WorldWideScience

Sample records for test center volume

  1. SOAC - State-of-the-Art Car Engineering Tests at Department of Transportation High Speed Ground Test Center : Volume 2. Performance Tests.

    Science.gov (United States)

    1975-01-01

    The six-volume report presents the technical methodology, data samples, and results of tests conducted on the SOAC on the Rail Transit Test Track at the High Speed Ground Test Center in Pueblo, Colorado during the period April to July 1973. The Test ...

  2. Survival in pediatric lung transplantation: The effect of center volume and expertise.

    Science.gov (United States)

    Khan, Muhammad S; Zhang, Wei; Taylor, Rachel A; Dean McKenzie, E; Mallory, George B; Schecter, Marc G; Morales, David L S; Heinle, Jeffrey S; Adachi, Iki

    2015-08-01

    Institutional operative volume has been shown to impact outcomes of various procedures including lung transplantation (LTx). We sought to determine whether this holds true with pediatric LTx by comparing outcomes of adult centers (with larger overall volume) to those of pediatric centers (with smaller volume but more pediatric-specific experience). A retrospective analysis of the Organ Procurement and Transplant Network data was performed. Centers were categorized as either adult (LTx volume predominantly in adult patients), high-volume pediatric (HVP, ≥4 LTxs/year), or low-volume pediatric (LVP, HVP 3 [5%], LVP 8 [13%]). Although adult centers had larger overall LTx volume, their pediatric experiences were severely limited (median 1/year). In younger children, HVP centers were significantly better than LVP centers for patient survival (half-life: 7.3 vs 2.9 years, p = 0.002). Similarly, in older children and adolescents, HVP centers were significantly better than adult centers for patient survival (half-life: 4.6 vs 2.5 years, p = 0.001). Of note, even LVP centers tended to have longer patient survival than adult centers (p = 0.064). Multivariable analysis identified adult centers as an independent risk factor for graft failure (hazard ratio: 1.5, p < 0.001) as with LVP (hazard ratio: 1.3, p = 0.0078). Despite larger overall clinical volume, outcomes among pediatric LTx recipients in adult centers are not superior to those of pediatric centers. Not only center volume but pediatric-specific experience has an impact on outcomes in pediatric LTx. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  3. Case mix-adjusted cost of colectomy at low-, middle-, and high-volume academic centers.

    Science.gov (United States)

    Chang, Alex L; Kim, Young; Ertel, Audrey E; Hoehn, Richard S; Wima, Koffi; Abbott, Daniel E; Shah, Shimul A

    2017-05-01

    Efforts to regionalize surgery based on thresholds in procedure volume may have consequences on the cost of health care delivery. This study aims to delineate the relationship between hospital volume, case mix, and variability in the cost of operative intervention using colectomy as the model. All patients undergoing colectomy (n = 90,583) at 183 academic hospitals from 2009-2012 in The University HealthSystems Consortium Database were studied. Patient and procedure details were used to generate a case mix-adjusted predictive model of total direct costs. Observed to expected costs for each center were evaluated between centers based on overall procedure volume. Patient and procedure characteristics were significantly different between volume tertiles. Observed costs at high-volume centers were less than at middle- and low-volume centers. According to our predictive model, high-volume centers cared for a less expensive case mix than middle- and low-volume centers ($12,786 vs $13,236 and $14,497, P case mix at low-volume centers, which may lead to perceived poor performance at these centers. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Trends in laboratory test volumes for Medicare Part B reimbursements, 2000-2010.

    Science.gov (United States)

    Shahangian, Shahram; Alspach, Todd D; Astles, J Rex; Yesupriya, Ajay; Dettwyler, William K

    2014-02-01

    Changes in reimbursements for clinical laboratory testing may help us assess the effect of various variables, such as testing recommendations, market forces, changes in testing technology, and changes in clinical or laboratory practices, and provide information that can influence health care and public health policy decisions. To date, however, there has been no report, to our knowledge, of longitudinal trends in national laboratory test use. To evaluate Medicare Part B-reimbursed volumes of selected laboratory tests per 10,000 enrollees from 2000 through 2010. Laboratory test reimbursement volumes per 10,000 enrollees in Medicare Part B were obtained from the Centers for Medicare & Medicaid Services (Baltimore, Maryland). The ratio of the most recent (2010) reimbursed test volume per 10,000 Medicare enrollees, divided by the oldest data (usually 2000) during this decade, called the volume ratio, was used to measure trends in test reimbursement. Laboratory tests with a reimbursement claim frequency of at least 10 per 10,000 Medicare enrollees in 2010 were selected, provided there was more than a 50% change in test reimbursement volume during the 2000-2010 decade. We combined the reimbursed test volumes for the few tests that were listed under more than one code in the Current Procedural Terminology (American Medical Association, Chicago, Illinois). A 2-sided Poisson regression, adjusted for potential overdispersion, was used to determine P values for the trend; trends were considered significant at P reimbursement volumes were electrolytes, digoxin, carbamazepine, phenytoin, and lithium, with volume ratios ranging from 0.27 to 0.64 (P reimbursement volumes were meprobamate, opiates, methadone, phencyclidine, amphetamines, cocaine, and vitamin D, with volume ratios ranging from 83 to 1510 (P reimbursement volumes increased for most of the selected tests, other tests exhibited statistically significant downward trends in annual reimbursement volumes. The observed

  5. Going the Extra Mile: Improved Survival for Pancreatic Cancer Patients Traveling to High-volume Centers.

    Science.gov (United States)

    Lidsky, Michael E; Sun, Zhifei; Nussbaum, Daniel P; Adam, Mohamed A; Speicher, Paul J; Blazer, Dan G

    2017-08-01

    This study compares outcomes following pancreaticoduodenectomy (PD) for patients treated at local, low-volume centers and those traveling to high-volume centers. Although outcomes for PD are superior at high-volume institutions, not all patients live in proximity to major medical centers. Theoretical advantages for undergoing surgery locally exist. The 1998 to 2012 National Cancer Data Base was queried for T1-3N0-1M0 pancreatic adenocarcinoma patients who underwent PD. Travel distances to treatment centers were calculated. Overlaying the upper and lower quartiles of travel distance with institutional volume established short travel/low-volume (ST/LV) and long travel/high-volume (LT/HV) cohorts. Overall survival was evaluated. Of 7086 patients, 773 ST/LV patients traveled ≤6.3 (median 3.2) miles to centers performing ≤3.3 PDs yearly, and 758 LT/HV patients traveled ≥45 (median 97.3) miles to centers performing ≥16 PDs yearly. LT/HV patients had higher stage disease (P travel to a high-volume center remained associated with reduced long-term mortality (hazard ratio 0.75, P travel burden, patients treated at high-volume centers had improved perioperative outcomes, short-term mortality, and overall survival. These data support ongoing efforts to centralize care for patients undergoing PD.

  6. TOP 01-1-011B Vehicle Test Facilities at Aberdeen Test Center and Yuma Test Center

    Science.gov (United States)

    2017-12-12

    Test Center 400 Colleran Road Aberdeen Proving Ground, MD 21005-5059 U.S. Army Yuma Proving Ground Yuma Test Center 301 C. Street Yuma, AZ...22 2.6 Munson Test Area (MTA) ..................................................... 24 2.7 Land Vehicle Maintenance Facility...127 3.6 Maintenance Facilities ........................................................... 143

  7. SPORT AND EXERCISE PHYSIOLOGY TESTING Volume one: Sport Testing Volume two: Exercise and Clinical Testing

    Directory of Open Access Journals (Sweden)

    Edward M. Winter

    2007-03-01

    Full Text Available DESCRIPTION The objective of the book is to discuss the theoretical and practical aspects of physiological testing in exercise and sports which is essential to evaluate and monitor developing exercise performance for athletes and public health, and improving quality of life for patients.A board of leading sport and exercise physiologists and scientists are gathered to discuss physiological assessments that have proven validity and reliability, both in sport and health relevant issues. Incidentally, it updates the reader about the current subjects of physiological exertion testing in both research and clinical procedures. Both volumes individually cover the increasing number of available research and review publications, and theoretical explanations are supported by practical examples. A step-by-step and/or checklist method is used in appropriate sections which make the guides more user-friendly than most. PURPOSE The first volume is designed to help readers develop an understanding of the essential concepts of sport specific testing whereas the second volume aims at making the exercise and clinical specific testing comprehensible, dealing with both technical terms and the theories underlying the importance of these tests. AUDIENCE As Guidelines books of the British Association of Sport and Exercise Sciences, it will be of interest to a wide range of students, researchers and practitioners in the sport and exercise disciplines whether they work in the laboratory or in the field. FEATURES The first volume features immediate practical requirements particularly in sport testing. It is composed of five parts with detailed sub-sections in all of them. The topics of the parts are: i general principles, ii methodological issues, iii general procedures, iv sport specific procedures, v special populations.The second volume is also presented in five parts, again with sub-sections in all of them, but considering the requirements in clinical and exercise

  8. High call volume at poison control centers: identification and implications for communication.

    Science.gov (United States)

    Caravati, E M; Latimer, S; Reblin, M; Bennett, H K W; Cummins, M R; Crouch, B I; Ellington, L

    2012-09-01

    High volume surges in health care are uncommon and unpredictable events. Their impact on health system performance and capacity is difficult to study. To identify time periods that exhibited very busy conditions at a poison control center and to determine whether cases and communication during high volume call periods are different from cases during low volume periods. Call data from a US poison control center over twelve consecutive months was collected via a call logger and an electronic case database (Toxicall®).Variables evaluated for high call volume conditions were: (1) call duration; (2) number of cases; and (3) number of calls per staff member per 30 minute period. Statistical analyses identified peak periods as busier than 99% of all other 30 minute time periods and low volume periods as slower than 70% of all other 30 minute periods. Case and communication characteristics of high volume and low volume calls were compared using logistic regression. A total of 65,364 incoming calls occurred over 12 months. One hundred high call volume and 4885 low call volume 30 minute periods were identified. High volume periods were more common between 1500 and 2300 hours and during the winter months. Coded verbal communication data were evaluated for 42 high volume and 296 low volume calls. The mean (standard deviation) call length of these calls during high volume and low volume periods was 3 minutes 27 seconds (1 minute 46 seconds) and 3 minutes 57 seconds (2 minutes 11 seconds), respectively. Regression analyses revealed a trend for fewer overall verbal statements and fewer staff questions during peak periods, but no other significant differences for staff-caller communication behaviors were found. Peak activity for poison center call volume can be identified by statistical modeling. Calls during high volume periods were similar to low volume calls. Communication was more concise yet staff was able to maintain a good rapport with callers during busy call periods

  9. Engineer Research and Development Center's Materials Testing Center (MTC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Engineer Research and Development Center's Materials Testing Center (MTC) is committed to quality testing and inspection services that are delivered on time and...

  10. Electrolysis activities at FCH Test Center

    DEFF Research Database (Denmark)

    Ravn Nielsen, Eva; Nygaard, Frederik Berg

    FCH Test Center for fuel cell and hydrogen technologies was established in 2010 at Risø DTU in Denmark. Today, the test center is part of DTU Energy Conversion. The center gives industry access to advanced testing and demonstration of components and systems. A number of national projects and EU...... projects regarding water electrolysis involve FCH Test Center as a partner. This presentation gives an overview of the activities....

  11. Test Control Center (TCC)

    Data.gov (United States)

    Federal Laboratory Consortium — The Test Control Center (TCC) provides a consolidated facility for planning, coordinating, controlling, monitoring, and analyzing distributed test events. ,The TCC...

  12. Is the Distance Worth It? Patients With Rectal Cancer Traveling to High-Volume Centers Experience Improved Outcomes.

    Science.gov (United States)

    Xu, Zhaomin; Becerra, Adan Z; Justiniano, Carla F; Boodry, Courtney I; Aquina, Christopher T; Swanger, Alex A; Temple, Larissa K; Fleming, Fergal J

    2017-12-01

    It is unclear whether traveling long distances to high-volume centers would compensate for travel burden among patients undergoing rectal cancer resection. The purpose of this study was to determine whether operative volume outweighs the advantages of being treated locally by comparing the outcomes of patients with rectal cancer treated at local, low-volume centers versus far, high-volume centers. This was a population-based study. The National Cancer Database was queried for patients with rectal cancer. Patients with stage II or III rectal cancer who underwent surgical resection between 2006 and 2012 were included. The outcomes of interest were margins, lymph node yield, receipt of neoadjuvant chemoradiation, adjuvant chemotherapy, readmission within 30 days, 30-day and 90-day mortality, and 5-year overall survival. A total of 18,605 patients met inclusion criteria; 2067 patients were in the long-distance/high-volume group and 1362 in the short-distance/low-volume group. The median travel distance was 62.6 miles for the long-distance/high-volume group and 2.3 miles for the short-distance/low-volume group. Patients who were younger, white, privately insured, and stage III were more likely to have traveled to a high-volume center. When controlled for patient factors, stage, and hospital factors, patients in the short-distance/low-volume group had lower odds of a lymph node yield ≥12 (OR = 0.51) and neoadjuvant chemoradiation (OR = 0.67) and higher 30-day (OR = 3.38) and 90-day mortality (OR = 2.07) compared with those in the long-distance/high-volume group. The short-distance/low-volume group had a 34% high risk of overall mortality at 5 years compared with the long-distance/high-volume group. We lacked data regarding patient and physician decision making and surgeon-specific factors. Our results indicate that when controlled for patient, tumor, and hospital factors, patients who traveled a long distance to a high-volume center had improved lymph node yield

  13. Study on magnetic field mapping within cylindrical center volume of general magnet

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Li; Lee, Sang Jin [Uiduk University, Gyeongju (Korea, Republic of)

    2016-06-15

    For the magnetic field analysis or design, it is important to know the behavior of the magnetic field in an interesting space. Magnetic field mapping becomes a useful tool for the study of magnetic field. In this paper, a numerical way for mapping the magnetic field within the cylindrical center volume of magnet is presented, based on the solution of the Laplace's equation in the cylindrical coordinate system. The expression of the magnetic field can be obtained by the magnetic flux density, which measured in the mapped volume. According to the form of the expression, the measurement points are arranged with the parallel cylindrical line (PCL) method. As example, the magnetic flux density generated by an electron cyclotron resonance ion source (ECRIS) magnet and a quadrupole magnet were mapped using the PCL method, respectively. The mapping results show the PCL arrangement method is feasible and convenience to map the magnetic field within a cylindrical center volume generated by the general magnet.

  14. The current status of emergency operations at a high-volume cancer center.

    Science.gov (United States)

    Komori, Koji; Kimura, Kenya; Kinoshita, Takashi; Ito, Seiji; Abe, Tetsuya; Senda, Yoshiki; Misawa, Kazunari; Ito, Yuichi; Uemura, Norihisa; Natsume, Seiji; Kawai, Ryosuke; Kawakami, Jiro; Asano, Tomonari; Iwata, Yoshinori; Kurahashi, Shintaro; Tsutsuyama, Masayuki; Shigeyoshi, Itaru; Shimizu, Yasuhiro

    2014-01-01

    This study aimed to assess the pathogenic causes, clinical conditions, surgical procedures, in-hospital mortality, and operative death associated with emergency operations at a high-volume cancer center. Although many reports have described the contents, operative procedures, and prognosis of elective surgeries in high-volume cancer centers, emergency operations have not been studied in sufficient detail. We retrospectively enrolled 28 consecutive patients who underwent emergency surgery. Cases involving operative complications were excluded. The following surgical procedures were performed during emergency operations: closure in 3 cases (10.7%), diversion in 22 cases (78.6%), ileus treatment in 2 cases (7.1%), and hemostasis in 1 case (3.6%). Closure alone was performed only once for peritonitis. Diversion was performed in 17 cases (77.3%) of peritonitis, 4 cases (18.2%) of stenosis of the gastrointestinal tract, and 1 case (4.5%) of bleeding. There was a significant overall difference (P = 0.001). The frequency of emergency operations was very low at a high-volume cancer center. However, the recent shift in treatment approaches toward nonoperative techniques may enhance the status of emergency surgical procedures. The results presented in this study will help prepare for emergency situations and resolve them as quickly and efficiently as possible.

  15. The Testing Behind The Test Facility: The Acoustic Design of the NASA Glenn Research Center's World-Class Reverberant Acoustic Test Facility

    Science.gov (United States)

    Hozman, Aron D.; Hughes, William O.; McNelis, Mark E.; McNelis, Anne M.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA's space exploration program. The large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 cu ft in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world's known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada's acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama, USA. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic design and subsequent on-going construction.

  16. Alternative occupied volume integrity (OVI) tests and analyses.

    Science.gov (United States)

    2013-10-01

    FRA, supported by the Volpe Center, conducted research on alternative methods of evaluating occupied volume integrity (OVI) in passenger railcars. Guided by this research, an alternative methodology for evaluating OVI that ensures an equivalent or gr...

  17. Final Report Feasibility Study for the California Wave Energy Test Center (CalWavesm) - Volume #2 - Appendices #16-17

    Energy Technology Data Exchange (ETDEWEB)

    Dooher, Brendan [Pacific Gas and Electric Company, San Ramon, CA (United States). Applied Technical Services; Toman, William I. [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States). Inst. of Advanced Technology and Public Policy; Davy, Doug M. [CH2M Hill Engineers, Inc., Sacramento, CA (United States); Blakslee, Samuel N. [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States)

    2017-07-31

    The California Wave Energy Test Center (CalWave) Feasibility Study project was funded over multiple phases by the Department of Energy to perform an interdisciplinary feasibility assessment to analyze the engineering, permitting, and stakeholder requirements to establish an open water, fully energetic, grid connected, wave energy test center off the coast of California for the purposes of advancing U.S. wave energy research, development, and testing capabilities. Work under this grant included wave energy resource characterization, grid impact and interconnection requirements, port infrastructure and maritime industry capability/suitability to accommodate the industry at research, demonstration and commercial scale, and macro and micro siting considerations. CalWave Phase I performed a macro-siting and down-selection process focusing on two potential test sites in California: Humboldt Bay and Vandenberg Air Force Base. This work resulted in the Vandenberg Air Force Base site being chosen as the most favorable site based on a peer reviewed criteria matrix. CalWave Phase II focused on four siting location alternatives along the Vandenberg Air Force Base coastline and culminated with a final siting down-selection. Key outcomes from this work include completion of preliminary engineering and systems integration work, a robust turnkey cost estimate, shoreside and subsea hazards assessment, storm wave analysis, lessons learned reports from several maritime disciplines, test center benchmarking as compared to existing international test sites, analysis of existing applicable environmental literature, the completion of a preliminary regulatory, permitting and licensing roadmap, robust interaction and engagement with state and federal regulatory agency personnel and local stakeholders, and the population of a Draft Federal Energy Regulatory Commission (FERC) Preliminary Application Document (PAD). Analysis of existing offshore oil and gas infrastructure was also performed

  18. Nuclear Fuel Recovery and Recycling Center. License application, PSAR, volume 3

    International Nuclear Information System (INIS)

    1976-01-01

    Volume 3 comprises Chapter 5 which provides descriptive information on Nuclear Fuel Recovery and Recycling Center buildings and other facilities, including their locations. The design features discussed include those used to withstand environmental and accidental forces and to insure radiological protection

  19. Comparison of the outcomes for laparoscopic gastrectomy performed by the same surgeon between a low-volume hospital and a high-volume center.

    Science.gov (United States)

    Kim, Min Gyu; Kwon, Sung Joon

    2014-05-01

    The volume-outcome relationship in laparoscopic surgery is controversial. This study was designed to identify differences in laparoscopic gastrectomy outcomes between a low-volume hospital and a high-volume center and to provide guidelines for overcoming the problems associated with a low-volume hospital. From April 2009 to November 2012, one surgeon performed 134 totally laparoscopic distal gastrectomies (TLDGs) at a high-volume center (HVC; ASAN Medical Center) and at a low-volume hospital (LVH; Hanyang University Guri Hospital). All laparoscopically assisted gastrectomies were excluded from this study. During the early period of laparoscopic gastrectomy at the low-volume hospital, TLDG with Roux-en-Y gastrojejunostomy (RYGJ) was performed according to the surgeon's choice. The reconstruction method was classified as gastroduodenostomy (GD) or RYGJ. Early surgical outcomes achieved at the LVH were investigated and compared with those obtained at the HVC. The early surgical outcomes differed significantly between the two hospitals. In particular, the postoperative complication rate for the patients who underwent TLDG RYGJ at the LVH was higher than at the HVC (LVH 15.4 % vs. HVC 0 %; p = 0.037). Furthermore, significant differences were observed in the mean operation time (TLDG GD: LVH 141.0 min vs. HVC 117.4 min, p = 0.001; TLDG RYGJ: LVH 186.3 min vs. HVC 134.6 min, p = 0.009) and length of hospital stay (TLDG GD: LVH 8.1 days vs. HVC 7.2 days, p = 0.044; TLDG RYGJ: LVH 11.5 day vs. HVC 6.8 day, p = 0.009). Although all the operations were performed by one experienced surgeon, the early surgical outcomes differed significantly between the low- and high-volume hospitals. Low-volume hospitals often lack well-trained surgical professionals such as first assistants and scrub nurses. Therefore, the authors recommend that a surgeon who works at an LVH should assess potential personnel shortages and find a solution before operating.

  20. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  1. Strategy for Alternative Occupant Volume Testing

    Science.gov (United States)

    2009-10-20

    This paper describes plans for a series of quasi-static : compression tests of rail passenger equipment. These tests are : designed to evaluate the strength of the occupant volume under : static loading conditions. The research plan includes a detail...

  2. Graded Exercise Testing in a Pediatric Weight Management Center: The DeVos Protocol.

    Science.gov (United States)

    Eisenmann, Joey C; Guseman, Emily Hill; Morrison, Kyle; Tucker, Jared; Smith, Lucie; Stratbucker, William

    2015-12-01

    In this article, we describe a protocol used to test the functional capacity of the obese pediatric patient and describe the peak oxygen consumption (VO2peak) of patients seeking treatment at a pediatric weight management center. One hundred eleven (mean age, 12.5 ± 3.0 years) patients performed a multistage exercise test on a treadmill, of which 90 (81%) met end-test criteria and provided valid VO2peak data. Peak VO2 was expressed: (1) in absolute terms (L·min(-1)); (2) as the ratio of the volume of oxygen consumed per minute relative to total body mass (mL·kg(-1)·min(-1)); and (3) as the ratio of the volume of oxygen consumed per minute relative to fat-free mass (mL·FFM·kg(-1)·min(-1)). Mean BMI z-score was 2.4 ± 0.3 and the mean percent body fat was 36.5 ± 9.7%. Absolute VO2peak (L·min(-1)) was significantly different between sexes; however, relative values were similar between sexes. Mean VO2peak was 25.7 ± 4.8 mL·kg(-1)·min(-1) with a range of 13.5-36.7 mL·kg(-1)·min(-1). Obese youth seeking treatment at a stage 3 pediatric weight management center exhibit low VO2peak. The protocol outlined here should serve as a model for similar programs interested in the submaximal and peak responses to exercise in obese pediatric patients.

  3. Update on alternative occupant volume testing

    Science.gov (United States)

    2010-04-27

    This paper describes the conduct of the first of a series of quasi-static compression tests of rail passenger equipment being done to examine occupant volume strength. Budd Pioneer car 244 has been chosen as the test article for examination of altern...

  4. Engineering test facility design center

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The vehicle by which the fusion program would move into the engineering testing phase of fusion power development is designated the Engineering Test Facility (ETF). The ETF would provide a test bed for reactor components in the fusion environment. In order to initiate preliminary planning for the ETF decision, the Office of Fusion Energy established the ETF Design Center activity to prepare the design of the ETF. This section describes the status of this design

  5. Pad-weighing test performed with standardized bladder volume

    DEFF Research Database (Denmark)

    Lose, G; Rosenkilde, P; Gammelgaard, J

    1988-01-01

    The result of the one-hour pad-weighing test proposed by the International Continence Society has been demonstrated to depend on the urine load during the test. To increase reproducibility of the pad-weighing test by minimizing the influence of variation in urine load the test was done with a sta...... to +/- 24 g between two tests. It is concluded that this setup (i.e., standardized bladder volume) of the one-hour pad-weighing test allows for a more reliable assessment of urinary incontinence for quantitative purposes....... with a standardized bladder volume (50% of the cystometric bladder capacity). Twenty-five female patients with stress or mixed incontinence underwent two separate tests. Test-retest results were highly correlated (r = 0.97, p less than 0.001). Nonetheless, analysis of test-retest differences revealed a variation up...

  6. Renewable Resources: a national catalog of model projects. Volume 3. Southern Solar Energy Center Region

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-07-01

    This compilation of diverse conservation and renewable energy projects across the United States was prepared through the enthusiastic participation of solar and alternate energy groups from every state and region. Compiled and edited by the Center for Renewable Resources, these projects reflect many levels of innovation and technical expertise. In many cases, a critique analysis is presented of how projects performed and of the institutional conditions associated with their success or failure. Some 2000 projects are included in this compilation; most have worked, some have not. Information about all is presented to aid learning from these experiences. The four volumes in this set are arranged in state sections by geographic region, coinciding with the four Regional Solar Energy Centers. The table of contents is organized by project category so that maximum cross-referencing may be obtained. This volume includes information on the Southern Solar Energy Center Region. (WHK)

  7. Renewable Resources: a national catalog of model projects. Volume 1. Northeast Solar Energy Center Region

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-07-01

    This compilation of diverse conservation and renewable energy projects across the United States was prepared through the enthusiastic participation of solar and alternate energy groups from every state and region. Compiled and edited by the Center for Renewable Resources, these projects reflect many levels of innovation and technical expertise. In many cases, a critique analysis is presented of how projects performed and of the institutional conditions associated with their success or failure. Some 2000 projects are included in this compilation; most have worked, some have not. Information about all is presented to aid learning from these experiences. The four volumes in this set are arranged in state sections by geographic region, coinciding with the four Regional Solar Energy Centers. The table of contents is organized by project category so that maximum cross-referencing may be obtained. This volume includes information on the Northeast Solar Energy Center Region. (WHK).

  8. Volume changes and electrostriction in the primary photoreactions of various photosynthetic systems: estimation of dielectric coefficient in bacterial reaction centers and of the observed volume changes with the Drude-Nernst equation.

    Science.gov (United States)

    Mauzerall, David; Hou, Jian-Min; Boichenko, Vladimir A

    2002-01-01

    Photoacoustics (PA) allows the determination of enthalpy and volume changes of photoreactions in photosynthetic reaction centers on the 0.1-10 mus time scale. These include the bacterial centers from Rb. sphaeroides, PS I and PS II centers from Synechocystis and in whole cells. In vitro and in vivo PA data on PS I and PS II revealed that both the volume change (-26 A(3)) and reaction enthalpy (-0.4 eV) in PS I are the same as those in the bacterial centers. However the volume change in PS II is small and the enthalpy far larger, -1 eV. Assigning the volume changes to electrostriction allows a coherent explanation of these observations. One can explain the large volume decrease in the bacterial centers with an effective dielectric coefficient of approximately 4. This is a unique approach to this parameter so important in estimation of protein energetics. The value of the volume contraction for PS I can only be explained if the acceptor is the super- cluster (Fe(4)S(4))(Cys(4)) with charge change from -1 to -2. The small volume change in PS II is explained by sub-mus electron transfer from Y(Z) anion to P(680) cation, in which charge is only moved from the Y(Z) anion to the Q(A) with no charge separation or with rapid proton transfer from oxidized Y(Z) to a polar region and thus very little change in electrostriction. At more acid pH equally rapid proton transfer from a neighboring histidine to a polar region may be caused by the electric field of the P(680) cation.

  9. Center-stabilized Yang-Mills Theory:Confinement and Large N Volume Independence

    International Nuclear Information System (INIS)

    Unsal, Mithat; Yaffe, Laurence G.

    2008-01-01

    We examine a double trace deformation of SU(N) Yang-Mills theory which, for large N and large volume, is equivalent to unmodified Yang-Mills theory up to O(1/N 2 ) corrections. In contrast to the unmodified theory, large N volume independence is valid in the deformed theory down to arbitrarily small volumes. The double trace deformation prevents the spontaneous breaking of center symmetry which would otherwise disrupt large N volume independence in small volumes. For small values of N, if the theory is formulated on R 3 x S 1 with a sufficiently small compactification size L, then an analytic treatment of the non-perturbative dynamics of the deformed theory is possible. In this regime, we show that the deformed Yang-Mills theory has a mass gap and exhibits linear confinement. Increasing the circumference L or number of colors N decreases the separation of scales on which the analytic treatment relies. However, there are no order parameters which distinguish the small and large radius regimes. Consequently, for small N the deformed theory provides a novel example of a locally four-dimensional pure gauge theory in which one has analytic control over confinement, while for large N it provides a simple fully reduced model for Yang-Mills theory. The construction is easily generalized to QCD and other QCD-like theories

  10. Center-stabilized Yang-Mills theory: Confinement and large N volume independence

    International Nuclear Information System (INIS)

    Uensal, Mithat; Yaffe, Laurence G.

    2008-01-01

    We examine a double trace deformation of SU(N) Yang-Mills theory which, for large N and large volume, is equivalent to unmodified Yang-Mills theory up to O(1/N 2 ) corrections. In contrast to the unmodified theory, large N volume independence is valid in the deformed theory down to arbitrarily small volumes. The double trace deformation prevents the spontaneous breaking of center symmetry which would otherwise disrupt large N volume independence in small volumes. For small values of N, if the theory is formulated on R 3 xS 1 with a sufficiently small compactification size L, then an analytic treatment of the nonperturbative dynamics of the deformed theory is possible. In this regime, we show that the deformed Yang-Mills theory has a mass gap and exhibits linear confinement. Increasing the circumference L or number of colors N decreases the separation of scales on which the analytic treatment relies. However, there are no order parameters which distinguish the small and large radius regimes. Consequently, for small N the deformed theory provides a novel example of a locally four-dimensional pure-gauge theory in which one has analytic control over confinement, while for large N it provides a simple fully reduced model for Yang-Mills theory. The construction is easily generalized to QCD and other QCD-like theories.

  11. Evolving progress in oncologic and operative outcomes for esophageal and junctional cancer: lessons from the experience of a high-volume center.

    LENUS (Irish Health Repository)

    Reynolds, John V

    2012-05-01

    Modern series from high-volume esophageal centers report an approximate 40% 5-year survival in patients treated with curative intent and postoperative mortality rates of less than 4%. An objective analysis of factors that underpin current benchmarks within high-volume centers has not been performed.

  12. Mimetic Theory for Cell-Centered Lagrangian Finite Volume Formulation on General Unstructured Grids

    Energy Technology Data Exchange (ETDEWEB)

    Sambasivan, Shiv Kumar [Los Alamos National Laboratory; Shashkov, Mikhail J. [Los Alamos National Laboratory; Burton, Donald E. [Los Alamos National Laboratory; Christon, Mark A. [Los Alamos National Laboratory

    2012-07-19

    A finite volume cell-centered Lagrangian scheme for solving large deformation problems is constructed based on the hypo-elastic model and using the mimetic theory. Rigorous analysis in the context of gas and solid dynamics, and arbitrary polygonal meshes, is presented to demonstrate the ability of cell-centered schemes in mimicking the continuum properties and principles at the discrete level. A new mimetic formulation based gradient evaluation technique and physics-based, frame independent and symmetry preserving slope limiters are proposed. Furthermore, a physically consistent dissipation model is employed which is both robust and inexpensive to implement. The cell-centered scheme along with these additional new features are applied to solve solids undergoing elasto-plastic deformation.

  13. Improved Short-Term Outcomes following Orthognathic Surgery Are Associated with High-Volume Centers.

    Science.gov (United States)

    Berlin, Nicholas L; Tuggle, Charles T; Steinbacher, Derek M

    2016-08-01

    Previous studies assessing outcomes following orthognathic surgery rely primarily on single-center/surgeon experience. In addition to issues of generalizability, these studies are limited in evaluating the effect of operative volume on patient outcomes. Orthognathic procedures were identified in the 1999 to 2011 Healthcare Cost and Utilization Project Nationwide Inpatient Sample. Outcomes included occurrence of any in-hospital complication, extended length of stay (>2 days), and increased costs (>$10,784). High-volume hospitals were defined as the 90th percentile of case volume or higher (>31 cases/year). Univariate and multivariate analyses were conducted to identify independent predictors of outcomes. Trend analyses were performed to assess changes in the annual rate of patients treated at high-volume hospitals over the study period. Among 101,692 orthognathic surgery patients, 19.6 percent underwent concurrent ancillary procedures (i.e., genioplasty, rhinoplasty, or septoplasty), and 37.6 percent underwent double-jaw surgery. Fifty-three percent were treated at high-volume hospitals. High-volume hospitals more often performed ancillary procedures (21.4 percent versus 17.4 percent; p surgery (41.3 percent versus 33.4 percent; p orthognathic cases nationwide are performed at a small number of high-volume hospitals. These hospitals discharge patients earlier, perform more complex procedures, and have fewer complications. Risk, III.

  14. Australian Chemistry Test Item Bank: Years 11 & 12. Volume 1.

    Science.gov (United States)

    Commons, C., Ed.; Martin, P., Ed.

    Volume 1 of the Australian Chemistry Test Item Bank, consisting of two volumes, contains nearly 2000 multiple-choice items related to the chemistry taught in Year 11 and Year 12 courses in Australia. Items which were written during 1979 and 1980 were initially published in the "ACER Chemistry Test Item Collection" and in the "ACER…

  15. Incineration as a radioactive waste volume reduction process for CEA nuclear centers

    International Nuclear Information System (INIS)

    Atabek, R.; Chaudon, L.

    1994-01-01

    Incineration processes represent a promising solution for waste volume reduction, and will be increasingly used in the future. The features and performance specifications of low-level waste incinerators with capacities ranging from 10 to 20 kg - h -1 at the Fontenay-aux-Roses, Grenoble and Cadarache nuclear centers in France are briefly reviewed. More extensive knowledge of low-level wastes produced in facilities operated by the Commissariat a l'Energie Atomique (CEA) has allowed us to assess the volume reduction obtained by processing combustible waste in existing incinerators. Research and development work is in progress to improve management procedures for higher-level waste and to build facilities capable of incinerating α - contaminated waste. (authors). 6 refs., 5 figs., 1 tab

  16. Importance of the test volume on the lag phase in biodegradation studies

    DEFF Research Database (Denmark)

    Ingerslev, F.; Torang, Lars; Nyholm, Niels

    2000-01-01

    , degradation failed randomly. Our findings are partly explained by the hypotheses that a sufficient total amount as well as a sufficient concentration of specifically degrading microorganisms or consortia of bacteria must be present initially for biodegradation to get started, from which follows that with too......Increasing the total volume of test medium resulted in decreased lag times (TL) in biodegradability shake flask batch tests conducted with either surface water or with synthetic mineral medium inoculated with supernatant from settled activated sludge. Experiments were performed with test volumes...... small inoculations or with too small test volumes, biodegradation may fail randomly. A straightforward practical implication of the findings is that the test volume in biodegradability tests can significantly influence the lag time and thus sometimes be decisive for the outcome in biodegradation studies....

  17. High Center Volume Does Not Mitigate Risk Associated with Using High Donor Risk Organs in Liver Transplantation.

    Science.gov (United States)

    Beal, Eliza W; Black, Sylvester M; Mumtaz, Khalid; Hayes, Don; El-Hinnawi, Ashraf; Washburn, Kenneth; Tumin, Dmitry

    2017-09-01

    High-risk donor allografts increase access to liver transplant, but potentially reduce patient and graft survival. It is unclear whether the risk associated with using marginal donor livers is mitigated by increasing center experience. The United Network for Organ Sharing registry was queried for adult first-time liver transplant recipients between 2/2002 and 12/2015. High donor risk was defined as donor risk index >1.9, and 1-year patient and graft survival were compared according to donor risk index in small and large centers. Multivariable Cox regression estimated the hazard ratio (HR) associated with using high-risk donor organs, according to a continuous measure of annual center volume. The analysis included 51,770 patients. In 67 small and 67 large centers, high donor risk index predicted increased mortality (p = 0.001). In multivariable analysis, high-donor risk index allografts predicted greater mortality hazard at centers performing 20 liver transplants per year (HR 1.35; 95% CI 1.22, 1.49; p donor risk index and center volume was not statistically significant (p = 0.747), confirming that the risk associated with using marginal donor livers was comparable between smaller and larger centers. Results were consistent when examining graft loss. At both small and large centers, high-risk donor allografts were associated with reduced patient and graft survival after liver transplant. Specific strategies to mitigate the risk of liver transplant involving high-risk donors are needed, in addition to accumulation of center expertise.

  18. The Development of the Acoustic Design of NASA Glenn Research Center's New Reverberant Acoustic Test Facility

    Science.gov (United States)

    Hughes, William O.; McNelis, Mark E.; Hozman, Aron D.; McNelis, Anne M.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is leading the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC s Plum Brook Station in Sandusky, Ohio. Benham Companies, LLC is currently constructing modal, base-shake sine and reverberant acoustic test facilities to support the future testing needs of NASA s space exploration program. The large Reverberant Acoustic Test Facility (RATF) will be approximately 101,000 ft3 in volume and capable of achieving an empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world s known active reverberant acoustic test facilities. The key to achieving the expected acoustic test spectra for a range of many NASA space flight environments in the RATF is the knowledge gained from a series of ground acoustic tests. Data was obtained from several NASA-sponsored test programs, including testing performed at the National Research Council of Canada s acoustic test facility in Ottawa, Ontario, Canada, and at the Redstone Technical Test Center acoustic test facility in Huntsville, Alabama. The majority of these tests were performed to characterize the acoustic performance of the modulators (noise generators) and representative horns that would be required to meet the desired spectra, as well as to evaluate possible supplemental gas jet noise sources. The knowledge obtained in each of these test programs enabled the design of the RATF sound generation system to confidently advance to its final acoustic design and subsequent on-going construction.

  19. Economic viability of geriatric hip fracture centers.

    Science.gov (United States)

    Clement, R Carter; Ahn, Jaimo; Mehta, Samir; Bernstein, Joseph

    2013-12-01

    Management of geriatric hip fractures in a protocol-driven center can improve outcomes and reduce costs. Nonetheless, this approach has not spread as broadly as the effectiveness data would imply. One possible explanation is that operating such a center is not perceived as financially worthwhile. To assess the economic viability of dedicated hip fracture centers, the authors built a financial model to estimate profit as a function of costs, reimbursement, and patient volume in 3 settings: an average US hip fracture program, a highly efficient center, and an academic hospital without a specific hip fracture program. Results were tested with sensitivity analysis. A local market analysis was conducted to assess the feasibility of supporting profitable hip fracture centers. The results demonstrate that hip fracture treatment only becomes profitable when the annual caseload exceeds approximately 72, assuming costs characteristic of a typical US hip fracture program. The threshold of profitability is 49 cases per year for high-efficiency hip fracture centers and 151 for the urban academic hospital under review. The largest determinant of profit is reimbursement, followed by costs and volume. In the authors’ home market, 168 hospitals offer hip fracture care, yet 85% fall below the 72-case threshold. Hip fracture centers can be highly profitable through low costs and, especially, high revenues. However, most hospitals likely lose money by offering hip fracture care due to inadequate volume. Thus, both large and small facilities would benefit financially from the consolidation of hip fracture care at dedicated hip fracture centers. Typical US cities have adequate volume to support several such centers.

  20. Experimental determination of the drywell volume: 1/5 scale pressure suppression test

    International Nuclear Information System (INIS)

    Pitts, J.H.

    1977-01-01

    The BWR Mk 1 1/5 scale drywell volume, including space in all ports up to the first flange, was experimentally determined to be 10.01 m 3 with an uncertainty of +- 0.03 m 3 . The method of measurement used a 0.040879 m 3 calibrated volume that was initially filled with helium to 36.5 MPa. The calibrated volume was then connected to the drywell and the pressures equalized. The volumes of the vent pipes, instrumentation ports, and either the steam inlet or nitrogen inlet were subtracted from the measured drywell volume to obtain the net active drywell volume. The net active drywell volume is 9.87 m 3 for air tests and 9.85 m 3 for steam tests

  1. Estimation of soil properties and free product volume from baildown tests

    International Nuclear Information System (INIS)

    Zhu, J.L.; Parker, J.C.; Lundy, D.A.; Zimmerman, L.M.

    1993-01-01

    Baildown tests, involving measurement of water and free product levels in a monitoring well after bailing, are often performed at spill sites to estimate the oil volume per unit area -- which the authors refer to as ''oil specific volume.'' Spill volume is estimated by integrating oil specific volume over the areal domain of the spill. Existing methods for interpreting baildown tests are based on grossly simplistic approximations of soil capillary properties that cannot accurately describe the transient well response. A model for vertical equilibrium oil distributions based on the van Genuchten capillary model has been documented and verified in the laboratory and in the field by various authors. The model enables oil specific volume and oil transmissivity to be determined as functions of well product thickness. This paper describes a method for estimating van Genuchten capillary parameters, as well as aquifer hydraulic conductivity, from baildown tests. The results yield the relationships of oil specific volume and oil transmissivity to apparent product thickness, which may be used, in turn, to compute spill volume and to model free product plume movement and free product recovery. The method couples a finite element model for radial flow of oil and water to a well with a nonlinear parameter estimation algorithm. Effects of the filter pack around the well in the fluid level response are considered explicitly by the model. The method, which is implemented in the program BAILTEST, is applied to field data from baildown tests. The results indicate that hydrographs of water and oil levels are accurately described by the model

  2. Australian Chemistry Test Item Bank: Years 11 and 12. Volume 2.

    Science.gov (United States)

    Commons, C., Ed.; Martin, P., Ed.

    The second volume of the Australian Chemistry Test Item Bank, consisting of two volumes, contains nearly 2000 multiple-choice items related to the chemistry taught in Year 11 and Year 12 courses in Australia. Items which were written during 1979 and 1980 were initially published in the "ACER Chemistry Test Item Collection" and in the…

  3. Baseline tests for arc melter vitrification of INEL buried wastes. Volume 1: Facility description and summary data report

    International Nuclear Information System (INIS)

    Oden, L.L.; O'Connor, W.K.; Turner, P.C.; Soelberg, N.R.; Anderson, G.L.

    1993-01-01

    This report presents field results and raw data from the Buried Waste Integrated Demonstration (BWID) Arc Melter Vitrification Project Phase 1 baseline test series conducted by the Idaho National Engineering Laboratory (INEL) in cooperation with the U.S. Bureau of Mines (USBM). The baseline test series was conducted using the electric arc melter facility at the USBM Albany Research Center in Albany, Oregon. Five different surrogate waste feed mixtures were tested that simulated thermally-oxidized, buried, TRU-contaminated, mixed wastes and soils present at the INEL. The USBM Arc Furnace Integrated Waste Processing Test Facility includes a continuous feed system, the arc melting furnace, an offgas control system, and utilities. The melter is a sealed, 3-phase alternating current (ac) furnace approximately 2 m high and 1.3 m wide. The furnace has a capacity of 1 metric ton of steel and can process as much as 1,500 lb/h of soil-type waste materials. The surrogate feed materials included five mixtures designed to simulate incinerated TRU-contaminated buried waste materials mixed with INEL soil. Process samples, melter system operations data and offgas composition data were obtained during the baseline tests to evaluate the melter performance and meet test objectives. Samples and data gathered during this program included (a) automatically and manually logged melter systems operations data, (b) process samples of slag, metal and fume solids, and (c) offgas composition, temperature, velocity, flowrate, moisture content, particulate loading and metals content. This report consists of 2 volumes: Volume I summarizes the baseline test operations. It includes an executive summary, system and facility description, review of the surrogate waste mixtures, and a description of the baseline test activities, measurements, and sample collection. Volume II contains the raw test data and sample analyses from samples collected during the baseline tests

  4. Photogrammetry and Laser Imagery Tests for Tank Waste Volume Estimates: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Field, Jim G. [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2013-03-27

    Feasibility tests were conducted using photogrammetry and laser technologies to estimate the volume of waste in a tank. These technologies were compared with video Camera/CAD Modeling System (CCMS) estimates; the current method used for post-retrieval waste volume estimates. This report summarizes test results and presents recommendations for further development and deployment of technologies to provide more accurate and faster waste volume estimates in support of tank retrieval and closure.

  5. Photogrammetry and Laser Imagery Tests for Tank Waste Volume Estimates: Summary Report

    International Nuclear Information System (INIS)

    Field, Jim G.

    2013-01-01

    Feasibility tests were conducted using photogrammetry and laser technologies to estimate the volume of waste in a tank. These technologies were compared with video Camera/CAD Modeling System (CCMS) estimates; the current method used for post-retrieval waste volume estimates. This report summarizes test results and presents recommendations for further development and deployment of technologies to provide more accurate and faster waste volume estimates in support of tank retrieval and closure

  6. A second-order cell-centered Lagrangian ADER-MOOD finite volume scheme on multidimensional unstructured meshes for hydrodynamics

    Science.gov (United States)

    Boscheri, Walter; Dumbser, Michael; Loubère, Raphaël; Maire, Pierre-Henri

    2018-04-01

    In this paper we develop a conservative cell-centered Lagrangian finite volume scheme for the solution of the hydrodynamics equations on unstructured multidimensional grids. The method is derived from the Eucclhyd scheme discussed in [47,43,45]. It is second-order accurate in space and is combined with the a posteriori Multidimensional Optimal Order Detection (MOOD) limiting strategy to ensure robustness and stability at shock waves. Second-order of accuracy in time is achieved via the ADER (Arbitrary high order schemes using DERivatives) approach. A large set of numerical test cases is proposed to assess the ability of the method to achieve effective second order of accuracy on smooth flows, maintaining an essentially non-oscillatory behavior on discontinuous profiles, general robustness ensuring physical admissibility of the numerical solution, and precision where appropriate.

  7. Does Certification as Bariatric Surgery Center and Volume Influence the Outcome in RYGB-Data Analysis of German Bariatric Surgery Registry.

    Science.gov (United States)

    Stroh, Christine; Köckerling, F; Lange, V; Wolff, S; Knoll, C; Bruns, C; Manger, Th

    2017-02-01

    To examine the association between the certification as bariatric surgery center and volume and patient outcome, data collected in the German Bariatric Surgery Registry were evaluated. All data were registered prospectively in cooperation with the Institute of Quality Assurance in Surgery at Otto-von-Guericke University Magdeburg. Data collection began in 2005 for all bariatric procedures in an online database. Participation in the quality assurance study is required for all certified bariatric surgery centers in Germany. Descriptive evaluation and matched pairs analysis were performed. Patients were matched via propensity score taking into account BMI, age, and incidence of comorbidities. During the period from 2005 to 2013, 3083 male and 10,639 female patients were operated on with the RYGB primary approach. In Centers of Competence (77.2 %) and non-accredited hospitals (76.3 %), the proportion of female patients was significantly lower than in Centers of Reference/Excellence (78.7 %; p = 0.002). The mean age in Centers of Reference/Excellence (41.2 years) was significantly lower than in Centers of Competence (43.2 years; p bariatric surgery centers with higher volume. The study supports the concept of certification. There are different factors which can and cannot be preoperatively modified and influence the perioperative outcome.

  8. Design and development of high voltage and high frequency center tapped transformer for HVDC test generator

    International Nuclear Information System (INIS)

    Thaker, Urmil; Saurabh Kumar; Amal, S.; Baruah, U.K.; Bhatt, Animesh

    2015-01-01

    A High Voltage center tapped transformer for high frequency application had been designed, fabricated, and tested. It was designed as a part of 200 kV HVDC Test Generator. The High Frequency operation of transformer increases power density. Therefore it is possible to reduce power supply volume. The step up ratio in High Voltage transformer is limited due to stray capacitance and leakage inductance. The limit was overcome by winding multi secondary outputs. Switching frequency of transformer was 15.8 kHz. Input and output voltages of transformer were 270V and 16.5kV-0V-16.5kV respectively. Power rating of transformer is 7kVA. High Voltage transformer with various winding and core arrangement was fabricated to check variation in electrical characteristics. The transformer used a ferrite core (E Type) and nylon insulated primary and secondary bobbins. Two set of E-E geometry cores had been stacked in order to achieve the estimated core volume. Compared with traditional high voltage transformer, this transformer had good thermal behavior, good line insulation properties and a high power density. In this poster, design procedures, development stages and test results of high voltage and high frequency transformer are presented. Results of various parameters such as transformer loss, temperature rise, insulation properties, impedance of primary and secondary winding, and voltage regulation are discussed. (author)

  9. Job Performance Tests for CH-53E Helicopter Mechanics. Volume 2: Administrative Duties and Job Knowledge Tests

    Science.gov (United States)

    1992-01-01

    SUBTmI.E 5 FU.NDING NUMBERS Job Performance Tests for CII-53E Helicopter Miechanacs - Volume I1: Admiutstrative Duties and Job Knowlede Tests C - N...performance measures to Marine Corps personnel managers . training instructors, and interested researchers who may find them useful. This work comprises...Corps personnel managers , training instructors, and interested researchers who may find them useful. 3. This work comprises two parts: volume I

  10. Acid Pit Stabilization Project (Volume 1 - Cold Testing) and (Volume 2 - Hot Testing)

    International Nuclear Information System (INIS)

    Loomis, G. G.; Zdinak, A. P.; Ewanic, M. A.; Jessmore, J. J.

    1998-01-01

    During the summer and fall of Fiscal Year 1997, a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Treatability Study was performed at the Idaho National Engineering and Environmental Laboratory. The study involved subsurface stabilization of a mixed waste contaminated soil site called the Acid Pit. This study represents the culmination of a successful technology development effort that spanned Fiscal Years 1994-1996. Research and development of the in situ grout stabilization technique was conducted. Hardware and implementation techniques are currently documented in a patent pending with the United States Patent and Trademark Office. The stabilization technique involved using jet grouting of an innovative grouting material to form a monolith out of the contamination zone. The monolith simultaneously provides a barrier to further contaminant migration and closes voids in the soil structure against further subsidence. This is accomplished by chemical incorporation of contaminants into less soluble species and achieving a general reduction in hydraulic conductivity within the monolith. The grout used for this study was TECT-HG, a relatively dense iron oxide-based cementitious grout. The treatability study involved cold testing followed by in situ stabilization of the Acid Pit. Volume 1 of this report discusses cold testing, performed as part of a ''Management Readiness Assessment'' in preparation for going hot. Volume 2 discusses the results of the hot Acid Pit Stabilization phase of this project. Drilling equipment was specifically rigged to reduce the spread of contamination, and all grouting was performed under a concrete block containing void space to absorb any grout returns. Data evaluation included examination of implementability of the grouting process and an evaluation of the contaminant spread during grouting. Following curing of the stabilized pit, cores were obtained and evaluated for toxicity characteristic leach ing

  11. Full-scale borehole sealing test in salt under simulated downhole conditions. Volume 2

    International Nuclear Information System (INIS)

    Scheetz, B.E.; Licastro, P.H.; Roy, D.M.

    1986-05-01

    Large-scale testing of the permeability by brine of a salt/grout sample designed to simulate a borehole plug was conducted. The results of these tests showed that a quantity of fluid equivalent to a permeability of 3 microdarcys was collected during the course of the test. This flow rate was used to estimate the smooth bore aperture. Details of this test ware presented in Volume 1 of this report. This report, Volume 2, covers post-test characterization including a detailed study of the salt/grout interface, as well as determination of the physical/mechanical properties of grout samples molded at Terra Tek, Inc. at the time of the large-scale test. Additional studies include heat of hydration, radial stress, and longitudinal volume changes for an equivalent grout mixture

  12. Plasma Volume Expansion Resulting from Intravenous Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Robert G. Hahn

    2011-01-01

    Full Text Available Objective. To quantify the degree of plasma volume expansion that occurs during an intravenous glucose tolerance test (IVGTT. Methods. Twenty healthy volunteers (mean age, 28 years underwent IVGTTs in which 0.3 g/kg of glucose 30% was injected as a bolus over 1 min. Twelve blood samples were collected over 75 min. The plasma glucose and blood hemoglobin concentrations were used to calculate the volume distribution (Vd and the clearance (CL of both the exogenous glucose and the injected fluid volume. Results. The IVGTT caused a virtually instant plasma volume expansion of 10%. The half-life of the glucose averaged 15 min and the plasma volume expansion 16 min. Correction of the fluid kinetic model for osmotic effects after injection reduced CL for the infused volume by 85%, which illustrates the strength of osmosis in allocating fluid back to the intracellular fluid space. Simulations indicated that plasma volume expansion can be reduced to 60% by increasing the injection time from 1 to 5 min and reducing the glucose load from 0.3 to 0.2 g/kg. Conclusion. A regular IVGTT induced an acute plasma volume expansion that peaked at 10% despite the fact that only 50–80 mL of fluid were administered.

  13. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  14. Center not liable for defamation from false-positive hepatitis test.

    Science.gov (United States)

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  15. PTC test bed upgrades to provide ACSES testing support capabilities at transportation technology center.

    Science.gov (United States)

    2015-06-01

    FRA Task Order 314 upgraded the Positive Train Control (PTC) Test Bed at the Transportation Technology Center to support : testing of PTC systems, components, and related equipment associated with the Advanced Civil Speed Enforcement System : (ACSES)...

  16. Supercompactor force effectiveness as related to dry active waste volume reduction

    International Nuclear Information System (INIS)

    Williams, P.C.; Phillips, W.S.

    1986-01-01

    The first U.S. permanently installed supercompactor is now in operation at the Babcock and Wilcox volume reduction center, Parks Township, Pennsylvania. Tests with various DAW (dry active waste) material have been conducted, recording press force versus drum height as one means of estimating volume reduction capability of this machine at various compaction forces. The results of these tests, as well as other factors, are presented herein

  17. Lessons Learned (3 Years of H2O2 Propulsion System Testing Efforts at NASA's John C. Stennis Space Center)

    Science.gov (United States)

    Taylor, Gary O.

    2001-01-01

    John C. Stennis Space Center continues to support the Propulsion community in an effort to validate High-Test Peroxide as an alternative to existing/future oxidizers. This continued volume of peroxide test/handling activity at Stennis Space Center (SSC) provides numerous opportunities for the SSC team to build upon previously documented 'lessons learned'. SSC shall continue to strive to document their experience and findings as H2O2 issues surface. This paper is intended to capture all significant peroxide issues that we have learned over the last three years. This data (lessons learned) has been formulated from practical handling, usage, storage, operations, and initial development/design of our systems/facility viewpoint. The paper is intended to be an information type tool and limited in technical rational; therefore, presenting the peroxide community with some issues to think about as the continued interest in peroxide evolves and more facilities/hardware are built. These lessons learned are intended to assist industry in mitigating problems and identifying potential pitfalls when dealing with the requirements for handling high-test peroxide.

  18. Practicing the Test Produces Strength Equivalent to Higher Volume Training.

    Science.gov (United States)

    Mattocks, Kevin T; Buckner, Samuel L; Jessee, Matthew B; Dankel, Scott J; Mouser, J Grant; Loenneke, Jeremy P

    2017-09-01

    To determine if muscle growth is important for increasing muscle strength or if changes in strength can be entirely explained from practicing the strength test. Thirty-eight untrained individuals performed knee extension and chest press exercise for 8 wk. Individuals were randomly assigned to either a high-volume training group (HYPER) or a group just performing the one repetition maximum (1RM) strength test (TEST). The HYPER group performed four sets to volitional failure (~8RM-12RM), whereas the TEST group performed up to five attempts to lift as much weight as possible one time each visit. Data are presented as mean (90% confidence interval). The change in muscle size was greater in the HYPER group for both the upper and lower bodies at most but not all sites. The change in 1RM strength for both the upper body (difference of -1.1 [-4.8, 2.4] kg) and lower body (difference of 1.0 [-0.7, 2.8] kg for dominant leg) was not different between groups (similar for nondominant). Changes in isometric and isokinetic torque were not different between groups. The HYPER group observed a greater change in muscular endurance (difference of 2 [1,4] repetitions) only in the dominant leg. There were no differences in the change between groups in upper body endurance. There were between-group differences for exercise volume (mean [95% confidence interval]) of the dominant (difference of 11,049.3 [9254.6-12,844.0] kg) leg (similar for nondominant) and chest press with the HYPER group completing significantly more total volume (difference of 13259.9 [9632.0-16,887.8] kg). These findings suggest that neither exercise volume nor the change in muscle size from training contributed to greater strength gains compared with just practicing the test.

  19. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 66

    International Nuclear Information System (INIS)

    OGAWA, A.

    2005-01-01

    The RIKEN BNL Research Center (RSRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the 'Rikagaku Kenkyusho (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists, A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are sixty nine proceedings volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  20. The Regional Test Center Data Transfer System

    Energy Technology Data Exchange (ETDEWEB)

    Riley, Daniel M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Dept.; Stein, Joshua S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Dept.

    2016-09-01

    The Regional Test Centers are a group of several sites around the US for testing photovoltaic systems and components related to photovoltaic systems. The RTCs are managed by Sandia National Laboratories. The data collected by the RTCs must be transmitted to Sandia for storage, analysis, and reporting. This document describes the methods that transfer the data between remote sites and Sandia as well as data movement within Sandia’s network. The methods described are in force as of September, 2016.

  1. Design and testing of an energy-absorbing crewseat for the F/FB-111 aircraft. Volume 2: Data from seat testing

    Science.gov (United States)

    Shane, S. J.

    1985-01-01

    The unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft is reviewed. A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is presented. An energy absorbing test seat is designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions is conducted at a sled test facility. Comparative tests with operational F-111 crewseats are also conducted. After successful dynamic testing of the seat, more testing is conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests are conducted. The vertical drop tests are used to obtain comparative data between the energy absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series. Volume 2 presents the data obtained during the seat test series, while Volume 3 presents the data from the crew module test series.

  2. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    Science.gov (United States)

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  3. Open-source software for demand forecasting of clinical laboratory test volumes using time-series analysis

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2017-01-01

    Full Text Available Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand.

  4. Testing for lead in toys at day care centers.

    Science.gov (United States)

    Sanders, Martha; Stolz, Julie; Chacon-Baker, Ashley

    2013-01-01

    Exposure to lead-based paint or material has been found to impact children's cognitive and behavioral development at blood lead levels far below current standards. The purpose of the project was to screen for lead in toy items in daycare centers in order to raise awareness of inside environmental lead exposures and minimize lead-based exposures for children. Occupational therapy students in a service learning class tested for lead in ten daycare or public centers using the XRF Thermo Scientific Niton XL3t, a method accepted by the Consumer Product Safety Commission (CPSC). A total of 460 items were tested over a two-month period for an average of 66 toys per setting. Fifty six (56) items tested > 100 ppm, which represented 12% of the entire sample. Items with high lead levels included selected toys constructed with lead-based paint, lead metals, plastics using lead as a color enhancer, and decorative objects. While the actual number of lead-based products is small, the cumulative exposure or habitual use may pose an unnecessary risk to children. Indoor exposures occurred for all day care centers regardless of socio-economic levels. Recommendations to minimize exposures are provided.

  5. New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

    Science.gov (United States)

    Kegley, Jeff; Burdine, Robert V. (Technical Monitor)

    2002-01-01

    A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature Si02 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

  6. Accelerated pavement testing of low-volume paved roads with geocell reinforcement.

    Science.gov (United States)

    2015-03-01

    The Midwest States Accelerated Pavement Testing Pooled-Fund Program, financed by the highway : departments of Kansas, Iowa, Missouri, and New York, has supported an accelerated pavement testing (APT) project : to study the rehabilitation of low-volum...

  7. Characterization of strain rate sensitivity and activation volume using the indentation relaxation test

    International Nuclear Information System (INIS)

    Xu Baoxing; Chen Xi; Yue Zhufeng

    2010-01-01

    We present the possibility of extracting the strain rate sensitivity, activation volume and Helmholtz free energy (for dislocation activation) using just one indentation stress relaxation test, and the approach is demonstrated with polycrystalline copper. The Helmholtz free energy measured from indentation relaxation agrees well with that from the conventional compression relaxation test, which validates the proposed approach. From the indentation relaxation test, the measured indentation strain rate sensitivity exponent is found to be slightly larger, and the indentation activation volume much smaller, than their counterparts from the compression test. The results indicate the involvement of multiple dislocation mechanisms in the indentation test.

  8. Small UAS Test Area at NASA's Dryden Flight Research Center

    Science.gov (United States)

    Bauer, Jeffrey T.

    2008-01-01

    This viewgraph presentation reviews the areas that Dryden Flight Research Center has set up for testing small Unmanned Aerial Systems (UAS). It also reviews the requirements and process to use an area for UAS test.

  9. Breakdown Tests of Composite Materials, and the Importance of the Volume Effect

    DEFF Research Database (Denmark)

    Madsen, Søren Find; Holbøll, Joachim; Henriksen, Mogens

    2005-01-01

    High voltage testing of inhomogeneous composite materials often shows that the stressed volume has a great influence on the result. This paper tries to develop methods of estimating the stressed volume by calculating the theoretical extent of streamer propagation along insulating surfaces...

  10. Maintenance cost control at the Pacific Missile Test Center.

    OpenAIRE

    Jenson, Richard J.

    1980-01-01

    Approved for public release; distribution is unlimited The Pacific Missile Test Center (PMTC) is the Navy's largest Major Range and Test Facility Base, with an investment of over one billion dollars. The majority of this investment is in range test equipment and facilities including radar, telemetry, communication and command/ control systems. Concern is growing over the "excessively obsolete condition of PMTC technical equipment." Improvement of factors concerned with...

  11. Optimizing human semen cryopreservation by reducing test vial volume and repetitive test vial sampling

    DEFF Research Database (Denmark)

    Jensen, Christian F S; Ohl, Dana A; Parker, Walter R

    2015-01-01

    OBJECTIVE: To investigate optimal test vial (TV) volume, utility and reliability of TVs, intermediate temperature exposure (-88°C to -93°C) before cryostorage, cryostorage in nitrogen vapor (VN2) and liquid nitrogen (LN2), and long-term stability of VN2 cryostorage of human semen. DESIGN......: Prospective clinical laboratory study. SETTING: University assisted reproductive technology (ART) laboratory. PATIENT(S): A total of 594 patients undergoing semen analysis and cryopreservation. INTERVENTION(S): Semen analysis, cryopreservation with different intermediate steps and in different volumes (50......-1,000 μL), and long-term storage in LN2 or VN2. MAIN OUTCOME MEASURE(S): Optimal TV volume, prediction of cryosurvival (CS) in ART procedure vials (ARTVs) with pre-freeze semen parameters and TV CS, post-thaw motility after two- or three-step semen cryopreservation and cryostorage in VN2 and LN2. RESULT...

  12. Cranial Tumor Surgical Outcomes at a High-Volume Academic Referral Center.

    Science.gov (United States)

    Brown, Desmond A; Himes, Benjamin T; Major, Brittny T; Mundell, Benjamin F; Kumar, Ravi; Kall, Bruce; Meyer, Fredric B; Link, Michael J; Pollock, Bruce E; Atkinson, John D; Van Gompel, Jamie J; Marsh, W Richard; Lanzino, Giuseppe; Bydon, Mohamad; Parney, Ian F

    2018-01-01

    To determine adverse event rates for adult cranial neuro-oncologic surgeries performed at a high-volume quaternary academic center and assess the impact of resident participation on perioperative complication rates. All adult patients undergoing neurosurgical intervention for an intracranial neoplastic lesion between January 1, 2009, and December 31, 2013, were included. Cases were categorized as biopsy, extra-axial/skull base, intra-axial, or transsphenoidal. Complications were categorized as neurologic, medical, wound, mortality, or none and compared for patients managed by a chief resident vs a consultant neurosurgeon. A total of 6277 neurosurgical procedures for intracranial neoplasms were performed. After excluding radiosurgical procedures and pediatric patients, 4151 adult patients who underwent 4423 procedures were available for analysis. Complications were infrequent, with overall rates of 9.8% (435 of 4423 procedures), 1.7% (73 of 4423), and 1.4% (63 of 4423) for neurologic, medical, and wound complications, respectively. The rate of perioperative mortality was 0.3% (14 of 4423 procedures). Case performance and management by a chief resident did not negatively impact outcome. In our large-volume brain tumor practice, rates of complications were low, and management of cases by chief residents in a semiautonomous manner did not negatively impact surgical outcomes. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  13. Reducing test-data volume and test-power simultaneously in LFSR reseeding-based compression environment

    Energy Technology Data Exchange (ETDEWEB)

    Wang Weizheng; Kuang Jishun; You Zhiqiang; Liu Peng, E-mail: jshkuang@163.com [College of Information Science and Engineering, Hunan University, Changsha 410082 (China)

    2011-07-15

    This paper presents a new test scheme based on scan block encoding in a linear feedback shift register (LFSR) reseeding-based compression environment. Meanwhile, our paper also introduces a novel algorithm of scan-block clustering. The main contribution of this paper is a flexible test-application framework that achieves significant reductions in switching activity during scan shift and the number of specified bits that need to be generated via LFSR reseeding. Thus, it can significantly reduce the test power and test data volume. Experimental results using Mintest test set on the larger ISCAS'89 benchmarks show that the proposed method reduces the switching activity significantly by 72%-94% and provides a best possible test compression of 74%-94% with little hardware overhead. (semiconductor integrated circuits)

  14. Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W

    2017-01-01

    Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2  = 0.839; p volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  15. Safety and Environment- Masterplan 2020 of DLR's Rocket Test Center Lampoldhausen

    Science.gov (United States)

    Haberzettl, Andreas; Dommers, Michael

    2013-09-01

    The German Aerospace Center DLR is the German research institute with approximately 7000 employees in 16 domestic locations. Among the research priorities of the German Aerospace Center DLR includes aerospace, energy and transport. DLR is institutionally supported by federal and state governments.Next funding sources arise in the context of third-party funds business (contract research and public contracts and subsidiaries). Main activities of the test center Lampoldshausen are testing of ARIANE's main and upper stage engines in the frame of ESA contracts.In the last years the test center of the DLR in Lampoldshausen has grown strongly, so that the number of employees is actually of about 230. The testing department is mainly responsible for rocket combustion testing according to customer requirements.Two kinds of test facilities are operated, sea level test benches and the altitude simulation test facilities.In addition to the DLR's growth also the activities of the industrial partner ASTRIUM has been elevated so that actually nearly 600 employees are present on site Lampoldshausen.The management of the site in relation to safety and security requires special measures with special respect to the presence of more people inside the testing area in order to guarantee trouble-free and safe experimental operation onsite the DLR's test plants. In order to meet with the future needs of continuing growth, the security and safety requirements have to be adopted.This report gives comprehensive outlook information about future possible scenarios of our coming tasks.Main driving force for future requests is the evolution of the rocket ARIANE. The testing of the new upper stage test facility for ARIANE 5 midlife evolution has been started. A new test position P5.2 is foreseen to perform the qualification of the new upper stage with the VINCI engine. This project will be very complex, in parallel running operation processes will require special procedures related to the overall

  16. Probing Aircraft Flight Test Hazard Mitigation for the Alternative Fuel Effects on Contrails and Cruise Emissions (ACCESS) Research Team . Volume 2; Appendices

    Science.gov (United States)

    Kelly, Michael J.

    2013-01-01

    The Alternative Fuel Effects on Contrails and Cruise Emissions (ACCESS) Project Integration Manager requested in July 2012 that the NASA Engineering and Safety Center (NESC) form a team to independently assess aircraft structural failure hazards associated with the ACCESS experiment and to identify potential flight test hazard mitigations to ensure flight safety. The ACCESS Project Integration Manager subsequently requested that the assessment scope be focused predominantly on structural failure risks to the aircraft empennage (horizontal and vertical tail). This report contains the Appendices to Volume I.

  17. Tamper-indicating devices and safeguards seals evaluation test report. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Horton, P.R.V.; Waddoups, I.G.

    1995-08-01

    Volume I was based on a survey and an evaluation of seals that are used as tamper-indicating devices at DOE facilities. For that evaluation, currently available seals were physically and environmentally evaluated under two broad categories: handling durability and tamper resistance. Our study indicated that the environmental testing had no negative effects on the results of the mechanical tests. In Volume II, we evaluate some loop, fiber optic loop, and pressure-sensitive seals that are not used at DOE facilities. However, we continue to focus on qualities required by DOE: durability and tamper resistance. The seals are comparatively rated, and recommendations are made for using currently available seals and new tamper-indicating device technology.

  18. Tamper-indicating devices and safeguards seals evaluation test report. Volume 2

    International Nuclear Information System (INIS)

    Horton, P.R.V.; Waddoups, I.G.

    1995-08-01

    Volume I was based on a survey and an evaluation of seals that are used as tamper-indicating devices at DOE facilities. For that evaluation, currently available seals were physically and environmentally evaluated under two broad categories: handling durability and tamper resistance. Our study indicated that the environmental testing had no negative effects on the results of the mechanical tests. In Volume II, we evaluate some loop, fiber optic loop, and pressure-sensitive seals that are not used at DOE facilities. However, we continue to focus on qualities required by DOE: durability and tamper resistance. The seals are comparatively rated, and recommendations are made for using currently available seals and new tamper-indicating device technology

  19. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. It is presented in two volumes. This second volume provides more detailed information regarding the methods discussed in Volume 1.

  20. A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xiongbiao, E-mail: xiongbiao.luo@gmail.com [Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada)

    2014-06-15

    Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An

  1. A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

    International Nuclear Information System (INIS)

    Luo, Xiongbiao

    2014-01-01

    Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min −1 . The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An

  2. Solar-energy heats a transportation test center--Pueblo, Colorado

    Science.gov (United States)

    1981-01-01

    Petroleum-base, thermal energy transport fluid circulating through 583 square feet of flat-plate solar collectors accumulates majority of energy for space heating and domestic hot-water of large Test Center. Report describes operation, maintenance, and performance of system which is suitable for warehouses and similar buildings. For test period from February 1979 to January 1980, solar-heating fraction was 31 percent, solar hot-water fraction 79 percent.

  3. Test and Approval Center for Fuel Cell and Hydrogen Technologies: Phase I. Initiation

    DEFF Research Database (Denmark)

    already spent on these technologies also lead to commercial success. The project ‘Test and Approval Center for Fuel Cell and Hydrogen Technologies: Phase I. Initiation’ was aiming at starting with the Establishment of such a center. The following report documents the achievements within the project...... of the fluctuating wind energy. As the fuel cell and hydrogen technologies come closer to commercialization, development of testing methodology, qualified testing and demonstration become increasingly important. Danish industrial players have expressed a strong need for support in the process to push fuel cell...... and hydrogen technologies from the research and development stage into the commercial domain. A Center to support industry with test, development, analysis, approval, certification, consultation, and training in the areas of fuel cell and hydrogen technologies was needed. Denmark has demonstrated leading...

