WorldWideScience

Sample records for test intraclass correlation

  1. A comparison of two indices for the intraclass correlation coefficient.

    Science.gov (United States)

    Shieh, Gwowen

    2012-12-01

    In the present study, we examined the behavior of two indices for measuring the intraclass correlation in the one-way random effects model: the prevailing ICC(1) (Fisher, 1938) and the corrected eta-squared (Bliese & Halverson, 1998). These two procedures differ both in their methods of estimating the variance components that define the intraclass correlation coefficient and in their performance of bias and mean squared error in the estimation of the intraclass correlation coefficient. In contrast with the natural unbiased principle used to construct ICC(1), in the present study it was analytically shown that the corrected eta-squared estimator is identical to the maximum likelihood estimator and the pairwise estimator under equal group sizes. Moreover, the empirical results obtained from the present Monte Carlo simulation study across various group structures revealed the mutual dominance relationship between their truncated versions for negative values. The corrected eta-squared estimator performs better than the ICC(1) estimator when the underlying population intraclass correlation coefficient is small. Conversely, ICC(1) has a clear advantage over the corrected eta-squared for medium and large magnitudes of population intraclass correlation coefficient. The conceptual description and numerical investigation provide guidelines to help researchers choose between the two indices for more accurate reliability analysis in multilevel research.

  2. Estimating a graphical intra-class correlation coefficient (GICC) using multivariate probit-linear mixed models.

    Science.gov (United States)

    Yue, Chen; Chen, Shaojie; Sair, Haris I; Airan, Raag; Caffo, Brian S

    2015-09-01

    Data reproducibility is a critical issue in all scientific experiments. In this manuscript, the problem of quantifying the reproducibility of graphical measurements is considered. The image intra-class correlation coefficient (I2C2) is generalized and the graphical intra-class correlation coefficient (GICC) is proposed for such purpose. The concept for GICC is based on multivariate probit-linear mixed effect models. A Markov Chain Monte Carlo EM (mcm-cEM) algorithm is used for estimating the GICC. Simulation results with varied settings are demonstrated and our method is applied to the KIRBY21 test-retest dataset.

  3. Exact Distributions of Intraclass Correlation and Cronbach's Alpha with Gaussian Data and General Covariance

    Science.gov (United States)

    Kistner, Emily O.; Muller, Keith E.

    2004-01-01

    Intraclass correlation and Cronbach's alpha are widely used to describe reliability of tests and measurements. Even with Gaussian data, exact distributions are known only for compound symmetric covariance (equal variances and equal correlations). Recently, large sample Gaussian approximations were derived for the distribution functions. New exact…

  4. Choosing the best index for the average score intraclass correlation coefficient.

    Science.gov (United States)

    Shieh, Gwowen

    2016-09-01

    The intraclass correlation coefficient (ICC)(2) index from a one-way random effects model is widely used to describe the reliability of mean ratings in behavioral, educational, and psychological research. Despite its apparent utility, the essential property of ICC(2) as a point estimator of the average score intraclass correlation coefficient is seldom mentioned. This article considers several potential measures and compares their performance with ICC(2). Analytical derivations and numerical examinations are presented to assess the bias and mean square error of the alternative estimators. The results suggest that more advantageous indices can be recommended over ICC(2) for their theoretical implication and computational ease.

  5. A comparison of confidence interval methods for the intraclass correlation coefficient in community-based cluster randomization trials with a binary outcome.

    Science.gov (United States)

    Braschel, Melissa C; Svec, Ivana; Darlington, Gerarda A; Donner, Allan

    2016-04-01

    Many investigators rely on previously published point estimates of the intraclass correlation coefficient rather than on their associated confidence intervals to determine the required size of a newly planned cluster randomized trial. Although confidence interval methods for the intraclass correlation coefficient that can be applied to community-based trials have been developed for a continuous outcome variable, fewer methods exist for a binary outcome variable. The aim of this study is to evaluate confidence interval methods for the intraclass correlation coefficient applied to binary outcomes in community intervention trials enrolling a small number of large clusters. Existing methods for confidence interval construction are examined and compared to a new ad hoc approach based on dividing clusters into a large number of smaller sub-clusters and subsequently applying existing methods to the resulting data. Monte Carlo simulation is used to assess the width and coverage of confidence intervals for the intraclass correlation coefficient based on Smith's large sample approximation of the standard error of the one-way analysis of variance estimator, an inverted modified Wald test for the Fleiss-Cuzick estimator, and intervals constructed using a bootstrap-t applied to a variance-stabilizing transformation of the intraclass correlation coefficient estimate. In addition, a new approach is applied in which clusters are randomly divided into a large number of smaller sub-clusters with the same methods applied to these data (with the exception of the bootstrap-t interval, which assumes large cluster sizes). These methods are also applied to a cluster randomized trial on adolescent tobacco use for illustration. When applied to a binary outcome variable in a small number of large clusters, existing confidence interval methods for the intraclass correlation coefficient provide poor coverage. However, confidence intervals constructed using the new approach combined with Smith

  6. Pitfalls and important issues in testing reliability using intraclass correlation coefficients in orthopaedic research.

    Science.gov (United States)

    Lee, Kyoung Min; Lee, Jaebong; Chung, Chin Youb; Ahn, Soyeon; Sung, Ki Hyuk; Kim, Tae Won; Lee, Hui Jong; Park, Moon Seok

    2012-06-01

    Intra-class correlation coefficients (ICCs) provide a statistical means of testing the reliability. However, their interpretation is not well documented in the orthopedic field. The purpose of this study was to investigate the use of ICCs in the orthopedic literature and to demonstrate pitfalls regarding their use. First, orthopedic articles that used ICCs were retrieved from the Pubmed database, and journal demography, ICC models and concurrent statistics used were evaluated. Second, reliability test was performed on three common physical examinations in cerebral palsy, namely, the Thomas test, the Staheli test, and popliteal angle measurement. Thirty patients were assessed by three orthopedic surgeons to explore the statistical methods testing reliability. Third, the factors affecting the ICC values were examined by simulating the data sets based on the physical examination data where the ranges, slopes, and interobserver variability were modified. Of the 92 orthopedic articles identified, 58 articles (63%) did not clarify the ICC model used, and only 5 articles (5%) described all models, types, and measures. In reliability testing, although the popliteal angle showed a larger mean absolute difference than the Thomas test and the Staheli test, the ICC of popliteal angle was higher, which was believed to be contrary to the context of measurement. In addition, the ICC values were affected by the model, type, and measures used. In simulated data sets, the ICC showed higher values when the range of data sets were larger, the slopes of the data sets were parallel, and the interobserver variability was smaller. Care should be taken when interpreting the absolute ICC values, i.e., a higher ICC does not necessarily mean less variability because the ICC values can also be affected by various factors. The authors recommend that researchers clarify ICC models used and ICC values are interpreted in the context of measurement.

  7. Intraclass Correlation Coefficients in Hierarchical Designs: Evaluation Using Latent Variable Modeling

    Science.gov (United States)

    Raykov, Tenko

    2011-01-01

    Interval estimation of intraclass correlation coefficients in hierarchical designs is discussed within a latent variable modeling framework. A method accomplishing this aim is outlined, which is applicable in two-level studies where participants (or generally lower-order units) are clustered within higher-order units. The procedure can also be…

  8. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

    Science.gov (United States)

    Koo, Terry K; Li, Mae Y

    2016-06-01

    Intraclass correlation coefficient (ICC) is a widely used reliability index in test-retest, intrarater, and interrater reliability analyses. This article introduces the basic concept of ICC in the content of reliability analysis. There are 10 forms of ICCs. Because each form involves distinct assumptions in their calculation and will lead to different interpretations, researchers should explicitly specify the ICC form they used in their calculation. A thorough review of the research design is needed in selecting the appropriate form of ICC to evaluate reliability. The best practice of reporting ICC should include software information, "model," "type," and "definition" selections. When coming across an article that includes ICC, readers should first check whether information about the ICC form has been reported and if an appropriate ICC form was used. Based on the 95% confident interval of the ICC estimate, values less than 0.5, between 0.5 and 0.75, between 0.75 and 0.9, and greater than 0.90 are indicative of poor, moderate, good, and excellent reliability, respectively. This article provides a practical guideline for clinical researchers to choose the correct form of ICC and suggests the best practice of reporting ICC parameters in scientific publications. This article also gives readers an appreciation for what to look for when coming across ICC while reading an article.

  9. Intraclass Correlation Coefficients in Hierarchical Design Studies with Discrete Response Variables: A Note on a Direct Interval Estimation Procedure

    Science.gov (United States)

    Raykov, Tenko; Marcoulides, George A.

    2015-01-01

    A latent variable modeling procedure that can be used to evaluate intraclass correlation coefficients in two-level settings with discrete response variables is discussed. The approach is readily applied when the purpose is to furnish confidence intervals at prespecified confidence levels for these coefficients in setups with binary or ordinal…

  10. The intraclass correlation coefficient applied for evaluation of data correction, labeling methods and rectal biopsy sampling in DNA microarray experiments

    NARCIS (Netherlands)

    Pellis, E.P.M.; Franssen-Hal, van N.L.W.; Burema, J.; Keijer, J.

    2003-01-01

    We show that the intraclass correlation coefficient (ICC) can be used as a relatively simple statistical measure to assess methodological and biological variation in DNA microarray analysis. The ICC is a measure that determines the reproducibility of a variable, which can easily be calculated from

  11. Intraclass correlation values for adolescent health outcomes in secondary schools in 21 European countries

    Directory of Open Access Journals (Sweden)

    N. Shackleton

    2016-12-01

    Full Text Available Background: Cluster randomised controlled trials (CRCTs are increasingly used to evaluate the effectiveness of interventions for improving health. A key feature of CRCTs is that individuals in clusters are often more alike than individuals in different clusters, irrespective of treatment. This similarity within clusters needs to be taken into account when planning CRCTs to obtain adequate sample sizes, and when analysing clustered data to obtain correct estimates. Methods: Nationally representative data from 15 to 16 year olds were analysed, from 21 of the 35 countries that participated in the 2007 European School Survey Project on Alcohol and Other Drugs. Within country school level intra-class correlation coefficients (ICCs were calculated for substance use (self-reported alcohol use, regular alcohol use, binge drinking, any smoking, regular smoking, and illicit drug use and psychosocial health (depressive mood and self-esteem. Unadjusted and adjusted ICCs are presented. ICCs are adjusted for student sex and socioeconomic status. Results: ICCs ranged from 0.01 to 0.21, with the highest (0.21 reported for regular smoking. Within country school level ICCs varied substantially across health outcomes, and among countries for the same health outcomes. Estimated ICCs were consistently higher for substance use (range 0.01–0.21, than for psychosocial health (range 0.01–0.07. Within country ICCs for health outcomes varied by changes in the measurement of particular health outcomes, for example the ICCs for regular smoking (range 0.06–0.21 were higher than those for having smoked at all in the last month (range 0.03–0.17. Conclusions: For school level ICCs to be effectively utilised in informing sample size requirements for CRCTs and adjusting estimates from meta-analyses, the school level ICCs need to be both country and outcome specific. Keywords: Intra-class correlation, Schools, Adolescents, Substance use, Mental health

  12. Reliability of environmental sampling culture results using the negative binomial intraclass correlation coefficient.

    Science.gov (United States)

    Aly, Sharif S; Zhao, Jianyang; Li, Ben; Jiang, Jiming

    2014-01-01

    The Intraclass Correlation Coefficient (ICC) is commonly used to estimate the similarity between quantitative measures obtained from different sources. Overdispersed data is traditionally transformed so that linear mixed model (LMM) based ICC can be estimated. A common transformation used is the natural logarithm. The reliability of environmental sampling of fecal slurry on freestall pens has been estimated for Mycobacterium avium subsp. paratuberculosis using the natural logarithm transformed culture results. Recently, the negative binomial ICC was defined based on a generalized linear mixed model for negative binomial distributed data. The current study reports on the negative binomial ICC estimate which includes fixed effects using culture results of environmental samples. Simulations using a wide variety of inputs and negative binomial distribution parameters (r; p) showed better performance of the new negative binomial ICC compared to the ICC based on LMM even when negative binomial data was logarithm, and square root transformed. A second comparison that targeted a wider range of ICC values showed that the mean of estimated ICC closely approximated the true ICC.

  13. Intra-class correlation estimates for assessment of vitamin A intake in children.

    Science.gov (United States)

    Agarwal, Girdhar G; Awasthi, Shally; Walter, Stephen D

    2005-03-01

    In many community-based surveys, multi-level sampling is inherent in the design. In the design of these studies, especially to calculate the appropriate sample size, investigators need good estimates of intra-class correlation coefficient (ICC), along with the cluster size, to adjust for variation inflation due to clustering at each level. The present study used data on the assessment of clinical vitamin A deficiency and intake of vitamin A-rich food in children in a district in India. For the survey, 16 households were sampled from 200 villages nested within eight randomly-selected blocks of the district. ICCs and components of variances were estimated from a three-level hierarchical random effects analysis of variance model. Estimates of ICCs and variance components were obtained at village and block levels. Between-cluster variation was evident at each level of clustering. In these estimates, ICCs were inversely related to cluster size, but the design effect could be substantial for large clusters. At the block level, most ICC estimates were below 0.07. At the village level, many ICC estimates ranged from 0.014 to 0.45. These estimates may provide useful information for the design of epidemiological studies in which the sampled (or allocated) units range in size from households to large administrative zones.

  14. The Children's Global Assessment Scale (CGAS) and Global Assessment of Psychosocial Disability (GAPD) in clinical practice--substance and reliability as judged by intraclass correlations

    DEFF Research Database (Denmark)

    Dyrborg, J; Larsen, F W; Nielsen, S

    2000-01-01

    Studies on the inter-rater reliability on the Children's Global Assessment Scale (CGAS) and the Global Assessment of Psychosocial Disability (GAPD) involving different subgroups of 145 outpatients from 4 to 16 years of age showed fair to substantial intraclass correlations of 0.59 to 0.90. Raters...

  15. Complex versus Simple Modeling for DIF Detection: When the Intraclass Correlation Coefficient (?) of the Studied Item Is Less Than the ? of the Total Score

    Science.gov (United States)

    Jin, Ying; Myers, Nicholas D.; Ahn, Soyeon

    2014-01-01

    Previous research has demonstrated that differential item functioning (DIF) methods that do not account for multilevel data structure could result in too frequent rejection of the null hypothesis (i.e., no DIF) when the intraclass correlation coefficient (?) of the studied item was the same as the ? of the total score. The current study extended…

  16. Understanding Intra-Class Knowledge Inside CNN

    OpenAIRE

    Wei, Donglai; Zhou, Bolei; Torrabla, Antonio; Freeman, William

    2015-01-01

    Convolutional Neural Network (CNN) has been successful in image recognition tasks, and recent works shed lights on how CNN separates different classes with the learned inter-class knowledge through visualization. In this work, we instead visualize the intra-class knowledge inside CNN to better understand how an object class is represented in the fully-connected layers. To invert the intra-class knowledge into more interpretable images, we propose a non-parametric patch prior upon previous CNN...

  17. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    Science.gov (United States)

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  18. Context-sensitive intra-class clustering

    KAUST Repository

    Yu, Yingwei; Gutierrez-Osuna, Ricardo; Choe, Yoonsuck

    2014-01-01

    This paper describes a new semi-supervised learning algorithm for intra-class clustering (ICC). ICC partitions each class into sub-classes in order to minimize overlap across clusters from different classes. This is achieved by allowing partitioning

  19. Tutorial on use of intraclass correlation coefficients for assessing intertest reliability and its application in functional near-infrared spectroscopy-based brain imaging.

    Science.gov (United States)

    Li, Lin; Zeng, Li; Lin, Zi-Jing; Cazzell, Mary; Liu, Hanli

    2015-05-01

    Test-retest reliability of neuroimaging measurements is an important concern in the investigation of cognitive functions in the human brain. To date, intraclass correlation coefficients (ICCs), originally used in interrater reliability studies in behavioral sciences, have become commonly used metrics in reliability studies on neuroimaging and functional near-infrared spectroscopy (fNIRS). However, as there are six popular forms of ICC, the adequateness of the comprehensive understanding of ICCs will affect how one may appropriately select, use, and interpret ICCs toward a reliability study. We first offer a brief review and tutorial on the statistical rationale of ICCs, including their underlying analysis of variance models and technical definitions, in the context of assessment on intertest reliability. Second, we provide general guidelines on the selection and interpretation of ICCs. Third, we illustrate the proposed approach by using an actual research study to assess interest reliability of fNIRS-based, volumetric diffuse optical tomography of brain activities stimulated by a risk decision-making protocol. Last, special issues that may arise in reliability assessment using ICCs are discussed and solutions are suggested.

  20. Tutorial on use of intraclass correlation coefficients for assessing intertest reliability and its application in functional near-infrared spectroscopy-based brain imaging

    Science.gov (United States)

    Li, Lin; Zeng, Li; Lin, Zi-Jing; Cazzell, Mary; Liu, Hanli

    2015-05-01

    Test-retest reliability of neuroimaging measurements is an important concern in the investigation of cognitive functions in the human brain. To date, intraclass correlation coefficients (ICCs), originally used in inter-rater reliability studies in behavioral sciences, have become commonly used metrics in reliability studies on neuroimaging and functional near-infrared spectroscopy (fNIRS). However, as there are six popular forms of ICC, the adequateness of the comprehensive understanding of ICCs will affect how one may appropriately select, use, and interpret ICCs toward a reliability study. We first offer a brief review and tutorial on the statistical rationale of ICCs, including their underlying analysis of variance models and technical definitions, in the context of assessment on intertest reliability. Second, we provide general guidelines on the selection and interpretation of ICCs. Third, we illustrate the proposed approach by using an actual research study to assess intertest reliability of fNIRS-based, volumetric diffuse optical tomography of brain activities stimulated by a risk decision-making protocol. Last, special issues that may arise in reliability assessment using ICCs are discussed and solutions are suggested.

  1. Intraclass reliability of the Alberta Infant Motor Scale in the Brazilian version

    Directory of Open Access Journals (Sweden)

    Larissa Paiva Silva

    2013-10-01

    Full Text Available This study had as its objective to analyze the intraclass reliability of the Alberta Infant Motor Scale (AIMS, in the Brazilian version, in preterm and term infants. It was a methodological study, conducted from November 2009 to April 2010, with 50 children receiving care in two public institutions in Fortaleza, Ceará, Brazil. Children were grouped according to gestational age as preterm and term, and evaluated by three evaluators in the communication laboratory of a public institution or at home. The intraclass correlation indices for the categories prone, supine, sitting and standing ranged from 0.553 to 0.952; most remained above 0.800, except for the standing category of the third evaluator, in which the index was 0.553. As for the total score and percentile, rates ranged from 0.843 to 0.954. The scale proved to be a reliable instrument for assessing gross motor performance of Brazilian children, particularly in Ceará, regardless of gestational age at birth.

  2. A comparison of confidence interval methods for the concordance correlation coefficient and intraclass correlation coefficient with small number of raters.

    Science.gov (United States)

    Feng, Dai; Svetnik, Vladimir; Coimbra, Alexandre; Baumgartner, Richard

    2014-01-01

    The intraclass correlation coefficient (ICC) with fixed raters or, equivalently, the concordance correlation coefficient (CCC) for continuous outcomes is a widely accepted aggregate index of agreement in settings with small number of raters. Quantifying the precision of the CCC by constructing its confidence interval (CI) is important in early drug development applications, in particular in qualification of biomarker platforms. In recent years, there have been several new methods proposed for construction of CIs for the CCC, but their comprehensive comparison has not been attempted. The methods consisted of the delta method and jackknifing with and without Fisher's Z-transformation, respectively, and Bayesian methods with vague priors. In this study, we carried out a simulation study, with data simulated from multivariate normal as well as heavier tailed distribution (t-distribution with 5 degrees of freedom), to compare the state-of-the-art methods for assigning CI to the CCC. When the data are normally distributed, the jackknifing with Fisher's Z-transformation (JZ) tended to provide superior coverage and the difference between it and the closest competitor, the Bayesian method with the Jeffreys prior was in general minimal. For the nonnormal data, the jackknife methods, especially the JZ method, provided the coverage probabilities closest to the nominal in contrast to the others which yielded overly liberal coverage. Approaches based upon the delta method and Bayesian method with conjugate prior generally provided slightly narrower intervals and larger lower bounds than others, though this was offset by their poor coverage. Finally, we illustrated the utility of the CIs for the CCC in an example of a wake after sleep onset (WASO) biomarker, which is frequently used in clinical sleep studies of drugs for treatment of insomnia.

  3. MIDAS and HIT-6 French translation: reliability and correlation between tests.

    Science.gov (United States)

    Magnoux, E; Freeman, M A; Zlotnik, G

    2008-01-01

    , with a median of 19 days. The Shrout-Fleiss intraclass correlation coefficients for MIDAS and HIT-6 were, respectively, 0.76 and 0.77 for episodic headaches and 0.83 and 0.80 for chronic headaches. The Pearson correlation coefficient between the MIDAS and HIT-6 questionnaires was 0.48 for episodic headaches and 0.58 for chronic headaches at the first compilation and 0.42 and 0.59 at the second compilation. The test-retest intraclass correlation of the French versions for both MIDAS and HIT-6 questionnaires indicates moderate reliability for episodic headache and substantial reliability for chronic headache. The correlation between the MIDAS and HIT-6 questionnaires is weak for episodic headaches, but approaches a level of 'good' for chronic headaches.

  4. Performance of intraclass correlation coefficient (ICC) as a reliability index under various distributions in scale reliability studies.

    Science.gov (United States)

    Mehta, Shraddha; Bastero-Caballero, Rowena F; Sun, Yijun; Zhu, Ray; Murphy, Diane K; Hardas, Bhushan; Koch, Gary

    2018-04-29

    Many published scale validation studies determine inter-rater reliability using the intra-class correlation coefficient (ICC). However, the use of this statistic must consider its advantages, limitations, and applicability. This paper evaluates how interaction of subject distribution, sample size, and levels of rater disagreement affects ICC and provides an approach for obtaining relevant ICC estimates under suboptimal conditions. Simulation results suggest that for a fixed number of subjects, ICC from the convex distribution is smaller than ICC for the uniform distribution, which in turn is smaller than ICC for the concave distribution. The variance component estimates also show that the dissimilarity of ICC among distributions is attributed to the study design (ie, distribution of subjects) component of subject variability and not the scale quality component of rater error variability. The dependency of ICC on the distribution of subjects makes it difficult to compare results across reliability studies. Hence, it is proposed that reliability studies should be designed using a uniform distribution of subjects because of the standardization it provides for representing objective disagreement. In the absence of uniform distribution, a sampling method is proposed to reduce the non-uniformity. In addition, as expected, high levels of disagreement result in low ICC, and when the type of distribution is fixed, any increase in the number of subjects beyond a moderately large specification such as n = 80 does not have a major impact on ICC. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  6. The coefficient of determination R2 and intra-class correlation coefficient from generalized linear mixed-effects models revisited and expanded.

    Science.gov (United States)

    Nakagawa, Shinichi; Johnson, Paul C D; Schielzeth, Holger

    2017-09-01

    The coefficient of determination R 2 quantifies the proportion of variance explained by a statistical model and is an important summary statistic of biological interest. However, estimating R 2 for generalized linear mixed models (GLMMs) remains challenging. We have previously introduced a version of R 2 that we called [Formula: see text] for Poisson and binomial GLMMs, but not for other distributional families. Similarly, we earlier discussed how to estimate intra-class correlation coefficients (ICCs) using Poisson and binomial GLMMs. In this paper, we generalize our methods to all other non-Gaussian distributions, in particular to negative binomial and gamma distributions that are commonly used for modelling biological data. While expanding our approach, we highlight two useful concepts for biologists, Jensen's inequality and the delta method, both of which help us in understanding the properties of GLMMs. Jensen's inequality has important implications for biologically meaningful interpretation of GLMMs, whereas the delta method allows a general derivation of variance associated with non-Gaussian distributions. We also discuss some special considerations for binomial GLMMs with binary or proportion data. We illustrate the implementation of our extension by worked examples from the field of ecology and evolution in the R environment. However, our method can be used across disciplines and regardless of statistical environments. © 2017 The Author(s).

  7. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    Science.gov (United States)

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  8. The relationship between multilevel models and non-parametric multilevel mixture models: Discrete approximation of intraclass correlation, random coefficient distributions, and residual heteroscedasticity.

    Science.gov (United States)

    Rights, Jason D; Sterba, Sonya K

    2016-11-01

    Multilevel data structures are common in the social sciences. Often, such nested data are analysed with multilevel models (MLMs) in which heterogeneity between clusters is modelled by continuously distributed random intercepts and/or slopes. Alternatively, the non-parametric multilevel regression mixture model (NPMM) can accommodate the same nested data structures through discrete latent class variation. The purpose of this article is to delineate analytic relationships between NPMM and MLM parameters that are useful for understanding the indirect interpretation of the NPMM as a non-parametric approximation of the MLM, with relaxed distributional assumptions. We define how seven standard and non-standard MLM specifications can be indirectly approximated by particular NPMM specifications. We provide formulas showing how the NPMM can serve as an approximation of the MLM in terms of intraclass correlation, random coefficient means and (co)variances, heteroscedasticity of residuals at level 1, and heteroscedasticity of residuals at level 2. Further, we discuss how these relationships can be useful in practice. The specific relationships are illustrated with simulated graphical demonstrations, and direct and indirect interpretations of NPMM classes are contrasted. We provide an R function to aid in implementing and visualizing an indirect interpretation of NPMM classes. An empirical example is presented and future directions are discussed. © 2016 The British Psychological Society.

  9. Intraclass Correlation Coefficients for Obesity Indicators and Energy Balance-Related Behaviors Among New York City Public Elementary Schools.

    Science.gov (United States)

    Gray, Heewon Lee; Burgermaster, Marissa; Tipton, Elizabeth; Contento, Isobel R; Koch, Pamela A; Di Noia, Jennifer

    2016-04-01

    Sample size and statistical power calculation should consider clustering effects when schools are the unit of randomization in intervention studies. The objective of the current study was to investigate how student outcomes are clustered within schools in an obesity prevention trial. Baseline data from the Food, Health & Choices project were used. Participants were 9- to 13-year-old students enrolled in 20 New York City public schools (n= 1,387). Body mass index (BMI) was calculated based on measures of height and weight, and body fat percentage was measured with a Tanita® body composition analyzer (Model SC-331s). Energy balance-related behaviors were self-reported with a frequency questionnaire. To examine the cluster effects, intraclass correlation coefficients (ICCs) were calculated as school variance over total variance for outcome variables. School-level covariates, percentage students eligible for free and reduced-price lunch, percentage Black or Hispanic, and English language learners were added in the model to examine ICC changes. The ICCs for obesity indicators are: .026 for BMI-percentile, .031 for BMIz-score, .035 for percentage of overweight students, .037 for body fat percentage, and .041 for absolute BMI. The ICC range for the six energy balance-related behaviors are .008 to .044 for fruit and vegetables, .013 to .055 for physical activity, .031 to .052 for recreational screen time, .013 to .091 for sweetened beverages, .033 to .121 for processed packaged snacks, and .020 to .083 for fast food. When school-level covariates were included in the model, ICC changes varied from -95% to 85%. This is the first study reporting ICCs for obesity-related anthropometric and behavioral outcomes among New York City public schools. The results of the study may aid sample size estimation for future school-based cluster randomized controlled trials in similar urban setting and population. Additionally, identifying school-level covariates that can reduce cluster

  10. Context-sensitive intra-class clustering

    KAUST Repository

    Yu, Yingwei

    2014-02-01

    This paper describes a new semi-supervised learning algorithm for intra-class clustering (ICC). ICC partitions each class into sub-classes in order to minimize overlap across clusters from different classes. This is achieved by allowing partitioning of a certain class to be assisted by data points from other classes in a context-dependent fashion. The result is that overlap across sub-classes (both within- and across class) is greatly reduced. ICC is particularly useful when combined with algorithms that assume that each class has a unimodal Gaussian distribution (e.g., Linear Discriminant Analysis (LDA), quadratic classifiers), an assumption that is not always true in many real-world situations. ICC can help partition non-Gaussian, multimodal distributions to overcome such a problem. In this sense, ICC works as a preprocessor. Experiments with our ICC algorithm on synthetic data sets and real-world data sets indicated that it can significantly improve the performance of LDA and quadratic classifiers. We expect our approach to be applicable to a broader class of pattern recognition problems where class-conditional densities are significantly non-Gaussian or multi-modal. © 2013 Elsevier Ltd. All rights reserved.

  11. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    Science.gov (United States)

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which

  12. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    Science.gov (United States)

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  13. Older women with dementia can perform fast alternating forearm movements and performance is correlated with tests of lower extremity function

    Directory of Open Access Journals (Sweden)

    Bramell-Risberg E

    2013-02-01

    Full Text Available Eva Bramell-Risberg,1 Gun-Britt Jarnlo,2 Sölve Elmståhl11Division of Geriatric Medicine, 2Division of Physiotherapy, Department of Health Sciences, Lund University, Lund, SwedenBackground: The purpose of this work was to study the performance and reliability of a test of fast alternating forearm movements and its relationship with measures of lower extremity function in older women with dementia.Methods: Fast alternating movements was studied in 26 female patients (mean age 81.7 ± 5.9 years with dementia and 34 controls (mean age 87.5 ± 4.7 years. Subgroup analyses for those aged 80–89 years were performed due to significant differences in the mean ages of the study groups. Test–retest reliability for alternating forearm movements was studied in 11 patients (mean age 80.3 ± 6.7 years and 10 controls (mean age 87.4 ± 1.6 years. Pulses generated were transformed to an analog signal shown on a modified electrocardiogram. Numbers of cycles at 10 and 15 seconds were calculated for the right and left hand. Walking 2 × 15 m and the Get-Up-and Go (GUG test were performed at self-selected and maximal speed. Associations between tests of upper and lower extremity function were sought in eight patients (mean age 85 ± 2.7 years and 16 controls (mean age 85.1 ± 2.8 years and also according to types of dementia in nine patients with probable Alzheimer's disease and 10 patients with other types of dementia.Results: Patients with dementia could perform the test and had significantly fewer cycles (P = 0.02–0.006 at both 10 and 15 seconds compared with controls after age adjustment. A higher number of cycles was associated with higher self-selected walking speeds in patients (r = -0.79. Test–retest reliability for alternating forearm movements was high for both patients (intraclass correlation 0.88–0.94 and controls (intraclass correlation 0.74–0.94.Conclusion: Alternating forearm movements at fast speed can be used as a reliable test in both

  14. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    Science.gov (United States)

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  15. A default Bayesian hypothesis test for correlations and partial correlations

    NARCIS (Netherlands)

    Wetzels, R.; Wagenmakers, E.J.

    2012-01-01

    We propose a default Bayesian hypothesis test for the presence of a correlation or a partial correlation. The test is a direct application of Bayesian techniques for variable selection in regression models. The test is easy to apply and yields practical advantages that the standard frequentist tests

  16. Testing Cross-Sectional Correlation in Large Panel Data Models with Serial Correlation

    Directory of Open Access Journals (Sweden)

    Badi H. Baltagi

    2016-11-01

    Full Text Available This paper considers the problem of testing cross-sectional correlation in large panel data models with serially-correlated errors. It finds that existing tests for cross-sectional correlation encounter size distortions with serial correlation in the errors. To control the size, this paper proposes a modification of Pesaran’s Cross-sectional Dependence (CD test to account for serial correlation of an unknown form in the error term. We derive the limiting distribution of this test as N , T → ∞ . The test is distribution free and allows for unknown forms of serial correlation in the errors. Monte Carlo simulations show that the test has good size and power for large panels when serial correlation in the errors is present.

  17. Testing power-law cross-correlations: Rescaled covariance test

    Czech Academy of Sciences Publication Activity Database

    Krištoufek, Ladislav

    2013-01-01

    Roč. 86, č. 10 (2013), 418-1-418-15 ISSN 1434-6028 R&D Projects: GA ČR GA402/09/0965 Institutional support: RVO:67985556 Keywords : power-law cross-correlations * testing * long-term memory Subject RIV: AH - Economics Impact factor: 1.463, year: 2013 http://library.utia.cas.cz/separaty/2013/E/kristoufek-testing power-law cross-correlations rescaled covariance test.pdf

  18. Dynamic control of the lumbopelvic complex; lack of reliability of established test procedures

    DEFF Research Database (Denmark)

    Henriksen, Marius; Lund, Hans; Bliddal, Henning

    2007-01-01

    used in order to account for learning effects. Intraclass correlation coefficients were low for the sitting (0.54) and supported standing positions (0.36). In the standing position, a significant difference between test and retest was observed (P = 0.003) and further reliability analysis was therefore...

  19. Meaningful Effect Sizes, Intraclass Correlations, and Proportions of Variance Explained by Covariates for Planning Two- and Three-Level Cluster Randomized Trials of Social and Behavioral Outcomes.

    Science.gov (United States)

    Dong, Nianbo; Reinke, Wendy M; Herman, Keith C; Bradshaw, Catherine P; Murray, Desiree W

    2016-09-30

    There is a need for greater guidance regarding design parameters and empirical benchmarks for social and behavioral outcomes to inform assumptions in the design and interpretation of cluster randomized trials (CRTs). We calculated the empirical reference values on critical research design parameters associated with statistical power for children's social and behavioral outcomes, including effect sizes, intraclass correlations (ICCs), and proportions of variance explained by a covariate at different levels (R 2 ). Children from kindergarten to Grade 5 in the samples from four large CRTs evaluating the effectiveness of two classroom- and two school-level preventive interventions. Teacher ratings of students' social and behavioral outcomes using the Teacher Observation of Classroom Adaptation-Checklist and the Social Competence Scale-Teacher. Two types of effect size benchmarks were calculated: (1) normative expectations for change and (2) policy-relevant demographic performance gaps. The ICCs and R 2 were calculated using two-level hierarchical linear modeling (HLM), where students are nested within schools, and three-level HLM, where students were nested within classrooms, and classrooms were nested within schools. Comprehensive tables of benchmarks and ICC values are provided to inform prevention researchers in interpreting the effect size of interventions and conduct power analyses for designing CRTs of children's social and behavioral outcomes. The discussion also provides a demonstration for how to use the parameter reference values provided in this article to calculate the sample size for two- and three-level CRTs designs. © The Author(s) 2016.

  20. Intra-rater reliability of cervical sensory motor function and cervical reconstruction test in healthy subjects

    Directory of Open Access Journals (Sweden)

    Hatamvand S

    2016-07-01

    Full Text Available Impairment of cervicocephalic and head joint position sense has an important role in the recurrent and chronic of cervicocephalic pain. The various tools are suggested for evaluating the cervicocephalic joint position sense. Although reconstruction of cervical angle is a clinical criterion for measuring the cervicocephalic proprioception, the reliability of this method has not been completely accepted. The purpose of this study was to evaluate intra-rater reliability of cervical sensory motor function and cervical reconstruction test in healthy subjects. twenty four healthy subjects (25.70±6.08 y through simple non-probability sampling participated in this single-group repeatedmeasures reliability study. Participants were asked to relocate the neck, as accurately as possible, after full active cervical flexion, extension and rotation to the left and right sides. Five trials were performed for each movement. Laser pointer was used in head of patient. The distance between zero spot and joint position which patient had been reconstructed, was measured by centimeter. Intra-class correlation Coefficient (ICCs and Pearson's correlation coefficient test was used to determine intra-rater reliability of variables. The results showed that intra-class correlation Coefficient (ICCs values with 95% confidence interval (CI and the standard error of the measurement (SEM were good to excellent agreement for a single investigator between measurement occasions. Intra-class correlation Coefficient (ICCs values were obtained for flexion movement (ICCs:0.75, good, extension movement (ICCs:0.81, very good, right rotation (ICCs:0.64, good and left rotation (ICCs:0.64, good. The cervicocephalic relocation test to neutral head position by laser pointer is a reliable method to measure cervical sensory motor function. Therefore, it can be used for evaluating cervicocephalic proprioception of patient with cervicocephalic pain.

  1. Validity and reliability of the single-trial line drill test of anaerobic power in basketball players.

    Science.gov (United States)

    Fatouros, I G; Laparidis, K; Kambas, A; Chatzinikolaou, A; Techlikidou, E; Katrabasas, I; Douroudos, I; Leontsini, D; Berberidou, F; Draganidis, D; Christoforidis, C; Tsoukas, D; Kelis, S; Taxildaris, K

    2011-03-01

    This study evaluated the validity, reliability, and sensitivity of the single-trial line drill test (SLDT) for anaerobic power assessment. Twenty-four volunteers were assigned to either a control (C, N.=12) or an experimental (BP, N.=12 basketball players) group. SLDT's (time-to-complete) concurrent validity was evaluated against the Wingate testing (WAnT: mean [MP] and peak power [PP]) and a 30-sec vertical jump testing test (VJT: mean height and MP). Blood lactate concentration was measured at rest and immediately post-test. SLDT's reliability [test-retest intraclass correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots] and sensitivity were determined (one-way ANOVA). Kendall's tau correlation analysis revealed correlations (Pbasketball players.

  2. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review.

    Science.gov (United States)

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-09-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.

  3. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    Science.gov (United States)

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. The test-retest reliability and criterion validity of a high-intensity, netball-specific circuit test: The Net-Test.

    Science.gov (United States)

    Mungovan, Sean F; Peralta, Paula J; Gass, Gregory C; Scanlan, Aaron T

    2018-04-12

    To examine the test-retest reliability and criterion validity of a high-intensity, netball-specific fitness test. Repeated measures, within-subject design. Eighteen female netball players competing in an international competition completed a trial of the Net-Test, which consists of 14 timed netball-specific movements. Players also completed a series of netball-relevant criterion fitness tests. Ten players completed an additional Net-Test trial one week later to assess test-retest reliability using intraclass correlation coefficient (ICC), typical error of measurement (TEM), and coefficient of variation (CV). The typical error of estimate expressed as CV and Pearson correlations were calculated between each criterion test and Net-Test performance to assess criterion validity. Five movements during the Net-Test displayed moderate ICC (0.84-0.90) and two movements displayed high ICC (0.91-0.93). Seven movements and heart rate taken during the Net-Test held low CV (Test possessed low CV and significant (pTest possesses acceptable reliability for the assessment of netball fitness. Further, the high criterion validity for the Net-Test suggests a range of important netball-specific fitness elements are assessed in combination. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  6. Hypothesis testing for differentially correlated features.

    Science.gov (United States)

    Sheng, Elisa; Witten, Daniela; Zhou, Xiao-Hua

    2016-10-01

    In a multivariate setting, we consider the task of identifying features whose correlations with the other features differ across conditions. Such correlation shifts may occur independently of mean shifts, or differences in the means of the individual features across conditions. Previous approaches for detecting correlation shifts consider features simultaneously, by computing a correlation-based test statistic for each feature. However, since correlations involve two features, such approaches do not lend themselves to identifying which feature is the culprit. In this article, we instead consider a serial testing approach, by comparing columns of the sample correlation matrix across two conditions, and removing one feature at a time. Our method provides a novel perspective and favorable empirical results compared with competing approaches. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Reliability, sensitivity and validity of the assistant referee intermittent endurance test (ARIET) - a modified Yo-Yo IE2 test for elite soccer assistant referees

    DEFF Research Database (Denmark)

    Castagna, Carlo; Bendiksen, Mads; Impellizzeri, Franco M

    2012-01-01

    We examined the reliability and validity of the assistant referee intermittent endurance test (ARIET), a modified Yo-Yo IE2 test including shuttles of sideways running. The ARIET was carried out on 198 Italian (Serie A-B, Lega-Pro and National Level) and 47 Danish elite soccer assistant referees....... Reproducibility was tested for 41 assistant referees on four occasions each separated by one week. The ARIET intraclass correlation coefficients and typical error of measurement ranged from 0.96 to 0.99 and 3.1 to 5.7%, respectively. ARIET performance for Serie A and B was 23 and 25% greater than in Lega-Pro (P...... ARIET performance was significantly correlated with VO(2max) (r = 0.78, P ARIET (r = - 0.81, P

  8. Estimation of macular pigment optical density in the elderly: test-retest variability and effect of optical blur in pseudophakic subjects

    NARCIS (Netherlands)

    Gallaher, Kevin T.; Mura, Marco; Todd, Wm Andrew; Harris, Tarsha L.; Kenyon, Emily; Harris, Tamara; Johnson, Karen C.; Satterfield, Suzanne; Kritchevsky, Stephen B.; Iannaccone, Alessandro

    2007-01-01

    The reproducibility of macular pigment optical density (MPOD) estimates in the elderly was assessed in 40 subjects (age: 79.1+/-3.5). Test-retest variability was good (Pearson's r coefficient: 0.734), with an average coefficient of variation (CV) of 18.4% and an intraclass correlation coefficient

  9. Arm cranking versus wheelchair propulsion for testing aerobic fitness in children with spina bifida who are wheelchair dependent.

    Science.gov (United States)

    Bloemen, Manon A T; de Groot, Janke F; Backx, Frank J G; Westerveld, Rosalyne A; Takken, Tim

    2015-05-01

    To determine the best test performance and feasibility using a Graded Arm Cranking Test vs a Graded Wheelchair Propulsion Test in young people with spina bifida who use a wheelchair, and to determine the reliability of the best test. Validity and reliability study. Young people with spina bifida who use a wheelchair. Physiological responses were measured during a Graded Arm Cranking Test and a Graded Wheelchair Propulsion Test using a heart rate monitor and calibrated mobile gas analysis system (Cortex Metamax). For validity, peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) were compared using paired t-tests. For reliability, the intra-class correlation coefficients, standard error of measurement, and standard detectable change were calculated. VO2peak and HRpeak were higher during wheelchair propulsion compared with arm cranking (23.1 vs 19.5 ml/kg/min, p = 0.11; 165 vs 150 beats/min, p propulsion showed high intra-class correlation coefficients (ICCs) for both VO2peak (ICC = 0.93) and HRpeak (ICC = 0.90). This pilot study shows higher HRpeak and a tendency to higher VO2peak in young people with spina bifida who are using a wheelchair when tested during wheelchair propulsion compared with arm cranking. Wheelchair propulsion showed good reliability. We recommend performing a wheelchair propulsion test for aerobic fitness testing in this population.

  10. Content validity and reliability of test of gross motor development in Chilean children

    Directory of Open Access Journals (Sweden)

    Marcelo Cano-Cappellacci

    2015-01-01

    Full Text Available ABSTRACT OBJECTIVE To validate a Spanish version of the Test of Gross Motor Development (TGMD-2 for the Chilean population. METHODS Descriptive, transversal, non-experimental validity and reliability study. Four translators, three experts and 92 Chilean children, from five to 10 years, students from a primary school in Santiago, Chile, have participated. The Committee of Experts has carried out translation, back-translation and revision processes to determine the translinguistic equivalence and content validity of the test, using the content validity index in 2013. In addition, a pilot implementation was achieved to determine test reliability in Spanish, by using the intraclass correlation coefficient and Bland-Altman method. We evaluated whether the results presented significant differences by replacing the bat with a racket, using T-test. RESULTS We obtained a content validity index higher than 0.80 for language clarity and relevance of the TGMD-2 for children. There were significant differences in the object control subtest when comparing the results with bat and racket. The intraclass correlation coefficient for reliability inter-rater, intra-rater and test-retest reliability was greater than 0.80 in all cases. CONCLUSIONS The TGMD-2 has appropriate content validity to be applied in the Chilean population. The reliability of this test is within the appropriate parameters and its use could be recommended in this population after the establishment of normative data, setting a further precedent for the validation in other Latin American countries.

  11. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  12. Reliability and Concurrent Validity of the Narrow Path Walking Test in Persons With Multiple Sclerosis.

    Science.gov (United States)

    Rosenblum, Uri; Melzer, Itshak

    2017-01-01

    About 90% of people with multiple sclerosis (PwMS) have gait instability and 50% fall. Reliable and clinically feasible methods of gait instability assessment are needed. The study investigated the reliability and validity of the Narrow Path Walking Test (NPWT) under single-task (ST) and dual-task (DT) conditions for PwMS. Thirty PwMS performed the NPWT on 2 different occasions, a week apart. Number of Steps, Trial Time, Trial Velocity, Step Length, Number of Step Errors, Number of Cognitive Task Errors, and Number of Balance Losses were measured. Intraclass correlation coefficients (ICC2,1) were calculated from the average values of NPWT parameters. Absolute reliability was quantified from standard error of measurement (SEM) and smallest real difference (SRD). Concurrent validity of NPWT with Functional Reach Test, Four Square Step Test (FSST), 12-item Multiple Sclerosis Walking Scale (MSWS-12), and 2 Minute Walking Test (2MWT) was determined using partial correlations. Intraclass correlation coefficients (ICCs) for most NPWT parameters during ST and DT ranged from 0.46-0.94 and 0.55-0.95, respectively. The highest relative reliability was found for Number of Step Errors (ICC = 0.94 and 0.93, for ST and DT, respectively) and Trial Velocity (ICC = 0.83 and 0.86, for ST and DT, respectively). Absolute reliability was high for Number of Step Errors in ST (SEM % = 19.53%) and DT (SEM % = 18.14%) and low for Trial Velocity in ST (SEM % = 6.88%) and DT (SEM % = 7.29%). Significant correlations for Number of Step Errors and Trial Velocity were found with FSST, MSWS-12, and 2MWT. In persons with PwMS performing the NPWT, Number of Step Errors and Trial Velocity were highly reliable parameters. Based on correlations with other measures of gait instability, Number of Step Errors was the most valid parameter of dynamic balance under the conditions of our test.Video Abstract available for more insights from the authors (see Supplemental Digital Content 1, available at: http

  13. Improved estimation of subject-level functional connectivity using full and partial correlation with empirical Bayes shrinkage.

    Science.gov (United States)

    Mejia, Amanda F; Nebel, Mary Beth; Barber, Anita D; Choe, Ann S; Pekar, James J; Caffo, Brian S; Lindquist, Martin A

    2018-05-15

    Reliability of subject-level resting-state functional connectivity (FC) is determined in part by the statistical techniques employed in its estimation. Methods that pool information across subjects to inform estimation of subject-level effects (e.g., Bayesian approaches) have been shown to enhance reliability of subject-level FC. However, fully Bayesian approaches are computationally demanding, while empirical Bayesian approaches typically rely on using repeated measures to estimate the variance components in the model. Here, we avoid the need for repeated measures by proposing a novel measurement error model for FC describing the different sources of variance and error, which we use to perform empirical Bayes shrinkage of subject-level FC towards the group average. In addition, since the traditional intra-class correlation coefficient (ICC) is inappropriate for biased estimates, we propose a new reliability measure denoted the mean squared error intra-class correlation coefficient (ICC MSE ) to properly assess the reliability of the resulting (biased) estimates. We apply the proposed techniques to test-retest resting-state fMRI data on 461 subjects from the Human Connectome Project to estimate connectivity between 100 regions identified through independent components analysis (ICA). We consider both correlation and partial correlation as the measure of FC and assess the benefit of shrinkage for each measure, as well as the effects of scan duration. We find that shrinkage estimates of subject-level FC exhibit substantially greater reliability than traditional estimates across various scan durations, even for the most reliable connections and regardless of connectivity measure. Additionally, we find partial correlation reliability to be highly sensitive to the choice of penalty term, and to be generally worse than that of full correlations except for certain connections and a narrow range of penalty values. This suggests that the penalty needs to be chosen carefully

  14. The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.

    Science.gov (United States)

    Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro

    2016-01-01

    Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.

  15. The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.

    Directory of Open Access Journals (Sweden)

    Yasuyuki Mamiya

    Full Text Available Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB, and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test.The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD and 20 healthy controls (HCs. We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC and the concurrent validity using the Neuropsychiatric Inventory (NPI hallucinations score as a reference. A receiver operating characteristic (ROC analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs.The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82, and moderately correlated with the NPI hallucinations score (rs = 0.42. Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%.Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.

  16. Sequential accelerated tests: Improving the correlation of accelerated tests to module performance in the field

    Science.gov (United States)

    Felder, Thomas; Gambogi, William; Stika, Katherine; Yu, Bao-Ling; Bradley, Alex; Hu, Hongjie; Garreau-Iles, Lucie; Trout, T. John

    2016-09-01

    DuPont has been working steadily to develop accelerated backsheet tests that correlate with solar panels observations in the field. This report updates efforts in sequential testing. Single exposure tests are more commonly used and can be completed more quickly, and certain tests provide helpful predictions of certain backsheet failure modes. DuPont recommendations for single exposure tests are based on 25-year exposure levels for UV and humidity/temperature, and form a good basis for sequential test development. We recommend a sequential exposure of damp heat followed by UV then repetitions of thermal cycling and UVA. This sequence preserves 25-year exposure levels for humidity/temperature and UV, and correlates well with a large body of field observations. Measurements can be taken at intervals in the test, although the full test runs 10 months. A second, shorter sequential test based on damp heat and thermal cycling tests mechanical durability and correlates with loss of mechanical properties seen in the field. Ongoing work is directed toward shorter sequential tests that preserve good correlation to field data.

  17. [Lack of correlation between performances in a simulator and in reality].

    Science.gov (United States)

    Konge, Lars; Bitsch, Mikael

    2010-12-13

    Simulation-based training provides obvious benefits for patients and doctors in education. Frequently, virtual reality simulators are expensive and evidence for their efficacy is poor, particularly as a result of studies with poor methodology and few test participants. In medical simulated training- and evaluation programmes it is always a question of transfer to the real clinical world. To illustrate this problem a study comparing the test performance of persons on a bowling simulator with their performance in a real bowling alley was conducted. Twenty-five test subjects played two rounds of bowling on a Nintendo Wii and 25 days later on a real bowling alley. Correlations of the scores in the first and second round (test-retest-reliability) and of the scores on the simulator and in reality (criterion validation) were studied and there was tested for any difference between female and male performance. The intraclass correlation coefficient equalled 0.76, i.e. the simulator fairly accurately measured participant performance. In contrast to this there was absolutely no correlation between participants' real bowling abilities and their scores on the simulator (Pearson's r = 0.06). There was no significant difference between female and male abilities. Simulation-based testing and training must be based on evidence. More studies are needed to include an adequate number of subjects. Bowling competence should not be based on Nintendo Wii measurements. Simulated training- and evaluation programmes should be validated before introduction, to ensure consistency with the real world.

  18. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    Science.gov (United States)

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  19. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Stair negotiation in women with fibromyalgia: A descriptive correlational study.

    Science.gov (United States)

    Collado-Mateo, Daniel; Domínguez-Muñoz, Francisco J; Olivares, Pedro R; Adsuar, José C; Gusi, Narcis

    2017-10-01

    Walking up and down stairs is a common and important activity of daily living. Women with fibromyalgia often show a reduced ability to perform this task.The objective of this study was to evaluate the test-retest reliability of stair negotiation tasks and to assess the impact of fibromyalgia symptoms on the ability to negotiate stairs.Forty-two women with fibromyalgia participated in this descriptive correlational study. The relevance of the stair negotiation (both walking up and down) was evaluated by assessing its association with the revised version of the fibromyalgia impact questionnaire (FIQ-R) and other health-related variables. Test-retest reliability was also analyzed. The main outcome measures were time spent walking up and down stairs and impact of fibromyalgia, quality of life, number of falls, weight, and lower limb strength and endurance.The intraclass correlation coefficient (ICC) for stair descent was 0.929 whereas that for ascent was 0.972. The score in these tests correlated significantly with the total score for the FIQ-R and the score for many of dimensions and symptoms: that is, physical function, overall impact of fibromyalgia, pain, energy, stiffness, restorative sleep, tenderness, self-perceived balance problems, and sensitivity.Given the importance of the stair negotiation as activity of daily living and the high reliability, both stair ascent and descent tasks may be useful as outcome measures in studies on patients with fibromyalgia.

  1. Assessing the test-retest repeatability of the Vietnamese version of the National Eye Institute 25-item Visual Function Questionnaire among bilateral cataract patients for a Vietnamese population.

    Science.gov (United States)

    To, Kien Gia; Meuleners, Lynn; Chen, Huei-Yang; Lee, Andy; Do, Dung Van; Duong, Dat Van; Phi, Tien Duy; Tran, Hoang Huy; Nguyen, Nguyen Do

    2014-06-01

    To determine the test-retest repeatability of the National Eye Institute 25-item Visual Function Questionnaire (NEI VFQ-25) for use with older Vietnamese adults with bilateral cataract. The questionnaire was translated into Vietnamese and back-translated into English by two independent translators. Patients with bilateral cataract aged 50 and older completed the questionnaire on two separate occasions, one to two weeks after first administration of the questionnaire. Test-retest repeatability was assessed using the Cronbach's α and intraclass correlation coefficients. The average age of participants was 67 ± 8 years and most participants were female (73%). Internal consistency was acceptable with the α coefficient above 0.7 for all subscales and intraclass correlation coefficients were 0.6 or greater in all subscales. The Vietnamese NEI VFQ-25 is reliable for use in studies assessing vision-related quality of life in older adults with bilateral cataract in Vietnam. We propose some modifications to the NEI-VFQ questions to reflect activities of older people in Vietnam. © 2013 ACOTA.

  2. Validity of a cross-specialty test in basic laparoscopic techniques (TABLT)

    DEFF Research Database (Denmark)

    Thinggaard, Ebbe; Bjerrum, Flemming; Strandbygaard, Jeanett

    2015-01-01

    . The aim of this study was to establish validity evidence for the Training and Assessment of Basic Laparoscopic Techniques (TABLT) test, a tablet-based training system. METHODS: Laparoscopic surgeons and trainees were recruited from departments of general surgery, gynaecology and urology. Participants...... included novice, intermediate and experienced surgeons. All participants performed the TABLT test. Performance scores were calculated based on time taken and errors made. Evidence of validity was explored using a contemporary framework of validity. RESULTS: Some 60 individuals participated. The TABLT...... was shown to be reliable, with an intraclass correlation coefficient of 0·99 (P value of 0·73 (P 

  3. Kolmogorov-Smirnov test for spatially correlated data

    Science.gov (United States)

    Olea, R.A.; Pawlowsky-Glahn, V.

    2009-01-01

    The Kolmogorov-Smirnov test is a convenient method for investigating whether two underlying univariate probability distributions can be regarded as undistinguishable from each other or whether an underlying probability distribution differs from a hypothesized distribution. Application of the test requires that the sample be unbiased and the outcomes be independent and identically distributed, conditions that are violated in several degrees by spatially continuous attributes, such as topographical elevation. A generalized form of the bootstrap method is used here for the purpose of modeling the distribution of the statistic D of the Kolmogorov-Smirnov test. The innovation is in the resampling, which in the traditional formulation of bootstrap is done by drawing from the empirical sample with replacement presuming independence. The generalization consists of preparing resamplings with the same spatial correlation as the empirical sample. This is accomplished by reading the value of unconditional stochastic realizations at the sampling locations, realizations that are generated by simulated annealing. The new approach was tested by two empirical samples taken from an exhaustive sample closely following a lognormal distribution. One sample was a regular, unbiased sample while the other one was a clustered, preferential sample that had to be preprocessed. Our results show that the p-value for the spatially correlated case is always larger that the p-value of the statistic in the absence of spatial correlation, which is in agreement with the fact that the information content of an uncorrelated sample is larger than the one for a spatially correlated sample of the same size. ?? Springer-Verlag 2008.

  4. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). RESULTS: ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0...

  5. Intra-unit correlations in seroconversion to Actinobacillus pleuropneumoniae and Mycoplasma hyopneumoniae at different levels in Danish multi-site pig production facilities

    DEFF Research Database (Denmark)

    Vigre, Håkan; Dohoo, I.R.; Stryhn, H.

    2004-01-01

    2) and Mycoplasma hyopneumoniae (Mh). Based on the estimated variances, three newly described computational methods (model linearisation, simulation and linear modelling) and the standard method (latent-variable approach) were used to estimate the correlations (intra-class correlation components...

  6. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    Directory of Open Access Journals (Sweden)

    Jason G. Langley, Robert D. Chetlin

    2017-03-01

    Full Text Available Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT, and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test, three to the left (3CTL, and two modified trials (3CTAR and 3CTAL, which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI, 3CTL 0.73 (0.55-0.85, 3CTAR 0.85(0.74-0.92, and 3CTAL 0.79 (0.64-0.88. Small standard error of the measurement (SEM was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92 on day one as well as day two (0.72-0.85. These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions.

  7. Assessing self-reported disability in a low-literate population with chronic low back pain: cross-cultural adaptation and psychometric testing of Igbo Roland Morris disability questionnaire.

    Science.gov (United States)

    Igwesi-Chidobe, Chinonso N; Obiekwe, Chinwe; Sorinola, Isaac O; Godfrey, Emma L

    2017-12-14

    Cross-culturally adapt and validate the Igbo Roland Morris Disability Questionnaire. Cross-cultural adaptation, test-retest, and cross-sectional psychometric testing. Roland Morris Disability Questionnaire was forward and back translated by clinical/non-clinical translators. An expert committee appraised the translations. Twelve participants with chronic low back pain pre-tested the measure in a rural Nigerian community. Internal consistency using Cronbach's alpha; test-retest reliability using intra-class correlation coefficient and Bland-Altman plot; and minimal detectable change were investigated in a convenient sample of 50 people with chronic low back pain in rural and urban Nigeria. Pearson's correlation analyses using the eleven-point box scale and back performance scale, and exploratory factor analysis were used to examine construct validity in a random sample of 200 adults with chronic low back pain in rural Nigeria. Ceiling and floor effects were investigated in the two samples. Modifications gave the option of interviewer-administration and reflected Nigerian social context. The measure had excellent internal consistency (α = 0.91) and intraclass correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity, and a predominant uni-dimensional structure, with no ceiling or floor effects. Igbo Roland Morris Disability Questionnaire is a valid and reliable measure of pain-related disability. Implications for rehabilitation Low back pain is the leading cause of years lived with disability worldwide, and is particularly prevalent in rural Nigeria, but there are no self-report measures to assess its impact due to low literacy rates. This study describes the cross-cultural adaptation and validation of a core self-report back pain specific disability measure in a low-literate Nigerian population. The Igbo Roland Morris Disability Questionnaire is a reliable and valid measure of self

  8. Reliability and validity of two isometric squat tests.

    Science.gov (United States)

    Blazevich, Anthony J; Gill, Nicholas; Newton, Robert U

    2002-05-01

    The purpose of the present study was first to examine the reliability of isometric squat (IS) and isometric forward hack squat (IFHS) tests to determine if repeated measures on the same subjects yielded reliable results. The second purpose was to examine the relation between isometric and dynamic measures of strength to assess validity. Fourteen male subjects performed maximal IS and IFHS tests on 2 occasions and 1 repetition maximum (1-RM) free-weight squat and forward hack squat (FHS) tests on 1 occasion. The 2 tests were found to be highly reliable (intraclass correlation coefficient [ICC](IS) = 0.97 and ICC(IFHS) = 1.00). There was a strong relation between average IS and 1-RM squat performance, and between IFHS and 1-RM FHS performance (r(squat) = 0.77, r(FHS) = 0.76; p squat and FHS test performances (r squat and FHS test performance can be attributed to differences in the movement patterns of the tests

  9. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  10. Correlation analysis for forced vibration test of the Hualien large scale seismic test (LSST) program

    International Nuclear Information System (INIS)

    Sugawara, Y.; Sugiyama, T.; Kobayashi, T.; Yamaya, H.; Kitamura, E.

    1995-01-01

    The correlation analysis for a forced vibration test of a 1/4-scale containment SSI test model constructed in Hualien, Taiwan was carried out for the case of after backfilling. Prior to this correlation analysis, the structural properties were revised to adjust the calculated fundamental frequency in the fixed base condition to that derived from the test results. A correlation analysis was carried out using the Lattice Model which was able to estimate the soil-structure effects with embedment. The analysis results coincide well with test results and it is concluded that the mathematical soil-structure interaction model established by the correlation analysis is efficient in estimating the dynamic soil-structure interaction effect with embedment. This mathematical model will be applied as a basic model for simulation analysis of earthquake observation records. (author). 3 refs., 12 figs., 2 tabs

  11. How accurate are national stereotypes? A test of different methodological approaches

    Czech Academy of Sciences Publication Activity Database

    Hřebíčková, Martina; Mõttus, R.; Graf, Sylvie; Jelínek, Martin; Realo, A.

    2018-01-01

    Roč. 32, duben (2018), s. 87-99 ISSN 0890-2070 R&D Projects: GA ČR(CZ) GA17-14387S Institutional support: RVO:68081740 Keywords : national stereotypes * stereotype accuracy * intraclass correlations * rank-order correlations Subject RIV: AN - Psychology OBOR OECD: Psychology (including human - machine relations) Impact factor: 3.707, year: 2016

  12. Northern Chinese dental ages estimated from southern Chinese reference datasets closely correlate with chronological age

    Directory of Open Access Journals (Sweden)

    Hai Ming Wong

    2016-12-01

    Full Text Available While northern and southern Chinese are genetically correlated, there exists notable environmental differences in their living conditions. This study aimed to evaluate validity of the southern Chinese reference dataset for dental age estimation applied to northern Chinese. Dental panoramic tomographs of 437 northern Chinese aged 3 to 21 years were analysed. All the left maxillary and mandibular permanent teeth plus the 2 third molars on the right side were scored based on Demirjian’s classification of tooth development stages. Mean and standard error of dental age were obtained for each tooth development stage, followed by random effect meta-analysis for mean dental age estimation. Validity of the method was examined through measures of agreement (95% limits of agreement, standard error of measurement, and Lin’s concordance correlation coefficient and measure of reliability (Intraclass correlation coefficient. On average, the estimated dental age overestimated chronological age by only around 1 month in both females and males. The Intraclass correlation coefficient values were 0.99 for both sexes, suggesting excellent reliability of the method. Reference dataset for dental age estimation developed on the basis of southern Chinese was applicable for use among the northern Chinese.

  13. A Systematic Review of Statistical Methods Used to Test for Reliability of Medical Instruments Measuring Continuous Variables

    Directory of Open Access Journals (Sweden)

    Rafdzah Zaki

    2013-06-01

    Full Text Available   Objective(s: Reliability measures precision or the extent to which test results can be replicated. This is the first ever systematic review to identify statistical methods used to measure reliability of equipment measuring continuous variables. This studyalso aims to highlight the inappropriate statistical method used in the reliability analysis and its implication in the medical practice.   Materials and Methods: In 2010, five electronic databases were searched between 2007 and 2009 to look for reliability studies. A total of 5,795 titles were initially identified. Only 282 titles were potentially related, and finally 42 fitted the inclusion criteria. Results: The Intra-class Correlation Coefficient (ICC is the most popular method with 25 (60% studies having used this method followed by the comparing means (8 or 19%. Out of 25 studies using the ICC, only 7 (28% reported the confidence intervals and types of ICC used. Most studies (71% also tested the agreement of instruments. Conclusion: This study finds that the Intra-class Correlation Coefficient is the most popular method used to assess the reliability of medical instruments measuring continuous outcomes. There are also inappropriate applications and interpretations of statistical methods in some studies. It is important for medical researchers to be aware of this issue, and be able to correctly perform analysis in reliability studies.

  14. The 1-min sit-to-stand test--A simple functional capacity test in cystic fibrosis?

    Science.gov (United States)

    Radtke, Thomas; Puhan, Milo A; Hebestreit, Helge; Kriemler, Susi

    2016-03-01

    We aimed to assess the measurement properties and the minimal important difference (MID) of the 1-min sit-to-stand (STS) test in cystic fibrosis (CF). Patients with CF were tested during a pulmonary rehabilitation program. Five STS tests were performed during the program; two tests at the beginning (STS0 and STS1) and three tests at the end (STS2a-2c). Exercise capacity, pulmonary function, and health-related quality of life (HRQoL) and patient-reported health status were measured at the beginning and end of the program. We calculated overall mean, standard deviation, coefficient of variation (CV), and intraclass correlation coefficient (ICC) of the STS test. The MID was calculated using anchor-based and distributional methods. Fourteen participants (8 female, mean age 30.4±6.1years) were included. STS test performance increased significantly from STS0 to STS1 indicative of a learning effect. Test-retest reliability for the subsequent STS2a-2c tests was excellent (ICC 0.98, 95% CI 0.96-0.99). The estimated MID for the STS test was 5 repetitions. STS test performance was responsive to change (effect size of 0.97) and correlated with exercise capacity (r=0.63-0.73) and with the physical functioning HRQoL scale (r=0.72). The 1-min STS test appears to be a reliable, valid, and feasible test to measure functional capacity in patients with CF. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  15. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing

    Science.gov (United States)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerone C.; Kolody, Mark R.

    2011-01-01

    Evaluation of metal-based structures has long relied on atmospheric exposure test sites to determine corrosion resistance in marine environments. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions of the corrosive environment. Their success for correlation to atmospheric exposure is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated laboratory testing, which often focuses on the electrochemical reactions that occur during corrosion conditions, has yet to be universally accepted as a useful tool in predicting the long term service life of a metal despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard and their use is imperative, a method that correlates timescales from atmospheric exposure to accelerated testing would be very valuable. This work uses surface chemistry to interpret the chemical changes occurring on low carbon steel during atmospheric and accelerated corrosion conditions with the objective of finding a correlation between its accelerated and long-term corrosion performance. The current results of correlating data from marine atmospheric exposure conditions at the Kennedy Space Center beachside corrosion test site, alternating seawater spray, and immersion in typical electrochemical laboratory conditions, will be presented. Key words: atmospheric exposure, accelerated corrosion testing, alternating seawater spray, marine, correlation, seawater, carbon steel, long-term corrosion performance prediction, X-ray photoelectron spectroscopy.

  16. Correlation between HRCT and pulmonary functional tests in cystic fibrosis

    International Nuclear Information System (INIS)

    Mastellari, Paola; Biggi, Simona; Lombardi, Alfonsa; Zompatori, Maurizio; Grzincich, Gianluigi; Pisi, Giovanna; Spaggiari, Cinzia

    2005-01-01

    Purpose. To compare the HRCT score by Oikonottlou and air trapping in expiratory scans with pulmonary functional tests and evaluate which radiological criteria are more useful to predict clinical impairment. Materials and methods. From January to September 2003, pulmonary HRCT study was performed in 37 patients (23 males), aged between 7 and 41 years, with cystic fibrosis. In the same day of CT examination they also received a complete functional evaluation. HRCT studies were evaluated by three radiologists blinded to the clinical data and were correlated with the lung function tests. Results. We obtained a high correlation (p=0.01) for two of the HRCT signs: extent of mucus plugging and mosaic perfusion pattern and all function tests. Discussion. Previous studies have demonstrated good correlation between lung function tests, in particular with FEV1 and HRCT signs. Our study differed from previous ones in that we analysed the correlation between lung function tests and with both single and combined CT criteria. Conclusion. Our results suggest that a simplified HRCT store could be useful to evaluate patients with cystic fibrosis [it

  17. Development of Test-Analysis Models (TAM) for correlation of dynamic test and analysis results

    Science.gov (United States)

    Angelucci, Filippo; Javeed, Mehzad; Mcgowan, Paul

    1992-01-01

    The primary objective of structural analysis of aerospace applications is to obtain a verified finite element model (FEM). The verified FEM can be used for loads analysis, evaluate structural modifications, or design control systems. Verification of the FEM is generally obtained as the result of correlating test and FEM models. A test analysis model (TAM) is very useful in the correlation process. A TAM is essentially a FEM reduced to the size of the test model, which attempts to preserve the dynamic characteristics of the original FEM in the analysis range of interest. Numerous methods for generating TAMs have been developed in the literature. The major emphasis of this paper is a description of the procedures necessary for creation of the TAM and the correlation of the reduced models with the FEM or the test results. Herein, three methods are discussed, namely Guyan, Improved Reduced System (IRS), and Hybrid. Also included are the procedures for performing these analyses using MSC/NASTRAN. Finally, application of the TAM process is demonstrated with an experimental test configuration of a ten bay cantilevered truss structure.

  18. Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.

    Science.gov (United States)

    Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio

    2014-01-01

    The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQIntelligence Scale IQ (BIQ) was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96). In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9), and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4). Thus, intellectual disability could be ruled out or determined. The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.

  19. Testing the Difference of Correlated Agreement Coefficients for Statistical Significance

    Science.gov (United States)

    Gwet, Kilem L.

