WorldWideScience

Sample records for terminal elimination half-life

  1. Calculation of chemical elimination half-life from blood with an ongoing exposure source: the example of perfluorooctanoic acid (PFOA).

    Science.gov (United States)

    Russell, Mark H; Waterland, Robert L; Wong, Fiona

    2015-06-01

    Determination of the chemical clearance rate from human blood is a critical component of toxicokinetic exposure assessment. Analysis of temporal biomonitoring data without consideration of ongoing exposure results in calculation of apparent elimination half-life values that are longer than the intrinsic value. The intrinsic elimination half-life is solely a function of the rate of elimination while the apparent elimination half-life reflects the processes of both elimination and ongoing exposure. Confusion between intrinsic and apparent half-life values can lead to misinterpretation of biomonitoring data and can result in exaggerated predictions in subsequent modeling efforts. This work provides a review of the first-order equations that have been developed to calculate intrinsic and apparent half-life values and the potential bias that can result from confusing these two values. Published human biomonitoring data for perfluorooctanoic acid (PFOA) are analyzed using these equations to provide examples of low, medium and high bias in determination of the intrinsic elimination half-life from plasma or serum, the components of blood typically analyzed for PFOA. An approach is also provided to estimate the extent of exposure reduction that is indicated by declining longitudinal or cross-sectional biomonitoring data. Based on the evaluation methodology presented in this work, the intrinsic elimination half-life of PFOA in humans is 2.4years, representing the average of independent estimates of 2.5years (95% CI, 2.4-2.7) and 2.3years (95% CI, 2.1-2.4). The declining concentration of PFOA in blood of the general USA adult population represents an estimated exposure reduction of 20-30% over the period 1999-2008. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. The elimination half-life of benzodiazepines and fall risk: two prospective observational studies.

    Science.gov (United States)

    de Vries, Oscar J; Peeters, Geeske; Elders, Petra; Sonnenberg, Caroline; Muller, Majon; Deeg, Dorly J H; Lips, Paul

    2013-11-01

    the STOPP criteria advise against the use of long-acting benzodiazepines (LBs). to study whether LBs are associated with a higher fall risk than short-acting benzodiazepines (SBs) (elimination half-life ≤ 10 h). we used base-line data and prospective fall follow-up from the Longitudinal Aging Study Amsterdam, a longitudinal cohort study including 1,509 community-dwelling older persons (Study 1) and from a separate fall prevention study with 564 older persons after a fall (Study 2). Time to the first fall after inclusion and number of falls in the first year after inclusion were the primary endpoints. both in Study 1 and Study 2 the use of SBs was associated with time to the first fall, hazard ratio (HR) 1.62 (95% CI: 1.03-2.56) and HR 1.64 (95% CI: 1.19-2.26),respectively. LBs were not significantly associated with time to first fall, HR 1.40 (0.85-2.31) and HR 1.08 (0.72-1.62). In both studies, the use of SBs was also associated with number of falls, odds ratio (OR) 1.28 (95% CI: 1.01-1.61) and OR 1.37 (95% CI: 1.10-1.70). LBs were not significantly associated with number of falls, OR 1.23 (0.96-1.57) and 1.10 (0.82-1.48). the use of SBs is not associated with a lower fall risk compared with LBs. The use of both SBs and LBs by old persons should be strongly discouraged.

  3. Phenobarbital administration every eight hours: improvement of seizure management in idiopathic epileptic dogs with decreased phenobarbital elimination half-life.

    Science.gov (United States)

    Stabile, F; Barnett, C R; De Risio, L

    2017-02-18

    Estimated prevalence of canine idiopathic epilepsy is 0.6 per cent in the first-opinion canine population in the UK. Phenobarbital monotherapy has been reported to reduce/eradicate seizure activity in 60-93 per cent of idiopathic epileptic dogs (IEDs). The objective of this study was to evaluate safety and efficacy of the administration of phenobarbital orally every eight hours in IEDs with phenobarbital elimination half-life less than 20 hours. Medical records of 10 IEDs in which steady state trough serum phenobarbital levels were within the reference range and phenobarbital elimination half-life had become less than 20 hours following prolonged administration every 12 hours were reviewed. Side effects and seizure frequency when phenobarbital was administered every 12 hours or 8 hours were compared. In all dogs the side effects of the antiepileptic medication treatment improved. When phenobarbital was administered every eight hours, 9/10 dogs experienced improvement in seizure frequency and 8/10 dogs maintained seizure freedom for a period three times longer than the longest interictal interval period previously recorded. Reduction in the severity and number of clusters of seizures was recorded in one of the remaining two dogs. The administration of phenobarbital orally every eight hours in IEDs with decreased phenobarbital elimination half-life appears safe and can improve seizure management. The results of this study were presented in abstract form (poster) for the 28th symposium of the European Society of Veterinary Neurology - European College of Veterinary Neurology (ESVN), September 18-19, 2015, Amsterdam, Netherlands. British Veterinary Association.

  4. Prediction of drug terminal half-life and terminal volume of distribution after intravenous dosing based on drug clearance, steady-state volume of distribution, and physiological parameters of the body.