  4. Analysis of a Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Wu, Hsi-Yung T.; Shaw, Peter; Przekop, Adam

    2013-01-01

    The hybrid wing body center section test article is an all-composite structure made of crown, floor, keel, bulkhead, and rib panels utilizing the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) design concept. The primary goal of this test article is to prove that PRSEUS components are capable of carrying combined loads that are representative of a hybrid wing body pressure cabin design regime. This paper summarizes the analytical approach, analysis results, and failure predictions of the test article. A global finite element model of composite panels, metallic fittings, mechanical fasteners, and the Combined Loads Test System (COLTS) test fixture was used to conduct linear structural strength and stability analyses to validate the specimen under the most critical combination of bending and pressure loading conditions found in the hybrid wing body pressure cabin. Local detail analyses were also performed at locations with high stress concentrations, at Tee-cap noodle interfaces with surrounding laminates, and at fastener locations with high bearing/bypass loads. Failure predictions for different composite and metallic failure modes were made, and nonlinear analyses were also performed to study the structural response of the test article under combined bending and pressure loading. This large-scale specimen test will be conducted at the COLTS facility at the NASA Langley Research Center.

  5. Bibliography, subject index, and author index of the literature examined by the Radiation Shielding Information Center. Volume 7

    Energy Technology Data Exchange (ETDEWEB)

    Trubey, D.K.; Roussin, R.W.; Gustin, A.B.

    1983-08-01

    An indexed bibliography of open literature selected by the Radiation Shielding Information Center since the previous volume was published in 1980 is presented in the area of radiation transport and shielding against radiation from nuclear reactors (fission and fusion), x-ray machines, radioisotopes, nuclear weapons (including fallout, and low energy accelerators (e.g., neutron generators). The bibliography was typeset from computer files constituting the RSIC Storage and Retrieval Information System. In addition to lists of literature titles by subject categories (accessions 6201-10156), an author index is given. Most of the literature selected for Volume VII was published in the years 1977 to 1981.

  6. Bibliography, subject index, and author index of the literature examined by the Radiation Shielding Information Center. Volume 7

    International Nuclear Information System (INIS)

    Trubey, D.K.; Roussin, R.W.; Gustin, A.B.

    1983-08-01

    An indexed bibliography of open literature selected by the Radiation Shielding Information Center since the previous volume was published in 1980 is presented in the area of radiation transport and shielding against radiation from nuclear reactors (fission and fusion), x-ray machines, radioisotopes, nuclear weapons (including fallout, and low energy accelerators (e.g., neutron generators). The bibliography was typeset from computer files constituting the RSIC Storage and Retrieval Information System. In addition to lists of literature titles by subject categories (accessions 6201-10156), an author index is given. Most of the literature selected for Volume VII was published in the years 1977 to 1981

  7. Lewis Research Center space station electric power system test facilities

    Science.gov (United States)

    Birchenough, Arthur G.; Martin, Donald F.

    1988-01-01

    NASA Lewis Research Center facilities were developed to support testing of the Space Station Electric Power System. The capabilities and plans for these facilities are described. The three facilities which are required in the Phase C/D testing, the Power Systems Facility, the Space Power Facility, and the EPS Simulation Lab, are described in detail. The responsibilities of NASA Lewis and outside groups in conducting tests are also discussed.

  8. The 2012 Brown Center Report on American Education: How Well Are American Students Learning? With Sections on Predicting the Effect of the Common Core State Standards, Achievement Gaps on the Two NAEP Tests, and Misinterpreting International Test Scores. Volume III, Number 1

    Science.gov (United States)

    Loveless, Tom

    2012-01-01

    This edition of the Brown Center Report on American Education marks the first issue of volume three--and eleventh issue over all. The first installment was published in 2000, just as the Presidential campaigns of George W. Bush and Al Gore were winding down. Education was an important issue in that campaign. It has not been thus far in the current…

  9. Human-centered automation of testing, surveillance and maintenance

    International Nuclear Information System (INIS)

    Bhatt, S.C.; Sun, B.K.H.

    1991-01-01

    Manual surveillance and testing of instrumentation, control and protection systems at nuclear power plants involves system and human errors which can lead to substantial plant down time. Frequent manual testing can also contribute significantly to operation and maintenance cost. Automation technology offers potential for prudent applications at the power plant to reduce testing errors and cost. To help address the testing problems and to harness the benefit of automation application, input from utilities is obtained on suitable automation approaches. This paper includes lessens from successful past experience at a few plants where some island of automation exist. The results are summarized as a set of specifications for semi automatic testing. A human-centered automation methodology is proposed with the guidelines for optimal human/computer division of tasks given. Implementation obstacles for significant changes of testing practices are identified and methods acceptable to nuclear power plants for addressing these obstacles have been suggested

  10. Development and Testing of the Glenn Research Center Visitor's Center Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2009-01-01

    The NASA Glenn Research Center (GRC) has developed, installed, and tested a 12 kW DC grid-tied photovoltaic (PV) power system at the GRC Visitor s Center. This system utilizes a unique ballast type roof mount for installing the photovoltaic panels on the roof of the Visitor s Center with no alterations or penetrations to the roof. The PV system has generated in excess of 15000 kWh since operation commenced in August 2008. The PV system is providing power to the GRC grid for use by all. Operation of the GRC Visitor s Center PV system has been completely trouble free. A grid-tied PV power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provides valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. Based upon the success of the GRC Visitor s Center PV system, additional PV power system expansion at GRC is under consideration. The GRC Visitor s Center grid-tied PV power system was successfully designed and developed which served to validate the basic principles

  11. Science Library of Test Items. Volume Eight. Mastery Testing Program. Series 3 & 4 Supplements to Introduction and Manual.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    Continuing a series of short tests aimed at measuring student mastery of specific skills in the natural sciences, this supplementary volume includes teachers' notes, a users' guide and inspection copies of test items 27 to 50. Answer keys and test scoring statistics are provided. The items are designed for grades 7 through 10, and a list of the…

  12. Challenges and solutions for high-volume testing of silicon photonics

    Science.gov (United States)

    Polster, Robert; Dai, Liang Yuan; Oikonomou, Michail; Cheng, Qixiang; Rumley, Sebastien; Bergman, Keren

    2018-02-01

    The first generation of silicon photonic products is now commercially available. While silicon photonics possesses key economic advantages over classical photonic platforms, it has yet to become a commercial success because these advantages can be fully realized only when high-volume testing of silicon photonic devices is made possible. We discuss the costs, challenges, and solutions of photonic chip testing as reported in the recent research literature. We define and propose three underlying paradigms that should be considered when creating photonic test structures: Design for Fast Coupling, Design for Minimal Taps, and Design for Parallel Testing. We underline that a coherent test methodology must be established prior to the design of test structures, and demonstrate how an optimized methodology dramatically reduces the burden when designing for test, by reducing the needed complexity of test structures.

  13. Kodak Mirror Assembly Tested at Marshall Space Flight Center

    Science.gov (United States)

    2003-01-01

    This photo (a frontal view) is of one of many segments of the Eastman-Kodak mirror assembly being tested for the James Webb Space Telescope (JWST) project at the X-Ray Calibration Facility at Marshall Space Flight Center (MSFC). MSFC is supporting Goddard Space Flight Center (GSFC) in developing the JWST by taking numerous measurements to predict its future performance. The tests are conducted in a vacuum chamber cooled to approximate the super cold temperatures found in space. During its 27 years of operation, the facility has performed testing in support of a wide array of projects, including the Hubble Space Telescope (HST), Solar A, Chandra technology development, Chandra High Resolution Mirror Assembly and science instruments, Constellation X-Ray Mission, and Solar X-Ray Imager, currently operating on a Geostationary Operational Environment Satellite. The JWST is NASA's next generation space telescope, a successor to the Hubble Space Telescope, named in honor of NASA's second administrator, James E. Webb. It is scheduled for launch in 2010 aboard an expendable launch vehicle. It will take about 3 months for the spacecraft to reach its destination, an orbit of 940,000 miles in space.

  14. Computer-aided dispatch--traffic management center field operational test final detailed test plan : WSDOT deployment

    Science.gov (United States)

    2003-10-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...

  15. Regional Test Center Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Burnham, Laurie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jones, Christian Birk [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    The U.S. DOE Regional Test Center for Solar Technologies program was established to validate photovoltaic (PV) technologies installed in a range of different climates. The program is funded by the Energy Department's SunShot Initiative. The initiative seeks to make solar energy cost competitive with other forms of electricity by the end of the decade. Sandia National Laboratory currently manages four different sites across the country. The National Renewable Energy Laboratory manages a fifth site in Colorado. The entire PV portfolio currently includes 20 industry partners and almost 500 kW of installed systems. The program follows a defined process that outlines tasks, milestones, agreements, and deliverables. The process is broken out into four main parts: 1) planning and design, 2) installation, 3) operations, and 4) decommissioning. This operations manual defines the various elements of each part.

  16. Computer-aided dispatch--traffic management center field operational test final test plans : state of Utah

    Science.gov (United States)

    2004-01-01

    The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...

  17. The effect of alternative work schedules (AWS) on performance during acquisition based testing at the U.S. Army Aberdeen Test Center

    OpenAIRE

    Thomas, Alicia J.

    2014-01-01

    Approved for public release; distribution is unlimited This project analyzed the effects of an alternate work schedule (AWS) on the performance of acquisition based testing conducted at the U.S. Army Aberdeen Test Center (ATC), a subordinate test center to the U.S. Army Test and Evaluation Command. The literature review uncovered how an AWS improved employee work and life balance and performance at three separate external companies. Other potential AWS success factors such as employee abse...

  18. The design, development, and test of balloonborne and groundbased lidar systems. Volume 2: Flight test of Atmospheric Balloon Lidar Experiment, ABLE 2

    Science.gov (United States)

    Shepherd, O.; Bucknam, R. D.; Hurd, A. G.; Sheehan, W. H.

    1991-06-01

    This is Volume 3 of a three volume final report on the design, development, and test of balloonborne and groundbased lidar systems. Volume 1 describes the design and fabrication of a balloonborne CO2 coherent payload to measure the 10.6 micrometers backscatter from atmospheric aerosols as a function of altitude. Volume 2 describes the Aug. 1987 flight test of Atmospheric Balloonborne Lidar Experiment, ABLE 2. In this volume we describe groundbased lidar development and measurements. A design was developed for installation of the ABLE lidar in the GL rooftop dome. A transportable shed was designed to house the ABLE lidar at the various remote measurement sites. Refurbishment and modification of the ABLE lidar were completed to permit groundbased lidar measurements of clouds and aerosols. Lidar field measurements were made at Ascension Island during SABLE 89. Lidar field measurements were made at Terciera, Azores during GABLE 90. These tasks were successfully completed, and recommendations for further lidar measurements and data analysis were made.

  19. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  20. Weibull statistics effective area and volume in the ball-on-ring testing method

    DEFF Research Database (Denmark)

    Frandsen, Henrik Lund

    2014-01-01

    The ball-on-ring method is together with other biaxial bending methods often used for measuring the strength of plates of brittle materials, because machining defects are remote from the high stresses causing the failure of the specimens. In order to scale the measured Weibull strength...... to geometries relevant for the application of the material, the effective area or volume for the test specimen must be evaluated. In this work analytical expressions for the effective area and volume of the ball-on-ring test specimen is derived. In the derivation the multiaxial stress field has been accounted...

  1. Shake-table testing of a self-centering precast reinforced concrete frame with shear walls

    Science.gov (United States)

    Lu, Xilin; Yang, Boya; Zhao, Bin

    2018-04-01

    The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination of unbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.

  2. BWR spent fuel storage cask performance test. Volume 2. Pre- and post-test decay heat, heat transfer, and shielding analyses

    International Nuclear Information System (INIS)

    Wiles, L.E.; Lombardo, N.J.; Heeb, C.M.; Jenquin, U.P.; Michener, T.E.; Wheeler, C.L.; Creer, J.M.; McCann, R.A.

    1986-06-01

    This report describes the decay heat, heat transfer, and shielding analyses conducted in support of performance testing of a Ridhihalgh, Eggers and Associates REA 2033 boiling water reactor (BWR) spent fuel storage cask. The cask testing program was conducted for the US Department of Energy (DOE) Commercial Spent Fuel Management Program by the Pacific Northwest Laboratory (PNL) and by General Electric at the latters' Morris Operation (GE-MO) as reported in Volume I. The analyses effort consisted of performing pretest calculations to (1) select spent fuel for the test; (2) symmetrically load the spent fuel assemblies in the cask to ensure lateral symmetry of decay heat generation rates; (3) optimally locate temperature and dose rate instrumentation in the cask and spent fuel assemblies; and (4) evaluate the ORIGEN2 (decay heat), HYDRA and COBRA-SFS (heat transfer), and QAD and DOT (shielding) computer codes. The emphasis of this second volume is on the comparison of code predictions to experimental test data in support of the code evaluation process. Code evaluations were accomplished by comparing pretest (actually pre-look, since some predictions were not completed until testing was in progress) predictions with experimental cask testing data reported in Volume I. No attempt was made in this study to compare the two heat transfer codes because results of other evaluations have not been completed, and a comparison based on one data set may lead to erroneous conclusions

  3. Environmental control and life support testing at the Marshall Space Flight Center

    Science.gov (United States)

    Schunk, Richard G.; Humphries, William R.

    1987-01-01

    The Space Station Environmental Control and Life Support System (ECLSS) test program at the Marshall Space Flight Center (MSFC) is addressed. The immediate goals and current activities of the test program are discussed. Also described are the Core Module Integration Facility (CMIF) and the initial ECLSS test configuration. Future plans for the ECLSS test program and the CMIF are summarized.

  4. Center of buoyancy definition

    International Nuclear Information System (INIS)

    Sandberg, V.

    1988-12-01

    The center of buoyancy of an arbitrary shaped body is defined in analogy to the center of gravity. The definitions of the buoyant force and center of buoyancy in terms of integrals over the area of the body are converted to volume integrals and shown to have simple intuitive interpretations

  5. Is the adjustable transobturator system ATOMS® useful for the treatment of male urinary incontinence in low to medium volume urological centers?

    Science.gov (United States)

    Manso, M; Alexandre, B; Antunes-Lopes, T; Martins-da-Silva, C; Cruz, F

    2018-05-01

    Urinary incontinence (UI) is a complication of radical prostatectomy (RP) and transurethral resection of the prostate (TURP). The gold-standard treatment is the artificial urinary sphincter, however, new treatments have been investigated. To examine the outcome of an adjustable transobturator male system (ATOMS ® ) in men with UI after prostatic surgery in a low to medium volume continence center. Twenty-five men with UI were implanted with ATOMS ® system between 2012 and 2014. The most common indication was UI after RP (92%), followed by UI after TURP (8%). Eleven patients (44%) had received adjuvant external beam radiotherapy (RT). Patients were considered to be 'dry' if they stopped wearing pads or needed just one protective pad per day; and improved if the daily number of pads used decreased by at least half. The Incontinence Quality of Life questionnaire (ICIQ-SF) was used, adding a verbal question about the satisfaction of the patient considering the outcome. After a mean follow-up of 21.56 months, 64% were dry and 8% revealed a significant improvement. The success of the procedure was negatively correlated with the severity of the previous UI and with previous treatment with RT. Concerning patients satisfaction, 84% of the patients would repeat the procedure. ATOMS ® offers good rates of cure and improvement of UI after prostatic surgery with a reasonable rate of minor complications. The results of this study, performed in a low to medium volume continence center, are comparable to the results achieved in high volume continence centers. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Test bed control center design concept for Tank Waste Retrieval Manipulator Systems

    International Nuclear Information System (INIS)

    Sundstrom, E.; Draper, J.V.; Fausz, A.

    1995-01-01

    This paper describes the design concept for the control center for the Single Shell Tank Waste Retrieval Manipulator System test bed and the design process behind the concept. The design concept supports all phases of the test bed mission, including technology demonstration, comprehensive system testing, and comparative evaluation for further development and refinement of the TWRMS for field operations

  7. Nonlinear Analysis and Preliminary Testing Results of a Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.; Wu, Hsi-Yung T.

    2015-01-01

    A large test article was recently designed, analyzed, fabricated, and successfully tested up to the representative design ultimate loads to demonstrate that stiffened composite panels with through-the-thickness reinforcement are a viable option for the next generation large transport category aircraft, including non-conventional configurations such as the hybrid wing body. This paper focuses on finite element analysis and test data correlation of the hybrid wing body center section test article under mechanical, pressure and combined load conditions. Good agreement between predictive nonlinear finite element analysis and test data is found. Results indicate that a geometrically nonlinear analysis is needed to accurately capture the behavior of the non-circular pressurized and highly-stressed structure when the design approach permits local buckling.

  8. Cross-correlations in volume space: Differences between buy and sell volumes

    Science.gov (United States)

    Lee, Sun Young; Hwang, Dong Il; Kim, Min Jae; Koh, In Gyu; Kim, Soo Yong

    2011-03-01

    We study the cross-correlations of buy and sell volumes on the Korean stock market in high frequency. We observe that the pulling effects of volumes are as small as that of returns. The properties of the correlations of buy and sell volumes differ. They are explained by the degree of synchronization of stock volumes. Further, the pulling effects on the minimal spanning tree are studied. In minimal spanning trees with directed links, the large pulling effects are clustered at the center, not uniformly distributed. The Epps effect of buy and sell volumes are observed. The reversal of the cross-correlations of buy and sell volumes is also detected.

  9. Pediatric blood volumes: a one-page reference guide.

    Science.gov (United States)

    Smiley, J; Reitan, J

    1998-10-01

    At our institution, a multidisciplinary team met to work out a blood volume policy for our pediatric patients' laboratory testing. Because we are a cancer center, many of our patients are on protocols and/or are in the hospital for an extended period of time. These factors result in multiple blood draws. It is important to manage the volumes used so that we do not compromise the hematological status of our pediatric patients. The concerns of nurses and laboratory technologists were discussed and a three-tiered system was designed consisting of adult volumes, volumes for inflexibility to verify or add to the original order without resticking the patient increase at each tier. It is imperative to the overall quality of care for all patients that discretion is used when following these guidelines. When it is medically prudent to restrict the blood volumes taken from any patient, it should be done. However, when it is not medically necessary, the increased costs and potential decrease in the quality of laboratory service outweighs the desire to use smaller blood volumes.

  10. The design, development, and test of balloonborne and groundbased lidar systems. Volume 3: Groundbased lidar systems

    Science.gov (United States)

    Shepherd, O.; Aurilio, G.; Bucknam, R. D.; Hurd, A. G.; Robertie, N. F.

    1991-06-01

    This is Volume 3 of a three volume final report on the design, development and test of balloonborne and groundbased lidar systems. Volume 1 describes the design and fabrication of a balloonborne CO2 coherent payload to measure the 10.6 micrometers backscatter from atmospheric aerosols as a function of altitude. Volume 2 describes the August 1987 flight test of Atmospheric Balloonborne Lidar Experiment, ABLE 2. In this volume we describe groundbased lidar development and measurements. A design was developed for installation of the ABLE lidar in the GL rooftop dome. A transportable shed was designed to house the ABLE lidar at the various remote measurement sites. Refurbishment and modification of the ABLE lidar were completed to permit groundbased lidar measurements of clouds and aerosols. Lidar field measurements were made at Ascension Island during SABLE 89. Lidar field measurements were made at Terciera, Azores during GABLE 90. These tasks have been successfully completed, and recommendations for further lidar measurements and data analysis have been made.

  11. Optimisation of Forensic Genetics Procedures Used in Disputed Paternity Testing: Adjustment of the PCR Reaction Volume

    Directory of Open Access Journals (Sweden)

    Damir Marjanović

    2006-05-01

    Full Text Available Standard molecular techniques, with only a slight modification, are very useful in obtaining and interpreting the final results in the field of forensic genetic. Data obtained through such analysis are highly reliable and can be used as a very powerful tool that produces valuable results. However, success and swiftness of DNA typing of biological evidence either that found at a crime scene or used in disputed paternity testing, depends on the optimization of numerous factors. One of the most important and critical phases that ensures reliability of the whole procedure is the choice of the most suitable volume for the amplification protocol. Buccal swabs were collected from volunteers. DNA was extracted by Qiagen Dnaeasy Tissue Kit. PowerPlex 16 kit was used to simultaneously amplify 15 STR loci by PCR. Amplification was carried out as described previously. The tested total working reaction volumes were 5, 10 and 25 microl. The PCR amplification was carried out in PE Gene Amp PCR System Thermal Cycler (ABI, Foster City, CA. Amplification products were analyzed on an ABI PRISM 377 instrument (ABI, Foster City, CA in 5% bis-acrilamide gel. Amplification was generally successful for all the tested reaction volumes. Lower partial to complete DNA profiles ratio, the quality of obtained STR profiles, significantly reduced amount of reaction's components give advantage to 5 microl reaction volume over other two tested volumes in this case.

  12. Specialization and utilization after hepatectomy in academic medical centers.

    Science.gov (United States)

    Shaw, Joshua J; Santry, Heena P; Shah, Shimul A

    2013-11-01

    Specialized procedures such as hepatectomy are performed by a variety of specialties in surgery. We aimed to determine whether variation exists among utilization of resources, cost, and patient outcomes by specialty, surgeon case volume, and center case volume for hepatectomy. We queried centers (n = 50) in the University Health Consortium database from 2007-2010 for patients who underwent elective hepatectomy in which specialty was designated general surgeon (n = 2685; 30%) or specialist surgeon (n = 6277; 70%), surgeon volume was designated high volume (>38 cases annually) and center volume was designated high volume (>100 cases annually). We then stratified our cohort by primary diagnosis, defined as primary tumor (n = 2241; 25%), secondary tumor (n = 5466; 61%), and benign (n = 1255; 14%). Specialist surgeons performed more cases for primary malignancy (primary 26% versus 15%) while general surgeons operated more for secondary malignancies (67% versus 61%) and benign disease (18% versus 13%). Specialists were associated with a shorter total length of stay (LOS) (5 d versus 6 d; P specialization, surgeon volume and center volume may be important metrics for quality and utilization in complex procedures like hepatectomy. Further studies are necessary to link direct factors related to hospital performance in the changing healthcare environment. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. The Center-TRACON Automation System: Simulation and field testing

    Science.gov (United States)

    Denery, Dallas G.; Erzberger, Heinz

    1995-01-01

    A new concept for air traffic management in the terminal area, implemented as the Center-TRACON Automation System, has been under development at NASA Ames in a cooperative program with the FAA since 1991. The development has been strongly influenced by concurrent simulation and field site evaluations. The role of simulation and field activities in the development process will be discussed. Results of recent simulation and field tests will be presented.

  14. Associations of hypoosmotic swelling test, relative sperm volume shift, aquaporin7 mRNA abundance and bull fertility estimates.

    Science.gov (United States)

    Kasimanickam, R K; Kasimanickam, V R; Arangasamy, A; Kastelic, J P

    2017-02-01

    Mammalian sperm are exposed to a natural hypoosmotic environment during male-to-female reproductive tract transition; although this activates sperm motility in vivo, excessive swelling can harm sperm structure and function. Aquaporins (AQPs) is a family of membrane-channel proteins implicated in sperm osmoregulation. The objective was to determine associations among relative sperm volume shift, hypoosmotic swelling test (HOST), sperm aquaporin (AQP) 7 mRNA abundances, and sire conception rate (SCR; fertility estimate) in Holstein bulls at a commercial artificial insemination center. Three or four sires for each full point SCR score from -4 to +4 were included. Each SCR estimate for study bulls (N = 30) was based on > 500 services (mean ± SEM) of 725 ± 13 services/sire). Sperm from a single collection day (two ejaculates) from these commercial Holstein bulls were used. Relative mRNA expression of AQP7 in sperm was determined by polymerase chain reaction. Mean relative sperm volume shift and percentage of sperm reacted in a HOST (% HOST) were determined (400 sperm per bull) after incubating in isoosmotic (300 mOsm/kg) and hypoosmotic (100 mOsm/kg) solutions for 30 min. There was no correlation between %HOST and SCR (r = 0.28 P > 0.1). However, there was a positive correlation between relative sperm volume shift and SCR (r = 0.65, P 2) fertility sire groups. In conclusion, bulls with higher SCR had significantly greater AQP7 mRNA abundance in frozen-thawed sperm. This plausibly contributed to greater regulation of sperm volume shift, which apparently conferred protection from detrimental swelling and impaired functions. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Heater test planning for the Near Surface Test Facility at the Hanford reservation. Volume II. Appendix

    International Nuclear Information System (INIS)

    DuBois, A.; Binnall, E.; Chan, T.; McEvoy, M.; Nelson, P.; Remer, J.

    1979-04-01

    Volume II contains the following information: theoretical support for radioactive waste storage projects - development of data analysis methods and numerical models; injectivity temperature profiling as a means of permeability characterization; geophysical holes at the Near Surface Test Facility (NSTF), Hanford; proposed geophysical and hydrological measurements at NSTF; suggestions for characterization of the discontinuity system at NSTF; monitoring rock property changes caused by radioactive waste storage using the electrical resistivity method; microseismic detection system for heated rock; Pasco Basin groundwater contamination study; a letter to Mark Board on Gable Mountain Faulting; report on hydrofracturing tests for in-situ stress measurement, NSTF, Hole DC-11, Hanford Reservation; and borehole instrumentation layout for Hanford Near Surface Test Facility

  16. Standardization of waste acceptance test methods by the Materials Characterization Center

    International Nuclear Information System (INIS)

    Slate, S.C.

    1985-01-01

    This paper describes the role of standardized test methods in demonstrating the acceptability of high-level waste (HLW) forms for disposal. Key waste acceptance tests are standardized by the Materials Characterization Center (MCC), which the US Department of Energy (DOE) has established as the central agency in the United States for the standardization of test methods for nuclear waste materials. This paper describes the basic three-step process that is used to show that waste is acceptable for disposal and discusses how standardized tests are used in this process. Several of the key test methods and their areas of application are described. Finally, future plans are discussed for using standardized tests to show waste acceptance. 9 refs., 1 tab

  17. Broadband Fan Noise Prediction System for Turbofan Engines. Volume 3; Validation and Test Cases

    Science.gov (United States)

    Morin, Bruce L.

    2010-01-01

    Pratt & Whitney has developed a Broadband Fan Noise Prediction System (BFaNS) for turbofan engines. This system computes the noise generated by turbulence impinging on the leading edges of the fan and fan exit guide vane, and noise generated by boundary-layer turbulence passing over the fan trailing edge. BFaNS has been validated on three fan rigs that were tested during the NASA Advanced Subsonic Technology Program (AST). The predicted noise spectra agreed well with measured data. The predicted effects of fan speed, vane count, and vane sweep also agreed well with measurements. The noise prediction system consists of two computer programs: Setup_BFaNS and BFaNS. Setup_BFaNS converts user-specified geometry and flow-field information into a BFaNS input file. From this input file, BFaNS computes the inlet and aft broadband sound power spectra generated by the fan and FEGV. The output file from BFaNS contains the inlet, aft and total sound power spectra from each noise source. This report is the third volume of a three-volume set documenting the Broadband Fan Noise Prediction System: Volume 1: Setup_BFaNS User s Manual and Developer s Guide; Volume 2: BFaNS User s Manual and Developer s Guide; and Volume 3: Validation and Test Cases. The present volume begins with an overview of the Broadband Fan Noise Prediction System, followed by validation studies that were done on three fan rigs. It concludes with recommended improvements and additional studies for BFaNS.

  18. The Pacific Marine Energy Center - South Energy Test Site (PMEC-SETS)

    Energy Technology Data Exchange (ETDEWEB)

    Batten, Belinda [Oregon State Univ., Corvallis, OR (United States); Hellin, Dan [Oregon State Univ., Corvallis, OR (United States)

    2018-02-07

    The overall goal of this project was to build on existing progress to establish the Pacific Marine Energy Center South Energy Test Site (PMEC-SETS) as the nation's first fully permitted test site for wave energy converter arrays. Specifically, it plays an essential role in reducing levelized cost of energy for the wave energy industry by providing both the facility and resources to address the challenges of cost reduction.

  19. 77 FR 21065 - Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth Group of...

    Science.gov (United States)

    2012-04-09

    ... 2070-AJ66 Certain High Production Volume Chemicals; Test Rule and Significant New Use Rule; Fourth... an opportunity to comment on a proposed test rule for 23 high production volume (HPV) chemical... necessary, to prohibit or limit that activity before it occurs. The opportunity to present oral comment was...

  20. Wave Energy Research, Testing and Demonstration Center

    Energy Technology Data Exchange (ETDEWEB)

    Batten, Belinda [Oregon State Univ., Corvallis, OR (United States)

    2014-09-30

    The purpose of this project was to build upon the research, development and testing experience of the Northwest National Marine Renewable Energy Center (NNMREC) to establish a non-grid connected open-ocean testing facility for wave energy converters (WECs) off the coast of Newport, Oregon. The test facility would serve as the first facility of its kind in the continental US with a fully energetic wave resource where WEC technologies could be proven for west coast US markets. The test facility would provide the opportunity for self-contained WEC testing or WEC testing connected via an umbilical cable to a mobile ocean test berth (MOTB). The MOTB would act as a “grid surrogate” measuring energy produced by the WEC and the environmental conditions under which the energy was produced. In order to realize this vision, the ocean site would need to be identified through outreach to community stakeholders, and then regulatory and permitting processes would be undertaken. Part of those processes would require environmental baseline studies and site analysis, including benthic, acoustic and wave resource characterization. The MOTB and its myriad systems would need to be designed and constructed.The first WEC test at the facility with the MOTB was completed within this project with the WET-NZ device in summer 2012. In summer 2013, the MOTB was deployed with load cells on its mooring lines to characterize forces on mooring systems in a variety of sea states. Throughout both testing seasons, studies were done to analyze environmental effects during testing operations. Test protocols and best management practices for open ocean operations were developed. As a result of this project, the non-grid connected fully energetic WEC test facility is operational, and the MOTB system developed provides a portable concept for WEC testing. The permitting process used provides a model for other wave energy projects, especially those in the Pacific Northwest that have similar

  1. Center Variation and the Effect of Center and Provider Characteristics on Clinical Outcomes in Kidney Transplantation: A Systematic Review of the Evidence

    Directory of Open Access Journals (Sweden)

    Anne Tsampalieros

    2017-10-01

    Full Text Available Background: Kidney transplantation is the best treatment option for patients with end-stage renal disease. While patient-level factors affecting survival are established, the presence of variation in the management of transplant recipients remains unknown. Objective: The objective of this study was to examine center variation in kidney transplantation and identify center and provider characteristics that may be associated with clinical outcomes. Design: This is a systematic review. Data sources: Ovid Medline, Embase, and Cochrane library from inception to June 2016 were used. Study eligibility: Any study examining the association between center or provider characteristics and graft or patient survival, quality of life, or functional status were included. Results: We identified 6327 records and 24 studies met eligibility. Most studies used data registries. Characteristics evaluated include center volume (n = 17, provider volume (n = 2, provider experience (n = 1, center type (n = 2, and location of follow-up (n = 1. Outcomes assessed included graft survival (n = 24 and patient survival (n = 9. Significant center variation was described in 12 of 15 and 5 of 7 studies for graft and patient survival. There was a significant and positive association between center volume and graft and patient survival in 8 and 2 studies, respectively. Provider experience and volume were significantly associated with less allograft loss and provider volume with lower risk of death. There was no association between graft survival and location of follow-up or center type. Limitations: There was substantial heterogeneity in the variables assessed and methodology used to analyze associations. Conclusion: This systematic review found center variation in kidney transplantation. Future studies in the current era are necessary to better evaluate this important topic.

  2. Final test report for traffic management data dictionary (TMDD) and related standards as deployed by the Utah department of transportation.

    Science.gov (United States)

    2008-05-23

    This report presents the results of the ITS Standards Testing Program for the field testing, assessment, and evaluation of the three volumes comprising the Standards for Traffic Management Center to Center Communications (TMDD) version 2.1 and the NT...

  3. Burn-center quality improvement: are burn outcomes dependent on admitting facilities and is there a volume-outcome "sweet-spot"?

    Science.gov (United States)

    Hranjec, Tjasa; Turrentine, Florence E; Stukenborg, George; Young, Jeffrey S; Sawyer, Robert G; Calland, James F

    2012-05-01

    Risk factors of mortality in burn patients such as inhalation injury, patient age, and percent of total body surface area (%TBSA) burned have been identified in previous publications. However, little is known about the variability of mortality outcomes between burn centers and whether the admitting facilities or facility volumes can be recognized as predictors of mortality. De-identified data from 87,665 acute burn observations obtained from the National Burn Repository between 2003 and 2007 were used to estimate a multivariable logistic regression model that could predict patient mortality with reference to the admitting burn facility/facility volume, adjusted for differences in age, inhalation injury, %TBSA burned, and an additional factor, percent full thickness burn (%FTB). As previously reported, all three covariates (%TBSA burned, inhalation injury, and age) were found to be highly statistically significant risk factors of mortality in burn patients (P value improve the multivariable model. The treatment/admitting facility was found to be an independent mortality predictor, with certain hospitals having increased odds of death and others showing a protective effect (decreased odds ratio). Hospitals with high burn volumes had the highest risk of mortality. Mortality outcomes of patients with similar risk factors (%TBSA burned, inhalation injury, age, and %FTB) are significantly affected by the treating facility and their admission volumes.

  4. Identification of risk factors for post-endoscopic retrograde cholangiopancreatography pancreatitis in a high volume center.

    Science.gov (United States)

    Phillip, Veit; Schwab, Miriam; Haf, David; Algül, Hana

    2017-01-01

    Pancreatitis is the most common complication of endoscopic retrograde cholangiopancreatography (ERCP). Several patients´ or procedure related risk factors for post-ERCP pancreatitis (PEP) have been suggested. The aim of this study was to validate the risk factors for PEP in a high-volume center. All patients undergoing first time ERCP at a tertiary referral center between December 2010 and October 2013 were retrospectively included. PEP was defined according to the Atlanta Classification. 344 patients were included in the final analysis. The risk to develop PEP was increased in patients with chronic pancreatitis (odds ratio 3.7) and after inadvertent cannulation of the pancreatic duct (odds ratio 2.2), which occurred in 26.5% of the patients. Inadvertent cannulation occurred significantly more frequently in patients with difficult cannulation of the papilla duodeni major (odds ratio 12.7; passociated with an increased risk for difficult cannulation (odds ratio 3.0). Inadvertent cannulation of the pancreatic duct is a procedure related risk factor for PEP. Measurements on preventing inadvertent cannulation of the pancreatic duct should be established and studies on prophylactic measurements should focus particularly on patients with inadvertent cannulation of the pancreatic duct.

  5. Historical sketches of Sandia National Laboratories nuclear field testing. Volume 1: Full discussion except for sensitive references

    International Nuclear Information System (INIS)

    Banister, J.R.

    1994-10-01

    This report contains historical sketches that cover the major activities of Sandia nuclear field testing, from early atmospheric shots until 1990. It includes a chronological overview followed by more complete discussions of atmospheric, high-altitude, underwater, cratering, and underground nuclear testing. Other activities related to nuclear testing and high-explosive tests are also described. A large number of references are cited for readers who wish to learn more about technical details. Appendices, written by several authors, provide more insight for a variety of special aspects of nuclear testing and related work. Two versions of this history were published: volume 1 has an unlimited distribution, and volume 2 has a limited distribution

  6. Autonomy-Enabled Fuel Savings for Military Vehicles: Report on 2016 Aberdeen Test Center Testing

    Energy Technology Data Exchange (ETDEWEB)

    Ragatz, Adam [National Renewable Energy Lab. (NREL), Golden, CO (United States); Prohaska, Robert [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gonder, Jeff [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-05-26

    Fuel savings have never been the primary focus for autonomy-enabled military vehicles. However, studies have estimated that autonomy in passenger and commercial vehicles could improve fuel economy by as much as 22%-33% over various drive cycles. If even a fraction of this saving could be realized in military vehicles, significant cost savings could be realized each year through reduced fuel transport missions, reduced fuel purchases, less maintenance, fewer required personnel, and increased vehicle range. Researchers from the National Renewable Energy Laboratory installed advanced data logging equipment and instrumentation on two autonomy-enabled convoy vehicles configured with Lockheed Martin's Autonomous Mobility Applique System to determine system performance and improve on the overall vehicle control strategies of the vehicles. Initial test results from testing conducted at the U.S. Army Aberdeen Test Center at the Aberdeen Proving Grounds are included in this report. Lessons learned from in-use testing and performance results have been provided to the project partners for continued system refinement.

  7. Test and approval center for fuel cell and hydrogen technologies: Phase I. Initiation. Final report; Test- og godkendelsescenter for braendselscelle- og brintteknologier. Fase 1. Opstart. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, A. [Technical Univ. of Denmark. DTU Energy Conversion, DTU Risoe Campus, Roskilde (Denmark)

    2012-09-15

    The aim of the present project was to initialize a Test and Approval Center for Fuel Cell and Hydrogen Technologies at the sites of the project partners Risoe DTU (Fuel Cells and Solid State Chemistry Division), and DGC (work package 1). The project furthermore included start-up of first activities with focus on the development of accelerated life-time tests of fuel cell systems, preparations for standardization of these methods, and advising in relation to certification and approval of fuel cell systems (work package 2). The main achievements of the project were: Work package 1: 1) A large national and international network was established comprising of important commercial players, research institutions, and other test centers; 2) The test center is known in large part of the international Fuel Cell and Hydrogen community due to substantial efforts in 'marketing'; 3) New national and international projects have been successfully applied for, with significant roles of the test center, which secure the further establishment and development of the center. Work package 2: 1) Testing equipment was installed and commissioned at DTU (Risoe Campus); 2) A comprehensive survey among international players regarding activities on accelerated SOFC testing was carried out; 3) A test procedure for 'compressed' testing of SOFC in relation to {mu} CHP application was developed and used for one-cell stack and 50-cell-stack testing; 4) Guidelines for Danish authority handling were formulated. (Author)

  8. Positive and negative volume-outcome relationships in the geriatric trauma population.

    Science.gov (United States)

    Matsushima, Kazuhide; Schaefer, Eric W; Won, Eugene J; Armen, Scott B; Indeck, Matthew C; Soybel, David I

    2014-04-01

    In trauma populations, improvements in outcome are documented in institutions with higher case volumes. However, it is not known whether improved outcomes are attributable to the case volume within specific higher-risk groups, such as the elderly, or to the case volume among all trauma patients treated by an institution. To test the hypothesis that outcomes of trauma care for geriatric patients are affected differently by the volume of geriatric cases and nongeriatric cases of an institution. This retrospective cohort study using a statewide trauma registry was set in state-designated levels 1 and 2 trauma centers in Pennsylvania. It included 39 431 eligible geriatric trauma patients (aged >65 years) in the Pennsylvania Trauma Outcomes Study. In-hospital mortality, major complications, and mortality after major complications (failure to rescue). Between 2001 and 2010, 39 431 geriatric trauma patients and 105 046 nongeriatric patients were captured in a review of outcomes in 20 state-designated levels 1 and 2 trauma centers. Larger volumes of geriatric trauma patients were significantly associated with lower odds of in-hospital mortality, major complications, and failure to rescue. In contrast, larger nongeriatric trauma volumes were significantly associated with higher odds of major complications in geriatric patients. Higher rates of in-hospital mortality, major complications, and failure to rescue were associated with lower volumes of geriatric trauma care and paradoxically with higher volumes of trauma care for younger patients. These findings offer the possibility that outcomes might be improved with differentiated pathways of care for geriatric trauma patients.

  9. Underground Test Area Subproject Phase I Data Analysis Task. Volume VIII - Risk Assessment Documentation Package

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-12-01

    Volume VIII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the risk assessment documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.

  10. Final Report Feasibility Study for the California Wave Energy Test Center (CalWavesm)

    Energy Technology Data Exchange (ETDEWEB)

    Blakeslee, Samuel Norman [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States). Inst. for Advanced Technology and Public Policy; Toman, William I. [Protean Wave Energy Ltd., Los Osos, CA (United States); Williams, Richard B. [Leidos Maritime Solutions, Reston, VA (United States); Davy, Douglas M. [CH2M, Sacramento, CA (United States); West, Anna [Kearns and West, Inc., San Francisco, CA (United States); Connet, Randy M. [Omega Power Engineers, LLC, Anaheim, CA (United States); Thompson, Janet [Kearns and West, Inc., San Francisco, CA (United States); Dolan, Dale [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States); Baltimore, Craig [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States); Jacobson, Paul [Electric Power Research Inst. (EPRI), Knoxville, TN (United States); Hagerman, George [Virginia Polytechnic Inst. and State Univ. (Virginia Tech), Blacksburg, VA (United States); Potter, Chris [California Natural Resources Agency, Sacramento, CA (United States); Dooher, Brendan [Pacific Gas and Electric Company, San Francisco, CA (United States); Wendt, Dean [California Polytechnic State Univ. (CalPoly), San Luis Obispo, CA (United States); Sheppard, Colin [Humboldt State Univ., Arcata, CA (United States); Harris, Andrew [Humboldt State Univ., Arcata, CA (United States); Lawson, W. Graham [Power Delivery Consultants, Inc., Albany, NY (United States)

    2017-07-31

    The California Wave Energy Test Center (CalWave) Feasibility Study project was funded over multiple phases by the Department of Energy to perform an interdisciplinary feasibility assessment to analyze the engineering, permitting, and stakeholder requirements to establish an open water, fully energetic, grid connected, wave energy test center off the coast of California for the purposes of advancing U.S. wave energy research, development, and testing capabilities. Work under this grant included wave energy resource characterization, grid impact and interconnection requirements, port infrastructure and maritime industry capability/suitability to accommodate the industry at research, demonstration and commercial scale, and macro and micro siting considerations. CalWave Phase I performed a macro-siting and down-selection process focusing on two potential test sites in California: Humboldt Bay and Vandenberg Air Force Base. This work resulted in the Vandenberg Air Force Base site being chosen as the most favorable site based on a peer reviewed criteria matrix. CalWave Phase II focused on four siting location alternatives along the Vandenberg Air Force Base coastline and culminated with a final siting down-selection. Key outcomes from this work include completion of preliminary engineering and systems integration work, a robust turnkey cost estimate, shoreside and subsea hazards assessment, storm wave analysis, lessons learned reports from several maritime disciplines, test center benchmarking as compared to existing international test sites, analysis of existing applicable environmental literature, the completion of a preliminary regulatory, permitting and licensing roadmap, robust interaction and engagement with state and federal regulatory agency personnel and local stakeholders, and the population of a Draft Federal Energy Regulatory Commission (FERC) Preliminary Application Document (PAD). Analysis of existing offshore oil and gas infrastructure was also performed

  11. NASA University Research Centers Technical Advances in Aeronautics, Space Sciences and Technology, Earth Systems Sciences, Global Hydrology, and Education. Volumes 2 and 3

    Science.gov (United States)

    Coleman, Tommy L. (Editor); White, Bettie (Editor); Goodman, Steven (Editor); Sakimoto, P. (Editor); Randolph, Lynwood (Editor); Rickman, Doug (Editor)

    1998-01-01

    This volume chronicles the proceedings of the 1998 NASA University Research Centers Technical Conference (URC-TC '98), held on February 22-25, 1998, in Huntsville, Alabama. The University Research Centers (URCS) are multidisciplinary research units established by NASA at 11 Historically Black Colleges or Universities (HBCU's) and 3 Other Minority Universities (OMU's) to conduct research work in areas of interest to NASA. The URC Technical Conferences bring together the faculty members and students from the URC's with representatives from other universities, NASA, and the aerospace industry to discuss recent advances in their fields.

  12. Theoretical test of Jarzynski's equality for reversible volume-switching processes of an ideal gas system.

    Science.gov (United States)

    Sung, Jaeyoung

    2007-07-01

    We present an exact theoretical test of Jarzynski's equality (JE) for reversible volume-switching processes of an ideal gas system. The exact analysis shows that the prediction of JE for the free energy difference is the same as the work done on the gas system during the reversible process that is dependent on the shape of path of the reversible volume-switching process.

  13. Volume totalizers analysis of pipelines operated by TRANSPETRO National Operational Control Center; Analise de totalizadores de volume em oleodutos operados pelo Centro Nacional de Controle e Operacao da TRANSPETRO

    Energy Technology Data Exchange (ETDEWEB)

    Aramaki, Thiago Lessa; Montalvao, Antonio Filipe Falcao [Petrobras Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil); Marques, Thais Carrijo [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2012-07-01

    This paper aims to present the results and methodology in the analysis of differences in volume totals used in systems such as batch tracking and leak detection of pipelines operated by the National Center for Operational Control (CNCO) at TRANSPETRO. In order to optimize this type of analysis, software was developed to acquisition and processing of historical data using the methodology developed. The methodology developed takes into account the particularities encountered in systems operated by TRANSPETRO, more specifically, by CNCO. (author)

  14. Co-infection of HIV and HBV in voluntary counseling and testing center in Abidjan

    Directory of Open Access Journals (Sweden)

    Kouassi-M ’Bengue A

    2011-12-01

    Full Text Available Objective: To evaluate the co-infection of hepatitis B virus (HBV and immune deficiency virus (HIV among clients consulting at the Voluntary Counseling and Testing Center (VCT Center of the Institut Pasteur de C ôte d ’Ivoire (IPCI. Methods: A cross-sectional study was conducted from April to June 2010 at the VCT of IPCI. All clients attending the VCT of IPCI for HIV test after having signed the informed consent form were included in the study. Venous blood samples were collected from the clients after an interview. Then the rapid tests for screening of HIV infection (Determine HIV 1/2 of Abbott and Genie II HIV-1/HIV-2, Bio-Rad were performed. As for hepatitis B surface antigen (HBsAg test, it was performed using ELISA test system using Monolisa HBsAg Ultra-Bio-Rad. Results: Of 278 samples analyzed, 30 were positive to antibody against HIV-1, giving a seroprevalence of about 10.8%, and 35 were positive to HBsAg, giving a seroprevalence of 12.6%. As for co-infection of HIV and HBV, it was 7/278 cases about 2.5%. Conclusions: It can be concluded that co-infection of HBV and HIV is relatively low among clients consulting at the VCT of the IPCI. Serological surveillance should be systematic in various HIV testing centers in the country. The use of rapid tests for detection of HBsAg allows a lot of tests to be realized. However, the choice of these tests depends on the evaluation results in reference laboratories and situation on ground.

  15. Evaluating trauma center structural performance: The experience of a Canadian provincial trauma system

    Directory of Open Access Journals (Sweden)

    Lynne Moore

    2013-01-01

    Full Text Available Background: Indicators of structure, process, and outcome are required to evaluate the performance of trauma centers to improve the quality and efficiency of care. While periodic external accreditation visits are part of most trauma systems, a quantitative indicator of structural performance has yet to be proposed. The objective of this study was to develop and validate a trauma center structural performance indicator using accreditation report data. Materials and Methods: Analyses were based on accreditation reports completed during on-site visits in the Quebec trauma system (1994-2005. Qualitative report data was retrospectively transposed onto an evaluation grid and the weighted average of grid items was used to quantify performance. The indicator of structural performance was evaluated in terms of test-retest reliability (kappa statistic, discrimination between centers (coefficient of variation, content validity (correlation with accreditation decision, designation level, and patient volume and forecasting (correlation between visits performed in 1994-1999 and 1998-2005. Results: Kappa statistics were >0.8 for 66 of the 73 (90% grid items. Mean structural performance score over 59 trauma centers was 47.4 (95% CI: 43.6-51.1. Two centers were flagged as outliers and the coefficient of variation was 31.2% (95% CI: 25.5% to 37.6%, showing good discrimination. Correlation coefficients of associations with accreditation decision, designation level, and volume were all statistically significant (r = 0.61, -0.40, and 0.24, respectively. No correlation was observed over time (r = 0.03. Conclusion: This study demonstrates the feasibility of quantifying trauma center structural performance using accreditation reports. The proposed performance indicator shows good test-retest reliability, between-center discrimination, and construct validity. The observed variability in structural performance across centers and over-time underlines the importance of

  16. Testing for Nonlinear Granger Causality in the Price-Volume Relations of Taiwan's Stock and Foreign Exchange Markets

    OpenAIRE

    Shyh-Wei Chen; Chun-Wei Chen

    2006-01-01

    This paper investigates the price-volume relationships of Taiwan's stock and foreign exchange markets. We first adopt the traditional linear Granger causality test to achieve this goal. In addition, the nonlinearity feature is also taken into account. We employ the nonlinear Granger causality test, championed by Hiemstra and Jones (1994), to detect the nonlinear relationships among stock and foreign exchange markets. The empirical results show that there do exist nonlinear price-volume relati...

  17. Test Functions for Three-Dimensional Control-Volume Mixed Finite-Element Methods on Irregular Grids

    National Research Council Canada - National Science Library

    Naff, R. L; Russell, T. F; Wilson, J. D

    2000-01-01

    .... For control-volume mixed finite-element methods, vector shape functions are used to approximate the distribution of velocities across cells and vector test functions are used to minimize the error...

  18. Human factors review of electric power dispatch control centers. Volume 3. Operator information needs summary. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.J.; Najaf-Zadeh, K.; Darlington, H.T.; McNair, H.D.; Seidenstein, S.; Williams, A.R.

    1982-10-01

    Human factors is a systems-oriented interdisciplinary specialty concerned with the design of systems, equipment, facilities and the operational environment. An important aspect leading to the design requirements is the determination of the information requirements for electric power dispatch control centers. There are significant differences between the system operator's actions during normal and degraded states of power system operation, and power system restoration. This project evaluated the information the operator requires for normal power system and control system operations and investigates the changes of information required by the operator as the power system and/or the control system degrades from a normal operating state. The Phase II study, published in two volumes, defines power system states and control system conditions to which operator information content can be related. This volume presents a summary of operator information needs, identifying the needs for and the uses of power system information by a system operator in conditions ranging from normal through degraded operation. Training requirements are also included for planning entry-level and follow-on training for operators.

  19. Satisfactory rate of postprocessing visualization of standard fetal cardiac views from 4-dimensional cardiac volumes acquired during routine ultrasound practice by experienced sonographers in peripheral centers.

    Science.gov (United States)

    Rizzo, Giuseppe; Capponi, Alessandra; Pietrolucci, Maria Elena; Capece, Giuseppe; Cimmino, Ernesto; Colosi, Enrico; Ferrentino, Salvatore; Sica, Carmine; Di Meglio, Aniello; Arduini, Domenico

    2011-01-01

    The aim of this study was to evaluate the feasibility of visualizing standard cardiac views from 4-dimensional (4D) cardiac volumes obtained at ultrasound facilities with no specific experience in fetal echocardiography. Five sonographers prospectively recorded 4D cardiac volumes starting from the 4-chamber view on 500 consecutive pregnancies at 19 to 24 weeks' gestation undergoing routine ultrasound examinations (100 pregnancies for each sonographer). Volumes were sent to the referral center, and 2 independent reviewers with experience in 4D fetal echocardiography assessed their quality in the display of the abdominal view, 4-chamber view, left and right ventricular outflow tracts, and 3-vessel and trachea view. Cardiac volumes were acquired in 474 of 500 pregnancies (94.8%). The 2 reviewers respectively acknowledged the presence of satisfactory images in 92.4% and 93.6% of abdominal views, 91.5% and 93.0% of 4-chamber views, in 85.0% and 86.2% of left ventricular outflow tracts, 83.9% and 84.5% of right ventricular outflow tracts, and 85.2% and 84.5% of 3-vessel and trachea views. The presence of a maternal body mass index of greater than 30 altered the probability of achieving satisfactory cardiac views, whereas previous maternal lower abdominal surgery did not affect the quality of reconstructed cardiac views. In conclusion, cardiac volumes acquired by 4D sonography in peripheral centers showed high enough quality to allow satisfactory diagnostic cardiac views.

  20. Test facilities for radioactive materials transport packages (Transportation Technology Center Inc., Pueblo, Colorado, USA)

    International Nuclear Information System (INIS)

    Conlon, P.C.L.

    2001-01-01

    Transportation Technology Center, Inc. is capable of conducting tests on rail vehicle systems designed for transporting radioactive materials including low level waste debris, transuranic waste, and spent nuclear fuel and high level waste. Services include rail vehicle dynamics modelling, on-track performance testing, full scale structural fatigue testing, rail vehicle impact tests, engineering design and technology consulting, and emergency response training. (author)

  1. Identification of risk factors for post-endoscopic retrograde cholangiopancreatography pancreatitis in a high volume center.

    Directory of Open Access Journals (Sweden)

    Veit Phillip

    Full Text Available Pancreatitis is the most common complication of endoscopic retrograde cholangiopancreatography (ERCP. Several patients´ or procedure related risk factors for post-ERCP pancreatitis (PEP have been suggested. The aim of this study was to validate the risk factors for PEP in a high-volume center.All patients undergoing first time ERCP at a tertiary referral center between December 2010 and October 2013 were retrospectively included. PEP was defined according to the Atlanta Classification.344 patients were included in the final analysis. The risk to develop PEP was increased in patients with chronic pancreatitis (odds ratio 3.7 and after inadvertent cannulation of the pancreatic duct (odds ratio 2.2, which occurred in 26.5% of the patients. Inadvertent cannulation occurred significantly more frequently in patients with difficult cannulation of the papilla duodeni major (odds ratio 12.7; p<0.001. ERCP on call was associated with an increased risk for difficult cannulation (odds ratio 3.0.Inadvertent cannulation of the pancreatic duct is a procedure related risk factor for PEP. Measurements on preventing inadvertent cannulation of the pancreatic duct should be established and studies on prophylactic measurements should focus particularly on patients with inadvertent cannulation of the pancreatic duct.

  2. Leak testing plan for the Oak Ridge National Laboratory liquid low-level waste systems (active tanks): Revision 2. Volume 1: Regulatory background and plan approach; Volume 2: Methods, protocols, and schedules; Volume 3: Evaluation of the ORNL/LT-823DP differential pressure leak detection method; Appendix to Revision 2: DOE/EPA/TDEC correspondence

    Energy Technology Data Exchange (ETDEWEB)

    Douglas, D.G.; Wise, R.F.; Starr, J.W.; Maresca, J.W. Jr. [Vista Research, Inc., Mountain View, CA (United States)

    1994-11-01

    This document, the Leak Testing Plan for the Oak Ridge National Laboratory Liquid Low-Level Waste System (Active Tanks), comprises three volumes. The first two volumes address the component-based leak testing plan for the liquid low-level waste system at Oak Ridge, while the third volume describes the performance evaluation of the leak detection method that will be used to test this system. Volume 1, describes that portion of the liquid low-level waste system at that will be tested; it provides the regulatory background, especially in terms of the requirements stipulated in the Federal Facilities Agreement, upon which the leak testing plan is based. Volume 1 also describes the foundation of the plan, portions of which were abstracted from existing federal documents that regulate the petroleum and hazardous chemicals industries. Finally, Volume 1 gives an overview the plan, describing the methods that will be used to test the four classes of components in the liquid low-level waste system. Volume 2 takes the general information on component classes and leak detection methods presented in Volume 1 and shows how it applies particularly to each of the individual components. A complete test plan for each of the components is presented, with emphasis placed on the methods designated for testing tanks. The protocol for testing tank systems is described, and general leak testing schedules are presented. Volume 3 describes the results of a performance evaluation completed for the leak testing method that will be used to test the small tanks at the facility (those less than 3,000 gal in capacity). Some of the details described in Volumes 1 and 2 are expected to change as additional information is obtained, as the viability of candidate release detection methods is proven in the Oak Ridge environment, and as the testing program evolves.

  3. Leak testing plan for the Oak Ridge National Laboratory liquid low-level waste systems (active tanks): Revision 2. Volume 1: Regulatory background and plan approach; Volume 2: Methods, protocols, and schedules; Volume 3: Evaluation of the ORNL/LT-823DP differential pressure leak detection method; Appendix to Revision 2: DOE/EPA/TDEC correspondence

    International Nuclear Information System (INIS)

    Douglas, D.G.; Wise, R.F.; Starr, J.W.; Maresca, J.W. Jr.

    1994-11-01

    This document, the Leak Testing Plan for the Oak Ridge National Laboratory Liquid Low-Level Waste System (Active Tanks), comprises three volumes. The first two volumes address the component-based leak testing plan for the liquid low-level waste system at Oak Ridge, while the third volume describes the performance evaluation of the leak detection method that will be used to test this system. Volume 1, describes that portion of the liquid low-level waste system at that will be tested; it provides the regulatory background, especially in terms of the requirements stipulated in the Federal Facilities Agreement, upon which the leak testing plan is based. Volume 1 also describes the foundation of the plan, portions of which were abstracted from existing federal documents that regulate the petroleum and hazardous chemicals industries. Finally, Volume 1 gives an overview the plan, describing the methods that will be used to test the four classes of components in the liquid low-level waste system. Volume 2 takes the general information on component classes and leak detection methods presented in Volume 1 and shows how it applies particularly to each of the individual components. A complete test plan for each of the components is presented, with emphasis placed on the methods designated for testing tanks. The protocol for testing tank systems is described, and general leak testing schedules are presented. Volume 3 describes the results of a performance evaluation completed for the leak testing method that will be used to test the small tanks at the facility (those less than 3,000 gal in capacity). Some of the details described in Volumes 1 and 2 are expected to change as additional information is obtained, as the viability of candidate release detection methods is proven in the Oak Ridge environment, and as the testing program evolves

  4. Development of a EUV Test Facility at the Marshall Space Flight Center

    Science.gov (United States)

    West, Edward; Pavelitz, Steve; Kobayashi, Ken; Robinson, Brian; Cirtain, Johnathan; Gaskin, Jessica; Winebarger, Amy

    2011-01-01

    This paper will describe a new EUV test facility that is being developed at the Marshall Space Flight Center (MSFC) to test EUV telescopes. Two flight programs, HiC - high resolution coronal imager (sounding rocket) and SUVI - Solar Ultraviolet Imager (GOES-R), set the requirements for this new facility. This paper will discuss those requirements, the EUV source characteristics, the wavelength resolution that is expected and the vacuum chambers (Stray Light Facility, Xray Calibration Facility and the EUV test chamber) where this facility will be used.

  5. Ocean Thermal Energy Converstion (OTEC) test facilities study program. Final report. Volume II. Part B

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-01-17

    Results are presented of an 8-month study to develop alternative non-site-specific OTEC facilities/platform requirements for an integrated OTEC test program which may include land and floating test facilities. Volume II--Appendixes is bound in three parts (A, B, and C) which together comprise a compendium of the most significant detailed data developed during the study. Part B provides an annotated test list and describes component tests and system tests.

  6. Plutonium Protection System (PPS). Volume 2. Hardware description. Final report

    International Nuclear Information System (INIS)

    Miyoshi, D.S.

    1979-05-01

    The Plutonium Protection System (PPS) is an integrated safeguards system developed by Sandia Laboratories for the Department of Energy, Office of Safeguards and Security. The system is designed to demonstrate and test concepts for the improved safeguarding of plutonium. Volume 2 of the PPS final report describes the hardware elements of the system. The major areas containing hardware elements are the vault, where plutonium is stored, the packaging room, where plutonium is packaged into Container Modules, the Security Operations Center, which controls movement of personnel, the Material Accountability Center, which maintains the system data base, and the Material Operations Center, which monitors the operating procedures in the system. References are made to documents in which details of the hardware items can be found

  7. Relation of exercise capacity with lung volumes before and after 6-minute walk test in subjects with COPD.

    Science.gov (United States)

    Wibmer, Thomas; Rüdiger, Stefan; Kropf-Sanchen, Cornelia; Stoiber, Kathrin M; Rottbauer, Wolfgang; Schumann, Christian

    2014-11-01

    There is growing evidence that exercise-induced variation in lung volumes is an important source of ventilatory limitation and is linked to exercise intolerance in COPD. The aim of this study was to compare the correlations of walk distance and lung volumes measured before and after a 6-min walk test (6MWT) in subjects with COPD. Forty-five subjects with stable COPD (mean pre-bronchodilator FEV1: 47 ± 18% predicted) underwent a 6MWT. Body plethysmography was performed immediately pre- and post-6MWT. Correlations were generally stronger between 6-min walk distance and post-6MWT lung volumes than between 6-min walk distance and pre-6MWT lung volumes, except for FEV1. These differences in Pearson correlation coefficients were significant for residual volume expressed as percent of total lung capacity (-0.67 vs -0.58, P = .043), percent of predicted residual volume expressed as percent of total lung capacity (-0.68 vs -0.59, P = .026), inspiratory vital capacity (0.65 vs 0.54, P = .019), percent of predicted inspiratory vital capacity (0.49 vs 0.38, P = .037), and percent of predicted functional residual capacity (-0.62 vs -0.47, P = .023). In subjects with stable COPD, lung volumes measured immediately after 6MWT are more closely related to exercise limitation than baseline lung volumes measured before 6MWT, except for FEV1. Therefore, pulmonary function testing immediately after exercise should be included in future studies on COPD for the assessment of exercise-induced ventilatory constraints to physical performance that cannot be adequately assessed from baseline pulmonary function testing at rest. Copyright © 2014 by Daedalus Enterprises.

  8. High Energy Performance Tests of Large Volume LaBr{sub 3}:Ce Detector

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Gondal, M.A.; Khiari, F.Z.; Dastageer, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Maslehuddin, M.M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    High energy prompt gamma ray tests of a large volume cylindrical 100 mm x 100 mm (height x diameter) LaBr{sub 3}:Ce detector were carried out using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. In this study prompt gamma-rays yield were measured from water samples contaminated with toxic elements such nickel, chromium and mercury compounds with gamma ray energies up to 10 MeV. The experimental yield of prompt gamma-rays from toxic elements were compared with the results of Monte Carlo calculations. In spite of its higher intrinsic background due to its larger volume, an excellent agreement between the experimental and calculated yields of high energy gamma-rays from Ni, Cr and Hg samples has been achieved for the large volume LaBr{sub 3}:Ce detector. (authors)

  9. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  10. Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventilation.

    Science.gov (United States)

    Lyazidi, Aissam; Thille, Arnaud W; Carteaux, Guillaume; Galia, Fabrice; Brochard, Laurent; Richard, Jean-Christophe M

    2010-12-01

    During volume-controlled ventilation, part of the volume delivered is compressed into the circuit. To correct for this phenomenon, modern ventilators use compensation algorithms. Humidity and temperature also influence the delivered volume. In a bench study at a research laboratory in a university hospital, we compared nine ICU ventilators equipped with compensation algorithms, one with a proximal pneumotachograph and one without compensation. Each ventilator was evaluated under normal, obstructive, and restrictive conditions of respiratory mechanics. For each condition, three tidal volumes (V (T)) were set (300, 500, and 800 ml), with and without an inspiratory pause. The insufflated volume and the volume delivered at the Y-piece were measured independently, without a humidification device, under ambient temperature and pressure and dry gas conditions. We computed the actually delivered V (T) to the lung under body temperature and pressure and saturated water vapour conditions (BTPS). For target V (T) values of 300, 500, and 800 ml, actually delivered V (T) under BTPS conditions ranged from 261 to 396 ml (-13 to +32%), from 437 to 622 ml (-13 to +24%), and from 681 to 953 ml (-15 to +19%), respectively (p ventilators.

  11. Trends in refractive surgery at an academic center: 2007-2009

    Directory of Open Access Journals (Sweden)

    Kuo Irene C

    2011-05-01

    Full Text Available Abstract Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK vs. laser-assisted in-situ keratomileusis (LASIK, and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10. The

  12. Trends in refractive surgery at an academic center: 2007-2009.

    Science.gov (United States)

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0

  13. FJ44 Turbofan Engine Test at NASA Glenn Research Center's Aero-Acoustic Propulsion Laboratory

    Science.gov (United States)

    Lauer, Joel T.; McAllister, Joseph; Loew, Raymond A.; Sutliff, Daniel L.; Harley, Thomas C.

    2009-01-01

    A Williams International FJ44-3A 3000-lb thrust class turbofan engine was tested in the NASA Glenn Research Center s Aero-Acoustic Propulsion Laboratory. This report presents the test set-up and documents the test conditions. Farfield directivity, in-duct unsteady pressures, duct mode data, and phased-array data were taken and are reported separately.

  14. Materials Characterization Center meeting on impact testing of waste forms. Summary report

    International Nuclear Information System (INIS)

    Merz, M.D.; Atteridge, D.; Dudder, G.

    1981-10-01

    A meeting was held on March 25-26, 1981 to discuss impact test methods for waste form materials to be used in nuclear waste repositories. The purpose of the meeting was to obtain guidance for the Materials Characterization Center (MCC) in preparing the MCC-10 Impact Test Method to be approved by the Materials Review Board. The meeting focused on two essential aspects of the test method, namely the mechanical process, or impact, used to effect rapid fracture of a waste form and the analysis technique(s) used to characterize particulates generated by the impact

  15. Demographic survey centered around the Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Richard-Haggard, K.

    1983-03-01

    Demographic data were gathered for several small population centers on and around the Nevada Test Site (NTS). Population projections were made for the three townships that include most of the major population centers in the study area, based on the share approach. These townships were Alamo Township (Lincoln County), Beatty and Pahrump townships (Nye County). It was estimated that the total population of these three townships, plus Clark County, would reach a maximum of 934,000 people by the year 2000. It was assumed that the on-site population of the NTS would continue to be a function of activity at the site, and that this would, if anything, aid in the attainment of site objectives

  16. Full-Scale Incineration System Demonstration Verification Test Burns at the Naval Battalion Construction Center, Gulfport, Mississippi. Volume 3. Treatability Tests. Part 2

    Science.gov (United States)

    1991-07-01

    treatment of TCDD in soil has great social and political appeal. Furthermore, restoration costs are reduced if excavation and transportation of the soil...tc make an informed decision. Very truly Yours, f . ..... c Naval Constructione - ic:Commanding Of2icer 3C;~ Navl CnstuctonBattalion Center Gulfoort...EfPLOYES NAME (Print) SOCIAL SECURITY NU!BER EMPLOYEE SIGNATURE • 1LOCRA0 AID * tup, .tmn 60 John Glenn Drive, Suite 104 Audubon Industrial Park, North

  17. Underground Test Area Subproject Phase I Data Analysis Task. Volume VII - Tritium Transport Model Documentation Package

    Energy Technology Data Exchange (ETDEWEB)

    None

    1996-12-01

    Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.

  18. Prototypical Rod Construction Demonstration Project. Phase 3, Final report: Volume 1, Cold checkout test report, Book 3

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 3 discusses the following topics: Downender Test Results and Analysis Report; NFBC Canister Upender Test Results and Analysis Report; Fuel Assembly Handling Fixture Test Results and Analysis Report; and Fuel Canister Upender Test Results and Analysis Report.

  19. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Science.gov (United States)

    Ristagno, Giuseppe; Beluffi, Simonetta; Tanzi, Dario; Belloli, Federica; Carmagnini, Paola; Croci, Massimo; D’Aviri, Giuseppe; Menasce, Guido; Pastore, Juan C.; Pellanda, Armando; Pollini, Alberto; Savoia, Giorgio

    2018-01-01

    (1) Background: This study evaluated the perioperative red blood cell (RBC) transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2) Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3) Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6%) required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008), significantly older, with a higher ASA grade (p = 0.0002), and with lower pre-surgery hemoglobin (HB) level and hematocrit (p < 0.0001). In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI) 2.84 (2.11–3.82)), a higher ASA class (1.77 (1.03–3.05)) and a longer operative time (1.02 (1.01–1.02)) were independently associated with RBC transfusion. (4) Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation. PMID:29385760

  20. Red Blood Cell Transfusion Need for Elective Primary Posterior Lumbar Fusion in A High-Volume Center for Spine Surgery

    Directory of Open Access Journals (Sweden)

    Giuseppe Ristagno

    2018-01-01

    Full Text Available (1 Background: This study evaluated the perioperative red blood cell (RBC transfusion need and determined predictors for transfusion in patients undergoing elective primary lumbar posterior spine fusion in a high-volume center for spine surgery. (2 Methods: Data from all patients undergoing spine surgery between 1 January 2014 and 31 December 2016 were reviewed. Patients’ demographics and comorbidities, perioperative laboratory results, and operative time were analyzed in relation to RBC transfusion. Multivariate logistic regression analysis was performed to identify the predictors of transfusion. (3 Results: A total of 874 elective surgeries for primary spine fusion were performed over the three years. Only 54 cases (6% required RBC transfusion. Compared to the non-transfused patients, transfused patients were mainly female (p = 0.0008, significantly older, with a higher ASA grade (p = 0.0002, and with lower pre-surgery hemoglobin (HB level and hematocrit (p < 0.0001. In the multivariate logistic regression, a lower pre-surgery HB (OR (95% CI 2.84 (2.11–3.82, a higher ASA class (1.77 (1.03–3.05 and a longer operative time (1.02 (1.01–1.02 were independently associated with RBC transfusion. (4 Conclusions: In the instance of elective surgery for primary posterior lumbar fusion in a high-volume center for spine surgery, the need for RBC transfusion is low. Factors anticipating transfusion should be taken into consideration in the patient’s pre-surgery preparation.

  1. Workforce Retention Study in support of the U.S. Army Aberdeen Test Center human capital management strategy

    OpenAIRE

    Fore, Richard; Hacker, Kelly; Reedy, Michael; Sanchez-Vahamonde, Kristi; Whelan, Sean

    2016-01-01

    Approved for public release; distribution is unlimited In Fiscal Year 15, the U.S. Army Aberdeen Test Center (ATC) experienced an attrition rate of 10.4% of its civilian workforce. Without mitigation, the current employee turnover could result in a loss of organizational knowledge, reduction in the number of highly skilled test center employees, and a failure for ATC to meet mission objectives, namely the execution of rigorous testing to support Department of Defense acquisition programs. ...

  2. New Pathways for Primary Care: An Update on Primary Care Programs From the Innovation Center at CMS

    Science.gov (United States)

    Baron, Richard J.

    2012-01-01

    Those in practice find that the fee-for-service system does not adequately value the contributions made by primary care. The Center for Medicare and Medicaid Innovation (Innovation Center) was created by the Affordable Care Act to test new models of health care delivery to improve the quality of care while lowering costs. All programs coming out of the Innovation Center are tests of new payment and service delivery models. By changing both payment and delivery models and moving to a payment model that rewards physicians for quality of care instead of volume of care, we may be able to achieve the kind of health care patients want to receive and primary care physicians want to provide. PMID:22412007

  3. Reference Material Kydex(registered trademark)-100 Test Data Message for Flammability Testing

    Science.gov (United States)

    Engel, Carl D.; Richardson, Erin; Davis, Eddie

    2003-01-01

    The Marshall Space Flight Center (MSFC) Materials and Processes Technical Information System (MAPTIS) database contains, as an engineering resource, a large amount of material test data carefully obtained and recorded over a number of years. Flammability test data obtained using Test 1 of NASA-STD-6001 is a significant component of this database. NASA-STD-6001 recommends that Kydex 100 be used as a reference material for testing certification and for comparison between test facilities in the round-robin certification testing that occurs every 2 years. As a result of these regular activities, a large volume of test data is recorded within the MAPTIS database. The activity described in this technical report was undertaken to mine the database, recover flammability (Test 1) Kydex 100 data, and review the lessons learned from analysis of these data.

