estimates Dry Powdered Foods-The Source of Calories for Many Infants.

    Science.gov (United States)

    Duhé, Abby F; Gilmore, L Anne; Burton, Jeffrey H; Martin, Corby K; Redman, Leanne M

    2016-07-01

    Infant formula is a major source of nutrition for infants, with more than half of all infants in the United States consuming infant formula exclusively or in combination with breast milk. The energy in infant powdered formula is derived from the powder and not the water, making it necessary to develop methods that can accurately estimate the amount of powder used before reconstitution. Our aim was to assess the use of the Remote Food Photography Method to accurately estimate the weight of infant powdered formula before reconstitution among the standard serving sizes. For each serving size (1 scoop, 2 scoops, 3 scoops, and 4 scoops), a set of seven test bottles and photographs were prepared as follow: recommended gram weight of powdered formula of the respective serving size by the manufacturer; three bottles and photographs containing 15%, 10%, and 5% less powdered formula than recommended; and three bottles and photographs containing 5%, 10%, and 15% more powdered formula than recommended (n=28). Ratio estimates of the test photographs as compared to standard photographs were obtained using standard Remote Food Photography Method analysis procedures. The ratio estimates and the US Department of Agriculture data tables were used to generate food and nutrient information to provide the Remote Food Photography Method estimates. Equivalence testing using the two one-sided t tests approach was used to determine equivalence between the actual gram weights and the Remote Food Photography Method estimated weights for all samples, within each serving size, and within underprepared and overprepared bottles. For all bottles, the gram weights estimated by the Remote Food Photography Method were within 5% equivalence bounds with a slight underestimation of 0.05 g (90% CI -0.49 to 0.40; P<0.001) and mean percent error ranging between 0.32% and 1.58% among the four serving sizes. The maximum observed mean error was an overestimation of 1.58% of powdered formula by the Remote

  17. Biaxial testing for nuclear grade graphite by ball on three balls assessment

    International Nuclear Information System (INIS)

    Mohd Reusmaazran Yusof; Yusof Abdullah

    2012-01-01

    Nuclear grade (high-purity) graphite for fuel element and moderator material in Advanced Gas Cooling Reactors (AGR) displays large scatter in strength and a non-linear stress-strain response from the damage accumulation. These responses can be characterized as quasi-brittle behaviour. Current assessments of fracture in core graphite components are based on the linear elastic approximation and thus represent a major assumption. The quasi-brittle behaviour gives challenge to assess the real nuclear graphite component. The selected test method would help to bridge the gap between microscale to macro-scale in real reactor component. The small scale tests presented here can contribute some statistical data to manifests the failure in real component. The evaluation and choice of different solution design of biaxial test will be discussed in this paper. The ball on-three ball test method was used for assessment test follows by numerous of analytical method. The results shown that biaxial strength of the EY9 grade graphite depends on the method used for evaluation. Some of the analytical methods use to calculate biaxial strength were found not to be valid and therefore should not be used to assess the mechanical properties of nuclear graphite. (author)

  18. The TiltMeter app is a novel and accurate measurement tool for the weight bearing lunge test.

    Science.gov (United States)

    Williams, Cylie M; Caserta, Antoni J; Haines, Terry P

    2013-09-01

    The weight bearing lunge test is increasing being used by health care clinicians who treat lower limb and foot pathology. This measure is commonly established accurately and reliably with the use of expensive equipment. This study aims to compare the digital inclinometer with a free app, TiltMeter on an Apple iPhone. This was an intra-rater and inter-rater reliability study. Two raters (novice and experienced) conducted the measurements in both a bent knee and straight leg position to determine the intra-rater and inter-rater reliability. Concurrent validity was also established. Allied health practitioners were recruited as participants from the workplace. A preconditioning stretch was conducted and the ankle range of motion was established with the weight bearing lunge test position with firstly the leg straight and secondly with the knee bent. The measurement device and each participant were randomised during measurement. The intra-rater reliability and inter-rater reliability for the devices and in both positions were all over ICC 0.8 except for one intra-rater measure (Digital inclinometer, novice, ICC 0.65). The inter-rater reliability between the digital inclinometer and the tilmeter was near perfect, ICC 0.96 (CI: 0.898-0.983); Concurrent validity ICC between the two devices was 0.83 (CI: -0.740 to 0.445). The use of the Tiltmeter app on the iPhone is a reliable and inexpensive tool to measure the available ankle range of motion. Health practitioners should use caution in applying these findings to other smart phone equipment if surface areas are not comparable. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  19. Assessment of moral judgment and empathy in young sex offenders: a comparison of clinical judgment and test results.

    Science.gov (United States)

    van Vugt, Eveline; Asscher, Jessica; Hendriks, Jan; Stams, Geert Jan; Bijleveld, Catrien; van der Laan, Peter

    2012-10-01

    Professional decision making in forensic clinical practice may have lifelong consequences for offenders. Although information on moral development is important for prediction of reoffending and referral to adequate treatment, conclusions regarding moral development are still largely based on unstructured clinical judgment instead of assessment instruments. For this study, the authors examined to what extent unstructured clinical judgment of both moral judgment and victim empathy concurred with test results in a group of young sex offenders. Moral judgment was measured with the Sociomoral Reflection Measure-Short Form (SRM-SF), whereas victim empathy was measured with an extended version of the Basic Empathy Scale (BES). No significant associations were found between clinical judgment of moral judgment and the mean scores on the SRM-SF. However, clinical judgment of victim empathy was significantly associated with victim empathy on the Victim Empathy Scale but not consistently in the expected direction. Juvenile sex offenders, who were judged by clinicians to show little victim empathy, displayed lower mean scores on the Victim Empathy Scale than juvenile sex offenders who were evaluated to lack victim empathy or to have intact victim empathy. This study showed unstructured clinical judgment of moral development not to concur with test results. To improve decision-making processes regarding moral development, clinicians are advised to rely on instruments that assess moral development to inform clinical judgment. Further research is needed to examine which predictions are more accurate and to establish the predictive validity of moral development evaluations.

  20. Double Trait Assessment Test Battery for Air Force Pilots

    National Research Council Canada - National Science Library

    Tarnowski, Adam

    1998-01-01

    Building on years of theoretical discussions as well as diagnostic experience in the Polish Air Force Institute of Aviation Medicine, a battery of psychological tests was proposed for the assessment...

  1. MOODLE XML TO IMS QTI ASSESSMENT TEST PORTABILITY ON LEARNING MANAGEMENT SYSTEM

    OpenAIRE

    Kautsar, Irwan Alnarus; Kubota, Shin-Ichiro; Musashi, Yasuo; Sugitani, Kenichi

    2013-01-01

    Learning Management Systems (i.e. LMS) is one of the most popular solutions towards the e-Learning objective in different universities all around the world, where this environments are used to not only deliver contents but to perform assessments, tests and other tasks related to learning. Although, there are popular LMS such as Moodle, and more developed, such as Chamilo, there is no assessment/test portability among their LMS. Each assessment export formats make difficult to transfer well do...

  2. Protocol investigating the clinical utility of an objective measure of activity and attention (QbTest) on diagnostic and treatment decision-making in children and young people with ADHD-'Assessing QbTest Utility in ADHD' (AQUA): a randomised controlled trial.

    Science.gov (United States)

    Hall, Charlotte L; Walker, Gemma M; Valentine, Althea Z; Guo, Boliang; Kaylor-Hughes, Catherine; James, Marilyn; Daley, David; Sayal, Kapil; Hollis, Chris

    2014-12-01

    The National Institute for Health and Care Excellence (NICE) guidelines for attention deficit/hyperactivity disorder (ADHD) state that young people need to have access to the best evidence-based care to improve outcome. The current 'gold standard' ADHD diagnostic assessment combines clinical observation with subjective parent, teacher and self-reports. In routine practice, reports from multiple informants may be unavailable or contradictory, leading to diagnostic uncertainty and delay. The addition of objective tests of attention and activity may help reduce diagnostic uncertainty and delays in initiating treatment leading to improved outcomes. This trial investigates whether providing clinicians with an objective report of levels of attention, impulsivity and activity can lead to an earlier, and more accurate, clinical diagnosis and improved patient outcome. This multisite randomised controlled trial will recruit young people (aged 6-17 years old) who have been referred for an ADHD diagnostic assessment at Child and Adolescent Mental Health Services (CAMHS) and Community Paediatric clinics across England. Routine clinical assessment will be augmented by the QbTest, incorporating a continuous performance test (CPT) and infrared motion tracking of activity. The participant will be randomised into one of two study arms: QbOpen (clinician has immediate access to a QbTest report): QbBlind (report is withheld until the study end). Primary outcomes are time to diagnosis and diagnostic accuracy. Secondary outcomes include clinician's diagnostic confidence and routine clinical outcome measures. Cost-effective analysis will be conducted, alongside a qualitative assessment of the feasibility and acceptability of incorporating QbTest in routine practice. The findings from the study will inform commissioners, clinicians and managers about the feasibility, acceptability, clinical utility and cost-effectiveness of incorporating QbTest into routine diagnostic assessment of young

  3. Testing-Context Analysis: Assessment Is Just Another Part of Language Curriculum Development

    Science.gov (United States)

    Brown, James Dean

    2008-01-01

    In keeping with the theme of the International Language Testing Association/Language Testing Research Colloquium Conference in 2008, "Focusing on the Core: Justifying the Use of Language Assessments to Stakeholders," I define "stakeholder-friendly tests," "defensible testing," and "testing-context analysis."…

  4. Microscopic assessment of bone toughness using scratch tests

    Directory of Open Access Journals (Sweden)

    Amrita Kataruka

    2017-06-01

    Full Text Available Bone is a composite material with five distinct structural levels: collagen molecules, mineralized collagen fibrils, lamellae, osteon and whole bone. However, most fracture testing methods have been limited to the macroscopic scale and there is a need for advanced characterization methods to assess toughness at the osteon level and below. The goal of this investigation is to present a novel framework to measure the fracture properties of bone at the microscopic scale using scratch testing. A rigorous experimental protocol is articulated and applied to examine cortical bone specimens from porcine femurs. The observed fracture behavior is very complex: we observe a strong anisotropy of the response with toughening mechanisms and a competition between plastic flow and brittle fracture. The challenge consists then in applying nonlinear fracture mechanics methods such as the J-integral or the energetic Size Effect Law to quantify the fracture toughness in a rigorous fashion. Our result suggests that mixed-mode fracture is instrumental in determining the fracture resistance. There is also a pronounced coupling between fracture and elasticity. Our methodology opens the door to fracture assessment at multiple structural levels, microscopic and potentially nanometer length scale, due to the scalability of scratch tests.

  5. Predicting Falls in People with Multiple Sclerosis: Fall History Is as Accurate as More Complex Measures

    Directory of Open Access Journals (Sweden)

    Michelle H. Cameron

    2013-01-01

    Full Text Available Background. Many people with MS fall, but the best method for identifying those at increased fall risk is not known. Objective. To compare how accurately fall history, questionnaires, and physical tests predict future falls and injurious falls in people with MS. Methods. 52 people with MS were asked if they had fallen in the past 2 months and the past year. Subjects were also assessed with the Activities-specific Balance Confidence, Falls Efficacy Scale-International, and Multiple Sclerosis Walking Scale-12 questionnaires, the Expanded Disability Status Scale, Timed 25-Foot Walk, and computerized dynamic posturography and recorded their falls daily for the following 6 months with calendars. The ability of baseline assessments to predict future falls was compared using receiver operator curves and logistic regression. Results. All tests individually provided similar fall prediction (area under the curve (AUC 0.60–0.75. A fall in the past year was the best predictor of falls (AUC 0.75, sensitivity 0.89, specificity 0.56 or injurious falls (AUC 0.69, sensitivity 0.96, specificity 0.41 in the following 6 months. Conclusion. Simply asking people with MS if they have fallen in the past year predicts future falls and injurious falls as well as more complex, expensive, or time-consuming approaches.

  6. How accurate are adolescents in portion-size estimation using the computer tool Young Adolescents' Nutrition Assessment on Computer (YANA-C)?

    Science.gov (United States)

    Vereecken, Carine; Dohogne, Sophie; Covents, Marc; Maes, Lea

    2010-06-01

    Computer-administered questionnaires have received increased attention for large-scale population research on nutrition. In Belgium-Flanders, Young Adolescents' Nutrition Assessment on Computer (YANA-C) has been developed. In this tool, standardised photographs are available to assist in portion-size estimation. The purpose of the present study is to assess how accurate adolescents are in estimating portion sizes of food using YANA-C. A convenience sample, aged 11-17 years, estimated the amounts of ten commonly consumed foods (breakfast cereals, French fries, pasta, rice, apple sauce, carrots and peas, crisps, creamy velouté, red cabbage, and peas). Two procedures were followed: (1) short-term recall: adolescents (n 73) self-served their usual portions of the ten foods and estimated the amounts later the same day; (2) real-time perception: adolescents (n 128) estimated two sets (different portions) of pre-weighed portions displayed near the computer. Self-served portions were, on average, 8 % underestimated; significant underestimates were found for breakfast cereals, French fries, peas, and carrots and peas. Spearman's correlations between the self-served and estimated weights varied between 0.51 and 0.84, with an average of 0.72. The kappa statistics were moderate (>0.4) for all but one item. Pre-weighed portions were, on average, 15 % underestimated, with significant underestimates for fourteen of the twenty portions. Photographs of food items can serve as a good aid in ranking subjects; however, to assess the actual intake at a group level, underestimation must be considered.

  7. Towards accurate emergency response behavior

    International Nuclear Information System (INIS)

    Sargent, T.O.

    1981-01-01

    Nuclear reactor operator emergency response behavior has persisted as a training problem through lack of information. The industry needs an accurate definition of operator behavior in adverse stress conditions, and training methods which will produce the desired behavior. Newly assembled information from fifty years of research into human behavior in both high and low stress provides a more accurate definition of appropriate operator response, and supports training methods which will produce the needed control room behavior. The research indicates that operator response in emergencies is divided into two modes, conditioned behavior and knowledge based behavior. Methods which assure accurate conditioned behavior, and provide for the recovery of knowledge based behavior, are described in detail

  8. Seedling imaging analysis and traditional tests to assess okra seed vigor

    OpenAIRE

    Kikuti,Ana Lúcia Pereira; Marcos-Filho,Júlio

    2013-01-01

    Seed vigor testing is an important component of quality control programs adopted by seed industry. The software Seed Vigor Imaging System (SVIS) has been successfully used for seed vigor assessment in different species. The objective of this research was to verify the SVIS efficiency to assess okra seed vigor in comparison to other vigor tests used for this species. Five seed lots of 'Clemson Americano' and four of 'Santa Cruz' were submitted to germination (speed and percentage), cold germin...

  9. Pharmacy students' test-taking motivation-effort on a low-stakes standardized test.

    Science.gov (United States)

    Waskiewicz, Rhonda A

    2011-04-11

    To measure third-year pharmacy students' level of motivation while completing the Pharmacy Curriculum Outcomes Assessment (PCOA) administered as a low-stakes test to better understand use of the PCOA as a measure of student content knowledge. Student motivation was manipulated through an incentive (ie, personal letter from the dean) and a process of statistical motivation filtering. Data were analyzed to determine any differences between the experimental and control groups in PCOA test performance, motivation to perform well, and test performance after filtering for low motivation-effort. Incentivizing students diminished the need for filtering PCOA scores for low effort. Where filtering was used, performance scores improved, providing a more realistic measure of aggregate student performance. To ensure that PCOA scores are an accurate reflection of student knowledge, incentivizing and/or filtering for low motivation-effort among pharmacy students should be considered fundamental best practice when the PCOA is administered as a low-stakes test.

  10. Assessment of power output in jump tests for applicants to a sports sciences degree.

    Science.gov (United States)

    Lara, A J; Abián, J; Alegre, L M; Jiménez, L; Aguado, X

    2006-09-01

    Our study aimed: 1) to describe the jump performance in a population of male applicants to a Faculty of Sports Sciences, 2) to apply different power equations from the literature to assess their accuracy, and 3) to develop a new regression equation from this population. The push off phases of the counter-movement jumps (CMJ) on a force platform of 161 applicants (age: 19+/-2.9 years; weight: 70.4+/-8.3 kg) to a Spanish Faculty of Sports Sciences were recorded and subsequently analyzed. Their hands had to be placed on the hips and the knee angle during the counter movement was not controlled. Each subject had 2 trials to reach a minimum of 29 cm of jump height, and when 2 jumps were performed the best trial was analyzed. Multiple regression analysis was performed to develop a new regression equation. Mean jump height was 34.6+/-4.3 cm, peak vertical force 1 663.9+/-291.1 N and peak power 3524.4+/-562 W. All the equations underestimated power, from 74% (Lewis) to 8% (Sayers). However, there were high and significant correlations between peak power measured on the force platform, and those assessed by the equations. The results of the present study support the development of power equations for specific populations, to achieve more accurate assessments. The power equation from this study [Power = (62.5 x jump height (cm)) + (50.3 x body mass (kg)) 2184.7] can be used accurately in populations of male physical education students.

  11. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Kearny, C.H.

    2001-11-20

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these

  12. Development of the Central Dogma Concept Inventory (CDCI) Assessment Tool

    Science.gov (United States)

    Newman, Dina L.; Snyder, Christopher W.; Fisk, J. Nick; Wright, L. Kate

    2016-01-01

    Scientific teaching requires scientifically constructed, field-tested instruments to accurately evaluate student thinking and gauge teacher effectiveness. We have developed a 23-question, multiple select--format assessment of student understanding of the essential concepts of the central dogma of molecular biology that is appropriate for all…

  13. Discrete sensors distribution for accurate plantar pressure analyses.

    Science.gov (United States)

    Claverie, Laetitia; Ille, Anne; Moretto, Pierre

    2016-12-01

    The aim of this study was to determine the distribution of discrete sensors under the footprint for accurate plantar pressure analyses. For this purpose, two different sensor layouts have been tested and compared, to determine which was the most accurate to monitor plantar pressure with wireless devices in research and/or clinical practice. Ten healthy volunteers participated in the study (age range: 23-58 years). The barycenter of pressures (BoP) determined from the plantar pressure system (W-inshoe®) was compared to the center of pressures (CoP) determined from a force platform (AMTI) in the medial-lateral (ML) and anterior-posterior (AP) directions. Then, the vertical ground reaction force (vGRF) obtained from both W-inshoe® and force platform was compared for both layouts for each subject. The BoP and vGRF determined from the plantar pressure system data showed good correlation (SCC) with those determined from the force platform data, notably for the second sensor organization (ML SCC= 0.95; AP SCC=0.99; vGRF SCC=0.91). The study demonstrates that an adjusted placement of removable sensors is key to accurate plantar pressure analyses. These results are promising for a plantar pressure recording outside clinical or laboratory settings, for long time monitoring, real time feedback or for whatever activity requiring a low-cost system. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Accurate measurement of surface areas of anatomical structures by computer-assisted triangulation of computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Allardice, J.T.; Jacomb-Hood, J.; Abulafi, A.M.; Williams, N.S. (Royal London Hospital (United Kingdom)); Cookson, J.; Dykes, E.; Holman, J. (London Hospital Medical College (United Kingdom))

    1993-05-01

    There is a need for accurate surface area measurement of internal anatomical structures in order to define light dosimetry in adjunctive intraoperative photodynamic therapy (AIOPDT). The authors investigated whether computer-assisted triangulation of serial sections generated by computed tomography (CT) scanning can give an accurate assessment of the surface area of the walls of the true pelvis after anterior resection and before colorectal anastomosis. They show that the technique of paper density tessellation is an acceptable method of measuring the surface areas of phantom objects, with a maximum error of 0.5%, and is used as the gold standard. Computer-assisted triangulation of CT images of standard geometric objects and accurately-constructed pelvic phantoms gives a surface area assessment with a maximum error of 2.5% compared with the gold standard. The CT images of 20 patients' pelves have been analysed by computer-assisted triangulation and this shows the surface area of the walls varies from 143 cm[sup 2] to 392 cm[sup 2]. (Author).

  15. Dynamic gadolinium-enhanced magnetic resonance imaging allows accurate assessment of the synovial inflammatory activity in rheumatoid arthritis knee joints: a comparison with synovial histology

    DEFF Research Database (Denmark)

    Axelsen, Mette Bjørndal; Stoltenberg, M.; Poggenborg, R.

    2012-01-01

    , the average grade of histological synovial inflammation was determined from four biopsies obtained during surgery. A preoperative series of T(1)-weighted dynamic fast low-angle shot (FLASH) MR images was obtained. Parameters characterizing contrast uptake dynamics, including the initial rate of enhancement...... capsule of the knee joint (Precise ROI). Intra- and interreader agreement was assessed using the intra-class correlation coefficient (ICC). Results: The IRE from the Quick ROI and the Precise ROI revealed high correlations to the grade of histological inflammation (Spearman's correlation coefficient (rho......) = 0.70, p = 0.001 and rho = 0.74, p = 0.001, respectively). Intraand inter-reader ICCs were very high (0.93-1.00). No Whole slice parameters were correlated to histology. Conclusion: DCE-MRI provides fast and accurate assessment of synovial inflammation in RA patients. Manual outlining of the joint...

  16. MELCOR 1.8.2 Assessment: IET direct containment heating tests

    Energy Technology Data Exchange (ETDEWEB)

    Kmetyk, L.N.

    1993-10-01

    MELCOR is a fully integrated, engineering-level computer code, being developed at Sandia National Laboratories for the USNRC, that models the entire spectrum of severe accident phenomena in a unified framework for both BWRs and PWRS. As part of an ongoing assessment program, the MELCOR computer code has been used to analyze several of the IET direct containment heating experiments done at 1:10 linear scale in the Surtsey test facility at Sandia and at 1:40 linear scale in the corium-water thermal interactions (CWTI) COREXIT test facility at Argonne National Laboratory. These MELCOR calculations were done as an open post-test study, with both the experimental data and CONTAIN results available to guide the selection of code input. Basecase MELCOR results are compared to test data in order to evaluate the new HPME DCH model recently added in MELCOR version 1.8.2. The effect of various user-input parameters in the HPME model, which define both the initial debris source and the subsequent debris interaction, were investigated in sensitivity studies. In addition, several other non-default input modelling changes involving other MELCOR code packages were required in our IET assessment analyses in order to reproduce the observed experiment behavior. Several calculations were done to identify whether any numeric effects exist in our DCH IET assessment analyses.

  17. EEG INTERFACE MODULE FOR COGNITIVE ASSESSMENT THROUGH NEUROPHYSIOLOGIC TESTS

    Directory of Open Access Journals (Sweden)

    Kundan Lal Verma

    2014-12-01

    Full Text Available The cognitive signal processing is one of the important interdisciplinary field came from areas of life sciences, psychology, psychiatry, engi-neering, mathematics, physics, statistics and many other fields of research. Neurophysiologic tests are utilized to assess and treat brain injury, dementia, neurological conditions, and useful to investigate psychological and psychiatric disorders. This paper presents an ongoing research work on development of EEG interface device based on the principles of cognitive assessments and instrumentation. The method proposed engineering and science of cogni-tive signal processing in case of brain computer in-terface based neurophysiologic tests. The future scope of this study is to build a low cost EEG device for various clinical and pre-clinical applications with specific emphasis to measure the effect of cognitive action on human brain.

  18. Individual Differences in Accurately Judging Personality From Text.

    Science.gov (United States)

    Hall, Judith A; Goh, Jin X; Mast, Marianne Schmid; Hagedorn, Christian

    2016-08-01

    This research examines correlates of accuracy in judging Big Five traits from first-person text excerpts. Participants in six studies were recruited from psychology courses or online. In each study, participants performed a task of judging personality from text and performed other ability tasks and/or filled out questionnaires. Participants who were more accurate in judging personality from text were more likely to be female; had personalities that were more agreeable, conscientious, and feminine, and less neurotic and dominant (all controlling for participant gender); scored higher on empathic concern; self-reported more interest in, and attentiveness to, people's personalities in their daily lives; and reported reading more for pleasure, especially fiction. Accuracy was not associated with SAT scores but had a significant relation to vocabulary knowledge. Accuracy did not correlate with tests of judging personality and emotion based on audiovisual cues. This research is the first to address individual differences in accurate judgment of personality from text, thus adding to the literature on correlates of the good judge of personality. © 2015 Wiley Periodicals, Inc.

  19. The Politics of Testing/Assessment (Or a Chameleon in the Classroom).

    Science.gov (United States)

    Lewis, Anne E.

    A number of political issues are involved in educational testing and the National Assessment of Educational Progress (NAEP). Many school officials are disturbed by the number of tests administered and the information and instructional time lost; they are reluctant to accede to further voluntary testing programs which might duplicate current…

  20. The Stool DNA Test is More Accurate than the Plasma Septin 9 Test in Detecting Colorectal Neoplasia

    Science.gov (United States)

    Ahlquist, David A.; Taylor, William R.; Mahoney, Douglas W.; Zou, Hongzhi; Domanico, Michael; Thibodeau, Stephen N.; Boardman, Lisa A.; Berger, Barry M.; Lidgard, Graham P.

    2014-01-01

    Background & Aims Several noninvasive tests have been developed for colorectal cancer (CRC) screening. We compared the sensitivities of a multi-marker test for stool DNA (sDNA) and a plasma test for methylated Septin 9 (SEPT9) in identifying patients with large adenomas or CRC. Methods We analyzed paired stool and plasma samples from 30 patients with CRC and 22 with large adenomas from Mayo Clinic archives. Stool (n=46) and plasma (n=49) samples from age- and sex-matched patients with normal colonoscopy results were used as controls. The sDNA test is an assay for methylated BMP3, NDRG4, vimentin, and TFPI2; mutant KRAS; the β-actin gene, and quantity of hemoglobin (by the porphyrin method). It was performed blindly at Exact Sciences (Madison WI); the test for SEPT9 was performed at ARUP Laboratories (Salt Lake City UT). Results were considered positive based on the manufacturer's specificity cutoff values of 90% and 89%, respectively. Results The sDNA test detected adenomas (median 2 cm, range 1–5 cm) with 82% sensitivity (95% confidence interval [CI], 60%–95%); SEPT9 had 14% sensitivity (95% CI, 3%–35%; P=.0001). The sDNA test identified patients with CRC with 87% sensitivity (95% CI, 69%–96%); SEPT9 had 60% sensitivity (95% CI, 41%–77%; P=.046). The sDNA test identified patients with stage I–III CRC with 91% sensitivity (95% CI, 71%–99%); SEPT9 had 50% sensitivity (95% CI, 28%–72%; P=.013); for stage IV CRC, sensitivity values were 75% (95% CI, 35%–97%) and 88% (95% CI, 47%–100%), respectively (P=.56). False-positive rates were 7% for the sDNA test and 27% for SEPT9. Conclusions Based on analyses of paired samples, the sDNA test detects non-metastatic CRC and large adenomas with significantly greater levels of sensitivity than the SEPT9 test. These findings might be used to modify approaches for CRC prevention and early detection. PMID:22019796

  1. Testing and assessment of low alloy steel for marine application

    International Nuclear Information System (INIS)

    Amjad, M.; Ahmad, S.; Mahmood, K.; Qureshi, A.H.

    2007-01-01

    This paper is an account of the work carried out during the assessment of low alloy steel (WH-80) for marine application. The relevant acceptance criteria consulted during the process is DEFST AN 02-874 and a standard reference material. Assessment is based on the experimental results of the tests carried out for the steel. Testing comprised of mechanical (tensile, impact and hardness) tests, corrosion (immersion corrosion and stress corrosion cracking) tests, metallography test and weldability (weld joint strength, controlled thermal severity -CTS and Y -Groove) tests undertaken at various testing laboratories in Pakistan. The results obtained after testing have been compared with acceptance criteria (DEFSTAN 02-874 and standard reference material). Moreover results have been compared with contemporary steels used for marine applications. Results showed a reasonable agreement with results available in literature for other low alloy steels with respect to mechanical strength and weldability. Steel weldments qualified the weld joint strength tests and weldability tests. Toughness has been measured at various temperatures. Results revealed that the toughness of base metal is higher than heat affected zone (HAZ) and weld metal. In weldability tests, weld metal and HAZ were examined microscopically to investigate integrity of weld. No cracks have been observed in the weld which indicates complete diffusion in to the welding material. WH- 80 steel has exhibited comparatively high corrosion rate, reduction in tensile strength during SCC test and low Charpy energy values at -50 degree C. It is therefore concluded that the WH-80 steel is unsuitable for use in application at subzero (OC) temperatures and in highly corrosive environment. (author)

  2. Validation of a Short Form of an Indecision Test: The Vocational Assessment Test

    Science.gov (United States)

    Picard, France; Frenette, Éric; Guay, Frédéric; Labrosse, Julie

    2015-01-01

    The purpose of this research was to validate the scores of a short form of a new instrument, "l'Épreuve de décision vocationnelle, forme scolaire" (EDV-9S; vocational assessment test), which measures six indecision-related problems (lack of self-knowledge, lack of readiness, lack of method in decision making, lack of information,…

  3. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  4. Test Cost and Test Accuracy in Clinical Laboratories in Kampala, Uganda.

    Science.gov (United States)

    Amukele, Timothy K; Jones, Robert; Elbireer, Ali

    2018-04-25

    To assess the accuracy and costs of laboratory tests in Kampala, Uganda. A random selection of 78 laboratories tested external quality assurance samples at market rates. There were 40 moderate- to high-complexity and 38 low-complexity laboratories. Four percent (3/78) of these laboratories were accredited and 94% (73/78) were private. The 40 moderate- to high-complexity laboratories performed malaria blood smear, urine human chorionic gonadotropin (hCG), human immunodeficiency virus (HIV), syphilis, glucose, and three-panel tests: CBC, liver function tests, and kidney function tests. The 38 low-complexity laboratories performed malaria blood smear, urine hCG, and syphilis testing only. Hematology, HIV, syphilis, and malarial proficiency testing samples were prepared by accredited laboratories in Kampala. All other samples were provided by the Royal College of Pathologists of Australia. 77.1% of all results were accurate (met target values). It varied widely by laboratory (50%-100%), test identity (malaria blood smear, 96%; serum urea nitrogen, 38%), and test type (quantitative: 66% [31%-89%], qualitative: 91% [68%-97%]). Test prices varied by up to 3,600%, and there was no correlation between test cost and accuracy (r2 = 0.02). There were large differences in accuracy and price across laboratories in Kampala. Price was not associated with quality.

  5. Testing and assessment strategies, including alternative and new approaches

    DEFF Research Database (Denmark)

    Meyer, Otto A.

    2003-01-01

    The object of toxicological testing is to predict possible adverse effect in humans when exposed to chemicals whether used as industrial chemicals, pharmaceuticals or pesticides. Animal models are predominantly used in identifying potential hazards of chemicals. The use of laboratory animals raises...... ethical concern. However, irrespective of animal welfare it is an important aspect of the discipline of toxicology that the primary object is human health. The ideal testing and assessment strategy is simple to use all the available test methods and preferably more in laboratory animal species from which...... uses and of the absence of health problems involved with their use. Thus, the regulatory toxicology is a cocktail of science and pragmatism added a crucial concern for animal welfare. Test methods are most often used in a testing sequence as bricks in a testing strategy. The main key driving forces...

  6. Accuracy of young male drivers’ self-assessments of driving skill

    DEFF Research Database (Denmark)

    Martinussen, Laila Marianne; Møller, Mette; Prato, Carlo Giacomo

    2017-01-01

    Accurate self-assessment of skill is important because it creates an appropriate level of confidence and hence behaviour. Inaccurate self-assessment of driving ability has been linked to reckless driving and accidents. Inaccurate self-assessment of driving skills may be a contributing factor...... to the over-representation of young male drivers in accident statistics. Most previous research on self-assessment of driving skills did not compare self-reported skills to objectively measured driving skills, so the aims of this study were: (1) to test the accuracy of young male drivers’ self......-assessments of specific driving skills by comparing them with performance in a driving simulator; (2) to test whether self-assessment accuracy varied with driving skill, driving experience and sensation-seeking propensity. We found that young male drivers’ self-assessments were inconsistent with their driving performance...

  7. Meta-analytic approach to the accurate prediction of secreted virulence effectors in gram-negative bacteria

    Directory of Open Access Journals (Sweden)

    Sato Yoshiharu

    2011-11-01

    Full Text Available Abstract Background Many pathogens use a type III secretion system to translocate virulence proteins (called effectors in order to adapt to the host environment. To date, many prediction tools for effector identification have been developed. However, these tools are insufficiently accurate for producing a list of putative effectors that can be applied directly for labor-intensive experimental verification. This also suggests that important features of effectors have yet to be fully characterized. Results In this study, we have constructed an accurate approach to predicting secreted virulence effectors from Gram-negative bacteria. This consists of a support vector machine-based discriminant analysis followed by a simple criteria-based filtering. The accuracy was assessed by estimating the average number of true positives in the top-20 ranking in the genome-wide screening. In the validation, 10 sets of 20 training and 20 testing examples were randomly selected from 40 known effectors of Salmonella enterica serovar Typhimurium LT2. On average, the SVM portion of our system predicted 9.7 true positives from 20 testing examples in the top-20 of the prediction. Removal of the N-terminal instability, codon adaptation index and ProtParam indices decreased the score to 7.6, 8.9 and 7.9, respectively. These discrimination features suggested that the following characteristics of effectors had been uncovered: unstable N-terminus, non-optimal codon usage, hydrophilic, and less aliphathic. The secondary filtering process represented by coexpression analysis and domain distribution analysis further refined the average true positive counts to 12.3. We further confirmed that our system can correctly predict known effectors of P. syringae DC3000, strongly indicating its feasibility. Conclusions We have successfully developed an accurate prediction system for screening effectors on a genome-wide scale. We confirmed the accuracy of our system by external validation

  8. Open-book tests to complement assessment-programmes : Analysis of open and closed-book tests

    NARCIS (Netherlands)

    Heijne-Penninga, M.; Kuks, J. B. M.; Schonrock-Adema, J.; Snijders, T. A. B.; Cohen-Schotanus, J.