    Science.gov (United States)

    Berezhkovskiy, Leonid M

    2013-02-01

    The steady state, V(ss), terminal volume of distribution, V(β), and the terminal half-life, t(1/2), are commonly obtained from the drug plasma concentration-time profile, C(p)(t), following intravenous dosing. Unlike V(ss) that can be calculated based on the physicochemical properties of drugs considering the equilibrium partitioning between plasma and organ tissues, t(1/2) and V(β) cannot be calculated that way because they depend on the rates of drug transfer between blood and tissues. Considering the physiological pharmacokinetic model pertinent to the terminal phase of drug elimination, a novel equation that calculates t(1/2) (and consequently V(β)) was derived. It turns out that V(ss), the total body clearance, Cl, equilibrium blood-plasma concentration ratio, r; and the physiological parameters of the body such as cardiac output, and blood and tissue volumes are sufficient for determination of terminal kinetics. Calculation of t(1/2) by the obtained equation appears to be in good agreement with the experimentally observed vales of this parameter in pharmacokinetic studies in rat, monkey, dog, and human. The equation for the determination of the pre-exponent of the terminal phase of C(p)(t) is also found. The obtained equation allows to predict t(1/2) in human assuming that V(ss) and Cl were either obtained by allometric scaling or, respectively, calculated in silico or based on in vitro drug stability measurements. For compounds that have high clearance, the derived equation may be applied to calculate r just using the routine data on Cl, V(ss), and t(1/2), rather than doing the in vitro assay to measure this parameter. Copyright © 2012 Wiley Periodicals, Inc.

  5. Pre-Clinical Intravenous Serum Pharmacokinetics of Albumin Binding and Non-Half-Life Extended Nanobodies®

    Directory of Open Access Journals (Sweden)

    Sven Hoefman

    2015-07-01

    Full Text Available Nanobodies are antigen-binding, single variable domain proteins derived from naturally-occurring, heavy chain only antibodies. They are highly soluble, stable, and can be linked to build multi-specific formats. Several Nanobodies are currently in clinical development in different therapeutic areas, for both chronic and acute applications. For the former, prolonged exposure is achieved by half-life extending moieties that target endogenous albumin, while for the latter, non-half-life extended constructs are preferable. To demonstrate the general pharmacokinetic behavior of both formats, serum levels of seven intravenously administered Nanobodies were analyzed in cynomolgus monkeys, mice or rabbits. In monkeys, the total clearance of a monomeric irrelevant Nanobody was rapid (2.0 mL/(min*kg and approximated the species glomerular filtration rate, indirectly suggesting that the Nanobody was mainly eliminated via the kidneys. When linked to an anti-albumin Nanobody, a 376-fold decrease in clearance was observed, resulting in a terminal half-life of 4.9 days, corresponding to the expected species albumin half-life. Similar conclusions were drawn for (non- half-life extended mono-, bi- and trimeric Nanobodies in mice or rabbits, suggesting that these kinetic principles apply across species. Applying this knowledge to species translation and study design is crucial for successful pre-clinical development of novel therapeutic Nanobody candidates.

  6. Half-life of 230Th

    International Nuclear Information System (INIS)

    Meadows, J.W.; Armani, R.J.; Callis, E.L.; Essling, A.M.

    1980-01-01

    The half-life of 230 Th was measured by the specific activity method. Alpha counting was done in a low geometry counter whose geometry factor was calculated from its dimensions. Sample weights were determined by isotopic dilution. Measurements were made on four isotopic mixtures ranging from 0.383 to 99.52% 230 Th. The half-life is 75381 +- 295 years

  7. Half-life measurement of 89Rb

    International Nuclear Information System (INIS)

    Guo Xiaoqing; Yuan Daqing; Xu Lijun; Chen Kesheng; Wu Yongle; Zheng Yanming; Yao Shunhe

    2013-01-01

    89 Rb is an important fission product used for monitoring possible release of fission products from fuel element. The half-life is one of important nuclear parameters. The half-life of 89 Rb was determined using reference source method with two sets of HPGe detectors by place-relay way. In reference source method, the ratio of net full- energy peak areas from the measure nuclide and the reference source was used to avoid the count correction caused by dead time and pileup. For the very short half-life of 89 Rb, the half-life iterative method was used in data analysis and the translation method was used in data unification. Finally, the measured half-life of 89 Rb is (14.41±0.04) min. (authors)

  8. Half-life determination of 125I

    International Nuclear Information System (INIS)

    De Felice, P.; Ientile, P.; Zicari, C.

    1990-01-01

    The half-life of 125 I was determined by measuring the activity of an initial 3 kBq source at several times. Over a period of two months, 96 absolute measurements were performed, using the sum-peak method to give a half-life of (59.38±0.03) d. A discussion is presented on the effect of correcting for accidental coincidences on the half-life measurements by comparing the results with and without this correction. (orig.)

  9. Half Life Measurements in 155Gd

    International Nuclear Information System (INIS)

    Malmskog, S.G.

    1966-08-01

    In the literature there exists a definite difference for the half life of the 86.5 keV level in Gd depending on whether 155 Eu or 155 Tb sources have been used. Using a good energy resolution electron-electron coincidence spectrometer and a 155 Eu source, a half life of 6.48 ± 0.26 nsec was obtained for the 86.5 keV level. This is in agreement with the values previously measured with 155 Tb sources. The half life of the 105.4 keV level was measured to be 1.12 ± 0.05 nsec

  10. Half Life Measurements in {sup 155}Gd

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1966-08-15

    In the literature there exists a definite difference for the half life of the 86.5 keV level in Gd depending on whether {sup 155}Eu or {sup 155}Tb sources have been used. Using a good energy resolution electron-electron coincidence spectrometer and a {sup 155}Eu source, a half life of 6.48 {+-} 0.26 nsec was obtained for the 86.5 keV level. This is in agreement with the values previously measured with {sup 155}Tb sources. The half life of the 105.4 keV level was measured to be 1.12 {+-} 0.05 nsec.