  4. Human factors review of electric power dispatch control centers. Volume 4. Operator information needs. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R.J.; Najaf-Zadeh, K.; Darlington, H.T.; McNair, H.D.; Seidenstein, S.; Williams, A.R.

    1982-10-01

    Human factors is a systems-oriented interdisciplinary specialty concerned with the design of systems, equipment, facilities and the operational environment. An important aspect leading to the design requirements is the determination of the information requirements for electric power dispatch control centers. There are significant differences between the system operator's actions during normal and degraded states of power system operation, and power system restoration. This project evaluated the information the operator requires for normal power system and control system operations and investigates the changes of information required by the operator as the power system and/or the control system degrades from a normal operating state. The Phase II study, published in two volumes, defines power system states and control system conditions to which operator information content can be related. This volume presents detailed data concerning operator information needs that identify the needs for and the uses of power system information by a system operator in conditions ranging from normal through degraded operation. The study defines power system states and control system conditions to which operator information content can be related, and it identifies the requisite information as consistent with current industry practice so as to aid control system designers. Training requirements are also included for planning entry-level and follow-on training for operators.

  5. De-hospitalization of the pediatric day surgery by means of a freestanding surgery center: pilot study in the lazio region

    Directory of Open Access Journals (Sweden)

    Mangia Giovanni

    2012-02-01

    Full Text Available Abstract Background Day surgery should take place in appropriate organizational settings. In the presence of high volumes, the organizational models of the Lazio Region are represented by either Day Surgery Units within continuous-cycle hospitals or day-cycle Day Surgery Centers. This pilot study presents the regional volumes provided in 2010 and the additional volumes that could be provided based on the best performance criterion with a view to suggesting the setting up of a regional Freestanding Center of Pediatric Day Surgery. Methods This is an observational retrospective study. The activity volumes have been assessed by means of a DRG (Diagnosis Related Group-specific indicator that measures the ratio of outpatients to the total number of treated patients (freestanding indicator, FI. The included DRGs had an FI exceeding the 3rd quartile present in at least a health-care facility and a volume exceeding 0.5% of the total patients of the pediatric surgery and urology facilities of the Lazio Region. The relevant data have been provided by the Public Health Agency and relate to 2010. The best performance FI has been used to calculate the theoretical volume of transferability of the remaining facilities into freestanding surgery centers. Patients under six months of age and DRGs common to other disciplines have been excluded. The Chi Square test has been used to compare the FI of the health-care facilities and the FI of the places of origin of the patients. Results The DRG provided in 2010 amounted to a total of 5768 belonging to 121 types of procedures. The application of the criteria of inclusion have led to the selection of seven final DRG categories of minor surgery amounting to 3522 cases. Out of this total number, there were 2828 outpatients and 694 inpatients. The recourse of the best performance determines a potential transfer of 497 cases. The total outpatient volume is 57%. The Chi Square test has pointed to a statistically significant

  6. NASA Engineering and Safety Center (NESC) Enhanced Melamine (ML) Foam Acoustic Test (NEMFAT)

    Science.gov (United States)

    McNelis, Anne M.; Hughes, William O.; McNelis, Mark E.

    2014-01-01

    The NASA Engineering and Safety Center (NESC) funded a proposal to achieve initial basic acoustic characterization of ML (melamine) foam, which could serve as a starting point for a future, more comprehensive acoustic test program for ML foam. A project plan was developed and implemented to obtain acoustic test data for both normal and enhanced ML foam. This project became known as the NESC Enhanced Melamine Foam Acoustic Test (NEMFAT). This document contains the outcome of the NEMFAT project.

  7. Knowledge of HIV Testing Guidelines Among US Internal Medicine Residents: A Decade After the Centers for Disease Control and Prevention's Routine HIV Testing Recommendations.

    Science.gov (United States)

    Dandachi, Dima; Dang, Bich N; Wilson Dib, Rita; Friedman, Harvey; Giordano, Thomas

    2018-05-01

    Ten years after the Centers for Disease Control and Prevention recommended universal HIV screening, rates remain low. Internal medicine residents are the front-line medical providers for large groups of patients. We evaluated the knowledge of internal medicine residents about HIV testing guidelines and examined adherence to universal HIV testing in an outpatient setting. A cross-sectional survey of internal medicine residents at four residency programs in Chicago was conducted from January to March 2016. Aggregate data on HIV screening were collected from 35 federally qualified community health centers in the Chicago area after inclusion of an HIV testing best practice alert in patients' electronic medical records. Of the 192 residents surveyed, 130 (68%) completed the survey. Only 58% were aware of universal HIV screening and 49% were aware that Illinois law allows for an opt-out HIV testing strategy. Most of the residents (64%) ordered no more than 10 HIV tests in 6 months. The most frequently reported barriers to HIV testing were deferral because of urgent care issues, lack of time, and the perception that patients were uncomfortable discussing HIV testing. From July 2015 to February 2016, the average HIV testing adherence rate in the 35 health centers was 18.2%. More effort is needed to change HIV testing practices among internal medicine residents so that they will adopt this approach in their future clinical practice. Improving knowledge about HIV testing and addressing other HIV testing barriers are essential for such a successful change.

  8. Safety and efficacy of bariatric surgery in Mexico: A detailed analysis of 500 surgeries performed at a high-volume center.

    Science.gov (United States)

    Guilbert, L; Joo, P; Ortiz, C; Sepúlveda, E; Alabi, F; León, A; Piña, T; Zerrweck, C

    2018-06-19

    Bariatric surgery is the best method for treating obesity and its comorbidities. Our aim was to provide a detailed analysis of the perioperative outcomes in Mexican patients that underwent surgery at a high-volume hospital center. A retrospective study was conducted on all the patients that underwent bariatric surgery at a single hospital center within a time frame of 4 and one-half years. Demographics, the perioperative variables, complications (early and late), weight loss, failure, and type 2 diabetes mellitus remission were all analyzed. Five hundred patients were included in the study, 83.2% of whom were women. Mean patient age was 38.8 years and BMI was 44.1kg/m 2 . The most common comorbidities were high blood pressure, dyslipidemia, and diabetes. Laparoscopic gastric bypass surgery was performed in 85.8% of the patients, sleeve gastrectomy in 13%, and revision surgeries in 1%. There were 9.8% early complications and 12.2% late ones, with no deaths. Overall weight loss as the excess weight loss percentage at 12 and 24 months was 76.9 and 77.6%. The greatest weight loss at 12 months was seen in the patients that underwent laparoscopic gastric bypass. A total of 11.4% of the patients had treatment failure. In the patients with type 2 diabetes mellitus, 68.7% presented with complete disease remission and 9.3% with partial remission. There was improvement in 21.8% of the cases. In our experience at a high-volume hospital center, bariatric surgery is safe and effective, based on the low number of adverse effects and consequent weight loss and type 2 diabetes mellitus control. Long-term studies with a larger number of patients are needed to determine the final impact of those procedures. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  9. Prehospital tidal volume influences hospital tidal volume: A cohort study.

    Science.gov (United States)

    Stoltze, Andrew J; Wong, Terrence S; Harland, Karisa K; Ahmed, Azeemuddin; Fuller, Brian M; Mohr, Nicholas M

    2015-06-01

    The purposes of the study are to describe current practice of ventilation in a modern air medical system and to measure the association of ventilation strategy with subsequent ventilator care and acute respiratory distress syndrome (ARDS). Retrospective observational cohort study of intubated adult patients (n = 235) transported by a university-affiliated air medical transport service to a 711-bed tertiary academic center between July 2011 and May 2013. Low tidal volume ventilation was defined as tidal volumes less than or equal to 8 mL/kg predicted body weight. Multivariable regression was used to measure the association between prehospital tidal volume, hospital ventilation strategy, and ARDS. Most patients (57%) were ventilated solely with bag valve ventilation during transport. Mean tidal volume of mechanically ventilated patients was 8.6 mL/kg predicted body weight (SD, 0.2 mL/kg). Low tidal volume ventilation was used in 13% of patients. Patients receiving low tidal volume ventilation during air medical transport were more likely to receive low tidal volume ventilation in the emergency department (P tidal volume (P = .840). Low tidal volume ventilation was rare during air medical transport. Air transport ventilation strategy influenced subsequent ventilation but was not associated with ARDS. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Fuel Line: Defense Energy Support Center. Volume 2

    National Research Council Canada - National Science Library

    2000-01-01

    .... Fuel Line is prepared by desktop publishing applications and designed to provide timely, factual information on policies, plans, operations, and technical developments of the Center and interrelated subject matter...

  11. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Leinhard, Olof Dahlqvist [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Medical and Health Sciences, Linkoeping (Sweden); Karlsson, Anette; Borga, Magnus [Linkoeping University, Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping University, Department of Biomedical Engineering, Linkoeping (Sweden); Rosander, Johannes [Advanced MR Analytics AB, Linkoeping (Sweden); Toms, Andoni P. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich (United Kingdom); Radiology Academy, Cotman Centre, Norwich, Norfolk (United Kingdom)

    2014-09-15

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  12. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system

    International Nuclear Information System (INIS)

    Thomas, Marianna S.; Newman, David; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N.; Leinhard, Olof Dahlqvist; Karlsson, Anette; Borga, Magnus; Rosander, Johannes; Toms, Andoni P.

    2014-01-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19.32 L (SD9.1) and 19.28 L (SD9.12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1.0, 95 % level of agreement -0.32-0.2 L). ICC for all automated test-retest muscle volumes were almost perfect (0.99-1.0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1.68 L (2SD0.6) compared to automated 1.64 L (2SD 0.6), left lower leg: manual 1.69 L (2SD 0.64) compared to automated 1.63 L (SD0.61), correlation coefficients for automated and manual segmentation were 0.94-0.96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. (orig.)

  13. Computer-aided dispatch--traffic management center field operational test : Washington State final report

    Science.gov (United States)

    2006-05-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...

  14. Marshall Space Flight Center's Impact Testing Facility Capabilities

    Science.gov (United States)

    Finchum, Andy; Hubbs, Whitney; Evans, Steve

    2008-01-01

    Marshall Space Flight Center s (MSFC) Impact Testing Facility (ITF) serves as an important installation for space and missile related materials science research. The ITF was established and began its research in spacecraft debris shielding in the early 1960s, then played a major role in the International Space Station debris shield development. As NASA became more interested in launch debris and in-flight impact concerns, the ITF grew to include research in a variety of impact genres. Collaborative partnerships with the DoD led to a wider range of impact capabilities being relocated to MSFC as a result of the closure of Particle Impact Facilities in Santa Barbara, California. The Particle Impact Facility had a 30 year history in providing evaluations of aerospace materials and components during flights through rain, ice, and solid particle environments at subsonic through hypersonic velocities. The facility s unique capabilities were deemed a "National Asset" by the DoD. The ITF now has capabilities including environmental, ballistic, and hypervelocity impact testing utilizing an array of air, powder, and two-stage light gas guns to accommodate a variety of projectile and target types and sizes. Numerous upgrades including new instrumentation, triggering circuitry, high speed photography, and optimized sabot designs have been implemented. Other recent research has included rain drop demise characterization tests to obtain data for inclusion in on-going model development. The current and proposed ITF capabilities range from rain to micrometeoroids allowing the widest test parameter range possible for materials investigations in support of space, atmospheric, and ground environments. These test capabilities including hydrometeor, single/multi-particle, ballistic gas guns, exploding wire gun, and light gas guns combined with Smooth Particle Hydrodynamics Code (SPHC) simulations represent the widest range of impact test capabilities in the country.

  15. Center for Epidemiologic Studies Depression Scale for Children: psychometric testing of the Chinese version.

    Science.gov (United States)

    Li, Ho Cheung William; Chung, Oi Kwan Joyce; Ho, Ka Yan

    2010-11-01

    This paper is a report of psychometric testing of the Chinese version of the Center for Epidemiologic Studies Depression Scale for Children. The availability of a valid and reliable instrument that accurately detects depressive symptoms in children is crucial before any psychological intervention can be appropriately planned and evaluated. There is no such an instrument for Chinese children. A test-retest, within-subjects design was used. A total of 313 primary school students between the ages of 8 and 12 years were invited to participate in the study in 2009. Participants were asked to respond to the Chinese version of the Center for Epidemiologic Studies Depression Scale for Children, short form of the State Anxiety Scale for Children and Rosenberg's Self-Esteem Scale. The internal consistency, content validity and construct validity and test-retest reliability of the Chinese version of the Center for Epidemiologic Studies Depression Scale for Children were assessed. The newly-translated scale demonstrated adequate internal consistency, good content validity and appropriate convergent and discriminant validity. Confirmatory factor analysis added further evidence of the construct validity of the scale. Results suggest that the newly-translated scale can be used as a self-report assessment tool in detecting depressive symptoms of Chinese children aged between 8 and 12 years. © 2010 Blackwell Publishing Ltd.

  16. Test of s-wave pairing in heavy-fermion systems due to Kondo volume collapse

    International Nuclear Information System (INIS)

    Svozil, K.

    1987-01-01

    It is proposed to utilize resonant Raman scattering on heavy-fermion superconductors as a test for Cooper pairing via an effective phonon-mediated attraction due to the Kondo volume collapse. The suggested experiment might help to discriminate between singlet and triplet pairing

  17. Armstrong Flight Research Center Flight Test Capabilities and Opportunities for the Applications of Wireless Data Acquisition Systems

    Science.gov (United States)

    Hang, Richard

    2015-01-01

    The presentation will overview NASA Armstrong Flight Research Centers flight test capabilities, which can provide various means for flight testing of passive and active wireless sensor systems, also, it will address the needs of the wireless data acquisition solutions for the centers flight instrumentation issues such as additional weight caused by added instrumentation wire bundles, connectors, wire cables routing, moving components, etc., that the Passive Wireless Sensor Technology Workshop may help. The presentation shows the constraints and requirements that the wireless sensor systems will face in the flight test applications.

  18. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    Science.gov (United States)

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  19. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

  20. 76 FR 1067 - Testing of Certain High Production Volume Chemicals; Second Group of Chemicals

    Science.gov (United States)

    2011-01-07

    ... Mfg & NOES (number based criteria based criteria significant chemicals (lbs) industrial of workers... 2070-AD16 Testing of Certain High Production Volume Chemicals; Second Group of Chemicals AGENCY... section 4(a)(1)(B) of the Toxic Substances Control Act (TSCA) to require manufacturers, importers, and...

  1. The design, development, and test of balloonborne and groundbased lidar systems. Volume 1: Balloonborne coherent CO2 lidar system

    Science.gov (United States)

    Shepherd, O.; Aurilio, G.; Bucknam, R. D.; Hurd, A. G.; Rappaport, S. A.

    1991-06-01

    This is Volume 1 of a three volume final report on the design, development, and test of balloonborne and groundbased lidar systems. Volume 2 describes the flight test of Atmospheric Balloonborne Lidar Experiment, ABLE 2, which successfully made atmospheric density backscatter measurements during a flight over White Sands Missile Range. Volume 3 describes groundbased lidar development and measurements, including the design of a telescope dome lidar installation, the design of a transportable lidar shed for remote field sites, and field measurements of atmospheric and cloud backscatter from Ascension Island during SABLE 89 and Terciera, Azores during GABLE 90. In this volume, Volume 1, the design and fabrication of a balloonborne CO2 coherent lidar payload are described. The purpose of this payload is to measure, from altitudes greater than 20 km, the 10.6 micrometers backscatter from atmospheric aerosols as a function of altitude. Minor modifications to the lidar would provide for aerosol velocity measurements to be made. The lidar and payload system design was completed, and major components were fabricated and assembled. These tasks have been successfully completed, and recommendations for further lidar measurements and data analysis have been made.

  2. C-Band Airport Surface Communications System Standards Development. Phase II Final Report. Volume 2: Test Bed Performance Evaluation and Final AeroMACS Recommendations

    Science.gov (United States)

    Hall, Edward; Magner, James

    2011-01-01

    This report is provided as part of ITT s NASA Glenn Research Center Aerospace Communication Systems Technical Support (ACSTS) contract NNC05CA85C, Task 7: New ATM Requirements-Future Communications, C-Band and L-Band Communications Standard Development and was based on direction provided by FAA project-level agreements for New ATM Requirements-Future Communications. Task 7 included two subtasks. Subtask 7-1 addressed C-band (5091- to 5150-MHz) airport surface data communications standards development, systems engineering, test bed and prototype development, and tests and demonstrations to establish operational capability for the Aeronautical Mobile Airport Communications System (AeroMACS). Subtask 7-2 focused on systems engineering and development support of the L-band digital aeronautical communications system (L-DACS). Subtask 7-1 consisted of two phases. Phase I included development of AeroMACS concepts of use, requirements, architecture, and initial high-level safety risk assessment. Phase II builds on Phase I results and is presented in two volumes. Volume I is devoted to concepts of use, system requirements, and architecture, including AeroMACS design considerations. Volume II (this document) describes an AeroMACS prototype evaluation and presents final AeroMACS recommendations. This report also describes airport categorization and channelization methodologies. The purposes of the airport categorization task were (1) to facilitate initial AeroMACS architecture designs and enable budgetary projections by creating a set of airport categories based on common airport characteristics and design objectives, and (2) to offer high-level guidance to potential AeroMACS technology and policy development sponsors and service providers. A channelization plan methodology was developed because a common global methodology is needed to assure seamless interoperability among diverse AeroMACS services potentially supplied by multiple service providers.

  3. Applying reliability centered maintenance analysis principles to inservice testing

    International Nuclear Information System (INIS)

    Flude, J.W.

    1994-01-01

    Federal regulations require nuclear power plants to use inservice test (IST) programs to ensure the operability of safety-related equipment. IST programs are based on American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code requirements. Many of these plants also use Reliability Centered Maintenance (RCM) to optimize system maintenance. ASME Code requirements are hard to change. The process for requesting authority to use an alternate strategy is long and expensive. The difficulties of obtaining this authority make the use of RCM method on safety-related systems not cost effective. An ASME research task force on Risk Based Inservice Testing is investigating changing the Code. The change will allow plants to apply RCM methods to the problem of maintenance strategy selection for safety-related systems. The research task force is working closely with the Codes and Standards sections to develop a process related to the RCM process. Some day plants will be able to use this process to develop more efficient and safer maintenance strategies

  4. Evaluation of Introduction of a Delayed Cord Clamping Protocol for Premature Neonates in a High-Volume Maternity Center.

    Science.gov (United States)

    Liu, Lilly Y; Feinglass, Joe M; Khan, Janine Y; Gerber, Susan E; Grobman, William A; Yee, Lynn M

    2017-05-01

    To evaluate adherence to a delayed cord clamping protocol for preterm births in the first 2 years after its introduction, perform a quality improvement assessment, and determine neonatal outcomes associated with protocol implementation and adherence. This is a retrospective cohort study of women delivering singleton neonates at 23-32 weeks of gestation in the 2 years before (preprotocol) and 2 years after (postprotocol) introduction of a 30-second delayed cord clamping protocol at a large-volume academic center. This policy was communicated to obstetric and pediatric health care providers and nurses and reinforced with intermittent educational reviews. Barriers to receiving delayed cord clamping were assessed using χ tests and multivariable logistic regression. Neonatal outcomes then were compared between all neonates in the preprotocol period and all neonates in the postprotocol period and between all neonates in the preprotocol period and neonates receiving delayed cord clamping in the postprotocol period using multivariable linear and logistic regression analyses. Of the 427 eligible neonates, 187 were born postprotocol. Of these, 53.5% (n=100) neonates received delayed cord clamping according to the protocol. The rate of delayed cord clamping preprotocol was 0%. Protocol uptake and frequency of delayed cord clamping increased over the 2 years after its introduction. In the postprotocol period, cesarean delivery was the only factor independently associated with failing to receive delayed cord clamping (adjusted odds ratio [OR] 0.49, 95% confidence interval [CI] 0.25-0.96). In comparison with the preprotocol period, those who received delayed cord clamping in the postprotocol period had significantly higher birth hematocrit (β=2.46, P=.007) and fewer blood transfusions in the first week of life (adjusted OR 0.49, 95% CI 0.25-0.96). After introduction of an institutional delayed cord clamping protocol followed by continued health care provider education and

  5. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 72, RHIC SPIN COLLABORATION MEETINGS XXXI, XXXII, XXXIII

    International Nuclear Information System (INIS)

    OGAWA, A.

    2005-01-01

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkyusho'' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists. A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are seventy-two proceeding volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  6. Contaminated metallic melt volume reduction testing

    International Nuclear Information System (INIS)

    Deichman, J.L.

    1981-01-01

    Laboratory scale metallic melts (stainless steel) were accomplished in support of Decontamination and Decommissioning's (D and D) contaminated equipment volume reduction and Low-Level Lead Site Waste programs. Six laboratory scale melts made with contaminated stainless steel provided data that radionuclide distribution can be predicted when proper temperature rates and ranges are employed, and that major decontamination occurs with the use of designed slagging materials. Stainless steel bars were contaminated with plutonium, cobalt, cesium and europium. This study was limited to stainless steel, however, further study is desirable to establish data for other metals and alloys. This study represents a positive beginning in defining the feasibility of economical volume reduction or conversion from TRU waste forms to LLW forms for a large portion of approximately 50 thousand tons of contaminated metal waste now being stored at Hanford underground or in deactivated facilities

  7. The E-3 Test Facility at Stennis Space Center: Research and Development Testing for Cryogenic and Storable Propellant Combustion Systems

    Science.gov (United States)

    Pazos, John T.; Chandler, Craig A.; Raines, Nickey G.

    2009-01-01

    This paper will provide the reader a broad overview of the current upgraded capabilities of NASA's John C. Stennis Space Center E-3 Test Facility to perform testing for rocket engine combustion systems and components using liquid and gaseous oxygen, gaseous and liquid methane, gaseous hydrogen, hydrocarbon based fuels, hydrogen peroxide, high pressure water and various inert fluids. Details of propellant system capabilities will be highlighted as well as their application to recent test programs and accomplishments. Data acquisition and control, test monitoring, systems engineering and test processes will be discussed as part of the total capability of E-3 to provide affordable alternatives for subscale to full scale testing for many different requirements in the propulsion community.

  8. Analysis of Daily Laboratory Orders at a Large Urban Academic Center: A Multifaceted Approach to Changing Test Ordering Patterns.

    Science.gov (United States)

    Rudolf, Joseph W; Dighe, Anand S; Coley, Christopher M; Kamis, Irina K; Wertheim, Bradley M; Wright, Douglas E; Lewandrowski, Kent B; Baron, Jason M

    2017-08-01

    We sought to address concerns regarding recurring inpatient laboratory test order practices (daily laboratory tests) through a multifaceted approach to changing ordering patterns. We engaged in an interdepartmental collaboration to foster mindful test ordering through clinical policy creation, electronic clinical decision support, and continuous auditing and feedback. Annualized daily order volumes decreased from approximately 25,000 to 10,000 during a 33-month postintervention review. This represented a significant change from preintervention order volumes (95% confidence interval, 0.61-0.64; P < 10-16). Total inpatient test volumes were not affected. Durable changes to inpatient order practices can be achieved through a collaborative approach to utilization management that includes shared responsibility for establishing clinical guidelines and electronic decision support. Our experience suggests auditing and continued feedback are additional crucial components to changing ordering behavior. Curtailing daily orders alone may not be a sufficient strategy to reduce in-laboratory costs. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 1: The manual

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. The first volume sets out the Modern Coal Testing Methods in summarised form that can be used as a quick guide to practitioners to assist in selecting the best technique to solve their problems.

  10. Laser Spot Center Detection and Comparison Test

    Science.gov (United States)

    Zhu, Jun; Xu, Zhengjie; Fu, Deli; Hu, Cong

    2018-04-01

    High efficiency and precision of the pot center detection are the foundations of avionics instrument navigation and optics measurement basis for many applications. It has noticeable impact on overall system performance. Among them, laser spot detection is very important in the optical measurement technology. In order to improve the low accuracy of the spot center position, the algorithm is improved on the basis of the circle fitting. The pretreatment is used by circle fitting, and the improved adaptive denoising filter for TV repair technology can effectively improves the accuracy of the spot center position. At the same time, the pretreatment and de-noising can effectively reduce the influence of Gaussian white noise, which enhances the anti-jamming capability.

  11. Thirty Years of Pancreas Transplantation at Leiden University Medical Center : Long-Term Follow-Up in a Large Eurotransplant Center

    NARCIS (Netherlands)

    Kopp, Wouter H; Verhagen, Merel J J; Blok, Joris J; Huurman, Volkert A L; de Fijter, Johan W; de Koning, Eelco J; Putter, Hein; Baranski, Andzrej G; Schaapherder, Alexander F M; Braat, Andries E; Ringers, Jan

    2015-01-01

    BACKGROUND: An overview of 30 years of pancreas transplantation at a high volume center. Analysis of patient survival- and graft survival-associated risk factors. METHODS: All pancreas transplantations performed in our center from January 1, 1984, till December 31, 2012, were evaluated. Covariates

  12. User-centered design and usability testing of an innovative health-related quality of life module.

    Science.gov (United States)

    Nagykaldi, Z J; Jordan, M; Quitoriano, J; Ciro, C A; Mold, J W

    2014-01-01

    Various computerized health risk appraisals (HRAs) are available, but few of them assess health-related quality of life (HRQoL) in a goal-directed framework. This study describes the user-centered development and usability testing of an innovative HRQoL module that extends a validated HRA tool in primary care settings. Systematic user-centered design, usability testing, and qualitative methods were used to develop the HRQoL module in primary care practices. Twenty two patients and 5 clinicians participated in two rounds of interactive technology think-out-loud sessions (TOLs) and semi-structured interviews (SSIs) to iteratively develop a four-step, computerized process that collects information on patient goals for meaningful life activities and current level of disability and presents a personalized and prioritized list of preventive recommendations linked to online resources. Analysis of TOLs and SSIs generated 5 categories and 11 sub-categories related to facilitators and barriers to usability and human-technology interaction. The categories included: Understanding the Purpose, Usability, Perceived Value, Literacy, and Participant Motivation. Some categories were inter-connected. The technology was continually and iteratively improved between sessions until saturation of positive feedback was achieved in 4 categories (addressing motivation will require more research). Usability of all screen units of the module was improved substantially. Clinician feedback emphasized the importance of the module's ability to translate the patient-centered HRQoL Report into actionable items for clinicians to facilitate shared decision-making. Complete integration of the HRQoL module into the existing HRA will require further development and testing. Systematic application of user-centered design and human factors principles in technology development and testing may significantly improve the usability and clinical value of health information systems. This more sophisticated

  13. Systems Book for a Student Information System. End of Project Report, 1968-1971, Volume II.

    Science.gov (United States)

    Western Nevada Regional Education Center, Lovelock.

    The necessary handbooks for use of the Student Information System (SIS), developed and tested by the Western Nevada Regional Education Center under a 1968-71 Title III (Elementary and Secondary Education Act) grant, are presented in this volume. As noted, the purpose of the SIS is to supply data and information to persons or organizations who make…

  14. Space and Missile Systems Center Standard: Test Requirements for Launch, Upper-Stage and Space Vehicles

    Science.gov (United States)

    2014-09-05

    Aviation Blvd. El Segundo, CA 90245 4. This standard has been approved for use on all Space and Missile Systems Center/Air Force Program...140 Satellite Hardness and Survivability; Testing Rationale for Electronic Upset and Burnout Effects 30. JANNAF-GL-2012-01-RO Test and Evaluation...vehicle, subsystem, and unit lev- els . Acceptance testing shall be conducted on all subsequent flight items. The protoqualification strategy shall require

  15. Computer-aided dispatch--traffic management center field operational test : state of Utah final report

    Science.gov (United States)

    2006-07-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...

  16. US DOE Regional Test Centers Program - 2016 Annual Report.

    Energy Technology Data Exchange (ETDEWEB)

    Stein, Joshua [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    The US Department of Energy’s Regional Test Center (RTC) program provides outdoor validation and bankability data for innovative solar technologies at five sites across the US representing a range of climate conditions. Data helps get new technologies to market faster and improves US industry competitiveness. Managed by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL), the RTC program partners with US manufacturers of photovoltaic (PV) technologies, including modules, inverters, and balance-of-system equipment. The study is collaborative, with manufacturers (also known as RTC industry partners) and the national labs working together on a system design and validation strategy that meets a clearly defined set of performance and reliability objectives.

  17. Vehicle Test Facilities at Aberdeen Test Center and Yuma Test Center

    Science.gov (United States)

    2012-02-27

    fiber optic and bi-directional microwave telemetry links that provide high speed data transfer and real-time test control, and secure, single...Patton Hilly Trails is a 4.2 km (2.6 mi) loop course situated on a Basalt Hill Range site which is located on a series of relic beach terraces. The...Mountain and consists of primarily stretches of very cobbled surface interspersed with rock outcrops and bedrock. The course terrain is basalt hills

  18. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients.

    Science.gov (United States)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte; Warming, Susan

    2017-12-01

    Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted due to acute illness, we aimed to determine the interrater reliability of the V-VST in this clinical setting. Reporting in this study is in accordance with proposed guidelines for the reporting of reliability and agreement studies (GRRAS). In three Danish hospitals (CRD-BFH, CRD-GH, NDR-H) 11 skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who administrated the test in an order based on randomization, blinded to each other's results. Agreement, Kappa values, weighed Kappa values and Kappa adjusted for bias and prevalence are reported. The interrater reliability of V-VST as screening test for OD in patients admitted to geriatric or medical wards was substantial with an overall Kappa value of 0.77 (95% CI 0.65-0.89) however interrater reliability varied among hospitals ranging from 0.37 (95% CI -0.01 to 0.41) to 0.85 (95% CI 0.75-1.00). Interrater reliability of the accompanying recommendations of volume and viscosity was moderate with a weighted kappa value of 0.55 (95% CI 0.37-0.73) for viscosity and 0.53 (95% CI 0.36-0.7) for volume. The overall prevalence of OD was 34.5%, ranging from 8% to 53.6% across hospitals. The prevalence and bias

  19. C-130: Results of center wing residual strength and crack propagation test program

    Science.gov (United States)

    Reeder, F. L.; Dirkin, W. J.; Snider, H. L.

    1971-01-01

    Fourteen C-130 airplane center wings which had experienced from approximately 4,000 to 13,000 hours of flight service and its associated fatigue damage were tested to destruction, seven in upbending and seven in downbending. Six wings were tested directly for static residual strength in the fatigue-damaged condition as received from field service. The other eight wings were tested in crack propagation cyclic testing at a prescribed stress level for a maximum of 10,000 cycles. Then the stress level was reduced and testing was continued up to a maximum of 20,000 total cycles. Cyclic testing was performed with constant-amplitude stresses at a stress ratio of +0.1. Maximum cyclic skin stresses were approximately 18,000 psi. At the conclusion of cyclic testing, a static test to destruction was conducted to determine the residual strength of each fatigue-damaged specimen.

  20. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP: VOLUME 69 RBRC SCIENTIFIC REVIEW COMMITTEE MEETING

    International Nuclear Information System (INIS)

    SAMIOS, N.P.

    2005-01-01

    The RIKEN BNL Research Center (RSRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the 'Rikagaku Kenkyusho' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists, A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are sixty nine proceedings volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  1. Satisfactory rate of post-processing visualization of fetal cerebral axial, sagittal, and coronal planes from three-dimensional volumes acquired in routine second trimester ultrasound practice by sonographers of peripheral centers.

    Science.gov (United States)

    Rizzo, Giuseppe; Pietrolucci, Maria Elena; Capece, Giuseppe; Cimmino, Ernesto; Colosi, Enrico; Ferrentino, Salvatore; Sica, Carmine; Di Meglio, Aniello; Arduini, Domenico

    2011-08-01

    The aim of this study was to evaluate the feasibility to visualize central nervous system (CNS) diagnostic planes from three-dimensional (3D) brain volumes obtained in ultrasound facilities with no specific experience in fetal neurosonography. Five sonographers prospectively recorded transabdominal 3D CNS volumes starting from an axial approach on 500 consecutive pregnancies at 19-24 weeks of gestation undergoing routine ultrasound examination. Volumes were sent to the referral center (Department of Obstetrics and Gynecology, Università Roma Tor Vergata, Italy) and two independent reviewers with experience in 3D ultrasound assessed their quality in the display of axial, coronal, and sagittal planes. CNS volumes were acquired in 491/500 pregnancies (98.2%). The two reviewers acknowledged the presence of satisfactory images with a visualization rate ranging respectively between 95.1% and 97.14% for axial planes, 73.72% and 87.16% for coronal planes, and 78.41% and 94.29% for sagittal planes. The agreement rate between the two reviewers as expressed by Cohen's kappa coefficient was >0.87 for axial planes, >0.89 for coronal planes, and >0.94 for sagittal planes. The presence of a maternal body mass index >30 alters the probability of achieving satisfactory CNS views, while existence of previous maternal lower abdomen surgery does not affect the quality of the reconstructed planes. CNS volumes acquired by 3D ultrasonography in peripheral centers showed a quality high enough to allow a detailed fetal neurosonogram.

  2. Small Radioisotope Power System Testing at NASA Glenn Research Center

    Science.gov (United States)

    Dugala, Gina; Bell, Mark; Oriti, Salvatore; Fraeman, Martin; Frankford, David; Duven, Dennis

    2013-01-01

    In April 2009, NASA Glenn Research Center (GRC) formed an integrated product team (IPT) to develop a Small Radioisotope Power System (SRPS) utilizing a single Advanced Stirling Convertor (ASC) with passive balancer. A single ASC produces approximately 80 We making this system advantageous for small distributed lunar science stations. The IPT consists of Sunpower, Inc., to provide the single ASC with a passive balancer, The Johns Hopkins University Applied Physics Laboratory (JHUAPL) to design an engineering model Single Convertor Controller (SCC) for an ASC with a passive balancer, and NASA GRC to provide technical support to these tasks and to develop a simulated lunar lander test stand. The single ASC with a passive balancer, simulated lunar lander test stand, and SCC were delivered to GRC and were tested as a system. The testing sequence at GRC included SCC fault tolerance, integration, electromagnetic interference (EMI), vibration, and extended operation testing. The SCC fault tolerance test characterized the SCCs ability to handle various fault conditions, including high or low bus power consumption, total open load or short circuit, and replacing a failed SCC card while the backup maintains control of the ASC. The integrated test characterized the behavior of the system across a range of operating conditions, including variations in cold-end temperature and piston amplitude, including the emitted vibration to both the sensors on the lunar lander and the lunar surface. The EMI test characterized the AC and DC magnetic and electric fields emitted by the SCC and single ASC. The vibration test confirms the SCCs ability to control the single ASC during launch. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the ASC with a passive balancer and the SCC. This paper will discuss the results of each of these tests.

  3. Volume reduction through incineration of low-activity radioactive wastes

    International Nuclear Information System (INIS)

    Eymeri, J.; Gauthey, J.C.; Chaise, D.; Lafite, G.

    1993-01-01

    The aim of the waste treatment plant, designed by Technicatome (CEA) for an Indonesian Nuclear Research Center, is to reduce through incineration the volume of low-activity radioactive wastes such as technological solids (cotton, PVC, paper board), biological solids (animal bones) and liquids (cutting fluids...). The complete combustion is realized with a total air multi-fuel burner (liquid wastes) and flash pyrolysis-complete combustion (solid wastes). A two stage flue gas filtration system, a flue gas washing system, and an ash recovery system are used. A test platform has been built. 3 figs

  4. Macular thickness and volume in the elderly

    DEFF Research Database (Denmark)

    Subhi, Yousif; Forshaw, Thomas; Sørensen, Torben Lykke

    2016-01-01

    manifests in the macula of the elderly focusing on clinical relevant measures that are thicknesses and volumes of different macular areas. Ageing seems to increase center point foveal thickness. Ageing does not seem to change the center subfield thickness significantly. Ageing decreases the inner and outer...

  5. Increases in Recent HIV Testing Among Men Who Have Sex With Men Coincide With the Centers for Disease Control and Prevention's Expanded Testing Initiative

    Science.gov (United States)

    Cooley, Laura A.; Wejnert, Cyprian; Rose, Charles E.; Paz-Bailey, Gabriela; Taussig, Jennifer; Gern, Robert; Hoyte, Tamika; Salazar, Laura; White, Jianglan; Todd, Jeff; Bautista, Greg; Flynn, Colin; Sifakis, Frangiscos; German, Danielle; Isenberg, Debbie; Driscoll, Maura; Hurwitz, Elizabeth; Doherty, Rose; Wittke, Chris; Prachand, Nikhil; Benbow, Nanette; Melville, Sharon; Pannala, Praveen; Yeager, Richard; Sayegh, Aaron; Dyer, Jim; Sheu, Shane; Novoa, Alicia; Thrun, Mark; Al-Tayyib, Alia; Wilmoth, Ralph; Higgins, Emily; Griffin, Vivian; Mokotoff, Eve; MacMaster, Karen; Wolverton, Marcia; Risser, Jan; Rehman, Hafeez; Padgett, Paige; Bingham, Trista; Sey, Ekow Kwa; LaLota, Marlene; Metsch, Lisa; Forrest, David; Beck, Dano; Cardenas, Gabriel; Nemeth, Chris; Anderson, Bridget J.; Watson, Carol-Ann; Smith, Lou; Robinson, William T.; Gruber, DeAnn; Barak, Narquis; Murrill, Chris; Neaigus, Alan; Jenness, Samuel; Hagan, Holly; Reilly, Kathleen H.; Wendel, Travis; Cross, Helene; Bolden, Barbara; D'Errico, Sally; Wogayehu, Afework; Godette, Henry; Brady, Kathleen A.; Kirkland, Althea; Sifferman, Andrea; Miguelino-Keasling, Vanessa; Velasco, Al; Tovar, Veronica; Raymond, H. Fisher; De León, Sandra Miranda; Rolón-Colón, Yadira; Marzan, Melissa; Courogen, Maria; Jaenicke, Tom; Thiede, Hanne; Burt, Richard; Jia, Yujiang; Opoku, Jenevieve; Sansone, Marie; West, Tiffany; Magnus, Manya; Kuo, Irene

    2015-01-01

    According to National HIV Behavioral Surveillance system data, human immunodeficiency virus (HIV) testing increased among gay, bisexual, and other men who have sex with men from 2008 to 2011 in cities funded by the Centers for Disease Control and Prevention's Expanded Testing Initiative, suggesting that focused HIV testing initiatives might have positive effects. PMID:25352589

  6. 77 FR 28281 - Withdrawal of Revocation of TSCA Section 4 Testing Requirements for One High Production Volume...

    Science.gov (United States)

    2012-05-14

    ... Withdrawal of Revocation of TSCA Section 4 Testing Requirements for One High Production Volume Chemical...]amino]- (CAS No. 1324-76-1), also known as C.I. Pigment Blue 61. EPA received an adverse comment regarding C.I. Pigment Blue 61. This document withdraws the revocation of testing requirements for C.I...

  7. Demonstration, testing, & evaluation of in situ heating of soil. Draft final report, Volume I

    Energy Technology Data Exchange (ETDEWEB)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-02-12

    This document is a draft final report (Volume 1) for US DOE contract entitled, {open_quotes}Demonstration Testing and Evaluation of In Situ Soil Heating,{close_quotes} Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report and Volume II contains appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120{degrees} to 130{degrees}C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow.

  8. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP, VOLUME 65, RHIC SPIN COLLABORATION MEETINGS XXVII, XXVIII, and XXX

    International Nuclear Information System (INIS)

    OGAWA, A.

    2004-01-01

    The RIKEN BNL Research Center (RSRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the 'Rikagaku Kenkyusho' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD, and RHIC physics through the nurturing of a new generation of young physicists. The RBRC has both a theory and experimental component. At present the theoretical group has 4 Fellows and 3 Research Associates as well as 11 RHIC Physics/University Fellows (academic year 2003-2004). To date there are approximately 30 graduates from the program of which 13 have attained tenure positions at major institutions worldwide. The experimental group is smaller and has 2 Fellows and 3 RHIC Physics/University Fellows and 3 Research Associates, and historically 6 individuals have attained permanent positions. Beginning in 2001 a new RIKEN Spin Program (RSP) category was implemented at RBRC. These appointments are joint positions of RBRC and RIKEN and include the following positions in theory and experiment: RSP Researchers, RSP Research Associates, and Young Researchers, who are mentored by senior RBRC Scientists, A number of RIKEN Jr. Research Associates and Visiting Scientists also contribute to the physics program at the Center. RBRC has an active workshop program on strong interaction physics with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are sixty nine proceedings volumes available. The construction of a 0.6 teraflops parallel processor, dedicated to lattice QCD, begun at the Center on February 19, 1998, was completed on August 28, 1998 and is still

  9. Treatment of discharge water from hydrostatic testing of natural gas pipelines. Volume 4. Topical report, January 1989-June 1992

    International Nuclear Information System (INIS)

    Tallon, J.T.; Lee-Ryan, P.B.; Volpi, K.A.; Fillo, J.P.

    1992-06-01

    The report presents results developed from bench- and full-scale treatment testing conducted on discharge water from hydrostatic testing of natural gas pipelines. Bench-scale testing examined sedimentation with and without chemical coagulants for reducing iron and total suspended solids, aeration for removal of volatile organics, and activated carbon adsorption for removal of organic constituents. Treatment results are provided for a full-scale treatment process, which utilized a hay bale structure and adsorbent booms for removing suspended solids and oil from the discharge water. Detailed characterization results are presented for test water collected before and after treatment. Results developed from an economic analysis of other potential treatment/disposal alternatives are also presented. A total of eight approaches that may be applied for managing constituents present in hydrostatic test waters are examined. The report is Volume 4 of a five-volume report series

  10. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    Science.gov (United States)

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require

  11. PROCEEDINGS OF RIKEN BNL RESEARCH CENTER WORKSHOP ENTITLED: ''PARTON ORBITAL ANGULAR MOMENTUM'' VOLUME 81

    International Nuclear Information System (INIS)

    Bunce, G.; Fields, D.; Vogelsang, W.

    2006-01-01

    The joint UNM/RBRC 'Workshop on Parton Orbital Angular Momentum' was held on February 24th through 26th at the University of New Mexico Department of Physics and Astronomy in Albuquerque, New Mexico, and was sponsored by The University of New Mexico (Physics Department, New Mexico Center for Particle Physics, Dean of Arts and Sciences, and Office of the Vice Provost for Research and Economic Development) and the NUN-BNL Research Center. The workshop was motivated by recent and upcoming experimental data based on methods which have been proposed to access partonic angular momenta, including Deeply Virtual Compton Scattering, measuring the Sivers functions, and measuring helicity dependent k t in jets. Our desire was to clarify the state of the art in the theoretical understanding in this area, and to help define what might be learned about partonic orbital angular momenta Erom present and upcoming high precision data, particularly at RHIC, Jlab, COMPASS and HERMES. The workshop filled two rather full days of talks fiom both theorists and experimentalists, with a good deal of discussion during, and in between talks focusing on the relationship between the intrinsic transverse momentum, orbital angular momentum, and observables such as the Sivers Function. These talks and discussions were particularly illuminating and the organizers wish to express their sincere thanks to everyone for contributing to this workshop. Each workshop speaker is encouraged to select a few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. To date there are eighty proceeding volumes available

  12. Self-Access Centers: Maximizing Learners’ Access to Center Resources

    Directory of Open Access Journals (Sweden)

    Mark W. Tanner

    2010-09-01

    Full Text Available Originally published in TESL-EJ March 2009, Volume 12, Number 4 (http://tesl-ej.org/ej48/a2.html. Reprinted with permission from the authors.Although some students have discovered how to use self-access centers effectively, the majority appear to be unaware of available resources. A website and database of materials were created to help students locate materials and use the Self-Access Study Center (SASC at Brigham Young University’s English Language Center (ELC more effectively. Students took two surveys regarding their use of the SASC. The first survey was given before the website and database were made available. A second survey was administered 12 weeks after students had been introduced to the resource. An analysis of the data shows that students tend to use SASC resources more autonomously as a result of having a web-based database. The survey results suggest that SAC managers can encourage more autonomous use of center materials by provided a website and database to help students find appropriate materials to use to learn English.

  13. The Lathrop Wells volcanic center

    International Nuclear Information System (INIS)

    Crowe, B.; Morley, R.

    1992-01-01

    The Lathrop Wells volcanic center is located 20 km south of the potential Yucca Mountain site, at the south end of the Yucca Mountain range. This paper discusses a detailed Study Plan which was prepared describing planned geochronology and field studies to assess the chronology of the Lathrop Wells volcanic center and other Quaternary volcanic centers in the region. A paper was published discussing the geomorphic and soil evidence for a late Pleistocene or Holoceno age for the main cone of the center. The purpose of this paper was to expose the ideas concerning the age of the Lathrop Wells center to scientific scrutiny. Additionally, field evidence was described suggesting the Lathrop Wells center may have formed from multiple eruptive events with significant intervals of no activity between events. This interpretation breaks with established convention in the volcanological literature that small volume basalt centers are monogenetic

  14. 1999 Annual meeting on non-destructive testing. 10. Anniversary of DGZfP in Germany. Volumes 1 and 2. Proceedings

    International Nuclear Information System (INIS)

    1999-01-01

    The two proceedings volumes contain the 92 papers presented at the meeting, dealing with the following key subjects: Ultrasonic testing; industrial radiography and other testing methods using radiation; acoustic emission testing; materials charcaterization; training and certification; standards and other technical codes and regulations. (orig./CB) [de

  15. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.

    Science.gov (United States)

    Pfützner, Andreas; Schipper, Christina; Ramljak, Sanja; Flacke, Frank; Sieber, Jochen; Forst, Thomas; Musholt, Petra B

    2013-11-01

    Accuracy of blood glucose readings is (among other things) dependent on the test strip being completely filled with sufficient sample volume. The devices are supposed to display an error message in case of incomplete filling. This laboratory study was performed to test the performance of 31 commercially available devices in case of incomplete strip filling. Samples with two different glucose levels (60-90 and 300-350 mg/dl) were used to generate three different sample volumes: 0.20 µl (too low volume for any device), 0.32 µl (borderline volume), and 1.20 µl (low but supposedly sufficient volume for all devices). After a point-of-care capillary reference measurement (StatStrip, NovaBiomedical), the meter strip was filled (6x) with the respective volume, and the response of the meters (two devices) was documented (72 determinations/meter type). Correct response was defined as either an error message indicating incomplete filling or a correct reading (±20% compared with reference reading). Only five meters showed 100% correct responses [BGStar and iBGStar (both Sanofi), ACCU-CHEK Compact+ and ACCU-CHEK Mobile (both Roche Diagnostics), OneTouch Verio (LifeScan)]. The majority of the meters (17) had up to 10% incorrect reactions [predominantly incorrect readings with sufficient volume; Precision Xceed and Xtra, FreeStyle Lite, and Freedom Lite (all Abbott); GlucoCard+ and GlucoMen GM (both Menarini); Contour, Contour USB, and Breeze2 (all Bayer); OneTouch Ultra Easy, Ultra 2, and Ultra Smart (all LifeScan); Wellion Dialog and Premium (both MedTrust); FineTouch (Terumo); ACCU-CHEK Aviva (Roche); and GlucoTalk (Axis-Shield)]. Ten percent to 20% incorrect reactions were seen with OneTouch Vita (LifeScan), ACCU-CHEK Aviva Nano (Roche), OmniTest+ (BBraun), and AlphaChek+ (Berger Med). More than 20% incorrect reactions were obtained with Pura (Ypsomed), GlucoCard Meter and GlucoMen LX (both Menarini), Elite (Bayer), and MediTouch (Medisana). In summary, partial and

  16. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    Science.gov (United States)

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; pcorrelation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  17. Evaluate Data Center Network Performance

    DEFF Research Database (Denmark)

    Pilimon, Artur

    through a data center network, which is usually built with layer 2 switches and layer 3 routers. The topology of the data center network is crucial for latency in the data communication to and from the data center and between servers in the data center. Tests can be conducted to measure latency and other...... Engineering, scientists evaluate data center network topologies with an SDN-based (Software-Defined Networking) control framework measuring network performance – primarily latency. This can be used to plan data center scaling by testing how a new topology will function before changes are made. Data center...... performance parameters for different data center network topologies. It is however important that tests can be repeated and reproduced to have comparable information from the tests. There are, of course, many topologies that can be used for data center networks. At DTU Fotonik, Department of Photonics...

  18. Usability Testing, User-Centered Design, and LibGuides Subject Guides: A Case Study

    Science.gov (United States)

    Sonsteby, Alec; DeJonghe, Jennifer

    2013-01-01

    Usability testing has become a routine way for many libraries to ensure that their Web presence is user-friendly and accessible. At the same time, popular subject guide creation systems, such as LibGuides, decentralize Web content creation and put authorship into the hands of librarians who may not be trained in user-centered design principles. At…

  19. Space Environment Testing of Photovoltaic Array Systems at NASA's Marshall Space Flight Center

    Science.gov (United States)

    Phillips, Brandon S.; Schneider, Todd A.; Vaughn, Jason A.; Wright, Kenneth H., Jr.

    2015-01-01

    To successfully operate a photovoltaic (PV) array system in space requires planning and testing to account for the effects of the space environment. It is critical to understand space environment interactions not only on the PV components, but also the array substrate materials, wiring harnesses, connectors, and protection circuitry (e.g. blocking diodes). Key elements of the space environment which must be accounted for in a PV system design include: Solar Photon Radiation, Charged Particle Radiation, Plasma, and Thermal Cycling. While solar photon radiation is central to generating power in PV systems, the complete spectrum includes short wavelength ultraviolet components, which photo-ionize materials, as well as long wavelength infrared which heat materials. High energy electron radiation has been demonstrated to significantly reduce the output power of III-V type PV cells; and proton radiation damages material surfaces - often impacting coverglasses and antireflective coatings. Plasma environments influence electrostatic charging of PV array materials, and must be understood to ensure that long duration arcs do not form and potentially destroy PV cells. Thermal cycling impacts all components on a PV array by inducing stresses due to thermal expansion and contraction. Given such demanding environments, and the complexity of structures and materials that form a PV array system, mission success can only be ensured through realistic testing in the laboratory. NASA's Marshall Space Flight Center has developed a broad space environment test capability to allow PV array designers and manufacturers to verify their system's integrity and avoid costly on-orbit failures. The Marshall Space Flight Center test capabilities are available to government, commercial, and university customers. Test solutions are tailored to meet the customer's needs, and can include performance assessments, such as flash testing in the case of PV cells.

  20. Development of the Nordic Bioeconomy: NCM reporting: Test centers for green energy solutions - Biorefineries and business needs

    DEFF Research Database (Denmark)

    Lange, Lene; Björnsdóttir, Bryndís; Brandt, Asbjørn

    In 2014 the Nordic Council of Ministers initiated a new bioeconomy project: “Test centers for green energy solutions – Biorefineries and Busi-ness needs”. The purpose was to strengthen green growth in the area of the bioeconomy by analyzing and mapping the current status of the bio-economy in the......In 2014 the Nordic Council of Ministers initiated a new bioeconomy project: “Test centers for green energy solutions – Biorefineries and Busi-ness needs”. The purpose was to strengthen green growth in the area of the bioeconomy by analyzing and mapping the current status of the bio...

  1. Tried & Tested. Ideas from Teacher Centers in the Southeast.

    Science.gov (United States)

    Bohstedt, Jinx, Ed.; Eisenmann-Donahue, Pat, Ed.

    Throughout the southeastern United States, teacher centers share much in common. The conceptual framework of teachers helping teachers inspires the development of resources and services which are similar whether the center serves a large district or only a few schools. Although the teacher centers share similar philosophies, concerns, successes,…

  2. An Evaluation of North Korea’s Nuclear Test by Belbasi Nuclear Tests Monitoring Center-KOERI

    Science.gov (United States)

    Necmioglu, O.; Meral Ozel, N.; Semin, K.

    2009-12-01

    Bogazici University and Kandilli Observatory and Earthquake Research Institute (KOERI) is acting as the Turkish National Data Center (NDC) and responsible for the operation of the International Monitoring System (IMS) Primary Seismic Station (PS-43) under Belbasi Nuclear Tests Monitoring Center for the verification of compliance with the Comprehensive Nuclear-Test-Ban Treaty (CTBT) since February 2000. The NDC is responsible for operating two arrays which are part of the IMS, as well as for transmitting data from these stations to the International Data Centre (IDC) in Vienna. The Belbasi array was established in 1951, as a four-element (Benioff 1051) seismic array as part of the United States Atomic Energy Detection System (USAEDS). Turkish General Staff (TGS) and U.S. Air Force Technical Application Center (AFTAC) under the Defense and Economic Cooperation Agreement (DECA) jointly operated this short period array. The station was upgraded and several seismometers were added to array during 1951 and 1994 and the station code was changed from BSRS (Belbasi Seismic Research Station) to BRTR-PS43 later on. PS-43 is composed of two sub-arrays (Ankara and Keskin): the medium-period array with a ~40 km radius located in Ankara and the short-period array with a ~3 km radius located in Keskin. Each array has a broadband element located at the middle of the circular geometry. Short period instruments are installed at depth 30 meters from the surface while medium and broadband instruments are installed at depth 60 meters from surface. On 25 May 2009, The Democratic People’s Republic of Korea (DPRK) claimed that it had conducted a nuclear test. Corresponding seismic event was recorded by IMS and IDC released first automatic estimation of time (00:54:43 GMT), location (41.2896°N and 129.0480°E) and the magnitude (4.52 mb) of the event in less than two hours time (USGS: 00:54:43 GMT; 41.306°N, 129.029°E; 4.7 mb) During our preliminary analysis of the 25th May 2009 DPRK

  3. Space Station Environmental Control and Life Support System Test Facility at Marshall Space Flight Center

    Science.gov (United States)

    Springer, Darlene

    1989-01-01

    Different aspects of Space Station Environmental Control and Life Support System (ECLSS) testing are currently taking place at Marshall Space Flight Center (MSFC). Unique to this testing is the variety of test areas and the fact that all are located in one building. The north high bay of building 4755, the Core Module Integration Facility (CMIF), contains the following test areas: the Subsystem Test Area, the Comparative Test Area, the Process Material Management System (PMMS), the Core Module Simulator (CMS), the End-use Equipment Facility (EEF), and the Pre-development Operational System Test (POST) Area. This paper addresses the facility that supports these test areas and briefly describes the testing in each area. Future plans for the building and Space Station module configurations will also be discussed.

  4. Bibliography, subject index, and author index of the literature examined by the radiation shielding information center. Volume 6. Reactor and weapons radiation shielding

    International Nuclear Information System (INIS)

    1980-05-01

    An indexed bibliography is presented of literature selected by the Radiation Shielding Information Center since the previous volume was published in 1978 in the area of radiation transport and shielding against radiation from nuclear reactors, x-ray machines, radioisotopes, nuclear weapons (including fallout), and low energy accelerators (e.g., neutron generators). The bibliography was typeset from data processed by computer from magnetic tape files. In addition to lists of literature titles by subject categories (accessions 4951-6200), an author index is given

  5. Automotive Manufacturing Assessment System : Volume 1. Master Product Schedules.

    Science.gov (United States)

    1999-11-01

    Volume I is part of a four volume set documenting areas of research resulting from the development of the Automotive Manufacturing Assessment System (AMAS) for the DOT/Transportation Systems Center. AMAS was designed to assist in the evaluation of in...

  6. Preliminary thermal and thermomechanical modeling for the near surface test facility heater experiments at Hanford. Volume II: Appendix D

    International Nuclear Information System (INIS)

    Chan, T.; Remer, J.S.

    1978-12-01

    Appendix D is a complete set of figures illustrating the detailed calculations necessary for designing the heater experiments at the Near Surface Test Facility (NSTF) at Hanford, Washington. The discussion of the thermal and thermomechanical modeling that yielded these calculations is presented in Volume 1. A summary of the figures and the models they illustrate is given in table D1. The most important figures have also been included in the discussion in Volume 1, and Table D2 lists the figure numbers in this volume that correspond to figure numbers used there

  7. Test Program for Stirling Radioisotope Generator Hardware at NASA Glenn Research Center

    Science.gov (United States)

    Lewandowski, Edward J.; Bolotin, Gary S.; Oriti, Salvatore M.

    2015-01-01

    Stirling-based energy conversion technology has demonstrated the potential of high efficiency and low mass power systems for future space missions. This capability is beneficial, if not essential, to making certain deep space missions possible. Significant progress was made developing the Advanced Stirling Radioisotope Generator (ASRG), a 140-W radioisotope power system. A variety of flight-like hardware, including Stirling convertors, controllers, and housings, was designed and built under the ASRG flight development project. To support future Stirling-based power system development NASA has proposals that, if funded, will allow this hardware to go on test at the NASA Glenn Research Center. While future flight hardware may not be identical to the hardware developed under the ASRG flight development project, many components will likely be similar, and system architectures may have heritage to ASRG. Thus, the importance of testing the ASRG hardware to the development of future Stirling-based power systems cannot be understated. This proposed testing will include performance testing, extended operation to establish an extensive reliability database, and characterization testing to quantify subsystem and system performance and better understand system interfaces. This paper details this proposed test program for Stirling radioisotope generator hardware at NASA Glenn. It explains the rationale behind the proposed tests and how these tests will meet the stated objectives.

  8. Aircraft Engine Noise Research and Testing at the NASA Glenn Research Center

    Science.gov (United States)

    Elliott, Dave

    2015-01-01

    The presentation will begin with a brief introduction to the NASA Glenn Research Center as well as an overview of how aircraft engine noise research fits within the organization. Some of the NASA programs and projects with noise content will be covered along with the associated goals of aircraft noise reduction. Topics covered within the noise research being presented will include noise prediction versus experimental results, along with engine fan, jet, and core noise. Details of the acoustic research conducted at NASA Glenn will include the test facilities available, recent test hardware, and data acquisition and analysis methods. Lastly some of the actual noise reduction methods investigated along with their results will be shown.

  9. Maintenance Personnel Performance Simulation (MAPPS) model: description of model content, structure, and sensitivity testing. Volume 2

    International Nuclear Information System (INIS)

    Siegel, A.I.; Bartter, W.D.; Wolf, J.J.; Knee, H.E.

    1984-12-01

    This volume of NUREG/CR-3626 presents details of the content, structure, and sensitivity testing of the Maintenance Personnel Performance Simulation (MAPPS) model that was described in summary in volume one of this report. The MAPPS model is a generalized stochastic computer simulation model developed to simulate the performance of maintenance personnel in nuclear power plants. The MAPPS model considers workplace, maintenance technician, motivation, human factors, and task oriented variables to yield predictive information about the effects of these variables on successful maintenance task performance. All major model variables are discussed in detail and their implementation and interactive effects are outlined. The model was examined for disqualifying defects from a number of viewpoints, including sensitivity testing. This examination led to the identification of some minor recalibration efforts which were carried out. These positive results indicate that MAPPS is ready for initial and controlled applications which are in conformity with its purposes

  10. Space Environmental Effects Testing Capability at the Marshall Space Flight Center

    Science.gov (United States)

    DeWittBurns, H.; Craven, Paul; Finckenor, Miria; Nehls, Mary; Schneider, Todd; Vaughn, Jason

    2012-01-01

    Understanding the effects of the space environment on materials and systems is fundamental and essential for mission success. If not properly understood and designed for, the effects of the environment can lead to degradation of materials, reduction of functional lifetime, and system failure. In response to this need, the Marshall Space Flight Center has developed world class Space Environmental Effects (SEE) expertise and test facilities to simulate the space environment. Capabilities include multiple unique test systems comprising the most complete SEE testing capability available. These test capabilities include charged particle radiation (electrons, protons, ions), ultraviolet radiation (UV), vacuum ultraviolet radiation (VUV), atomic oxygen, plasma effects, space craft charging, lunar surface and planetary effects, vacuum effects, and hypervelocity impacts as well as the combination of these capabilities. In addition to the uniqueness of the individual test capabilities, MSFC is the only NASA facility where the effects of the different space environments can be tested in one location. Combined with additional analytical capabilities for pre- and post-test evaluation, MSFC is a one-stop shop for materials testing and analysis. The SEE testing and analysis are performed by a team of award winning experts nationally recognized for their contributions in the study of the effects of the space environment on materials and systems. With this broad expertise in space environmental effects and the variety of test systems and equipment available, MSFC is able to customize tests with a demonstrated ability to rapidly adapt and reconfigure systems to meet customers needs. Extensive flight experiment experience bolsters this simulation and analysis capability with a comprehensive understanding of space environmental effects.

  11. Social influence in child care centers: a test of the theory of normative social behavior.

    Science.gov (United States)

    Lapinski, Maria Knight; Anderson, Jenn; Shugart, Alicia; Todd, Ewen

    2014-01-01

    Child care centers are a unique context for studying communication about the social and personal expectations about health behaviors. The theory of normative social behavior (TNSB; Rimal & Real, 2005 ) provides a framework for testing the role of social and psychological influences on handwashing behaviors among child care workers. A cross-sectional survey of child care workers in 21 centers indicates that outcome expectations and group identity increase the strength of the relationship between descriptive norms and handwashing behavior. Injunctive norms also moderate the effect of descriptive norms on handwashing behavior such that when strong injunctive norms are reported, descriptive norms are positively related to handwashing, but when weak injunctive norms are reported, descriptive norms are negatively related to handwashing. The findings suggest that communication interventions in child care centers can focus on strengthening injunctive norms in order to increase handwashing behaviors in child care centers. The findings also suggest that the theory of normative social behavior can be useful in organizational contexts.

  12. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  13. Test of Hydrogen-Oxygen PEM Fuel Cell Stack at NASA Glenn Research Center

    Science.gov (United States)

    Bents, David J.; Scullin, Vincent J.; Chang, Bei-Jiann; Johnson, Donald W.; Garcia, Christopher P.; Jakupca, Ian J.

    2003-01-01

    This paper describes performance characterization tests of a 64 cell hydrogen oxygen PEM fuel cell stack at NASA Glenn Research Center in February 2003. The tests were part of NASA's ongoing effort to develop a regenerative fuel cell for aerospace energy storage applications. The purpose of the tests was to verify capability of this stack to operate within a regenerative fuel cell, and to compare performance with earlier test results recorded by the stack developer. Test results obtained include polarization performance of the stack at 50 and 100 psig system pressure, and a steady state endurance run at 100 psig. A maximum power output of 4.8 kWe was observed during polarization runs, and the stack sustained a steady power output of 4.0 kWe during the endurance run. The performance data obtained from these tests compare reasonably close to the stack developer's results although some additional spread between best to worst performing cell voltages was observed. Throughout the tests, the stack demonstrated the consistent performance and repeatable behavior required for regenerative fuel cell operation.

  14. The Impact of Hospital Closures and Hospital and Population Characteristics on Increasing Emergency Department Volume: A Geographic Analysis.

    Science.gov (United States)

    Lee, David C; Carr, Brendan G; Smith, Tony E; Tran, Van C; Polsky, Daniel; Branas, Charles C

    2015-12-01

    Emergency visits are rising nationally, whereas the number of emergency departments is shrinking. However, volume has not increased uniformly at all emergency departments. It is unclear what factors account for this variability in emergency volume growth rates. The objective of this study was to test the association of hospital and population characteristics and the effect of hospital closures with increases in emergency department volume. The study team analyzed emergency department volume at New York State hospitals from 2004 to 2010 using data from cost reports and administrative databases. Multivariate regression was used to evaluate characteristics associated with emergency volume growth. Spatial analytics and distances between hospitals were used in calculating the predicted impact of hospital closures on emergency department use. Among the 192 New York hospitals open from 2004 to 2010, the mean annual increase in emergency department visits was 2.7%, but the range was wide (-5.5% to 11.3%). Emergency volume increased nearly twice as fast at tertiary referral centers (4.8%) and nonurban hospitals (3.7% versus urban at 2.1%) after adjusting for other characteristics. The effect of hospital closures also strongly predicted variation in growth. Emergency volume is increasing faster at specific hospitals: tertiary referral centers, nonurban hospitals, and those near hospital closures. This study provides an understanding of how emergency volume varies among hospitals and predicts the effect of hospital closures in a statewide region. Understanding the impact of these factors on emergency department use is essential to ensure that these populations have access to critical emergency services.

  15. Demonstration, testing, ampersand evaluation of in situ heating of soil. Draft final report, Volume I

    International Nuclear Information System (INIS)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-01-01

    This document is a draft final report (Volume 1) for US DOE contract entitled, open-quotes Demonstration Testing and Evaluation of In Situ Soil Heating,close quotes Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report and Volume II contains appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120 degrees to 130 degrees C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow

  16. Air-deployable oil spill sampling devices review phase 2 testing. Volume 1

    International Nuclear Information System (INIS)

    Hawke, L.; Dumouchel, A.; Fingas, M.; Brown, C.E.

    2007-01-01

    SAIC Canada tested air deployable oil sampling devices for the Emergencies Science and Technology Division of Environment Canada in order to determine the applicability and status of these devices. The 3 devices tested were: Canada's SABER (sampling autonomous buoy for evidence recovery), the United States' POPEIE (probe for oil pollution evidence in the environment); and, Sweden's SAR Floatation 2000. They were tested for buoyancy properties, drift behaviour and sampler sorbent pickup ratios. The SAR and SABER both had lesser draft and greater freeboard, while the POPEIE had much greater draft than freeboard. All 3 devices could be used for oil sample collection in that their drift characteristics would allow for the SABER and SAR devices to be placed upwind of the slick while the POPEIE device could be placed downwind of an oil spill. The sorbent testing revealed that Sefar sorbent and Spectra sorbent used in the 3 devices had negative pickup ratios for diesel but performance improved as oil viscosity increased. Both sorbents are inert and capable of collecting oil in sufficient volumes for consistent fingerprinting analysis. 10 refs., 8 tabs., 8 figs

  17. Air STAR Beyond Visual Range UAS Description and Preliminary Test Results

    Science.gov (United States)

    Cunningham, Kevin; Cox, David E.; Foster, John V.; Riddick, Stephen E.; Laughter, Sean A.

    2016-01-01

    The NASA Airborne Subscale Transport Aircraft Research Unmanned Aerial System project's capabilities were expanded by updating the system design and concept of operations. The new remotely piloted airplane system design was flight tested to assess integrity and operational readiness of the design to perform flight research. The purpose of the system design is to improve aviation safety by providing a capability to validate, in high-risk conditions, technologies to prevent airplane loss of control. Two principal design requirements were to provide a high degree of reliability and that the new design provide a significant increase in test volume (relative to operations using the previous design). The motivation for increased test volume is to improve test efficiency and allow new test capabilities that were not possible with the previous design and concept of operations. Three successful test flights were conducted from runway 4-22 at NASA Goddard Space Flight Center's Wallops Flight Facility.

  18. Interventions to Increase Male Attendance and Testing for Sexually Transmitted Infections at Publicly-Funded Family Planning Clinics.

    Science.gov (United States)

    Fine, David; Warner, Lee; Salomon, Sarah; Johnson, David M

    2017-07-01

    We assessed the impact of staff, clinic, and community interventions on male and female family planning client visit volume and sexually transmitted infection testing at a multisite community-based health care agency. Staff training, clinic environmental changes, in-reach/outreach, and efficiency assessments were implemented in two Family Health Center (San Diego, CA) family planning clinics during 2010-2012; five Family Health Center family planning programs were identified as comparison clinics. Client visit records were compared between preintervention (2007-2009) and postintervention (2010-2012) for both sets of clinics. Of 7,826 male client visits during the time before intervention, most were for clients who were aged male visits (4,004 to 8,385; Δ = +109%); for comparison clinics, male visits increased modestly (3,822 to 4,500; Δ = +18%). The proportion of male clinic visits where chlamydia testing was performed increased in intervention clinics (35% to 42%; p males yielded similar findings for male client volume and chlamydia testing. The number of female visits declined nearly 40% in both comparison (21,800 to 13,202; -39%) and intervention clinics (30,830 to 19,971; -35%) between preintervention and postintervention periods. Multilevel interventions designed to increase male client volume and sexually transmitted infection testing services in family planning clinics succeeded without affecting female client volume or services. Copyright © 2017 Society for Adolescent Health and Medicine. All rights reserved.

  19. Future aerospace ground test facility requirements for the Arnold Engineering Development Center

    Science.gov (United States)

    Kirchner, Mark E.; Baron, Judson R.; Bogdonoff, Seymour M.; Carter, Donald I.; Couch, Lana M.; Fanning, Arthur E.; Heiser, William H.; Koff, Bernard L.; Melnik, Robert E.; Mercer, Stephen C.

    1992-01-01

    Arnold Engineering Development Center (AEDC) was conceived at the close of World War II, when major new developments in flight technology were presaged by new aerodynamic and propulsion concepts. During the past 40 years, AEDC has played a significant part in the development of many aerospace systems. The original plans were extended through the years by some additional facilities, particularly in the area of propulsion testing. AEDC now has undertaken development of a master plan in an attempt to project requirements and to plan for ground test and computational facilities over the coming 20 to 30 years. This report was prepared in response to an AEDC request that the National Research Council (NRC) assemble a committee to prepare guidance for planning and modernizing AEDC facilities for the development and testing of future classes of aerospace systems as envisaged by the U.S. Air Force.

  20. Late rectal toxicity: dose-volume effects of conformal radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Huang, Eugene H.; Pollack, Alan; Levy, Larry; Starkschall, George; Lei Dong; Rosen, Isaac; Kuban, Deborah A.