    Today's health sciences educational programmes have to deal with a growing and changing amount of knowledge. It is becoming increasingly important for students to be able to use and manage knowledge. We suggest incorporating open-book tests in assessment programmes to meet these changes. This view

  9. PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Martí-Climent, Josep M., E-mail: jmmartic@unav.es; Prieto, Elena; Elosúa, César; Rodríguez-Fraile, Macarena; Domínguez-Prado, Inés; Vigil, Carmen; García-Velloso, María J.; Arbizu, Javier; Peñuelas, Iván; Richter, José A. [Nuclear Medicine Department, Clínica Universidad de Navarra, 36, Pío XII Avenue, 31008 Pamplona (Spain)

    2014-09-15

    Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET

  10. Assessing smoking status in disadvantaged populations: is computer administered self report an accurate and acceptable measure?

    Directory of Open Access Journals (Sweden)

    Bryant Jamie

    2011-11-01

    Full Text Available Abstract Background Self report of smoking status is potentially unreliable in certain situations and in high-risk populations. This study aimed to determine the accuracy and acceptability of computer administered self-report of smoking status among a low socioeconomic (SES population. Methods Clients attending a community service organisation for welfare support were invited to complete a cross-sectional touch screen computer health survey. Following survey completion, participants were invited to provide a breath sample to measure exposure to tobacco smoke in expired air. Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Results Three hundred and eighty three participants completed the health survey, and 330 (86% provided a breath sample. Of participants included in the validation analysis, 59% reported being a daily or occasional smoker. Sensitivity was 94.4% and specificity 92.8%. The positive and negative predictive values were 94.9% and 92.0% respectively. The majority of participants reported that the touch screen survey was both enjoyable (79% and easy (88% to complete. Conclusions Computer administered self report is both acceptable and accurate as a method of assessing smoking status among low SES smokers in a community setting. Routine collection of health information using touch-screen computer has the potential to identify smokers and increase provision of support and referral in the community setting.

  11. DHS small-scale safety and thermal testing of improvised explosives-comparison of testing performance

    International Nuclear Information System (INIS)

    Reynolds, J G; Hsu, P C; Sandstrom, M M; Brown, G W; Warner, K F; Phillips, J J; Shelley, T J; Reyes, J A

    2014-01-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or homemade explosives (HMEs) to SSST testing, 16 HME materials were compared to three standard military explosives in a proficiency-type round robin study among five laboratories-two DoD and three DOE-sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials-powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. More than 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for developing safe handling and storage practices. This paper presents a generalized comparison of the results among the testing participants, comparison of friction results from BAM (German Bundesanstalt für Materi-alprüfung) and ABL (Allegany Ballistics Laboratory) designed testing equipment, and an overview of the statistical results from the RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) standard tested throughout the proficiency test.

  12. New Rock Abrasivity Test Method for Tool Life Assessments on Hard Rock Tunnel Boring: The Rolling Indentation Abrasion Test (RIAT)

    Science.gov (United States)

    Macias, F. J.; Dahl, F.; Bruland, A.

    2016-05-01

    The tunnel boring machine (TBM) method has become widely used and is currently an important presence within the tunnelling industry. Large investments and high geological risk are involved using TBMs, and disc cutter consumption has a great influence on performance and cost, especially in hard rock conditions. Furthermore, reliable cutter life assessments facilitate the control of risk as well as avoiding delays and budget overruns. Since abrasive wear is the most common process affecting cutter consumption, good laboratory tests for rock abrasivity assessments are needed. A new abrasivity test method by rolling disc named Rolling Indentation Abrasion Test (RIAT) has been developed. The goal of the new test design and procedure is to reproduce wear behaviour on hard rock tunnel boring in a more realistic way than the traditionally used methods. Wear by rolling contact on intact rock samples is introduced and several rock types, covering a wide rock abrasiveness range, have been tested by RIAT. The RIAT procedure indicates a great ability of the testing method to assess abrasive wear on rolling discs. In addition and to evaluate the newly developed RIAT test method, a comprehensive laboratory testing programme including the most commonly used abrasivity test methods and the mineral composition were carried out. Relationships between the achieved results from conventional testing and RIAT results have been analysed.

  13. Sitting and standing blood pressure measurements are not accurate for the diagnosis of orthostatic hypotension.

    LENUS (Irish Health Repository)

    Cooke, J

    2012-01-31

    INTRODUCTION: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH. DESIGN: Retrospective test of diagnostic accuracy. METHODS: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard. Both tests happened within 5 min of each other and patients underwent no intervention between tests. RESULTS: From a total of 1452 consecutive HUTs, we identified 730 with pre-test measures of sitting and standing BP. The mean age of this group was 70.57 years (SD = 15.1), 62% were female. The sensitivity of sit-stand testing was calculated as 15.5%, specificity as 89.9%, positive predictive value as 61.7%, negative predictive value as 50.2% and the likelihood ratio as 1.6. The area under the Receiver Operator Curve was 0.564. CONCLUSION: We have demonstrated that sit-stand testing for OH has very low diagnostic accuracy. We recommend that the more time-consuming reference standard method of diagnosis be used if the condition is suspected.

  14. Accurate relative location estimates for the North Korean nuclear tests using empirical slowness corrections

    Science.gov (United States)

    Gibbons, S. J.; Pabian, F.; Näsholm, S. P.; Kværna, T.; Mykkeltveit, S.

    2017-01-01

    Declared North Korean nuclear tests in 2006, 2009, 2013 and 2016 were observed seismically at regional and teleseismic distances. Waveform similarity allows the events to be located relatively with far greater accuracy than the absolute locations can be determined from seismic data alone. There is now significant redundancy in the data given the large number of regional and teleseismic stations that have recorded multiple events, and relative location estimates can be confirmed independently by performing calculations on many mutually exclusive sets of measurements. Using a 1-D global velocity model, the distances between the events estimated using teleseismic P phases are found to be approximately 25 per cent shorter than the distances between events estimated using regional Pn phases. The 2009, 2013 and 2016 events all take place within 1 km of each other and the discrepancy between the regional and teleseismic relative location estimates is no more than about 150 m. The discrepancy is much more significant when estimating the location of the more distant 2006 event relative to the later explosions with regional and teleseismic estimates varying by many hundreds of metres. The relative location of the 2006 event is challenging given the smaller number of observing stations, the lower signal-to-noise ratio and significant waveform dissimilarity at some regional stations. The 2006 event is however highly significant in constraining the absolute locations in the terrain at the Punggye-ri test-site in relation to observed surface infrastructure. For each seismic arrival used to estimate the relative locations, we define a slowness scaling factor which multiplies the gradient of seismic traveltime versus distance, evaluated at the source, relative to the applied 1-D velocity model. A procedure for estimating correction terms which reduce the double-difference time residual vector norms is presented together with a discussion of the associated uncertainty. The modified

  15. Are rapid diagnostic tests more accurate in diagnosis of plasmodium falciparum malaria compared to microscopy at rural health centres?

    Directory of Open Access Journals (Sweden)

    Magnussen Pascal

    2010-12-01

    Full Text Available Abstract Background Prompt, accurate diagnosis and treatment with artemisinin combination therapy remains vital to current malaria control. Blood film microscopy the current standard test for diagnosis of malaria has several limitations that necessitate field evaluation of alternative diagnostic methods especially in low income countries of sub-Saharan Africa where malaria is endemic. Methods The accuracy of axillary temperature, health centre (HC microscopy, expert microscopy and a HRP2-based rapid diagnostic test (Paracheck was compared in predicting malaria infection using polymerase chain reaction (PCR as the gold standard. Three hundred patients with a clinical suspicion of malaria based on fever and or history of fever from a low and high transmission setting in Uganda were consecutively enrolled and provided blood samples for all tests. Accuracy of each test was calculated overall with 95% confidence interval and then adjusted for age-groups and level of transmission intensity using a stratified analysis. The endpoints were: sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV. This study is registered with Clinicaltrials.gov, NCT00565071. Results Of the 300 patients, 88(29.3% had fever, 56(18.7% were positive by HC microscopy, 47(15.7% by expert microscopy, 110(36.7% by Paracheck and 89(29.7% by PCR. The overall sensitivity >90% was only shown by Paracheck 91.0% [95%CI: 83.1-96.0]. The sensitivity of expert microscopy was 46%, similar to HC microscopy. The superior sensitivity of Paracheck compared to microscopy was maintained when data was stratified for transmission intensity and age. The overall specificity rates were: Paracheck 86.3% [95%CI: 80.9-90.6], HC microscopy 93.4% [95%CI: 89.1-96.3] and expert microscopy 97.2% [95%CI: 93.9-98.9]. The NPV >90% was shown by Paracheck 95.8% [95%CI: 91.9-98.2]. The overall PPV was Conclusion The HRP2-based RDT has shown superior sensitivity compared to

  16. Usefulness of the jump-and-reach test in assessment of vertical jump performance.

    Science.gov (United States)

    Menzel, Hans-Joachim; Chagas, Mauro H; Szmuchrowski, Leszek A; Araujo, Silvia R; Campos, Carlos E; Giannetti, Marcus R

    2010-02-01

    The objective was to estimate the reliability and criterion-related validity of the Jump-and-Reach Test for the assessment of squat, countermovement, and drop jump performance of 32 male Brazilian professional volleyball players. Performance of squat, countermovement, and drop jumps with different dropping heights was assessed on the Jump-and-Reach Test and the measurement of flight time, then compared across different jump trials. The very high reliability coefficients of both assessment methods and the lower correlation coefficients between scores on the assessments indicate a very high consistency of each method but only moderate covariation, which means that they measure partly different items. As a consequence, the Jump-and-Reach Test has good ecological validity in situations when reaching height during the flight phase is critical for performance (e.g., basketball and volleyball) but only limited accuracy for the assessment of vertical impulse production with different jump techniques and conditions.

  17. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Guogen Shan

    2015-01-01

    Full Text Available Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003. However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  18. The application of miniature disc testing for the assessment of creep damage in CrMoV rotor steel

    Energy Technology Data Exchange (ETDEWEB)

    Parker, J D; Stratford, G C [University of Wales, Swansea (United Kingdom); Shaw, N; Spink, G [National Power plc (United Kingdom); Metcalfe, H [Siemens Power Generation (United Kingdom)

    1999-12-31

    A range of critical experiments has been performed studying the creep and fracture behaviour of a typical CrMoV rotor steel. Initially, uniaxial tests were carried out to provide material with a predetermined level of creep damage. Then, miniature disc tests were undertaken under accelerated conditions in a similar manner to procedures used for post-exposure uniaxial testing of service components. Data analysis demonstrates that the miniature tests accurately reflect the damage present so that this approach can be used to support run/repair/replace decisions. (orig.) 8 refs.

  19. The application of miniature disc testing for the assessment of creep damage in CrMoV rotor steel

    Energy Technology Data Exchange (ETDEWEB)

    Parker, J.D.; Stratford, G.C. [University of Wales, Swansea (United Kingdom); Shaw, N.; Spink, G. [National Power plc (United Kingdom); Metcalfe, H. [Siemens Power Generation (United Kingdom)

    1998-12-31

    A range of critical experiments has been performed studying the creep and fracture behaviour of a typical CrMoV rotor steel. Initially, uniaxial tests were carried out to provide material with a predetermined level of creep damage. Then, miniature disc tests were undertaken under accelerated conditions in a similar manner to procedures used for post-exposure uniaxial testing of service components. Data analysis demonstrates that the miniature tests accurately reflect the damage present so that this approach can be used to support run/repair/replace decisions. (orig.) 8 refs.

  20. KFM: a homemade yet accurate and dependable fallout meter

    International Nuclear Information System (INIS)

    Kearny, C.H.; Barnes, P.R.; Chester, C.V.; Cortner, M.W.

    1978-01-01

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of +-25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The step-by-step illustrated instructions for making and using a KFM are presented. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM

  1. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    Science.gov (United States)

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  2. A street intercept survey to assess HIV-testing attitudes and behaviors.

    Science.gov (United States)

    Rotheram-Borus, M J; Mann, T; Newman, P A; Grusky, O; Frerichs, R R; Wight, R G; Kuklinski, M

    2001-06-01

    Nationally, it has been estimated that 44% of adults in the United States have been tested for HIV, with substantial individual and community-level variations in HIV-testing attitudes and behaviors. HIV-testing behaviors and intentions and attitudes toward HIV testing, particularly toward home tests, were assessed among 385 adults recruited in a street intercept survey from a gay-identified agency, a substance-abuse treatment program, and inner-city community venues (a shopping mall and community center). Across these Los Angeles sites, the proportion of persons reported being tested for HIV in their lifetime (77%) was higher than the national estimate. Gay-identified agency (88%) and substance-abuse treatment program participants (99%) were more likely to have been tested than were the community participants (67%). Participants from a gay-identified agency were more likely to have had an anonymous test (51%) than were those from a substance-abuse treatment program (25%) or community sites (24%). Attitudes toward HIV testing, including mail-in home-test kits and instant home tests, were very positive. Most participants were willing to pay about $20 for a home-test kit. Participants from the community sites (82%) and the substance-abuse treatment program participants (87%) endorsed notification of HIV status to health departments and sexual partners more than did participants from the gay identified agency (48%). The street intercept survey appears to be a quick and feasible method to assess HIV testing in urban areas.

  3. A Serious Flaw in the Collegiate Learning Assessment [CLA] Test

    Directory of Open Access Journals (Sweden)

    Kevin Possin

    2013-09-01

    Full Text Available The Collegiate Learning Assessment Test (CLA has become popular and highly recommended, praised for its reliability and validity. I argue that while the CLA may be a commendable test for measuring critical-thinking, problem-solving, and logical-reasoning skills, those who are scoring students’ answers to the test’s questions are rendering the CLA invalid.

  4. The Caledonian face test: A new test of face discrimination.

    Science.gov (United States)

    Logan, Andrew J; Wilkinson, Frances; Wilson, Hugh R; Gordon, Gael E; Loffler, Gunter

    2016-02-01

    This study aimed to develop a clinical test of face perception which is applicable to a wide range of patients and can capture normal variability. The Caledonian face test utilises synthetic faces which combine simplicity with sufficient realism to permit individual identification. Face discrimination thresholds (i.e. minimum difference between faces required for accurate discrimination) were determined in an "odd-one-out" task. The difference between faces was controlled by an adaptive QUEST procedure. A broad range of face discrimination sensitivity was determined from a group (N=52) of young adults (mean 5.75%; SD 1.18; range 3.33-8.84%). The test is fast (3-4 min), repeatable (test-re-test r(2)=0.795) and demonstrates a significant inversion effect. The potential to identify impairments of face discrimination was evaluated by testing LM who reported a lifelong difficulty with face perception. While LM's impairment for two established face tests was close to the criterion for significance (Z-scores of -2.20 and -2.27) for the Caledonian face test, her Z-score was -7.26, implying a more than threefold higher sensitivity. The new face test provides a quantifiable and repeatable assessment of face discrimination ability. The enhanced sensitivity suggests that the Caledonian face test may be capable of detecting more subtle impairments of face perception than available tests. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Accurate source location from waves scattered by surface topography: Applications to the Nevada and North Korean test sites

    Science.gov (United States)

    Shen, Y.; Wang, N.; Bao, X.; Flinders, A. F.

    2016-12-01

    Scattered waves generated near the source contains energy converted from the near-field waves to the far-field propagating waves, which can be used to achieve location accuracy beyond the diffraction limit. In this work, we apply a novel full-wave location method that combines a grid-search algorithm with the 3D Green's tensor database to locate the Non-Proliferation Experiment (NPE) at the Nevada test site and the North Korean nuclear tests. We use the first arrivals (Pn/Pg) and their immediate codas, which are likely dominated by waves scattered at the surface topography near the source, to determine the source location. We investigate seismograms in the frequency of [1.0 2.0] Hz to reduce noises in the data and highlight topography scattered waves. High resolution topographic models constructed from 10 and 90 m grids are used for Nevada and North Korea, respectively. The reference velocity model is based on CRUST 1.0. We use the collocated-grid finite difference method on curvilinear grids to calculate the strain Green's tensor and obtain synthetic waveforms using source-receiver reciprocity. The `best' solution is found based on the least-square misfit between the observed and synthetic waveforms. To suppress random noises, an optimal weighting method for three-component seismograms is applied in misfit calculation. Our results show that the scattered waves are crucial in improving resolution and allow us to obtain accurate solutions with a small number of stations. Since the scattered waves depends on topography, which is known at the wavelengths of regional seismic waves, our approach yields absolute, instead of relative, source locations. We compare our solutions with those of USGS and other studies. Moreover, we use differential waveforms to locate pairs of the North Korea tests from years 2006, 2009, 2013 and 2016 to further reduce the effects of unmodeled heterogeneities and errors in the reference velocity model.

  6. 3D-based visual physical activity assessment of children

    Directory of Open Access Journals (Sweden)

    Maile S.

    2015-09-01

    Full Text Available In the last decades, an alarming rise in prevalence of childhood overweight and obesity has been observed which is partly attributed to a lack in physical activity and has started to become a public health concern. Therefore, the necessity for accurate physical activity assessment has become more and more apparent. Physical activity can be assessed objectively using accelerometers or combined devices. The application of such devices is sometimes complex and wearing the device may influence the behaviour of the test person. Therefore, assessment without any worn device would be an advantage.

  7. [Normative values of kinetic tests in VNG assessment].

    Science.gov (United States)

    Zamysłowska-Szmytke, Ewa; Sliwińska-Kowalska, Mariola

    2011-01-01

    Balance assessment plays an important role in occupational medicine. The diagnosis of patients with balance disturbances is based on a number of laboratory tests, including rotational chair tests, one of the most important. The normative value of kinetic tests greatly depends on movement parameters and laboratory equipment, which vary between diagnostic centers. The aim of the presented paper was to establish normatives for our laboratory and testing methodology in a group of healthy persons. The balance examination included 45 healthy persons (21 women and 24 men) aged 20-63 years (mean 38.5 +/- 14.9). The study population underwent very thorough neuro-otological examination, static posturography and VNG tests. The caloric test result was a crucial criterion for inclusion to the group of healthy persons. Rotational tests included: one "burst" test analyzing vestibulo-ocular reflex (VOR) with and without optokinetic stimulation visual vestibular optokinetic reflex (VVOR) and cervico-ocular reflex (COR); three impulse tests and sinusoidal harmonic rotation tests of 0.04, 0.08, 0.1, 0.16, 0.32, and 0.64 Hz. The mean values were: VVOR, 0.9 +/- 0.1; VOR, 0.5 +/- 0.1; and COR, 0.2 +/- 0.1. The mean value of rotational and post-rotational nystagmus induced by sudden chair stop (impulse stimulus) was 9 +/- 7 s, the gain values were 0.4 for sinusoidal tests, in the stimulation range of 0.1-0.32 and 0.5 for 0.64 Hz stimulation. There was no significant linear relationship between age and test parameters except for the test using sinusoidal-decreasing stimulation. These normative values form the base for a closer incorporation of rotational tests in occupational medicine procedures.

  8. In-situ measurements of material thermal parameters for accurate LED lamp thermal modelling

    NARCIS (Netherlands)

    Vellvehi, M.; Perpina, X.; Jorda, X.; Werkhoven, R.J.; Kunen, J.M.G.; Jakovenko, J.; Bancken, P.; Bolt, P.J.

    2013-01-01

    This work deals with the extraction of key thermal parameters for accurate thermal modelling of LED lamps: air exchange coefficient around the lamp, emissivity and thermal conductivity of all lamp parts. As a case study, an 8W retrofit lamp is presented. To assess simulation results, temperature is

  9. Food habits and nutritional status assessment of adolescent soccer players. A necessary and accurate approach.

    Science.gov (United States)

    Iglesias-Gutiérrez, Eduardo; García-Rovés, Pablo M; Rodríguez, Carmen; Braga, Socorro; García-Zapico, Pedro; Patterson, Angeles M

    2005-02-01

    The aim of this study was to assess the food habits and nutritional status of high level adolescent soccer players (N = 33; ages 14-16 yrs) living in their home environment. Body composition (height, mass, skinfolds), biochemical and hematological parameters, performance in soccer-specific tests (sprinting, jumping, intermittent endurance), and dietary intake (weighed food intake method) and related behaviors (nutrient supplement use, daily activity profile) were assessed. Daily energy expenditure and energy intake were 12.5 MJ and 12.6 MJ, respectively. Protein (16% of energy intake; 1.9 g/kg of body mass), lipid (38%), and cholesterol (385 mg) intake were above recommendations, while carbohydrates (45%) were below. The food intake of these adolescents was based on cereals and derivates; meat, fish, and eggs; milk and dairy products; biscuits and confectionery; and oil, butter and margarine, which provided 78% of total energy intake, 85% of proteins, 64% of carbohydrates, 90% of lipids, and 47% of fiber. Although diet provided sufficient iron, 48% of individuals showed iron deficiency without anemia. Based on these results, a well designed nutrition intervention would be advisable for optimizing performance, and especially for promoting healthy eating habits in adolescent soccer players.

  10. Orthopaedic nurses' knowledge and interrater reliability of neurovascular assessments with 2-point discrimination test.

    Science.gov (United States)

    Turney, Jennifer; Raley Noble, Deana; Kim, Son Chae

    2013-01-01

    : This study was conducted to evaluate the effects of education on knowledge and interrater reliability of neurovascular assessments with 2-point discrimination (2-PD) test among pediatric orthopaedic nurses. : A pre- and posttest study was done among 60 nurses attending 2-hour educational sessions. Neurovascular assessments with 2-PD test were performed on 64 casted pediatric patients by the nurses and 5 nurse experts before and after the educational sessions. : The mean neurovascular assessment knowledge score was improved at posteducation compared with the preeducation (p < .001). The 2-PD test interrater reliability also improved from Cohen's kappa value of 0.24-0.48 at posteducation. : The 2-hour educational session may be effective in improving nurses' knowledge and the interrater reliability of neurovascular assessment with 2-PD test.

  11. DisoMCS: Accurately Predicting Protein Intrinsically Disordered Regions Using a Multi-Class Conservative Score Approach.

    Directory of Open Access Journals (Sweden)

    Zhiheng Wang

    Full Text Available The precise prediction of protein intrinsically disordered regions, which play a crucial role in biological procedures, is a necessary prerequisite to further the understanding of the principles and mechanisms of protein function. Here, we propose a novel predictor, DisoMCS, which is a more accurate predictor of protein intrinsically disordered regions. The DisoMCS bases on an original multi-class conservative score (MCS obtained by sequence-order/disorder alignment. Initially, near-disorder regions are defined on fragments located at both the terminus of an ordered region connecting a disordered region. Then the multi-class conservative score is generated by sequence alignment against a known structure database and represented as order, near-disorder and disorder conservative scores. The MCS of each amino acid has three elements: order, near-disorder and disorder profiles. Finally, the MCS is exploited as features to identify disordered regions in sequences. DisoMCS utilizes a non-redundant data set as the training set, MCS and predicted secondary structure as features, and a conditional random field as the classification algorithm. In predicted near-disorder regions a residue is determined as an order or a disorder according to the optimized decision threshold. DisoMCS was evaluated by cross-validation, large-scale prediction, independent tests and CASP (Critical Assessment of Techniques for Protein Structure Prediction tests. All results confirmed that DisoMCS was very competitive in terms of accuracy of prediction when compared with well-established publicly available disordered region predictors. It also indicated our approach was more accurate when a query has higher homologous with the knowledge database.The DisoMCS is available at http://cal.tongji.edu.cn/disorder/.

  12. Environmental assessment report: Nuclear Test Technology Complex

    International Nuclear Information System (INIS)

    Tonnessen, K.; Tewes, H.A.

    1982-08-01

    The US Department of Energy (USDOE) is planning to construct and operate a structure, designated the Nuclear Test Technology Complex (NTTC), on a site located west of and adjacent to the Lawrence Livermore National Laboratory. The NTTC is designed to house 350 nuclear test program personnel, and will accommodate the needs of the entire staff of the continuing Nuclear Test Program (NTP). The project has three phases: land acquisition, facility construction and facility operation. The purpose of this environmental assessment report is to describe the activities associated with the three phases of the NTTC project and to evaluate potential environmental disruptions. The project site is located in a rural area of southeastern Alameda County, California, where the primary land use is agriculture; however, the County has zoned the area for industrial development. The environmental impacts of the project include surface disturbance, high noise levels, possible increases in site erosion, and decreased air quality. These impacts will occur primarily during the construction phase of the NTTC project and can be mitigated in part by measures proposed in this report

  13. Testing of an accident consequence assessment model using field data

    International Nuclear Information System (INIS)

    Homma, Toshimitsu; Matsubara, Takeshi; Tomita, Kenichi

    2007-01-01

    This paper presents the results obtained from the application of an accident consequence assessment model, OSCAAR to the Iput dose reconstruction scenario of BIOMASS and also to the Chernobyl 131 I fallout scenario of EMRAS, both organized by International Atomic Energy Agency. The Iput Scenario deals with 137 Cs contamination of the catchment basin and agricultural area in the Bryansk Region of Russia, which was heavily contaminated after the Chernobyl accident. This exercise was used to test the chronic exposure pathway models in OSCAAR with actual measurements and to identify the most important sources of uncertainty with respect to each part of the assessment. The OSCAAR chronic exposure pathway models had some limitations but the refined model, COLINA almost successfully reconstructed the whole 10-year time course of 137 Cs activity concentrations in most requested types of agricultural products and natural foodstuffs. The Plavsk scenario provides a good opportunity to test not only the food chain transfer model of 131 I but also the method of assessing 131 I thyroid burden. OSCAAR showed in general good capabilities for assessing the important 131 I exposure pathways. (author)

  14. MDCT assessment of resectability in hilar cholangiocarcinoma.

    Science.gov (United States)

    Ni, Qihong; Wang, Haolu; Zhang, Yunhe; Qian, Lijun; Chi, Jiachang; Liang, Xiaowen; Chen, Tao; Wang, Jian

    2017-03-01

    The purpose of this study is to investigate the value of multidetector computed tomography (MDCT) assessment of resectability in hilar cholangiocarcinoma, and to identify the factors associated with unresectability and accurate evaluation of resectability. From January 2007 to June 2015, a total of 77 consecutive patients were included. All patients had preoperative MDCT (with MPR and MinIP) and surgical treatment, and were pathologically proven with hilar cholangiocarcinoma. The MDCT images were reviewed retrospectively by two senior radiologists and one hepatobiliary surgeon. The surgical findings and pathologic results were considered to be the gold standard. The Chi square test was used to identify factors associated with unresectability and accurate evaluation of resectability. The sensitivity, specificity, and overall accuracy of MDCT assessment were 83.3 %, 75.9 %, and 80.5 %, respectively. The main causes of inaccuracy were incorrect evaluation of N2 lymph node metastasis (4/15) and distant metastasis (4/15). Bismuth type IV tumor, main or bilateral hepatic artery involvement, and main or bilateral portal vein involvement were highly associated with unresectability (P hilar cholangiocarcinoma. Bismuth type IV tumor and main or bilateral vascular involvement highly suggest the unresectability of hilar cholangiocarcinoma. Patients without biliary drainage have a more accurate MDCT evaluation of resectability. We suggest MDCT should be performed before biliary drainage to achieve an accurate evaluation of resectability in hilar cholangiocarcinoma.

  15. Negotiating the use of formative assessment for learning in an era of accountability testing

    Science.gov (United States)

    Yin, Xinying

    The purpose of this collaborative action research was to understand how science educators can negotiate the tension between integrating formative assessment (FA) for students' learning and meeting the need for standardized summative assessment (testing) from a critical perspective. Using formative assessment in the era of accountability testing was a process in which the science educators identified the ways that the standardized testing system constrained the teacher's use of FA to improve students' learning, sought solutions to overcome the obstacles and came to understand how FA can be utilized to neutralize the power relationship between the institutional requirement and classroom teaching and learning. The challenge of doing FA under the pressure of standardized testing mainly lie in two dimensions: one was the demand of teaching all the desired standard-based content to all students in a limited amount of time and the sufficient time and flexibility required by doing FA to improve students' understanding, the other was the different levels of knowledge and forms of knowledge representation on FA and tests. The negotiation of doing FA for teaching standards and preparing students for tests entailed six aspects for the collaborative team, including clarifying teaching objectives, reconstructing instructional activities, negotiating with time constraints, designing effective FA activities, attending to students' needs in doing FA, and modifying end-of-unit tests to better assess the learning goals. As the teacher's instructional goals evolved to be more focused on conceptual understanding of standards and more thorough understanding for less activities, she perceived doing FA for learning and preparing students for standardized tests as more congruent. By integrating both divergent and convergent FA into instruction as well as modifying tests to be more aligned with standards, students' learning were enhanced and they were also being prepared for tests. This

  16. Recent development in low-constraint fracture toughness testing for structural integrity assessment of pipelines

    Science.gov (United States)

    Kang, Jidong; Gianetto, James A.; Tyson, William R.

    2018-03-01

    Fracture toughness measurement is an integral part of structural integrity assessment of pipelines. Traditionally, a single-edge-notched bend (SE(B)) specimen with a deep crack is recommended in many existing pipeline structural integrity assessment procedures. Such a test provides high constraint and therefore conservative fracture toughness results. However, for girth welds in service, defects are usually subjected to primarily tensile loading where the constraint is usually much lower than in the three-point bend case. Moreover, there is increasing use of strain-based design of pipelines that allows applied strains above yield. Low-constraint toughness tests represent more realistic loading conditions for girth weld defects, and the corresponding increased toughness can minimize unnecessary conservatism in assessments. In this review, we present recent developments in low-constraint fracture toughness testing, specifically using single-edgenotched tension specimens, SENT or SE(T). We focus our review on the test procedure development and automation, round-robin test results and some common concerns such as the effect of crack tip, crack size monitoring techniques, and testing at low temperatures. Examples are also given of the integration of fracture toughness data from SE(T) tests into structural integrity assessment.

  17. Podiatry Ankle Duplex Scan: Readily Learned and Accurate in Diabetes.

    Science.gov (United States)

    Normahani, Pasha; Powezka, Katarzyna; Aslam, Mohammed; Standfield, Nigel J; Jaffer, Usman

    2018-03-01

    We aimed to train podiatrists to perform a focused duplex ultrasound scan (DUS) of the tibial vessels at the ankle in diabetic patients; podiatry ankle (PodAnk) duplex scan. Thirteen podiatrists underwent an intensive 3-hour long simulation training session. Participants were then assessed performing bilateral PodAnk duplex scans of 3 diabetic patients with peripheral arterial disease. Participants were assessed using the duplex ultrasound objective structured assessment of technical skills (DUOSATS) tool and an "Imaging Score". A total of 156 vessel assessments were performed. All patients had abnormal waveforms with a loss of triphasic flow. Loss of triphasic flow was accurately detected in 145 (92.9%) vessels; the correct waveform was identified in 139 (89.1%) cases. Participants achieved excellent DUOSATS scores (median 24 [interquartile range: 23-25], max attainable score of 26) as well as "Imaging Scores" (8 [8-8], max attainable score of 8) indicating proficiency in technical skills. The mean time taken for each bilateral ankle assessment was 20.4 minutes (standard deviation ±6.7). We have demonstrated that a focused DUS for the purpose of vascular assessment of the diabetic foot is readily learned using intensive simulation training.

  18. The International Test Commission Guidelines on the Security of Tests, Examinations, and Other Assessments

    Science.gov (United States)

    International Journal of Testing, 2016

    2016-01-01

    The amount and severity of security threats have increased considerably over the past two decades, calling into question the validity of assessments administered around the world. These threats have increased for a number of reasons, including the popular use of computerized and online technologies for test administration and the use of almost…

  19. An assessment of the usefulness of a rapid immuno-chromatographic test, "Determine™ malaria pf" in evaluation of intervention measures in forest villages of central India

    Directory of Open Access Journals (Sweden)

    Shukla Manmohan

    2001-08-01

    Full Text Available Abstract Background Plasmodium falciparum malaria, is a major health problem in forested tribal belt of central India. Rapid and accurate methods are needed for the diagnosis of P. falciparum. We performed a blinded evaluation of the recently introduced Determine™ malaria pf test (Abbott, Laboratories, Japan compared with microscopy and splenomegaly in children in epidemic prone areas of district Mandla to assess the impact of intervention measures. Methods Children aged 2–10 yrs with and without fever were examined for spleen enlargement by medical specialist by establishing a mobile field clinic. From these children thick blood smears were prepared from finger prick and read by a technician. Simultaneously, rapid tests were performed by a field lab attendant. The figures for specificity, sensitivity and predictive values were calculated using microscopy as gold standard. Results In all 349 children were examined. The sensitivity and specificity for Determine rapid diagnostic test were 91 and 80% respectively. The positive predictive values (PPV, negative predictive values (NPV and accuracy of the test were respectively 79, 91 and 85%. On the contrary, the sensitivity and specificity of spleen in detecting malaria infection were 57 and 74 % respectively with PPV of 73%, NPV 59 % and an accuracy of 65%. Conclusions Determine™ malaria rapid diagnostic test is easier and quicker to perform and has other advantages over microscopy in not requiring prior training of personnel or quality control. Thus, highlighting the usefulness of a rapid antigen test in assessing prevailing malaria situation in remote areas.

  20. Distinguishing highly confident accurate and inaccurate memory: insights about relevant and irrelevant influences on memory confidence.