  11. 243Cm half-life determinaton

    International Nuclear Information System (INIS)

    Timofeev, G.A.; Kalygin, V.V.; Privalova, P.A.

    1986-01-01

    By molar ratios of 243 Cm mixture with 244 Cm and Pu nuclides formed as a result of Cm nuclides α-decay the 243 Cm half-life T α243 is determined. The 244 Cm half-life is measured earlier with high accuracy. The 243 Cm/ 244 Cm ratio measured by means of a mass spectrometer equals 0.989+-0.004. The obtained value T α243 =29.20+-0.14 years

  12. Terminal elimination half-lives of the brominated flame retardants TBBPA, HBCD, and lower brominated PBDEs in humans

    Energy Technology Data Exchange (ETDEWEB)

    Geyer, H.J.; Schramm, K.W.; Feicht, E.A.; Fried, K.W.; Henkelmann, B.; Lenoir, D. [GSF-National Research Center, Institute of Ecological Chemistry, Neuherberg (Germany); Darnerud, P.O.; Aune, M. [Swedish National Food Administration, Uppsala (Sweden); Schmid, P. [Swiss Federal Laboratories for Materials Testing and Research, Laboratory of Organic Chemistry, EMPA Duebendorf (Switzerland); McDonald, T.A. [Office of Environmental Health Assessment, California EPA, Oakland, CA (United States)

    2004-09-15

    Brominated flame retardants (BFRs) are widely used in polymers and textiles and applied in electronic equipment, construction materials, and furniture for the purpose of fire prevention. BFRs with the highest production volume are tetrabromobisphenol A (TBBPA), 1,2,5,6,9,10- hexabromocyclododecanes (HBCDs: {alpha}-HBCD + {beta}-HBCD + {gamma}-HBCD), and polybrominated diphenyl ethers (PBDEs). Several BFRs are highly lipophilic persistent organic pollutants (POPs) which have been identified in the aquatic and terrestrial environment including wildlife and humans. In exposed organisms including humans toxic effects, bioaccumulation, metabolism, and pharmacokinetics (especially half-life t{sub 1/2}) are important criterions in the hazard assessment. The aim of the present study was to estimate the terminal elimination half-lives (t{sub 1/2H}) of the main BFRs from the whole body (also named body-burden half-life) and/or from the adipose tissue (fat) of adult humans. The t{sub 1/2H} data for the following BFRs were evaluated: TBBPA, HBCD, 2,2',4,4'- tetrabromodiphenyl ether (BDE-47), 2,2',4,4',5-pentaBDE (BDE-99), 2,2',4,4',6-pentaBDE (BDE- 100), 2,2',4,4',5,5'-hexaBDE (BDE-153), and 2,2',4,4',5,6-hexaBDE (BDE-154).

  13. Half-life determination for 27Mg

    Science.gov (United States)

    Zahn, G. S.; Genezini, F. A.

    2015-07-01

    In this work, the half-life of the short-lived magnesium radionuclide 27Mg was measured by following the activity of samples after they were irradiated in the IEA-R1 reactor. An exponential decay function was then fitted to the results using the counts from a 60Co source as livetime chronometer; the individual half-life values obtained for each irradiation were compiled using both the usual unweighted and σ-2-weighted averages, as well as the robust averages obtained using the Normalized Residuals and the Rajeval techniques. The final halflive values obtained aren't compatible with the ENSDF compilation values, but have a similar uncertainty; analysis of the experimental literature values, all from the 50’s-60’s, show that further measurements should be undertaken in order to achieve a more robust consensus value for this half-life.

  14. Half-life of 51Mn

    Science.gov (United States)

    Graves, Stephen A.; Ellison, Paul A.; Valdovinos, Hector F.; Barnhart, Todd E.; Nickles, Robert J.; Engle, Jonathan W.

    2017-07-01

    The half-life of 51Mn was measured by serial gamma spectrometry of the 511-keV annihilation photon following decay by β+ emission. Data were collected every 100 seconds for 100,000-230,000 seconds within each measurement (n =4 ). The 511-keV incidence rate was calculated from the 511-keV spectral peak area and count duration, corrected for detector dead time and radioactive decay. Least-squares regression analysis was used to determine the half-life of 51Mn while accounting for the presence of background contaminants, notably 55Co. The result was 45.59 ±0.07 min, which is the highest precision measurement to date and disagrees with the current Nuclear Data Sheets value by over 6 σ .