    2002-01-01

    Purpose: To identify dosimetric, anatomic, and clinical factors that correlate with late rectal toxicity after three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Methods and Materials: We retrospectively analyzed the dose-volume histograms and clinical records of 163 Stage T1b-T3c prostate cancer patients treated between 1992 and 1999 with 3D-CRT, to a total isocenter dose of 74-78 Gy at The University of Texas M. D. Anderson Cancer Center. The median follow-up was 62 months (range 24-102). All late rectal complications were scored using modified Radiation Therapy Oncology Group and Late Effects Normal Tissue Task Force criteria. The 6-year toxicity rate was assessed using Kaplan-Meier analysis and the log-rank test. A univariate proportional hazards regression model was used to test the correlation between Grade 2 or higher toxicity and the dosimetric, anatomic, and clinical factors. In a multivariate regression model, clinical factors were added to the dosimetric and anatomic variables to determine whether they significantly altered the risk of developing late toxicity. Results: At 6 years, the rate of developing Grade 2 or higher late rectal toxicity was 25%. A significant volume effect was observed at rectal doses of 60, 70, 75.6, and 78 Gy, and the risk of developing rectal complications increased exponentially as greater volumes were irradiated. Although the percentage of rectal volume treated correlated significantly with the incidence of rectal complications at all dose levels (p 3 of the rectum. Of the clinical variables tested, only a history of hemorrhoids correlated with rectal toxicity (p=0.003). Multivariate analysis showed that the addition of hemorrhoids increased the risk of toxicity for each dosimetric variable found to be significant on univariate analysis (p<0.05 for all comparisons). Conclusion: Dose-volume histogram analyses clearly indicated a volume effect on the probability of developing late rectal complications

  1. Single-dose volume regulation algorithm for a gas-compensated intrathecal infusion pump.

    Science.gov (United States)

    Nam, Kyoung Won; Kim, Kwang Gi; Sung, Mun Hyun; Choi, Seong Wook; Kim, Dae Hyun; Jo, Yung Ho

    2011-01-01

    The internal pressures of medication reservoirs of gas-compensated intrathecal medication infusion pumps decrease when medication is discharged, and these discharge-induced pressure drops can decrease the volume of medication discharged. To prevent these reductions, the volumes discharged must be adjusted to maintain the required dosage levels. In this study, the authors developed an automatic control algorithm for an intrathecal infusion pump developed by the Korean National Cancer Center that regulates single-dose volumes. The proposed algorithm estimates the amount of medication remaining and adjusts control parameters automatically to maintain single-dose volumes at predetermined levels. Experimental results demonstrated that the proposed algorithm can regulate mean single-dose volumes with a variation of 98%. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Live Operation Data Collection Optimization and Communication for the Domestic Nuclear Detection Office's Rail Test Center

    International Nuclear Information System (INIS)

    Gelston, Gariann M.

    2010-01-01

    For the Domestic Nuclear Detection Office's Rail Test Center (i.e., DNDO's RTC), port operation knowledge with flexible collection tools and technique are essential in both technology testing design and implementation intended for live operational settings. Increased contextual data, flexibility in procedures, and rapid availability of information are keys to addressing the challenges of optimization, validation, and analysis within live operational setting data collection. These concepts need to be integrated into technology testing designs, data collection, validation, and analysis processes. A modified data collection technique with a two phased live operation test method is proposed.

  3. Dedicated Perioperative Hip Fracture Comanagement Programs are Cost-effective in High-volume Centers: An Economic Analysis.

    Science.gov (United States)

    Swart, Eric; Vasudeva, Eshan; Makhni, Eric C; Macaulay, William; Bozic, Kevin J

    2016-01-01

    a full-time basis. Additionally, we evaluated the scenario where the necessary staff was already employed at the hospital and could be dedicated to a comanagement service on a part-time basis, and explored the effect of triaging only patients considered high risk to a comanagement service versus comanaging all geriatric patients. Finally, probabilistic sensitivity analysis was conducted on all critical variables, with broad ranges used for values around which there was higher uncertainty. For the base case, universal comanagement was more cost effective than traditional care and risk-stratified comanagement (incremental cost effectiveness ratios of USD 41,100 per quality-adjusted life-year and USD 81,900 per quality-adjusted life-year, respectively). Comanagement was more cost effective than traditional management as long as the case volume was more than 54 patients annually (range, 41-68 patients based on sensitivity analysis) and resulted in cost savings when there were more than 318 patients annually (range, 238-397 patients). In a scenario where staff could be partially dedicated to a comanagement service, universal comanagement was more cost effective than risk-stratified comanagement (incremental cost effectiveness of USD 2300 per quality-adjusted life-year), and both comanagement programs had lower costs and better outcomes compared with traditional management. Sensitivity analysis was conducted and showed that the level of uncertainty in key variables was not high enough to change the core conclusions of the model. Implementation of a systems-based comanagement strategy using a dedicated team to improve perioperative medical care and expedite preoperative evaluation is cost effective in hospitals with moderate volume and can result in cost savings at higher-volume centers. The optimum patient population for a comanagement strategy is still being defined. Level 1, Economic and Decision Analysis.

  4. Impact of surgical experience on management and outcome of pancreatic surgery performed in high- and low-volume centers.

    Science.gov (United States)

    Stella, Marco; Bissolati, Massimiliano; Gentile, Daniele; Arriciati, Alessandro

    2017-09-01

    Pancreaticoduodenectomy (PD) is one of the procedures in general surgery with the highest rate of life-threatening complications. The positive impact of the volume-outcome ratio on outcomes and mortality in pancreatic surgery (PS) has led to policy-level efforts toward centralization of care for PS that is currently under evaluation by some Regional Health Services. The role of the surgeon's experience and training is still under debate. The aim of this paper is to compare the outcomes of PS by the same surgeon in a high volume (HV) and in a low volume (LV) hospital to assess whether a specific training in PS could outdo the benefits of hospital volume. 124 pancreatic resections (98 PD) were conducted by a single surgeon from 2004 to 2014 in two different Italian hospitals with different PS volumes as well as in general surgical activities. The results were retrospectively analyzed. All data regarding demographics, oncological characteristics, surgical parameters and post-operative outcomes were compared between patients operated on in the HV (group A) and LV hospital (group B). The surgical experience in the LV hospital has been then divided into a first period (group B1) and in a second period (group B2). χ 2 test or Fisher's exact test (when variables were dichotomous) was used. The unpaired t test was used to compare continuous data between the two groups. Values are expressed as n. of cases (percent) for categorical data or as mean (standard deviation) for continuous data. A p value less than 0.05 was considered as significant. From 2004 to 2014, 124 patients underwent pancreatic resection by the same surgeon: 69 in an HV hospital (group A) and 55 in an LV hospital (group B). We focused our attention on PD outcomes, 54 in group A and 44 in group B (22 in group B1 and 22 in group B2, accordingly to the aforementioned criteria). A higher incidence of ASA 3 patients, although not statistically significant, was found in group B than in group A (34 vs. 18%; p

  5. Sweat test and cystic fibrosis: overview of test performance at public and private centers in the state of São Paulo, Brazil.

    Science.gov (United States)

    Servidoni, Maria Fátima; Gomez, Carla Cristina Souza; Marson, Fernando Augusto Lima; Toro, Adyléia Aparecida Dalbo Contrera; Ribeiro, Maria Ângela Gonçalves de Oliveira; Ribeiro, José Dirceu; Ribeiro, Antônio Fernando

    2017-01-01

    The sweat test (ST) measures chloride levels in sweat and is considered the gold standard for the diagnosis of cystic fibrosis (CF). However, the reliability of a ST depends on their being performed by experienced technicians and in accordance with strict guidelines. Our aim was to evaluate how sweat stimulation, sweat collection, and chloride measurement are performed at 14 centers (9 public centers and 5 private centers) that routinely perform STs in the state of São Paulo, which has the highest frequency of CF in Brazil. This was a cross-sectional cohort study, using a standardized questionnaire administered in loco to the staff responsible for conducting STs. No uniformity regarding the procedures was found among the centers. Most centers were noncompliant with the international guidelines, especially regarding the collection of sweat (the samples were insufficient in 10-50% of the subjects tested); availability of stimulation equipment (which was limited at 2 centers); modernity and certification of stimulation equipment (most of the equipment having been used for 3-23 years); and written protocols (which were lacking at 12 centers). Knowledge of ST guidelines was evaluated at only 1 center. Our results show that STs largely deviate from internationally accepted guidelines at the participating centers. Therefore, there is an urgent need for standardization of STs, training of qualified personnel, and acquisition/certification of suitable equipment. These are essential conditions for a reliable diagnosis of CF, especially with the increasing demand due to newborn screening nationwide, and for the assessment of a possible clinical benefit from the use of modulator drugs. O teste do suor (TS) mede os níveis de cloro no suor e é considerado o padrão ouro para o diagnóstico da fibrose cística (FC). Contudo, a confiabilidade do TS depende de sua realização por técnicos experientes e segundo diretrizes rígidas. Nosso objetivo foi avaliar como s

  6. Collins Center Update. Volume 2, Issue 2, July-September 2000

    National Research Council Canada - National Science Library

    Kievit, James; Perlmutter, Jim; Griffard, B. F; Auger, John; Grindle, Charles

    2000-01-01

    Power Projection Wargame II, Peace Operations Conference, Logistics Futures Roundtable, Logisticians Prep for the Next ATWG, Collins Center Upgrades, Global '00, Joint Flag Officer Warfighting Course (JFOWC...

  7. Variation in Structure and Process of Care in Traumatic Brain Injury: Provider Profiles of European Neurotrauma Centers Participating in the CENTER-TBI Study.

    Directory of Open Access Journals (Sweden)

    Maryse C Cnossen

    Full Text Available The strength of evidence underpinning care and treatment recommendations in traumatic brain injury (TBI is low. Comparative effectiveness research (CER has been proposed as a framework to provide evidence for optimal care for TBI patients. The first step in CER is to map the existing variation. The aim of current study is to quantify variation in general structural and process characteristics among centers participating in the Collaborative European NeuroTrauma Effectiveness Research in Traumatic Brain Injury (CENTER-TBI study.We designed a set of 11 provider profiling questionnaires with 321 questions about various aspects of TBI care, chosen based on literature and expert opinion. After pilot testing, questionnaires were disseminated to 71 centers from 20 countries participating in the CENTER-TBI study. Reliability of questionnaires was estimated by calculating a concordance rate among 5% duplicate questions.All 71 centers completed the questionnaires. Median concordance rate among duplicate questions was 0.85. The majority of centers were academic hospitals (n = 65, 92%, designated as a level I trauma center (n = 48, 68% and situated in an urban location (n = 70, 99%. The availability of facilities for neuro-trauma care varied across centers; e.g. 40 (57% had a dedicated neuro-intensive care unit (ICU, 36 (51% had an in-hospital rehabilitation unit and the organization of the ICU was closed in 64% (n = 45 of the centers. In addition, we found wide variation in processes of care, such as the ICU admission policy and intracranial pressure monitoring policy among centers.Even among high-volume, specialized neurotrauma centers there is substantial variation in structures and processes of TBI care. This variation provides an opportunity to study effectiveness of specific aspects of TBI care and to identify best practices with CER approaches.

  8. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  9. Challenges in defining a radiologic and hydrologic source term for underground nuclear test centers, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Smith, D.K.

    1995-06-01

    The compilation of a radionuclide inventory for long-lived radioactive contaminants residual from nuclear testing provides a partial measure of the radiologic source term at the Nevada Test Site. The radiologic source term also includes potentially mobile short-lived radionuclides excluded from the inventory. The radiologic source term for tritium is known with accuracy and is equivalent to the hydrologic source term within the saturated zone. Definition of the total hydrologic source term for fission and activation products that have high activities for decades following underground testing involves knowledge and assumptions which are presently unavailable. Systematic investigation of the behavior of fission products, activation products and actinides under saturated or Partially saturated conditions is imperative to define a representative total hydrologic source term. This is particularly important given the heterogeneous distribution of radionuclides within testing centers. Data quality objectives which emphasize a combination of measurements and credible estimates of the hydrologic source term are a priority for near-field investigations at the Nevada Test Site

  10. Repeat HIV Testing at Voluntary Testing and Counseling Centers in Croatia: Successful HIV Prevention or Failure to Modify Risk Behaviors?

    Science.gov (United States)

    Matković Puljić, Vlatka; Kosanović Ličina, Mirjana Lana; Kavić, Marija; Nemeth Blažić, Tatjana

    2014-01-01

    HIV testing plays a critical role in preventing the spread of the virus and identifying infected individuals in need of care. Voluntary counseling and testing centers (VCTs) not only conduct testing but they also provide counseling. Since a proportion of people who test negative for HIV on their previous visit will return for retesting, the frequency of retesting and the characteristics of those who retest may provide insights into the efficacy of testing and counseling strategies. In this cross-sectional, retrospective study of 1,482 VCT clients in Croatia in 2010, 44.3% had been tested for HIV before. The rate of repeat HIV testing is lower in Croatia than in other countries. Men who have sex with men (MSM) clients, those with three or more sexual partners in the last 12 months, consistent condom users with steady partners, and intravenous drug users were more likely to be repeat testers. This finding suggests that clients presenting for repeat HIV testing are those who self-identify as being at a higher risk of infection. Our data showed that testing positive for HIV was not associated with repeat testing. However, the effects of repeat testing on HIV epidemiology needs to be explored. PMID:24705595

  11. MRI volume measurement of basal ganglia volumes in patients with Tourette's syndrome

    International Nuclear Information System (INIS)

    Lu Jie; Li Kuncheng; Cao Yanxiang; Zhang Miao; Sui Xin; Zhang Xiaohua

    2009-01-01

    Objective: To evaluate MRI measurement of basal ganglia volumes in patients with Tourette's syndrome. Methods: Ten patients with Tourette's syndrome (TS) and 10 healthy volunteers were studied. Volumes of bilateral caudate, putamen and pallidum were measured, and the results were analyzed using paired t test. The basal ganglia volume was normalized according to individual brain volume. The basal ganglia volumes of TS patients were compared with normal control group using independent-sample t test. Results: In 10 healthy volunteers, volumes of the left caudate, putamen, pallidum were significantly larger compared with those of the right side (P 0.05) in TS patients. After normalized processing, the volumes of the left caudate (7.06 ± 0.48) cm 3 , putamen (8.81±1.01) cm 3 , pallidum (2.64± 0.38) cm 3 were smaller than those of control group [caudate (11.05±1.86) cm 3 , putamen (9.97± 1.11) cm 3 , pallidum (3.04±0.37) cm 3 ] (t=-6.577, -2.457, -2.376, P 3 in TS patients was significantly smaller compared with the control group (9.81±1.83) cm 3 (t=-4.258, P 0.05). Conclusion: The basal ganglia volumes were significantly decreased in patients with TS. MRI volumetric measurement was an important tool for evaluating pathologic changes of TS. (authors)

  12. The Collins Center Update. Volume 1, Issue 3, December 1999

    National Research Council Canada - National Science Library

    Harvey, Kevin; Wasiak, Joe; Kievit, James; Griffard, B. F; Blotzer, Larry

    1999-01-01

    ...: Kentucky Governor Patton Kicks Off the Center for Strategic Leadership's (CSL) Senior Executive Program, Global Guardian Exercise '99, Global Wargame '99, Democratization Initiatives Support Simulation, Deterrence in the 21st Century Symposium...

  13. User-centered design

    International Nuclear Information System (INIS)

    Baik, Joo Hyun; Kim, Hyeong Heon

    2008-01-01

    The simplification philosophy, as an example, that both of EPRI-URD and EUR emphasize is treated mostly for the cost reduction of the nuclear power plants, but not for the simplification of the structure of user's tasks, which is one of the principles of user-centered design. A user-centered design is a philosophy based on the needs and interests of the user, with an emphasis on making products usable and understandable. However, the nuclear power plants offered these days by which the predominant reactor vendors are hardly user-centered but still designer-centered or technology-centered in viewpoint of fulfilling user requirements. The main goal of user-centered design is that user requirements are elicited correctly, reflected properly into the system requirements, and verified thoroughly by the tests. Starting from the user requirements throughout to the final test, each requirement should be traceable. That's why requirement traceability is a key to the user-centered design, and main theme of a requirement management program, which is suggested to be added into EPRI-URD and EUR in the section of Design Process. (author)

  14. Finite volume schemes with equilibrium type discretization of source terms for scalar conservation laws

    International Nuclear Information System (INIS)

    Botchorishvili, Ramaz; Pironneau, Olivier

    2003-01-01

    We develop here a new class of finite volume schemes on unstructured meshes for scalar conservation laws with stiff source terms. The schemes are of equilibrium type, hence with uniform bounds on approximate solutions, valid in cell entropy inequalities and exact for some equilibrium states. Convergence is investigated in the framework of kinetic schemes. Numerical tests show high computational efficiency and a significant advantage over standard cell centered discretization of source terms. Equilibrium type schemes produce accurate results even on test problems for which the standard approach fails. For some numerical tests they exhibit exponential type convergence rate. In two of our numerical tests an equilibrium type scheme with 441 nodes on a triangular mesh is more accurate than a standard scheme with 5000 2 grid points

  15. Liver Resections in a High-Volume Center: Form Standard Procedures to Extreme Surgery and Ultrasound-guided Resections.

    Science.gov (United States)

    Botea, Florin; Ionescu, Mihnea; Braşoveanu, Vladislav; Hrehoreţ, Doina; Alexandrescu, Sorin; Grigorie, Mihai; Stanciulea, Oana; Nicolaescu, Diana; Tomescu, Dana; Droc, Gabriela; Ungureanu, Daniela; Fota, Ruxandra; Croitoru, Adina; Gheorghe, Liana; Gheorghe, Cristian; Lupescu, Ioana; Grasu, Mugur; Boroş, Mirela; Dumitru, Radu; Toma, Mihai; Herlea, Vlad; Popescu, Irinel

    2017-01-01

    Background: Liver resection (LR) is the treatment of choice for most benign and malignant focal liver lesions, as well as in selected patients with liver trauma. Few other therapies can compete with LR in selected cases, such as liver transplantation in hepatocellular carcinoma (HCC) and ablative therapies in small HCCs or liver metastases. The present paper analyses a single center experience in LR, reviewing the indications of LR, the operative techniques and their short-term results. Between January 2000 and December 2016, in "œDan Setlacec" Center of General Surgery and Liver Transplantation were performed 3165 LRs in 3016 patients, for pathologic conditions of the liver. In the present series, liver resections for living-donor liver transplantation were excluded. The median age of the patients was 56 years (mean 58 years; range 1-88), with male/female ratio 1524/1492 and adult/pediatric patient ratio 2973/43. Results: Malignant lesions were the main indication for LR (2372 LRs; 74.9%). Among these, colorectal liver metastases were the most frequent indication (952 LRs; 30.1%), followed by hepatocellular carcinoma (575 patients, 18.2%). The highest number of resected tumors per patient was 21, and the median diameter of the largest tumor was 40 mm (mean 51 mm; range 3-250). Major resections rate was 18.6% (588 LRs) and anatomical LRs were performed in 789 patients (24.9%). The median operative time was 180 minutes (mean 204 minutes; range 45-920). The median blood loss was 500 ml (mean 850 ml; range 500-9500), with a transfusion rate of 41.6% (1316 LRs). The morbidity rate was 40.1% (1270 LRs) and the rate of major complications (Dindo-Clavien IIIa or more) was 13.2% (418 LRs). Mortality rate was 4.2% (127 pts). LRs should be performed in specialized high-volume centers to achieve the best results (low morbidity and mortality rates). Celsius.

  16. Mars power system concept definition study. Volume 2: Appendices

    Science.gov (United States)

    Littman, Franklin D.

    1994-01-01

    This report documents the work performed by Rockwell International's Rocketdyne Division on NASA Contract No. NAS3-25808 (Task Order No. 16) entitled 'Mars Power System Definition Study'. This work was performed for NASA's Lewis Research Center (LeRC). The report is divided into two volumes as follows: Volume 1 - Study Results; and Volume 2 - Appendices. The results of the power system characterization studies, operations studies, and technology evaluations are summarized in Volume 1. The appendices include complete, standalone technology development plans for each candidate power system that was investigated.

  17. Variation in Annual Volume at a University Hospital Does Not Predict Mortality for Pancreatic Resections

    Directory of Open Access Journals (Sweden)

    Rita A. Mukhtar

    2008-01-01

    Full Text Available Annual volume of pancreatic resections has been shown to affect mortality rates, prompting recommendations to regionalize these procedures to high-volume hospitals. Implementation has been difficult, given the paucity of high-volume centers and the logistical hardships facing patients. Some studies have shown that low-volume hospitals achieve good outcomes as well, suggesting that other factors are involved. We sought to determine whether variations in annual volume affected patient outcomes in 511 patients who underwent pancreatic resections at the University of California, San Francisco between 1990 and 2005. We compared postoperative mortality and complication rates between low, medium, or high volume years, designated by the number of resections performed, adjusting for patient characteristics. Postoperative mortality rates did not differ between high volume years and medium/low volume years. As annual hospital volume of pancreatic resections may not predict outcome, identification of actual predictive factors may allow low-volume centers to achieve excellent outcomes.

  18. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?

    Science.gov (United States)

    Bachiller, Patricia R; McDonough, Joseph M; Feldman, Jeffrey M

    2008-05-01

    During mechanical ventilation of infants and neonates, small changes in tidal volume may lead to hypo- or hyperventilation, barotrauma, or volutrauma. Partly because breathing circuit compliance and fresh gas flow affect tidal volume delivery by traditional anesthesia ventilators in volume-controlled ventilation (VCV) mode, pressure-controlled ventilation (PCV) using a circle breathing system has become a common approach to minimizing the risk of mechanical ventilation for small patients, although delivered tidal volume is not assured during PCV. A new generation of anesthesia machine ventilators addresses the problems of VCV by adjusting for fresh gas flow and for the compliance of the breathing circuit. In this study, we evaluated the accuracy of new anesthesia ventilators to deliver small tidal volumes. Four anesthesia ventilator systems were evaluated to determine the accuracy of volume delivery to the airway during VCV at tidal volume settings of 100, 200, and 500 mL under different conditions of breathing circuit compliance (fully extended and fully contracted circuits) and lung compliance. A mechanical test lung (adult and infant) was used to simulate lung compliances ranging from 0.0025 to 0.03 L/cm H(2)O. Volumes and pressures were measured using a calibrated screen pneumotachograph and custom software. We tested the Smartvent 7900, Avance, and Aisys anesthesia ventilator systems (GE Healthcare, Madison, WI) and the Apollo anesthesia ventilator (Draeger Medical, Telford, PA). The Smartvent 7900 and Avance ventilators use inspiratory flow sensors to control the volume delivered, whereas the Aisys and Apollo ventilators compensate for the compliance of the circuit. We found that the anesthesia ventilators that use compliance compensation (Aisys and Apollo) accurately delivered both large and small tidal volumes to the airway of the test lung under conditions of normal and low lung compliance during VCV (ranging from 95.5% to 106.2% of the set tidal volume

  19. Toward Semi-automated Assessment of Target Volume Delineation in Radiotherapy Trials: The SCOPE 1 Pretrial Test Case

    Energy Technology Data Exchange (ETDEWEB)

    Gwynne, Sarah, E-mail: Sarah.Gwynne2@wales.nhs.uk [Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales (United Kingdom); Spezi, Emiliano; Wills, Lucy [Department of Medical Physics, Velindre Cancer Centre, Cardiff, Wales (United Kingdom); Nixon, Lisette; Hurt, Chris [Wales Cancer Trials Unit, School of Medicine, Cardiff University, Cardiff, Wales (United Kingdom); Joseph, George [Department of Diagnostic Radiology, Velindre Cancer Centre, Cardiff, Wales (United Kingdom); Evans, Mererid [Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales (United Kingdom); Griffiths, Gareth [Wales Cancer Trials Unit, School of Medicine, Cardiff University, Cardiff, Wales (United Kingdom); Crosby, Tom [Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales (United Kingdom); Staffurth, John [Division of Cancer, School of Medicine, Cardiff University, Cardiff, Wales (United Kingdom)

    2012-11-15

    Purpose: To evaluate different conformity indices (CIs) for use in the analysis of outlining consistency within the pretrial quality assurance (Radiotherapy Trials Quality Assurance [RTTQA]) program of a multicenter chemoradiation trial of esophageal cancer and to make recommendations for their use in future trials. Methods and Materials: The National Cancer Research Institute SCOPE 1 trial is an ongoing Cancer Research UK-funded phase II/III randomized controlled trial of chemoradiation with capecitabine and cisplatin with or without cetuximab for esophageal cancer. The pretrial RTTQA program included a detailed radiotherapy protocol, an educational package, and a single mid-esophageal tumor test case that were sent to each investigator to outline. Investigator gross tumor volumes (GTVs) were received from 50 investigators in 34 UK centers, and CERR (Computational Environment for Radiotherapy Research) was used to perform an assessment of each investigator GTV against a predefined gold-standard GTV using different CIs. A new metric, the local conformity index (l-CI), that can localize areas of maximal discordance was developed. Results: The median Jaccard conformity index (JCI) was 0.69 (interquartile range, 0.62-0.70), with 14 of 50 investigators (28%) achieving a JCI of 0.7 or greater. The median geographical miss index was 0.09 (interquartile range, 0.06-0.16), and the mean discordance index was 0.27 (95% confidence interval, 0.25-0.30). The l-CI was highest in the middle section of the volume, where the tumor was bulky and more easily definable, and identified 4 slices where fewer than 20% of investigators achieved an l-CI of 0.7 or greater. Conclusions: The available CIs analyze different aspects of a gold standard-observer variation, with JCI being the most useful as a single metric. Additional information is provided by the l-CI and can focus the efforts of the RTTQA team in these areas, possibly leading to semi-automated outlining assessment.

  20. Toward Semi-automated Assessment of Target Volume Delineation in Radiotherapy Trials: The SCOPE 1 Pretrial Test Case

    International Nuclear Information System (INIS)

    Gwynne, Sarah; Spezi, Emiliano; Wills, Lucy; Nixon, Lisette; Hurt, Chris; Joseph, George; Evans, Mererid; Griffiths, Gareth; Crosby, Tom; Staffurth, John

    2012-01-01

    Purpose: To evaluate different conformity indices (CIs) for use in the analysis of outlining consistency within the pretrial quality assurance (Radiotherapy Trials Quality Assurance [RTTQA]) program of a multicenter chemoradiation trial of esophageal cancer and to make recommendations for their use in future trials. Methods and Materials: The National Cancer Research Institute SCOPE 1 trial is an ongoing Cancer Research UK-funded phase II/III randomized controlled trial of chemoradiation with capecitabine and cisplatin with or without cetuximab for esophageal cancer. The pretrial RTTQA program included a detailed radiotherapy protocol, an educational package, and a single mid-esophageal tumor test case that were sent to each investigator to outline. Investigator gross tumor volumes (GTVs) were received from 50 investigators in 34 UK centers, and CERR (Computational Environment for Radiotherapy Research) was used to perform an assessment of each investigator GTV against a predefined gold-standard GTV using different CIs. A new metric, the local conformity index (l-CI), that can localize areas of maximal discordance was developed. Results: The median Jaccard conformity index (JCI) was 0.69 (interquartile range, 0.62-0.70), with 14 of 50 investigators (28%) achieving a JCI of 0.7 or greater. The median geographical miss index was 0.09 (interquartile range, 0.06-0.16), and the mean discordance index was 0.27 (95% confidence interval, 0.25-0.30). The l-CI was highest in the middle section of the volume, where the tumor was bulky and more easily definable, and identified 4 slices where fewer than 20% of investigators achieved an l-CI of 0.7 or greater. Conclusions: The available CIs analyze different aspects of a gold standard–observer variation, with JCI being the most useful as a single metric. Additional information is provided by the l-CI and can focus the efforts of the RTTQA team in these areas, possibly leading to semi-automated outlining assessment.

  1. Performance of five research-domain automated WM lesion segmentation methods in a multi-center MS study

    DEFF Research Database (Denmark)

    de Sitter, Alexandra; Steenwijk, Martijn D; Ruet, Aurélie

    2017-01-01

    (Lesion-TOADS); and k-Nearest Neighbor with Tissue Type Priors (kNN-TTP). Main software parameters were optimized using a training set (N = 18), and formal testing was performed on the remaining patients (N = 52). To evaluate volumetric agreement with the reference segmentations, intraclass correlation......BACKGROUND AND PURPOSE: In vivoidentification of white matter lesions plays a key-role in evaluation of patients with multiple sclerosis (MS). Automated lesion segmentation methods have been developed to substitute manual outlining, but evidence of their performance in multi-center investigations......-one-center-out design to exclude the center of interest from the training phase to evaluate the performance of the method on 'unseen' center. RESULTS: Compared to the reference mean lesion volume (4.85 ± 7.29 mL), the methods displayed a mean difference of 1.60 ± 4.83 (Cascade), 2.31 ± 7.66 (LGA), 0.44 ± 4.68 (LPA), 1...

  2. Impact of HPV testing, HPV vaccine development, and changing screening frequency on national Pap test volume: projections from the National Health Interview Survey (NHIS).

    Science.gov (United States)

    Eltoum, Isam A; Roberson, Janie

    2007-02-25

    The frequently cited number of 50 million annual Papanicolaou cervical screening (Pap) tests performed in the US was based on the National Health Interview Survey (NHIS) of the 1980s. Since then, monumental changes have occurred. More change will soon follow when primary human papilloma virus (HPV) testing and/or HPV vaccine delivery are fully accepted and implemented. The objectives of this study were 1) to estimate the total annual Pap tests performed in the US based on recent NHIS surveys, and 2) to estimate the potential change in the total annual Pap volume produced by changing demographics, reduced screening frequency, HPV testing, and the HPV vaccine. In the NHIS 2000 and NHIS 2005, women were asked to report the frequency of their Pap tests for the 6 years prior to the interview and to report whether they had abnormal findings. The authors analyzed the survey respondents answers to these questions by using SAS Survey Procedures (SAS Institute, NC). The results were stratified by age, and the total national volume was then extrapolated from a similarly stratified 2000 US census. The projected increase of total Pap tests for the next 25 years was determined by using the projected census data. Potential reductions of Pap tests performed secondarily to HPV testing of women >30 years old and of HPV vaccination were also determined. Based on NHIS 2000 and NHIS 2005, 66 million (95% CI, 65-68) and 65 million (95% CI, 64-67) Pap tests were performed in the US, respectively. Had HPV testing been performed in women older than 30 years who had both negative HPV and negative 3-year Pap tests, then 30% (95% CI, 29-32%) of Pap tests would not have been performed. If both HPV testing and vaccination are performed, the total number of Pap tests performed annually is predicted to be reduced by 43% (95% CI, 35-38%). Therefore, despite an expected increase in the population of women eligible for Pap tests, the total number will likely decrease substantially in the future

  3. Testing of the Advanced Stirling Radioisotope Generator Engineering Unit at NASA Glenn Research Center

    Science.gov (United States)

    Lewandowski, Edward J.

    2013-01-01

    The Advanced Stirling Radioisotope Generator (ASRG) is a high-efficiency generator being developed for potential use on a Discovery 12 space mission. Lockheed Martin designed and fabricated the ASRG Engineering Unit (EU) under contract to the Department of Energy. This unit was delivered to NASA Glenn Research Center in 2008 and has been undergoing extended operation testing to generate long-term performance data for an integrated system. It has also been used for tests to characterize generator operation while varying control parameters and system inputs, both when controlled with an alternating current (AC) bus and with a digital controller. The ASRG EU currently has over 27,000 hours of operation. This paper summarizes all of the tests that have been conducted on the ASRG EU over the past 3 years and provides an overview of the test results and what was learned.

  4. Centers for Disease Control and Prevention Funding for HIV Testing Associated With Higher State Percentage of Persons Tested.

    Science.gov (United States)

    Hayek, Samah; Dietz, Patricia M; Van Handel, Michelle; Zhang, Jun; Shrestha, Ram K; Huang, Ya-Lin A; Wan, Choi; Mermin, Jonathan

    2015-01-01

    To assess the association between state per capita allocations of Centers for Disease Control and Prevention (CDC) funding for HIV testing and the percentage of persons tested for HIV. We examined data from 2 sources: 2011 Behavioral Risk Factor Surveillance System and 2010-2011 State HIV Budget Allocations Reports. Behavioral Risk Factor Surveillance System data were used to estimate the percentage of persons aged 18 to 64 years who had reported testing for HIV in the last 2 years in the United States by state. State HIV Budget Allocations Reports were used to calculate the state mean annual per capita allocations for CDC-funded HIV testing reported by state and local health departments in the United States. The association between the state fixed-effect per capita allocations for CDC-funded HIV testing and self-reported HIV testing in the last 2 years among persons aged 18 to 64 years was assessed with a hierarchical logistic regression model adjusting for individual-level characteristics. The percentage of persons tested for HIV in the last 2 years. In 2011, 18.7% (95% confidence interval = 18.4-19.0) of persons reported being tested for HIV in last 2 years (state range, 9.7%-28.2%). During 2010-2011, the state mean annual per capita allocation for CDC-funded HIV testing was $0.34 (state range, $0.04-$1.04). A $0.30 increase in per capita allocation for CDC-funded HIV testing was associated with an increase of 2.4 percentage points (14.0% vs 16.4%) in the percentage of persons tested for HIV per state. Providing HIV testing resources to health departments was associated with an increased percentage of state residents tested for HIV.

  5. Understanding the relationship between the Centers for Medicare and Medicaid Services' Hospital Compare star rating, surgical case volume, and short-term outcomes after major cancer surgery.

    Science.gov (United States)

    Kaye, Deborah R; Norton, Edward C; Ellimoottil, Chad; Ye, Zaojun; Dupree, James M; Herrel, Lindsey A; Miller, David C

    2017-11-01

    Both the Centers for Medicare and Medicaid Services' (CMS) Hospital Compare star rating and surgical case volume have been publicized as metrics that can help patients to identify high-quality hospitals for complex care such as cancer surgery. The current study evaluates the relationship between the CMS' star rating, surgical volume, and short-term outcomes after major cancer surgery. National Medicare data were used to evaluate the relationship between hospital star ratings and cancer surgery volume quintiles. Then, multilevel logistic regression models were fit to examine the association between cancer surgery outcomes and both star rankings and surgical volumes. Lastly, a graphical approach was used to compare how well star ratings and surgical volume predicted cancer surgery outcomes. This study identified 365,752 patients undergoing major cancer surgery for 1 of 9 cancer types at 2,550 hospitals. Star rating was not associated with surgical volume (P cancer surgery outcomes (mortality, complication rate, readmissions, and prolonged length of stay). The adjusted predicted probabilities for 5- and 1-star hospitals were 2.3% and 4.5% for mortality, 39% and 48% for complications, 10% and 15% for readmissions, and 8% and 16% for a prolonged length of stay, respectively. The adjusted predicted probabilities for hospitals with the highest and lowest quintile cancer surgery volumes were 2.7% and 5.8% for mortality, 41% and 55% for complications, 12.2% and 11.6% for readmissions, and 9.4% and 13% for a prolonged length of stay, respectively. Furthermore, surgical volume and the star rating were similarly associated with mortality and complications, whereas the star rating was more highly associated with readmissions and prolonged length of stay. In the absence of other information, these findings suggest that the star rating may be useful to patients when they are selecting a hospital for major cancer surgery. However, more research is needed before these ratings can

  6. Detailed requirements document for the Interactive Financial Management System (IFMS), volume 1

    Science.gov (United States)

    Dodson, D. B.

    1975-01-01

    The detailed requirements for phase 1 (online fund control, subauthorization accounting, and accounts receivable functional capabilities) of the Interactive Financial Management System (IFMS) are described. This includes information on the following: systems requirements, performance requirements, test requirements, and production implementation. Most of the work is centered on systems requirements, and includes discussions on the following processes: resources authority, allotment, primary work authorization, reimbursable order acceptance, purchase request, obligation, cost accrual, cost distribution, disbursement, subauthorization performance, travel, accounts receivable, payroll, property, edit table maintenance, end-of-year, backup input. Other subjects covered include: external systems interfaces, general inquiries, general report requirements, communication requirements, and miscellaneous. Subjects covered under performance requirements include: response time, processing volumes, system reliability, and accuracy. Under test requirements come test data sources, general test approach, and acceptance criteria. Under production implementation come data base establishment, operational stages, and operational requirements.

  7. SLRV Engineering Tests at Department of Transportation Transportation Test Center : Volume 1. Introduction.

    Science.gov (United States)

    1979-01-01

    The Standard Light Rail Vehicle (SLRV) is a 71-foot vehicle, articulated to negotiate curves down to 32-foot radius and designed to operate at speeds up to 50 mph. Although the basic configuration and performance is standardized, the current operatin...

  8. Determinants of domestic violence among women attending an human immunodeficiency virus voluntary counseling and testing center in Bangalore, India.

    Science.gov (United States)

    Chandrasekaran, Varalakshmi; Krupp, Karl; George, Ruja; Madhivanan, Purnima

    2007-05-01

    Violence against women is a global phenomenon that cuts across all social and economic classes. This study was designed to measure the prevalence and correlates of domestic violence (DV) among women seeking services at a voluntary counseling and testing (VCT) center in Bangalore, India. A cross-sectional survey was conducted among women visiting an human immunodeficiency virus (HIV) VCT center in Bangalore, between September and November 2005. An interviewer-administered questionnaire was used to collect information about violence and other variables. Univariable associations with DV were made using Pearson Chi-squared test for categorical variables and Student t-test or the Mann-Whitney test for continuous variables. Forty-two percent of respondents reported DV, including physical abuse (29%), psychological abuse (69%) and sexual abuse (1%). Among the women who reported violence of any kind, 67% also reported that they were HIV seropositive. The most common reasons reported for DV included financial problems (38%), husband's alcohol use (29%) and woman's HIV status (18%). Older women (P around the world. The findings highlight the need for additional training among health care providers in VCT centers in screening for DV, detection of signs of physical abuse and provisions and referrals for women suffering from domestic partner violence.

  9. Using clinical simulation centers to test design interventions: a pilot study of lighting and color modifications.

    Science.gov (United States)

    Gray, Whitney Austin; Kesten, Karen S; Hurst, Stephen; Day, Tama Duffy; Anderko, Laura

    2012-01-01

    The aim of this pilot study was to test design interventions such as lighting, color, and spatial color patterning on nurses' stress, alertness, and satisfaction, and to provide an example of how clinical simulation centers can be used to conduct research. The application of evidence-based design research in healthcare settings requires a transdisciplinary approach. Integrating approaches from multiple fields in real-life settings often proves time consuming and experimentally difficult. However, forums for collaboration such as clinical simulation centers may offer a solution. In these settings, identical operating and patient rooms are used to deliver simulated patient care scenarios using automated mannequins. Two identical rooms were modified in the clinical simulation center. Nurses spent 30 minutes in each room performing simulated cardiac resuscitation. Subjective measures of nurses' stress, alertness, and satisfaction were collected and compared between settings and across time using matched-pair t-test analysis. Nurses reported feeling less stressed after exposure to the experimental room than nurses who were exposed to the control room (2.22, p = .03). Scores post-session indicated a significant reduction in stress and an increase in alertness after exposure to the experimental room as compared to the control room, with significance levels below .10. (Change in stress scores: 3.44, p = .069); (change in alertness scores: 3.6, p = .071). This study reinforces the use of validated survey tools to measure stress, alertness, and satisfaction. Results support human-centered design approaches by evaluating the effect on nurses in an experimental setting.

  10. Analysis of differences in outcome of two European liver transplant centers

    NARCIS (Netherlands)

    Nemes, B; Polak, W; Ther, G; Hendriks, H; Kobori, L; Porte, RJ; Sarvary, E; de Jong, KP; Doros, A; Gerlei, Z; van den Berg, AP; Fehervari, [No Value; Gorog, D; Peeters, PM; Jaray, J; Slooff, MJH

    Authors analyzed the differences in the outcome of two European liver transplant centers differing in case volume and experience. The first was the Transplantation and Surgical Clinic, Semmelweis University, Budapest, Hungary (SEB) and the second the University Medical Center Groningen, Groningen,

  11. Application of SLIM-MAUD: A test of an interactive computer-based method for organizing expert assessment of human performance and reliability: Volume 2, Appendices

    International Nuclear Information System (INIS)

    Spettell, C.M.; Rosa, E.A.; Humphreys, P.C.; Embrey, D.E.

    1986-10-01

    The US Nuclear Regulatory Commission (NRC) has been conducting a multiyear research program to investigate different methods for using expert judgments to estimate human error probabilities (HEPs) in nuclear power plants. One of the methods investigated, derived from multi-attribute utility theory, is the Success Likelihood Index Methodolocy implemented through Multi-Attribute Utility Decomposition (SLIM-MAUD). This report describes a systematic test application of the SLIM-MAUD methodology. The test application is evaluated on the basis of three criteria: practicality, acceptability, and usefulness. Volume I of this report represents an overview of SLIM-MAUD, describes the procedures followed in the test application, and provides a summary of the results obtained. Volume II consists of technical appendices to support in detail the materials contained in Volume I, and the users' package of explicit procedures to be followed in implementing SLIM-MAUD. The results obtained in the test application provide support for the application of SLIM-MAUD to a wide variety of applications requiring estimates of human errors

  12. Increasing preload volume with water reduces rated appetite but not food intake in healthy men even with minimum delay between preload and test meal.

    Science.gov (United States)

    Gray, Richard W; French, Stephen J; Robinson, Tristan M; Yeomans, Martin R

    2003-02-01

    The role of gastric volume in the short-term control of eating in humans remains unclear, with some studies reporting that food volume alone can reduce appetite but others finding no such effect. A recent study in our laboratory, found effects of preload volume on subjective appetite (hunger, fullness) but not intake, and found effects of preload energy on intake but not appetite. That study used an interval of 30 min between serving preloads and the test meal, and the present study attempted to maximise the effects of the volume manipulation by removing the delay between the preload and test meal. We administered four soup-based preloads varying in volume (150 and 450 ml) using water, and energy density (1.4 and 4.2 kJ/ml) using maltodextrin, producing three energy levels (209, 629, 629 and 1886 kJ; repeated measures). These were followed immediately by an unlimited hot pasta lunch, during which food weight was monitored continuously by computer. Increasing soup volume at constant energy (629 kJ) reduced appetite ratings, but not intake. In contrast, increasing soup energy at constant volume (450 ml) reduced intake, without affecting appetite. The discrepancies between our results and other reported studies suggest that volume is more influential when intakes are large, or that there may be a threshold concentration for nutrients in the GI tract before volume alone is tangibly expressed in subsequent eating.

  13. Documentation and archiving of the Space Shuttle wind tunnel test data base. Volume 1: Background and description

    Science.gov (United States)

    Romere, Paul O.; Brown, Steve Wesley

    1995-01-01

    Development of the space shuttle necessitated an extensive wind tunnel test program, with the cooperation of all the major wind tunnels in the United States. The result was approximately 100,000 hours of space shuttle wind tunnel testing conducted for aerodynamics, heat transfer, and structural dynamics. The test results were converted into Chrysler DATAMAN computer program format to facilitate use by analysts, a very cost effective method of collecting the wind tunnel test results from many test facilities into one centralized location. This report provides final documentation of the space shuttle wind tunnel program. The two-volume set covers evolution of space shuttle aerodynamic configurations and gives wind tunnel test data, titles of wind tunnel data reports, sample data sets, and instructions for accessing the digital data base.

  14. Distributing CMS Data between the Florida T2 and T3 Centers using Lustre and Xrootd-fs

    International Nuclear Information System (INIS)

    Kaganas, G; Rodriguez, J L; Cheng, M; Avery, P; Bourilkov, D; Fu, Y; Palencia, J

    2014-01-01

    We have developed remote data access for large volumes of data over the Wide Area Network based on the Lustre filesystem and Kerberos authentication for security. In this paper we explore a prototype for two-step data access from worker nodes at Florida Tier3 centers, located behind a firewall and using a private network, to data hosted on the Lustre filesystem at the University of Florida CMS Tier2 center. At the Tier3 center we use a client which mounts securely the Lustre filesystem and hosts an XrootD server. The worker nodes access the data from the Tier3 client using POSIX compliant tools via the XrootD-fs filesystem. We perform scalability tests with up to 200 jobs running in parallel on the Tier3 worker nodes.

  15. Cardiac chamber volumes by echocardiography using a new mathematical method: A promising technique for zero-G use

    Science.gov (United States)

    Buckey, J. C.; Beattie, J. M.; Gaffney, F. A.; Nixon, J. V.; Blomqvist, C. G.

    1984-01-01

    Accurate, reproducible, and non-invasive means for ventricular volume determination are needed for evaluating cardiovascular function zero-gravity. Current echocardiographic methods, particularly for the right ventricle, suffer from a large standard error. A new mathematical approach, recently described by Watanabe et al., was tested on 1 normal formalin-fixed human hearts suspended in a mineral oil bath. Volumes are estimated from multiple two-dimensional echocardiographic views recorded from a single point at sequential angles. The product of sectional cavity area and center of mass for each view summed over the range of angles (using a trapezoidal rule) gives volume. Multiple (8-14) short axis right ventricle and left ventricle views at 5.0 deg intervals were videotaped. The images were digitized by two independent observers (leading-edge to leading-edge technique) and analyzed using a graphics tablet and microcomputer. Actual volumes were determined by filling the chambers with water. These data were compared to the mean of the two echo measurements.

  16. NASA Johnson Space Center Usability Testing and Analysis Facility (WAF) Overview

    Science.gov (United States)

    Whitmore, M.

    2004-01-01

    The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility provides support to the Office of Biological and Physical Research, the Space Shuttle Program, the International Space Station Program, and other NASA organizations. In addition, there are ongoing collaborative research efforts with external businesses and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes. This presentation will provide an overview of ongoing activities, and will address how the projects will evolve to meet new space initiatives.

  17. Eddy current testing, volume 1

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1981-11-01

    This training and reference manual was assembled to provide those involved in eddy current testing with both the fundamental principles of the technique as well as the knowledge to deal with often complicated test results. A non-rigorous approach is used to simplify complex physical phenomena. Emphasis is placed on proper choice of test frequency and interpretation. Defect detection and diagnosis receive particular attention. Design and construction of probes are covered extensively since probes play a key role in eddy current testing. The advantages and limitations of various probe types are discussed. Electromagnetic theory, instrumentation, test methods and signal analysis are covered. Simplified derivations of probe response to test parameters are presented to develop a basic understanding of eddy current behaviour. Eddy current signals are presented on impedance plane diagrams throughout the manual since this is the most common display on modern, general purpose instruments. The use of 'phase leg' in signal analysis is covered in detail. To supplement theory, practical examples are presented to develop proficiency in performing inspections, and to illustrate how basic principles are applied to diagnose real signals

  18. High volume improves outcomes: The argument for centralization of rectal cancer surgery.

    Science.gov (United States)

    Aquina, Christopher T; Probst, Christian P; Becerra, Adan Z; Iannuzzi, James C; Kelly, Kristin N; Hensley, Bradley J; Rickles, Aaron S; Noyes, Katia; Fleming, Fergal J; Monson, John R T

    2016-03-01

    Centralization of care to "centers of excellence" in Europe has led to improved oncologic outcomes; however, little is known regarding the impact of nonmandated regionalization of rectal cancer care in the United States. The Statewide Planning and Research Cooperative System (SPARCS) was queried for elective abdominoperineal and low anterior resections for rectal cancer from 2000 to 2011 in New York with the use of International Classification of Diseases, Ninth Revision codes. Surgeon volume and hospital volume were grouped into quartiles, and high-volume surgeons (≥ 10 resections/year) and hospitals (≥ 25 resections/year) were defined as the top quartile of annual caseload of rectal cancer resection and compared with the bottom 3 quartiles during analyses. Bivariate and multilevel regression analyses were performed to assess factors associated with restorative procedures, 30-day mortality, and temporal trends in these endpoints. Among 7,798 rectal cancer resections, the overall rate of no-restorative proctectomy and 30-day mortality decreased by 7.7% and 1.2%, respectively, from 2000 to 2011. In addition, there was a linear increase in the proportion of cases performed by both high-volume surgeons and high-volume hospitals and a decrease in the number of surgeons and hospitals performing rectal cancer surgery. High-volume surgeons at high-volume hospitals were associated independently with both less nonrestorative proctectomies (odds ratio 0.65, 95% confidence interval 0.48-0.89) and mortality (odds ratio 0.43, 95% confidence interval 0.21-0.87) rates. No patterns of significant improvement within the volume strata of the surgeon and hospitals were observed over time. This study suggests that the current trend toward regionalization of rectal cancer care to high-volume surgeons and high-volume centers has led to improved outcomes. These findings have implications regarding the policy of health care delivery in the United States, supporting referral to high-volume

  19. 10 Years Later: Lessons Learned from an Academic Multidisciplinary Cosmetic Center.

    Science.gov (United States)

    Chen, Jenny T; Nayar, Harry S; Rao, Venkat K

    2017-09-01

    In 2006, a Centers for Medicare and Medicaid Services-accredited multidisciplinary academic ambulatory surgery center was established with the goal of delivering high-quality, efficient reconstructive, and cosmetic services in an academic setting. We review our decade-long experience since its establishment. Clinical and financial data from 2006 to 2016 are reviewed. All cosmetic procedures, including both minimally invasive and operative cases, are included. Data are compared to nationally published reports. Nearly 3,500 cosmetic surgeries and 10,000 minimally invasive procedures were performed. Compared with national averages, surgical volume in abdominoplasty is high, whereas rhinoplasty and breast augmentation is low. Regarding trend data, breast augmentation volume has decreased by 25%, whereas minimally invasive procedural volume continues to grow and is comparable with national reports. Similarly, where surgical revenue remains steady, minimally invasive revenue has increased significantly. The majority of surgical cases (70%) are reconstructive in nature and insurance-based. Payer mix is 71% private insurance, 18% Medicare and Medicaid, and 11% self-pay. Despite year-over-year revenue increases, net profit in 2015 was $6,120. Rent and anesthesia costs exceed national averages, and employee salary and wages are the highest expenditure. Although the creation of our academic cosmetic ambulatory surgery center has greatly increased the overall volume of cosmetic surgery performed at the University of Wisconsin, the majority of surgical volume and revenue is reconstructive. As is seen nationwide, minimally invasive cosmetic procedures represent our most rapidly expanding revenue stream.

  20. Testing the new ICRU 62 'Planning Organ at Risk Volume' concept for the rectum

    International Nuclear Information System (INIS)

    Muren, Ludvig Paul; Karlsdottir, Asa; Kvinnsland, Yngve; Wentzel-Larsen, Tore; Dahl, Olav

    2005-01-01

    Background and purpose: To study the impact of the new ICRU 62 'Planning organ at Risk Volume' (PRV) concept on the relationship between rectum dose-volume histogram (DVH) data and toxicity. Patients and methods: The acute gastro-intestinal (GI) RTOG toxicity in 127 prostate cancer patients prescribed a total dose of 70 Gy with conformal irradiation to either the prostate, the prostate and seminal vesicles or the whole pelvis (initial 50 Gy only) were analysed. DVHs were derived for the rectum only and for rectum extended with six PRV margin sets (narrow/intermediate/wide; anterior/anterior and posterior). The data was analysed using permutation tests, logistic regression and effective uniform dose (EUD) calculations. Results: Acute Grade 2 GI toxicity was seen in 22 of 127 cases (17%). Permutation tests showed that the difference between DVHs for patients with and without Grade 2 effects was significant, both for rectum only and rectum PRVs (P-value range: 0.02-0.04), with generally lower P-values for the PRVs. In the logistic regression, the fractional DVH variables (i.e. volumes) were significantly related to toxicity, with approximately 2-3 times as many significant dose levels for the PRVs as for rectum only. E.g. with wide anterior and posterior margins (16 and 11 mm, respectively) the relation was significant at 26 different dose levels (6-7, 13-14, 35-43, 60-71 and 73 Gy), compared to nine levels (38-40, 43-44 and 71-74 Gy) for rectum only. EUDs were significantly different for patients with and without Grade 2 effects both for rectum only and the PRVs (95% confidence interval for EUD increase with Grade 2 effects: 0.1-3.1 Gy). Conclusions: All statistical methods applied indicated a small, but definite difference in DVH parameters between patients with versus those without Grade 2 effects. The difference was most pronounced when margins of 16 mm anterior and 11 mm posterior were applied

  1. AHPCRC (Army High Performance Computing Research Center) Bulletin. Volume 1, Issue 2

    Science.gov (United States)

    2011-01-01

    area and the researchers working on these projects. Also inside: news from the AHPCRC consortium partners at Morgan State University and the NASA ...Computing Research Center is provided by the supercomputing and research facilities at Stanford University and at the NASA Ames Research Center at...atomic and molecular level, he said. He noted that “every general would like to have” a Star Trek -like holodeck, where holographic avatars could

  2. Adequacy of power-to-volume scaling philosophy to simulate natural circulation in Integral Test Facilities

    International Nuclear Information System (INIS)

    Nayak, A.K.; Vijayan, P.K.; Saha, D.; Venkat Raj, V.; Aritomi, Masanori

    1998-01-01

    Theoretical and experimental investigations were carried out to study the adequacy of power-to-volume scaling philosophy for the simulation of natural circulation and to establish the scaling philosophy applicable for the design of the Integral Test Facility (ITF-AHWR) for the Indian Advanced Heavy Water Reactor (AHWR). The results indicate that a reduction in the flow channel diameter of the scaled facility as required by the power-to-volume scaling philosophy may affect the simulation of natural circulation behaviour of the prototype plants. This is caused by the distortions due to the inability to simulate the frictional resistance of the scaled facility. Hence, it is recommended that the flow channel diameter of the scaled facility should be as close as possible to the prototype. This was verified by comparing the natural circulation behaviour of a prototype 220 MWe Indian PHWR and its scaled facility (FISBE-1) designed based on power-to-volume scaling philosophy. It is suggested from examinations using a mathematical model and a computer code that the FISBE-1 simulates the steady state and the general trend of transient natural circulation behaviour of the prototype reactor adequately. Finally the proposed scaling method was applied for the design of the ITF-AHWR. (author)

  3. Osmosis-induced water uptake by Eurobitum bituminized radioactive waste and pressure development in constant volume conditions

    International Nuclear Information System (INIS)

    Mariën, A.; Mokni, N.; Valcke, E.; Olivella, S.; Smets, S.; Li, X.

    2013-01-01

    Highlights: ► The water uptake by Eurobitum is studied to judge the safety of geological disposal. ► High pressures of up to 20 MPa are measured in constant volume water uptake tests. ► The morphology of leached Eurobitum samples is studied with μCT and ESEM. ► The observations are reproduced by an existing CHM formulation for Eurobitum. - Abstract: The chemo-hydro-mechanical (CHM) interaction between swelling Eurobitum radioactive bituminized waste (BW) and Boom Clay is investigated to assess the feasibility of geological disposal for the long-term management of this waste. These so-called compatibility studies include laboratory water uptake tests at Belgian Nuclear Research Center SCK-CEN, and the development of a coupled CHM formulation for Eurobitum by the International Center for Numerical Methods and Engineering (CIMNE, Polytechnical University of Cataluña, Spain). In the water uptake tests, the osmosis-induced swelling, pressure increase and NaNO 3 leaching of small cylindrical BW samples (diameter 38 mm, height 10 mm) is studied under constant total stress conditions and nearly constant volume conditions; the actual geological disposal conditions should be intermediate between these extremes. Two nearly constant volume tests were stopped after 1036 and 1555 days to characterize the morphology of the hydrated BW samples and to visualize the hydrated part with microfocus X-ray Computer Tomography (μCT) and Environmental Scanning Electron Microscopy (ESEM). In parallel, a coupled CHM formulation is developed that describes chemically and hydraulically coupled flow processes in porous materials with salt crystals, and that incorporates a porosity dependent membrane efficiency, permeability and diffusivity. When Eurobitum BW is hydrated in (nearly) constant volume conditions, the osmosis-induced water uptake results in an increasing pressure to values that can be (in theory) as high as 42.8 MPa, being the osmotic pressure of a saturated NaNO 3

  4. Barrier Island Dynamics Using Mass Center Analysis: A New Way to Detect and Track Large-Scale Change

    Directory of Open Access Journals (Sweden)

    Paul Paris

    2014-01-01

    Full Text Available A geographic information system (GIS was used to introduce and test a new method for quantitatively characterizing topographic change. Borrowing from classic Newtonian mechanics, the concept of a body’s center of mass is applied to the geomorphic landscape, and the barrier island environment in particular, to evaluate the metric’s potential as a proxy for detecting, tracking and visualizing change. Two barrier islands along North Carolina’s Outer Banks are used to test this idea: Core Banks, uninhabited and largely-undeveloped, and Hatteras Island, altered by the presence of a protective dune system. Findings indicate that for Core Banks, the alongshore change in the center of mass is in accord with dominate littoral transport and wind conditions. Cross-shore change agrees with independent estimates for the island migration rates. This lends credence to our assertion that the mass center metric has the potential to be a viable proxy for describing wholesale barrier migration and would be a valuable addition to the already-established ocean shoreline and subaerial volume metrics. More research is, however, required to demonstrate efficacy.

  5. LERF Basin 44 Process Test Plan

    International Nuclear Information System (INIS)

    LUECK, K.J.

    1999-01-01

    This document presents a plan to process a portion of the Liquid Effluent Retention Facility (LERF) Basin 44 wastewater through the 200 Area Effluent Treatment Facility (ETF). The objective of this process test is to determine the most effective/efficient method to treat the wastewater currently stored in LERF Basin 44. The process test will determine the operational parameters necessary to comply with facility effluent discharge permit limits (Ecology 1995) and the Environmental Restoration Disposal Facility (ERDF) acceptance criteria (BHI-00139), while achieving ALARA goals and maintaining the integrity of facility equipment. A major focus of the test plan centers on control of contamination due to leaks and/or facility maintenance. As a pre-startup item, all known leaks will be fixed before the start of the test. During the course of the test, a variety of contamination control measures will be evaluated for implementation during the treatment of the remaining Basin 44 inventory. Of special interest will be techniques and tools used to prevent contamination spread during sampling and when opening contaminated facility equipment/piping. At the conclusion of the test, a post ALARA review will be performed to identify lessons learned from the test run which can be applied to the treatment of the remaining Basin 44 inventory. The volume of wastewater to be treated during this test run is 500,000 gallons. This volume limit is necessary to maintain the ETF radiological inventory limits per the approved authorization basis. The duration of the process test is approximately 30 days

  6. Asset Analysis and Operational Concepts for Separation Assurance Flight Testing at Dryden Flight Research Center

    Science.gov (United States)

    Costa, Guillermo J.; Arteaga, Ricardo A.

    2011-01-01

    A preliminary survey of existing separation assurance and collision avoidance advancements, technologies, and efforts has been conducted in order to develop a concept of operations for flight testing autonomous separation assurance at Dryden Flight Research Center. This effort was part of the Unmanned Aerial Systems in the National Airspace System project. The survey focused primarily on separation assurance projects validated through flight testing (including lessons learned), however current forays into the field were also examined. Comparisons between current Dryden flight and range assets were conducted using House of Quality matrices in order to allow project management to make determinations regarding asset utilization for future flight tests. This was conducted in order to establish a body of knowledge of the current collision avoidance landscape, and thus focus Dryden s efforts more effectively towards the providing of assets and test ranges for future flight testing within this research field.

  7. Optical Interconnects for Future Data Center Networks

    CERN Document Server

    Bergman, Keren; Tomkos, Ioannis

    2013-01-01

    Optical Interconnects for Future Data Center Networks covers optical networks and how they can provide high bandwidth, energy efficient interconnects with increased communication bandwidth. This volume, with contributions from leading researchers in the field, presents an integrated view of the expected future requirements of data centers and serves as a reference for some of the most advanced and promising solutions proposed by researchers from leading universities, research labs, and companies. The work also includes several novel architectures, each demonstrating different technologies such as optical circuits, optical switching, MIMO optical OFDM, and others. Additionally, Optical Interconnects for Future Data Center Networks provides invaluable insights into the benefits and advantages of optical interconnects and how they can be a promising alternative for future data center networks.

  8. Optimization of the testing volumes with respect to neutron flux levels in the two-target high flux D-Li neutron source for the international fusion materials irradiation facility

    International Nuclear Information System (INIS)

    Kelleher, W.P.; Varsamis, G.L.

    1989-01-01

    An economic and fusion-relevant source of high-energy neutrons is an essential element in the fusion nuclear technology and development program. This source can be generated by directing a high energy deuteron beam onto a flowing liquid lithium target, producing neutrons via the D-Lithium stripping reaction. Previous work on this type of source concentrated on a design employing one deuteron beam of modest amperage. This design was shown to have a relatively small testing volume with high flux gradients and was therefor considered somewhat unattractive from a materials testing standpoint. A design using two lithium targets and two high-amperage beams has recently been proposed. This two beam design has been examined in an effort to maximize the test volume while minimizing the flux gradients and minimizing the effect of radiation damage on one target due to the other. A spatial, energy and angle dependent neutron source modeling the D-Lithium source was developed. Using this source, a 3-dimensional map of uncollided flux within the test volume was calculated. The results showed that the target separation has little effect on the available experimental volume and that a testing volume of ∼35 liters is available with a volume averaged flux above 10 14 n/cm 2 /s. The collided flux within the test volume was then determined by coupling the source model with a Monte Carlo code. The spectral effects of the high-energy tail in the flux were examined and evaluated as to possible effects on materials response. Calculations comparing the radiation damage to materials from the D-Lithium source to that cause by a standard DT fusion first-wall neutron flux spectrum showed that the number of appm and dpa, as well as the ratio appm/dpa and dpa/MW/m 2 are within 30% for the two sources. 8 refs., 8 figs

  9. Space and Earth Sciences, Computer Systems, and Scientific Data Analysis Support, Volume 1

    Science.gov (United States)

    Estes, Ronald H. (Editor)

    1993-01-01

    This Final Progress Report covers the specific technical activities of Hughes STX Corporation for the last contract triannual period of 1 June through 30 Sep. 1993, in support of assigned task activities at Goddard Space Flight Center (GSFC). It also provides a brief summary of work throughout the contract period of performance on each active task. Technical activity is presented in Volume 1, while financial and level-of-effort data is presented in Volume 2. Technical support was provided to all Division and Laboratories of Goddard's Space Sciences and Earth Sciences Directorates. Types of support include: scientific programming, systems programming, computer management, mission planning, scientific investigation, data analysis, data processing, data base creation and maintenance, instrumentation development, and management services. Mission and instruments supported include: ROSAT, Astro-D, BBXRT, XTE, AXAF, GRO, COBE, WIND, UIT, SMM, STIS, HEIDI, DE, URAP, CRRES, Voyagers, ISEE, San Marco, LAGEOS, TOPEX/Poseidon, Pioneer-Venus, Galileo, Cassini, Nimbus-7/TOMS, Meteor-3/TOMS, FIFE, BOREAS, TRMM, AVHRR, and Landsat. Accomplishments include: development of computing programs for mission science and data analysis, supercomputer applications support, computer network support, computational upgrades for data archival and analysis centers, end-to-end management for mission data flow, scientific modeling and results in the fields of space and Earth physics, planning and design of GSFC VO DAAC and VO IMS, fabrication, assembly, and testing of mission instrumentation, and design of mission operations center.

  10. Interrater reliability of the Volume-Viscosity Swallow Test; screening for dysphagia among hospitalized elderly medical patients

    DEFF Research Database (Denmark)

    Jørgensen, Lise Walther; Søndergaard, Kasper; Melgaard, Dorte

    2017-01-01

    Background: Oropharyngeal dysphagia (OD) is prevalent among medical and geriatric patients admitted due to acute illness and it is associated with malnutrition, increased length of stay and increased mortality. A valid and reliable bedside screening test for patients at risk of OD is essential...... in order to detect patients in need of further assessment. The Volume-Viscosity Swallow Test (V-VST) has been shown to be a valid screening test for OD in mixed outpatient populations. However, as reliability of the test has yet to be investigated in a population of medical and geriatric patients admitted...... skilled occupational therapists examined an unselected group of 110 patients admitted to geriatric or medical wards. In an overall agreement phase raters reached ≥80% agreement before data collection phase was commenced. The V-VST was applied to patients twice within maximum one hour by raters who...

  11. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.

    Science.gov (United States)

    Toyama, H; Endo, Y; Ejima, Y; Matsubara, M; Kurosawa, S

    2011-07-01

    In neonates, small changes in tidal volumes (V(T)) may lead to complications. Previous studies have shown a significant difference between ventilator-measured tidal volume and tidal volume delivered (actual V(T)). We evaluated the accuracy of three different ventilators to deliver small V(T) during volume-controlled ventilation. We tested Servo 300, 840 ventilator and Evita 4 Neoflow ventilators with lung models simulating normal and injured neonatal lung compliance models. Gas volume delivered from the ventilator into the test circuit (V(TV)) and actual V(T) to the test lung were measured using Ventrak respiration monitors at set V(T) (30 ml). The gas volume increase of the breathing circuit was then calculated. Tidal volumes of the SV300 and PB840 in both lung models were similar to the set V(T) and the actual tidal volumes in the injured model (20.7 ml and 19.8 ml, respectively) were significantly less than that in the normal model (27.4 ml and 23.4 ml). PB840 with circuit compliance compensation could not improve the actual V(T). V(TV) of the EV4N in the normal and the injured models (37.8 ml and 46.6 ml) were markedly increased compared with set V(T), and actual V(T) were similar to set V(T) in the normal and injured model (30.2 ml and 31.9 ml, respectively). EV4N measuring V(T) close to the lung could match actual V(T) to almost the same value as the set V(T) however the gas volume of the breathing circuit was increased. If an accurate value for the patient's actual V(T) is needed, this V(T) must be measured by a sensor located between the Y-piece and the tracheal tube.

  12. Guidelines for selecting codes for ground-water transport modeling of low-level waste burial sites. Volume 2. Special test cases

    International Nuclear Information System (INIS)

    Simmons, C.S.; Cole, C.R.

    1985-08-01

    This document was written for the National Low-Level Waste Management Program to provide guidance for managers and site operators who need to select ground-water transport codes for assessing shallow-land burial site performance. The guidance given in this report also serves the needs of applications-oriented users who work under the direction of a manager or site operator. The guidelines are published in two volumes designed to support the needs of users having different technical backgrounds. An executive summary, published separately, gives managers and site operators an overview of the main guideline report. Volume 1, titled ''Guideline Approach,'' consists of Chapters 1 through 5 and a glossary. Chapters 2 through 5 provide the more detailed discussions about the code selection approach. This volume, Volume 2, consists of four appendices reporting on the technical evaluation test cases designed to help verify the accuracy of ground-water transport codes. 20 refs

  13. 10 Years Later: Lessons Learned from an Academic Multidisciplinary Cosmetic Center

    Directory of Open Access Journals (Sweden)

    Jenny T. Chen, MD

    2017-09-01

    Conclusion:. Although the creation of our academic cosmetic ambulatory surgery center has greatly increased the overall volume of cosmetic surgery performed at the University of Wisconsin, the majority of surgical volume and revenue is reconstructive. As is seen nationwide, minimally invasive cosmetic procedures represent our most rapidly expanding revenue stream.

  14. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient....... There was a mean difference of 0.01 mm in MPT (limits of agreement: -0.45 to 0.42 mm, Pearson's correlation coefficient: 0.96). Both volume measurements exhibited high reproducibility, with PPV being superior (limits of agreement: -35.3 mm3to 33.5 mm3, Pearson's correlation coefficient: 0.96) to TPV (limits...... of agreement: -88.2 to 61.5 mm3, Pearson's correlation coefficient: 0.91). The good reproducibility revealed by the present results encourages future studies on establishing plaque quantification as part of cardiovascular risk assessment and for follow-up of disease progression over time....

  15. Temporal lobe volume predicts Wada memory test performance in patients with mesial temporal sclerosis.

    Science.gov (United States)

    Ding, Kan; Gong, Yunhua; Modur, Pradeep N; Diaz-Arrastia, Ramon; Agostini, Mark; Gupta, Puneet; McColl, Roderick; Hays, Ryan; Van Ness, Paul

    2016-02-01

    The Wada test is widely used in the presurgical evaluation of potential temporal lobectomy patients to predict postoperative memory function. Expected asymmetry (EA), defined as Wada memory lateralized to the nonsurgical hemisphere, or a higher score after injection of the surgical hemisphere would be considered favorable in terms of postoperative memory outcome. However, in some cases, nonlateralized memory (NM) results, with no appreciable asymmetry, may occur because of impaired scores after both injections, often leading to denial of surgery. The reason for such nonlateralized Wada memory in patients with intractable temporal lobe epilepsy (TLE) remains unclear. Given that quantitative morphometric magnetic resonance imaging studies in TLE patients have shown bilateral regional atrophy in temporal and extratemporal structures, we hypothesized that the volume loss in contralateral temporal structures could contribute to nonlateralized Wada memory performance. To investigate this, we examined the relationship between the volume changes of temporal structures and Wada memory scores in patients with intractable TLE with mesial temporal sclerosis (MTS) using an age- and gender-matched control group. Memory was considered nonlateralized if the absolute difference in the total correct recall scores between ipsilateral and contralateral injections was memory was lateralized in 15 and nonlateralized in 6 patients, with all the nonlateralized scores being observed in left TLE. The recall scores after ipsilateral injection were significantly lower in patients with an NM profile than an EA profile (23 ± 14% vs. 59 ± 18% correct recall, p ≤ 0.001). However, the recall scores after contralateral injection were low but similar between the two groups (25 ± 17% vs. 25 ± 15% correct recall, p=0.97). Compared to controls, all the patients showed greater volume loss in the temporal regions. However, patients with a NM profile showed significantly more volume loss than those

  16. Is orbital volume associated with eyeball and visual cortex volume in humans?

    Science.gov (United States)

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.

  17. SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Chetty, I [Henry Ford Health System, Detroit, MI (United States); Snyder, K [Henry Ford Hospital System, Detroit, MI (United States); Scheib, S [Varian Medical System, Barton (Switzerland); Qin, Y; Li, H [Henry Ford Health System, Detroit, Michigan (United States)

    2016-06-15

    Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL) tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American

  18. Building the Teraflops/Petabytes Production Computing Center

    International Nuclear Information System (INIS)

    Kramer, William T.C.; Lucas, Don; Simon, Horst D.

    1999-01-01

    In just one decade, the 1990s, supercomputer centers have undergone two fundamental transitions which require rethinking their operation and their role in high performance computing. The first transition in the early to mid-1990s resulted from a technology change in high performance computing architecture. Highly parallel distributed memory machines built from commodity parts increased the operational complexity of the supercomputer center, and required the introduction of intellectual services as equally important components of the center. The second transition is happening in the late 1990s as centers are introducing loosely coupled clusters of SMPs as their premier high performance computing platforms, while dealing with an ever-increasing volume of data. In addition, increasing network bandwidth enables new modes of use of a supercomputer center, in particular, computational grid applications. In this paper we describe what steps NERSC is taking to address these issues and stay at the leading edge of supercomputing centers.; N

  19. NASA Johnson Space Center Usability Testing and Analysis facility (UTAF) Overview

    Science.gov (United States)

    Whitmore, Mihriban; Holden, Kritina L.

    2005-01-01

    The Usability Testing and Analysis Facility (UTAF) is part of the Space Human Factors Laboratory at the NASA Johnson Space Center in Houston, Texas. The facility performs research for NASA's HumanSystems Integration Program, under the HumanSystems Research and Technology Division. Specifically, the UTAF provides human factors support for space vehicles, including the International Space Station, the Space Shuttle, and the forthcoming Crew Exploration Vehicle. In addition, there are ongoing collaborative research efforts with external corporations and universities. The UTAF provides human factors analysis, evaluation, and usability testing of crew interfaces for space applications. This includes computer displays and controls, workstation systems, and work environments. The UTAF has a unique mix of capabilities, with a staff experienced in both cognitive human factors and ergonomics. The current areas of focus are: human factors applications in emergency medical care and informatics; control and display technologies for electronic procedures and instructions; voice recognition in noisy environments; crew restraint design for unique microgravity workstations; and refinement of human factors processes and requirements. This presentation will provide an overview of ongoing activities, and will address how the UTAF projects will evolve to meet new space initiatives.