    2016-01-01

    This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…

  20. Practice effects and test-re-test reliability of the Five Digit Test in patients with stroke over four serial assessments.

    Science.gov (United States)

    Chiu, En-Chi; Koh, Chia-Lin; Tsai, Chia-Yin; Lu, Wen-Shian; Sheu, Ching-Fan; Hsueh, I-Ping; Hsieh, Ching-Lin

    2014-01-01

    To investigate practice effect and test-re-test reliability of the Five Digit Test (FDT) over four serial assessments in patients with stroke. Single-group repeated measures design. Twenty-five patients with stroke were administered the FDT in four consecutive assessments every 2 weeks. The FDT contains four parts with five indices: 'basic measures of attention and processing speed', 'selective attention', 'alternating attention', 'ability of inhibition' and 'ability of switching'. The five indices of the FDT showed trivial-to-small practice effects (Cohen's d = 0.03-0.47) and moderate-to-excellent test-re-test reliability (intra-class correlation coefficient = 0.59-0.97). Practice effects of the five indices all appeared cumulative, but one index, 'basic measures of attention and processing speed', reached a plateau after the second assessment. The minimum and maximum values of the 90% confidence interval (CI) of reliable change index modified for practice (RCIp) for this index were [-17.6, 11.2]. One of five indices of the FDT reached a plateau, whose minimum and maximum values of the 90% CI RCIp are useful to determine whether the change in an individual's score is real. However, clinicians and researchers should be cautious when interpreting the test results of these four indices over repeated assessments.

  1. Intraclass reliability for assessing how well Taiwan constrained hospital-provided medical services using statistical process control chart techniques.

    Science.gov (United States)

    Chien, Tsair-Wei; Chou, Ming-Ting; Wang, Wen-Chung; Tsai, Li-Shu; Lin, Weir-Sen

    2012-05-15

    Few studies discuss the indicators used to assess the effect on cost containment in healthcare across hospitals in a single-payer national healthcare system with constrained medical resources. We present the intraclass correlation coefficient (ICC) to assess how well Taiwan constrained hospital-provided medical services in such a system. A custom Excel-VBA routine to record the distances of standard deviations (SDs) from the central line (the mean over the previous 12 months) of a control chart was used to construct and scale annual medical expenditures sequentially from 2000 to 2009 for 421 hospitals in Taiwan to generate the ICC. The ICC was then used to evaluate Taiwan's year-based convergent power to remain unchanged in hospital-provided constrained medical services. A bubble chart of SDs for a specific month was generated to present the effects of using control charts in a national healthcare system. ICCs were generated for Taiwan's year-based convergent power to constrain its medical services from 2000 to 2009. All hospital groups showed a gradually well-controlled supply of services that decreased from 0.772 to 0.415. The bubble chart identified outlier hospitals that required investigation of possible excessive reimbursements in a specific time period. We recommend using the ICC to annually assess a nation's year-based convergent power to constrain medical services across hospitals. Using sequential control charts to regularly monitor hospital reimbursements is required to achieve financial control in a single-payer nationwide healthcare system.

  2. RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Serna, Jorge; Rhea, Matthew R; Marín, Pedro J

    2015-10-01

    Sprinting and jumping are two common and important components of high-level sport performance. The weight-bearing dorsiflexion test (WB-DF) and Star Excursion Balance Test (SEBT) are tools developed to identify athletes at risk for lower extremity injury and may be related to running and jumping performance among athletes. The purposes of the present study were: 1) to identify any relationships between functional movement tests (WB-DF and SEBT) and performance tests (jumping, sprinting and changing direction); 2) to examine any relationships between asymmetries in functional movements and performance tests. Descriptive cohort study. Fifteen elite male basketball players (age: 15.4 ± 0.9 years) were assessed during a three-week period to determine the reliability of functional screening tools and performance tests and to examine the relationships between these tests. Relative (intraclass correlation coefficient) and absolute (coefficient of variation) reliability were used to assess the reproducibility of the tests. Significant correlations were detected between certain functional movement tests and performance tests. Both left and right excursion composite scores related to slower performance times in sprint testing, demonstrating that greater dynamic reach relates to decreased quickness and acceleration among these elite basketball athletes. The various relationships between dynamic functional movement testing, speed, and jump performance provide guidance for the strength and conditioning professional when conducting and evaluating data in an effort to improve performance and reduce risk of injury. The results of the present study suggest that these functional and performance tests do not measure the same components of human movement, and could be paired as outcome measures for the clinical and sport assessment of lower extremity function. 2b.

  3. Significance levels for studies with correlated test statistics.

    Science.gov (United States)

    Shi, Jianxin; Levinson, Douglas F; Whittemore, Alice S

    2008-07-01

    When testing large numbers of null hypotheses, one needs to assess the evidence against the global null hypothesis that none of the hypotheses is false. Such evidence typically is based on the test statistic of the largest magnitude, whose statistical significance is evaluated by permuting the sample units to simulate its null distribution. Efron (2007) has noted that correlation among the test statistics can induce substantial interstudy variation in the shapes of their histograms, which may cause misleading tail counts. Here, we show that permutation-based estimates of the overall significance level also can be misleading when the test statistics are correlated. We propose that such estimates be conditioned on a simple measure of the spread of the observed histogram, and we provide a method for obtaining conditional significance levels. We justify this conditioning using the conditionality principle described by Cox and Hinkley (1974). Application of the method to gene expression data illustrates the circumstances when conditional significance levels are needed.

  4. Cross-cultural validation and psychometric testing of the Norwegian version of the TeamSTEPPS® teamwork perceptions questionnaire.

    Science.gov (United States)

    Ballangrud, Randi; Husebø, Sissel Eikeland; Hall-Lord, Marie Louise

    2017-12-02

    Teamwork is an integrated part of today's specialized and complex healthcare and essential to patient safety, and is considered as a core competency to improve twenty-first century healthcare. Teamwork measurements and evaluations show promising results to promote good team performance, and are recommended for identifying areas for improvement. The validated TeamSTEPPS® Teamwork Perception Questionnaire (T-TPQ) was found suitable for cross-cultural validation and testing in a Norwegian context. T-TPQ is a self-report survey that examines five dimensions of perception of teamwork within healthcare settings. The aim of the study was to translate and cross-validate the T-TPQ into Norwegian, and test the questionnaire for psychometric properties among healthcare personnel. The T-TPQ was translated and adapted to a Norwegian context according to a model of a back-translation process. A total of 247 healthcare personnel representing different professionals and hospital settings responded to the questionnaire. A confirmatory factor analysis was carried out to test the factor structure. Cronbach's alpha was used to establish internal consistency, and an Intraclass Correlation Coefficient was used to assess the test - retest reliability. A confirmatory factor analysis showed an acceptable fitting model (χ 2 (df) 969.46 (546), p teamwork dimension clearly represents that specific construct. The Cronbach's alpha demonstrated acceptable values on the five subscales (0.786-0.844), and test-retest showed a reliability parameter, with Intraclass Correlation Coefficient scores from 0.672 to 0.852. The Norwegian version of T-TPQ was considered to be acceptable regarding the validity and reliability for measuring Norwegian individual healthcare personnel's perception of group level teamwork within their unit. However, it needs to be further tested, preferably in a larger sample and in different clinical settings.

  5. Accuracy and correlates of maternal recall of birthweight and gestational age

    DEFF Research Database (Denmark)

    Adegboye, A R A; Heitmann, Berit Lilienthal

    2008-01-01

    the two sources was evaluated by mean differences (MD), intraclass correlation coefficient (ICC) and Bland-Altman's plots. The misclassification of the various BW and GA categories were also estimated. MAIN OUTCOME MEASURES: Differences between recalled and registered BW and GA. RESULTS: There was high......OBJECTIVE: To determine the accuracy of maternal recall of children birthweight (BW) and gestational age (GA), using the Danish Medical Birth Register (DBR) as reference and to examine the reliability of recalled BW and its potential correlates. DESIGN: Comparison of data from the DBR...

  6. A test of conformal invariance: Correlation functions on a disk

    International Nuclear Information System (INIS)

    Badke, R.; Rittenberg, V.; Ruegg, H.

    1985-06-01

    Using conformal invariance one can derive the correlation functions of a disk from those in the half-plane. The correlation function in the half-plane is determined by the 'small' conformal invariance up to an unknown function of one variable. By measuring through the Monte Carlo method the correlation function for two different configurations, the unknown function can be eliminated and one obtains a test of conformal invariance. It is shown that the Ising and the three state Potts model pass the test for very small lattices. (orig.)

  7. Intertester reliability of the talk test in a cardiac rehabilitation population

    DEFF Research Database (Denmark)

    Petersen, Annemette Krintel; Maribo, Thomas; Hjortdal, Vibeke Elisabeth

    2013-01-01

    PURPOSE: The validity of the Talk Test (TT) is well documented, but the reliability of the test is not clear. The aim of this study was to assess the absolute and relative intertester reliability of the TT in cardiac patients. METHODS: Cardiac patients (n = 64) who had completed an exercise...... randomized to tests. Workload in watts at the first negative stage of the TT was registered as the test result. Patients and physiotherapists were blinded to test results of the first test. Absolute reliability of the TT was assessed with Bland-Altman plot, standard error of measurement, and minimal...... detectable change. Relative reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Mean difference in peak workload between test and retest was 0.8 W (95% CI: -4.8 to 3.3). Limit of agreement was estimated to be +31/-32 W. Standard error of measurement was 11 W (95% CI: 10...

  8. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    Science.gov (United States)

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  9. The Cross-Correlation and Reshuffling Tests in Discerning Induced Seismicity

    Science.gov (United States)

    Schultz, Ryan; Telesca, Luciano

    2018-05-01

    In recent years, cases of newly emergent induced clusters have increased seismic hazard and risk in locations with social, environmental, and economic consequence. Thus, the need for a quantitative and robust means to discern induced seismicity has become a critical concern. This paper reviews a Matlab-based algorithm designed to quantify the statistical confidence between two time-series datasets. Similar to prior approaches, our method utilizes the cross-correlation to delineate the strength and lag of correlated signals. In addition, use of surrogate reshuffling tests allows for the dynamic testing against statistical confidence intervals of anticipated spurious correlations. We demonstrate the robust nature of our algorithm in a suite of synthetic tests to determine the limits of accurate signal detection in the presence of noise and sub-sampling. Overall, this routine has considerable merit in terms of delineating the strength of correlated signals, one of which includes the discernment of induced seismicity from natural.

  10. Charge correlations as definitive tests of QCD

    International Nuclear Information System (INIS)

    Maxwell, C.J.

    1981-07-01

    Certain weighted charge correlations are defined and it is shown how they can be used to measure properties of the gluon jet in the e + e - 3-jet final state. Properties are suggested which are indicative of the form of the QCD matrix element, the running coupling constant and value of Λ, and hence constitute definitive tests of QCD. The recent near tenfold increase in luminosity at PETRA should make such experimental tests possible in the near future. (author)

  11. Biologic variability and correlation of platelet function testing in healthy dogs.

    Science.gov (United States)

    Blois, Shauna L; Lang, Sean T; Wood, R Darren; Monteith, Gabrielle

    2015-12-01

    Platelet function tests are influenced by biologic variability, including inter-individual (CVG ) and intra-individual (CVI ), as well as analytic (CVA ) variability. Variability in canine platelet function testing is unknown, but if excessive, would make it difficult to interpret serial results. Additionally, the correlation between platelet function tests is poor in people, but not well described in dogs. The aims were to: (1) identify the effect of variation in preanalytic factors (venipuncture, elapsed time until analysis) on platelet function tests; (2) calculate analytic and biologic variability of adenosine diphosphate (ADP) and arachidonic acid (AA)-induced thromboelastograph platelet mapping (TEG-PM), ADP-, AA-, and collagen-induced whole blood platelet aggregometry (WBA), and collagen/ADP and collagen/epinephrine platelet function analysis (PFA-CADP, PFA-CEPI); and (3) determine the correlation between these variables. In this prospective observational trial, platelet function was measured once every 7 days, for 4 consecutive weeks, in 9 healthy dogs. In addition, CBC, TEG-PM, WBA, and PFA were performed. Overall coefficients of variability ranged from 13.3% to 87.8% for the platelet function tests. Biologic variability was highest for AA-induced maximum amplitude generated during TEG-PM (MAAA; CVG = 95.3%, CVI = 60.8%). Use of population-based reference intervals (RI) was determined appropriate only for PFA-CADP (index of individuality = 10.7). There was poor correlation between most platelet function tests. Use of population-based RI appears inappropriate for most platelet function tests, and tests poorly correlate with one another. Future studies on biologic variability and correlation of platelet function tests should be performed in dogs with platelet dysfunction and those treated with antiplatelet therapy. © 2015 American Society for Veterinary Clinical Pathology.

  12. Learning Low-Rank Class-Specific Dictionary and Sparse Intra-Class Variant Dictionary for Face Recognition

    Science.gov (United States)

    Tang, Xin; Feng, Guo-can; Li, Xiao-xin; Cai, Jia-xin

    2015-01-01

    Face recognition is challenging especially when the images from different persons are similar to each other due to variations in illumination, expression, and occlusion. If we have sufficient training images of each person which can span the facial variations of that person under testing conditions, sparse representation based classification (SRC) achieves very promising results. However, in many applications, face recognition often encounters the small sample size problem arising from the small number of available training images for each person. In this paper, we present a novel face recognition framework by utilizing low-rank and sparse error matrix decomposition, and sparse coding techniques (LRSE+SC). Firstly, the low-rank matrix recovery technique is applied to decompose the face images per class into a low-rank matrix and a sparse error matrix. The low-rank matrix of each individual is a class-specific dictionary and it captures the discriminative feature of this individual. The sparse error matrix represents the intra-class variations, such as illumination, expression changes. Secondly, we combine the low-rank part (representative basis) of each person into a supervised dictionary and integrate all the sparse error matrix of each individual into a within-individual variant dictionary which can be applied to represent the possible variations between the testing and training images. Then these two dictionaries are used to code the query image. The within-individual variant dictionary can be shared by all the subjects and only contribute to explain the lighting conditions, expressions, and occlusions of the query image rather than discrimination. At last, a reconstruction-based scheme is adopted for face recognition. Since the within-individual dictionary is introduced, LRSE+SC can handle the problem of the corrupted training data and the situation that not all subjects have enough samples for training. Experimental results show that our method achieves the

  13. Learning Low-Rank Class-Specific Dictionary and Sparse Intra-Class Variant Dictionary for Face Recognition.

    Science.gov (United States)

    Tang, Xin; Feng, Guo-Can; Li, Xiao-Xin; Cai, Jia-Xin

    2015-01-01

    Face recognition is challenging especially when the images from different persons are similar to each other due to variations in illumination, expression, and occlusion. If we have sufficient training images of each person which can span the facial variations of that person under testing conditions, sparse representation based classification (SRC) achieves very promising results. However, in many applications, face recognition often encounters the small sample size problem arising from the small number of available training images for each person. In this paper, we present a novel face recognition framework by utilizing low-rank and sparse error matrix decomposition, and sparse coding techniques (LRSE+SC). Firstly, the low-rank matrix recovery technique is applied to decompose the face images per class into a low-rank matrix and a sparse error matrix. The low-rank matrix of each individual is a class-specific dictionary and it captures the discriminative feature of this individual. The sparse error matrix represents the intra-class variations, such as illumination, expression changes. Secondly, we combine the low-rank part (representative basis) of each person into a supervised dictionary and integrate all the sparse error matrix of each individual into a within-individual variant dictionary which can be applied to represent the possible variations between the testing and training images. Then these two dictionaries are used to code the query image. The within-individual variant dictionary can be shared by all the subjects and only contribute to explain the lighting conditions, expressions, and occlusions of the query image rather than discrimination. At last, a reconstruction-based scheme is adopted for face recognition. Since the within-individual dictionary is introduced, LRSE+SC can handle the problem of the corrupted training data and the situation that not all subjects have enough samples for training. Experimental results show that our method achieves the

  14. Learning Low-Rank Class-Specific Dictionary and Sparse Intra-Class Variant Dictionary for Face Recognition.

    Directory of Open Access Journals (Sweden)

    Xin Tang

    Full Text Available Face recognition is challenging especially when the images from different persons are similar to each other due to variations in illumination, expression, and occlusion. If we have sufficient training images of each person which can span the facial variations of that person under testing conditions, sparse representation based classification (SRC achieves very promising results. However, in many applications, face recognition often encounters the small sample size problem arising from the small number of available training images for each person. In this paper, we present a novel face recognition framework by utilizing low-rank and sparse error matrix decomposition, and sparse coding techniques (LRSE+SC. Firstly, the low-rank matrix recovery technique is applied to decompose the face images per class into a low-rank matrix and a sparse error matrix. The low-rank matrix of each individual is a class-specific dictionary and it captures the discriminative feature of this individual. The sparse error matrix represents the intra-class variations, such as illumination, expression changes. Secondly, we combine the low-rank part (representative basis of each person into a supervised dictionary and integrate all the sparse error matrix of each individual into a within-individual variant dictionary which can be applied to represent the possible variations between the testing and training images. Then these two dictionaries are used to code the query image. The within-individual variant dictionary can be shared by all the subjects and only contribute to explain the lighting conditions, expressions, and occlusions of the query image rather than discrimination. At last, a reconstruction-based scheme is adopted for face recognition. Since the within-individual dictionary is introduced, LRSE+SC can handle the problem of the corrupted training data and the situation that not all subjects have enough samples for training. Experimental results show that our

  15. Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.

    Directory of Open Access Journals (Sweden)

    Yota Uno

    Full Text Available OBJECTIVE: The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. METHODS: The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQ<70 was performed. In addition, stratum-specific likelihood ratios for detection of intellectual disability were calculated. RESULTS: The Cronbach's alpha for the new Tanaka B Intelligence Scale IQ (BIQ was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96. In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9, and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4. Thus, intellectual disability could be ruled out or determined. CONCLUSION: The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.

  16. Development and Validation of the Behavioral Avoidance Test-Back Pain (BAT-Back) for Patients With Chronic Low Back Pain.

    Science.gov (United States)

    Holzapfel, Sebastian; Riecke, Jenny; Rief, Winfried; Schneider, Jessica; Glombiewski, Julia A

    2016-11-01

    Pain-related fear and avoidance of physical activities are central elements of the fear-avoidance model of musculoskeletal pain. Pain-related fear has typically been measured by self-report instruments. In this study, we developed and validated a Behavioral Avoidance Test (BAT) for chronic low back pain (CLBP) patients with the aim of assessing pain-related avoidance behavior by direct observation. The BAT-Back was administered to a group of CLBP patients (N=97) and pain-free controls (N=31). Furthermore, pain, pain-related fear, disability, catastrophizing, and avoidance behavior were measured using self-report instruments. Reliability was assessed with intraclass correlation coefficient and Cronbach α. Validity was assessed by examining correlation and regression analysis. The intraclass correlation coefficient for the BAT-Back avoidance score was r=0.76. Internal consistency was α=0.95. CLBP patients and controls differed significantly on BAT-Back avoidance scores as well as self-report measures. BAT-Back avoidance scores were significantly correlated with scores on each of the self-report measures (rs=0.27 to 0.54). They were not significantly correlated with general anxiety and depression, age, body mass index, and pain duration. The BAT-Back avoidance score was able to capture unique variance in disability after controlling for other variables (eg, pain intensity and pain-related fear). Results indicate that the BAT-Back is a reliable and valid measure of pain-related avoidance behavior. It may be useful for clinicians in tailoring treatments for chronic pain as well as an outcome measure for exposure treatments.

  17. Non-Normality and Testing that a Correlation Equals Zero

    Science.gov (United States)

    Levy, Kenneth J.

    1977-01-01

    The importance of the assumption of normality for testing that a bivariate normal correlation equals zero is examined. Both empirical and theoretical evidence suggest that such tests are robust with respect to violation of the normality assumption. (Author/JKS)

  18. Interrater and Intrarater Reliability of the Balance Computerized Adaptive Test in Patients With Stroke.

    Science.gov (United States)

    Chiang, Hsin-Yu; Lu, Wen-Shian; Yu, Wan-Hui; Hsueh, I-Ping; Hsieh, Ching-Lin

    2018-04-11

    To examine the interrater and intrarater reliability of the Balance Computerized Adaptive Test (Balance CAT) in patients with chronic stroke having a wide range of balance functions. Repeated assessments design (1wk apart). Seven teaching hospitals. A pooled sample (N=102) including 2 independent groups of outpatients (n=50 for the interrater reliability study; n=52 for the intrarater reliability study) with chronic stroke. Not applicable. Balance CAT. For the interrater reliability study, the values of intraclass correlation coefficient, minimal detectable change (MDC), and percentage of MDC (MDC%) for the Balance CAT were .84, 1.90, and 31.0%, respectively. For the intrarater reliability study, the values of intraclass correlation coefficient, MDC, and MDC% ranged from .89 to .91, from 1.14 to 1.26, and from 17.1% to 18.6%, respectively. The Balance CAT showed sufficient intrarater reliability in patients with chronic stroke having balance functions ranging from sitting with support to independent walking. Although the Balance CAT may have good interrater reliability, we found substantial random measurement error between different raters. Accordingly, if the Balance CAT is used as an outcome measure in clinical or research settings, same raters are suggested over different time points to ensure reliable assessments. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Reliability and Validity of a New Test of Change-of-Direction Speed for Field-Based Sports: the Change-of-Direction and Acceleration Test (CODAT).

    Science.gov (United States)

    Lockie, Robert G; Schultz, Adrian B; Callaghan, Samuel J; Jeffriess, Matthew D; Berry, Simon P

    2013-01-01

    Field sport coaches must use reliable and valid tests to assess change-of-direction speed in their athletes. Few tests feature linear sprinting with acute change- of-direction maneuvers. The Change-of-Direction and Acceleration Test (CODAT) was designed to assess field sport change-of-direction speed, and includes a linear 5-meter (m) sprint, 45° and 90° cuts, 3- m sprints to the left and right, and a linear 10-m sprint. This study analyzed the reliability and validity of this test, through comparisons to 20-m sprint (0-5, 0-10, 0-20 m intervals) and Illinois agility run (IAR) performance. Eighteen Australian footballers (age = 23.83 ± 7.04 yrs; height = 1.79 ± 0.06 m; mass = 85.36 ± 13.21 kg) were recruited. Following familiarization, subjects completed the 20-m sprint, CODAT, and IAR in 2 sessions, 48 hours apart. Intra-class correlation coefficients (ICC) assessed relative reliability. Absolute reliability was analyzed through paired samples t-tests (p ≤ 0.05) determining between-session differences. Typical error (TE), coefficient of variation (CV), and differences between the TE and smallest worthwhile change (SWC), also assessed absolute reliability and test usefulness. For the validity analysis, Pearson's correlations (p ≤ 0.05) analyzed between-test relationships. Results showed no between-session differences for any test (p = 0.19-0.86). CODAT time averaged ~6 s, and the ICC and CV equaled 0.84 and 3.0%, respectively. The homogeneous sample of Australian footballers meant that the CODAT's TE (0.19 s) exceeded the usual 0.2 x standard deviation (SD) SWC (0.10 s). However, the CODAT is capable of detecting moderate performance changes (SWC calculated as 0.5 x SD = 0.25 s). There was a near perfect correlation between the CODAT and IAR (r = 0.92), and very large correlations with the 20-m sprint (r = 0.75-0.76), suggesting that the CODAT was a valid change-of-direction speed test. Due to movement specificity, the CODAT has value for field sport

  20. Balance Assessment in Sports-Related Concussion: Evaluating Test-Retest Reliability of the Equilibrate System.

    Science.gov (United States)

    Odom, Mitchell J; Lee, Young M; Zuckerman, Scott L; Apple, Rachel P; Germanos, Theodore; Solomon, Gary S; Sills, Allen K

    2016-01-01

    This study evaluated the test-retest reliability of a novel computer-based, portable balance assessment tool, the Equilibrate System (ES), used to diagnose sports-related concussion. Twenty-seven students participated in ES testing consisting of three sessions over 4 weeks. The modified Balance Error Scoring System was performed. For each participant, test-retest reliability was established using the intraclass correlation coefficient (ICC). The ES test-retest reliability from baseline to week 2 produced an ICC value of 0.495 (95% CI, 0.123-0.745). Week 2 testing produced ICC values of 0.602 (95% CI, 0.279-0.803) and 0.610 (95% CI, 0.299-0.804), respectively. All other single measures test-retest reliability values produced poor ICC values. Same-day ES testing showed fair to good test-retest reliability while interweek measures displayed poor to fair test-retest reliability. Testing conditions should be controlled when using computerized balance assessment methods. ES testing should only be used as a part of a comprehensive assessment.

  1. The Leeb Hardness Test for Rock: An Updated Methodology and UCS Correlation

    Science.gov (United States)

    Corkum, A. G.; Asiri, Y.; El Naggar, H.; Kinakin, D.

    2018-03-01

    The Leeb hardness test (LHT with test value of L D ) is a rebound hardness test, originally developed for metals, that has been correlated with the Unconfined Compressive Strength (test value of σ c ) of rock by several authors. The tests can be carried out rapidly, conveniently and nondestructively on core and block samples or on rock outcrops. This makes the relatively small LHT device convenient for field tests. The present study compiles test data from literature sources and presents new laboratory testing carried out by the authors to develop a substantially expanded database with wide-ranging rock types. In addition, the number of impacts that should be averaged to comprise a "test result" was revisited along with the issue of test specimen size. Correlation for L D and σ c for various rock types is provided along with recommended testing methodology. The accuracy of correlated σ c estimates was assessed and reasonable correlations were observed between L D and σ c . The study findings show that LHT can be useful particularly for field estimation of σ c and offers a significant improvement over the conventional field estimation methods outlined by the ISRM (e.g., hammer blows). This test is rapid and simple, with relatively low equipment costs, and provides a reasonably accurate estimate of σ c .

  2. A study on stress analysis of small punch-creep test and its experimental correlations with uniaxial-creep test

    International Nuclear Information System (INIS)

    Lee, Song In; Baek, Seoung Se; Kwon, Il Hyun; Yu, Hyo Sun

    2002-01-01

    A basic research was performed to ensure the usefulness of Small Punch-creep(SP-creep) test for residual life evaluation of heat resistant components effectively. This paper presents analytical results of initial stress and strain distributions in SP specimen caused by constant loading for SP-creep test and its experimental correlations with uniaxial creep(Ten-creep) test on 9CrlMoVNb steel. It was shown that the initial maximum equivalent stress, σ eq · max from FE analysis was correlated with steady-state equivalent creep strain rate, ε qf-ss , rupture time, t r , activation energy, Q and Larson-Miller parameter, LMP during SP-creep deformation. The simple correlation laws, σ SP - σ TEN , P SP -σ TEN and Q SP -Q TEN adopted to established a quantitative correlation between SP-creep and Ten-creep test data. Especially, the activation energy obtained from SP-creep test is linearly related to that from Ten-creep test at 650 deg. C as follows : Q SP-P =1.37 Q TEN , Q SP-σ =1.53 Q TEN

  3. Statistical tests for power-law cross-correlated processes

    Science.gov (United States)

    Podobnik, Boris; Jiang, Zhi-Qiang; Zhou, Wei-Xing; Stanley, H. Eugene

    2011-12-01

    For stationary time series, the cross-covariance and the cross-correlation as functions of time lag n serve to quantify the similarity of two time series. The latter measure is also used to assess whether the cross-correlations are statistically significant. For nonstationary time series, the analogous measures are detrended cross-correlations analysis (DCCA) and the recently proposed detrended cross-correlation coefficient, ρDCCA(T,n), where T is the total length of the time series and n the window size. For ρDCCA(T,n), we numerically calculated the Cauchy inequality -1≤ρDCCA(T,n)≤1. Here we derive -1≤ρDCCA(T,n)≤1 for a standard variance-covariance approach and for a detrending approach. For overlapping windows, we find the range of ρDCCA within which the cross-correlations become statistically significant. For overlapping windows we numerically determine—and for nonoverlapping windows we derive—that the standard deviation of ρDCCA(T,n) tends with increasing T to 1/T. Using ρDCCA(T,n) we show that the Chinese financial market's tendency to follow the U.S. market is extremely weak. We also propose an additional statistical test that can be used to quantify the existence of cross-correlations between two power-law correlated time series.

  4. Correlations of Platooning Track Test and Wind Tunnel Data

    Energy Technology Data Exchange (ETDEWEB)

    Lammert, Michael P. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Kelly, Kenneth J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Yanowitz, Janet [Ecoengineering, Sharonville, OH (United States)

    2018-02-02

    In this report, the National Renewable Energy Laboratory analyzed results from multiple, independent truck platooning projects to compare and contrast track test results with wind tunnel test results conducted by Lawrence Livermore National Laboratory (LLNL). Some highlights from the report include compiled data, and results from four independent SAE J1321 full-size track test campaigns that were compared to LLNL wind tunnel testing results. All platooning scenarios tested demonstrated significant fuel savings with good correlation relative to following distances, but there are still unanswered questions and clear opportunities for system optimization. NOx emissions showed improvements from NREL tests in 2014 to Auburn tests in 2015 with respect to J1321 platooning track testing of Peloton system. NREL evaluated data from Volpe's Naturalistic Study of Truck Following Behavior, which showed minimal impact of naturalistic background platooning. We found significant correlation between multiple track studies, wind tunnel tests, and computational fluid dynamics, but also showed that there is more to learn regarding close formation and longer-distance effects. We also identified potential areas for further research and development, including development of advanced aerodynamic designs optimized for platooning, measurement of platoon system performance in traffic conditions, impact of vehicle lateral offsets on platooning performance, and characterization of the national potential for platooning based on fleet operational characteristics.

  5. Thermal Testing and Model Correlation for Advanced Topographic Laser Altimeter Instrument (ATLAS)

    Science.gov (United States)

    Patel, Deepak

    2016-01-01

    The Advanced Topographic Laser Altimeter System (ATLAS) part of the Ice Cloud and Land Elevation Satellite 2 (ICESat-2) is an upcoming Earth Science mission focusing on the effects of climate change. The flight instrument passed all environmental testing at GSFC (Goddard Space Flight Center) and is now ready to be shipped to the spacecraft vendor for integration and testing. This topic covers the analysis leading up to the test setup for ATLAS thermal testing as well as model correlation to flight predictions. Test setup analysis section will include areas where ATLAS could not meet flight like conditions and what were the limitations. Model correlation section will walk through changes that had to be made to the thermal model in order to match test results. The correlated model will then be integrated with spacecraft model for on-orbit predictions.

  6. Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

    Science.gov (United States)

    Kim, Jong S.; Teti, Nicholas M.

    2015-01-01

    The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error

  7. Correlation Based Testing for Passive Sonar Picture Rationalization

    National Research Council Canada - National Science Library

    Mellema, Garfield R

    2007-01-01

    .... The sample correlation coefficient, is a statistical measure of relatedness. This paper describes the application of a test based on that measure to compare tracks produced by a probabilistic data association filter from a set of towed array sonar data. Keywords.

  8. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    Science.gov (United States)

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  9. Scapular dyskinesis in trapezius myalgia and intraexaminer reproducibility of clinical tests

    DEFF Research Database (Denmark)

    Juul-Kristensen, Birgit; Hilt, Kenneth; Enoch, Flemming

    2011-01-01

    dyskinesis, general health, and work ability, and 19 cases and 14 controls participated in the reproducibility study. Intraexaminer reproducibility was good to excellent for 6 of 10 clinical variables (Intraclass Correlation Coefficient [ICC] 0.76-0.91; kappa 0.84-1.00), and fair to good for four variables...

  10. HIV Testing in Recent College Students: Prevalence and Correlates

    Science.gov (United States)

    Caldeira, Kimberly M.; Singer, Barbara J.; O'Grady, Kevin E.; Vincent, Kathryn B.; Arria, Amelia M.

    2012-01-01

    Prevalence and correlates of HIV testing were examined in a sample of 957 unmarried recent college students in the United States. Participants were asked about HIV testing, past-six-months sexual activities, lifetime treatment for sexually transmitted infections (STI), past-year health service utilization, and DSM-IV criteria for alcohol and other…

  11. A Computer-Based Sustained Visual Attention Test for Pre-School Children: Design, Development and Psychometric Properties

    Directory of Open Access Journals (Sweden)

    Roohollah Zahedian Nasb

    2016-06-01

    Full Text Available Background: Sustained visual attention is a prerequisite for learning and memory. The early evaluation of attention in childhood is essential for their school and career success in the future. The aim of this study was to design, development and investigation of psychometric properties (content, face and convergent validity and test-retest and internal consistency reliability of the computer - based sustained visual attention test (SuVAT for healthy preschool children aged 4-6 with their special needs. Methods: This study was carried out in two stages: in the first stage computerbased SuVAT in two versions original and parallel were developed. Then the test-retest and internal consistency reliability using intra-class correlation and Cronbach’s alpha coefficients respectively were examined; Face validity was calculated through ideas gathering from 10 preschool children and content validity evaluated using CVI and CVR method and convergent validity of SuVAT with CPT was assessed using Pearson correlation. Results: The developed test showed a good content and faces validity, and also had excellent test-retest reliability. In addition, the assessment of internal consistency indicated the high internal consistency of the test (Cronbach’s alpha=0.869. SuVAT and CPT test demonstrated a positive correlation upon the convergent validity testing. Conclusion: SuVAT with good reliability and validity could be used as an acceptable sustained attention assessment in preschool children.

  12. Psychometric testing of the modified Care Dependency Scale (Neuro-CDS).

    Science.gov (United States)

    Piredda, Michela; Biagioli, Valentina; Gambale, Giulia; Porcelli, Elisa; Barbaranelli, Claudio; Palese, Alvisa; De Marinis, Maria Grazia

    2016-01-01

    Effective measures of nursing care dependency in neurorehabilitation are warranted to plan nursing interventions to help patients avoid increasing dependency. The Care Dependency Scale (CDS) is a theory-based, comprehensive tool to evaluate functional disability. This study aimed to modify the CDS for neurological and neurorehabilitation patients (Neuro-CDS) and to test its psychometric properties in adult neurorehabilitation inpatients. Exploratory factor analysis (EFA) was performed using a Maximum Likelihood robust (MLR) estimator. The Barthel Index (BI) was used to evaluate concurrent validity. Stability was measured using the Intra-class Correlation Coefficient (ICC). The sample included 124 patients (mean age = 69.7 years, 54% male). The EFA revealed a two-factor structure with good fit indexes, Factor 1 (Physical care dependence) loaded by 11 items and Factor 2 (Psycho-social care dependence) loaded by 4 items. The correlation between factors was 0.61. Correlations between Factor 1 and the BI and between Factor 2 and the BI were r = 0.843 and r = 0.677, respectively (p dependence in neurorehabilitation patients as a basis for individualized and holistic care.

  13. Estimate of uncertainties correlated and no correlated associated to performance tests of activity meters

    International Nuclear Information System (INIS)

    Sousa, C.H.S.; Teixeira, G.J.; Peixoto, J.G.P.

    2014-01-01

    Activimeters should undergo performance for verifying the functionality tests as technical recommendations. This study estimated the associated expanded uncertainties uncorrelated to the results conducted on three instruments, two detectors with ionization chamber and one with Geiger Mueller tubes. For this we used a standard reference source and screened certified by the National Institute of Technology and Standardization. The methodology of this research was based on the protocols listed in the technical document of the International Atomic Energy Agency. Later two quantities were correlated presenting real correlation and improving expanded uncertainty 3.7%. (author)

  14. Using Response Surface Methods to Correlate the Modal Test of an Inflatable Test Article

    Science.gov (United States)

    Gupta, Anju

    2013-01-01

    This paper presents a practical application of response surface methods (RSM) to correlate a finite element model of a structural modal test. The test article is a quasi-cylindrical inflatable structure which primarily consists of a fabric weave, with an internal bladder and metallic bulkheads on either end. To mitigate model size, the fabric weave was simplified by representing it with shell elements. The task at hand is to represent the material behavior of the weave. The success of the model correlation is measured by comparing the four major modal frequencies of the analysis model to the four major modal frequencies of the test article. Given that only individual strap material properties were provided and material properties of the overall weave were not available, defining the material properties of the finite element model became very complex. First it was necessary to determine which material properties (modulus of elasticity in the hoop and longitudinal directions, shear modulus, Poisson's ratio, etc.) affected the modal frequencies. Then a Latin Hypercube of the parameter space was created to form an efficiently distributed finite case set. Each case was then analyzed with the results input into RSM. In the resulting response surface it was possible to see how each material parameter affected the modal frequencies of the analysis model. If the modal frequencies of the analysis model and its corresponding parameters match the test with acceptable accuracy, it can be said that the model correlation is successful.

  15. A near infrared spectroscopy-based test of calf muscle function in patients with peripheral arterial disease

    DEFF Research Database (Denmark)

    Pedersen, Brian Lindegaard; Bækgaard, Niels; Quistorff, Bjørn

    2015-01-01

    test runs. Intraclass correlation constant (ICC) was used to describe reproducibility. The ICC was calculated using the area under the NIRS oxygenated hemoglobin (Hbox) curve, the initial velocity of the Hbox recovery curve, force measurements, and walking time. Results The ICC of the GAS was between 0...... and two age-matched patients without claudication. Each patient was tested with an isometric ergometer pedal test and a treadmill test applying NIRS measurements of the anterior tibial and the gastrocnemius muscles (GAS). Tests were repeated three times with randomly selected intervals between individual.......92-0.95 (foot-pedal) and 0.70-0.98 (tread mill) and of the anterior tibial muscle was between 0.87-0.96 (foot-pedal) and 0.67-0.79 (tread mill). Conclusion In this study, we contribute a new apparatus and test protocol for peripheral arterial disease (PAD) applying NIRS technique and controlled physical...

  16. Non-invasive assessment of kidney allograft fibrosis with shear wave elastography: A radiological-pathological correlation analysis.

    Science.gov (United States)

    Ma, Maggie Km; Law, Helen Kw; Tse, Kin Sun; Chan, Kwok Wah; Chan, Gary Cw; Yap, Desmond Yh; Mok, Maggie My; Kwan, Lorraine Py; Tang, Sydney Cw; Choy, Bo Ying; Chan, Tak Mao

    2018-02-14

    To evaluate the use of shear wave elastography in assessment of kidney allograft tubulointerstitial fibrosis. Shear wave elastography assessment was carried out by two independent operators in kidney transplant recipients who underwent allograft biopsy for clinical indications (i.e. rising creatinine >15% or proteinuria >1 g/day). Allograft biopsies were interpreted by the same pathologist according to the 2013 Banff Classification. A total of 40 elastography scans were carried out (median creatinine 172.5 μmol/L [interquartile range 133.8-281.8 μmol/L]). Median tissue stiffness at the cortex (22.6 kPa [interquartile range 18.8-25.7 kPa] vs 22.3 kPa [interquartile range 19.0-26.5 kPa], P = 0.70) and medulla (15.0 kPa [interquartile range 13.7-18.0 kPa] vs 15.6 kPa [interquartile range 14.4-18.2 kPa]) showed no significant differences between the two observers. Interobserver agreement was satisfactory (intraclass correlation coefficient of the cortex 0.84, 95% CI 0.70-0.92 and intraclass correlation coefficient of the medulla 0.88, 95% CI 0.78-0.94). The areas under the receiver operating characteristic curves for detection of tubulointerstitial fibrosis were estimated to be 0.75 (95% CI 0.61-0.89), 0.85 (95% CI 0.75-0.95) and 0.65 (95% CI 0.53-0.78) for cortical, medullary tissue stiffness and serum creatinine, respectively. Shear wave elastography can be used as a non-invasive tool to evaluate kidney allograft fibrosis with reasonable interobserver agreement and superior test performance to serum creatinine in detecting early tubulointerstitial fibrosis. © 2018 The Japanese Urological Association.

  17. Test-retest reliability, smallest real difference and concurrent validity of six different balance tests on young people with mild to moderate intellectual disability.

    Science.gov (United States)

    Blomqvist, Sven; Wester, Anita; Sundelin, Gunnevi; Rehn, Börje

    2012-12-01

    Some studies have reported that people with intellectual disability may have reduced balance ability compared with the population in general. However, none of these studies involved adolescents, and the reliability and validity of balance tests in this population are not known. The purpose of this study was to examine the reliability of six different balance tests and to investigate their concurrent validity. Test-retest reliability assessment. All subjects were recruited from a special school for people with intellectual disability in Bollnäs, Sweden. Eighty-nine adolescents (35 females and 54 males) with mild to moderate intellectual disability with a mean age of 18 years (range 16 to 20 years). All subjects followed the same test protocol on two occasions within an 11-day period. Balance test performances. Intraclass correlation coefficients greater than 0.80 were achieved for four of the balance tests: Extended Timed Up and Go Test, Modified Functional Reach Test, One-leg Stance Test and Force Platform Test. The smallest real differences ranged from 12% to 40%; less than 20% is considered to be low. Concurrent validity among these balance tests varied between no and low correlation. The results indicate that these tests could be used to evaluate changes in balance ability over time in people with mild to moderate intellectual disability. The low concurrent validity illustrates the importance of knowing more about the influence of various sensory subsystems that are significant for balance among adolescents with intellectual disability. Copyright © 2011 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  18. On the problem of nonsense correlations in allergological tests after routine extraction.

    Science.gov (United States)

    Rijckaert, G

    1981-01-01

    The influence of extraction procedures and culturing methods of material used for the preparation of allergenic extracts on correlation patterns found in allergological testing (skin test and RAST) was investigated. In our laboratory a short extraction procedure performed at O degrees C was used for Aspergillus repens. A. penicilloides, Wallemia sebi, their rearing media and non-inoculated medium. For the commercially available extracts from house dust, house-dust mite, pollen of Dactylus glomerata and A. penicilloides a longer procedure (several days) performed at room temperature was used. Statistical analysis showed a separation of all test results into two clusters, each cluster being composed of correlations between extracts from only one the manufacturers did not show any correlation. The correlations found between the short time incubated extracts of the xerophilic fungi and their rearing media could be explained by genetical and biochemical relationships between these fungi depending on ecological conditions. However, while the correlation found between house dust and house-dust mite is understandable, correlations found between long time incubated extracts from house-dust mite and D. glomerata or A. penicilloides may be nonsense correlations, that do not adequately describe the in vivo situation. The similarity of these extracts is presumably artificially created during extraction.

  19. Correlation between thromboelastography and traditional coagulation test parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Rubanick JV

    2017-02-01

    Full Text Available Jean V Rubanick, Medora B Pashmakova, Micah A Bishop, James W Barr Department of Veterinary Small Animal Clinical Sciences, Texas A&M University, College Station, TX, USA Abstract: A hospital-based, prospective cross-sectional study was used to compare kaolin-activated thromboelastography (TEG parameters with traditional coagulation tests in 29 hospitalized dogs. Cases were included if the attending clinician requested coagulation testing. Blood was obtained from each dog and coagulation (prothrombin time, partial thromboplastin time, antithrombin activity, d-dimer concentration, and fibrinogen concentration and TEG analyses were performed. Hematocrit (Hct was also measured. Traditional coagulation results were evaluated for correlation with those from kaolin-activated TEG. Spearman’s correlation was used to calculate correlation coefficients. Fibrinogen was positively correlated with maximum amplitude (Pearson r=0.72, P<0.001 and global clot strength (Pearson r=0.72, P<0.001. There was no correlation between any of the remaining coagulation variables, TEG parameters, or Hct. Results of kaolin-activated TEG and traditional coagulation tests are not interchangeable means of monitoring coagulation derangements in this intensive care unit patient population. Determination of a true outcome measure is necessary to establish TEG’s clinical relevance to veterinary medicine. Keywords: TEG, thromboelastography, coagulation, hemostasis

  20. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    Science.gov (United States)

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  1. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    Science.gov (United States)

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing

  2. Maximal cardiorespiratory fitness testing in individuals with chronic stroke with cognitive impairment: practice test effects and test-retest reliability.

    Science.gov (United States)

    Olivier, Charles; Doré, Jean; Blanchet, Sophie; Brooks, Dina; Richards, Carol L; Martel, Guy; Robitaille, Nancy-Michelle; Maltais, Désirée B

    2013-11-01

    To evaluate, for individuals with chronic stroke with cognitive impairment, (1) the effects of a practice test on peak cardiorespiratory fitness test results; (2) cardiorespiratory fitness test-retest reliability; and (3) the relationship between individual practice test effects and cognitive impairment. Cross-sectional. Rehabilitation center. A convenience sample of 21 persons (men [n=12] and women [n=9]; age range, 48-81y; 44.9±36.2mo poststroke) with cognitive impairments who had sufficient lower limb function to perform the test. Not applicable. Peak oxygen consumption (Vo(2)peak, ml·kg(-1)·min(-1)). Test-retest reliability of Vo(2)peak was excellent (intraclass correlation coefficient model 2,1 [ICC2,1]=.94; 95% confidence interval [CI], .86-.98). A paired t test showed that there was no significant difference for the group for Vo(2)peak obtained from 2 symptom-limited cardiorespiratory fitness tests performed 1 week apart on a semirecumbent cycle ergometer (test 2-test 1 difference, -.32ml·kg(-1)·min(-1); 95% CI, -.69 to 1.33ml·kg(-1)·min(-1); P=.512). Individual test-retest differences in Vo(2)peak were, however, positively related to general cognitive function as measured by the Mini-Mental State Examination (ρ=.485; Preliably measured in this group without a practice test. General cognitive function, however, may influence the effect of a practice test in that those with lower general cognitive function appear to respond differently to a practice test than those with higher cognitive function. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  3. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  4. Correlations between cerebral glucose metabolism and neuropsychological test performance in nonalcoholic cirrhotics.

    Science.gov (United States)

    Lockwood, Alan H; Weissenborn, Karin; Bokemeyer, Martin; Tietge, U; Burchert, Wolfgang

    2002-03-01

    Many cirrhotics have abnormal neuropsychological test scores. To define the anatomical-physiological basis for encephalopathy in nonalcoholic cirrhotics, we performed resting-state fluorodeoxyglucose positron emission tomographic scans and administered a neuropsychological test battery to 18 patients and 10 controls. Statistical parametric mapping correlated changes in regional glucose metabolism with performance on the individual tests and a composite battery score. In patients without overt encephalopathy, poor performance correlated with reductions in metabolism in the anterior cingulate. In all patients, poor performance on the battery was positively correlated (p glucose metabolism in bifrontal and biparietal regions of the cerebral cortex and negatively correlated with metabolism in hippocampal, lingual, and fusiform gyri and the posterior putamen. Similar patterns of abnormal metabolism were found when comparing the patients to 10 controls. Metabolic abnormalities in the anterior attention system and association cortices mediating executive and integrative function form the pathophysiological basis for mild hepatic encephalopathy.

  5. Correlation between two parameters of mice behaviour in the open field test

    OpenAIRE

    Stojanović, Nikola M.; Ranđelović, Pavle J.; Radulović, Niko S.

    2017-01-01

    The open field test is being used extensively for the determination of different aspects of animal behaviour for over seventy years. The correlation between different behavioural parameters obtained in this test, although previously studied, is still debatable. Thus, we aimed to analyze and correlate behaviour scores to estimate the importance of individual parameters in this type of experiment. The open field test was performed on male BALB/c mice treated with either saline (10 ml/kg) or dia...

  6. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing - Part 2

    Science.gov (United States)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerome C.; Kolody, Mark R.

    2012-01-01

    Evaluation of metals to predict service life of metal-based structures in corrosive environments has long relied on atmospheric exposure test sites. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions similar to those of the corrosive environment. Their reliability to correlate to atmospheric exposure test results is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated corrosion testing has yet to be universally accepted as a useful tool in predicting the long-term service life of a metal, despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard, and their use is crucial, a method that correlates timescales from accelerated testing to atmospheric exposure would be very valuable. This paper presents work that began with the characterization of the atmospheric environment at the Kennedy Space Center (KSC) Beachside Corrosion Test Site. The chemical changes that occur on low carbon steel, during atmospheric and accelerated corrosion conditions, were investigated using surface chemistry analytical methods. The corrosion rates and behaviors of panels subjected to long-term and accelerated corrosion conditions, involving neutral salt fog and alternating seawater spray, were compared to identify possible timescale correlations between accelerated and long-term corrosion performance. The results, as well as preliminary findings on the correlation investigation, are presented.

  7. Taking serial correlation into account in tests of the mean

    International Nuclear Information System (INIS)

    Zwiers, F.W.; Storch, H. von

    1993-01-01

    The comparison of means derived from samples of noisy data is a standard part of climatology. When the data are not serially correlated the appropriate statistical tool for this task is usually the conventional Student's t-test. However, data frequently are serially correlated in climatological applications with the result that the t-tests in its standard form is not applicable. The usual solution to this problem is to scale the t-statistic by a factor which depends upon the equivalent sample size n e . We show, by means of simulations, that the revised t-test is often conservative (the actual significance level is smaller than the specified significance level) when the equivalent sample size is known. However, in most practical cases the equivalent sample size is not known. Then the test becomes liberal (the actual significance level is greater than the specified significance level). This systematic error becomes small when the true equivalent sample size is large (greater than approximately 30). We re-examine the difficulties inherent in difference of means tests when there is serial dependence. We provide guidelines for the application of the 'usual' t-test and propose two alternative tests which substantially improve upon the 'usual' t-test when samples are small. (orig.)

  8. Correlation of alluvial deposits at the Nevada Test Site

    International Nuclear Information System (INIS)

    Grothaus, B.; Howard, N.

    1977-01-01

    Because characteristics of rock layers and problems in drilling must be studied before radioactive waste can be safely contained, an evaluation was made of methods for correlating alluvial deposits at Yucca Flat of the Nevada Test Site (NTS). Although correlation of Tertiary volcanic tuff beds at the NTS has been successfully achieved, correlation of stratigraphic zones in the overlying alluvium has posed technical difficulties. We have evaluated several methods for correlating alluvial deposits from drillholes, including electric resistivity logs (E logs), visual examination of sidewall samples and comparison of their carbonate (CO 2 ) content, downhole stereo photography for identifying debris flow deposits, caliche age-dating, and specific yield and permeability measurements of deposits. For predicting the thickness of zones having similar physical properties in the alluvium, E log measurements were found to be the most useful of these methods

  9. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  10. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  11. Validity and reliability of wii fit balance board for the assessment of balance of healthy young adults and the elderly.

    Science.gov (United States)

    Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen

    2013-10-01

    [Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86-0.99) for the elderly people and positive correlations (r = 0.58-0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability.

  12. Reliability of one-repetition maximum performance in people with chronic heart failure.

    Science.gov (United States)

    Ellis, Rachel; Holland, Anne E; Dodd, Karen; Shields, Nora

    2018-02-24

    Evaluate intra-rater and inter-rater reliability of the one-repetition maximum strength test in people with chronic heart failure. Intra-rater and inter-rater reliability study. A public tertiary hospital in northern metropolitan Melbourne. Twenty-four participants (nine female, mean age 71.8 ± 13.1 years) with mild to moderate heart failure of any aetiology. Lower limb strength was assessed by determining the maximum weight that could be lifted using a leg press. Intra-rater reliability was tested by one assessor on two separate occasions . Inter-rater reliability was tested by two assessors in random order. Intra-class correlation coefficients and 95% confidence intervals were calculated. Bland and Altman analyses were also conducted, including calculation of mean differences between measures ([Formula: see text]) and limits of agreement . Ten intra-rater and 21 inter-rater assessments were completed. Excellent intra-rater (intra-class correlation coefficient 2,1 0.96) and inter-rater (intra-class correlation coefficient 2,1 0.93) reliability was found. Intra-rater assessment showed less variability (mean difference 4.5 kg, limits of agreement -8.11 to 17.11 kg) than inter-rater agreement (mean difference -3.81 kg, limits of agreement -23.39 to 15.77 kg). One-repetition maximum determined using a leg press is a reliable measure in people with heart failure. Given its smaller limits of agreement, intra-rater testing is recommended. Implications for Rehabilitation Using a leg press to determine a one-repetition maximum we were able to demonstrate excellent inter-rater and intra-rater reliability using an intra-class correlation coefficient. The Bland and Altman levels of agreement were wide for inter-rater reliability and so we recommend using one assessor if measuring change in strength within an individual over time.

  13. Face validity and reliability of a pictorial instrument for assessing fundamental movement skill perceived competence in young children.

    Science.gov (United States)

    Barnett, Lisa M; Ridgers, Nicola D; Zask, Avigdor; Salmon, Jo

    2015-01-01

    To determine reliability and face validity of an instrument to assess young children's perceived fundamental movement skill competence. Validation and reliability study. A pictorial instrument based on the Test Gross Motor Development-2 assessed perceived locomotor (six skills) and object control (six skills) competence using the format and item structure from the physical competence subscale of the Pictorial Scale of Perceived Competence and Acceptance for Young Children. Sample 1 completed object control items in May (n=32) and locomotor items in October 2012 (n=23) at two time points seven days apart. Children were asked at the end of the test-retest their understanding of what was happening in each picture to determine face validity. Sample 2 (n=58) completed 12 items in November 2012 on a single occasion to test internal reliability only. Sample 1 children were aged 5-7 years (M=6.0, SD=0.8) at object control assessment and 5-8 years at locomotor assessment (M=6.5, SD=0.9). Sample 2 children were aged 6-8 years (M=7.2, SD=0.73). Intra-class correlations assessed in Sample 1 children were excellent for object control (intra-class correlation=0.78), locomotor (intra-class correlation=0.82) and all 12 skills (intra-class correlations=0.83). Face validity was acceptable. Internal consistency was adequate in both samples for each subscale and all 12 skills (alpha range 0.60-0.81). This study has provided preliminary evidence for instrument reliability and face validity. This enables future alignment between the measurement of perceived and actual fundamental movement skill competence in young children. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  14. REPRODUCIBILITY OF THE MODIFIED STAR EXCURSION BALANCE TEST COMPOSITE AND SPECIFIC REACH DIRECTION SCORES.

    Science.gov (United States)

    van Lieshout, Remko; Reijneveld, Elja A E; van den Berg, Sandra M; Haerkens, Gijs M; Koenders, Niek H; de Leeuw, Arina J; van Oorsouw, Roel G; Paap, Davy; Scheffer, Else; Weterings, Stijn; Stukstette, Mirelle J

    2016-06-01

    The mSEBT is a screening tool used to evaluate dynamic balance. Most research investigating measurement properties focused on intrarater reliability and was done in small samples. To know whether the mSEBT is useful to discriminate dynamic balance between persons and to evaluate changes in dynamic balance, more research into intra- and interrater reliability and smallest detectable change (synonymous with minimal detectable change) is needed. To estimate intra- and interrater reliability and smallest detectable change of the mSEBT in adults at risk for ankle sprain. Cross-sectional, test-retest design. Fifty-five healthy young adults participating in sports at risk for ankle sprain participated (mean ± SD age, 24.0 ± 2.9 years). Each participant performed three test sessions within one hour and was rated by two physical therapists (session 1, rater 1; session 2, rater 2; session 3, rater 1). Participants and raters were blinded for previous measurements. Normalized composite and reach direction scores for the right and left leg were collected. Analysis of variance was used to calculate intraclass correlation coefficient values for intra- and interrater reliability. Smallest detectable change values were calculated based on the standard error of measurement. Intra- and interrater reliability for both legs was good to excellent (intraclass correlation coefficient ranging from 0.87 to 0.94). The intrarater smallest detectable change for the composite score of the right leg was 7.2% and for the left 6.2%. The interrater smallest detectable change for the composite score of the right leg was 6.9% and for the left 5.0%. The mSEBT is a reliable measurement instrument to discriminate dynamic balance between persons. Most smallest detectable change values of the mSEBT appear to be large. More research is needed to investigate if the mSEBT is usable for evaluative purposes. Level 2.

  15. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    Science.gov (United States)

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  16. Pearson's chi-square test and rank correlation inferences for clustered data.

    Science.gov (United States)

    Shih, Joanna H; Fay, Michael P

    2017-09-01

    Pearson's chi-square test has been widely used in testing for association between two categorical responses. Spearman rank correlation and Kendall's tau are often used for measuring and testing association between two continuous or ordered categorical responses. However, the established statistical properties of these tests are only valid when each pair of responses are independent, where each sampling unit has only one pair of responses. When each sampling unit consists of a cluster of paired responses, the assumption of independent pairs is violated. In this article, we apply the within-cluster resampling technique to U-statistics to form new tests and rank-based correlation estimators for possibly tied clustered data. We develop large sample properties of the new proposed tests and estimators and evaluate their performance by simulations. The proposed methods are applied to a data set collected from a PET/CT imaging study for illustration. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  17. The effect of repeated measurements and working memory on the most comfortable level in the ANL test

    DEFF Research Database (Denmark)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas

    2014-01-01

    interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. STUDY SAMPLE: Thirty-two normal-hearing adults. RESULTS: Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used...

  18. Testing general relativity at cosmological scales: Implementation and parameter correlations

    International Nuclear Information System (INIS)

    Dossett, Jason N.; Ishak, Mustapha; Moldenhauer, Jacob

    2011-01-01

    The testing of general relativity at cosmological scales has become a possible and timely endeavor that is not only motivated by the pressing question of cosmic acceleration but also by the proposals of some extensions to general relativity that would manifest themselves at large scales of distance. We analyze here correlations between modified gravity growth parameters and some core cosmological parameters using the latest cosmological data sets including the refined Cosmic Evolution Survey 3D weak lensing. We provide the parametrized modified growth equations and their evolution. We implement known functional and binning approaches, and propose a new hybrid approach to evolve the modified gravity parameters in redshift (time) and scale. The hybrid parametrization combines a binned redshift dependence and a smooth evolution in scale avoiding a jump in the matter power spectrum. The formalism developed to test the consistency of current and future data with general relativity is implemented in a package that we make publicly available and call ISiTGR (Integrated Software in Testing General Relativity), an integrated set of modified modules for the publicly available packages CosmoMC and CAMB, including a modified version of the integrated Sachs-Wolfe-galaxy cross correlation module of Ho et al. and a new weak-lensing likelihood module for the refined Hubble Space Telescope Cosmic Evolution Survey weak gravitational lensing tomography data. We obtain parameter constraints and correlation coefficients finding that modified gravity parameters are significantly correlated with σ 8 and mildly correlated with Ω m , for all evolution methods. The degeneracies between σ 8 and modified gravity parameters are found to be substantial for the functional form and also for some specific bins in the hybrid and binned methods indicating that these degeneracies will need to be taken into consideration when using future high precision data.

  19. Hall Thruster Thermal Modeling and Test Data Correlation

    Science.gov (United States)

    Myers, James; Kamhawi, Hani; Yim, John; Clayman, Lauren

    2016-01-01

    The life of Hall Effect thrusters are primarily limited by plasma erosion and thermal related failures. NASA Glenn Research Center (GRC) in cooperation with the Jet Propulsion Laboratory (JPL) have recently completed development of a Hall thruster with specific emphasis to mitigate these limitations. Extending the operational life of Hall thursters makes them more suitable for some of NASA's longer duration interplanetary missions. This paper documents the thermal model development, refinement and correlation of results with thruster test data. Correlation was achieved by minimizing uncertainties in model input and recognizing the relevant parameters for effective model tuning. Throughout the thruster design phase the model was used to evaluate design options and systematically reduce component temperatures. Hall thrusters are inherently complex assemblies of high temperature components relying on internal conduction and external radiation for heat dispersion and rejection. System solutions are necessary in most cases to fully assess the benefits and/or consequences of any potential design change. Thermal model correlation is critical since thruster operational parameters can push some components/materials beyond their temperature limits. This thruster incorporates a state-of-the-art magnetic shielding system to reduce plasma erosion and to a lesser extend power/heat deposition. Additionally a comprehensive thermal design strategy was employed to reduce temperatures of critical thruster components (primarily the magnet coils and the discharge channel). Long term wear testing is currently underway to assess the effectiveness of these systems and consequently thruster longevity.

  20. Correlation and agreement: overview and clarification of competing concepts and measures.

    Science.gov (United States)

    Liu, Jinyuan; Tang, Wan; Chen, Guanqin; Lu, Yin; Feng, Changyong; Tu, Xin M

    2016-04-25

    Agreement and correlation are widely-used concepts that assess the association between variables. Although similar and related, they represent completely different notions of association. Assessing agreement between variables assumes that the variables measure the same construct, while correlation of variables can be assessed for variables that measure completely different constructs. This conceptual difference requires the use of different statistical methods, and when assessing agreement or correlation, the statistical method may vary depending on the distribution of the data and the interest of the investigator. For example, the Pearson correlation, a popular measure of correlation between continuous variables, is only informative when applied to variables that have linear relationships; it may be non-informative or even misleading when applied to variables that are not linearly related. Likewise, the intraclass correlation, a popular measure of agreement between continuous variables, may not provide sufficient information for investigators if the nature of poor agreement is of interest. This report reviews the concepts of agreement and correlation and discusses differences in the application of several commonly used measures.

  1. The quadratic relationship between difficulty of intelligence test items and their correlations with working memory

    Directory of Open Access Journals (Sweden)

    Tomasz eSmoleń

    2015-08-01

    Full Text Available Fluid intelligence (Gf is a crucial cognitive ability that involves abstract reasoning in order to solve novel problems. Recent research demonstrated that Gf strongly depends on the individual effectiveness of working memory (WM. We investigated a popular claim that if the storage capacity underlay the WM-Gf correlation, then such a correlation should increase with an increasing number of items or rules (load in a Gf test. As often no such link is observed, on that basis the storage-capacity account is rejected, and alternative accounts of Gf (e.g., related to executive control or processing speed are proposed. Using both analytical inference and numerical simulations, we demonstrated that the load-dependent change in correlation is primarily a function of the amount of floor/ceiling effect for particular items. Thus, the item-wise WM correlation of a Gf test depends on its overall difficulty, and the difficulty distribution across its items. When the early test items yield huge ceiling, but the late items do not approach floor, that correlation will increase throughout the test. If the early items locate themselves between ceiling and floor, but the late items approach floor, the respective correlation will decrease. For a hallmark Gf test, the Raven test, whose items span from ceiling to floor, the quadratic relationship is expected, and it was shown empirically using a large sample and two types of WMC tasks. In consequence, no changes in correlation due to varying WM/Gf load, or lack of them, can yield an argument for or against any theory of WM/Gf. Moreover, as the mathematical properties of the correlation formula make it relatively immune to ceiling/floor effects for overall moderate correlations, only minor changes (if any in the WM-Gf correlation should be expected for many psychological tests.

  2. The quadratic relationship between difficulty of intelligence test items and their correlations with working memory.

    Science.gov (United States)

    Smolen, Tomasz; Chuderski, Adam

    2015-01-01

    Fluid intelligence (Gf) is a crucial cognitive ability that involves abstract reasoning in order to solve novel problems. Recent research demonstrated that Gf strongly depends on the individual effectiveness of working memory (WM). We investigated a popular claim that if the storage capacity underlay the WM-Gf correlation, then such a correlation should increase with an increasing number of items or rules (load) in a Gf-test. As often no such link is observed, on that basis the storage-capacity account is rejected, and alternative accounts of Gf (e.g., related to executive control or processing speed) are proposed. Using both analytical inference and numerical simulations, we demonstrated that the load-dependent change in correlation is primarily a function of the amount of floor/ceiling effect for particular items. Thus, the item-wise WM correlation of a Gf-test depends on its overall difficulty, and the difficulty distribution across its items. When the early test items yield huge ceiling, but the late items do not approach floor, that correlation will increase throughout the test. If the early items locate themselves between ceiling and floor, but the late items approach floor, the respective correlation will decrease. For a hallmark Gf-test, the Raven-test, whose items span from ceiling to floor, the quadratic relationship is expected, and it was shown empirically using a large sample and two types of WMC tasks. In consequence, no changes in correlation due to varying WM/Gf load, or lack of them, can yield an argument for or against any theory of WM/Gf. Moreover, as the mathematical properties of the correlation formula make it relatively immune to ceiling/floor effects for overall moderate correlations, only minor changes (if any) in the WM-Gf correlation should be expected for many psychological tests.

  3. Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome.

    Science.gov (United States)

    Heintze, Siegward D

    2007-01-01

    An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both

  4. Numerical thermal mathematical model correlation to thermal balance test using adaptive particle swarm optimization (APSO)

    International Nuclear Information System (INIS)

    Beck, T.; Bieler, A.; Thomas, N.

    2012-01-01

    We present structural and thermal model (STM) tests of the BepiColombo laser altimeter (BELA) receiver baffle with emphasis on the correlation of the data with a thermal mathematical model. The test unit is a part of the thermal and optical protection of the BELA instrument being tested under infrared and solar irradiation at University of Bern. An iterative optimization method known as particle swarm optimization has been adapted to adjust the model parameters, mainly the linear conductivity, in such a way that model and test results match. The thermal model reproduces the thermal tests to an accuracy of 4.2 °C ± 3.2 °C in a temperature range of 200 °C after using only 600 iteration steps of the correlation algorithm. The use of this method brings major benefits to the accuracy of the results as well as to the computational time required for the correlation. - Highlights: ► We present model correlations of the BELA receiver baffle to thermal balance tests. ► Adaptive particle swarm optimization has been adapted for the correlation. ► The method improves the accuracy of the correlation and the computational time.

  5. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    Science.gov (United States)

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICCbalance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. CORRELATION OF ULTRASOUND (USG FINDINGS WITH SEROLOGICAL TESTS IN DENGUE FEVER

    Directory of Open Access Journals (Sweden)

    Dayanand

    2016-02-01

    Full Text Available INTRODUCTION Dengue is an endemic and epidemic disease of the tropical and subtropical regions. Between September & October 2012, there was an established outbreak of dengue in Hoskote, near Bangalore. Dengue results in serositis, which can be imaged by ultrasonography. OBJECTIVE To correlate the USG findings with the serological tests in paediatric and adult patients. MATERIALS AND METHODS 110 patients with clinical suspicion of dengue fever during the above period underwent serological tests-NS1, IgM and IgG and were evaluated with USG of the abdomen and thorax. The USG findings were correlated with serological tests. RESULTS 67 Patients were seropositive, 43 were seronegative. The USG findings in seropositive paediatric patients (n=32 and adult patients (n=35 respectively were gall bladder (GB wall edema-27 & 31, hepatomegaly-12 &14, ascites-16 & 12, splenomegaly- 15 & 9, right pleural effusion-14 & 13, left and bilateral pleural effusion-7 & 5. CONCLUSION In our study GB wall edema significantly correlated with seropositivity (p value=0.032. Thus ultrasound is an efficient screening tool in a case of dengue outbreak.

  7. A Chinese version of the Language Screening Test (CLAST for early-stage stroke patients.

    Directory of Open Access Journals (Sweden)

    Hongyan Yang

    Full Text Available There is a severe lack of aphasia screening tools for bedside use in Chinese. A number of aphasia assessment tools have recently been developed abroad, but some of these scales were not suitable for patients with acute stroke. The Language Screening Test (which includes two parallel versions [a/b] in French has been proven to be an effective and time-saving aphasia screening scale for early-stage stroke patients. Therefore, we worked out a Chinese version of the LAST taking into consideration Chinese language and culture. Two preliminary parallel versions (a/b were tested on 154 patients with stroke at acute phase and 107 patients with stroke at non-acute phase, with the Western Aphasia Battery serving as a gold standard. The equivalence between the two parallel versions and the reliability/validity of each version were assessed. The median time to complete one preliminary Chinese version (each had some item redundancy was 98 seconds. Two final parallel versions were established after adjustment/elimination of the redundant items and were found to be equivalent (intra-class correlation coefficient: 0.991. Internal consistency is(Cronbach α for each version [a/b] was 0.956 and 0.965, respectively good. Internal validity was fine: (a no floor or ceiling effect/item redundancy; (b construct validity revealed a 1-dimension structure, just like the French version. The higher educated subjects scored higher than their lower educated counterparts (p<0.01. The external validity: at the optimum cut-off point where the score of version a/b <14 in higher educated group(<13 in lower: the specificity of each version was 0.878/0.902(1/1 in lower and sensitivity was 0.972/0.944(0.944/0.944 in lower. Inter-rater equivalence (intra-class correlation coefficient was 1. The Chinese version of the Language Screening Test was proved to be an efficient and time-saving bedside aphasia screening tool for stroke patients at acute phase and can be used by an average

  8. Reliability, Validity, and Sensitivity of a Novel Smartphone-Based Eccentric Hamstring Strength Test in Professional Football Players.