    Science.gov (United States)

    Chua, Elizabeth F; Hannula, Deborah E; Ranganath, Charan

    2012-01-01

    It is generally believed that accuracy and confidence in one's memory are related, but there are many instances when they diverge. Accordingly it is important to disentangle the factors that contribute to memory accuracy and confidence, especially those factors that contribute to confidence, but not accuracy. We used eye movements to separately measure fluent cue processing, the target recognition experience, and relative evidence assessment on recognition confidence and accuracy. Eye movements were monitored during a face-scene associative recognition task, in which participants first saw a scene cue, followed by a forced-choice recognition test for the associated face, with confidence ratings. Eye movement indices of the target recognition experience were largely indicative of accuracy, and showed a relationship to confidence for accurate decisions. In contrast, eye movements during the scene cue raised the possibility that more fluent cue processing was related to higher confidence for both accurate and inaccurate recognition decisions. In a second experiment we manipulated cue familiarity, and therefore cue fluency. Participants showed higher confidence for cue-target associations for when the cue was more familiar, especially for incorrect responses. These results suggest that over-reliance on cue familiarity and under-reliance on the target recognition experience may lead to erroneous confidence.

  1. An investigation of highly accurate and precise robotic hole measurements using non-contact devices

    Directory of Open Access Journals (Sweden)

    Usman Zahid

    2016-01-01

    Full Text Available Industrial robots arms are widely used in manufacturing industry because of their support for automation. However, in metrology, robots have had limited application due to their insufficient accuracy. Even using error compensation and calibration methods, robots are not effective for micrometre (μm level metrology. Non-contact measurement devices can potentially enable the use of robots for highly accurate metrology. However, the use of such devices on robots has not been investigated. The research work reported in this paper explores the use of different non-contact measurement devices on an industrial robot. The aim is to experimentally investigate the effects of robot movements on the accuracy and precision of measurements. The focus has been on assessing the ability to accurately measure various geometric and surface parameters of holes despite the inherent inaccuracies of industrial robot. This involves the measurement of diameter, roundness and surface roughness. The study also includes scanning of holes for measuring internal features such as start and end point of a taper. Two different non-contact measurement devices based on different technologies are investigated. Furthermore, effects of eccentricity, vibrations and thermal variations are also assessed. The research contributes towards the use of robots for highly accurate and precise robotic metrology.

  2. Accurate and inaccurate HIV transmission beliefs, stigmatizing and HIV protection motivation in northern Thailand

    NARCIS (Netherlands)

    Boer, Hendrik; Emons, P.A.A.; Emons, P.A.A.

    2004-01-01

    We assessed the relation between accurate beliefs about HIV transmission and inaccurate beliefs about HIV transmission and emotional reactions to people with AIDS (PWA) and AIDS risk groups, stigmatizing attitudes and motivation to protect from HIV. In Chiang Rai, northern Thailand, 219 respondents

  3. Ecological-economical approach to assessment of environment state at the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Chugunova, N.S.; Balykbaeva, S.Y.

    2002-01-01

    The paper presents methods used for ecological-economical assessment of the environment condition at the former Semipalatinsk Test Site. It also presents methodology of calculating ecological and economical parameters for different options. Besides, the paper provides data describing assessment of ecological and economical damage caused by defense establishment activities at the Semipalatinsk Test Site. (author)

  4. ASTRAL, DRAGON and SEDAN scores predict stroke outcome more accurately than physicians.

    Science.gov (United States)

    Ntaios, G; Gioulekas, F; Papavasileiou, V; Strbian, D; Michel, P

    2016-11-01

    ASTRAL, SEDAN and DRAGON scores are three well-validated scores for stroke outcome prediction. Whether these scores predict stroke outcome more accurately compared with physicians interested in stroke was investigated. Physicians interested in stroke were invited to an online anonymous survey to provide outcome estimates in randomly allocated structured scenarios of recent real-life stroke patients. Their estimates were compared to scores' predictions in the same scenarios. An estimate was considered accurate if it was within 95% confidence intervals of actual outcome. In all, 244 participants from 32 different countries responded assessing 720 real scenarios and 2636 outcomes. The majority of physicians' estimates were inaccurate (1422/2636, 53.9%). 400 (56.8%) of physicians' estimates about the percentage probability of 3-month modified Rankin score (mRS) > 2 were accurate compared with 609 (86.5%) of ASTRAL score estimates (P DRAGON score estimates (P DRAGON score estimates (P DRAGON and SEDAN scores predict outcome of acute ischaemic stroke patients with higher accuracy compared to physicians interested in stroke. © 2016 EAN.

  5. Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.

    Science.gov (United States)

    Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C

    2016-06-01

    The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.

  6. Evaluating the relationship between plasma and skin carotenoids and reported dietary intake in elementary school children to assess fruit and vegetable intake

    Science.gov (United States)

    Accurate assessment of dietary intake of children can be challenging due to the limited reliability of current dietary assessment methods in children. While plasma carotenoid concentrations has been used to assess fruit and vegetable intake, this testing is rarely conducted in school settings in chi...

  7. Test Bed for Safety Assessment of New e-Navigation Systems

    Directory of Open Access Journals (Sweden)

    Axel Hahn

    2014-12-01

    Full Text Available New e-navigation strains require new technologies, new infrastructures and new organizational structures on bridge, on shore as well as in the cloud. Suitable engineering and safety/risk assessment methods facilitate these efforts. Understanding maritime transportation as a sociotechnical system allows the application of system-engineering methods. Formal, simulation based and in situ verification and validation of e-navigation technologies are important methods to obtain system safety and reliability. The modelling and simulation toolset HAGGIS provides methods for system specification and formal risk analysis. It provides a modelling framework for processes, fault trees and generic hazard specification and a physical world and maritime traffic simulation system. HAGGIS is accompanied by the physical test bed LABSKAUS which implements a physical test bed. The test bed provides reference ports and waterways in combination with an experimental Vessel Traffic Services (VTS system and a mobile integrated bridge: This enables in situ experiments for technological evaluation, testing, ground research and demonstration. This paper describes an integrated seamless approach for developing new e-navigation technologies starting with simulation based assessment and ending in physical real world demonstrations

  8. Accurate Multisteps Traffic Flow Prediction Based on SVM

    Directory of Open Access Journals (Sweden)

    Zhang Mingheng

    2013-01-01

    Full Text Available Accurate traffic flow prediction is prerequisite and important for realizing intelligent traffic control and guidance, and it is also the objective requirement for intelligent traffic management. Due to the strong nonlinear, stochastic, time-varying characteristics of urban transport system, artificial intelligence methods such as support vector machine (SVM are now receiving more and more attentions in this research field. Compared with the traditional single-step prediction method, the multisteps prediction has the ability that can predict the traffic state trends over a certain period in the future. From the perspective of dynamic decision, it is far important than the current traffic condition obtained. Thus, in this paper, an accurate multi-steps traffic flow prediction model based on SVM was proposed. In which, the input vectors were comprised of actual traffic volume and four different types of input vectors were compared to verify their prediction performance with each other. Finally, the model was verified with actual data in the empirical analysis phase and the test results showed that the proposed SVM model had a good ability for traffic flow prediction and the SVM-HPT model outperformed the other three models for prediction.

  9. Construction of an Arabic reading test for assessment of dyslexic children.

    Science.gov (United States)

    Abou El-Ella, Mahmoud Y; Sayed, Emam M; Farghaly, Wafaa M; Abdel-Haleem, Emad K; Hussein, Eman S

    2004-07-01

    Dyslexia is a specific language-based disorder of constitutional origin, characterized by difficulties in phonological processing. The Arabic language differs in many aspects from foreign languages and the few previously designed Arabic tests for assessment of dyslexia did not pay attention to phonological awareness problems. This necessitates the design of an Arabic test which could properly assign specific difficulties among Arabic reading dyslexic children, including phonological awareness as a major contributing factor for dyslexia. The study was carried out in Assiut City, Egypt, during the period from September 1999 to the end of January 2001. The newly designed Arabic Reading Test (ART) in this work passed through many stages. Firstly, test construction by 11 Arabic teachers (specific judges). Secondly it was applied, in a pilot study, to 50 normal students (9-10 years old) to ascertain clarity of the test. Then test standardization was proven through application on a second sample (n=252 students), and third sample (n=58 dyslexics). The reliability of the ART was proven by the test-retest method (r=0.913, pdyslexia among Arabic reading children. It has great value in predicting dyslexia even among preschool age Arabic speaking children, through assessment of their phonological awareness skills, and thus, remediation programs can be properly and early directed.

  10. The importance of data collection for timely and accurate risk assessment

    Science.gov (United States)

    Gilsenan, MB

    2017-09-01

    The European Food Safety Authority (EFSA) is responsible for food safety risk assessments at EU level. It provides independent scientific advice on risks associated with the food chain to support EU risk management decisions. Since its establishment, EFSA has amassed a wealth of data to underpin its risk assessments, such as food consumption data, monitoring data and experimental data. Increasing transparency of its risk assessments is a core objective of EFSA. EFSA aims to enhance the quality and transparency of its outputs by giving insofar as possible access to data and methods underpinning its scientific outputs. This paper provides an overview of the role of EFSA, its core data collections and their regulatory framework, as well as data quality and standardisation aspects. Finally, the paper elaborates on EFSA’s 2020 strategy in relation to data, and describes EFSA scientific data warehouse and Knowledge Junction in this regard.

  11. Accurate Evaluation of Quantum Integrals

    Science.gov (United States)

    Galant, D. C.; Goorvitch, D.; Witteborn, Fred C. (Technical Monitor)

    1995-01-01

    Combining an appropriate finite difference method with Richardson's extrapolation results in a simple, highly accurate numerical method for solving a Schrodinger's equation. Important results are that error estimates are provided, and that one can extrapolate expectation values rather than the wavefunctions to obtain highly accurate expectation values. We discuss the eigenvalues, the error growth in repeated Richardson's extrapolation, and show that the expectation values calculated on a crude mesh can be extrapolated to obtain expectation values of high accuracy.

  12. Self-Assessment in Pharmacy and Health Science Education and Professional Practice

    Science.gov (United States)

    Rose, Renee L.; Ried, L. Douglas; Brazeau, Gayle

    2010-01-01

    Self-assessment is an important skill necessary for continued development of a health care professional from student pharmacist throughout their professional career. This paper reviews the literature on student and practitioner self-assessment and whether this skill can be improved upon. Although self-assessment appears to be a skill that can be improved, both students and professionals continue to have difficulty with accurate self-assessment. Experts' external assessment of students should remain the primary method of testing skills and knowledge until self-assessment strategies improve. While self-assessment is important to lifelong learning, external assessment is also important for practitioners' continuing professional development. PMID:20798800

  13. Performance assessment of mass flow rate measurement capability in a large scale transient two-phase flow test system

    International Nuclear Information System (INIS)

    Nalezny, C.L.; Chapman, R.L.; Martinell, J.S.; Riordon, R.P.; Solbrig, C.W.

    1979-01-01

    Mass flow is an important measured variable in the Loss-of-Fluid Test (LOFT) Program. Large uncertainties in mass flow measurements in the LOFT piping during LOFT coolant experiments requires instrument testing in a transient two-phase flow loop that simulates the geometry of the LOFT piping. To satisfy this need, a transient two-phase flow loop has been designed and built. The load cell weighing system, which provides reference mass flow measurements, has been analyzed to assess its capability to provide the measurements. The analysis consisted of first performing a thermal-hydraulic analysis using RELAP4 to compute mass inventory and pressure fluctuations in the system and mass flow rate at the instrument location. RELAP4 output was used as input to a structural analysis code SAPIV which is used to determine load cell response. The computed load cell response was then smoothed and differentiated to compute mass flow rate from the system. Comparison between computed mass flow rate at the instrument location and mass flow rate from the system computed from the load cell output was used to evaluate mass flow measurement capability of the load cell weighing system. Results of the analysis indicate that the load cell weighing system will provide reference mass flows more accurately than the instruments now in LOFT

  14. Test-retest reliability of Brazilian version of Memorial Symptom Assessment Scale for assessing symptoms in cancer patients.

    Science.gov (United States)

    Menezes, Josiane Roberta de; Luvisaro, Bianca Maria Oliveira; Rodrigues, Claudia Fernandes; Muzi, Camila Drumond; Guimarães, Raphael Mendonça

    2017-01-01

    To assess the test-retest reliability of the Memorial Symptom Assessment Scale translated and culturally adapted into Brazilian Portuguese. The scale was applied in an interview format for 190 patients with various cancers type hospitalized in clinical and surgical sectors of the Instituto Nacional de Câncer José de Alencar Gomes da Silva and reapplied in 58 patients. Data from the test-retest were double typed into a Microsoft Excel spreadsheet and analyzed by the weighted Kappa. The reliability of the scale was satisfactory in test-retest. The weighted Kappa values obtained for each scale item had to be adequate, the largest item was 0.96 and the lowest was 0.69. The Kappa subscale was also evaluated and values were 0.84 for high frequency physic symptoms, 0.81 for low frequency physical symptoms, 0.81 for psychological symptoms, and 0.78 for Global Distress Index. High level of reliability estimated suggests that the process of measurement of Memorial Symptom Assessment Scale aspects was adequate. Avaliar a confiabilidade teste-reteste da versão traduzida e adaptada culturalmente para o português do Brasil do Memorial Symptom Assessment Scale. A escala foi aplicada em forma de entrevista em 190 pacientes com diversos tipos de câncer internados nos setores clínicos e cirúrgicos do Instituto Nacional de Câncer José de Alencar Gomes da Silva e reaplicada em 58 pacientes. Os dados dos testes-retestes foram inseridos num banco de dados por dupla digitação independente em Excel e analisados pelo Kappa ponderado. A confiabilidade da escala mostrou-se satisfatória nos testes-retestes. Os valores do Kappa ponderado obtidos para cada item da escala apresentaram-se adequados, sendo o maior item de 0,96 e o menor de 0,69. Também se avaliou o Kappa das subescalas, sendo de 0,84 para sintomas físicos de alta frequência, de 0,81 para sintomas físicos de baixa frequência, de 0,81 também para sintomas psicológicos, e de 0,78 para Índice Geral de Sofrimento

  15. Should we assess climate model predictions in light of severe tests?

    Science.gov (United States)

    Katzav, Joel

    2011-06-01

    According to Austro-British philosopher Karl Popper, a system of theoretical claims is scientific only if it is methodologically falsifiable, i.e., only if systematic attempts to falsify or severely test the system are being carried out [Popper, 2005, pp. 20, 62]. He holds that a test of a theoretical system is severe if and only if it is a test of the applicability of the system to a case in which the system's failure is likely in light of background knowledge, i.e., in light of scientific assumptions other than those of the system being tested [Popper, 2002, p. 150]. Popper counts the 1919 tests of general relativity's then unlikely predictions of the deflection of light in the Sun's gravitational field as severe. An implication of Popper's above condition for being a scientific theoretical system is the injunction to assess theoretical systems in light of how well they have withstood severe testing. Applying this injunction to assessing the quality of climate model predictions (CMPs), including climate model projections, would involve assigning a quality to each CMP as a function of how well it has withstood severe tests allowed by its implications for past, present, and nearfuture climate or, alternatively, as a function of how well the models that generated the CMP have withstood severe tests of their suitability for generating the CMP.

  16. Functional, Structural, and Neurotoxicity Biomarkers in Integrative Assessment of Concussions

    Directory of Open Access Journals (Sweden)

    Svetlana A Dambinova

    2016-10-01

    Full Text Available Concussion is a complex, heterogenous process affecting the brain. Accurate assessment and diagnosis and appropriate management of concussion are essential to ensure athletes do not prematurely return to play or others to work or active military duty, risking re-injury. To date, clinical diagnosis relies primarily on evaluating subjects for functional impairment using instruments that include neurocognitive testing, subjective symptom report, and neurobehavioral assessments, such as balance and vestibular-ocular reflex testing. Structural biomarkers, defined as advanced neuroimaging techniques and biomarkers assessing neurotoxicity and immunoexcitotoxicity may complement the use of functional biomarkers. We hypothesize that neurotoxicity AMPA, NMDA, and kainite receptor biomarkers might be utilized as a part of comprehensive approach to concussion evaluations, with the goal of increasing diagnostic accuracy and facilitating treatment planning and prognostic assessment.

  17. The Empirical Testing of a Musical Performance Assessment Paradigm

    Science.gov (United States)

    Russell, Brian E.

    2010-01-01

    The purpose of this study was to test a hypothesized model of aurally perceived performer-controlled musical factors that influence assessments of performance quality. Previous research studies on musical performance constructs, musical achievement, musical expression, and scale construction were examined to identify the factors that influence…

  18. Pilot evaluation of the Computer-Based Assessment for Sampling Personal Characteristics test.

    Science.gov (United States)

    Shipper, Edward S; Mazer, Laura M; Merrell, Sylvia Bereknyei; Lin, Dana T; Lau, James N; Melcher, Marc L

    2017-07-01

    High attrition rates hint at deficiencies in the resident selection process. The evaluation of personal characteristics representative of success is difficult. Here, we evaluate a novel tool for assessing personal characteristics. To evaluate feasibility, we used an anonymous voluntary survey questionnaire offered to study participants before and after contact with the CASPer test. To evaluate the CASPer test as a predictor of success, we compared CASPer test assessments of personal characteristics versus traditional faculty assessment of personal characteristics with applicant rank list position. All applicants (n = 77) attending an in-person interview for general surgery residency, and all faculty interviewers (n = 34) who reviewed these applications were invited to participate. Among applicants, 84.4% of respondents (65 of 77) reported that a requirement to complete the CASPer test would have no bearing or would make them more likely to apply to the program (mean = 3.30, standard deviation = 0.96). Among the faculty, 62.5% respondents (10 of 16) reported that the same condition would have no bearing or would make applicants more likely to apply to the program (mean = 3.19, standard deviation = 1.33). The Spearman's rank-order correlation coefficients for the relationships between traditional faculty assessment of personal characteristics and applicant rank list position, and novel CASPer assessment of personal characteristics and applicant rank list position, were -0.45 (P = 0.033) and -0.41 (P = 0.055), respectively. The CASPer test may be feasibly implemented as component of the resident selection process, with the potential to predict applicant rank list position and improve the general surgery resident selection process. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Unilateral Arm Crank Exercise Test for Assessing Cardiorespiratory Fitness in Individuals with Hemiparetic Stroke

    DEFF Research Database (Denmark)

    Oyake, Kazuaki; Yamaguchi, Tomofumi; Oda, Chihiro

    2017-01-01

    Cardiorespiratory fitness assessment with leg cycle exercise testing may be influenced by motor impairments in the paretic lower extremity. Hence, this study examined the usefulness of a unilateral arm crank exercise test to assess cardiorespiratory fitness in individuals with stroke, including s...

  20. 78 FR 49287 - Environmental Assessment for Potential Lease Issuance and Marine Hydrokinetic Technology Testing...

    Science.gov (United States)

    2013-08-13

    ...; MMAA104000] Environmental Assessment for Potential Lease Issuance and Marine Hydrokinetic Technology Testing... important environmental issues associated with data collection and technology testing activities (76 FR... Availability of a Revised Environmental Assessment and a Finding of No Significant Impact. SUMMARY: BOEM has...

  1. Mini-Mental Status Examination: a short form of MMSE was as accurate as the original MMSE in predicting dementia

    DEFF Research Database (Denmark)

    Schultz-Larsen, Kirsten; Lomholt, Rikke Kirstine; Kreiner, Svend

    2006-01-01

    .4%), and positive predictive value (71.0%) but equal area under the receiver operating characteristic curve. Cross-validation on follow-up data confirmed the results. CONCLUSION: A short, valid MMSE, which is as sensitive and specific as the original MMSE for the screening of cognitive impairments and dementia......OBJECTIVES: This study assesses the properties of the Mini-Mental State Examination (MMSE) with the purpose of improving the efficiencies of the methods of screening for cognitive impairment and dementia. A specific purpose was to determine whether an abbreviated version would be as accurate...... is attractive for research and clinical practice, particularly if predictive power can be enhanced by combining the short MMSE with neuropsychological tests or informant reports....

  2. Validity of Montreal Cognitive Assessment in non-english speaking patients with Parkinson's disease.

    Science.gov (United States)

    Krishnan, Syam; Justus, Sunitha; Meluveettil, Radhamani; Menon, Ramshekhar N; Sarma, Sankara P; Kishore, Asha

    2015-01-01

    The Montreal Cognitive Assessment is a brief and easy screening tool for accurately testing cognitive dysfunction in Parkinson's disease. We tested its validity for use in non-English (Malayalam) speaking patients with Parkinson's disease. We developed a Malayalam (a south-Indian language) version of Montreal Cognitive Assessment and applied to 70 patients with Parkinson's disease and 60 age- and education-matched healthy controls. Metric properties were assessed, and the scores were compared with the performance in validated Malayalam versions of Mini Mental Status Examination and Addenbrooke's Cognitive Examination. The Montreal Cognitive Assessment-Malayalam showed good internal consistency and test-retest reliability and its scores correlated with Mini Mental Status Examination (patients: R = 0.70; P speaking Parkinson's disease patients for early screening and potential future interventions for cognitive dysfunction.

  3. Approaching system equilibrium with accurate or not accurate feedback information in a two-route system

    Science.gov (United States)

    Zhao, Xiao-mei; Xie, Dong-fan; Li, Qi

    2015-02-01

    With the development of intelligent transport system, advanced information feedback strategies have been developed to reduce traffic congestion and enhance the capacity. However, previous strategies provide accurate information to travelers and our simulation results show that accurate information brings negative effects, especially in delay case. Because travelers prefer to the best condition route with accurate information, and delayed information cannot reflect current traffic condition but past. Then travelers make wrong routing decisions, causing the decrease of the capacity and the increase of oscillations and the system deviating from the equilibrium. To avoid the negative effect, bounded rationality is taken into account by introducing a boundedly rational threshold BR. When difference between two routes is less than the BR, routes have equal probability to be chosen. The bounded rationality is helpful to improve the efficiency in terms of capacity, oscillation and the gap deviating from the system equilibrium.

  4. Wind Resource Assessment – Østerild National Test Centre for Large Wind Turbines

    OpenAIRE

    Hansen, Brian Ohrbeck; Courtney, Michael; Mortensen, Niels Gylling

    2014-01-01

    This report presents a wind resource assessment for the seven test stands at the Østerild National Test Centre for Large Wind Turbines in Denmark. Calculations have been carried out mainly using wind data from three on-site wind lidars. The generalized wind climates applied in the wind resource calculations for the seven test stands are based on correlations between a short period of on-site wind data from the wind lidars with a long-term reference. The wind resource assessment for the seven ...

  5. SU-E-T-373: A Motorized Stage for Fast and Accurate QA of Machine Isocenter

    International Nuclear Information System (INIS)

    Moore, J; Velarde, E; Wong, J

    2014-01-01

    Purpose: Precision delivery of radiation dose relies on accurate knowledge of the machine isocenter under a variety of machine motions. This is typically determined by performing a Winston-Lutz test consisting of imaging a known object at multiple gantry/collimator/table angles and ensuring that the maximum offset is within specified tolerance. The first step in the Winston-Lutz test is careful placement of a ball bearing at the machine isocenter as determined by repeated imaging and shifting until accurate placement has been determined. Conventionally this is performed by adjusting a stage manually using vernier scales which carry the limitation that each adjustment must be done inside the treatment room with the risks of inaccurate adjustment of the scale and physical bumping of the table. It is proposed to use a motorized system controlled outside of the room to improve the required time and accuracy of these tests. Methods: The three dimensional vernier scales are replaced by three motors with accuracy of 1 micron and a range of 25.4mm connected via USB to a computer in the control room. Software is designed which automatically detects the motors and assigns them to proper axes and allows for small shifts to be entered and performed. Input values match calculated offsets in magnitude and sign to reduce conversion errors. Speed of setup, number of iterations to setup, and accuracy of final placement are assessed. Results: Automatic BB placement required 2.25 iterations and 13 minutes on average while manual placement required 3.76 iterations and 37.5 minutes. The average final XYZ offsets is 0.02cm, 0.01cm, 0.04cm for automatic setup and 0.04cm, 0.02cm, 0.04cm for manual setup. Conclusion: Automatic placement decreased time and repeat iterations for setup while improving placement accuracy. Automatic placement greatly reduces the time required to perform QA

  6. Internal Medicine Residents Do Not Accurately Assess Their Medical Knowledge

    Science.gov (United States)

    Jones, Roger; Panda, Mukta; Desbiens, Norman

    2008-01-01

    Background: Medical knowledge is essential for appropriate patient care; however, the accuracy of internal medicine (IM) residents' assessment of their medical knowledge is unknown. Methods: IM residents predicted their overall percentile performance 1 week (on average) before and after taking the in-training exam (ITE), an objective and well…

  7. Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.

    Science.gov (United States)

    Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin

    2015-02-01

    The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.

  8. Assessment of TRACE Condensation Model Against Reflux Condensation Tests with Noncondensable Gases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Won; Cheong, Ae Ju; Shin, Andong; Suh, Nam Duk [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-05-15

    The TRACE is the latest in a series of advanced, best-estimated reactor systems code developed by U.S. Nuclear Regulatory Commission for analyzing transient and steady-state neutronic-thermal-hydraulic behavior in light water reactors. This special model is expected to replace the default model in a future code release after sufficient testing has been completed. This study assesses the special condensation model of TRACE 5.0-patch4 against the counter-current flow configuration. For this purpose, the predicted results of special model are compared to the experimental and to those of default model. The KAST reflux condensation test with NC gases are used in this assessment. We assessed the special model for film condensation of TRACE 5.0-patch4 against the data of the reflux condensation test in the presence of NC gases. The special condensation model of TRACE provides a reasonable estimate of HTC with good agreement at the low inlet steam flow rate.

  9. Assessment of TRACE Condensation Model Against Reflux Condensation Tests with Noncondensable Gases

    International Nuclear Information System (INIS)

    Lee, Kyung Won; Cheong, Ae Ju; Shin, Andong; Suh, Nam Duk

    2015-01-01

    The TRACE is the latest in a series of advanced, best-estimated reactor systems code developed by U.S. Nuclear Regulatory Commission for analyzing transient and steady-state neutronic-thermal-hydraulic behavior in light water reactors. This special model is expected to replace the default model in a future code release after sufficient testing has been completed. This study assesses the special condensation model of TRACE 5.0-patch4 against the counter-current flow configuration. For this purpose, the predicted results of special model are compared to the experimental and to those of default model. The KAST reflux condensation test with NC gases are used in this assessment. We assessed the special model for film condensation of TRACE 5.0-patch4 against the data of the reflux condensation test in the presence of NC gases. The special condensation model of TRACE provides a reasonable estimate of HTC with good agreement at the low inlet steam flow rate

  10. Comparison of Classical Test Theory and Item Response Theory in Individual Change Assessment

    NARCIS (Netherlands)

    Jabrayilov, Ruslan; Emons, Wilco H. M.; Sijtsma, Klaas

    2016-01-01

    Clinical psychologists are advised to assess clinical and statistical significance when assessing change in individual patients. Individual change assessment can be conducted using either the methodologies of classical test theory (CTT) or item response theory (IRT). Researchers have been optimistic

  11. Image quality assessment using deep convolutional networks

    Science.gov (United States)

    Li, Yezhou; Ye, Xiang; Li, Yong

    2017-12-01

    This paper proposes a method of accurately assessing image quality without a reference image by using a deep convolutional neural network. Existing training based methods usually utilize a compact set of linear filters for learning features of images captured by different sensors to assess their quality. These methods may not be able to learn the semantic features that are intimately related with the features used in human subject assessment. Observing this drawback, this work proposes training a deep convolutional neural network (CNN) with labelled images for image quality assessment. The ReLU in the CNN allows non-linear transformations for extracting high-level image features, providing a more reliable assessment of image quality than linear filters. To enable the neural network to take images of any arbitrary size as input, the spatial pyramid pooling (SPP) is introduced connecting the top convolutional layer and the fully-connected layer. In addition, the SPP makes the CNN robust to object deformations to a certain extent. The proposed method taking an image as input carries out an end-to-end learning process, and outputs the quality of the image. It is tested on public datasets. Experimental results show that it outperforms existing methods by a large margin and can accurately assess the image quality on images taken by different sensors of varying sizes.

  12. The Sally-Anne Test: An Interactional Analysis of a Dyadic Assessment

    Science.gov (United States)

    Korkiakangas, Terhi; Dindar, Katja; Laitila, Aarno; Kärnä, Eija

    2016-01-01

    Background: The Sally-Anne test has been extensively used to examine children's theory of mind understanding. Many task-related factors have been suggested to impact children's performance on this test. Yet little is known about the interactional aspects of such dyadic assessment situations that might contribute to the ways in which children…

  13. Advanced Marketing Core Curriculum. Test Items and Assessment Techniques.

    Science.gov (United States)

    Smith, Clifton L.; And Others

    This document contains duties and tasks, multiple-choice test items, and other assessment techniques for Missouri's advanced marketing core curriculum. The core curriculum begins with a list of 13 suggested textbook resources. Next, nine duties with their associated tasks are given. Under each task appears one or more citations to appropriate…

  14. Accurate assessment of long-term nephrotoxicity after peptide receptor radionuclide therapy with 177Lu-octreotate

    International Nuclear Information System (INIS)

    Sabet, Amir; Ezziddin, Khaled; Reichman, Karl; Haslerud, Torjan; Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen; Ezziddin, Samer; Pape, Ulrich-Frank; Nagarajah, James

    2014-01-01

    Renal radiation during peptide receptor radionuclide therapy (PRRT) may result in glomerular damage, a potential reduction of glomerular filtration rate (GFR) and ultimately lead to renal failure. While reported PRRT nephrotoxicity is limited to data derived from serum creatinine - allowing only approximate estimates of GFR - the aim of this study is to accurately determine PRRT-induced long-term changes of renal function and associated risk factors according to state-of-the-art GFR measurement. Nephrotoxicity was analysed using 99m Tc-diethylenetriaminepentaacetic acid (DTPA) clearance data of 74 consecutive patients with gastroenteropancreatic neuroendocrine tumours (GEP NET) undergoing PRRT with 177 Lu-octreotate. The mean follow-up period was 21 months (range 12-50) with a median of five GFR measurements per patient. The change of GFR was analysed by linear curve fit. Potential risk factors including diabetes mellitus, arterial hypertension, previous chemotherapy, renal impairment at baseline and cumulative administered activity were analysed regarding potential impact on renal function loss. In addition, Common Terminology Criteria for Adverse Events (CTCAE) v3.0 were used to compare nephrotoxicity determined by 99m Tc-DTPA clearance versus serum creatinine. The alteration in GFR differed widely among the patients (mean -2.1 ± 13.1 ml/min/m 2 per year, relative yearly reduction -1.8 ± 18.9 %). Fifteen patients (21 %) experienced a mild (2-10 ml/min/m 2 per year) and 16 patients (22 %) a significant (>10 ml/min/m 2 per year) decline of GFR following PRRT. However, 11 patients (15 %) showed an increase of >10 ml/min/m 2 per year. Relevant nephrotoxicity according to CTCAE (grade ≥3) was observed in one patient (1.3 %) with arterial hypertension and history of chemotherapy. Nephrotoxicity according to serum creatinine was discordant to that defined by GFR in 15 % of the assessments and led to underestimation in 12 % of patients. None of the investigated

  15. A virtual reality test battery for assessment and screening of spatial neglect.

    Science.gov (United States)

    Fordell, H; Bodin, K; Bucht, G; Malm, J

    2011-03-01

    There is a need for improved screening methods for spatial neglect. To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke. VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11. Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r² = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47-0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was 'easy' to use. Eighty-eight percent reported that they felt 'focused', 'pleased' or 'alert'. No patient had adverse symptoms. The test session took 15 min. The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment. © 2010 John Wiley & Sons A/S.

  16. Comparison between young male drivers' self-assessed and objectively measured driving skills

    DEFF Research Database (Denmark)

    Martinussen, Laila Marianne; Møller, Mette; Prato, Carlo Giacomo

    2017-01-01

    Self-assessment of skills is a self-generated feedback process that contributes to confidence in one's skills. The higher one's self-assessed skills, the more likely one is to feel competent a particular domain thereby influencing the related behaviors. Drivers' self-assessed driving skills...... are not always accurate, which may cause serious problems such as underestimation of risk, reckless driving and accidents. Most previous research on self-assessment of driving skills did not compare self-reported skills to objectively measured driving skills, so the aim of this study was to test the accuracy...

  17. Revising the ADAS-cog for a more accurate assessment of cognitive impairment

    NARCIS (Netherlands)

    Wouters, Hans; van Gool, Willem A; Schmand, Ben; Lindeboom, Robert

    2008-01-01

    BACKGROUND: To examine whether it is appropriate to sum the cognitive part of the Alzheimer Disease Assessment Scale (ADAS-cog) items to assess cognitive impairment. This assumes items to have (1) equal measurement precision and (2) hierarchically ordered categories. METHODS: Rasch analysis on the

  18. Brazilian preliminary norms and investigation of age and education effects on the Modified Wisconsin Card Sorting Test, Stroop Color and Word test and Digit Span test in adults

    Science.gov (United States)

    Zimmermann, Nicolle; Cardoso, Caroline de Oliveira; Trentini, Clarissa Marceli; Grassi-Oliveira, Rodrigo; Fonseca, Rochele Paz

    2015-01-01

    Executive functions are involved in a series of human neurological and psychiatric disorders. For this reason, appropriate assessment tools with age and education adjusted norms for symptom diagnosis are necessary. Objective To present normative data for adults (19-75 year-olds; with five years of education or more) on the Modified Wisconsin Card Sorting Test (MWCST), Stroop color and word test and Digit Span test. Age and education effects were investigated. Methods Three samples were formed after inclusion criteria and data analysis: MWCST (n=124); Digit Span (n=123), and Stroop test (n=158). Groups were divided into young (19-39), middle-aged (40-59) and older (60-75) participants with five to eight years of education and nine years of education or more. Two-way ANOVA and ANCOVA analyses were used. Results Education effects were found in most variables of the three tasks. An age effect was only found on color naming and color-word naming speed from the Stroop test. No interactions were detected. Conclusion In countries with heterogeneous educational backgrounds, the use of stratified norms by education to assess at least some components of executive functions is essential for an ethical and accurate cognitive diagnosis. PMID:29213953

  19. Assessment of the Nevada Test Site as a Site for Distributed Resource Testing and Project Plan: March 2002

    Energy Technology Data Exchange (ETDEWEB)

    Horgan, S.; Iannucci, J.; Whitaker, C.; Cibulka, L.; Erdman, W.