  20. Clinical utility of computed tomographic lung volumes in patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Lee, Jae Seung; Lee, Sang-Min; Seo, Joon Beom; Lee, Sei Won; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do

    2014-01-01

    Published data concerning the utility of computed tomography (CT)-based lung volumes are limited to correlation with lung function. The aim of this study was to evaluate the clinical utility of the CT expiratory-to-inspiratory lung volume ratio (CT Vratio) by assessing the relationship with clinically relevant outcomes. A total of 75 stable chronic obstructive pulmonary disease (COPD) patients having pulmonary function testing and volumetric CT at full inspiration and expiration were retrospectively evaluated. Inspiratory and expiratory CT lung volumes were measured using in-house software. Correlation of the CT Vratio with patient-centered outcomes, including the modified Medical Research Council (MMRC) dyspnea score, the 6-min walk distance (6MWD), the St. George's Respiratory Questionnaire (SGRQ) score, and multidimensional COPD severity indices, such as the BMI, airflow obstruction, dyspnea, and exercise capacity index (BODE) and age, dyspnea, and airflow obstruction (ADO), were analyzed. The CT Vratio correlated significantly with BMI (r = -0.528, p < 0.001). The CT Vratio was also significantly associated with MMRC dyspnea (r = 0.387, p = 0.001), 6MWD (r = -0.459, p < 0.001), and SGRQ (r = 0.369, p = 0.001) scores. Finally, the CT Vratio had significant correlations with the BODE and ADO multidimensional COPD severity indices (r = 0.605, p < 0.001; r = 0.411, p < 0.001). The CT Vratio had significant correlations with patient-centered outcomes and multidimensional COPD severity indices. © 2013 S. Karger AG, Basel.

  1. Component Fragility Research Program: Phase 1, Demonstration tests: Volume 1, Summary report

    International Nuclear Information System (INIS)

    Holman, G.S.; Chou, C.K.; Shipway, G.D.; Glozman, V.

    1987-08-01

    This report describes tests performed in Phase I of the NRC Component Fragility Research Program. The purpose of these tests was to demonstrate procedures for characterizing the seismic fragility of a selected component, investigating how various parameters affect fragility, and finally using test data to develop practical fragility descriptions suitable for application in probabilistic risk assessments. A three-column motor control center housing motor controllers of various types and sizes as well as relays of different types and manufacturers was subjected to seismic input motions up to 2.5g zero period acceleration. To investigate the effect of base flexibility on the structural behavior of the MCC and on the functional behavior of the electrical devices, multiple tests were performed on each of four mounting configurations: four bolts per column with top bracking, four bolts per column with no top brace, four bolts per column with internal diagonal bracking, and two bolts per column with no top or internal bracking. Device fragility was characterized by contact chatter correlated to local in-cabinet response at the device location. Seismic capacities were developed for each device on the basis of local input motion required to cause chatter; these results were then applied to develop probabilistic fragility curves for each type of device, including estimates of the ''high-confidence low probability of failure'' capacity of each

  2. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania.

    Science.gov (United States)

    Coyle, Catelyn; Kwakwa, Helena

    2016-01-01

    Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012-August 31, 2013) and after (September 1, 2013-May 31, 2014) implementation of the dual-routine HCV/HIV testing model. A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening

  3. The Space Operations Simulation Center (SOSC) and Closed-Loop Hardware Testing for Orion Rendezvous System Design

    Science.gov (United States)

    Milenkovic, Zoran; DSouza, Christopher; Huish, David; Bendle, John; Kibler, Angela

    2012-01-01

    The exploration goals of Orion / MPCV Project will require a mature Rendezvous, Proximity Operations and Docking (RPOD) capability. Ground testing autonomous docking with a next-generation sensor such as the Vision Navigation Sensor (VNS) is a critical step along the path of ensuring successful execution of autonomous RPOD for Orion. This paper will discuss the testing rationale, the test configuration, the test limitations and the results obtained from tests that have been performed at the Lockheed Martin Space Operations Simulation Center (SOSC) to evaluate and mature the Orion RPOD system. We will show that these tests have greatly increased the confidence in the maturity of the Orion RPOD design, reduced some of the latent risks and in doing so validated the design philosophy of the Orion RPOD system. This paper is organized as follows: first, the objectives of the test are given. Descriptions of the SOSC facility, and the Orion RPOD system and associated components follow. The details of the test configuration of the components in question are presented prior to discussing preliminary results of the tests. The paper concludes with closing comments.

  4. Relation Between Pressure and Volume Unloading During Ramp Testing in Patients Supported with a Continuous-Flow Left Ventricular Assist Device

    DEFF Research Database (Denmark)

    Jung, Mette H; Hassager, Christian; Balling, Louise

    2015-01-01

    Pulmonary capillary wedge pressure (PCWP) is the key to describing left ventricular (LV) unloading, however, the relation between pressure and the echocardiography-derived surrogate of LV volume (left ventricular end-diastolic diameter (LVEDD)) as a function of pump speed (RPM) in continuous......-flow left ventricular assist device (CF-LVAD) patients is unknown. In this study the pressure-volume relationship as a function of RPM during ramp testing was investigated by simultaneously measuring PCWP by Swan-Ganz catheter and LVEDD by echocardiography. The ramp protocol started at usual pump setting...

  5. PULSE COMBUSTOR DESIGN QUALIFICATION TEST AND CLEAN COAL FEEDSTOCK TEST - VOLUME I AND VOLUME II

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-02-08

    For this Cooperative Agreement, the pulse heater module is the technology envelope for an indirectly heated steam reformer. The field of use of the steam reformer pursuant to this Cooperative Agreement with DOE is for the processing of sub-bituminous coals and lignite. The main focus is the mild gasification of such coals for the generation of both fuel gas and char--for the steel industry is the main focus. An alternate market application for the substitution of metallurgical coke is also presented. This project was devoted to qualification of a 253-tube pulse heater module. This module was designed, fabricated, installed, instrumented and tested in a fluidized bed test facility. Several test campaigns were conducted. This larger heater is a 3.5 times scale-up of the previous pulse heaters that had 72 tubes each. The smaller heater has been part of previous pilot field testing of the steam reformer at New Bern, North Carolina. The project also included collection and reduction of mild gasification process data from operation of the process development unit (PDU). The operation of the PDU was aimed at conditions required to produce char (and gas) for the Northshore Steel Operations. Northshore Steel supplied the coal for the process unit tests.

  6. Recycle operations as a methodology for radioactive waste volume reduction

    International Nuclear Information System (INIS)

    Rasmussen, G.A.

    1985-01-01

    The costs for packaging, transportation and burial of low-level radioactive metallic waste have become so expensive that an alternate method of decontamination for volume reduction prior to disposal can now be justified. The operation of a large-scale centralized recycle center for decontamination of selected low level radioactive waste has been proven to be an effective method for waste volume reduction and for retrieving valuable materials for unlimited use. The centralized recycle center concept allows application of state-of-the-art decontamination technology resulting in a reduction in utility disposal costs and a reduction in overall net amount of material being buried. Examples of specific decontamination process activities at the centralized facility will be reviewed along with a discussion of the economic impact of decontamination for recycling and volume reduction. Based on almost two years of operation of a centralized decontamination facility, a demonstrated capability exists. The concept has been cost effective and proves that valuable resources can be recycled

  7. SLRV Engineering Tests at Department of Transportation, Transportation Test Center : Volume 4. Data Logs.

    Science.gov (United States)

    1979-02-01

    The SLRV (Standard Light Rail Vehicle) is a 71-foot vehicle, articulated to negotiate curves down to a 32-foot radius and designed to operate at speeds up to 50 mph. Although the basic configuration and performance is standardized, the current operat...

  8. Building an imaging center: laying the foundation.

    Science.gov (United States)

    Foreman, M Shane; Geise, Jon D; Reed, Mary A

    2005-01-01

    In Spring 2003, Central Louisiana Imaging, Inc. (CLII), an 11-member radiology group, decided to create a properly configured freestanding imaging center. Before moving forward with the project, CLII conducted extensive market research and learned the following: CLII's ability to draw patients from a broad geography (central Louisiana) would work in its favor While the defined market was shrinking slightly and made up of middle-income households, the population was fairly well insured and aging at a rate comparable to the nation. Given an aging population and advances in technology, market demand for imaging was projected to grow despite the shrinking population. There were opportunities to differentiate on quality technology, service offering, and customer service; the sophistication and positioning of competitors is more important than the sheer number of competitors. CLII's relationship with key referring physicians was likely portable and would translate into volume within the new center. The group measured each potential service or modality against 5 evaluation criteria to determine whether a market opportunity existed: demographic fit, projected market demand, competitive positioning, "anchor service," and synergy with CLII's strategy. Once the market opportunity was confirmed and the service offering was set, CLII completed a 5-year proforma in order to project cash flows, capital costs, and the anticipated return on investment. CLII opened the imaging center in September 2004. Ten months into opeations, the center was a measurable success. The levels, and break-even by month 4, volumes are currently at year 2 levels, and the center recently added nuclear medicine and its second magnetic resonance imaging system-11 months ahead of schedule.

  9. Can We Train Military Surgeons in a Civilian Trauma Center?

    Science.gov (United States)

    Uchino, H; Kong, V Y; Oosthuizen, G V; Bruce, J L; Bekker, W; Laing, G L; Clarke, D L

    2018-01-01

    The objective of this study was to review the trauma workload and operative exposure in a major South African trauma center and provide a comparison with contemporary experience from major military conflict. All patients admitted to the PMTS following trauma were identified from the HEMR. Basic demographic data including mechanism of injury and body region injured were reviewed. All operative procedures were categorized. The total operative volume was compared with those available from contemporary literature documenting experience from military conflict in Afghanistan. Operative volume was converted to number of cases per year for comparison. During the 4-year study period, 11,548 patients were admitted to our trauma center. Eighty-four percent were male and the mean age was 29 years. There were 4974 cases of penetrating trauma, of which 3820 (77%) were stab wounds (SWs), 1006 (20%) gunshot wounds (GSWs) and the remaining 148 (3%) were animal injuries. There were 6574 cases of blunt trauma. The mechanism of injuries was as follows: assaults 2956, road traffic accidents 2674, falls 664, hangings 67, animal injuries 42, sports injury 29 and other injuries 142. A total of 4207 operations were performed. The volumes per year were equivalent to those reported from the military surgical literature. South Africa has sufficient burden of trauma to train combat surgeons. Each index case as identified from the military surgery literature has a sufficient volume in our center. Based on our work load, a 6-month rotation should be sufficient to provide exposure to almost all the major traumatic conditions likely to be encountered on the modern battlefield.

  10. NASA Aerospace Flight Battery Program: Wet Life of Nickel-Hydrogen (Ni-H2) Batteries. Volume 2, Part 3; Appendices

    Science.gov (United States)

    Jung, David S,; Lee, Leonine S.; Manzo, Michelle A.

    2010-01-01

    This NASA Aerospace Flight Battery Systems Working Group was chartered within the NASA Engineering and Safety Center (NESC). The Battery Working Group was tasked to complete tasks and to propose proactive work to address battery related, agency-wide issues on an annual basis. In its first year of operation, this proactive program addressed various aspects of the validation and verification of aerospace battery systems for NASA missions. Studies were performed, issues were discussed and in many cases, test programs were executed to generate recommendations and guidelines to reduce risk associated with various aspects of implementing battery technology in the aerospace industry. This document contains Part 3 - Volume II Appendices to Part 3 - Volume I.

  11. Worldwide electricity used in data centers

    International Nuclear Information System (INIS)

    Koomey, Jonathan G

    2008-01-01

    The direct electricity used by data centers has become an important issue in recent years as demands for new Internet services (such as search, music downloads, video-on-demand, social networking, and telephony) have become more widespread. This study estimates historical electricity used by data centers worldwide and regionally on the basis of more detailed data than were available for previous assessments, including electricity used by servers, data center communications, and storage equipment. Aggregate electricity use for data centers doubled worldwide from 2000 to 2005. Three quarters of this growth was the result of growth in the number of the least expensive (volume) servers. Data center communications and storage equipment each contributed about 10% of the growth. Total electricity use grew at an average annual rate of 16.7% per year, with the Asia Pacific region (without Japan) being the only major world region with growth significantly exceeding that average. Direct electricity used by information technology equipment in data centers represented about 0.5% of total world electricity consumption in 2005. When electricity for cooling and power distribution is included, that figure is about 1%. Worldwide data center power demand in 2005 was equivalent (in capacity terms) to about seventeen 1000 MW power plants.

  12. Worldwide electricity used in data centers

    Science.gov (United States)

    Koomey, Jonathan G.

    2008-07-01

    The direct electricity used by data centers has become an important issue in recent years as demands for new Internet services (such as search, music downloads, video-on-demand, social networking, and telephony) have become more widespread. This study estimates historical electricity used by data centers worldwide and regionally on the basis of more detailed data than were available for previous assessments, including electricity used by servers, data center communications, and storage equipment. Aggregate electricity use for data centers doubled worldwide from 2000 to 2005. Three quarters of this growth was the result of growth in the number of the least expensive (volume) servers. Data center communications and storage equipment each contributed about 10% of the growth. Total electricity use grew at an average annual rate of 16.7% per year, with the Asia Pacific region (without Japan) being the only major world region with growth significantly exceeding that average. Direct electricity used by information technology equipment in data centers represented about 0.5% of total world electricity consumption in 2005. When electricity for cooling and power distribution is included, that figure is about 1%. Worldwide data center power demand in 2005 was equivalent (in capacity terms) to about seventeen 1000 MW power plants.

  13. Business of Nuclear Safety Analysis Office, Nuclear Technology Test Center

    International Nuclear Information System (INIS)

    Hayakawa, Masahiko

    1981-01-01

    The Nuclear Technology Test Center established the Nuclear Safety Analysis Office to execute newly the works concerning nuclear safety analysis in addition to the works related to the proving tests of nuclear machinery and equipments. The regulations for the Nuclear Safety Analysis Office concerning its organization, business and others were specially decided, and it started the business formally in August, 1980. It is a most important subject to secure the safety of nuclear facilities in nuclear fuel cycle as the premise of developing atomic energy. In Japan, the strict regulation of safety is executed by the government at each stage of the installation, construction, operation and maintenance of nuclear facilities, based on the responsibility for the security of installers themselves. The Nuclear Safety Analysis Office was established as the special organ to help the safety examination related to the installation of nuclear power stations and others by the government. It improves and puts in order the safety analysis codes required for the cross checking in the safety examination, and carries out safety analysis calculation. It is operated by the cooperation of the Science and Technology Agency and the Agency of Natural Resources and Energy. The purpose of establishment, the operation and the business of the Nuclear Safety Analysis Office, the plan of improving and putting in order of analysis codes, and the state of the similar organs in foreign countries are described. (Kako, I.)

  14. Left ventricular volume measurements with free breathing respiratory self-gated 3-dimensional golden angle radial whole-heart cine imaging - Feasibility and reproducibility.

    Science.gov (United States)

    Holst, Karen; Ugander, Martin; Sigfridsson, Andreas

    2017-11-01

    To develop and evaluate a free breathing respiratory self-gated isotropic resolution technique for left ventricular (LV) volume measurements. A 3D radial trajectory with double golden-angle ordering was used for free-running data acquisition during free breathing in 9 healthy volunteers. A respiratory self-gating signal was extracted from the center of k-space and used with the electrocardiogram to bin all data into 3 respiratory and 25 cardiac phases. 3D image volumes were reconstructed and the LV endocardial border was segmented. LV volume measurements and reproducibility from 3D free breathing cine were compared to conventional 2D breath-held cine. No difference was found between 3D free breathing cine and 2D breath-held cine with regards to LV ejection fraction, stroke volume, end-systolic volume and end-diastolic volume (Pcine and 2D breath-held cine (Pcine and conventional 2D breath-held cine showed similar values and test-retest repeatability for LV volumes in healthy volunteers. 3D free breathing cine enabled retrospective sorting and arbitrary angulation of isotropic data, and could correctly measure LV volumes during free breathing acquisition. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Major-element geochemistry of the Silent Canyon--Black Mountain peralkaline volcanic centers, northwestern Nevada Test Site: applications to an assessment of renewed volcanism

    International Nuclear Information System (INIS)

    Crowe, B.M.; Sargent, K.A.

    1979-01-01

    The Silent Canyon and Black Mountain volcanic centers are located in the northern part of the Nevada Test Site. The Silent Canyon volcanic center is a buried cauldron complex of Miocene age (13 to 15 m.y.). Black Mountain volcanic center is an elliptical-shaped cauldron complex of late Miocene age. The lavas and tuffs of the two centers comprise a subalkaline-peralkaline association. Rock types range from quartz normative subalkaline trachyte and rhyolite to peralkaline commendite. The Gold Flat Member of the Thirsty Canyon Tuff (Black Mountain) is a pantellerite. The major-element geochemistry of the Black Mountain--Silent Canyon volcanic centers differ in the total range and distribution of SiO 2 , contents, the degree of peralkalinity (molecular Na 2 O + K 2 O > Al 2 O 3 ) and in the values of total iron and alumina through the range of rock types. These differences indicate that the suites were unrelated and evolved from differing magma bodies. The Black Mountain volcanic cycle represents a renewed phase of volcanism following cessation of the Timber Mountain--Silent Canyon volcanic cycles. Consequently, there is a small but numerically incalculable probability of recurrence of Black Mountain-type volcanism within the Nevada Test Site region. This represents a potential risk with respect to deep geologic storage of high-level radioactive waste at the Nevada Test Site

  16. A Guide to the Data Resources of the Henry A. Murray Research Center of Radcliffe College: A Center for the Study of Lives [and] Index to [the] Guide.

    Science.gov (United States)

    Radcliffe Coll., Cambridge, MA. Henry A. Murray Research Center.

    The first of two volumes provides information about data resources available at the Henry A. Murray Research Center of Radcliffe College, a multidisciplinary research center that is a national repository for social and behavioral science data on human development and social change; topics of special concern to women are collection priorities. The…

  17. Test of Effective Solid Angle code for the efficiency calculation of volume source

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M. Y.; Kim, J. H.; Choi, H. D. [Seoul National Univ., Seoul (Korea, Republic of); Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is hard to determine a full energy (FE) absorption peak efficiency curve for an arbitrary volume source by experiment. That's why the simulation and semi-empirical methods have been preferred so far, and many works have progressed in various ways. Moens et al. determined the concept of effective solid angle by considering an attenuation effect of γ-rays in source, media and detector. This concept is based on a semi-empirical method. An Effective Solid Angle code (ESA code) has been developed for years by the Applied Nuclear Physics Group in Seoul National University. ESA code converts an experimental FE efficiency curve determined by using a standard point source to that for a volume source. To test the performance of ESA Code, we measured the point standard sources and voluminous certified reference material (CRM) sources of γ-ray, and compared with efficiency curves obtained in this study. 200∼1500 KeV energy region is fitted well. NIST X-ray mass attenuation coefficient data is used currently to check for the effect of linear attenuation only. We will use the interaction cross-section data obtained from XCOM code to check the each contributing factor like photoelectric effect, incoherent scattering and coherent scattering in the future. In order to minimize the calculation time and code simplification, optimization of algorithm is needed.

  18. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  19. Bragg superlattice for obtaining individual photoluminescence of diamond color centers in dense 3D ensembles

    Science.gov (United States)

    Kukushkin, V. A.

    2017-10-01

    A way to significantly increase the spatial resolution of the color center photoluminescence collection in chemically vapor-deposited (CVD) diamond at a fixed exciting beam focal volume is suggested. It is based on the creation of a narrow waveguide for the color center photoluminescence with a small number of allowed vertical indices of guided modes. The waveguide is formed between the top surface of a CVD diamond film and an underlaid mirror—a Bragg superlattice made of interchanging high- and low boron-doped layers of CVD diamond. The guided color center photoluminescence is extracted through the top surface of a CVD diamond film with the frustrated total internal reflection method. According to the results of simulation made for a case when color centers are nitrogen-vacancy (NV) centers, the suggested way allows to increase the maximal value of the NV center concentration still compatible with selective collection of their photoluminescence by several times at a fixed exciting beam focal volume. This increase is provided without the deterioration of the NV center photoluminescence collection efficiency.

  20. Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, B.J.; Sullivan, S.G.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States)

    1994-01-01

    Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE`s Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from proceedings of technical meetings, journals, research reports, searches of the DOE Energy, Science and Technology Database (in general, the citation and abstract information is presented as obtained from this database), and reprints of published articles provided by the authors. Facility types and activities covered in the scope of this report include: radioactive waste, uranium enrichment, fuel fabrication, spent fuel storage and reprocessing, facility decommissioning, hot laboratories, tritium production, research, test and production reactors, weapons fabrication and testing, fusion, uranium and plutonium processing, radiography, and accelerators. Information on improved shielding design, decontamination, containments, robotics, source prevention and control, job planning, improved operational and design techniques, as well as on other topics, has been included. In addition, DOE/EH reports not included in previous volumes of the bibliography are in this volume (abstracts 611 to 684). This volume (Volume 5 of the series) contains 217 abstracts.

  1. Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5

    International Nuclear Information System (INIS)

    Dionne, B.J.; Sullivan, S.G.; Baum, J.W.

    1994-01-01

    Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE's Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from proceedings of technical meetings, journals, research reports, searches of the DOE Energy, Science and Technology Database (in general, the citation and abstract information is presented as obtained from this database), and reprints of published articles provided by the authors. Facility types and activities covered in the scope of this report include: radioactive waste, uranium enrichment, fuel fabrication, spent fuel storage and reprocessing, facility decommissioning, hot laboratories, tritium production, research, test and production reactors, weapons fabrication and testing, fusion, uranium and plutonium processing, radiography, and accelerators. Information on improved shielding design, decontamination, containments, robotics, source prevention and control, job planning, improved operational and design techniques, as well as on other topics, has been included. In addition, DOE/EH reports not included in previous volumes of the bibliography are in this volume (abstracts 611 to 684). This volume (Volume 5 of the series) contains 217 abstracts

  2. Glass-surface area to solution-volume ratio and its implications to accelerated leach testing

    International Nuclear Information System (INIS)

    Pederson, L.R.; Buckwalter, C.Q.; McVay, G.L.; Riddle, B.L.

    1982-10-01

    The value of glass surface area to solution volume ratio (SA/V) can strongly influence the leaching rate of PNL 76-68 glass. The leaching rate is largely governed by silicon solubility constraints. Silicic acid in solution reduced the elemental release of all glass components. No components are leached to depths greater than that of silicon. The presence of the reaction layer had no measurable effect on the rate of leaching. Accelerated leach testing is possible since PNL 76-68 glass leaching is solubility-controlled (except at very low SA/V values). A series of glasses leached with SA/V x time = constant will yield identical elemental release

  3. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  4. Information Retrieval Methods in Libraries and Information Centers ...

    African Journals Online (AJOL)

    The volumes of information created, generated and stored are immense that without adequate knowledge of information retrieval methods, the retrieval process for an information user would be cumbersome and frustrating. Studies have further revealed that information retrieval methods are essential in information centers ...

  5. The impact of preload reduction with head-up tilt testing on longitudinal and transverse left ventricular mechanics: a study utilizing deformation volume analysis.

    Science.gov (United States)

    Schneider, Caroline; Forsythe, Lynsey; Somauroo, John; George, Keith; Oxborough, David

    2018-03-01

    Left ventricular (LV) function is dependent on load, intrinsic contractility and relaxation with a variable impact on specific mechanics. Strain (ε) imaging allows the assessment of cardiac function; however, the direct relationship between volume and strain is currently unknown. The aim of this study was to establish the impact of preload reduction through head-up tilt (HUT) testing on simultaneous left ventricular (LV) longitudinal and transverse function and their respective contribution to volume change. A focused transthoracic echocardiogram was performed on 10 healthy male participants (23 ± 3 years) in the supine position and following 1 min and 5 min of HUT testing. Raw temporal longitudinal ε (Ls) and transverse ε (Ts) values were exported and divided into 5% increments across the cardiac cycle and corresponding LV volumes were traced at each 5% increment. This provided simultaneous LV longitudinal and transverse ε and volume loops (deformation volume analysis - DVA). There was a leftward shift of the ε-volume loop from supine to 1 min and 5 min of HUT ( P  transverse thickening from supine to 1 min, which was further augmented at 5 min ( P  = 0.018). Preload reduction occurs within 1 min of HUT but does not further reduce at 5 min. This decline is associated with a decrease in longitudinal ε and concomitant increase in transverse ε. Consequently, augmented transverse relaxation appears to be an important factor in the maintenance of LV filling in the setting of reduced preload. DVA provides information on the relative contribution of mechanics to a change in LV volume and may have a role in the assessment of clinical populations. © 2018 The authors.

  6. AJER VOLUME II-JULY 2014

    African Journals Online (AJOL)

    user

    African Journal of Economic Review, Volume 1I, Issue 2, July 2014 ..... This paper also carries out the Chow-break point test (stability test) to test .... Unlike other East African countries, Rwanda has had a lot of political instabilities characterized.

  7. Test of sup 3 He-based neutron polarizers at NIST

    CERN Document Server

    Jones, G L; Thompson, A K; Chowdhuri, Z; Dewey, M S; Snow, W M; Wietfeldt, F E

    2000-01-01

    Neutron spin filters based on polarized sup 3 He are useful over a wide neutron energy range and have a large angular acceptance among other advantages. Two optical pumping methods, spin-exchange and metastability-exchange, can produce the volume of highly polarized sup 3 He gas required for such neutron spin filters. We report a test of polarizers based on each of these two methods on a new cold, monochromatic neutron beam line at the NIST Center for Neutron Research.

  8. The Savannah River Technology Center environmental monitoring field test platform

    International Nuclear Information System (INIS)

    Rossabi, J.

    1993-01-01

    Nearly all industrial facilities have been responsible for introducing synthetic chemicals into the environment. The Savannah River Site is no exception. Several areas at the site have been contaminated by chlorinated volatile organic chemicals. Because of the persistence and refractory nature of these contaminants, a complete clean up of the site will take many years. A major focus of the mission of the Environmental Sciences Section of the Savannah River Technology Center is to develop better, faster, and less expensive methods for characterizing, monitoring, and remediating the subsurface. These new methods can then be applied directly at the Savannah River Site and at other contaminated areas in the United States and throughout the world. The Environmental Sciences Section has hosted field testing of many different monitoring technologies over the past two years primarily as a result of the Integrated Demonstration Program sponsored by the Department of Energy's Office of Technology Development. This paper provides an overview of some of the technologies that have been demonstrated at the site and briefly discusses the applicability of these techniques

  9. Volume of hydration in terminal cancer patients.

    Science.gov (United States)

    Bruera, E; Belzile, M; Watanabe, S; Fainsinger, R L

    1996-03-01

    In this retrospective study we reviewed the volume and modality of hydration of consecutive series of terminal cancer patients in two different settings. In a palliative care unit 203/290 admitted patients received subcutaneous hydration for 12 +/- 8 days at a daily volume of 1015 +/- 135 ml/day. At the cancer center, 30 consecutive similar patients received intravenous hydration for 11.5 +/- 5 days (P > 0.2) but at a daily volume of 2080 +/- 720 ml/day (P palliative care unit patients required discontinuation of hydration because of complications. Hypodermoclysis was administered mainly as a continuous infusion, an overnight infusion, or in one to three 1-h boluses in 62 (31%), 98 (48%) and 43 (21%) patients, respectively. Our findings suggest that, in some settings, patients may be receiving excessive volumes of hydration by less comfortable routes such as the intravenous route. Increased education and research in this area are badly needed.

  10. Radiographic determination of urinary bladder volume and residual urine volume

    International Nuclear Information System (INIS)

    Klumair, J.

    1977-01-01

    In the course of a long study the author has tested most of the methods for determination of urinary bladder volume. A radiographic method which can state bladder volume exactly in cc's is attainable only with great time and effort. In the author's experience, however, it is possible, by means of a pattern in connection with a IVP, to estimate residual urine volume from a post-void picture of the bladder with sufficient accuracy for practical purposes. An account is given of the production of this pattern and of two relatively simple calculations for residual volume based on AP and lateral views of circular- and ellipsoid-shaped bladders. Also discussed is the radiation exposure which varies with the radiographic methods used. In male patients, the radiation exposure appears to be negligible, especially when the testicles are protected by a radiation shield. In female patients - which make up only a small fraction of all patients -, radiation exposure is higher but must be accepted. (orig./MG) [de

  11. Nuclear Fuel Recovery and Recycling Center. License application, PSAR, volume 1

    International Nuclear Information System (INIS)

    1976-01-01

    A summary of the location and major design features of the proposed Nuclear Fuel Recovery and Recycling Center is presented. The safety aspects of the proposed facilities and operations are summarized, taking into account possible normal and abnormal operating and environmental conditions. A chapter on site characteristics is included

  12. International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST): Volume 2: Cases E300-E545.

    Energy Technology Data Exchange (ETDEWEB)

    Neymark J.; Judkoff, R.

    2004-12-01

    This report documents an additional set of mechanical system test cases that are planned for inclusion in ANSI/ASHRAE STANDARD 140. The cases test a program's modeling capabilities on the working-fluid side of the coil, but in an hourly dynamic context over an expanded range of performance conditions. These cases help to scale the significance of disagreements that are less obvious in the steady-state cases. The report is Vol. 2 of HVAC BESTEST Volume 1. Volume 1 was limited to steady-state test cases that could be solved with analytical solutions. Volume 2 includes hourly dynamic effects, and other cases that cannot be solved analytically. NREL conducted this work in collaboration with the Tool Evaluation and Improvement Experts Group under the International Energy Agency (IEA) Solar Heating and Cooling Programme Task 22.

  13. A Unique Outside Neutron and Gamma Ray Instrumentation Development Test Facility at NASA's Goddard Space Flight Center

    Science.gov (United States)

    Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Parsons, A.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    An outside neutron and gamma ray instrumentation test facility has been constructed at NASA's Goddard Space Flight Center (GSFC) to evaluate conceptual designs of gamma ray and neutron systems that we intend to propose for future planetary lander and rover missions. We will describe this test facility and its current capabilities for operation of planetary in situ instrumentation, utilizing a l4 MeV pulsed neutron generator as the gamma ray excitation source with gamma ray and neutron detectors, in an open field with the ability to remotely monitor and operate experiments from a safe distance at an on-site building. The advantage of a permanent test facility with the ability to operate a neutron generator outside and the flexibility to modify testing configurations is essential for efficient testing of this type of technology. Until now, there have been no outdoor test facilities for realistically testing neutron and gamma ray instruments planned for solar system exploration

  14. In-situ load-deformation characterization of the CSM/OCRD jointed test block

    International Nuclear Information System (INIS)

    Richardson, A.M.; Hustrulid, W.; Brown, S.; Ubbes, W.

    1985-01-01

    An extensive ambient-temperature test series has recently been completed on a block of Precambrian Gneiss at the Colorado School of Mines (CSM) Experimental Mine in Idaho Springs, Colorado. Block tests came into existence out of a desire to test a relatively large volume of rock and thereby minimize the scaling problems encountered when laboratory test results are used to obtain modeling parameters for full-size structures. A typical block test involves isolation of a large, approximately two-meter cube of rock by cutting slots on four sides and inserting flatjacks for loading. Much interest has recently centered around block tests as a promising method for in-situ characterization of rock-masses for licensing future commercial nuclear-waste repositories in crystalline rock. To date only a few block tests have been conducted

  15. Residual strength and crack propagation tests on C-130 airplane center wings with service-imposed fatigue damage

    Science.gov (United States)

    Snider, H. L.; Reeder, F. L.; Dirkin, W. J.

    1972-01-01

    Fourteen C-130 airplane center wings, each containing service-imposed fatigue damage resulting from 4000 to 13,000 accumulated flight hours, were tested to determine their fatigue crack propagation and static residual strength characteristics. Eight wings were subjected to a two-step constant amplitude fatigue test prior to static testing. Cracks up to 30 inches long were generated in these tests. Residual static strengths of these wings ranged from 56 to 87 percent of limit load. The remaining six wings containing cracks up to 4 inches long were statically tested as received from field service. Residual static strengths of these wings ranged from 98 to 117 percent of limit load. Damage-tolerant structural design features such as fastener holes, stringers, doublers around door cutouts, and spanwise panel splices proved to be effective in retarding crack propagation.

  16. Role of Ultrasound Volume Measurements of Testes in Evaluation of Infertile Men with Azoospermia

    International Nuclear Information System (INIS)

    Moon, Min Hoan; Sung, Chang Kyu; Cho, Jeong Yeon; Kim, Seung Hyup; Seo, Ju Tae; Chun, Yi Keong

    2012-01-01

    The purpose of our study was to assess the usefulness of ultrasound determined testicular volume in the evaluation of the infertile men with azoospermia. A computerized search from October 2005 to June 2010 generated a list of 45 infertile men with azoospermia (mean age, 34 years: age range, 26-44 years) who underwent both scrotal ultrasound and testis biopsy. Ultrasound determined testicular volumes were compared between infertile men with obstructive azoospermia and those with non-obstructive azoospermia. Testicular volume for obstructive azoospermia ranged from 6.4 ml to 26.9 ml, with a median volume of 14.0 ml. This volume was significantly larger than that of those with non-obstructive azoospermia, which ranged from 1.0 ml to 12.8 ml, with a median volume of 6.1 ml (p < 0.001). The area under the ROC curve for distinguishing non-obstructive azoospermia from obstructive azoospermia using testicular volume was 0.91. A cutoff value of less than or equal to 11.4 ml could distinguish non-obstructive azoospermia from obstructive azoospermia, with a sensitivity of 94.1% (95% CI; 71.3-99.9%) and a specificity of 73.3% (95% CI; 54.1-87.7%). Ultrasound-determined testicular volume can be helpful in the differentiation of obstructive azoospermia from non-obstructive azoospermia

  17. Mean corpuscular volume of control red blood cells determines the interpretation of eosin-5'-maleimide (EMA) test result in infants aged less than 6 months.

    Science.gov (United States)

    Ciepiela, Olga; Adamowicz-Salach, Anna; Bystrzycka, Weronika; Łukasik, Jan; Kotuła, Iwona

    2015-08-01

    Eosin-5'-maleimide (EMA) binding test is a flow cytometric test used to detect hereditary spherocytosis (HS). To perform the test sample from patients, 5-6 reference samples of red blood are needed. Our aim was to investigate how the mean corpuscular volume (MCV) of red blood cells influences on the value of fluorescence of bounded EMA dye and how the choice of reference samples affects the test result. EMA test was performed in peripheral blood from 404 individuals, including 31 children suffering from HS. Mean fluorescence channel of EMA-RBCs was measured with Cytomics FC500 flow cytometer. Mean corpuscular volume of RBCs was assessed with LH750 Beckman Coulter. Statistical analysis was performed using Graph Pad Prism. The correlation Spearman coefficient between mean channel of fluorescence of EMA-RBCs and MCV was r = 0.39, p < 0.0001. Interpretation of EMA test depends on MCV of the reference samples. If reference blood samples have lower MCV than the patients MCV, EMA test result might be negative. Due to different MCV values of RBCs in infancy and ca. Three months later, EMA test in neonates might be interpreted falsely negative. Samples from children younger than 3 months old had EMA test result 86.1 ± 11.7 %, whereas same samples that analyzed 4.1 ± 2.1 later had results of 75.4 ± 4.5 %, p < 0.05. Mean fluorescence of EMA-bound RBC depends on RBC's volume. MCV of reference samples affects EMA test results; thus, we recommend selection of reference samples with MCV in range of ±2 fL compared to MCV of patient RBC's.

  18. A framework for evaluating electronic health record vendor user-centered design and usability testing processes.

    Science.gov (United States)

    Ratwani, Raj M; Zachary Hettinger, A; Kosydar, Allison; Fairbanks, Rollin J; Hodgkins, Michael L

    2017-04-01

    Currently, there are few resources for electronic health record (EHR) purchasers and end users to understand the usability processes employed by EHR vendors during product design and development. We developed a framework, based on human factors literature and industry standards, to systematically evaluate the user-centered design processes and usability testing methods used by EHR vendors. We reviewed current usability certification requirements and the human factors literature to develop a 15-point framework for evaluating EHR products. The framework is based on 3 dimensions: user-centered design process, summative testing methodology, and summative testing results. Two vendor usability reports were retrieved from the Office of the National Coordinator's Certified Health IT Product List and were evaluated using the framework. One vendor scored low on the framework (5 pts) while the other vendor scored high on the framework (15 pts). The 2 scored vendor reports demonstrate the framework's ability to discriminate between the variabilities in vendor processes and to determine which vendors are meeting best practices. The framework provides a method to more easily comprehend EHR vendors' usability processes and serves to highlight where EHR vendors may be falling short in terms of best practices. The framework provides a greater level of transparency for both purchasers and end users of EHRs. The framework highlights the need for clearer certification requirements and suggests that the authorized certification bodies that examine vendor usability reports may need to be provided with clearer guidance. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    Science.gov (United States)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  20. Stochastic optimization of laboratory test workflow at metallurgical testing centers

    Directory of Open Access Journals (Sweden)

    F. Tošenovský

    2016-10-01

    Full Text Available The objective of the paper is to present a way to shorten the time required to perform laboratory tests of materials in metallurgy. The paper finds a relation between the time to perform a test of materials and the number of technicians carrying out the test. The relation can be used to optimize the number of technicians. The approach is based on probability theory, as the amount of material to be tested is unknown in advance, and uses powerful modelling techniques involving the generalized estimating equations.

  1. Propulsion and airframe aerodynamic interactions of supersonic V/STOL configurations. Volume 2: Wind tunnel test force and moment data report

    Science.gov (United States)

    Zilz, D. E.

    1985-01-01

    A wind tunnel model of a supersonic V/STOL fighter configuration has been tested to measure the aerodynamic interaction effects which can result from geometrically close-coupled propulsion system/airframe components. The approach was to configure the model to represent two different test techniques. One was a conventional test technique composed of two test modes. In the Flow-Through mode, absolute configuration aerodynamics are measured, including inlet/airframe interactions. In the Jet-Effects mode, incremental nozzle/airframe interactions are measured. The other test technique is a propulsion simulator approach, where a sub-scale, externally powered engine is mounted in the model. This allows proper measurement of inlet/airframe and nozzle/airframe interactions simultaneously. This is Volume 2 of 2: Wind Tunnel Test Force and Moment Data Report.

  2. 97 Medical Apparatuses tested at the Academic Medical Center (AMC) Amsterdam for interference by WLAN/WiFi signals

    NARCIS (Netherlands)

    Hensbroek, R.

    2009-01-01

    This research describes the influence of WLAN 1 signals on medical apparatuses in the Academic Medical Center (AMC) Amsterdam. The results in this report were obtained by testing medical equipment with WLAN signals. A comparable research was reported earlier. See TNO report KvL/P&Z 2007.117 dated

  3. Test Rack Development for Extended Operation of Advanced Stirling Convertors at NASA Glenn Research Center

    Science.gov (United States)

    Dugala, Gina M.

    2010-01-01

    The U.S. Department of Energy, Lockheed Martin Space Systems Company, Sunpower Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of free-piston Stirling convertors to achieve higher conversion efficiency than with currently available alternatives. One part of NASA GRC's support of ASRG development includes extended operation testing of Advanced Stirling Convertors (ASCs) developed by Sunpower Inc. and GRC. The ASC consists of a free-piston Stirling engine integrated with a linear alternator. NASA GRC has been building test facilities to support extended operation of the ASCs for several years. Operation of the convertors in the test facility provides convertor performance data over an extended period of time. One part of the test facility is the test rack, which provides a means for data collection, convertor control, and safe operation. Over the years, the test rack requirements have changed. The initial ASC test rack utilized an alternating-current (AC) bus for convertor control; the ASRG Engineering Unit (EU) test rack can operate with AC bus control or with an ASC Control Unit (ACU). A new test rack is being developed to support extended operation of the ASC-E2s with higher standards of documentation, component selection, and assembly practices. This paper discusses the differences among the ASC, ASRG EU, and ASC-E2 test racks.

  4. Update on Nonsurgical Lung Volume Reduction Procedures

    Directory of Open Access Journals (Sweden)

    J. Alberto Neder

    2016-01-01

    Full Text Available There has been a surge of interest in endoscopic lung volume reduction (ELVR strategies for advanced COPD. Valve implants, coil implants, biological LVR (BioLVR, bronchial thermal vapour ablation, and airway stents are used to induce lung deflation with the ultimate goal of improving respiratory mechanics and chronic dyspnea. Patients presenting with severe air trapping (e.g., inspiratory capacity/total lung capacity (TLC 225% predicted and thoracic hyperinflation (TLC > 150% predicted have the greatest potential to derive benefit from ELVR procedures. Pre-LVRS or ELVR assessment should ideally include cardiological evaluation, high resolution CT scan, ventilation and perfusion scintigraphy, full pulmonary function tests, and cardiopulmonary exercise testing. ELVR procedures are currently available in selected Canadian research centers as part of ethically approved clinical trials. If a decision is made to offer an ELVR procedure, one-way valves are the first option in the presence of complete lobar exclusion and no significant collateral ventilation. When the fissure is not complete, when collateral ventilation is evident in heterogeneous emphysema or when emphysema is homogeneous, coil implants or BioLVR (in that order are the next logical alternatives.

  5. PULSE COMBUSTOR DESIGN QUALIFICATION TEST AND CLEAN COAL FEEDSTOCK TEST - VOLUME I AND VOLUME II; FINAL

    International Nuclear Information System (INIS)

    Unknown

    2002-01-01

    For this Cooperative Agreement, the pulse heater module is the technology envelope for an indirectly heated steam reformer. The field of use of the steam reformer pursuant to this Cooperative Agreement with DOE is for the processing of sub-bituminous coals and lignite. The main focus is the mild gasification of such coals for the generation of both fuel gas and char-for the steel industry is the main focus. An alternate market application for the substitution of metallurgical coke is also presented. This project was devoted to qualification of a 253-tube pulse heater module. This module was designed, fabricated, installed, instrumented and tested in a fluidized bed test facility. Several test campaigns were conducted. This larger heater is a 3.5 times scale-up of the previous pulse heaters that had 72 tubes each. The smaller heater has been part of previous pilot field testing of the steam reformer at New Bern, North Carolina. The project also included collection and reduction of mild gasification process data from operation of the process development unit (PDU). The operation of the PDU was aimed at conditions required to produce char (and gas) for the Northshore Steel Operations. Northshore Steel supplied the coal for the process unit tests

  6. Index to Nuclear Safety: a technical progress review by chronology, permuted title, and author, Volume 18 (1) through Volume 22 (6)

    International Nuclear Information System (INIS)

    Cottrell, W.B.; Passiakos, M.

    1982-06-01

    This index to Nuclear Safety covers articles published in Nuclear Safety, Volume 18, Number 1 (January-February 1977) through Volume 22, Number 6 (November-December 1981). The index is divided into three section: a chronological list of articles (including abstracts), a permuted-title (KWIC) index, and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. Over 300 technical articles published in Nuclear Safety in the last 5 years are listed in this index

  7. Index to Nuclear Safety: a technical progress review by chronology, permuted title, and author, Volume 18 (1) through Volume 22 (6)

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Passiakos, M.

    1982-06-01

    This index to Nuclear Safety covers articles published in Nuclear Safety, Volume 18, Number 1 (January-February 1977) through Volume 22, Number 6 (November-December 1981). The index is divided into three section: a chronological list of articles (including abstracts), a permuted-title (KWIC) index, and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. Over 300 technical articles published in Nuclear Safety in the last 5 years are listed in this index.

  8. No association between Centers for Medicare and Medicaid services payments and volume of Medicare beneficiaries or per-capita health care costs for each state.

    Science.gov (United States)

    Harewood, Gavin C; Alsaffar, Omar

    2015-03-01

    The Centers for Medicare and Medicaid Services recently published data on Medicare payments to physicians for 2012. We investigated regional variations in payments to gastroenterologists and evaluated whether payments correlated with the number of Medicare patients in each state. We found that the mean payment per gastroenterologist in each state ranged from $35,293 in Minnesota to $175,028 in Mississippi. Adjusted per-physician payments ranged from $11 per patient in Hawaii to $62 per patient in Washington, DC. There was no correlation between the mean per-physician payment and the mean number of Medicare patients per physician (r = 0.09), there also was no correlation between the mean per-physician payment and the overall mean per-capita health care costs for each state (r = -0.22). There was a 5.6-fold difference between the states with the lowest and highest adjusted Medicare payments to gastroenterologists. Therefore, the Centers for Medicare and Medicaid Services payments do not appear to be associated with the volume of Medicare beneficiaries or overall per-capita health care costs for each state. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  9. Precision engineering center. 1988 Annual report, Volume VI

    Energy Technology Data Exchange (ETDEWEB)

    Dow, T. [ed.; Fornaro, R.; Keltie, R.; Paesler, M. [and others

    1988-12-01

    To reverse the downward trend in the balance of trade, American companies must concentrate on increasing research into new products, boosting productivity, and improving manufacturing processes. The Precision Engineering Center at North Carolina State University is a multidisciplinary research and graduate education program dedicated to providing the new technology necessary to respond to this challenge. One extremely demanding manufacturing area is the fabrication and assembly of optical systems. These systems are at the heart of such consumer products as cameras, lenses, copy machines, laser bar-code scanners, VCRs, and compact audio discs - products that the Japanese and other East Asian countries are building dominance. A second critical area is the fabrication of VLSI and ULSI circuits. The tolerances required to produce the next generation of components for such systems have created the need for new approaches - approaches that could either make or break America`s competitive position. This report contains individual reports on research projects grouped into three broad areas: measurement and actuation; real-time control; precision fabrication. Separate abstracts for these articles have been indexed into the energy database.

  10. Home medication support for childhood cancer: family-centered design and testing.

    Science.gov (United States)

    Walsh, Kathleen E; Biggins, Colleen; Blasko, Deb; Christiansen, Steven M; Fischer, Shira H; Keuker, Christopher; Klugman, Robert; Mazor, Kathleen M

    2014-11-01

    Errors in the use of medications at home by children with cancer are common, and interventions to support correct use are needed. We sought to (1) engage stakeholders in the design and development of an intervention to prevent errors in home medication use, and (2) evaluate the acceptability and usefulness of the intervention. We convened a multidisciplinary team of parents, clinicians, technology experts, and researchers to develop an intervention using a two-step user-centered design process. First, parents and oncologists provided input on the design. Second, a parent panel and two oncology nurses refined draft materials. In a feasibility study, we used questionnaires to assess usefulness and acceptability. Medication error rates were assessed via monthly telephone interviews with parents. We successfully partnered with parents, clinicians, and IT experts to develop Home Medication Support (HoMeS), a family-centered Web-based intervention. HoMeS includes a medication calendar with decision support, a communication tool, adverse effect information, a metric conversion chart, and other information. The 15 families in the feasibility study gave HoMeS high ratings for acceptability and usefulness. Half recorded information on the calendar to indicate to other caregivers that doses were given; 34% brought it to the clinic to communicate with their clinician about home medication use. There was no change in the rate of medication errors in this feasibility study. We created and tested a stakeholder-designed, Web-based intervention to support home chemotherapy use, which parents rated highly. This tool may prevent serious medication errors in a larger study. Copyright © 2014 by American Society of Clinical Oncology.

  11. Results and Interpretation of the WFRD ELS Distillation Down-Select Test Data

    Science.gov (United States)

    Delzeit, Lance Dean; Flynn, Michael; Carter, Layne; Long, David A.

    2010-01-01

    Testing of the Wiped-film Rotating-disk (WFRD) evaporator was conducted in support of the Exploration Life Support Distillation Down-Select Test. The WFRD was constructed at NASA Ames Research Center (ARC) and tested at NASA Marshall Space Flight Center (MSFC). The WFRD was delivered to MSFC in September 2009, and testing of solution #1 and solution #2 immediately following. Solution #1 was composed of humidity condensate and urine, including flush water and pretreatment chemicals. Solution #2 was composed of hygiene water, humidity condensate, and urine, including flush water and pretreatment chemicals. During the testing, the operational parameters of the WFRD were recorded and samples of the feed, brine, and product were collected and analyzed. The steady-state results of processing 414L of feed solution #1 and 1283L of feed solution #2 demonstrated that running the WFRD at a brine temperature of 50 C gave an average production rate of 16.7 L/hr. The specific energy consumption was 80.5W-hr/L. Data Analysis shows that the water recovery rates were 94% and 91%, respectively. The total mass of the WFRD as delivered to MSFC was 300 Kg. The volume of the tests stand rack was 1m width x 0.7m depth x 1.9m height or 1.5 cu m of which about half of the total volume is occupied by equipment. Chemical analysis of the distillate showed an average TOC of 20ppm, a pH of 3.5, and a conductivity of 98 mho/cm. The conductivity of the distillate, compared to the feed, decreased by 98.9%., the total ion concentration decreased by 99.6%, the total organics decreased 98.6%, and the metals were at or below detection limits

  12. New reference object for metrological performance testing of industrial CT systems

    DEFF Research Database (Denmark)

    Müller, Pavel; Hiller, Jochen; Cantatore, Angela

    2012-01-01

    This paper presents a new reference object, so called “CT ball plate”, used for metrological performance testing of industrial CT systems, and discusses both the calibration procedure using a tactile coordinate measuring machine and the first results carried out using an industrial CT scanner....... This artefact can be used to determine several characteristics of the CT system like, probing errors of spheres, length measuring errors between sphere centers, measurement errors in the whole CT volume and effects in connection with image artefacts....

  13. Transmissivity and storage coefficient estimates from slug tests, Naval Air Warfare Center, West Trenton, New Jersey

    Science.gov (United States)

    Fiore, Alex R.

    2014-01-01

    Slug tests were conducted on 56 observation wells open to bedrock at the former Naval Air Warfare Center (NAWC) in West Trenton, New Jersey. Aquifer transmissivity (T) and storage coefficient (S) values for most wells were estimated from slug-test data using the Cooper-Bredehoeft-Papadopulos method. Test data from three wells exhibited fast, underdamped water-level responses and were analyzed with the Butler high-K method. The range of T at NAWC was approximately 0.07 to 10,000 square feet per day. At 11 wells, water levels did not change measurably after 20 minutes following slug insertion; transmissivity at these 11 wells was estimated to be less than 0.07 square feet per day. The range of S was approximately 10-10 to 0.01, the mode being 10-10. Water-level responses for tests at three wells fit poorly to the type curves of both methods, indicating that these methods were not appropriate for adequately estimating T and S from those data.

  14. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    T.U. Mbaeri

    The ultrasound measurements of the testicular volume were calculated using the following three formulas: (a) length ... ticular growth, development and function. Studies in ... of the components of a minimum full evaluation of male infertility is palpation of ... opted for orchidectomy after counseling in our center. Subjects and ...

  15. On the evolution of stellar systems with a massive center

    International Nuclear Information System (INIS)

    Gurzadyan, V.G.; Kocharyan, A.A.

    1986-01-01

    The evolution of stellar systems with the massive center is investigated within the framework of dynamic system theory. Open dissipative systems, for which the Liouville theorem of the phase volume preservation is not implemented, are considered. Equations determining variation, in time, of main physical system parameters have been derived and studied. Results of the investigation show a principal possibility for determining the evolution path of stellar systems with the massive centers depending on physical parameters

  16. Biosecurity and Health Monitoring at the Zebrafish International Resource Center

    OpenAIRE

    Murray, Katrina N.; Varga, Zolt?n M.; Kent, Michael L.

    2016-01-01

    The Zebrafish International Resource Center (ZIRC) is a repository and distribution center for mutant, transgenic, and wild-type zebrafish. In recent years annual imports of new zebrafish lines to ZIRC have increased tremendously. In addition, after 15 years of research, we have identified some of the most virulent pathogens affecting zebrafish that should be avoided in large production facilities, such as ZIRC. Therefore, while importing a high volume of new lines we prioritize safeguarding ...

  17. Initial Flight Test of the Production Support Flight Control Computers at NASA Dryden Flight Research Center

    Science.gov (United States)

    Carter, John; Stephenson, Mark

    1999-01-01

    The NASA Dryden Flight Research Center has completed the initial flight test of a modified set of F/A-18 flight control computers that gives the aircraft a research control law capability. The production support flight control computers (PSFCC) provide an increased capability for flight research in the control law, handling qualities, and flight systems areas. The PSFCC feature a research flight control processor that is "piggybacked" onto the baseline F/A-18 flight control system. This research processor allows for pilot selection of research control law operation in flight. To validate flight operation, a replication of a standard F/A-18 control law was programmed into the research processor and flight-tested over a limited envelope. This paper provides a brief description of the system, summarizes the initial flight test of the PSFCC, and describes future experiments for the PSFCC.

  18. Development, field testing and implementation of automated hydraulically controlled, variable volume loading systems for reciprocating compressors

    Energy Technology Data Exchange (ETDEWEB)

    Hickman, Dwayne A. [ACI Services, Inc., Cambridge, OH (United States); Slupsky, John [Kvaerner Process Systems, Calgary, Alberta (Canada); Chrisman, Bruce M.; Hurley, Tom J. [Cooper Energy Services, Oklahoma City, OK (United States). Ajax Division

    2003-07-01

    Automated, variable volume unloaders provide the ability to smoothly load/unload reciprocating compressors to maintain ideal operations in ever-changing environments. Potential advantages provided by this load control system include: maximizing unit capacity, optimizing power economy, maintaining low exhaust emissions, and maintaining process suction and discharge pressures. Obstacles foreseen include: reliability, stability, serviceability and automation integration. Results desired include: increased productivity for the compressor and its operators, increased up time, and more stable process control. This presentation covers: system design features with descriptions of how different types of the devices were developed, initial test data, and how they can be effectively operated; three actual-case studies detailing the reasons why automated, hydraulically controlled, variable volume, head-end unloaders were chosen over other types of unloading devices; sophisticated software used in determining the device sizing and predicted performance; mechanical and field considerations; installation, serviceability and operating considerations; device control issues, including PC and PLC considerations; monitoring of actual performance and comparison of such with predicted performance; analysis of mechanical reliability and stability; and preliminary costs versus return on investment analysis. (author)

  19. Axes of resistance for tooth movement: does the center of resistance exist in 3-dimensional space?

    Science.gov (United States)

    Viecilli, Rodrigo F; Budiman, Amanda; Burstone, Charles J

    2013-02-01

    The center of resistance is considered the most important reference point for tooth movement. It is often stated that forces through this point will result in tooth translation. The purpose of this article is to report the results of numeric experiments testing the hypothesis that centers of resistance do not exist in space as 3-dimensional points, primarily because of the geometric asymmetry of the periodontal ligament. As an alternative theory, we propose that, for an arbitrary tooth, translation references can be determined by 2-dimensional projection intersections of 3-dimensional axes of resistance. Finite element analyses were conducted on a maxillary first molar model to determine the position of the axes of rotation generated by 3-dimensional couples. Translation tests were performed to compare tooth movement by using different combinations of axes of resistance as references. The couple-generated axes of rotation did not intersect in 3 dimensions; therefore, they do not determine a 3-dimensional center of resistance. Translation was obtained by using projection intersections of the 2 axes of resistance perpendicular to the force direction. Three-dimensional axes of resistance, or their 2-dimensional projection intersections, should be used to plan movement of an arbitrary tooth. Clinical approximations to a small 3-dimensional "center of resistance volume" might be adequate in nearly symmetric periodontal ligament cases. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  20. A novel method for reproducibly measuring the effects of interventions to improve emotional climate, indices of team skills and communication, and threat to patient outcome in a high-volume thoracic surgery center.

    Science.gov (United States)

    Nurok, Michael; Lipsitz, Stuart; Satwicz, Paul; Kelly, Andrea; Frankel, Allan

    2010-05-01

    To create and test a reproducible method for measuring emotional climate, surgical team skills, and threats to patient outcome by conducting an observational study to assess the impact of a surgical team skills and communication improvement intervention on these measurements. Observational study. Operating rooms in a high-volume thoracic surgery center from September 5, 2007, through June 30, 2008. Thoracic surgery operating room teams. Two 90-minute team skills training sessions focused on findings from a standardized safety culture survey administered to all participants and highlighting positive and problematic aspects of team skills, communication, and leadership. The sessions created an interactive forum to educate team members on the importance of communication and to role-play optimal interactive and communication strategies. Calculated indices of emotional climate, team skills, and threat to patient outcome. The calculated communication and team skills score improved from the preintervention to postintervention periods, but the improvement extinguished during the 3 months after the intervention (P skills and communication and decrease a calculated score of threats to patient outcome. However, the effect is only durable for threats to patient outcome.

  1. The ADVANCE project: Formal evaluation of the targeted deployment. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-01-01

    The Advanced Driver and Vehicle Advisory Navigation ConcEpt (ADVANCE) was an invehicle advanced traveler information system (ATIS) that operated in the northwest suburbs of Chicago, Illinois. It was designed to provide origin-destination shortest-time route guidance to a vehicle based on (a) an on-board static (fixed) data base of average network link travel times by time of day, combined as available and appropriate with (b) dynamic (real-time) information on traffic conditions provided by radio frequency (RF) communications to and from a traffic information center (TIC). Originally conceived in 1990 as a major project that would have installed 3,000 to 5,000 route guidance units in privately owned vehicles throughout the test area, ADVANCE was restructured in 1995 as a {open_quotes}targeted deployment,{close_quotes} in which approximately 80 vehicles were to be equipped with the guidance units - Mobile Navigation Assistants (MNAs) - to be in full communication with the TIC while driving the ADVANCE test area road system. Volume one consists of the evaluation managers overview report, and several appendices containing test results.

  2. Retrofit of waste-to-energy facilities equipped with electrostatic precipitators. Volume III: Test protocol

    Energy Technology Data Exchange (ETDEWEB)

    Rigo, H.G. [Rigo & Rigo Associates, Inc., Berea, OH (US); Chandler, A.J. [A.J. Chandler & Associates, Inc., Toronto, Ontario (Canada)

    1996-04-01

    The American Society of Mechanical Engineers' [ASME] Center for Research and Technology Development [CRTD] has been awarded a subcontract by the National Renewable Energy Laboratory [NREL] to demonstrate the technical performance and viability of flue gas temperature control in combination with dry acid gas reagent and activated carbon injection at an existing electrostatic precipitator [ESP] equipped municipal waste combustor [MWC]. The objective of this proof-of-concept demonstration test is to economically and reliably meet 40 CFR 60 Subpart Cb Emissions Guidelines for MWC's at existing ESP equipped facilities. The effort is being directed by a Subcommittee of tile ASME Research Committee on Industrial and Municipal Wastes [RCIMW] chaired by Dave Hoecke. Mr. Greg Barthold of ASME/CRTD is the Project Manager. ASME/CRTD contracted with Rigo & Rigo Associates, Inc. in cooperation with A.J. Chandler & Associates, Ltd. to be the Principal Investigator for the project and manage the day-t o-day aspects of the program, conduct the testing reduce and interpret the data and prepare the report. Testing will be conducted at the 2 by 210 TPD, ESP equipped MWC at the Davis County Resource Recovery Facility in Layton, Utah. The test plan calls for duplicate metals (Cd, Pb and Hg), dioxin and acid gas runs.

  3. Volume independence in large Nc QCD-like gauge theories

    International Nuclear Information System (INIS)

    Kovtun, Pavel; Uensal, Mithat; Yaffe, Laurence G.

    2007-01-01

    Volume independence in large N c gauge theories may be viewed as a generalized orbifold equivalence. The reduction to zero volume (or Eguchi-Kawai reduction) is a special case of this equivalence. So is temperature independence in confining phases. A natural generalization concerns volume independence in 'theory space' of quiver gauge theories. In pure Yang-Mills theory, the failure of volume independence for sufficiently small volumes (at weak coupling) due to spontaneous breaking of center symmetry, together with its validity above a critical size, nicely illustrate the symmetry realization conditions which are both necessary and sufficient for large N c orbifold equivalence. The existence of a minimal size below which volume independence fails also applies to Yang-Mills theory with antisymmetric representation fermions [QCD(AS)]. However, in Yang-Mills theory with adjoint representation fermions [QCD(Adj)], endowed with periodic boundary conditions, volume independence remains valid down to arbitrarily small size. In sufficiently large volumes, QCD(Adj) and QCD(AS) have a large N c ''orientifold'' equivalence, provided charge conjugation symmetry is unbroken in the latter theory. Therefore, via a combined orbifold-orientifold mapping, a well-defined large N c equivalence exists between QCD(AS) in large, or infinite, volume and QCD(Adj) in arbitrarily small volume. Since asymptotically free gauge theories, such as QCD(Adj), are much easier to study (analytically or numerically) in small volume, this equivalence should allow greater understanding of large N c QCD in infinite volume

  4. Interobserver and Intraobserver Reproducibility with Volume Dynamic Contrast Enhanced Computed Tomography (DCE-CT) in Gastroesophageal Junction Cancer

    DEFF Research Database (Denmark)

    Lundsgaard Hansen, Martin; Fallentin, Eva; Axelsen, Thomas

    2016-01-01

    -dimensional (2D) fixed ROIs) placed in the tumor periphery, (II) 2-dimensional regions of interest (2D-ROI) along the tumor border in the tumor center, and (III) 3-dimensional volumes of interest (3D-VOI) containing the entire tumor volume. Arterial flow, blood volume and permeability (k(trans)) were recorded...

  5. Effects of gauge volume on pseudo-strain induced in strain measurement using time-of-flight neutron diffraction

    International Nuclear Information System (INIS)

    Suzuki, Hiroshi; Harjo, Stefanus; Abe, Jun; Xu, Pingguang; Aizawa, Kazuya; Akita, Koichi

    2013-01-01

    Spurious or pseudo-strains observed in time-of-flight (TOF) neutron diffraction due to neutron attenuation, surface-effects and a strain distribution within the gauge volume were investigated. Experiments were carried out on annealed and bent ferritic steel bars to test these effects. The most representative position in the gauge volume corresponds to the neutron-weighted center of gravity (ncog), which takes into account variations in intensity within the gauge volume due to neutron attenuation and/or absence of material in the gauge volume. The average strain in the gauge volume was observed to be weighted towards the ncog position but following an increase in the size of the gauge volume the weighted average strain was changed because of the change in the ncog position when a strain gradient appeared within the gauge volume. On the other hand, typical pseudo-strains, which are well known, did appear in through-surface strain measurements when the gauge volume was incompletely filled by the sample. Tensile pseudo-strains due to the surface-effect increased near the sample surface and exhibited a similar trend regardless of the size of the gauge volume, while the pseudo-strains increased faster for the smaller gauge volume. Furthermore, a pseudo-strain due to a change in the ncog position was observed even when the gauge volume was perfectly filled in the sample, and it increased with an increase in the size of the gauge volume. These pseudo-strains measured were much larger than those simulated by the conventional modeling, whereas they were simulated by taking into account an incident neutron beam divergence additionally in the model. Therefore, the incident divergence of the incident neutron beam must be carefully designed to avoid pseudo-strains in time-of-flight neutron diffractometry

  6. Examining the effect of psychopathic traits on gray matter volume in a community substance abuse sample.

    Science.gov (United States)

    Cope, Lora M; Shane, Matthew S; Segall, Judith M; Nyalakanti, Prashanth K; Stevens, Michael C; Pearlson, Godfrey D; Calhoun, Vince D; Kiehl, Kent A

    2012-11-30

    Psychopathy is believed to be associated with brain abnormalities in both paralimbic (i.e., orbitofrontal cortex, insula, temporal pole, parahippocampal gyrus, posterior cingulate) and limbic (i.e., amygdala, hippocampus, anterior cingulate) regions. Recent structural imaging studies in both community and prison samples are beginning to support this view. Sixty-six participants, recruited from community corrections centers, were administered the Hare psychopathy checklist-revised (PCL-R), and underwent magnetic resonance imaging (MRI). Voxel-based morphometry was used to test the hypothesis that psychopathic traits would be associated with gray matter reductions in limbic and paralimbic regions. Effects of lifetime drug and alcohol use on gray matter volume were covaried. Psychopathic traits were negatively associated with gray matter volumes in right insula and right hippocampus. Additionally, psychopathic traits were positively associated with gray matter volumes in bilateral orbital frontal cortex and right anterior cingulate. Exploratory regression analyses indicated that gray matter volumes within right hippocampus and left orbital frontal cortex combined to explain 21.8% of the variance in psychopathy scores. These results support the notion that psychopathic traits are associated with abnormal limbic and paralimbic gray matter volume. Furthermore, gray matter increases in areas shown to be functionally impaired suggest that the structure-function relationship may be more nuanced than previously thought. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. The Need and Opportunity for an Integrated Research, Development and Testing Center in the Alaskan High Arctic

    Science.gov (United States)

    Hardesty, J. O.; Ivey, M.; Helsel, F.; Dexheimer, D.; Lucero, D. A.; Cahill, C. F.; Roesler, E. L.

    2017-12-01

    This presentation will make the case for development of a permanent integrated High Arctic research and testing center at Oliktok Point, Alaska; taking advantage of existing assets and infrastructure, controlled airspace, an active UAS program and local partnerships. Arctic research stations provide critical monitoring and research on climate change for conditions and trends in the Arctic. The US Chair of the Arctic Council increased awareness of gaps in our understanding of Artic systems, scarce monitoring, lack of infrastructure and readiness for emergency response. Less sea ice brings competition for commercial shipping and resource extraction. Search and rescue, pollution mitigation and safe navigation need real-time, wide-area monitoring to respond to events. Multi-national responses for international traffic will drive a greater security presence to protect citizens and sovereign interests. To address research and technology gaps, there is a national need for a US High Arctic Center (USHARC) with an approach to partner stakeholders from science, safety and security to develop comprehensive solutions. The Station should offer year-round use, logistic support and access to varied ecological settings; phased adaptation to changing needs; and support testing of technologies such as multiple autonomous platforms, renewable energies and microgrids, and sensors in Arctic settings. We propose an Arctic Center at Oliktok Point, Alaska. Combined with the Toolik Field Station and Barrow Environmental Observatory, they form a US network of Arctic Stations. An Oliktok Point Station can provide complementary and unique assets that include: access via land, sea and air; coastal and terrestrial ecologies; controlled airspaces across land and ocean; medical and logistic support; atmospheric observations from an adjacent ARM facility; connections to Barrow and Toolik; fiber-optic communications; University of Alaska Fairbanks UAS Test Facility partnership; and an airstrip and

  8. AN/FSY-3 Space Fence System – Sensor Site One/Operations Center Integration Status and Sensor Site Two Planned Capability

    Science.gov (United States)

    Fonder, G. P.; Hack, P. J.; Hughes, M. R.

    This paper covers two topics related to Space Fence System development: Sensor Site One / Operations Center construction and integration status including risk reduction integration and test efforts at the Moorestown, NJ Integrated Test Bed (ITB); and the planned capability of Sensor Site Two. The AN/FSY-3 Space Fence System is a ground-based system of S-band radars integrated with an Operations Center designed to greatly enhance the Air Force Space Surveillance network. The radar architecture is based on Digital Beam-forming. This capability permits tremendous user-defined flexibility to customize volume surveillance and track sectors instantaneously without impacting routine surveillance functions. Space Fence provides unprecedented sensitivity, coverage and tracking accuracy, and contributes to key mission threads with the ability to detect, track and catalog small objects in LEO, MEO and GEO. The system is net-centric and will seamlessly integrate into the existing Space Surveillance Network, providing services to external users—such as JSpOC—and coordinating handoffs to other SSN sites. Sensor Site One construction on the Kwajalein Atoll is in progress and nearing completion. The Operations Center in Huntsville, Alabama has been configured and will be integrated with Sensor Site One in the coming months. System hardware, firmware, and software is undergoing integration testing at the Mooretown, NJ ITB and will be deployed at Sensor Site One and the Operations Center. The preliminary design for Sensor Site Two is complete and will provide critical coverage, timeliness, and operational flexibility to the overall system.