    Science.gov (United States)

    Lee, Justin W Y; Cai, Ming-Jing; Yung, Patrick S H; Chan, Kai-Ming

    2018-05-01

    To evaluate the test-retest reliability, sensitivity, and concurrent validity of a smartphone-based method for assessing eccentric hamstring strength among male professional football players. A total of 25 healthy male professional football players performed the Chinese University of Hong Kong (CUHK) Nordic break-point test, hamstring fatigue protocol, and isokinetic hamstring strength test. The CUHK Nordic break-point test is based on a Nordic hamstring exercise. The Nordic break-point angle was defined as the maximum point where the participant could no longer support the weight of his body against gravity. The criterion for the sensitivity test was the presprinting and postsprinting difference of the Nordic break-point angle with a hamstring fatigue protocol. The hamstring fatigue protocol consists of 12 repetitions of the 30-m sprint with 30-s recoveries between sprints. Hamstring peak torque of the isokinetic hamstring strength test was used as the criterion for validity. A high test-retest reliability (intraclass correlation coefficient = .94; 95% confidence interval, .82-.98) was found in the Nordic break-point angle measurements. The Nordic break-point angle significantly correlated with isokinetic hamstring peak torques at eccentric action of 30°/s (r = .88, r 2  = .77, P hamstring strength measures among male professional football players.

  9. Estimation of rank correlation for clustered data.

    Science.gov (United States)

    Rosner, Bernard; Glynn, Robert J

    2017-06-30

    It is well known that the sample correlation coefficient (R xy ) is the maximum likelihood estimator of the Pearson correlation (ρ xy ) for independent and identically distributed (i.i.d.) bivariate normal data. However, this is not true for ophthalmologic data where X (e.g., visual acuity) and Y (e.g., visual field) are available for each eye and there is positive intraclass correlation for both X and Y in fellow eyes. In this paper, we provide a regression-based approach for obtaining the maximum likelihood estimator of ρ xy for clustered data, which can be implemented using standard mixed effects model software. This method is also extended to allow for estimation of partial correlation by controlling both X and Y for a vector U_ of other covariates. In addition, these methods can be extended to allow for estimation of rank correlation for clustered data by (i) converting ranks of both X and Y to the probit scale, (ii) estimating the Pearson correlation between probit scores for X and Y, and (iii) using the relationship between Pearson and rank correlation for bivariate normally distributed data. The validity of the methods in finite-sized samples is supported by simulation studies. Finally, two examples from ophthalmology and analgesic abuse are used to illustrate the methods. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  10. On the possibility of extending the tests of quantum mechanical correlations

    International Nuclear Information System (INIS)

    Bergia, S.

    1984-01-01

    Experimental tests of quantum mechanical correlations in connection with Bell's inequality have generally considered decays in sub-systems characterized by two-valued observables. The author analyses the possibility of extending these tests to a much wider class of cases. (Auth.)

  11. Reliability characteristics and applicability of a repeated sprint ability test in male young soccer players

    DEFF Research Database (Denmark)

    Castagna, Carlo; Francini, Lorenzo; Krustrup, Peter

    2018-01-01

    The aim of this study was to examine the usefulness and reliability characteristics of a repeated sprint ability test considering 5 line sprints of 30-m interspersed with 30-s of active recovery in non-elite outfield young male soccer players. Twenty-six (age 14.9±1.2 years, height 1.72±0.12 cm......, body mass 62.2±5.1 kg) players were tested 48 hours and 7 days apart for 5x30-m performance over 5 trials (T1-T5). Short- (T1-T2) and long-term reliability (T1-T3-T4-T5) were assessed with Intraclass Correlation Coefficient (ICC) and with typical error for measurement (TEM). Short- and long...... study revealed that the 5x30-m sprint test is a reliable field test in the short and long-term when the sum of sprint times and the best sprint performance are considered as outcome variables. Sprint performance decrements variables showed large variability across trials....

  12. Clinimetric quality of the fire fighting simulation test as part of the Dutch fire fighters Workers' Health Surveillance

    Directory of Open Access Journals (Sweden)

    Sluiter Judith K

    2010-02-01

    Full Text Available Abstract Background Clinimetric data for the fire fighting simulation test (FFST, a new test proposed for the Workers' Health Surveillance (WHS of Dutch fire fighters, were evaluated. Methods Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC, and standard error of measurement (SEM, were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability. Results The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 ≤ r ≤ -0.33; p Conclusions The FFST was reliable with acceptable agreement after three weeks. Construct validity was moderate. We recommend using FFST as a part of the WHS for Dutch fire fighters. It is advised that fire fighters should perform the FFST once as a trial before judging their performance in testing time during the second performance.

  13. Assessment of a Newly Developed, Active Pneumatic-Driven, Sensorimotor Test and Training Device

    Directory of Open Access Journals (Sweden)

    Wolfram Haslinger

    2014-12-01

    Full Text Available The sensorimotor system (SMS plays an important role in sports and in every day movement. Several tools for assessment and training have been designed. Many of them are directed to specific populations, and have major shortcomings due to the training effect or safety. The aim of the present study was to design and assess a dynamic sensorimotor test and training device that can be adjusted for all levels of performance. The novel pneumatic-driven mechatronic device can guide the trainee, allow independent movements or disrupt the individual with unpredicted perturbations while standing on a platform. The test-reliability was evaluated using intraclass correlation coefficient (ICC. Subjects were required to balance their center of pressure (COP in a target circle (TITC. The time in TITC and the COP error (COPe were recorded for analysis. The results of 22 males and 14 females (23.7 ± 2.6 years showed good to excellent test–retest reliability. The newly designed Active Balance System (ABS was then compared with the Biodex Balance System SD® (BBS. The results of 15 females, 14 males (23.4 ± 1.6 years showed modest correlation in static and acceptable correlation in dynamic conditions, suggesting that ABS could be a reliable and comparable tool for dynamic balance assessments.

  14. Comparison of Sleep Latency and Number of SOREMPs in the Home and Hospital With a Modified Multiple Sleep Latency Test: A Randomized Crossover Study.

    Science.gov (United States)

    Beiske, Kornelia K; Sand, Trond; Rugland, Eyvind; Stavem, Knut

    2017-05-01

    Comparison of mean sleep latencies and number of sleep-onset rapid eye movement periods (SOREMPs) between modified multiple sleep latency test (MSLT) performed in the unattended home and in-hospital laboratory setting. A randomized crossover single-blinded design. Thirty-four subjects referred to MSLT for suspected hypersomnia or narcolepsy were included. Participants were randomized to perform modified MSLT in the unattended home or in the hospital first. Scores in the two settings were compared using Wilcoxon signed-rank test or exact McNemar test. Agreement between home and hospital categorized mean sleep latency and number of SOREMPs was assessed using simple kappa (κ) and proportion agreement. Agreement between home and hospital mean sleep latency was assessed using a Bland-Altman plot and an intraclass correlation coefficient. There was no difference between home and hospital assessment of mean sleep latency (P = 0.86). Two or more SOREMPs were found more frequently on modified MSLTs performed at home compared with those at the hospital (7 and 2, respectively; P = 0.025). Agreement was moderate for categorized sleep latency (κ = 0.53) and fair for categorized SOREMPs (κ = 0.39) in the 2 settings. Analysis of mean sleep latency using intraclass correlation coefficient showed a very good agreement between the two settings. Group mean sleep latency for home modified MSLTs seems to be reliable compared with that for the attended sleep-laboratory setting. Higher rate of SOREMP in the unattended home suggests that napping in a familiar environment facilitates the transition into REM sleep. Further studies are needed to assess the normal limit, sensitivity, and specificity for SOREMP at home before the clinical utility of home-based napping can be determined.

  15. Test-retest reliability of jump execution variables using mechanography: a comparison of jump protocols.

    Science.gov (United States)

    Fitzgerald, John S; Johnson, LuAnn; Tomkinson, Grant; Stein, Jesse; Roemmich, James N

    2018-05-01

    Mechanography during the vertical jump may enhance screening and determining mechanistic causes underlying physical performance changes. Utility of jump mechanography for evaluation is limited by scant test-retest reliability data on force-time variables. This study examined the test-retest reliability of eight jump execution variables assessed from mechanography. Thirty-two women (mean±SD: age 20.8 ± 1.3 yr) and 16 men (age 22.1 ± 1.9 yr) attended a familiarization session and two testing sessions, all one week apart. Participants performed two variations of the squat jump with squat depth self-selected and controlled using a goniometer to 80º knee flexion. Test-retest reliability was quantified as the systematic error (using effect size between jumps), random error (using coefficients of variation), and test-retest correlations (using intra-class correlation coefficients). Overall, jump execution variables demonstrated acceptable reliability, evidenced by small systematic errors (mean±95%CI: 0.2 ± 0.07), moderate random errors (mean±95%CI: 17.8 ± 3.7%), and very strong test-retest correlations (range: 0.73-0.97). Differences in random errors between controlled and self-selected protocols were negligible (mean±95%CI: 1.3 ± 2.3%). Jump execution variables demonstrated acceptable reliability, with no meaningful differences between the controlled and self-selected jump protocols. To simplify testing, a self-selected jump protocol can be used to assess force-time variables with negligible impact on measurement error.

  16. Exploiting Attribute Correlations: A Novel Trace Lasso-Based Weakly Supervised Dictionary Learning Method.

    Science.gov (United States)

    Wu, Lin; Wang, Yang; Pan, Shirui

    2017-12-01

    It is now well established that sparse representation models are working effectively for many visual recognition tasks, and have pushed forward the success of dictionary learning therein. Recent studies over dictionary learning focus on learning discriminative atoms instead of purely reconstructive ones. However, the existence of intraclass diversities (i.e., data objects within the same category but exhibit large visual dissimilarities), and interclass similarities (i.e., data objects from distinct classes but share much visual similarities), makes it challenging to learn effective recognition models. To this end, a large number of labeled data objects are required to learn models which can effectively characterize these subtle differences. However, labeled data objects are always limited to access, committing it difficult to learn a monolithic dictionary that can be discriminative enough. To address the above limitations, in this paper, we propose a weakly-supervised dictionary learning method to automatically learn a discriminative dictionary by fully exploiting visual attribute correlations rather than label priors. In particular, the intrinsic attribute correlations are deployed as a critical cue to guide the process of object categorization, and then a set of subdictionaries are jointly learned with respect to each category. The resulting dictionary is highly discriminative and leads to intraclass diversity aware sparse representations. Extensive experiments on image classification and object recognition are conducted to show the effectiveness of our approach.

  17. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Reliability and convergent validity of the five-step test in people with chronic stroke.

    Science.gov (United States)

    Ng, Shamay S M; Tse, Mimi M Y; Tam, Eric W C; Lai, Cynthia Y Y

    2018-01-10

    (i) To estimate the intra-rater, inter-rater and test-retest reliabilities of the Five-Step Test (FST), as well as the minimum detectable change in FST completion times in people with stroke. (ii) To estimate the convergent validity of the FST with other measures of stroke-specific impairments. (iii) To identify the best cut-off times for distinguishing FST performance in people with stroke from that of healthy older adults. A cross-sectional study. University-based rehabilitation centre. Forty-eight people with stroke and 39 healthy controls. None. The FST, along with (for the stroke survivors only) scores on the Fugl-Meyer Lower Extremity Assessment (FMA-LE), the Berg Balance Scale (BBS), Limits of Stability (LOS) tests, and Activities-specific Balance Confidence (ABC) scale were tested. The FST showed excellent intra-rater (intra-class correlation coefficient; ICC = 0.866-0.905), inter-rater (ICC = 0.998), and test-retest (ICC = 0.838-0.842) reliabilities. A minimum detectable change of 9.16 s was found for the FST in people with stroke. The FST correlated significantly with the FMA-LE, BBS, and LOS results in the forward and sideways directions (r = -0.411 to -0.716, p people with stroke and healthy older adults. The FST is a reliable, easy-to-administer clinical test for assessing stroke survivors' ability to negotiate steps and stairs.

  19. Digital Image Correlation Techniques Applied to Large Scale Rocket Engine Testing

    Science.gov (United States)

    Gradl, Paul R.

    2016-01-01

    Rocket engine hot-fire ground testing is necessary to understand component performance, reliability and engine system interactions during development. The J-2X upper stage engine completed a series of developmental hot-fire tests that derived performance of the engine and components, validated analytical models and provided the necessary data to identify where design changes, process improvements and technology development were needed. The J-2X development engines were heavily instrumented to provide the data necessary to support these activities which enabled the team to investigate any anomalies experienced during the test program. This paper describes the development of an optical digital image correlation technique to augment the data provided by traditional strain gauges which are prone to debonding at elevated temperatures and limited to localized measurements. The feasibility of this optical measurement system was demonstrated during full scale hot-fire testing of J-2X, during which a digital image correlation system, incorporating a pair of high speed cameras to measure three-dimensional, real-time displacements and strains was installed and operated under the extreme environments present on the test stand. The camera and facility setup, pre-test calibrations, data collection, hot-fire test data collection and post-test analysis and results are presented in this paper.

  20. [Evaluation (assessment) of three tests for diagnosis of geohelmints in Colombia].

    Science.gov (United States)

    López, Myriam Consuelo; Moncada, Ligia Inés; Ariza-Araújo, Yoseth; Fernández-Niño, Julián Alfredo; Reyes, Patricia; Nicholls, Rubén Santiago

    2013-01-01

    Soil-transmitted helminth infections are considered a public health problem in developing countries. The diagnostic tests, both for individual parient diagnosis as for population studies should be evaluated in terms of validity and reliability. To compare the direct examination, the modified Ritchie-Frick method, a Kato-Katz designed by a Brazilian group and one designed by the WHO, for the diagnosis of soil-transmitted helminthes. A diagnostic test reliability study was performed. The same stool sample was analyzed by the same observer using four diagnostic tests. 204 samples were obtained, 194 of those fulfilled the inclusion criteria and were analyzed. The observers did not know the participants' identity neither the other tests results. For the analysis the Kato-Katz (WHO) was considered as the gold standard. For the reliability assessment percent agreement, positive percent agreement, Kappa statistic, and intraclass correlation were performed. The Brazilian Kato-Katz showed a good performance with high sensitivity and specificity for T. trichiura and Hookworm with values of 0.97 and 0.96 respectively, and a high specificity with mild sensitivity for A. lumbricoides (0.95 and 0.79) meanwhile the direct examination and the Ritche-Frick method showed a performance between mild and poor. The differences were higher for hookworm and Trichiuris trichiura than for Ascaris lumbricoides. The Brazilian Kato Katz test could be implemented, but further studies are needed to correlate its operative capacity with its feasibility, availability and cost.

  1. A Test-Retest Reliability Study of the Whiplash Disability Questionnaire in Patients With Acute Whiplash-Associated Disorders.

    Science.gov (United States)

    Stupar, Maja; Côté, Pierre; Beaton, Dorcas E; Boyle, Eleanor; Cassidy, J David

    2015-01-01

    The purpose of this study was to determine the test-retest reliability and the Minimal Detectable Change (MDC) of the Whiplash Disability Questionnaire (WDQ) in individuals with acute whiplash-associated disorders (WADs). We performed a test-retest reliability study. We included insurance claimants from Ontario who were at least 18 years of age, within 21 days of their motor vehicle collision and diagnosed as having acute WAD grades I to III. The WDQ, a 13-item questionnaire scored from 0 (no disability) to 130 (complete disability), was administered to all participants at baseline and by telephone 3 days later. We computed the intraclass correlation coefficient (model 2,1) and the MDC with 95% confidence intervals (CIs; MDC95). The mean (SD) age of the 66 participants was 41.6 (12.7) years and 71.2% were female. Twenty-nine percent had WAD I and 71.2% had WAD II. Time since injury ranged from 0 to 19 days. The mean (SD) baseline WDQ score was 49.3 (28.8) and 46.5 (29.8) 3 days later. The intraclass correlation coefficient for the WDQ total score was 0.89 (95% CI, 0.85-0.92) in the entire sample and 0.83 (95% CI, 0.69-0.93) for the 15 participants reporting no change in neck pain. The MDC95 of the WDQ was 21.4 (SD = 14.9) for participants reporting no change. The WDQ was reliable in individuals with acute WAD. There is 95% confidence that a change of approximately one-sixth of the total score is beyond the daily variation of a stable condition. This level of measurement error must be taken into consideration when interpreting change in WDQ scores. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  2. Comparison of heat-testing methodology.

    Science.gov (United States)

    Bierma, Mark M; McClanahan, Scott; Baisden, Michael K; Bowles, Walter R

    2012-08-01

    Patients with irreversible pulpitis occasionally present with a chief complaint of sensitivity to heat. To appropriately diagnose the offending tooth, a variety of techniques have been developed to reproduce this chief complaint. Such techniques cause temperature increases that are potentially damaging to the pulp. Newer electronic instruments control the temperature of a heat-testing tip that is placed directly against a tooth. The aim of this study was to determine which method produced the most consistent and safe temperature increase within the pulp. This consistency facilitates the clinician's ability to differentiate between a normal pulp and irreversible pulpitis. Four operators applied the following methods to each of 4 extracted maxillary premolars (for a total of 16 trials per method): heated gutta-percha, heated ball burnisher, hot water, and a System B unit or Elements unit with a heat-testing tip. Each test was performed for 60 seconds, and the temperatures were recorded via a thermocouple in the pulp chamber. Analysis of the data was performed by using the intraclass correlation coefficient. The least consistent warming was found with hot water. The heat-testing tip also demonstrated greater consistency between operators compared with the other methods. Hot water and the heated ball burnisher caused temperature increases high enough to damage pulp tissue. The Elements unit with a heat-testing tip provides the most consistent warming of the dental pulp. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Reliability of Strength Testing using the Advanced Resistive Exercise Device and Free Weights

    Science.gov (United States)

    English, Kirk L.; Loehr, James A.; Laughlin, Mitzi A.; Lee, Stuart M. C.; Hagan, R. Donald

    2008-01-01

    The Advanced Resistive Exercise Device (ARED) was developed for use on the International Space Station as a countermeasure against muscle atrophy and decreased strength. This investigation examined the reliability of one-repetition maximum (1RM) strength testing using ARED and traditional free weight (FW) exercise. Methods: Six males (180.8 +/- 4.3 cm, 83.6 +/- 6.4 kg, 36 +/- 8 y, mean +/- SD) who had not engaged in resistive exercise for at least six months volunteered to participate in this project. Subjects completed four 1RM testing sessions each for FW and ARED (eight total sessions) using a balanced, randomized, crossover design. All testing using one device was completed before progressing to the other. During each session, 1RM was measured for the squat, heel raise, and deadlift exercises. Generalizability (G) and intraclass correlation coefficients (ICC) were calculated for each exercise on each device and were used to predict the number of sessions needed to obtain a reliable 1RM measurement (G . 0.90). Interclass reliability coefficients and Pearson's correlation coefficients (R) also were calculated for the highest 1RM value (1RM9sub peak)) obtained for each exercise on each device to quantify 1RM relationships between devices.

  4. Development and psychometric testing of a trans-professional evidence-based practice profile questionnaire.

    Science.gov (United States)

    McEvoy, Maureen Patricia; Williams, Marie T; Olds, Timothy Stephen

    2010-01-01

    Previous survey tools operationalising knowledge, attitudes or beliefs about evidence-based practice (EBP) have shortcomings in content, psychometric properties and target audience. This study developed and psychometrically assessed a self-report trans-professional questionnaire to describe an EBP profile. Sixty-six items were collated from existing EBP questionnaires and administered to 526 academics and students from health and non-health backgrounds. Principal component factor analysis revealed the presence of five factors (Relevance, Terminology, Confidence, Practice and Sympathy). Following expert panel review and pilot testing, the 58-item final questionnaire was disseminated to 105 subjects on two occasions. Test-retest and internal reliability were quantified using intra-class correlation coefficients (ICCs) and Cronbach's alpha, convergent validity against a commonly used EBP questionnaire by Pearson's correlation coefficient and discriminative validity via analysis of variance (ANOVA) based on exposure to EBP training. The final questionnaire demonstrated acceptable internal consistency (Cronbach's alpha 0.96), test-retest reliability (ICCs range 0.77-0.94) and convergent validity (Practice 0.66, Confidence 0.80 and Sympathy 0.54). Three factors (Relevance, Terminology and Confidence) distinguished EBP exposure groups (ANOVA p profile (EBP(2)) questionnaire is a reliable instrument with the ability to discriminate for three factors, between respondents with differing EBP exposures.

  5. Control and test software for IRAM WideX correlator

    International Nuclear Information System (INIS)

    Blanchet, S.; Broguiere, D.; Chavatte, P.; Morel, F.; Perrigouard, A.; Torres, M.

    2012-01-01

    IRAM is an international research institute for radio astronomy. It has designed a new correlator called WideX for the Plateau de Bure interferometer (an array of six 15-meter telescopes) in the French Alps. The device started its official service in February 2010. This correlator must be driven in real-time at 32 Hz for sending parameters and for data acquisition. With 3.67 million channels, distributed over 1792 dedicated chips, that produce a 1.87 Gbits/sec data output rate, the data acquisition and processing and also the automatic hardware-failure detection are big challenges for the software. This article presents the software that has been developed to drive and test the correlator. In particular it presents an innovative usage of a high speed optical link, initially developed for the CERN ALICE experiment, associated with real-time Linux (RTAI) to achieve our goals. (authors)

  6. A critical assessment of the equal environment assumption of the twin method for schizophrenia

    Directory of Open Access Journals (Sweden)

    Roar eFosse

    2015-04-01

    Full Text Available The classical twin method (CTM is central to the view that schizophrenia is ~80% heritable. The CTM rests on the equal environments assumption (EEA that identical and fraternal twin pairs experience equivalent trait relevant environmental exposures. The EEA has not been directly tested for schizophrenia with measures of child social adversity, which is particularly etiologically relevant to the disorder. However, if child social adversity is more similar in identical than fraternal pairs in the general twin population, the EEA is unlikely to be valid for schizophrenia, a question which we tested in this study. Using results from prior twin studies, we tested if intraclass correlations for the following five categories of child social adversity are larger in identical than fraternal twins: bullying, sexual abuse, physical maltreatment, emotional neglect and abuse, and general trauma. Eleven relevant studies that encompassed 9119 twin pairs provided 24 comparisons of intraclass correlations, which we grouped into the five social exposure categories. Fisher’s z-test revealed significantly higher correlations in identical than fraternal pairs for each exposure category (z ≥ 3.53, p <.001. The difference remained consistent across gender, study site (country, sample size, whether psychometric instruments were used, whether interviewing was proximate or distant to the exposures, and whether informants were twins or third persons. Combined with other evidence that the differential intraclass correlation for child social adversity cannot be explained by evocative gene-environment covariation, our results indicate that the CTM does not provide any valid indication of genomic effects in schizophrenia.

  7. Correlates of STI testing among vocational school students in the Netherlands

    Directory of Open Access Journals (Sweden)

    Mackenbach Johan P

    2010-11-01

    Full Text Available Abstract Background Adolescents are at risk for acquiring sexually transmitted infections (STIs. However, test rates among adolescents in the Netherlands are low and effective interventions that encourage STI testing are scarce. Adolescents who attend vocational schools are particularly at risk for STI. The purpose of this study is to inform the development of motivational health promotion messages by identifying the psychosocial correlates of STI testing intention among adolescents with sexual experience attending vocational schools. Methods This study was conducted among 501 students attending vocational schools aged 16 to 25 years (mean 18.3 years ± 2.1. Data were collected via a web-based survey exploring relationships, sexual behavior and STI testing behavior. Items measuring the psychosocial correlates of testing were derived from Fishbein's Integrative Model. Data were subjected to multiple regression analyses. Results Students reported substantial sexual risk behavior and low intention to participate in STI testing. The model explained 39% of intention to engage in STI testing. The most important predictor was attitude. Perceived norms, perceived susceptibility and test site characteristics were also significant predictors. Conclusions The present study provides important and relevant empirical input for the development of health promotion interventions aimed at motivating adolescents at vocational schools in the Netherlands to participate in STI testing. Health promotion interventions developed for this group should aim to change attitudes, address social norms and increase personal risk perception for STI while also promoting the accessibility of testing facilities.

  8. RELIABILITY OF THE ONE REPETITION-MAXIMUM POWER CLEAN TEST IN ADOLESCENT ATHLETES

    Science.gov (United States)

    Faigenbaum, Avery D.; McFarland, James E.; Herman, Robert; Naclerio, Fernando; Ratamess, Nicholas A.; Kang, Jie; Myer, Gregory D.

    2013-01-01

    Although the power clean test is routinely used to assess strength and power performance in adult athletes, the reliability of this measure in younger populations has not been examined. Therefore, the purpose of this study was to determine the reliability of the one repetition maximum (1 RM) power clean in adolescent athletes. Thirty-six male athletes (age 15.9 ± 1.1 yrs, body mass 79.1 ± 20.3 kg, height 175.1 ±7.4 cm) who had more than 1 year of training experience with weightlifting exercises performed a 1 RM power clean on two nonconsecutive days in the afternoon following standardized procedures. All test procedures were supervised by a senior level weightlifting coach and consisted of a systematic progression in test load until the maximum resistance that could be lifted for one repetition using proper exercise technique was determined. Data were analyzed using an intraclass correlation coefficient (ICC [2,k]), Pearson correlation coefficient (r), repeated measures ANOVA, Bland-Altman plot, and typical error analyses. Analysis of the data revealed that the test measures were highly reliable demonstrating a test-retest ICC of 0.98 (95% CI = 0.96–0.99). Testing also demonstrated a strong relationship between 1 RM measures on trial 1 and trial 2 (r=0.98, pinjuries occurred during the study period and the testing protocol was well-tolerated by all subjects. These findings indicate that 1 RM power clean testing has a high degree of reproducibility in trained male adolescent athletes when standardized testing procedures are followed and qualified instruction is present. PMID:22233786

  9. Test of gross motor development-2 for Filipino children with intellectual disability: validity and reliability.

    Science.gov (United States)

    Capio, Catherine M; Eguia, Kathlynne F; Simons, Johan

    2016-01-01

    This study aimed to examine aspects of validity and reliability of the Test of Gross Motor Development-2 (TGMD-2) in Filipino children with intellectual disability. Content and construct validity were verified, as well as inter-rater and intra-rater reliability. Two paediatric physiotherapists tested 81 children with intellectual disability (mean age = 9.29 ± 2.71 years) on locomotor and object control skills. Analysis of covariance, confirmatory factor analysis and analysis of variance were used to test validity, while Cronbach's alpha, intra-class correlation coefficients (ICC) and Bland-Altman plots were used to examine reliability. Age was a significant predictor of locomotor and object control scores (P = 0.004). The data fit the hypothesised two-factor model with fit indices as follows: χ(2) = 33.525, DF = 34, P = 0.491, χ(2)/DF = 0.986. As hypothesised, gender was a significant predictor for object control skills (P = 0.038). Participants' mean scores were significantly below mastery (locomotor, P intellectual disability.

  10. The Test-Retest Reliability of New Generation Power Indices of Wingate All-Out Test

    Directory of Open Access Journals (Sweden)

    Ozgur Ozkaya

    2018-04-01

    Full Text Available Although reliability correlations of traditional power indices of the Wingate test have been well documented, no study has analyzed new generation power indices based on milliseconds obtained from a Peak Bike. The purpose of this study was to investigate the retest reliability of new generation power indices. Thirty-two well-trained male athletes who were specialized in basketball, football, tennis, or track and field volunteered to take part in the study (age: 24.3 ± 2.2 years; body mass: 77 ± 8.3 kg; height: 180.3 ± 6.3 cm. Participants performed two Wingate all-out sessions on two separate days. Intra-class correlation coefficient (ICC, standard error measurement (SEM, smallest real differences (SRD and coefficient of variation (CV scores were analyzed based on the test and retest data. Reliability results of traditional power indices calculated based on 5-s means such as peak power, average power, power drop, and fatigue index ratio were similar with the previous findings in literature (ICC ≥ 0.94; CV ≤ 2.8%; SEM ≤ 12.28; SRD% ≤ 7.7%. New generation power indices such as peak power, average power, lowest power, power drop, fatigue index, power decline, maximum speed as rpm, and amount of total energy expenditure demonstrated high reliability (ICC ≥ 0.94; CV ≤ 4.3%; SEM ≤ 10.36; SRD% ≤ 8.8%. Time to peak power, time at maximum speed, and power at maximum speed showed a moderate level of reliability (ICC ≥ 0.73; CV ≤ 8.9%; SEM ≤ 63.01; SRD% ≤ 22.4%. The results of this study indicate that reliability correlations and SRD% of new generation power and fatigue-related indices are similar with traditional 5-s means. However, new time-related indices are very sensitive and moderately reliable.

  11. Lack of Correlation between Severity of Clinical Symptoms, Skin Test Reactivity, and Radioallergosorbent Test Results in Venom-Allergic Patients

    Directory of Open Access Journals (Sweden)

    Warrington RJ

    2006-06-01

    Full Text Available Abstract Purpose To retrospectively examine the relation between skin test reactivity, venom-specific immunoglobulin E (IgE antibody levels, and severity of clinical reaction in patients with insect venom allergy. Method Thirty-six patients (including 15 females who presented with a history of allergic reactions to insect stings were assessed. The mean age at the time of the reactions was 33.4 ± 15.1 years (range, 4-76 years, and patients were evaluated 43.6 ± 90 months (range, 1-300 months after the reactions. Clinical reactions were scored according to severity, from 1 (cutaneous manifestations only to 3 (anaphylaxis with shock. These scores were compared to scores for skin test reactivity (0 to 5, indicating the log increase in sensitivity from 1 μg/mL to 0.0001 μg/mL and radioallergosorbent test (RAST levels (0 to 4, indicating venom-specific IgE levels, from undetectable to >17.5 kilounits of antigen per litre [kUA/L]. Results No correlation was found between skin test reactivity (Spearman's coefficient = 0.15, p = .377 or RAST level (Spearman's coefficient = 0.32, p = .061 and the severity of reaction. Skin test and RAST scores both differed significantly from clinical severity (p p = .042. There was no correlation between skin test reactivity and time since reaction (Spearman's coefficient = 0.18, p = .294 nor between RAST and time since reaction (r = 0.1353, p = .438. Elimination of patients tested more than 12 months after their reaction still produced no correlation between skin test reactivity (p = .681 or RAST score (p = .183 and the severity of the clinical reaction. Conclusion In venom-allergic patients (in contrast to reported findings in cases of inhalant IgE-mediated allergy, there appears to be no significant correlation between the degree of skin test reactivity or levels of venom-specific IgE (determined by RAST and the severity of the clinical reaction.

  12. Novel application of a Wii remote to measure spasticity with the pendulum test: Proof of concept.

    Science.gov (United States)

    Yeh, Chien-Hung; Hung, Chi-Yao; Wang, Yung-Hung; Hsu, Wei-Tai; Chang, Yi-Chung; Yeh, Jia-Rong; Lee, Po-Lei; Hu, Kun; Kang, Jiunn-Horng; Lo, Men-Tzung

    2016-01-01

    The pendulum test is a standard clinical test for quantifying the severity of spasticity. In the test, an electrogoniometer is typically used to measure the knee angular motion. The device is costly and difficult to set up such that the pendulum test is normally time consuming. The goal of this study is to determine whether a Nintendo Wii remote can replace the electrogroniometer for reliable assessment of the angular motion of the knee in the pendulum test. The pendulum test was performed in three control participants and 13 hemiplegic stroke patients using both a Wii remote and an electrogoniometer. The correlation coefficient and the Bland-Altman difference plot were used to compare the results obtained from the two devices. The Wilcoxon signed-rank test was used to compare the difference between hemiplegia-affected and nonaffected sides in the hemiplegic stroke patients. There was a fair to strong correlation between measurements from the Wii remote and the electrogoniometer (0.513intraclass correlation coefficient, standard error of measurement, and minimum detectable differences were highly consistent for both devices. Our findings suggest that the Wii remote may serve as a convenient and cost-efficient tool for the assessment of spasticity. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. On the use of SEM correlative tools for in situ mechanical tests.

    Science.gov (United States)

    Shi, Qiwei; Roux, Stéphane; Latourte, Félix; Hild, François; Loisnard, Dominique; Brynaert, Nicolas

    2018-01-01

    In situ SEM mechanical tests are key to study crystal plasticity. In particular, imaging and diffraction (EBSD) allow microstructure and surface kinematics to be monitored all along the test. However, to get a full benefit from different modalities, it is necessary to register all images and crystallographic orientation maps from EBSD into the same frame. Different correlative approaches tracking either Pt surface markings, crystal orientations or grain boundaries, allow such registrations to be performed and displacement as well as rotation fields to be measured, a primary information for crystal plasticity identification. However, the different contrasts that are captured in different modalities and unavoidable stage motions also give rise to artifacts that are to be corrected to register the different information onto the same material points. The same image correlation tools reveal very powerful to correct such artifacts. Illustrated by an in situ uniaxial tensile test performed on a bainitic-ferritic steel sample, recent advances in image correlation techniques are reviewed and shown to provide a comprehensive picture of local strain and rotation maps. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Development and reliability testing of a food store observation form.

    Science.gov (United States)

    Rimkus, Leah; Powell, Lisa M; Zenk, Shannon N; Han, Euna; Ohri-Vachaspati, Punam; Pugach, Oksana; Barker, Dianne C; Resnick, Elissa A; Quinn, Christopher M; Myllyluoma, Jaana; Chaloupka, Frank J

    2013-01-01

    To develop a reliable food store observational data collection instrument to be used for measuring product availability, pricing, and promotion. Observational data collection. A total of 120 food stores (26 supermarkets, 34 grocery stores, 54 gas/convenience stores, and 6 mass merchandise stores) in the Chicago metropolitan statistical area. Inter-rater reliability for product availability, pricing, and promotion measures on a food store observational data collection instrument. Cohen's kappa coefficient and proportion of overall agreement for dichotomous variables and intra-class correlation coefficient for continuous variables. Inter-rater reliability, as measured by average kappa coefficient, was 0.84 for food and beverage product availability measures, 0.80 for interior store characteristics, and 0.70 for exterior store characteristics. For continuous measures, average intra-class correlation coefficient was 0.82 for product pricing measures; 0.90 for counts of fresh, frozen, and canned fruit and vegetable options; and 0.85 for counts of advertisements on the store exterior and property. The vast majority of measures demonstrated substantial or almost perfect agreement. Although some items may require revision, results suggest that the instrument may be used to reliably measure the food store environment. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  15. The prone bridge test: Performance, validity, and reliability among older and younger adults.

    Science.gov (United States)

    Bohannon, Richard W; Steffl, Michal; Glenney, Susan S; Green, Michelle; Cashwell, Leah; Prajerova, Kveta; Bunn, Jennifer

    2018-04-01

    The prone bridge maneuver, or plank, has been viewed as a potential alternative to curl-ups for assessing trunk muscle performance. The purpose of this study was to assess prone bridge test performance, validity, and reliability among younger and older adults. Sixty younger (20-35 years old) and 60 older (60-79 years old) participants completed this study. Groups were evenly divided by sex. Participants completed surveys regarding physical activity and abdominal exercise participation. Height, weight, body mass index (BMI), and waist circumference were measured. On two occasions, 5-9 days apart, participants held a prone bridge until volitional exhaustion or until repeated technique failure. Validity was examined using data from the first session: convergent validity by calculating correlations between survey responses, anthropometrics, and prone bridge time, known groups validity by using an ANOVA comparing bridge times of younger and older adults and of men and women. Test-retest reliability was examined by using a paired t-test to compare prone bridge times for Session1 and Session 2. Furthermore, an intraclass correlation coefficient (ICC) was used to characterize relative reliability and minimal detectable change (MDC 95% ) was used to describe absolute reliability. The mean prone bridge time was 145.3 ± 71.5 s, and was positively correlated with physical activity participation (p ≤ 0.001) and negatively correlated with BMI and waist circumference (p ≤ 0.003). Younger participants had significantly longer plank times than older participants (p = 0.003). The ICC between testing sessions was 0.915. The prone bridge test is a valid and reliable measure for evaluating abdominal performance in both younger and older adults. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Quantifying interhemispheric symmetry of somatosensory evoked potentials with the intraclass correlation coefficient

    NARCIS (Netherlands)

    van de Wassenberg, Wilma J. G.; van der Hoeven, Johannes H.; Leenders, Klaus L.; Maurits, Natasha M.

    Although large intersubject variability is reported for cortical somatosensory evoked potentials (SEPs), variability between hemispheres within one subject is thought to be small. Therefore, interhemispheric comparison of SEP waveforms might be clinically useful to detect unilateral abnormalities in

  17. Measuring outcomes in allergic rhinitis: psychometric characteristics of a Spanish version of the congestion quantifier seven-item test (CQ7

    Directory of Open Access Journals (Sweden)

    Mullol Joaquim

    2011-03-01

    Full Text Available Abstract Background No control tools for nasal congestion (NC are currently available in Spanish. This study aimed to adapt and validate the Congestion Quantifier Seven Item Test (CQ7 for Spain. Methods CQ7 was adapted from English following international guidelines. The instrument was validated in an observational, prospective study in allergic rhinitis patients with NC (N = 166 and a control group without NC (N = 35. Participants completed the CQ7, MOS sleep questionnaire, and a measure of psychological well-being (PGWBI. Clinical data included NC severity rating, acoustic rhinometry, and total symptom score (TSS. Internal consistency was assessed using Cronbach's alpha and test-retest reliability using the intraclass correlation coefficient (ICC. Construct validity was tested by examining correlations with other outcome measures and ability to discriminate between groups classified by NC severity. Sensitivity and specificity were assessed using Area under the Receiver Operating Curve (AUC and responsiveness over time using effect sizes (ES. Results Cronbach's alpha for the CQ7 was 0.92, and the ICC was 0.81, indicating good reliability. CQ7 correlated most strongly with the TSS (r = 0.60, p Conclusions The Spanish version of the CQ7 is appropriate for detecting, measuring, and monitoring NC in allergic rhinitis patients.

  18. A goodness-of-fit test for occupancy models with correlated within-season revisits

    Science.gov (United States)

    Wright, Wilson; Irvine, Kathryn M.; Rodhouse, Thomas J.

    2016-01-01

    Occupancy modeling is important for exploring species distribution patterns and for conservation monitoring. Within this framework, explicit attention is given to species detection probabilities estimated from replicate surveys to sample units. A central assumption is that replicate surveys are independent Bernoulli trials, but this assumption becomes untenable when ecologists serially deploy remote cameras and acoustic recording devices over days and weeks to survey rare and elusive animals. Proposed solutions involve modifying the detection-level component of the model (e.g., first-order Markov covariate). Evaluating whether a model sufficiently accounts for correlation is imperative, but clear guidance for practitioners is lacking. Currently, an omnibus goodnessof- fit test using a chi-square discrepancy measure on unique detection histories is available for occupancy models (MacKenzie and Bailey, Journal of Agricultural, Biological, and Environmental Statistics, 9, 2004, 300; hereafter, MacKenzie– Bailey test). We propose a join count summary measure adapted from spatial statistics to directly assess correlation after fitting a model. We motivate our work with a dataset of multinight bat call recordings from a pilot study for the North American Bat Monitoring Program. We found in simulations that our join count test was more reliable than the MacKenzie–Bailey test for detecting inadequacy of a model that assumed independence, particularly when serial correlation was low to moderate. A model that included a Markov-structured detection-level covariate produced unbiased occupancy estimates except in the presence of strong serial correlation and a revisit design consisting only of temporal replicates. When applied to two common bat species, our approach illustrates that sophisticated models do not guarantee adequate fit to real data, underscoring the importance of model assessment. Our join count test provides a widely applicable goodness-of-fit test and

  19. Open source posturography.

    Science.gov (United States)

    Rey-Martinez, Jorge; Pérez-Fernández, Nicolás

    2016-12-01

    The proposed validation goal of 0.9 in intra-class correlation coefficient was reached with the results of this study. With the obtained results we consider that the developed software (RombergLab) is a validated balance assessment software. The reliability of this software is dependent of the used force platform technical specifications. Develop and validate a posturography software and share its source code in open source terms. Prospective non-randomized validation study: 20 consecutive adults underwent two balance assessment tests, six condition posturography was performed using a clinical approved software and force platform and the same conditions were measured using the new developed open source software using a low cost force platform. Intra-class correlation index of the sway area obtained from the center of pressure variations in both devices for the six conditions was the main variable used for validation. Excellent concordance between RombergLab and clinical approved force platform was obtained (intra-class correlation coefficient =0.94). A Bland and Altman graphic concordance plot was also obtained. The source code used to develop RombergLab was published in open source terms.

  20. Statistical correlation of structural mode shapes from test measurements and NASTRAN analytical values

    Science.gov (United States)

    Purves, L.; Strang, R. F.; Dube, M. P.; Alea, P.; Ferragut, N.; Hershfeld, D.

    1983-01-01

    The software and procedures of a system of programs used to generate a report of the statistical correlation between NASTRAN modal analysis results and physical tests results from modal surveys are described. Topics discussed include: a mathematical description of statistical correlation, a user's guide for generating a statistical correlation report, a programmer's guide describing the organization and functions of individual programs leading to a statistical correlation report, and a set of examples including complete listings of programs, and input and output data.

  1. Bronchial asthma: correlation of quantitative CT and the pulmonary function test

    International Nuclear Information System (INIS)

    Park, Gun; Jin, Gong Yong; Jeon, Su Bin; Han, Young Min

    2007-01-01

    The purpose of this study was to assess the availability of quantitative computed tomography (QCT) in the evaluation asthma patients and to correlate its use with the pulmonary function test (PFT). Thirty asthmatic patients and thirty normal volunteers were prospectively evaluated by the use of HRCT and the PFT. By using 16 slice MDCT, HRCT was performed from the apex to the base of both lungs at the end inspiration and end expiration periods in all patients and images were reconstructed to a thickness of 1 mm (window level: -750 HU, window width: 1,500 HU). We analyzed each image for the whole lung using the Pulmo CT program. PFTs including FVC and FEV1 were performed one week prior and one week after the completion of a HRCT. The Difference of QCT (the mean lung density and subrange ratio) between volunteers and asthmatic patients was analyzed by using the Student's t-test. Spearman's correlation test was used to determine the association between PFT and QCT. The mean lung density (MLD) and subrange ratio were lower in asthmatic patients than in volunteers for and expiration and no difference was seen between asthmatic patients and volunteers for end inspiration. FVC and FEV1 were lower in asthmatic patients than in volunteers. A decrease in FVC and FEV1 correlated with changes in the MLD and subrange ratio for end expiration. QCT such as MLD and the subrange ratio using HRCT can be used to indirectly assess the pulmonary function of the asthma patient. The PFT seems to correlate better with the MLD and subrange ratio for expiratory QCT of the asthma patient than with inspiratory QCT

  2. Cross-Cultural Adaptation, Validation, and Reliability Testing of the Modified Oswestry Disability Questionnaire in Persian Population with Low Back Pain.

    Science.gov (United States)

    Baradaran, Aslan; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Kachooei, Amir Reza

    2016-04-01

    Prospective study. We aimed to validate the Persian version of the modified Oswestry disability questionnaire (MODQ) in patients with low back pain. Modified Oswestry low back pain disability questionnaire is a well-known condition-specific outcome measure that helps quantify disability in patients with lumbar syndromes. To test the validity in a pilot study, the Persian MODQ was administered to 25 individuals with low back pain. We then enrolled 200 consecutive patients with low back pain to fill the Persian MODQ as well as the short form 36 (SF-36) questionnaire. Convergent validity of the MODQ was tested using the Spearman's correlation coefficient between the MODQ and SF-36 subscales. Intraclass correlation coefficient (ICC) and Cronbach's α coefficient were measured to test the reliability between test and retest and internal consistency of all items, respectively. ICC for individual items ranged from 0.43 to 0.80 showing good reliability and reproducibility of each individual item. Cronbach's α coefficient was 0.69 showing good internal consistency across all 10 items of the Persian MODQ. Total MODQ score showed moderate to strong correlation with the eight subscales and the two domains of the SF-36. The highest correlation was between the MODQ and the physical functioning subscale of the SF-36 (r=-0.54, pPersian version of the MODQ is a valid and reliable tool for the assessment of the disability following low back pain.

  3. Correlation Results for a Mass Loaded Vehicle Panel Test Article Finite Element Models and Modal Survey Tests

    Science.gov (United States)

    Maasha, Rumaasha; Towner, Robert L.

    2012-01-01

    High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons

  4. Viability of gait speed test in hospitalized elderly patients

    Directory of Open Access Journals (Sweden)

    Bruno Prata Martinez

    Full Text Available ABSTRACT Objective: The gait speed test (GST is a physical test that can predict falls and aid in the diagnosis of sarcopenia in the elderly. However, to our knowledge, there have been no studies evaluating its reproducibility in hospitalized elderly patients. The objective of this study was to evaluate the safety and reproducibility of the six-meter GST (6GST in hospitalized elderly patients. Methods: This repeated measures study involved hospitalized elderly patients (≥ 60 years of age who underwent the 6GST by the fifth day of hospitalization, were able to walk without assistance, and presented no signs of dyspnea or pain that would prevent them from performing the test. The 6GST was performed three times in sequence, with a rest period between each test, in a level corridor. Gait speed was measured in meters/second. Reproducibility was assessed by comparing the means, intraclass correlation coefficients (ICCs and Bland-Altman plots. Results: We evaluated 110 elderly patients in a total of 330 tests. All participants completed all of the tests. The comparisons between the speeds obtained during the three tests showed high ICCs and a low mean bias (Bland-Altman plots. The correlation and accuracy were greatest when the mean maximum speed was compared with that obtained in the third test (1.26 ± 0.44 m/s vs. 1.22 ± 0.44 m/s; ICC = 0.99; p = 0.001; mean bias = 0.04; and limits of agreement = −0.27 to 0.15. Conclusions: The 6GST was proven to be safe and to have good reproducibility in this sample of hospitalized elderly patients. The third measurement seems to correspond to the maximum speed, since the first two measurements underestimated the actual performance.

  5. Reproducibility of an aerobic endurance test for nonexpert swimmers.

    Science.gov (United States)

    Veronese da Costa, Adalberto; Costa, Manoel da Cunha; Carlos, Daniel Medeiros; Guerra, Luis Marcos de Medeiros; Silva, Antônio José; Barbosa, Tiago Manoel Cabral Dos Santos

    2012-01-01

    This study aimed to verify the reproduction of an aerobic test to determine nonexpert swimmers' resistance. The sample consisted of 24 male swimmers (age: 22.79 ± 3.90 years; weight: 74.72 ± 11.44 kg; height: 172.58 ± 4.99 cm; and fat percentage: 15.19% ± 3.21%), who swim for 1 hour three times a week. A new instrument was used in this study (a Progressive Swim Test): the swimmer wore an underwater MP3 player and increased their swimming speed on hearing a beep after every 25 meters. Each swimmer's heart rate was recorded before the test (BHR) and again after the test (AHR). The rate of perceived exertion (RPE) and the number of laps performed (NLP) were also recorded. The sample size was estimated using G*Power software (v 3.0.10; Franz Faul, Kiel University, Kiel, Germany). The descriptive values were expressed as mean and standard deviation. After confirming the normality of the data using both the Shapiro-Wilk and Levene tests, a paired t-test was performed to compare the data. The Pearson's linear correlation (r) and intraclass coefficient correlation (ICC) tests were used to determine relative reproducibility. The standard error of measurement (SEM) and the coefficient of variation (CV) were used to determine absolute reproducibility. The limits of agreement and the bias of the absolute and relative values between days were determined by Bland-Altman plots. All values had a significance level of P 0.50 and ICC > 0.66. The SEM had a variation of ±2% and the CV was 0.90; SEM swimmers. The Progressive Swim Test for nonexpert swimmers produces comparable results for noncompetitive swimmers with a favorable degree of reproducibility, thus presenting possible applications for researching the physiological performance of nonexpert swimmers.

  6. Study protocol of psychometric properties of the Spanish translation of a competence test in evidence based practice: the Fresno test.

    Science.gov (United States)

    Argimon-Pallàs, Josep M; Flores-Mateo, Gemma; Jiménez-Villa, Josep; Pujol-Ribera, Enriqueta; Foz, Gonçal; Bundó-Vidiella, Magda; Juncosa, Sebastià; Fuentes-Bellido, Cruz M; Pérez-Rodríguez, Belén; Margalef-Pallarès, Francesc; Villafafila-Ferrero, Rosa; Forès-Garcia, Dolors; Roman-Martínez, Josep; Vilert-Garroga, Esther

    2009-02-24

    There are few high-quality instruments for evaluating the effectiveness of Evidence-Based Practice (EBP) curricula with objective outcomes measures. The Fresno test is an instrument that evaluates most of EBP steps with a high reliability and validity in the English original version. The present study has the aims to translate the Fresno questionnaire into Spanish and its subsequent validation to ensure the equivalence of the Spanish version against the English original. The questionnaire will be translated with the back translation technique and tested in Primary Care Teaching Units in Catalonia (PCTU). Participants will be: (a) tutors of Family Medicine residents (expert group); (b) Family Medicine residents in their second year of the Family Medicine training program (novice group), and (c) Family Medicine physicians (intermediate group). The questionnaire will be administered before and after an educational intervention. The educational intervention will be an interactive four half-day sessions designed to develop the knowledge and skills required to EBP. Responsiveness statistics used in the analysis will be the effect size, the standardised response mean and Guyatt's method. For internal consistency reliability, two measures will be used: corrected item-total correlations and Cronbach's alpha. Inter-rater reliability will be tested using Kappa coefficient for qualitative items and intra-class correlation coefficient for quantitative items and the overall score. Construct validity, item difficulty, item discrimination and feasibility will be determined. The validation of the Fresno questionnaire into different languages will enable the expansion of the questionnaire, as well as allowing comparison between countries and the evaluation of different teaching models.

  7. 4-Meter Gait Speed Test in Chronic Obstructive Pulmonary Disease: INTERRATER RELIABILITY USING A STOPWATCH.

    Science.gov (United States)

    Bisca, Gianna Waldrich; Fava, Lucas Rodrigues; Morita, Andrea Akemi; Machado, Felipe Vilaça Cavallari; Pitta, Fabio; Hernandes, Nidia Aparecida

    2017-12-14

    4-meter gait speed (4MGS) is increasingly used to assess functional performance in patients with chronic obstructive pulmonary disease. However, the current literature lacks information regarding some technical standards for this test. Therefore, the purpose of this study was to compare and to evaluate the interrater reliability between a stopwatch and video recording used as timing systems for the 4MGS in patients with chronic obstructive pulmonary disease, as well as to verify the interrater reliability between 2 observers measuring the 4MGS time using a manual stopwatch. Fifty-one patients performed the 4MGS using 4 different protocols (random order): walking at the usual and maximum speed in a 4-meter course and walking at the same 2 speeds on an 8-m course using a 2-m acceleration zone, a 4-meter timing area, and a 2-m deceleration zone. Gait speed was measured simultaneously using a stopwatch and a video recording. In a subanalysis (n = 24), 2 independent observers timed the 4MGS using a stopwatch. There was no significant difference in comparison between the 2 timing methods (P > .05 for all), and the reliability between video recording and stopwatch was excellent in all 4MGS studied protocols (intraclass correlation coefficient ≥ 0.91). Moreover, when comparing gait speed measured by 2 observers using a stopwatch, no significant difference was found among all proposed protocols (P > .05 for all), and there was also excellent reliability between the 2 independent observers (intraclass correlation coefficient ≥ 0.94). The stopwatch, a low-cost and feasible tool, is reliable as a timing device for the 4MGS in patients with chronic obstructive pulmonary disease.

  8. Testing Group Mean Differences of Latent Variables in Multilevel Data Using Multiple-Group Multilevel CFA and Multilevel MIMIC Modeling.

    Science.gov (United States)

    Kim, Eun Sook; Cao, Chunhua

    2015-01-01

    Considering that group comparisons are common in social science, we examined two latent group mean testing methods when groups of interest were either at the between or within level of multilevel data: multiple-group multilevel confirmatory factor analysis (MG ML CFA) and multilevel multiple-indicators multiple-causes modeling (ML MIMIC). The performance of these methods were investigated through three Monte Carlo studies. In Studies 1 and 2, either factor variances or residual variances were manipulated to be heterogeneous between groups. In Study 3, which focused on within-level multiple-group analysis, six different model specifications were considered depending on how to model the intra-class group correlation (i.e., correlation between random effect factors for groups within cluster). The results of simulations generally supported the adequacy of MG ML CFA and ML MIMIC for multiple-group analysis with multilevel data. The two methods did not show any notable difference in the latent group mean testing across three studies. Finally, a demonstration with real data and guidelines in selecting an appropriate approach to multilevel multiple-group analysis are provided.

  9. Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses.

    Science.gov (United States)

    Faul, Franz; Erdfelder, Edgar; Buchner, Axel; Lang, Albert-Georg

    2009-11-01

    G*Power is a free power analysis program for a variety of statistical tests. We present extensions and improvements of the version introduced by Faul, Erdfelder, Lang, and Buchner (2007) in the domain of correlation and regression analyses. In the new version, we have added procedures to analyze the power of tests based on (1) single-sample tetrachoric correlations, (2) comparisons of dependent correlations, (3) bivariate linear regression, (4) multiple linear regression based on the random predictor model, (5) logistic regression, and (6) Poisson regression. We describe these new features and provide a brief introduction to their scope and handling.

  10. Fundamentals of endoscopic surgery: creation and validation of the hands-on test.

    Science.gov (United States)

    Vassiliou, Melina C; Dunkin, Brian J; Fried, Gerald M; Mellinger, John D; Trus, Thadeus; Kaneva, Pepa; Lyons, Calvin; Korndorffer, James R; Ujiki, Michael; Velanovich, Vic; Kochman, Michael L; Tsuda, Shawn; Martinez, Jose; Scott, Daniel J; Korus, Gary; Park, Adrian; Marks, Jeffrey M

    2014-03-01

    The Fundamentals of Endoscopic Surgery™ (FES) program consists of online materials and didactic and skills-based tests. All components were designed to measure the skills and knowledge required to perform safe flexible endoscopy. The purpose of this multicenter study was to evaluate the reliability and validity of the hands-on component of the FES examination, and to establish the pass score. Expert endoscopists identified the critical skill set required for flexible endoscopy. They were then modeled in a virtual reality simulator (GI Mentor™ II, Simbionix™ Ltd., Airport City, Israel) to create five tasks and metrics. Scores were designed to measure both speed and precision. Validity evidence was assessed by correlating performance with self-reported endoscopic experience (surgeons and gastroenterologists [GIs]). Internal consistency of each test task was assessed using Cronbach's alpha. Test-retest reliability was determined by having the same participant perform the test a second time and comparing their scores. Passing scores were determined by a contrasting groups methodology and use of receiver operating characteristic curves. A total of 160 participants (17 % GIs) performed the simulator test. Scores on the five tasks showed good internal consistency reliability and all had significant correlations with endoscopic experience. Total FES scores correlated 0.73, with participants' level of endoscopic experience providing evidence of their validity, and their internal consistency reliability (Cronbach's alpha) was 0.82. Test-retest reliability was assessed in 11 participants, and the intraclass correlation was 0.85. The passing score was determined and is estimated to have a sensitivity (true positive rate) of 0.81 and a 1-specificity (false positive rate) of 0.21. The FES hands-on skills test examines the basic procedural components required to perform safe flexible endoscopy. It meets rigorous standards of reliability and validity required for high

  11. Differences in the neural correlates of frontal lobe tests.

    Science.gov (United States)

    Matsuoka, Teruyuki; Kato, Yuka; Imai, Ayu; Fujimoto, Hiroshi; Shibata, Keisuke; Nakamura, Kaeko; Yamada, Kei; Narumoto, Jin

    2018-01-01

    The Executive Interview (EXIT25), the executive clock-drawing task (CLOX1), and the Frontal Assessment Battery (FAB) are used to assess executive function at the bedside. These tests assess distinct psychometric properties. The aim of this study was to examine differences in the neural correlates of the EXIT25, CLOX1, and FAB based on magnetic resonance imaging. Fifty-eight subjects (30 with Alzheimer's disease, 10 with mild cognitive impairment, and 18 healthy controls) participated in this study. Multiple regression analyses were performed to examine the brain regions correlated with the EXIT25, CLOX1, and FAB scores. Age, gender, and years of education were included as covariates. Statistical thresholds were set to uncorrected P-values of 0.001 at the voxel level and 0.05 at the cluster level. The EXIT25 score correlated inversely with the regional grey matter volume in the left lateral frontal lobe (Brodmann areas 6, 9, 44, and 45). The CLOX1 score correlated positively with the regional grey matter volume in the right orbitofrontal cortex (Brodmann area 11) and the left supramarginal gyrus (Brodmann area 40). The FAB score correlated positively with the regional grey matter volume in the right precentral gyrus (Brodmann area 6). The left lateral frontal lobe (Brodmann area 9) and the right lateral frontal lobe (Brodmann area 46) were identified as common brain regions that showed association with EXIT25, CLOX1, and FAB based only a voxel-level threshold. The results of this study suggest that the EXIT25, CLOX1, and FAB may be associated with the distinct neural correlates of the frontal cortex. © 2018 Japanese Psychogeriatric Society.

  12. Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W

    2017-01-01

    Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2  = 0.839; p volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. Effect of Parkinson Disease on Emotion Perception Using the Persian Affective Voices Test.

    Science.gov (United States)

    Saffarian, Arezoo; Shavaki, Yunes Amiri; Shahidi, Gholam Ali; Jafari, Zahra

    2018-05-04

    Emotion perception plays a major role in proper communication with people in different social interactions. Nonverbal affect bursts can be used to evaluate vocal emotion perception. The present study was a preliminary step to establishing the psychometric properties of the Persian version of the Montreal Affective Voices (MAV) test, as well as to investigate the effect of Parkinson disease (PD) on vocal emotion perception. The short, emotional sound made by pronouncing the vowel "a" in Persian was recorded by 22 actors and actresses to develop the Persian version of the MAV, the Persian Affective Voices (PAV), for emotions of happiness, sadness, pleasure, pain, anger, disgust, fear, surprise, and neutrality. The results of the recordings of five of the actresses and five of the actors who obtained the highest score were used to generate the test. For convergent validity assessment, the correlation between the PAV and a speech prosody comprehension test was examined using a gender- and age-matched control group. To investigate the effect of the PD on emotion perception, the PAV test was performed on 28 patients with mild PD between ages 50 and 70 years. The PAV showed a high internal consistency (Cronbach's α = 0.80). A significant positive correlation was observed between the PAV and the speech prosody comprehension test. The test-retest reliability also showed the high repeatability of the PAV (intraclass correlation coefficient = 0.815, P ≤ 0.001). A significant difference was observed between the patients with PD and the controls in all subtests. The PAV test is a useful psychometric tool for examining vocal emotion perception that can be used in both behavioral and neuroimaging studies. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. The Correlation between Subjective and Objective Visual Function Test in Optic Neuropathy Patients

    Directory of Open Access Journals (Sweden)

    Ungsoo Kim

    2012-10-01

    Full Text Available Purpose: To investigate the correlation between visual acuity and quantitative measurements of visual evoked potentials (VEP, optical coherence tomography (OCT, and visual field test (VF in optic neuropathy patients. Methods: We evaluated 28 patients with optic neuropathy. Patients who had pale disc, visual acuity of less than 0.5 and abnormal visual field defect were included. At the first visit, we performed visual acuity and VF as subjective methods and OCT and VEP as objective methods. In the spectral domain OCT, rim volume, average and temporal quadrant retinal nerve fiber layer (RNFL thickness were measured. And pattern VEP (N75, P100, N135 latency, and P100 amplitude and Humphrey 24-2 visual field test (mean deviation and pattern standard deviation were obtained. Using Spearman's correlation coefficient, the correlation between visual acuity and various techniques were assessed. Results: Visual acuity was most correlated with the mean deviation of Humphrey perimetry.

  15. Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-05-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.

  16. Correlation with liver scintigram, reticuloendothelial function test, plasma endotoxin level and liver function tests in chronic liver diseases. Multivariate analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ohmoto, Kenji; Yamamoto, Shinichi; Ideguchi, Seiji and others

    1989-02-01

    Liver scintigrams with Tc-99m phytate were reviewed in a total of 64 consecutive patients, comprising 28 with chronic hepatitis and 36 with liver cirrhosis. Reticuloendothelial (RES) function, plasma endotoxin (Et) levels and findings of general liver function tests were used as reference parameters to determine the diagnostic ability of liver scintigraphy. Multivariate analyses revealed that liver scintigrams had a strong correlation with RES function and Et levels in terms of morphology of the liver and hepatic and bone marrow Tc-99m uptake. General liver function tests revealed gamma globulin to be correlated with hepatic uptake and the degree of splenogemaly on liver scintigrams; and ICG levels at 15 min to be correlated with bone marrow and splenic uptake. Accuracy of liver scintigraphy was 73% for chronic hepatitis, which was inferior to general liver function tests (83%). When both modalities were combined, diangostic accuracy increased to 95%. Liver scintigraphy seems to be useful as a complementary approach. (Namekawa, K).

  17. Testing quantum mechanics using third-order correlations

    International Nuclear Information System (INIS)

    Kinsler, P.

    1996-01-01

    Semiclassical theories similar to stochastic electrodynamics are widely used in optics. The distinguishing feature of such theories is that the quantum uncertainty is represented by random statistical fluctuations. They can successfully predict some quantum-mechanical phenomena; for example, the squeezing of the quantum uncertainty in the parametric oscillator. However, since such theories are not equivalent to quantum mechanics, they will not always be useful. Complex number representations can be used to exactly model the quantum uncertainty, but care has to be taken that approximations do not reduce the description to a hidden variable one. This paper helps show the limitations of open-quote open-quote semiclassical theories,close-quote close-quote and helps show where a true quantum-mechanical treatment needs to be used. Third-order correlations are a test that provides a clear distinction between quantum and hidden variable theories in a way analogous to that provided by the open-quote open-quote all or nothing close-quote close-quote Greenberger-Horne-Zeilinger test of local hidden variable theories. copyright 1996 The American Physical Society

  18. Measurement characteristics of the childhood Asthma-Control Test and a shortened, child-only version.

    Science.gov (United States)

    Bime, Christian; Gerald, Joe K; Wei, Christine Y; Holbrook, Janet T; Teague, William G; Wise, Robert A; Gerald, Lynn B

    2016-10-20

    The childhood Asthma-Control Test (C-ACT) is validated for assessing asthma control in paediatric asthma. Among children aged 4-11 years, the C-ACT requires the simultaneous presence of both parent and child. There is an unmet need for a tool that can be used to assess asthma control in children when parents or caregivers are not present such as in the school setting. We assessed the psychometric properties and estimated the minimally important difference (MID) of the C-ACT and a modified version, comprising only the child responses (C-ACTc). Asthma patients aged 6-11 years (n=161) from a previously completed multicenter randomised trial were included. Demographic information, spirometry and questionnaire scores were obtained at baseline and during follow-up. Participants or their guardians kept a daily asthma diary. Internal consistency reliabilities of the C-ACT and C-ACTc were 0.76 and 0.67 (Cronbach's α), respectively. Test-retest reliabilities of the C-ACT and C-ACTc were 0.72 and 0.66 (intra-class correlation), respectively. Significant correlations were noted between C-ACT scores and ACQ scores (Spearman's correlation r=-0.56, 95% CI (-0.66, -0.44), Pasthma patients aged 6-11 years, the C-ACT had good psychometric properties. The psychometric properties of a shortened child-only version (C-ACTc), although acceptable, are not as strong.

  19. Development and Testing of Screen-Based and Psychometric Instruments for Assessing Resident Performance in an Operating Room Simulator

    Directory of Open Access Journals (Sweden)

    Richard R. McNeer

    2016-01-01

    Full Text Available Introduction. Medical simulators are used for assessing clinical skills and increasingly for testing hypotheses. We developed and tested an approach for assessing performance in anesthesia residents using screen-based simulation that ensures expert raters remain blinded to subject identity and experimental condition. Methods. Twenty anesthesia residents managed emergencies in an operating room simulator by logging actions through a custom graphical user interface. Two expert raters rated performance based on these entries using custom Global Rating Scale (GRS and Crisis Management Checklist (CMC instruments. Interrater reliability was measured by calculating intraclass correlation coefficients (ICC, and internal consistency of the instruments was assessed with Cronbach’s alpha. Agreement between GRS and CMC was measured using Spearman rank correlation (SRC. Results. Interrater agreement (GRS: ICC = 0.825, CMC: ICC = 0.878 and internal consistency (GRS: alpha = 0.838, CMC: alpha = 0.886 were good for both instruments. Subscale analysis indicated that several instrument items can be discarded. GRS and CMC scores were highly correlated (SRC = 0.948. Conclusions. In this pilot study, we demonstrated that screen-based simulation can allow blinded assessment of performance. GRS and CMC instruments demonstrated good rater agreement and internal consistency. We plan to further test construct validity of our instruments by measuring performance in our simulator as a function of training level.

  20. Correlation of Descriptive Analysis and Instrumental Puncture Testing of Watermelon Cultivars.

    Science.gov (United States)

    Shiu, J W; Slaughter, D C; Boyden, L E; Barrett, D M

    2016-06-01

    The textural properties of 5 seedless watermelon cultivars were assessed by descriptive analysis and the standard puncture test using a hollow probe with increased shearing properties. The use of descriptive analysis methodology was an effective means of quantifying watermelon sensory texture profiles for characterizing specific cultivars' characteristics. Of the 10 cultivars screened, 71% of the variation in the sensory attributes was measured using the 1st 2 principal components. Pairwise correlation of the hollow puncture probe and sensory parameters determined that initial slope, maximum force, and work after maximum force measurements all correlated well to the sensory attributes crisp and firm. These findings confirm that maximum force correlates well with not only firmness in watermelon, but crispness as well. The initial slope parameter also captures the sensory crispness of watermelon, but is not as practical to measure in the field as maximum force. The work after maximum force parameter is thought to reflect cellular arrangement and membrane integrity that in turn impact sensory firmness and crispness. Watermelon cultivar types were correctly predicted by puncture test measurements in heart tissue 87% of the time, although descriptive analysis was correct 54% of the time. © 2016 Institute of Food Technologists®

  1. Psychometric testing of the Chinese version of the medical outcomes study social support survey (MOS-SSS-C).

    Science.gov (United States)

    Yu, Doris S F; Lee, Diana T F; Woo, Jean

    2004-04-01

    The purpose of this study was to assess the psychometric properties of the Chinese version of the Medical Outcomes Study Social Support Survey (MOS-SSS-C) in a sample of 110 patients. Criterion-related and construct validities of the MOS-SSS-C were evaluated by correlations with the Chinese version of the Multidimensional Perceived Social Support Survey (r =.82) and the Hospital Anxiety and Depression Scale (r = -.58). Confirmatory factor analysis affirmed the four-factor structure of the MOS-SSS-C in measuring the functional aspects of perceived social support. Cronbach's alphas for the subscales ranged from.93 to.96, whereas the alpha for the overall scale was.98. The 2-week test-retest reliability of the MOS-SSS-C as measured by the intraclass correlation coefficient was.84. The MOS-SSS-C is a psychometrically sound multidimensional measure for the evaluation of functional aspects of perceived social support by Chinese patients with chronic disease. Copyright 2004 Wiley Periodicals, Inc.

  2. The 6-min push test is reliable and predicts low fitness in spinal cord injury.

    Science.gov (United States)

    Cowan, Rachel E; Callahan, Morgan K; Nash, Mark S

    2012-10-01

    The objective of this study is to assess 6-min push test (6MPT) reliability, determine whether the 6MPT is sensitive to fitness differences, and assess if 6MPT distance predicts fitness level in persons with spinal cord injury (SCI) or disease. Forty individuals with SCI who could self-propel a manual wheelchair completed an incremental arm crank peak oxygen consumption assessment and two 6MPTs across 3 d (37% tetraplegia (TP), 63% paraplegia (PP), 85% men, 70% white, 63% Hispanic, mean age = 34 ± 10 yr, mean duration of injury = 13 ± 10 yr, and mean body mass index = 24 ± 5 kg.m). Intraclass correlation and Bland-Altman plots assessed 6MPT distance (m) reliability. Mann-Whitney U test compared 6MPT distance (m) of high and low fitness groups for TP and PP. The fitness status prediction was developed using N = 30 and validated in N = 10 (validation group (VG)). A nonstatistical prediction approach, below or above a threshold distance (TP = 445 m and PP = 604 m), was validated statistically by binomial logistic regression. Accuracy, sensitivity, and specificity were computed to evaluate the threshold approach. Intraclass correlation coefficients exceeded 0.90 for the whole sample and the TP/PP subsets. High fitness persons propelled farther than low fitness persons for both TP/PP (both P < 0.05). Binomial logistic regression (P < 0.008) predicted the same fitness levels in the VG as the threshold approach. In the VG, overall accuracy was 70%. Eighty-six percent of low fitness persons were correctly identified (sensitivity), and 33% of high fitness persons were correctly identified (specificity). The 6MPT may be a useful tool for SCI clinicians and researchers. 6MPT distance demonstrates excellent reliability and is sensitive to differences in fitness level. 6MPT distances less than a threshold distance may be an effective approach to identify low fitness in person with SCI.