  15. Half-life of samarium-147

    CERN Document Server

    Kinoshita, N; Nakanishi, T

    2003-01-01

    The alpha-decay half-life of sup 1 sup 4 sup 7 Sm has been reevaluated. Known amounts of natural Sm and an alpha-emitter standard ( sup 2 sup 1 sup 0 Po, sup 2 sup 3 sup 8 U, or sup 2 sup 4 sup 1 Am) were mixed well to prepare thin sources for the simultaneous counting of sup 1 sup 4 sup 7 Sm and the alpha-emitter standard by means of an alpha-spectrometer using a silicon surface barrier detector. The alpha-disintegration rate of known amounts of sup 1 sup 4 sup 7 Sm was determined by reference to the alpha activity of the standard. The source preparation and counting were repeated to establish the reproducibility of the present half-life determination, and supplementary alpha spectrometry was carried out by a liquid-scintillation spectrometer. The arithmetic mean of the experimental half-life values was obtained to be (1.17 +- 0.02) x 10 sup 1 sup 1 y. This value is about 10% longer than the currently adopted value, (1.06 +- 0.02) x 10 sup 1 sup 1 y, and the possible factors for this difference are discussed...

  16. The half-life of 125I

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.

    1989-01-01

    The Bureau International des Poids et Mesures (BIPM) organized an international comparison of activity measurements of a solution of 125 I. The half-life value adopted was 59.5±0.4d. The large uncertainty took account of a recently published value (Schrader, 1986) which is considerably lower than the widely used value of 60.0±0.1d. The present work, which was undertaken at the suggestion of the BIPM, has yielded a value which confirms the lower measurement. (author)

  17. Half-life of Xe120

    Science.gov (United States)

    Phillips, A. A.; Andreoiu, C.; Ball, G. C.; Bandyopadhyay, D.; Behr, J. A.; Chupp, T. E.; Finlay, P.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hayden, M. E.; Hyland, B.; Nuss-Warren, S. R.; Pearson, M. R.; Schumaker, M. A.; Smith, M. B.; Svensson, C. E.; Tardiff, E. R.; Valiente-Dobón, J. J.; Warner, T.

    2006-08-01

    We have measured the half-life of Xe120 using a high-purity germanium (HPGe) detector to monitor the 176, 178, and 762 keV γ rays from Xe120 β+ decay. The result, 46±0.6 min, differs significantly from the value 40±1 min reported by Andersson [Ark. Fys. 28, 37 (1964)]. We have also measured the half-lives of Cs120 and I120 to be 60±0.7 s and 82.1±0.6 min, respectively, both of which are consistent with previous measurements.

  18. Validation of effective half-life of tritium and computation of dose at Madras Atomic Power Station

    International Nuclear Information System (INIS)

    Moolya, L.L.; Kannan, R.K.; Sreekumaran Nair, B.; Mohandas, P.G.; Rajan, R.

    2001-01-01

    In Pressurised Heavy Water Reactors (PHWRs) tritium is produced by the activation of deuterium present in the moderator and coolant system. Hence, the inventory of tritium in PHWR is high and it contributes about 20 percent of the Station Dose. Tritium enters body by inhalation, ingestion and skin absorption. Dose received by an individual depends on its elimination rate from the body and hence the effective half-life. It is found that the effective half-life varies from person to person. The effective half-life also depends on the weather condition. The variation of effective half-life is taken care of in dose estimation by average method. However, in case of dose calculation for single uptake cases, there is a need to take fixed effective half-life. ICRP has taken the effective half-life as 10 days. The effective half-life is taken as 6 days in Indian conditions based on the studies conducted earlier in MAPS and elsewhere. Now with available data for about 16 years a fresh study was conducted to validate the effective half-life. This paper gives the study of effective half-life of tritium and its variation during different seasons of the year in MAPS. This paper also gives methods used for computing dose due to tritium. (author)

  19. Immunological half-life of porcine proinsulin C-peptide

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, H; Horino, M; Matsumura, S [Kawasaki Medical Coll., Kurashiki (Japan). Div. of Endocrinology; Kobayshi, K; Suetsugu, N [Yamaguchi Univ., Ube (Japan). School of Medicine

    1975-11-01

    Immunological half-lifes of injected porcine C-peptide and insulin with RIA were studied and calculated as 9.8 and 8.0 minutes. Higher circulating levels of C-peptide as compared to insulin in normal young swines lead to speculation about a longer half-life of C-peptide. This hypothesis was verified in this study. Immunological half-lifes of porcine proinsulin and insulin in the pig were 20 and 6 minutes, respectively.

  20. Intrinsically Disordered Segments Affect Protein Half-Life in the Cell and during Evolution

    Directory of Open Access Journals (Sweden)

    Robin van der Lee

    2014-09-01

    Full Text Available Precise control of protein turnover is essential for cellular homeostasis. The ubiquitin-proteasome system is well established as a major regulator of protein degradation, but an understanding of how inherent structural features influence the lifetimes of proteins is lacking. We report that yeast, mouse, and human proteins with terminal or internal intrinsically disordered segments have significantly shorter half-lives than proteins without these features. The lengths of the disordered segments that affect protein half-life are compatible with the structure of the proteasome. Divergence in terminal and internal disordered segments in yeast proteins originating from gene duplication leads to significantly altered half-life. Many paralogs that are affected by such changes participate in signaling, where altered protein half-life will directly impact cellular processes and function. Thus, natural variation in the length and position of disordered segments may affect protein half-life and could serve as an underappreciated source of genetic variation with important phenotypic consequences.

  1. Intrinsically disordered segments and the evolution of protein half-life

    Science.gov (United States)

    Babu, M.