  9. ILC Reference Design Report Volume 1 - Executive Summary

    CERN Document Server

    Brau, James; Walker, Nicholas; Aarons, Gerald; Abe, Toshinori; Abernathy, Jason; Ablikim, Medina; Abramowicz, Halina; Adey, David; Adloff, Catherine; Adolphsen, Chris; Afanaciev, Konstantin; Agapov, Ilya; Ahn, Jung-Keun; Aihara, Hiroaki; Akemoto, Mitsuo; del Carmen Alabau, Maria; Albert, Justin; Albrecht, Hartwig; Albrecht, Michael; Alesini, David; Alexander, Gideon; Alexander, Jim; Allison, Wade; Amann, John; Amirikas, Ramila; An, Qi; Anami, Shozo; Ananthanarayan, B.; Anderson, Terry; Andricek, Ladislav; Anduze, Marc; Anerella, Michael; Anfimov, Nikolai; Angal-Kalinin, Deepa; Antipov, Sergei; Antoine, Claire; Aoki, Mayumi; Aoza, Atsushi; Aplin, Steve; Appleby, Rob; Arai, Yasuo; Araki, Sakae; Arkan, Tug; Arnold, Ned; Arnold, Ray; Arnowitt, Richard; Artru, Xavier; Arya, Kunal; Aryshev, Alexander; Asakawa, Eri; Asiri, Fred; Asner, David; Atac, Muzaffer; Atoian, Grigor; Attié, David; Augustin, Jean-Eudes; Augustine, David B.; Ayres, Bradley; Aziz, Tariq; Baars, Derek; Badaud, Frederique; Baddams, Nigel; Bagger, Jonathan; Bai, Sha; Bailey, David; Bailey, Ian R.; Baker, David; Balalykin, Nikolai I.; Balbuena, Juan Pablo; Baldy, Jean-Luc; Ball, Markus; Ball, Maurice; Ballestrero, Alessandro; Ballin, Jamie; Baltay, Charles; Bambade, Philip; Ban, Syuichi; Band, Henry; Bane, Karl; Banerjee, Bakul; Barbanotti, Serena; Barbareschi, Daniele; Barbaro-Galtieri, Angela; Barber, Desmond P.; Barbi, Mauricio; Bardin, Dmitri Y.; Barish, Barry; Barklow, Timothy L.; Barlow, Roger; Barnes, Virgil E.; Barone, Maura; Bartels, Christoph; Bartsch, Valeria; Basu, Rahul; Battaglia, Marco; Batygin, Yuri; Baudot, Jerome; Baur, Ulrich; Elwyn Baynham, D.; Beard, Carl; Bebek, Chris; Bechtle, Philip; Becker, Ulrich J.; Bedeschi, Franco; Bedjidian, Marc; Behera, Prafulla; Behnke, Ties; Bellantoni, Leo; Bellerive, Alain; Bellomo, Paul; Bentson, Lynn D.; Benyamna, Mustapha; Bergauer, Thomas; Berger, Edmond; Bergholz, Matthias; Beri, Suman; Berndt, Martin; Bernreuther, Werner; Bertolini, Alessandro; Besancon, Marc; Besson, Auguste; Beteille, Andre; Bettoni, Simona; Beyer, Michael; Bhandari, R.K.; Bharadwaj, Vinod; Bhatnagar, Vipin; Bhattacharya, Satyaki; Bhattacharyya, Gautam; Bhattacherjee, Biplob; Bhuyan, Ruchika; Bi, Xiao-Jun; Biagini, Marica; Bialowons, Wilhelm; Biebel, Otmar; Bieler, Thomas; Bierwagen, John; Birch, Alison; Bisset, Mike; Biswal, S.S.; Blackmore, Victoria; Blair, Grahame; Blanchard, Guillaume; Blazey, Gerald; Blue, Andrew; Blümlein, Johannes; Boffo, Christian; Bohn, Courtlandt; Boiko, V.I.; Boisvert, Veronique; Bondarchuk, Eduard N.; Boni, Roberto; Bonvicini, Giovanni; Boogert, Stewart; Boonekamp, Maarten; Boorman, Gary; Borras, Kerstin; Bortoletto, Daniela; Bosco, Alessio; Bosio, Carlo; Bosland, Pierre; Bosotti, Angelo; Boudry, Vincent; Boumediene, Djamel-Eddine; Bouquet, Bernard; Bourov, Serguei; Bowden, Gordon; Bower, Gary; Boyarski, Adam; Bozovic-Jelisavcic, Ivanka; Bozzi, Concezio; Brachmann, Axel; Bradshaw, Tom W.; Brandt, Andrew; Brasser, Hans Peter; Brau, Benjamin; Breidenbach, Martin; Bricker, Steve; Brient, Jean-Claude; Brock, Ian; Brodsky, Stanley; Brooksby, Craig; Broome, Timothy A.; Brown, David; Brown, David; Brownell, James H.; Bruchon, Mélanie; Brueck, Heiner; Brummitt, Amanda J.; Brun, Nicole; Buchholz, Peter; Budagov, Yulian A.; Bulgheroni, Antonio; Bulyak, Eugene; Bungau, Adriana; Bürger, Jochen; Burke, Dan; Burkhart, Craig; Burrows, Philip; Burt, Graeme; Burton, David; Büsser, Karsten; Butler, John; Butterworth, Jonathan; Buzulutskov, Alexei; Cabruja, Enric; Caccia, Massimo; Cai, Yunhai; Calcaterra, Alessandro; Caliier, Stephane; Camporesi, Tiziano; Cao, Jun-Jie; Cao, J.S.; Capatina, Ofelia; Cappellini, Chiara; Carcagno, Ruben; Carena, Marcela; Carloganu, Cristina; Carosi, Roberto; Stephen Carr, F.; Carrion, Francisco; Carter, Harry F.; Carter, John; Carwardine, John; Cassel, Richard; Cassell, Ronald; Cavallari, Giorgio; Cavallo, Emanuela; Cembranos, Jose A.R.; Chakraborty, Dhiman; Chandez, Frederic; Charles, Matthew; Chase, Brian; Chattopadhyay, Subhasis; Chauveau, Jacques; Chefdeville, Maximilien; Chehab, Robert; Chel, Stéphane; Chelkov, Georgy; Chen, Chiping; Chen, He Sheng; Chen, Huai Bi; Chen, Jia Er; Chen, Sen Yu; Chen, Shaomin; Chen, Shenjian; Chen, Xun; Chen, Yuan Bo; Cheng, Jian; Chevallier, M.; Chi, Yun Long; Chickering, William; Cho, Gi-Chol; Cho, Moo-Hyun; Choi, Jin-Hyuk; Choi, Jong Bum; Choi, Seong Youl; Choi, Young-Il; Choudhary, Brajesh; Choudhury, Debajyoti; Rai Choudhury, S.; Christian, David; Christian, Glenn; Christophe, Grojean; Chung, Jin-Hyuk; Church, Mike; Ciborowski, Jacek; Cihangir, Selcuk; Ciovati, Gianluigi; Clarke, Christine; Clarke, Don G.; Clarke, James A.; Clements, Elizabeth; Coca, Cornelia; Coe, Paul; Cogan, John; Colas, Paul; Collard, Caroline; Colledani, Claude; Combaret, Christophe; Comerma, Albert; Compton, Chris; Constance, Ben; Conway, John; Cook, Ed; Cooke, Peter; Cooper, William; Corcoran, Sean; Cornat, Rémi; Corner, Laura; Cortina Gil, Eduardo; Clay Corvin, W.; Cotta Ramusino, Angelo; Cowan, Ray; Crawford, Curtis; Cremaldi, Lucien M; Crittenden, James A.; Cussans, David; Cvach, Jaroslav; da Silva, Wilfrid; Dabiri Khah, Hamid; Dabrowski, Anne; Dabrowski, Wladyslaw; Dadoun, Olivier; Dai, Jian Ping; Dainton, John; Daly, Colin; Damerell, Chris; Danilov, Mikhail; Daniluk, Witold; Daram, Sarojini; Datta, Anindya; Dauncey, Paul; David, Jacques; Davier, Michel; Davies, Ken P.; Dawson, Sally; De Boer, Wim; De Curtis, Stefania; De Groot, Nicolo; de la Taille, Christophe; de Lira, Antonio; De Roeck, Albert; de Sangro, Riccardo; De Santis,Stefano; Deacon, Laurence; Deandrea, Aldo; Dehmelt, Klaus; Delagnes, Eric; Delahaye, Jean-Pierre; Delebecque, Pierre; Delerue, Nicholas; Delferriere, Olivier; Demarteau, Marcel; Deng, Zhi; Denisov, Yu.N.; Densham, Christopher J.; Desch, Klaus; Deshpande, Nilendra; Devanz, Guillaume; Devetak, Erik; Dexter, Amos; Di benedetto, Vito; Diéguez, Angel; Diener, Ralf; Dinh, Nguyen Dinh; Dixit, Madhu; Dixit, Sudhir; Djouadi, Abdelhak; Dolezal, Zdenek; Dollan, Ralph; Dong, Dong; Dong, Hai Yi; Dorfan, Jonathan; Dorokhov, Andrei; Doucas, George; Downing, Robert; Doyle, Eric; Doziere, Guy; Drago, Alessandro; Dragt, Alex; Drake, Gary; Drásal, Zbynek; Dreiner, Herbert; Drell, Persis; Driouichi, Chafik; Drozhdin, Alexandr; Drugakov, Vladimir; Du, Shuxian; Dugan, Gerald; Duginov, Viktor; Dulinski, Wojciech; Dulucq, Frederic; Dutta, Sukanta; Dwivedi, Jishnu; Dychkant, Alexandre; Dzahini, Daniel; Eckerlin, Guenter; Edwards, Helen; Ehrenfeld, Wolfgang; Ehrlichman, Michael; Ehrlichmann, Heiko; Eigen, Gerald; Elagin, Andrey; Elementi, Luciano; Eliasson, Peder; Ellis, John; Ellwood, George; Elsen, Eckhard; Emery, Louis; Enami, Kazuhiro; Endo, Kuninori; Enomoto, Atsushi; Eozénou, Fabien; Erbacher, Robin; Erickson, Roger; Oleg Eyser, K.; Fadeyev, Vitaliy; Fang, Shou Xian; Fant, Karen; Fasso, Alberto; Faucci Giannelli, Michele; Fehlberg, John; Feld, Lutz; Feng, Jonathan L.; Ferguson, John; Fernandez-Garcia, Marcos; Luis Fernandez-Hernando, J.; Fiala, Pavel; Fieguth, Ted; Finch, Alexander; Finocchiaro, Giuseppe; Fischer, Peter; Fisher, Peter; Eugene Fisk, H.; Fitton, Mike D.; Fleck, Ivor; Fleischer, Manfred; Fleury, Julien; Flood, Kevin; Foley, Mike; Ford, Richard; Fortin, Dominique; Foster, Brian; Fourches, Nicolas; Francis, Kurt; Frey, Ariane; Frey, Raymond; Friedsam, Horst; Frisch, Josef; Frishman, Anatoli; Fuerst, Joel; Fujii, Keisuke; Fujimoto, Junpei; Fukuda, Masafumi; Fukuda, Shigeki; Funahashi, Yoshisato; Funk, Warren; Furletova, Julia; Furukawa, Kazuro; Furuta, Fumio; Fusayasu, Takahiro; Fuster, Juan; Gadow, Karsten; Gaede, Frank; Gaglione, Renaud; Gai, Wei; Gajewski, Jan; Galik, Richard; Galkin, Alexei; Galkin, Valery; Gallin-Martel, Laurent; Gannaway, Fred; Gao, Jian She; Gao, Jie; Gao, Yuanning; Garbincius, Peter; Garcia-Tabares, Luis; Garren, Lynn; Garrido, Luís; Garutti, Erika; Garvey, Terry; Garwin, Edward; Gascón, David; Gastal, Martin; Gatto, Corrado; Gatto, Raoul; Gay, Pascal; Ge, Lixin; Ge, Ming Qi; Ge, Rui; Geiser, Achim; Gellrich, Andreas; Genat, Jean-Francois; Geng, Zhe Qiao; Gentile, Simonetta; Gerbick, Scot; Gerig, Rod; Ghosh, Dilip Kumar; Ghosh, Kirtiman; Gibbons, Lawrence; Giganon, Arnaud; Gillespie, Allan; Gillman, Tony; Ginzburg, Ilya; Giomataris, Ioannis; Giunta, Michele; Gladkikh, Peter; Gluza, Janusz; Godbole, Rohini; Godfrey, Stephen; Goldhaber, Gerson; Goldstein, Joel; Gollin, George D.; Gonzalez-Sanchez, Francisco Javier; Goodrick, Maurice; Gornushkin, Yuri; Gostkin, Mikhail; Gottschalk, Erik; Goudket, Philippe; Gough Eschrich, Ivo; Gournaris, Filimon; Graciani, Ricardo; Graf, Norman; Grah, Christian; Grancagnolo, Francesco; Grandjean, Damien; Grannis, Paul; Grassellino, Anna; Graugés, Eugeni; Gray, Stephen; Green, Michael; Greenhalgh, Justin; Greenshaw, Timothy; Grefe, Christian; Gregor, Ingrid-Maria; Grenier, Gerald; Grimes, Mark; Grimm, Terry; Gris, Philippe; Grivaz, Jean-Francois; Groll, Marius; Gronberg, Jeffrey; Grondin, Denis; Groom, Donald; Gross, Eilam; Grunewald, Martin; Grupen, Claus; Grzelak, Grzegorz; Gu, Jun; Gu, Yun-Ting; Guchait, Monoranjan; Guiducci, Susanna; Guler, Ali Murat; Guler, Hayg; Gulmez, Erhan; Gunion, John; Guo, Zhi Yu; Gurtu, Atul; Ha, Huy Bang; Haas, Tobias; Haase, Andy; Haba, Naoyuki; Haber, Howard; Haensel, Stephan; Hagge, Lars; Hagura, Hiroyuki; Hajdu, Csaba; Haller, Gunther; Haller, Johannes; Hallermann, Lea; Halyo, Valerie; Hamaguchi, Koichi; Hammond, Larry; Han, Liang; Han, Tao; Hand, Louis; Handu, Virender K.; Hano, Hitoshi; Hansen, Christian; Hansen, Jørn Dines; Hansen, Jorgen Beck; Hara, Kazufumi; Harder, Kristian; Hartin, Anthony; Hartung, Walter; Hast, Carsten; Hauptman, John; Hauschild, Michael; Hauviller, Claude; Havranek, Miroslav; Hawkes, Chris; Hawkings, Richard; Hayano, Hitoshi; Hazumi, Masashi; He, An; He, Hong Jian; Hearty, Christopher; Heath, Helen; Hebbeker, Thomas; Hedberg, Vincent; Hedin, David; Heifets, Samuel; Heinemeyer, Sven; Heini, Sebastien; Helebrant, Christian; Helms, Richard; Heltsley, Brian; Henrot-Versille, Sophie; Henschel, Hans; Hensel, Carsten; Hermel, Richard; Herms, Atilà; Herten, Gregor; Hesselbach, Stefan; Heuer, Rolf-Dieter; Heusch, Clemens A.; Hewett, Joanne; Higashi, Norio; Higashi, Takatoshi; Higashi, Yasuo; Higo, Toshiyasu; Hildreth, Michael D.; Hiller, Karlheinz; Hillert, Sonja; Hillier, Stephen James; Himel, Thomas; Himmi, Abdelkader; Hinchliffe, Ian; Hioki, Zenro; Hirano, Koichiro; Hirose, Tachishige; Hisamatsu, Hiromi; Hisano, Junji; Hlaing, Chit Thu; Hock, Kai Meng; Hoeferkamp, Martin; Hohlfeld, Mark; Honda, Yousuke; Hong, Juho; Hong, Tae Min; Honma, Hiroyuki; Horii, Yasuyuki; Horvath, Dezso; Hosoyama, Kenji; Hostachy, Jean-Yves; Hou, Mi; Hou, Wei-Shu; Howell, David; Hronek, Maxine; Hsiung, Yee B.; Hu, Bo; Hu, Tao; Huang, Jung-Yun; Huang, Tong Ming; Huang, Wen Hui; Huedem, Emil; Huggard, Peter; Hugonie, Cyril; Hu-Guo, Christine; Huitu, Katri; Hwang, Youngseok; Idzik, Marek; Ignatenko, Alexandr; Ignatov, Fedor; Ikeda, Hirokazu; Ikematsu, Katsumasa; Ilicheva, Tatiana; Imbault, Didier; Imhof, Andreas; Incagli, Marco; Ingbir, Ronen; Inoue, Hitoshi; Inoue, Youichi; Introzzi, Gianluca; Ioakeimidi, Katerina; Ishihara, Satoshi; Ishikawa, Akimasa; Ishikawa, Tadashi; Issakov, Vladimir; Ito, Kazutoshi; Ivanov, V.V.; Ivanov, Valentin; Ivanyushenkov, Yury; Iwasaki, Masako; Iwashita, Yoshihisa; Jackson, David; Jackson, Frank; Jacobsen, Bob; Jaganathan, Ramaswamy; Jamison, Steven; Janssen, Matthias Enno; Jaramillo-Echeverria, Richard; Jaros, John; Jauffret, Clement; Jawale, Suresh B.; Jeans, Daniel; Jedziniak, Ron; Jeffery, Ben; Jehanno, Didier; Jenner, Leo J.; Jensen, Chris; Jensen, David R.; Jiang, Hairong; Jiang, Xiao Ming; Jimbo, Masato; Jin, Shan; Keith Jobe, R.; Johnson, Anthony; Johnson, Erik; Johnson, Matt; Johnston, Michael; Joireman, Paul; Jokic, Stevan; Jones, James; Jones, Roger M.; Jongewaard, Erik; Jönsson, Leif; Joshi, Gopal; Joshi, Satish C.; Jung, Jin-Young; Junk, Thomas; Juste, Aurelio; Kado, Marumi; Kadyk, John; Käfer, Daniela; Kako, Eiji; Kalavase, Puneeth; Kalinin, Alexander; Kalinowski, Jan; Kamitani, Takuya; Kamiya, Yoshio; Kamiya, Yukihide; Kamoshita, Jun-ichi; Kananov, Sergey; Kanaya, Kazuyuki; Kanazawa, Ken-ichi; Kanemura, Shinya; Kang, Heung-Sik; Kang, Wen; Kanjial, D.; Kapusta, Frédéric; Karataev, Pavel; Karchin, Paul E.; Karlen, Dean; Karyotakis, Yannis; Kashikhin, Vladimir; Kashiwagi, Shigeru; Kasley, Paul; Katagiri, Hiroaki; Kato, Takashi; Kato, Yukihiro; Katzy, Judith; Kaukher, Alexander; Kaur, Manjit; Kawagoe, Kiyotomo; Kawamura, Hiroyuki; Kazakov, Sergei; Kekelidze, V.D.; Keller, Lewis; Kelley, Michael; Kelly, Marc; Kelly, Michael; Kennedy, Kurt; Kephart, Robert; Keung, Justin; Khainovski, Oleg; Khan, Sameen Ahmed; Khare, Prashant; Khovansky, Nikolai; Kiesling, Christian; Kikuchi, Mitsuo; Kilian, Wolfgang; Killenberg, Martin; Kim, Donghee; Kim, Eun San; Kim, Eun-Joo; Kim, Guinyun; Kim, Hongjoo; Kim, Hyoungsuk; Kim, Hyun-Chui; Kim, Jonghoon; Kim, Kwang-Je; Kim, Kyung Sook; Kim, Peter; Kim, Seunghwan; Kim, Shin-Hong; Kim, Sun Kee; Kim, Tae Jeong; Kim, Youngim; Kim, Young-Kee; Kimmitt, Maurice; Kirby, Robert; Kircher, François; Kisielewska, Danuta; Kittel, Olaf; Klanner, Robert; Klebaner, Arkadiy L.; Kleinwort, Claus; Klimkovich, Tatsiana; Klinkby, Esben; Kluth, Stefan; Knecht, Marc; Kneisel, Peter; Ko, In Soo; Ko, Kwok; Kobayashi, Makoto; Kobayashi, Nobuko; Kobel, Michael; Koch, Manuel; Kodys, Peter; Koetz, Uli; Kohrs, Robert; Kojima, Yuuji; Kolanoski, Hermann; Kolodziej, Karol; Kolomensky, Yury G.; Komamiya, Sachio; Kong, Xiang Cheng; Konigsberg, Jacobo; Korbel, Volker; Koscielniak, Shane; Kostromin, Sergey; Kowalewski, Robert; Kraml, Sabine; Krammer, Manfred; Krasnykh, Anatoly; Krautscheid, Thorsten; Krawczyk, Maria; James Krebs, H.; Krempetz, Kurt; Kribs, Graham; Krishnagopal, Srinivas; Kriske, Richard; Kronfeld, Andreas; Kroseberg, Jürgen; Kruchonak, Uladzimir; Kruecker, Dirk; Krüger, Hans; Krumpa, Nicholas A.; Krumshtein, Zinovii; Kuang, Yu Ping; Kubo, Kiyoshi; Kuchler, Vic; Kudoh, Noboru; Kulis, Szymon; Kumada, Masayuki; Kumar, Abhay; Kume, Tatsuya; Kundu, Anirban; Kurevlev, German; Kurihara, Yoshimasa; Kuriki, Masao; Kuroda, Shigeru; Kuroiwa, Hirotoshi; Kurokawa, Shin-ichi; Kusano, Tomonori; Kush, Pradeep K.; Kutschke, Robert; Kuznetsova, Ekaterina; Kvasnicka, Peter; Kwon, Youngjoon; Labarga, Luis; Lacasta, Carlos; Lackey, Sharon; Lackowski, Thomas W.; Lafaye, Remi; Lafferty, George; Lagorio, Eric; Laktineh, Imad; Lal, Shankar; Laloum, Maurice; Lam, Briant; Lancaster, Mark; Lander, Richard; Lange, Wolfgang; Langenfeld, Ulrich; Langeveld, Willem; Larbalestier, David; Larsen, Ray; Lastovicka, Tomas; Lastovicka-Medin, Gordana; Latina, Andrea; Latour, Emmanuel; Laurent, Lisa; Le, Ba Nam; Le, Duc Ninh; Le Diberder, Francois; Dû, Patrick Le; Lebbolo, Hervé; Lebrun, Paul; Lecoq, Jacques; Lee, Sung-Won; Lehner, Frank; Leibfritz, Jerry; Lenkszus, Frank; Lesiak, Tadeusz; Levy, Aharon; Lewandowski, Jim; Leyh, Greg; Li, Cheng; Li, Chong Sheng; Li, Chun Hua; Li, Da Zhang; Li, Gang; Li, Jin; Li, Shao Peng; Li, Wei Ming; Li, Weiguo; Li, Xiao Ping; Li, Xue-Qian; Li, Yuanjing; Li, Yulan; Li, Zenghai; Li, Zhong Quan; Liang, Jian Tao; Liao, Yi; Lilje, Lutz; Guilherme Lima, J.; Lintern, Andrew J.; Lipton, Ronald; List, Benno; List, Jenny; Liu, Chun; Liu, Jian Fei; Liu, Ke Xin; Liu, Li Qiang; Liu, Shao Zhen; Liu, Sheng Guang; Liu, Shubin; Liu, Wanming; Liu, Wei Bin; Liu, Ya Ping; Liu, Yu Dong; Lockyer, Nigel; Logan, Heather E.; Logatchev, Pavel V.; Lohmann, Wolfgang; Lohse, Thomas; Lola, Smaragda; Lopez-Virto, Amparo; Loveridge, Peter; Lozano, Manuel; Lu, Cai-Dian; Lu, Changguo; Lu, Gong-Lu; Lu, Wen Hui; Lubatti, Henry; Lucotte, Arnaud; Lundberg, Björn; Lundin, Tracy; Luo, Mingxing; Luong, Michel; Luth, Vera; Lutz, Benjamin; Lutz, Pierre; Lux, Thorsten; Luzniak, Pawel; Lyapin, Alexey; Lykken, Joseph; Lynch, Clare; Ma, Li; Ma, Lili; Ma, Qiang; Ma, Wen-Gan; Macfarlane, David; Maciel, Arthur; MacLeod, Allan; MacNair, David; Mader, Wolfgang; Magill, Stephen; Magnan, Anne-Marie; Maiheu, Bino; Maity, Manas; Majchrzak, Millicent; Majumder, Gobinda; Makarov, Roman; Makowski, Dariusz; Malaescu, Bogdan; Mallik, C.; Mallik, Usha; Malton, Stephen; Malyshev, Oleg B.; Malysheva, Larisa I.; Mammosser, John; Mamta; Mamuzic, Judita; Manen, Samuel; Manghisoni, Massimo; Manly, Steven; Marcellini, Fabio; Marcisovsky, Michal; Markiewicz, Thomas W.; Marks, Steve; Marone, Andrew; Marti, Felix; Martin, Jean-Pierre; Martin, Victoria; Martin-Chassard, Gisèle; Martinez, Manel; Martinez-Rivero, Celso; Martsch, Dennis; Martyn, Hans-Ulrich; Maruyama, Takashi; Masuzawa, Mika; Mathez, Hervé; Matsuda, Takeshi; Matsumoto, Hiroshi; Matsumoto, Shuji; Matsumoto, Toshihiro; Matsunaga, Hiroyuki; Mättig, Peter; Mattison, Thomas; Mavromanolakis, Georgios; Mawatari, Kentarou; Mazzacane, Anna; McBride, Patricia; McCormick, Douglas; McCormick, Jeremy; McDonald, Kirk T.; McGee, Mike; McIntosh, Peter; McKee, Bobby; McPherson, Robert A.; Meidlinger, Mandi; Meier, Karlheinz; Mele, Barbara; Meller, Bob; Melzer-Pellmann, Isabell-Alissandra; Mendez, Hector; Mercer, Adam; Merkin, Mikhail; Meshkov, I.N.; Messner, Robert; Metcalfe, Jessica; Meyer, Chris; Meyer, Hendrik; Meyer, Joachim; Meyer, Niels; Meyners, Norbert; Michelato, Paolo; Michizono, Shinichiro; Mihalcea, Daniel; Mihara, Satoshi; Mihara, Takanori; Mikami, Yoshinari; Mikhailichenko, Alexander A.; Milardi, Catia; Miller, David J.; Miller, Owen; Miller, Roger J.; Milstene, Caroline; Mimashi, Toshihiro; Minashvili, Irakli; Miquel, Ramon; Mishra, Shekhar; Mitaroff, Winfried; Mitchell, Chad; Miura, Takako; Miyamoto, Akiya; Miyata, Hitoshi; Mjörnmark, Ulf; Mnich, Joachim; Moenig, Klaus; Moffeit, Kenneth; Mokhov, Nikolai; Molloy, Stephen; Monaco, Laura; Monasterio, Paul R.; Montanari, Alessandro; Moon, Sung Ik; Moortgat-Pick, Gudrid A.; Mora de Freitas, Paulo; Morel, Federic; Moretti, Stefano; Morgunov, Vasily; Mori, Toshinori; Morin, Laurent; Morisseau, François; Morita, Yoshiyuki; Morita, Youhei; Morita, Yuichi; Morozov, Nikolai; Morozumi, Yuichi; Morse, William; Moser, Hans-Guenther; Moultaka, Gilbert; Mtingwa, Sekazi; Mudrinic, Mihajlo; Mueller, Alex; Mueller, Wolfgang; Muennich, Astrid; Muhlleitner, Milada Margarete; Mukherjee, Bhaskar; Mukhopadhyaya, Biswarup; Müller, Thomas; Munro, Morrison; Murayama, Hitoshi; Muto, Toshiya; Myneni, Ganapati Rao; Nabhiraj, P.Y.; Nagaitsev, Sergei; Nagamine, Tadashi; Nagano, Ai; Naito, Takashi; Nakai, Hirotaka; Nakajima, Hiromitsu; Nakamura, Isamu; Nakamura, Tomoya; Nakanishi, Tsutomu; Nakao, Katsumi; Nakao, Noriaki; Nakayoshi, Kazuo; Nam, Sang; Namito, Yoshihito; Namkung, Won; Nantista, Chris; Napoly, Olivier; Narain, Meenakshi; Naroska, Beate; Nauenberg, Uriel; Nayyar, Ruchika; Neal, Homer; Nelson, Charles; Nelson, Janice; Nelson, Timothy; Nemecek, Stanislav; Neubauer, Michael; Neuffer, David; Newman, Myriam Q.; Nezhevenko, Oleg; Ng, Cho-Kuen; Nguyen, Anh Ky; Nguyen, Minh; Van Nguyen Thi,Hong; Niebuhr, Carsten; Niehoff, Jim; Niezurawski, Piotr; Nishitani, Tomohiro; Nitoh, Osamu; Noguchi, Shuichi; Nomerotski, Andrei; Noonan, John; Norbeck, Edward; Nosochkov, Yuri; Notz, Dieter; Nowak, Grazyna; Nowak, Hannelies; Noy, Matthew; Nozaki, Mitsuaki; Nyffeler, Andreas; Nygren, David; Oddone, Piermaria; O'Dell, Joseph; Oh, Jong-Seok; Oh, Sun Kun; Ohkuma, Kazumasa; Ohlerich, Martin; Ohmi, Kazuhito; Ohnishi, Yukiyoshi; Ohsawa, Satoshi; Ohuchi, Norihito; Oide, Katsunobu; Okada, Nobuchika; Okamura, Takahiro; Okugi, Toshiyuki; Okumi, Shoji; Okumura, Ken-ichi; Olchevski, Alexander; Oliver, William; Olivier, Bob; Olsen, James; Olsen, Jeff; Olsen, Stephen; Olshevsky, A.G.; Olsson, Jan; Omori, Tsunehiko; Onel, Yasar; Onengut, Gulsen; Ono, Hiroaki; Onoprienko, Dmitry; Oreglia, Mark; Oren, Will; Orimoto, Toyoko J.; Oriunno, Marco; Orlandea, Marius Ciprian; Oroku, Masahiro; Orr, Lynne H.; Orr, Robert S.; Oshea, Val; Oskarsson, Anders; Osland, Per; Ossetski, Dmitri; Österman, Lennart; Ostiguy, Francois; Otono, Hidetoshi; Ottewell, Brian; Ouyang, Qun; Padamsee, Hasan; Padilla, Cristobal; Pagani, Carlo; Palmer, Mark A.; Pam, Wei Min; Pande, Manjiri; Pande, Rajni; Pandit, V.S.; Pandita, P.N.; Pandurovic, Mila; Pankov, Alexander; Panzeri, Nicola; Papandreou, Zisis; Paparella, Rocco; Para, Adam; Park, Hwanbae; Parker, Brett; Parkes, Chris; Parma, Vittorio; Parsa, Zohreh; Parsons, Justin; Partridge, Richard; Pasquinelli, Ralph; Pásztor, Gabriella; Paterson, Ewan; Patrick, Jim; Patteri, Piero; Ritchie Patterson, J.; Pauletta, Giovanni; Paver, Nello; Pavlicek, Vince; Pawlik, Bogdan; Payet, Jacques; Pchalek, Norbert; Pedersen, John; Pei, Guo Xi; Pei, Shi Lun; Pelka, Jerzy; Pellegrini, Giulio; Pellett, David; Peng, G.X.; Penn, Gregory; Penzo, Aldo; Perry, Colin; Peskin, Michael; Peters, Franz; Petersen, Troels Christian; Peterson, Daniel; Peterson, Thomas; Petterson, Maureen; Pfeffer, Howard; Pfund, Phil; Phelps, Alan; Van Phi, Quang; Phillips, Jonathan; Phinney, Nan; Piccolo, Marcello; Piemontese, Livio; Pierini, Paolo; Thomas Piggott, W.; Pike, Gary; Pillet, Nicolas; Jayawardena, Talini Pinto; Piot, Phillippe; Pitts, Kevin; Pivi, Mauro; Plate, Dave; Pleier, Marc-Andre; Poblaguev, Andrei; Poehler, Michael; Poelker, Matthew; Poffenberger, Paul; Pogorelsky, Igor; Poirier, Freddy; Poling, Ronald; Poole, Mike; Popescu, Sorina; Popielarski, John; Pöschl, Roman; Postranecky, Martin; Potukochi, Prakash N.; Prast, Julie; Prat, Serge; Preger, Miro; Prepost, Richard; Price, Michael; Proch, Dieter; Puntambekar, Avinash; Qin, Qing; Qu, Hua Min; Quadt, Arnulf; Quesnel, Jean-Pierre; Radeka, Veljko; Rahmat, Rahmat; Rai, Santosh Kumar; Raimondi, Pantaleo; Ramberg, Erik; Ranjan, Kirti; Rao, Sista V.L.S.; Raspereza, Alexei; Ratti, Alessandro; Ratti, Lodovico; Raubenheimer, Tor; Raux, Ludovic; Ravindran, V.; Raychaudhuri, Sreerup; Re, Valerio; Rease, Bill; Reece, Charles E.; Regler, Meinhard; Rehlich, Kay; Reichel, Ina; Reichold, Armin; Reid, John; Reid, Ron; Reidy, James; Reinhard, Marcel; Renz, Uwe; Repond, Jose; Resta-Lopez, Javier; Reuen, Lars; Ribnik, Jacob; Rice, Tyler; Richard, François; Riemann, Sabine; Riemann, Tord; Riles, Keith; Riley, Daniel; Rimbault, Cécile; Rindani, Saurabh; Rinolfi, Louis; Risigo, Fabio; Riu, Imma; Rizhikov, Dmitri; Rizzo, Thomas; Rochford, James H.; Rodriguez, Ponciano; Roeben, Martin; Rolandi, Gigi; Roodman, Aaron; Rosenberg, Eli; Roser, Robert; Ross, Marc; Rossel, François; Rossmanith, Robert; Roth, Stefan; Rougé, André; Rowe, Allan; Roy, Amit; Roy, Sendhunil B.; Roy, Sourov; Royer, Laurent; Royole-Degieux, Perrine; Royon, Christophe; Ruan, Manqi; Rubin, David; Ruehl, Ingo; Jimeno, Alberto Ruiz; Ruland, Robert; Rusnak, Brian; Ryu, Sun-Young; Sabbi, Gian Luca; Sadeh, Iftach; Sadygov, Ziraddin Y; Saeki, Takayuki; Sagan, David; Sahni, Vinod C.; Saini, Arun; Saito, Kenji; Saito, Kiwamu; Sajot, Gerard; Sakanaka, Shogo; Sakaue, Kazuyuki; Salata, Zen; Salih, Sabah; Salvatore, Fabrizio; Samson, Joergen; Sanami, Toshiya; Levi Sanchez, Allister; Sands, William; Santic, John; Sanuki, Tomoyuki; Sapronov, Andrey; Sarkar, Utpal; Sasao, Noboru; Satoh, Kotaro; Sauli, Fabio; Saunders, Claude; Saveliev, Valeri; Savoy-Navarro, Aurore; Sawyer, Lee; Saxton, Laura; Schäfer, Oliver; Schälicke, Andreas; Schade, Peter; Schaetzel, Sebastien; Scheitrum, Glenn; Schibler, Emilie; Schindler, Rafe; Schlösser, Markus; Schlueter, Ross D.; Schmid, Peter; Schmidt, Ringo Sebastian; Schneekloth, Uwe; Schreiber, Heinz Juergen; Schreiber, Siegfried; Schroeder, Henning; Peter Schüler, K.; Schulte, Daniel; Schultz-Coulon, Hans-Christian; Schumacher, Markus; Schumann, Steffen; Schumm, Bruce A.; Schwienhorst, Reinhard; Schwierz, Rainer; Scott, Duncan J.; Scuri, Fabrizio; Sefkow, Felix; Sefri, Rachid; Seguin-Moreau, Nathalie; Seidel, Sally; Seidman, David; Sekmen, Sezen; Seletskiy, Sergei; Senaha, Eibun; Senanayake, Rohan; Sendai, Hiroshi; Sertore, Daniele; Seryi, Andrei; Settles, Ronald; Sever, Ramazan; Shales, Nicholas; Shao, Ming; Shelkov, G.A.; Shepard, Ken; Shepherd-Themistocleous, Claire; Sheppard, John C.; Shi, Cai Tu; Shidara, Tetsuo; Shim, Yeo-Jeong; Shimizu, Hirotaka; Shimizu, Yasuhiro; Shimizu, Yuuki; Shimogawa, Tetsushi; Shin, Seunghwan; Shioden, Masaomi; Shipsey, Ian; Shirkov, Grigori; Shishido, Toshio; Shivpuri, Ram K.; Shrivastava, Purushottam; Shulga, Sergey; Shumeiko, Nikolai; Shuvalov, Sergey; Si, Zongguo; Siddiqui, Azher Majid; Siegrist, James; Simon, Claire; Simrock, Stefan; Sinev, Nikolai; Singh, Bhartendu K.; Singh, Jasbir; Singh, Pitamber; Singh, R.K.; Singh, S.K.; Singini, Monito; Sinha, Anil K.; Sinha, Nita; Sinha, Rahul; Sinram, Klaus; Sissakian, A.N.; Skachkov, N.B.; Skrinsky, Alexander; Slater, Mark; Slominski, Wojciech; Smiljanic, Ivan; Smith, A J Stewart; Smith, Alex; Smith, Brian J.; Smith, Jeff; Smith, Jonathan; Smith, Steve; Smith, Susan; Smith, Tonee; Neville Snodgrass, W.; Sobloher, Blanka; Sohn, Young-Uk; Solidum, Ruelson; Solyak, Nikolai; Son, Dongchul; Sonmez, Nasuf; Sopczak, Andre; Soskov, V.; Spencer, Cherrill M.; Spentzouris, Panagiotis; Speziali, Valeria; Spira, Michael; Sprehn, Daryl; Sridhar, K.; Srivastava, Asutosh; St. Lorant, Steve; Stahl, Achim; Stanek, Richard P.; Stanitzki, Marcel; Stanley, Jacob; Stefanov, Konstantin; Stein, Werner; Steiner, Herbert; Stenlund, Evert; Stern, Amir; Sternberg, Matt; Stockinger, Dominik; Stockton, Mark; Stoeck, Holger; Strachan, John; Strakhovenko, V.; Strauss, Michael; Striganov, Sergei I.; Strologas, John; Strom, David; Strube, Jan; Stupakov, Gennady; Su, Dong; Sudo, Yuji; Suehara, Taikan; Suehiro, Toru; Suetsugu, Yusuke; Sugahara, Ryuhei; Sugimoto, Yasuhiro; Sugiyama, Akira; Suh, Jun Suhk; Sukovic, Goran; Sun, Hong; Sun, Stephen; Sun, Werner; Sun, Yi; Sun, Yipeng; Suszycki, Leszek; Sutcliffe, Peter; Suthar, Rameshwar L.; Suwada, Tsuyoshi; Suzuki, Atsuto; Suzuki, Chihiro; Suzuki, Shiro; Suzuki, Takashi; Swent, Richard; Swientek, Krzysztof; Swinson, Christina; Syresin, Evgeny; Szleper, Michal; Tadday, Alexander; Takahashi, Rika; Takahashi, Tohru; Takano, Mikio; Takasaki, Fumihiko; Takeda, Seishi; Takenaka, Tateru; Takeshita, Tohru; Takubo, Yosuke; Tanaka, Masami; Tang, Chuan Xiang; Taniguchi, Takashi; Tantawi, Sami; Tapprogge, Stefan; Tartaglia, Michael A.; Tassielli, Giovanni Francesco; Tauchi, Toshiaki; Tavian, Laurent; Tawara, Hiroko; Taylor, Geoffrey; Telnov, Alexandre V.; Telnov, Valery; Tenenbaum, Peter; Teodorescu, Eliza; Terashima, Akio; Terracciano, Giuseppina; Terunuma, Nobuhiro; Teubner, Thomas; Teuscher, Richard; Theilacker, Jay; Thomson, Mark; Tice, Jeff; Tigner, Maury; Timmermans, Jan; Titov, Maxim; Toge, Nobukazu; Tokareva, N.A.; Tollefson, Kirsten; Tomasek, Lukas; Tomovic, Savo; Tompkins, John; Tonutti, Manfred; Topkar, Anita; Toprek, Dragan; Toral, Fernando; Torrence, Eric; Traversi, Gianluca; Trimpl, Marcel; Mani Tripathi, S.; Trischuk, William; Trodden, Mark; Trubnikov, G.V.; Tschirhart, Robert; Tskhadadze, Edisher; Tsuchiya, Kiyosumi; Tsukamoto, Toshifumi; Tsunemi, Akira; Tucker, Robin; Turchetta, Renato; Tyndel, Mike; Uekusa, Nobuhiro; Ueno, Kenji; Umemori, Kensei; Ummenhofer, Martin; Underwood, David; Uozumi, Satoru; Urakawa, Junji; Urban, Jeremy; Uriot, Didier; Urner, David; Ushakov, Andrei; Usher, Tracy; Uzunyan, Sergey; Vachon, Brigitte; Valerio, Linda; Valin, Isabelle; Valishev, Alex; Vamra, Raghava; Van der Graaf, Harry; Van Kooten, Rick; Van Zandbergen, Gary; Vanel, Jean-Charles; Variola, Alessandro; Varner, Gary; Velasco, Mayda; Velte, Ulrich; Velthuis, Jaap; Vempati, Sundir K.; Venturini, Marco; Vescovi, Christophe; Videau, Henri; Vila, Ivan; Vincent, Pascal; Virey, Jean-Marc; Visentin, Bernard; Viti, Michele; Vo, Thanh Cuong; Vogel, Adrian; Vogt, Harald; von Toerne, Eckhard; Vorozhtsov, S.B.; Vos, Marcel; Votava, Margaret; Vrba, Vaclav; Wackeroth, Doreen; Wagner, Albrecht; Wagner, Carlos E.M.; Wagner, Stephen; Wake, Masayoshi; Walczak, Roman; Walkowiak, Wolfgang; Wallon, Samuel; Walsh, Roberval; Walston, Sean; Waltenberger, Wolfgang; Walz, Dieter; Wang, Chao En; Wang, Chun Hong; Wang, Dou; Wang, Faya; Wang, Guang Wei; Wang, Haitao; Wang, Jiang; Wang, Jiu Qing; Wang, Juwen; Wang, Lanfa; Wang, Lei; Wang, Min-Zu; Wang, Qing; Wang, Shu Hong; Wang, Xiaolian; Wang, Xue-Lei; Wang, Yi Fang; Wang, Zheng; Wanzenberg, Rainer; Ward, Bennie; Ward, David; Warmbein, Barbara; Warner, David W.; Warren, Matthew; Washio, Masakazu; Watanabe, Isamu; Watanabe, Ken; Watanabe, Takashi; Watanabe, Yuichi; Watson, Nigel; Wattimena, Nanda; Wayne, Mitchell; Weber, Marc; Weerts, Harry; Weiglein, Georg; Weiland, Thomas; Weinzierl, Stefan; Weise, Hans; Weisend, John; Wendt, Manfred; Wendt, Oliver; Wenzel, Hans; Wenzel, William A.; Wermes, Norbert; Werthenbach, Ulrich; Wesseln, Steve; Wester, William; White, Andy; White, Glen R.; Wichmann, Katarzyna; Wienemann, Peter; Wierba, Wojciech; Wilksen, Tim; Willis, William; Wilson, Graham W.; Wilson, John A.; Wilson, Robert; Wing, Matthew; Winter, Marc; Wirth, Brian D.; Wolbers, Stephen A.; Wolff, Dan; Wolski, Andrzej; Woodley, Mark D.; Woods, Michael; Woodward, Michael L.; Woolliscroft, Timothy; Worm, Steven; Wormser, Guy; Wright, Dennis; Wright, Douglas; Wu, Andy; Wu, Tao; Wu, Yue Liang; Xella, Stefania; Xia, Guoxing; Xia, Lei; Xiao, Aimin; Xiao, Liling; Xie, Jia Lin; Xing, Zhi-Zhong; Xiong, Lian You; Xu, Gang; Xu, Qing Jing; Yajnik, Urjit A.; Yakimenko, Vitaly; Yamada, Ryuji; Yamaguchi, Hiroshi; Yamamoto, Akira; Yamamoto, Hitoshi; Yamamoto, Masahiro; Yamamoto, Naoto; Yamamoto, Richard; Yamamoto, Yasuchika; Yamanaka, Takashi; Yamaoka, Hiroshi; Yamashita, Satoru; Yamazaki, Hideki; Yan, Wenbiao; Yang, Hai-Jun; Yang, Jin Min; Yang, Jongmann; Yang, Zhenwei; Yano, Yoshiharu; Yazgan, Efe; Yeh, G.P.; Yilmaz, Hakan; Yock, Philip; Yoda, Hakutaro; Yoh, John; Yokoya, Kaoru; Yokoyama, Hirokazu; York, Richard C.; Yoshida, Mitsuhiro; Yoshida, Takuo; Yoshioka, Tamaki; Young, Andrew; Yu, Cheng Hui; Yu, Jaehoon; Yu, Xian Ming; Yuan, Changzheng; Yue, Chong-Xing; Yue, Jun Hui; Zacek, Josef; Zagorodnov, Igor; Zalesak, Jaroslav; Zalikhanov, Boris; Zarnecki, Aleksander Filip; Zawiejski, Leszek; Zeitnitz, Christian; Zeller, Michael; Zerwas, Dirk; Zerwas, Peter; Zeyrek, Mehmet; Zhai, Ji Yuan; Zhang, Bao Cheng; Zhang, Bin; Zhang, Chuang; Zhang, He; Zhang, Jiawen; Zhang, Jing; Zhang, Jing Ru; Zhang, Jinlong; Zhang, Liang; Zhang, X.; Zhang, Yuan; Zhang, Zhige; Zhang, Zhiqing; Zhang, Ziping; Zhao, Haiwen; Zhao, Ji Jiu; Zhao, Jing Xia; Zhao, Ming Hua; Zhao, Sheng Chu; Zhao, Tianchi; Zhao, Tong Xian; Zhao, Zhen Tang; Zhao, Zhengguo; Zhou, De Min; Zhou, Feng; Zhou, Shun; Zhu, Shou Hua; Zhu, Xiong Wei; Zhukov, Valery; Zimmermann, Frank; Ziolkowski, Michael; Zisman, Michael S.; Zomer, Fabian; Zong, Zhang Guo; Zorba, Osman; Zutshi, Vishnu

    2007-01-01

    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.

  10. TECHNOLOGY EVALUATION REPORT, SITE PROGRAM DEMONSTRATION TEST: SHIRCO PILOT-SCALE INFRARED INCINERATION SYSTEM ROSE TOWNSHIP DEMODE ROAD SUPERFUND SITE - VOLUME II

    Science.gov (United States)

    The performance of the Shirco pilot-scale infrared thermal destruction system has been evaluated at the Rose Township, Demode Road Superfund Site and is presented in the report. The waste tested consisted of solvents, organics and heavy metals in an illegal dump site. Volume I gi...

  11. Standard surgical treatment for benign prostatic hyperplasia is safe for patients over 75 years: analysis of 100 cases from a high-volume urologic center

    Directory of Open Access Journals (Sweden)

    Rafael Marmiroli

    2012-12-01

    Full Text Available OBJECTIVES: In this study, we aimed to determine the complications of standard surgical treatments among patients over 75 years in a high-volume urologic center. METHODS: We analyzed 100 consecutive patients older than 75 years who had undergone transurethral prostatic resection of the prostate or open prostatectomy for treatment of benign prostatic hyperplasia from January 2008 to March 2010. We analyzed patient age, prostate volume, prostate-specific antigen level, international prostatic symptom score, quality of life score, urinary retention, co-morbidities, surgical technique and satisfaction with treatment. RESULTS: Median age was 79 years. Forty-eight patients had undergone transurethral prostatic resection of the prostate, and 52 had undergone open prostatectomy. The median International Prostatic Symptom Score was 20, the median prostate volume was 83 g, 51% were using an indwelling bladder catheter, and the median prostatespecific antigen level was 5.0 ng/ml. The most common comorbidities were hypertension, diabetes and coronary disease. After a median follow-up period of 17 months, most patients were satisfied. Complications were present in 20% of cases. The most common urological complication was urethral stenosis, followed by bladder neck sclerosis, urinary fistula, late macroscopic hematuria and persistent urinary incontinence. The most common clinical complication was myocardial infarction, followed by acute renal failure requiring dialysis. Incidental carcinoma of the prostate was present in 6% of cases. One case had urothelial bladder cancer. CONCLUSIONS: Standard surgical treatments for benign prostatic hyperplasia are safe and satisfactory among the elderly. Complications are infrequent, and urethral stenosis is the most common. No clinical variable is associated with the occurrence of complications.

  12. Macular thickness and macular volume measurements using spectral domain optical coherence tomography in normal Nepalese eyes

    Directory of Open Access Journals (Sweden)

    Pokharel A

    2016-03-01

    Full Text Available Amrit Pokharel,1 Gauri Shankar Shrestha,2 Jyoti Baba Shrestha2 1Department of Ophthalmology, Kathmandu Medical College Teaching Hospital, 2B P Koirala Lions Centre for Ophthalmic Studies, Institute of Medicine, Kathmandu, Nepal Purpose: To record the normative values for macular thickness and macular volume in normal Nepalese eyes. Methods: In all, 126 eyes of 63 emmetropic subjects (mean age: 21.17±6.76 years; range: 10–37 years were assessed for macular thickness and macular volume, using spectral domain-optical coherence tomography over 6×6 mm2 in the posterior pole. A fast macular thickness protocol was employed. Statistics such as the mean, median, standard deviation, percentiles, and range were used, while a P-value was set at 0.05 to test significance. Results: Average macular thickness and total macular volume were larger in males compared to females. With each year of increasing age, these variables decreased by 0.556 µm and 0.0156 mm3 for average macular thickness and total macular volume, respectively. The macular thickness was greatest in the inner superior section and lowest at the center of the fovea. The volume was greatest in the outer nasal section and thinnest in the fovea. The central subfield thickness (r=-0.243, P=0.055 and foveal volume (r=0.216, P=0.09 did not correlate with age. Conclusion: Males and females differ significantly with regard to macular thickness and macular volume measurements. Reports by other studies that the increase in axial length reduced thickness and volume, were negated by this study which found a positive correlation among axial length, thickness, and volume. Keywords: macular thickness, macular volume, optical coherence tomography, Nepal

  13. Human Factors Process Task Analysis Liquid Oxygen Pump Acceptance Test Procedure for the Advanced Technology Development Center

    Science.gov (United States)

    Diorio, Kimberly A.

    2002-01-01

    A process task analysis effort was undertaken by Dynacs Inc. commencing in June 2002 under contract from NASA YA-D6. Funding was provided through NASA's Ames Research Center (ARC), Code M/HQ, and Industrial Engineering and Safety (IES). The John F. Kennedy Space Center (KSC) Engineering Development Contract (EDC) Task Order was 5SMA768. The scope of the effort was to conduct a Human Factors Process Failure Modes and Effects Analysis (HF PFMEA) of a hazardous activity and provide recommendations to eliminate or reduce the effects of errors caused by human factors. The Liquid Oxygen (LOX) Pump Acceptance Test Procedure (ATP) was selected for this analysis. The HF PFMEA table (see appendix A) provides an analysis of six major categories evaluated for this study. These categories include Personnel Certification, Test Procedure Format, Test Procedure Safety Controls, Test Article Data, Instrumentation, and Voice Communication. For each specific requirement listed in appendix A, the following topics were addressed: Requirement, Potential Human Error, Performance-Shaping Factors, Potential Effects of the Error, Barriers and Controls, Risk Priority Numbers, and Recommended Actions. This report summarizes findings and gives recommendations as determined by the data contained in appendix A. It also includes a discussion of technology barriers and challenges to performing task analyses, as well as lessons learned. The HF PFMEA table in appendix A recommends the use of accepted and required safety criteria in order to reduce the risk of human error. The items with the highest risk priority numbers should receive the greatest amount of consideration. Implementation of the recommendations will result in a safer operation for all personnel.

  14. Analysis of the forced vibration test of the Hualien large scale soil-structure interaction model using a flexible volume substructuring method

    International Nuclear Information System (INIS)

    Tang, H.T.; Nakamura, N.

    1995-01-01

    A 1/4-scale cylindrical reactor containment model was constructed in Hualien, Taiwan for foil-structure interaction (SSI) effect evaluation and SSI analysis procedure verification. Forced vibration tests were executed before backfill (FVT-1) and after backfill (FVT-2) to characterize soil-structure system characteristics under low excitations. A number of organizations participated in the pre-test blind prediction and post-test correlation analyses of the forced vibration test using various industry familiar methods. In the current study, correlation analyses were performed using a three-dimensional flexible volume substructuring method. The results are reported and soil property sensitivities are evaluated in the paper. (J.P.N.)

  15. Index to Nuclear Safety: a technical progress review by chrology, permuted title, and author, Volume 11(1) through Volume 20(6)

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W B; Passiakos, M

    1980-06-01

    This index to Nuclear Safety, a bimonthly technical progress review, covers articles published in Nuclear Safety, Volume II, No. 1 (January-February 1970), through Volume 20, No. 6 (November-December 1979). It is divided into three sections: a chronological list of articles (including abstracts) followed by a permuted-title (KWIC) index and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center (NSIC), covers all safety aspects of nuclear power reactors and associated facilities. Over 600 technical articles published in Nuclear Safety in the last ten years are listed in this index.

  16. Fusion Engineering Device. Volume II. Design description

    International Nuclear Information System (INIS)

    1981-10-01

    This volume summarizes the design of the FED. It includes a description of the major systems and subsystems, the supporting plasma design analysis, a projected device cost and associated construction schedule, and a description of the facilities to house and support the device. This effort represents the culmination of the FY81 studies conducted at the Fusion Engineering Design Center (FEDC). Unique in these design activities has been the collaborative involvement of the Design Center personnel and numerous resource physicists from the fusion community who have made significant contributions in the physics design analysis as well as the physics support of the engineering design of the major FED systems and components

  17. Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1

    International Nuclear Information System (INIS)

    1994-07-01

    The 1994 Symposium on Valve and Pump Testing, jointly sponsored by the Board of Nuclear Codes and Standards of the American Society of Mechanical Engineers and by the Nuclear Regulatory Commission, provides a forum for the discussion of current programs and methods for inservice testing and motor-operated valve testing at nuclear power plants. The symposium also provides an opportunity to discuss the need to improve that testing in order to help ensure the reliable performance of pumps and valves. The participation of industry representatives, regulators, and consultants results in the discussion of a broad spectrum of ideas and perspectives regarding the improvement of inservice testing of pumps and valves at nuclear power plants. This document, Volume 1, covers sessions 1A through session 2C. The individual papers have been cataloged separately

  18. Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 Symposium on Valve and Pump Testing, jointly sponsored by the Board of Nuclear Codes and Standards of the American Society of Mechanical Engineers and by the Nuclear Regulatory Commission, provides a forum for the discussion of current programs and methods for inservice testing and motor-operated valve testing at nuclear power plants. The symposium also provides an opportunity to discuss the need to improve that testing in order to help ensure the reliable performance of pumps and valves. The participation of industry representatives, regulators, and consultants results in the discussion of a broad spectrum of ideas and perspectives regarding the improvement of inservice testing of pumps and valves at nuclear power plants. This document, Volume 1, covers sessions 1A through session 2C. The individual papers have been cataloged separately.

  19. A novel finite volume discretization method for advection-diffusion systems on stretched meshes

    Science.gov (United States)

    Merrick, D. G.; Malan, A. G.; van Rooyen, J. A.

    2018-06-01

    This work is concerned with spatial advection and diffusion discretization technology within the field of Computational Fluid Dynamics (CFD). In this context, a novel method is proposed, which is dubbed the Enhanced Taylor Advection-Diffusion (ETAD) scheme. The model equation employed for design of the scheme is the scalar advection-diffusion equation, the industrial application being incompressible laminar and turbulent flow. Developed to be implementable into finite volume codes, ETAD places specific emphasis on improving accuracy on stretched structured and unstructured meshes while considering both advection and diffusion aspects in a holistic manner. A vertex-centered structured and unstructured finite volume scheme is used, and only data available on either side of the volume face is employed. This includes the addition of a so-called mesh stretching metric. Additionally, non-linear blending with the existing NVSF scheme was performed in the interest of robustness and stability, particularly on equispaced meshes. The developed scheme is assessed in terms of accuracy - this is done analytically and numerically, via comparison to upwind methods which include the popular QUICK and CUI techniques. Numerical tests involved the 1D scalar advection-diffusion equation, a 2D lid driven cavity and turbulent flow case. Significant improvements in accuracy were achieved, with L2 error reductions of up to 75%.

  20. Probability distribution of machining center failures

    International Nuclear Information System (INIS)

    Jia Yazhou; Wang Molin; Jia Zhixin

    1995-01-01

    Through field tracing research for 24 Chinese cutter-changeable CNC machine tools (machining centers) over a period of one year, a database of operation and maintenance for machining centers was built, the failure data was fitted to the Weibull distribution and the exponential distribution, the effectiveness was tested, and the failure distribution pattern of machining centers was found. Finally, the reliability characterizations for machining centers are proposed

  1. Transportation management center data capture for performance and mobility measures guidebook.

    Science.gov (United States)

    2013-03-01

    The Guide to Transportation Management Center (TMC) Data Capture for Performance and Mobility Measures is a two-volume document consisting of this summary Guidebook and a Reference Manual. These documents provide technical guidance and recommended pr...

  2. Demonstration, testing, & evaluation of in situ heating of soil. Draft final report, Volume II: Appendices A to E

    Energy Technology Data Exchange (ETDEWEB)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-02-12

    This document is a draft final report for US DOE contract entitled, {open_quotes}Demonstration Testing and Evaluation of In Situ Soil Heating,{close_quotes} Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report This document is Volume II, containing appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120{degrees}to 130{degrees}C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow.

  3. Optimizing urine drug testing for monitoring medication compliance in pain management.

    Science.gov (United States)

    Melanson, Stacy E F; Ptolemy, Adam S; Wasan, Ajay D

    2013-12-01

    It can be challenging to successfully monitor medication compliance in pain management. Clinicians and laboratorians need to collaborate to optimize patient care and maximize operational efficiency. The test menu, assay cutoffs, and testing algorithms utilized in the urine drug testing panels should be periodically reviewed and tailored to the patient population to effectively assess compliance and avoid unnecessary testing and cost to the patient. Pain management and pathology collaborated on an important quality improvement initiative to optimize urine drug testing for monitoring medication compliance in pain management. We retrospectively reviewed 18 months of data from our pain management center. We gathered data on test volumes, positivity rates, and the frequency of false positive results. We also reviewed the clinical utility of our testing algorithms, assay cutoffs, and adulterant panel. In addition, the cost of each component was calculated. The positivity rate for ethanol and 3,4-methylenedioxymethamphetamine were us to optimize our testing panel for monitoring medication compliance in pain management and reduce cost. Wiley Periodicals, Inc.

  4. Service-Learning. National Dropout Prevention Center/Network Newsletter. Volume 22, Number 4

    Science.gov (United States)

    Duckenfield, Marty, Ed.

    2011-01-01

    The "National Dropout Prevention Newsletter" is published quarterly by the National Dropout Prevention Center/Network. This issue contains the following articles: (1) Dropouts and Democracy (Robert Shumer); (2) 2011 NDPN Crystal Star Winners; (3) Service-Learning as Dropout Intervention and More (Michael VanKeulen); and (4) Teacher…

  5. Different concentrations and volumes of p-phenylenediamine in pet. (equivalent doses) are associated with similar patch test outcomes

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hamann, Carsten R; Andersen, Klaus E

    2018-01-01

    BACKGROUND: Concern about causing active sensitization when patch testing is performed with p-phenylenediamine (PPD) 1% pet. has led to a recommendation to use PPD 0.3% pet. as a potentially safer preparation. However, the dose per area of allergen delivered, and hence the risk of active...... sensitization, depend on the amount dispensed into the patch test chamber, which can vary widely. OBJECTIVE: To evaluate whether patch testing with equivalent doses of different concentrations of PPD in pet. is associated with similar outcomes. METHODS: Seventeen known PPD-sensitive subjects were patch tested...... with different volumes and concentrations of PPD in pet. that deliver the same allergen dose per unit area (6 mg of PPD 1% pet. and 20 mg of PPD 0.3% pet. in Finn Chambers®, both equivalent to ∼ 0.09 mg/cm2 ). RESULTS: Eleven patients (65%) had positive reactions to both doses; 4 patients (24%) had negative...