  3. Accuracy and correlates of maternal recall of birthweight and gestational age

    DEFF Research Database (Denmark)

    Adegboye, Amanda Rodrigues Amorim; Heitmann, B.

    2008-01-01

    OBJECTIVE: To determine the accuracy of maternal recall of children birthweight (BW) and gestational age (GA), using the Danish Medical Birth Register (DBR) as reference and to examine the reliability of recalled BW and its potential correlates. DESIGN: Comparison of data from the DBR...... and the European Youth Heart Study (EYHS). SETTING: Schools in Odense, Denmark. POPULATION: A total of 1271 and 678 mothers of school children participated with information in the accuracy studies of BW and GA, respectively. The reliability sample of BW was composed of 359 women. METHOD: The agreement between...... the two sources was evaluated by mean differences (MD), intraclass correlation coefficient (ICC) and Bland-Altman's plots. The misclassification of the various BW and GA categories were also estimated. MAIN OUTCOME MEASURES: Differences between recalled and registered BW and GA. RESULTS: There was high...

  4. Test anxiety in medical school is unrelated to academic performance but correlates with an effort/reward imbalance.

    Science.gov (United States)

    Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte

    2017-01-01

    During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received.

  5. Correlation of index tests with smectite content determined with XRD in bentonite and smectite rich clays

    International Nuclear Information System (INIS)

    Kumpulainen, Sirpa; Kiviranta, Leena; Korkeakoski, Petri

    2012-01-01

    Document available in extended abstract form only. Various index tests are used by bentonite producers and users to assess the amount of swelling minerals in bentonites and smectite rich clays. Index tests are meant to provide relative fast and inexpensive way of testing the amount of swelling minerals, and their performance should not require sophisticated equipment. Such index tests are e.g. methylene blue absorption test, liquid limit and swelling index test (free swelling). In order to select appropriate index test to control the quality of buffer and backfill materials to be used in nuclear waste end disposal in Finland, results from various index tests were correlated with the smectite content determined with XRD and Rietveld refinement. Tests evaluated were: water absorption capacity (WAC) based on DIN 18132, swelling index (SI) based on ASTM D 5890-06, cation exchange capacity (CEC) based on Cu(II)-trien adsorption by Meier and Kahr (1999) and Ammann et al. (2005), liquid limit (LL) based on CEN ISO/TS 17892- 12:2004, methylene blue absorption (MB) based on SFS-EN 933-9, and specific surface area based on absorption of ethylene glycol monoethyl ether (EGME) described by Cerato and Lutenegger (2002). The number of samples tested was 6-25 (exact number of samples was dependent on the test method), and included natural Na-bentonites, natural Ca-bentonites, sodium activated Ca-bentonites and smectite rich clays from Wyoming/USA, Milos/Greece, Gujarat/India and Friedland/Germany. Smectite content in samples was determined after Kiviranta and Kumpulainen (2011) by x-ray diffraction (XRD), optical microscopy, chemical analyses, and full-pattern fitting with the Rietveld method using Siroquant software. Exchangeable cation composition was determined after Belyayeva (1967) and Jackson (1975). In order to achieve correlation of index test results with smectite content, water absorption capacity, liquid limit, and swelling index methods required additional information

  6. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    Science.gov (United States)

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e

  7. Full-scale locomotive dynamic collision testing and correlations : offset collisions between a locomotive and a covered hopper car (test 4).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision test with rail vehicles as part of the Federal Railroad Administrations research program on improved crashworthiness of locomotive structures. ...

  8. Reliability of cognitive tests of ELSA-Brasil, the brazilian longitudinal study of adult health

    Science.gov (United States)

    Batista, Juliana Alves; Giatti, Luana; Barreto, Sandhi Maria; Galery, Ana Roscoe Papini; Passos, Valéria Maria de Azeredo

    2013-01-01

    Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. OBJECTIVES We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. METHODS The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age) from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years). The Intraclass Correlation Coefficient (ICC) was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. RESULTS We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56), Word Recall (0.50), Word Recognition (0.35), Phonemic Verbal Fluency Test (VFT, 0.61), Semantic VFT (0.53) and Trail B (0.91). The Bland-Altman plot showed better correlation of executive function (VFT and Trail B) than of memory tests. CONCLUSIONS Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable. PMID:29213860

  9. Reliability of Cognitive Tests of ELSA-Brasil, the Brazilian Longitudinal Study of Adult Health

    Directory of Open Access Journals (Sweden)

    Juliana Alves Batista

    Full Text Available ABSTRACT Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. Objectives: We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. Methods: The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years. The Intraclass Correlation Coefficient (ICC was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. Results: We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56, Word Recall (0.50, Word Recognition (0.35, Phonemic Verbal Fluency Test (VFT, 0.61, Semantic VFT (0.53 and Trail B (0.91. The Bland-Altman plot showed better correlation of executive function (VFT and Trail B than of memory tests. Conclusions: Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable.

  10. The reliabilty of isokinetic strength measurement

    OpenAIRE

    Kadlec, Miroslav

    2011-01-01

    Title: Reliability of isometric and isokinetic strength testing in the knee flexion and extension Objectives: To compare the reliability of isometric and isokinetic testing of the knee strength in flexion and extension Methods: I used intraclass correlation coefficient and Pearson's correlation coefficient. Results: I have discovered that the reliability measured on isokinetic and isometric dynamometer is high. Furthermore the reliability of the maximum strength measurement was higher with-us...

  11. Validação da bateria "Beck" de testes de habilidades para atletas brasileiros de "rugby" em cadeira de rodas Validation of beck battery of skills tests to Brazilian players of wheelchair rugby

    Directory of Open Access Journals (Sweden)

    José Irineu Gorla

    2011-09-01

    passing, blocking, speed and long distance passing to wheelchair rugby athletes was developed in the U.S.A. by Yilla & Sherrill (1998.The aim of this study was to examine the criteria of scientific authenticity of the battery to the Brazilian athletes population. The results of two assessments with the battery (test and retest with 11 athletes (mean age 27.59 ± 5.37 years, length of lesion 8.19 ± 3.83 years, were recorded by three assessors , which allowed the analysis of objectivity, reliability and internal consistency. We used ANOVA for analysis of objectivity and linear correlation and t test for analysis of reliability and consistency. No differences were found between results from different raters (p values ranging from 0.45 to 1.00 and the values of intraclass correlation coefficient found (range r 0.78 to 0.99 p < 0.00 indicate that the battery is consistent and reliable. The results of this study indicate that the criteria of scientific authenticity to the battery are satisfied and battery can be considered a valid tool for motricity evaluation of wheelchair rugby brazilian players.

  12. Repeatability of chemical-shift-encoded water-fat MRI and diffusion-tensor imaging in lower extremity muscles in children.

    Science.gov (United States)

    Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente

    2014-06-01

    The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.

  13. Correlation between RUST assessments of fracture healing to structural and biomechanical properties.

    Science.gov (United States)

    Cooke, Margaret E; Hussein, Amira I; Lybrand, Kyle E; Wulff, Alexander; Simmons, Erin; Choi, Jeffrey H; Litrenta, Jody; Ricci, William M; Nascone, Jason W; O'Toole, Robert V; Morgan, Elise F; Gerstenfeld, Louis C; Tornetta, Paul

    2018-03-01

    Radiographic Union Score for Tibia (RUST) and modified RUST (mRUST) are radiographic tools for quantitatively evaluating fracture healing using a cortical scoring system. This tool has high intra-class correlation coefficients (ICCs); however, little evidence has evaluated the scores against the physical properties of bone healing. Closed, stabilized fractures were made in the femora of C3H/HeJ male mice (8-12 week-old) of two dietary groups: A control and a phosphate restricted diet group. Micro-computed tomography (µCT) and torsion testing were carried out at post-operative days (POD) 14, 21, 35, and 42 (n = 10-16) per group time-point. Anteroposterior and lateral radiographic views were constructed from the µCT scans and scored by five raters. The raters also indicated if the fracture were healed. ICCs were 0.71 (mRUST) and 0.63 (RUST). Both RUST scores were positively correlated with callus bone mineral density (BMD) (r = 0.85 and 0.80, p RUST scores positively correlated with callus strength (r = 0.35 and 0.26, p RUST ≥10 and had excellent relationship to structural and biomechanical metrics. Effect of delayed healing due to phosphate dietary restrictions was found at later time points with all mechanical properties (p RUST scores (p > 0.318). Clinical relevance of this study is both RUST scores showed high correlation to physical properties of healing and generally distinguished healed vs. non-healed fractures. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:945-953, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  15. Bangladesh Norms for a Gender-Specific Functional Fine Dexterity Test (FFDT

    Directory of Open Access Journals (Sweden)

    Debra K. Lindstrom-Hazel

    2016-10-01

    Full Text Available Background: Good psychometrics and cultural relevance are needed for evidence-based practice. Occupational therapy (OT assessment tools in Bangladesh have been developed outside of Bangladesh and have not been validated or normed for Bangladeshis. This normative and psychometric study was to provide culturally relevant norms for in Bangladesh for bilateral fine motor. Method: The Functional Fine Dexterity Test (FFDT consists of two functional/self-care gender-specific task instruments: a shirt with five buttons for males and a pinning board for females. Raters were trained in timing these tasks. Results: Intra-Class Correlation (ICC scores were > .85 for all rater teams. Participants were timed three times while they completed the task. Convergent validity was examined using a Pearson’s Product-Moment correlation to compare the average of three trials of the FFDT and three trials of the Nine Hole Peg Test (NHPT. Male and female norms were developed for the FFDT using descriptive statistics. The sample included 180 Bangladesh participants. Convergent validity, when compared to the NHPT, ranged from r = .4 to .67 for males (ages 18-29 and 40-49, p < .05; and r = .53 to .76 for females (aged 18-39, p < .05. FFDT norms were developed for gender and age categories. Conclusion: The FFDT is a valid test to use for evaluating fine motor dexterity in Bangladesh. This is the first OT instrument to be studied for culturally relevancy.

  16. Development and Psychometric Testing of a Scale for Evaluating Self-Management Needs of Knee Osteoarthritis (SMNKOA) in Taiwan.

    Science.gov (United States)

    Kao, Mei-Hua; Tsai, Yun-Fang

    2017-06-01

    Self-management of osteoarthritis (OA) of the knee is important for treating this chronic disease. This study developed and psychometrically tested a new instrument for measuring adult patients' self-management needs of knee osteoarthritis (SMNKOA). The theoretical framework of self-care guided the development of the 35-item SMNKOA scale. Participants ( N = 372) were purposively sampled from orthopedic clinics at medical centers in Taiwan. The content validity index was 0.83. Principal components analysis identified a three-factor solution, accounting for 53.19% of the variance. The divergent validity was -0.67; convergent validity was -0.51. Cronbach's alpha was .95, Pearson's correlation coefficient was .88, and the intraclass correlation coefficient was .95. The scale's reliability and validity supports the SMNKOA, as a tool to measure self-management needs of adults with knee OA. Nurses and other health care providers can use this instrument to evaluate knee OA patients and identify strategies for improving health-related outcomes and patient education.

  17. The King-Devick test as a concussion screening tool administered by sports parents.

    Science.gov (United States)

    Leong, D F; Balcer, L J; Galetta, S L; Liu, Z; Master, C L

    2014-02-01

    Sports-related concussion has received increasing awareness due to short- and long-term neurologic sequelae seen among athletes. The King-Devick (K-D) test captures impairment of eye movements and other correlates of suboptimal brain function. We investigated the K-D test as a screening for concussion when administered by layperson sports parents in a cohort of amateur boxers. The K-D test was administered pre-fight and post-fight by laypersons masked to the head trauma status of each athlete. Matches were watched over by a ringside physician and boxing trainer. Athletes with suspected head trauma received testing with the Military Acute Concussion Evaluation (MACE) by the ringside physician to determine concussion status. Athletes sustaining concussion were compared to the athletes screened using the K-D test. Post-fight K-D scores were lower (better) than the best baseline score (41 vs. 39.3 s, P=0.34, Wilcoxon signed-rank test), in the absence of concussion. One boxer sustained a concussion as determined by the ringside physician. This boxer was accurately identified by the layperson K-D testers due to a worsening in K-D test compared to baseline (3.2 seconds) and an increased number of errors. High levels of test-retest reliability were observed (intraclass correlation coefficient 0.90 [95% CI 0.84-0.97]). Additionally, 6 boxers who participated in multiple bouts showed no worsening of their K-D times further supporting that scores are not affected by the fatigue associated with sparring. The K-D test is a rapid sideline screening tool for concussion that can be effectively administered by non-medically trained laypersons.

  18. On the correlation between minimum thickness and central deflection during small punch test

    International Nuclear Information System (INIS)

    Kumar, Pradeep; Chattopadhyay, J.; Dutta, B.K.

    2016-01-01

    Present paper deals with a detailed study on the correlation between minimum thickness (t/t_0) and central deflection (δ/t_0). Such data are obtained during the deformation of a small punch test of miniaturized specimen. Finite element studies have been carried out to investigate the effect of various parameters which are expected to influence this correlation. The parameters under consideration are material hardening, material yield stress, coefficient of friction and initial thickness of the specimen. It is shown that the correlation remains unaffected with respect to change in material parameters. Similarly, the coefficient of friction beyond 0.2 also does not affect the correlation. However, change in thickness has significant effect on the correlation. A modification has been suggested in the existing correlation to consider the influence of thickness change. The modified correlation is then used to calculate fracture toughness using the experimental results quoted in the literature. It is shown that the modified correlation improves the fracture toughness prediction considerably.

  19. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Leinhard, Olof Dahlqvist [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences, Linkoeping (Sweden); Karlsson, Anette; Borga, Magnus [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Biomedical Engineering, Linkoeping (Sweden); Rosander, Johannes [Advanced MR Analytics AB, Linkoeping (Sweden); Toms, Andoni P. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Radiology Academy, Cotman Centre, Norwich, Norfolk (United Kingdom)

    2014-09-15

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  20. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    International Nuclear Information System (INIS)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N.; Leinhard, Olof Dahlqvist; Karlsson, Anette; Borga, Magnus; Rosander, Johannes; Toms, Andoni P.

    2014-01-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  1. The development and psychometric testing of a Disaster Response Self-Efficacy Scale among undergraduate nursing students.

    Science.gov (United States)

    Li, Hong-Yan; Bi, Rui-Xue; Zhong, Qing-Ling

    2017-12-01

    Disaster nurse education has received increasing importance in China. Knowing the abilities of disaster response in undergraduate nursing students is beneficial to promote teaching and learning. However, there are few valid and reliable tools that measure the abilities of disaster response in undergraduate nursing students. To develop a self-report scale of self-efficacy in disaster response for Chinese undergraduate nursing students and test its psychometric properties. Nursing students (N=318) from two medical colleges were chosen by purposive sampling. The Disaster Response Self-Efficacy Scale (DRSES) was developed and psychometrically tested. Reliability and content validity were studied. Construct validity was tested by exploratory and confirmatory factor analysis. Reliability was tested by internal consistency and test-retest reliability. The DRSES consisted of 3 factors and 19 items with a 5-point rating. The content validity was 0.91, Cronbach's alpha coefficient was 0.912, and the intraclass correlation coefficient for test-retest reliability was 0.953. The construct validity was good (χ 2 /df=2.440, RMSEA=0.068, NFI=0.907, CFI=0.942, IFI=0.430, pself-efficacy in disaster response for Chinese undergraduate nursing students. Copyright © 2017. Published by Elsevier Ltd.

  2. Inference and testing on the boundary in extended constant conditional correlation GARCH models

    DEFF Research Database (Denmark)

    Pedersen, Rasmus Søndergaard

    2017-01-01

    We consider inference and testing in extended constant conditional correlation GARCH models in the case where the true parameter vector is a boundary point of the parameter space. This is of particular importance when testing for volatility spillovers in the model. The large-sample properties...

  3. [The reliability of a questionnaire regarding Colombian children's physical activity].

    Science.gov (United States)

    Herazo-Beltrán, Aliz Y; Domínguez-Anaya, Regina

    2012-10-01

    Reporting the Physical Activity Questionnaire for school children's (PAQ-C) test-retest reliability and internal consistency. This was a descriptive study of 100 school-aged children aged 9 to 11 years old attending a school in Cartagena, Colombia. The sample was randomly selected. The PAQ-C was given twice, one week apart, after the informed consent forms had been signing by the children's parents and school officials. Cronbach's alpha coefficient of reliability was used for assessing internal consistency and an intra-class correlation coefficient for test-retest reliability SPSS (version 17.0) was used for statistical analysis. The questionnaire scored 0.73 internal consistencies during the first measurement and 0.78 on the second; intra-class correlation coefficient was 0.60. There were differences between boys and girls regarding both measurements. The PAQ-C had acceptable internal consistency and test-retest reliability, thereby making it useful for measuring children's self-reported physical activity and a valuable tool for population studies in Colombia.

  4. Rapidity correlations test stochastic hydrodynamics

    International Nuclear Information System (INIS)

    Zin, C; Gavin, S; Moschelli, G

    2017-01-01

    We show that measurements of the rapidity dependence of transverse momentum correlations can be used to determine the characteristic time τ π that dictates the rate of isotropization of the stress energy tensor, as well as the shear viscosity ν = η/sT . We formulate methods for computing these correlations using second order dissipative hydrodynamics with noise. Current data are consistent with τ π /ν ∼ 10 but targeted measurements can improve this precision. (paper)

  5. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    Science.gov (United States)

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  6. Six-Tube Freezable Radiator Testing and Model Correlation

    Science.gov (United States)

    Lilibridge, Sean T.; Navarro, Moses

    2012-01-01

    Freezable Radiators offer an attractive solution to the issue of thermal control system scalability. As thermal environments change, a freezable radiator will effectively scale the total heat rejection it is capable of as a function of the thermal environment and flow rate through the radiator. Scalable thermal control systems are a critical technology for spacecraft that will endure missions with widely varying thermal requirements. These changing requirements are a result of the spacecraft?s surroundings and because of different thermal loads rejected during different mission phases. However, freezing and thawing (recov ering) a freezable radiator is a process that has historically proven very difficult to predict through modeling, resulting in highly inaccurate predictions of recovery time. These predictions are a critical step in gaining the capability to quickly design and produce optimized freezable radiators for a range of mission requirements. This paper builds upon previous efforts made to correlate a Thermal Desktop(TM) model with empirical testing data from two test articles, with additional model modifications and empirical data from a sub-component radiator for a full scale design. Two working fluids were tested: MultiTherm WB-58 and a 50-50 mixture of DI water and Amsoil ANT.

  7. Correlation between the median particle size of chewed frankfurter sausage and almonds during masticatory performance test.

    Science.gov (United States)

    Sumonsiri, P; Thongudomporn, U; Paphangkorakit, J

    2018-04-27

    The correlation between chewing and gastric function is best reflected when the same food type is used during both tests. We proposed frankfurter sausage as test food for masticatory performance as it can also be used in gastric emptying test. The suitability of frankfurter sausage to determine masticatory performance, however, has never been examined. To examine the correlations between the median particle size of frankfurter sausage and almonds (as standard test food) after different numbers of chewing cycles. Twenty-seven subjects performed masticatory performance tests by chewing 2 types of test foods, that is, a piece of almond or 5-g frankfurter sausage cubes placed in a sealed latex bag, for 5 and 15 chewing cycles. For each individual, right and left sides were tested separately. Chewed samples obtained from both sides were pooled. Median particle sizes were determined using a multiple sieving method. Spearman's rank correlation was used to examine any correlation between median particle sizes of the 2 test foods after 5 and 15 cycles. Median particle sizes after 5 and 15 cycles were 2.04 ± 0.87 and 0.95 ± 0.58 mm for almonds and 4.16 ± 0.19 and 3.73 ± 0.25 mm for frankfurter sausage, respectively. Significant correlations were observed between the median particle size of chewed frankfurter sausage after 15 cycles and that of chewed almonds after 5 and 15 cycles (r = .76, P < .01 and r = .52, P = .01, respectively). Frankfurter sausage chewed for 15 cycles may be suitable for the determination of masticatory performance in conjunction with gastric emptying test. © 2018 John Wiley & Sons Ltd.

  8. Correlates of HIV testing refusal among emergency department patients in the opt-out testing era.

    Science.gov (United States)

    Setse, Rosanna W; Maxwell, Celia J

    2014-05-01

    Opt-out HIV screening is recommended by the CDC for patients in all healthcare settings. We examined correlates of HIV testing refusal among urban emergency department (ED) patients. Confidential free HIV screening was offered to 32,633 ED patients in an urban tertiary care facility in Washington, DC, during May 2007-December 2011. Demographic differences in testing refusals were examined using χ(2) tests and generalized linear models. HIV testing refusal rates were 47.7 % 95 % CI (46.7-48.7), 11.7 % (11.0-12.4), 10.7 % (10.0-11.4), 16.9 % (15.9-17.9) and 26.9 % (25.6-28.2) in 2007, 2008, 2009, 2010 and 2011 respectively. Persons 33-54 years of age [adjusted prevalence ratio (APR) 1.42, (1.36-1.48)] and those ≥ 55 years [APR 1.39 (1.31-1.47)], versus 33-54 years; and females versus males [APR 1.07 (1.02-1.11)] were more likely to refuse testing. Opt-out HIV testing is feasible and sustainable in urban ED settings. Efforts are needed to encourage testing among older patients and women.

  9. Study protocol of psychometric properties of the Spanish translation of a competence test in evidence based practice: The Fresno test

    Directory of Open Access Journals (Sweden)

    Villafafila-Ferrero Rosa

    2009-02-01

    Full Text Available Abstract Background There are few high-quality instruments for evaluating the effectiveness of Evidence-Based Practice (EBP curricula with objective outcomes measures. The Fresno test is an instrument that evaluates most of EBP steps with a high reliability and validity in the English original version. The present study has the aims to translate the Fresno questionnaire into Spanish and its subsequent validation to ensure the equivalence of the Spanish version against the English original. Methods and design The questionnaire will be translated with the back translation technique and tested in Primary Care Teaching Units in Catalonia (PCTU. Participants will be: (a tutors of Family Medicine residents (expert group; (b Family Medicine residents in their second year of the Family Medicine training program (novice group, and (c Family Medicine physicians (intermediate group. The questionnaire will be administered before and after an educational intervention. The educational intervention will be an interactive four half-day sessions designed to develop the knowledge and skills required to EBP. Responsiveness statistics used in the analysis will be the effect size, the standardised response mean and Guyatt's method. For internal consistency reliability, two measures will be used: corrected item-total correlations and Cronbach's alpha. Inter-rater reliability will be tested using Kappa coefficient for qualitative items and intra-class correlation coefficient for quantitative items and the overall score. Construct validity, item difficulty, item discrimination and feasibility will be determined. Discussion The validation of the Fresno questionnaire into different languages will enable the expansion of the questionnaire, as well as allowing comparison between countries and the evaluation of different teaching models.

  10. Correlation between liver function tests and metabolic syndrome in hepatitis-free elderly

    Directory of Open Access Journals (Sweden)

    Hung-Sheng Shang

    2015-01-01

    Full Text Available Background: We aimed to investigate the relationship between liver function tests (LFTs and metabolic syndrome (MetS as several studies have shown positive correlations between some of the LFTs, including alanine aminotransferase (ALT and γ-glutamyl transpeptidase (γ-GT, and MetS but have not fully explored the same in the elderly. Owing to the progress in public health, the aging of the general population becomes a major issue. Design: We enrolled subjects aged over 60 years who underwent routine health checkups in a Health Screening Center after excluding subjects with a history of hepatitis B or C infection, excessive alcohol consumption, liver fibrosis, cirrhosis, acute hepatitis, diabetes, hypertension, dyslipidemia, cardiovascular disease, or receiving medications for these diseases. Finally, 9,282 participants were eligible for analysis. Statistical Analysis: All data were tested for normal distribution with the Kolmogorov-Smirnov test and for homogeneity of variances with the Levene′s test. A t-test was used to evaluate the differences between the two groups. Univariate and multivariate regressions were used to observe correlations between different parameters. Receiver operating characteristic curves of each LFT were used to predict MetS. Areas under curves and 95% confidence interval were also estimated and compared. Results: With the exception of aspartate aminotransferase and α-fetal protein, the results of LFTs, including total and direct bilirubin, alkaline phosphatase (ALP, ALT, and γ-GT, were altered in the group with MetS. Furthermore, the levels of γ-GT in men and ALP in women were independently associated with all MetS components and had the highest areas under receiver operating characteristic curves. Conclusion: Abnormal LFTs are highly correlated with MetS in the hepatitis-free elderly, with levels of γ-GT in men and ALP in women being the most important factors. LFTs may represent an auxiliary tool for the

  11. The effects of repeat testing, malingering, and traumatic brain injury on visuospatial memory span

    Directory of Open Access Journals (Sweden)

    David L Woods

    2016-01-01

    Full Text Available Spatial span tests such as the Corsi Block Test (CBT and the spatial span test of the Wechsler Memory Scale are widely used to assess deficits in spatial working memory. We conducted three experiments to evaluate the test-retest reliability and clinical sensitivity of a new computerized spatial span test (C-SST that incorporates psychophysical methods to improve the precision of spatial span measurement. In Experiment 1, we analyzed C-SST test-retest reliability in 49 participants who underwent three test sessions at weekly intervals. Intraclass correlation coefficients (ICC were higher for a psychophysically derived mean span (MnS metric (0.83 than for the maximal span and total correct metrics used in traditional spatial-span tests. Response times (ReTs also showed high ICCs (0.93 that correlated negatively with MnS scores and correlated positively with response-time latencies from other tests of processing speed. Learning effects were insignificant. Experiment 2 examined the performance of Experiment 1 participants when instructed to feign symptoms of traumatic brain injury: 57% showed abnormal MnS z-scores. A MnS z-score cutoff of 3.0 correctly classified 36% of simulated malingerers and 91% of the subgroup of 11 control participants with abnormal spans. Malingerers also made more substitution errors than control participants with abnormal spans (sensitivity = 43%, specificity = 91%. In addition, malingerers showed no evidence of ReT slowing, in contrast to significant abnormalities seen on other malingered tests of processing speed. As a result, differences between ReT z-scores and z-scores on other processing speed tests showed very high sensitivity and specificity in distinguishing malingering and control participants with either normal or abnormal spans. Experiment 3 examined C-SST performance in a group of patients with predominantly mild traumatic brain injury (TBI: neither MnS nor ReT z-scores showed significant group

  12. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    International Nuclear Information System (INIS)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo

    2016-01-01

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment

  13. Correlation of uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT)and treatment response in patients with knee pain

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Geon; Hwang, Kyung Hoon; Lee, Hae Jin; Kim, Seog Gyun; Lee, Beom Koo [Gachon University Gil Hospital, Incheon (Korea, Republic of)

    2016-06-15

    To determine whether treatment response in patients with knee pain could be predicted using uptake patterns on single-photon emission computed tomography/computed tomography (SPECT/CT) images. Ninety-five patients with knee pain who had undergone SPECT/CT were included in this retrospective study. Subjects were divided into three groups: increased focal uptake (FTU), increased irregular tracer uptake (ITU), and no tracer uptake (NTU). A numeric rating scale (NRS-11) assessed pain intensity. We analyzed the association between uptake patterns and treatment response using Pearson's chi-square test and Fisher's exact test. Uptake was quantified from SPECT/CT with region of interest (ROI) counting, and an intraclass correlation coefficient (ICC) calculated agreement. We used Student' t-test to calculate statistically significant differences of counts between groups and the Pearson correlation to measure the relationship between counts and initial NRS-1k1. Multivariate logistic regression analysis determined which variables were significantly associated with uptake. The FTU group included 32 patients; ITU, 39; and NTU, 24. With conservative management, 64 % of patients with increased tracer uptake (TU, both focal and irregular) and 36 % with NTU showed positive response. Conservative treatment response of FTU was better than NTU, but did not differ from that of ITU. Conservative treatment response of TU was significantly different from that of NTU (OR 3.1; p 0.036). Moderate positive correlation was observed between ITU and initial NRS-11. Age and initial NRS-11 significantly predicted uptake. Patients with uptake in their knee(s) on SPECT/CT showed positive treatment response under conservative treatment.

  14. Normalization of ADC does not improve correlation with overall survival in patients with high-grade glioma (HGG).

    Science.gov (United States)

    Qin, Lei; Li, Angie; Qu, Jinrong; Reinshagen, Katherine; Li, Xiang; Cheng, Su-Chun; Bryant, Annie; Young, Geoffrey S

    2018-04-01

    Mixed reports leave uncertainty about whether normalization of apparent diffusion coefficient (ADC) to a within-subject white matter reference is necessary for assessment of tumor cellularity. We tested whether normalization improves the previously reported correlation of resection margin ADC with 15-month overall survival (OS) in HGG patients. Spin-echo echo-planar DWI was retrieved from 3 T MRI acquired between maximal resection and radiation in 37 adults with new-onset HGG (25 glioblastoma; 12 anaplastic astrocytoma). ADC maps were produced with the FSL DTIFIT tool (Oxford Centre for Functional MRI). 3 neuroradiologists manually selected regions of interest (ROI) in normal appearing white matter (NAWM) and in non-enhancing tumor (NT) Normalized ADC (nADC) was computed as the ratio of absolute NT ADC to NAWM ADC. Reproducibility of nADC and absolute ADC among the readers' ROI was assessed using intra-class correlation coefficient (ICC) and within-subject coefficient of variation (wCV). Correlations of ADC and nADC with OS were compared using receiver operating characteristics (ROC) analysis. A p value 0.05 was considered statistically significant. Both mean ADC and nADC differed significantly between patients subgrouped by 15-month OS (p = 0.0014 and 0.0073 respectively). wCV and ICC among the readers were similar for absolute and normalized ADC. In ROC analysis of correlation with OS, nADC did not perform significantly better than absolute ADC. Normalization does not significantly improve the correlation of absolute ADC with OS in HGG, suggesting that normalization is not necessary for clinical or research ADC analysis in HGG patients.

  15. Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts

    International Nuclear Information System (INIS)

    Park, Sang Soon; Lee, Min Woo

    2014-01-01

    Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were investigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition

  16. The effect of repeated measurements and working memory on the most comfortable level in the ANL test.

    Science.gov (United States)

    Brännström, K Jonas; Olsen, Steen Østergaard; Holm, Lucas; Kastberg, Tobias; Ibertsson, Tina

    2014-11-01

    To study the effect of a large number of repetitions on the most comfortable level (MCL) when doing the acceptable noise level (ANL) test, and explore if MCL variability is related to central cognitive processes. Twelve MCL repetitions were measured within the ANL test using interleaved methodology during one session using a non-semantic version. Phonological (PWM) and visuospatial working memory (VSWM) was measured. Thirty-two normal-hearing adults. Repeated measures ANOVA, intraclass correlations, and the coefficient of repeatability (CR) were used to assess the repeatability. Repeated measures ANOVA and CR indicated poor agreement between the two first repetitions. After excluding the first repetition, analyses showed that the MCL in the ANL test is reliable. A negative association was found between PWM and MCL variability indicating that subjects with higher PWM show less variability. The findings suggest that, after excluding the first repetition, the MCL in the ANL test is reliable. A single repetition of the MCL in the ANL test should be avoided. If an interleaved methodology is used, a single ANL repetition should be added prior to the actual testing. The findings also suggest that MCL variability is associated to PWM but not VSWM.

  17. The Dutch Technical-Tactical Tennis Test (D4T for Talent Identification and Development: Psychometric Characteristics

    Directory of Open Access Journals (Sweden)

    Kolman Nikki

    2017-01-01

    Full Text Available This study examined the test-retest reliability, validity and feasibility of the newly developed Dutch Technical-Tactical Tennis Test (D4T. This new test is relevant for talent identification and development in tennis. Thirty-two youth male tennis players (age 13.4 ± 0.5 were classified as elite (n = 15 or sub-elite (n = 17 according to their position on the national youth ranking list under 15 years (cut-off rank 50 in the Netherlands. Games, rallies and different tactical situations (i.e. offensive, neutral and defensive were simulated with a ball machine. Players had to return 72 balls to predetermined target areas. Stroke quality was recorded based on ball velocity and accuracy (VA-index, as well as percentage errors. Test-retest reliability was assessed by comparing differences between the first and second test-session (n = 10. An intraclass-correlation coefficient of .78 for the VA-index was found (p < .05, indicating excellent test-retest reliability. Independent t-tests revealed that elite players outscored sub-elite players for the VA-index, ball velocity, accuracy and percentage errors (p < .05, supporting good validity. Furthermore, a high correlation was found between the VA-index and individual positions on the youth ranking list (p = -.75; p < .001. The assessment of feasibility indicated that the D4T was applicable for instructors and coaches. In conclusion, the D4T was shown to be a reliable, valid and feasible test to measure technical-tactical characteristics of tennis performance in youth players.

  18. Sex-Dependent Individual Differences and the Correlational Relationship Between Proprioceptive and Verbal Tests

    Directory of Open Access Journals (Sweden)

    Liutsko Liudmila

    2014-09-01

    Full Text Available Introduction. The aim of the study was to analyze the relationship between proprioceptive and verbal tests on personality in both sexes separately due to existing proprioceptive differences in fine motor behavior between men and women in our previous studies [1, 2, 3]. Material and methods. 114 middle-aged participants from Belarus completed verbal tests (personality: Eysenck's EPQ, Big Five in Hromov's Russian adaptation, and Rosenberg's Self-esteem together with Proprioceptive Diagnostics of Temperament and Character (by Tous. Complementary information, such as tests of time perception, was collected and used in correlative and ANOVA analyses with the use of SPSS v.19. Results. The relationship between proprioceptive variables in personality and individual differences, time perception and the results of verbal tests were determined for each sex subgroup and discussed. ANOVA results reflected the corresponding differences and similarities between men and women in the variables of each test. Time perception was found to be significantly correlated to all five dimensions of the Big Five Test in both sexes, and both had a significant relationship to the same variables of the DP-TC test. Conclusions. Time perception can be used as an indirect indicator of personality. Existing individual and personality differences should be taken into account in coaching and education to obtain more effective results.

  19. Fetal cardiac stroke volume determination by four-dimensional ultrasound with spatio-temporal image correlation compared with two-dimensional and Doppler ultrasonography.

    Science.gov (United States)

    Rizzo, Giuseppe; Capponi, Alessandra; Cavicchioni, Ottavia; Vendola, Marianne; Arduini, Domenico

    2007-12-01

    To assess the agreement of stroke volume (SV) measured with two-dimensional (2D) ultrasonography with Doppler capability (vs) four-dimensional (4D) with spatiotemporal image correlation (STIC) in normal and growth restricted fetuses. 2D Doppler and 4D STIC were used to measure SV of 40 normal fetuses at 20 to 22 and 28 to 32 weeks, and 16 growth-restricted fetuses at 26 to 34 weeks of gestation. Intraclass correlation was used to evaluate the agreement between left and right SV obtained by the two techniques, and proportionate Bland-Altman plots constructed. The time necessary to obtain SV was analyzed. The intraclass correlation coefficient between 2D Doppler and 4D STIC measurements for the left ventricle were 0.977 and 0.980 for the right ventricle. The proportionate limits of agreement between the two methods were 18.7 to 23.9% for the left ventricle and - 20.9 to 21.7% for the right ventricle. The time necessary to measure SV was significantly shorter with 4D STIC (3.1 (vs) 7.9 min p < 0.0001) than with 2D Doppler. There is a good agreement between SV measured either by 2D Doppler or by 4D STIC. The 4D STIC represents a simple and rapid technique to estimate fetal SV and promises to become the method of choice. Copyright (c) 2007 John Wiley & Sons, Ltd.

  20. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    Science.gov (United States)

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  1. Transcultural adaptation and psychometric properties of Spanish version of Pregnancy Physical Activity Questionnaire: the PregnActive project.

    Science.gov (United States)

    Oviedo-Caro, Miguel Ángel; Bueno-Antequera, Javier; Munguía-Izquierdo, Diego

    2018-03-19

    To transculturally adapt the Spanish version of Pregnancy Physical Activity Questionnaire (PPAQ) analyzing its psychometric properties. The PPAQ was transculturally adapted into Spanish. Test-retest reliability was evaluated in a subsample of 109 pregnant women. The validity was evaluated in a sample of 208 pregnant women who answered the questionnaire and wore the multi-sensor monitor for 7 valid days. The reliability (intraclass correlation coefficient), concordance (concordance correlation coefficient), correlation (Pearson correlation coefficient), agreement (Bland-Altman plots) and relative activity levels (Jonckheere-Terpstra test) between both administrations and methods were examined. Intraclass correlation coefficients between both administrations were good for all categories except transportation. A low but significant correlation was found for total activity (light and above) whereas no correlation was found for other intensities between both methods. Relative activity levels analysis showed a significant linear trend for increased total activity between both methods. Spanish version of PPAQ is a brief and easily interpretable questionnaire with good reliability and ability to rank individuals, and poor validity compared with multi-sensor monitor. The use of PPAQ provides information of pregnancy-specific activities in order to establish physical activity levels of pregnant women and adapt health promotion interventions. Copyright © 2018 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Correlation test to assess low-level processing of high-density oligonucleotide microarray data

    Directory of Open Access Journals (Sweden)

    Bergh Jonas

    2005-03-01

    Full Text Available Abstract Background There are currently a number of competing techniques for low-level processing of oligonucleotide array data. The choice of technique has a profound effect on subsequent statistical analyses, but there is no method to assess whether a particular technique is appropriate for a specific data set, without reference to external data. Results We analyzed coregulation between genes in order to detect insufficient normalization between arrays, where coregulation is measured in terms of statistical correlation. In a large collection of genes, a random pair of genes should have on average zero correlation, hence allowing a correlation test. For all data sets that we evaluated, and the three most commonly used low-level processing procedures including MAS5, RMA and MBEI, the housekeeping-gene normalization failed the test. For a real clinical data set, RMA and MBEI showed significant correlation for absent genes. We also found that a second round of normalization on the probe set level improved normalization significantly throughout. Conclusion Previous evaluation of low-level processing in the literature has been limited to artificial spike-in and mixture data sets. In the absence of a known gold-standard, the correlation criterion allows us to assess the appropriateness of low-level processing of a specific data set and the success of normalization for subsets of genes.

  3. Correlation of accelerometry with clinical balance tests in older fallers and non-fallers.

    LENUS (Irish Health Repository)

    O'Sullivan, Maura

    2012-02-01

    BACKGROUND: falls are a common cause of injury and decreased functional independence in the older adult. Diagnosis and treatment of fallers require tools that accurately assess physiological parameters associated with balance. Validated clinical tools include the Berg Balance Scale (BBS) and the Timed Up and Go test (TUG); however, the BBS tends to be subjective in nature, while the TUG quantifies an individuals functional impairment but requires further subjective evaluation for balance assessment. Other quantitative alternatives to date require expensive, sophisticated equipment. Measurement of the acceleration of centre of mass, with relatively inexpensive, lightweight, body-mounted accelerometers is a potential solution to this problem. OBJECTIVES: to determine (i) if accelerometry correlates with standard clinical tests (BBS and TUG), (ii) to characterise accelerometer responses to increasingly difficult challenges to balance and (iii) to characterise acceleration patterns between fallers and non-fallers. Study design and setting: torso accelerations were measured at the level of L3 using a tri-axial accelerometer under four conditions; standing unsupported with eyes open (EO), eyes closed (EC) and on a mat with eyes open (MAT EO) and closed (MAT EC). Older patients (n = 21, 8 males, 13 females) with a mean age of 78 (SD +\\/- 7.6) years who attended a day hospital were recruited for this study. Patients were identified as fallers or non-fallers based on a comprehensive falls history. MEASUREMENTS: Spearman\\'s rank correlation analysis examined the relationship between acceleration root mean square (RMS) data and the BBS while Pearson\\'s correlation was used with TUG scores. Differences in accelerometer RMS between fallers and non-fallers and between test conditions were examined using t-test and non-parametric alternatives where appropriate. RESULTS: there was a stepwise increase in accelerometer RMS with increasing task complexity, and the accelerometer

  4. [Cognition-correlation indices of gender schema: tests of validity].

    Science.gov (United States)

    Ishida, E

    1994-02-01

    Four-hundred and seventy-seven subjects evaluated a set of traits and behaviors in terms of how masculine and feminine they were and in terms of how well they represented their real and ideal self-images. Within-individual correlation coefficients between these evaluations were proposed as measures of psychological gender schemata, because they would represent the degree of matching between the subjects' gender-image and ideal/real self-images of gender-related attributes. The present study aims at examining the construct validity of these measures, by testing them to psychological variables that are known to reflect gender identity. The individual difference variables used as criteria were (a) satisfaction with one's own sex, (b) general happiness, (c) self-esteem (d) gender-conflict, and (e) school and occupational achievement need. Correlations between the gender-schema indices and the criteria variables supported the construct validity of those measures. Advantages of the present measurement over the conventional simple trait approach, such as BSRI, or PAQ are discussed.

  5. Correlation of volumetric and fractal measurements of brain atrophy with neuropsychological tests in patients with dementive disorders

    International Nuclear Information System (INIS)

    Czarnecka, A.; Sasiadek, M.; Filarski, J.

    2008-01-01

    Brain atrophy is one of the features of the dementive diseases, but also of other neurodegenerative disorders as well as physiological brain aging. The aim of the study was to define the relationship between the brain atrophy measurements and the degree of the severity of dementive process based on the neuropsychological tests (MMSE and Clock Drawing Test). In 68 patients with diagnosed impairment of cognitive functions due to dementia, neuropsychological tests (MMSE and Clock Drawing Test) and CT studies were performed. On the basis of CT images we evaluated cortical and subcortical atrophy with 3 methods; visual, semiautomatic (volumetric) and automatic method based on fractal geometry calculations; the latter was characterized by very short time of measurements. The correlation between neuropsychological tests and brain atrophy measurements has been assessed using Pearson's correlation test. No statistical correlation was found between the results of neuropsychological tests and measurements of the brain atrophy (both cortical and subcortical) using all three methods mentioned above. Single measurement of the generalized cortical and subcortical atrophy is not correlated with the results of neuropsychological tests. In our opinion, these measurements might be valuable in follow-up of the dementive process to compare progression of the atrophic changes with the changes of the neuropsychological tests results, especially using very quick automatic method, supplemented by local atrophy measurements. (authors)

  6. Test-retest reliability and minimal detectable change scores for sit-to-stand-to-sit tests, the six-minute walk test, the one-leg heel-rise test, and handgrip strength in people undergoing hemodialysis.

    Science.gov (United States)

    Segura-Ortí, Eva; Martínez-Olmos, Francisco José

    2011-08-01

    Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.

  7. Comparison of muscle/lean mass measurement methods: correlation with functional and biochemical testing.

    Science.gov (United States)

    Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N

    2018-03-01

    DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.

  8. Validation of the portuguese version of the tampa scale for kinesiophobia heart (TSK-SV heart

    Directory of Open Access Journals (Sweden)

    Gabriela Lima de Melo Ghisi

    Full Text Available ABSTRACT Introduction: It has been shown that kinesiophobia has a negative influence on the outcomes of cardiac rehabilitation and consequently is important for the clinical setting. Objective: The objective of this study was to translate, culturally adapt, and psychometrically validate the Tampa Scale for Kinesiophobia Heart (TSK-SV Heart to Brazilian Portuguese. Methods: The Portuguese version was tested in 300 patients in cardiac rehabilitation. Test-retest reliability was assessed by intraclass correlation coefficient, internal consistency by Cronbach’s alpha, and criterion validity was assessed with respect to patients’ education, income, duration of cardiac rehabilitation, and sex. Results: After intraclass correlation coefficient analysis, one item was excluded. All four areas were considered internally consistent (α >0.7. Significant differences between mean total scores and income (p 37. Conclusions: The Brazilian Portuguese version of TSK-SV Heart demonstrated sufficient reliability, consistency and validity, supporting its use in future studies.

  9. Testing Proposed Correlations Between Olduvai Gorge and Laetoli, Tanzania Using Tephra Composition

    Science.gov (United States)

    McHenry, L. J.

    2006-12-01

    Olduvai Gorge and Laetoli are well-known Plio-Pleistocene archaeological sites located 30 km apart in Tanzania. Both received volcanic input from the nearby Ngorongoro Volcanic Highlands (NVH), and together provide a sedimentary and volcanic record from about 4.3 Ma to the Holocene. Previous researchers have proposed likely temporal correlations between the two sites, using both faunal and volcanic evidence. Direct tephra correlation between these sites could create a regional stratigraphic framework for their fossil and paleoecological records. Here, one of the proposed correlations is tested using geochemical fingerprinting. The fossiliferous Laetolil and Ndolanya beds of Laetoli predate the deposition of the Olduvai Beds, however recent 39Ar/40Ar SCLF age dating has shown potential temporal overlap between the Naibadad (2.23-1.93 +/- 0.02; Mangea, 1993) and Olpiro Beds (2.06-2.01 +/- 0.03; Manega 1993) at Laetoli with the Naabi Ignimbrite (2.029 +/- 0.005 Ma, Walter et al. 1992) and lower Bed I at Olduvai. Both the Naibadad bed and lower Bed I also contain fresh quartz-bearing tephra, which can be used for geochemical correlation. Three Naibadad tuffs and five lower Bed I tuffs (Naabi Ignimbrite, coarse feldspar crystal tuff (CFCT), Tuff IA, and two ignimbrites near Ngorongoro) were analyzed by electron microprobe for phenocryst and glass composition and compared to test for possible correlations. Certain mineralogical features made such a correlation unlikely. None of the lower Bed I tuffs analyzed contain significant plagioclase, which is present in all of the Naibadad tuffs analyzed. One Naibadad tuff has a bimodal glass composition indistinguishable from the CFCT, however the CFCT is rich in hornblende, while this Naibadad tuff contains none. This mineralogical difference highlights the need for mineralogical in addition to glass geochemical data for tephra correlation. Ngorongoro crater is the likely source for the Naibadad and lower Bed I tuffs because it

  10. Reliability of a questionnaire on substance use among adolescent students, Brazil.

    Science.gov (United States)

    Machado Neto, Adelmo de Souza; Andrade, Tarcisio Matos; Fernandes, Gilênio Borges; Zacharias, Helder Paulo; Carvalho, Fernando Martins; Machado, Ana Paula Souza; Dias, Ana Carmen Costa; Garcia, Ana Carolina Rocha; Santana, Lauro Reis; Rolin, Carlos Eduardo; Sampaio, Cyntia; Ghiraldi, Gisele; Bastos, Francisco Inácio

    2010-10-01

    To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. The questionnaire reliability was found to be satisfactory in the population studied.

  11. [Alusti test: New scale for assessment of physical performance in the geriatric population].

    Science.gov (United States)

    Calvo Aguirrey, Juan José; Alustiza Navarro, Josu; Uranga Zaldúa, Joana; Sarasqueta Eizaguirre, Cristina; Bueno Yáñez, Olga

    2018-06-11

    Physical and psychological functional conditions are key factors in the elderly population. Many evaluation tools are available, but they cannot be applied to the whole geriatric population. The use Alusti Test is presented. This test consists of 2versions, which enable it to encompass this wide and complex population spectrum. A prospective study with the institutionalised, hospitalised, and community population, was conducted between September and December 2016. A comparative analysis was conducted using the Barthel Index (BI), Gait Speed Test (GST), Timed «Up & Go» Test (TUG), Short Physical Performance Battery (SPPB), and Tinetti Test. A total of 363 subjects were enrolled (mean age: 83.25 years), with varying levels of functional and cognitive conditions. The test was simple and quick to apply (3-6min), 100% applicable and usable with broad floor and ceiling effects (0-100 points) with an intraclass correlation coefficient (ICC) that shows a high inter-observer reliability (ICC = 0.99), and a good correlation in its full version with BI (ICC = 0.86) (95% CI: 0.82-0.88), and the Tinetti test (ICC = 0.76; 95% CI: 0.71-0.81), as well as in the abbreviated version BI (ICC = 0.71; 95% CI: 0.65-0.75) and Tinetti Test (ICC = 0.90; 95% CI: 0.88-0.92). This allows the variation of the functional condition to be measured, which in our sample showed an increase of 10.9%, after a period of hospital admission. It is considered that Alusti test meets the requirements for physical performance assessment in the whole the geriatric population. The highest level of accuracy is given by the Tinetti test, which has greater applicability. Copyright © 2018 SEGG. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Correlation and agreement of a digital and conventional method to measure arch parameters.

    Science.gov (United States)

    Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika

    2018-01-01

    The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.

  13. Validity, Reliability, and Performance Determinants of a New Job-Specific Anaerobic Work Capacity Test for the Norwegian Navy Special Operations Command.

    Science.gov (United States)

    Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls

    2016-02-01

    Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants

  14. Robust D-optimal designs under correlated error, applicable invariantly for some lifetime distributions

    International Nuclear Information System (INIS)

    Das, Rabindra Nath; Kim, Jinseog; Park, Jeong-Soo

    2015-01-01

    In quality engineering, the most commonly used lifetime distributions are log-normal, exponential, gamma and Weibull. Experimental designs are useful for predicting the optimal operating conditions of the process in lifetime improvement experiments. In the present article, invariant robust first-order D-optimal designs are derived for correlated lifetime responses having the above four distributions. Robust designs are developed for some correlated error structures. It is shown that robust first-order D-optimal designs for these lifetime distributions are always robust rotatable but the converse is not true. Moreover, it is observed that these designs depend on the respective error covariance structure but are invariant to the above four lifetime distributions. This article generalizes the results of Das and Lin [7] for the above four lifetime distributions with general (intra-class, inter-class, compound symmetry, and tri-diagonal) correlated error structures. - Highlights: • This paper presents invariant robust first-order D-optimal designs under correlated lifetime responses. • The results of Das and Lin [7] are extended for the four lifetime (log-normal, exponential, gamma and Weibull) distributions. • This paper also generalizes the results of Das and Lin [7] to more general correlated error structures

  15. Comparison of two methods for calculating the mean vascularization index of ovarian stroma on the basis of spatio-temporal image correlation high-definition flow technology.

    Science.gov (United States)

    Kudla, Marek J; Kandzia, Tomasz; Alcázar, Juan Luis

    2013-11-01

    The aim of our study was to determine the agreement between two different methods for calculating the mean vascularization index (VI) of ovarian stroma using spatio-temporal image correlation-high definition flow (STIC-HDF) technology. Stored 4-D STIC-HDF volume data for ovaries of 34 premenopausal women were assessed retrospectively. We calculated the mean VI from the VI values derived for each 3-D volume within the STIC sequence. Then, the examiner subjectively selected the two volumes with the highest and lowest color signals, respectively. We averaged these two values. Agreement between VI measurements was estimated by calculating intra-class correlation coefficients. The intra-class correlation coefficient for the VI was 0.999 (95% confidence interval: 0.999-1.000). The mean time needed to calculate the mean VI using the entire 4-D STIC sequence was significantly longer than the mean time needed to calculate the average value from the volumes with the highest and lowest color signals determined by the operator (p < 0001). We conclude that there is significant agreement between the two methods. Calculating the average VI from the highest and lowest values is less time consuming than calculating the mean VI from the complete STIC sequence. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Intracellular lipid in papillary renal cell carcinoma (pRCC): T2 weighted (T2W) MRI and pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Schieda, Nicola; Van der Pol, Christian B.; Moosavi, Bardia; McInnes, Matthew D.F. [The Ottawa Hospital, The University of Ottawa, Department of Medical Imaging, Ottawa, Ontario (Canada); Mai, Kien T.; Flood, Trevor A. [The Ottawa Hospital, The University of Ottawa, Department of Anatomical Pathology, Ottawa, Ontario (Canada)

    2015-07-15

    To evaluate if pRCCs demonstrate intracellular lipid (i-lipid) at chemical-shift (CS) MRI, and assess T2W-MRI and pathologic characteristics. Sixty-two patients with a pRCC diagnosis underwent MRI over 11 years (IRB-approved). Two radiologists independently assessed for presence of i-lipid on CS-MRI and homogeneity on T2W-MRI. Inter-observer agreement was assessed via an intraclass correlation and results were compared using the Chi-square test. Discordant cases were reviewed to establish consensus. T2W SI-ratios (SI.tumor/SI.kidney) and CS-SI index were compared using independent t-tests and Spearman correlation. Two pathologists re-evaluated the histopathology. Nine of the 62 pRCCs (14.5 %) demonstrated i-lipid; agreement was moderate (ICC = 0.63). Pathology review depicted clear cells in four tumours and foamy histiocytes in five tumours. 25.8-35.4 % (ICC = 0.65) of tumours were homogeneous on T2W-MRI. No pRCC with i-lipid was considered homogeneous (p = 0.01-0.04). Overall, T2W SI-ratio and CS-SI index were 0.89 (±0.29) and -3.63 % (-7.27 to 11.42). pRCC with i-lipid had significantly higher T2W SI-ratio (p = 0.003). There was a correlation between the CS-SI index and T2W SI-ratio, (r = 0.44, p < 0.001). Intracellular lipid is uncommonly detected in pRCCs due to clear cell changes and foamy histiocytes. These tumours are associated with heterogeneously-increased SI in T2W-MRI. (orig.)

  17. Test-retest reliability of an fMRI paradigm for studies of cardiovascular reactivity.

    Science.gov (United States)

    Sheu, Lei K; Jennings, J Richard; Gianaros, Peter J

    2012-07-01

    We examined the reliability of measures of fMRI, subjective, and cardiovascular reactions to standardized versions of a Stroop color-word task and a multisource interference task. A sample of 14 men and 12 women (30-49 years old) completed the tasks on two occasions, separated by a median of 88 days. The reliability of fMRI BOLD signal changes in brain areas engaged by the tasks was moderate, and aggregating fMRI BOLD signal changes across the tasks improved test-retest reliability metrics. These metrics included voxel-wise intraclass correlation coefficients (ICCs) and overlap ratio statistics. Task-aggregated ratings of subjective arousal, valence, and control, as well as cardiovascular reactions evoked by the tasks showed ICCs of 0.57 to 0.87 (ps reliability. These findings support using these tasks as a battery for fMRI studies of cardiovascular reactivity. Copyright © 2012 Society for Psychophysiological Research.

  18. Sport-specific endurance plank test for evaluation of global core muscle function.

    Science.gov (United States)

    Tong, Tom K; Wu, Shing; Nie, Jinlei

    2014-02-01

    To examine the validity and reliability of a sports-specific endurance plank test for the evaluation of global core muscle function. Repeated-measures study. Laboratory environment. Twenty-eight male and eight female young athletes. Surface electromyography (sEMG) of selected trunk flexors and extensors, and an intervention of pre-fatigue core workout were applied for test validation. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and the measurement bias ratio */÷ ratio limits of agreement (LOA) were calculated to assess reliability and measurement error. Test validity was shown by the sEMG of selected core muscles, which indicated >50% increase in muscle activation during the test; and the definite discrimination of the ∼30% reduction in global core muscle endurance subsequent to a pre-fatigue core workout. For test-retest reliability, when the first attempt of three repeated trials was considered as familiarisation, the ICC was 0.99 (95% CI: 0.98-0.99), CV was 2.0 ± 1.56% and the measurement bias ratio */÷ ratio LOA was 0.99 */÷ 1.07. The findings suggest that the sport-specific endurance plank test is a valid, reliable and practical method for assessing global core muscle endurance in athletes given that at least one familiarisation trial takes place prior to measurement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. RECONSTRUCTING REDSHIFT DISTRIBUTIONS WITH CROSS-CORRELATIONS: TESTS AND AN OPTIMIZED RECIPE

    International Nuclear Information System (INIS)

    Matthews, Daniel J.; Newman, Jeffrey A.

    2010-01-01

    Many of the cosmological tests to be performed by planned dark energy experiments will require extremely well-characterized photometric redshift measurements. Current estimates for cosmic shear are that the true mean redshift of the objects in each photo-z bin must be known to better than 0.002(1 + z), and the width of the bin must be known to ∼0.003(1 + z) if errors in cosmological measurements are not to be degraded significantly. A conventional approach is to calibrate these photometric redshifts with large sets of spectroscopic redshifts. However, at the depths probed by Stage III surveys (such as DES), let alone Stage IV (LSST, JDEM, and Euclid), existing large redshift samples have all been highly (25%-60%) incomplete, with a strong dependence of success rate on both redshift and galaxy properties. A powerful alternative approach is to exploit the clustering of galaxies to perform photometric redshift calibrations. Measuring the two-point angular cross-correlation between objects in some photometric redshift bin and objects with known spectroscopic redshift, as a function of the spectroscopic z, allows the true redshift distribution of a photometric sample to be reconstructed in detail, even if it includes objects too faint for spectroscopy or if spectroscopic samples are highly incomplete. We test this technique using mock DEEP2 Galaxy Redshift survey light cones constructed from the Millennium Simulation semi-analytic galaxy catalogs. From this realistic test, which incorporates the effects of galaxy bias evolution and cosmic variance, we find that the true redshift distribution of a photometric sample can, in fact, be determined accurately with cross-correlation techniques. We also compare the empirical error in the reconstruction of redshift distributions to previous analytic predictions, finding that additional components must be included in error budgets to match the simulation results. This extra error contribution is small for surveys that sample

  20. Testing Game-Based Performance in Team-Handball.

    Science.gov (United States)

    Wagner, Herbert; Orwat, Matthias; Hinz, Matthias; Pfusterschmied, Jürgen; Bacharach, David W; von Duvillard, Serge P; Müller, Erich

    2016-10-01

    Wagner, H, Orwat, M, Hinz, M, Pfusterschmied, J, Bacharach, DW, von Duvillard, SP, and Müller, E. Testing game-based performance in team-handball. J Strength Cond Res 30(10): 2794-2801, 2016-Team-handball is a fast paced game of defensive and offensive action that includes specific movements of jumping, passing, throwing, checking, and screening. To date and to the best of our knowledge, a game-based performance test (GBPT) for team-handball does not exist. Therefore, the aim of this study was to develop and validate such a test. Seventeen experienced team-handball players performed 2 GBPTs separated by 7 days between each test, an incremental treadmill running test, and a team-handball test game (TG) (2 × 20 minutes). Peak oxygen uptake (V[Combining Dot Above]O2peak), blood lactate concentration (BLC), heart rate (HR), sprinting time, time of offensive and defensive actions as well as running intensities, ball velocity, and jump height were measured in the game-based test. Reliability of the tests was calculated using an intraclass correlation coefficient (ICC). Additionally, we measured V[Combining Dot Above]O2peak in the incremental treadmill running test and BLC, HR, and running intensities in the team-handball TG to determine the validity of the GBPT. For the test-retest reliability, we found an ICC >0.70 for the peak BLC and HR, mean offense and defense time, as well as ball velocity that yielded an ICC >0.90 for the V[Combining Dot Above]O2peak in the GBPT. Percent walking and standing constituted 73% of total time. Moderate (18%) and high (9%) intensity running in the GBPT was similar to the team-handball TG. Our results indicated that the GBPT is a valid and reliable test to analyze team-handball performance (physiological and biomechanical variables) under conditions similar to competition.

  1. The correlation of symptoms, pulmonary function tests and exercise testing with high-resolution computed tomography in patients with idiopathic interstitial pneumonia in a tertiary care hospital in South India.

    Science.gov (United States)

    Isaac, Barney Thomas Jesudason; Thangakunam, Balamugesh; Cherian, Rekha A; Christopher, Devasahayam Jesudas

    2015-01-01

    For the follow-up of patients with idiopathic interstitial pneumonias (IIP), it is unclear which parameters of pulmonary function tests (PFT) and exercise testing would correlate best with high-resolution computed tomography (HRCT).. To find out the correlation of symptom scores, PFTs and exercise testing with HRCT scoring in patients diagnosed as idiopathic interstitial pneumonia. Cross-sectional study done in pulmonary medicine outpatients department of a tertiary care hospital in South India. Consecutive patients who were diagnosed as IIP by a standard algorithm were included into the study. Cough and dyspnea were graded for severity and duration. Pulmonary function tests and exercise testing parameters were noted. HRCT was scored based on an alveolar score, an interstitial score and a total score. The HRCT was correlated with each of the clinical and physiologic parameters. Pearson's/Spearman's correlation coefficient was used for the correlation of symptoms and parameters of ABG, PFT and 6MWT with the HRCT scores. A total of 94 patients were included in the study. Cough and dyspnea severity (r = 0.336 and 0.299), FVC (r = -0.48), TLC (r = -0.439) and DLCO and distance saturation product (DSP) (r = -0.368) and lowest saturation (r = -0.324) had significant correlation with total HRCT score. Among these, DLCO, particularly DLCO corrected % of predicted, correlated best with HRCT score (r = -0.721).. Symptoms, PFT and exercise testing had good correlation with HRCT. DLCO corrected % of predicted correlated best with HRCT.

  2. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  3. Validity and cross-cultural adaptation of the persian version of the oxford elbow score.

    Science.gov (United States)

    Ebrahimzadeh, Mohammad H; Kachooei, Amir Reza; Vahedi, Ehsan; Moradi, Ali; Mashayekhi, Zeinab; Hallaj-Moghaddam, Mohammad; Azami, Mehran; Birjandinejad, Ali

    2014-01-01

    Oxford Elbow Score (OES) is a patient-reported questionnaire used to assess outcomes after elbow surgery. The aim of this study was to validate and adapt the OES into Persian language. After forward-backward translation of the OES into Persian, a total number of 92 patients after elbow surgeries completed the Persian OES along with the Persian DASH and SF-36. To assess test-retest reliability, 31 randomly selected patients (34%) completed the Persian OES again after three days while abstaining from all forms of therapeutic regimens. Reliability of the Persian OES was assessed by measuring intraclass correlation coefficient (ICC) for test-retest reliability and Cronbach's alpha for internal consistency. Spearman's correlation coefficient was used to test the construct validity. Cronbach's alpha coefficient was 0.92 showing excellent reliability. Cronbach's alpha for function, pain, and social-psychological subscales was 0.95, 0.86, and 0.85, respectively. Intraclass correlation coefficient (ICC) was 0.85 for the overall questionnaire and 0.90, 0.76, and 0.75 for function, pain, and social-psychological subscales, respectively. Construct validity was confirmed as the Spearman correlation between OES and DASH was 0.80. Persian OES is a valid and reliable patient-reported outcome measure to assess postsurgical elbow status in Persian speaking population.

  4. Is the Screening Test of the French Version of the Dementia Quality of Life Questionnaire Indispensable

    Directory of Open Access Journals (Sweden)

    A. Wolak

    2011-04-01

    Full Text Available The aim of this study was to evaluate the usefulness of the screening questions in the French version of the Dementia Quality of Life (DQoL questionnaire. To assess the psychometric properties of the French DQoL, 155 patients with mild-to-moderate dementia were recruited. Here, we compared the psychometric properties of the instrument between patients who passed the screening test (n = 109 and the whole study population (n = 155. The French DQoL version showed a good test-retest reliability at a 2-week interval (0.95 ≤ intraclass correlation coefficients ≤ 1.0, and an average internal consistency (0.58 ≤ Cronbach’s α ≤ 0.87 for the 2 study groups. Significant differences were observed in the 2 groups for 4 dimensions of the DQoL regarding dementia severity (Cornell scale, and for 3 dimensions evaluating depression (MMSE. Convergent validity with the Duke Health Profile revealed many significant correlations between dimensions not only in the 109 patients, but also in the whole study population. Our study demonstrated that patients who failed the screening procedure nonetheless seemed to be able to answer the DQoL questionnaire, the whole study group showing acceptable psychometric properties.

  5. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  6. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  7. Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

    Science.gov (United States)

    Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung; Lee, Ran

    2016-01-01

    Purpose To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was 0.68±0.18 g/kg/d; according to age, the dose was 0.73±0.16 g/kg/d (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation. PMID:27738600

  8. Italian validation of the Purpose In Life (PIL) test and the Seeking Of Noetic Goals (SONG) test in a population of cancer patients.

    Science.gov (United States)

    Brunelli, C; Bianchi, E; Murru, L; Monformoso, P; Bosisio, M; Gangeri, L; Miccinesi, G; Scrignaro, M; Ripamonti, C; Borreani, C

    2012-11-01

    The first instruments developed to evaluate specific logotherapeutic dimensions were the Purpose In Life (PIL) and the Seeking Of Noetic Goals (SONG) tests, designed to reflect Frankl's concepts of, respectively, meaning in life attainment and will to meaning. This study aims to perform the Italian cultural adaptation and the psychometric validation of the PIL and SONG questionnaires. We administered the PIL and SONG, culturally adapted into the Italian language, to 266 cancer patients. The psychometric validation appraised construct validity, internal consistency, test-retest reliability, known-group validity, and convergent validity of the two questionnaires with respect to one another. The factorial analysis indicates that the original single-factor solution can be maintained for both instruments (proportion of variance explained by the first factor 77% and 71% for the PIL and SONG, respectively). The results show excellent internal consistency (Cronbach's alpha of 0.91 for the PIL and 0.90 for the SONG) and test-retest reliability (intraclass correlation coefficient of 0.92 for the PIL and 0.81 for the SONG). As expected, males, believers, patients nearer to the diagnosis, and patients not undergoing psychological therapy have higher PIL and lower SONG scores, while expectations for age were not confirmed. The average level for the PIL was 107.3, while for the SONG, it was 66.1, and a negative correlation (-0.47) between PIL and SONG scores indicates good convergent validity of the two instruments. Italian versions of the PIL and SONG are adequate and reliable self-report instruments for evaluating purpose in life and the motivation to find purpose for cancer patient populations.