    2013-03-01

    Precise turnover of proteins is essential for cellular homeostasis and is primarily mediated by the proteasome. Thus, a fundamental question is: What features make a protein an efficient substrate for degradation? Here I will present results that proteins with a long terminal disordered segment or internal disordered segments have a significantly shorter half-life in yeast. This relationship appears to be evolutionarily conserved in mouse and human. Furthermore, upon gene duplication, divergence in the length of terminal disorder or variation in the number of internal disordered segments results in significant alteration of the half-life of yeast paralogs. Many proteins that exhibit such changes participate in signaling, where altered protein half-life will likely influence their activity. We suggest that variation in the length and number of disordered segments could serve as a remarkably simple means to evolve protein half-life and may serve as an underappreciated source of genetic variation with important phenotypic consequences. MMB acknowledges the Medical Research Council for funding his research program.

  2. Experimental study of half-life determinations using 60Co

    International Nuclear Information System (INIS)

    Rutledge, A.R.; Smith, L.V.; Merritt, J.S.

    1983-01-01

    The half-life of 60 Co was determined by two methods, (i) the 4π#betta# ionization chamber method and (ii) the 4π #betta#-#betta# coincidence method. The first is a relative counting method in which the only rate-dependent correction is for background, whereas the second is an 'absolute' counting method which involves several rate-dependent corrections. In addition, various methods of calculation of the results were tested. The half-life values for the two counting systems were in good agreement and the weighted mean value for the half-life of 60 Co was found to be 1925.02+-0.47 d. (orig.)

  3. Dependence of radiocaesium biological half-life in freshwater fish on water potassium concentration and temperature

    International Nuclear Information System (INIS)

    Carreiro, M.C.V.; Corisco, J.A.G.

    1998-01-01

    Short-term experiments (35-49 days) showed that the rate of cesium elimination from fish increases with increasing potassium concentration in water (the biological half-life decreases); this, however, is only true of the potassium concentration range of 0.35 to 3.5 ppm, whereas higher potassium concentrations do not seem to affect the elimination rate. Decrease in water temperature within the 20 degC to 5 degC range slows down the cesium elimination process. (P.A.)

  4. A new determination of the 209Po half-life

    International Nuclear Information System (INIS)

    Collé, R; Fitzgerald, R P; Laureano–Perez, L

    2014-01-01

    A substantial 25% error in the then-known and accepted (102 ± 5) year half-life of 209 Po was reported on in 2007. This error was detected from decay data from two separate primary standardizations of a 209 Po solution standard, which were performed approximately 12 years apart. Despite author claims that this observation was not a new half-life determination, it was nevertheless included in subsequent nuclear data evaluations and compilations to obtain a currently tabulated value of (115 ± 13) a, computed from the median and range of the two half-life reports. A third primary standardization on the identical 209 Po solution has since been performed to derive a new half-life value of (125.2 ± 3.3) a. This half-life determination was obtained from 30 distinct data sets over a period of 20.7 years, encompassing over 700 liquid scintillation measurements with nearly 50 counting sources all prepared from the same solution, and as obtained over a very broad range of measurement conditions (composition of cocktails, characteristics of counters, time sequencing) during five periods in 1993, 1994, 2005, and 2013. (paper)

  5. Half-life of 90Sr - measurement and critical review

    International Nuclear Information System (INIS)

    Woods, M.J.; Lucas, S.E.M.

    1996-01-01

    Recent evaluations of the half-life of 90 Sr have demonstrated the variable quality of the available experimental data which has prevented the estimation and adoption of a value that commands confidence. In an attempt to reduce the uncertainty in the half-life to an acceptable level, the decay of a 90 Sr source has been followed for over six years at NPL. The equipment comprised matching, re-entrant, high-pressure ionization chambers and a long-lived reference source to reduce non-random effects. The experimental technique is described together with the statistical procedure used to analyse the measured data. A half-life value was determined together with an estimate of the associated uncertainties. A new evaluation of the 90 Sr half-life has been made, taking account of the new NPL data and other recent measurements. Particular attention has been paid to the experimental techniques used to produce the data and the uncertainties attributed to them. An objective evaluation has been conducted to produce a new recommended half-life value of 10 516 ± 21 days. (orig.)

  6. Determination of the {sup 151}Sm half-life

    Energy Technology Data Exchange (ETDEWEB)

    Be, Marie-Martine; Cassette, Philippe [CEA, LIST, Gif sur Yvette (France). LNE-Laboratoire National Henri Becquerel; Isnard, Helene [CEA-LANIE, Gif sur Yvette (France); and others

    2015-07-01

    New measurements have been undertaken to determine the half-life of {sup 151}Sm. A pure {sup 151}Sm solution was obtained after chemical separation from a samarium solution resulting from the dissolution of an irradiated samarium sample. The concentration of {sup 151}Sm in the solution was measured by mass spectrometry, combined with the isotope dilution technique. The activity of the solution was measured by liquid scintillation counting by six European laboratories as part of an international comparison. These combined results lead to a half-life of T{sub 1/2} = 94.6(6)a.

  7. Calculation of the biological half-life of radioactive isotopes

    International Nuclear Information System (INIS)

    Szabo, S.A.

    1982-01-01

    The biological half-life of 137 Cs and 90 Sr was determined based on K and Ca metabolism and on the considerable chemical similarity of K and Ca, carriers of Cs and Sr, resp. The tsub(1/2)=a/bxln2 formula was used for the calculation, where a is the quantity of the element in question, while b is the daily need of the animal for the given element. The biological half-life for cattle of both 137 Cs and 90 Sr was found to be 30 days, while that for swine 20 days and 35 days respectively. (Sz.J.)