  6. ILC Reference Design Report Volume 3 - Accelerator

    CERN Document Server

    Phinney, Nan; Walker, Nicholas J.; Aarons, Gerald; Abe, Toshinori; Abernathy, Jason; Ablikim, Medina; Abramowicz, Halina; Adey, David; Adloff, Catherine; Adolphsen, Chris; Afanaciev, Konstantin; Agapov, Ilya; Ahn, Jung-Keun; Aihara, Hiroaki; Akemoto, Mitsuo; del Carmen Alabau, Maria; Albert, Justin; Albrecht, Hartwig; Albrecht, Michael; Alesini, David; Alexander, Gideon; Alexander, Jim; Allison, Wade; Amann, John; Amirikas, Ramila; An, Qi; Anami, Shozo; Ananthanarayan, B.; Anderson, Terry; Andricek, Ladislav; Anduze, Marc; Anerella, Michael; Anfimov, Nikolai; Angal-Kalinin, Deepa; Antipov, Sergei; Antoine, Claire; Aoki, Mayumi; Aoza, Atsushi; Aplin, Steve; Appleby, Rob; Arai, Yasuo; Araki, Sakae; Arkan, Tug; Arnold, Ned; Arnold, Ray; Arnowitt, Richard; Artru, Xavier; Arya, Kunal; Aryshev, Alexander; Asakawa, Eri; Asiri, Fred; Asner, David; Atac, Muzaffer; Atoian, Grigor; Attié, David; Augustin, Jean-Eudes; Augustine, David B.; Ayres, Bradley; Aziz, Tariq; Baars, Derek; Badaud, Frederique; Baddams, Nigel; Bagger, Jonathan; Bai, Sha; Bailey, David; Bailey, Ian R.; Baker, David; Balalykin, Nikolai I.; Balbuena, Juan Pablo; Baldy, Jean-Luc; Ball, Markus; Ball, Maurice; Ballestrero, Alessandro; Ballin, Jamie; Baltay, Charles; Bambade, Philip; Ban, Syuichi; Band, Henry; Bane, Karl; Banerjee, Bakul; Barbanotti, Serena; Barbareschi, Daniele; Barbaro-Galtieri, Angela; Barber, Desmond P.; Barbi, Mauricio; Bardin, Dmitri Y.; Barish, Barry; Barklow, Timothy L.; Barlow, Roger; Barnes, Virgil E.; Barone, Maura; Bartels, Christoph; Bartsch, Valeria; Basu, Rahul; Battaglia, Marco; Batygin, Yuri; Baudot, Jerome; Baur, Ulrich; Elwyn Baynham, D.; Beard, Carl; Bebek, Chris; Bechtle, Philip; Becker, Ulrich J.; Bedeschi, Franco; Bedjidian, Marc; Behera, Prafulla; Behnke, Ties; Bellantoni, Leo; Bellerive, Alain; Bellomo, Paul; Bentson, Lynn D.; Benyamna, Mustapha; Bergauer, Thomas; Berger, Edmond; Bergholz, Matthias; Beri, Suman; Berndt, Martin; Bernreuther, Werner; Bertolini, Alessandro; Besancon, Marc; Besson, Auguste; Beteille, Andre; Bettoni, Simona; Beyer, Michael; Bhandari, R.K.; Bharadwaj, Vinod; Bhatnagar, Vipin; Bhattacharya, Satyaki; Bhattacharyya, Gautam; Bhattacherjee, Biplob; Bhuyan, Ruchika; Bi, Xiao-Jun; Biagini, Marica; Bialowons, Wilhelm; Biebel, Otmar; Bieler, Thomas; Bierwagen, John; Birch, Alison; Bisset, Mike; Biswal, S.S.; Blackmore, Victoria; Blair, Grahame; Blanchard, Guillaume; Blazey, Gerald; Blue, Andrew; Blümlein, Johannes; Boffo, Christian; Bohn, Courtlandt; Boiko, V.I.; Boisvert, Veronique; Bondarchuk, Eduard N.; Boni, Roberto; Bonvicini, Giovanni; Boogert, Stewart; Boonekamp, Maarten; Boorman, Gary; Borras, Kerstin; Bortoletto, Daniela; Bosco, Alessio; Bosio, Carlo; Bosland, Pierre; Bosotti, Angelo; Boudry, Vincent; Boumediene, Djamel-Eddine; Bouquet, Bernard; Bourov, Serguei; Bowden, Gordon; Bower, Gary; Boyarski, Adam; Bozovic-Jelisavcic, Ivanka; Bozzi, Concezio; Brachmann, Axel; Bradshaw, Tom W.; Brandt, Andrew; Brasser, Hans Peter; Brau, Benjamin; Brau, James E.; Breidenbach, Martin; Bricker, Steve; Brient, Jean-Claude; Brock, Ian; Brodsky, Stanley; Brooksby, Craig; Broome, Timothy A.; Brown, David; Brown, David; Brownell, James H.; Bruchon, Mélanie; Brueck, Heiner; Brummitt, Amanda J.; Brun, Nicole; Buchholz, Peter; Budagov, Yulian A.; Bulgheroni, Antonio; Bulyak, Eugene; Bungau, Adriana; Bürger, Jochen; Burke, Dan; Burkhart, Craig; Burrows, Philip; Burt, Graeme; Burton, David; Büsser, Karsten; Butler, John; Butterworth, Jonathan; Buzulutskov, Alexei; Cabruja, Enric; Caccia, Massimo; Cai, Yunhai; Calcaterra, Alessandro; Caliier, Stephane; Camporesi, Tiziano; Cao, Jun-Jie; Cao, J.S.; Capatina, Ofelia; Cappellini, Chiara; Carcagno, Ruben; Carena, Marcela; Carloganu, Cristina; Carosi, Roberto; Stephen Carr, F.; Carrion, Francisco; Carter, Harry F.; Carter, John; Carwardine, John; Cassel, Richard; Cassell, Ronald; Cavallari, Giorgio; Cavallo, Emanuela; Cembranos, Jose A.R.; Chakraborty, Dhiman; Chandez, Frederic; Charles, Matthew; Chase, Brian; Chattopadhyay, Subhasis; Chauveau, Jacques; Chefdeville, Maximilien; Chehab, Robert; Chel, Stéphane; Chelkov, Georgy; Chen, Chiping; Chen, He Sheng; Chen, Huai Bi; Chen, Jia Er; Chen, Sen Yu; Chen, Shaomin; Chen, Shenjian; Chen, Xun; Chen, Yuan Bo; Cheng, Jian; Chevallier, M.; Chi, Yun Long; Chickering, William; Cho, Gi-Chol; Cho, Moo-Hyun; Choi, Jin-Hyuk; Choi, Jong Bum; Choi, Seong Youl; Choi, Young-Il; Choudhary, Brajesh; Choudhury, Debajyoti; Rai Choudhury, S.; Christian, David; Christian, Glenn; Christophe, Grojean; Chung, Jin-Hyuk; Church, Mike; Ciborowski, Jacek; Cihangir, Selcuk; Ciovati, Gianluigi; Clarke, Christine; Clarke, Don G.; Clarke, James A.; Clements, Elizabeth; Coca, Cornelia; Coe, Paul; Cogan, John; Colas, Paul; Collard, Caroline; Colledani, Claude; Combaret, Christophe; Comerma, Albert; Compton, Chris; Constance, Ben; Conway, John; Cook, Ed; Cooke, Peter; Cooper, William; Corcoran, Sean; Cornat, Rémi; Corner, Laura; Cortina Gil, Eduardo; Clay Corvin, W.; Cotta Ramusino, Angelo; Cowan, Ray; Crawford, Curtis; Cremaldi, Lucien M; Crittenden, James A.; Cussans, David; Cvach, Jaroslav; da Silva, Wilfrid; Dabiri Khah, Hamid; Dabrowski, Anne; Dabrowski, Wladyslaw; Dadoun, Olivier; Dai, Jian Ping; Dainton, John; Daly, Colin; Damerell, Chris; Danilov, Mikhail; Daniluk, Witold; Daram, Sarojini; Datta, Anindya; Dauncey, Paul; David, Jacques; Davier, Michel; Davies, Ken P.; Dawson, Sally; De Boer, Wim; De Curtis, Stefania; De Groot, Nicolo; de la Taille, Christophe; de Lira, Antonio; De Roeck, Albert; de Sangro, Riccardo; De Santis,Stefano; Deacon, Laurence; Deandrea, Aldo; Dehmelt, Klaus; Delagnes, Eric; Delahaye, Jean-Pierre; Delebecque, Pierre; Delerue, Nicholas; Delferriere, Olivier; Demarteau, Marcel; Deng, Zhi; Denisov, Yu.N.; Densham, Christopher J.; Desch, Klaus; Deshpande, Nilendra; Devanz, Guillaume; Devetak, Erik; Dexter, Amos; Di benedetto, Vito; Diéguez, Angel; Diener, Ralf; Dinh, Nguyen Dinh; Dixit, Madhu; Dixit, Sudhir; Djouadi, Abdelhak; Dolezal, Zdenek; Dollan, Ralph; Dong, Dong; Dong, Hai Yi; Dorfan, Jonathan; Dorokhov, Andrei; Doucas, George; Downing, Robert; Doyle, Eric; Doziere, Guy; Drago, Alessandro; Dragt, Alex; Drake, Gary; Drásal, Zbynek; Dreiner, Herbert; Drell, Persis; Driouichi, Chafik; Drozhdin, Alexandr; Drugakov, Vladimir; Du, Shuxian; Dugan, Gerald; Duginov, Viktor; Dulinski, Wojciech; Dulucq, Frederic; Dutta, Sukanta; Dwivedi, Jishnu; Dychkant, Alexandre; Dzahini, Daniel; Eckerlin, Guenter; Edwards, Helen; Ehrenfeld, Wolfgang; Ehrlichman, Michael; Ehrlichmann, Heiko; Eigen, Gerald; Elagin, Andrey; Elementi, Luciano; Eliasson, Peder; Ellis, John; Ellwood, George; Elsen, Eckhard; Emery, Louis; Enami, Kazuhiro; Endo, Kuninori; Enomoto, Atsushi; Eozénou, Fabien; Erbacher, Robin; Erickson, Roger; Oleg Eyser, K.; Fadeyev, Vitaliy; Fang, Shou Xian; Fant, Karen; Fasso, Alberto; Faucci Giannelli, Michele; Fehlberg, John; Feld, Lutz; Feng, Jonathan L.; Ferguson, John; Fernandez-Garcia, Marcos; Luis Fernandez-Hernando, J.; Fiala, Pavel; Fieguth, Ted; Finch, Alexander; Finocchiaro, Giuseppe; Fischer, Peter; Fisher, Peter; Eugene Fisk, H.; Fitton, Mike D.; Fleck, Ivor; Fleischer, Manfred; Fleury, Julien; Flood, Kevin; Foley, Mike; Ford, Richard; Fortin, Dominique; Foster, Brian; Fourches, Nicolas; Francis, Kurt; Frey, Ariane; Frey, Raymond; Friedsam, Horst; Frisch, Josef; Frishman, Anatoli; Fuerst, Joel; Fujii, Keisuke; Fujimoto, Junpei; Fukuda, Masafumi; Fukuda, Shigeki; Funahashi, Yoshisato; Funk, Warren; Furletova, Julia; Furukawa, Kazuro; Furuta, Fumio; Fusayasu, Takahiro; Fuster, Juan; Gadow, Karsten; Gaede, Frank; Gaglione, Renaud; Gai, Wei; Gajewski, Jan; Galik, Richard; Galkin, Alexei; Galkin, Valery; Gallin-Martel, Laurent; Gannaway, Fred; Gao, Jian She; Gao, Jie; Gao, Yuanning; Garbincius, Peter; Garcia-Tabares, Luis; Garren, Lynn; Garrido, Luís; Garutti, Erika; Garvey, Terry; Garwin, Edward; Gascón, David; Gastal, Martin; Gatto, Corrado; Gatto, Raoul; Gay, Pascal; Ge, Lixin; Ge, Ming Qi; Ge, Rui; Geiser, Achim; Gellrich, Andreas; Genat, Jean-Francois; Geng, Zhe Qiao; Gentile, Simonetta; Gerbick, Scot; Gerig, Rod; Ghosh, Dilip Kumar; Ghosh, Kirtiman; Gibbons, Lawrence; Giganon, Arnaud; Gillespie, Allan; Gillman, Tony; Ginzburg, Ilya; Giomataris, Ioannis; Giunta, Michele; Gladkikh, Peter; Gluza, Janusz; Godbole, Rohini; Godfrey, Stephen; Goldhaber, Gerson; Goldstein, Joel; Gollin, George D.; Gonzalez-Sanchez, Francisco Javier; Goodrick, Maurice; Gornushkin, Yuri; Gostkin, Mikhail; Gottschalk, Erik; Goudket, Philippe; Gough Eschrich, Ivo; Gournaris, Filimon; Graciani, Ricardo; Graf, Norman; Grah, Christian; Grancagnolo, Francesco; Grandjean, Damien; Grannis, Paul; Grassellino, Anna; Graugés, Eugeni; Gray, Stephen; Green, Michael; Greenhalgh, Justin; Greenshaw, Timothy; Grefe, Christian; Gregor, Ingrid-Maria; Grenier, Gerald; Grimes, Mark; Grimm, Terry; Gris, Philippe; Grivaz, Jean-Francois; Groll, Marius; Gronberg, Jeffrey; Grondin, Denis; Groom, Donald; Gross, Eilam; Grunewald, Martin; Grupen, Claus; Grzelak, Grzegorz; Gu, Jun; Gu, Yun-Ting; Guchait, Monoranjan; Guiducci, Susanna; Guler, Ali Murat; Guler, Hayg; Gulmez, Erhan; Gunion, John; Guo, Zhi Yu; Gurtu, Atul; Ha, Huy Bang; Haas, Tobias; Haase, Andy; Haba, Naoyuki; Haber, Howard; Haensel, Stephan; Hagge, Lars; Hagura, Hiroyuki; Hajdu, Csaba; Haller, Gunther; Haller, Johannes; Hallermann, Lea; Halyo, Valerie; Hamaguchi, Koichi; Hammond, Larry; Han, Liang; Han, Tao; Hand, Louis; Handu, Virender K.; Hano, Hitoshi; Hansen, Christian; Hansen, Jørn Dines; Hansen, Jorgen Beck; Hara, Kazufumi; Harder, Kristian; Hartin, Anthony; Hartung, Walter; Hast, Carsten; Hauptman, John; Hauschild, Michael; Hauviller, Claude; Havranek, Miroslav; Hawkes, Chris; Hawkings, Richard; Hayano, Hitoshi; Hazumi, Masashi; He, An; He, Hong Jian; Hearty, Christopher; Heath, Helen; Hebbeker, Thomas; Hedberg, Vincent; Hedin, David; Heifets, Samuel; Heinemeyer, Sven; Heini, Sebastien; Helebrant, Christian; Helms, Richard; Heltsley, Brian; Henrot-Versille, Sophie; Henschel, Hans; Hensel, Carsten; Hermel, Richard; Herms, Atilà; Herten, Gregor; Hesselbach, Stefan; Heuer, Rolf-Dieter; Heusch, Clemens A.; Hewett, Joanne; Higashi, Norio; Higashi, Takatoshi; Higashi, Yasuo; Higo, Toshiyasu; Hildreth, Michael D.; Hiller, Karlheinz; Hillert, Sonja; Hillier, Stephen James; Himel, Thomas; Himmi, Abdelkader; Hinchliffe, Ian; Hioki, Zenro; Hirano, Koichiro; Hirose, Tachishige; Hisamatsu, Hiromi; Hisano, Junji; Hlaing, Chit Thu; Hock, Kai Meng; Hoeferkamp, Martin; Hohlfeld, Mark; Honda, Yousuke; Hong, Juho; Hong, Tae Min; Honma, Hiroyuki; Horii, Yasuyuki; Horvath, Dezso; Hosoyama, Kenji; Hostachy, Jean-Yves; Hou, Mi; Hou, Wei-Shu; Howell, David; Hronek, Maxine; Hsiung, Yee B.; Hu, Bo; Hu, Tao; Huang, Jung-Yun; Huang, Tong Ming; Huang, Wen Hui; Huedem, Emil; Huggard, Peter; Hugonie, Cyril; Hu-Guo, Christine; Huitu, Katri; Hwang, Youngseok; Idzik, Marek; Ignatenko, Alexandr; Ignatov, Fedor; Ikeda, Hirokazu; Ikematsu, Katsumasa; Ilicheva, Tatiana; Imbault, Didier; Imhof, Andreas; Incagli, Marco; Ingbir, Ronen; Inoue, Hitoshi; Inoue, Youichi; Introzzi, Gianluca; Ioakeimidi, Katerina; Ishihara, Satoshi; Ishikawa, Akimasa; Ishikawa, Tadashi; Issakov, Vladimir; Ito, Kazutoshi; Ivanov, V.V.; Ivanov, Valentin; Ivanyushenkov, Yury; Iwasaki, Masako; Iwashita, Yoshihisa; Jackson, David; Jackson, Frank; Jacobsen, Bob; Jaganathan, Ramaswamy; Jamison, Steven; Janssen, Matthias Enno; Jaramillo-Echeverria, Richard; Jaros, John; Jauffret, Clement; Jawale, Suresh B.; Jeans, Daniel; Jedziniak, Ron; Jeffery, Ben; Jehanno, Didier; Jenner, Leo J.; Jensen, Chris; Jensen, David R.; Jiang, Hairong; Jiang, Xiao Ming; Jimbo, Masato; Jin, Shan; Keith Jobe, R.; Johnson, Anthony; Johnson, Erik; Johnson, Matt; Johnston, Michael; Joireman, Paul; Jokic, Stevan; Jones, James; Jones, Roger M.; Jongewaard, Erik; Jönsson, Leif; Joshi, Gopal; Joshi, Satish C.; Jung, Jin-Young; Junk, Thomas; Juste, Aurelio; Kado, Marumi; Kadyk, John; Käfer, Daniela; Kako, Eiji; Kalavase, Puneeth; Kalinin, Alexander; Kalinowski, Jan; Kamitani, Takuya; Kamiya, Yoshio; Kamiya, Yukihide; Kamoshita, Jun-ichi; Kananov, Sergey; Kanaya, Kazuyuki; Kanazawa, Ken-ichi; Kanemura, Shinya; Kang, Heung-Sik; Kang, Wen; Kanjial, D.; Kapusta, Frédéric; Karataev, Pavel; Karchin, Paul E.; Karlen, Dean; Karyotakis, Yannis; Kashikhin, Vladimir; Kashiwagi, Shigeru; Kasley, Paul; Katagiri, Hiroaki; Kato, Takashi; Kato, Yukihiro; Katzy, Judith; Kaukher, Alexander; Kaur, Manjit; Kawagoe, Kiyotomo; Kawamura, Hiroyuki; Kazakov, Sergei; Kekelidze, V.D.; Keller, Lewis; Kelley, Michael; Kelly, Marc; Kelly, Michael; Kennedy, Kurt; Kephart, Robert; Keung, Justin; Khainovski, Oleg; Khan, Sameen Ahmed; Khare, Prashant; Khovansky, Nikolai; Kiesling, Christian; Kikuchi, Mitsuo; Kilian, Wolfgang; Killenberg, Martin; Kim, Donghee; Kim, Eun San; Kim, Eun-Joo; Kim, Guinyun; Kim, Hongjoo; Kim, Hyoungsuk; Kim, Hyun-Chui; Kim, Jonghoon; Kim, Kwang-Je; Kim, Kyung Sook; Kim, Peter; Kim, Seunghwan; Kim, Shin-Hong; Kim, Sun Kee; Kim, Tae Jeong; Kim, Youngim; Kim, Young-Kee; Kimmitt, Maurice; Kirby, Robert; Kircher, François; Kisielewska, Danuta; Kittel, Olaf; Klanner, Robert; Klebaner, Arkadiy L.; Kleinwort, Claus; Klimkovich, Tatsiana; Klinkby, Esben; Kluth, Stefan; Knecht, Marc; Kneisel, Peter; Ko, In Soo; Ko, Kwok; Kobayashi, Makoto; Kobayashi, Nobuko; Kobel, Michael; Koch, Manuel; Kodys, Peter; Koetz, Uli; Kohrs, Robert; Kojima, Yuuji; Kolanoski, Hermann; Kolodziej, Karol; Kolomensky, Yury G.; Komamiya, Sachio; Kong, Xiang Cheng; Konigsberg, Jacobo; Korbel, Volker; Koscielniak, Shane; Kostromin, Sergey; Kowalewski, Robert; Kraml, Sabine; Krammer, Manfred; Krasnykh, Anatoly; Krautscheid, Thorsten; Krawczyk, Maria; James Krebs, H.; Krempetz, Kurt; Kribs, Graham; Krishnagopal, Srinivas; Kriske, Richard; Kronfeld, Andreas; Kroseberg, Jürgen; Kruchonak, Uladzimir; Kruecker, Dirk; Krüger, Hans; Krumpa, Nicholas A.; Krumshtein, Zinovii; Kuang, Yu Ping; Kubo, Kiyoshi; Kuchler, Vic; Kudoh, Noboru; Kulis, Szymon; Kumada, Masayuki; Kumar, Abhay; Kume, Tatsuya; Kundu, Anirban; Kurevlev, German; Kurihara, Yoshimasa; Kuriki, Masao; Kuroda, Shigeru; Kuroiwa, Hirotoshi; Kurokawa, Shin-ichi; Kusano, Tomonori; Kush, Pradeep K.; Kutschke, Robert; Kuznetsova, Ekaterina; Kvasnicka, Peter; Kwon, Youngjoon; Labarga, Luis; Lacasta, Carlos; Lackey, Sharon; Lackowski, Thomas W.; Lafaye, Remi; Lafferty, George; Lagorio, Eric; Laktineh, Imad; Lal, Shankar; Laloum, Maurice; Lam, Briant; Lancaster, Mark; Lander, Richard; Lange, Wolfgang; Langenfeld, Ulrich; Langeveld, Willem; Larbalestier, David; Larsen, Ray; Lastovicka, Tomas; Lastovicka-Medin, Gordana; Latina, Andrea; Latour, Emmanuel; Laurent, Lisa; Le, Ba Nam; Le, Duc Ninh; Le Diberder, Francois; Dû, Patrick Le; Lebbolo, Hervé; Lebrun, Paul; Lecoq, Jacques; Lee, Sung-Won; Lehner, Frank; Leibfritz, Jerry; Lenkszus, Frank; Lesiak, Tadeusz; Levy, Aharon; Lewandowski, Jim; Leyh, Greg; Li, Cheng; Li, Chong Sheng; Li, Chun Hua; Li, Da Zhang; Li, Gang; Li, Jin; Li, Shao Peng; Li, Wei Ming; Li, Weiguo; Li, Xiao Ping; Li, Xue-Qian; Li, Yuanjing; Li, Yulan; Li, Zenghai; Li, Zhong Quan; Liang, Jian Tao; Liao, Yi; Lilje, Lutz; Guilherme Lima, J.; Lintern, Andrew J.; Lipton, Ronald; List, Benno; List, Jenny; Liu, Chun; Liu, Jian Fei; Liu, Ke Xin; Liu, Li Qiang; Liu, Shao Zhen; Liu, Sheng Guang; Liu, Shubin; Liu, Wanming; Liu, Wei Bin; Liu, Ya Ping; Liu, Yu Dong; Lockyer, Nigel; Logan, Heather E.; Logatchev, Pavel V.; Lohmann, Wolfgang; Lohse, Thomas; Lola, Smaragda; Lopez-Virto, Amparo; Loveridge, Peter; Lozano, Manuel; Lu, Cai-Dian; Lu, Changguo; Lu, Gong-Lu; Lu, Wen Hui; Lubatti, Henry; Lucotte, Arnaud; Lundberg, Björn; Lundin, Tracy; Luo, Mingxing; Luong, Michel; Luth, Vera; Lutz, Benjamin; Lutz, Pierre; Lux, Thorsten; Luzniak, Pawel; Lyapin, Alexey; Lykken, Joseph; Lynch, Clare; Ma, Li; Ma, Lili; Ma, Qiang; Ma, Wen-Gan; Macfarlane, David; Maciel, Arthur; MacLeod, Allan; MacNair, David; Mader, Wolfgang; Magill, Stephen; Magnan, Anne-Marie; Maiheu, Bino; Maity, Manas; Majchrzak, Millicent; Majumder, Gobinda; Makarov, Roman; Makowski, Dariusz; Malaescu, Bogdan; Mallik, C.; Mallik, Usha; Malton, Stephen; Malyshev, Oleg B.; Malysheva, Larisa I.; Mammosser, John; Mamta; Mamuzic, Judita; Manen, Samuel; Manghisoni, Massimo; Manly, Steven; Marcellini, Fabio; Marcisovsky, Michal; Markiewicz, Thomas W.; Marks, Steve; Marone, Andrew; Marti, Felix; Martin, Jean-Pierre; Martin, Victoria; Martin-Chassard, Gisèle; Martinez, Manel; Martinez-Rivero, Celso; Martsch, Dennis; Martyn, Hans-Ulrich; Maruyama, Takashi; Masuzawa, Mika; Mathez, Hervé; Matsuda, Takeshi; Matsumoto, Hiroshi; Matsumoto, Shuji; Matsumoto, Toshihiro; Matsunaga, Hiroyuki; Mättig, Peter; Mattison, Thomas; Mavromanolakis, Georgios; Mawatari, Kentarou; Mazzacane, Anna; McBride, Patricia; McCormick, Douglas; McCormick, Jeremy; McDonald, Kirk T.; McGee, Mike; McIntosh, Peter; McKee, Bobby; McPherson, Robert A.; Meidlinger, Mandi; Meier, Karlheinz; Mele, Barbara; Meller, Bob; Melzer-Pellmann, Isabell-Alissandra; Mendez, Hector; Mercer, Adam; Merkin, Mikhail; Meshkov, I.N.; Messner, Robert; Metcalfe, Jessica; Meyer, Chris; Meyer, Hendrik; Meyer, Joachim; Meyer, Niels; Meyners, Norbert; Michelato, Paolo; Michizono, Shinichiro; Mihalcea, Daniel; Mihara, Satoshi; Mihara, Takanori; Mikami, Yoshinari; Mikhailichenko, Alexander A.; Milardi, Catia; Miller, David J.; Miller, Owen; Miller, Roger J.; Milstene, Caroline; Mimashi, Toshihiro; Minashvili, Irakli; Miquel, Ramon; Mishra, Shekhar; Mitaroff, Winfried; Mitchell, Chad; Miura, Takako; Miyamoto, Akiya; Miyata, Hitoshi; Mjörnmark, Ulf; Mnich, Joachim; Moenig, Klaus; Moffeit, Kenneth; Mokhov, Nikolai; Molloy, Stephen; Monaco, Laura; Monasterio, Paul R.; Montanari, Alessandro; Moon, Sung Ik; Moortgat-Pick, Gudrid A.; Mora de Freitas, Paulo; Morel, Federic; Moretti, Stefano; Morgunov, Vasily; Mori, Toshinori; Morin, Laurent; Morisseau, François; Morita, Yoshiyuki; Morita, Youhei; Morita, Yuichi; Morozov, Nikolai; Morozumi, Yuichi; Morse, William; Moser, Hans-Guenther; Moultaka, Gilbert; Mtingwa, Sekazi; Mudrinic, Mihajlo; Mueller, Alex; Mueller, Wolfgang; Muennich, Astrid; Muhlleitner, Milada Margarete; Mukherjee, Bhaskar; Mukhopadhyaya, Biswarup; Müller, Thomas; Munro, Morrison; Murayama, Hitoshi; Muto, Toshiya; Myneni, Ganapati Rao; Nabhiraj, P.Y.; Nagaitsev, Sergei; Nagamine, Tadashi; Nagano, Ai; Naito, Takashi; Nakai, Hirotaka; Nakajima, Hiromitsu; Nakamura, Isamu; Nakamura, Tomoya; Nakanishi, Tsutomu; Nakao, Katsumi; Nakao, Noriaki; Nakayoshi, Kazuo; Nam, Sang; Namito, Yoshihito; Namkung, Won; Nantista, Chris; Napoly, Olivier; Narain, Meenakshi; Naroska, Beate; Nauenberg, Uriel; Nayyar, Ruchika; Neal, Homer; Nelson, Charles; Nelson, Janice; Nelson, Timothy; Nemecek, Stanislav; Neubauer, Michael; Neuffer, David; Newman, Myriam Q.; Nezhevenko, Oleg; Ng, Cho-Kuen; Nguyen, Anh Ky; Nguyen, Minh; Van Nguyen Thi,Hong; Niebuhr, Carsten; Niehoff, Jim; Niezurawski, Piotr; Nishitani, Tomohiro; Nitoh, Osamu; Noguchi, Shuichi; Nomerotski, Andrei; Noonan, John; Norbeck, Edward; Nosochkov, Yuri; Notz, Dieter; Nowak, Grazyna; Nowak, Hannelies; Noy, Matthew; Nozaki, Mitsuaki; Nyffeler, Andreas; Nygren, David; Oddone, Piermaria; O'Dell, Joseph; Oh, Jong-Seok; Oh, Sun Kun; Ohkuma, Kazumasa; Ohlerich, Martin; Ohmi, Kazuhito; Ohnishi, Yukiyoshi; Ohsawa, Satoshi; Ohuchi, Norihito; Oide, Katsunobu; Okada, Nobuchika; Okada, Yasuhiro; Okamura, Takahiro; Okugi, Toshiyuki; Okumi, Shoji; Okumura, Ken-ichi; Olchevski, Alexander; Oliver, William; Olivier, Bob; Olsen, James; Olsen, Jeff; Olsen, Stephen; Olshevsky, A.G.; Olsson, Jan; Omori, Tsunehiko; Onel, Yasar; Onengut, Gulsen; Ono, Hiroaki; Onoprienko, Dmitry; Oreglia, Mark; Oren, Will; Orimoto, Toyoko J.; Oriunno, Marco; Orlandea, Marius Ciprian; Oroku, Masahiro; Orr, Lynne H.; Orr, Robert S.; Oshea, Val; Oskarsson, Anders; Osland, Per; Ossetski, Dmitri; Österman, Lennart; Ostiguy, Francois; Otono, Hidetoshi; Ottewell, Brian; Ouyang, Qun; Padamsee, Hasan; Padilla, Cristobal; Pagani, Carlo; Palmer, Mark A.; Pam, Wei Min; Pande, Manjiri; Pande, Rajni; Pandit, V.S.; Pandita, P.N.; Pandurovic, Mila; Pankov, Alexander; Panzeri, Nicola; Papandreou, Zisis; Paparella, Rocco; Para, Adam; Park, Hwanbae; Parker, Brett; Parkes, Chris; Parma, Vittorio; Parsa, Zohreh; Parsons, Justin; Partridge, Richard; Pasquinelli, Ralph; Pásztor, Gabriella; Paterson, Ewan; Patrick, Jim; Patteri, Piero; Ritchie Patterson, J.; Pauletta, Giovanni; Paver, Nello; Pavlicek, Vince; Pawlik, Bogdan; Payet, Jacques; Pchalek, Norbert; Pedersen, John; Pei, Guo Xi; Pei, Shi Lun; Pelka, Jerzy; Pellegrini, Giulio; Pellett, David; Peng, G.X.; Penn, Gregory; Penzo, Aldo; Perry, Colin; Peskin, Michael; Peters, Franz; Petersen, Troels Christian; Peterson, Daniel; Peterson, Thomas; Petterson, Maureen; Pfeffer, Howard; Pfund, Phil; Phelps, Alan; Van Phi, Quang; Phillips, Jonathan; Piccolo, Marcello; Piemontese, Livio; Pierini, Paolo; Thomas Piggott, W.; Pike, Gary; Pillet, Nicolas; Jayawardena, Talini Pinto; Piot, Phillippe; Pitts, Kevin; Pivi, Mauro; Plate, Dave; Pleier, Marc-Andre; Poblaguev, Andrei; Poehler, Michael; Poelker, Matthew; Poffenberger, Paul; Pogorelsky, Igor; Poirier, Freddy; Poling, Ronald; Poole, Mike; Popescu, Sorina; Popielarski, John; Pöschl, Roman; Postranecky, Martin; Potukochi, Prakash N.; Prast, Julie; Prat, Serge; Preger, Miro; Prepost, Richard; Price, Michael; Proch, Dieter; Puntambekar, Avinash; Qin, Qing; Qu, Hua Min; Quadt, Arnulf; Quesnel, Jean-Pierre; Radeka, Veljko; Rahmat, Rahmat; Rai, Santosh Kumar; Raimondi, Pantaleo; Ramberg, Erik; Ranjan, Kirti; Rao, Sista V.L.S.; Raspereza, Alexei; Ratti, Alessandro; Ratti, Lodovico; Raubenheimer, Tor; Raux, Ludovic; Ravindran, V.; Raychaudhuri, Sreerup; Re, Valerio; Rease, Bill; Reece, Charles E.; Regler, Meinhard; Rehlich, Kay; Reichel, Ina; Reichold, Armin; Reid, John; Reid, Ron; Reidy, James; Reinhard, Marcel; Renz, Uwe; Repond, Jose; Resta-Lopez, Javier; Reuen, Lars; Ribnik, Jacob; Rice, Tyler; Richard, François; Riemann, Sabine; Riemann, Tord; Riles, Keith; Riley, Daniel; Rimbault, Cécile; Rindani, Saurabh; Rinolfi, Louis; Risigo, Fabio; Riu, Imma; Rizhikov, Dmitri; Rizzo, Thomas; Rochford, James H.; Rodriguez, Ponciano; Roeben, Martin; Rolandi, Gigi; Roodman, Aaron; Rosenberg, Eli; Roser, Robert; Ross, Marc; Rossel, François; Rossmanith, Robert; Roth, Stefan; Rougé, André; Rowe, Allan; Roy, Amit; Roy, Sendhunil B.; Roy, Sourov; Royer, Laurent; Royole-Degieux, Perrine; Royon, Christophe; Ruan, Manqi; Rubin, David; Ruehl, Ingo; Jimeno, Alberto Ruiz; Ruland, Robert; Rusnak, Brian; Ryu, Sun-Young; Sabbi, Gian Luca; Sadeh, Iftach; Sadygov, Ziraddin Y; Saeki, Takayuki; Sagan, David; Sahni, Vinod C.; Saini, Arun; Saito, Kenji; Saito, Kiwamu; Sajot, Gerard; Sakanaka, Shogo; Sakaue, Kazuyuki; Salata, Zen; Salih, Sabah; Salvatore, Fabrizio; Samson, Joergen; Sanami, Toshiya; Levi Sanchez, Allister; Sands, William; Santic, John; Sanuki, Tomoyuki; Sapronov, Andrey; Sarkar, Utpal; Sasao, Noboru; Satoh, Kotaro; Sauli, Fabio; Saunders, Claude; Saveliev, Valeri; Savoy-Navarro, Aurore; Sawyer, Lee; Saxton, Laura; Schäfer, Oliver; Schälicke, Andreas; Schade, Peter; Schaetzel, Sebastien; Scheitrum, Glenn; Schibler, Emilie; Schindler, Rafe; Schlösser, Markus; Schlueter, Ross D.; Schmid, Peter; Schmidt, Ringo Sebastian; Schneekloth, Uwe; Schreiber, Heinz Juergen; Schreiber, Siegfried; Schroeder, Henning; Peter Schüler, K.; Schulte, Daniel; Schultz-Coulon, Hans-Christian; Schumacher, Markus; Schumann, Steffen; Schumm, Bruce A.; Schwienhorst, Reinhard; Schwierz, Rainer; Scott, Duncan J.; Scuri, Fabrizio; Sefkow, Felix; Sefri, Rachid; Seguin-Moreau, Nathalie; Seidel, Sally; Seidman, David; Sekmen, Sezen; Seletskiy, Sergei; Senaha, Eibun; Senanayake, Rohan; Sendai, Hiroshi; Sertore, Daniele; Seryi, Andrei; Settles, Ronald; Sever, Ramazan; Shales, Nicholas; Shao, Ming; Shelkov, G.A.; Shepard, Ken; Shepherd-Themistocleous, Claire; Sheppard, John C.; Shi, Cai Tu; Shidara, Tetsuo; Shim, Yeo-Jeong; Shimizu, Hirotaka; Shimizu, Yasuhiro; Shimizu, Yuuki; Shimogawa, Tetsushi; Shin, Seunghwan; Shioden, Masaomi; Shipsey, Ian; Shirkov, Grigori; Shishido, Toshio; Shivpuri, Ram K.; Shrivastava, Purushottam; Shulga, Sergey; Shumeiko, Nikolai; Shuvalov, Sergey; Si, Zongguo; Siddiqui, Azher Majid; Siegrist, James; Simon, Claire; Simrock, Stefan; Sinev, Nikolai; Singh, Bhartendu K.; Singh, Jasbir; Singh, Pitamber; Singh, R.K.; Singh, S.K.; Singini, Monito; Sinha, Anil K.; Sinha, Nita; Sinha, Rahul; Sinram, Klaus; Sissakian, A.N.; Skachkov, N.B.; Skrinsky, Alexander; Slater, Mark; Slominski, Wojciech; Smiljanic, Ivan; Smith, A J Stewart; Smith, Alex; Smith, Brian J.; Smith, Jeff; Smith, Jonathan; Smith, Steve; Smith, Susan; Smith, Tonee; Neville Snodgrass, W.; Sobloher, Blanka; Sohn, Young-Uk; Solidum, Ruelson; Solyak, Nikolai; Son, Dongchul; Sonmez, Nasuf; Sopczak, Andre; Soskov, V.; Spencer, Cherrill M.; Spentzouris, Panagiotis; Speziali, Valeria; Spira, Michael; Sprehn, Daryl; Sridhar, K.; Srivastava, Asutosh; St. Lorant, Steve; Stahl, Achim; Stanek, Richard P.; Stanitzki, Marcel; Stanley, Jacob; Stefanov, Konstantin; Stein, Werner; Steiner, Herbert; Stenlund, Evert; Stern, Amir; Sternberg, Matt; Stockinger, Dominik; Stockton, Mark; Stoeck, Holger; Strachan, John; Strakhovenko, V.; Strauss, Michael; Striganov, Sergei I.; Strologas, John; Strom, David; Strube, Jan; Stupakov, Gennady; Su, Dong; Sudo, Yuji; Suehara, Taikan; Suehiro, Toru; Suetsugu, Yusuke; Sugahara, Ryuhei; Sugimoto, Yasuhiro; Sugiyama, Akira; Suh, Jun Suhk; Sukovic, Goran; Sun, Hong; Sun, Stephen; Sun, Werner; Sun, Yi; Sun, Yipeng; Suszycki, Leszek; Sutcliffe, Peter; Suthar, Rameshwar L.; Suwada, Tsuyoshi; Suzuki, Atsuto; Suzuki, Chihiro; Suzuki, Shiro; Suzuki, Takashi; Swent, Richard; Swientek, Krzysztof; Swinson, Christina; Syresin, Evgeny; Szleper, Michal; Tadday, Alexander; Takahashi, Rika; Takahashi, Tohru; Takano, Mikio; Takasaki, Fumihiko; Takeda, Seishi; Takenaka, Tateru; Takeshita, Tohru; Takubo, Yosuke; Tanaka, Masami; Tang, Chuan Xiang; Taniguchi, Takashi; Tantawi, Sami; Tapprogge, Stefan; Tartaglia, Michael A.; Tassielli, Giovanni Francesco; Tauchi, Toshiaki; Tavian, Laurent; Tawara, Hiroko; Taylor, Geoffrey; Telnov, Alexandre V.; Telnov, Valery; Tenenbaum, Peter; Teodorescu, Eliza; Terashima, Akio; Terracciano, Giuseppina; Terunuma, Nobuhiro; Teubner, Thomas; Teuscher, Richard; Theilacker, Jay; Thomson, Mark; Tice, Jeff; Tigner, Maury; Timmermans, Jan; Titov, Maxim; Tokareva, N.A.; Tollefson, Kirsten; Tomasek, Lukas; Tomovic, Savo; Tompkins, John; Tonutti, Manfred; Topkar, Anita; Toprek, Dragan; Toral, Fernando; Torrence, Eric; Traversi, Gianluca; Trimpl, Marcel; Mani Tripathi, S.; Trischuk, William; Trodden, Mark; Trubnikov, G.V.; Tschirhart, Robert; Tskhadadze, Edisher; Tsuchiya, Kiyosumi; Tsukamoto, Toshifumi; Tsunemi, Akira; Tucker, Robin; Turchetta, Renato; Tyndel, Mike; Uekusa, Nobuhiro; Ueno, Kenji; Umemori, Kensei; Ummenhofer, Martin; Underwood, David; Uozumi, Satoru; Urakawa, Junji; Urban, Jeremy; Uriot, Didier; Urner, David; Ushakov, Andrei; Usher, Tracy; Uzunyan, Sergey; Vachon, Brigitte; Valerio, Linda; Valin, Isabelle; Valishev, Alex; Vamra, Raghava; Van der Graaf, Harry; Van Kooten, Rick; Van Zandbergen, Gary; Vanel, Jean-Charles; Variola, Alessandro; Varner, Gary; Velasco, Mayda; Velte, Ulrich; Velthuis, Jaap; Vempati, Sundir K.; Venturini, Marco; Vescovi, Christophe; Videau, Henri; Vila, Ivan; Vincent, Pascal; Virey, Jean-Marc; Visentin, Bernard; Viti, Michele; Vo, Thanh Cuong; Vogel, Adrian; Vogt, Harald; von Toerne, Eckhard; Vorozhtsov, S.B.; Vos, Marcel; Votava, Margaret; Vrba, Vaclav; Wackeroth, Doreen; Wagner, Albrecht; Wagner, Carlos E.M.; Wagner, Stephen; Wake, Masayoshi; Walczak, Roman; Walkowiak, Wolfgang; Wallon, Samuel; Walsh, Roberval; Walston, Sean; Waltenberger, Wolfgang; Walz, Dieter; Wang, Chao En; Wang, Chun Hong; Wang, Dou; Wang, Faya; Wang, Guang Wei; Wang, Haitao; Wang, Jiang; Wang, Jiu Qing; Wang, Juwen; Wang, Lanfa; Wang, Lei; Wang, Min-Zu; Wang, Qing; Wang, Shu Hong; Wang, Xiaolian; Wang, Xue-Lei; Wang, Yi Fang; Wang, Zheng; Wanzenberg, Rainer; Ward, Bennie; Ward, David; Warmbein, Barbara; Warner, David W.; Warren, Matthew; Washio, Masakazu; Watanabe, Isamu; Watanabe, Ken; Watanabe, Takashi; Watanabe, Yuichi; Watson, Nigel; Wattimena, Nanda; Wayne, Mitchell; Weber, Marc; Weerts, Harry; Weiglein, Georg; Weiland, Thomas; Weinzierl, Stefan; Weise, Hans; Weisend, John; Wendt, Manfred; Wendt, Oliver; Wenzel, Hans; Wenzel, William A.; Wermes, Norbert; Werthenbach, Ulrich; Wesseln, Steve; Wester, William; White, Andy; White, Glen R.; Wichmann, Katarzyna; Wienemann, Peter; Wierba, Wojciech; Wilksen, Tim; Willis, William; Wilson, Graham W.; Wilson, John A.; Wilson, Robert; Wing, Matthew; Winter, Marc; Wirth, Brian D.; Wolbers, Stephen A.; Wolff, Dan; Wolski, Andrzej; Woodley, Mark D.; Woods, Michael; Woodward, Michael L.; Woolliscroft, Timothy; Worm, Steven; Wormser, Guy; Wright, Dennis; Wright, Douglas; Wu, Andy; Wu, Tao; Wu, Yue Liang; Xella, Stefania; Xia, Guoxing; Xia, Lei; Xiao, Aimin; Xiao, Liling; Xie, Jia Lin; Xing, Zhi-Zhong; Xiong, Lian You; Xu, Gang; Xu, Qing Jing; Yajnik, Urjit A.; Yakimenko, Vitaly; Yamada, Ryuji; Yamaguchi, Hiroshi; Yamamoto, Akira; Yamamoto, Hitoshi; Yamamoto, Masahiro; Yamamoto, Naoto; Yamamoto, Richard; Yamamoto, Yasuchika; Yamanaka, Takashi; Yamaoka, Hiroshi; Yamashita, Satoru; Yamazaki, Hideki; Yan, Wenbiao; Yang, Hai-Jun; Yang, Jin Min; Yang, Jongmann; Yang, Zhenwei; Yano, Yoshiharu; Yazgan, Efe; Yeh, G.P.; Yilmaz, Hakan; Yock, Philip; Yoda, Hakutaro; Yoh, John; Yokoya, Kaoru; Yokoyama, Hirokazu; York, Richard C.; Yoshida, Mitsuhiro; Yoshida, Takuo; Yoshioka, Tamaki; Young, Andrew; Yu, Cheng Hui; Yu, Jaehoon; Yu, Xian Ming; Yuan, Changzheng; Yue, Chong-Xing; Yue, Jun Hui; Zacek, Josef; Zagorodnov, Igor; Zalesak, Jaroslav; Zalikhanov, Boris; Zarnecki, Aleksander Filip; Zawiejski, Leszek; Zeitnitz, Christian; Zeller, Michael; Zerwas, Dirk; Zerwas, Peter; Zeyrek, Mehmet; Zhai, Ji Yuan; Zhang, Bao Cheng; Zhang, Bin; Zhang, Chuang; Zhang, He; Zhang, Jiawen; Zhang, Jing; Zhang, Jing Ru; Zhang, Jinlong; Zhang, Liang; Zhang, X.; Zhang, Yuan; Zhang, Zhige; Zhang, Zhiqing; Zhang, Ziping; Zhao, Haiwen; Zhao, Ji Jiu; Zhao, Jing Xia; Zhao, Ming Hua; Zhao, Sheng Chu; Zhao, Tianchi; Zhao, Tong Xian; Zhao, Zhen Tang; Zhao, Zhengguo; Zhou, De Min; Zhou, Feng; Zhou, Shun; Zhu, Shou Hua; Zhu, Xiong Wei; Zhukov, Valery; Zimmermann, Frank; Ziolkowski, Michael; Zisman, Michael S.; Zomer, Fabian; Zong, Zhang Guo; Zorba, Osman; Zutshi, Vishnu

    2007-01-01

    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.

  7. Multi-Center Traffic Management Advisor Operational Field Test Results

    Science.gov (United States)

    Farley, Todd; Landry, Steven J.; Hoang, Ty; Nickelson, Monicarol; Levin, Kerry M.; Rowe, Dennis W.

    2005-01-01

    The Multi-Center Traffic Management Advisor (McTMA) is a research prototype system which seeks to bring time-based metering into the mainstream of air traffic control (ATC) operations. Time-based metering is an efficient alternative to traditional air traffic management techniques such as distance-based spacing (miles-in-trail spacing) and managed arrival reservoirs (airborne holding). While time-based metering has demonstrated significant benefit in terms of arrival throughput and arrival delay, its use to date has been limited to arrival operations at just nine airports nationally. Wide-scale adoption of time-based metering has been hampered, in part, by the limited scalability of metering automation. In order to realize the full spectrum of efficiency benefits possible with time-based metering, a much more modular, scalable time-based metering capability is required. With its distributed metering architecture, multi-center TMA offers such a capability.

  8. DATA CENTER REMODELING FOR THE INTERNET OF THINGS

    Directory of Open Access Journals (Sweden)

    Cristian IVĂNUŞ

    2015-05-01

    Full Text Available Designing efficient data center is more than ever a challenge for many companies when it comes to meet the requirements of having a greater and extensible computing capacity. It should be stored increasing volumes of data. Applications became increasingly complex. The requirements for running business operations should be very flexible. If we want that ICT infrastructure (Information Technology & Communication to be able to offer, continuosly, high level of services, it is essential to rethink the "robustness" and the need for innovation in data centers. This is true for both servers and storage as well as for the processing power. Companies operating in this field help customers to optimize their data center availability and security by evaluating the energy consumption, cooling capacity and other factors involved in data centers upgrading. The objective is to obtain an optimum in terms of occupied space, most efficient power consumption and most effective cooling in order to achieve a sustainable long term data center operation. The development and modernization explosive data centers as a result to the three major trends existent in the IT (Information Technology now: cloud computing, Internet of Things and Big Data [1, 9].

  9. The Language Research Center's Computerized Test System for environmental enrichment and psychological assessment

    Science.gov (United States)

    Washburn, D. A.; Rumbaugh, D. M.; Richardson, W. K.

    1992-01-01

    In the spring of 1987, we undertook to provide environmental enrichment to nonhuman primate subjects in ways that would complement and even contribute to the bio-behaviorial science that justified the monkeys' captivity. Of course, the psychological well-being of captive primates--and indeed all research species-- has been an area of intense research activity since the 1985 amendment of the Animal Welfare Act. This mandate for researchers to ensure the psychological, as well as physical, fitness of experimental animals catalyzed the humane and scientific interests of the research community. The contemporary literature is replete with proposed means both of assaying and of providing enrichment and well-being. Notwithstanding, consensus on either assessment or intervention has yet to be reached. The paradigm we employed was modelled after successful efforts with chimpanzees. An automated test system was constructed in which subjects responded to computer tasks by manipulating a joystick. The tasks, interactive game-like versions of many of the classic testing paradigms of cognitive and comparative psychology, permitted the controlled presentation of stimuli and demands without the required presence of a human experimenter. Despite significant barriers to the success, rhesus monkeys (Macaca mulatta) and a variety of other primate species (including, of course, humans) have mastered the skills necessary for testing in this paradigm. Previous experiments have illustrated the utility of the test system for addressing questions of learning, memory, attention, perception, and motivation. Additional data have been reported to support the contention that the Language Research Center's Computerized Test System (LRC-CTS) serves its other raison d'etre--providing environmental enrichment and assessing psychological well-being. This paper is designed to augment previous descriptions of the technology and the paradigm for scientists and caretakers interested in environmental

  10. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    Science.gov (United States)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  11. Documentation and archiving of the Space Shuttle wind tunnel test data base. Volume 2: User's Guide to the Archived Data Base

    Science.gov (United States)

    Romere, Paul O.; Brown, Steve Wesley

    1995-01-01

    Development of the Space Shuttle necessitated an extensive wind tunnel test program, with the cooperation of all the major wind tunnels in the United States. The result was approximately 100,000 hours of Space Shuttle wind tunnel testing conducted for aerodynamics, heat transfer, and structural dynamics. The test results were converted into Chrysler DATAMAN computer program format to facilitate use by analysts, a very cost effective method of collecting the wind tunnel test results from many test facilities into one centralized location. This report provides final documentation of the Space Shuttle wind tunnel program. The two-volume set covers the evolution of Space Shuttle aerodynamic configurations and gives wind tunnel test data, titles of wind tunnel data reports, sample data sets, and instructions for accessing the digital data base.

  12. Impact of endobronchial coiling on segmental bronchial lumen in treated and untreated lung lobes: Correlation with changes in lung volume, clinical and pulmonary function tests.

    Science.gov (United States)

    Kloth, C; Thaiss, W M; Hetzel, J; Ditt, H; Grosse, U; Nikolaou, K; Horger, M

    2016-07-01

    To assess the impact of endobronchial coiling on the segment bronchus cross-sectional area and volumes in patients with lung emphysema using quantitative chest-CT measurements. Thirty patients (female = 15; median age = 65.36 years) received chest-CT before and after endobronchial coiling for lung volume reduction (LVR) between January 2010 and December 2014. Thin-slice (0.6 mm) non-enhanced image data sets were acquired both at end-inspiration and end-expiration using helical technique and 120 kV/100-150 mAs. Clinical response was defined as an increase in the walking distance (Six-minute walk test; 6MWT) after LVR-therapy. Additionally, pulmonary function test (PFT) measurements were used for clinical correlation. In the treated segmental bronchia, the cross-sectional lumen area showed significant reduction (p  0.05). In the ipsilateral lobes, the lumina showed no significant changes. In the contralateral lung, we found tendency towards increased cross-sectional area in inspiration (p = 0.06). Volumes of the treated segments correlated with the treated segmental bronchial lumina in expiration (r = 0.80, p volume of the treated lobe in responders only. Endobronchial coiling causes significant decrease in the cross-sectional area of treated segment bronchi in inspiration and a slight increase in expiration accompanied by a volume reduction. • Endobronchial coiling has indirect impact on cross-sectional area of treated segment bronchi • Volume changes of treated lobes correlate with changes in bronchial cross-sectional area • Coil-induced effects reflect their stabilizing and stiffening impact on lung parenchyma • Endobronchial coiling reduces bronchial collapsing compensating the loss of elasticity.

  13. Walt Disney visited Marshall Space Flight Center (MSFC)

    Science.gov (United States)

    1965-01-01

    Walt Disney toured the West Test Area during his visit to the Marshall Space Flight Center on April 13, 1965. The three in center foreground are Karl Heimburg, Director, Test Division; Dr. von Braun, Director, MSFC; and Walt Disney. The Dynamic Test Stand with the S-1C stage being installed is in the background.

  14. Construction of a 2- by 2-foot transonic adaptive-wall test section at the NASA Ames Research Center

    Science.gov (United States)

    Morgan, Daniel G.; Lee, George

    1986-01-01

    The development of a new production-size, two-dimensional, adaptive-wall test section with ventilated walls at the NASA Ames Research Center is described. The new facility incorporates rapid closed-loop operation, computer/sensor integration, and on-line interference assessment and wall corrections. Air flow through the test section is controlled by a series of plenum compartments and three-way slide vales. A fast-scan laser velocimeter was built to measure velocity boundary conditions for the interference assessment scheme. A 15.2-cm- (6.0-in.-) chord NACA 0012 airfoil model will be used in the first experiments during calibration of the facility.

  15. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  16. Market Competition and Density in Liver Transplantation: Relationship to Volume and Outcomes.

    Science.gov (United States)

    Adler, Joel T; Yeh, Heidi; Markmann, James F; Nguyen, Louis L

    2015-08-01

    Liver transplantation centers are unevenly distributed within the Donor Service Areas (DSAs) of the United States. This study assessed how market competition and liver transplantation center density are associated with liver transplantation volume within individual DSAs. We conducted a retrospective cohort study of 53,156 adult liver transplants in 45 DSAs with 110 transplantation centers identified from the Scientific Registry of Transplant Recipients between 2003 and 2012. The following measures were derived annually for each DSA: market competition using the Herfindahl Hirschman Index, transplantation center density by the Average Nearest Neighbor method, liver quality by the Liver Donor Risk Index, and patient risk by the Model for End-Stage Liver Disease. A hierarchical mixed effects negative binomial regression model of the relationship between liver transplants and market factors was created annually. Patient and graft survival were investigated with a Cox proportional hazards model. Transplantation center density was associated with market competition (p market competition (IRR = 1.36; p = 0.02), increased listings (IRR = 1.14; p market variables were associated with increased mortality after transplantation. After controlling for demographic and market factors, a greater concentration of centers was associated with more liver transplants without impacting overall survival. These results warrant additional investigation into the relationship between geospatial factors and liver transplantation volume with consideration for the optimization of scarce resources. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Recovery efficiency test project, Phase 2 activity report. Volume 2, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Overbey, W.K. Jr.; Salamy, S.P.; Locke, C.D.

    1989-02-01

    The Recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency of gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. This volume contains appendices for: (1) supporting material and procedures for ``data frac`` stimulation of zone 6 using nitrogen and nitrogen foam; (2) supporting material and procedures for stimulation no. 1 nitrogen gas frac on zone no. 1; (3) supporting material and procedures for stimulation no. 2 in zone no. 1 using liquid CO{sub 2}; (4) supporting material and procedures for frac no. 3 on zone no.1 using nitrogen foam and proppant; (5) supporting material and procedures for stimulation no. 4 in zones 2--3 and 4 using nitrogen foam and proppant; (6) supporting materials and procedures for stimulation no. 5 in zones 5 and 8; and (7) fracture diagnostics reports and supporting materials.

  18. Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

    Science.gov (United States)

    Wallon, G; Bonnet, A; Guérin, C

    2013-06-01

    Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. We measured delivered V(T) (V(TI)) from four anaesthesia ventilators (Aisys™, Flow-i™, Primus™, and Zeus™) on a pneumatic test lung set with three combinations of lung compliance (C, ml cm H2O(-1)) and resistance (R, cm H2O litre(-1) s(-2)): C60R5, C30R5, C60R20. For each CR, three FGF rates (0.5, 3, 10 litre min(-1)) were investigated at three set V(T)s (300, 500, 800 ml) and two values of PEEP (0 and 10 cm H2O). The volume error = [(V(TI) - V(Tset))/V(Tset)] ×100 was computed in body temperature and pressure-saturated conditions and compared using analysis of variance. For each CR and each set V(T), the absolute value of the volume error significantly declined from Aisys™ to Flow-i™, Zeus™, and Primus™. For C60R5, these values were 12.5% for Aisys™, 5% for Flow-i™ and Zeus™, and 0% for Primus™. With an increase in FGF, absolute values of the volume error increased only for Aisys™ and Zeus™. However, in C30R5, the volume error was minimal at mid-FGF for Aisys™. The results were similar at PEEP 10 cm H2O. Under experimental conditions, the volume error differed significantly between the four new anaesthesia ventilators tested and was influenced by FGF, although this effect may not be clinically relevant.

  19. Measuring the volume of frontal lobe in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Yin Lu; Liu Peifang; Ye Zhaoxiang; Chen Nan; Wang Xing; Li Kuncheng; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of the volume of frontal lobe in Chinese adults of the Han nationality and provide morphological data for the construction of database for Chinese Standard Brain. Methods: This is a clinical multi-center study. Two hundred Chinese healthy volunteers (age range =18 to 70) recruited from 16 hospitals were divided into 5 groups, i.e., age range from 18 to 30, age range from 31 to 40, age range from 41 to 50, age range from 51 to 60, and age range from 61 to 70. Each group contained 20 males and 20 females. All of the volunteers were scanned by MR using T 1 weighted three- dimensional magnetization prepared rapid acquisition gradient echo sequence. We used the manual method to trace the region of interest and measured the left and right frontal lobe volumes separately. All the data were analyzed with SPSS (version 13.0). The sex differences in the frontal lobe volumes were analyzed by independent-samples t test, and the side differences were analyzed by paired-samples t test. Correlation and regression analysis was used between the age and the frontal lobe volumes. Results: In 200 healthy Chinese Han volunteers, the total frontal lobe volumes was (563±73) cm 3 . For male, the volumes of the left and the right frontal lobe were (288±42) cm 3 and (292±41) cm 3 , respectively. The volumes of the left and right frontal lobe in 100 women were (273±30)cm 3 and (274±30) cm 3 respectively. The differences of sex (t=3.334, P 0.05). There were negative correlations between the frontal lobe volumes and age in men and women (r=-0.586, -0.498, P< 0.01). Conclusions: The total frontal lobe volume of men was larger than that of women. The volume of the right frontal lobe was larger than the left frontal lobe in men, and the asymmetries didn't exist in women. The total frontal lobe volumes were both shrinking with age in men and women, which was more rapid in men than in women. (authors)

  20. A Study of Mars Dust Environment Simulation at NASA Johnson Space Center Energy Systems Test Area Resource Conversion Test Facility

    Science.gov (United States)

    Chen, Yuan-Liang Albert

    1999-01-01

    The dust environment on Mars is planned to be simulated in a 20 foot thermal-vacuum chamber at the Johnson Space Center, Energy Systems Test Area Resource Conversion Test Facility in Houston, Texas. This vacuum chamber will be used to perform tests and study the interactions between the dust in Martian air and ISPP hardware. This project is to research, theorize, quantify, and document the Mars dust/wind environment needed for the 20 foot simulation chamber. This simulation work is to support the safety, endurance, and cost reduction of the hardware for the future missions. The Martian dust environment conditions is discussed. Two issues of Martian dust, (1) Dust Contamination related hazards, and (2) Dust Charging caused electrical hazards, are of our interest. The different methods of dust particles measurement are given. The design trade off and feasibility were studied. A glass bell jar system is used to evaluate various concepts for the Mars dust/wind environment simulation. It was observed that the external dust source injection is the best method to introduce the dust into the simulation system. The dust concentration of 30 Mg/M3 should be employed for preparing for the worst possible Martian atmosphere condition in the future. Two approaches thermal-panel shroud for the hardware conditioning are discussed. It is suggested the wind tunnel approach be used to study the dust charging characteristics then to be apply to the close-system cyclone approach. For the operation cost reduction purpose, a dehumidified ambient air could be used to replace the expensive CO2 mixture for some tests.

  1. Hippocampal dose volume histogram predicts Hopkins Verbal Learning Test scores after brain irradiation

    Directory of Open Access Journals (Sweden)

    Catherine Okoukoni, PhD

    2017-10-01

    Full Text Available Purpose: Radiation-induced cognitive decline is relatively common after treatment for primary and metastatic brain tumors; however, identifying dosimetric parameters that are predictive of radiation-induced cognitive decline is difficult due to the heterogeneity of patient characteristics. The memory function is especially susceptible to radiation effects after treatment. The objective of this study is to correlate volumetric radiation doses received by critical neuroanatomic structures to post–radiation therapy (RT memory impairment. Methods and materials: Between 2008 and 2011, 53 patients with primary brain malignancies were treated with conventionally fractionated RT in prospectively accrued clinical trials performed at our institution. Dose-volume histogram analysis was performed for the hippocampus, parahippocampus, amygdala, and fusiform gyrus. Hopkins Verbal Learning Test-Revised scores were obtained at least 6 months after RT. Impairment was defined as an immediate recall score ≤15. For each anatomic region, serial regression was performed to correlate volume receiving a given dose (VD(Gy with memory impairment. Results: Hippocampal V53.4Gy to V60.9Gy significantly predicted post-RT memory impairment (P < .05. Within this range, the hippocampal V55Gy was the most significant predictor (P = .004. Hippocampal V55Gy of 0%, 25%, and 50% was associated with tumor-induced impairment rates of 14.9% (95% confidence interval [CI], 7.2%-28.7%, 45.9% (95% CI, 24.7%-68.6%, and 80.6% (95% CI, 39.2%-96.4%, respectively. Conclusions: The hippocampal V55Gy is a significant predictor for impairment, and a limiting dose below 55 Gy may minimize radiation-induced cognitive impairment.

  2. Reliability and Accuracy of Brain Volume Measurement on MR Imaging

    DEFF Research Database (Denmark)

    Yamagchii, Kechiro; Lassen, Anders; Ring, Poul

    1998-01-01

    Yamaguchi, K., Lassen, A. And Ring, P. Reliability and Accuracy of Brain Volume Measurement on MR Imaging. Abstract at ESMRMB98 European Society for Magnetic Resonance in Medicine and Biology, Geneva, Sept 17-20, 1998 Danish Research Center for Magnetic Resonance, Hvidovre University Hospital...

  3. Histocompatibility Testing for Organ Transplantation Purposes in Albania: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Erkena Shyti

    2014-06-01

    Full Text Available Background: Histocompatibility testing (HT which includes donor-recipient human leukocyte antigen (HLA matching, cross-match testing (XMT and anti-HLA antibody searching are crucial examinations in solid organ transplantation aiming to avoid the hyperacute graft rejection and also to predict the immunological outcome of the graft. Aims: The aim of this study was to analyse the tissue typing data collected at the Laboratory of Immunology and Histocompatibility of the University Hospital Center of Tirana, Albania, in order to define those actions that should be taken for improvements in the situation of kidney transplantation in Albania. Design: Descriptive study. Methods: The donor/recipient cross-match testing was performed through a standard complement-dependent cytotoxicity (CDC assay using separated donor T and B cells that were tested in parallel with the recipient serum sample. All recipient sera were screened for anti-Class I and anti-Class II HLA antibodies using a bead based Luminex anti-HLA antibody screening test. In the case of detected positivity, an allele-specific anti-HLA antibody determination was conducted with the respective Luminex anti-Class I and Class II HLA antibody determination kits. Results: A total of 174 recipients and 202 donors were typed for the purpose of living donor kidney transplantation at our laboratory between January 2006 and December 2012. The mean age and female gender proportion of patients were 34.9 years and 34.5%, respectively, and 48.0 years and 65.3% for the donors, respectively. Here, 25.9% of the patients reported a positive complement-dependent cytotoxicity cross-match test and/or a positive anti-HLA antibody testing result. Eighteen patients that were negative for the complement-dependent cytotoxicity cross-match test were positive for anti-HLA antibodies. Conclusion: The predominant causes of end-stage renal disease (ESRD in our patient population are chronic pyelonephritis and

  4. European Registry of Carotid Artery Stenting: results from a prospective registry of eight high volume EUROPEAN institutions.

    Science.gov (United States)

    Stabile, Eugenio; Garg, Pallav; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitry; Werner, Martin; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Mauri, Laura; Rubino, Paolo

    2012-08-01

    Carotid endarterectomy (CEA) is the standard revascularization therapy to prevent stroke in patients with carotid artery disease. Carotid artery stenting (CAS) could be considered a potential alternative in patients at high surgical risk. Recent clinical trials have challenged this concept due a relatively high incidence of post-CAS adverse events, which occurred in low volume centers. The aim of this study was to evaluate the outcomes associated with neuroprotected CAS in selected high volume centers. From January 2007 to December 2007, 1,611 patients underwent neuroprotected CAS in eight European Centers. For each patients, clinical, procedural, and one month follow-up data from all patients have been collected. An independent clinical events committee adjudicated the events. Overall in hospital death was 0.06% (one patient), whereas in-hospital stroke was 0.49% (eight patients). Between hospital discharge and 30 days three additional patients died (0.18%) and 10 patients experienced a stroke (0.67%). Overall 30 days mortality was 0.24% (four patients) and stroke incidence 1.12% (18 patients). The 30 day stroke/death rate was 1.36%. CAS is a reasonable alternative to CEA to treat carotid artery atherosclerosis in well-experienced high volume centers. These data suggest that future prospective trials comparing CAS and CEA outcomes should include only centers highly experienced in both treatment modalities. Copyright © 2012 Wiley Periodicals, Inc.

  5. Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique – feasibility study

    International Nuclear Information System (INIS)

    Baxa, Jan; Vendiš, Tomáš; Moláček, Jiří; Štěpánková, Lucie; Flohr, Thomas; Schmidt, Bernhard; Korporaal, Johannes G.; Ferda, Jiří

    2014-01-01

    Purpose: To verify the technical feasibility of low contrast volume (40 mL) run-off CT angiography (run-off CTA) with the individual scan time optimization based on double-level test bolus technique. Materials and methods: A prospective study of 92 consecutive patients who underwent run-off CTA performed with 40 mL of contrast medium (injection rate of 6 mL/s) and optimized scan times on a second generation of dual-source CT. Individual optimized scan times were calculated from aortopopliteal transit times obtained on the basis of double-level test bolus technique – the single injection of 10 mL test bolus and dynamic acquisitions in two levels (abdominal aorta and popliteal arteries). Intraluminal attenuation (HU) was measured in 6 levels (aorta, iliac, femoral and popliteal arteries, middle and distal lower-legs) and subjective quality (3-point score) was assessed. Relations of image quality, test bolus parameters and arterial circulation involvement were analyzed. Results: High mean attenuation (HU) values (468; 437; 442; 440; 342; 274) and quality score in all monitored levels was achieved. In 91 patients (0.99) the sufficient diagnostic quality (score 1–2) in aorta, iliac and femoral arteries was determined. A total of 6 patients (0.07) were not evaluable in distal lower-legs. Only the weak indirect correlation of image quality and test-bolus parameters was proved in iliac, femoral and popliteal levels (r values: −0.263, −0.298 and −0.254). The statistically significant difference of the test-bolus parameters and image quality was proved in patients with occlusive and aneurysmal disease. Conclusion: We proved the technical feasibility and sufficient quality of run-off CTA with low volume of contrast medium and optimized scan time according to aortopopliteal transit time calculated from double-level test bolus

  6. Testing General Relativity with Stellar Orbits around the Supermassive Black Hole in Our Galactic Center.

    Science.gov (United States)

    Hees, A; Do, T; Ghez, A M; Martinez, G D; Naoz, S; Becklin, E E; Boehle, A; Chappell, S; Chu, D; Dehghanfar, A; Kosmo, K; Lu, J R; Matthews, K; Morris, M R; Sakai, S; Schödel, R; Witzel, G

    2017-05-26

    We demonstrate that short-period stars orbiting around the supermassive black hole in our Galactic center can successfully be used to probe the gravitational theory in a strong regime. We use 19 years of observations of the two best measured short-period stars orbiting our Galactic center to constrain a hypothetical fifth force that arises in various scenarios motivated by the development of a unification theory or in some models of dark matter and dark energy. No deviation from general relativity is reported and the fifth force strength is restricted to an upper 95% confidence limit of |α|<0.016 at a length scale of λ=150 astronomical units. We also derive a 95% confidence upper limit on a linear drift of the argument of periastron of the short-period star S0-2 of |ω[over ˙]_{S0-2}|<1.6×10^{-3}  rad/yr, which can be used to constrain various gravitational and astrophysical theories. This analysis provides the first fully self-consistent test of the gravitational theory using orbital dynamic in a strong gravitational regime, that of a supermassive black hole. A sensitivity analysis for future measurements is also presented.

  7. Transportation management center data capture for performance and mobility measures reference manual.

    Science.gov (United States)

    2013-03-01

    The Guide to Transportation Management Center (TMC) Data Capture for Performance and Mobility Measures is a two-volume document consisting of a summary Guidebook and this Reference Manual. These documents provide technical guidance and recommended pr...

  8. PENERAPAN PENDEKATAN KONTEKSTUAL TERHADAP PENGUASAAN KONSEP DASAR MATERI VOLUME BENDA PUTAR

    Directory of Open Access Journals (Sweden)

    Alpha Galih Adirakasiwi

    2018-02-01

    Full Text Available ABSTRACTThe purpose of this study was determine the application of contextual teaching learning approach to improve the mastery of concepts volume of the rotary object. The study design was nonequivalent pretest-posttest control group design. Data collection technique used pretest and posttest to determine the mastery of concepts of volume of the rotary object. Hypothesis testing using t-test to compare the the mastery of concepts volume of the rotary object in the experimental class and control class, then a further test by comparing the mean (compare means and average absolute gain Based on the research result the data show that it can be concluded that the approach of contextual learning significantly distinction of concepts volume of the rotary object. Keywords:  Contextual Teaching Learning Approach, The Mastery of Concepts, Volume of The Rotary Object

  9. Finite-volume scheme for anisotropic diffusion

    Energy Technology Data Exchange (ETDEWEB)

    Es, Bram van, E-mail: bramiozo@gmail.com [Centrum Wiskunde & Informatica, P.O. Box 94079, 1090GB Amsterdam (Netherlands); FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, The Netherlands" 1 (Netherlands); Koren, Barry [Eindhoven University of Technology (Netherlands); Blank, Hugo J. de [FOM Institute DIFFER, Dutch Institute for Fundamental Energy Research, The Netherlands" 1 (Netherlands)

    2016-02-01

    In this paper, we apply a special finite-volume scheme, limited to smooth temperature distributions and Cartesian grids, to test the importance of connectivity of the finite volumes. The area of application is nuclear fusion plasma with field line aligned temperature gradients and extreme anisotropy. We apply the scheme to the anisotropic heat-conduction equation, and compare its results with those of existing finite-volume schemes for anisotropic diffusion. Also, we introduce a general model adaptation of the steady diffusion equation for extremely anisotropic diffusion problems with closed field lines.

  10. Cavitation erosion in sodium flow, sodium cavitation tunnel testing

    International Nuclear Information System (INIS)

    Courbiere, Pierre.

    1981-04-01

    The high-volume sodium flows present in fast neutron reactors are liable to induce cavitation phenomena in various portion of the sodium lines and pumps. The absence of sufficient data in this area led the C.E.A. to undertake an erosion research program in cavitating sodium flow. This paper discusses the considerations leading to the definition and execution of sodium cavitation erosion tests, and reviews the tests run with 400 0 C sodium on various steel grades: 316, 316 L, 316 Ti (Z8CNDT17-12), Poral (Z3CND18-12), 304 L and LN2 - clad 316 L (Ni coating-clad 316 L). Acoustic detection and signal processing methods were used with an instrument package designed and implemented at the Cadarache Nuclear Research Center

  11. The effect of acetazolamide on cerebral blood volume and intracranial pressure in patients with hydrocephalus. Theoretical background of the acetazolamide challenge test

    International Nuclear Information System (INIS)

    Ogawa, Daiji

    2000-01-01

    The acetazolamide challenge test is one of the useful tests for diagnosing normal pressure hydrocephalus (NPH). It has the advantage of being less invasive than other tests. However, the manner of increment in cerebral blood volume (CBV) has not been well clarified. Therefore, the theoretical background of the test is also unclear. The aims of this study were to evaluate the effect of acetazolamide on CBV and intracranial pressure (ICP) and elucidate the theoretical background of the test. Thirteen patients with NPH were studied. CBV and ICP were measured before and after the intravenous injection of acetazolamide (1000 mg). CBV was evaluated by means of cerebral pool SPECT; ICP was evaluated by OSAKA telesensor or a pressure transducer via ventricular catheter. Immediately after the injection, CBV increased rapidly, reaching its maximum (15% increase) at 6 minutes. Then CBV gradually decreased. ICP also elevated rapidly, reaching its maximum (12.6 mmHg elevation) at 4 minutes. A gradual decrement ICP was observed, and 26 minutes after injection, the ICP became lower than the pre-injection level. The rapid increase in CBV caused the ICP elevation, and the increment ratio reflected the cerebral compliance. Therefore, we concluded that the acetazolamide challenge test is based on the alteration of cerebral compliance seen in NPH patients. The decrement ratio of ICP is affected not only by the resistance cerebrospinal fluid (CSF) absorption but also by decrease in the CBV and CSF production induced by acetazolamide. Consequently, it is difficult to evaluate the resistance of CSF absorption by this test. Because CBV increased in all cases, it is assumed that acetazolamide administration can be used to reliably load the volume. (author)

  12. A comparison of volume control and pressure-regulated volume control ventilation in acute respiratory failure

    OpenAIRE

    Guldager, Henrik; Nielsen, Soeren L; Carl, Peder; Soerensen, Mogens B

    1997-01-01

    Background: The aim of this study was to test the hypothesis that a new mode of ventilation (pressure-regulated volume control; PRVC) is associated with improvements in respiratory mechanics and outcome when compared with conventional volume control (VC) ventilation in patients with acute respiratory failure. We conducted a randomised, prospective, open, cross over trial on 44 patients with acute respiratory failure in the general intensive care unit of a university hospital. After a stabiliz...

  13. Demonstration, testing, ampersand evaluation of in situ heating of soil. Draft final report, Volume II: Appendices A to E

    International Nuclear Information System (INIS)

    Dev, H.; Enk, J.; Jones, D.; Saboto, W.

    1996-01-01

    This document is a draft final report for US DOE contract entitled, open-quotes Demonstration Testing and Evaluation of In Situ Soil Heating,close quotes Contract No. DE-AC05-93OR22160, IITRI Project No. C06787. This report is presented in two volumes. Volume I contains the technical report This document is Volume II, containing appendices with background information and data. In this project approximately 300 cu. yd. of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. When scaled up, this process can be used for the environmental clean up and restoration of DOE sites contaminated with VOCs and other organic chemicals boiling up to 120 degrees to 130 degrees C in the vadose zone. Although it may applied to many types of soil formations, it is particularly attractive for low permeability clayey soil where conventional in situ venting techniques are limited by low air flow

  14. Environmental Report 1995. Volume 1

    International Nuclear Information System (INIS)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M.

    1996-09-01

    This report contains the results of Lawrence Livermore National Laboratory's (LLNL) environmental monitoring and compliance effort and an assessment of the impact of LLNL operations on the environment and the public. This first volume describes LLNL's environmental impact and compliance activities and features descriptive and explanatory text, summary data tables, and plots showing data trends. The summary data include measures of the center of data, their spread or variability, and their extreme values. Chapters on monitoring air, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation are present

  15. Environmental Report 1995. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Harrach, R.J.; Failor, R.A.; Gallegos, G.M. [and others

    1996-09-01

    This report contains the results of Lawrence Livermore National Laboratory`s (LLNL) environmental monitoring and compliance effort and an assessment of the impact of LLNL operations on the environment and the public. This first volume describes LLNL`s environmental impact and compliance activities and features descriptive and explanatory text, summary data tables, and plots showing data trends. The summary data include measures of the center of data, their spread or variability, and their extreme values. Chapters on monitoring air, sewage, surface water, ground water, soil and sediment, vegetation and foodstuff, and environmental radiation are present.

  16. Artificial Intelligence Can Predict Daily Trauma Volume and Average Acuity.

    Science.gov (United States)

    Stonko, David P; Dennis, Bradley M; Betzold, Richard D; Peetz, Allan B; Gunter, Oliver L; Guillamondegui, Oscar D

    2018-04-19

    The goal of this study was to integrate temporal and weather data in order to create an artificial neural network (ANN) to predict trauma volume, the number of emergent operative cases, and average daily acuity at a level 1 trauma center. Trauma admission data from TRACS and weather data from the National Oceanic and Atmospheric Administration (NOAA) was collected for all adult trauma patients from July 2013-June 2016. The ANN was constructed using temporal (time, day of week), and weather factors (daily high, active precipitation) to predict four points of daily trauma activity: number of traumas, number of penetrating traumas, average ISS, and number of immediate OR cases per day. We trained a two-layer feed-forward network with 10 sigmoid hidden neurons via the Levenberg-Marquardt backpropagation algorithm, and performed k-fold cross validation and accuracy calculations on 100 randomly generated partitions. 10,612 patients over 1,096 days were identified. The ANN accurately predicted the daily trauma distribution in terms of number of traumas, number of penetrating traumas, number of OR cases, and average daily ISS (combined training correlation coefficient r = 0.9018+/-0.002; validation r = 0.8899+/- 0.005; testing r = 0.8940+/-0.006). We were able to successfully predict trauma and emergent operative volume, and acuity using an ANN by integrating local weather and trauma admission data from a level 1 center. As an example, for June 30, 2016, it predicted 9.93 traumas (actual: 10), and a mean ISS score of 15.99 (actual: 13.12); see figure 3. This may prove useful for predicting trauma needs across the system and hospital administration when allocating limited resources. Level III STUDY TYPE: Prognostic/Epidemiological.

  17. 76 FR 57744 - Advisory Committee to the Director (ACD), Centers for Disease Control and Prevention (CDC)-Ethics...

    Science.gov (United States)

    2011-09-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Advisory Committee to the Director (ACD), Centers for Disease Control and Prevention (CDC)--Ethics Subcommittee (ES) Correction: This notice was published in the Federal Register on September 8, 2011, Volume 76, Number 174...

  18. User-centered development and testing of a monitoring system that provides feedback regarding physical functioning to elderly people

    Directory of Open Access Journals (Sweden)

    Vermeulen J

    2013-08-01

    Full Text Available Joan Vermeulen,1 Jacques CL Neyens,1 Marieke D Spreeuwenberg,1 Erik van Rossum,1,2 Walther Sipers,3 Herbert Habets,3 David J Hewson,4 Luc P de Witte1,2 1School for Public Health and Primary Care (CAPHRI, Maastricht University, Maastricht, The Netherlands; 2Research Center for Technology in Care, Zuyd University of Applied Sciences, Heerlen, The Netherlands; 3Expertise Center for Elderly Care, Orbis Medical Center, Sittard, The Netherlands; 4Institute Charles Delaunay, Université de Technologie de Troyes, Troyes, France Purpose: To involve elderly people during the development of a mobile interface of a monitoring system that provides feedback to them regarding changes in physical functioning and to test the system in a pilot study. Methods and participants: The iterative user-centered development process consisted of the following phases: (1 selection of user representatives; (2 analysis of users and their context; (3 identification of user requirements; (4 development of the interface; and (5 evaluation of the interface in the lab. Subsequently, the monitoring and feedback system was tested in a pilot study by five patients who were recruited via a geriatric outpatient clinic. Participants used a bathroom scale to monitor weight and balance, and a mobile phone to monitor physical activity on a daily basis for six weeks. Personalized feedback was provided via the interface of the mobile phone. Usability was evaluated on a scale from 1 to 7 using a modified version of the Post-Study System Usability Questionnaire (PSSUQ; higher scores indicated better usability. Interviews were conducted to gain insight into the experiences of the participants with the system. Results: The developed interface uses colors, emoticons, and written and/or spoken text messages to provide daily feedback regarding (changes in weight, balance, and physical activity. The participants rated the usability of the monitoring and feedback system with a mean score of 5

  19. Eddy current manual, volume 2

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1984-09-01

    This report on eddy current testing is divided into three sections: (a) Demonstration of Basic Principles, (b) Practical (Laboratory) Tests and, (c) Typical Certification Questions. It is intended to be used as a supplement to ΣEddy Current Manual, Volume 1Σ (AECL-7523) during CSNDT Foundation Level II and III courses

  20. ORNL's Controlled Fusion Atomic Data Center

    International Nuclear Information System (INIS)

    Barnett, C.F.; Gregory, D.C.

    1983-01-01

    The Data Center maintains a detailed bibliography of atomic data measurements and calculations for processes of interest to the fusion community. One hundred nineteen journals are regularly searched for papers of interest, including back issues to 1950. Entries are categorized by author, process, reactants, energy range, and theory/experiment. Complete bibliographies have been published since 1978 and a computerized data retrieval system is available. In addition, an updated and extended multi-volume critical compilation of cross sections (the ORNL Redbooks) is under way

  1. A spatial discretization of the MHD equations based on the finite volume - spectral method

    International Nuclear Information System (INIS)

    Miyoshi, Takahiro

    2000-05-01

    Based on the finite volume - spectral method, we present new discretization formulae for the spatial differential operators in the full system of the compressible MHD equations. In this approach, the cell-centered finite volume method is adopted in a bounded plane (poloidal plane), while the spectral method is applied to the differential with respect to the periodic direction perpendicular to the poloidal plane (toroidal direction). Here, an unstructured grid system composed of the arbitrary triangular elements is utilized for constructing the cell-centered finite volume method. In order to maintain the divergence free constraint of the magnetic field numerically, only the poloidal component of the rotation is defined at three edges of the triangular element. This poloidal component is evaluated under the assumption that the toroidal component of the operated vector times the radius, RA φ , is linearly distributed in the element. The present method will be applied to the nonlinear MHD dynamics in an realistic torus geometry without the numerical singularities. (author)

  2. Proceedings of RIKEN BNL Research Center Workshop, RHIC Spin Physics V, Volume 32, February 21, 2001

    International Nuclear Information System (INIS)

    BUNCE, G.; SAITO, N.; VIGDOR, S.; ROSER, T.; SPINKA, H.; ENYO, H.; BLAND, L.C.; GURYN, W.

    2001-01-01

    The RIKEN BNL Research Center (RBRC) was established in April 1997 at Brookhaven National Laboratory. It is funded by the ''Rikagaku Kenkysho'' (RIKEN, The Institute of Physical and Chemical Research) of Japan. The Center is dedicated to the study of strong interactions, including spin physics, lattice QCD and RHIC physics through the nurturing of a new generation of young physicists. During the fast year, the Center had only a Theory Group. In the second year, an Experimental Group was also established at the Center. At present, there are seven Fellows and nine post dots in these two groups. During the third year, we started a new Tenure Track Strong Interaction Theory RHIC Physics Fellow Program, with six positions in the academic year 1999-2000; this program will increase to include eleven theorists in the next academic year, and, in the year after, also be extended to experimental physics. In addition, the Center has an active workshop program on strong interaction physics, about ten workshops a year, with each workshop focused on a specific physics problem. Each workshop speaker is encouraged to select few of the most important transparencies from his or her presentation, accompanied by a page of explanation. This material is collected at the end of the workshop by the organizer to form proceedings, which can therefore be available within a short time. The construction of a 0.6 teraflop parallel processor, which was begun at the Center on February 19, 1998, was completed on August 28, 1998

  3. NASA University Research Centers Technical Advances in Education, Aeronautics, Space, Autonomy, Earth and Environment

    Science.gov (United States)

    Jamshidi, M. (Editor); Lumia, R. (Editor); Tunstel, E., Jr. (Editor); White, B. (Editor); Malone, J. (Editor); Sakimoto, P. (Editor)

    1997-01-01

    This first volume of the Autonomous Control Engineering (ACE) Center Press Series on NASA University Research Center's (URC's) Advanced Technologies on Space Exploration and National Service constitute a report on the research papers and presentations delivered by NASA Installations and industry and Report of the NASA's fourteen URC's held at the First National Conference in Albuquerque, New Mexico from February 16-19, 1997.