  9. Air trapping on HRCT in asthmatics: correlation with pulmonary function test

    International Nuclear Information System (INIS)

    Hwang, Jung Hwa; Cha, Chull Hee; Park, Jai Soung; Kim, Young Beom; Lee, Hae Kyung; Choi, Deuk Lin; Kim, Kyung Ho; Park, Choon Sik

    1997-01-01

    To evaluate on the basis of the pulmonary function test the correlation between the extent of air trapping on HRCT with the severity of airway obstruction and also to identify the prognostic effect of the extent of air trapping after treatment of asthma. Thirty five patients with clinically diagnosed bronchial asthma and air trapping, as seen on HRCT, were included in this study. We quantitatively analysed on HRCT the extent of air trapping and then statistically compared this with the clinical parameters of the pulmonary function test. We classified the patients into two groups on the basis of the pulmonary function test and clinical status : Group 1 (N=35), the total number of asthmatic patients; Group 2 (N=18), relatively stable asthmatics without acute asthmatic attack who showed FEV1 of more than 80% of the predicted value. Using the functional paramenters of PEFR, one of the obijective indicators of improvement in airway obstruction, we also classified the patients into three groups on the basis of interval between treatment and clinical improvement. The result of this was as follows : group 1, asymptomatic group (initial PEFR within normal limit, N=7); group 2, early responder (improvement of PEFR within three hospital days, N=18); group 3, late responder (improvement of PEFR within fourteen hospital days should there be a number here). Using HRCT, we then statistically analysed the differences between the three groups in the extent of air trapping. Among the total of 35 asthmatics, the extent of air trapping on HRCT showed significant correlation with FEV1 (r= -0.6161, p < 0.001) and MEFR (r= -0.6012, p < 0.001). Among the relatively stable asthmatics who showed FEV1 more than 80% of the predicted value, MEFR (r= -0.7553, p < 0.001) and FEF75 (r= -0.7529, p=0.012) showed statistically significant correlation with the extent of air trapping on HRCT, but there was no significant correlation between air trapping on HRCT and FEV1. In the three groups of

  10. Air trapping on HRCT in asthmatics: correlation with pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jung Hwa; Cha, Chull Hee; Park, Jai Soung; Kim, Young Beom; Lee, Hae Kyung; Choi, Deuk Lin; Kim, Kyung Ho; Park, Choon Sik [Soonchunhyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate on the basis of the pulmonary function test the correlation between the extent of air trapping on HRCT with the severity of airway obstruction and also to identify the prognostic effect of the extent of air trapping after treatment of asthma. Thirty five patients with clinically diagnosed bronchial asthma and air trapping, as seen on HRCT, were included in this study. We quantitatively analysed on HRCT the extent of air trapping and then statistically compared this with the clinical parameters of the pulmonary function test. We classified the patients into two groups on the basis of the pulmonary function test and clinical status : Group 1 (N=35), the total number of asthmatic patients; Group 2 (N=18), relatively stable asthmatics without acute asthmatic attack who showed FEV1 of more than 80% of the predicted value. Using the functional paramenters of PEFR, one of the obijective indicators of improvement in airway obstruction, we also classified the patients into three groups on the basis of interval between treatment and clinical improvement. The result of this was as follows : group 1, asymptomatic group (initial PEFR within normal limit, N=7); group 2, early responder (improvement of PEFR within three hospital days, N=18); group 3, late responder (improvement of PEFR within fourteen hospital days should there be a number here). Using HRCT, we then statistically analysed the differences between the three groups in the extent of air trapping. Among the total of 35 asthmatics, the extent of air trapping on HRCT showed significant correlation with FEV1 (r= -0.6161, p < 0.001) and MEFR (r= -0.6012, p < 0.001). Among the relatively stable asthmatics who showed FEV1 more than 80% of the predicted value, MEFR (r= -0.7553, p < 0.001) and FEF75 (r= -0.7529, p=0.012) showed statistically significant correlation with the extent of air trapping on HRCT, but there was no significant correlation between air trapping on HRCT and FEV1. In the three groups of

  11. The Cherenkov correlated timing detector: beam test results from quartz and acrylic bars

    International Nuclear Information System (INIS)

    Kichimi, H.; Sugaya, Y.; Yamaguchi, H.; Yoshimura, Y.; Kanda, S.; Olsen, S.; Ueno, K.; Varner, G.; Bergfeld, T.; Bialek, J.; Lorenc, J.; Palmer, M.; Rudnick, G.; Selen, M.; Auran, T.; Boyer, V.; Honscheid, K.; Tamura, N.; Yoshimura, K.; Lu, C.; Marlow, D.; Mindas, C.; Prebys, E.; Asai, M.; Kimura, A.; Hayashi, S.

    1996-01-01

    Several prototypes of a Cherenkov correlated timing (CCT) detector have been tested at the KEK-PS test beam line. We describe the results for Cherenkov light yields and timing characteristics from quartz and acrylic bar prototypes. A Cherenkov angle resolution is found to be 15 mrad at a propagation distance of 100 cm with a 2 cm thick quartz bar prototype. (orig.)

  12. Reliability of the Timed Up and Go test and Ten-Metre Timed Walk Test in Pregnant Women with Pelvic Girdle Pain.

    Science.gov (United States)

    Evensen, Natalie M; Kvåle, Alice; Braekken, Ingeborg H

    2015-09-01

    There is a lack of functional objective tests available to measure functional status in women with pelvic girdle pain (PGP). The purpose of this study was to establish test-retest and intertester reliability of the Timed Up and Go (TUG) test and Ten-metre Timed Walk Test (10mTWT) in pregnant women with PGP. A convenience sample of women was recruited over a 4-month period and tested on two occasions, 1 week apart to determine test-retest reliability. Intertester reliability was established between two assessors at the first testing session. Subjects were instructed to undertake the TUG and 10mTWT at maximum speed. One practise trial and two timed trials for each walking test was undertaken on Day 1 and one practise trial and one timed trial on Day 2. Seventeen women with PGP aged 31.1 years (SD [standard deviation] = 2.3) and 28.7 weeks pregnant (SD = 7.4) completed gait testing. Test-retest reliability using the intraclass correlation coefficient (ICC) was excellent for the TUG (0.88) and good for the 10mTWT (0.74). Intertester reliability was determined in the first 13 participants with excellent ICC values being found for both walking tests (TUG: 0.95; 10mTWT: 0.94). This study demonstrated that the TUG and 10mTWT undertaken at fast pace are reliable, objective functional tests in pregnant women with PGP. While both tests are suitable for use in the clinical and research settings, we would recommend the TUG given the findings of higher test-retest reliability and as this test requires less space and time to set up and score. Future studies in a larger sample size are warranted to confirm the results of this study. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Spanish validation of the social stigma scale: Community Attitudes towards Mental Illness.

    Science.gov (United States)

    Ochoa, Susana; Martínez-Zambrano, Francisco; Vila-Badia, Regina; Arenas, Oti; Casas-Anguera, Emma; García-Morales, Esther; Villellas, Raúl; Martín, José Ramón; Pérez-Franco, María Belén; Valduciel, Tamara; García-Franco, Mar; Miguel, Jose; Balsera, Joaquim; Pascual, Gemma; Julia, Eugènia; Casellas, Diana; Haro, Josep Maria

    2016-01-01

    The stigma against people with mental illness is very high. In Spain there are currently no tools to assess this construct. The aim of this study was to validate the Spanish version of the Community Attitudes towards Mental Illness questionnaire in an adolescent population, and determining its internal consistency and temporal stability. Another analysis by gender will be also performed. A translation and back-translation of the Community Attitudes towards Mental Illness was performed. A total of 150 students of between 14 and 18 years-old were evaluated with this tool in two stages. Internal consistency was tested using Cronbach α; and intraclass correlation coefficient was used for test-retest reliability. Gender-stratified analyses were also performed. The Cronbach α was 0.861 for the first evaluation and 0.909 for the second evaluation. The values of the intraclass correlation coefficient ranged from 0.775 to 0.339 in the item by item analysis, and between 0.88 and 0.81 in the subscales. In the segmentation by gender, it was found that girls scored between 0.797 and 0.863 in the intraclass correlation coefficient, and boys scored between 0.889 and 0.774. In conclusion, the Community Attitudes towards Mental Illness is a reliable tool for the assessment of social stigma. Although reliable results have been found for boys and girls, our results found some gender differences in the analysis. Copyright © 2014 SEP y SEPB. Published by Elsevier España. All rights reserved.

  14. INTRA-RATER RELIABILITY OF THE MULTIPLE SINGLE-LEG HOP-STABILIZATION TEST AND RELATIONSHIPS WITH AGE, LEG DOMINANCE AND TRAINING.

    Science.gov (United States)

    Sawle, Leanne; Freeman, Jennifer; Marsden, Jonathan

    2017-04-01

    Balance is a complex construct, affected by multiple components such as strength and co-ordination. However, whilst assessing an athlete's dynamic balance is an important part of clinical examination, there is no gold standard measure. The multiple single-leg hop-stabilization test is a functional test which may offer a method of evaluating the dynamic attributes of balance, but it needs to show adequate intra-tester reliability. The purpose of this study was to assess the intra-rater reliability of a dynamic balance test, the multiple single-leg hop-stabilization test on the dominant and non-dominant legs. Intra-rater reliability study. Fifteen active participants were tested twice with a 10-minute break between tests. The outcome measure was the multiple single-leg hop-stabilization test score, based on a clinically assessed numerical scoring system. Results were analysed using an Intraclass Correlations Coefficient (ICC 2,1 ) and Bland-Altman plots. Regression analyses explored relationships between test scores, leg dominance, age and training (an alpha level of p = 0.05 was selected). ICCs for intra-rater reliability were 0.85 for the dominant and non-dominant legs (confidence intervals = 0.62-0.95 and 0.61-0.95 respectively). Bland-Altman plots showed scores within two standard deviations. A significant correlation was observed between the dominant and non-dominant leg on balance scores (R 2 =0.49, ptest demonstrated strong intra-tester reliability with active participants. Younger participants who trained more, have better balance scores. This test may be a useful measure for evaluating the dynamic attributes of balance. 3.

  15. Estudo da validade e confiabilidade intra e interobservador da versão modificada do teste de Schöber modificado em indivíduos com lombalgia Study of validity and intra and inter-observer reliability of modified-modified Schöber test in subjects with low-back pain

    Directory of Open Access Journals (Sweden)

    Christiane de Souza Guerino Macedo

    2009-09-01

    Full Text Available Em pacientes com lombalgia, mensura-se a amplitude de movimento (ADM da coluna lombar por meio da versão modificada do teste de Schöber modificado (MTSM, mas suas propriedades psicométricas não são comprovadas para uso clínico. Este estudo verificou a validade e confiabilidade intra e interobservador do MTSM em indivíduos com lombalgia, comparando as medidas da ADM com as obtidas por meio de radiografia, método considerado padrão-ouro. Participaram 20 voluntários com lombalgia, de ambos os sexos, funcionários de um Hospital Universitário. O MTSM foi aplicado duas vezes por dois avaliadores. As medidas obtidas pelo teste e por radiografia foram comparadas usando o coeficiente de correlação de Pearson, obtendo-se r=0,14, ou seja, correlação fraca. O coeficiente de correlação intraclasse (CCI dos MTSM intra-observador foi 0,96 (IC 95% 0,91;0,98 e interobservador 0,93 (IC 95% 0,84;0,97, indicando alta confiabilidade; o teste de Bland & Altman mostrou alta concordância intra e interobservador, com valores de -0,21 e -0,28, respectivamente. Embora tenha sido encontrada alta confiabilidade intra e interobservador na aplicação da versão modificada do teste de Schöber modificado, este apresentou baixa validade para medir a ADM da coluna lombar, quando comparado ao padrão-ouro.In patients with low-back pain the lumbar spine range of motion (ROM is often measured by the modified version of the modified Schöber test (MMST, but its psychometric properties have not been ascertained for clinical use. The purpose here was to verify intra and inter-observer validity and reliability of the MMST in subjects with low-back pain, and to compare obtained ROM measures to those obtained by radiography, taken as gold standard. The study involved 20 subjects with chronic low-back pain, of both sexes, employees at a university hospital. The MMST was applied twice by two examiners each. The Pearson correlation coefficient found when comparing

  16. Efficacy of the National Football League-225 Test to Track Changes in One Repetition Maximum Bench Press After Training in National Collegiate Athletic Association Division IA Football Players.

    Science.gov (United States)

    Mann, J Bryan; Ivey, Pat A; Stoner, Josh D; Mayhew, Jerry L; Brechue, William F

    2015-11-01

    Numerous investigations have attested to the efficacy of the National Football League (NFL)-225 test to estimate one repetition maximum (1RM) bench press. However, no studies have assessed the efficacy of the test to track changes in strength across a training program. The purpose of this study was to determine the accuracy of the NFL-225 test for determining the change in 1RM bench press in National Collegiate Athletic Association Division IA college football players after training. Over a 4-year period, players (n = 203) were assessed before and after a 6-week off-season resistance program for 1RM bench press and repetitions completed with 102.3 kg (225 lbs). Test sessions typically occurred within 1 week of each other. Players significantly increased 1RM by 4.2 ± 8.6 kg and NFL-225 repetitions by 0.9 ± 2.3, although the effect size (ES) for each was trivial (ES = 0.03 and 0.07, respectively). National Football League 225 prediction equations had higher correlations with 1RM before training (intraclass correlation coefficient [ICC] = 0.95) than after training (ICC = 0.75). The correlation between the change in NFL-225 repetitions and change in 1RM was low and negative (r = -0.22, p bench press strength after short-term training.

  17. Validation and reliability of the Baecke questionnaire for the evaluation of habitual physical activity in adult men

    Directory of Open Access Journals (Sweden)

    Alex Antonio Florindo

    2003-06-01

    Full Text Available The aim of this study was to verify validity and reliability of the scores for physical exercise in leisure (PEL, leisure and locomotion activities (LLA, and total score (TS of the Baecke habitual physical activity questionnaire in adult males. Twenty-one students of Physical Education were evaluated. For validation, the maximum oxygen uptake (O2max and the decrease of the heart rate in percentile (%DHR were measured through the Cooper's 12-minute walk or run test, and an annual index of physical exercise (IPE, and a week index of locomotion activities (ILA. The reliability was verified through test-retest with interval of 45 days. The Pearson correlation coefficient, and partial correlation adjusted for age and body mass index were used for validation. The intraclass correlation and paired t-test were used for reliability. The results indicated that %DHR was correlated with LLA and TS (r = 0.47 and p = 0.030; r = 0.48 and p = 0.027, respectively. IPE was correlated with PEL and TS (r = 0.56 and p = 0.008; r = 0.46 and p = 0.036, respectively. ILA was correlated with LLA and TS (r = 0.64 and p = 0.002 and r = 0.51 and p = 0.017, respectively. There was no significant difference in PEL, LLA and TS means in test-retest. The intraclass correlations were r = 0.69; r = 0.80 and r = 0.77, respectively for PEL, LLA and TS. In conclusion, the Baecke questionnaire is valid and reliable to measure habitual physical activity in Brazilian adult men.

  18. A test of multiple correlation temporal window characteristic of non-Markov processes

    Science.gov (United States)

    Arecchi, F. T.; Farini, A.; Megna, N.

    2016-03-01

    We introduce a sensitive test of memory effects in successive events. The test consists of a combination K of binary correlations at successive times. K decays monotonically from K = 1 for uncorrelated events as a Markov process. For a monotonic memory fading, K1 temporal window in cognitive tasks consisting of the visual identification of the front face of the Necker cube after a previous presentation of the same. We speculate that memory effects provide a temporal window with K>1 and this experiment could be a possible first step towards a better comprehension of this phenomenon. The K>1 behaviour is maximal at an inter-measurement time τ around 2s with inter-subject differences. The K>1 persists over a time window of 1s around τ; outside this window the K1 window in pairs of successive perceptions suggests that, at variance with single visual stimuli eliciting a suitable response, a pair of stimuli shortly separated in time displays mutual correlations.

  19. Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

    Science.gov (United States)

    Julsvoll, Elisabeth Heggem; Vøllestad, Nina Køpke; Opseth, Gro; Robinson, Hilde Stendal

    2017-09-01

    Clinical tests used to examine patients with temporomandibular disorders vary in methodological quality, and some are not tested for reliability. The purpose of this cross-sectional study was to evaluate inter-tester reliability of clinical tests and a cluster of tests used to examine patients with long-lasting temporomandibular disorders. Forty patients with pain in the temporomandibular area treated by health-professionals were included. They were between 18-70 years, had 65 symptomatic (33 right/32 left) and 15 asymptomatic joints. Two manual therapists examined all participants with selected tests. Percentage agreement and the kappa coefficient ( k ) with 95% confidence interval (CI) were used to evaluate the tests with categorical outcomes. For tests with continuous outcomes, the relative inter-tester reliability was assessed by the intraclass-correlation-coefficient (ICC 3,1 , 95% CI) and the absolute reliability was calculated by the smallest detectable change (SDC). The best reliability among single tests was found for the dental stick test, the joint-sound test ( k  = 0.80-1.0) and range of mouth-opening (ICC 3,1 (95% CI) = 0.97 (0.95-0.98) and SDC = 4 mm). The reliability of cluster of tests was excellent with both four and five positive tests out of seven. The reliability was good to excellent for the clinical tests and the cluster of tests when performed by experienced therapists. The tests are feasible for use in the clinical setting. They require no advanced equipment and are easy to perform.

  20. Reliability, validity, and minimal detectable change of the push-off test scores in assessing upper extremity weight-bearing ability.

    Science.gov (United States)

    Mehta, Saurabh P; George, Hannah R; Goering, Christian A; Shafer, Danielle R; Koester, Alan; Novotny, Steven

    2017-11-01

    Clinical measurement study. The push-off test (POT) was recently conceived and found to be reliable and valid for assessing weight bearing through injured wrist or elbow. However, further research with larger sample can lend credence to the preliminary findings supporting the use of the POT. This study examined the interrater reliability, construct validity, and measurement error for the POT in patients with wrist conditions. Participants with musculoskeletal (MSK) wrist conditions were recruited. The performance on the POT, grip isometric strength of wrist extensors was assessed. The shortened version of the Disabilities of the Arm, Shoulder and Hand and numeric pain rating scale were completed. The intraclass correlation coefficient assessed interrater reliability of the POT. Pearson correlation coefficients (r) examined the concurrent relationships between the POT and other measures. The standard error of measurement and the minimal detectable change at 90% confidence interval were assessed as measurement error and index of true change for the POT. A total of 50 participants with different elbow or wrist conditions (age: 48.1 ± 16.6 years) were included in this study. The results of this study strongly supported the interrater reliability (intraclass correlation coefficient: 0.96 and 0.93 for the affected and unaffected sides, respectively) of the POT in patients with wrist MSK conditions. The POT showed convergent relationships with the grip strength on the injured side (r = 0.89) and the wrist extensor strength (r = 0.7). The POT showed smaller standard error of measurement (1.9 kg). The minimal detectable change at 90% confidence interval for the POT was 4.4 kg for the sample. This study provides additional evidence to support the reliability and validity of the POT. This is the first study that provides the values for the measurement error and true change on the POT scores in patients with wrist MSK conditions. Further research should examine the

  1. The Validity and Reliability Test of the Indonesian Version of Gastroesophageal Reflux Disease Quality of Life (GERD-QOL) Questionnaire.

    Science.gov (United States)

    Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti

    2017-01-01

    to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; pGERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.

  2. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Microstructural evolution in the HAZ of Inconel 718 and correlation with the hot ductility test

    Science.gov (United States)

    Thompson, R. G.; Genculu, S.

    1983-01-01

    The nickel-base alloy 718 was evaluated to study the role of preweld heat treatment in reducing or eliminating heat-affected zone hot cracking. Three heat treatments were studied using the Gleeble hot ductility test. A modified hot ductility test was also used to follow the evolution of microstructure during simulated welding thermal cycles. The microstructural evolution was correlated with the hot ductility data in order to evaluate the mechanism of hot cracking in alloy 718. The correlation of hot ductility with microstructure showed that recrystallization, grain growth, and dissolution of precipitates did not in themselves cause any loss of ductility during cooling. Ductility loss during cooling was not initiated until the constitutional liquation of NbC particles was observed in the microstructure. Laves-type phases were found precipitated in the solidified grain boundaries but were not found to correlate with any ductility loss parameter. Mechanisms are reviewed which help to explain how heat treatment controls the hot crack susceptibility of alloy 718 as measured in the hot ductility test.

  4. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    International Nuclear Information System (INIS)

    Peng, Steven Shinn-Forng; Jeng, Yung-Ming; Hsu, Wen-Ming; Ho, Ming-Chih; Yang, Justin Cheng-Ta

    2015-01-01

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm 2 in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R 2 = 0.398, p = 0.024 and R 2 = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  5. Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Steven Shinn-Forng [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); Jeng, Yung-Ming [National Taiwan University, Department of Pathology, Medical College and Hospital, Taipei (China); Hsu, Wen-Ming; Ho, Ming-Chih [National Taiwan University, Department of Surgery, Medical College and Hospital, Taipei, Taiwan (China); Yang, Justin Cheng-Ta [National Taiwan University, Department of Medical Imaging, Medical College and Hospital, Taipei (China); National Taiwan University, Institute of Biomedical Engineering, College of Engineering and College of Medicine, Taipei (China)

    2015-10-15

    Hepatic apparent diffusion coefficient (ADC) values and ADC-related indices were correlated with the Mayo risk score for primary biliary cirrhosis (MRSPBC) and METAVIR scores of liver specimens to determine the clinical and pathological significance of diffusion-weighted magnetic resonance imaging (DWMRI). Thirty-two patients with biliary atresia (BA; mean age 461 days, range 11-4616 days) received magnetic resonance examinations from March 2009 to August 2013. A free-breathing DWMRI sequence was performed with the single-shot echo-planar imaging technique with b = 0 and 500 s/mm{sup 2} in all 32 BA patients and 24 controls. We used the ordinal logistic regression test and Spearman rank correlation test to analyse the relationships between the MRSPBC and METAVIR fibrosis scores and right liver-to-psoas ADC ratios (LTPARs). BA patients had significantly lower LTPARs in both hepatic lobes than controls (p < 0.01). Right LTPARs, showing moderate intraobserver agreement (intraclass correlation coefficient = 0.736) and interobserver reliability (intraclass correlation coefficient = 0.659), were negatively correlated with MRSPBC and METAVIR fibrosis scores (R{sup 2} = 0.398, p = 0.024 and R{sup 2} = 0.628, p < 0.001, respectively). Right LTPARs may be used for long-term follow-up of cirrhosis severity in BA patients. (orig.)

  6. Measuring and testing dependence by correlation of distances

    OpenAIRE

    Székely, Gábor J.; Rizzo, Maria L.; Bakirov, Nail K.

    2007-01-01

    Distance correlation is a new measure of dependence between random vectors. Distance covariance and distance correlation are analogous to product-moment covariance and correlation, but unlike the classical definition of correlation, distance correlation is zero only if the random vectors are independent. The empirical distance dependence measures are based on certain Euclidean distances between sample elements rather than sample moments, yet have a compact representation analogous to the clas...

  7. Test-Retest Reliability and Minimal Detectable Change of the D2 Test of Attention in Patients with Schizophrenia.

    Science.gov (United States)

    Lee, Posen; Lu, Wen-Shian; Liu, Chin-Hsuan; Lin, Hung-Yu; Hsieh, Ching-Lin

    2017-12-08

    The d2 Test of Attention (D2) is a commonly used measure of selective attention for patients with schizophrenia. However, its test-retest reliability and minimal detectable change (MDC) are unknown in patients with schizophrenia, limiting its utility in both clinical and research settings. The aim of the present study was to examine the test-retest reliability and MDC of the D2 in patients with schizophrenia. A rater administered the D2 on 108 patients with schizophrenia twice at a 1-month interval. Test-retest reliability was determined through the calculation of the intra-class correlation coefficient (ICC). We also carried out Bland-Altman analysis, which included a scatter plot of the differences between test and retest against their mean. Systematic biases were evaluated by use of a paired t-test. The ICCs for the D2 ranged from 0.78 to 0.94. The MDCs (MDC%) of the seven subscores were 102.3 (29.7), 19.4 (85.0), 7.2 (94.6), 21.0 (69.0), 104.0 (33.1), 105.0 (35.8), and 7.8 (47.8), which represented limited-to-acceptable random measurement error. Trends in the Bland-Altman plots of the omissions (E1), commissions (E2), and errors (E) were noted, presenting that the data had heteroscedasticity. According to the results, the D2 had good test-retest reliability, especially in the scores of TN, TN-E, and CP. For the further research, finding a way to improve the administration procedure to reduce random measurement error would be important for the E1, E2, E, and FR subscores. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Cross-cultural adaptation and validation of the sino-nasal outcome test (SNOT-22) for Spanish-speaking patients.

    Science.gov (United States)

    de los Santos, Gonzalo; Reyes, Pablo; del Castillo, Raúl; Fragola, Claudio; Royuela, Ana

    2015-11-01

    Our objective was to perform translation, cross-cultural adaptation and validation of the sino-nasal outcome test 22 (SNOT-22) to Spanish language. SNOT-22 was translated, back translated, and a pretest trial was performed. The study included 119 individuals divided into 60 cases, who met diagnostic criteria for chronic rhinosinusitis according to the European Position Paper on Rhinosinusitis 2012; and 59 controls, who reported no sino-nasal disease. Internal consistency was evaluated with Cronbach's alpha test, reproducibility with Kappa coefficient, reliability with intraclass correlation coefficient (ICC), validity with Mann-Whitney U test and responsiveness with Wilcoxon test. In cases, Cronbach's alpha was 0.91 both before and after treatment, as for controls, it was 0.90 at their first test assessment and 0.88 at 3 weeks. Kappa coefficient was calculated for each item, with an average score of 0.69. ICC was also performed for each item, with a score of 0.87 in the overall score and an average among all items of 0.71. Median score for cases was 47, and 2 for controls, finding the difference to be highly significant (Mann-Whitney U test, p internal consistency, reliability, reproducibility, validity and responsiveness necessary to be a valid instrument to be used in clinical practice.

  9. Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

    International Nuclear Information System (INIS)

    McCuller, Lee Patrick

    2015-01-01

    The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of 7·10 -21 m/√Hz with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of 2.5·10 -18 m/√Hz, but their correlation with a time-bandwidth product of 4·10 11 digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

  10. Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

    Energy Technology Data Exchange (ETDEWEB)

    McCuller, Lee Patrick [Univ. of Chicago, IL (United States)

    2015-12-01

    The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\\times10^{−21}$ m/$\\sqrt{\\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\\times 10^{−18}$ m/$\\sqrt{\\rm Hz}$, but their correlation with a time-bandwidth product of $4\\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

  11. Experimental test of Bell's inequalities using angular correlation of compton-scattered annihilation photons

    International Nuclear Information System (INIS)

    Osuch, S.; Popkiewicz, M.; Szeflinski, Z.; Wilhelmi, Z.

    1995-01-01

    The Bell's inequality has been experimentally tested using angular correlation of Compton-scattered photons from annihilation of positrons emitted from 22 Na source. The result shows a better agreement with the quantum mechanics predictions rather than with the Bell's inequality

  12. Reliability and fall experience discrimination of Cross Step Moving on Four Spots Test in the elderly.

    Science.gov (United States)

    Yamaji, Shunsuke; Demura, Shinichi

    2013-07-01

    To examine the reliability and fall experience discrimination of the Cross Step Moving on Four Spots Test (CSFT) and the relationship between CSFT and fall-related physical function. The reliability of the CSFT was examined in a test-retest format with the same tester. Fall history, fall risk, fear of falling, activities of daily living (ADL), and various physical parameters were measured for all participants. A community center and university medical school. Elderly community-dwelling subjects (N=533; 62 men, 471 women) aged 65 to 94 years living independently. Not applicable. Time to complete all the CSFT steps required, fall risk score, ADL score, and fall-related physical function (isometric muscle strength: toe grip, plantar flexion, knee extension, hip flexion, hand grip; balance: 1-leg standing time with eyes open, functional reach test using an elastic stick; and gait: 10-m maximal walking speed). The trial-to-trial reliability test indicated good reliability of the CSFT in both sexes (intraclass correlation coefficient =.833 in men, .825 in women). However, trial-to-trial errors increased with an increase in the CSFT values in both sexes. Significant correlations were observed between the CSFT values and scores for most fall-related physical function tests in both sexes. However, the correlation coefficient for all significant correlations was fall experience) revealed that the fall experience is a significant factor affecting CSFT values; values in fallers were significantly lower than those in nonfallers. The odds ratios in logistic regression analysis were significant in both sexes (men, 1.35; women, 1.48). As determined by the Youden index, the optimal cutoff value for identifying fall experience was 7.32 seconds, with an area under the curve of .676. The CSFT can detect fall experience and is useful in the evaluation of different fall-related physical functions including muscle strength, balance, and mobility. Copyright © 2013 American Congress of

  13. Correlations between the scores of computerized adaptive testing, paper and pencil tests, and the Korean Medical Licensing Examination

    Directory of Open Access Journals (Sweden)

    Mee Young Kim

    2005-06-01

    Full Text Available To evaluate the usefulness of computerized adaptive testing (CAT in medical school, the General Examination for senior medical students was administered as a paper and pencil test (P&P and using CAT. The General Examination is a graduate examination, which is also a preliminary examination for the Korean Medical Licensing Examination (KMLE. The correlations between the results of the CAT and P&P and KMLE were analyzed. The correlation between the CAT and P&P was 0.8013 (p=0.000; that between the CAT and P&P was 0.7861 (p=0.000; and that between the CAT and KMLE was 0.6436 (p=0.000. Six out of 12 students with an ability estimate below 0.52 failed the KMLE. The results showed that CAT could replace P&P in medical school. The ability of CAT to predict whether students would pass the KMLE was 0.5 when the criterion of the theta value was set at -0.52 that was chosen arbitrarily for the prediction of pass or failure.

  14. Translation and cultural adaptation of the Manchester-Oxford Foot Questionnaire (MOXFQ) into Persian language.

    Science.gov (United States)

    Mousavian, Alireza; Ebrahimzadeh, Mohammad H; Birjandinejad, Ali; Omidi-Kashani, Farzad; Kachooei, Amir Reza

    2015-12-01

    In this study, we aimed to translate and test the validity and reliablity of the Persian version of the Manchester-Oxford Foot Questionnaire in foot and ankle patients. We translated the Manchester-Oxford Foot Questionnaire to Persian language according to the accepted guidelines, then assessed the psychometric properties including the validity and reliability on 308 patients with long-standing foot and ankle problems. To test the reliability, we calculated the intra-class correlation coefficient (ICC) for test-retest reliability and measured Cronbach's alpha to test the internal consistency. To test the construct validity of the Manchester-Oxford Foot Questionnaire we also administered the Short-Form 36 to patients. Construct validity was supported by significant correlation with SF36 subscales except for pain subscale of the persian MOXFQ with mental health of the SF36 (r=0.207). Intraclass correlation coefficient was 0.79 for the total MOXFQ and ranged from 0.83 to 0.89 for the three subscales. Cronbach's alpha for pain, walking/standing, and social interaction was 0.86, 0.88, and 0.89, respectively, and was 0.79 for the total MOXFQ showing good internal consistency in each domain. The Persian Manchester-Oxford Foot Questionnaire health scoring system is a valid and reliable patient-reported instrument for foot and ankle problems. Copyright © 2015. Published by Elsevier Ltd.

  15. Construct validity, test-retest reliability and internal consistency of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) in patients with carpal tunnel syndrome.

    Science.gov (United States)

    Buntragulpoontawee, Montana; Phutrit, Suphatha; Tongprasert, Siam; Wongpakaran, Tinakon; Khunachiva, Jeeranan

    2018-03-27

    This study evaluated additional psychometric properties of the Thai version of the disabilities of the arm, shoulder and hand questionnaire (DASH-TH) which included, test-retest reliability, construct validity, internal consistency of in patients with carpal tunnel syndrome. As for determining construct validity, the Thai EuroQOL questionnaire (EQ-5D-5L) was also administered in order to examine convergent and divergent validity. Fifty patients completed both questionnaires. The DASH-TH showed excellent test-retest reliability (intraclass correlation coefficient = 0.811) and internal consistency (Cronbach's alpha = 0.911). The exploratory factor analysis yielded a six-factor solution while the confirmatory factor analysis denoted that the hypothesized model adequately fit the data with a comparative fit index of 0.967 and a Tucker-Lewis index of 0.964. The related subscales between the DASH-TH and the Thai EQ-5D-5L were significantly correlated, indicating the DASH-TH's convergent and discriminant validity. The DASH-TH demonstrated good reliability, internal consistency construct validity, and multidimensionality, in assessing the upper extremity function in carpal tunnel syndrome patients.

  16. Patient-reported speech in noise difficulties and hyperacusis symptoms and correlation with test results.

    Science.gov (United States)

    Spyridakou, Chrysa; Luxon, Linda M; Bamiou, Doris E

    2012-07-01

    To compare self-reported symptoms of difficulty hearing speech in noise and hyperacusis in adults with auditory processing disorders (APDs) and normal controls; and to compare self-reported symptoms to objective test results (speech in babble test, transient evoked otoacoustic emission [TEOAE] suppression test using contralateral noise). A prospective case-control pilot study. Twenty-two participants were recruited in the study: 10 patients with reported hearing difficulty, normal audiometry, and a clinical diagnosis of APD; and 12 normal age-matched controls with no reported hearing difficulty. All participants completed the validated Amsterdam Inventory for Auditory Disability questionnaire, a hyperacusis questionnaire, a speech in babble test, and a TEOAE suppression test using contralateral noise. Patients had significantly worse scores than controls in all domains of the Amsterdam Inventory questionnaire (with the exception of sound detection) and the hyperacusis questionnaire (P reported symptoms of difficulty hearing speech in noise and speech in babble test results in the right ear (ρ = 0.624, P = .002), and between self-reported symptoms of hyperacusis and TEOAE suppression test results in the right ear (ρ = -0.597 P = .003). There was no significant correlation between the two tests. A strong correlation was observed between right ear speech in babble and patient-reported intelligibility of speech in noise, and right ear TEOAE suppression by contralateral noise and hyperacusis questionnaire. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  17. The Category Cued Recall test in very mild Alzheimer's disease: discriminative validity and correlation with semantic memory functions.

    Science.gov (United States)

    Vogel, A; Mortensen, E L; Gade, A; Waldemar, G

    2007-01-01

    Episodic memory tests that measure cued recall may be particularly effective in the diagnosis of early Alzheimer's disease (AD) because they examine both episodic and semantic memory functions. The Category Cued Recall (CCR) test provides superordinate semantic cues at encoding and retrieval, and high discriminative validity has been claimed for this test. The aim of this study was to investigate the discriminative validity for this test when compared with the 10-word memory list from Alzheimer's Disease Assessment Scale (ADAS-cog) that measures free recall. The clinical diagnosis of AD was taken as the standard. It was also investigated whether the two episodic memory tests correlated with measures of semantic memory. The tests were administered to 35 patients with very mild AD (Mini Mental State Examination score >22) and 28 control subjects. Both tests had high sensitivity (>88%) with high specificity (>89%). One out of the five semantic memory tests was significantly correlated to performances on CCR, whereas delayed recall on the ADAS-cog memory test was significantly correlated to two semantic tests. In conclusion, the discriminative validity of the CCR test and the ADAS-cog memory test was equivalent in very mild AD. This may be because CCR did not tap more semantic processes, which are impaired in the earliest phases of AD, than a test of free recall.

  18. Adaptation, test-retest reliability, and construct validity of the Physical Activity Neighborhood Environment Scale in Nigeria (PANES-N).

    Science.gov (United States)

    Oyeyemi, Adewale L; Sallis, James F; Oyeyemi, Adetoyeje Y; Amin, Mariam M; De Bourdeaudhuij, Ilse; Deforche, Benedicte

    2013-11-01

    This study adapted the Physical Activity Neighborhood Environment Scale (PANES) to the Nigerian context and assessed the test-retest reliability and construct validity of the Nigerian version (PANESN). A multidisciplinary panel of experts adapted the original PANES to reflect the built and social environment of Nigeria. The adapted PANES was subjected to cognitive testing and test retest reliability in a diverse sample of Nigerian adults (N = 132) from different neighborhood types. Intraclass Correlation Coefficients (ICC) was used to assess test-retest reliability, and construct validity was investigated with Analysis of Covariance for differences in environmental attributes between neighborhoods. Four of the 17 items on the original PANES were significantly modified, 3 were removed and 2 new items were incorporated into the final version of adapted PANES-N. Test-retest reliability was substantial to almost perfect (ICC = 0.62-1.00) for all items on the PANES-N, and residents of neighborhoods in the inner city reported higher residential density, land use mix and safety, but lower pedestrian facilities and aesthetics than did residents of government reserved area/new layout neighborhoods. The PANES-N appears promising for assessing environmental perceptions related to physical activity in Nigeria, but further testing is required to assess its applicability across Africa.

  19. Repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography macular metrics in healthy subjects.

    Science.gov (United States)

    Fang, Danqi; Tang, Fang Yao; Huang, Haifan; Cheung, Carol Y; Chen, Haoyu

    2018-05-29

    To investigate the repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography (SS-OCTA) metrics in healthy subjects. Thirty-three healthy normal subjects were enrolled. The macula was scanned four times by an SS-OCTA system using the 3 mm×3 mm mode. The superficial capillary map images were analysed using a MATLAB program. A series of parameters were measured: foveal avascular zone (FAZ) area, FAZ perimeter, FAZ circularity, parafoveal vessel density, fractal dimension and vessel diameter index (VDI). The repeatability of four scans was determined by intraclass correlation coefficient (ICC). Then the averaged results were analysed for intereye difference, correlation and agreement using paired t-test, Pearson's correlation coefficient (r), ICC and Bland-Altman plot. The repeatability assessment of the macular metrics exported high ICC values (ranged from 0.853 to 0.996). There is no statistically significant difference in the OCTA metrics between the two eyes. FAZ area (ICC=0.961, r=0.929) and FAZ perimeter (ICC=0.884, r=0.802) showed excellent binocular correlation. Fractal dimension (ICC=0.732, r=0.578) and VDI (ICC=0.707, r=0.547) showed moderate binocular correlation, while parafoveal vessel density had poor binocular correlation. Bland-Altman plots showed the range of agreement was from -0.0763 to 0.0954 mm 2 for FAZ area and from -0.0491 to 0.1136 for parafoveal vessel density. The macular metrics obtained using SS-OCTA showed excellent repeatability in healthy subjects. We showed high intereye correlation in FAZ area and perimeter, moderate correlation in fractal dimension and VDI, while vessel density had poor correlation in normal healthy subjects. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Test-Retest Reliability of Measurements of Hand-Grip Strength Obtained by Dynamometry from Older Adults: A Systematic Review of Research in the PubMed Database.

    Science.gov (United States)

    Bohannon, R W

    2017-01-01

    A systematic review was performed to summarize literature describing the test-retest reliability of grip strength measures obtained from older adults. Relevant literature was identified via a PubMed search. Seventeen articles were deemed appropriate based on inclusion and exclusion criteria. The relative test-retest reliability of grip strength measures obtained by dynamometry was good to excellent (intra-class correlation coefficients > 0.80) in all but 3 studies, which involved older adults with severe dementia. Absolute reliability, as indicated by summary statistics such as the minimum detectable change (95%), was more variable. As a percentage, that change ranged from 14.5% to 98.5%. Consequently, clinicians can be confident in the relative reliability of grip strength measures obtained from at risk older adults. However, relatively large percentage changes in grip strength may be necessary to conclude with confidence that a real change has occurred over time in some populations.

  1. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  2. Tests for the Assessment of Sport-Specific Performance in Olympic Combat Sports: A Systematic Review With Practical Recommendations.

    Science.gov (United States)

    Chaabene, Helmi; Negra, Yassine; Bouguezzi, Raja; Capranica, Laura; Franchini, Emerson; Prieske, Olaf; Hbacha, Hamdi; Granacher, Urs

    2018-01-01

    The regular monitoring of physical fitness and sport-specific performance is important in elite sports to increase the likelihood of success in competition. This study aimed to systematically review and to critically appraise the methodological quality, validation data, and feasibility of the sport-specific performance assessment in Olympic combat sports like amateur boxing, fencing, judo, karate, taekwondo, and wrestling. A systematic search was conducted in the electronic databases PubMed, Google-Scholar, and Science-Direct up to October 2017. Studies in combat sports were included that reported validation data (e.g., reliability, validity, sensitivity) of sport-specific tests. Overall, 39 studies were eligible for inclusion in this review. The majority of studies (74%) contained sample sizes sport-specific tests (intraclass correlation coefficient [ICC] = 0.43-1.00). Content validity was addressed in all included studies, criterion validity (only the concurrent aspect of it) in approximately half of the studies with correlation coefficients ranging from r = -0.41 to 0.90. Construct validity was reported in 31% of the included studies and predictive validity in only one. Test sensitivity was addressed in 13% of the included studies. The majority of studies (64%) ignored and/or provided incomplete information on test feasibility and methodological limitations of the sport-specific test. In 28% of the included studies, insufficient information or a complete lack of information was provided in the respective field of the test application. Several methodological gaps exist in studies that used sport-specific performance tests in Olympic combat sports. Additional research should adopt more rigorous validation procedures in the application and description of sport-specific performance tests in Olympic combat sports.

  3. Tuboimpedance: A New Test of Eustachian Tube Function.

    Science.gov (United States)

    Smith, Matthew E; Zou, Charlie C; Blythe, Andrew J C; Tysome, James R

    2017-04-01

    Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

  4. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    Science.gov (United States)

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  5. Correlation of finite element free vibration predictions using random vibration test data. M.S. Thesis - Cleveland State Univ.

    Science.gov (United States)

    Chambers, Jeffrey A.

    1994-01-01

    Finite element analysis is regularly used during the engineering cycle of mechanical systems to predict the response to static, thermal, and dynamic loads. The finite element model (FEM) used to represent the system is often correlated with physical test results to determine the validity of analytical results provided. Results from dynamic testing provide one means for performing this correlation. One of the most common methods of measuring accuracy is by classical modal testing, whereby vibratory mode shapes are compared to mode shapes provided by finite element analysis. The degree of correlation between the test and analytical mode shapes can be shown mathematically using the cross orthogonality check. A great deal of time and effort can be exhausted in generating the set of test acquired mode shapes needed for the cross orthogonality check. In most situations response data from vibration tests are digitally processed to generate the mode shapes from a combination of modal parameters, forcing functions, and recorded response data. An alternate method is proposed in which the same correlation of analytical and test acquired mode shapes can be achieved without conducting the modal survey. Instead a procedure is detailed in which a minimum of test information, specifically the acceleration response data from a random vibration test, is used to generate a set of equivalent local accelerations to be applied to the reduced analytical model at discrete points corresponding to the test measurement locations. The static solution of the analytical model then produces a set of deformations that once normalized can be used to represent the test acquired mode shapes in the cross orthogonality relation. The method proposed has been shown to provide accurate results for both a simple analytical model as well as a complex space flight structure.

  6. Oblique penetration modeling and correlation with field tests into a soil target

    Energy Technology Data Exchange (ETDEWEB)

    Longcope, D.B. Jr. [Sandia National Labs., Albuquerque, NM (United States). Structural Dynamics Dept.

    1996-09-01

    An oblique penetration modeling procedure is evaluated by correlation with onboard acceleration data from a series of six penetration tests into Antelope Dry Lake soil at Tonopah Test Range, Nevada. The modeling represents both the loading which is coupled to the penetrator bending and the penetrator structure including connections between the major subsections. Model results show reasonable agreement with the data which validates the modeling procedure within a modest uncertainty related to accelerometer clipping and rattling of the telemetry package. The experimental and analytical results provide design guidance for the location and lateral restraint of components to reduce their shock environment.

  7. Neighborhood walkability scale (News - Brazil: Back translation and Reliability

    Directory of Open Access Journals (Sweden)

    Jorge Both

    2007-12-01

    Full Text Available Existem, no Brasil, poucos instrumentos para avaliar a relação entre o ambiente físico e a prática de atividades físicas. O objetivo do estudo foi analisar a tradução, a retradução e a reprodutibilidade do questionário NEWS (Neighborhood Environment Walkability Scale para o português do Brasil. Os procedimentos metodológicos foram estruturados em duas etapas. Primeiramente, efetuou-se a tradução e a retradução do NEWS com o intuito de verificar a linguagem do instrumento. Em seguida, realizou-se a reprodutibilidade do questionário por meio de teste e re-teste. A amostra desta pesquisa teve a participação de 75 pessoas (45 mulheres e 30 homens, com média de 33 ± 15 anos. A correlação intraclasse, a fidedignidade para as dimensões, o teste de correlação de Spearman e a correlação intraclasse para os indicadores de cada dimensão deste instrumento foram analisados com o auxílio do pacote estatístico SPSS (versão 11.0. O nível de significância adotado foi de p ABSTRACT In Brazil, there are few validated scales that establish the relationship between environmental barriers and physical activity. Therefore, the aim of this study was to analyze the translation, back translation and reliability of the Neighborhood Environment Walkability Scale (NEWS into Brazilian Portuguese. The methodological procedures were structured in two phases. The first phase was to translate and back translate NEWS to verify the instrument language. The second phase was he test and re-test reliability of the questionnaire. The sample was composed of 75 people (45 women and 30 men, mean age of 33 ± 15 years. The statistical analyses to verify the Brazilian NEWS were performed with the SPSS program (version 11.0 for intra-class correlation and reliability for the dimensions; Spearman correlation test and intra-class correlation for all indicators from this questionnaire. The significance level adopted in this survey was p<0.05. The results in

  8. Full-scale locomotive dynamic crash testing and correlations : locomotive consist colliding with steel coil truck at grade crossing (test 3).

    Science.gov (United States)

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision between a locomotive and a highway truck loaded with two heavy steel coils. The locomotive consist was moving at 58 miles per hour before it struc...

  9. CT Perfusion evaluation of gastric cancer. Correlation with histologic type

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Ho; Joo, Ijin [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Kim, Se Hyung [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Han, Joon Koo [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2018-02-15

    To prospectively evaluate if the perfusion parameters of gastric cancer can provide information on histologic subtypes of gastric cancer. We performed preoperative perfusion CT (PCT) and curative gastrectomy in 46 patients. PCT data were analysed using a dedicated software program. Perfusion parameters were obtained by two independent radiologists and were compared according to histologic type using Kruskal-Wallis, Mann-Whitney U test and receiver operating characteristic analysis. To assess inter-reader agreement, we used intraclass correlation coefficient (ICC). Inter-reader agreement for perfusion parameters was moderate to substantial (ICC = 0.585-0.678). Permeability surface value of poorly cohesive carcinoma (PCC) was significantly higher than other histologic types (47.3 ml/100 g/min in PCC vs 26.5 ml/100 g/min in non-PCC, P < 0.001). Mean transit time (MTT) of PCC was also significantly longer than non-PCC (13.0 s in PCC vs 10.3 s in non-PCC, P = 0.032). The area under the curve to predict PCC was 0.891 (P < 0.001) for permeability surface and 0.697 (P = 0.015) for MTT. Obtaining perfusion parameters from PCT was feasible in gastric cancer patients and can aid in the preoperative imaging diagnosis of PCC-type gastric cancer as the permeability surface and MTT value of PCC type gastric cancer were significantly higher than those of non-PCC. (orig.)

  10. CT Perfusion evaluation of gastric cancer. Correlation with histologic type

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Joo, Ijin; Kim, Se Hyung; Han, Joon Koo

    2018-01-01

    To prospectively evaluate if the perfusion parameters of gastric cancer can provide information on histologic subtypes of gastric cancer. We performed preoperative perfusion CT (PCT) and curative gastrectomy in 46 patients. PCT data were analysed using a dedicated software program. Perfusion parameters were obtained by two independent radiologists and were compared according to histologic type using Kruskal-Wallis, Mann-Whitney U test and receiver operating characteristic analysis. To assess inter-reader agreement, we used intraclass correlation coefficient (ICC). Inter-reader agreement for perfusion parameters was moderate to substantial (ICC = 0.585-0.678). Permeability surface value of poorly cohesive carcinoma (PCC) was significantly higher than other histologic types (47.3 ml/100 g/min in PCC vs 26.5 ml/100 g/min in non-PCC, P < 0.001). Mean transit time (MTT) of PCC was also significantly longer than non-PCC (13.0 s in PCC vs 10.3 s in non-PCC, P = 0.032). The area under the curve to predict PCC was 0.891 (P < 0.001) for permeability surface and 0.697 (P = 0.015) for MTT. Obtaining perfusion parameters from PCT was feasible in gastric cancer patients and can aid in the preoperative imaging diagnosis of PCC-type gastric cancer as the permeability surface and MTT value of PCC type gastric cancer were significantly higher than those of non-PCC. (orig.)

  11. Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease.

    Science.gov (United States)

    Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth

    2015-03-01

    To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

  12. Stability of person ability measures in people with acquired brain injury in the use of everyday technology: the test-retest reliability of the Management of Everyday Technology Assessment (META).

    Science.gov (United States)

    Malinowsky, Camilla; Kassberg, Ann-Charlotte; Larsson-Lund, Maria; Kottorp, Anders

    2016-01-01

    To evaluate the test-retest reliability of the Management of Everyday Technology Assessment (META) in a sample of people with acquired brain injury (ABI). The META was administered twice within a two-week period to 25 people with ABI. A Rasch measurement model was used to convert the META ordinal raw scores into equal-interval linear measures of each participant's ability to manage everyday technology (ET). Test-retest reliability of the stability of the person ability measures in the META was examined by a standardized difference Z-test and an intra-class correlations analysis (ICC 1). The results showed that the paired person ability measures generated from the META were stable over the test-retest period for 22 of the 25 subjects. The ICC 1 correlation was 0.63, which indicates good overall reliability. The META demonstrated acceptable test-retest reliability in a sample of people with ABI. The results illustrate the importance of using sufficiently challenging ETs (relative to a person's abilities) to generate stable META measurements over time. Implications for Rehabilitation The findings add evidence regarding the test-retest reliability of the person ability measures generated from the observation assessment META in a sample of people with ABI. The META might support professionals in the evaluation of interventions that are designed to improve clients' performance of activities including the ability to manage ET.

  13. Analysis of the existing correlations of effective friction angle for eastern piedmont soils of Bogota from in situ tests

    Directory of Open Access Journals (Sweden)

    July E. Carmona-Álvarez

    2015-07-01

    Full Text Available To estimate the effective friction angle of soil from in situ test is a complicated job, due to high rates of strain existing in this kind of tests, which tend to be too invasive and disturb the vicinities of test depth, even the sample that eventually is taken at the site. Likewise, the most of the correlations found in the current bibliography to obtain the effective friction angle using field tests, have been developed for soils from different regions. For that reason when are implemented on tropical soils present high scatter, to compare the field parameter values with real results obtained at the lab. This research aims to use in situ tests define through of analysis of different correlations, which fits adequately to the specific conditions of the piedmont soils of Bogota. For the present study will be utilized data from SPT (widely used in Colombia and SPT-T (never before conducted in the country, carried out considering the appropriated norms to each test, taking in account to SPT-T, doesn’t exist local standard governing such tests. The correlations for field procedures of the tests implemented were for effective confining and energy transference of the SPT hammer, since the state-of-the-art mentions it as the most affect the reliability of the final results. The final results show the tendency of the methodologies used to obtain the correlation, in relation with the real value of effective friction angle from of lab tests.

  14. Tensile strength of concrete under static and intermediate strain rates: Correlated results from different testing methods

    International Nuclear Information System (INIS)

    Wu Shengxing; Chen Xudong; Zhou Jikai

    2012-01-01

    Highlights: ► Tensile strength of concrete increases with increase in strain rate. ► Strain rate sensitivity of tensile strength of concrete depends on test method. ► High stressed volume method can correlate results from various test methods. - Abstract: This paper presents a comparative experiment and analysis of three different methods (direct tension, splitting tension and four-point loading flexural tests) for determination of the tensile strength of concrete under low and intermediate strain rates. In addition, the objective of this investigation is to analyze the suitability of the high stressed volume approach and Weibull effective volume method to the correlation of the results of different tensile tests of concrete. The test results show that the strain rate sensitivity of tensile strength depends on the type of test, splitting tensile strength of concrete is more sensitive to an increase in the strain rate than flexural and direct tensile strength. The high stressed volume method could be used to obtain a tensile strength value of concrete, free from the influence of the characteristics of tests and specimens. However, the Weibull effective volume method is an inadequate method for describing failure of concrete specimens determined by different testing methods.

  15. Viability of gait speed test in hospitalized elderly patients.

    Science.gov (United States)

    Martinez, Bruno Prata; Batista, Anne Karine Menezes Santos; Ramos, Isis Resende; Dantas, Júlio Cesar; Gomes, Isabela Barboza; Forgiarini, Luiz Alberto; Camelier, Fernanda Rosa Warken; Camelier, Aquiles Assunção

    2016-01-01

    The gait speed test (GST) is a physical test that can predict falls and aid in the diagnosis of sarcopenia in the elderly. However, to our knowledge, there have been no studies evaluating its reproducibility in hospitalized elderly patients. The objective of this study was to evaluate the safety and reproducibility of the six-meter GST (6GST) in hospitalized elderly patients. This repeated measures study involved hospitalized elderly patients (≥ 60 years of age) who underwent the 6GST by the fifth day of hospitalization, were able to walk without assistance, and presented no signs of dyspnea or pain that would prevent them from performing the test. The 6GST was performed three times in sequence, with a rest period between each test, in a level corridor. Gait speed was measured in meters/second. Reproducibility was assessed by comparing the means, intraclass correlation coefficients (ICCs) and Bland-Altman plots. We evaluated 110 elderly patients in a total of 330 tests. All participants completed all of the tests. The comparisons between the speeds obtained during the three tests showed high ICCs and a low mean bias (Bland-Altman plots). The correlation and accuracy were greatest when the mean maximum speed was compared with that obtained in the third test (1.26 ± 0.44 m/s vs. 1.22 ± 0.44 m/s; ICC = 0.99; p = 0.001; mean bias = 0.04; and limits of agreement = -0.27 to 0.15). The 6GST was proven to be safe and to have good reproducibility in this sample of hospitalized elderly patients. The third measurement seems to correspond to the maximum speed, since the first two measurements underestimated the actual performance. O teste de velocidade de marcha (TVM) é um teste físico que pode predizer quedas e auxiliar no diagnóstico de sarcopenia em idosos da comunidade. Entretanto, pelo que sabemos, não há estudos que avaliaram sua reprodutibilidade em idosos hospitalizados. O objetivo deste estudo foi avaliar a segurança e a reprodutibilidade do TVM de seis

  16. Validity and reliability of the Baecke questionnaire for the evaluation of habitual physical activity among people living with HIV/AIDS

    Directory of Open Access Journals (Sweden)

    Florindo Alex Antonio

    2006-01-01

    Full Text Available This study evaluates the validity and reliability of the Baecke questionnaire on habitual physical activity when applied to a population of HIV/AIDS subjects. Validity was determined by comparing measurements for 30 subjects of peak oxygen uptake, peak workload, and energy expenditure with scores for occupational physical activity (OPA, physical exercise in leisure (PEL, leisure and locomotion activities (LLA, and total score (TS. Reliability was determined by testing and retesting 29 subjects at intervals of 15-30 days. Validity was evaluated with the Pearson correlation and reliability analyses were done using the intraclass correlation, paired Student t-test, and Bland-Altman methods. Peak VO2 and peak workload had significant correlation with PEL (r = 0.41; r = 0.43; respectively. Energy expenditure had a significant correlation with OPA (r = 0.64. The intraclass coefficients were 0.70 or more for OPA, PEL and TS. There was no difference in OPA, PEL, LLA and TS between the two evaluations. The Bland-Altman methods showed that there was good agreement between the measurements for all habitual physical activities scores. Results show that the Baecke questionnaire is valid for the evaluation of habitual physical activity among people living with HIV/AIDS.

  17. Comparison of Two Sources of Clinical Audit Data to Assess the Delivery of Diabetes Care in Aboriginal Communities.

    Science.gov (United States)

    Regan, Timothy; Paul, Christine; Ishiguchi, Paul; D'Este, Catherine; Koller, Claudia; Forshaw, Kristy; Noble, Natasha; Oldmeadow, Christopher; Bisquera, Alessandra; Eades, Sandra

    2017-10-17

    The objective of this study was to determine the concordance between data extracted from two Clinical Decision Support Systems regarding diabetes testing and monitoring at Aboriginal Community Controlled Health Services in Australia. De-identified PenCAT and Communicare Systems data were extracted from the services allocated to the intervention arm of a diabetes care trial, and intra-class correlations for each extracted item were derived at a service level. Strong to very strong correlations between the two data sources were found regarding the total number of patients with diabetes per service (Intra-class correlation [ICC] = 0.99), as well as the number (ICC = 0.98-0.99) and proportion (ICC = 0.96) of patients with diabetes by gender. The correlation was moderate for the number and proportion of Type 2 diabetes patients per service in the group aged 18-34 years (ICC = 0.65 and 0.8-0.82 respectively). Strong to very strong correlations were found for numbers and proportions of patients being tested for diabetes, and for appropriate monitoring of patients known to have diabetes (ICC = 0.998-1.00). This indicated a generally high degree of concordance between whole-service data extracted by the two Clinical Decision Support Systems. Therefore, the less expensive or less complex option (depending on the individual circumstances of the service) may be appropriate for monitoring diabetes testing and care. However, the extraction of data about subgroups of patients may not be interchangeable.

  18. Test-Retest Reliability and Practice Effects of the Stability Evaluation Test.

    Science.gov (United States)

    Williams, Richelle M; Corvo, Matthew A; Lam, Kenneth C; Williams, Travis A; Gilmer, Lesley K; McLeod, Tamara C Valovich

    2017-01-17

    Postural control plays an essential role in concussion evaluation. The Stability Evaluation Test (SET) aims to objectively analyze postural control by measuring sway velocity on the NeuroCom's VSR portable force platform (Natus, San Carlos, CA). To assess the test-retest reliability and practice effects of the SET protocol. Cohort. Research Laboratory. Fifty healthy adults (males=20, females=30, age=25.30±3.60 years, height=166.60±12.80 cm, mass=68.80±13.90 kg). All participants completed four trials of the SET. Each trial consisted of six 20-second balance tests with eyes closed, under the following conditions: double-leg firm (DFi), single-leg firm (SFi), tandem firm (TFi), double-leg foam (DFo), single-leg foam (SFo), and tandem foam (TFo). Each trial was separated by a 5-minute seated rest period. The dependent variable was sway velocity (deg/sec), with lower values indicating better balance. Sway velocity was recorded for each of the six conditions as well as a composite score for each trial. Test-retest reliability was analyzed across four trials with Intraclass Correlation Coefficients. Practice effects analyzed with repeated measures analysis of variance, followed by Tukey post-hoc comparisons for any significant main effects (preliability values were good to excellent: DFi (ICC=0.88;95%CI:0.81,0.92), SFi (ICC=0.75;95%CI:0.61,0.85), TFi (ICC=0.84;95%CI:0.75,0.90), DFo (ICC=0.83;95%CI:0.74,0.90), SFo (ICC=0.82;95%CI:0.72,0.89), TFo (ICC=0.81;95%CI:0.69,0.88), and composite score (ICC=0.93;95%CI:0.88,0.95). Significant practice effects (preliability for the assessment of postural control in healthy adults. Due to the practice effects noted, a familiarization session is recommended (i.e., all 6 conditions) prior to recording the data. Future studies should evaluate injured patients to determine meaningful change scores during various injuries.

  19. The paced auditory serial addition test for working memory assessment: Psychometric properties

    Science.gov (United States)

    Nikravesh, Maryam; Jafari, Zahra; Mehrpour, Masoud; Kazemi, Roozbeh; Amiri Shavaki, Younes; Hossienifar, Shamim; Azizi, Mohamad Parsa

    2017-01-01

    Background: The paced auditory serial addition test (PASAT) was primarily developed to assess the effects of traumatic brain injury on cognitive functioning. Working memory (WM) is one of the most important aspects of cognitive function, and WM impairment is one of the clinically remarkable signs of aphasia. To develop the Persian version of PASAT, an initial version was used in individuals with aphasia (IWA). Methods: In this study, 25 individuals with aphasia (29-60 years) and 85 controls (18-60 years) were included. PASAT was presented in the form of recorded 61 single-digit numbers (1 to 9). The participants repeatedly added the 2 recent digits. The psychometric properties of PASAT including convergent validity (using the digit memory span tasks), divergent validity (using results in the control group and IWA group), and face validity were investigated. Test-retest reliability was considered as well. Results: The relationship between the PASAT and digit memory span tests was moderate to strong in the control group (forward digit memory span test: r= 0.52, p< 0.0001; backward digit memory span test: r = 0.48, p< 0.0001). A strong relationship was found in IWA (forward digit memory span test: r= 0.72, p< 0.0001; backward digit memory span test: r= 0.53, p= 0.006). Also, strong testretest reliability (intraclass correlation= 0.95, p< 0.0001) was observed. Conclusion: According to our results, the PASAT is a valid and reliable test to assess working memory, particularly in IWA. It could be used as a feasible tool for clinical and research applications. PMID:29445690

  20. Reliability and validity of psychosocial and environmental correlates measures of physical activity and screen-based behaviors among Chinese children in Hong Kong

    Directory of Open Access Journals (Sweden)

    Salmon Jo

    2011-03-01

    Full Text Available Abstract Background Insufficient participation in physical activity and excessive screen time have been observed among Chinese children. The role of social and environmental factors in shaping physical activity and sedentary behaviors among Chinese children is under-investigated. The purpose of the present study was to assess the reliability and validity of a questionnaire to measure child- and parent-reported psychosocial and environmental correlates of physical activity and screen-based behaviors among Chinese children in Hong Kong. Methods A total of 303 schoolchildren aged 9-14 years and their parents volunteered to participate in this study and 160 of them completed the questionnaire twice within an interval of 10 days. Intraclass correlation coefficients (ICCs, kappa statistics, and percent agreement were performed to evaluate test-retest reliability of the continuous and categorical variables, respectively. Exploratory factor analyses (EFAs were conducted to assess convergent validity of the emergent scales. Cronbach's alpha and ICCs were performed to assess internal and test-retest reliability of the emergent scales. Criterion validity was assessed by correlating psychosocial and environmental measures with self-reported physical activity and screen-based behaviors, measured by a validated questionnaire. Results Reliability statistics for both child- and parent-reported continuous variables showed acceptable consistency for all of the ICC values greater than 0.70. Kappa statistics showed fair to perfect test-retest reliability for the categorical items. Adequate internal consistency and test-retest reliability were observed in most of the emergent scales. Criterion validity assessed by correlating psychosocial and environmental measures with child-reported physical activity found associations with physical activity in the self-efficacy scale (r = 0.25, P r = 0.25, P r = 0.14, P r = -0.22, P r = 0.12, P = 0.053. Conclusions The findings

  1. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  2. Behavioral and Psychosocial Correlates of HIV Testing Among Male Clients of Female Sex Workers in Tijuana, Mexico.

    Science.gov (United States)

    Fleming, Paul J; Patterson, Thomas L; Chavarin, Claudia V; Semple, Shirley J; Magis-Rodriguez, Carlos; Pitpitan, Eileen V

    2017-08-01

    We use data collected from a sample of 400 male clients of female sex workers (FSW) to examine their HIV testing behavior. We present frequencies of HIV testing and used bivariate and multivariable analyses to assess its socio-demographic, behavioral, and psychosocial correlates. We found that the majority (55 %) of male clients of FSW in Tijuana, Mexico had never had an HIV test and the prevalence of HIV testing within the past year was low (9 %). In multivariable analyses, significant correlates of having ever tested for HIV were higher age, higher HIV knowledge score, lower sexual compulsiveness score, lower misogynistic attitudes score, having a condom break during sex with a FSW, and higher frequency of sex with a FSW while she was high. Our findings represent an important starting point for developing effective interventions to address the need to promote HIV testing among this population.

  3. Validity of an Interactive Functional Reach Test.

    Science.gov (United States)

    Galen, Sujay S; Pardo, Vicky; Wyatt, Douglas; Diamond, Andrew; Brodith, Victor; Pavlov, Alex

    2015-08-01

    Videogaming platforms such as the Microsoft (Redmond, WA) Kinect(®) are increasingly being used in rehabilitation to improve balance performance and mobility. These gaming platforms do not have built-in clinical measures that offer clinically meaningful data. We have now developed software that will enable the Kinect sensor to assess a patient's balance using an interactive functional reach test (I-FRT). The aim of the study was to test the concurrent validity of the I-FRT and to establish the feasibility of implementing the I-FRT in a clinical setting. The concurrent validity of the I-FRT was tested among 20 healthy adults (mean age, 25.8±3.4 years; 14 women). The Functional Reach Test (FRT) was measured simultaneously by both the Kinect sensor using the I-FRT software and the Optotrak Certus(®) 3D motion-capture system (Northern Digital Inc., Waterloo, ON, Canada). The feasibility of implementing the I-FRT in a clinical setting was assessed by performing the I-FRT in 10 participants with mild balance impairments recruited from the outpatient physical therapy clinic (mean age, 55.8±13.5 years; four women) and obtaining their feedback using a NASA Task Load Index (NASA-TLX) questionnaire. There was moderate to good agreement between FRT measures made by the two measurement systems. The greatest agreement between the two measurement system was found with the Kinect sensor placed at a distance of 2.5 m [intraclass correlation coefficient (2,k)=0.786; PNASA/TLX questionnaire. FRT measures made using the Kinect sensor I-FRT software provides a valid clinical measure that can be used with the gaming platforms.

  4. Correlation between chronic arthritis patients confirmed with questionnaire and serologic test of Lyme disease

    Science.gov (United States)

    Rotan, H.; Ginting, Y.; Loesnihari, R.; Kembaren, T.; Marpaung, B.

    2018-03-01

    Lyme borreliosis is the most common tick-borne disease, and frequency of arthritis complication later. The objective of this study was to determine the seroprevalence of Lyme disease and to evaluate its correlation with chronic arthritis. This epidemiologic cross sectional study included 41 healthy individuals who had chronic arthritis and bitten by ticks underwent questionnaires, and laboratory tests consisted of a routine blood sample, serum uric acid, and IgG ELISA for Lyme. There was 7.32% presence of positive IgG for Lyme. Samples with positive IgG for Lyme were further evaluated for rheumatology marker. We found three samples with a positive rheumatoid factor, two samples had positive anti-MCV, and 1 sample had slightly increased CRP. Three Lyme positive samples had normal EULAR scoring. It was the first Lyme disease case found in Indonesia, particularly in 4 villages of Sibolangit, Deli Serdang, North Sumatera. The assessment made by analysis the questionnaire, evaluation the blood test, and confirmed positive Lyme disease, and at last, we found the correlation between chronic arthritis with positive test Lyme.

  5. Resampling-based methods in single and multiple testing for equality of covariance/correlation matrices.

    Science.gov (United States)

    Yang, Yang; DeGruttola, Victor

    2012-06-22

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.

  6. Test-retest reliability of the Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale.

    Science.gov (United States)

    Gustafsson, Margareta; Blomberg, Karin; Holmefur, Marie

    2015-07-01

    The Clinical Learning Environment, Supervision and Nurse Teacher (CLES + T) scale evaluates the student nurses' perception of the learning environment and supervision within the clinical placement. It has never been tested in a replication study. The aim of the present study was to evaluate the test-retest reliability of the CLES + T scale. The CLES + T scale was administered twice to a group of 42 student nurses, with a one-week interval. Test-retest reliability was determined by calculations of Intraclass Correlation Coefficients (ICCs) and weighted Kappa coefficients. Standard Error of Measurements (SEM) and Smallest Detectable Difference (SDD) determined the precision of individual scores. Bland-Altman plots were created for analyses of systematic differences between the test occasions. The results of the study showed that the stability over time was good to excellent (ICC 0.88-0.96) in the sub-dimensions "Supervisory relationship", "Pedagogical atmosphere on the ward" and "Role of the nurse teacher". Measurements of "Premises of nursing on the ward" and "Leadership style of the manager" had lower but still acceptable stability (ICC 0.70-0.75). No systematic differences occurred between the test occasions. This study supports the usefulness of the CLES + T scale as a reliable measure of the student nurses' perception of the learning environment within the clinical placement at a hospital. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Test-retest reliability of Physical Activity Neighborhood Environment Scale among urban men and women in Nanjing, China.

    Science.gov (United States)

    Zhao, L; Wang, Z; Qin, Z; Leslie, E; He, J; Xiong, Y; Xu, F

    2018-03-01

    The identification of physical-activity-friendly built environment (BE) constructs is highly useful for physical activity promotion and maintenance. The Physical Activity Neighborhood Environment Scale (PANES) was developed for assessing BE correlates. However, PANES reliability has not been investigated among adults in China. A cross-sectional study. With multistage sampling approaches, 1568 urban adults (aged 35-74 years) were recruited for the initial survey on all 17 items of PANES Chinese version (PANES-CHN), with the survey repeated 7 days later for each participant. Intraclass correlation coefficient (ICC) was used to assess the test-retest reliability of PANES-CHN for each item. Totally, 1551 participants completed both surveys (follow-up rate = 98.9%). Among participants (mean age: 54.7 ± 11.1 years), 47.8% were men, 22.1% were elders, and 22.7% had ≥13 years of education. Overall, the PANES-CHN demonstrated at least substantial reliability with ICCs ranging from 0.66 to 0.95 (core items), from 0.75 to 0.95 (recommended items), and from 0.78 to 0.87 (optional items). Similar outcomes were observed when data were analyzed by gender or age groups. The PANES-CHN has excellent test-retest reliability and thus has valuable utility for assessing urban BE attributes among Chinese adults. Copyright © 2017 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  8. Correlation potential of a test ion near a strongly charged plate.