  8. Measurement of the 20F half-life

    Science.gov (United States)

    Hughes, M.; George, E. A.; Naviliat-Cuncic, O.; Voytas, P. A.; Chandavar, S.; Gade, A.; Huyan, X.; Liddick, S. N.; Minamisono, K.; Paulauskas, S. V.; Weisshaar, D.

    2018-05-01

    The half-life of the 20F ground state was measured using a radioactive beam implanted in a plastic scintillator and recording β γ coincidences together with four CsI(Na) detectors. The result, T1 /2=11.0011 (69) stat(30) sys s, is at variance by 17 combined standard deviations with the two most precise results. The present value revives the poor consistency of results for this half-life and calls for a new measurement, with a technique having different sources of systematic effects, to clarify the discrepancy.

  9. Half-life distribution table of radioactive nuclei

    International Nuclear Information System (INIS)

    Gugenberger, P.

    1954-01-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [fr

  10. Determination of disintegration half-life of 252Cf

    International Nuclear Information System (INIS)

    Chen Keliang; Liu Guoxing; Wang Sufang; Zheng Jiwen

    1991-01-01

    The follow-up measurements have been made by using a Si(Au) detector with small solid angle geometry for α disintegration of 252 Cf. The measured half-life of disintegration is 2.638 ± 0.009 year. This value is in accordance with other previous results

  11. Experimental half-life determination of 176Lu

    International Nuclear Information System (INIS)

    Kossert, Karsten; Jörg, Gerhard; Gostomski, Christoph Lierse v.

    2013-01-01

    The half-life of the naturally occurring long-lived rare earth isotope 176 Lu was determined by a combination of highly sophisticated experimental procedures in order to further improve the reliability and the precision of literature data. The amount of lutetium in the samples was determined by inductively coupled plasma optical emission spectrometry (ICP-OES) using a NIST reference standard. The isotopic ratio N( 176 Lu)/N(Lu) in the samples was measured by means of inductively coupled plasma high resolution mass spectrometry (ICP-HRMS). The activity divided by the mass of Lu was determined by applying liquid scintillation (LS) counting. The LS counting efficiency of the beta/gamma emitter 176 Lu was determined with the CIEMAT/NIST efficiency tracing technique with low uncertainty. The influences of colour quenching and background effects are discussed in this paper. The half-life was found to be 3.640(35)×10 10 y. The result is in good agreement with other evaluations and the relative standard uncertainty of 0.95% is among the lowest of previously published data. - Highlights: • The half-life of 176 Lu was determined by ICP-OES, ICP-HRMS and LSC. • The LSC efficiency was determined with the CIEMAT/NIST method. • The half-life was found to be 3.640(35)×10 10 y

  12. Beyond effective half-life characterization of radionuclide dynamics

    International Nuclear Information System (INIS)

    Hermanska, J.; Blazek, T.; Karny, M.

    1996-01-01

    A refined model was set up and tested of the effective radionuclide half-life in nuclear medicine, making allowance for the fact that the basic assumption that the observed data can be fitted by a mono-exponential, as well as some other assumptions, is not true. The results are discussed. (P.A.). 1 tab., 32 refs

  13. Half-life of the superallowed β+ emitter Ne18

    Science.gov (United States)

    Grinyer, G. F.; Smith, M. B.; Andreoiu, C.; Andreyev, A. N.; Ball, G. C.; Bricault, P.; Chakrawarthy, R. S.; Daoud, J. J.; Finlay, P.; Garrett, P. E.; Hackman, G.; Hyland, B.; Leslie, J. R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Schumaker, M. A.; Svensson, C. E.; Valiente-Dobón, J. J.; Williams, S. J.; Zganjar, E. F.

    2007-08-01

    The half-life of Ne18 has been determined by detecting 1042-keV γ rays in the daughter F18 following the superallowed-Fermi β+ decay of samples implanted at the center of the 8πγ-ray spectrometer, a spherical array of 20 HPGe detectors. Radioactive Ne18 beams were produced on-line, mass-separated, and ionized using an electron-cyclotron-resonance ionization source at the ISAC facility at TRIUMF in Vancouver, Canada. This is the first high-precision half-life measurement of a superallowed Fermi β decay to utilize both a large-scale HPGe spectrometer and the isotope separation on-line technique. The half-life of Ne18, 1.6656 ± 0.0019 s, deduced following a 1.4σ correction for detector pulse pile-up, is four times more precise than the previous world average. As part of an investigation into potential systematic effects, the half-life of the heavier isotope Ne23 was determined to be 37.11 ± 0.06 s, a factor of 2 improvement over the previous precision.

  14. Measurement of the 8Li half-life

    International Nuclear Information System (INIS)

    Flechard, X.; Lienard, E.; Naviliat-Cuncic, O.; Ban, G.; Carniol, B.; Etasse, D.; Fontbonne, J. M.; Rodriguez, D.; Lallena, A. M.; Alvarez, M. A. G.; Praena, J.

    2010-01-01

    We report a new measurement of the 8 Li half-life using a plastic scintillator and an ultrafast waveform digitizing module. The result, T 1/2 =(838.40±0.36) ms, improves by a factor of 2.5 the most precise result obtained so far and is furthermore deduced with negligible corrections due to dead time.