    2002-05-01

    The objective of this project was to evaluate the Nevada Test Site (NTS) as a location for performing dedicated, in-depth testing of distributed resources (DR) integrated with the electric distribution system. In this large scale testing, it is desired to operate multiple DRs and loads in an actual operating environment, in a series of controlled tests to concentrate on issues of interest to the DR community. This report includes an inventory of existing facilities at NTS, an assessment of site attributes in relation to DR testing requirements, and an evaluation of the feasibility and cost of upgrades to the site that would make it a fully qualified DR testing facility.

  20. A Short Test for the Assessment of Basic Knowledge in Psychology

    Science.gov (United States)

    Peter, Johannes; Leichner, Nikolas; Mayer, Anne-Kathrin; Krampen, Günter

    2015-01-01

    This paper reports the development of a fixed-choice test for the assessment of basic knowledge in psychology, for use with undergraduate as well as graduate students. Test content is selected based on a core concepts approach and includes a sample of concepts which are indexed most frequently in common introductory psychology textbooks. In a…

  1. Self-Assessment in Coursework Essays.

    Science.gov (United States)

    Longhurst, Nigel; Norton, Lin S.

    1997-01-01

    Self-assessments of coursework essays were compared with tutor grades for 67 college students. Students could accurately assess their overall essay grades and could give an overall rank for deep processing, but when judging essays on individual criteria they were not so accurate when compared to tutor evaluations. (SLD)

  2. Accuracy, precision, usability, and cost of portable silver test methods for ceramic filter factories.

    Science.gov (United States)

    Meade, Rhiana D; Murray, Anna L; Mittelman, Anjuliee M; Rayner, Justine; Lantagne, Daniele S

    2017-02-01

    Locally manufactured ceramic water filters are one effective household drinking water treatment technology. During manufacturing, silver nanoparticles or silver nitrate are applied to prevent microbiological growth within the filter and increase bacterial removal efficacy. Currently, there is no recommendation for manufacturers to test silver concentrations of application solutions or filtered water. We identified six commercially available silver test strips, kits, and meters, and evaluated them by: (1) measuring in quintuplicate six samples from 100 to 1,000 mg/L (application range) and six samples from 0.0 to 1.0 mg/L (effluent range) of silver nanoparticles and silver nitrate to determine accuracy and precision; (2) conducting volunteer testing to assess ease-of-use; and (3) comparing costs. We found no method accurately detected silver nanoparticles, and accuracy ranged from 4 to 91% measurement error for silver nitrate samples. Most methods were precise, but only one method could test both application and effluent concentration ranges of silver nitrate. Volunteers considered test strip methods easiest. The cost for 100 tests ranged from 36 to 1,600 USD. We found no currently available method accurately and precisely measured both silver types at reasonable cost and ease-of-use, thus these methods are not recommended to manufacturers. We recommend development of field-appropriate methods that accurately and precisely measure silver nanoparticle and silver nitrate concentrations.

  3. Linking the Virginia SOL Assessments to NWEA MAP Tests

    Science.gov (United States)

    Northwest Evaluation Association, 2016

    2016-01-01

    Northwest Evaluation Association™ (NWEA™) is committed to providing partners with useful tools to help make inferences from the Measures of Academic Progress® (MAP®) interim assessment scores. Recently, NWEA completed a concordance study to connect the scales of the Virginia Standards of Learning (SOL) reading and math tests with those of the MAP…

  4. Nigeria; Publication of Financial Sector Assessment Program Documentation––Technical Note on Stress Testing

    OpenAIRE

    International Monetary Fund

    2013-01-01

    To assess the financial stability in Nigeria, various stress tests and analytic processes were undertaken jointly by the Nigerian authorities and the Financial Sector Assessment Program (FSAP) team. The exercise included macroeconomic scenario analysis and its transmission into a range of single- and multifactor shocks. The tests covered the entire Nigerian banking system and looked at the short-term horizon, in part because of data constraints. Sensitivity stress tests estimated the impact o...

  5. Less Truth Than Error: Massachusetts Teacher Tests

    Directory of Open Access Journals (Sweden)

    Walt Haney

    1999-02-01

    Full Text Available Scores on the Massachusetts Teacher Tests of reading and writing are highly unreliable. The tests' margin of error is close to double to triple the range found on well-developed tests. A person retaking the MTT several times could have huge fluctuations in their scores even if their skill level did not change significantly. In fact, the 9 to 17 point margin of error calculated for the tests represents more than 10 percent of the grading scale (assumed to be 0 to 100. The large margin of error means there is both a high false-pass rate and a high false-failure rate. For example, a person who received a score of 72 on the writing test could have scored an 89 or a 55 simply because of the unreliability of the test. Since adults' reading and writing skills do not change a great deal over several months, this range of scores on the same test should not be possible. While this test is being touted as an accurate assessment of a person's fitness to be a teacher, one would expect the scores to accurately reflect a test-taker's verbal ability level. In addition to the large margin of error, the MTT contain questionable content that make them poor tools for measuring test-takers' reading and writing skills. The content and lack of correlation between the reading and writing scores reduces the meaningfulness, or validity, of the tests. The validity is affected not just by the content, but by a host of factors, such as the conditions under which tests were administered and how they were scored. Interviews with a small sample of test-takers confirmed published reports concerning problems with the content and administration.

  6. A highly accurate algorithm for the solution of the point kinetics equations

    International Nuclear Information System (INIS)

    Ganapol, B.D.

    2013-01-01

    Highlights: • Point kinetics equations for nuclear reactor transient analysis are numerically solved to extreme accuracy. • Results for classic benchmarks found in the literature are given to 9-digit accuracy. • Recent results of claimed accuracy are shown to be less accurate than claimed. • Arguably brings a chapter of numerical evaluation of the PKEs to a close. - Abstract: Attempts to resolve the point kinetics equations (PKEs) describing nuclear reactor transients have been the subject of numerous articles and texts over the past 50 years. Some very innovative methods, such as the RTS (Reactor Transient Simulation) and CAC (Continuous Analytical Continuation) methods of G.R. Keepin and J. Vigil respectively, have been shown to be exceptionally useful. Recently however, several authors have developed methods they consider accurate without a clear basis for their assertion. In response, this presentation will establish a definitive set of benchmarks to enable those developing PKE methods to truthfully assess the degree of accuracy of their methods. Then, with these benchmarks, two recently published methods, found in this journal will be shown to be less accurate than claimed and a legacy method from 1984 will be confirmed

  7. The "moving valgus stress test" for medial collateral ligament tears of the elbow.

    Science.gov (United States)

    O'Driscoll, Shawn W M; Lawton, Richard L; Smith, Adam M

    2005-02-01

    The diagnosis of a painful partial tear of the medial collateral ligament in overhead-throwing athletes is challenging, even for experienced elbow surgeons and despite the use of sophisticated imaging techniques. The "moving valgus stress test" is an accurate physical examination technique for diagnosis of medial collateral ligament attenuation in the elbow. Cohort study (diagnosis); Level of evidence, 2. Twenty-one patients underwent surgical intervention for medial elbow pain due to medial collateral ligament insufficiency or other abnormality of chronic valgus overload, and they were assessed preoperatively with an examination called the moving valgus stress test. To perform the moving valgus stress test, the examiner applies and maintains a constant moderate valgus torque to the fully flexed elbow and then quickly extends the elbow. The test is positive if the medial elbow pain is reproduced at the medial collateral ligament and is at maximum between 120 degrees and 70 degrees. The moving valgus stress test was highly sensitive (100%, 17 of 17 patients) and specific (75%, 3 of 4 patients) when compared to assessment of the medial collateral ligament by surgical exploration or arthroscopic valgus stress testing. The mean shear range (ie, the arc within which pain was produced with the moving valgus stress test) was 120 degrees to 70 degrees. The mean angle at which pain was at a maximum was 90 degrees of elbow flexion. The moving valgus stress test is an accurate physical examination technique that, when performed and interpreted correctly, is highly sensitive for medial elbow pain arising from the medial collateral ligament.

  8. Expanding Horizons and Unresolved Conundrums: Language Testing and Assessment

    Science.gov (United States)

    Leung, Constant; Lewkowicz, Jo

    2006-01-01

    Since the last "TESOL Quarterly" commemorative issue 15 years ago, there have been too many important developments in language testing and assessment for all of them to be discussed in a single article. Therefore, this article focuses on issues that we believe are integrally linked to pedagogic and curriculum concerns of English language teaching.…

  9. Pilot Test of an Innovative Interprofessional Education Assessment Strategy

    Science.gov (United States)

    Emmert, Michelle Christine

    2011-01-01

    The primary goal of this study was to test an innovative way of assessing students' teamwork skills in a controlled environment. Twenty-four second year students from Western University of Health Sciences (WesternU) participated in the experimental group and 22 third year students from WesternU participated in the control group. Students in the…

  10. Comparative assessment of seller's staining test (SST) and direct ...

    African Journals Online (AJOL)

    the only standard method. Objective: This study was designed to assess the sensitivity and specificity of the SST in relation to the 'gold standard' dFAT in diagnosis of rabies in Nigeria. Methods: A total of 88 animal specimens submitted to the Rabies National Reference Laboratory, Nigeria were routinely tested for rabies by ...

  11. The SPECIES and ORGANISMS Resources for Fast and Accurate Identification of Taxonomic Names in Text

    DEFF Research Database (Denmark)

    Pafilis, Evangelos; Pletscher-Frankild, Sune; Fanini, Lucia

    2013-01-01

    The exponential growth of the biomedical literature is making the need for efficient, accurate text-mining tools increasingly clear. The identification of named biological entities in text is a central and difficult task. We have developed an efficient algorithm and implementation of a dictionary......-based approach to named entity recognition, which we here use to identify names of species and other taxa in text. The tool, SPECIES, is more than an order of magnitude faster and as accurate as existing tools. The precision and recall was assessed both on an existing gold-standard corpus and on a new corpus...

  12. The effect of external dynamic loads on the lifetime of rolling element bearings: accurate measurement of the bearing behaviour

    International Nuclear Information System (INIS)

    Jacobs, W; Boonen, R; Sas, P; Moens, D

    2012-01-01

    Accurate prediction of the lifetime of rolling element bearings is a crucial step towards a reliable design of many rotating machines. Recent research emphasizes an important influence of external dynamic loads on the lifetime of bearings. However, most lifetime calculations of bearings are based on the classical ISO 281 standard, neglecting this influence. For bearings subjected to highly varying loads, this leads to inaccurate estimations of the lifetime, and therefore excessive safety factors during the design and unexpected failures during operation. This paper presents a novel test rig, developed to analyse the behaviour of rolling element bearings subjected to highly varying loads. Since bearings are very precise machine components, their motion can only be measured in an accurately controlled environment. Otherwise, noise from other components and external influences such as temperature variations will dominate the measurements. The test rig is optimised to perform accurate measurements of the bearing behaviour. Also, the test bearing is fitted in a modular structure, which guarantees precise mounting and allows testing different types and sizes of bearings. Finally, a fully controlled multi-axial static and dynamic load is imposed on the bearing, while its behaviour is monitored with capacitive proximity probes.

  13. Properties of the COPD assessment test in a cross-sectional European study

    NARCIS (Netherlands)

    Jones, P. W.; Brusselle, G.; Dal Negro, R. W.; Ferrer, M.; Kardos, P.; Levye, M. L.; Perez, T.; Cataluna, J. J. Soler; van der Molen, T.; Adamek, L.; Banik, N.

    A short, easy-to-use health status questionnaire is needed in the multidimensional assessment of chronic obstructive pulmonary disease (COPD) in routine practice. The performance of the eight-item COPD assessment test (CAT) was analysed in 1,817 patients from primary care in seven European

  14. Military Ecological Risk Assessment Framework (MERAF) for Assessment of Risks of Military Training and Testing to Natural Resources

    Energy Technology Data Exchange (ETDEWEB)

    Suter II, G.W.

    2003-06-18

    The objective of this research is to provide the DoD with a framework based on a systematic, risk-based approach to assess impacts for management of natural resources in an ecosystem context. This risk assessment framework is consistent with, but extends beyond, the EPA's ecological risk assessment framework, and specifically addresses DoD activities and management needs. MERAF is intended to be consistent with existing procedures for environmental assessment and planning with DoD testing and training. The intention is to supplement these procedures rather than creating new procedural requirements. MERAF is suitable for use for training and testing area assessment and management. It does not include human health risks nor does it address specific permitting or compliance requirements, although it may be useful in some of these cases. Use of MERAF fits into the National Environmental Policy Act (NEPA) process by providing a consistent and rigorous way of organizing and conducting the technical analysis for Environmental Impact Statements (EISs) (Sigal 1993; Carpenter 1995; Canter and Sadler 1997). It neither conflicts with, nor replaces, procedural requirements within the NEPA process or document management processes already in place within DoD.

  15. Assessment of Current Practice for Tank Testing of Small Marine Energy Devices

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    Discussion Report. Equitable Testing and Evaluation of Marine Energy Extraction Devices in terms of Performance, Cost and Environmental Impact. The report is a contribution by Aalborg University (AAU) to the deliverable on Assessment of current practice for tank testing of small marine energy...

  16. Modification of Harvard step-test for assessment of students’ with health problems functional potentials

    Directory of Open Access Journals (Sweden)

    E.N. Kopeikina

    2016-08-01

    Full Text Available Purpose: to substantiate, work out and experimentally prove modified test for assessment of students’ with health problems functional potentials. Material: in the research students and girl students of 18-20 years’ age (n=522 participated. According to the worked out modification of test during 30 seconds student ascended on bench (h=43 cm and descended from it. Then pulse was measured three times. In total the test took 4 minutes. Results: For working out the scale for interpretation of the received results we assessed new 30 seconds’ modification of Harvard step-test for validity. First, for this purpose all students fulfilled modified step-test. Then after full restoration (after 20 minutes they fulfilled its three minutes’ variant. Correlation analysis of the received results showed the presence of average correlation between two samples (r=0.64. Conclusions: application of this modified variant permits for pedagogues to completely assess functional potentials of students with heath problems.

  17. A virtual shopping test for realistic assessment of cognitive function.

    Science.gov (United States)

    Okahashi, Sayaka; Seki, Keiko; Nagano, Akinori; Luo, Zhiwei; Kojima, Maki; Futaki, Toshiko

    2013-06-18

    Cognitive dysfunction caused by brain injury often prevents a patient from achieving a healthy and high quality of life. By now, each cognitive function is assessed precisely by neuropsychological tests. However, it is also important to provide an overall assessment of the patients' ability in their everyday life. We have developed a Virtual Shopping Test (VST) using virtual reality technology. The objective of this study was to clarify 1) the significance of VST by comparing VST with other conventional tests, 2) the applicability of VST to brain-damaged patients, and 3) the performance of VST in relation to age differences. The participants included 10 patients with brain damage, 10 age-matched healthy subjects for controls, 10 old healthy subjects, and 10 young healthy subjects. VST and neuropsychological tests/questionnaires about attention, memory and executive function were conducted on the patients, while VST and the Mini-Mental State Examination (MMSE) were conducted on the controls and healthy subjects. Within the VST, the participants were asked to buy four items in the virtual shopping mall quickly in a rational way. The score for evaluation included the number of items bought correctly, the number of times to refer to hints, the number of movements between shops, and the total time spent to complete the shopping. Some variables on VST correlated with the scores of conventional assessment about attention and everyday memory. The mean number of times referring to hints and the mean number of movements were significantly larger for the patients with brain damage, and the mean total time was significantly longer for the patients than for the controls. In addition, the mean total time was significantly longer for the old than for the young. The results suggest that VST is able to evaluate the ability of attention and everyday memory in patients with brain damage. The time of VST is increased by age.

  18. Absorbable magnesium-based stent: physiological factors to consider for in vitro degradation assessments.

    Science.gov (United States)

    Wang, Juan; Smith, Christopher E; Sankar, Jagannathan; Yun, Yeoheung; Huang, Nan

    2015-03-01

    Absorbable metals have been widely tested in various in vitro settings using cells to evaluate their possible suitability as an implant material. However, there exists a gap between in vivo and in vitro test results for absorbable materials. A lot of traditional in vitro assessments for permanent materials are no longer applicable to absorbable metallic implants. A key step is to identify and test the relevant microenvironment and parameters in test systems, which should be adapted according to the specific application. New test methods are necessary to reduce the difference between in vivo and in vitro test results and provide more accurate information to better understand absorbable metallic implants. In this investigative review, we strive to summarize the latest test methods for characterizing absorbable magnesium-based stent for bioabsorption/biodegradation behavior in the mimicking vascular environments. Also, this article comprehensively discusses the direction of test standardization for absorbable stents to paint a more accurate picture of the in vivo condition around implants to determine the most important parameters and their dynamic interactions.

  19. A quantitative assessment of the weakening of wire ropes based on the magnetic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kwasniewski, J.; Lankosz, L.; Tytko, A.

    1985-01-01

    Discusses the use of magnetic defectoscopes and defectographs in the nondestructive testing of wire ropes. Emphasizes the need for laboratory pre-calibration where quantitave results are required. Individual system calibration is recommended where instruments with a 95% confidence level in reading are used, e.g. MD-8 defectograph and DLS unit, but improved tolerances achieved in sensor head manufacture have made possible a universal calibration characteristic for use with defectoscopes and a wide variety of heads. A chart is given covering all heads and induction sensors available in Poland. Describes methods of interpreting presented results to indicate degree of wear due to fatigue, abrasion and corrosion in ropes with constituent wires of differing profile. States that the form of rope wear can be deduced from the character of the defectograph pulse readings. Formulae relating the degree of rope weakening to these readings and also to the integrated output are given. Briefly describes a method for determining the loss of rope cross sectional area based on Hall effect chart records. Outlines the use of the MD-9 and MD-10 defectoscopes in assessing rope wear in discrete ranges. Suggests that regular measurements permit an accurate determination of the character of progressive wear and further that pulse analysis of MD-10 results can permit a quantitative determination of wear. 4 refs.

  20. Standardised Testing and Assessment in Comprehensive School in Scandinavian Countries

    DEFF Research Database (Denmark)

    Andreasen, Karen Egedal; Eva, Hjörne,

    Assessments can be considered to be an integrated part of formal educational settings, in different forms and used for different purposes. In this contribution we will discuss and analyse the use of assessments in comprehensive school in Scandinavian countries through time, as we will include....... If the comprehensive school is based on the general idea of a school for all, how can different ways of practising assessment support or work against this idea? What conclusions can be drawn from the experiences in the Scandinavian countries?...... different kinds of documentary and empirical studies in the argumentation. We will focus on which kinds of assessments has been used, for which purposes and the role of this in the perspective of society. More contemporary trends will be discussed, specially the use of standardised testing. Scandinavian...

  1. Environmental assessment for double tracks test site, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    1996-04-01

    The U.S. Department of Energy, Nevada Operations Office (DOE/NV), with appropriate approvals from the U.S. Air Force (USAF), proposes to conduct environmental restoration operations at the Double Tracks test site located on the Nellis Air Force Range (NAFR) in Nye County, Nevada. This environmental assessment (EA) evaluates the potential environmental consequences of four alternative actions for conducting the restoration operation and of the no action alternative. The EA also identifies mitigation measures, where appropriate, designed to protect natural and cultural resources and reduce impacts to human health and safety. The environmental restoration operation at the Double Tracks test site would serve two primary objectives. First, the proposed work would evaluate the effectiveness of future restoration operations involving contamination over larger areas. The project would implement remediation technology options and evaluate how these technologies could be applied to the larger areas of contaminated soils on the Nevada Test Site (NTS), the Tonopah Test Range (TTR), and the NAFR. Second, the remediation would provide for the removal of plutonium contamination down to or below a predetermined level which would require cleanup of 1 hectare (ha) (2.5 acres), for the most likely case, or up to 3.0 ha (7.4 acres) of contaminated soil, for the upper bounding case

  2. Integrated testing strategy (ITS) for bioaccumulation assessment under REACH

    DEFF Research Database (Denmark)

    Lombardo, Anna; Roncaglioni, Alessandra; Benfentati, Emilio

    2014-01-01

    in a dossier. REACH promotes the use of alternative methods to replace, refine and reduce the use of animal (eco)toxicity testing. Within the EU OSIRIS project, integrated testing strategies (ITSs) have been developed for the rational use of non-animal testing approaches in chemical hazard assessment. Here we......REACH (registration, evaluation, authorisation and restriction of chemicals) regulation requires that all the chemicals produced or imported in Europe above 1 tonne/year are registered. To register a chemical, physicochemical, toxicological and ecotoxicological information needs to be reported...... present an ITS for evaluating the bioaccumulation potential of organic chemicals. The scheme includes the use of all available data (also the non-optimal ones), waiving schemes, analysis of physicochemical properties related to the end point and alternative methods (both in silico and in vitro). In vivo...

  3. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  4. OSM-Classic : An optical imaging technique for accurately determining strain

    Science.gov (United States)

    Aldrich, Daniel R.; Ayranci, Cagri; Nobes, David S.

    OSM-Classic is a program designed in MATLAB® to provide a method of accurately determining strain in a test sample using an optical imaging technique. Measuring strain for the mechanical characterization of materials is most commonly performed with extensometers, LVDT (linear variable differential transistors), and strain gauges; however, these strain measurement methods suffer from their fragile nature and it is not particularly easy to attach these devices to the material for testing. To alleviate these potential problems, an optical approach that does not require contact with the specimen can be implemented to measure the strain. OSM-Classic is a software that interrogates a series of images to determine elongation in a test sample and hence, strain of the specimen. It was designed to provide a graphical user interface that includes image processing with a dynamic region of interest. Additionally, the stain is calculated directly while providing active feedback during the processing.

  5. Validity, Reliability and Standardization Study of the Language Assessment Test for Aphasia

    Directory of Open Access Journals (Sweden)

    Bülent Toğram

    2012-09-01

    Full Text Available OBJECTIVE: Aphasia assessment is the first step towards a well- founded language therapy. Language tests need to consider cultural as well as typological linguistic aspects of a given language. This study was designed to determine the standardization, validity and reliability of Language Assessment Test for Aphasia, which consists of eight subtests including spontaneous speech and language, auditory comprehension, repetition, naming, reading, grammar, speech acts, and writing. METHODS: The test was administered to 282 healthy participants and 92 aphasic participants in age, education and gender matched groups. The validity study of the test was investigated with analysis of content, structure and criterion-related validity. For reliability of the test, the analysis of internal consistency, stability and equivalence reliability was conducted. The influence of variables on healhty participants’ sub-test scores, test score and language score was examined. According to significant differences, norms and cut-off scores based on language score were determined. RESULTS: The group with aphasia performed highly lower than healthy participants on subtest, test and language scores. The test scores of healthy group were mostly affected by age and educational level but not affected by gender. According to significant differences, age and educational level for both groups were determined. Considering age and educational levels, the reference values for the cut-off scores were presented. CONCLUSION: The test was found to be a highly reliable and valid aphasia test for Turkish- speaking aphasic patients either in Turkey or other Turkish communities around the world

  6. An in vitro human skin test for assessing sensitization potential.

    Science.gov (United States)

    Ahmed, S S; Wang, X N; Fielding, M; Kerry, A; Dickinson, I; Munuswamy, R; Kimber, I; Dickinson, A M

    2016-05-01

    Sensitization to chemicals resulting in an allergy is an important health issue. The current gold-standard method for identification and characterization of skin-sensitizing chemicals was the mouse local lymph node assay (LLNA). However, for a number of reasons there has been an increasing imperative to develop alternative approaches to hazard identification that do not require the use of animals. Here we describe a human in-vitro skin explant test for identification of sensitization hazards and the assessment of relative skin sensitizing potency. This method measures histological damage in human skin as a readout of the immune response induced by the test material. Using this approach we have measured responses to 44 chemicals including skin sensitizers, pre/pro-haptens, respiratory sensitizers, non-sensitizing chemicals (including skin-irritants) and previously misclassified compounds. Based on comparisons with the LLNA, the skin explant test gave 95% specificity, 95% sensitivity, 95% concordance with a correlation coefficient of 0.9. The same specificity and sensitivity were achieved for comparison of results with published human sensitization data with a correlation coefficient of 0.91. The test also successfully identified nickel sulphate as a human skin sensitizer, which was misclassified as negative in the LLNA. In addition, sensitizers and non-sensitizers identified as positive or negative by the skin explant test have induced high/low T cell proliferation and IFNγ production, respectively. Collectively, the data suggests the human in-vitro skin explant test could provide the basis for a novel approach for characterization of the sensitizing activity as a first step in the risk assessment process. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative

    International Nuclear Information System (INIS)

    Bossuyt, P.M.; Reitsma, J.B.; Bruns, D.E.; Gatsonis, C.A.; Glasziou, P.P.; Irwig, L.M.; Lijmer, J.G.; Moher, D.; Rennie, D.; Vet, H.C.W. de

    2003-01-01

    AIM: To improve the accuracy and completeness of reporting of studies of diagnostic accuracy in order to allow readers to assess the potential for bias in a study and to evaluate the general isability of its results. METHODS: The standards for reporting of diagnostic accuracy (STARD) steering committee searched the literature to identify publications on the appropriate conduct and reporting of diagnostic studies and extracted potential items into an extensive list. Researchers, editors, and members of professional organisations shortened this list during a 2 day consensus meeting with the goal of developing a checklist and a generic flow diagram for studies of diagnostic accuracy. RESULTS: The search for published guidelines about diagnostic research yielded 33 previously published checklists, from which we extracted a list of 75 potential items. At the consensus meeting, participants shortened the list to a 25-item checklist, by using evidence whenever available. A prototype of a flow diagram provides information about the method of recruitment of patients, the order of test execution and the numbers of patients undergoing the test under evaluation, the reference standard, or both. CONCLUSIONS: Evaluation of research depends on complete and accurate reporting. If medical journals adopt the checklist and the flow diagram, the quality of reporting of studies of diagnostic accuracy should improve to the advantage of clinicians, researchers, reviewers, journals, and the public

  8. Biomarker assessment and molecular testing for prognostication in breast cancer.

    Science.gov (United States)

    Kos, Zuzana; Dabbs, David J

    2016-01-01

    Current treatment of breast cancer incorporates clinical, pathological and molecular data. Oestrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2) define prognosis and identify tumours for targeted therapy, and remain the sole established single-molecule biomarkers defining the minimum breast cancer pathology data set. Ki67 remains one of the most promising yet controversial biomarkers in breast cancer, implemented routinely in some, but not all, pathology departments. Beyond the single-molecule biomarkers, a host of multigene expression tests have been developed to interrogate the driver pathways and biology of individual breast cancers to predict clinical outcome more accurately. A minority of these assays have entered into clinical practice. This review focuses on the established biomarkers of ER, PR and HER2, the controversial but clinically implemented biomarker Ki67 and the currently marketed gene expression signatures. © 2015 John Wiley & Sons Ltd.

  9. Gulf Coast Programmatic Environmental Assessment Geothermal Well Testing: The Frio Formation of Texas and Louisiana

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-10-01

    In accordance with the requirements of 10 CFR Part 711, environmental assessments are being prepared for significant activities and individual projects of the Division of Geothermal Energy (DGE) of the Energy Research and Development Administration (ERDA). This environmental assessment of geopressure well testing addresses, on a regional basis, the expected activities, affected environments, and possible impacts in a broad sense. The specific part of the program addressed by this environmental assessment is geothermal well testing by the take-over of one or more unsuccessful oil wells before the drilling rig is removed and completion of drilling into the geopressured zone. Along the Texas and Louisiana Gulf Coast (Plate 1 and Overlay) water at high temperatures and high pressures is trapped within Gulf basin sediments. The water is confined within or below essentially impermeable shale sequences and carries most or all of the overburden pressure. Such zones are referred to as geopressured strata. These fluids and sediments are heated to abnormally high temperatures (up to 260 C) and may provide potential reservoirs for economical production of geothermal energy. The obvious need in resource development is to assess the resource. Ongoing studies to define large-sand-volume reservoirs will ultimately define optimum sites for drilling special large diameter wells to perform large volume flow production tests. In the interim, existing well tests need to be made to help define and assess the resource. The project addressed by this environmental assessment is the performance of a geothermal well test in high potential geothermal areas. Well tests involve four major actions each of which may or may not be required for each of the well tests. The four major actions are: site preparation, drilling a salt-water disposal well, actual flow testing, and abandonment of the well.

  10. Assessment of performance of selected serological tests for diagnosing brucellosis in pigs.

    NARCIS (Netherlands)

    Munoz, P.M.; Blasco, J.M.; Engel, B.; Miguel, de M.J.; Marín, C.M.; Dieste, L.; Mainar-Jaime, R.C.

    2012-01-01

    Swine brucellosis due to Brucella suis is considered an emerging zoonotic disease whose control is based on serological testing and the subsequent culling of seropositive animals or the full depopulation of affected flocks. Here we assessed the performance of several serological tests (Rose Bengal

  11. Terrestrial avoidance behaviour tests as screening tool to assess soil contamination

    International Nuclear Information System (INIS)

    Loureiro, Susana; Soares, Amadeu M.V.M.; Nogueira, Antonio J.A.

    2005-01-01

    To assess soil quality and risk assessment, bioassays can be useful tools to gauge the potential toxicity of contaminants focusing on their bioavailable fraction. A rapid and sublethal avoidance behaviour test was used as a screening tool with the earthworm Eisenia andrei and the isopod Porcellionides pruinosus, where organisms were exposed during 48 h to several chemicals (lindane, dimethoate and copper sulphate, for isopods and carbendazim, benomyl, dimethoate and copper sulphate for earthworms). Both species were also exposed to soils from an abandoned mine. For all bioassays a statistical approach was used to derive EC 50 values. Isopods and earthworms were able to perceive the presence of toxic compounds and escaping from contaminated to clean soil. Furthermore the behaviour parameter was equally or more sensitive then other sublethal parameters (e.g. reproduction or growth), expressing the advantages of Avoidance Behaviour Tests as screening tools in ERA. - Avoidance Behaviour Tests with earthworms and isopods can be used as screening tools in the evaluation of soil contamination

  12. Comparison of test specific sediment effect concentrations with marine sediment quality assessment guidelines

    International Nuclear Information System (INIS)

    Carr, R.S.; Biedenbach, J.M.; MacDonald, D.D.

    1995-01-01

    As part of NOAA's National Status and Trends (NS and T) Bioeffects Assessment program and studies conducted by the National Biological Service, numerous sediment quality assessment surveys have recently been conducted along the Atlantic and Gulf coasts of the US using the sea urchin (Arbacia punctulata) fertilization and embryological development tests with pore water. Additional toxicity tests were also conducted in conjunction with most of these studies. The areas that have been sampled include Boston harbor, Massachusetts; Charleston Harbor, Winyah Bay, and Savannah River, South Carolina; St. Simon Sound, Georgia; Biscayne Bay, Tampa Bay, Choctawhatchee Bay, Apalachicola Bay, St. Andrew Bay, and Pensacola Bay, Florida; Galveston Bay, Lavaca Bay, and Sabine Lake, Texas, and 200 stations in the vicinity of offshore oil and gas production platforms in the Gulf of Mexico. Sufficient data are now available from this series of surveys to calculate test specific sediment effect concentrations (SECs). Based on these recent studies, SECs were developed for the sea urchin porewater and amphipod tests and compared with existing marine sediment quality assessment guidelines

  13. Cost benefit and risk assessment for selected tank waste process testing alternatives

    International Nuclear Information System (INIS)

    Gasper, K.A.

    1995-01-01

    The US Department of Energy has established the Tank Waste Remediation System (TWRS) program to safely manage wastes currently stored in underground tank at the Hanford Site. A TWRS testing and development strategy was recently developed to define long-range TWRS testing plans. The testing and development strategy considered four alternatives. The primary variable in the alternatives is the level of pilot-scale testing involving actual waste. This study evaluates the cost benefit and risks associated with the four alternatives. Four types of risk were evaluated: programmatic schedule risk, process mishap risk, worker risk, and public health risk. The structure of this report is as follows: Section 1 introduces the report subject; Section 2 describes the test strategy alternative evaluation; Section 3 describes the approach used in this study to assess risk and cost benefit; Section 4 describes the assessment methodologies for costs and risks; Section 5 describes the bases and assumptions used to estimate the costs and risks; Section 6 presents the detailed costs and risks; and Section 7 describes the results of the cost benefit analysis and presents conclusions

  14. Assessing error sources for Landsat time series analysis for tropical test sites in Viet Nam and Ethiopia

    Science.gov (United States)

    Schultz, Michael; Verbesselt, Jan; Herold, Martin; Avitabile, Valerio

    2013-10-01

    Researchers who use remotely sensed data can spend half of their total effort analysing prior data. If this data preprocessing does not match the application, this time spent on data analysis can increase considerably and can lead to inaccuracies. Despite the existence of a number of methods for pre-processing Landsat time series, each method has shortcomings, particularly for mapping forest changes under varying illumination, data availability and atmospheric conditions. Based on the requirements of mapping forest changes as defined by the United Nations (UN) Reducing Emissions from Forest Degradation and Deforestation (REDD) program, the accurate reporting of the spatio-temporal properties of these changes is necessary. We compared the impact of three fundamentally different radiometric preprocessing techniques Moderate Resolution Atmospheric TRANsmission (MODTRAN), Second Simulation of a Satellite Signal in the Solar Spectrum (6S) and simple Dark Object Subtraction (DOS) on mapping forest changes using Landsat time series data. A modification of Breaks For Additive Season and Trend (BFAST) monitor was used to jointly map the spatial and temporal agreement of forest changes at test sites in Ethiopia and Viet Nam. The suitability of the pre-processing methods for the occurring forest change drivers was assessed using recently captured Ground Truth and high resolution data (1000 points). A method for creating robust generic forest maps used for the sampling design is presented. An assessment of error sources has been performed identifying haze as a major source for time series analysis commission error.