    Science.gov (United States)

    Lu, Bing-Sui; Xing, Xiangjun

    2014-03-01

    We analytically calculate the correlation potential of a test ion near a strongly charged plate inside a dilute m:-n electrolyte. We do this by calculating the electrostatic Green's function in the presence of a nonlinear background potential, the latter having been obtained using the nonlinear Poisson-Boltzmann theory. We consider the general case where the dielectric constants of the plate and the electrolyte are distinct. The following generic results emerge from our analyses: (1) If the distance to the plate Δz is much larger than a Gouy-Chapman length, the plate surface will behave effectively as an infinitely charged surface, and the dielectric constant of the plate effectively plays no role. (2) If Δz is larger than a Gouy-Chapman length but shorter than a Debye length, the correlation potential can be interpreted in terms of an image charge that is three times larger than the source charge. This behavior is independent of the valences of the ions. (3) The Green's function vanishes inside the plate if the surface charge density is infinitely large; hence the electrostatic potential is constant there. In this respect, a strongly charged plate behaves like a conductor plate. (4) If Δz is smaller than a Gouy-Chapman length, the correlation potential is dominated by the conventional image charge due to the dielectric discontinuity at the interface. (5) If Δz is larger than a Debye length, the leading order behavior of the correlation potential will depend on the valences of the ions in the electrolyte. Furthermore, inside an asymmetric electrolyte, the correlation potential is singly screened, i.e., it undergoes exponential decay with a decay width equal to the Debye length.

  9. Risk of false decision on conformity of a multicomponent material when test results of the components' content are correlated.

    Science.gov (United States)

    Kuselman, Ilya; Pennecchi, Francesca R; da Silva, Ricardo J N B; Hibbert, D Brynn

    2017-11-01

    The probability of a false decision on conformity of a multicomponent material due to measurement uncertainty is discussed when test results are correlated. Specification limits of the components' content of such a material generate a multivariate specification interval/domain. When true values of components' content and corresponding test results are modelled by multivariate distributions (e.g. by multivariate normal distributions), a total global risk of a false decision on the material conformity can be evaluated based on calculation of integrals of their joint probability density function. No transformation of the raw data is required for that. A total specific risk can be evaluated as the joint posterior cumulative function of true values of a specific batch or lot lying outside the multivariate specification domain, when the vector of test results, obtained for the lot, is inside this domain. It was shown, using a case study of four components under control in a drug, that the correlation influence on the risk value is not easily predictable. To assess this influence, the evaluated total risk values were compared with those calculated for independent test results and also with those assuming much stronger correlation than that observed. While the observed statistically significant correlation did not lead to a visible difference in the total risk values in comparison to the independent test results, the stronger correlation among the variables caused either the total risk decreasing or its increasing, depending on the actual values of the test results. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Examining the Purdue Pegboard Test for Occupational Therapy Practice

    Directory of Open Access Journals (Sweden)

    Debra Lindstrom-Hazel

    2015-07-01

    Full Text Available Background: Occupational therapy ethics require that therapists use current assessment tools that provide useful comparison data. When an assessment only has normative data that is more than 40 years old, it cannot be considered current. The purpose of this study was to examine the past and current use of the Purdue Pegboard Test by occupational therapists and other professionals and to determine if it is beneficial to conduct a large normative study on the Purdue Pegboard Assembly Task (PPAT in order to bring the test up to date. Method: This was a psychometric study of inter-rater reliability and a small normative study of the PPAT with 150 healthy working adults from MI. Descriptive statistics were used for normative means, standard deviations, and standard errors of measurement. Results: Inter-rater reliability was measured using the intra-class correlation coefficient for the mean of all student-rating teams of seven occupational therapy students. The result of the psychometric study determined the ICC was above .99. During the normative study, 150 participants performed the PPAT for three trials. Norms for gender and ages 18-49 and 50-62 are presented. Conclusion: The result of the inter-rater reliability test determined that OT students can be reliable raters for the PPAT. The normative study collected current norms for healthy working adults in MI, but validity testing and a larger normative study is needed to bring the psychometrics of the PPAT up to date to be generalized for current use by occupational therapists.

  11. Development of a simple computerized torsion test to quantify subjective ocular torsion.

    Science.gov (United States)

    Kim, Y D; Yang, H K; Hwang, J-M

    2017-11-01

    PurposeThe double Maddox-rod test (DMRT) and Lancaster red-green test (LRGT) are the most widely used tests worldwide to assess subjective ocular torsion. However, these tests require equipment and the quantified results of ocular torsion are only provided in rough values. Here we developed a novel computerized torsion test (CTT) for individual assessment of subjective ocular torsion and validated the reliability and accuracy of the test compared with those of the DMRT and LRGT.MethodsA total of 30 patients with cyclovertical strabismus and 30 controls were recruited. The CTT was designed using Microsoft Office PowerPoint. Subjects wore red-green filter spectacles and viewed gradually tilted red and cyan lines on an LCD monitor and pressed the keyboard to go through the slides, until both lines seemed parallel. All subjects underwent the CTT, DMRT, and LRGT. Intraclass correlation coefficients and Bland-Altman plots were analyzed to assess the acceptability of the CTT compared with that of the DMRT.ResultsBoth the DMRT and CTT showed no significant test-retest differences in the strabismus and control groups. The DMRT and CTT results demonstrated an acceptable agreement. The reliability of the CTT was better than that of the DMRT. The LRGT showed low sensitivity for the detection of ocular torsion compared with the DMRT (40.0%) and CTT (39.1%).ConclusionOur results suggest that the assessment of subjective ocular torsion using the CTT based on PowerPoint software is simple, reproducible, and accurate and can be applied in clinical practice.

  12. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    Science.gov (United States)

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  13. Measurement of acute nonspecific low back pain perception in primary care physical therapy: reliability and validity of the brief illness perception questionnaire.

    Science.gov (United States)

    Hallegraeff, Joannes M; van der Schans, Cees P; Krijnen, Wim P; de Greef, Mathieu H G

    2013-02-01

    The eight-item Brief Illness Perception Questionnaire is used as a screening instrument in physical therapy to assess mental defeat in patients with acute low back pain, besides patient perception might determine the course and risk for chronic low back pain. However, the psychometric properties of the Brief Illness Perception Questionnaire in common musculoskeletal disorders like acute low back pain have not been adequately studied. Patients' perceptions vary across different populations and affect coping styles. Thus, our aim was to determine the internal consistency, test-retest reliability and validity of the Dutch language version of the Brief Illness Perception Questionnaire in acute non-specific low back pain patients in primary care physical therapy. A non-experimental cross-sectional study with two measurements was performed. Eighty-four acute low back pain patients, in multidisciplinary health care center in Dutch primary care with a sample mean (SD) age of 42 (12) years, participated in the study. Internal consistency (Cronbach's α) and test-retest procedures (Intraclass Correlation Coefficients and limits of agreement) were evaluated at a one-week interval. The concurrent validity of the Brief Illness Perception Questionnaire was examined by using the Mental Health Component of the Short Form 36 Health Survey. The Cronbach's α for internal consistency was 0.73 (95% CI, 0.67 - 0.83); and the Intraclass Correlation Coefficient test-retest reliability was acceptable: 0.72 (95% CI, 0.53 - 0.82), however, the limits of agreement were large. The Intraclass Correlation Coefficient measuring concurrent validity 0.65 (95% CI, 0.46 - 0.80). The Dutch version of the Brief Illness Perception Questionnaire is an appropriate instrument for measuring patients' perceptions in acute low back pain patients, showing acceptable internal consistency and reliability. Concurrent validity is adequate, however, the instrument may be unsuitable for detecting changes in low

  14. Reliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis

    Science.gov (United States)

    Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.

    2014-01-01

    BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281

  15. Psychometric evaluation of a motor control test battery of the craniofacial region.

    Science.gov (United States)

    von Piekartz, H; Stotz, E; Both, A; Bahn, G; Armijo-Olivo, S; Ballenberger, N

    2017-12-01

    The primary objective of this study was to determine the structural and known-group validity as well as the inter-rater reliability of a test battery to evaluate the motor control of the craniofacial region. Seventy volunteers without TMD and 25 subjects with TMD (Axes I) per the DC/TMD were asked to execute a test battery consisting of eight tests. The tests were video-taped in the same sequence in a standardised manner. Two experienced physical therapists participated in this study as blinded assessors. We used exploratory factor analysis to identify the underlying component structure of the eight tests. Internal consistency (Cronbach's α), inter-rater reliability (intra-class correlation coefficient) and construct validity (ie, hypothesis testing-known-group validity) (receiver operating curves) were also explored for the test battery. The structural validity showed the presence of one factor underlying the construct of the test battery. The internal consistency was excellent (0.90) as well as the inter-rater reliability. All values of reliability were close to 0.9 or above indicating very high inter-rater reliability. The area under the curve (AUC) was 0.93 for rater 1 and 0.94 for rater two, respectively, indicating excellent discrimination between subjects with TMD and healthy controls. The results of the present study support the psychometric properties of test battery to measure motor control of the craniofacial region when evaluated through videotaping. This test battery could be used to differentiate between healthy subjects and subjects with musculoskeletal impairments in the cervical and oro-facial regions. In addition, this test battery could be used to assess the effectiveness of management strategies in the craniofacial region. © 2017 John Wiley & Sons Ltd.

  16. An Ecological Study of Anterior Cruciate Ligament Reconstruction, Part 2: Functional Performance Tests Correlate With Return-to-Sport Outcomes.

    Science.gov (United States)

    McGrath, Timothy M; Waddington, Gordon; Scarvell, Jennie M; Ball, Nick; Creer, Rob; Woods, Kevin; Smith, Damian; Adams, Roger

    2017-02-01

    Additional high-quality prospective studies are needed to better define the objective criteria used in relation to return-to-sport decisions after anterior cruciate ligament (ACL) reconstruction in active populations. To investigate prospectively the relationship between functional performance test results at 24 weeks postoperative and return-to-sport activity (Tegner activity score) at 12 and 24 months, respectively, after synthetic (ligament advanced reinforcement system [LARS]) and autograft (doubled semitendinosus/gracilis [2ST/2GR]) ACL reconstructions. Case series; Level of evidence, 4. A total of 64 patients who underwent ACL reconstruction (32 LARS, 32 2ST/2GR autograft; mean age, 27.9 years; body mass index [BMI], 24.9 kg/m 2 ) were assessed preoperatively and at staged intervals postoperatively up to 24 weeks for isokinetic testing of quadriceps and hamstring average power per repetition at 60 deg/s and 180 deg/s, a battery of hop tests, peak vertical ground-reaction force (vGRF), and time to peak vGRF (in seconds) during a step- and jump-down task onto a force platform and peak speed (m/s) using a global positioning system (GPS unit) during a running task. A cohort of 32 healthy matched participants (mean age, 26.31 years; BMI, 25.7 kg/m 2 ) were also tested to act as reference. Pearson correlation was calculated to assess correlation of each performance measure at 24 weeks postoperative with activity outcomes (Tegner score) at 12 and 24 months. The strongest correlation between physical performance tests and return-to-sport outcomes was observed with peak speed during running. Large correlations were also observed for hamstring isokinetic power and hop test for distance. Moderate correlations were observed for timed hop, peak vGRF during a jump-down task, and quadriceps isokinetic power. No statistical correlations were observed for time to peak vGRF during a step-down and jump-down task as well as peak vGRF during a step-down task. When the performance

  17. The King-Devick test for sideline concussion screening in collegiate football.

    Science.gov (United States)

    Leong, Danielle F; Balcer, Laura J; Galetta, Steven L; Evans, Greg; Gimre, Matthew; Watt, David

    2015-01-01

    Sports-related concussion has received increasing attention as a result of neurologic sequelae seen among athletes, highlighting the need for a validated, rapid screening tool. The King-Devick (K-D) test requires vision, eye movements, language function and attention in order to perform and has been proposed as a promising tool for assessment of concussion. We investigated the K-D test as a sideline screening tool in a collegiate cohort to determine the effect of concussion. Athletes (n=127, mean age 19.6±1.2 years) from the Wheaton College football and men's and women's basketball teams underwent baseline K-D testing at pre-season physicals for the 2012-2013 season. K-D testing was administered immediately on the sidelines for football players with suspected head injury during regular games and changes compared to baseline were determined. Post-season testing was also performed to compare non-concussed athletes' test performance. Concussed athletes (n=11) displayed sideline K-D scores that were significantly higher (worse) than baseline (36.5±5.6s vs. 31.3±4.5s, pWilcoxon signed-rank test). Post-season testing demonstrated improvement of scores and was consistent with known learning effects (35.1±5.2s vs. 34.4±5.0s, pWilcoxon signed-rank test). Test-retest reliability was analyzed between baseline and post-season administrations of the K-D test resulting in high levels of test-retest reliability (intraclass correlation coefficient (ICC)=0.95 [95% Confidence Interval 0.85-1.05]). The data show worsening of K-D test scores following concussion further supporting utility of the K-D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  18. Reliability of the Star Excursion Balance Test and Two New Similar Protocols to Measure Trunk Postural Control.

    Science.gov (United States)

    López-Plaza, Diego; Juan-Recio, Casto; Barbado, David; Ruiz-Pérez, Iñaki; Vera-Garcia, Francisco J

    2018-05-18

    Although the Star Excursion Balance test (SEBT) has shown a good intrasession reliability, the intersession reliability of this test has not been deeply studied. Furthermore, there is an evident high influence of the lower limbs in the performance of the SEBT, so even if it has been used to measure core stability, it is possibly not the most suitable measurement. The aims of this study were to (1) to assess the absolute and relative between-session reliability of the SEBT and 2 novel variations of this test to assess trunk postural control while sitting, ie, the Star Excursion Sitting Test (SEST) and the Star Excursion Timing Test (SETT); and (2) to analyze the relationships between these 3 test scores. Correlational and reliability test-retest study. Controlled laboratory environment. Twenty-seven physically active men (age: 24.54 ± 3.05 years). Relative and absolute reliability of the SEBT, SEST, and SETT were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM), respectively. A Pearson correlation analysis was carried out between the variables of the 3 tests. Maximum normalized reach distances were assessed for different SEBT and SEST directions. In addition, composite indexes were calculated for SEBT, SEST, and SETT. The SEBT (dominant leg: ICC = 0.87 [0.73-0.94], SEM = 2.12 [1.66-2.93]; nondominant leg: ICC = 0.74 [0.50-0.87], SEM = 3.23 [2.54-4.45]), SEST (ICC = 0.85 [0.68-0.92], SEM = 1.27 [1.03-1.80]), and SETT (ICC = 0.61 [0.30-0.80], SEM = 2.31 [1.82-3.17]) composite indexes showed moderate-to-high 1-month reliability. A learning effect was detected for some SEBT and SEST directions and for SEST and SETT composite indexes. No significant correlations were found between SEBT and its 2 variations (r ≤ .366; P > .05). A significant correlation was found between the SEST and SETT composite indexes (r = .520; P > .01). SEBT, SEST, and SETT are reliable field protocols to measure postural control. However

  19. Psychometric properties of the Malay Version of the hospital anxiety and depression scale: a study of husbands of breast cancer patients in Kuala Lumpur, Malaysia.

    Science.gov (United States)

    Yusoff, Nasir; Low, Wah Yun; Yip, Cheng-Har

    2011-01-01

    The main objective of this paper is to examine the psychometric properties of the Malay Version of the Hospital Anxiety and Depression Scale (HADS), tested on 67 husbands of the women who were diagnosed with breast cancer. The eligible husbands were retrieved from the Clinical Oncology Clinic at three hospitals in Kuala Lumpur, Malaysia. Data was collected at three weeks and ten weeks following surgery for breast cancer of their wives. The psychometric properties of the HADS were reported based on Cronbach' alpha, Intraclass Correlation Coefficients (ICC), Effect Size Index (ESI), sensitivity and discriminity of the scale. Internal consistency of the scale is excellent, with Cronbach's alpha of 0.88 for Anxiety subscale and 0.79 for Depression subscale. Test-retest Intraclass Correlation Coefficient (ICC) is 0.35 and 0.42 for Anxiety and Depression Subscale, respectively. Small mean differences were observed at test-retest measurement with ESI of 0.21 for Anxiety and 0.19 for Depression. Non-significant result was revealed for the discriminant validity (mastectomy vs lumpectomy). The Malay Version of the HADS is appropriate to measure the anxiety and depression among the husbands of the women with breast cancer in Malaysia.

  20. Testing the psychometric properties of a Chinese version of the level of expressed emotion scale.

    Science.gov (United States)

    Chien, Wai Tong; Chan, Zenobia Chung-Yee; Chan, Sally Wai-Chi

    2014-01-01

    This study tested the psychometric properties of a Chinese version of the level of expressed emotion scale in Hong Kong Chinese patients with severe mental illness and their family caregivers. First, the semantic equivalence with the original English version and test-retest reliability at 2-week interval of the Chinese version was examined. After that, the reproducibility, construct validity, and internal consistency of the Chinese version were tested. The Chinese version indicated good semantic equivalence with the English version (kappa values = 0.76-0.95 and ICC = 0.81-0.92), test-retest reliability (r = 0.89-0.95, P Chinese version had substantial loadings on one of the four factors identified (intrusiveness/hostility, attitude towards patient, tolerance, and emotional involvement), accounting for 71.8% of the total variance of expressed emotion. In confirmatory factor analysis, the identified four-factor model showed the best fit based on all fit indices (χ (2)/df = 1.93, P = 0.75; AGFI = 0.96; TLI = 1.02; RMSEA = 0.031; WRMR = 0.78) to the collected data. The four-factor Chinese version also indicated a good concurrent validity with significant correlations with family functioning (r = -0.54) and family burden (r = 0.49) and a satisfactory reproducibility over six months (intraclass correlation coefficient of 0.90). The mean scores of the overall and subscale of the Chinese version in patients with unipolar disorder were higher than in other illness groups (schizophrenia, psychotic disorders, and bipolar disorder; P Chinese version demonstrates sound psychometric properties to measure families' expressed emotion in Chinese patients with severe mental illness, which are found varied across countries.

  1. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    Science.gov (United States)

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  3. A pilot investigation of the Motivation Behaviors Checklist (MBC): An observational rating scale of effort towards testing for baseline sports-concussion assessment.

    Science.gov (United States)

    Rabinowitz, Amanda R; Merritt, Victoria; Arnett, Peter A

    2016-08-01

    Baseline neuropsychological testing is commonly used in the management of sports-related concussion. However, underperformance due to poor effort could lead to invalid conclusions regarding postconcussion cognitive decline. We designed the Motivation Behaviors Checklist (MBC) as an observational rating scale to assess effort towards baseline neuropsychological testing. Here we present preliminary data in support of its reliability and validity. MBC items were generated based on the consensus of a panel of graduate students, undergraduates, and a clinical neuropsychologist who conduct neuropsychological evaluations for a sports concussion management program. A total of 261 college athletes were administered a standard neuropsychological test battery in addition to the MBC. A subset of evaluations (n= 101) was videotape and viewed by a second rater. Exploratory factor analysis (EFA) was used to refine the scale, and reliability and validity were evaluated. EFA revealed that the MBC items represent four latent factors-Complaints, Poor Focus, Psychomotor Agitation, and Impulsivity. Reliability analyses demonstrated that the MBC has good inter-rater reliability (intraclass correlation coefficient, ICC = .767) and internal consistency (α = .839). The construct validity of the MBC is supported by large correlations with examiners' ratings of effort (ρ = -.623) and medium-sized relationships with cognitive performance and self-ratings of effort (|ρ| between .263 and .345). Discriminant validity was supported by nonsignificant correlations with measures of depression and postconcussion symptoms (ρ = .056 and .082, respectively). These findings provide preliminary evidence that the MBC could be a useful adjunct to baseline neuropsychological evaluations for sports-concussion management.

  4. The reliability and validity of the standardized Mensendieck test in relation to disability in patients with chronic pain.

    Science.gov (United States)

    Keessen, Paul; Maaskant, Jolanda; Visser, Bart

    2018-08-01

    The standardized Mensendieck test (SMT) was developed to quantify posture, movement, gait, and respiration. In the hands of an experienced therapist, the SMT is proven to be a reliable tool. It is unclear whether posture, movement, gait, and respiration are related to the degree of functional disability in patients with chronic pain. The objective of this study was to assess the reliability and convergent validity of the SMT in a heterogeneous sample of 50 patients with chronic pain. Internal consistency was determined by Cronbach's α and interrater reliability by the intraclass correlation coefficient (ICC). Convergent validity was assessed by determining the Spearman rank correlation coefficient between the movement quality measured in the SMT and functional limitation measured on the disability rating index (DRI). The internal consistency was Cronbach's α 0.91. Substantial reliability was found for the items: movement (ICC = 0.68), gait (ICC = 0.69), sitting posture (ICC = 0.63), and respiration (ICC = 0.64). Insufficient reliability was found for standing posture (ICC = 0.23). A moderate correlation was found between average test score SMT and the DRI (r = -0.37) and respiration and DRI (r = -0.45). The SMT is a reasonably reliable tool to assess movement, gait, sitting posture, and respiration. None of the items in the domain standing posture has sufficient reliability. A thorough study of this domain should be considered. The results show little evidence for convergent validity. Several items of the SMT correlated moderately with functional limitation with the DRI. These items were global movement, hip flexion, pelvis rotation, and all respiration items.

  5. Addenbrooke's cognitive examination III: diagnostic utility for mild cognitive impairment and dementia and correlation with standardized neuropsychological tests.

    Science.gov (United States)

    Matias-Guiu, Jordi A; Cortés-Martínez, Ana; Valles-Salgado, Maria; Rognoni, Teresa; Fernández-Matarrubia, Marta; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Addenbrooke's Cognitive Examination III (ACE-III) is a screening test that was recently validated for diagnosing dementia. Since it assesses attention, language, memory, fluency, and visuospatial function separately, it may also be useful for general neuropsychological assessments. The aim of this study was to analyze the tool's ability to detect early stages of Alzheimer's disease and to examine the correlation between ACE-III scores and scores on standardized neuropsychological tests. Our study included 200 participants categorized as follows: 25 healthy controls, 48 individuals with subjective memory complaints, 47 patients with amnestic mild cognitive impairment and 47 mild Alzheimer's disease, and 33 patients with other neurodegenerative diseases. The ACE-III memory and language domains were highly correlated with the neuropsychological tests specific to those domains (Pearson correlation coefficient of 0.806 for total delayed recall on the Free and Cued Selective Reminding Test vs. 0.744 on the Boston Naming Test). ACE-III scores discriminated between controls and patients with amnestic mild cognitive impairment (AUC: 0.906), and between controls and patients with mild Alzheimer's disease (AUC: 0.978). Our results suggest that ACE-III is a useful neuropsychological test for assessing the cognitive domains of attention, language, memory, and visuospatial function. It also enables detection of Alzheimer's disease in early stages.

  6. Normative values for the unipedal stance test with eyes open and closed.

    Science.gov (United States)

    Springer, Barbara A; Marin, Raul; Cyhan, Tamara; Roberts, Holly; Gill, Norman W

    2007-01-01

    Limited normative data are available for the unipedal stance test (UPST), making it difficult for clinicians to use it confidently to detect subtle balance impairments. The purpose of this study was to generate normative values for repeated trials of the UPST with eyes opened and eyes closed across age groups and gender. This prospective, mixed-model design was set in a tertiary care medical center. Healthy subjects (n= 549), 18 years or older, performed the UPST with eyes open and closed. Mean and best of 3 UPST times for males and females of 6 age groups (18-39, 40-49, 50-59, 60-69, 70-79, and 80+) were documented and inter-rater reliability was tested. There was a significant age dependent decrease in UPST time during both conditions. Inter-rater reliability for the best of 3 trials was determined to be excellent with an intra-class correlation coefficient of 0.994 (95% confidence interval 0.989-0.996) for eyes open and 0.998 (95% confidence interval 0.996-0.999) for eyes closed. This study adds to the understanding of typical performance on the UPST. Performance is age-specific and not related to gender. Clinicians now have more extensive normative values to which individuals can be compared.

  7. The Reliability of a Functional Agility Test for Water Polo

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2014-07-01

    Full Text Available Few functional agility tests for water polo take into consideration its specific characteristics. The preliminary objective of this study was to evaluate the reliability of an agility test for water polo players. Fifteen players (16.3 ± 1.8 years old with a minimum of two years of competitive experience were evaluated. A Functional Test for Agility Performance (FTAP was designed to represent the context of this sport. Several trials were performed to familiarize the athlete with the movement. Two experienced coaches measured three repetitions of the FTAP. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. It was considered that certain criteria of reliability measures were met. There was no significant difference between the repetitions, which may be explained by an effect of the evaluator, the ability of the players or fatigue (p > 0.05. The ICC average from evaluators was high (0.88. The SEM varied between 0.13 s and 0.49 s. The CV average considering each individual was near 6-7%. These values depended on the condition of measurement. As the FTAP contains some characteristics that create a degree of unpredictability, the same athlete may reach different performance results, increasing variability. An adjustment in the sample, familiarization and careful selection of subjects help to improve this situation and enhance the reliability of the indicators.

  8. Correlations between the simulated military tasks performance and physical fitness tests at high altitude

    Directory of Open Access Journals (Sweden)

    Eduardo Borba Neves

    2017-11-01

    Full Text Available The aim of this study was to investigate the Correlations between the Simulated Military Tasks Performance and Physical Fitness Tests at high altitude. This research is part of a project to modernize the physical fitness test of the Colombian Army. Data collection was performed at the 13th Battalion of Instruction and Training, located 30km south of Bogota D.C., with a temperature range from 1ºC to 23ºC during the study period, and at 3100m above sea level. The sample was composed by 60 volunteers from three different platoons. The volunteers start the data collection protocol after 2 weeks of acclimation at this altitude. The main results were the identification of a high positive correlation between the 3 Assault wall in succession and the Simulated Military Tasks performance (r = 0.764, p<0.001, and a moderate negative correlation between pull-ups and the Simulated Military Tasks performance (r = -0.535, p<0.001. It can be recommended the use of the 20-consecutive overtaking of the 3 Assault wall in succession as a good way to estimate the performance in operational tasks which involve: assault walls, network of wires, military Climbing Nets, Tarzan jump among others, at high altitude.

  9. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    Science.gov (United States)

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  10. A general statistical test for correlations in a finite-length time series.

    Science.gov (United States)

    Hanson, Jeffery A; Yang, Haw

    2008-06-07

    The statistical properties of the autocorrelation function from a time series composed of independently and identically distributed stochastic variables has been studied. Analytical expressions for the autocorrelation function's variance have been derived. It has been found that two common ways of calculating the autocorrelation, moving-average and Fourier transform, exhibit different uncertainty characteristics. For periodic time series, the Fourier transform method is preferred because it gives smaller uncertainties that are uniform through all time lags. Based on these analytical results, a statistically robust method has been proposed to test the existence of correlations in a time series. The statistical test is verified by computer simulations and an application to single-molecule fluorescence spectroscopy is discussed.

  11. Strength and deformability of hollow concrete blocks: correlation of block and cylindrical sample test results

    OpenAIRE

    Barbosa, C. S.; Hanai, J.B.

    2009-01-01

    This paper deals with correlations among mechanical properties of hollow blocks and those of concrete used to make them. Concrete hollow blocks and test samples were moulded with plastic consistency concrete, to assure the same material in all cases, in three diferente levels of strength (nominally 10 N/mm², 20 N/mm² and 30 N/mm²). The mechanical properties and structural behaviour in axial compression and tension tests were determined by standard tests in blocks and cylinders. Stress and str...

  12. The Unsupported Upper Limb Exercise Test in People Without Disabilities: Assessing the Within-Day Test-Retest Reliability and the Effects of Age and Gender.

    Science.gov (United States)

    Oliveira, Ana; Cruz, Joana; Jácome, Cristina; Marques, Alda

    2018-01-01

    Purpose: To estimate the within-day test-retest reliability and standard error of measurement (SEM) of the unsupported upper limb exercise test (UULEX) in adults without disabilities and to determine the effects of age and gender on performance of the UULEX. Method: A cross-sectional study was conducted with 100 adults without disabilities (44 men, mean age 44.2 [SD 26] y; 56 women, mean age 38.1 [SD 24.1] y). Participants performed three UULEX tests to establish within-day reliability, measured using an intra-class correlation coefficient (ICC) model 2 (two-way random effects) with a single rater (ICC[2,1]) and SEM. The effects of age and gender were examined using two-factor mixed-design analysis of variance (ANOVA) and one-way repeated-measures ANOVA. For analysis purposes, four sub-groups were created: younger adults, older adults, men, and women. Results: Excellent within-day reliability and a small SEM were found in the four sub-groups (younger adults: ICC[2,1]=0.88; 95% CI: 0.82, 0.92; SEM∼40 s; older adults: ICC[2,1]=0.82; 95% CI: 0.72, 0.90; SEM∼50 s; men: ICC[2,1]=0.93; 95% CI: 0.88, 0.96; SEM∼30 s; women: ICC[2,1]=0.85; 95% CI: 0.78, 0.91; SEM∼45 s). Younger adults took, on average, 308.24 seconds longer than older adults to perform the test; older adults performed significantly better on the third test ( p 0.05). Conclusion: The within-day test-retest reliability and SEM values of the UULEX may be used to define the magnitude of the error obtained with repeated measures. One UULEX test seems to be adequate for younger adults to achieve reliable results, whereas three tests seem to be needed for older adults.

  13. Tests of stepping as indicators of mobility, balance, and fall risk in balance-impaired older adults.

    Science.gov (United States)

    Cho, Be-long; Scarpace, Diane; Alexander, Neil B

    2004-07-01

    To determine the relationships between two tests of stepping ability (the maximal step length (MSL) and rapid step test (RST)) and standard tests of standing balance, gait, mobility, and functional impairment in a group of at-risk older adults. Cross-sectional study. University-based laboratory. One hundred sixty-seven mildly balance-impaired older adults recruited for a balance-training and fall-reduction program (mean age 78, range 65-90). Measures of stepping maximally (MSL, the ability to maximally step out and return to the initial position) and rapidly (RST, the time taken to step out and return in multiple directions as fast as possible); standard measures of balance, gait, and mobility including timed tandem stance (TS), tandem walk (TW, both timing and errors), timed unipedal stance (US), timed up and go (TUG), performance oriented mobility assessment (POMA), and 6-minute walk (SMW); measures of leg strength (peak knee and ankle torque and power at slow and fast speeds); self-report measures of frequent falls (>2 per 12 months), disability (Established Population for Epidemiologic Studies of the Elderly (EPESE) physical function), and confidence to avoid falls (Activity-specific Balance Confidence (ABC) Scale). Spearman and Pearson correlation, intraclass correlation coefficient, logistic regression, and linear regression were used for data analysis. MSL consistently predicted a number of self-report and performance measures at least as well as other standard balance measures. MSL correlations with EPESE physical function, ABC, TUG, and POMA scores; SMW; and peak maximum knee and ankle torque and power were at least as high as those correlations seen with TS, TW, or US. MSL score was associated with the risk of being a frequent faller. In addition, the six MSL directions were highly correlated (up to 0.96), and any one of the leg directions yielded similar relationships with functional measures and a history of falls. Relationships between RST and these

  14. SUSCEPTIBILITY TEST FOR FUNGI: CLINICAL AND LABORATORIAL CORRELATIONS IN MEDICAL MYCOLOGY

    Directory of Open Access Journals (Sweden)

    Ana ALASTRUEY-IZQUIERDO

    2015-09-01

    Full Text Available SUMMARYDuring recent decades, antifungal susceptibility testing has become standardized and nowadays has the same role of the antibacterial susceptibility testing in microbiology laboratories. American and European standards have been developed, as well as equivalent commercial systems which are more appropriate for clinical laboratories. The detection of resistant strains by means of these systems has allowed the study and understanding of the molecular basis and the mechanisms of resistance of fungal species to antifungal agents. In addition, many studies on the correlation of in vitro results with the outcome of patients have been performed, reaching the conclusion that infections caused by resistant strains have worse outcome than those caused by susceptible fungal isolates. These studies have allowed the development of interpretative breakpoints for Candida spp. and Aspergillus spp., the most frequent agents of fungal infections in the world. In summary, antifungal susceptibility tests have become essential tools to guide the treatment of fungal diseases, to know the local and global disease epidemiology, and to identify resistance to antifungals.

  15. Thermal Vacuum Test Correlation of a Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytical Model

    Science.gov (United States)

    Mckim, Stephen A.

    2016-01-01

    This thesis describes the development and correlation of a thermal model that forms the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented are presented. The thermal model was correlated to within plus or minus 3 degrees Celsius of the thermal vacuum test data, and was determined sufficient to make future propellant predictions on MMS. The model was also found to be relatively sensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed to improve temperature predictions in the upper hemisphere of the propellant tank where predictions were found to be 2 to 2.5 C lower than the test data. A road map for applying the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

  16. Test-retest reliability of pulse amplitude tonometry measures of vascular endothelial function: implications for clinical trial design.

    Science.gov (United States)

    McCrea, Cindy E; Skulas-Ray, Ann C; Chow, Mosuk; West, Sheila G

    2012-02-01

    Endothelial dysfunction is an important outcome for assessing vascular health in intervention studies. However, reliability of the standard non-invasive method (flow-mediated dilation) is a significant challenge for clinical applications and multicenter trials. We evaluated the repeatability of pulse amplitude tonometry (PAT) to measure change in pulse wave amplitude during reactive hyperemia (Itamar Medical Ltd, Caesarea, Israel). Twenty healthy adults completed two PAT tests (mean interval = 19.5 days) under standardized conditions. PAT-derived measures of endothelial function (reactive hyperemia index, RHI) and arterial stiffness (augmentation index, AI) showed strong repeatability (intra-class correlations = 0.74 and 0.83, respectively). To guide future research, we also analyzed sample size requirements for a range of effect sizes. A crossover design powered at 0.90 requires 28 participants to detect a 15% change in RHI. Our study is the first to show that PAT measurements are repeatable in adults over an interval greater than 1 week.

  17. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment.

    Science.gov (United States)

    Nornoo, Adwoa O; Jackson, Jonathan; Axtell, Samantha

    2017-03-25

    Objective. To determine whether there is a correlation between pharmacy students' scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman's rho correlation test was performed. Results. A very weak but significant positive correlation was found between students' grades on the assignment and their overall HSRT score (r=0.19, p critical-thinking skills in pharmacy students.

  18. Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.

    Science.gov (United States)

    Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward

    2018-01-01

    The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.

  19. Sample size for estimation of the Pearson correlation coefficient in cherry tomato tests

    Directory of Open Access Journals (Sweden)

    Bruno Giacomini Sari

    2017-09-01

    Full Text Available ABSTRACT: The aim of this study was to determine the required sample size for estimation of the Pearson coefficient of correlation between cherry tomato variables. Two uniformity tests were set up in a protected environment in the spring/summer of 2014. The observed variables in each plant were mean fruit length, mean fruit width, mean fruit weight, number of bunches, number of fruits per bunch, number of fruits, and total weight of fruits, with calculation of the Pearson correlation matrix between them. Sixty eight sample sizes were planned for one greenhouse and 48 for another, with the initial sample size of 10 plants, and the others were obtained by adding five plants. For each planned sample size, 3000 estimates of the Pearson correlation coefficient were obtained through bootstrap re-samplings with replacement. The sample size for each correlation coefficient was determined when the 95% confidence interval amplitude value was less than or equal to 0.4. Obtaining estimates of the Pearson correlation coefficient with high precision is difficult for parameters with a weak linear relation. Accordingly, a larger sample size is necessary to estimate them. Linear relations involving variables dealing with size and number of fruits per plant have less precision. To estimate the coefficient of correlation between productivity variables of cherry tomato, with a confidence interval of 95% equal to 0.4, it is necessary to sample 275 plants in a 250m² greenhouse, and 200 plants in a 200m² greenhouse.

  20. Test-Retest Reliability of Diffusion Tensor Imaging in Huntington's Disease.

    Science.gov (United States)

    Cole, James H; Farmer, Ruth E; Rees, Elin M; Johnson, Hans J; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z

    2014-03-21

    Diffusion tensor imaging (DTI) has shown microstructural abnormalities in patients with Huntington's Disease (HD) and work is underway to characterise how these abnormalities change with disease progression. Using methods that will be applied in longitudinal research, we sought to establish the reliability of DTI in early HD patients and controls. Test-retest reliability, quantified using the intraclass correlation coefficient (ICC), was assessed using region-of-interest (ROI)-based white matter atlas and voxelwise approaches on repeat scan data from 22 participants (10 early HD, 12 controls). T1 data was used to generate further ROIs for analysis in a reduced sample of 18 participants. The results suggest that fractional anisotropy (FA) and other diffusivity metrics are generally highly reliable, with ICCs indicating considerably lower within-subject compared to between-subject variability in both HD patients and controls. Where ICC was low, particularly for the diffusivity measures in the caudate and putamen, this was partly influenced by outliers. The analysis suggests that the specific DTI methods used here are appropriate for cross-sectional research in HD, and give confidence that they can also be applied longitudinally, although this requires further investigation. An important caveat for DTI studies is that test-retest reliability may not be evenly distributed throughout the brain whereby highly anisotropic white matter regions tended to show lower relative within-subject variability than other white or grey matter regions.

  1. Test-retest reliability of speech-evoked auditory brainstem response in healthy children at a low sensation level.

    Science.gov (United States)

    Zakaria, Mohd Normani; Jalaei, Bahram

    2017-11-01

    Auditory brainstem responses evoked by complex stimuli such as speech syllables have been studied in normal subjects and subjects with compromised auditory functions. The stability of speech-evoked auditory brainstem response (speech-ABR) when tested over time has been reported but the literature is limited. The present study was carried out to determine the test-retest reliability of speech-ABR in healthy children at a low sensation level. Seventeen healthy children (6 boys, 11 girls) aged from 5 to 9 years (mean = 6.8 ± 3.3 years) were tested in two sessions separated by a 3-month period. The stimulus used was a 40-ms syllable /da/ presented at 30 dB sensation level. As revealed by pair t-test and intra-class correlation (ICC) analyses, peak latencies, peak amplitudes and composite onset measures of speech-ABR were found to be highly replicable. Compared to other parameters, higher ICC values were noted for peak latencies of speech-ABR. The present study was the first to report the test-retest reliability of speech-ABR recorded at low stimulation levels in healthy children. Due to its good stability, it can be used as an objective indicator for assessing the effectiveness of auditory rehabilitation in hearing-impaired children in future studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. [Characteristics of high resolution diffusion weighted imaging apparent diffusion coefficient histogram and its correlations with cancer stages in patients with nasopharyngeal carcinoma].

    Science.gov (United States)

    Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L

    2017-11-07

    Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).

  3. Knowledge in schizophrenia: The Portuguese version of KAST (Knowledge About Schizophrenia Test) and analysis of social-demographic and clinical factors' influence.

    Science.gov (United States)

    Daltio, C S; Attux, C; Ferraz, M B

    2015-10-01

    Schizophrenia is a complex disorder, and the knowledge about it can have a positive impact. The purpose of this study was to make the translation and cultural adaptation of the Knowledge About Schizophrenia Test (KAST) into Portuguese and determine the influence of clinical and socio-demographic factors on knowledge. The test was applied to 189 caregivers of patients enrolled in Schizophrenia Program of the Federal University of São Paulo, 30 caregivers of clinical patients of the General Outpatient Clinic of the same University, and 30 health professionals. The face and content validity of the test was established. The mean value (SD) obtained with the application of the final version to caregivers of schizophrenic patients was 12.96 (2.45) - maximum 17. Level of knowledge increased considering the following order: caregivers of clinical patients, caregivers of patients with schizophrenia and mental health professionals. The intraclass correlation coefficient (0.592) obtained in the test-retest was statistically significant. An influence of social class, race, gender and education of the caregiver on the test was observed, and the last two factors were more relevant. The KAST translated and adapted into Portuguese is a valid instrument and can be used as an evaluation tool on psychoeducational interventions. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. An alternative to the balance error scoring system: using a low-cost balance board to improve the validity/reliability of sports-related concussion balance testing.

    Science.gov (United States)

    Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J

    2014-05-01

    Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.

  5. Intra- and interrater reliability of the 'lumbar-locked thoracic rotation test' in competitive swimmers ages 10 through 18 years.

    Science.gov (United States)

    Feijen, Stef; Kuppens, Kevin; Tate, Angela; Baert, Isabel; Struyf, Thomas; Struyf, Filip

    2018-04-17

    Measuring thoracic spine mobility can be of interest to competitive swimmers as it has been associated with shoulder girdle function and scapular position in subjects with and without shoulder pain. At present, no reliability data of thoracic spine mobility measurements are available in the swimming population. This study aims to evaluate the within-session intra- and interrater reliability of the "lumbar-locked rotation test" for thoracic spine rotation in competitive swimmers aged 10 to 18 years. This reliability study is part of a larger prospective cohort study investigating potential risk factors for the development of shoulder pain in competitive swimmers. Within-session, intra- and inter-rater reliability. Competitive swimming clubs in Belgium. 21 competitive swimmers. Intra- and inter-rater reliability of the lumbar-locked thoracic rotation test. Intraclass correlation coefficients (ICCs) ranged from 0.91 (95% CI 0.78 to 0.96) to 0.96 (0.89-0.98) for intra-rater reliability. Results for inter-rater reliability ranged from 0.89 (0.72-0.95) to 0.86 (0.65-0.94) respectively for right and left thoracic rotation. Results suggest good to excellent reliability of the lumbar-locked thoracic rotation test, indicating this test can be used reliably in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. A powerful nonparametric method for detecting differentially co-expressed genes: distance correlation screening and edge-count test.

    Science.gov (United States)

    Zhang, Qingyang

    2018-05-16

    Differential co-expression analysis, as a complement of differential expression analysis, offers significant insights into the changes in molecular mechanism of different phenotypes. A prevailing approach to detecting differentially co-expressed genes is to compare Pearson's correlation coefficients in two phenotypes. However, due to the limitations of Pearson's correlation measure, this approach lacks the power to detect nonlinear changes in gene co-expression which is common in gene regulatory networks. In this work, a new nonparametric procedure is proposed to search differentially co-expressed gene pairs in different phenotypes from large-scale data. Our computational pipeline consisted of two main steps, a screening step and a testing step. The screening step is to reduce the search space by filtering out all the independent gene pairs using distance correlation measure. In the testing step, we compare the gene co-expression patterns in different phenotypes by a recently developed edge-count test. Both steps are distribution-free and targeting nonlinear relations. We illustrate the promise of the new approach by analyzing the Cancer Genome Atlas data and the METABRIC data for breast cancer subtypes. Compared with some existing methods, the new method is more powerful in detecting nonlinear type of differential co-expressions. The distance correlation screening can greatly improve computational efficiency, facilitating its application to large data sets.

  7. Experimental test of Bell`s inequalities using angular correlation of compton-scattered annihilation photons

    Energy Technology Data Exchange (ETDEWEB)

    Osuch, S.; Popkiewicz, M.; Szeflinski, Z.; Wilhelmi, Z. [Warsaw Univ., Inst. of Experimental Physics, Warsaw (Poland)

    1995-12-31

    The Bell`s inequality has been experimentally tested using angular correlation of Compton-scattered photons from annihilation of positrons emitted from {sup 22}Na source. The result shows a better agreement with the quantum mechanics predictions rather than with the Bell`s inequality. 7 refs, 5 figs, 1 tab.

  8. Validation of the Brazilian version of the childhood asthma control test (c-ACT).

    Science.gov (United States)

    Oliveira, Suelen G; Sarria, Edgar E; Roncada, Cristian; Stein, Renato T; Pitrez, Paulo M; Mattiello, Rita

    2016-04-01

    Children's perception of their symptoms has proved reliable and relevant to disease management and should be considered when assessing their asthma control. The aim of the study is to validate the Brazilian Portuguese version of the Childhood Asthma Control Test (c-ACT) in children aged 4-11 years. This is a cross-sectional study in children diagnosed with asthma undergoing treatment in a pediatric pulmonology outpatient clinic in Porto Alegre, Brazil. The translation and linguistic adaptation of the instrument were performed in accordance with international recommendations for questionnaire validation. A total of 105 participants were included, aged 4-11 years. all correlations between the total score and items on the questionnaire were significant and obtained values of r ≥ 0.3, and c-ACT means showed statistically significant differences between the GINA categories (P ACT scores than those of uncontrolled asthma group (controlled 22.0 ± 2.9 vs. uncontrolled 16.3 ± 5.3 P ACT scores than those of uncontrolled asthma group (partially controlled 20.0 ± 4.0 vs. uncontrolled 16.3 ± 5.3 P = 0.03). Correlations between the c-ACT total score and spirometry and nitric oxide were poor (r = 0.020; P = 0.866 and r = 0.035; P = 0.753, respectively). Reliability: the α-C coefficient for the c-ACT total score was 0.677 (95%CI 0.573-0763). Sensitivity to change had an effect size of 0.8 and an intraclass correlation coefficient of 0.598. No floor or ceiling effects were observed. The Brazilian version of the Childhood Asthma Control Test proved to be valid and reliable in children aged 4-11 years. © 2015 Wiley Periodicals, Inc.

  9. Laboratory evaluation of an optimised internet-based speech-in-noise test for occupational high-frequency hearing loss screening: Occupational Earcheck.

    Science.gov (United States)

    Sheikh Rashid, Marya; Leensen, Monique C J; de Laat, Jan A P M; Dreschler, Wouter A

    2017-11-01

    The "Occupational Earcheck" (OEC) is a Dutch online self-screening speech-in-noise test developed for the detection of occupational high-frequency hearing loss (HFHL). This study evaluates an optimised version of the test and determines the most appropriate masking noise. The original OEC was improved by homogenisation of the speech material, and shortening the test. A laboratory-based cross-sectional study was performed in which the optimised OEC in five alternative masking noise conditions was evaluated. The study was conducted on 18 normal-hearing (NH) adults, and 15 middle-aged listeners with HFHL. The OEC in a low-pass (LP) filtered stationary background noise (test version LP 3: with a cut-off frequency of 1.6 kHz, and a noise floor of -12 dB) was the most accurate version tested. The test showed a reasonable sensitivity (93%), and specificity (94%) and test reliability (intra-class correlation coefficient: 0.84, mean within-subject standard deviation: 1.5 dB SNR, slope of psychometric function: 13.1%/dB SNR). The improved OEC, with homogenous word material in a LP filtered noise, appears to be suitable for the discrimination between younger NH listeners and older listeners with HFHL. The appropriateness of the OEC for screening purposes in an occupational setting will be studied further.

  10. Development, test-retest reliability, and construct validity of the resistance training skills battery.

    Science.gov (United States)

    Lubans, David R; Smith, Jordan J; Harries, Simon K; Barnett, Lisa M; Faigenbaum, Avery D

    2014-05-01

    The aim of this study was to describe the development and assess test-retest reliability and construct validity of the Resistance Training Skills Battery (RTSB) for adolescents. The RTSB provides an assessment of resistance training skill competency and includes 6 exercises (i.e., body weight squat, push-up, lunge, suspended row, standing overhead press, and front support with chest touches). Scoring for each skill is based on the number of performance criteria successfully demonstrated. An overall resistance training skill quotient (RTSQ) is created by adding participants' scores for the 6 skills. Participants (44 boys and 19 girls, mean age = 14.5 ± 1.2 years) completed the RTSB on 2 occasions separated by 7 days. Participants also completed the following fitness tests, which were used to create a muscular fitness score (MFS): handgrip strength, timed push-up, and standing long jump tests. Intraclass correlation (ICC), paired samples t-tests, and typical error were used to assess test-retest reliability. To assess construct validity, gender and RTSQ were entered into a regression model predicting MFS. The rank order repeatability of the RTSQ was high (ICC = 0.88). The model explained 39% of the variance in MFS (p ≤ 0.001) and RTSQ (r = 0.40, p ≤ 0.001) was a significant predictor. This study has demonstrated the construct validity and test-retest reliability of the RTSB in a sample of adolescents. The RTSB can reliably rank participants in regards to their resistance training competency and has the necessary sensitivity to detect small changes in resistance training skill proficiency.

  11. Correlation among High School Senior Students' Test Anxiety, Academic Performance and Points of University Entrance Exam

    Science.gov (United States)

    Karatas, Hakan; Alci, Bulent; Aydin, Hasan

    2013-01-01

    Test anxiety seems like a benign problem to some people, but it can be potentially serious when it leads to high levels of distress and academic failure. The aim of this study is to define the correlation among high school senior students' test anxiety, academic performance (GPA) and points of university entrance exam (UEE). The study group of…

  12. Increased correlation coefficient between the written test score and tutors’ performance test scores after training of tutors for assessment of medical students during problem-based learning course in Malaysia

    Directory of Open Access Journals (Sweden)

    Heethal Jaiprakash

    2016-03-01

    Full Text Available This paper is aimed at finding if there was a change of correlation between the written test score and tutors’ performance test scores in the assessment of medical students during a problem-based learning (PBL course in Malaysia. This is a cross-sectional observational study, conducted among 264 medical students in two groups from November 2010 to November 2012. The first group’s tutors did not receive tutor training; while the second group’s tutors were trained in the PBL process. Each group was divided into high, middle and low achievers based on their end-of-semester exam scores. PBL scores were taken which included written test scores and tutors’ performance test scores. Pearson correlation coefficient was calculated between the two kinds of scores in each group. The correlation coefficient between the written scores and tutors’ scores in group 1 was 0.099 (p<0.001 and for group 2 was 0.305 (p<0.001. The higher correlation coefficient in the group where tutors received the PBL training reinforces the importance of tutor training before their participation in the PBL course.

  13. Measurement of the area of venous ulcers using two software programs 1

    Science.gov (United States)

    Eberhardt, Thaís Dresch; de Lima, Suzinara Beatriz Soares; Lopes, Luis Felipe Dias; Borges, Eline de Lima; Weiller, Teresinha Heck; da Fonseca, Graziele Gorete Portella

    2016-01-01

    ABSTRACT Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. Results: the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². Conclusion: the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm². PMID:27992028

  14. Feasibility of remote administration of the Fundamentals of Laparoscopic Surgery (FLS) skills test.

    Science.gov (United States)

    Okrainec, Allan; Vassiliou, Melina; Kapoor, Andrew; Pitzul, Kristen; Henao, Oscar; Kaneva, Pepa; Jackson, Timothy; Ritter, E Matt

    2013-11-01

    Fundamentals of Laparoscopic Surgery (FLS) certification testing currently is offered at accredited test centers or at select surgical conferences. Maintaining these test centers requires considerable investment in human and financial resources. Additionally, it can be challenging for individuals outside North America to become FLS certified. The objective of this pilot study was to assess the feasibility of remotely administering and scoring the FLS examination using live videoconferencing compared with standard onsite testing. This parallel mixed-methods study used both FLS scoring data and participant feedback to determine the barriers to feasibility of remote proctoring for the FLS examination. Participants were tested at two accredited FLS testing centers. An official FLS proctor administered and scored the FLS exam remotely while another onsite proctor provided a live score of participants' performance. Participant feedback was collected during testing. Interrater reliabilities of onsite and remote FLS scoring data were compared using intraclass correlation coefficients (ICCs). Participant feedback was analyzed using modified grounded theory to identify themes for barriers to feasibility. The scores of the remote and onsite proctors showed excellent interrater reliability in the total FLS (ICC 0.995, CI [0.985-0.998]). Several barriers led to critical errors in remote scoring, but most were accompanied by a solution incorporated into the study protocol. The most common barrier was the chain of custody for exam accessories. The results of this pilot study suggest that remote administration of the FLS has the potential to decrease costs without altering test-taker scores or exam validity. Further research is required to validate protocols for remote and onsite proctors and to direct execution of these protocols in a controlled environment identical to current FLS test administration.

  15. Psychometric assessment of the Brazilian version of the Male Body Dissatisfaction Scale

    Directory of Open Access Journals (Sweden)

    Pedro Henrique Berbert de Carvalho

    2015-08-01

    Full Text Available Background The study of male body image has increased substantially, but there are few assessment tools available for this population. The Male Body Dissatisfaction Scale (MBDS has been widely used among students to research body image disturbances and eating disorders. However, the psychometric properties of this instrument have not been tested in the Brazilian context.Objectives To explore the psychometric properties (convergent validity, internal consistency, test-retest reliability and factor structure of the Brazilian version of the MBDS.Methods Two-hundred sixty-four undergraduate students were evaluated. Pearson’s correlation was used to test the convergent validity of the MBDS and the Drive for Muscularity Scale, the Swansea Muscularity Attitudes Questionnaire, the Rosenberg Self-Esteem Scale, the Beck Depression Inventory, the Eating Attitudes Test-26, and the Commitment to Exercise Scale. Test-retest reliability was evaluated using t-tests for repeated measures and by calculating the coefficient of intraclass correlation. Exploratory factor analysis was conducted, and Cronbach’s α coefficients were determined. A significance level of 5% was adopted.Results The MBDS had an adequate factor structure, with two factors explaining 52.67% of the total variance. It showed excellent internal consistency (Cronbach’s α between 0.90 and 0.92, a high intraclass correlation coefficient (0.81, and convergent validity with the drive for muscularity, the psychological commitment to exercise, low self-esteem, and eating disorder risk behaviour measures.Discussion The MBDS appears to be a valid and reliable tool for evaluating Brazilian male body image dissatisfaction.

  16. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  17. Thermal Vacuum Test Correlation of A Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytics Model

    Science.gov (United States)

    McKim, Stephen A.

    2016-01-01

    This thesis describes the development and test data validation of the thermal model that is the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented to validate the model are presented. The thermal model was correlated to within plus or minus 3 degrees Centigrade of the thermal vacuum test data, and was found to be relatively insensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed, however, to refine the thermal model to further improve temperature predictions in the upper hemisphere of the propellant tank. Temperatures predictions in this portion were found to be 2-2.5 degrees Centigrade lower than the test data. A road map to apply the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

  18. 40 CFR 86.163-00 - Spot check correlation procedures for vehicles tested using a simulation of the environmental...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Spot check correlation procedures for... Complete Heavy-Duty Vehicles; Test Procedures § 86.163-00 Spot check correlation procedures for vehicles... running change approval, each model year for any manufacturer undergoing the spot checking procedures of...

  19. CORRELATION BETWEEN SEED TESTS AND FIELD EMERGENCE OF TWO MAIZE HYBRIDS (SC704 AND SC500)

    OpenAIRE

    A.A. ALILOO; B. SHOKATI

    2011-01-01

    Early emergence and stand establishment of maize (Zea mays L.) are considered to be the most important yield-contributing factors. The influence of seed vigor on these factors is vital. Therefore, five laboratory tests and field experiment were conducted on basis of a randomized complete block design (RCBD) with five replications in 2011, to evaluate the correlation among the seed vigor tests and field emergence of two maize hybrids (SC704 and SC500). In laboratory tests, differences between ...

  20. Modeling conditional correlations of asset returns

    DEFF Research Database (Denmark)

    Silvennoinen, Annastiina; Teräsvirta, Timo

    2015-01-01

    In this paper we propose a new multivariate GARCH model with time-varying conditional correlation structure. The time-varying conditional correlations change smoothly between two extreme states of constant correlations according to a predetermined or exogenous transition variable. An LM-test is d......In this paper we propose a new multivariate GARCH model with time-varying conditional correlation structure. The time-varying conditional correlations change smoothly between two extreme states of constant correlations according to a predetermined or exogenous transition variable. An LM......-test is derived to test the constancy of correlations and LM- and Wald tests to test the hypothesis of partially constant correlations. Analytical expressions for the test statistics and the required derivatives are provided to make computations feasible. An empirical example based on daily return series of five...

  1. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data.

    Science.gov (United States)

    Hsiao, Yu-Yu; Lai, Mark H C

    2018-01-01

    Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended.

  2. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data

    Directory of Open Access Journals (Sweden)

    Yu-Yu Hsiao

    2018-05-01

    Full Text Available Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b To examine whether unique features of multilevel data, such as intraclass correlation (ICC and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (noninvariance structure of the predictor and/or the outcome is recommended.

  3. Validation of the Inventaire du Milieu Familial Questionnaire (French version of the Infant/Toddler HOME) into the Brazilian Portuguese language.

    Science.gov (United States)

    Sudbrack, Simone; Barbosa, Fernanda P; Mattiello, Rita; Booij, Linda; Estorgato, Geovana R; Dutra, Moisés S; Assunção, Fabiana D de; Nunes, Magda L

    2018-04-22

    To validate the Brazilian Portuguese version of the Family Environment Assessment questionnaire (Inventaire du Milieu Familial). The validation process was carried out in two stages. First, translation and back-translation were performed, and in the second phase, the questionnaire was applied in 72 families of children between 0 and 24 months for the validation process. The tool consists of the following domains: mother's communication ability; behavior; organization of the physical and temporal environment; collection/quantity of toys; maternal attitude of constant attention toward her baby; diversification of stimuli; baby's behavior. The following was performed for the scale validation: 1 - content analysis (judgment); 2 - construct analysis (factorial analysis - Kaiser-Meyer-Olkin, Bartlett, and Pearson's correlation tests); 3 - criterion analysis (calculation of Cronbach's alpha coefficient, intraclass correlations, and split-half correlations). The mean age of the children was 9±6.7 months, and of these, 35 (48.6%) were males. Most correlations between items and domains were significant. In the factorial analysis of the scale, Kaiser-Meyer-Olkin values were 0.76, Bartlett's test showed a p-value<0.001, and correlation between items and domains showed a p-value<0.01. Regarding the validity, Cronbach's alpha was 0.92 (95% CI: 0.89-0.94). The intraclass correlation among the evaluators was 0.97 (0.96-0.98) and split-half correlations, r: 0.60, with p<0.01. The Portuguese version of the Inventaire du Milieu Familial showed good to excellent performance regarding the assessed psychometric properties. Copyright © 2018. Published by Elsevier Editora Ltda.

  4. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs.

    Science.gov (United States)

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent-teacher and 19 mother-father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent-teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother-father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings.

  5. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    Science.gov (United States)

    Stolarova, Margarita; Wolf, Corinna; Rinker, Tanja; Brielmann, Aenne

    2014-01-01

    This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire developed for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent–teacher and 19 mother–father pairs) collected for two-year-old children (12 bilingual) are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC). Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent–teacher ratings of children's early vocabulary can achieve agreement and correlation comparable to those of mother–father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters' agreement. We conclude that future reports of agreement, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings. PMID:24994985

  6. Increased correlation coefficient between the written test score and tutors' performance test scores after training of tutors for assessment of medical students during problem-based learning course in Malaysia.

    Science.gov (United States)

    Jaiprakash, Heethal; Min, Aung Ko Ko; Ghosh, Sarmishtha

    2016-03-01

    This paper is aimed at finding if there was a change of correlation between the written test score and tutors' performance test scores in the assessment of medical students during a problem-based learning (PBL) course in Malaysia. This is a cross-sectional observational study, conducted among 264 medical students in two groups from November 2010 to November 2012. The first group's tutors did not receive tutor training; while the second group's tutors were trained in the PBL process. Each group was divided into high, middle and low achievers based on their end-of-semester exam scores. PBL scores were taken which included written test scores and tutors' performance test scores. Pearson correlation coefficient was calculated between the two kinds of scores in each group. The correlation coefficient between the written scores and tutors' scores in group 1 was 0.099 (pcorrelation coefficient in the group where tutors received the PBL training reinforces the importance of tutor training before their participation in the PBL course.

  7. Correlation of same-visit HbA1c test with laboratory-based measurements: A MetroNet study

    Directory of Open Access Journals (Sweden)

    West Patricia A

    2005-07-01

    Full Text Available Abstract Background Glycated hemoglobin (HbA1c results vary by analytical method. Use of same-visit HbA1c testing methodology holds the promise of more efficient patient care, and improved diabetes management. Our objective was to test the feasibility of introducing a same-visit HbA1c methodology into busy family practice centers (FPC and to calculate the correlation between the same-visit HbA1c test and the laboratory method that the clinical site was currently using for HbA1c testing. Methods Consecutive diabetic patients 18 years of age and older having blood samples drawn for routine laboratory analysis of HbA1c were asked to provide a capillary blood sample for same-visit testing with the BIO-RAD Micromat II. We compared the results of the same-visit test to three different laboratory methods (one FPC used two different laboratories. Results 147 paired samples were available for analysis (73 from one FPC; 74 from the other. The Pearson correlation of Micromat II and ion-exchange HPLC was 0.713 (p Conclusion For each of the laboratory methods, the correlation coefficient was lower than the 0.96 reported by the manufacturer. This might be due to variability introduced by the multiple users of the Micromat II machine. The mean HbA1c results were also consistently lower than those obtained from laboratory analysis. Additionally, the amount of dedicated time required to perform the assay may limit its usefulness in a busy clinical practice. Before introducing a same-visit HbA1c methodology, clinicians should compare the rapid results to their current method of analysis.

  8. Interrater reliability assessment using the Test of Gross Motor Development-2.

    Science.gov (United States)

    Barnett, Lisa M; Minto, Christine; Lander, Natalie; Hardy, Louise L

    2014-11-01

    The aim was to examine interrater reliability of the object control subtest from the Test of Gross Motor Development-2 by live observation in a school field setting. Reliability Study--cross sectional. Raters were rated on their ability to agree on (1) the raw total for the six object control skills; (2) each skill performance and (3) the skill components. Agreement for the object control subtest and the individual skills was assessed by an intraclass correlation (ICC) and a kappa statistic assessed for skill component agreement. A total of 37 children (65% girls) aged 4-8 years (M = 6.2, SD = 0.8) were assessed in six skills by two raters; equating to 222 skill tests. Interrater reliability was excellent for the object control subset (ICC = 0.93), and for individual skills, highest for the dribble (ICC = 0.94) followed by strike (ICC = 0.85), overhand throw (ICC = 0.84), underhand roll (ICC = 0.82), kick (ICC = 0.80) and the catch (ICC = 0.71). The strike and the throw had more components with less agreement. Even though the overall subtest score and individual skill agreement was good, some skill components had lower agreement, suggesting these may be more problematic to assess. This may mean some skill components need to be specified differently in order to improve component reliability. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  9. Quality of prenatal care questionnaire: instrument development and testing.

    Science.gov (United States)

    Heaman, Maureen I; Sword, Wendy A; Akhtar-Danesh, Noori; Bradford, Amanda; Tough, Suzanne; Janssen, Patricia A; Young, David C; Kingston, Dawn A; Hutton, Eileen K; Helewa, Michael E

    2014-06-03

    Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women's ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the "Support and Respect" subscale of the QPCQ and the "Respectfulness/Emotional Support" subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach's alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women's ratings of their quality of prenatal care did not change as a result of giving birth or between the early postpartum

  10. Quality of prenatal care questionnaire: instrument development and testing

    Science.gov (United States)

    2014-01-01

    Background Utilization indices exist to measure quantity of prenatal care, but currently there is no published instrument to assess quality of prenatal care. The purpose of this study was to develop and test a new instrument, the Quality of Prenatal Care Questionnaire (QPCQ). Methods Data for this instrument development study were collected in five Canadian cities. Items for the QPCQ were generated through interviews with 40 pregnant women and 40 health care providers and a review of prenatal care guidelines, followed by assessment of content validity and rating of importance of items. The preliminary 100-item QPCQ was administered to 422 postpartum women to conduct item reduction using exploratory factor analysis. The final 46-item version of the QPCQ was then administered to another 422 postpartum women to establish its construct validity, and internal consistency and test-retest reliability. Results Exploratory factor analysis reduced the QPCQ to 46 items, factored into 6 subscales, which subsequently were validated by confirmatory factor analysis. Construct validity was also demonstrated using a hypothesis testing approach; there was a significant positive association between women’s ratings of the quality of prenatal care and their satisfaction with care (r = 0.81). Convergent validity was demonstrated by a significant positive correlation (r = 0.63) between the “Support and Respect” subscale of the QPCQ and the “Respectfulness/Emotional Support” subscale of the Prenatal Interpersonal Processes of Care instrument. The overall QPCQ had acceptable internal consistency reliability (Cronbach’s alpha = 0.96), as did each of the subscales. The test-retest reliability result (Intra-class correlation coefficient = 0.88) indicated stability of the instrument on repeat administration approximately one week later. Temporal stability testing confirmed that women’s ratings of their quality of prenatal care did not change as a result of giving

  11. Testing the Psychometric Properties of a Chinese Version of the Level of Expressed Emotion Scale

    Directory of Open Access Journals (Sweden)

    Wai Tong Chien

    2014-01-01

    Full Text Available This study tested the psychometric properties of a Chinese version of the level of expressed emotion scale in Hong Kong Chinese patients with severe mental illness and their family caregivers. First, the semantic equivalence with the original English version and test-retest reliability at 2-week interval of the Chinese version was examined. After that, the reproducibility, construct validity, and internal consistency of the Chinese version were tested. The Chinese version indicated good semantic equivalence with the English version (kappa values = 0.76–0.95 and ICC = 0.81–0.92, test-retest reliability (r = 0.89–0.95, P<0.01, and internal consistency (Cronbach’s α = 0.86–0.92. Among 262 patients with severe mental illness and their caregivers, the 50-item Chinese version had substantial loadings on one of the four factors identified (intrusiveness/hostility, attitude towards patient, tolerance, and emotional involvement, accounting for 71.8% of the total variance of expressed emotion. In confirmatory factor analysis, the identified four-factor model showed the best fit based on all fit indices (χ2/df = 1.93, P=0.75; AGFI = 0.96; TLI = 1.02; RMSEA = 0.031; WRMR = 0.78 to the collected data. The four-factor Chinese version also indicated a good concurrent validity with significant correlations with family functioning (r = −0.54 and family burden (r = 0.49 and a satisfactory reproducibility over six months (intraclass correlation coefficient of 0.90. The mean scores of the overall and subscale of the Chinese version in patients with unipolar disorder were higher than in other illness groups (schizophrenia, psychotic disorders, and bipolar disorder; P<0.01. The Chinese version demonstrates sound psychometric properties to measure families’ expressed emotion in Chinese patients with severe mental illness, which are found varied across countries.

  12. Development, reliability, and validity testing of Toddler NutriSTEP: a nutrition risk screening questionnaire for children 18-35 months of age.

    Science.gov (United States)

    Randall Simpson, Janis; Gumbley, Jillian; Whyte, Kylie; Lac, Jane; Morra, Crystal; Rysdale, Lee; Turfryer, Mary; McGibbon, Kim; Beyers, Joanne; Keller, Heather

    2015-09-01

    Nutrition is vital for optimal growth and development of young children. Nutrition risk screening can facilitate early intervention when followed by nutritional assessment and treatment. NutriSTEP (Nutrition Screening Tool for Every Preschooler) is a valid and reliable nutrition risk screening questionnaire for preschoolers (aged 3-5 years). A need was identified for a similar questionnaire for toddlers (aged 18-35 months). The purpose was to develop a reliable and valid Toddler NutriSTEP. Toddler NutriSTEP was developed in 4 phases. Content and face validity were determined with a literature review, parent focus groups (n = 6; 48 participants), and experts (n = 13) (phase A). A draft questionnaire was refined with key intercept interviews of 107 parents/caregivers (phase B). Test-retest reliability (phase C), based on intra-class correlations (ICC), Kappa (κ) statistics, and Wilcoxon tests was assessed with 133 parents/caregivers. Criterion validity (phase D) was assessed using Receiver Operating Characteristic (ROC) curves by comparing scores on the Toddler NutriSTEP to a comprehensive nutritional assessment of 200 toddlers with a registered dietitian (RD). The Toddler NutriSTEP was reliable between 2 administrations (ICC = 0.951, F = 20.53, p Toddler NutriSTEP were correlated (r = 0.67, p Toddler NutriSTEP questionnaire is both reliable and valid for screening for nutritional risk in toddlers.

  13. Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests

    OpenAIRE

    Naseri, Mandana; Khayat, Akbar; Zamaheni, Sara; Shojaeian, Shiva

    2017-01-01

    Introduction: The purpose of this study was to assess the accuracy of sensibility tests by correlating it with histologic pulp condition. Methods and Materials: Assessment of clinical signs and symptoms were performed on 65 permanent teeth that were scheduled to be extracted for periodontal, prosthodontic or orthodontic reasons. The normal pulp and reversible pulpitis were considered as treatable tooth conditions while irreversible pulpitis and necrosis were considered as untreatable conditio...