  4. Trading volume and the number of trades

    OpenAIRE

    Marwan Izzeldin

    2007-01-01

    Trading volume and the number of trades are both used as proxies for market activity, with disagreement as to which is the better proxy for market activity. This paper investigates this issue using high frequency data for Cisco and Intel in 1997. A number of econometric methods are used, including GARCH augmented with lagged trading volume and number of trades, tests based on moment restrictions, regression analysis of volatility on volume and trades, normality of returns when standardized by...

  5. Oak Ridge rf Test Facility

    International Nuclear Information System (INIS)

    Gardner, W.L.; Hoffman, D.J.; McCurdy, H.C.; McManamy, T.J.; Moeller, J.A.; Ryan, P.M.

    1985-01-01

    The rf Test Facility (RFTF) of Oak Ridge National Laboratory (ORNL) provides a national facility for the testing and evaluation of steady-state, high-power (approx.1.0-MW) ion cyclotron resonance heating (ICRH) systems and components. The facility consists of a vacuum vessel and two fully tested superconducting development magnets from the ELMO Bumpy Torus Proof-of-Principle (EBT-P) program. These are arranged as a simple mirror with a mirror ratio of 4.8. The axial centerline distance between magnet throat centers is 112 cm. The vacuum vessel cavity has a large port (74 by 163 cm) and a test volume adequate for testing prototypic launchers for Doublet III-D (DIII-D), Tore Supra, and the Tokamak Fusion Test Reactor (TFTR). Attached to the internal vessel walls are water-cooled panels for removing the injected rf power. The magnets are capable of generating a steady-state field of approx.3 T on axis in the magnet throats. Steady-state plasmas are generated in the facility by cyclotron resonance breakdown using a dedicated 200-kW, 28-GHz gyrotron. Available rf sources cover a frequency range of 2 to 200 MHz at 1.5 kW and 3 to 18 MHz at 200 kW, with several sources at intermediate parameters. Available in July 1986 will be a >1.0-MW, cw source spanning 40 to 80 MHz. 5 figs

  6. [Relationship between unipedal stance test score and center of pressure velocity in elderly].

    Science.gov (United States)

    Rodrigo Antonio, Guzmán; Rony, Silvestre; Francisco Aniceto, Rodríguez; David Andrés, Arriagada; Pablo Andrés, Ortega

    2011-01-01

    Frequent falls are one of the most important health problems in the elderly population. The unipedal stance test (UPST), asses postural stability and is used in fall risk measures. Despite this, there is little information about its relationship with posturographic parameters (PP) that characterizes postural stability. Center of pressure velocity (CoPV) is one of the best PP that describes postural stability. The aim of this study was to analyze the relation between UST score and CoPV in elderly population. A sample of 38 healthy elderly subjects where divided in two groups according to their UPST score, low performance (LP, n=11) and high performance (HP, n=27). The correlation between UPST score and COP mean velocity (CoPmV), recorded from a posturographic test, was analyzed between both groups. An inverse correlation between UPST score and CoPmV was found in both groups. However, this was higher in the LP group (r=-0.69, P=.02) compared to the HP (r=-0.39, P=.04). Based on the results of this investigation, it may be concluded that the achievement on UPST has an inverse relationship with CoPmV, especially in subjects with low performance in the UPST. Copyright © 2010 SEGG. Published by Elsevier Espana. All rights reserved.

  7. Taper and volume equations for selected Appalachian hardwood species

    Science.gov (United States)

    A. Jeff Martin

    1981-01-01

    Coefficients for five taper/volume models are developed for 18 Appalachian hardwood species. Each model can be used to estimate diameter at any point on the bole, height to any preselected diameter, and cubic-foot volume between any two points on the bole. The resulting equations were tested on six sets of independent data and an evaluation of these tests is included,...

  8. An Eulerian finite volume solver for multi-material fluid flows with cylindrical symmetry

    International Nuclear Information System (INIS)

    Bernard-Champmartin, Aude; Ghidaglia, Jean-Michel; Braeunig, Jean-Philippe

    2013-01-01

    In this paper, we adapt a pre-existing 2D cartesian cell centered finite volume solver to treat the compressible 3D Euler equations with cylindrical symmetry. We then extend it to multi-material flows. Assuming cylindrical symmetry with respect to the z axis (i.e. all the functions do not depend explicitly on the angular variable h), we obtain a set of five conservation laws with source terms that can be decoupled in two systems solved on a 2D orthogonal mesh in which a cell as a torus geometry. A specific up-winding treatment of the source term is required and implemented for the stationary case. Test cases will be presented for vanishing and non-vanishing azimuthal velocity uh. (authors)

  9. Modernization of NASA's Johnson Space Center Chamber: A Payload Transport Rail System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

    Science.gov (United States)

    Garcia, Sam; Homan, Jonathan; Speed, John

    2016-01-01

    NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the "Great Observatories", scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describe the challenges of developing, integrating and modifying new payload rails capable of transporting payloads within the thermal vacuum chamber up to 65,000 pounds. Ambient and Cryogenic Operations required to configure for testing will be explained. Lastly review historical payload configurations stretching from the Apollo program era to current James Webb Space Telescope testing.

  10. Second generation pressurized fluidized-bed combustion (PFBC) research and development, Phase 2 --- Task 4, carbonizer testing. Volume 2, Data reconciliation

    Energy Technology Data Exchange (ETDEWEB)

    Froehlich, R.; Robertson, A.; Vanhook, J.; Goyal, A.; Rehmat, A.; Newby, R.

    1994-11-01

    During the period beginning November 1991 and ending September 1992, a series of tests were conducted at Foster Wheeler Development Corporation in a fluidized-bed coal carbonizer to determine its performance characteristics. The carbonizer was operated for 533 hours in a jetting fluidized-bed configuration during which 36 set points (steady-state periods) were achieved. Extensive data were collected on the feed and product stream compositions, heating values, temperatures, and flow rates. With these data, elemental and energy balances were computed to evaluate and confirm accuracy of the data. The carbonizer data were not as self-consistent as could be desired (balance closure imperfection). A software package developed by Science Ventures, Inc., of California, called BALAID, was used to reconcile the carbonizer data; the details of the reconciliation have been given in Volume 1 of this report. The reconciled data for the carbonizer were rigorously analyzed, correlations were developed, and the model was updated accordingly. The model was then used in simulating each of the 36 steady-state periods achieved in the pilot plant. The details are given in this Volume one. This Volume 2 provides details of the carbonizer data reconciliation.

  11. A nominally second-order cell-centered Lagrangian scheme for simulating elastic-plastic flows on two-dimensional unstructured grids

    Science.gov (United States)

    Maire, Pierre-Henri; Abgrall, Rémi; Breil, Jérôme; Loubère, Raphaël; Rebourcet, Bernard

    2013-02-01

    In this paper, we describe a cell-centered Lagrangian scheme devoted to the numerical simulation of solid dynamics on two-dimensional unstructured grids in planar geometry. This numerical method, utilizes the classical elastic-perfectly plastic material model initially proposed by Wilkins [M.L. Wilkins, Calculation of elastic-plastic flow, Meth. Comput. Phys. (1964)]. In this model, the Cauchy stress tensor is decomposed into the sum of its deviatoric part and the thermodynamic pressure which is defined by means of an equation of state. Regarding the deviatoric stress, its time evolution is governed by a classical constitutive law for isotropic material. The plasticity model employs the von Mises yield criterion and is implemented by means of the radial return algorithm. The numerical scheme relies on a finite volume cell-centered method wherein numerical fluxes are expressed in terms of sub-cell force. The generic form of the sub-cell force is obtained by requiring the scheme to satisfy a semi-discrete dissipation inequality. Sub-cell force and nodal velocity to move the grid are computed consistently with cell volume variation by means of a node-centered solver, which results from total energy conservation. The nominally second-order extension is achieved by developing a two-dimensional extension in the Lagrangian framework of the Generalized Riemann Problem methodology, introduced by Ben-Artzi and Falcovitz [M. Ben-Artzi, J. Falcovitz, Generalized Riemann Problems in Computational Fluid Dynamics, Cambridge Monogr. Appl. Comput. Math. (2003)]. Finally, the robustness and the accuracy of the numerical scheme are assessed through the computation of several test cases.

  12. Lung volumes: measurement, clinical use, and coding.

    Science.gov (United States)

    Flesch, Judd D; Dine, C Jessica

    2012-08-01

    Measurement of lung volumes is an integral part of complete pulmonary function testing. Some lung volumes can be measured during spirometry; however, measurement of the residual volume (RV), functional residual capacity (FRC), and total lung capacity (TLC) requires special techniques. FRC is typically measured by one of three methods. Body plethysmography uses Boyle's Law to determine lung volumes, whereas inert gas dilution and nitrogen washout use dilution properties of gases. After determination of FRC, expiratory reserve volume and inspiratory vital capacity are measured, which allows the calculation of the RV and TLC. Lung volumes are commonly used for the diagnosis of restriction. In obstructive lung disease, they are used to assess for hyperinflation. Changes in lung volumes can also be seen in a number of other clinical conditions. Reimbursement for measurement of lung volumes requires knowledge of current procedural terminology (CPT) codes, relevant indications, and an appropriate level of physician supervision. Because of recent efforts to eliminate payment inefficiencies, the 10 previous CPT codes for lung volumes, airway resistance, and diffusing capacity have been bundled into four new CPT codes.

  13. Summary of Stirling Convertor Testing at NASA Glenn Research Center in Support of Stirling Radioisotope Power System Development

    Science.gov (United States)

    Schifer, Nicholas A.; Oriti, Salvatore M.

    2013-01-01

    The NASA Glenn Research Center (GRC) has been testing 100 We class, free-piston Stirling convertors for potential use in Stirling Radioisotope Power Systems (RPS) for space science and exploration missions. Free-piston Stirling convertors are capable of achieving a 38% conversion efficiency, making Stirling attractive for meeting future power system needs in light of the shrinking U.S. plutonium fuel supply. Convertors currently on test include four Stirling Technology Demonstration Convertors (TDCs), manufactured by the Stirling Technology Company (STC), and six Advanced Stirling Convertors (ASCs), manufactured by Sunpower, Inc. Total hours of operation is greater than 514,000 hours (59 years). Several tests have been initiated to demonstrate the functionality of Stirling convertors for space applications, including: in-air extended operation, thermal vacuum extended operation. Other tests have also been conducted to characterize Stirling performance in anticipated mission scenarios. Data collected during testing has been used to support life and reliability estimates, drive design changes and improve quality, and plan for expected mission scenarios. This paper will provide a summary of convertors tested at NASA GRC and discuss lessons learned through extended testing.

  14. Characterization of radioactive waste forms. Volume 1

    International Nuclear Information System (INIS)

    Brodersen, K.; Nilsson, K.

    1989-01-01

    This document is the second yearbook for Task 3 of the European Communities 1985-89 programme of research on radioactive waste management and disposal carried out by public organizations and private firms in the Community through costsharing contracts with the Commission of the European Communities. The report, in two volumes, describes progress made in 1987 within the field of Task 3: Testing and evaluation of conditioned waste and engineered barriers. The first volume of the report covers Item 3.1 Characterization of low and medium-level radioactive waste forms and Item 3.5 Development of test methods for quality assurance. The second volume covers Item 3.2: High-level and alpha waste characterization and Item 3.3: Other engineered barriers. Item 3.4 on the round robin study will be treated in a separate report

  15. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  16. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  17. Case volumes of intra-arterial and intravenous treatment of ischemic stroke in the USA.

    Science.gov (United States)

    Hirsch, J A; Yoo, A J; Nogueira, R G; Verduzco, L A; Schwamm, L H; Pryor, J C; Rabinov, J D; González, R G

    2009-07-01

    Ischemic stroke is a major cause of disability and death in the USA. Intravenous tissue plasminogen activator (t-PA) remains underutilized. With the development of newer intra-arterial reperfusion therapies, there is increased opportunity to address the more devastating large-vessel occlusions. We seek to identify the numbers of patients with stroke treated with intravenous and intra-arterial therapies, as well as to estimate the potential number of intra-arterial cases in the foreseeable future. We performed a literature search to determine case volumes of intravenous t-PA use. We extrapolated the current case volume of intra-arterial stroke therapies from the numbers of cases in which the Merci retrieval device was used. In order to estimate the potential numbers of intra-arterial stroke cases, we characterized the percentage of patients with stroke who received intra-arterial therapy at two leading stroke centers. We applied these percentages to the numbers of patients with stroke seen at the top 100, 200 and 500 stroke centers by volume. The rate of intravenous t-PA use is 2.4-3.6%, resulting in 15 000-22 000 cases/year in the USA. The estimated case volume of intra-arterial therapies is 3500-7200 in 2006. Based on data from St. Luke's Brain and Stroke Institute and Massachusetts General Hospital, approximately 5-20% of patients with ischemic stroke can be treated with intra-arterial therapies. Extrapolating this to the top 500 stroke centers by volume, the potential number of intra-arterial cases in the USA is 10 400-41 500/year. Based on the current numbers of intra-arterial cases, our theoretical model identifies a potential for significant growth of this stroke therapy.

  18. Measurement of lung volumes : usefulness of spiral CT

    International Nuclear Information System (INIS)

    Kang, Ho Yeong; Kwak, Byung Kook; Lee, Sang Yoon; Kim, Soo Ran; Lee, Shin Hyung; Lee, Chang Joon; Park, In Won

    1996-01-01

    To evaluate the usefulness of spiral CT in the measurement of lung volumes. Fifteen healthy volunteers were studied by both spirometer and spiral CT at full inspiration and expiration in order to correlated their results, including total lung capacity (TLC), vital capacity (VC) and residual volume (RV). 3-D images were reconstructed from spiral CT, and we measured lung volumes at a corresponding CT window range ; their volumes were compared with the pulmonary function test (paired t-test). The window range corresponding to TLC was from -1000HU to -150HU (p=0.279, r=0.986), and for VC from -910HU to -800HU (p=0.366, r=0.954) in full-inspiratory CT. The optimal window range for RV in full-expiratory CT was from -1000HU to -450HU (p=0.757, r=0.777), and TLC-VC in full-inspiratory CT was also calculated (p=0.843, r=0.847). Spiral CT at full inspiration can used to lung volumes such as TLC, VC and RV

  19. Selected topics in particle accelerators: Proceedings of the CAP meetings. Volume 4

    International Nuclear Information System (INIS)

    Parsa, Z.

    1995-01-01

    This Report includes copies of transparencies and notes from the presentations made at the Center for Accelerator Physics at Brookhaven National Laboratory. Editing and changes to the authors' contributions in this Report were made only to fulfill the publication requirements. This volume includes notes and transparencies on eight presentations: ''Application of Accelerator-Driven Spallation Targets - Including Tritium Production and Nuclear Waste Transmutation'', ''BNL 5 MW Pulsed Spallation Neutron Source Study'', ''Designing and Understanding of Magnets with the Help of Conformal Mapping'', ''Laser - Electron Beam Scattering Coherent Compton X-Ray Sources'', ''The LHC Project'', ''Optimization of the Photocathode-Linac Separation for the ATF [Accelerator Test Facility] Injection System'', ''On CEBAF Commissioning: First Results'', and ''The Proposed Booster Application Facility at BNL''. An Appendix lists dates, topics, and speakers from October 1989 to December 1994

  20. Measuring the volume of caudate nucleus in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Ni Mingfei; Chen Nan; Wang Xing; Wu Jianlin; Li Kuncheng; Zhou Xin; Zhou Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of the caudate nucleus' volume in Chinese adults of the Han nationality and provide morphological data for the construction of database for Chinese Standard Brain. Methods: This was a clinical multi-center study. One thousand Chinese healthy volunteers (age range =18 to 70) recruited from 16 hospitals were divided into 5 groups, i.e, Group A (age range = 18 to 30), B (age range =31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range =61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. The volume of caudate was measured manually using 3D volume analysis software. The difference of volumes of the caudate between male and female were analyzed by independent sample t-test, and among age groups by ANOVA. Pearson's correlation coefficient was used to characterize the relationship between volumes and age. The differences of measurements between left and right caudate nucleus were analyzed by paired t test. Results: (1) The mean volume of bilateral caudate nucleus in healthy Chinese adults was (10.973± 1.647) cm 3 . The mean volume of the the male's left and right caudate nucleus were (5.656±0.860) and (5.671±0.855) cm 3 respectively,no significant differences were found between the volume of left and right caudate nucleus (t=1.230, P>0.05). The mean volume of the the female's left and right caudate nucleus were (5.287±0.774) and (5.331±0.766) cm 3 respectively, and the right's was larger than the left's with significant differences (t=3.999, P<0.01); (2) Pearson correlation analysis showed a significant negative correlation between the nucleus volume and age (male and female's, left and right) (r=-0.561, -0.568, -0.548, -0.552, P<0.05). Conclusion: With high-resolution MRI and 3D volumetric analytic software (Midob), the volume of the caudate nucleus can be

  1. Procedure for implementing the system of quality management in the testing laboratory of the Center for Genetic Engineering and Biotechnology in Sancti Spiritus.

    Directory of Open Access Journals (Sweden)

    Lídice Peraza Cruz

    2014-03-01

    Full Text Available Implementation of Quality Management System in testing laboratories offers the possibility of its accreditation and a frame for cooperation with other organizations, supporting information and experience exchange, as well as standards and procedures harmonization. To improve the performance of the Center for Genetic Engineering and Biotechnology of Sancti Spíritus testing laboratory, assuring technically valid data and results which promote technical competence and credibility of in vitro diagnostics and biological reagents products, a procedure was designed to implement a Quality Management System. This procedure applies Deming´s Quality Cycle and considers all relevant requirements in NC ISO/IEC 17025:2006 “General requirements for the competence of testing and calibration laboratories” and Regulation No. 20 2004 “Good Manufacturing Practices for in vitro Diagnostics” of Center for State Control of Drugs, Equipment and Medical Devices. We recommend an auto evaluation method, designed by authors, to verify quality management system accomplishment.

  2. Volume and mass measurements of liquids

    International Nuclear Information System (INIS)

    Zander, M.

    1987-12-01

    The report comprises the 10 lectures given at the 74th PTB seminar, which represent the state of the art in the field of liquid flow measurement. The lectures deal with the overflow-pipette as the primary volume standard of PTB, gas elimination devices (compulsory in measuring assemblies with volume meters), measuring assemblies for the reception of milk, electromagnetic flowmeters, vortex-shedding meters, indirect mass measurement from volume and density, direct mass measurement (coriolis flowmeters), pipeline-measurements, level measurement at storage tanks with conventional and optical methods and a development aid project for the set up of test rigs in India. (orig.) [de

  3. How Well Are American Students Learning? With Sections on Reading and Math in the Common Core Era, Tracking and Advanced Placement (AP), and Principals as Instructional Leaders. The 2016 Brown Center Report on American Education. Volume 3, Number 5

    Science.gov (United States)

    Loveless, Tom

    2016-01-01

    The 2016 edition of the Brown Center Report (BCR) is number five in the third volume and the 15th issue overall. As is customary, this year's BCR contains three studies. Part one is on the Common Core State Standards (CCSS) and instruction in math and reading. National Assessment of Educational Progress (NAEP) data indicate that nonfiction is…

  4. Large volume cryogenic silicon detectors

    International Nuclear Information System (INIS)

    Braggio, C.; Boscardin, M.; Bressi, G.; Carugno, G.; Corti, D.; Galeazzi, G.; Zorzi, N.

    2009-01-01

    We present preliminary measurements for the development of a large volume silicon detector to detect low energy and low rate energy depositions. The tested detector is a one cm-thick silicon PIN diode with an active volume of 31 cm 3 , cooled to the liquid helium temperature to obtain depletion from thermally-generated free carriers. A thorough study has been done to show that effects of charge trapping during drift disappears at a bias field value of the order of 100V/cm.

  5. Microstructure-Aided Digital Volume Correlation

    Directory of Open Access Journals (Sweden)

    Hild F.

    2010-06-01

    Full Text Available This paper describes how volumic images of a composite material could be used to measure 3D displacement fields, and assess mechanical properties. The exemple of a tensile test performed on a sample made of an energetic material is chosen. Different tools are used, namely, X-ray microtomography of an in situ experiment, image acquisition and processing, volume correlation to measure 3D displacement fields. The principle of an integrated approach is finally introduced.

  6. Red Blood Cell Mechanical Fragility Test for Clinical Research Applications.

    Science.gov (United States)

    Ziegler, Luke A; Olia, Salim E; Kameneva, Marina V

    2017-07-01

    Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a "standard" value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R 2  = 0.923) of MFI if performed with the reduced volume RBT at "standard" (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI-reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Center for Space Power, Texas A and M University

    Science.gov (United States)

    Jones, Ken

    Johnson Controls is a 106 year old company employing 42,000 people worldwide with $4.7 billion annual sales. Though we are new to the aerospace industry we are a world leader in automobile battery manufacturing, automotive seating, plastic bottling, and facilities environment controls. The battery division produces over 24,000,000 batteries annually under private label for the new car manufacturers and the replacement market. We are entering the aerospace market with the nickel hydrogen battery with the help of NASA's Center for Space Power at Texas A&M. Unlike traditional nickel hydrogen battery manufacturers, we are reaching beyond the space applications to the higher volume markets of aircraft starting and utility load leveling. Though space applications alone will not provide sufficient volume to support the economies of scale and opportunities for statistical process control, these additional terrestrial applications will. For example, nickel hydrogen batteries do not have the environmental problems of nickel cadmium or lead acid and may someday start your car or power your electric vehicle. However you envision the future, keep in mind that no manufacturer moves into a large volume market without fine tuning their process. The Center for Space Power at Texas A&M is providing indepth technical analysis of all of the materials and fabricated parts of our battery as well as thermal and mechanical design computer modeling. Several examples of what we are doing with nickel hydrogen chemistry to lead to these production efficiencies are presented.

  8. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume VI. Safety and environmental considerations for licensing

    International Nuclear Information System (INIS)

    1980-06-01

    This volume of the Nonproliferation Alternative Systems Assessment Program report addresses safety and environmental considerations in licensing the principal alternative nuclear reactors and fuel cycles in the United States for large-scale commercial nuclear power plants. In addition, this volume examines the safety and environmental considerations for licensing fuel service centers. These centers, which have been proposed for controlling sensitive fuel-cycle facilities and special nuclear materials, would contain a combination of such facilities as reprocessing plants, fabrication plants, and reactors. For this analysis, two fuel service center concepts were selected - one with power - generating capability and one without

  9. Repeatability of quantitative 18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis.

    Science.gov (United States)

    Kramer, G M; Liu, Y; de Langen, A J; Jansma, E P; Trigonis, I; Asselin, M-C; Jackson, A; Kenny, L; Aboagye, E O; Hoekstra, O S; Boellaard, R

    2018-06-01

    3'-deoxy-3'-[ 18 F]fluorothymidine ( 18 F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative 18 F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of 18 F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five 18 F-FLT repeatability cohorts in solid tumors. 18 F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUV max , SUV mean , SUV peak , proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all 18 F-FLT uptake metrics (R 2  ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUV peak (RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUV max  ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. In multi-center studies

  10. [Target volume margins for lung cancer: internal target volume/clinical target volume].

    Science.gov (United States)

    Jouin, A; Pourel, N

    2013-10-01

    The aim of this study was to carry out a review of margins that should be used for the delineation of target volumes in lung cancer, with a focus on margins from gross tumour volume (GTV) to clinical target volume (CTV) and internal target volume (ITV) delineation. Our review was based on a PubMed literature search with, as a cornerstone, the 2010 European Organisation for Research and Treatment of Cancer (EORTC) recommandations by De Ruysscher et al. The keywords used for the search were: radiotherapy, lung cancer, clinical target volume, internal target volume. The relevant information was categorized under the following headings: gross tumour volume definition (GTV), CTV-GTV margin (first tumoural CTV then nodal CTV definition), in field versus elective nodal irradiation, metabolic imaging role through the input of the PET scanner for tumour target volume and limitations of PET-CT imaging for nodal target volume definition, postoperative radiotherapy target volume definition, delineation of target volumes after induction chemotherapy; then the internal target volume is specified as well as tumoural mobility for lung cancer and respiratory gating techniques. Finally, a chapter is dedicated to planning target volume definition and another to small cell lung cancer. For each heading, the most relevant and recent clinical trials and publications are mentioned. Copyright © 2013. Published by Elsevier SAS.

  11. The irradiation lung volume in tangential fields for the treatment of a breast

    International Nuclear Information System (INIS)

    Oh, Y. T.; Kim, J. R.; Kang, H. J.; Sohn, J. H.; Kang, S. H.; Chun, M. S.

    1997-01-01

    Radiation pneumonitis is one of the complications caused by radiation therapy that includes a portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying pulmonary function. The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan. 1995 to Aug. 1996. Parameters that can predict the irradiated lung volume included; (1) the perpendicular distance from the posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD); (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); (3) the greatest perpendicular distance from the posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD); (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The RV is 61-279cc, the RV/EV is 2.9-13.0% and the RV/EN is 4.9-29.6%. The CLD, the MLD and the GPD are 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV, RV/EV, RV/IV and parameters such as CLD, MLD, GPD, L, CLD x L, MLD x L and GPD x L are not found with little variances in parameters. The RV/IV of the left breast irradiation is significances. The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential field is less than 10% of entire lung volume when CLD is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVs. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up. (author)

  12. Recurrence interval analysis of trading volumes.

    Science.gov (United States)

    Ren, Fei; Zhou, Wei-Xing

    2010-06-01

    We study the statistical properties of the recurrence intervals τ between successive trading volumes exceeding a certain threshold q. The recurrence interval analysis is carried out for the 20 liquid Chinese stocks covering a period from January 2000 to May 2009, and two Chinese indices from January 2003 to April 2009. Similar to the recurrence interval distribution of the price returns, the tail of the recurrence interval distribution of the trading volumes follows a power-law scaling, and the results are verified by the goodness-of-fit tests using the Kolmogorov-Smirnov (KS) statistic, the weighted KS statistic and the Cramér-von Mises criterion. The measurements of the conditional probability distribution and the detrended fluctuation function show that both short-term and long-term memory effects exist in the recurrence intervals between trading volumes. We further study the relationship between trading volumes and price returns based on the recurrence interval analysis method. It is found that large trading volumes are more likely to occur following large price returns, and the comovement between trading volumes and price returns is more pronounced for large trading volumes.

  13. Characterization of radioactive waste forms. Volume 2

    International Nuclear Information System (INIS)

    Smith, D.L.; Green, T.H.

    1989-01-01

    This document is the second yearbook for Task 3 of the European Communities 1985-89 programme of research on radioactive waste management and disposal carried out by public organizations and private firms in the Community through cost-sharing contracts with the Commission of the European Communities. The report, in two volumes, describes progress made in 1987 within the field of Task 3: Testing and evaluation of conditioned waste and engineered barriers. The first volume of the report covers Item 3.1 Characterization of low and medium level radioactive waste forms and Item 3.5. Development of test methods for quality assurance. The second volume covers Item 3.2: High-level and alpha waste characterization and Item 3.3: Other engineered barriers. Item 3.4 on the round robin study will be treated in a separate report

  14. Correlation of Objective Assessment Data With General Surgery Resident In-Training Evaluation Reports and Operative Volumes.

    Science.gov (United States)

    Abdelsattar, Jad M; AlJamal, Yazan N; Ruparel, Raaj K; Rowse, Phillip G; Heller, Stephanie F; Farley, David R

    2018-05-14

    Faculty evaluations, ABSITE scores, and operative case volumes often tell little about true resident performance. We developed an objective structured clinical examination called the Surgical X-Games (5 rooms, 15 minutes each, 12-15 tests total, different for each postgraduate [PGY] level). We hypothesized that performance in X-Games will prove more useful in identifying areas of strength or weakness among general surgery (GS) residents than faculty evaluations, ABSITE scores, or operative cases volumes. PGY 2 to 5 GS residents (n = 35) were tested in a semiannual X-Games assessment using multiple simulation tasks: laparoscopic skills, bowel anastomosis, CT/CXR analysis, chest tube placement, etc. over 1 academic year. Resident scores were compared to their ABSITE, in-training evaluation reports, and operating room case numbers. Academic medical center. PGY-2, 3, 4, and 5 GS residents at Mayo Clinic in Rochester, MN. Results varied greatly within each class except for staff evaluations: in-training evaluation reports medians for PGY-2s were 5.3 (range: 5.0-6.0), PGY-3s 5.9 (5.5-6.3), PGY-4s 5.6 (5.0-6.0), and PGY-5s were 6.1 (5.6-6.9). Although ABSITE and operating room case volumes fluctated greatly with each PGY class, only X-Games scores (median: PGY-2 = 82, PGY-3 = 61, PGY-4 = 76, and PGY-5 = 60) correlated positively (p < 0.05) with operative case volume and negatively (p < 0.05) with staff evaluations. X-Games assessment generated wide differentiation of resident performance quickly, inexpensively, and objectively. Although "Minnesota-nice" surgical staff may feel all GS trainees are "above average," objective assessment tells us otherwise. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  15. Advanced Cancer Detection Center

    National Research Council Canada - National Science Library

    Ruckdeschel, John

    1999-01-01

    ... through screening, and the testing of methods to prevent cancer. In addition, the Center created and supports education programs to provide increased cancer awareness and established working collaborations with the James...

  16. Celebrating 25 Years. National Dropout Prevention Center/Network Newsletter. Volume 22, Number 3

    Science.gov (United States)

    Duckenfield, Marty, Ed.

    2011-01-01

    The "National Dropout Prevention Newsletter" is published quarterly by the National Dropout Prevention Center/Network. This issue contains the following articles: (1) Leading the Way in Dropout Prevention; (2) The 15 Effective Strategies in Action; (3) Technology Changes 1986-2011 (Marty Duckenfield); (4) 25 Years of Research and Support…

  17. A satellite-based analysis of the Val d'Agri Oil Center (southern Italy) gas flaring emissions

    Science.gov (United States)

    Faruolo, M.; Coviello, I.; Filizzola, C.; Lacava, T.; Pergola, N.; Tramutoli, V.

    2014-10-01

    In this paper, the robust satellite techniques (RST), a multi-temporal scheme of satellite data analysis, was implemented to analyze the flaring activity of the Val d'Agri Oil Center (COVA), the largest Italian gas and oil pre-treatment plant, owned by Ente Nazionale Idrocarburi (ENI). For this site, located in an anthropized area characterized by a large environmental complexity, flaring emissions are mainly related to emergency conditions (i.e., waste flaring), as industrial processes are regulated by strict regional laws. While regarding the peculiar characteristics of COVA flaring, the main aim of this work was to assess the performances of RST in terms of sensitivity and reliability in providing independent estimations of gas flaring volumes in such conditions. In detail, RST was implemented for 13 years of Moderate Resolution Imaging Spectroradiometer (MODIS) medium and thermal infrared data in order to identify the highly radiant records associated with the COVA flare emergency discharges. Then, using data provided by ENI about gas flaring volumes in the period 2003-2009, a MODIS-based regression model was developed and tested. The results achieved indicate that the such a model is able to estimate, with a good level of accuracy (R2 of 0.83), emitted gas flaring volumes at COVA.

  18. Using Photogrammetry to Estimate Tank Waste Volumes from Video

    Energy Technology Data Exchange (ETDEWEB)

    Field, Jim G. [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2013-03-27

    Washington River Protection Solutions (WRPS) contracted with HiLine Engineering & Fabrication, Inc. to assess the accuracy of photogrammetry tools as compared to video Camera/CAD Modeling System (CCMS) estimates. This test report documents the results of using photogrammetry to estimate the volume of waste in tank 241-C-I04 from post-retrieval videos and results using photogrammetry to estimate the volume of waste piles in the CCMS test video.

  19. Using Photogrammetry to Estimate Tank Waste Volumes from Video

    International Nuclear Information System (INIS)

    Field, Jim G.

    2013-01-01

    Washington River Protection Solutions (WRPS) contracted with HiLine Engineering and Fabrication, Inc. to assess the accuracy of photogrammetry tools as compared to video Camera/CAD Modeling System (CCMS) estimates. This test report documents the results of using photogrammetry to estimate the volume of waste in tank 241-C-I04 from post-retrieval videos and results using photogrammetry to estimate the volume of waste piles in the CCMS test video

  20. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  1. Prediction of the Individual Wave Overtopping Volumes of a Wave Energy Converter using Experimental Testing and First Numerical Model Results

    DEFF Research Database (Denmark)

    Victor, L.; Troch, P.; Kofoed, Jens Peter

    2009-01-01

    For overtopping wave energy converters (WECs) a more efficient energy conversion can be achieved when the volumes of water, wave by wave, that enter their reservoir are known and can be predicted. A numerical tool is being developed using a commercial CFD-solver to study and optimize...... nearshore 2Dstructure. First numerical model results are given for a specific test with regular waves, and are compared with the corresponding experimental results in this paper....

  2. Solid and liquid radioactive waste management of the Nuclear Technology Development Center (CDTN) - NUCLEBRAS

    International Nuclear Information System (INIS)

    Guzella, M.F.R.; Miaw, S.T.W.; Mourao, R.P.; Prado, M.A.S. do; Reis, L.C.A.; Santos, P.O.; Silva, E.M.P.

    1986-01-01

    Low level liquid and solid wastes are produced in several laboratories of the NUCLEAR TECHNOLOGY DEVELOPMENT CENTER (CDTN)-NUCLEBRAS. In the last years, the intensification of technical activities at the Center has increased the radioactive waste volumes. Therefore, the implementation of a Radioactive Waste Management Program has begun. This Program includes the systematic of activities from the waste collection to the transportation for the final disposal. The liquid and solid waste are collected separately in proper containers and stored for later treatment according to the processes available or under development at the Center. (Author) [pt

  3. Solid and liquid radioactive waste management of the Nuclear Technology Development Center (CDTN)- Nuclebras

    International Nuclear Information System (INIS)

    Guzella, M.F.R.; Mourao, R.P.; Reis, L.C.A.; Silva, E.M.P.; Miaw, S.T.W.; Prado, M.A.S.; Santos, P.O.

    1986-01-01

    Low level liquid and solid wastes are produced in several laboratories of the NUCLEAR TECHNOLOGY DEVELOPMENT CENTER (CDTN) - NUCLEBRAS. In the last years, the intensification of technical activities at the Center has increased the radioactive waste volumes. Therefore, the implementation of a Radioactive Waste Management Program has begun. This Program includes the systematic of activities from the waste collection to the transportation for the final disposal. The liquid and solid waste are collected separately in proper containers and stored for later treatment according to the processes available or under development at the Center. (Author) [pt

  4. [Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center].

    Science.gov (United States)

    Men, Shou-Shan; Lv, Lian-Zhi; Chen, Yuan-Feng; Han, Chun-Hua; Liu, Hong-Yu; Yan, Yan

    2017-12-01

    To investigate the blood test patterns for blood donors after nucleic acid detection in blood center. The collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBV + persons the serological test yet should be performed. In 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV + (0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV + (1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV + (1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBV + by 6-fold dilution for virus concentration found only 4 samples with HBV + . In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ 2 =8.11, P0.05). In 41 samples with HBsAg - HBV DNA + detected by ELISA, 36 samples were confirmed to be occult HBV

  5. PATRAM '80. Proceedings. Volume 2

    International Nuclear Information System (INIS)

    Huebner, H.W.

    1980-01-01

    Volume 2 contains papers from the following sessions: Safeguards-Related Problems; Neutronics and Criticality; Operations and Systems Experience II; Plutonium Systems; Intermediate Storage in Casks; Operations and Systems Planning; Institutional Issues; Structural and Thermal Evaluation I; Poster Session B; Extended Testing I; Structural and Thermal Evaluation II; Extended Testing II; and Emergency Preparedness and Response. Individual papers were processed. (LM)

  6. Large volume cryogenic silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Braggio, C. [Dipartimento di Fisica, Universita di Padova, via Marzolo 8, 35131 Padova (Italy); Boscardin, M. [Fondazione Bruno Kessler (FBK), via Sommarive 18, I-38100 Povo (Italy); Bressi, G. [INFN sez. di Pavia, via Bassi 6, 27100 Pavia (Italy); Carugno, G.; Corti, D. [INFN sez. di Padova, via Marzolo 8, 35131 Padova (Italy); Galeazzi, G. [INFN lab. naz. Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Zorzi, N. [Fondazione Bruno Kessler (FBK), via Sommarive 18, I-38100 Povo (Italy)

    2009-12-15

    We present preliminary measurements for the development of a large volume silicon detector to detect low energy and low rate energy depositions. The tested detector is a one cm-thick silicon PIN diode with an active volume of 31 cm{sup 3}, cooled to the liquid helium temperature to obtain depletion from thermally-generated free carriers. A thorough study has been done to show that effects of charge trapping during drift disappears at a bias field value of the order of 100V/cm.

  7. Test Platform for Advanced Digital Control of Brushless DC Motors (MSFC Center Director's Discretionary Fund)

    Science.gov (United States)

    Gwaltney, D. A.

    2002-01-01

    A FY 2001 Center Director's Discretionary Fund task to develop a test platform for the development, implementation. and evaluation of adaptive and other advanced control techniques for brushless DC (BLDC) motor-driven mechanisms is described. Important applications for BLDC motor-driven mechanisms are the translation of specimens in microgravity experiments and electromechanical actuation of nozzle and fuel valves in propulsion systems. Motor-driven aerocontrol surfaces are also being utilized in developmental X vehicles. The experimental test platform employs a linear translation stage that is mounted vertically and driven by a BLDC motor. Control approaches are implemented on a digital signal processor-based controller for real-time, closed-loop control of the stage carriage position. The goal of the effort is to explore the application of advanced control approaches that can enhance the performance of a motor-driven actuator over the performance obtained using linear control approaches with fixed gains. Adaptive controllers utilizing an exact model knowledge controller and a self-tuning controller are implemented and the control system performance is illustrated through the presentation of experimental results.

  8. Modernization of NASA's Johnson Space Center Chamber: A Liquid Nitrogen System to Support Cryogenic Vacuum Optical Testing of the James Webb Space Telescope (JWST)

    Science.gov (United States)

    Garcia, Sammy; Homan, Jonathan; Montz, Michael

    2016-01-01

    NASA is the mission lead for the James Webb Space Telescope (JWST), the next of the “Great Observatories”, scheduled for launch in 2018. It is directly responsible for the integration and test (I&T) program that will culminate in an end-to-end cryo vacuum optical test of the flight telescope and instrument module in Chamber A at NASA Johnson Space Center. Historic Chamber A is the largest thermal vacuum chamber at Johnson Space Center and one of the largest space simulation chambers in the world. Chamber A has undergone a major modernization effort to support the deep cryogenic, vacuum and cleanliness requirements for testing the JWST. This paper describes the steps performed in efforts to convert the existing the 60’s era Liquid Nitrogen System from a forced flow (pumped) process to a natural circulation (thermo-siphon) process. In addition, the paper will describe the dramatic conservation of liquid nitrogen to support the long duration thermal vacuum testing. Lastly, describe the simplistic and effective control system which results in zero to minimal human inputs during steady state conditions.

  9. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben Thade; Mouridsen, Kim; Golay, Xavier

    2010-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...... and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  10. The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test-retest study

    DEFF Research Database (Denmark)

    Petersen, Esben; Mouridsen, Kim; Golay, Xavier

    2009-01-01

    Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated...... and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing...

  11. Scale Model Acoustic Test Validation of IOP-SS Water Prediction using Loci-STREAM-VoF

    Science.gov (United States)

    Nielsen, Tanner; West, Jeff

    2015-01-01

    The Scale Model Acoustic Test (SMAT) is a 5% scale test of the Space Launch System (SLS), which is currently being designed at Marshall Space Flight Center (MSFC). SMAT consists of a 5% scale representation of the ignition overpressure sound-suppression system (IOP-SS) that is being tested to quantify the water flow and induced air entrainment in and around the mobile launcher exhaust hole. This data will be compared with computational fluid dynamics (CFD) simulations using the newly developed Loci-STREAM Volume of Fluid (VoF) methods. Compressible and incompressible VoF methods have been formulated, and are currently being used to simulate the water flow of SMAT IOP-SS. The test data will be used to qualitatively and quantitatively assess and validate the VoF methods.

  12. Center-Specific Factors Associated with Peritonitis Risk-A Multi-Center Registry Analysis.

    Science.gov (United States)

    Nadeau-Fredette, Annie-Claire; Johnson, David W; Hawley, Carmel M; Pascoe, Elaine M; Cho, Yeoungjee; Clayton, Philip A; Borlace, Monique; Badve, Sunil V; Sud, Kamal; Boudville, Neil; McDonald, Stephen P

    ♦ Previous studies have reported significant variation in peritonitis rates across dialysis centers. Limited evidence is available to explain this variability. The aim of this study was to assess center-level predictors of peritonitis and their relationship with peritonitis rate variations. ♦ All incident peritoneal dialysis (PD) patients treated in Australia between October 2003 and December 2013 were included. Data were accessed through the Australia and New Zealand Dialysis and Transplant Registry. The primary outcome was peritonitis rate, evaluated in a mixed effects negative binomial regression model. Peritonitis-free survival was assessed as a secondary outcome in a Cox proportional hazards model. ♦ Overall, 8,711 incident PD patients from 51 dialysis centers were included in the study. Center-level predictors of lower peritonitis rates included smaller center size, high proportion of PD, low peritoneal equilibration test use at PD start, and low proportion of hospitalization for peritonitis. In contrast, a low proportion of automated PD exposure, high icodextrin exposure and low or high use of antifungal prophylaxis at the time of peritonitis were associated with a higher peritonitis rate. Similar results were obtained for peritonitis-free survival. Overall, accounting for center-level characteristics appreciably decreased peritonitis variability among dialysis centers (p = 0.02). ♦ This study identified specific center-level characteristics associated with the variation in peritonitis risk. Whether these factors are directly related to peritonitis risk or surrogate markers for other center characteristics is uncertain and should be validated in further studies. Copyright © 2016 International Society for Peritoneal Dialysis.

  13. Intra-aortic balloon shape change: effects on volume displacement during inflation and deflation.

    Science.gov (United States)

    Khir, Ashraf William; Bruti, Gianpaolo

    2013-07-01

    It has been observed that operating the intra-aortic balloon at an angle to the horizontal resulted in a reduction of the volume displaced toward the coronary arteries and compromised afterload reduction. Therefore, the aim of this work is to examine whether changing the current balloon shape, which has not been altered for 40 years, could compensate for the negative hemodynamic effects due to angulation. We tested two tapered balloons, increasing diameter (TID) and decreasing diameter (TDD), and compared the results with those obtained from a standard cylindrical balloon. The balloons were tested in vitro at 60 beats/min and a static pressure of 90 mm Hg. The balloons were operated at four angles (0°, 20°, 30°, 45°), and the pressure at three locations along the balloon (base, middle, and tip) was also measured. Flow rate upstream of the tip of the balloon was also measured to indicate the flow displaced toward the coronary circulation. The relative volume displaced toward (VUTVi) and suctioned away from (VUTVd) the simulated ascending aorta, during inflation and deflation, respectively, is reduced when a standard cylindrical balloon is operated at an angle to the horizontal. The TDD provided the greatest VUTVi and also produced the largest pulse pressure during deflation. Although the TID provided less VUTVi and VUTVd at smaller angles, it was not markedly affected by the change of angle. According to these results, different balloon shapes analyzed, with comparable volume to that of a cylindrical balloon, produced greater inflation and deflation benefits, at the horizontal and at a range of angles to the horizontal. Further investigations are required to optimize the shape of the tapered balloons to fit into the available physiological space. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  14. Evaluation of Maxim Module-Integrated Electronics at the DOE Regional Test Centers: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deline, C.; Sekulic, B.; Stein, J.; Barkaszi, S.; Yang, J.; Kahn, S.

    2014-07-01

    Module-embedded power electronics developed by Maxim Integrated are under evaluation through a partnership with the Department of Energy's Regional Test Center (RTC) program. Field deployments of both conventional modules and electronics-enhanced modules are designed to quantify the performance advantage of Maxim's products under different amounts of inter-row shading, and their ability to be deployed at a greater ground-coverage-ratio than conventional modules. Simulations in PVSYST have quantified the predicted performance difference between conventional modules and Maxim's modules from inter-row shading. Initial performance results have identified diffuse irradiance losses at tighter row spacing for both the Maxim and conventional modules. Comparisons with published models show good agreement with models predicting the greatest diffuse irradiance losses. At tighter row spacing, all of the strings equipped with embedded power electronics outperformed their conventional peers. An even greater performance advantage is predicted to occur in the winter months when the amount of inter-row shading mismatch is at a maximum.

  15. Early failure analysis of machining centers: a case study

    International Nuclear Information System (INIS)

    Wang Yiqiang; Jia Yazhou; Jiang Weiwei

    2001-01-01

    To eliminate the early failures and improve the reliability, nine ex-factory machining centers are traced under field conditions in workshops. Their early failure information throughout the ex-factory run-in test is collected. The field early failure database is constructed based on the collection of field early failure data and the codification of data. Early failure mode and effects analysis is performed to indicate the weak subsystem of a machining center or the troublemaker. The distribution of the time between early failures is analyzed and the optimal ex-factory run-in test time for machining center that may expose sufficiently the early failures and cost minimum is discussed. Suggestions how to arrange ex-factory run-in test and how to take actions to reduce early failures for machining center is proposed

  16. Verifying seismic design of nuclear reactors by testing. Volume 1: test plan

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-20

    This document sets forth recommendations for a verification program to test the ability of operational nuclear power plants to achieve safe shutdown immediately following a safe-shutdown earthquake. The purpose of the study is to develop a program plan to provide assurance by physical demonstration that nuclear power plants are earthquake resistant and to allow nuclear power plant operators to (1) decide whether tests should be conducted on their facilities, (2) specify the tests that should be performed, and (3) estimate the cost of the effort to complete the recommended test program.

  17. Verifying seismic design of nuclear reactors by testing. Volume 1: test plan

    International Nuclear Information System (INIS)

    1979-01-01

    This document sets forth recommendations for a verification program to test the ability of operational nuclear power plants to achieve safe shutdown immediately following a safe-shutdown earthquake. The purpose of the study is to develop a program plan to provide assurance by physical demonstration that nuclear power plants are earthquake resistant and to allow nuclear power plant operators to (1) decide whether tests should be conducted on their facilities, (2) specify the tests that should be performed, and (3) estimate the cost of the effort to complete the recommended test program

  18. Improving communication skill training in patient centered medical practice for enhancing rational use of laboratory tests: The core of bioinformation for leveraging stakeholder engagement in regulatory science.

    Science.gov (United States)

    Moura, Josemar de Almeida; Costa, Bruna Carvalho; de Faria, Rosa Malena Delbone; Soares, Taciana Figueiredo; Moura, Eliane Perlatto; Chiappelli, Francesco

    2013-01-01

    Requests for laboratory tests are among the most relevant additional tools used by physicians as part of patient's health problemsolving. However, the overestimation of complementary investigation may be linked to less reflective medical practice as a consequence of a poor physician-patient communication, and may impair patient-centered care. This scenario is likely to result from reduced consultation time, and a clinical model focused on the disease. We propose a new medical intervention program that specifically targets improving the patient-centered communication of laboratory tests results, the core of bioinformation in health care. Expectations are that medical students training in communication skills significantly improve physicians-patient relationship, reduce inappropriate use of laboratorial tests, and raise stakeholder engagement.

  19. Energy Survey of Eisenhower Army Medical Center, Fort Gordon, Augusta, Georgia. Volume 2. Appendices

    National Research Council Canada - National Science Library

    1996-01-01

    ...) including low cost/no cost ECO's and perform complete evaluations of each. Energy equipment replacement projects already underway, approved, or planned by the Medical Center staff will be factored into the evaluations...

  20. Assessment of tidal volume and thoracoabdominal motion using volume and flow-oriented incentive spirometers in healthy subjects

    Directory of Open Access Journals (Sweden)

    V.F. Parreira

    2005-07-01

    Full Text Available The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne and flow-oriented (Triflo II and Respirex devices. Sixteen healthy subjects, 24 ± 4 years, 62 ± 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45º. Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 ± 268 vs 947 ± 268 ml, P = 0.02 and minute ventilation (9.07 ± 3.61 vs 7.49 ± 2.58 l/min, P = 0.01 were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 ± 1.24 vs 8.57 ± 1.89 bpm. Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 ± 0.05 vs 0.32 ± 0.05 ml/s, P = 0.00, and 531 ± 137 vs 606 ± 167 ml/s, P = 0.00, respectively. Abdominal motion was larger (P < 0.05 during the use of volume-oriented devices compared to flow-oriented devices (52 ± 11% for Coach and 50 ± 9% for Voldyne; 43 ± 13% for Triflo II and 44 ± 14% for Respirex. We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.

  1. [Blood volume for biochemistry determinations--laboratory needs and everyday practice].

    Science.gov (United States)

    Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław

    2014-01-01

    Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.

  2. Infrared astronomical satellite (IRAS) catalogs and atlases. Volume 1: Explanatory supplement

    Science.gov (United States)

    Beichman, C. A. (Editor); Neugebauer, G. (Editor); Habing, H. J. (Editor); Clegg, P. E. (Editor); Chester, Thomas J. (Editor)

    1988-01-01

    The Infrared Astronomical Satellite (IRAS) was launched on January 26, 1983. During its 300-day mission, IRAS surveyed over 96 pct of the celestial sphere at four infrared wavelengths, centered approximately at 12, 25, 60, and 100 microns. Volume 1 describes the instrument, the mission, and data reduction.

  3. Information on the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Reuter, H.H.

    1980-01-01

    A short overview is given about the origins of Karlsruhe Nuclear Research Center. The historical development of the different companies operating the Center is shown. Because the original task assigned to the Center was the construction and testing of the first German reactor exclusively built by German companies, a detailed description of this reactor and the changes made afterwards is presented. Next, today's organizational structure of the Center is outlined and the development of the Center's financing since its foundation is shown. A short overview about the structure of employees from the Center's beginning up to now is also included as well as a short description of today's main activities. (orig.)

  4. Proceedings of RIKEN BNL Research Center Workshop, Volume 91, RBRC Scientific Review Committee Meeting

    Energy Technology Data Exchange (ETDEWEB)

    Samios,N.P.

    2008-11-17

    The ninth evaluation of the RIKEN BNL Research Center (RBRC) took place on Nov. 17-18, 2008, at Brookhaven National Laboratory. The members of the Scientific Review Committee (SRC) were Dr. Dr. Wit Busza (Chair), Dr. Miklos Gyulassy, Dr. Akira Masaike, Dr. Richard Milner, Dr. Alfred Mueller, and Dr. Akira Ukawa. We are pleased that Dr. Yasushige Yano, the Director of the Nishina Institute of RIKEN, Japan participated in this meeting both in informing the committee of the activities of the Nishina Institute and the role of RBRC and as an observer of this review. In order to illustrate the breadth and scope of the RBRC program, each member of the Center made a presentation on his/her research efforts. This encompassed three major areas of investigation, theoretical, experimental and computational physics. In addition the committee met privately with the fellows and postdocs to ascertain their opinions and concerns. Although the main purpose of this review is a report to RIKEN Management (Dr. Ryoji Noyori, RIKEN President) on the health, scientific value, management and future prospects of the Center, the RBRC management felt that a compendium of the scientific presentations are of sufficient quality and interest that they warrant a wider distribution. Therefore we have made this compilation and present it to the community for its information and enlightenment.

  5. Reliability of tanoak volume equations when applied to different areas

    Science.gov (United States)

    Norman H. Pillsbury; Philip M. McDonald; Victor Simon

    1995-01-01

    Tree volume equations for tanoak (Lithocarpus densiflorus) were developed for seven stands throughout its natural range and compared by a volume prediction and a parameter difference method. The objective was to test if volume estimates from a species growing in a local, relatively uniform habitat could be applied more widely. Results indicated...

  6. Program integration of predictive maintenance with reliability centered maintenance

    International Nuclear Information System (INIS)

    Strong, D.K. Jr; Wray, D.M.

    1990-01-01

    This paper addresses improving the safety and reliability of power plants in a cost-effective manner by integrating the recently developed reliability centered maintenance techniques with the traditional predictive maintenance techniques of nuclear power plants. The topics of the paper include a description of reliability centered maintenance (RCM), enhancing RCM with predictive maintenance, predictive maintenance programs, condition monitoring techniques, performance test techniques, the mid-Atlantic Reliability Centered Maintenance Users Group, test guides and the benefits of shared guide development

  7. Statistical Machines for Trauma Hospital Outcomes Research: Application to the PRospective, Observational, Multi-Center Major Trauma Transfusion (PROMMTT Study.

    Directory of Open Access Journals (Sweden)

    Sara E Moore

    Full Text Available Improving the treatment of trauma, a leading cause of death worldwide, is of great clinical and public health interest. This analysis introduces flexible statistical methods for estimating center-level effects on individual outcomes in the context of highly variable patient populations, such as those of the PRospective, Observational, Multi-center Major Trauma Transfusion study. Ten US level I trauma centers enrolled a total of 1,245 trauma patients who survived at least 30 minutes after admission and received at least one unit of red blood cells. Outcomes included death, multiple organ failure, substantial bleeding, and transfusion of blood products. The centers involved were classified as either large or small-volume based on the number of massive transfusion patients enrolled during the study period. We focused on estimation of parameters inspired by causal inference, specifically estimated impacts on patient outcomes related to the volume of the trauma hospital that treated them. We defined this association as the change in mean outcomes of interest that would be observed if, contrary to fact, subjects from large-volume sites were treated at small-volume sites (the effect of treatment among the treated. We estimated this parameter using three different methods, some of which use data-adaptive machine learning tools to derive the outcome models, minimizing residual confounding by reducing model misspecification. Differences between unadjusted and adjusted estimators sometimes differed dramatically, demonstrating the need to account for differences in patient characteristics in clinic comparisons. In addition, the estimators based on robust adjustment methods showed potential impacts of hospital volume. For instance, we estimated a survival benefit for patients who were treated at large-volume sites, which was not apparent in simpler, unadjusted comparisons. By removing arbitrary modeling decisions from the estimation process and concentrating

  8. Open standards for cascade models for RHIC: Volume 1. Proceedings of RIKEN BNL Research Center workshop

    International Nuclear Information System (INIS)

    1997-01-01

    It is widely recognized that cascade models are potentially effective and powerful tools for interpreting and predicting multi-particle observables in heavy ion physics. However, the lack of common standards, documentation, version control, and accessibility have made it difficult to apply objective scientific criteria for evaluating the many physical and algorithmic assumptions or even to reproduce some published results. The first RIKEN Research Center workshop was proposed by Yang Pang to address this problem by establishing open standards for original codes for applications to nuclear collisions at RHIC energies. The aim of this first workshop is: (1) to prepare a WWW depository site for original source codes and detailed documentation with examples; (2) to develop and perform standardized test for the models such as Lorentz invariance, kinetic theory comparisons, and thermodynamic simulations; (3) to publish a compilation of results of the above work in a journal e.g., ''Heavy Ion Physics''; and (4) to establish a policy statement on a set of minimal requirements for inclusion in the OSCAR-WWW depository

  9. Reduced Albumin Dosing During Large-Volume Paracentesis Is Not Associated with Adverse Clinical Outcomes.

    Science.gov (United States)

    Johnson, Kara B; Mueller, Jessica L; Simon, Tracey G; Zheng, Hui; King, Lindsay Y; Makar, Robert S; Gervais, Debra A; Chung, Raymond T

    2015-07-01

    LVP is used to manage diuretic-resistant ascites in cirrhotic patients. Albumin administration prevents complications including acute kidney injury and paracentesis-induced circulatory dysfunction, but the optimal dose is unclear. We sought to assess adherence to guidelines enacted in July 2011 at our center for reducing the albumin dose administered at large-volume paracentesis (LVP) and evaluate the cost and rate of complications of LVPs before and after guideline enactment. All LVPs performed on cirrhotic patients in our center's Department of Radiology between July 2009 and January 2014 were studied. Outcomes included adherence to guidelines, LVP complications, and administered albumin cost. Groups were compared using Student's t tests for continuous data and Chi-square or Fisher's exact tests for categorical data. A repeated measurements model accounted for patients with multiple LVPs. Of the 935 LVPs, 288 occurred before guideline implementation (group 1) and 647 occurred after (group 2). The mean dose of albumin administered was 13.7 g/L of ascites removed in group 1 versus 10.3 g/L in group 2 (p albumin administration and associated cost savings was still observed. There was no increase in LVP-related complications after guideline implementation or in the adherent group, suggesting that albumin dose can be safely reduced. Future efforts should be directed at enhancing guideline adherence and potentially further reducing albumin dosing.

  10. Couples’ Educational Needs Referred to Ershad and Fazel Health Centers of Tehran for Pre-marriage Tests in 2014

    Directory of Open Access Journals (Sweden)

    ّFarima Mohammadi

    2016-12-01

    Full Text Available Background and Objective: Premarital education is the foundation for the development of couples’ communications, sexual relationships, health and fertility. Therefore, this study was done with the purpose of determining couples’ educational needs referred to Ershad and Fazel health centers of Tehran for pre-marriage tests.Materials and Methods: A Cross Sectional study was conducted among couples who referred to health centers. The sample size was 1672 and the sampling method was convenience.. Demographic data was collected through interview with women based on questionnaires. Then the couples responded to the self-administered educational needs questionnaire. The collected data were entered into SPSS-21 statistical software and analyzed using Chi-Square test.Results: 883 women and 789 men completed the educational needs questionnaire. The mean (SD age of women and men were 27.1 (4.5 and 30.2 (5.3 years respectively. Of all female participants 483 (54.7% and 369 (41.8% of male participants had a bachelor's degree. 97.5% of men and 57.1% of women were employed. The ethnicity of about 72% of participants was Far. Most of the pre-marriage educational needs of men and women were marital health, importance of pre-marriage tests, unintended pregnancy prevention methods, correct marital relationship and prenatal care. 313 (64.6% women and 238 (42.8% men reported the pre-marriage educational class to be very helpful. The educational needs of couples were not different based on education, ethnicity and place of residence.Conclusion: Results of the currents study shows the need for pre-marriage education in all evaluated aspects and the importance of paying attention to it for prospering the pre-marital classes.

  11. MO-D-213-01: Workflow Monitoring for a High Volume Radiation Oncology Center

    International Nuclear Information System (INIS)

    Laub, S; Dunn, M; Galbreath, G; Gans, S; Pankuch, M

    2015-01-01

    Purpose: Implement a center wide communication system that increases interdepartmental transparency and accountability while decreasing redundant work and treatment delays by actively monitoring treatment planning workflow. Methods: Intake Management System (IMS), a program developed by ProCure Treatment Centers Inc., is a multi-function database that stores treatment planning process information. It was devised to work with the oncology information system (Mosaiq) to streamline interdepartmental workflow.Each step in the treatment planning process is visually represented and timelines for completion of individual tasks are established within the software. The currently active step of each patient’s planning process is highlighted either red or green according to whether the initially allocated amount of time has passed for the given process. This information is displayed as a Treatment Planning Process Monitor (TPPM), which is shown on screens in the relevant departments throughout the center. This display also includes the individuals who are responsible for each task.IMS is driven by Mosaiq’s quality checklist (QCL) functionality. Each step in the workflow is initiated by a Mosaiq user sending the responsible party a QCL assignment. IMS is connected to Mosaiq and the sending or completing of a QCL updates the associated field in the TPPM to the appropriate status. Results: Approximately one patient a week is identified during the workflow process as needing to have his/her treatment start date modified or resources re-allocated to address the most urgent cases. Being able to identify a realistic timeline for planning each patient and having multiple departments communicate their limitations and time constraints allows for quality plans to be developed and implemented without overburdening any one department. Conclusion: Monitoring the progression of the treatment planning process has increased transparency between departments, which enables efficient

  12. MO-D-213-01: Workflow Monitoring for a High Volume Radiation Oncology Center

    Energy Technology Data Exchange (ETDEWEB)

    Laub, S [CDH Proton Center, Warrenville, IL (United States); Dunn, M [Proton Collaborative Group, Warrenville, Illinois (United States); Galbreath, G [ProCure Treatment Centers Inc., New York, NY (United States); Gans, S [Northwestern Memorial Chicago Proton Center, Warrenville, Illinois (United States); Pankuch, M [Northwestern Medicine Chicago Proton Center, Warrenville, IL (United States)

    2015-06-15

    Purpose: Implement a center wide communication system that increases interdepartmental transparency and accountability while decreasing redundant work and treatment delays by actively monitoring treatment planning workflow. Methods: Intake Management System (IMS), a program developed by ProCure Treatment Centers Inc., is a multi-function database that stores treatment planning process information. It was devised to work with the oncology information system (Mosaiq) to streamline interdepartmental workflow.Each step in the treatment planning process is visually represented and timelines for completion of individual tasks are established within the software. The currently active step of each patient’s planning process is highlighted either red or green according to whether the initially allocated amount of time has passed for the given process. This information is displayed as a Treatment Planning Process Monitor (TPPM), which is shown on screens in the relevant departments throughout the center. This display also includes the individuals who are responsible for each task.IMS is driven by Mosaiq’s quality checklist (QCL) functionality. Each step in the workflow is initiated by a Mosaiq user sending the responsible party a QCL assignment. IMS is connected to Mosaiq and the sending or completing of a QCL updates the associated field in the TPPM to the appropriate status. Results: Approximately one patient a week is identified during the workflow process as needing to have his/her treatment start date modified or resources re-allocated to address the most urgent cases. Being able to identify a realistic timeline for planning each patient and having multiple departments communicate their limitations and time constraints allows for quality plans to be developed and implemented without overburdening any one department. Conclusion: Monitoring the progression of the treatment planning process has increased transparency between departments, which enables efficient

  13. Learner-Centered Instruction (LCI): Volume 7. Evaluation of the LCI Approach. Final Report.

    Science.gov (United States)

    Pieper, William J.; And Others

    An evaluation of the learner-centered instruction (LCI) approach to training was conducted by comparing the LCI F-111A weapons control systems mechanic/technician course with the conventional Air Force course for the same Air Force specialty code (AFSC) on the following dimensions; job performance of course graduates, man-hour and dollar costs of…

  14. A new electric method for non-invasive continuous monitoring of stroke volume and ventricular volume-time curves

    Directory of Open Access Journals (Sweden)

    Konings Maurits K

    2012-08-01

    Full Text Available Abstract Background In this paper a new non-invasive, operator-free, continuous ventricular stroke volume monitoring device (Hemodynamic Cardiac Profiler, HCP is presented, that measures the average stroke volume (SV for each period of 20 seconds, as well as ventricular volume-time curves for each cardiac cycle, using a new electric method (Ventricular Field Recognition with six independent electrode pairs distributed over the frontal thoracic skin. In contrast to existing non-invasive electric methods, our method does not use the algorithms of impedance or bioreactance cardiography. Instead, our method is based on specific 2D spatial patterns on the thoracic skin, representing the distribution, over the thorax, of changes in the applied current field caused by cardiac volume changes during the cardiac cycle. Since total heart volume variation during the cardiac cycle is a poor indicator for ventricular stroke volume, our HCP separates atrial filling effects from ventricular filling effects, and retrieves the volume changes of only the ventricles. Methods ex-vivo experiments on a post-mortem human heart have been performed to measure the effects of increasing the blood volume inside the ventricles in isolation, leaving the atrial volume invariant (which can not be done in-vivo. These effects have been measured as a specific 2D pattern of voltage changes on the thoracic skin. Furthermore, a working prototype of the HCP has been developed that uses these ex-vivo results in an algorithm to decompose voltage changes, that were measured in-vivo by the HCP on the thoracic skin of a human volunteer, into an atrial component and a ventricular component, in almost real-time (with a delay of maximally 39 seconds. The HCP prototype has been tested in-vivo on 7 human volunteers, using G-suit inflation and deflation to provoke stroke volume changes, and LVot Doppler as a reference technique. Results The ex-vivo measurements showed that ventricular filling

  15. Measuring the volume of cingulate cortex in Chinese normal adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Zhang Chao; Chen Nan; Wang Xing; Li Kuncheng; Zhou Xin; Zhuo Yan; Chen Lin

    2010-01-01

    Objective: To explore the normal range of cingulate cortex volumes of Chinese adults of the Han nationality and its relationship with age, which provide morphological data for the construction of database for Chinese Standard Brain. Methods: This is a clinical multi-center study. One thousand Chinese healthy volunteers (age range = 18 to 70) recruited from 15 hospitals were divided into 5 groups, i.e., Group A (age range = 18 to 30), B (age range =31 to 40), C (age range =41 to 50), D (age range =51 to 60), and E (age range =61 to 70). Each group contained 100 males and 100 females. All of the volunteers were scanned by MR using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. Cingulate cortex volume (including bulk volume and the left/right volume) was measured semi-manually using 3D volume analysis software. Cingulate cortex volumes among age groups were compared by one-way ANOVA. Right and left cingulate cortex volumes between sexualities were analyzed by paired samples t test. The relationship between cingulate cortex volume and age was analyzed by Pearson correlations and regression analysis. Results: Cingulate cortex volumes of male and female were (20 347 ± 2504) and (19 432 ± 2184) mm 3 respectively, and the male's was significantly larger than that of female's (two sample t'-test for independent samples, t'=6.156, P 3 respectively, and those of female's were (10 064 ± 1407) and (9368 ± 1441) mm 3 respectively. The volumes of cingulate cortex were significantly different between right and left in male or female (t=-12.960, -8.511, P 3 ; right: (11212±1442), (11 096±1602), (11 040±1403), (10633±1638), (9604±1522) mm 3 ] had statistical differences (F=16.738, 18.707, P 3 ; right: (10 558± 1325), (10 266 ±1463), (10 100 ± 1497), (9779 ± 1304), (9617 ± 1254) mm 3 ] also had significant differences (F=16.859,7.528,P<0.01). Bilateral cingulate cortex volume in both male and female were negatively

  16. System of automatic control over data Acquisition and Transmission to IGR NNC RK Data Center

    International Nuclear Information System (INIS)

    Komarov, I.I.; Gordienko, D.D.; Kunakov, A.V.

    2005-01-01

    Automated system for seismic and acoustic data acquisition and transmission in real time was established in Data Center IGR NNC RK, which functions very successively. The system monitors quality and volume of acquired information and also controls the status of the system and communication channels. Statistical data on system operation are accumulated in created database. Information on system status is reflected on the Center Web page. (author)

  17. Nuclear proliferation and civilian nuclear power: report of the Nonproliferation Alternative Systems Assessment Program. Volume VI. Safety and environmental considerations for licensing

    International Nuclear Information System (INIS)

    1979-12-01

    Volume 6 of the Nonproliferation Alternative Systems Assessment Program report addresses safety and environmental considerations in licensing the principal alternative nuclear reactors and fuel cycles in the United States for large-scale commercial nuclear power plants. In addition, this volume examines the safety and environmental considerations for licensing fuel service centers. These centers, which have been proposed for controlling sensitive fuel-cycle facilities and special nuclear materials, would contain a combination of such facilities as reprocessing plants, fabrication plants, and reactors. For this analysis, two fuel service center concepts were selected - one with power-generating capability and one without. This volume also provides estimates of the time required for development of large-scale commercial reactor systems to reach the construction permit application stage and for fuel-cycle facilities to reach the operating license application stage, which is a measure of the relative technical status of alternative nuclear systems

  18. A comparison of center-based vs. home-based daily hemodialysis for patients with end-stage renal disease.

    Science.gov (United States)

    Kraus, Michael; Burkart, John; Hegeman, Rebecca; Solomon, Richard; Coplon, Norman; Moran, John

    2007-10-01

    Home hemodialysis has been a therapeutic option for almost 4 decades. The complexity of dialysis equipment has been a factor-limiting adoption of this modality. We performed a feasibility study to demonstrate the safety of center-based vs. home-based daily hemodialysis with the NxStage System One portable hemodialysis device. We also performed a retrospective analysis to determine if clinical effects previously associated with short-daily dialysis were also seen using this novel device. We conducted a prospective, 2-treatment, 2-period, open-label, crossover study of in-center hemodialysis vs. home hemodialysis in 32 patients treated at 6 U.S. centers. The 8-week In-Center Phase (6 days/week) was followed by a 2-week transition period and then followed by the 8-week Home Phase (6 days/week). We retrospectively collected data on hemodialysis treatment parameters immediately preceding the study in a subset of patients. Twenty-six out of 32 patients (81%) successfully completed the study. Successful delivery of at least 90% of prescribed fluid volume (primary endpoint) was achieved in 98.5% of treatments in-center and 97.3% at home. Total effluent volume as a percentage of prescribed volume was between 94% and 100% for all study weeks. The composite rate of intradialytic and interdialytic adverse events per 100 treatments was significantly higher for the In-Center Phase (5.30) compared with the Home Phase (2.10; p=0.007). Compared with the period immediately preceding the study, there were reductions in blood pressure, antihypertensive medications, and interdialytic weight gain. Daily home hemodialysis with a small, easy-to-use hemodialysis device is a viable dialysis option for end-stage renal disease patients capable of self/partner-administered dialysis.

  19. Demonstration, testing, and evaluation of in situ heating of soil. Volume 1, Final report

    International Nuclear Information System (INIS)

    Dev, H.; Enk, J.; Jones, D.; Sabato, W.

    1996-01-01

    This document is a final reports in two volumes. Volume I contains the technical report and Volume II contains appendices with background information and data. In this project approximately 300 cubic yards of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. It was demonstrated that the mass flow rate of the volatile organic chemicals was enhanced in the recovered soil gas as a result of heating

  20. Demonstration, testing, and evaluation of in situ heating of soil. Volume 1, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dev, H.; Enk, J.; Jones, D.; Sabato, W.

    1996-04-05

    This document is a final reports in two volumes. Volume I contains the technical report and Volume II contains appendices with background information and data. In this project approximately 300 cubic yards of clayey soil containing a low concentration plume of volatile organic chemicals was heated in situ by the application of electrical energy. It was shown that as a result of heating the effective permeability of soil to air flow was increased such that in situ soil vapor extraction could be performed. The initial permeability of soil was so low that the soil gas flow rate was immeasurably small even at high vacuum levels. It was demonstrated that the mass flow rate of the volatile organic chemicals was enhanced in the recovered soil gas as a result of heating.