  15. Quality assurance issues in the teacher-based assessment of students with literacy difficulties for examination access arrangements.

    Science.gov (United States)

    McMurray, Sharon; O'Callaghan, Paul; McVeigh, Claire

    2018-02-01

    This paper considers two major concerns centring on the Joint Council for Qualifications (JCQ) regulations for access arrangement and reasonable adjustments and qualifications for teachers who take on the role of Level 7 access arrangements assessor. Thus, the paper is divided into two parts. First, the JCQ 2017-2018 regulations are critically evaluated highlighting the areas of need for which greater clarity and more extensive detail is required in these regulations. The second part of the paper discusses the findings of research on teacher competence in test administration, scoring, and reporting. Drawing on evidence from the first stage of this research, McMurray, O'Callaghan, and McVeigh highlight the extensive formative process required to build a high-level skill set required for competent assessment involving the use of high level tests and also the specialist knowledge required to analyse and accurately report assessment findings to make recommendations for students with specific literacy difficulties. Recommendations are provided both at policy and practice levels regarding the content of courses and the assessment involving the use of high level tests and also the specialist knowledge required to analyse and accurately report assessment findings to make recommendations for students with specific literacy difficulties. The authors provide recommendations for test publishers, course providers, and assessors. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Microbiome Data Accurately Predicts the Postmortem Interval Using Random Forest Regression Models

    Directory of Open Access Journals (Sweden)

    Aeriel Belk

    2018-02-01

    Full Text Available Death investigations often include an effort to establish the postmortem interval (PMI in cases in which the time of death is uncertain. The postmortem interval can lead to the identification of the deceased and the validation of witness statements and suspect alibis. Recent research has demonstrated that microbes provide an accurate clock that starts at death and relies on ecological change in the microbial communities that normally inhabit a body and its surrounding environment. Here, we explore how to build the most robust Random Forest regression models for prediction of PMI by testing models built on different sample types (gravesoil, skin of the torso, skin of the head, gene markers (16S ribosomal RNA (rRNA, 18S rRNA, internal transcribed spacer regions (ITS, and taxonomic levels (sequence variants, species, genus, etc.. We also tested whether particular suites of indicator microbes were informative across different datasets. Generally, results indicate that the most accurate models for predicting PMI were built using gravesoil and skin data using the 16S rRNA genetic marker at the taxonomic level of phyla. Additionally, several phyla consistently contributed highly to model accuracy and may be candidate indicators of PMI.

  17. An immunologic model for rapid vaccine assessment -- a clinical trial in a test tube.

    Science.gov (United States)

    Higbee, Russell G; Byers, Anthony M; Dhir, Vipra; Drake, Donald; Fahlenkamp, Heather G; Gangur, Jyoti; Kachurin, Anatoly; Kachurina, Olga; Leistritz, Del; Ma, Yifan; Mehta, Riyaz; Mishkin, Eric; Moser, Janice; Mosquera, Luis; Nguyen, Mike; Parkhill, Robert; Pawar, Santosh; Poisson, Louis; Sanchez-Schmitz, Guzman; Schanen, Brian; Singh, Inderpal; Song, Haifeng; Tapia, Tenekua; Warren, William; Wittman, Vaughan

    2009-09-01

    While the duration and size of human clinical trials may be difficult to reduce, there are several parameters in pre-clinical vaccine development that may be possible to further optimise. By increasing the accuracy of the models used for pre-clinical vaccine testing, it should be possible to increase the probability that any particular vaccine candidate will be successful in human trials. In addition, an improved model will allow the collection of increasingly more-informative data in pre-clinical tests, thus aiding the rational design and formulation of candidates entered into clinical evaluation. An acceleration and increase in sophistication of pre-clinical vaccine development will thus require the advent of more physiologically-accurate models of the human immune system, coupled with substantial advances in the mechanistic understanding of vaccine efficacy, achieved by using this model. We believe the best viable option available is to use human cells and/or tissues in a functional in vitro model of human physiology. Not only will this more accurately model human diseases, it will also eliminate any ethical, moral and scientific issues involved with use of live humans and animals. An in vitro model, termed "MIMIC" (Modular IMmune In vitro Construct), was designed and developed to reflect the human immune system in a well-based format. The MIMIC System is a laboratory-based methodology that replicates the human immune system response. It is highly automated, and can be used to simulate a clinical trial for a diverse population, without putting human subjects at risk. The MIMIC System uses the circulating immune cells of individual donors to recapitulate each individual human immune response by maintaining the autonomy of the donor. Thus, an in vitro test system has been created that is functionally equivalent to the donor's own immune system and is designed to respond in a similar manner to the in vivo response. 2009 FRAME.

  18. A European perspective on alternatives to animal testing for environmental hazard identification and risk assessment.

    Science.gov (United States)

    Scholz, Stefan; Sela, Erika; Blaha, Ludek; Braunbeck, Thomas; Galay-Burgos, Malyka; García-Franco, Mauricio; Guinea, Joaquin; Klüver, Nils; Schirmer, Kristin; Tanneberger, Katrin; Tobor-Kapłon, Marysia; Witters, Hilda; Belanger, Scott; Benfenati, Emilio; Creton, Stuart; Cronin, Mark T D; Eggen, Rik I L; Embry, Michelle; Ekman, Drew; Gourmelon, Anne; Halder, Marlies; Hardy, Barry; Hartung, Thomas; Hubesch, Bruno; Jungmann, Dirk; Lampi, Mark A; Lee, Lucy; Léonard, Marc; Küster, Eberhard; Lillicrap, Adam; Luckenbach, Till; Murk, Albertinka J; Navas, José M; Peijnenburg, Willie; Repetto, Guillermo; Salinas, Edward; Schüürmann, Gerrit; Spielmann, Horst; Tollefsen, Knut Erik; Walter-Rohde, Susanne; Whale, Graham; Wheeler, James R; Winter, Matthew J

    2013-12-01

    Tests with vertebrates are an integral part of environmental hazard identification and risk assessment of chemicals, plant protection products, pharmaceuticals, biocides, feed additives and effluents. These tests raise ethical and economic concerns and are considered as inappropriate for assessing all of the substances and effluents that require regulatory testing. Hence, there is a strong demand for replacement, reduction and refinement strategies and methods. However, until now alternative approaches have only rarely been used in regulatory settings. This review provides an overview on current regulations of chemicals and the requirements for animal tests in environmental hazard and risk assessment. It aims to highlight the potential areas for alternative approaches in environmental hazard identification and risk assessment. Perspectives and limitations of alternative approaches to animal tests using vertebrates in environmental toxicology, i.e. mainly fish and amphibians, are discussed. Free access to existing (proprietary) animal test data, availability of validated alternative methods and a practical implementation of conceptual approaches such as the Adverse Outcome Pathways and Integrated Testing Strategies were identified as major requirements towards the successful development and implementation of alternative approaches. Although this article focusses on European regulations, its considerations and conclusions are of global relevance. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Accurate mass measurements on neutron-deficient krypton isotopes

    CERN Document Server

    Rodríguez, D.; Äystö, J.; Beck, D.; Blaum, K.; Bollen, G.; Herfurth, F.; Jokinen, A.; Kellerbauer, A.; Kluge, H.-J.; Kolhinen, V.S.; Oinonen, M.; Sauvan, E.; Schwarz, S.

    2006-01-01

    The masses of $^{72–78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72–75}$Kr being more precise than the previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  20. Emergency department assessment of abdominal pain: clinical indicator tests for detecting peritonism.

    Science.gov (United States)

    Taylor, Scott; Watt, Martin

    2005-12-01

    Peritonism is a finding that leads to a more cautious approach in the emergency department management of abdominal pain. This study examined whether peritonism assessment using inspiration, expiration and cough tests was associated with the patient's clinical management. This prospective observational study evaluated consecutive patients presenting directly to the emergency department for 3 months from June 2000 with abdominal pain. Triage initial observations of blood pressure, pulse, respiratory rate, oxygen saturation and temperature were recorded. The examining emergency physician recorded each patient's response and pain score to the individual peritonism tests and scored it as positive if there was an indication of it being a painful manoeuvre. The results were blinded from the receiving specialty if subsequent referral was required. Sixty-seven patients had peritonism tests performed. No individual test was more painful than the others with similar values in pain scores. In all, 70% (7/10) were admitted when all three tests were positive, compared with 21% (12/57) when two or less of the tests scored positive (P=0.004, Fisher's exact test). Admission was not associated with any individual test or combination of tests, or any other variable. The peritonism tests were not associated with any other physiological observation or measurement. These peritonism tests represent a simple investigation, and are significantly associated with admission when all three tests are positive. They seem to be a clinical predictor of cases in which continuing assessment was required, and may be useful as a departmental 'safety net' in the management of abdominal pain.

  1. Higher quality of molecular testing, an unfulfilled priority: Results from external quality assessment for KRAS mutation testing in colorectal cancer.

    Science.gov (United States)

    Tembuyser, Lien; Ligtenberg, Marjolijn J L; Normanno, Nicola; Delen, Sofie; van Krieken, J Han; Dequeker, Elisabeth M C

    2014-05-01

    Precision medicine is now a key element in clinical oncology. RAS mutational status is a crucial predictor of responsiveness to anti-epidermal growth factor receptor agents in metastatic colorectal cancer. In an effort to guarantee high-quality testing services in molecular pathology, the European Society of Pathology has been organizing an annual KRAS external quality assessment program since 2009. In 2012, 10 formalin-fixed, paraffin-embedded samples, of which 8 from invasive metastatic colorectal cancer tissue and 2 artificial samples of cell line material, were sent to more than 100 laboratories from 26 countries with a request for routine KRAS testing. Both genotyping and clinical reports were assessed independently. Twenty-seven percent of the participants genotyped at least 1 of 10 samples incorrectly. In total, less than 5% of the distributed specimens were genotyped incorrectly. Genotyping errors consisted of false negatives, false positives, and incorrectly genotyped mutations. Twenty percent of the laboratories reported a technical error for one or more samples. A review of the written reports showed that several essential elements were missing, most notably a clinical interpretation of the test result, the method sensitivity, and the use of a reference sequence. External quality assessment serves as a valuable educational tool in assessing and improving molecular testing quality and is an important asset for monitoring quality assurance upon incorporation of new biomarkers in diagnostic services. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  2. Assessment of Alcohol-related Memory Deficits: A Comparison between the Rivermead Behavioural Memory Test and the California Verbal Learning Test

    NARCIS (Netherlands)

    Wester, A.J.; Roelofs, R.L.; Egger, J.I.M.; Kessels, R.P.C.

    2014-01-01

    Objectives: Neuropsychological assessment of memory disorders is an important prerequisite in the treatment of patients with alcohol-related cognitive disorders. Although many memory tests are available in clinical practice, a question remains regarding which test is most appropriate for this

  3. Accurate Modeling Method for Cu Interconnect

    Science.gov (United States)

    Yamada, Kenta; Kitahara, Hiroshi; Asai, Yoshihiko; Sakamoto, Hideo; Okada, Norio; Yasuda, Makoto; Oda, Noriaki; Sakurai, Michio; Hiroi, Masayuki; Takewaki, Toshiyuki; Ohnishi, Sadayuki; Iguchi, Manabu; Minda, Hiroyasu; Suzuki, Mieko

    This paper proposes an accurate modeling method of the copper interconnect cross-section in which the width and thickness dependence on layout patterns and density caused by processes (CMP, etching, sputtering, lithography, and so on) are fully, incorporated and universally expressed. In addition, we have developed specific test patterns for the model parameters extraction, and an efficient extraction flow. We have extracted the model parameters for 0.15μm CMOS using this method and confirmed that 10%τpd error normally observed with conventional LPE (Layout Parameters Extraction) was completely dissolved. Moreover, it is verified that the model can be applied to more advanced technologies (90nm, 65nm and 55nm CMOS). Since the interconnect delay variations due to the processes constitute a significant part of what have conventionally been treated as random variations, use of the proposed model could enable one to greatly narrow the guardbands required to guarantee a desired yield, thereby facilitating design closure.

  4. Assessment of Color Vision Among School Children: A Comparative Study Between The Ishihara Test and The Farnsworth D-15 Test

    Directory of Open Access Journals (Sweden)

    Rajesh Kishor Shrestha

    2016-10-01

    Full Text Available Introduction: Color vision is one of the important attribute of visual perception. The study was conducted at different schools of Kathmandu to compare the  ndings of the Ishihara Pseudoisochromatic test and the Farnsworth D-15 test.  Method: A cross-sectional study was conducted among 2120 students of four schools of Kathmandu. Assessment included visual acuity measurement, slit lamp examination of anterior segment and fundus examination with direct ophthalmoscopy. Each student was assessed with the Ishihara pseudoisochromatic test and the Farnsworth D-15 test. The Chi-square test was performed to analyse color vision defect detected by the Ishihara test and the Farnsworth D-15 test. Results: A total of 2120 students comprising of 1114 males (52.5% and 1006 females (47.5% were recruited in the study with mean age of 12.2 years (SD 2.3 years. The prevalence of color vision defect as indicated by the Ishihara was 2.6 and as indicated by the D-15 test was 2.15 in males.  Conclusion: For school color vision screening, the Ishihara color test and the Farnsworth D-15 test have equal capacity to detect congenital color vision defect and they complement each other.  Keywords: color vision; children; defect; Farnsworth D-15; Ishihara.

  5. Test Review: Reynolds, C. R., & Kamphaus, R. W. (2003). "RIAS--Reynolds Intellectual Assessment Scales." Lutz, FL--Psychological Assessment Resources, Inc.

    Science.gov (United States)

    Dombrowski, Stefan C.; Mrazik, Martin

    2008-01-01

    In this article, the authors review the Reynolds Intellectual Assessment Scales (RIAS; Reynolds & Kamphaus, 2003), an individually administered test of intelligence for use with individuals between the ages of 3 and 94. The RIAS represents the newest intelligence test on the marketplace and incorporates the most current intelligence test theory…

  6. Review of intellectual assessment measures for children who are deaf or hard of hearing.

    Science.gov (United States)

    Reesman, Jennifer H; Day, Lori A; Szymanski, Christen A; Hughes-Wheatland, Roxanne; Witkin, Gregory A; Kalback, Shawn R; Brice, Patrick J

    2014-02-01

    Intellectual assessment of children who are deaf or hard of hearing presents unique challenges to the clinician charged with attempting to obtain an accurate representation of the child's skills. Selection of appropriate intellectual assessment instruments requires a working knowledge of the strengths and weaknesses of the measure and what changes in standardized administration might be necessary to accommodate for the needs of children who are deaf or hard of hearing. In the case of some available instruments, there is limited guidance and objective research available examining the performance of children who are deaf or hard of hearing. This review summarizes available information on widely used and most recent editions of intellectual assessment measures with special attention to guidance on accommodations, score interpretation, subtest selection and other test-specific considerations when assessing children who are deaf or hard of hearing. There is much opportunity for further inquiry in the field of intellectual assessment as it applies to children who are deaf or hard of hearing, as many measures have not been closely scrutinized for their appropriate use with this population. Clinicians must recognize inherent difficulties with intellectual assessment measures with children who are deaf or hard of hearing and issues in providing for an accessible and accurate administration of test items. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  7. Testing a Nested Skills Model of the Relations among Invented Spelling, Accurate Spelling, and Word Reading, from Kindergarten to Grade 1

    Science.gov (United States)

    Sénéchal, Monique

    2017-01-01

    The goal was to assess the role of invented spelling to subsequent reading and spelling as proposed by the Nested Skills Model of Early Literacy Acquisition. 107 English-speaking children were tested at the beginning of kindergarten and grade 1, and at the end of grade 1. The findings provided support for the proposed model. First, the role played…

  8. EOS suspension test for the assessment of spinal flexibility in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Hirsch, Caroline; Ilharreborde, Brice; Mazda, Keyvan

    2015-07-01

    The assessment of spinal flexibility is essential for the planning of adolescent idiopathic scoliosis (AIS) surgery. Various radiographic methods have been used but none of them has shown any superiority. The new low-dose stereography system EOS (EOS imaging, Paris, France) captures whole body images in a single scan without vertical distortion. EOS is now used in routine clinical use for AIS follow-up. The aim of this study was to prospectively evaluate the feasibility and the reproducibility of a new suspension test during the EOS imaging for the assessment of spinal flexibility in AIS. Fifty AIS patients scheduled for surgery were prospectively included. For each patient, a standard EOS radiograph was obtained, then a suspension test in the EOS and a classic traction test on the cotrel frame were performed. The examinations were compared in terms of radiation exposure, tolerance, mean traction force, and Cobb angle reduction for each curve. Axial and sagittal reductions during suspension were analyzed on three-dimensional EOS reconstructions. The tolerance of the suspension test was lower than the traction test but it was less operator dependent. Radiation exposure was 7 times lower during the suspension test. Cobb angle reductions achieved in the proximal and main curves by the two tests were similar. The traction test achieved greater reduction of the distal curve. Flexibility in the axial plane and in the sagittal plane was analyzed with the suspension test. The reduction in apical rotation was not correlated with the reduction in Cobb angle. The EOS suspension test can be used for the assessment of spinal flexibility in AIS. It gives a global vision of the deformity with new flexibility indices in the axial and sagittal planes.

  9. Monitoring nutritional status accurately and reliably in adolescents with anorexia nervosa.

    Science.gov (United States)

    Martin, Andrew C; Pascoe, Elaine M; Forbes, David A

    2009-01-01

    Accurate assessment of nutritional status is a vital aspect of caring for individuals with anorexia nervosa (AN) and body mass index (BMI) is considered an appropriate and easy to use tool. Because of the intense fear of weight gain, some individuals may attempt to mislead the physician. Mid-upper arm circumference (MUAC) is a simple, objective method of assessing nutritional status. The setting is an eating disorders clinic in a tertiary paediatric hospital in Western Australia. The aim of this study is to evaluate how well MUAC correlates with BMI in adolescents with AN. Prospective observational study to evaluate nutritional status in adolescents with AN. Fifty-five adolescents aged 12-17 years with AN were assessed between January 1, 2004 and January 1, 2006. MUAC was highly correlated with BMI (r = 0.79, P or=20 cm rarely required hospitalisation (negative predictive value 93%). MUAC reflects nutritional status as defined by BMI in adolescents with AN. Lack of consistency between longitudinal measurements of BMI and MUAC should be viewed suspiciously and prompt a more detailed nutritional assessment.

  10. Control room habitability assessment and in-leakage test for Korean NPP - 15510

    International Nuclear Information System (INIS)

    Song, D.S.; Lee, J.B.; Ha, S.J.; Seong, J.J.

    2015-01-01

    The assessment of control room habitability for Wolsung unit 1 was performed based on GL 2003-01 and Reg. Guide 1.197. The control room habitability program including Control Room Envelope (CRE) in-leakage test procedures, self assessment guidance, CRE boundary control program, CRE maintenance/sealing program was developed for Wolsung unit 1. The integrated CRE test was performed utilizing ASTM E741. There are two operating modes of pressurization and isolation for CRE ventilation test, and four tests were performed using each of the control room HVAC sub-trains. The control room HVAC system lineup of pressurization mode test was based upon a lineup that encompassed the design basis radiological analyses. The other control room HVAC system lineup of isolation mode test was based on an operation mode that considers toxic gas. The in-leakage testing was performed in accordance with CRE in-leakage test procedures. In the pressurization mode, measured unfiltered in-leakage rates for train A and train B were 0 CFM and 405 CFM respectively. In the isolation mode, measured unfiltered in-leakage rates for train A and train B were 1,739 CFM and 1,502 CFM, respectively. Maximum concentration of ammonia at the control room HVAC intake is calculated to be 0.027 g/m 3 (39 ppm), and satisfied the toxicity limit of 300 ppm. The test result shows that the measured unfiltered in-leakage is bounded by the regulatory criteria assumed in the design basis radiological analyses. (authors)

  11. Accurate RNA consensus sequencing for high-fidelity detection of transcriptional mutagenesis-induced epimutations.

    Science.gov (United States)

    Reid-Bayliss, Kate S; Loeb, Lawrence A

    2017-08-29

    Transcriptional mutagenesis (TM) due to misincorporation during RNA transcription can result in mutant RNAs, or epimutations, that generate proteins with altered properties. TM has long been hypothesized to play a role in aging, cancer, and viral and bacterial evolution. However, inadequate methodologies have limited progress in elucidating a causal association. We present a high-throughput, highly accurate RNA sequencing method to measure epimutations with single-molecule sensitivity. Accurate RNA consensus sequencing (ARC-seq) uniquely combines RNA barcoding and generation of multiple cDNA copies per RNA molecule to eliminate errors introduced during cDNA synthesis, PCR, and sequencing. The stringency of ARC-seq can be scaled to accommodate the quality of input RNAs. We apply ARC-seq to directly assess transcriptome-wide epimutations resulting from RNA polymerase mutants and oxidative stress.

  12. A portable generic elementary function package in Ada and an accurate test suite

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Ping Tak Peter.

    1990-11-01

    A comprehensive set of elementary functions has been implemented portably in Ada. The high accuracy of the implementation has been confirmed by rigorous analysis. Moreover, we present new test methods that are efficient and offer a high resolution of 0.005 unit in the last place. These test methods have been implemented portably here and confirm the accuracy of our implemented functions. Reports on the accuracy of other function libraries obtained by our test programs are also presented. 26 refs., 9 tabs.

  13. Fatigue Assessment of High Strength Steel Welded Joints Under Bending Loading

    International Nuclear Information System (INIS)

    Lee, Myeong-Woo; Kim, Yun-Jae; Park, Jun-Hyub

    2014-01-01

    In this study, a fatigue assessment method for vehicle suspension systems having welded geometries was established under a bending loading condition. For the fatigue life estimation of the actual product s welded joints made of different steels, bending fatigue tests were performed on welded specimens with a simplified shape for obtaining the moment-fatigue-life plot. Further, geometry modeling of the simplified welded specimens was conducted. Results of finite element analysis were used to obtain the stress-fatigue-life plot. The analysis results were also used to calculate the stress concentration factors for notch-factor-based fatigue life estimation. The test results were compared with results of the general notch-factor-based fatigue life estimation for improving fatigue assessment. As a result, it was concluded that both the welded fatigue tests and the notch-factor-based fatigue life estimation are necessary for accurate fatigue assessment

  14. Self-Assessment, Preparation and Response Time on a Computerized Oral Proficiency Test

    Science.gov (United States)

    Malabonga, Valerie; Kenyon, Dorry M.; Carpenter, Helen

    2005-01-01

    Two studies investigated technical aspects of a computer-mediated test, the Computerized Oral Proficiency Instrument (COPI), particularly in contrast to a similar tape-mediated test, the Simulated Oral Proficiency Interview (SOPI). The first study investigated how examinees used self-assessment to choose an appropriate starting level on the COPI.…

  15. Simple, fast and accurate two-diode model for photovoltaic modules

    Energy Technology Data Exchange (ETDEWEB)

    Ishaque, Kashif; Salam, Zainal; Taheri, Hamed [Faculty of Electrical Engineering, Universiti Teknologi Malaysia, UTM 81310, Skudai, Johor Bahru (Malaysia)

    2011-02-15

    This paper proposes an improved modeling approach for the two-diode model of photovoltaic (PV) module. The main contribution of this work is the simplification of the current equation, in which only four parameters are required, compared to six or more in the previously developed two-diode models. Furthermore the values of the series and parallel resistances are computed using a simple and fast iterative method. To validate the accuracy of the proposed model, six PV modules of different types (multi-crystalline, mono-crystalline and thin-film) from various manufacturers are tested. The performance of the model is evaluated against the popular single diode models. It is found that the proposed model is superior when subjected to irradiance and temperature variations. In particular the model matches very accurately for all important points of the I-V curves, i.e. the peak power, short-circuit current and open circuit voltage. The modeling method is useful for PV power converter designers and circuit simulator developers who require simple, fast yet accurate model for the PV module. (author)

  16. Prediction of clinical response to drugs in ovarian cancer using the chemotherapy resistance test (CTR-test).

    Science.gov (United States)

    Kischkel, Frank Christian; Meyer, Carina; Eich, Julia; Nassir, Mani; Mentze, Monika; Braicu, Ioana; Kopp-Schneider, Annette; Sehouli, Jalid

    2017-10-27

    In order to validate if the test result of the Chemotherapy Resistance Test (CTR-Test) is able to predict the resistances or sensitivities of tumors in ovarian cancer patients to drugs, the CTR-Test result and the corresponding clinical response of individual patients were correlated retrospectively. Results were compared to previous recorded correlations. The CTR-Test was performed on tumor samples from 52 ovarian cancer patients for specific chemotherapeutic drugs. Patients were treated with monotherapies or drug combinations. Resistances were classified as extreme (ER), medium (MR) or slight (SR) resistance in the CTR-Test. Combination treatment resistances were transformed by a scoring system into these classifications. Accurate sensitivity prediction was accomplished in 79% of the cases and accurate prediction of resistance in 100% of the cases in the total data set. The data set of single agent treatment and drug combination treatment were analyzed individually. Single agent treatment lead to an accurate sensitivity in 44% of the cases and the drug combination to 95% accuracy. The detection of resistances was in both cases to 100% correct. ROC curve analysis indicates that the CTR-Test result correlates with the clinical response, at least for the combination chemotherapy. Those values are similar or better than the values from a publication from 1990. Chemotherapy resistance testing in vitro via the CTR-Test is able to accurately detect resistances in ovarian cancer patients. These numbers confirm and even exceed results published in 1990. Better sensitivity detection might be caused by a higher percentage of drug combinations tested in 2012 compared to 1990. Our study confirms the functionality of the CTR-Test to plan an efficient chemotherapeutic treatment for ovarian cancer patients.

  17. Simulation testing the robustness of stock assessment models to error: some results from the ICES strategic initiative on stock assessment methods

    DEFF Research Database (Denmark)

    Deroba, J. J.; Butterworth, D. S.; Methot, R. D.

    2015-01-01

    The World Conference on Stock Assessment Methods (July 2013) included a workshop on testing assessment methods through simulations. The exercise was made up of two steps applied to datasets from 14 representative fish stocks from around the world. Step 1 involved applying stock assessments to dat...

  18. Accurate characterization of OPVs: Device masking and different solar simulators

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Carlé, Jon Eggert; Søndergaard, Roar R.

    2013-01-01

    One of the prime objects of organic solar cell research has been to improve the power conversion efficiency. Unfortunately, the accurate determination of this property is not straight forward and has led to the recommendation that record devices be tested and certified at a few accredited...... laboratories following rigorous ASTM and IEC standards. This work tries to address some of the issues confronting the standard laboratory in this regard. Solar simulator lamps are investigated for their light field homogeneity and direct versus diffuse components, as well as the correct device area...

  19. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning.

    Science.gov (United States)

    Silva, Susana F; Domingues, José Paulo; Morgado, António Miguel

    2018-01-01

    Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.

  20. Testing of Small Graphite Samples for Nuclear Qualification

    Energy Technology Data Exchange (ETDEWEB)

    Julie Chapman

    2010-11-01

    Accurately determining the mechanical properties of small irradiated samples is crucial to predicting the behavior of the overal irradiated graphite components within a Very High Temperature Reactor. The sample size allowed in a material test reactor, however, is limited, and this poses some difficulties with respect to mechanical testing. In the case of graphite with a larger grain size, a small sample may exhibit characteristics not representative of the bulk material, leading to inaccuracies in the data. A study to determine a potential size effect on the tensile strength was pursued under the Next Generation Nuclear Plant program. It focuses first on optimizing the tensile testing procedure identified in the American Society for Testing and Materials (ASTM) Standard C 781-08. Once the testing procedure was verified, a size effect was assessed by gradually reducing the diameter of the specimens. By monitoring the material response, a size effect was successfully identified.

  1. SELF-ASSESSMENT, QUESTIONNAIRES AND MEMORY TESTS IN A SIMULATED DRIVING TASK

    OpenAIRE

    Combe-Pangaud , Chantal; Jacquet-Andrieu , Armelle

    2009-01-01

    disponible sur : http://www.chalmers.se/safer/driverdistraction-en; International audience; This paper concerns the results of a memorizing test (visual recognition and hearing recall) during an experiment of simulated driving in a magneto-encephalographic environment. The memory tests (questionnaires) are adapted to the measurement of subjective self-assessment: "tiredness" and "facility" perceptions, corralled to simple (ST) and double task (ST/DT: hearing a radio broadcast). Each subject h...

  2. Using slides to test for changes in crown defoliation assessment methods. Part I: Visual assessment of slides.

    Science.gov (United States)

    Dobbertin, Matthias; Hug, Christian; Mizoue, Nobuya

    2004-11-01

    In this study we used photographs of tree crowns to test whether the assessment methods for tree defoliation in Switzerland have changed over time. We randomly selected 24 series of slides of Norway spruce with field assessments made between 1986 and 1995. The slides were randomly arranged and assessed by three experts without prior knowledge of the year when the slide was taken or the tree number. Defoliation was assessed using the Swiss reference photo guide. Although the correlations between the field assessments and slide assessments were high (Spearman's rank correlation coefficient ranged between 0.79 and 0.83), we found significant differences between field and slide assessments (4.3 to 9% underprediction by the slide assessors) and between the slide assessments. However, no significant trends in field assessment methods could be detected. When the mean differences between field and slide assessments were subtracted, in some years, field assessors consistently underpredicted (1990, 1992) or overpredicted defoliation (1987, 1991). Defoliation tended to be overpredicted in slides taken against the light, and underpredicted for trees with more than 25% crown overlap. We conclude that slide series can be used to detect changes in assessment methods. However, potential observer bias calls for more objective methods of assessment.

  3. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session. PMID:24324421

  4. The Harvard Beat Assessment Test (H-BAT): a battery for assessing beat perception and production and their dissociation.

    Science.gov (United States)

    Fujii, Shinya; Schlaug, Gottfried

    2013-01-01

    Humans have the abilities to perceive, produce, and synchronize with a musical beat, yet there are widespread individual differences. To investigate these abilities and to determine if a dissociation between beat perception and production exists, we developed the Harvard Beat Assessment Test (H-BAT), a new battery that assesses beat perception and production abilities. H-BAT consists of four subtests: (1) music tapping test (MTT), (2) beat saliency test (BST), (3) beat interval test (BIT), and (4) beat finding and interval test (BFIT). MTT measures the degree of tapping synchronization with the beat of music, whereas BST, BIT, and BFIT measure perception and production thresholds via psychophysical adaptive stair-case methods. We administered the H-BAT on thirty individuals and investigated the performance distribution across these individuals in each subtest. There was a wide distribution in individual abilities to tap in synchrony with the beat of music during the MTT. The degree of synchronization consistency was negatively correlated with thresholds in the BST, BIT, and BFIT: a lower degree of synchronization was associated with higher perception and production thresholds. H-BAT can be a useful tool in determining an individual's ability to perceive and produce a beat within a single session.

  5. Distributed Pedestrian Detection Alerts Based on Data Fusion with Accurate Localization

    Directory of Open Access Journals (Sweden)

    Arturo de la Escalera

    2013-09-01

    Full Text Available Among Advanced Driver Assistance Systems (ADAS pedestrian detection is a common issue due to the vulnerability of pedestrians in the event of accidents. In the present work, a novel approach for pedestrian detection based on data fusion is presented. Data fusion helps to overcome the limitations inherent to each detection system (computer vision and laser scanner and provides accurate and trustable tracking of any pedestrian movement. The application is complemented by an efficient communication protocol, able to alert vehicles in the surroundings by a fast and reliable communication. The combination of a powerful location, based on a GPS with inertial measurement, and accurate obstacle localization based on data fusion has allowed locating the detected pedestrians with high accuracy. Tests proved the viability of the detection system and the efficiency of the communication, even at long distances. By the use of the alert communication, dangerous situations such as occlusions or misdetections can be avoided.

  6. Distributed pedestrian detection alerts based on data fusion with accurate localization.

    Science.gov (United States)

    García, Fernando; Jiménez, Felipe; Anaya, José Javier; Armingol, José María; Naranjo, José Eugenio; de la Escalera, Arturo

    2013-09-04

    Among Advanced Driver Assistance Systems (ADAS) pedestrian detection is a common issue due to the vulnerability of pedestrians in the event of accidents. In the present work, a novel approach for pedestrian detection based on data fusion is presented. Data fusion helps to overcome the limitations inherent to each detection system (computer vision and laser scanner) and provides accurate and trustable tracking of any pedestrian movement. The application is complemented by an efficient communication protocol, able to alert vehicles in the surroundings by a fast and reliable communication. The combination of a powerful location, based on a GPS with inertial measurement, and accurate obstacle localization based on data fusion has allowed locating the detected pedestrians with high accuracy. Tests proved the viability of the detection system and the efficiency of the communication, even at long distances. By the use of the alert communication, dangerous situations such as occlusions or misdetections can be avoided.