  15. Radioactive source simulation for half-life experiment

    International Nuclear Information System (INIS)

    Wanitsuksombut, Warapon; Decthyothin, Chanti

    1999-01-01

    A simulation of radioactivity decay by using programmable light source with a few minutes half-life is suggested. A photodiode with digital meter label in cps is use instead of radiation detector. Both light source and photodiode are installed in a black box to avoid surrounding room light. The simulation set can also demonstrate Inverse Square Law experiment of radiation penetration. (author)

  16. Measurement of the 230U half-life

    International Nuclear Information System (INIS)

    Pommé, S.; Altzitzoglou, T.; Van Ammel, R.; Suliman, G.; Marouli, M.; Jobbágy, V.; Paepen, J.; Stroh, H.; Apostolidis, C.; Abbas, K.; Morgenstern, A.

    2012-01-01

    The 230 U half-life was determined by measuring the decay curve of 230 U sources by various nuclear detection techniques: α-particle counting at a defined small solid angle; 4πα+β counting with a windowless CsI sandwich spectrometer, a liquid scintillation counter and a pressurised proportional counter; gamma-ray spectrometry with a HPGe detector and nearly-2π α-particle counting with an ion-implanted silicon detector. Depending on the technique, the decay was followed for 100–200 d, which is 5–10 times the 230 U half-life. The measurement results of the various techniques were in good mutual agreement. The mean value, T 1/2 ( 230 U)=20.23 (2) d, is lower than the literature value which is based on one measurement in 1948 and resulted in a half-life value of 20.8 d without statement of uncertainty. A correction for the ingrowth of the long-lived 210 Pb and its daughter products may have been overlooked in the past. - Highlights: ► Half-life of 230 U determined by various nuclear detection techniques. ► Result T 1/2 ( 230 U)=20.23 (2) d is lower than the literature value. ► 230 U/ 226 Th decay series has potential use in alpha-immunotherapy.

  17. Measurement of the half-life of 68Ga

    International Nuclear Information System (INIS)

    García-Toraño, Eduardo; Peyrés Medina, Virginia; Romero, Eduardo; Roteta, Miguel

    2014-01-01

    The half-life of the positron-emitter 68 Ga has been measured by following the decay rate with two systems based on ionization chamber and Ge detectors. The decay rate was measured for periods of time up to 10 half-lives. The combination of the 6 results obtained with both systems gives a value of T 1/2 =67.845(18) min, in good agreement with recommended data and with an uncertainty lower than any other previously reported value. - Highlights: • The half-life of the positron-emitter radionuclide 68 Ga was measured. • Two measurement setups (ionization chamber and Ge detector) were used. • Results agree with evaluated data but exhibit lower uncertainty

  18. Superior serum half life of albumin tagged TNF ligands

    International Nuclear Information System (INIS)

    Mueller, Nicole; Schneider, Britta; Pfizenmaier, Klaus; Wajant, Harald

    2010-01-01

    Due to their immune stimulating and apoptosis inducing properties, ligands of the TNF family attract increasing interest as therapeutic proteins. A general limitation of in vivo applications of recombinant soluble TNF ligands is their notoriously rapid clearance from circulation. To improve the serum half life of the TNF family members TNF, TWEAK and TRAIL, we genetically fused soluble variants of these molecules to human serum albumin (HSA). The serum albumin-TNF ligand fusion proteins were found to be of similar bioactivity as the corresponding HSA-less counterparts. Upon intravenous injection (i.v.), serum half life of HSA-TNF ligand fusion proteins, as determined by ELISA, was around 15 h as compared to approximately 1 h for all of the recombinant control TNF ligands without HSA domain. Moreover, serum samples collected 6 or 24 h after i.v. injection still contained high TNF ligand bioactivity, demonstrating that there is only limited degradation/inactivation of circulating HSA-TNF ligand fusion proteins in vivo. In a xenotransplantation model, significantly less of the HSA-TRAIL fusion protein compared to the respective control TRAIL protein was required to achieve inhibition of tumor growth indicating that the increased half life of HSA-TNF ligand fusion proteins translates into better therapeutic action in vivo. In conclusion, our data suggest that genetic fusion to serum albumin is a powerful and generally applicable mean to improve bioavailability and in vivo activity of TNF ligands.

  19. Half-life predictions for decay modes of superheavy nuclei

    International Nuclear Information System (INIS)

    Duarte, S.B.; Tavares, O.A.P.; Goncalves, M.; Rodriguez, O.; Guzman, F.; Barbosa, T.N.; Garcia, F.; Dimarco, A.

    2004-09-01

    We applied the Effective Liquid Drop Model (ELDM) to predict the alpha-decay, cluster emission and cold fission half-life-values of nuclei in the region of Superheavy Elements (SHE). The present calculations have been made in the region of the ZN-plane defined by 155 <=N <=220 and 110<=Z<=135. Shell effects are included via the Q-value of the corresponding decay case. We report the results of a systematic calculation of the half-life for the three nuclear decay modes in a region of the ZN-plane where superheavy elements are expected to be found. Results have shown that, among the decay modes investigated here, the alpha decay is the dominant one. i.e, the decay mode of smallest half-lives. Half-life predictions for alpha decay, cluster emission and cold fission for the isotopic family of the most recent SHE detected of Z=115 and for the isotopic family of the already consolidated SHE of Z=111 are presented. (author)

  20. Beryllium-10: Half-life and AMS-standards

    International Nuclear Information System (INIS)

    Hofmann, H.J.; Beer, J.; Bonani, G.; von Gunten, H.R.; Raman, S.; Suter, M.; Walker, R.L.; Woelfli, W.; Zimmermann, D.