  14. Rating scale for psychogenic nonepileptic seizures: scale development and clinimetric testing.

    Science.gov (United States)

    Cianci, Vittoria; Ferlazzo, Edoardo; Condino, Francesca; Mauvais, Hélène Somma; Farnarier, Guy; Labate, Angelo; Latella, Maria Adele; Gasparini, Sara; Branca, Damiano; Pucci, Franco; Vazzana, Francesco; Gambardella, Antonio; Aguglia, Umberto

    2011-06-01

    Our aim was to develop a clinimetric scale evaluating motor phenomena, associated features, and severity of psychogenic nonepileptic seizures (PNES). Sixty video/EEG-recorded PNES induced by suggestion maneuvers were evaluated. We examined the relationship between results from this scale and results from the Clinical Global Impression (CGI) scale to validate this technique. Interrater reliabilities of the PNES scale for three raters were analyzed using the AC1 statistic, Kendall's coefficient of concordance (KCC), and intraclass correlation coefficients (ICCs). The relationship between the CGI and PNES scales was evaluated with Spearman correlations. The AC1 statistic demonstrated good interrater reliability for each phenomenon analyzed (tremor/oscillation, tonic; clonic/jerking, hypermotor/agitation, atonic/akinetic, automatisms, associated features). KCC and the ICC showed moderate interrater agreement for phenomenology, associated phenomena, and total PNES scores. Spearman's correlation of mean CGI score with mean total PNES score was 0.69 (Pscale described here accurately evaluates the phenomenology of PNES and could be used to assess and compare subgroups of patients with PNES. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Development of the Modified Four Square Step Test and its reliability and validity in people with stroke.

    Science.gov (United States)

    Roos, Margaret A; Reisman, Darcy S; Hicks, Gregory; Rose, William; Rudolph, Katherine S

    2016-01-01

    Adults with stroke have difficulty avoiding obstacles when walking, especially when a time constraint is imposed. The Four Square Step Test (FSST) evaluates dynamic balance by requiring individuals to step over canes in multiple directions while being timed, but many people with stroke are unable to complete it. The purposes of this study were to (1) modify the FSST by replacing the canes with tape so that more persons with stroke could successfully complete the test and (2) examine the reliability and validity of the modified version. Fifty-five subjects completed the Modified FSST (mFSST) by stepping over tape in all four directions while being timed. The mFSST resulted in significantly greater numbers of subjects completing the test than the FSST (39/55 [71%] and 33/55 [60%], respectively) (p < 0.04). The test-retest, intrarater, and interrater reliability of the mFSST were excellent (intraclass correlation coefficient ranges: 0.81-0.99). Construct and concurrent validity of the mFSST were also established. The minimal detectable change was 6.73 s. The mFSST, an ideal measure of dynamic balance, can identify progress in people with stroke in varied settings and can be completed by a wide range of people with stroke in approximately 5 min with the use of minimal equipment (tape, stop watch).

  16. Validity of the Nintendo Wii® balance board for the assessment of standing balance in Parkinson's disease.

    Science.gov (United States)

    Holmes, Jeffrey D; Jenkins, Mary E; Johnson, Andrew M; Hunt, Michael A; Clark, Ross A

    2013-04-01

    Impaired postural stability places individuals with Parkinson's at an increased risk for falls. Given the high incidence of fall-related injuries within this population, ongoing assessment of postural stability is important. To evaluate the validity of the Nintendo Wii(®) balance board as a measurement tool for the assessment of postural stability in individuals with Parkinson's. Twenty individuals with Parkinson's participated. Subjects completed testing on two balance tasks with eyes open and closed on a Wii(®) balance board and biomechanical force platform. Bland-Altman plots and a two-way, random-effects, single measure intraclass correlation coefficient model were used to assess concurrent validity of centre-of-pressure data. Concurrent validity was demonstrated to be excellent across balance tasks (intraclass correlation coefficients = 0.96, 0.98, 0.92, 0.94). This study suggests that the Wii(®) balance board is a valid tool for the quantification of postural stability among individuals with Parkinson's.

  17. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  18. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    Science.gov (United States)

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  19. Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

    Science.gov (United States)

    Mason, Brian H.; Sleight, David W.; Grenoble, Ray

    2015-01-01

    The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

  20. The Persian Version of the "Life Satisfaction Scale": Construct Validity and Test-Re-Test Reliability among Iranian Older Adults.

    Science.gov (United States)

    Moghadam, Manije; Salavati, Mahyar; Sahaf, Robab; Rassouli, Maryam; Moghadam, Mojgan; Kamrani, Ahmad Ali Akbari

    2018-03-01

    After forward-backward translation, the LSS was administered to 334 Persian speaking, cognitively healthy elderly aged 60 years and over recruited through convenience sampling. To analyze the validity of the model's constructs and the relationships between the constructs, a confirmatory factor analysis followed by PLS analysis was performed. The Construct validity was further investigated by calculating the correlations between the LSS and the "Short Form Health Survey" (SF-36) subscales measuring similar and dissimilar constructs. The LSS was re-administered to 50 participants a month later to assess the reliability. For the eight-factor model of the life satisfaction construct, adequate goodness of fit between the hypothesized model and the model derived from the sample data was attained (positive and statistically significant beta coefficients, good R-squares and acceptable GoF). Construct validity was supported by convergent and discriminant validity, and correlations between the LSS and SF-36 subscales. Minimum Intraclass Correlation Coefficient level of 0.60 was exceeded by all subscales. Minimum level of reliability indices (Cronbach's α, composite reliability and indicator reliability) was exceeded by all subscales. The Persian-version of the Life Satisfaction Scale is a reliable and valid instrument, with psychometric properties which are consistent with the original version.

  1. CORRELATION OF LOW BACK PAIN WITH BODY MASS INDEX, FUNCTIONAL REACH TEST AMONG FEMALE NURSING PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Shameela .T .V

    2015-12-01

    Full Text Available Background: Among health care workers the highest level of work related back injuries are more affected in nurses. There were many studies done to assess low back pain by using different tools. So this study aimed to identify the prevalence low back pain disability among female nursing professionals and the association between BMI, functional reach test and low back pain, so that a better tool can be used during the clinical examination for the betterment of the patient. The objective of the study is to identify the prevalence of low back pain disability, the association of Low Back Pain(LBP with BMI and functional reach test among female nursing professionals. Methods: A total of 256 subjects were assessed for disability due to back pain using OswestryLBP Disability Questionnaire and the prevalence of disability was determined. The sit and reach test, forward reach test and their BMI were calculated for those who had a disability score of 20 and above (n=87. Results: Data was analyzed using Pearson’s correlation.The study result showed a significant correlation (p=0.03 of sit and reach test with low back pain disability scores. There was a negative correlationseen among BMI and LBP disability score forward reach test and LBP disability score, and BMI and no low back pain disability score. Conclusion: The prevalence of LBP disability among nursing professionals was 33.9%. This study suggest that sit and reach test can be used as an indicator of low back pain. Whereas BMI and forward reach test do not indicate low back pain.

  2. Development of a comprehensive performance-testing protocol for competitive surfers.

    Science.gov (United States)

    Sheppard, Jeremy M; Nimphius, Sophia; Haff, Greg G; Tran, Tai T; Spiteri, Tania; Brooks, Hedda; Slater, Gary; Newton, Robert U

    2013-09-01

    Appropriate and valid testing protocols for evaluating the physical performances of surfing athletes are not well refined. The purpose of this project was to develop, refine, and evaluate a testing protocol for use with elite surfers, including measures of anthropometry, strength and power, and endurance. After pilot testing and consultation with athletes, coaches, and sport scientists, a specific suite of tests was developed. Forty-four competitive junior surfers (16.2 ± 1.3 y, 166.3 ± 7.3 cm, 57.9 ± 8.5 kg) participated in this study involving a within-day repeated-measures analysis, using an elite junior group of 22 international competitors (EJG), to establish reliability of the measures. To reflect validity of the testing measures, a comparison of performance results was then undertaken between the EJG and an age-matched competitive junior group of 22 nationally competitive surfers (CJG). Percent typical error of measurement (%TEM) for primary variables gained from the assessments ranged from 1.1% to 3.0%, with intraclass correlation coefficients ranging from .96 to .99. One-way analysis of variance revealed that the EJG had lower skinfolds (P = .005, d = 0.9) than the CJG, despite no difference in stature (P = .102) or body mass (P = .827). The EJG were faster in 15-m sprint-paddle velocity (P < .001, d = 1.3) and had higher lower-body isometric peak force (P = .04, d = 0.7) and superior endurance-paddling velocity (P = .008, d = 0.9). The relatively low %TEM of these tests in this population allows for high sensitivity to detect change. The results of this study suggest that competitively superior junior surfers are leaner and possess superior strength, paddling power, and paddling endurance.

  3. Reliability and number of trials of Y Balance Test in adolescent athletes.

    Science.gov (United States)

    Linek, Pawel; Sikora, Damian; Wolny, Tomasz; Saulicz, Edward

    2017-10-01

    The Star Excursion Balance Test (SEBT) is commonly used to evaluate dynamic equilibrium. The Y Balance Test (Y-BT) is a shortened version of the SEBT where a Y- Balance Kit is commonly used. To date, research concerning the protocol and reliability of the SEBT and Y-BT has been conducted only for adults. The aim of the study was to assess the protocol (the necessary number of trials to stabilize the results) and reliability of the Y-BT in adolescent athletes. One-way repeated-measures analysis of variance (ANOVA) and reliability study. The sample of 38 athletes (mean age: 15.6 years) was selected from a football club. A Y-Balance test kit was applied for the evaluation of dynamic balance. The analysis used the values normalized to the relative length of the lower limbs. After six attempts, three consecutive ones achieved stability for all directions and both extremities (p > 0.05). The intraclass correlation coefficient (ICC 3,1 ), standard error of measurement and minimal detectable change values for the three attempts ranged from 0.57 to 0.82, from 3 to less than 6% and from 7.68 to 13.7%, respectively. In the study of adolescent dynamic equilibrium using the Y-BT, it is recommended to perform nine attempts (including six trial attempts and three measurements). In order to increase reliability it is recommended that the average of the three measured attempts is analysed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Reliability and validity of lumbar and abdominal trunk muscle endurance tests in office workers with nonspecific subacute low back pain.

    Science.gov (United States)

    del Pozo-Cruz, Borja; Mocholi, Miguel H; del Pozo-Cruz, Jesus; Parraca, Jose A; Adsuar, Jose C; Gusi, Narcis

    2014-01-01

    Despite the widespread use of trunk endurance tests, the reliability and validity of these tests in office workers with subacute nonspecific low back pain are unknown. This cross-sectional study involved 190 subjects: 30 men and 42 women without low back pain and 47 men and 71 women with low back pain. All subjects underwent timed prone and supine isometric lumbar and abdominal trunk endurance tests that were performed until subjective fatigue occurred. All subjects also completed the Roland Morris and Oswestry self-reported disability questionnaires. A test-retest study (7 days) was conducted with 31 participants with low back pain from the study. For the abdominal trunk endurance test, males and females with low back pain had mean (SD) values of 62.06 (36.87) and 46.06 (29.28) seconds, respectively, both significantly lower than the asymptomatic workers. For the lumbar test, males and females with low back pain had mean (SD) values of 79.57 (30.66) and 75.49 (28.97) seconds, respectively, again, both significantly lower than the asymptomatic workers. The intraclass correlation coefficients of both tests exceeded 0.90 and the Kappa indices were excellent for both men and women. Receiver-operating curve analyses revealed areas under the curve very close to or exceeding 0.70 for both men and women for both tests. The lumbar and abdominal trunk muscle endurance tests appeared to be reliable and valid measures in office workers with subacute low back pain.

  5. Developing a Danish version of the "Impact on Participation and Autonomy Questionnaire".

    Science.gov (United States)

    Ghaziani, Emma; Krogh, Anne Grethe; Lund, Hans

    2013-05-01

    To translate the "Impact on Participation and Autonomy Questionnaire" into Danish (IPAQ-DK), and estimate its internal consistency and test-retest reliability in order to promote participation-based interventions and research. Translation and two successive reliability assessments through test-retest. 137 adults with varying degrees of impairment; of these, 67 participated in the final reliability assessment. The translation followed guidelines set forth by the "European Group for Quality of Life Assessment and Health Measurement". Internal consistency for subscales was estimated by Chronbach's alpha. Weighted kappa coefficients and intraclass correlation coefficients were calculated to assess the test-retest reliability at item and subscale level, respectively. A preliminary reliability assessment revealed residual issues regarding the translation and cultural adaptation of the instrument. The revised version (IPAQ-DK) was subsequently subjected to a similar assessment demonstrating Chronbach's alpha values from 0.698 to 0.817. Weighted kappa ranged from 0.370 to 0.880; 78% of these values were higher than 0.600. The intraclass correlation coefficient covered values from 0.701 to 0.818. IPAQ-DK is a useful instrument for identifying person-perceived participation restrictions and satisfaction with participation. Further studies of IPAQ-DK's floor/ceiling effects and responsiveness to change are recommended, and whether there is a need for further linguistic improvement of certain items.

  6. Does the COPD assessment test (CAT(TM)) questionnaire produce similar results when self- or interviewer administered?

    Science.gov (United States)

    Agusti, A; Soler-Cataluña, J J; Molina, J; Morejon, E; Garcia-Losa, M; Roset, M; Badia, X

    2015-10-01

    The COPD assessment test (CAT) is a questionnaire that assesses the impact of chronic obstructive pulmonary disease (COPD) on health status, but some patients have difficulties filling it up by themselves. We examined whether the mode of administration of the Spanish version of CAT (self vs. interviewer) influences its scores and/or psychometric properties. Observational, prospective study in 49 Spanish centers that includes clinically stable COPD patients (n = 153) and patients hospitalized because of an exacerbation (ECOPD; n = 224). The CAT was self-administered (CAT-SA) or administered by an interviewer (CAT-IA) based on the investigator judgment of the patient's capacity. To assess convergent validity, the Saint George's Respiratory Disease Questionnaire (SGRQ) and the London Chest Activity of Daily Living (LCADL) instrument were also administered. Psychometric properties were compared across modes of administration. A total of 118 patients (31 %) completed the CAT-SA and 259 (69 %) CAT-IA. Multiple regression analysis showed that mode of administration did not affect CAT scores. The CAT showed excellent psychometric properties in both modes of administration. Internal consistency coefficients (Cronbach's alpha) were high (0.86 for CAT-SA and 0.85 for CAT-IA) as was test-retest reliability (intraclass correlation coefficients of 0.83 for CAT-SA and CAT-IA). Correlations with SGRQ and LCADL were moderate to strong both in CAT-SA and CAT-IA, indicating good convergent validity. Similar results were observed when testing longitudinal validity. The mode of administration does not influence CAT scores or its psychometric properties. Hence, both modes of administration can be used in clinical practice depending on the physician judgment of patient's capacity.

  7. [Correlation between clinical characteristics and mycological tests in the vulvovaginitis by Candida].

    Science.gov (United States)

    Buitrón García, Rafael; Bonifaz, Alexandro; Amancio Chassin, Octavio; Basurto Kuba, Erich; Araiza, Javier; Romero Cabello, Raúl

    2007-02-01

    Vulvovaginitis caused by Candida sp is one of the most frequent infections. To culture and to identify the fungi related to clinical manifestations of patients based on a suspected diagnosis of vulvovaginal candidiasis. A prospective, transversal and comparative study was performed on 181 women older than 18 years with vulvovaginitis by Candida sp. A correlation was made between the clinical characteristics of this entity and mycological tests such as direct examination and cultures. The direct exam or fresh vaginal exam and cervical sample was positive for the different microscopic forms of Candida (blastoconidia, pseudohyphye or pseudomycelia) in 60.8% (110 women); at the same time that cultures were positive for Candida sp in 51.9% (94 patients). The direct examination and the cultures of vaginal and cervical exudate are mandatory tests for diagnosis of Candida sp in women with vulvovaginitis.

  8. Evaluating the validity and reliability of the V-scale instrument (Turkish version) used to determine nurses' attitudes towards vital sign monitoring.

    Science.gov (United States)

    Ertuğ, Nurcan

    2018-06-01

    The aim of this study was to determine the validity and reliability of the Turkish version of the V-scale, which measures nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. This validity and reliability study was conducted at a tertiary hospital in Ankara, Turkey, in 2016. A total of 169 ward nurses participated in the study. Exploratory factor analysis, Cronbach's alpha coefficient, and the intraclass correlation coefficient were used to determine the validity and reliability of the scale. A 5-factor, 16-item scale explained 60.823% of the total variance according to the validity analysis. Our version matched the original scale in terms of the number of items and factor structure. Cronbach's alpha coefficient of the Turkish version of the V-scale was 0.764. The test-retest reliability results were 0.855 for the overall intraclass correlation coefficient, and the t-test result was P > 0.05. The V-scale is a reliable and valid instrument to measure Turkish nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. © 2018 John Wiley & Sons Australia, Ltd.

  9. Total and regional fat distribution is strongly influenced by genetic factors in young and elderly twins

    DEFF Research Database (Denmark)

    Malis, Charlotte; Rasmussen, Eva L; Poulsen, Pernille

    2005-01-01

    was to estimate the heritability (h(2)) of total and regional fat distribution in young and elderly Danish twins. RESEARCH METHODS AND PROCEDURES: Monozygotic (108) and dizygotic (88) twins in two age groups (25 to 32 and 58 to 66 years) underwent anthropometric measurements and DXA scans. Intraclass correlations...... and etiologic components of variance were estimated for total and regional fat percentages using biometric modeling. RESULTS: The intraclass correlations demonstrated higher correlations for all fat percentages among monozygotic twins as compared with dizygotic twins. The biometric modeling revealed a major...

  10. Test-retest reliability and agreement of the Satisfaction with the Assistive Technology Services (SATS) instrument in two Nordic countries.

    Science.gov (United States)

    Sund, Terje; Iwarsson, Susanne; Anttila, Heidi; Helle, Tina; Brandt, Ase

    2014-07-01

    The purpose of this study was to investigate test-retest reliability, agreement, internal consistency, and floor- and ceiling effects of the Danish and Finnish versions of the Satisfaction with the Assistive Technology Services (SATS) instrument among adult users of powered wheelchairs (PWCs) or powered scooters (scooters). Test-retest design, two telephone interviews 7-18 days apart of 40 informants, with mean age of 67.5 (SD 13.09) years in the Danish; and 54 informants with mean age of 55.6 (SD 12.09) years in the Finnish sample. The intra-class correlation coefficient varied between 0.57 and 0.93 for items in the Danish and between 0.41 and 0.93 in the Finnish sample. The percentage agreement varied between 54.2 and 79.5 for items in the Danish and between 69.2 and 81.1 in the Finnish sample, while the Cronbach's alpha values varied between 0.87 and 0.96 in the two samples. A ceiling effect was found in all items of both samples. This study indicates that the SATS may be reliably administered for telephone interviews among adult PWC and scooter users, and give information about aspects of the service delivery process for quality development improvement purposes. Further psychometric testing of the SATS is required.

  11. The test-retest reliability of anatomical co-ordinate axes definition for the quantification of lower extremity kinematics during running.

    Science.gov (United States)

    Sinclair, Jonathan; Taylor, Paul John; Greenhalgh, Andrew; Edmundson, Christopher James; Brooks, Darrell; Hobbs, Sarah Jane

    2012-12-01

    Three-dimensional (3-D) kinematic analyses are used widely in both sport and clinical examinations. However, this procedure depends on reliable palpation of anatomical landmarks and mal-positioning of markers between sessions may result in improperly defined segment co-ordinate system axes which will produce in-consistent joint rotations. This had led some to question the efficacy of this technique. The aim of the current investigation was to assess the reliability of the anatomical frame definition when quantifying 3-D kinematics of the lower extremities during running. Ten participants completed five successful running trials at 4.0 m·s(-1) ± 5%. 3-D angular joint kinematics parameters from the hip, knee and ankle were collected using an eight camera motion analysis system. Two static calibration trials were captured. The first (test) was conducted prior to the running trials following which anatomical landmarks were removed. The second was obtained following completion of the running trials where anatomical landmarks were re-positioned (retest). Paired samples t-tests were used to compare 3-D kinematic parameters quantified using the two static trials, and intraclass correlations were employed to examine the similarities between the sagittal, coronal and transverse plane waveforms. The results indicate that no significant (p>0.05) differences were found between test and retest 3-D kinematic parameters and strong (R(2)≥0.87) correlations were observed between test and retest waveforms. Based on the results obtained from this investigation, it appears that the anatomical co-ordinate axes of the lower extremities can be defined reliably thus confirming the efficacy of studies using this technique.

  12. In vitro burn model illustrating heat conduction patterns using compressed thermal papers.

    Science.gov (United States)

    Lee, Jun Yong; Jung, Sung-No; Kwon, Ho

    2015-01-01

    To date, heat conduction from heat sources to tissue has been estimated by complex mathematical modeling. In the present study, we developed an intuitive in vitro skin burn model that illustrates heat conduction patterns inside the skin. This was composed of tightly compressed thermal papers with compression frames. Heat flow through the model left a trace by changing the color of thermal papers. These were digitized and three-dimensionally reconstituted to reproduce the heat conduction patterns in the skin. For standardization, we validated K91HG-CE thermal paper using a printout test and bivariate correlation analysis. We measured the papers' physical properties and calculated the estimated depth of heat conduction using Fourier's equation. Through contact burns of 5, 10, 15, 20, and 30 seconds on porcine skin and our burn model using a heated brass comb, and comparing the burn wound and heat conduction trace, we validated our model. The heat conduction pattern correlation analysis (intraclass correlation coefficient: 0.846, p < 0.001) and the heat conduction depth correlation analysis (intraclass correlation coefficient: 0.93, p < 0.001) showed statistically significant high correlations between the porcine burn wound and our model. Our model showed good correlation with porcine skin burn injury and replicated its heat conduction patterns. © 2014 by the Wound Healing Society.

  13. Confiabilidade teste-reteste de aspectos da rede social no Estudo Pró-Saúde Test-retest reliability of measures of social network in the "Pró-Saúde" Study

    Directory of Open Access Journals (Sweden)

    Rosane Harter Griep

    2003-06-01

    Full Text Available OBJETIVO: Avaliar os níveis de confiabilidade teste-reteste de informações relativas à rede social no Estudo Pró-saúde. MÉTODOS: Foi estimada a confiabilidade pelo estudo teste-reteste por meio de questionário multidimensional aplicado a uma coorte de trabalhadores de uma universidade. O mesmo questionário foi preenchido duas vezes por 192 funcionários não efetivos da universidade, com duas semanas de intervalo entre as aplicações. A concordância foi estimada pela estatística Kappa (variáveis categóricas, estatística Kappa ponderado e modelos log-lineares (variáveis ordinais, e coeficiente de correlação intraclasse (variáveis discretas. RESULTADOS: As medidas de concordância situaram-se acima de 0,70 para a maioria das variáveis. Estratificando-se as informações segundo gênero, idade e escolaridade, observou-se que a confiabilidade não apresentou padrão consistente de variabilidade. A aplicação de modelos log-lineares indicou que, para as variáveis ordinais do estudo, o modelo de melhor ajuste foi o de "concordância diagonal mais associação linear por linear". CONCLUSÕES: Os altos níveis de confiabilidade estimados permitem concluir que o processo de aferição dos itens sobre rede social foi adequado para as características investigadas. Estudos de validação em andamento complementarão a avaliação da qualidade dessas informações.OBJECTIVE: To evaluate test-retest reliability of social network-related information of the" Pró-Saúde" study. METHODS: A test-retest reliability study was conducted using a multidimensional questionnaire applied to a cohort of university employees. The same questionnaire was filled out twice by 192 non-permanent employees with two weeks apart. Agreement was estimated using kappa statistics (categorical variables, weighted kappa statistics, log-linear models (ordinal variables, and intraclass correlation coefficient (discrete variables. RESULTS: Estimates of reliability

  14. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy.

    Science.gov (United States)

    Van Vulpen, L F; De Groot, S; Becher, J G; De Wolf, G S; Dallmeijer, A J

    2013-12-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring lower-limb strength with handheld dynamometry (HHD) and dynamic ankle plantar flexor strength with the standing heel-rise (SH) test in 3-10 year aged children with CP. Test-retest design. Rehabilitation centre, special needs school for children with disabilities, and university medical centre. Knee extensor, hip abductor and calf muscle strength was assessed in 20 ambulatory children with spastic CP (3-5 years [N.=10] and 6-10 years [N.=10]) on two test occasions. Intraclass correlation coefficients (ICC) and Smallest Detectable Differences (SDD) were calculated to determine the optimal test design for detecting changes in strength. All isometric strength tests had acceptable SDDs (9-30%), when taking the mean values of 2-3 test occasions (separate days) and 2-3 repetitions. The one-leg SH test had large SDDs (40-128% for younger group, 23-48% for older group). Isometric strength (improvements) can only be measured reliably with HHD in young children with CP when the average values over at least 2 test occasions are taken. Reliability of the SH test is not sufficient for measuring individual changes in dynamic muscle strength in the younger children. Results of this study can be used to determine the optimal number of test occasions and repetitions for reliable HHD measurements depending on expected changes, muscle group and age in 3-10 year old children with CP.

  15. Evaluating the test-retest reliability of symptom indices associated with the ImPACT post-concussion symptom scale (PCSS).

    Science.gov (United States)

    Merritt, Victoria C; Bradson, Megan L; Meyer, Jessica E; Arnett, Peter A

    2018-05-01

    The Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a commonly used tool in sports concussion assessment. While test-retest reliabilities have been established for the ImPACT cognitive composites, few studies have evaluated the psychometric properties of the ImPACT's Post-Concussion Symptom Scale (PCSS). The purpose of this study was to establish the test-retest reliability of symptom indices associated with the PCSS. Participants included 38 undergraduate students (50.0% male) who underwent neuropsychological testing as part of their participation in their psychology department's research subject pool. The majority of the participants were Caucasian (94.7%) and had no history of concussion (73.7%). All participants completed the ImPACT at two time points, approximately 6 weeks apart. The PCSS was the main outcome measure, and eight symptom indices were calculated (a total symptom score, three symptom summary indices, and four symptom clusters). Pearson correlations (r) and intraclass correlation coefficients (ICCs) were computed as measures of test-retest reliability. Overall, reliabilities ranged from low to high (r = .44 to .80; ICC = .44 to .77). The cognitive symptom cluster exhibited the highest test-retest reliability (r = .80, ICC = .77), followed by the positive symptom total (PST) index, an indicator of the total number of symptoms endorsed (r = .71, ICC = .69). In contrast, the commonly used total symptom score showed lower test-retest reliability (r = .67, ICC = .62). Paired-samples t tests revealed no significant differences between test and retest for any of the symptom variables (all p > .01). Finally, reliable change indices (RCI) were computed to determine whether differences observed between test and retest represented clinically significant change. RCI values were provided for each symptom index at the 80%, 90%, and 95% confidence intervals. These results suggest that evaluating additional symptom

  16. MATLAB-implemented estimation procedure for model-based assessment of hepatic insulin degradation from standard intravenous glucose tolerance test data.

    Science.gov (United States)

    Di Nardo, Francesco; Mengoni, Michele; Morettini, Micaela

    2013-05-01

    Present study provides a novel MATLAB-based parameter estimation procedure for individual assessment of hepatic insulin degradation (HID) process from standard frequently-sampled intravenous glucose tolerance test (FSIGTT) data. Direct access to the source code, offered by MATLAB, enabled us to design an optimization procedure based on the alternating use of Gauss-Newton's and Levenberg-Marquardt's algorithms, which assures the full convergence of the process and the containment of computational time. Reliability was tested by direct comparison with the application, in eighteen non-diabetic subjects, of well-known kinetic analysis software package SAAM II, and by application on different data. Agreement between MATLAB and SAAM II was warranted by intraclass correlation coefficients ≥0.73; no significant differences between corresponding mean parameter estimates and prediction of HID rate; and consistent residual analysis. Moreover, MATLAB optimization procedure resulted in a significant 51% reduction of CV% for the worst-estimated parameter by SAAM II and in maintaining all model-parameter CV% MATLAB-based procedure was suggested as a suitable tool for the individual assessment of HID process. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. Test-retest and between-site reliability in a multicenter fMRI study.

    Science.gov (United States)

    Friedman, Lee; Stern, Hal; Brown, Gregory G; Mathalon, Daniel H; Turner, Jessica; Glover, Gary H; Gollub, Randy L; Lauriello, John; Lim, Kelvin O; Cannon, Tyrone; Greve, Douglas N; Bockholt, Henry Jeremy; Belger, Aysenil; Mueller, Bryon; Doty, Michael J; He, Jianchun; Wells, William; Smyth, Padhraic; Pieper, Steve; Kim, Seyoung; Kubicki, Marek; Vangel, Mark; Potkin, Steven G

    2008-08-01

    In the present report, estimates of test-retest and between-site reliability of fMRI assessments were produced in the context of a multicenter fMRI reliability study (FBIRN Phase 1, www.nbirn.net). Five subjects were scanned on 10 MRI scanners on two occasions. The fMRI task was a simple block design sensorimotor task. The impulse response functions to the stimulation block were derived using an FIR-deconvolution analysis with FMRISTAT. Six functionally-derived ROIs covering the visual, auditory and motor cortices, created from a prior analysis, were used. Two dependent variables were compared: percent signal change and contrast-to-noise-ratio. Reliability was assessed with intraclass correlation coefficients derived from a variance components analysis. Test-retest reliability was high, but initially, between-site reliability was low, indicating a strong contribution from site and site-by-subject variance. However, a number of factors that can markedly improve between-site reliability were uncovered, including increasing the size of the ROIs, adjusting for smoothness differences, and inclusion of additional runs. By employing multiple steps, between-site reliability for 3T scanners was increased by 123%. Dropping one site at a time and assessing reliability can be a useful method of assessing the sensitivity of the results to particular sites. These findings should provide guidance toothers on the best practices for future multicenter studies.

  18. Numerical development of a new correlation between biaxial fracture strain and material fracture toughness for small punch test

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Pradeep [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Dutta, B.K., E-mail: bijon.dutta@gmail.com [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Chattopadhyay, J. [Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094 (India); Reactor Safety Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2017-04-01

    The miniaturized specimens are used to determine mechanical properties of the materials, such as yield stress, ultimate stress, fracture toughness etc. Use of such specimens is essential whenever limited quantity of material is available for testing, such as aged/irradiated materials. The miniaturized small punch test (SPT) is a technique which is widely used to determine change in mechanical properties of the materials. Various empirical correlations are proposed in the literature to determine the value of fracture toughness (J{sub IC}) using this technique. bi-axial fracture strain is determined using SPT tests. This parameter is then used to determine J{sub IC} using available empirical correlations. The correlations between J{sub IC} and biaxial fracture strain quoted in the literature are based on experimental data acquired for large number of materials. There are number of such correlations available in the literature, which are generally not in agreement with each other. In the present work, an attempt has been made to determine the correlation between biaxial fracture strain (ε{sub qf}) and crack initiation toughness (J{sub i}) numerically. About one hundred materials are digitally generated by varying yield stress, ultimate stress, hardening coefficient and Gurson parameters. Such set of each material is then used to analyze a SPT specimen and a standard TPB specimen. Analysis of SPT specimen generated biaxial fracture strain (ε{sub qf}) and analysis of TPB specimen generated value of J{sub i}. A graph is then plotted between these two parameters for all the digitally generated materials. The best fit straight line determines the correlation. It has been also observed that it is possible to have variation in J{sub i} for the same value of biaxial fracture strain (ε{sub qf}) within a limit. Such variation in the value of J{sub i} has been also ascertained using the graph. Experimental SPT data acquired earlier for three materials were then used to get J

  19. Nonlinear Analysis and Post-Test Correlation for a Curved PRSEUS Panel

    Science.gov (United States)

    Gould, Kevin; Lovejoy, Andrew E.; Jegley, Dawn; Neal, Albert L.; Linton, Kim, A.; Bergan, Andrew C.; Bakuckas, John G., Jr.

    2013-01-01

    The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept, developed by The Boeing Company, has been extensively studied as part of the National Aeronautics and Space Administration's (NASA s) Environmentally Responsible Aviation (ERA) Program. The PRSEUS concept provides a light-weight alternative to aluminum or traditional composite design concepts and is applicable to traditional-shaped fuselage barrels and wings, as well as advanced configurations such as a hybrid wing body or truss braced wings. Therefore, NASA, the Federal Aviation Administration (FAA) and The Boeing Company partnered in an effort to assess the performance and damage arrestments capabilities of a PRSEUS concept panel using a full-scale curved panel in the FAA Full-Scale Aircraft Structural Test Evaluation and Research (FASTER) facility. Testing was conducted in the FASTER facility by subjecting the panel to axial tension loads applied to the ends of the panel, internal pressure, and combined axial tension and internal pressure loadings. Additionally, reactive hoop loads were applied to the skin and frames of the panel along its edges. The panel successfully supported the required design loads in the pristine condition and with a severed stiffener. The panel also demonstrated that the PRSEUS concept could arrest the progression of damage including crack arrestment and crack turning. This paper presents the nonlinear post-test analysis and correlation with test results for the curved PRSEUS panel. It is shown that nonlinear analysis can accurately calculate the behavior of a PRSEUS panel under tension, pressure and combined loading conditions.

  20. Correlation between hypoosmotic swelling test and breeding soundness evaluation of adult Nelore bulls

    Directory of Open Access Journals (Sweden)

    Tamires Miranda Neto

    2011-07-01

    Full Text Available This study aimed at evaluating the relationship between physical and morphological semen features with the hypoosmotic swelling (HOS test in raw semen of adult Nelore bulls classified as sound and unsound for breeding. Two hundred and six Nelore bulls aging from 3-10 years old were subjected to breeding soundness examination. After physical and morphological semen examination, HOS test was done. After the breeding soundness examination, 94.2% of the bulls were classified as sound for breeding. There was no difference between the average scrotal circumference of bulls classified as sound and unsound for breeding (P>0.05, but there was difference between all semen physical and morphological aspects of bulls classified as sound and unsound for breeding (P>0.05, but there was no difference in the mean percentage of reactive spermatozoa to HOS test results both for sound (38.4±17.9 and unsound animals (39.5±16.4; P>0.05, with no Pearson correlation between the HOS test and variables. According to these results HOS test can not be used alone to predict the reproductive potential of adult Nelore bulls.

  1. Biomechanical factors associated with time to complete a change of direction cutting maneuver.

    Science.gov (United States)

    Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C

    2014-10-01

    Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.

  2. Unidimensional factor models imply weaker partial correlations than zero-order correlations.

    Science.gov (United States)

    van Bork, Riet; Grasman, Raoul P P P; Waldorp, Lourens J

    2018-06-01

    In this paper we present a new implication of the unidimensional factor model. We prove that the partial correlation between two observed variables that load on one factor given any subset of other observed variables that load on this factor lies between zero and the zero-order correlation between these two observed variables. We implement this result in an empirical bootstrap test that rejects the unidimensional factor model when partial correlations are identified that are either stronger than the zero-order correlation or have a different sign than the zero-order correlation. We demonstrate the use of the test in an empirical data example with data consisting of fourteen items that measure extraversion.

  3. Correlation of Chemical and Physical Test Data for the Environmental Ageing of Tefzel (ETFE)

    Science.gov (United States)

    Morgan, G. J.; Campion, R. P.

    1996-01-01

    In a similar approach to that used for the previously issued correlation report for Coflon (CAPP/M.10), this report aims to identify any correlations between mechanical property changes and chemical/morphological changes for Tefzel, using information supplied in other MERL and TRI project reports (plus latest data which will be included in final reports for Phase 1). Differences identified with Coflon behaviour will be of scientific interest as well as appropriate to project applications, as Tefzel and Coflon are chemical isomers. Owing to the considerable chemical resistance of Tefzel, much of its testing so far has been based on mechanical properties. Where changes have occurred, chemical analysis can now be targeted more effectively. Relevant test data collated here include: tensile modulus and related properties, permeation coefficients, % crystallinity, and other observations where significant. Fluids based on methanol and amine (Fluid G), a mixture of methane, carbon dioxide and hydrogen sulphide gases plus an aqueous amine solution (Fluid F), and an aromatic oil mix of heptane, cyclohexane, toluene and I-propanol (Fluid 1) have affected Tefzel to varying degrees, and are discussed in some detail herein.

  4. Cross-Cultural Adaptation and Validation of the Back Beliefs Questionnaire to the Arabic Language.

    Science.gov (United States)

    Alamrani, Samia; Alsobayel, Hana; Alnahdi, Ali H; Moloney, Niamh; Mackey, Martin

    2016-06-01

    Translation, cross-cultural adaptation, and psychometric testing. To translate the Back Beliefs Questionnaire (BBQ) into Arabic and investigate its psychometric properties in an Arabic-speaking sample of individuals with low back pain (LBP). Back pain beliefs are associated with pain chronicity and disability in people with LBP. The BBQ is a recognized and frequently used tool for measuring these beliefs. To date the BBQ has not been translated into Arabic. The English version of the BBQ was translated and culturally adapted into Arabic (BBQ-Ar) according to published guidelines. The BBQ-Ar was then tested in a sample of 115 Arabic-speaking individuals with LBP. Reliability was evaluated through internal consistency (Cronbach α) and test-retest reliability (intraclass correlation coefficient), the latter in a subgroup of 25. Construct validity was assessed using exploratory factor analysis and by examining the correlation between the BBQ-Ar, the Oswestry Disability Index and a Numerical Pain Rating Scale. Internal consistency of the BBQ-Ar was good (Cronbach α = 0.77). Test-retest reliability was good (intraclass correlation coefficient [2,1] = 0.88). Exploratory factor analysis revealed a three-factor structure, explaining 46% of total variance, with the first factor alone explaining 24%. Eight of the nine scoring items were loaded on the first factor thus forming a unidimensional scale. A significant negative correlation was found between Oswestry Disability Index and BBQ-Ar scores (r = -0.307; P < 0.01), whereas no significant correlation was found between BBQ-Ar and Pain Rating Scale scores. No floor or celling effects were observed. The BBQ-Ar is a valid and reliable tool that can be used to assess back pain beliefs in Arabic-speaking individuals. N/A.

  5. Evaluation of Visual Field Test Parameters after Artificial Tear Administration in Patients with Glaucoma and Dry Eye.

    Science.gov (United States)

    Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin

    2018-01-01

    To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.

  6. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  7. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. The Component Timed-Up-and-Go test: the utility and psychometric properties of using a mobile application to determine prosthetic mobility in people with lower limb amputations.

    Science.gov (United States)

    Clemens, Sheila M; Gailey, Robert S; Bennett, Christopher L; Pasquina, Paul F; Kirk-Sanchez, Neva J; Gaunaurd, Ignacio A

    2018-03-01

    Using a custom mobile application to evaluate the reliability and validity of the Component Timed-Up-and-Go test to assess prosthetic mobility in people with lower limb amputation. Cross-sectional design. National conference for people with limb loss. A total of 118 people with non-vascular cause of lower limb amputation participated. Subjects had a mean age of 48 (±13.7) years and were an average of 10 years post amputation. Of them, 54% ( n = 64) of subjects were male. None. The Component Timed-Up-and-Go was administered using a mobile iPad application, generating a total time to complete the test and five component times capturing each subtask (sit to stand transitions, linear gait, turning) of the standard timed-up-and-go test. The outcome underwent test-retest reliability using intraclass correlation coefficients (ICCs) and convergent validity analyses through correlation with self-report measures of balance and mobility. The Component Timed-Up-and-Go exhibited excellent test-retest reliability with ICCs ranging from .98 to .86 for total and component times. Evidence of discriminative validity resulted from significant differences in mean total times between people with transtibial (10.1 (SD: ±2.3)) and transfemoral (12.76 (SD: ±5.1) amputation, as well as significant differences in all five component times ( P < .05). Convergent validity of the Component Timed-Up-and-Go was demonstrated through moderate correlations with the PLUS-M ( r s  = -.56). The Component Timed-Up-and-Go is a reliable and valid clinical tool for detailed assessment of prosthetic mobility in people with non-vascular lower limb amputation. The iPad application provided a means to easily record data, contributing to clinical utility.

  9. Traditional vs. Sport-Specific Vertical Jump Tests: Reliability, Validity, and Relationship With the Legs Strength and Sprint Performance in Adult and Teen Soccer and Basketball Players.

    Science.gov (United States)

    Rodríguez-Rosell, David; Mora-Custodio, Ricardo; Franco-Márquez, Felipe; Yáñez-García, Juan M; González-Badillo, Juan J

    2017-01-01

    Rodríguez-Rosell, D, Mora-Custodio, R, Franco-Márquez, F, Yáñez-García, JM, González-Badillo, JJ. Traditional vs. sport-specific vertical jump tests: reliability, validity, and relationship with the legs strength and sprint performance in adult and teen soccer and basketball players. J Strength Cond Res 31(1): 196-206, 2017-The vertical jump is considered an essential motor skill in many team sports. Many protocols have been used to assess vertical jump ability. However, controversy regarding test selection still exists based on the reliability and specificity of the tests. The main aim of this study was to analyze the reliability and validity of 2 standardized (countermovement jump [CMJ] and Abalakov jump [AJ]) and 2 sport-specific (run-up with 2 [2-LEGS] or 1 leg [1-LEG] take-off jump) vertical jump tests, and their usefulness as predictors of sprint and strength performance for soccer (n = 127) and basketball (n = 59) players in 3 different categories (Under-15, Under-18, and Adults). Three attempts for each of the 4 jump tests were recorded. Twenty-meter sprint time and estimated 1 repetition maximum in full squat were also evaluated. All jump tests showed high intraclass correlation coefficients (0.969-0.995) and low coefficients of variation (1.54-4.82%), although 1-LEG was the jump test with the lowest absolute and relative reliability. All selected jump tests were significantly correlated (r = 0.580-0.983). Factor analysis resulted in the extraction of one principal component, which explained 82.90-95.79% of the variance of all jump tests. The 1-LEG test showed the lowest associations with sprint and strength performance. The results of this study suggest that CMJ and AJ are the most reliable tests for the estimation of explosive force in soccer and basketball players in different age categories.

  10. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    Science.gov (United States)

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes

  11. Automated collimation testing by determining the statistical correlation coefficient of Talbot self-images.

    Science.gov (United States)

    Rana, Santosh; Dhanotia, Jitendra; Bhatia, Vimal; Prakash, Shashi

    2018-04-01

    In this paper, we propose a simple, fast, and accurate technique for detection of collimation position of an optical beam using the self-imaging phenomenon and correlation analysis. Herrera-Fernandez et al. [J. Opt.18, 075608 (2016)JOOPDB0150-536X10.1088/2040-8978/18/7/075608] proposed an experimental arrangement for collimation testing by comparing the period of two different self-images produced by a single diffraction grating. Following their approach, we propose a testing procedure based on correlation coefficient (CC) for efficient detection of variation in the size and fringe width of the Talbot self-images and thereby the collimation position. When the beam is collimated, the physical properties of the self-images of the grating, such as its size and fringe width, do not vary from one Talbot plane to the other and are identical; the CC is maximum in such a situation. For the de-collimated position, the size and fringe width of the self-images vary, and correspondingly the CC decreases. Hence, the magnitude of CC is a measure of degree of collimation. Using the method, we could set the collimation position to a resolution of 1 μm, which relates to ±0.25   μ    radians in terms of collimation angle (for testing a collimating lens of diameter 46 mm and focal length 300 mm). In contrast to most collimation techniques reported to date, the proposed technique does not require a translation/rotation of the grating, use of complicated phase evaluation algorithms, or an intricate method for determination of period of the grating or its self-images. The technique is fully automated and provides high resolution and precision.

  12. Shortening of an existing generic online health-related quality of life instrument for dogs.

    Science.gov (United States)

    Reid, J; Wiseman-Orr, L; Scott, M

    2017-10-11

    Development, initial validation and reliability testing of a shortened version of a web-based questionnaire instrument to measure generic health-related quality of life in companion dogs, to facilitate smartphone and online use. The original 46 items were reduced using expert judgment and factor analysis. Items were removed on the basis of item loadings and communalities on factors identified through factor analysis of responses from owners of healthy and unwell dogs, intrafactor item correlations, readability of items in the UK, USA and Australia and ability of individual items to discriminate between healthy and unwell dogs. Validity was assessed through factor analysis and a field trial using a "known groups" approach. Test-retest reliability was assessed using intraclass correlation coefficients. The new instrument comprises 22 items, each of which was rated by dog owners using a 7-point Likert scale. Factor analysis revealed a structure with four health-related quality of life domains (energetic/enthusiastic, happy/content, active/comfortable, and calm/relaxed) accounting for 72% of the variability in the data compared with 64% for the original instrument. The field test involving 153 healthy and unwell dogs demonstrated good discriminative properties and high intraclass correlation coefficients. The 22-item shortened form is superior to the original instrument and can be accessed via a mobile phone app. This is likely to increase the acceptability to dog owners as a routine wellness measure in health care packages and as a therapeutic monitoring tool. © 2017 British Small Animal Veterinary Association.

  13. Validation of the Turkish version of the Breast Reduction Assessed Severity Scale.

    Science.gov (United States)

    Kececi, Yavuz; Sir, Emin; Zengel, Baha

    2013-01-01

    Measuring patient-reported outcomes has become increasingly important in cosmetic and reconstructive breast surgery. There is no validated questionnaire in Turkish to evaluate quality-of-life issues for patients with mammary hypertrophy. The authors describe the reliability and validity of a translated Breast Reduction Assessed Severity Scale (BRASS) in evaluating Turkish patients. The BRASS, developed by Sigurdson et al, was translated into Turkish adhering strictly to the guidelines of questionnaire translations. Statistical analysis was carried out with Cronbach's α to test the internal consistency and intraclass correlation coefficient for test-retest reliability. Exploratory factor analysis was carried out using principal component analysis with oblimin rotation to test its construct validity. Correlations between subscales identified in the factor analysis and corresponding domains in the Short Form-36 and Rosenberg Self-Esteem Scale were analyzed. The total instrument was found to have an α coefficient of 0.92 and subscale α coefficients ranging from 0.76 to 0.87. Intraclass correlation coefficient was 0.93 for the total scale and ranged from 0.81 to 0.91 for the subscales. Exploratory factor analysis resulted in a 5-factor structure: physical implications, body pain, physical appearance, poor self-concept, and negative social interactions. With this study, the reliability and validity of the Turkish version of the BRASS were revealed. This translated version can be used to evaluate the effect of mammary hypertrophy on quality of life in Turkish patients.

  14. Mega-impacts and mantle-melting episodes: tests of possible correlations

    International Nuclear Information System (INIS)

    Glikson, A.Y.

    1996-01-01

    The criteria for recognising the effects of impacts by large-diameter extraterrestrial projectiles (D p >>10 km) on thin, geothermally active crust must vary fundamentally from those pertaining to impacts on thick, cooler continental crust. Although the bulk of the terrestrial cratering records has been destroyed by both erosion of elevated terrains and plate subduction, or obscured by burial, a search for Precambrian mega-impacts is facilitated by the preservation of their likely secondary effects: mega-earthquake-triggered faults; ensuing diamictites, and the deposits of turbidity currents; microtektites; spherulitic condensates of vaporised asteroid and target materials; and distal tectonic and igeneous effects. Clues to the origin of thermal events are provided by peaks on isotopic-age histograms of precise U-Pb, Ar-Ar, amd Sm-Nd mineral-whole-rock ages. These peaks, spatially corroborated by detailed mapping of Precambrian terrains, support an episodic nature of at least certain major Precambrian events and some correlations with impact events. Preliminary time-series analyses of Precambrian events yield values consistent with the Phanerozoic galactic rotation period (250 ± 50 Ma), and the solar system's cross-galactic-plane oscillation period (33 ± 3 Ma). It has been demonstrated that possible correlations between mega-impacts and tectonic/thermal events are capable of being tested through isotopic-age studies of diamictites and spherule units of impact origin and of rifting and mafic igneous events. 123 refs., 2 tabs., 7 figs

  15. A Methodological Report: Adapting the 505 Change-of-Direction Speed Test Specific to American Football.

    Science.gov (United States)

    Lockie, Robert G; Farzad, Jalilvand; Orjalo, Ashley J; Giuliano, Dominic V; Moreno, Matthew R; Wright, Glenn A

    2017-02-01

    Lockie, RG, Jalilvand, F, Orjalo, AJ, Giuliano, DV, Moreno, MR, and Wright, GA. A methodological report: Adapting the 505 change-of-direction speed test specific to American football. J Strength Cond Res 31(2): 539-547, 2017-The 505 involves a 10-m sprint past a timing gate, followed by a 180° change-of-direction (COD) performed over 5 m. This methodological report investigated an adapted 505 (A505) designed to be football-specific by changing the distances to 10 and 5 yd. Twenty-five high school football players (6 linemen [LM]; 8 quarterbacks, running backs, and linebackers [QB/RB/LB]; 11 receivers and defensive backs [R/DB]) completed the A505 and 40-yd sprint. The difference between A505 and 0 to 10-yd time determined the COD deficit for each leg. In a follow-up session, 10 subjects completed the A505 again and 10 subjects completed the 505. Reliability was analyzed by t-tests to determine between-session differences, typical error (TE), and coefficient of variation. Test usefulness was examined via TE and smallest worthwhile change (SWC) differences. Pearson's correlations calculated relationships between the A505 and 505, and A505 and COD deficit with the 40-yd sprint. A 1-way analysis of variance (p ≤ 0.05) derived between-position differences in the A505 and COD deficit. There were no between-session differences for the A505 (p = 0.45-0.76; intraclass correlation coefficient = 0.84-0.95; TE = 2.03-4.13%). Additionally, the A505 was capable of detecting moderate performance changes (SWC0.5 > TE). The A505 correlated with the 505 and 40-yard sprint (r = 0.58-0.92), suggesting the modified version assessed similar qualities. Receivers and defensive backs were faster than LM in the A505 for both legs, and right-leg COD deficit. Quarterbacks, running backs, and linebackers were faster than LM in the right-leg A505. The A505 is reliable, can detect moderate performance changes, and can discriminate between football position groups.

  16. Correlation of analysis with high level vibration test results for primary coolant piping

    International Nuclear Information System (INIS)

    Park, Y.J.; Hofmayer, C.H.; Costello, J.F.

    1992-01-01

    Dynamic tests on a modified 1/2.5-scale model of pressurized water reactor (PWR) primary coolant piping were performed using a large shaking table at Tadotsu, Japan. The High Level Vibration Test (HLVT) program was part of a cooperative study between the United States (Nuclear Regulatory Commission/Brookhaven National Laboratory, NRC/BNL) and Japan (Ministry of International Trade and Industry/Nuclear Power Engineering Center). During the test program, the excitation level of each test run was gradually increased up to the limit of the shaking table and significant plastic strains, as well as cracking, were induced in the piping. To fully utilize the test results, NRC/BNL sponsored a project to develop corresponding analytical predictions for the nonlinear dynamic response of the piping for selected test runs. The analyses were performed using both simplified and detailed approaches. The simplified approaches utilize a linear solution and an approximate formulation for nonlinear dynamic effects such as the use of a deamplification factor. The detailed analyses were performed using available nonlinear finite element computer codes, including the MARC, ABAQUS, ADINA and WECAN codes. A comparison of various analysis techniques with the test results shows a higher prediction error in the detailed strain values in the overall response values. A summary of the correlation analyses was presented before the BNL. This paper presents a detailed description of the various analysis results and additional comparisons with test results

  17. Correlation between spermatogenesis disorders and rat testes CYP2E1 mRNA contents under experimental alcoholism or type I diabetes.

    Science.gov (United States)

    Shayakhmetova, Ganna M; Bondarenko, Larysa B; Matvienko, Anatoliy V; Kovalenko, Valentina M

    2014-09-01

    The aim of the study was to investigate the correlation between spermatogenesis disorders and CYP2E1 mRNA contents in testes of rats with experimental alcoholism or type I diabetes. Two pathological states characterized by CYP2E1 induction were simulated on Wistar male rats: experimental alcoholism and type I diabetes. As controls for each state, equal number of animals (of the same age and weight) were used. Morphological evaluation of rat testes was carried out. The spermatogenic epithelium state was estimated by four points system. CYP2E1 mRNA expression was rated by method of reverse transcriptase polymerase chain reaction. Pearson correlation coefficients were used for describing relationships between variables. The presence of alcoholism and diabetes-mediated quantitative and qualitative changes in male rat spermatogenic epithelium in comparison with norm has been demonstrated. The increased levels of testes CYP2E1 have been fixed simultaneously. CYP2E1 mRNA content negatively strongly correlated with spermatogenic index value (r=-0.99; Palcoholism. The strong correlation between CYP2E1 mRNA content and number of spermatogonia (r=0.99; P<0.001) and "windows" occurrence (r=0.96; P<0.001) has been fixed in diabetic rats testes. Present investigation has demonstrated that the testicular failure following chronic ethanol consumption and diabetes type I in male rats accompanied CYP2E1 mRNA over-expression in testes. The correlation between the levels of CYP2E1 mRNA in testes and spermatogenesis disorders allow supposing the involvement of CYP2E1 into the non-specific pathogenetic mechanisms of male infertility under above-mentioned pathologies. Copyright © 2014 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  18. How to assess and compare inter-rater reliability, agreement and correlation of ratings: an exemplary analysis of mother-father and parent-teacher expressive vocabulary rating pairs

    Directory of Open Access Journals (Sweden)

    Margarita eStolarova

    2014-06-01

    Full Text Available This report has two main purposes. First, we combine well-known analytical approaches to conduct a comprehensive assessment of agreement and correlation of rating-pairs and to dis-entangle these often confused concepts, providing a best-practice example on concrete data and a tutorial for future reference. Second, we explore whether a screening questionnaire deve-loped for use with parents can be reliably employed with daycare teachers when assessing early expressive vocabulary. A total of 53 vocabulary rating pairs (34 parent-teacher and 19 mother-father pairs collected for two-year-old children (12 bilingual are evaluated. First, inter-rater reliability both within and across subgroups is assessed using the intra-class correlation coefficient (ICC. Next, based on this analysis of reliability and on the test-retest reliability of the employed tool, inter-rater agreement is analyzed, magnitude and direction of rating differences are considered. Finally, Pearson correlation coefficients of standardized vocabulary scores are calculated and compared across subgroups. The results underline the necessity to distinguish between reliability measures, agreement and correlation. They also demonstrate the impact of the employed reliability on agreement evaluations. This study provides evidence that parent-teacher ratings of children’s early vocabulary can achieve agreement and correlation comparable to those of mother-father ratings on the assessed vocabulary scale. Bilingualism of the evaluated child decreased the likelihood of raters’ agreement. We conclude that future reports of agree-ment, correlation and reliability of ratings will benefit from better definition of terms and stricter methodological approaches. The methodological tutorial provided here holds the potential to increase comparability across empirical reports and can help improve research practices and knowledge transfer to educational and therapeutic settings.

  19. Laterality judgments in people with low back pain--A cross-sectional observational and test-retest reliability study.

    Science.gov (United States)

    Linder, Martin; Michaelson, Peter; Röijezon, Ulrik

    2016-02-01

    Disruption of cortical representation, or body schema, has been indicated as a factor in the persistence and recurrence of low back pain (LBP). This has been observed through impaired laterality judgment ability and it has been suggested that this ability is affected in a spatial rather than anatomical manner. We compared laterality judgment performance of foot and trunk movements between people with LBP with or without leg pain and healthy controls, and investigated associations between test performance and pain. We also assessed the test-retest reliability of the Recognise Online™ software when used in a clinical and a home setting. Cross-sectional observational and test-retest study. Thirty individuals with LBP and 30 healthy controls performed judgment tests of foot and trunk laterality once supervised in a clinic and twice at home. No statistically significant group differences were found. LBP intensity was negatively related to trunk laterality accuracy (p = 0.019). Intraclass correlation values ranged from 0.51 to 0.91. Reaction time improved significantly between test occasions while accuracy did not. Laterality judgments were not impaired in subjects with LBP compared to controls. Further research may clarify the relationship between pain mechanisms in LBP and laterality judgment ability. Reliability values were mostly acceptable, with wide and low confidence intervals, suggesting test-retest reliability for Recognise Online™ could be questioned in this trial. A significant learning effect was observed which should be considered in clinical and research application of the test. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Needs of caregivers of cancer patients: validation of the Mexican version of the Support Person Unmet Needs Survey (SPUNS-SFM).

    Science.gov (United States)

    Doubova, Svetlana V; Aguirre-Hernandez, Rebeca; Infante-Castañeda, Claudia; Martinez-Vega, Ingrid; Pérez-Cuevas, Ricardo

    2015-10-01

    The purpose of this study was to validate the Mexican version of the Support Person Unmet Needs Survey (SPUNS-SFM). A cross-sectional survey that included 826 primary caregivers of cancer patients was conducted from June to December 2013 at the Oncology Hospital of the Mexican Institute of Social Security in Mexico City. The validation procedure comprised (1) content validity through a group of experts; (2) construct validity through an exploratory factor analysis based on the polychoric correlation matrix; (3) internal consistency using Cronbach's alpha; (4) convergent validity between SPUNS-SFM and quality of life, anxiety-and-depression scales by calculating Spearman's rank correlation coefficient;( 5) discriminative validity through the Wilcoxon rank-sum test; and (6) test-retest reliability using intraclass correlation coefficient. SPUNS-SFM has 23 items with six factors accounting for 65 % of the total variance. The domains were concerns about the future, access and continuity of healthcare, information, work and finance, and personal and emotional needs. Cronbach's alpha values ranged from 0.70 to 0.88 among factors. SPUNS-SFM had moderate convergent validity compared with quality of life and depression-and-anxiety scales and good discriminative validity, revealing high needs for younger caregivers and more emotional needs for caregivers of patients with advanced cancer stages. Intraclass correlation coefficient between SPUNS-SFM measurements was 0.78. SPUNS-SFM is a valid and reliable tool to identify needs of caregivers of cancer patients.

  1. Hepatobiliary magnetic resonance imaging in patients with liver disease: correlation of liver enhancement with biochemical liver function tests

    Energy Technology Data Exchange (ETDEWEB)

    Kukuk, Guido M.; Schaefer, Stephanie G.; Hadizadeh, Dariusch R.; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Bonn (Germany); Fimmers, Rolf [University of Bonn, Department of Medical Biometry, Informatics and Epidemiology, Bonn (Germany); Ezziddin, Samer [Department of Nuclear Medicine, Bonn (Germany); Spengler, Ulrich [Department of Internal Medicine I, Bonn (Germany)

    2014-10-15

    To evaluate hepatobiliary magnetic resonance imaging (MRI) using Gd-EOB-DTPA in relation to various liver function tests in patients with liver disorders. Fifty-one patients with liver disease underwent Gd-EOB-DTPA-enhanced liver MRI. Based on region-of-interest (ROI) analysis, liver signal intensity was calculated using the spleen as reference tissue. Liver-spleen contrast ratio (LSCR) and relative liver enhancement (RLE) were calculated. Serum levels of total bilirubin, gamma glutamyl transpeptidase (GGT), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glutamate dehydrogenase (GLDH), lactate dehydrogenase (LDH), serum albumin level (AL), prothrombin time (PT), creatinine (CR) as well as international normalised ratio (INR) and model for end-stage liver disease (MELD) score were tested for correlation with LSCR and RLE. Pre-contrast LSCR values correlated with total bilirubin (r = -0.39; p = 0.005), GGT (r = -0.37; p = 0.009), AST (r = -0.38; p = 0.013), ALT (r = -0.29; p = 0.046), PT (r = 0.52; p < 0.001), GLDH (r = -0.55; p = 0.044), INR (r = -0.42; p = 0.003), and MELD Score (r = -0.53; p < 0.001). After administration of Gd-EOB-DTPA bilirubin (r = -0.45; p = 0.001), GGT (r = -0.40; p = 0.004), PT (r = 0.54; p < 0.001), AST (r = -0.46; p = 0.002), ALT (r = -0.31; p = 0.030), INR (r = -0.45; p = 0.001) and MELD Score (r = -0.56; p < 0.001) significantly correlated with LSCR. RLE correlated with bilirubin (r = -0.40; p = 0.004), AST (r = -0.38; p = 0.013), PT (r = 0.42; p = 0.003), GGT (r = -0.33; p = 0.020), INR (r = -0.36; p = 0.011) and MELD Score (r = -0.43; p = 0.003). Liver-spleen contrast ratio and relative liver enhancement using Gd-EOB-DTPA correlate with a number of routinely used biochemical liver function tests, suggesting that hepatobiliary MRI may serve as a valuable biomarker for liver function. The strongest correlation with liver enhancement was found for the MELD Score. (orig.)

  2. Strength testing and training of rowers: a review.

    Science.gov (United States)

    Lawton, Trent W; Cronin, John B; McGuigan, Michael R

    2011-05-01

    In the quest to maximize average propulsive stroke impulses over 2000-m racing, testing and training of various strength parameters have been incorporated into the physical conditioning plans of rowers. Thus, the purpose of this review was 2-fold: to identify strength tests that were reliable and valid correlates (predictors) of rowing performance; and, to establish the benefits gained when strength training was integrated into the physical preparation plans of rowers. The reliability of maximal strength and power tests involving leg extension (e.g. leg pressing) and arm pulling (e.g. prone bench pull) was high (intra-class correlations 0.82-0.99), revealing that elite rowers were significantly stronger than their less competitive peers. The greater strength of elite rowers was in part attributed to the correlation between strength and greater lean body mass (r = 0.57-0.63). Dynamic lower body strength tests that determined the maximal external load for a one-repetition maximum (1RM) leg press (kg), isokinetic leg extension peak force (N) or leg press peak power (W) proved to be moderately to strongly associated with 2000-m ergometer times (r = -0.54 to -0.68; p training experience and muscle morphology, in that those individuals with greater training experience and/or proportions of slow twitch fibres performed more repetitions. Muscle balance ratios derived from strength data (e.g. hamstring-quadriceps ratio training may be counterproductive to strength development over the shorter term (i.e. training within the sequence of training units should be considered, particularly over the non-competition phase (e.g. 2-6 sets × 4-12 repetitions, three sessions a week). Maximal strength was sustained when infrequent (e.g. one or two sessions a week) but intense (e.g. 73-79% of maximum) strength training units were scheduled; however, it was unclear whether training adaptations should emphasize maximal strength, endurance or power in order to enhance

  3. Correlation of Chemical and Physical Test Data for the Environmental Ageing of Tefzel (ETFE). Revised

    Science.gov (United States)

    Morgan, G. J.; Campion, R. P.

    1997-01-01

    In a similar approach to that used for the previously issued correlation report for Coflon (CAPP/M.10), this report aims to identify any correlations between mechanical property changes and chemical/morphological changes for Tefzel, using information supplied in other MERL and TRI project reports. Differences identified with Coflon behaviour will be of scientific interest as well as appropriate to project applications, as Tefzel and Coflon are chemical isomers. Owing to the considerable chemical resistance of Tefzel, much of its testing so far has been based on mechanical properties. Where changes have occurred, chemical analysis can now be targeted more effectively. Relevant test data collated here include: tensile modulus and related properties, permeation coefficients, % crystallinity, some crack growth resistance measurements, and other observations where significant. Fluids based on methanol and amine (Fluid G), a mixture of methane, carbon dioxide and hydrogen sulphide gases plus an aqueous amine solution (Fluid F), and an aromatic oil mix of heptane, cyclohexane, toluene and 1-propanol (Fluid I) have affected Tefzel to varying degrees, and are discussed in some detail herein.

  4. Status of the Correlation Process of the V-HAB Simulation with Ground Tests and ISS Telemetry Data

    Science.gov (United States)

    Ploetner, P.; Roth, C.; Zhukov, A.; Czupalla, M.; Anderson, M.; Ewert, M.

    2013-01-01

    The Virtual Habitat (V-HAB) is a dynamic Life Support System (LSS) simulation, created for investigation of future human spaceflight missions. It provides the capability to optimize LSS during early design phases. The focal point of the paper is the correlation and validation of V-HAB against ground test and flight data. In order to utilize V-HAB to design an Environmental Control and Life Support System (ECLSS) it is important to know the accuracy of simulations, strengths and weaknesses. Therefore, simulations of real systems are essential. The modeling of the International Space Station (ISS) ECLSS in terms of single technologies as well as an integrated system and correlation against ground and flight test data is described. The results of the simulations make it possible to prove the approach taken by V-HAB.

  5. The Performance of the Upper Limb scores correlate with pulmonary function test measures and Egen Klassifikation scores in Duchenne muscular dystrophy.

    Science.gov (United States)

    Lee, Ha Neul; Sawnani, Hemant; Horn, Paul S; Rybalsky, Irina; Relucio, Lani; Wong, Brenda L

    2016-01-01

    The Performance of the Upper Limb scale was developed as an outcome measure specifically for ambulant and non-ambulant patients with Duchenne muscular dystrophy and is implemented in clinical trials needing longitudinal data. The aim of this study is to determine whether this novel tool correlates with functional ability using pulmonary function test, cardiac function test and Egen Klassifikation scale scores as clinical measures. In this cross-sectional study, 43 non-ambulatory Duchenne males from ages 10 to 30 years and on long-term glucocorticoid treatment were enrolled. Cardiac and pulmonary function test results were analyzed to assess cardiopulmonary function, and Egen Klassifikation scores were analyzed to assess functional ability. The Performance of the Upper Limb scores correlated with pulmonary function measures and had inverse correlation with Egen Klassifikation scores. There was no correlation with left ventricular ejection fraction and left ventricular dysfunction. Body mass index and decreased joint range of motion affected total Performance of the Upper Limb scores and should be considered in clinical trial designs. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Adaptação e validação do Alcohol Use Disorder Identification Test (AUDIT para população ribeirinha do interior da Amazônia, Brasil Adaptation and validation of the Alcohol Use Disorders Identification Test (AUDIT for a river population in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    Rodrigo Otávio Moretti-Pires

    2011-03-01

    Full Text Available O objetivo deste artigo foi validar o Alcohol Use Disorders Identification Test (AUDIT para a população do interior do Amazonas, Brasil. A versão original em Inglês foi traduzida para o Português, usando-se o procedimento recomendado pela Organização Mundial da Saúde. O texto foi, então, retraduzido e enviado para um tradutor inglês nativo, que aprovou a tradução. O AUDIT foi administrado a 361 habitantes, três vezes, em um período de duas semanas (teste e reteste. Os dados foram analisados para a confiabilidade e consistência interna. O alfa de Cronbach foi de 0,87 na primeira aplicação, 0,87 na segunda e 0,86 na terceira. A confiabilidade Teste/Reteste foi avaliada usando-se o coeficiente de correlação intraclasse, que para a pontuação total do AUDIT foi de 0,93. A área sob a curva ROC foi de 0,805 no ponto de corte sete (sensibilidade de 76,4% e especificidade 75%. Conclusões: a versão do AUDIT validada mostra-se internamente consistente e estável no contexto investigado, destacando-se a necessidade de avaliação de outras propriedades psicométricas.The objective of this study was to validate the Alcohol Use Disorders Identification Test (AUDIT for a river population in the Brazilian Amazon. The original English version of AUDIT was translated into Portuguese, using the procedure recommended by the World Health Organization. The text was then back-translated and submitted to a native English translator, who approved the translation. AUDIT was administered to 361 inhabitants for a total of three times in two weeks. Data were analyzed for test/retest reliability and internal consistency. Cronbach's alpha was 0.87 at the first interview, 0.87 at the second, and 0.86 at the third. Test/retest reliability assessed via the intra-class correlation coefficient for the total AUDIT scale was 0.93. Area under ROC was 0.805 for a cutoff of seven (sensitivity 76.4%; specificity 75%. The validated AUDIT proved to be internally

  7. Assessment of Technical Skills in Young Soccer Goalkeepers: Reliability and Validity of Two Goalkeeper-Specific Tests

    Directory of Open Access Journals (Sweden)

    Ricardo Rebelo-Gonçalves, António J. Figueiredo, Manuel J. Coelho-e-Silva, Antonio Tessitore

    2016-09-01

    Full Text Available The purpose of this study was to evaluate the reproducibility and validity of two new tests designed to examine goalkeeper-specific technique. Twenty-six goalkeepers (14.49 ± 2.52 years old completed two trial sessions, each separated by one week, to evaluate the reproducibility of the Sprint-Keeper Test (S-Keeper and the Lateral Shuffle-Keeper Test (LS-Keeper. Construct validity was assessed among forty goalkeepers (14.49 ± 1.71 years old by competitive level (elite versus non-elite, after controlling for chronological age. All participants were examined in vertical jump (CMJ and CMJ-free arms, acceleration (5-m and 10-m sprint and goalkeeper-specific technique. The S-Keeper requires the goalkeeper to accelerate during 3 m and dive over a stationary ball after performing a change of direction in a total distance of 10 m. The LS-Keeper involves three changes of direction and a diving save over a stationary ball, in a total distance of 12.55 m. Performance was respectively measured as total time for the right and left sides in each protocol. Bivariate correlations between repeated measures were high and significant (r = 0.835 – 0.912. Test-retest results for the S-Keeper and LS-Keeper showed good reliability (reliability coefficients > 0.88, intra-class correlation coefficient > 0.908 and coefficients of variation < 4.37%, even though participants tended to improve performance when diving to their right side (p < 0.05. Both tests were able to detect significant differences between elite and non-elite goalkeepers, particularly to the left side (p < 0.05. These findings suggest that the S-Keeper and LS-Keeper are reliable and valid tests for assessing goalkeeper-specific technique. Both protocols can be used as a practical tool to provide relevant information about the influence of several components of performance in the overall execution of a diving save, particularly movement patterns, take-off movements and possible asymmetries.