  7. Comparison of cough reflex test against instrumental assessment of aspiration.

    Science.gov (United States)

    Miles, Anna; Moore, Sara; McFarlane, Mary; Lee, Fiona; Allen, Jacqueline; Huckabee, Maggie-Lee

    2013-06-13

    Silent aspiration is associated with pneumonia and mortality, and is poorly identified by traditional clinical swallowing evaluation (CSE). The aim of this study was to validate cough reflex testing (CRT) for identification of silent aspiration against aspiration confirmed by instrumental assessment. Cough reflex threshold testing was completed on all patients using inhaled, nebulised citric acid. Within an hour, 80 patients underwent videofluoroscopic study of swallowing (VFSS) and 101 patients underwent fibreoptic endoscopic evaluation of swallowing (FEES). All tests were recorded and analysed by two researchers blinded to the result of the alternate test. Significant associations between CRT result and cough response to aspiration on VFSS (X(2) (2)=11.046, p=.003) and FEES (X(2) (2)=34.079, pacid provide a better predictive measure of silent aspiration. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. FORENSIC TESTS IN SPANISH FOR ASSESSING JUVENILE OFFENDERS

    Directory of Open Access Journals (Sweden)

    Lorena Wenger

    2016-05-01

    Full Text Available Objectively and rigorously understanding the individual psychological characteristics of adolescent offenders, such as intelligence, personality traits and others of a clinical and criminological nature, is essential when developing appropriate processes for intervention in educational and judicial measures in the context of juvenile justice. However, the clinical and personological tools described in the previous article (Wenger & Andrés-Pueyo, 2016 are not enough to address the criminogenic needs of the adolescents and other, more specific, tools are needed. In this article, a number of complementary instruments developed specifically for the forensic area are reviewed. These tools enable us to carry out very specific assessments in this context, such as the evaluation of the risk of violence or the assessment of psychopathy. A review is also presented of the forensic psychological tests available in Spanish for professionals in the field of juvenile justice.

  9. Testing of Method for Assessing of Room Thermal Stability

    Directory of Open Access Journals (Sweden)

    Charvátová Hana

    2017-01-01

    Full Text Available The paper presents the interim results of our research on the developing methodological procedure which could be used for assessment of a thermal stability of buildings with regards to its thermal accumulative parameters. The principle of testing is based on a combination of computer simulation of cooled room model developed in COMSOL Multiphysics software and on theoretical calculations with respect to compliance with valid European and Czech technical standards used in building industry and architecture under conditions obtained by real measurement for the room to be tested. The presented example shows the effect of the heataccumulation properties of the outside wall insulation materials on the course of the cooling room for winter conditions.

  10. Environmental risk assessment and management of engineered nanomaterials - The role of ecotoxicity testing

    DEFF Research Database (Denmark)

    Hjorth, Rune

    replaced with a focus on in silico and in vitro studies with an even greater need for and reliance on extrapolation. However, in this thesis it is argued that within ecotoxicity, whole organism models remain at the foundation of environmental risk assessment, and as such, they are likely to remain in use...... will be available, it is important that tools encompassing uncertainty are utilized to facilitate decision-support. As the risk constituted by ENMs cannot be quantified, the use, need and ability of risk management options to encompass the potential risk are similarly challenged. This should invoke a precautionary...... to these is the continued examination of the applicability of ecotoxicity testing to encompass the testing of particles, as the tests originally are developed for dissolved chemicals. Furthermore, the ability of such testing to inform environmental risk assessment and environmental risk management, including...

  11. Accurate and Precise Titriraetric Analysis of Uranium in Nuclear Fuels. RCN Report

    International Nuclear Information System (INIS)

    Tolk, A.; Lingerak, W.A.; Verheul-Klompmaker, T.A.

    1970-09-01

    For the accurate and precise titrimetric analysis of uranium in nuclear fuels, the material is dissolved in orthophosphoric and nitric acids. The nitric acid is fumed off, and the U (VI) present is analysed reductometrically in a CO 2 -atmosphere with iron (II) ammonium sulfate. For U 3 O 8 -test-sample aliquots of resp. 800 and 80 mg coefficients of variation of 0.012 resp. 0.11% are measured. (author)

  12. Accurate assessment of long-term nephrotoxicity after peptide receptor radionuclide therapy with {sup 177}Lu-octreotate

    Energy Technology Data Exchange (ETDEWEB)

    Sabet, Amir; Ezziddin, Khaled; Reichman, Karl; Haslerud, Torjan; Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen; Ezziddin, Samer [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Pape, Ulrich-Frank [Charite, University Medicine Berlin, Campus Virchow Clinic, Department of Hepatology and Gastroenterology, Berlin (Germany); Nagarajah, James [University Hospital, Department of Nuclear Medicine, Essen (Germany)

    2014-03-15

    Renal radiation during peptide receptor radionuclide therapy (PRRT) may result in glomerular damage, a potential reduction of glomerular filtration rate (GFR) and ultimately lead to renal failure. While reported PRRT nephrotoxicity is limited to data derived from serum creatinine - allowing only approximate estimates of GFR - the aim of this study is to accurately determine PRRT-induced long-term changes of renal function and associated risk factors according to state-of-the-art GFR measurement. Nephrotoxicity was analysed using {sup 99m}Tc-diethylenetriaminepentaacetic acid (DTPA) clearance data of 74 consecutive patients with gastroenteropancreatic neuroendocrine tumours (GEP NET) undergoing PRRT with {sup 177}Lu-octreotate. The mean follow-up period was 21 months (range 12-50) with a median of five GFR measurements per patient. The change of GFR was analysed by linear curve fit. Potential risk factors including diabetes mellitus, arterial hypertension, previous chemotherapy, renal impairment at baseline and cumulative administered activity were analysed regarding potential impact on renal function loss. In addition, Common Terminology Criteria for Adverse Events (CTCAE) v3.0 were used to compare nephrotoxicity determined by {sup 99m}Tc-DTPA clearance versus serum creatinine. The alteration in GFR differed widely among the patients (mean -2.1 ± 13.1 ml/min/m{sup 2} per year, relative yearly reduction -1.8 ± 18.9 %). Fifteen patients (21 %) experienced a mild (2-10 ml/min/m{sup 2} per year) and 16 patients (22 %) a significant (>10 ml/min/m{sup 2} per year) decline of GFR following PRRT. However, 11 patients (15 %) showed an increase of >10 ml/min/m{sup 2} per year. Relevant nephrotoxicity according to CTCAE (grade ≥3) was observed in one patient (1.3 %) with arterial hypertension and history of chemotherapy. Nephrotoxicity according to serum creatinine was discordant to that defined by GFR in 15 % of the assessments and led to underestimation in 12 % of

  13. Physiological assessment of sensitivity of noninvasive testing for coronary artery disease

    International Nuclear Information System (INIS)

    Simonetti, I.; Rezai, K.; Rossen, J.D.; Winniford, M.D.; Talman, C.L.; Hollenberg, M.; Kirchner, P.T.; Marcus, M.L.

    1991-01-01

    The sensitivity of three noninvasive tests for coronary artery disease was assessed by means of quantitative indexes of disease severity in three different groups of patients. The overall population consisted of 110 subjects with limited coronary artery disease and no myocardial infarction. Planar dipyridamole- 201 Tl scintigraphy was evaluated in 31 patients, computer-assisted exercise treadmill in 28, and high-dose dipyridamole echocardiography testing in 51. Sensitivity was assessed by rigorous gold standards to define disease severity, such as measurement of minimum cross-sectional area and percent area of stenosis, by quantitative computerized coronary angiography (Brown/Dodge method). On the basis of the results of previous studies, the presence of physiologically significant coronary artery disease was indicated by a stenotic minimum cross-sectional area (MCSA) of less than 2.0 mm 2 or a greater than 75% area of stenosis. With MCSA as the gold standard, dipyridamole- 201 Tl scintigraphy, computerized exercise treadmill, and dipyridamole echocardiography testing showed sensitivities of 52%, 54%, and 61%, respectively, in the three different patient cohorts enrolled. With percent area of stenosis as the gold standard, the sensitivity figures obtained for dipyridamole- 201 Tl, computerized exercise treadmill, and dipyridamole echocardiography testing were 64%, 54%, and 69%, respectively. For each of the three tests, sensitivity increased with increasing lesion severity. Sensitivity was also better in patients with left anterior descending coronary (LAD) disease when compared with patients with left circumflex or right coronary artery disease. Results of these studies demonstrate that in patients with limited coronary artery disease none of the tests evaluated is definitely superior in sensitivity

  14. Assessment of Nondeclarative Learning in Severe Alzheimer Dementia The Implicit Memory Test (IMT)

    NARCIS (Netherlands)

    Kessels, R.P.C.; Remmerswaal, M.; Wilson, B.A.

    2011-01-01

    Although patients with Alzheimer dementia (AD) have impaired explicit memory, more automatic, implicit aspects of learning and memory may be relatively preserved. However, neuropsychological tests for the assessment of implicit memory are lacking. This study examines a newly developed test, the

  15. Assessment of nondeclarative learning in severe Alzheimer dementia: the Implicit Memory Test (IMT)

    NARCIS (Netherlands)

    Kessels, R.P.C.; Remmerswaal, M.; Wilson, B.A.

    2011-01-01

    Although patients with Alzheimer dementia (AD) have impaired explicit memory, more automatic, implicit aspects of learning and memory may be relatively preserved. However, neuropsychological tests for the assessment of implicit memory are lacking. This study examines a newly developed test, the

  16. Commutability of food microbiology proficiency testing samples.

    Science.gov (United States)

    Abdelmassih, M; Polet, M; Goffaux, M-J; Planchon, V; Dierick, K; Mahillon, J

    2014-03-01

    Food microbiology proficiency testing (PT) is a useful tool to assess the analytical performances among laboratories. PT items should be close to routine samples to accurately evaluate the acceptability of the methods. However, most PT providers distribute exclusively artificial samples such as reference materials or irradiated foods. This raises the issue of the suitability of these samples because the equivalence-or 'commutability'-between results obtained on artificial vs. authentic food samples has not been demonstrated. In the clinical field, the use of noncommutable PT samples has led to erroneous evaluation of the performances when different analytical methods were used. This study aimed to provide a first assessment of the commutability of samples distributed in food microbiology PT. REQUASUD and IPH organized 13 food microbiology PTs including 10-28 participants. Three types of PT items were used: genuine food samples, sterile food samples and reference materials. The commutability of the artificial samples (reference material or sterile samples) was assessed by plotting the distribution of the results on natural and artificial PT samples. This comparison highlighted matrix-correlated issues when nonfood matrices, such as reference materials, were used. Artificially inoculated food samples, on the other hand, raised only isolated commutability issues. In the organization of a PT-scheme, authentic or artificially inoculated food samples are necessary to accurately evaluate the analytical performances. Reference materials, used as PT items because of their convenience, may present commutability issues leading to inaccurate penalizing conclusions for methods that would have provided accurate results on food samples. For the first time, the commutability of food microbiology PT samples was investigated. The nature of the samples provided by the organizer turned out to be an important factor because matrix effects can impact on the analytical results. © 2013

  17. Testing of the McMath-Pierce 0.8-Meter East Auxiliary Telescope's Acquisition and Slewing Accuracy

    Science.gov (United States)

    Harshaw, Richard; Ray, Jimmy; Prause, Lori; Douglass, David; Branston, Detrick; Genet, Russell M.

    2015-09-01

    Following mediocre results with pointing tests of the McMath-Pierce 0.8-meter East Auxiliary Telescope in April 2014, a team of astronomers/engineers met again in May 2014 to test other pointing models and assess the telescope's ability to point with enough accuracy to permit the efficient use of speckle interferometry. Results show that accurate collimation is a pre-requisite for such accuracy. Once attained, the telescope performs extremely well.

  18. Reliability of core test – Critical assessment and proposed new approach

    OpenAIRE

    Shafik Khoury; Ali Abdel-Hakam Aliabdo; Ahmed Ghazy

    2014-01-01

    Core test is commonly required in the area of concrete industry to evaluate the concrete strength and sometimes it becomes the unique tool for safety assessment of existing concrete structures. Core test is therefore introduced in most codes. An extensive literature survey on different international codes’ provisions; including the Egyptian, British, European and ACI Codes, for core analysis is presented. All studied codes’ provisions seem to be unreliable for predicting the in-situ concrete ...

  19. Accurate particle speed prediction by improved particle speed measurement and 3-dimensional particle size and shape characterization technique

    DEFF Research Database (Denmark)

    Cernuschi, Federico; Rothleitner, Christian; Clausen, Sønnik

    2017-01-01

    Accurate particle mass and velocity measurement is needed for interpreting test results in erosion tests of materials and coatings. The impact and damage of a surface is influenced by the kinetic energy of a particle, i.e. particle mass and velocity. Particle mass is usually determined with optic...

  20. Explanatory item response modelling of an abstract reasoning assessment: A case for modern test design

    OpenAIRE

    Helland, Fredrik

    2016-01-01

    Assessment is an integral part of society and education, and for this reason it is important to know what you measure. This thesis is about explanatory item response modelling of an abstract reasoning assessment, with the objective to create a modern test design framework for automatic generation of valid and precalibrated items of abstract reasoning. Modern test design aims to strengthen the connections between the different components of a test, with a stress on strong theory, systematic it...

  1. Independent assessment of TRAC and RELAP5 codes through separate effects tests

    International Nuclear Information System (INIS)

    Saha, P.; Rohatgi, U.S.; Jo, J.H.; Neymotin, L.; Slovik, G.; Yuelys-Miksis, C.; Pu, J.

    1983-01-01

    Independent assessment of TRAC-PF1 (Version 7.0), TRAC-BD1 (Version 12.0) and RELAP5/MOD1 (Cycle 14) that was initiated at BNL in FY 1982, has been completed in FY 1983. As in the previous years, emphasis at Brookhaven has been in simulating various separate-effects tests with these advanced codes and identifying the areas where further thermal-hydraulic modeling improvements are needed. The following six catetories of tests were simulated with the above codes: (1) critical flow tests (Moby-Dick nitrogen-water, BNL flashing flow, Marviken Test 24); (2) Counter-Current Flow Limiting (CCFL) tests (University of Houston, Dartmouth College single and parallel tube test); (3) level swell tests (G.E. large vessel test); (4) steam generator tests (B and W 19-tube model S.G. tests, FLECHT-SEASET U-tube S.G. tests); (5) natural circulation tests (FRIGG loop tests); and (6) post-CHF tests (Oak Ridge steady-state test)

  2. Reliability assessment for safety critical systems by statistical random testing

    International Nuclear Information System (INIS)

    Mills, S.E.

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs

  3. Reliability assessment for safety critical systems by statistical random testing

    Energy Technology Data Exchange (ETDEWEB)

    Mills, S E [Carleton Univ., Ottawa, ON (Canada). Statistical Consulting Centre

    1995-11-01

    In this report we present an overview of reliability assessment for software and focus on some basic aspects of assessing reliability for safety critical systems by statistical random testing. We also discuss possible deviations from some essential assumptions on which the general methodology is based. These deviations appear quite likely in practical applications. We present and discuss possible remedies and adjustments and then undertake applying this methodology to a portion of the SDS1 software. We also indicate shortcomings of the methodology and possible avenues to address to follow to address these problems. (author). 128 refs., 11 tabs., 31 figs.

  4. Model testing for the remediation assessment of a radium contaminated site in Olen, Belgium

    International Nuclear Information System (INIS)

    Sweeck, Lieve; Kanyar, Bela; Krajewski, Pawel; Kryshev, Alexander; Lietava, Peter; Nenyei, Arpad; Sazykina, Tatiana; Yu, Charley; Zeevaert, Theo

    2005-01-01

    Environmental assessment models are used as decision-aiding tools in the selection of remediation options for radioactively contaminated sites. In most cases, the effectiveness of the remedial actions in terms of dose savings cannot be demonstrated directly, but can be established with the help of environmental assessment models, through the assessment of future radiological impacts. It should be emphasized that, given the complexity of the processes involved and our current understanding of how they operate, these models are simplified descriptions of the behaviour of radionuclides in the environment and therefore imperfect. One way of testing and improving the reliability of the models is to compare their predictions with real data and/or the predictions of other models. Within the framework of the Remediation Assessment Working Group (RAWG) of the BIOMASS (BIOsphere Modelling and ASSessment) programme coordinated by IAEA, two scenarios were constructed and applied to test the reliability of environmental assessment models when remedial actions are involved. As a test site, an area of approximately 100 ha contaminated by the discharges of an old radium extraction plant in Olen (Belgium) has been considered. In the first scenario, a real situation was evaluated and model predictions were compared with measured data. In the second scenario the model predictions for specific hypothetical but realistic situations were compared. Most of the biosphere models were not developed to assess the performance of remedial actions and had to be modified for this purpose. It was demonstrated clearly that the modeller's experience and familiarity with the mathematical model, the site and with the scenario play a very important role in the outcome of the model calculations. More model testing studies, preferably for real situations, are needed in order to improve the models and modelling methods and to expand the areas in which the models are applicable

  5. Computer-based personality judgments are more accurate than those made by humans.

    Science.gov (United States)

    Youyou, Wu; Kosinski, Michal; Stillwell, David

    2015-01-27

    Judging others' personalities is an essential skill in successful social living, as personality is a key driver behind people's interactions, behaviors, and emotions. Although accurate personality judgments stem from social-cognitive skills, developments in machine learning show that computer models can also make valid judgments. This study compares the accuracy of human and computer-based personality judgments, using a sample of 86,220 volunteers who completed a 100-item personality questionnaire. We show that (i) computer predictions based on a generic digital footprint (Facebook Likes) are more accurate (r = 0.56) than those made by the participants' Facebook friends using a personality questionnaire (r = 0.49); (ii) computer models show higher interjudge agreement; and (iii) computer personality judgments have higher external validity when predicting life outcomes such as substance use, political attitudes, and physical health; for some outcomes, they even outperform the self-rated personality scores. Computers outpacing humans in personality judgment presents significant opportunities and challenges in the areas of psychological assessment, marketing, and privacy.

  6. Plant Disease Severity Assessment-How Rater Bias, Assessment Method, and Experimental Design Affect Hypothesis Testing and Resource Use Efficiency.

    Science.gov (United States)

    Chiang, Kuo-Szu; Bock, Clive H; Lee, I-Hsuan; El Jarroudi, Moussa; Delfosse, Philippe

    2016-12-01

    The effect of rater bias and assessment method on hypothesis testing was studied for representative experimental designs for plant disease assessment using balanced and unbalanced data sets. Data sets with the same number of replicate estimates for each of two treatments are termed "balanced" and those with unequal numbers of replicate estimates are termed "unbalanced". The three assessment methods considered were nearest percent estimates (NPEs), an amended 10% incremental scale, and the Horsfall-Barratt (H-B) scale. Estimates of severity of Septoria leaf blotch on leaves of winter wheat were used to develop distributions for a simulation model. The experimental designs are presented here in the context of simulation experiments which consider the optimal design for the number of specimens (individual units sampled) and the number of replicate estimates per specimen for a fixed total number of observations (total sample size for the treatments being compared). The criterion used to gauge each method was the power of the hypothesis test. As expected, at a given fixed number of observations, the balanced experimental designs invariably resulted in a higher power compared with the unbalanced designs at different disease severity means, mean differences, and variances. Based on these results, with unbiased estimates using NPE, the recommended number of replicate estimates taken per specimen is 2 (from a sample of specimens of at least 30), because this conserves resources. Furthermore, for biased estimates, an apparent difference in the power of the hypothesis test was observed between assessment methods and between experimental designs. Results indicated that, regardless of experimental design or rater bias, an amended 10% incremental scale has slightly less power compared with NPEs, and that the H-B scale is more likely than the others to cause a type II error. These results suggest that choice of assessment method, optimizing sample number and number of replicate

  7. Accurately controlled sequential self-folding structures by polystyrene film

    Science.gov (United States)

    Deng, Dongping; Yang, Yang; Chen, Yong; Lan, Xing; Tice, Jesse

    2017-08-01

    Four-dimensional (4D) printing overcomes the traditional fabrication limitations by designing heterogeneous materials to enable the printed structures evolve over time (the fourth dimension) under external stimuli. Here, we present a simple 4D printing of self-folding structures that can be sequentially and accurately folded. When heated above their glass transition temperature pre-strained polystyrene films shrink along the XY plane. In our process silver ink traces printed on the film are used to provide heat stimuli by conducting current to trigger the self-folding behavior. The parameters affecting the folding process are studied and discussed. Sequential folding and accurately controlled folding angles are achieved by using printed ink traces and angle lock design. Theoretical analyses are done to guide the design of the folding processes. Programmable structures such as a lock and a three-dimensional antenna are achieved to test the feasibility and potential applications of this method. These self-folding structures change their shapes after fabrication under controlled stimuli (electric current) and have potential applications in the fields of electronics, consumer devices, and robotics. Our design and fabrication method provides an easy way by using silver ink printed on polystyrene films to 4D print self-folding structures for electrically induced sequential folding with angular control.

  8. Fast and accurate methods for the performance testing of highly-efficient c-Si photovoltaic modules using a 10 ms single-pulse solar simulator and customized voltage profiles

    International Nuclear Information System (INIS)

    Virtuani, A; Rigamonti, G; Friesen, G; Chianese, D; Beljean, P

    2012-01-01

    Performance testing of highly efficient, highly capacitive c-Si modules with pulsed solar simulators requires particular care. These devices in fact usually require a steady-state solar simulator or pulse durations longer than 100–200 ms in order to avoid measurement artifacts. The aim of this work was to validate an alternative method for the testing of highly capacitive c-Si modules using a 10 ms single pulse solar simulator. Our approach attempts to reconstruct a quasi-steady-state I–V (current–voltage) curve of a highly capacitive device during one single 10 ms flash by applying customized voltage profiles–-in place of a conventional V ramp—to the terminals of the device under test. The most promising results were obtained by using V profiles which we name ‘dragon-back’ (DB) profiles. When compared to the reference I–V measurement (obtained by using a multi-flash approach with approximately 20 flashes), the DB V profile method provides excellent results with differences in the estimation of P max (as well as of I sc , V oc and FF) below ±0.5%. For the testing of highly capacitive devices the method is accurate, fast (two flashes—possibly one—required), cost-effective and has proven its validity with several technologies making it particularly interesting for in-line testing. (paper)

  9. Standardized assessment of infrared thermographic fever screening system performance

    Science.gov (United States)

    Ghassemi, Pejhman; Pfefer, Joshua; Casamento, Jon; Wang, Quanzeng

    2017-03-01

    Thermal modalities represent the only currently viable mass fever screening approach for outbreaks of infectious disease pandemics such as Ebola and SARS. Non-contact infrared thermometers (NCITs) and infrared thermographs (IRTs) have been previously used for mass fever screening in transportation hubs such as airports to reduce the spread of disease. While NCITs remain a more popular choice for fever screening in the field and at fixed locations, there has been increasing evidence in the literature that IRTs can provide greater accuracy in estimating core body temperature if appropriate measurement practices are applied - including the use of technically suitable thermographs. Therefore, the purpose of this study was to develop a battery of evaluation test methods for standardized, objective and quantitative assessment of thermograph performance characteristics critical to assessing suitability for clinical use. These factors include stability, drift, uniformity, minimum resolvable temperature difference, and accuracy. Two commercial IRT models were characterized. An external temperature reference source with high temperature accuracy was utilized as part of the screening thermograph. Results showed that both IRTs are relatively accurate and stable (<1% error of reading with stability of +/-0.05°C). Overall, results of this study may facilitate development of standardized consensus test methods to enable consistent and accurate use of IRTs for fever screening.

  10. An assessment of biodegradability of quaternary carbon-containing fragrance compounds: comparison of experimental OECD screening test results and in silico prediction data.

    Science.gov (United States)

    Seyfried, Markus; Boschung, Alain

    2014-05-01

    An assessment of biodegradability was carried out for fragrance substances containing quaternary carbons by using data obtained from Organisation for Economic Co-operation and Development (OECD) 301F screening tests for ready biodegradation and from Biowin and Catalogic prediction models. Despite an expected challenging profile, a relatively high percentage of common-use fragrance substances showed significant biodegradation under the stringent conditions applied in the OECD 301F test. Among 27 test compounds, 37% met the pass level criteria after 28 d, while another 26% indicated partial breakdown (≥20% biodegradation). For several compounds for which structural analogs were available, the authors found that structures that were rendered less water soluble by either the presence of an acetate ester or the absence of oxygen tended to degrade to a lesser extent compared to the primary alcohols or oxygenated counterparts under the test conditions applied. Difficulties were encountered when attempting to correlate experimental with in silico data. Whereas the Biowin model combinations currently recommended by regulatory agencies did not allow for a reliable discrimination between readily and nonbiodegradable compounds, only a comparably small proportion of the chemicals studied (30% and 63% depending on the model) fell within the applicability domain of Catalogic, a factor that critically reduced its predictive power. According to these results, currently neither Biowin nor Catalogic accurately reflects the potential for biodegradation of fragrance compounds containing quaternary carbons. © 2014 SETAC.

  11. Interrater reliability assessment using the Test of Gross Motor Development-2.

    Science.gov (United States)

    Barnett, Lisa M; Minto, Christine; Lander, Natalie; Hardy, Louise L

    2014-11-01

    The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Reliability Study--cross sectional. Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. A total of 37 children (65% girls) aged 4-8 years (M = 6.2, SD = 0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC = 0.93), and for individual skills, highest for the dribble (ICC = 0.94) followed by strike (ICC = 0.85), overhand throw (ICC = 0.84), underhand roll (ICC = 0.82), kick (ICC = 0.80) and the catch (ICC = 0.71). The strike and the throw had more components with less agreement. Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  12. Normative Values of Balance Tests in Neurological Assessment of Sports Related Concussions

    Directory of Open Access Journals (Sweden)

    Samaneh Eemanipure

    2011-04-01

    Full Text Available Objectives: Deterioration in postural control mechanisms is termed postural instability and results increased postural sway and many laboratory techniques and instruments are characterized by a wide range of neurological signs and symptoms to the medical management. Thus the current study designed to assess the reliability of commonly used clinical measures of balance and determined normal values. Also, the second purpose was to evaluate the scrutiny of age, length weight and body mass index (BMI effects on performing clinical balance tests. Methods: One hundred and thirty three participants (18-59 years, that have at least three time sports activity in one week, performed three timed tests including Time-up and Go (TUG, Tandem Gait (TG, and Walking on Balance Beam (WOBB on firm surface. Results: Reliability data were produced for each tests of motor performance. We found that the first performance of three trials was slower, and the relationship between some factors and these battery tests were examined. Means(±SD for each measure were averaged across three trials. Time to complete TG was 13.6±1.1s. TUG value was 6.9±1.03 and WOBB was 6.9±1.03s. Discussion: our results revealed that three clinical balance test batteries-TUG, TG and WOBB tests are the stability measures to assess the sports related concussion. Also, the results of current study showed that the time to perform these tests was slower than the other studies.

  13. Stereotype Threat, Inquiring about Test Takers' Race and Gender, and Performance on Low-Stakes Tests in a Large-Scale Assessment. Research Report. ETS RR-15-02

    Science.gov (United States)

    Stricker, Lawrence J.; Rock, Donald A.; Bridgeman, Brent

    2015-01-01

    This study explores stereotype threat on low-stakes tests used in a large-scale assessment, math and reading tests in the Education Longitudinal Study of 2002 (ELS). Issues identified in laboratory research (though not observed in studies of high-stakes tests) were assessed: whether inquiring about their race and gender is related to the…

  14. Tools for Accurate and Efficient Analysis of Complex Evolutionary Mechanisms in Microbial Genomes. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Nakhleh, Luay

    2014-03-12

    I proposed to develop computationally efficient tools for accurate detection and reconstruction of microbes' complex evolutionary mechanisms, thus enabling rapid and accurate annotation, analysis and understanding of their genomes. To achieve this goal, I proposed to address three aspects. (1) Mathematical modeling. A major challenge facing the accurate detection of HGT is that of distinguishing between these two events on the one hand and other events that have similar "effects." I proposed to develop a novel mathematical approach for distinguishing among these events. Further, I proposed to develop a set of novel optimization criteria for the evolutionary analysis of microbial genomes in the presence of these complex evolutionary events. (2) Algorithm design. In this aspect of the project, I proposed to develop an array of e cient and accurate algorithms for analyzing microbial genomes based on the formulated optimization criteria. Further, I proposed to test the viability of the criteria and the accuracy of the algorithms in an experimental setting using both synthetic as well as biological data. (3) Software development. I proposed the nal outcome to be a suite of software tools which implements the mathematical models as well as the algorithms developed.

  15. WATCH: Warwick Assessment insTrument for Clinical teacHing: Development and testing.

    Science.gov (United States)

    Haider, Sonia Ijaz; Johnson, Neil; Thistlethwaite, Jill Elizabeth; Fagan, Gay; Bari, Muhammad Furqan

    2015-03-01

    Medical education and teaching skills are core competencies included in the generic curriculum for specialty training. To support the development of these skills, there is need for a validated instrument. This study aims to develop and test an instrument to measure the attributes of specialty trainees as effective teachers. The study was conducted in two phases. In first phase, the content of the instrument was generated from the literature and tested using the Delphi technique. In second phase, the instrument was field tested for validity and reliability using factor analysis and generalizability study. Feasibility was calculated by the time taken to complete the instrument. Acceptability and educational impact were determined by qualitative analysis of written feedback. Attributes of specialty trainees were assessed by clinical supervisors, peers, and students. The Delphi study produced consensus on 15 statements which formed the basis of the instrument. In field study, a total of 415 instruments were completed. Factor analysis demonstrated a three-factor solution ('learning-teaching milieu', 'teaching skills', and 'learner-orientated'). A generalizability coefficient was 0.92. Mean time to complete the instrument was five minutes. Feedback indicated that it was an acceptable and useful method of assessment. This new instrument provides valid, reliable, feasible, and acceptable assessment of clinical teaching.

  16. The paced auditory serial addition test for working memory assessment: Psychometric properties

    Science.gov (United States)

    Nikravesh, Maryam; Jafari, Zahra; Mehrpour, Masoud; Kazemi, Roozbeh; Amiri Shavaki, Younes; Hossienifar, Shamim; Azizi, Mohamad Parsa

    2017-01-01

    Background: The paced auditory serial addition test (PASAT) was primarily developed to assess the effects of traumatic brain injury on cognitive functioning. Working memory (WM) is one of the most important aspects of cognitive function, and WM impairment is one of the clinically remarkable signs of aphasia. To develop the Persian version of PASAT, an initial version was used in individuals with aphasia (IWA). Methods: In this study, 25 individuals with aphasia (29-60 years) and 85 controls (18-60 years) were included. PASAT was presented in the form of recorded 61 single-digit numbers (1 to 9). The participants repeatedly added the 2 recent digits. The psychometric properties of PASAT including convergent validity (using the digit memory span tasks), divergent validity (using results in the control group and IWA group), and face validity were investigated. Test-retest reliability was considered as well. Results: The relationship between the PASAT and digit memory span tests was moderate to strong in the control group (forward digit memory span test: r= 0.52, p< 0.0001; backward digit memory span test: r = 0.48, p< 0.0001). A strong relationship was found in IWA (forward digit memory span test: r= 0.72, p< 0.0001; backward digit memory span test: r= 0.53, p= 0.006). Also, strong testretest reliability (intraclass correlation= 0.95, p< 0.0001) was observed. Conclusion: According to our results, the PASAT is a valid and reliable test to assess working memory, particularly in IWA. It could be used as a feasible tool for clinical and research applications. PMID:29445690

  17. Bursting tests on pressure vessels with cracks differing in configuration and location

    International Nuclear Information System (INIS)

    Stahlberg, R.

    1978-01-01

    For assessing the safety of nuclear pressure vessels exhibiting cracks, bursting test were carried out on a series of medium-size pressure vessels with and without welded nozzles and exhibiting cracks differing in configuration and location. The linear-elastic approach proved to be sufficiently accurate for straight strain conditions up to the onset of general yielding. Other analytical methods were successfully used to cover the plastic region. (orig.) [de

  18. An assessment of quality of home-based HIV counseling and testing ...

    African Journals Online (AJOL)

    An assessment of quality of home-based HIV counseling and testing performed by lay counselors in a rural sub-district of KwaZulu-Natal, South Africa. ... AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians ...

  19. Quality of education and memory test performance in older men: the New York University Paragraph Recall Test normative data.

    Science.gov (United States)

    Mathews, Melissa; Abner, Erin; Caban-Holt, Allison; Dennis, Brandon C; Kryscio, Richard; Schmitt, Frederick

    2013-09-01

    Memory evaluation is a key component in the accurate diagnosis of cognitive disorders.One memory procedure that has shown promise in discriminating disease-related cognitive decline from normal cognitive aging is the New York University Paragraph Recall Test; however, the effects of education have been unexamined as they pertain to one's literacy level. The current study provides normative data stratified by estimated quality of education as indexed by irregular word reading skill. Conventional norms were derived from a sample (N = 385) of cognitively intact elderly men who were initially recruited for participation in the PREADViSE clinical trial. A series of multiple linear regression models were constructed to assess the influence of demographic variables on mean NYU Paragraph Immediate and Delayed Recall scores. Test version, assessment site, and estimated quality of education were significant predictors of performance on the NYU Paragraph Recall Test. Findings indicate that estimated quality of education is a better predictor of memory performance than ethnicity and years of total education. Normative data stratified according to estimated quality of education are presented. The current study provides evidence and support for normativedata stratified by quality of education as opposed to years of education.

  20. Alternative test method to assess the energy performance of frost-free refrigerating appliances

    International Nuclear Information System (INIS)

    Hermes, Christian J.L.; Melo, Cláudio; Knabben, Fernando T.

    2013-01-01

    This paper outlines an alternative test method to evaluate the energy consumption of frost-free refrigerators and freezers for residential applications. While the standardized methods require the refrigerating appliance to be kept running according to its onboard control system, which usually drives the refrigerator through an on–off cycling pattern, the proposed approach assesses the refrigerator energy performance in the steady-state regime, being therefore much faster and more reliable. In this procedure, the cooling capacity is matched to the cooling loads by PID-controlled electrical heaters installed within the refrigerated compartments, so that the compartment temperatures are kept at the desired standardized levels. Comparisons between the experimental results obtained using the steady-state energy test and the standardized procedures showed that the former follows closely the trends observed for the latter. - Highlights: ► An alternative test method to assess the energy consumption of refrigerators is proposed. ► PID-controlled electrical heaters were installed within the compartments. ► Steady-state and ISO energy tests were performed and compared. ► Both proposed and standardized test procedures showed similar trends.

  1. 78 FR 29698 - Availability of an Environmental Assessment for Field Testing a Canine Lymphoma Vaccine, DNA

    Science.gov (United States)

    2013-05-21

    ...] Availability of an Environmental Assessment for Field Testing a Canine Lymphoma Vaccine, DNA AGENCY: Animal and... Canine Lymphoma Vaccine, DNA. The environmental assessment, which is based on a risk analysis prepared to... biological product: Requester: Merial, Inc. Product: Canine Lymphoma Vaccine, DNA. Possible Field Test...

  2. Adaptation of the ToxRTool to Assess the Reliability of Toxicology Studies Conducted with Genetically Modified Crops and Implications for Future Safety Testing.

    Science.gov (United States)

    Koch, Michael S; DeSesso, John M; Williams, Amy Lavin; Michalek, Suzanne; Hammond, Bruce

    2016-01-01

    To determine the reliability of food safety studies carried out in rodents with genetically modified (GM) crops, a Food Safety Study Reliability Tool (FSSRTool) was adapted from the European Centre for the Validation of Alternative Methods' (ECVAM) ToxRTool. Reliability was defined as the inherent quality of the study with regard to use of standardized testing methodology, full documentation of experimental procedures and results, and the plausibility of the findings. Codex guidelines for GM crop safety evaluations indicate toxicology studies are not needed when comparability of the GM crop to its conventional counterpart has been demonstrated. This guidance notwithstanding, animal feeding studies have routinely been conducted with GM crops, but their conclusions on safety are not always consistent. To accurately evaluate potential risks from GM crops, risk assessors need clearly interpretable results from reliable studies. The development of the FSSRTool, which provides the user with a means of assessing the reliability of a toxicology study to inform risk assessment, is discussed. Its application to the body of literature on GM crop food safety studies demonstrates that reliable studies report no toxicologically relevant differences between rodents fed GM crops or their non-GM comparators.

  3. Risk assessment of forensic patients: nurses' role.

    Science.gov (United States)

    Encinares, Maxima; McMaster, Jeff James; McNamee, Jim

    2005-03-01

    One of the unique roles of forensic nurses is to conduct risk assessments. Establishing a therapeutic nurse-patient relationship helps forensic nurses perform accurate and useful risk assessments. Accurate risk assessments can facilitate formulation of individualized risk management plans, designed to meet patients' needs and ensure public safety. The importance of forensic nurses' knowledge and application of appropriate communication and proper documentation cannot be overemphasized.

  4. Scaling analysis for the OSU AP600 test facility (APEX)

    International Nuclear Information System (INIS)

    Reyes, J.N.

    1998-01-01

    In this paper, the authors summarize the key aspects of a state-of-the-art scaling analysis (Reyes et al. (1995)) performed to establish the facility design and test conditions for the advanced plant experiment (APEX) at Oregon State University (OSU). This scaling analysis represents the first, and most comprehensive, application of the hierarchical two-tiered scaling (H2TS) methodology (Zuber (1991)) in the design of an integral system test facility. The APEX test facility, designed and constructed on the basis of this scaling analysis, is the most accurate geometric representation of a Westinghouse AP600 nuclear steam supply system. The OSU APEX test facility has served to develop an essential component of the integral system database used to assess the AP600 thermal hydraulic safety analysis computer codes. (orig.)

  5. Assessment of implicit personality self-concept using the implicit association test (IAT): concurrent assessment of anxiousness and angriness.

    Science.gov (United States)

    Schnabel, Konrad; Banse, Rainer; Asendorpf, Jens B

    2006-06-01

    This study explored the psychometric properties of the Implicit Association Test (IAT) when it is employed for the assessment of two personality traits within one sample. The sequence of an anxiousness and an angriness IAT was counterbalanced across 100 participants and the IATs' predictive validity for anxious versus angry behaviour after emotion inductions was examined and compared to direct self-report measures. The anxiousness IAT added incremental validity over direct measures for the prediction of anxious behaviour. The angriness IAT was affected by an order effect. When the angriness IAT was completed after the anxiousness IAT both tests correlated with r=.46 whereas they were not significantly correlated when the angriness IAT was completed first. Direct anxiousness and angriness measures were uncorrelated. Implications for the assessment of multiple implicit personality self-concept dimensions are discussed.

  6. Dose assessment, radioecology, and community interaction at former nuclear test sites

    International Nuclear Information System (INIS)

    Robison, W.L.

    1994-11-01

    The US conducted a nuclear testing program at Bikini and Enewetak Atolls in the Marshall Islands from 1946 through 1958. A total of 66 nuclear devices were tested--23 at Bikini Atoll (total yield of 77 megatons) and 43 at Enewetak Atoll (total yield of 33 megatons). This resulted in contamination of many of the islands at each atoll. The BRAVO test (yield 15 megatons) on March 1, 1954 contaminated several atolls to the east of Bikini Atoll some of which were inhabited. The author has conducted an experimental, monitoring, and dose assessment program at atolls in the northern Marshall Islands for the past 20 years. The goals have been to: (1) determine the radiological conditions at the atolls; (2) provide dose assessments for resettlement options and alternate living patterns; (3) develop and evaluate remedial measures to reduce the dose to people reinhabiting the atolls; and (4) discuss the results with each of the communities and the Republic of the Marshall Islands government officials to help them understand the data as a basis for resettlement decisions. The remaining radionuclides at the atolls that contribute any significant dose are 137 Cs, 90 Sr, 239+240 Pu, and 241 Am

  7. Test-Retest Reliability of the Preschool Age Psychiatric Assessment (PAPA)

    Science.gov (United States)

    Egger, Helen Link; Erkanli, Alaattin; Keeler, Gordon; Potts, Edward; Walter, Barbara Keith; Angold, Adrian

    2006-01-01

    Objective: To examine the test-retest reliability of a new interviewer-based psychiatric diagnostic measure (the Preschool Age Psychiatric Assessment) for use with parents of preschoolers 2 to 5 years old. Method: A total of 1,073 parents of children attending a large pediatric clinic completed the Child Behavior Checklist 1 1/2-5. For 18 months,…

  8. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  9. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  10. Accurate recapture identification for genetic mark–recapture studies with error-tolerant likelihood-based match calling and sample clustering

    Science.gov (United States)

    Sethi, Suresh; Linden, Daniel; Wenburg, John; Lewis, Cara; Lemons, Patrick R.; Fuller, Angela K.; Hare, Matthew P.

    2016-01-01

    Error-tolerant likelihood-based match calling presents a promising technique to accurately identify recapture events in genetic mark–recapture studies by combining probabilities of latent genotypes and probabilities of observed genotypes, which may contain genotyping errors. Combined with clustering algorithms to group samples into sets of recaptures based upon pairwise match calls, these tools can be used to reconstruct accurate capture histories for mark–recapture modelling. Here, we assess the performance of a recently introduced error-tolerant likelihood-based match-calling model and sample clustering algorithm for genetic mark–recapture studies. We assessed both biallelic (i.e. single nucleotide polymorphisms; SNP) and multiallelic (i.e. microsatellite; MSAT) markers using a combination of simulation analyses and case study data on Pacific walrus (Odobenus rosmarus divergens) and fishers (Pekania pennanti). A novel two-stage clustering approach is demonstrated for genetic mark–recapture applications. First, repeat captures within a sampling occasion are identified. Subsequently, recaptures across sampling occasions are identified. The likelihood-based matching protocol performed well in simulation trials, demonstrating utility for use in a wide range of genetic mark–recapture studies. Moderately sized SNP (64+) and MSAT (10–15) panels produced accurate match calls for recaptures and accurate non-match calls for samples from closely related individuals in the face of low to moderate genotyping error. Furthermore, matching performance remained stable or increased as the number of genetic markers increased, genotyping error notwithstanding.

  11. Development of the Central Dogma Concept Inventory (CDCI) Assessment Tool

    OpenAIRE

    Newman, Dina L.; Snyder, Christopher W.; Fisk, J. Nick; Wright, L. Kate

    2016-01-01

    Scientific teaching requires scientifically constructed, field-tested instruments to accurately evaluate student thinking and gauge teacher effectiveness. We have developed a 23-question, multiple select?format assessment of student understanding of the essential concepts of the central dogma of molecular biology that is appropriate for all levels of undergraduate biology. Questions for the Central Dogma Concept Inventory (CDCI) tool were developed and iteratively revised based on student lan...

  12. Presurgical assessment of spina bifida

    International Nuclear Information System (INIS)

    Stack, J.P.; Fitzgerald, P.; Redmond, O.; Ennis, J.T.

    1989-01-01

    Twenty-five children (mean age, 8 years) with spina bifida (occult in 10), who were under active consideration for surgical intervention became of clinical deterioration have been assessed with MR imaging. T1-weighted spin-echo (SE) images (500/17 [repetition time msec/echo time msec]) were obtained in at least two planes. T2-weighted SE sequences were reserved for further tissue characterization. Anomalies detected requiring surgical review included diastematomyelia (n = 6), tethered cord (n = 10), hydromyelia (n = 4), and cord cyst (n = 1). Eight were not considered for surgery (cord atrophy and small hydromyelias). Diastem spurs were best identified on CT. MR imaging provided accurate preoperative assessment (11 of 13 cases) and will replace invasive tests, which should now be reserved for those cases where MR imaging does not elucidate the clinical signs

  13. Development of Android apps for cognitive assessment of dementia and delirium.

    Science.gov (United States)

    Weir, Alexander J; Paterson, Craig A; Tieges, Zoe; MacLullich, Alasdair M; Parra-Rodriguez, Mario; Della Sala, Sergio; Logie, Robert H

    2014-01-01

    The next generation of medical technology applications for hand-held portable platforms will provide a core change in performance and sophistication, transforming the way health care professionals interact with patients. This advance is particularly apparent in the delivery of cognitive patient assessments, where smartphones and tablet computers are being used to assess complex neurological conditions to provide objective, accurate and reproducible test results. This paper reports on two such applications (apps) that have been developed to assist healthcare professionals with the detection and diagnosis of dementia and delirium.

  14. Seizure semiology inferred from clinical descriptions and from video recordings. How accurate are they?

    DEFF Research Database (Denmark)

    Beniczky, Simona Alexandra; Fogarasi, András; Neufeld, Miri

    2012-01-01

    To assess how accurate the interpretation of seizure semiology is when inferred from witnessed seizure descriptions and from video recordings, five epileptologists analyzed 41 seizures from 30 consecutive patients who had clinical episodes in the epilepsy monitoring unit. For each clinical episode...... for the descriptions (k=0.67) and almost perfect for the video recordings (k=0.95). Video recordings significantly increase the accuracy of seizure interpretation....

  15. Assessing CO2 emissions of electric vehicles for e-sharing and home care. Two cases developed at Valencian region

    Energy Technology Data Exchange (ETDEWEB)

    Iacono Ferreira, V.G. Lo; Torregrosa Lopez, J.I.; Colomer Ferrandiz, J.V.

    2016-07-01

    Assessing the environmental impact of transport has been an issue over the last decade. The general framework is established and the followings factors must be considered to obtain results as accurate as possible. Among others (a) the study should considered the entire life cycle if possible: building & materials, usage phase and waste treatment and (b) usage phase assessment must be developed under real conditions in addition to lab tests. When the object of study is urban private transport, some extra lines can be taken into account considering the high impact that environmental initiatives makes in society. The information that local authorities and community receives about the initiative is as relevant as the environmental benefits obtain of the implementation of the project. In this paper, we present the methodology developed to assess CO2 emissions of electric vehicles intendent to car-sharing and home care; two projects developed at Valencian region. We deepen in the relevance and type of information obtain and manage for both studies with a life cycle vision. As a result of usage phase assessment, field test proves to be revealing giving a more realistic vision of the benefits of the project. Theoretical assessments were useful to consider the implementation of a certain project and the necessary support complementing the entity of the study. Resources needed to develop field test might skew results by biasing the study. Attention need to be paid in order to manage resources to set up field tests and avoid setting up field tests due to available resources. Bibliographic studies have shown building, materials and waste treatment depends on available data. Life cycle assessment seems to be the most adequate tool to obtain accurate results although the cost of the assessment is high and might not show significant differences between cars of similar characteristics. (Author)

  16. State-of-the-art assessment of testing and testability of custom LSI/VLSI circuits. Volume 8: Fault simulation

    Science.gov (United States)

    Breuer, M. A.; Carlan, A. J.

    1982-10-01

    Fault simulation is widely used by industry in such applications as scoring the fault coverage of test sequences and construction of fault dictionaries. For use in testing VLSI circuits a simulator is evaluated by its accuracy, i.e., modelling capability. To be accurate simulators must employ multi-valued logic in order to represent unknown signal values, impedance, signal transitions, etc., circuit delays such as transport rise/fall, inertial, and the fault modes it is capable of handling. Of the three basic fault simulators now in use (parallel, deductive and concurrent) concurrent fault simulation appears most promising.

  17. Requirements for accurately diagnosing chronic partial upper urinary tract obstruction in children with hydronephrosis

    International Nuclear Information System (INIS)

    Koff, Stephen A.

    2008-01-01

    Successful management of hydronephrosis in the newborn requires early accurate diagnosis to identify or exclude ureteropelvic junction obstruction. However, the presence of hydronephrosis does not define obstruction and displays unique behavior in the newborn. The hydronephrotic kidney usually has nearly normal differential renal function at birth, has not been subjected to progressive dilation and except for pelvocaliectasis does not often show signs of high-grade obstruction. Furthermore, severe hydronephrosis resolves spontaneously in more than 65% of newborns with differential renal function stable or improving. The diagnosis of obstruction in newborn hydronephrosis is challenging because the currently available diagnostic tests, ultrasonography and diuretic renography have demonstrated inaccuracy in diagnosing obstruction and predicting which hydronephrotic kidney will undergo deterioration if untreated. Accurate diagnosis of obstruction is possible but it requires an understanding of the uniqueness of both the pathophysiology of obstruction and the biology of the kidney and renal collecting system in this age group. We examine here the requirements for making an accurate diagnosis of obstruction in the young child with hydronephrosis. (orig.)

  18. Requirements for accurately diagnosing chronic partial upper urinary tract obstruction in children with hydronephrosis

    Energy Technology Data Exchange (ETDEWEB)

    Koff, Stephen A. [Ohio State University College of Medicine, Section of Pediatric Urology, Columbus Children' s Hospital, Columbus, OH (United States)

    2008-01-15

    Successful management of hydronephrosis in the newborn requires early accurate diagnosis to identify or exclude ureteropelvic junction obstruction. However, the presence of hydronephrosis does not define obstruction and displays unique behavior in the newborn. The hydronephrotic kidney usually has nearly normal differential renal function at birth, has not been subjected to progressive dilation and except for pelvocaliectasis does not often show signs of high-grade obstruction. Furthermore, severe hydronephrosis resolves spontaneously in more than 65% of newborns with differential renal function stable or improving. The diagnosis of obstruction in newborn hydronephrosis is challenging because the currently available diagnostic tests, ultrasonography and diuretic renography have demonstrated inaccuracy in diagnosing obstruction and predicting which hydronephrotic kidney will undergo deterioration if untreated. Accurate diagnosis of obstruction is possible but it requires an understanding of the uniqueness of both the pathophysiology of obstruction and the biology of the kidney and renal collecting system in this age group. We examine here the requirements for making an accurate diagnosis of obstruction in the young child with hydronephrosis. (orig.)

  19. Environmental assessment of SP-100 ground engineering system test site: Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1988-12-01

    The US Department of Energy (DOE) proposes to modify an existing reactor containment building (decommissioned Plutonium Recycle Test Reactor (PRTR) 309 Building) to provide ground test capability for the prototype SP-100 reactor. The 309 Building (Figure 1.1) is located in the 300 Area on the Hanford Site in Washington State. The National Environmental Policy Act (NEPA) requires that Federal agencies assess the potential impacts that their actions may have on the environment. This Environmental Assessment describes the consideration given to environmental impacts during reactor concept and test site selection, examines the environmental effects of the DOE proposal to ground test the nuclear subsystem, describes alternatives to the proposed action, and examines radiological risks of potential SP-100 use in space. 73 refs., 19 figs., 7 tabs.

  20. An efficient and accurate 3D displacements tracking strategy for digital volume correlation

    Science.gov (United States)

    Pan, Bing; Wang, Bo; Wu, Dafang; Lubineau, Gilles

    2014-07-01

    Owing to its inherent computational complexity, practical implementation of digital volume correlation (DVC) for internal displacement and strain mapping faces important challenges in improving its computational efficiency. In this work, an efficient and accurate 3D displacement tracking strategy is proposed for fast DVC calculation. The efficiency advantage is achieved by using three improvements. First, to eliminate the need of updating Hessian matrix in each iteration, an efficient 3D inverse compositional Gauss-Newton (3D IC-GN) algorithm is introduced to replace existing forward additive algorithms for accurate sub-voxel displacement registration. Second, to ensure the 3D IC-GN algorithm that converges accurately and rapidly and avoid time-consuming integer-voxel displacement searching, a generalized reliability-guided displacement tracking strategy is designed to transfer accurate and complete initial guess of deformation for each calculation point from its computed neighbors. Third, to avoid the repeated computation of sub-voxel intensity interpolation coefficients, an interpolation coefficient lookup table is established for tricubic interpolation. The computational complexity of the proposed fast DVC and the existing typical DVC algorithms are first analyzed quantitatively according to necessary arithmetic operations. Then, numerical tests are performed to verify the performance of the fast DVC algorithm in terms of measurement accuracy and computational efficiency. The experimental results indicate that, compared with the existing DVC algorithm, the presented fast DVC algorithm produces similar precision and slightly higher accuracy at a substantially reduced computational cost.

  1. An efficient and accurate 3D displacements tracking strategy for digital volume correlation

    KAUST Repository

    Pan, Bing

    2014-07-01

    Owing to its inherent computational complexity, practical implementation of digital volume correlation (DVC) for internal displacement and strain mapping faces important challenges in improving its computational efficiency. In this work, an efficient and accurate 3D displacement tracking strategy is proposed for fast DVC calculation. The efficiency advantage is achieved by using three improvements. First, to eliminate the need of updating Hessian matrix in each iteration, an efficient 3D inverse compositional Gauss-Newton (3D IC-GN) algorithm is introduced to replace existing forward additive algorithms for accurate sub-voxel displacement registration. Second, to ensure the 3D IC-GN algorithm that converges accurately and rapidly and avoid time-consuming integer-voxel displacement searching, a generalized reliability-guided displacement tracking strategy is designed to transfer accurate and complete initial guess of deformation for each calculation point from its computed neighbors. Third, to avoid the repeated computation of sub-voxel intensity interpolation coefficients, an interpolation coefficient lookup table is established for tricubic interpolation. The computational complexity of the proposed fast DVC and the existing typical DVC algorithms are first analyzed quantitatively according to necessary arithmetic operations. Then, numerical tests are performed to verify the performance of the fast DVC algorithm in terms of measurement accuracy and computational efficiency. The experimental results indicate that, compared with the existing DVC algorithm, the presented fast DVC algorithm produces similar precision and slightly higher accuracy at a substantially reduced computational cost. © 2014 Elsevier Ltd.

  2. Esophageal function testing: Billing and coding update.

    Science.gov (United States)

    Khan, A; Massey, B; Rao, S; Pandolfino, J

    2018-01-01

    Esophageal function testing is being increasingly utilized in diagnosis and management of esophageal disorders. There have been several recent technological advances in the field to allow practitioners the ability to more accurately assess and treat such conditions, but there has been a relative lack of education in the literature regarding the associated Common Procedural Terminology (CPT) codes and methods of reimbursement. This review, commissioned and supported by the American Neurogastroenterology and Motility Society Council, aims to summarize each of the CPT codes for esophageal function testing and show the trends of associated reimbursement, as well as recommend coding methods in a practical context. We also aim to encourage many of these codes to be reviewed on a gastrointestinal (GI) societal level, by providing evidence of both discrepancies in coding definitions and inadequate reimbursement in this new era of esophageal function testing. © 2017 John Wiley & Sons Ltd.

  3. Assessing clinical reasoning in optometry using the script concordance test.

    Science.gov (United States)

    Faucher, Caroline; Dufour-Guindon, Marie-Pier; Lapointe, Gabrielle; Gagnon, Robert; Charlin, Bernard

    2016-05-01

    Clinical reasoning is central to any health profession but its development among learners is difficult to assess. Over the last few decades, the script concordance test (SCT) has been developed to solve this dilemma and has been used in many health professions; however, no study has been published on the use of the script concordance test in optometry. The purpose of this study was to develop and validate a script concordance test for the field of optometry. A 101-question script concordance test (27 short clinical scenarios) was developed and administered online to a convenience sample of 23 second-year and 19 fourth-year students of optometry. It was also administered to a reference panel of 12 experienced optometrists to develop the scoring key. An item-total correlation was calculated for each question. Cronbach's alpha coefficient was used to evaluate the script concordance test reliability and a t-test compared the two groups. A final 77-question script concordance test was created by eliminating questions with low item-total correlation. Cronbach's alpha for this optimised 77-question script concordance test was 0.80. A group comparison revealed that the second-year students' scores (n = 23; mean score = 66.4 ± 7.87 per cent) were statistically lower (t = -4.141; p Optometry © 2016 Optometry Australia.

  4. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  5. How accurate are self‐reported smoking habits in patients with tuberculosis?

    Directory of Open Access Journals (Sweden)

    Cope GF

    2017-01-01

    Full Text Available Background Smoking or chewing tobacco is a global public health problem that is becoming increasingly prevalent in developing countries. These same countries often also have high rates of tuberculosis disease and infection. As smoking can adversely affect tuberculosis severity, response to treatment and relapse, it is therefore important that clinicians have an accurate picture of patients’ smoking habits. Self‐reported smoking habits may be unreliable and objective measurements of tobacco exposure more accurate. Objective To determine the reliability of self‐reported smoking habits in patients with tuberculosis by measurement of urinary cotinine levels, an objective measure of tobacco exposure. Methods Self‐reported tobacco use was recorded in 100 patients receiving treatment for active or latent tuberculosis using an interviewer administered ‘questionnaire. Urinary cotinine levels were measured by the SmokeScreen test 24hours after the end of treatment. Findings Of 81 reported non‐smokers, 10 had a positive test for cotinine, six of whom gave a result indicative of heavy (11‐15 cigarettes/day or very heavy (>16/day smoking. Of the 17 self‐confessed smokers and two chewers of tobacco, nine gave a result consistent with very heavy smoking although none had reported this degree of tobacco use. Conclusions Important discrepancies exist between subjective and objective smoking habits. Reliance on patient history may adversely affect response to tuberculosis treatment, and some patients will be denied appropriate intervention for smoking cessation.

  6. A method for the accurate determination of the polarization of a neutron beam using a polarized 3He spin filter

    International Nuclear Information System (INIS)

    Greene, G.L.; Thompson, A.K.; Dewey, M.S.

    1995-01-01

    A new method for the accurate determination of the degree of polarization of a neutron beam which has been polarized by transmission through a spin polarized 3 He cell is given. The method does not require the use of an analyzer or spin flipper nor does it require an accurate independent determination of the 3 He polarization. The method provides a continuous on-line determination of the neutron polarization. The method may be of use in the accurate determination of correlation coefficients in neutron beta decay which provide a test of the standard model for the electroweak interaction. The method may also provide an accurate procedure for the calibration of polarized 3 He targets used in medium and high energy scattering experiments. ((orig.))

  7. Assessment of the beryllium lymphocyte proliferation test using statistical process control.

    Science.gov (United States)

    Cher, Daniel J; Deubner, David C; Kelsh, Michael A; Chapman, Pamela S; Ray, Rose M

    2006-10-01

    Despite more than 20 years of surveillance and epidemiologic studies using the beryllium blood lymphocyte proliferation test (BeBLPT) as a measure of beryllium sensitization (BeS) and as an aid for diagnosing subclinical chronic beryllium disease (CBD), improvements in specific understanding of the inhalation toxicology of CBD have been limited. Although epidemiologic data suggest that BeS and CBD risks vary by process/work activity, it has proven difficult to reach specific conclusions regarding the dose-response relationship between workplace beryllium exposure and BeS or subclinical CBD. One possible reason for this uncertainty could be misclassification of BeS resulting from variation in BeBLPT testing performance. The reliability of the BeBLPT, a biological assay that measures beryllium sensitization, is unknown. To assess the performance of four laboratories that conducted this test, we used data from a medical surveillance program that offered testing for beryllium sensitization with the BeBLPT. The study population was workers exposed to beryllium at various facilities over a 10-year period (1992-2001). Workers with abnormal results were offered diagnostic workups for CBD. Our analyses used a standard statistical technique, statistical process control (SPC), to evaluate test reliability. The study design involved a repeated measures analysis of BeBLPT results generated from the company-wide, longitudinal testing. Analytical methods included use of (1) statistical process control charts that examined temporal patterns of variation for the stimulation index, a measure of cell reactivity to beryllium; (2) correlation analysis that compared prior perceptions of BeBLPT instability to the statistical measures of test variation; and (3) assessment of the variation in the proportion of missing test results and how time periods with more missing data influenced SPC findings. During the period of this study, all laboratories displayed variation in test results that

  8. Mode of Action Frameworks in Toxicity Testing and Chemical Risk Assessment

    NARCIS (Netherlands)

    Meek, B.

    2009-01-01

    Recently, legislative mandates worldwide are requiring systematic consideration of much larger numbers of chemicals. This necessitates more efficient and effective toxicity testing, as a basis to be more predictive in a risk assessment context. This in turn requires much more emphasis early in the

  9. Enhancing the Accuracy of Advanced High Temperature Mechanical Testing through Thermography

    Directory of Open Access Journals (Sweden)

    Jonathan Jones

    2018-03-01

    Full Text Available This paper describes the advantages and enhanced accuracy thermography provides to high temperature mechanical testing. This technique is not only used to monitor, but also to control test specimen temperatures where the infra-red technique enables accurate non-invasive control of rapid thermal cycling for non-metallic materials. Isothermal and dynamic waveforms are employed over a 200–800 °C temperature range to pre-oxidised and coated specimens to assess the capability of the technique. This application shows thermography to be accurate to within ±2 °C of thermocouples, a standardised measurement technique. This work demonstrates the superior visibility of test temperatures previously unobtainable by conventional thermocouples or even more modern pyrometers that thermography can deliver. As a result, the speed and accuracy of thermal profiling, thermal gradient measurements and cold/hot spot identification using the technique has increased significantly to the point where temperature can now be controlled by averaging over a specified area. The increased visibility of specimen temperatures has revealed additional unknown effects such as thermocouple shadowing, preferential crack tip heating within an induction coil, and, fundamental response time of individual measurement techniques which are investigated further.

  10. How to assess the mutagenic potential of cosmetic products without animal tests?

    Science.gov (United States)

    Speit, Günter

    2009-08-01

    Animal experiments (in vivo tests) currently play a key role in genotoxicity testing. Results from in vivo tests are, in many cases, decisive for the assessment of a mutagenic potential of a test compound. The Seventh Amendment to the European Cosmetics Directive will, however, ban the European marketing of cosmetic/personal care products that contain ingredients that have been tested in animal experiments. If genotoxicity testing is solely based on the currently established in vitro tests, the attrition rate for chemicals used in cosmetic products will greatly increase due to irrelevant positive in vitro test results. There is urgent need for new and/or improved in vitro genotoxicity tests and for modified test strategies. Test strategies should consider all available information on chemistry of the test substance/the chemical class (e.g. SAR, metabolic activation and dermal adsorption). Test protocols for in vitro genotoxicity tests should be sensitive and robust enough to ensure that negative results can be accepted with confidence. It should be excluded that positive in vitro test results are due to high cytotoxicity or secondary genotoxic effects which may be thresholded and/or only occur under in vitro test conditions. Consequently, further research is needed to establish the nature of thresholds in in vitro assays and to determine the potential for incorporation of mode of action data into future risk assessments. New/improved tests have to be established and validated, considering the use of (metabolically competent) primary (skin) cells, 3D skin models and cells with defined capacity for metabolic activation (e.g. genetically engineered cell lines). The sensitivity and specificity of new and improved genotoxicity tests has to be determined by testing a battery of genotoxic and non-genotoxic chemicals. New or adapted international guidelines will be needed for these tests. The establishment of such a new genotoxicity testing strategy will take time and the

  11. HIV testing behaviour among heterosexual migrants in Amsterdam.

    Science.gov (United States)

    Stolte, I G; Gras, M; Van Benthem, B H; Coutinho, R A; van den Hoek, J A

    2003-08-01

    This cross-sectional study among heterosexual migrant groups in south-eastern Amsterdam, the city area where the largest migrant groups live, provides an insight into HIV testing behaviour in this particular group. Participants were recruited at street locations (May 1997-July 1998) and interviewed using structured questionnaires. They also donated saliva for HIV testing. In total, 705 males and 769 females were included in this study (Afro-Surinamese (45%), Dutch-Antilleans (15%) and West Africans (40%)). Prior HIV testing was reported by 38% of all migrants (556/1479), of which only a minority (28%) had actively requested HIV testing. Multivariate logistic regression showed that not actively requesting HIV testing was more likely among younger (migrants, especially women (ORwomen: 4.79, p risk should be facilitated by promoting HIV testing and by improving accurate self-assessment of risk for HIV infection, especially among the groups that do not actively request HIV testing. This would increase HIV awareness and provide the opportunity of better medical care earlier in HIV infection.

  12. Structural integrity assessment of piping components

    International Nuclear Information System (INIS)

    Kushwaha, H.S.; Chattopadhyay, J.