  8. Correlation and agreement between eplet mismatches calculated using serological, low-intermediate and high resolution molecular human leukocyte antigen typing methods.

    Science.gov (United States)

    Fidler, Samantha; D'Orsogna, Lloyd; Irish, Ashley B; Lewis, Joshua R; Wong, Germaine; Lim, Wai H

    2018-03-02

    Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960-0.975) and 0.926 (95% CI 0.899-0.944), respectively; and 0.995 (95% CI 0.994-0.996) and 0.993 (95% CI 0.991-0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation.

  9. MR volumetric assessment of endolymphatic hydrops

    International Nuclear Information System (INIS)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E.; Dietrich, O.; Flatz, W.; Ertl-Wagner, B.; Keeser, D.

    2015-01-01

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  10. Cross-cultural adaptation of the Norwegian versions of the Roland-Morris Disability Questionnaire and the Oswestry Disability Index.

    Science.gov (United States)

    Grotle, M; Brox, J I; Vøllestad, N K

    2003-09-01

    To evaluate reliability and construct validity of the Norwegian versions of the Roland Morris Disability Questionnaire and the modified Oswestry Disability Index. Translation of two functional status questionnaires and a cross-sectional study of measurement properties. The questionnaires were translated and back-translated following the Guillemin criteria. The Norwegian versions were tested for 55 patients with acute low back pain and 50 patients with chronic low back pain. Test-retest with a 2-day interval was performed in a subsample of 28 patients from the chronic sample. Reliability was assessed by repeatability according to Bland and Altman, intraclass coefficient and coefficient of variation. Internal consistency was assessed by Cronbach's alpha. Concurrent construct validity was assessed with correlations between the questionnaires and the SF-36, Disability Rating Index and pain intensity. Repeatability of the Roland Morris Disability Questionnaire was 4 points, coefficient of variation 15% and intraclass correlation coefficient 0.89, and of the modified Oswestry Disability Index 11, 12% and 0.88, respectively. Internal consistency was 0.94 for both questionnaires. The questionnaires correlated highly with the physical functioning scale of SF-36, moderately with pain, and low with mental scales of the SF-36. The reliability and construct validity of the Norwegian versions of the Roland Morris Disability Questionnaire and the modified Oswestry Disability Index are acceptable for assessing functional status of Norwegian-speaking patients with low back pain.

  11. MR volumetric assessment of endolymphatic hydrops

    Energy Technology Data Exchange (ETDEWEB)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E. [University of Munich, Department of Otorhinolaryngology Head and Neck Surgery, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); Dietrich, O.; Flatz, W.; Ertl-Wagner, B. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); Keeser, D. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psychiatry and Psychotherapy, Innenstadtkliniken Medical Centre, Munich (Germany)

    2014-10-16

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  12. Test-retest reliability and predictors of unreliable reporting for a sexual behavior questionnaire for U.S. men.

    Science.gov (United States)

    Nyitray, Alan G; Harris, Robin B; Abalos, Andrew T; Nielson, Carrie M; Papenfuss, Mary; Giuliano, Anna R

    2010-12-01

    Accurate knowledge about human sexual behaviors is important for increasing our understanding of human sexuality; however, there have been few studies assessing the reliability of sexual behavior questionnaires designed for community samples of adult men. A test-retest reliability study was conducted on a questionnaire completed by 334 men who had been recruited in Tucson, Arizona. Reliability coefficients and refusal rates were calculated for 39 non-sexual and sexual behavior questionnaire items. Predictors of unreliable reporting for lifetime number of female sexual partners were also assessed. Refusal rates were generally low, with slightly higher refusal rates for questions related to immigration, income, the frequency of sexual intercourse with women, lifetime number of female sexual partners, and the lifetime number of male anal sex partners. Kappa and intraclass correlation coefficients were substantial or almost perfect for all non-sexual and sexual behavior items. Reliability dropped somewhat, but was still substantial, for items that asked about household income and the men's knowledge of their sexual partners' health, including abnormal Pap tests and prior sexually transmitted diseases (STD). Age and lifetime number of female sexual partners were independent predictors of unreliable reporting while years of education was inversely associated with unreliable reporting. These findings among a community sample of adult men are consistent with other test-retest reliability studies with populations of women and adolescents.

  13. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  14. NRC test results and operations experience provide insights for a new gate valve stem force correlation

    International Nuclear Information System (INIS)

    Watkins, John C.; Steele, Robert Jr.; DeWall, Kevin G.; Weidenhamer, G.H.; Rothberg, O.O.

    1994-01-01

    This paper presents the results of testing sponsored by the NRC to assess valve and motor operator performance under varying pressure and fluid conditions. This effort included an examination of the methods used by the industry to predict the required stem force of a valve, and research to provide guidelines for the extrapolation of in situ test results to design basis conditions.Years ago, when most of these valves were originally installed, the industry used a set of equations to determine analytically that the valves' motor-operators were large enough and the control switches were set high enough to close the valves at their design basis conditions. Our research has identified several inconsistencies with the industry's existing gate valve stem force equation and has challenged the overly simplistic assumptions inherent in its use. This paper discusses the development of the INEL correlation, which serves as the basis for a method to bound the stem force necessary to close flexwedge gate valves whose operational characteristics have been shown to be predictable. As utilities undertake to provide assurance of their valves' operability, this ability to predict analytically the required stem force is especially important for valves that cannot be tested at design basis conditions. For such valves, the results of tests conducted at less severe conditions can be used with the INEL correlation to make the necessary prediction. ((orig.))

  15. Development and Psychometric Validation of HIPER-Q to Assess Knowledge of Hypertensive Patients in Cardiac Rehabilitation.

    Science.gov (United States)

    Santos, Rafaella Zulianello Dos; Bonin, Christiani Decker Batista; Martins, Eliara Ten Caten; Pereira Junior, Moacir; Ghisi, Gabriela Lima de Melo; Macedo, Kassia Rosangela Paz de; Benetti, Magnus

    2018-01-01

    The absence of instruments capable of measuring the level of knowledge of hypertensive patients in cardiac rehabilitation programs about their disease reflects the lack of specific recommendations for these patients. To develop and validate a questionnaire to evaluate the knowledge of hypertensive patients in cardiac rehabilitation programs about their disease. A total of 184 hypertensive patients (mean age 60.5 ± 10 years, 66.8% men) were evaluated. Reproducibility was assessed by calculation of the intraclass correlation coefficient using the test-retest method. Internal consistency was assessed by the Cronbach's alpha and the construct validity by the exploratory factorial analysis. The final version of the instrument had 17 questions organized in areas considered important for patient education. The instrument proposed showed a clarity index of 8.7 (0.25). The intraclass correlation coefficient was 0.804 and the Cronbach's correlation coefficient was 0.648. Factor analysis revealed five factors associated with knowledge areas. Regarding the criterion validity, patients with higher education level and higher family income showed greater knowledge about hypertension. The instrument has a satisfactory clarity index and adequate validity, and can be used to evaluate the knowledge of hypertensive participants in cardiac rehabilitation programs.

  16. Change of liver echogenicity in chronic renal failure: Correlation with serologic test and pathologic findings

    International Nuclear Information System (INIS)

    Eun, Hyo Won; Cho, Kyoung Sik; Kim, Jeong Kon; Kim, Jung Hoon

    2002-01-01

    To correlate serologic test and pathologic findings with change of hepatic parenchymal echogenicity on ultrasound (US) in patients with chronic renal failure. From January 1995 to April 2000, among eight hundred eighty four patients with kidney transplantation due to chronic renal failure, sixty seven patients who underwent US-guided liver biopsy were selected. Change of liver echogenicity on US was analyzed, and this change was compared with serologic test and pathologic findings. Among sixty seven patients, pathologic findings of thirty four patients with the normal liver echogenicity on US revealed normal in 15 patients (44%), viral hepatitis in 18 (53%), and liver cirrhosis in one patient (3%). Meanwhile, twenty seven patients with chronic liver disease on US were pathologically confirmed as normal in 13 patients (48%), viral hepatitis in 11 (40%), liver cirrhosis in four patients (11%); six patients with cirrhotic change on US, liver cirrhosis in four patients (67%) and viral hepatitis on two patients (33%). Serologic test of thirty four patients with the normal liver echogenicity on US showed positive HBs Ag in 17 patients (50%), positive anti-HCV Ab in 11 (32%), positive in both HBs Ag and anti-HCV Ab in one (3%), and normal result in five patients (15%). In patients with chronic renal failure, it is nor enough to determine the presence of liver disease only based on change of echogenicity on US. A careful correlation with serologic test and, if needed, pathologic confirmation are recommended for the accurate preoperative evaluation of the liver.

  17. Reliability and Validity of Food Frequency Questions to Assess Beverage and Food Group Intakes among Low-Income 2- to 4-Year-Old Children.

    Science.gov (United States)

    Koleilat, Maria; Whaley, Shannon E

    2016-06-01

    Fruits, vegetables, sweetened foods, and beverages have been found to have positive and negative associations with obesity in early childhood, yet no rapid assessment tools are available to measure intake of these foods among preschoolers. This study examines the test-retest reliability and validity of a 10-item Child Food and Beverage Intake Questionnaire designed to assess fruits, vegetables, and sweetened foods and beverages intake among 2- to 4-year-old children. The Child Food and Beverage Intake Questionnaire was developed for use in periodic phone surveys conducted with low-income families with preschool-aged children. Seventy primary caregivers of 2- to 4-year-old children completed two Child Food and Beverage Intake Questionnaires within a 2-week period for test-retest reliability. Participants also completed three 24-hour recalls to allow assessment of validity. Intraclass correlations were used to examine test-retest reliability. Spearman rank correlation coefficients, Bland-Altman plots, and linear regression analyses were used to examine validity of the Child Food and Beverage Intake Questionnaire compared with three 24-hour recalls. Intraclass correlations between Child Food and Beverage Intake Questionnaire administrations ranged from 0.48 for sweetened drinks to 0.87 for regular sodas. Intraclass correlations for fruits, vegetables, and sweetened food were 0.56, 0.49, and 0.56, respectively. Spearman rank correlation coefficients ranged from 0.15 to 0.59 for beverages, with 0.46 for sugar-sweetened beverages. Spearman rank correlation coefficients for fruits, vegetables, and sweetened food were 0.30, 0.33, and 0.30, respectively. Although observation of the Bland-Altman plots and linear regression analyses showed a slight upward trend in mean differences, with increasing mean intake for five beverage groups, at least 90% of data plots fell within the limits of agreement for all food/beverage groups. The Child Food and Beverage Intake Questionnaire

  18. Correlation Between Bone and Soft Tissue Thickness in Maxillary Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Nasrin Esfahanizadeh

    2016-12-01

    Full Text Available Objectives: The purpose of this study was to determine buccal bone and soft tissue thicknesses and their correlation in the maxillary anterior region using cone beam computed tomography (CBCT.Materials and Methods: In this cross sectional study, 330 sound maxillary incisors in 60 patients with a mean age of 37.5 years were assessed by CBCT scans. For better visualization of soft tissue, patients were asked to use plastic retractors in order to retract their lips and cheeks away from the gingival tissue before taking the scans. Measurements were made in three different positions: at the crest and at 2 and 5mm apical to the crest. The cementoenamel junction‒crest distance was measured. for data analyses, the Pearson’s correlation coefficient, ANOVA and intraclass correlation coefficient were used.Results: There were mildly significant linear associations between labial soft tissue and bone thickness in the canines and incisors (r<0.40, P<0.05, but no association was found for the lateral incisors. The mean thickness of buccal bone differed significantly in the maxillary anterior teeth, being greater for the lateral incisors (P<0.05. For soft tissue thickness, the results were the same, and the least thickness was recorded for the canines. There was a mild association between labial soft tissue and bone thickness in canines and incisors (r=0.2, P=0.3, but no such linear association was seen for the lateral incisors.Conclusions: The mean thickness of buccal bone and soft tissue in the anterior maxilla was <1mm and there was a mild linear correlation between them.Keywords: Facial Bones; Cone-Beam Computed Tomography; Maxilla; Esthetics, Dental

  19. Interrater and test-retest reliability and validity of the Norwegian version of the BESTest and mini-BESTest in people with increased risk of falling.

    Science.gov (United States)

    Hamre, Charlotta; Botolfsen, Pernille; Tangen, Gro Gujord; Helbostad, Jorunn L

    2017-04-20

    The Balance Evaluation Systems Test (BESTest) was developed to assess underlying systems for balance control in order to be able to individually tailor rehabilitation interventions to people with balance disorders. A short form, the Mini-BESTest, was developed as a screening test. The study aimed to assess interrater and test-retest reliability of the Norwegian version of the BESTest and the Mini-BESTest in community-dwelling people with increased risk of falling and to assess concurrent validity with the Fall Efficacy Scale-International (FES-I), and it was an observational study with a cross-sectional design. Forty-two persons with increased risk of falling (elderly over 65 years of age, persons with a history of stroke or Multiple Sclerosis) were assessed twice by two raters. Relative reliability was analysed with Intraclass Correlation Coefficient (ICC), and absolute reliability with standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity was assessed against the FES-I using Spearman's rho. The BESTest showed very good interrater reliability (ICC = 0.98, SEM = 1.79, SDC 95  = 5.0) and test-retest reliability (rater A/rater B = ICC = 0.89/0.89, SEM = 3.9/4.3, SDC 95  = 10.8/11.8). The Mini-BESTest also showed very good interrater reliability (ICC = 0.95, SEM = 1.19, SDC 95  = 3.3) and test-retest reliability (rater A/rater B = ICC = 0.85/0.84, SEM = 1.8/1.9, SDC 95  = 4.9/5.2). The correlations were moderate between the FES-I and both the BESTest and the Mini-BESTest (Spearman's rho -0.51 and-0.50, p test-retest reliability when assessed in a heterogeneous sample of people with increased risk of falling. The concurrent validity measured against the FES-I showed moderate correlation. The results are comparable with earlier studies and indicate that the Norwegian versions can be used in daily clinic and in research.

  20. Test-retest reliability of the Military Pre-training Questionnaire.

    Science.gov (United States)

    Robinson, M; Stokes, K; Bilzon, J; Standage, M; Brown, P; Thompson, D

    2010-09-01

    Musculoskeletal injuries are a significant cause of morbidity during military training. A brief, inexpensive and user-friendly tool that demonstrates reliability and validity is warranted to effectively monitor the relationship between multiple predictor variables and injury incidence in military populations. To examine the test-retest reliability of the Military Pre-training Questionnaire (MPQ), designed specifically to assess risk factors for injury among military trainees across five domains (physical activity, injury history, diet, alcohol and smoking). Analyses were based on a convenience sample of 58 male British Army trainees. Kappa (kappa), weighted kappa (kappa(w)) and intraclass correlation coefficients (ICC) were used to evaluate the 2-week test-retest reliability of the MPQ. For index measures constituting the assessment of a given construct, internal consistency was assessed by Cronbach's alpha (alpha) coefficients. Reliability of individual items ranged from poor to almost perfect (kappa range = 0.45-0.86; kappa(w) range = 0.11-0.91; ICC range = 0.34-0.86) with most items demonstrating moderate reliability. Overall scores related to physical activity, diet, alcohol and smoking constructs were reliable between both administrations (ICC = 0.63-0.85). Support for the internal consistency of the incorporated alcohol (alpha = 0.78) and cigarette (alpha = 0.75) scales was also provided. The MPQ is a reliable self-report instrument for assessing multiple injury-related risk factors during initial military training. Further assessment of the psychometric properties of the MPQ (e.g. different types of validity) with military populations/samples will support its interpretation and use in future surveillance and epidemiological studies.

  1. Reliability and Usefulness of the 30-15 Intermittent Fitness Test in Male and Female Professional Futsal Players

    Directory of Open Access Journals (Sweden)

    Valladares-Rodríguez Santiago

    2017-12-01

    Full Text Available The purpose of this study was to determine the reliability and usefulness of the 30-15 Intermittent Fitness Test (30-15IFT in professional male and female futsal players. Thirteen male (24.4 ± 5.6 years; 174.5 ± 10.3 cm; 70.3 ± 9.9 kg and fourteen female (23.3 ± 4.5 years; 165.8 ± 6.2 cm; 61.7 ± 5.5 kg professional futsal players performed the 30-15IFT on two occasions, separated by 5 days. Maximal intermittent running velocity (VIFT and heart rate at exhaustion (HRpeak data were collected for both tests. Reliability was assessed by the intraclass correlation coefficient (ICC, typical error (TE expressed as a coefficient of variation (CV, and smallest worthwhile change (SWC. VIFT demonstrated very good reliability between sessions, both for male (ICC = 0.92 and female (ICC = 0.96 players. As the TE for VIFT and HRpeak was similar to the calculated SWC for both male and female players, the usefulness of the test was rated as “medium”. A change in performance of at least 2 stages in male players, or a change of more than 1 stage in female players could be interpreted as a meaningful change in aerobic futsal fitness. The results of this study demonstrate that the 30-15IFT is both a reliable and useful test for male and female professional futsal players.

  2. Reliability and validity of the test of incremental respiratory endurance measures of inspiratory muscle performance in COPD.

    Science.gov (United States)

    Formiga, Magno F; Roach, Kathryn E; Vital, Isabel; Urdaneta, Gisel; Balestrini, Kira; Calderon-Candelario, Rafael A; Campos, Michael A; Cahalin, Lawrence P

    2018-01-01

    The Test of Incremental Respiratory Endurance (TIRE) provides a comprehensive assessment of inspiratory muscle performance by measuring maximal inspiratory pressure (MIP) over time. The integration of MIP over inspiratory duration (ID) provides the sustained maximal inspiratory pressure (SMIP). Evidence on the reliability and validity of these measurements in COPD is not currently available. Therefore, we assessed the reliability, responsiveness and construct validity of the TIRE measures of inspiratory muscle performance in subjects with COPD. Test-retest reliability, known-groups and convergent validity assessments were implemented simultaneously in 81 male subjects with mild to very severe COPD. TIRE measures were obtained using the portable PrO2 device, following standard guidelines. All TIRE measures were found to be highly reliable, with SMIP demonstrating the strongest test-retest reliability with a nearly perfect intraclass correlation coefficient (ICC) of 0.99, while MIP and ID clustered closely together behind SMIP with ICC values of about 0.97. Our findings also demonstrated known-groups validity of all TIRE measures, with SMIP and ID yielding larger effect sizes when compared to MIP in distinguishing between subjects of different COPD status. Finally, our analyses confirmed convergent validity for both SMIP and ID, but not MIP. The TIRE measures of MIP, SMIP and ID have excellent test-retest reliability and demonstrated known-groups validity in subjects with COPD. SMIP and ID also demonstrated evidence of moderate convergent validity and appear to be more stable measures in this patient population than the traditional MIP.

  3. Correlation analysis of alveolar bone loss in buccal/palatal and proximal surfaces in rats

    Directory of Open Access Journals (Sweden)

    Carolina Barrera de Azambuja

    2012-12-01

    Full Text Available The aim was to correlate alveolar bone loss in the buccal/palatal and the mesial/distal surfaces of upper molars in rats. Thirty-three, 60-day-old, male Wistar rats were divided in two groups, one treated with alcohol and the other not treated with alcohol. All rats received silk ligatures on the right upper second molars for 4 weeks. The rats were then euthanized and their maxillae were split and defleshed with sodium hypochlorite (9%. The cemento-enamel junction (CEJ was stained with 1% methylene blue and the alveolar bone loss in the buccal/palatal surfaces was measured linearly in 5 points on standardized digital photographs. Measurement of the proximal sites was performed by sectioning the hemimaxillae, restaining the CEJ and measuring the alveolar bone loss linearly in 3 points. A calibrated and blinded examiner performed all the measurements. Intraclass Correlation Coefficient revealed values of 0.96 and 0.89 for buccal/lingual and proximal surfaces, respectively. The Pearson Correlation Coefficient (r between measurements in buccal/palatal and proximal surfaces was 0.35 and 0.05 for the group treated with alcohol, with and without ligatures, respectively. The best correlations between buccal/palatal and proximal surfaces were observed in animals not treated with alcohol, in sites both with and without ligatures (r = 0.59 and 0.65, respectively. A positive correlation was found between alveolar bone loss in buccal/palatal and proximal surfaces. The correlation is stronger in animals that were not treated with alcohol, in sites without ligatures. Areas with and without ligature-induced periodontal destruction allow detection of alveolar bone loss in buccal/palatal and proximal surfaces.

  4. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    Science.gov (United States)

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Reliability of the Wii Balance Board in kayak.

    Science.gov (United States)

    Vando, Stefano; Laffaye, Guillaume; Masala, Daniele; Falese, Lavinia; Padulo, Johnny

    2015-01-01

    the seat of the kayaker represent the principal contact point to express mechanical Energy. therefore we investigated the reliability of the Wii Balance Board measures in the kayak vs. on the ground. Bland-Altman test showed a low systematic bias on the ground (2.85%) and in kayak (-2.13%) respectively; while 0.996 for Intra-class correlation coefficient. the Wii Balance Board is useful to assess postural sway in kayak.

  6. Reproducibility of an aerobic endurance test for nonexpert swimmers

    Directory of Open Access Journals (Sweden)

    Veronese da Costa A

    2012-09-01

    Full Text Available Adalberto Veronese da Costa,1,2 Manoel da Cunha Costa,3 Daniel Medeiros Carlos,1 Luis Marcos de Medeiros Guerra,1,2 Antônio José Silva,2 Tiago Manoel Cabral dos Santos Barbosa2,41Department of Physical Education, Bioscience Laboratory of Human Kinetics, Rio Grande do Norte State University, Mossoró, Brazil; 2Sport Sciences Trás-os-Montes e Alto Douro University, Research Center in Sport, Health and Human Development, Vila Real, Portugal; 3Superior School of Physical Education, Human Performance Laboratory, Pernambuco State University, Recife, Brazil; 4National Institute of Education, Nanyang Technological University, SingaporeBackground: This study aimed to verify the reproduction of an aerobic test to determine nonexpert swimmers' resistance.Methods: The sample consisted of 24 male swimmers (age: 22.79 ± 3.90 years; weight: 74.72 ± 11.44 kg; height: 172.58 ± 4.99 cm; and fat percentage: 15.19% ± 3.21%, who swim for 1 hour three times a week. A new instrument was used in this study (a Progressive Swim Test: the swimmer wore an underwater MP3 player and increased their swimming speed on hearing a beep after every 25 meters. Each swimmer's heart rate was recorded before the test (BHR and again after the test (AHR. The rate of perceived exertion (RPE and the number of laps performed (NLP were also recorded. The sample size was estimated using G*Power software (v 3.0.10; Franz Faul, Kiel University, Kiel, Germany. The descriptive values were expressed as mean and standard deviation. After confirming the normality of the data using both the Shapiro–Wilk and Levene tests, a paired t-test was performed to compare the data. The Pearson's linear correlation (r and intraclass coefficient correlation (ICC tests were used to determine relative reproducibility. The standard error of measurement (SEM and the coefficient of variation (CV were used to determine absolute reproducibility. The limits of agreement and the bias of the absolute and relative

  7. Development of an instrument based on the protection motivation theory to measure factors influencing women's intention to first pap test practice.

    Science.gov (United States)

    Hassani, Lale; Dehdari, Tahereh; Hajizadeh, Ebrahim; Shojaeizadeh, Davoud; Abedini, Mehrandokht; Nedjat, Saharnaz

    2014-01-01

    Given that there are many Iranian women who have never had a Pap smear, this study was designed to develop and validate a measurement tool based on the Protection Motivation Theory to assess factors influencing the Iranian women's intention to perform first Pap testing. In this psychometric research, to determine the Content Validity Index (CVI) and the Content Validity Ratio (CVR), a panel of experts (n=10) reviewed scale items. Reliability was estimated through the Intraclass Correlation Coefficient (n=30) and internal consistency (n=240). Also, factor analysis (exploratory and conformity) was performed on the data of the sample women who had never had a Pap smear test (n=240). A 26-item questionnaire was developed. The CVI and CVR scores of the scale were 0.89 and 0.90, respectively. Exploratory factor analysis loaded a 26-item with seven factors questionnaire (perceived vulnerability and severity, fear, response costs, response efficacy, self-efficacy, and protection motivation (or intention)) that jointly accounted for 72.76% of the observed variance. Confirmatory factor analysis indicated a good fit for the data. Internal consistency (range 0.70-0.93) and test-retest reliability (range 0.72-0.96) of sub-scales were acceptable. This study showed that the designed instrument was a valid and reliable tool for measuring the factors influencing the women's intention to perform their first Pap testing.

  8. Investigating the correlation between wastewater analysis and roadside drug testing in South Australia.

    Science.gov (United States)

    Bade, Richard; Tscharke, Benjamin J; Longo, Marie; Cooke, Richard; White, Jason M; Gerber, Cobus

    2018-04-10

    The societal impact of drug use is well known. An example is when drug-intoxicated drivers increase the burden on policing and healthcare services. This work presents the correlation of wastewater analysis (using UHPLC-MS/MS) and positive roadside drug testing results for methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and cannabis from December 2011-December 2016 in South Australia. Methamphetamine and MDMA showed similar trends between the data sources with matching increases and decreases, respectively. Cannabis was relatively steady based on wastewater analysis, but the roadside drug testing data started to diverge in the final part of the measurement period. The ability to triangulate data as shown here validates both wastewater analysis and roadside drug testing. This suggests that changes in overall population drug use revealed by WWA is consistent and proportional with changes in drug-driving behaviours. The results show that, at higher levels of drug use as measured by wastewater analysis, there is an increase in drug driving in the community and therefore more strain on health services and police. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Application of Computational Fluid Dynamics (CFD) in transonic wind-tunnel/flight-test correlation

    Science.gov (United States)

    Murman, E. M.

    1982-01-01

    The capability for calculating transonic flows for realistic configurations and conditions is discussed. Various phenomena which were modeled are shown to have the same order of magnitude on the influence of predicted results. It is concluded that CFD can make the following contributions to the task of correlating wind tunnel and flight test data: some effects of geometry differences and aeroelastic distortion can be predicted; tunnel wall effects can be assessed and corrected for; and the effects of model support systems and free stream nonuniformities can be modeled.

  10. Agility in Team Sports: Testing, Training and Factors Affecting Performance.

    Science.gov (United States)

    Paul, Darren J; Gabbett, Tim J; Nassis, George P

    2016-03-01

    Agility is an important characteristic of team sports athletes. There is a growing interest in the factors that influence agility performance as well as appropriate testing protocols and training strategies to assess and improve this quality. The objective of this systematic review was to (1) evaluate the reliability and validity of agility tests in team sports, (2) detail factors that may influence agility performance, and (3) identify the effects of different interventions on agility performance. The review was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We conducted a search of PubMed, Google Scholar, Science Direct, and SPORTDiscus databases. We assessed the methodological quality of intervention studies using a customized checklist of assessment criteria. Intraclass correlation coefficient values were 0.80-0.91, 0.10-0.81, and 0.81-0.99 for test time using light, video, and human stimuli. A low-level reliability was reported for youth athletes using the video stimulus (0.10-0.30). Higher-level participants were shown to be, on average, 7.5% faster than their lower level counterparts. Reaction time and accuracy, foot placement, and in-line lunge movement have been shown to be related to agility performance. The contribution of strength remains unclear. Efficacy of interventions on agility performance ranged from 1% (vibration training) to 7.5% (small-sided games training). Agility tests generally offer good reliability, although this may be compromised in younger participants responding to various scenarios. A human and/or video stimulus seems the most appropriate method to discriminate between standard of playing ability. Decision-making and perceptual factors are often propositioned as discriminant factors; however, the underlying mechanisms are relatively unknown. Research has focused predominantly on the physical element of agility. Small-sided games and video training may offer effective

  11. Correlation of secretory phospholipase-A2 activity and fatty acids in cerebrospinal fluid with liver enzymes tests

    Directory of Open Access Journals (Sweden)

    Sepideh Ghodoosifar

    2016-02-01

    Full Text Available Introduction: The aim was to determine whether secretory phospholipase-A2 (sPLA2 activity and fatty acids in cerebrospinal fluid (CSF are correlated with liver enzymes tests. Methods: CSF and serum samples were collected from 49 patients (age 18-65 as part of routine diagnostic testing. Along with serum liver enzymes aspartate aminotransferase (AST, alanine aminotransferase (ALT and alkaline phosphatase (ALP, the fatty acid composition of CSF was measured by gas liquid chromatography. CSF enzyme activities of sPLA2 were measured using the standard assay with diheptanoyl thio-phosphatidylcholin as substrate. Results: The saturated fatty acids (SFAs including palmitic acid and stearic acid were positively, and the unsaturated fatty acids including oleic acid and linoleic acid were negatively correlated with liver enzymes tests. In regression analysis with adjustment for body mass index (BMI, the elevated liver enzymes tests were positively associated with activity of sPLA2 (β > 0.31, P 0.38, P < 0.010 and negatively with total monounsaturated fatty acids (MUFAs (β < -0.40, P < 0.001 contents of CSF. Conclusion: CSF activity of sPLA2 and fatty acids may be linked to peripheral markers of liver function, suggesting an indirect impact of central fatty acids on hepatocytes function and metabolism.

  12. Test-retest reliability of a questionnaire to assess physical environmental factors pertaining to physical activity

    Directory of Open Access Journals (Sweden)

    McGinn Aileen P

    2005-06-01

    Full Text Available Abstract Background Despite the documented benefits of physical activity, many adults do not obtain the recommended amounts. Barriers to physical activity occur at multiple levels, including at the individual, interpersonal, and environmental levels. Only until more recently has there been a concerted focus on how the physical environment might affect physical activity behavior. With this new area of study, self-report measures should be psychometrically tested before use in research studies. Therefore the objective of this study was to document the test-retest reliability of a questionnaire designed to assess physical environmental factors that might be associated with physical activity in a diverse adult population. Methods Test and retest surveys were conducted over the telephone with 106 African American and White women and men living in either Forsyth County, North Carolina or Jackson, Mississippi. Reliability of self-reported environmental factors across four domains (e.g., access to facilities and destinations, functionality and safety, aesthetics, natural environment was determined using intraclass correlation coefficients (ICC overall and separately by gender and race. Results Generally items displayed moderate and sometimes substantial reliability (ICC between 0.4 to 0.8, with a few differences by gender or race, across each of the domains. Conclusion This study provides some psychometric evidence for the use of many of these questions in studies examining the effect of self-reported physical environmental measures on physical activity behaviors, among African American and White women and men.

  13. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment

    OpenAIRE

    Nornoo, Adwoa O.; Jackson, Jonathan; Axtell, Samantha

    2017-01-01

    Objective. To determine whether there is a correlation between pharmacy students? scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking.

  14. Stability of FDG-PET Radiomics features - An integrated analysis of test-retest and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Leijenaar, Ralph T. H.; Carvalho, Sara; Rios Velazquez, Emmanuel [Dept. of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht Univ. Medical Center, Maastricht (Netherlands)] [and others

    2013-10-15

    Purpose: Besides basic measurements as maximum standardized uptake value (SUV){sub max} or SUV{sub mean} derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. 'Radiomics' features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup. Methods: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50 % of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spear man's rank correlation coefficient. Results: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET

  15. [Standardization of the Test Your Memory and evaluation of their concordance with the outcome of the psychometric examination].

    Science.gov (United States)

    Ferrero-Arias, J; Turrión-Rojo, M A

    2016-05-01

    To explore the relationship between scores on the Test Your Memory (TYM) battery and findings from a more exhaustive neurocognitive assessment. The TYM and fourteen psychometric tests were administered to 84 subjects aged 50 or older who attended an outpatient neurology clinic due to cognitive symptoms. Each patient's cognitive state was determined independently from his/her score on the TYM (CDR 0, n=25; CDR 0.5, n=45; CDR 1, n=14). We analysed concurrent validity of TYM scores and results from the psychometric tests, as well as the degree of concordance between the two types of measurement, by contrasting normalised data from each instrument. Although the intraclass correlation coefficient was 0.67 (confidence interval 95%, 0.53-0.77), analysis of the Bland-Altman plot and the curve on the survival-agreement plot (Luiz et al. method) demonstrates that the individual distances between the two methods exhibit excessive dispersion from a clinical viewpoint. TYM-based predictions of the mean z-score on psychometric tests differed substantially from real results in 30% of the subjects. Concordance of 95% can only be achieved by accepting absolute inter-instrument differences of up to 0.87 as identical values. Furthermore, the TYM underestimates cognitive performance for low values and overestimates it for high values. The TYM is a cognitive screening test which should not be used to predict results on psychometric tests or to detect cognitive changes in clinical trials. Copyright © 2014 Sociedad Española de Neurología. Published by Elsevier España, S.L.U. All rights reserved.

  16. Development of the Italian version of the revised Scoliosis Research Society-22 Patient Questionnaire, SRS-22r-I: cross-cultural adaptation, factor analysis, reliability, and validity.

    Science.gov (United States)

    Monticone, Marco; Baiardi, Paola; Calabrò, David; Calabrò, Fabio; Foti, Calogero

    2010-11-15

    Evaluation of the psychometric properties of a translated and culturally adapted questionnaire. Translating, culturally adapting, and validating the Italian version of the revised Scoliosis Research Society-22 Patient Questionnaire (SRS-22r-I) in order to allow its use with Italian-speaking patients with adolescent idiopathic scoliosis (AIS). Increasing attention is being given to health-related quality of life measures as a means of adding information about the evaluation of AIS. A translated form of the revised SRS-22 has never been validated in Italian patients with AIS. The development of the SRS-22 questionnaire involved its translation and back-translation, a final review by an Expert Committee, and testing of the prefinal version to establish its correspondence to the original English version. Psychometric testing included factor analysis, reliability by internal consistency (Cronbach alpha) and test-retest repeatability (Intraclass Coefficient Correlation), and concurrent validity (Pearson correlation) by comparing the SRS-22r-I domains with the Short-Form Health Survey (SF-36) subscales. It took 4 months to develop a shared version of the SRS-22r-I, which proved to be satisfactorily acceptable when administered to 223 subjects with AIS. Factor analysis indicated a 4-factor solution (54% of the explained variance), and the questionnaire had an acceptable level of internal consistency (α = 0.77) and a high level of test-retest reliability (intraclass correlation coefficient = 0.957). In terms of concurrent validity, the correlations with the related Short-Form-36 subscales were moderate to good in the case of the Pain and Mental Health domains, and moderate in the case of the Function and Self-Image domains. The Italian translation of the SRS-22r has a good factorial structure and psychometric properties, and replicates the results of existing English versions of the questionnaire. Its use for research purposes can therefore be recommended.

  17. Test-retest variability of high resolution positron emission tomography (PET) imaging of cortical serotonin (5HT2A) receptors in older, healthy adults

    International Nuclear Information System (INIS)

    Chow, Tiffany W; Mamo, David C; Uchida, Hiroyuki; Graff-Guerrero, Ariel; Houle, Sylvain; Smith, Gwenn S; Pollock, Bruce G; Mulsant, Benoit H

    2009-01-01

    Position emission tomography (PET) imaging using [ 18 F]-setoperone to quantify cortical 5-HT 2A receptors has the potential to inform pharmacological treatments for geriatric depression and dementia. Prior reports indicate a significant normal aging effect on serotonin 5HT 2A receptor (5HT 2A R) binding potential. The purpose of this study was to assess the test-retest variability of [ 18 F]-setoperone PET with a high resolution scanner (HRRT) for measuring 5HT 2A R availability in subjects greater than 60 years old. Methods: Six healthy subjects (age range = 65–78 years) completed two [ 18 F]-setoperone PET scans on two separate occasions 5–16 weeks apart. The average difference in the binding potential (BP ND ) as measured on the two occasions in the frontal and temporal cortical regions ranged between 2 and 12%, with the lowest intraclass correlation coefficient in anterior cingulate regions. We conclude that the test-retest variability of [ 18 F]-setoperone PET in elderly subjects is comparable to that of [ 18 F]-setoperone and other 5HT 2A R radiotracers in younger subject samples

  18. Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.

    Science.gov (United States)

    Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan

    2014-11-01

    To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients 18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.

  19. SAS Code for Calculating Intraclass Correlation Coefficients and Effect Size Benchmarks for Site-Randomized Education Experiments

    Science.gov (United States)

    Brandon, Paul R.; Harrison, George M.; Lawton, Brian E.

    2013-01-01

    When evaluators plan site-randomized experiments, they must conduct the appropriate statistical power analyses. These analyses are most likely to be valid when they are based on data from the jurisdictions in which the studies are to be conducted. In this method note, we provide software code, in the form of a SAS macro, for producing statistical…

  20. Correlation between HRCT findings, pulmonary function tests and bronchoalveolar lavage cytology in interstitial lung disease associated with rheumatoid arthritis

    International Nuclear Information System (INIS)

    Biederer, J.; Muhle, C.; Heller, M.; Reuter, M.; Schnabel, A.; Gross, W.L.

    2004-01-01

    A prospective study correlating high-resolution computed tomography (HRCT), lung function tests (PFT) and bronchoalveolar lavage (BAL) cytology in patients with interstitial lung disease (ILD) associated with rheumatoid arthritis (RA). Fifty-three RA patients with suspected ILD (19 men, 34 women) underwent 71 HRCT (14 of 53 with sequential HRCT, mean follow-up 24.3 months). The HRCT evaluation by two observers on consensus included a semi-quantitative characterisation of lesion pattern and profusion on representative anatomical levels. Fifty-two HRCT were followed by PFT and BAL. Agreement or discordance of HRCT-, PFT- and BAL findings were analysed with Pearson's correlation, κ score and McNemar's test. Tobacco-fume exposure was estimated in pack years. Smoking/non-smoking groups were compared with Student's t test. In 49 of 53 patients, HRCT was suggestive of ILD associated with RA (66 of 71 HRCT). Reticular lesions were found in 40 of 53 patients, in 15 of 40 presenting as mixed pattern with ground-glass opacities (GGO). Pure reticular patterns predominated in patients with long duration of ILD (p>0.01). Pure GGO were not observed. Lesion profusion was highly variable and correlated moderately negative with diffusion capacity (mean 88.2% (SD±20.9%); r=-0.54; p 0.2), but not towards lymphocytosis (κ=0.10; p=0.23; McNemar test p>0.2). Differences in smoking history were not significant (p>0.1). The HRCT appears most appropriate for the detection and follow-up of ILD associated with RA. The PFT and BAL correlate only partially with lesion profusion or grading on HRCT, but they contribute valuable information about dynamic lung function and differential diagnoses (pneumonia, medication side effects). (orig.)

  1. Degree of skin denervation and its correlation to objective thermal sensory test in leprosy patients.

    Directory of Open Access Journals (Sweden)

    Ismael Alves Rodrigues Júnior

    Full Text Available BACKGROUND: Leprosy is an infectious disease affecting skin and peripheral nerves resulting in increased morbidity and physical deformities. Early diagnosis provides opportune treatment and reduces its complications, relying fundamentally on the demonstration of impaired sensation in suggestive cutaneous lesions. The loss of tactile sensitivity in the lesions is preceded by the loss of thermal sensitivity, stressing the importance of the thermal test in the suspicious lesions approach. The gold-standard method for the assessment of thermal sensitivity is the quantitative sensory test (QST. Morphological study may be an alternative approach to access the thin nerve fibers responsible for thermal sensitivity transduction. The few studies reported in leprosy patients pointed out a rarefaction of thin dermo-epidermal fibers in lesions, but used semi-quantitative evaluation methods. METHODOLOGY/PRINCIPAL FINDINGS: This work aimed to study the correlation between the degree of thermal sensitivity impairment measured by QST and the degree of denervation in leprosy skin lesions, evaluated by immunohistochemistry anti-PGP 9.5 and morphometry. Twenty-two patients were included. There were significant differences in skin thermal thresholds among lesions and contralateral skin (cold, warm, cold induced pain and heat induced pain. The mean reduction in the density of intraepidermal and subepidermal fibers in lesions was 79.5% (SD = 19.6 and 80.8% (SD = 24.9, respectively. CONCLUSIONS/SIGNIFICANCE: We observed a good correlation between intraepidermal and subepidermal fibers deficit, but no correlation between these variables and those accounting for the degree of impairment in thermal thresholds, since the thin fibers rarefaction was homogeneously intense in all patients, regardless of the degree of sensory deficit. We believe that the homogeneously intense denervation in leprosy lesions should be objective of further investigations focused on its

  2. Three-Dimensional Digital Image Correlation of a Composite Overwrapped Pressure Vessel During Hydrostatic Pressure Tests

    Science.gov (United States)

    Revilock, Duane M., Jr.; Thesken, John C.; Schmidt, Timothy E.

    2007-01-01

    Ambient temperature hydrostatic pressurization tests were conducted on a composite overwrapped pressure vessel (COPV) to understand the fiber stresses in COPV components. Two three-dimensional digital image correlation systems with high speed cameras were used in the evaluation to provide full field displacement and strain data for each pressurization test. A few of the key findings will be discussed including how the principal strains provided better insight into system behavior than traditional gauges, a high localized strain that was measured where gages were not present and the challenges of measuring curved surfaces with the use of a 1.25 in. thick layered polycarbonate panel that protected the cameras.

  3. Development, equivalence study, and normative data of version B of the Spanish-language Free and Cued Selective Reminding Test.

    Science.gov (United States)

    Grau-Guinea, L; Pérez-Enríquez, C; García-Escobar, G; Arrondo-Elizarán, C; Pereira-Cutiño, B; Florido-Santiago, M; Piqué-Candini, J; Planas, A; Paez, M; Peña-Casanova, J; Sánchez-Benavides, G

    2018-05-08

    The Free and Cued Selective Reminding Test (FCSRT) is widely used for the assessment of verbal episodic memory, mainly in patients with Alzheimer disease. A Spanish version of the FCSRT and normative data were developed within the NEURONORMA project. Availability of alternative, equivalent versions is useful for following patients up in clinical settings. This study aimed to develop an alternative version of the original FCSRT (version B) and to study its equivalence to the original Spanish test (version A), and its performance in a sample of healthy individuals, in order to develop reference data. We evaluated 232 healthy participants of the NEURONORMA-Plus project, aged between 18 and 90. Thirty-three participants were assessed with both versions using a counterbalanced design. High intra-class correlation coefficients (between 0.8 and 0.9) were observed in the equivalence study. While no significant differences in performance were observed in total recall scores, free recall scores were significantly lower for version B. These preliminary results suggest that the newly developed FCSRT version B is equivalent to version A in the main variables tested. Further studies are necessary to ensure interchangeability between versions. We provide normative data for the new version. Copyright © 2018 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Deformation effect and five-fold correlation time reversal test in neutron resonances using aligned 165Ho

    International Nuclear Information System (INIS)

    Huffman, P.R.; Roberson, N.R.; Gould, C.R.; Haase, D.G.

    1993-01-01

    In 1988, Bunakov proposed a test of parity (P) even time reversal (T) violation in the neighborhood of two interfering p-wave resonances of the same spin. A similar enhancement exists if a d-wave and s-wave resonance interfere. Until now, however, no suitable resonances have been located in nuclei which can be aligned, and the only tests of time reversal violation in neutron transmission have been carried out with MeV-energy neutrons. The authors estimate the deformation effect cross sections for neutron resonances in aligned 165 Ho, and estimate the sensitivity of a five-fold correlation time reversal test carried out on a resonance that exhibits a deformation effect

  5. Interscan variation of semi-automated volumetry of subsolid pulmonary nodules

    International Nuclear Information System (INIS)

    Scholten, Ernst T.; Jong, Pim A. de; Willemink, Martin J.; Mali, Willem P.T.M.; Gietema, Hester A.; Jacobs, Colin; Riel, Sarah van; Ginneken, Bram van; Vliegenthart, Rozemarijn; Oudkerk, Matthijs; Koning, Harry J. de; Horeweg, Nanda; Prokop, Mathias

    2015-01-01

    We aimed to test the interscan variation of semi-automatic volumetry of subsolid nodules (SSNs), as growth evaluation is important for SSN management. From a lung cancer screening trial all SSNs that were stable over at least 3 months were included (N = 44). SSNs were quantified on the baseline CT by two observers using semi-automatic volumetry software for effective diameter, volume, and mass. One observer also measured the SSNs on the second CT 3 months later. Interscan variation was evaluated using Bland-Altman plots. Observer agreement was calculated as intraclass correlation coefficient (ICC). Data are presented as mean (± standard deviation) or median and interquartile range (IQR). A Mann-Whitney U test was used for the analysis of the influence of adjustments on the measurements. Semi-automatic measurements were feasible in all 44 SSNs. The interscan limits of agreement ranged from -12.0 % to 9.7 % for diameter, -35.4 % to 28.6 % for volume and -27.6 % to 30.8 % for mass. Agreement between observers was good with intraclass correlation coefficients of 0.978, 0.957, and 0.968 for diameter, volume, and mass, respectively. Our data suggest that when using our software an increase in mass of 30 % can be regarded as significant growth. (orig.)

  6. Interscan variation of semi-automated volumetry of subsolid pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Scholten, Ernst T. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Kennemer Gasthuis, Department of Radiology, Haarlem (Netherlands); Jong, Pim A. de; Willemink, Martin J.; Mali, Willem P.T.M.; Gietema, Hester A. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Jacobs, Colin; Riel, Sarah van [Radboud University Medical Center, Diagnostic Image Analysis Group, Nijmegen (Netherlands); Ginneken, Bram van [Radboud University Medical Center, Diagnostic Image Analysis Group, Nijmegen (Netherlands); Fraunhofer MEVIS, Bremen (Germany); Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Centre Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Koning, Harry J. de [Erasmus Medical Center, Department of Public Health, Rotterdam (Netherlands); Horeweg, Nanda [Erasmus Medical Center, Department of Public Health, Rotterdam (Netherlands); Erasmus Medical Center, Department of Pulmonology, Rotterdam (Netherlands); Prokop, Mathias [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands)

    2015-04-01

    We aimed to test the interscan variation of semi-automatic volumetry of subsolid nodules (SSNs), as growth evaluation is important for SSN management. From a lung cancer screening trial all SSNs that were stable over at least 3 months were included (N = 44). SSNs were quantified on the baseline CT by two observers using semi-automatic volumetry software for effective diameter, volume, and mass. One observer also measured the SSNs on the second CT 3 months later. Interscan variation was evaluated using Bland-Altman plots. Observer agreement was calculated as intraclass correlation coefficient (ICC). Data are presented as mean (± standard deviation) or median and interquartile range (IQR). A Mann-Whitney U test was used for the analysis of the influence of adjustments on the measurements. Semi-automatic measurements were feasible in all 44 SSNs. The interscan limits of agreement ranged from -12.0 % to 9.7 % for diameter, -35.4 % to 28.6 % for volume and -27.6 % to 30.8 % for mass. Agreement between observers was good with intraclass correlation coefficients of 0.978, 0.957, and 0.968 for diameter, volume, and mass, respectively. Our data suggest that when using our software an increase in mass of 30 % can be regarded as significant growth. (orig.)

  7. Cultural adaptation and validation of the Filipino version of Kidney Disease Quality of Life--Short Form (KDQOL-SF version 1.3).

    Science.gov (United States)

    Bataclan, Rommel P; Dial, Ma Antonietta D

    2009-10-01

    Chronic kidney disease is the 10th leading cause of death among Filipinos. Those with chronic kidney disease are exposed to stressors which effect their daily lives. Therefore, assessment of health-related quality of life is important in these patients. The objective of the present study was to translate the Kidney Disease Quality of Life--Short Form version 1.3 (KDQOL-SF ver. 1.3) into Filipino and measure its validity and reliability. Translation and cultural adaptation began with two translations into Filipino, with reconciliation of the forward translators. Pretesting with 10 renal patients, review by experts (nephrologist, translator and dialysis nurse) and back-translation was also done. The final questionnaire was administered to 80 patients with chronic renal disease undergoing haemodialysis for at least 3 months, who could understand Filipino, and were without life-threatening or terminal conditions at the time of the test. A convenience sample of 30 patients from the group had a repeat test 10-14 days after to determine test-retest reliability. Test-retest reliability was assessed by intraclass correlation coefficient and internal consistency reliability was measured by determining the Cronbach's alpha value. Validity was measured using Pearson's correlation between the overall health rating scale and the items from the questionnaire. All of the items showed good test-retest reliability (intraclass correlation coefficient >0.40), ranging from 0.58 (social interaction) to 0.98 (role--emotional). Internal consistency reliability values were acceptable, with Cronbach's alpha ranging from 0.60 (cognitive function) to 0.80 (physical functioning and role--physical). Regarding construct validity, overall health rating in kidney disease-targeted scales was significantly correlated with symptoms/problems, effects of kidney disease and burden of kidney disease. All items in the SF 36 scales had significant correlation with overall health rating (P < 0.05) except

  8. Test of inscribed description in the Alzheimer`s disease: correlation of neuro-psychology and of cerebral sanguinary rates; Test de description ecrite dans la maladie d`Alzheimer: correlation de la neuro-psychologie et des debits sanguins cerebraux

    Energy Technology Data Exchange (ETDEWEB)

    Houzard, C.; Croisile, B.; Philippon, B.; Hibert, O.; Gogoleva, S.M.; Itti, R.; Cinotti, L.; Wertheimer, H.P. [CERMEP, Lyon (France)

    1997-12-31

    The alteration of the written description of an image scene constitutes an early and sensible indicator in diagnosing the Alzheimer`s disease (AD). Measurements of cerebral blood rates (CBR) by SPECT show characteristic regional anomalies. We have studied correlations between the neuro-psychological tests (NT), parameters of description (description of the image of a thief of crackers) and CBR in patients afflicted by AD. Ten patients afflicted by AD of slow onset (MMSE 20.2{+-} 5.1) were subject to the following NTs: MMSE, Wounded A, Battery of Aphasia, BNT, verbal fluence, gesticulative practice, direct and inversion span, copy of a figure, immediate recall of a figure, immediate recall of a story. The description variables were the length of texts (words, phrases), the items of information, the grammatical, semantic and orthographic errors. The relative variations of CBR were obtained after injection by HMPAO - {sup 99m}Tc. The indices of asymmetry were calculated by the method of the regions of interest and the correlations were calculated between the NTs, description variables and L/R asymmetry by SPECT. For the temporal lobes the correlations are significant with: Battery of Aphasia and BNT (p < 0.01), and recall of a story (p < 0.05); in the anterior frontal lobes with: MMSE and direct span (p < 0.05); in the posterior frontal lobes with: Battery of Aphasia (p < 0.05), BNT and recall of a story (p < 0.01). For writing, the grammatical errors are correlated with the anterior frontal asymmetries (p < 0.03); the semantic errors with the anterior and posterior frontal lobes (p < 0.02) and with the temporal lobes (p < 0.05). Our results show a correlations of the frontal and temporal asymmetries with the early degradation of the scores of written semantic errors and the oral tests of language. The grammatical errors appearing later and in severe forms of AD as the attention abilities are connected only to anterior frontal asymmetries. Different functional

  9. Validity and reliability of the one-mile walk test (the Rockport Fitness Walk Test among 70-to-79 year old women

    Directory of Open Access Journals (Sweden)

    Priscila Marques

    2009-06-01

    Full Text Available The purpose of this study was to verify the reliability and concurrent validity of the One-Mile Walk Test (OMWT (The Rockport Fitness Walk Test, Kline et al., 1987, as a preditor of the maximal oxygen consumption (VO2max among women aged 70 to 79 years. The study used a convenient sample, composed by 30 healthy seniors from Florianópolis, SC. Data collection was structured in three phases: 1 answering questionnaires on sociodemographics, on readiness for physical activity (PAR-Q and on physical activity level (IPAQ. Anthropometric variables were measured and the participant performed the first evaluation of the RFWT. Afterwards, the subject visited the laboratory for a treadmill walk and for a trial of the equipments (K4 b2 - COSMED to be used during the stress test (ST for directly measuring the VO2max; 2 the seniors performed the ST following an incremental test protocol, from 2.4 km.h-1 to 5.6 km.h-1 with grades varying from 0% to 15%; 3 the second RFWT. The statistical analyses included the criteria suggested by Lohman (1992 for validity and the procedures were performed using the SPSS (v. 7.5 and MedCalc (v. 9.1. The level of significance was established at 5%. For reliability, the generalized (GE and sex-specific equations (SSE presented high intraclass correlation coefficients (ICC=0.942 and 0.948, p < 0,001 for predicted VO2max and low standard error of the estimate (1.14 and 1.48 ml O2.kg-1.min-1. For validity, the predicted VO2max was underestimated by both equations (GE=17.11±5.97 ml O2.kg-1.min-1; SSE=17.15±4.99 ml O2.kg-1.min-1 vs measured VO2max=26.67±3.53 ml O2.kg-1.min-1 (p < 0.001, and low correlation coeficients (r=0.488 and 0.471 between predicted and measured VO2max were observed. The equations presented high constant error (-9.56 and –9.53 ml O2.kg-1.min-1, with only 16.7% of agreement between the methods. Therefore, the RFWT was reliable, however, not valid for predicting VO2max among active elderly women aged 70 to

  10. Validity and reliability of the one-mile walk test (the Rockport Fitness Walk Test among 70-to-79 year old women

    Directory of Open Access Journals (Sweden)

    Priscila Marques

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n3p364   The purpose of this study was to verify the reliability and concurrent validity of the One-Mile Walk Test (OMWT (The Rockport Fitness Walk Test, Kline et al., 1987, as a preditor of the maximal oxygen consumption (VO2max among women aged 70 to 79 years. The study used a convenient sample, composed by 30 healthy seniors from Florianópolis, SC. Data collection was structured in three phases: 1 answering questionnaires on sociodemographics, on readiness for physical activity (PAR-Q and on physical activity level (IPAQ. Anthropometric variables were measured and the participant performed the first evaluation of the RFWT. Afterwards, the subject visited the laboratory for a treadmill walk and for a trial of the equipments (K4 b2 - COSMED to be used during the stress test (ST for directly measuring the VO2max; 2 the seniors performed the ST following an incremental test protocol, from 2.4 km.h-1 to 5.6 km.h-1 with grades varying from 0% to 15%; 3 the second RFWT. The statistical analyses included the criteria suggested by Lohman (1992 for validity and the procedures were performed using the SPSS (v. 7.5 and MedCalc (v. 9.1. The level of significance was established at 5%. For reliability, the generalized (GE and sex-specific equations (SSE presented high intraclass correlation coefficients (ICC=0.942 and 0.948, p < 0,001 for predicted VO2max and low standard error of the estimate (1.14 and 1.48 ml O2.kg-1.min-1. For validity, the predicted VO2max was underestimated by both equations (GE=17.11±5.97 ml O2.kg-1.min-1; SSE=17.15±4.99 ml O2.kg-1.min-1 vs measured VO2max=26.67±3.53 ml O2.kg-1.min-1 (p < 0.001, and low correlation coeficients (r=0.488 and 0.471 between predicted and measured VO2max were observed. The equations presented high constant error (-9.56 and –9.53 ml O2.kg-1.min-1, with only 16.7% of agreement between the methods. Therefore, the RFWT was reliable, however, not valid for

  11. Mirroring the self: testing neurophysiological correlates of disturbed self-experience in schizophrenia spectrum.

    Science.gov (United States)

    Sestito, Mariateresa; Raballo, Andrea; Umiltà, Maria Alessandra; Leuci, Emanuela; Tonna, Matteo; Fortunati, Renata; De Paola, Giancarlo; Amore, Mario; Maggini, Carlo; Gallese, Vittorio

    2015-01-01

    Self-disorders (SDs) have been described as a core schizophrenia spectrum vulnerability phenotype, both in classic and contemporary psychopathological literature. However, such a core phenotype has not yet been investigated adopting a trans-domain approach that combines the phenomenological and the neurophysiological levels of analysis. The aim of this study is to investigate the relation between SDs and subtle, schizophrenia-specific impairments of emotional resonance that are supposed to reflect abnormalities in the mirror neurons mechanism. Specifically, we tested whether electromyographic response to emotional stimuli (i.e. a proxy for subtle changes in facial mimicry and related motor resonance mechanisms) would predict the occurrence of anomalous subjective experiences (i.e. SDs). Eighteen schizophrenia spectrum (SzSp) patients underwent a comprehensive psychopathological examination and were contextually tested with a multimodal paradigm, recording facial electromyographic activity of muscles in response to positive and negative emotional stimuli. Experiential anomalies were explored with the Bonn Scale for the Assessment of Basic Symptoms (BSABS) and then condensed into rational subscales mapping SzSp anomalous self-experiences. SzSp patients showed an imbalance in emotional motor resonance with a selective bias toward negative stimuli, as well as a multisensory integration impairment. Multiple regression analysis showed that electromyographic facial reactions in response to negative stimuli presented in auditory modality specifically and strongly correlated with SD subscore. The study confirms the potential of SDs as target phenotype for neurobiological research and encourages research into disturbed motor/emotional resonance as possible body-level correlate of disturbed subjective experiences in SzSp.

  12. Mechanical shape correlation : a novel integrated digital image correlation approach

    NARCIS (Netherlands)

    Kleinendorst, S.M.; Hoefnagels, J.P.M.; Geers, M.G.D.; Lamberti, L.; Lin, M.-T.; Furlong, C.; Sciammarella, C.

    2018-01-01

    Mechanical Shape Correlation (MSC) is a novel integrated digital image correlation technique, used to determine the optimal set of constitutive parameters to describe the experimentally observed mechanical behavior of a test specimen, based on digital images taken during the experiment. In contrast

  13. Strength and deformability of hollow concrete blocks: correlation of block and cylindrical sample test results

    Directory of Open Access Journals (Sweden)

    C. S. Barbosa

    Full Text Available This paper deals with correlations among mechanical properties of hollow blocks and those of concrete used to make them. Concrete hollow blocks and test samples were moulded with plastic consistency concrete, to assure the same material in all cases, in three diferente levels of strength (nominally 10 N/mm², 20 N/mm² and 30 N/mm². The mechanical properties and structural behaviour in axial compression and tension tests were determined by standard tests in blocks and cylinders. Stress and strain analyses were made based on concrete’s modulus of elasticity obtained in the sample tests as well as on measured strain in the blocks’ face-shells and webs. A peculiar stress-strain analysis, based on the superposition of effects, provided an estimation of the block load capacity based on its deformations. In addition, a tentative method to preview the block deformability from the concrete mechanical properties is described and tested. This analysis is a part of a broader research that aims to support a detailed structural analysis of blocks, prisms and masonry constructions.

  14. HBV and HCV test uptake and correlates among men who have sex with men in China: a nationwide cross-sectional online survey.

    Science.gov (United States)

    Fitzpatrick, Thomas; Pan, Stephen W; Tang, Weiming; Guo, Wilson; Tucker, Joseph D

    2018-05-19

    Hepatitis B virus (HBV) and hepatitis C virus (HCV) cause substantial morbidity and mortality in low-income and middle-income countries, including China. WHO guidelines recommend men who have sex with men (MSM) receive HBV and HCV screening. The purpose of this study was to determine the proportion of MSM in China who have HBV and HCV tested and identify correlates of test uptake. We conducted an online cross-sectional survey of young MSM in China. Respondents were asked to report previous HBV and HCV testing, sociodemographic information, sexual risk factors for hepatitis infection, other STI testing and primary care physician (PCP) status. Associations were analysed by logistic regression. 503 eligible MSM completed the survey. 41.0% (206/503) of MSM had HCV tested, and 38.2% (60/157) of MSM with no or uncertain HBV vaccination had HBV tested. In multivariate analysis, HCV testing was correlated with HBV testing (adjusted OR (aOR) 22.98, 95% CI 12.11 to 43.60), HIV testing (aOR 3.64, 95% CI 1.92 to 6.91), HIV-positive status (aOR 1.78, 95% CI 1.07 to 2.98) and having a PCP (aOR 2.40, 95% CI 1.44 to 3.98). Among MSM with no or uncertain HBV vaccination, HBV testing was correlated with HCV testing (aOR 80.85, 95% CI 20.80 to 314.33), HIV testing (aOR 5.26, 95% CI 1.81 to 15.28), HIV-positive status (aOR 3.00, 95% CI 1.22 to 7.37) and having a PCP (aOR 2.69, 95% CI 1.00 to 7.26). Our data suggest many young MSM in China have not received hepatitis testing. HCV testing rates were lower than those recently reported among MSM in Australia and the USA. The strong correlation between HBV and HCV testing suggests bundled testing interventions may be useful for MSM in China. Men with a PCP were more likely to have received hepatitis testing, consistent with literature demonstrating the importance of primary care in expanding access to testing. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No

  15. Initial experience of correlating parameters of intravoxel incoherent motion and dynamic contrast-enhanced magnetic resonance imaging at 3.0 T in nasopharyngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Qian-Jun; Zhang, Shui-Xing; Chen, Wen-Bo; Liang, Long; Zhou, Zheng-Gen; Liu, Zai-Yi; Zeng, Qiong-Xin; Liang, Chang-Hong [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Radiology, Guangzhou, Guangdong Province (China); Qiu, Qian-Hui [Guangdong General Hospital/Guangdong Academy of Medical Sciences, Department of Otolaryngology, Guangzhou, Guangdong Province (China)

    2014-12-15

    To determine the correlation between intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) parameters. Thirty-eight newly diagnosed NPC patients were prospectively enrolled. Diffusion-weighted images (DWI) at 13 b-values were acquired using a 3.0-T MRI system. IVIM parameters including the pure molecular diffusion (D), perfusion-related diffusion (D*), perfusion fraction (f), DCE-MRI parameters including maximum slope of increase (MSI), enhancement amplitude (EA) and enhancement ratio (ER) were calculated by two investigators independently. Intra- and interobserver agreement were evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Relationships between IVIM and DCE-MRI parameters were evaluated by calculation of Spearman's correlation coefficient. Intra- and interobserver reproducibility were excellent to relatively good (ICC = 0.887-0.997; narrow width of 95 % limits of agreement). The highest correlation was observed between f and EA (r = 0.633, P < 0.001), with a strong correlation between f and MSI (r = 0.598, P = 0.001). No correlation was observed between f and ER (r = -0.162; P = 0.421) or D* and DCE parameters (r = 0.125-0.307; P > 0.119). This study suggests IVIM perfusion imaging using 3.0-T MRI is feasible in NPC, and f correlates significantly with EA and MSI. (orig.)

  16. Testing the correlation of fragmented pollen records of the middle and late Pleistocene temperate stages

    DEFF Research Database (Denmark)

    Kuneš, Petr; Odgaard, Bent Vad

    Quaternary temperate stages have long been described based on changing pollen abundances of various tree taxa in lacustrine sediments. Later, attempts have been made to assign such biostratigraphic units to distinct marine isotope stages (MIS). Existing continuous chronosequences from Southern...... records depends on site-to-site correlations. This comparison has often been performed on a visual basis, lacking clearly defined protocols and statements of underlying assumptions. Here I test the correlation of well and poorly known pollen records of the middle- and late-Pleistocene temperate stages...... from Northern-Central Europe and evaluate the usefulness of several numerical techniques. TWINSPAN analysis identifies groups of temperate stages based on presence/absence of their indicative taxa and may be useful for distinguishing between older and younger interglacials. Site-to-site sequence...

  17. Reliability of a computer software angle tool for measuring spine and pelvic flexibility during the sit-and-reach test.

    Science.gov (United States)

    Mier, Constance M; Shapiro, Belinda S

    2013-02-01

    The purpose of this study was to determine the reliability of a computer software angle tool that measures thoracic (T), lumbar (L), and pelvic (P) angles as a means of evaluating spine and pelvic flexibility during the sit-and-reach (SR) test. Thirty adults performed the SR twice on separate days. The SR test was captured on video and later analyzed for T, L, and P angles using the computer software angle tool. During the test, 3 markers were placed over T1, T12, and L5 vertebrae to identify T, L, and P angles. Intraclass correlation coefficient (ICC) indicated a very high internal consistency (between trials) for T, L, and P angles (0.95-0.99); thus, the average of trials was used for test-retest (between days) reliability. Mean (±SD) values did not differ between days for T (51.0 ± 14.3 vs. 52.3 ± 16.2°), L (23.9 ± 7.1 vs. 23.0 ± 6.9°), or P (98.4 ± 15.6 vs. 98.3 ± 14.7°) angles. Test-retest reliability (ICC) was high for T (0.96) and P (0.97) angles and moderate for L angle (0.84). Both intrarater and interrater reliabilities were high for T (0.95, 0.94) and P (0.97, 0.97) angles and moderate for L angle (0.87, 0.82). Thus, the computer software angle tool is a highly objective method for assessing spine and pelvic flexibility during a video-captured SR test.

  18. Reliability, standard error, and minimum detectable change of clinical pressure pain threshold testing in people with and without acute neck pain.

    Science.gov (United States)

    Walton, David M; Macdermid, Joy C; Nielson, Warren; Teasell, Robert W; Chiasson, Marco; Brown, Lauren

    2011-09-01

    Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94-0.97), interrater reliability was substantial to near perfect (ICC = 0.79-0.90), and test-retest reliability was substantial (ICC = 0.76-0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain.

  19. Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarthritis.

    Science.gov (United States)

    Baert, Isabel A C; Lluch, Enrique; Struyf, Thomas; Peeters, Greta; Van Oosterwijck, Sophie; Tuynman, Joanna; Rufai, Salim; Struyf, Filip

    2018-06-01

    The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Cross-sectional test-retest design. Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correlation coefficients (ICCs; model 2,1), standard error of measurement (SEM) and minimal detectable change with 95% confidence bounds (MDC 95 ) were calculated. For KJPS, results showed good to excellent test-retest agreement (ICCs 0.70-0.95 in KOA patients; ICCs 0.65-0.85 in healthy controls). A 2° measurement error (SEM 1°) was reported when measuring KJPS in multiple test positions and calculating mean repositioning error. Testing KOA patients pre and post therapy a repositioning error larger than 4° (MDC 95 ) is needed to consider true change. Measuring KFS using handheld dynamometry showed poor to fair interrater and poor to excellent intrarater reliability in subjects with and without KOA. Measuring KJPS in multiple test positions using an analogue inclinometer and calculating mean repositioning error is reliable and can be used in clinical practice. We do not recommend the use of the KFS test to clinicians. Further research is required to establish diagnostic accuracy and validity of our KJPS test in larger knee pain populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Correlation analysis between pulmonary function test parameters and CT image parameters of emphysema

    Science.gov (United States)

    Liu, Cheng-Pei; Li, Chia-Chen; Yu, Chong-Jen; Chang, Yeun-Chung; Wang, Cheng-Yi; Yu, Wen-Kuang; Chen, Chung-Ming

    2016-03-01

    Conventionally, diagnosis and severity classification of Chronic Obstructive Pulmonary Disease (COPD) are usually based on the pulmonary function tests (PFTs). To reduce the need of PFT for the diagnosis of COPD, this paper proposes a correlation model between the lung CT images and the crucial index of the PFT, FEV1/FVC, a severity index of COPD distinguishing a normal subject from a COPD patient. A new lung CT image index, Mirage Index (MI), has been developed to describe the severity of COPD primarily with emphysema disease. Unlike conventional Pixel Index (PI) which takes into account all voxels with HU values less than -950, the proposed approach modeled these voxels by different sizes of bullae balls and defines MI as a weighted sum of the percentages of the bullae balls of different size classes and locations in a lung. For evaluation of the efficacy of the proposed model, 45 emphysema subjects of different severity were involved in this study. In comparison with the conventional index, PI, the correlation between MI and FEV1/FVC is -0.75+/-0.08, which substantially outperforms the correlation between PI and FEV1/FVC, i.e., -0.63+/-0.11. Moreover, we have shown that the emphysematous lesion areas constituted by small bullae balls are basically irrelevant to FEV1/FVC. The statistical analysis and special case study results show that MI can offer better assessment in different analyses.