    2008-01-01

    Integrity assessment of piping components is very essential for safe and reliable operation of power plants. Over the last several decades, considerable work has been done throughout the world to develop a methodology for integrity assessment of pipes and elbows, appropriate for the material involved. However, there is scope of further development/improvement of issues, particularly for pipe bends, that are important for accurate integrity assessment of piping. Considering this aspect, a comprehensive Component Integrity Test Program was initiated in 1998 at Bhabha Atomic Research Centre (BARC), India. In this program, both theoretical and experimental investigations were undertaken to address various issues related to the integrity assessment of pipes and elbows. Under the experimental investigations, fracture mechanics tests have been conducted on pipes and elbows of 200-400 mm nominal bore (NB) diameter with various crack configurations and sizes under different loading conditions. Tests on small tensile and three point bend specimens, machined from the tested pipes, have also been done to evaluate the actual stress-strain and fracture resistance properties of pipe/elbow material. The load-deflection curve and crack initiation loads predicted by non-linear finite element analysis matched well with the experimental results. The theoretical collapse moments of throughwall circumferentially cracked elbows, predicted by the recently developed equations, are found to be closer to the test data compared to the other existing equations. The role of stress triaxialities ahead of crack tip is also shown in the transferability of J-Resistance curve from specimen to component. The cyclic loading and system compliance effect on the load carrying capacity of piping components are investigated and new recommendations are made. (author)

  13. Use of Multi-Response Format Test in the Assessment of Medical Students’ Critical Thinking Ability

    Science.gov (United States)

    Mafinejad, Mahboobeh Khabaz; Monajemi, Alireza; Jalili, Mohammad; Soltani, Akbar; Rasouli, Javad

    2017-01-01

    Introduction To evaluate students critical thinking skills effectively, change in assessment practices is must. The assessment of a student’s ability to think critically is a constant challenge, and yet there is considerable debate on the best assessment method. There is evidence that the intrinsic nature of open and closed-ended response questions is to measure separate cognitive abilities. Aim To assess critical thinking ability of medical students by using multi-response format of assessment. Materials and Methods A cross-sectional study was conducted on a group of 159 undergraduate third-year medical students. All the participants completed the California Critical Thinking Skills Test (CCTST) consisting of 34 multiple-choice questions to measure general critical thinking skills and a researcher-developed test that combines open and closed-ended questions. A researcher-developed 48-question exam, consisting of 8 short-answers and 5 essay questions, 19 Multiple-Choice Questions (MCQ), and 16 True-False (TF) questions, was used to measure critical thinking skills. Correlation analyses were performed using Pearson’s coefficient to explore the association between the total scores of tests and subtests. Results One hundred and fifty-nine students participated in this study. The sample comprised 81 females (51%) and 78 males (49%) with an age range of 20±2.8 years (mean 21.2 years). The response rate was 64.1%. A significant positive correlation was found between types of questions and critical thinking scores, of which the correlations of MCQ (r=0.82) and essay questions (r=0.77) were strongest. The significant positive correlations between multi-response format test and CCTST’s subscales were seen in analysis, evaluation, inference and inductive reasoning. Unlike CCTST subscales, multi-response format test have weak correlation with CCTST total score (r=0.45, p=0.06). Conclusion This study highlights the importance of considering multi-response format test in

  14. Use of Multi-Response Format Test in the Assessment of Medical Students' Critical Thinking Ability.

    Science.gov (United States)

    Mafinejad, Mahboobeh Khabaz; Arabshahi, Seyyed Kamran Soltani; Monajemi, Alireza; Jalili, Mohammad; Soltani, Akbar; Rasouli, Javad

    2017-09-01

    To evaluate students critical thinking skills effectively, change in assessment practices is must. The assessment of a student's ability to think critically is a constant challenge, and yet there is considerable debate on the best assessment method. There is evidence that the intrinsic nature of open and closed-ended response questions is to measure separate cognitive abilities. To assess critical thinking ability of medical students by using multi-response format of assessment. A cross-sectional study was conducted on a group of 159 undergraduate third-year medical students. All the participants completed the California Critical Thinking Skills Test (CCTST) consisting of 34 multiple-choice questions to measure general critical thinking skills and a researcher-developed test that combines open and closed-ended questions. A researcher-developed 48-question exam, consisting of 8 short-answers and 5 essay questions, 19 Multiple-Choice Questions (MCQ), and 16 True-False (TF) questions, was used to measure critical thinking skills. Correlation analyses were performed using Pearson's coefficient to explore the association between the total scores of tests and subtests. One hundred and fifty-nine students participated in this study. The sample comprised 81 females (51%) and 78 males (49%) with an age range of 20±2.8 years (mean 21.2 years). The response rate was 64.1%. A significant positive correlation was found between types of questions and critical thinking scores, of which the correlations of MCQ (r=0.82) and essay questions (r=0.77) were strongest. The significant positive correlations between multi-response format test and CCTST's subscales were seen in analysis, evaluation, inference and inductive reasoning. Unlike CCTST subscales, multi-response format test have weak correlation with CCTST total score (r=0.45, p=0.06). This study highlights the importance of considering multi-response format test in the assessment of critical thinking abilities of medical

  15. Accurately tracking single-cell movement trajectories in microfluidic cell sorting devices.

    Science.gov (United States)

    Jeong, Jenny; Frohberg, Nicholas J; Zhou, Enlu; Sulchek, Todd; Qiu, Peng

    2018-01-01

    Microfluidics are routinely used to study cellular properties, including the efficient quantification of single-cell biomechanics and label-free cell sorting based on the biomechanical properties, such as elasticity, viscosity, stiffness, and adhesion. Both quantification and sorting applications require optimal design of the microfluidic devices and mathematical modeling of the interactions between cells, fluid, and the channel of the device. As a first step toward building such a mathematical model, we collected video recordings of cells moving through a ridged microfluidic channel designed to compress and redirect cells according to cell biomechanics. We developed an efficient algorithm that automatically and accurately tracked the cell trajectories in the recordings. We tested the algorithm on recordings of cells with different stiffness, and showed the correlation between cell stiffness and the tracked trajectories. Moreover, the tracking algorithm successfully picked up subtle differences of cell motion when passing through consecutive ridges. The algorithm for accurately tracking cell trajectories paves the way for future efforts of modeling the flow, forces, and dynamics of cell properties in microfluidics applications.

  16. Accurately tracking single-cell movement trajectories in microfluidic cell sorting devices.

    Directory of Open Access Journals (Sweden)

    Jenny Jeong

    Full Text Available Microfluidics are routinely used to study cellular properties, including the efficient quantification of single-cell biomechanics and label-free cell sorting based on the biomechanical properties, such as elasticity, viscosity, stiffness, and adhesion. Both quantification and sorting applications require optimal design of the microfluidic devices and mathematical modeling of the interactions between cells, fluid, and the channel of the device. As a first step toward building such a mathematical model, we collected video recordings of cells moving through a ridged microfluidic channel designed to compress and redirect cells according to cell biomechanics. We developed an efficient algorithm that automatically and accurately tracked the cell trajectories in the recordings. We tested the algorithm on recordings of cells with different stiffness, and showed the correlation between cell stiffness and the tracked trajectories. Moreover, the tracking algorithm successfully picked up subtle differences of cell motion when passing through consecutive ridges. The algorithm for accurately tracking cell trajectories paves the way for future efforts of modeling the flow, forces, and dynamics of cell properties in microfluidics applications.

  17. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    Science.gov (United States)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  18. Appropriate statistical methods are required to assess diagnostic tests for replacement, add-on, and triage

    NARCIS (Netherlands)

    Hayen, Andrew; Macaskill, Petra; Irwig, Les; Bossuyt, Patrick

    2010-01-01

    To explain which measures of accuracy and which statistical methods should be used in studies to assess the value of a new binary test as a replacement test, an add-on test, or a triage test. Selection and explanation of statistical methods, illustrated with examples. Statistical methods for

  19. Testing ESL pragmatics development and validation of a web-based assessment battery

    CERN Document Server

    Roever, Carsten

    2014-01-01

    Although second language learners' pragmatic competence (their ability to use language in context) is an essential part of their general communicative competence, it has not been a part of second language tests. This book helps fill this gap by describing the development and validation of a web-based test of ESL pragmalinguistics. The instrument assesses learners' knowledge of routine formulae, speech acts, and implicature in 36 multiple-choice and brief-response items. The test's quantitative and qualitative validation with 300 learners showed high reliability and provided strong evidence of

  20. Assessment of macrophage migration inhibitory factor in humans: protocol for accurate and reproducible levels.

    Science.gov (United States)

    Sobierajski, Julia; Hendgen-Cotta, Ulrike B; Luedike, Peter; Stock, Pia; Rammos, Christos; Meyer, Christian; Kraemer, Sandra; Stoppe, Christian; Bernhagen, Jürgen; Kelm, Malte; Rassaf, Tienush

    2013-10-01

    The analytical validation of a possible biomarker is the first step in the long translational process from basic science to clinical routine. Although the chemokine-like cytokine macrophage migration inhibitory factor (MIF) has been investigated intensively in experimental approaches to various disease conditions, its transition into clinical research is just at the very beginning. Because of its presence in preformed storage pools, MIF is the first cytokine to be released under various stimulation conditions. In the first proof-of-concept studies, MIF levels correlated with the severity and outcome of various disease states. In a recent small study with acute coronary syndrome patients, elevation of MIF was described as a new factor for risk assessment. When these studies are compared, not only MIF levels in diseased patients differ, but also MIF levels in healthy control groups are inconsistent. Blood MIF concentrations in control groups vary between 0.56 and 95.6 ng/ml, corresponding to a 170-fold difference. MIF concentrations in blood were analyzed by ELISA. Other than the influence of this approach due to method-based variations, the impact of preanalytical processing on MIF concentrations is unclear and has not been systematically studied yet. Before large randomized studies are performed to determine the impact of circulating MIF on prognosis and outcome and before MIF is characterized as a diagnostic marker, an accurate protocol for the determination of reproducible MIF levels needs to be validated. In this study, the measurement of MIF in the blood of healthy volunteers was investigated focusing on the potential influence of critical preanalytical factors such as anticoagulants, storage conditions, freeze/thaw stability, hemolysis, and dilution. We show how to avoid pitfalls in the measurement of MIF and that MIF concentrations are highly susceptible to preanalytical factors. MIF serum concentrations are higher than plasma concentrations and show broader

  1. ADIMEW: Fracture assessment and testing of an aged dissimilar metal weld pipe assembly

    International Nuclear Information System (INIS)

    Wintle, J.B.; Hayes, B.; Goldthorpe, M.R.

    2004-01-01

    ADIMEW (Assessment of Aged Piping Dissimilar Metal Weld Integrity) was a three-year collaborative research programme carried out under the EC 5th Framework Programme. The objective of the study was to advance the understanding of the behaviour and safety assessment of defects in dissimilar metal welds between pipes representative of those found in nuclear power plant. ADIMEW studied and compared different methods for predicting the behaviour of defects located near the fusion boundaries of dissimilar metal welds typically used to join sections of austenitic and ferritic piping operating at high temperature. Assessment of such defects is complicated by issues that include: severe mis-match of yield strength of the constituent parent and weld metals, strong gradients of material properties, the presence of welding residual stresses and mixed mode loading of the defect. The study includes the measurement of material properties and residual stresses, predictive engineering analysis and validation by means of a large-scale test. The particular component studied was a 453mm diameter pipe that joins a section of type A508 Class 3 ferritic pipe to a section of type 316L austenitic pipe by means of a type 308 austenitic weld with type 308/309L buttering laid on the ferritic pipe. A circumferential, surface-breaking defect was cut using electro discharge machining into the 308L/309L weld buttering layer parallel to the fusion line. The test pipe was subjected to four-point bending to promote ductile tearing of the defect. This paper presents the results of TWI contributions to ADIMEW including: fracture toughness testing, residual stress measurements and assessments of the ADIMEW test using elastic-plastic, cracked body, finite element analysis. (orig.)

  2. A novel method for objective vision testing in canine models of inherited retinal disease.

    Science.gov (United States)

    Gearhart, Patricia M; Gearhart, Chris C; Petersen-Jones, Simon M

    2008-08-01

    The use of canine models of retinal disease in the development of therapeutic strategies for inherited retinal disorders is a growing area of research. To evaluate accurately the success of potential vision-enhancing treatments, reliable methods for objectively assessing visual function in canine models is necessary. A simple vision-testing device was constructed that consisted of a junction box with four exit tunnels. Dogs were placed in the junction box and given one vision-based choice for exit. The first-choice tunnel and time to exit were recorded and analyzed. Two canine models of retinal disease with distinct molecular defects, a null mutation in the gene encoding the alpha subunit of rod cyclic GMP phosphodiesterase (PDE6A), and a null mutation in the gene encoding a retinal pigment epithelium-specific protein (RPE65) were tested and compared to those in unaffected dogs. With the use of bright light versus dim red light, the test differentiated between unaffected dogs and dogs affected with either mutation with a high degree of certainty. The white-light intensity series showed a significantly different performance between the unaffected and affected dogs. A significant difference in performance was detected between the dogs with each mutation. The results indicate that this novel canine vision-testing method is an accurate and sensitive means of distinguishing between unaffected dogs and dogs affected with two different forms of inherited retinal disease and should be useful as a means of assessing response to therapy in future studies.

  3. Accurate and Simple Calibration of DLP Projector Systems

    DEFF Research Database (Denmark)

    Wilm, Jakob; Olesen, Oline Vinter; Larsen, Rasmus

    2014-01-01

    does not rely on an initial camera calibration, and so does not carry over the error into projector calibration. A radial interpolation scheme is used to convert features coordinates into projector space, thereby allowing for a very accurate procedure. This allows for highly accurate determination...

  4. Correction of nutrition test errors for more accurate quantification of the link between dental health and malnutrition.

    Science.gov (United States)

    Dion, Nathalie; Cotart, Jean-Louis; Rabilloud, Muriel

    2007-04-01

    We quantified the link between tooth deterioration and malnutrition in institutionalized elderly subjects, taking into account the major risk factors for malnutrition and adjusting for the measurement error made in using the Mini Nutritional Assessment questionnaire. Data stem from a survey conducted in 2005 in 1094 subjects >or=60 y of age from a large sample of 100 institutions of the Rhône-Alpes region of France. A Bayesian approach was used to quantify the effect of tooth deterioration on malnutrition through a two-level logistic regression. This approach allowed taking into account the uncertainty on sensitivity and specificity of the Mini Nutritional Assessment questionnaire to adjust for the measurement error of that test. After adjustment for other risk factors, the risk of malnutrition increased significantly and continuously 1.15 times (odds ratio 1.15, 95% credibility interval 1.06-1.25) whenever the masticatory percentage decreased by 10 points, which is equivalent to the loss of two molars. The strongest factors that augmented the probability of malnutrition were deglutition disorders, depression, and verbal inconsistency. Dependency was also an important factor; the odds of malnutrition nearly doubled for each additional grade of dependency (graded 6 to 1). Diabetes, central neurodegenerative disease, and carcinoma tended to increase the probability of malnutrition but their effect was not statistically significant. Dental status should be considered a serious risk factor for malnutrition. Regular dental examination and care should preserve functional dental integrity to prevent malnutrition in institutionalized elderly people.

  5. Assessment of classroom performance of trainees in nondestructive testing (NDT) training courses

    International Nuclear Information System (INIS)

    Elauria, Erla Rhysa R.; Banaga, Renato T.; Loterina, Roel A.

    2009-01-01

    Criterion-referenced tests in an NDT course for Radiography, Level 2, are constructed and evaluated using item analysis such as item difficulty index and discrimination index. A 10-part test item was given to 37 students in a Radiography course and an item analysis of the test questions was conducted right after.The results showed that the indices of difficulty of the test items were within the desired values. Three of the test items were relatively easy questions (items 2, 3, and 4). Three of the test items were moderately difficult (items 1, 5, and 10). The discriminating indices of the items revealed acceptable values for all but a low value of 0.2 for two test items (item 2 and 10) were measured. These two items should be modified to increase their discriminating ability or eliminated. The study concluded that the said test is a reliable test with adequate discriminatory power in assessing classroom performance of NDT trainees. The study recommended that similar studies be conducted on other NDT methods like Ultrasonic Testing, Eddy Current Testing, and Surface Methods Testing. (author)

  6. Low-cost small action cameras in stereo generates accurate underwater measurements of fish

    OpenAIRE

    Letessier, T. B.; Juhel, Jean-Baptiste; Vigliola, Laurent; Meeuwig, J. J.

    2015-01-01

    Small action cameras have received interest for use in underwater videography because of their low-cost, standardised housing, widespread availability and small size. Here, we assess the capacity of GoPro action cameras to provide accurate stereo-measurements of fish in comparison to the Sony handheld cameras that have traditionally been used for this purpose. Standardised stereo-GoPro and Sony systems were employed to capture measurements of known-length targets in a pool to explore the infl...

  7. Accuracy of endoscopic intraoperative assessment of urologic stone size.

    Science.gov (United States)

    Patel, Nishant; Chew, Ben; Knudsen, Bodo; Lipkin, Michael; Wenzler, David; Sur, Roger L

    2014-05-01

    Endoscopic treatment of renal calculi relies on surgeon assessment of residual stone fragment size for either basket removal or for the passage of fragments postoperatively. We therefore sought to determine the accuracy of endoscopic assessment of renal calculi size. Between January and May 2013, five board-certified endourologists participated in an ex vivo artificial endoscopic simulation. A total of 10 stones (pebbles) were measured (mm) by nonparticipating urologist (N.D.P.) with electronic calibers and placed into separate labeled opaque test tubes to prevent visualization of the stones through the side of the tube. Endourologists were blinded to the actual size of the stones. A flexible digital ureteroscope with a 200-μm core sized laser fiber in the working channel as a size reference was placed through the ureteroscope into the test tube to estimate the stone size (mm). Accuracy was determined by obtaining the correlation coefficient (r) and constructing an Altman-Bland plot. Endourologists tended to overestimate actual stone size by a margin of 0.05 mm. The Pearson correlation coefficient was r=0.924, with a p-valuestones (stones (≥4 mm), r=0.911 vs r=0.666. Altman-bland plot analysis suggests that surgeons are able to accurately estimate stone size within a range of -1.8 to +1.9 mm. This ex vivo simulation study demonstrates that endoscopic assessment is reliable when assessing stone size. On average, there was a slight tendency to overestimate stone size by 0.05 mm. Most endourologists could visually estimate stone size within 2 mm of the actual size. These findings could be generalized to state that endourologists are accurately able to intraoperatively assess residual stone fragment size to guide decision making.

  8. Highly accurate surface maps from profilometer measurements

    Science.gov (United States)

    Medicus, Kate M.; Nelson, Jessica D.; Mandina, Mike P.

    2013-04-01

    Many aspheres and free-form optical surfaces are measured using a single line trace profilometer which is limiting because accurate 3D corrections are not possible with the single trace. We show a method to produce an accurate fully 2.5D surface height map when measuring a surface with a profilometer using only 6 traces and without expensive hardware. The 6 traces are taken at varying angular positions of the lens, rotating the part between each trace. The output height map contains low form error only, the first 36 Zernikes. The accuracy of the height map is ±10% of the actual Zernike values and within ±3% of the actual peak to valley number. The calculated Zernike values are affected by errors in the angular positioning, by the centering of the lens, and to a small effect, choices made in the processing algorithm. We have found that the angular positioning of the part should be better than 1?, which is achievable with typical hardware. The centering of the lens is essential to achieving accurate measurements. The part must be centered to within 0.5% of the diameter to achieve accurate results. This value is achievable with care, with an indicator, but the part must be edged to a clean diameter.

  9. Elastodynamic spot testing - assessing serviceability of aging elastomer parts

    International Nuclear Information System (INIS)

    Gracie, B.; Metcalfe, R.; Wensel, R.

    1995-01-01

    The properties of all polymers change with time as a function of their environment. Traditional practice has been to replace these parts according to generic time limits based on estimates of worst case material properties and conditions. This is overly-conservative in many cases, and creates unnecessary maintenance work and costs for replacement and disposal. Much of this could be avoided if the serviceability of elastomeric parts such as seals, diaphragms, gaskets, cable insulation and hoses could be reassessed on a routine basis. Elastodynamic spot testing offers a way to do this. Parts can be sampled while in service or storage to compare their as-new and used (or aged) elastodynamic properties. This data can usually be correlated with the results of functional tests to prove that material properties have not degraded to the point where the part could fail. This spot testing is similar to a micro-hardness test, but includes stress-relaxation and subsequent recovery. It provides a nondestructive means to assess the effective age of the material at a point, or several points, on a part. Sampling of hardness alone is rarely sufficient to know whether a part is still functional because this overlooks the material's viscoelastic and strength properties. An elastodynamic spot tester has been used to test different sizes, shapes and hardnesses of elastomeric parts at different levels of strain, i.e., indentation depths. An initial test program has given informative relaxation and recovery data, showing repeatability and comparing well with finite element analysis of the indentation process. Tests of aged 0-rings and diaphragms have revealed different elastodynamic properties, depending on the elastomer compound and aging conditions. (author)

  10. Prognostic durability of liver fibrosis tests and improvement in predictive performance for mortality by combining tests.

    Science.gov (United States)

    Bertrais, Sandrine; Boursier, Jérôme; Ducancelle, Alexandra; Oberti, Frédéric; Fouchard-Hubert, Isabelle; Moal, Valérie; Calès, Paul

    2017-06-01

    There is currently no recommended time interval between noninvasive fibrosis measurements for monitoring chronic liver diseases. We determined how long a single liver fibrosis evaluation may accurately predict mortality, and assessed whether combining tests improves prognostic performance. We included 1559 patients with chronic liver disease and available baseline liver stiffness measurement (LSM) by Fibroscan, aspartate aminotransferase to platelet ratio index (APRI), FIB-4, Hepascore, and FibroMeter V2G . Median follow-up was 2.8 years during which 262 (16.8%) patients died, with 115 liver-related deaths. All fibrosis tests were able to predict mortality, although APRI (and FIB-4 for liver-related mortality) showed lower overall discriminative ability than the other tests (differences in Harrell's C-index: P fibrosis, 1 year in patients with significant fibrosis, and liver disease (MELD) score testing sets. In the training set, blood tests and LSM were independent predictors of all-cause mortality. The best-fit multivariate model included age, sex, LSM, and FibroMeter V2G with C-index = 0.834 (95% confidence interval, 0.803-0.862). The prognostic model for liver-related mortality included the same covariates with C-index = 0.868 (0.831-0.902). In the testing set, the multivariate models had higher prognostic accuracy than FibroMeter V2G or LSM alone for all-cause mortality and FibroMeter V2G alone for liver-related mortality. The prognostic durability of a single baseline fibrosis evaluation depends on the liver fibrosis level. Combining LSM with a blood fibrosis test improves mortality risk assessment. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  11. MULTI-K: accurate classification of microarray subtypes using ensemble k-means clustering

    Directory of Open Access Journals (Sweden)

    Ashlock Daniel

    2009-08-01

    Full Text Available Abstract Background Uncovering subtypes of disease from microarray samples has important clinical implications such as survival time and sensitivity of individual patients to specific therapies. Unsupervised clustering methods have been used to classify this type of data. However, most existing methods focus on clusters with compact shapes and do not reflect the geometric complexity of the high dimensional microarray clusters, which limits their performance. Results We present a cluster-number-based ensemble clustering algorithm, called MULTI-K, for microarray sample classification, which demonstrates remarkable accuracy. The method amalgamates multiple k-means runs by varying the number of clusters and identifies clusters that manifest the most robust co-memberships of elements. In addition to the original algorithm, we newly devised the entropy-plot to control the separation of singletons or small clusters. MULTI-K, unlike the simple k-means or other widely used methods, was able to capture clusters with complex and high-dimensional structures accurately. MULTI-K outperformed other methods including a recently developed ensemble clustering algorithm in tests with five simulated and eight real gene-expression data sets. Conclusion The geometric complexity of clusters should be taken into account for accurate classification of microarray data, and ensemble clustering applied to the number of clusters tackles the problem very well. The C++ code and the data sets tested are available from the authors.

  12. MULTI-K: accurate classification of microarray subtypes using ensemble k-means clustering.

    Science.gov (United States)

    Kim, Eun-Youn; Kim, Seon-Young; Ashlock, Daniel; Nam, Dougu

    2009-08-22

    Uncovering subtypes of disease from microarray samples has important clinical implications such as survival time and sensitivity of individual patients to specific therapies. Unsupervised clustering methods have been used to classify this type of data. However, most existing methods focus on clusters with compact shapes and do not reflect the geometric complexity of the high dimensional microarray clusters, which limits their performance. We present a cluster-number-based ensemble clustering algorithm, called MULTI-K, for microarray sample classification, which demonstrates remarkable accuracy. The method amalgamates multiple k-means runs by varying the number of clusters and identifies clusters that manifest the most robust co-memberships of elements. In addition to the original algorithm, we newly devised the entropy-plot to control the separation of singletons or small clusters. MULTI-K, unlike the simple k-means or other widely used methods, was able to capture clusters with complex and high-dimensional structures accurately. MULTI-K outperformed other methods including a recently developed ensemble clustering algorithm in tests with five simulated and eight real gene-expression data sets. The geometric complexity of clusters should be taken into account for accurate classification of microarray data, and ensemble clustering applied to the number of clusters tackles the problem very well. The C++ code and the data sets tested are available from the authors.

  13. Accurate localization of intracavitary brachytherapy applicators from 3D CT imaging studies

    International Nuclear Information System (INIS)

    Lerma, F.A.; Williamson, J.F.

    2002-01-01

    Purpose: To present an accurate method to identify the positions and orientations of intracavitary (ICT) brachytherapy applicators imaged in 3D CT scans, in support of Monte Carlo photon-transport simulations, enabling accurate dose modeling in the presence of applicator shielding and interapplicator attenuation. Materials and methods: The method consists of finding the transformation that maximizes the coincidence between the known 3D shapes of each applicator component (colpostats and tandem) with the volume defined by contours of the corresponding surface on each CT slice. We use this technique to localize Fletcher-Suit CT-compatible applicators for three cervix cancer patients using post-implant CT examinations (3 mm slice thickness and separation). Dose distributions in 1-to-1 registration with the underlying CT anatomy are derived from 3D Monte Carlo photon-transport simulations incorporating each applicator's internal geometry (source encapsulation, high-density shields, and applicator body) oriented in relation to the dose matrix according to the measured localization transformations. The precision and accuracy of our localization method are assessed using CT scans, in which the positions and orientations of dense rods and spheres (in a precision-machined phantom) were measured at various orientations relative to the gantry. Results: Using this method, we register 3D Monte Carlo dose calculations directly onto post insertion patient CT studies. Using CT studies of a precisely machined phantom, the absolute accuracy of the method was found to be ±0.2 mm in plane, and ±0.3 mm in the axial direction while its precision was ±0.2 mm in plane, and ±0.2 mm axially. Conclusion: We have developed a novel, and accurate technique to localize intracavitary brachytherapy applicators in 3D CT imaging studies, which supports 3D dose planning involving detailed 3D Monte Carlo dose calculations, modeling source positions, shielding and interapplicator shielding

  14. Further Development of the Assessment of Military Multitasking Performance: Iterative Reliability Testing.

    Directory of Open Access Journals (Sweden)

    Margaret M Weightman

    Full Text Available The Assessment of Military Multitasking Performance (AMMP is a battery of functional dual-tasks and multitasks based on military activities that target known sensorimotor, cognitive, and exertional vulnerabilities after concussion/mild traumatic brain injury (mTBI. The AMMP was developed to help address known limitations in post concussive return to duty assessment and decision making. Once validated, the AMMP is intended for use in combination with other metrics to inform duty-readiness decisions in Active Duty Service Members following concussion. This study used an iterative process of repeated interrater reliability testing and feasibility feedback to drive modifications to the 9 tasks of the original AMMP which resulted in a final version of 6 tasks with metrics that demonstrated clinically acceptable ICCs of > 0.92 (range of 0.92-1.0 for the 3 dual tasks and > 0.87 (range 0.87-1.0 for the metrics of the 3 multitasks. Three metrics involved in recording subject errors across 2 tasks did not achieve ICCs above 0.85 set apriori for multitasks (0.64 and above 0.90 set for dual-tasks (0.77 and 0.86 and were not used for further analysis. This iterative process involved 3 phases of testing with between 13 and 26 subjects, ages 18-42 years, tested in each phase from a combined cohort of healthy controls and Service Members with mTBI. Study findings support continued validation of this assessment tool to provide rehabilitation clinicians further return to duty assessment methods robust to ceiling effects with strong face validity to injured Warriors and their leaders.

  15. Environmental assessment of general-purpose heat source safety verification testing

    International Nuclear Information System (INIS)

    1995-02-01

    This Environmental Assessment (EA) was prepared to identify and evaluate potential environmental, safety, and health impacts associated with the Proposed Action to test General-Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) assemblies at the Sandia National Laboratories (SNL) 10,000-Foot Sled Track Facility, Albuquerque, New Mexico. RTGs are used to provide a reliable source of electrical power on board some spacecraft when solar power is inadequate during long duration space missions. These units are designed to convert heat from the natural decay of radioisotope fuel into electrical power. Impact test data are required to support DOE's mission to provide radioisotope power systems to NASA and other user agencies. The proposed tests will expand the available safety database regarding RTG performance under postulated accident conditions. Direct observations and measurements of GPHS/RTG performance upon impact with hard, unyielding surfaces are required to verify model predictions and to ensure the continual evolution of the RTG designs that perform safely under varied accident environments. The Proposed Action is to conduct impact testing of RTG sections containing GPHS modules with simulated fuel. End-On and Side-On impact test series are planned

  16. Test order in teacher-rated behavior assessments: Is counterbalancing necessary?

    Science.gov (United States)

    Kooken, Janice; Welsh, Megan E; McCoach, D Betsy; Miller, Faith G; Chafouleas, Sandra M; Riley-Tillman, T Chris; Fabiano, Gregory

    2017-01-01

    Counterbalancing treatment order in experimental research design is well established as an option to reduce threats to internal validity, but in educational and psychological research, the effect of varying the order of multiple tests to a single rater has not been examined and is rarely adhered to in practice. The current study examines the effect of test order on measures of student behavior by teachers as raters utilizing data from a behavior measure validation study. Using multilevel modeling to control for students nested within teachers, the effect of rating an earlier measure on the intercept or slope of a later behavior assessment was statistically significant in 22% of predictor main effects for the spring test period. Test order effects had potential for high stakes consequences with differences large enough to change risk classification. Results suggest that researchers and practitioners in classroom settings using multiple measures evaluate the potential impact of test order. Where possible, they should counterbalance when the risk of an order effect exists and report justification for the decision to not counterbalance. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  17. Development of accurate radioactivity assessment system for radiation survey with various detectors

    International Nuclear Information System (INIS)

    Kurihara, Osamu; Kim, Eunjoo; Ueda, Junichi; Yamada, Yuji; Akashi, Makoto; Kido, Hiroko; Oguri, Tomomi; Nemoto, Shintaro; Nemoto, Makoto

    2011-01-01

    In response to requests from the sites of radiation emergency medicine, we developed a prototype of a computer system for assessing radioactive contaminants remaining in a wound or on the skin surface. This system implements numerical calibration of detectors measuring the contamination using a Monte Carlo simulation-based radiation transport code (MCNPX), coupled to a numerical phantom modeling the contaminants and the surrounding tissue. With the help of functional graphical user interfaces (GUIs) provided by the system, a user can perform desired simulations without complicated procedures to prepare input files for MCNPX. Benchmark calculations of MCNPX were conducted to verify the simulations and adjust detection-related parameter values not sufficiently provided by suppliers. The developed system should aid in making better assessments of the radiological contamination. (author)

  18. Herth hope index: psychometric testing of the Chinese version.

    Science.gov (United States)

    Chan, Keung Sum; Li, Ho Cheung William; Chan, Sally Wai-Chi; Lopez, Violeta

    2012-09-01

    This article is a report on psychometric testing of the Chinese version of the herth hope index. The availability of a valid and reliable instrument that accurately measures the level of hope in patients with heart failure is crucial before any hope-enhancing interventions can be appropriately planned and evaluated. There is no such instrument for Chinese people. A test-retest, within-subjects design was used. A purposive sample of 120 Hong Kong Chinese patients with heart failure between the ages of 60 and 80 years admitted to two medical wards was recruited during an 8-month period in 2009. Participants were asked to respond to the Chinese version of the herth hope index, Hamilton depression rating scale and Rosenberg's self-esteem scale. The internal consistency, content validity and construct validity and test-retest reliability of the Chinese version of the herth hope index were assessed. The newly translated scale demonstrated adequate internal consistency, good content validity and appropriate convergent and discriminant validity. Confirmatory factor analysis added further evidence of the construct validity of the scale. Results suggest that the newly translated scale can be used as a self-report assessment tool in assessing the level of hope in Hong Kong Chinese patients with heart failure. © 2011 Blackwell Publishing Ltd.

  19. Incorporating new technologies into toxicity testing and risk assessment: moving from 21st century vision to a data-driven framework.

    Science.gov (United States)

    Thomas, Russell S; Philbert, Martin A; Auerbach, Scott S; Wetmore, Barbara A; Devito, Michael J; Cote, Ila; Rowlands, J Craig; Whelan, Maurice P; Hays, Sean M; Andersen, Melvin E; Meek, M E Bette; Reiter, Lawrence W; Lambert, Jason C; Clewell, Harvey J; Stephens, Martin L; Zhao, Q Jay; Wesselkamper, Scott C; Flowers, Lynn; Carney, Edward W; Pastoor, Timothy P; Petersen, Dan D; Yauk, Carole L; Nong, Andy

    2013-11-01

    Based on existing data and previous work, a series of studies is proposed as a basis toward a pragmatic early step in transforming toxicity testing. These studies were assembled into a data-driven framework that invokes successive tiers of testing with margin of exposure (MOE) as the primary metric. The first tier of the framework integrates data from high-throughput in vitro assays, in vitro-to-in vivo extrapolation (IVIVE) pharmacokinetic modeling, and exposure modeling. The in vitro assays are used to separate chemicals based on their relative selectivity in interacting with biological targets and identify the concentration at which these interactions occur. The IVIVE modeling converts in vitro concentrations into external dose for calculation of the point of departure (POD) and comparisons to human exposure estimates to yield a MOE. The second tier involves short-term in vivo studies, expanded pharmacokinetic evaluations, and refined human exposure estimates. The results from the second tier studies provide more accurate estimates of the POD and the MOE. The third tier contains the traditional animal studies currently used to assess chemical safety. In each tier, the POD for selective chemicals is based primarily on endpoints associated with a proposed mode of action, whereas the POD for nonselective chemicals is based on potential biological perturbation. Based on the MOE, a significant percentage of chemicals evaluated in the first 2 tiers could be eliminated from further testing. The framework provides a risk-based and animal-sparing approach to evaluate chemical safety, drawing broadly from previous experience but incorporating technological advances to increase efficiency.

  20. Incorporating New Technologies Into Toxicity Testing and Risk Assessment: Moving From 21st Century Vision to a Data-Driven Framework

    Science.gov (United States)

    Thomas, Russell S.

    2013-01-01

    Based on existing data and previous work, a series of studies is proposed as a basis toward a pragmatic early step in transforming toxicity testing. These studies were assembled into a data-driven framework that invokes successive tiers of testing with margin of exposure (MOE) as the primary metric. The first tier of the framework integrates data from high-throughput in vitro assays, in vitro-to-in vivo extrapolation (IVIVE) pharmacokinetic modeling, and exposure modeling. The in vitro assays are used to separate chemicals based on their relative selectivity in interacting with biological targets and identify the concentration at which these interactions occur. The IVIVE modeling converts in vitro concentrations into external dose for calculation of the point of departure (POD) and comparisons to human exposure estimates to yield a MOE. The second tier involves short-term in vivo studies, expanded pharmacokinetic evaluations, and refined human exposure estimates. The results from the second tier studies provide more accurate estimates of the POD and the MOE. The third tier contains the traditional animal studies currently used to assess chemical safety. In each tier, the POD for selective chemicals is based primarily on endpoints associated with a proposed mode of action, whereas the POD for nonselective chemicals is based on potential biological perturbation. Based on the MOE, a significant percentage of chemicals evaluated in the first 2 tiers could be eliminated from further testing. The framework provides a risk-based and animal-sparing approach to evaluate chemical safety, drawing broadly from previous experience but incorporating technological advances to increase efficiency. PMID:23958734