    1987-01-01

    Absolute AMS measurements of 10 Be require reliable standards for calibration. Among the existing standards, rather large differences have been observed. These differences were found partially to be due to the different half-life values which were assumed. Also for comparison of AMS data with activity measurements, it is necessary to know the 10 Be half-life as precisely as possible. Starting with 5 ml of the standardized ORNL-MASTER solution, a working solution with a well-defined 10 Be content was prepared. Its specific activity was determined by liquid scintillation counting. This measurement yielded a new value of (1.52 +- 0.05) My for the 10 Be half-life, which is in agreement with the previously reported values but is about three times more accurate. Two independent dilution series produced new AMS standards with 10 Be/ 9 Be ratios of the order of 10 -10 and 10 -11 . These standards were measured at the ETH/SIN AMS facility with high accuracy and are compared with other available 10 Be standards. 15 refs, 2 figs., 3 tabs

  1. Examination of the biological half-life and organ d;stribution of tritiated lysin-vasopressin in Brattleboro rats

    International Nuclear Information System (INIS)

    Laczi, F.; Laszlo, F.

    1980-01-01

    15 μCi tritiated lysin-vasopressin (spec. act. 3.5 Ci per mmol) was administered to control and Brattleboro rats, suffering from hereditary hypothalamic diabetes insipidus. The biological half-life and the distribution of the labelled compound in the different organs were determined. The biological half-life demonstrated no significant difference, however, the vasopressin content of the small intestine was higher in the Brattleboro rats. In the other organs no significant difference was found. It can be concluded that the hereditary diabetes insipidus is not due to faster elimination of circulating vasopressin. (L.E.)

  2. Examination of the biological half-life and organ d; stribution of tritiated lysin-vasopressin in Brattleboro rats

    Energy Technology Data Exchange (ETDEWEB)

    Laczi, F; Laszlo, F [Szegedi Orvostudomanyi Egyetem Szeged (Hungary). 1. Belgyogyaszati Klinika; Keri, Gy; Teplan, I [Semmelweis Orvostudomanyi Egyetem, Budapest (Hungary)

    1980-04-01

    15 ..mu..Ci tritiated lysin-vasopressin (spec. act. 3.5 Ci per mmol) was administered to control and Brattleboro rats, suffering from hereditary hypothalamic diabetes insipidus. The biological half-life and the distribution of the labelled compound in the different organs were determined. The biological half-life demonstrated no significant difference, however, the vasopressin content of the small intestine was higher in the Brattleboro rats. In the other organs no significant difference was found. It can be concluded that the hereditary diabetes insipidus is not due to faster elimination of circulating vasopressin.

  3. Precision half-life measurement of 17F

    Science.gov (United States)

    Brodeur, M.; Nicoloff, C.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Gupta, Y. K.; Hall, M. R.; Hall, O.; Hu, J.; Kelly, J. M.; Kolata, J. J.; Long, J.; O'Malley, P.; Schultz, B. E.

    2016-02-01

    Background: The precise determination of f t values for superallowed mixed transitions between mirror nuclide are gaining attention as they could provide an avenue to test the theoretical corrections used to extract the Vu d matrix element from superallowed pure Fermi transitions. The 17F decay is particularly interesting as it proceeds completely to the ground state of 17O, removing the need for branching ratio measurements. The dominant uncertainty on the f t value of the 17F mirror transition stems from a number of conflicting half-life measurements. Purpose: A precision half-life measurement of 17F was performed and compared to previous results. Methods: The life-time was determined from the β counting of implanted 17F on a Ta foil that was removed from the beam for counting. The 17F beam was produced by transfers reaction and separated by the TwinSol facility of the Nuclear Science Laboratory of the University of Notre Dame. Results: The measured value of t1/2 new=64.402 (42) s is in agreement with several past measurements and represents one of the most precise measurements to date. In anticipation of future measurements of the correlation parameters for the decay and using the new world average t1/2 world=64.398 (61) s, we present a new estimate of the mixing ratio ρ for the mixed transition as well as the correlation parameters based on assuming Standard Model validity. Conclusions: The relative uncertainty on the new world average for the half-life is dominated by the large χ2=31 of the existing measurements. More precision measurements with different systematics are needed to remedy to the situation.

  4. Thyroid fractional deposition and half life of radioiodine

    International Nuclear Information System (INIS)

    Fujita, Minoru

    1974-01-01

    In order to measure the absorbed dose of radioiodine in the thyroid gland, which was incorporated by halation or ingestion, iodine intake (fa), 131 I thyroid uptake rate(fw), 131 I thyroid uptake rate compared to the rate in the whole body (f 2 ) and the half life of iodine in the thyroid gland(Teff) were examined. Thyroid fractional deposition of 131 I was compared between Japanese and European. The rate of 131 I which moved from the blood into the thyroid gland in children (f 2 ') and the effect of the iodine in meals on 131 I thyroid uptake (fw) were also studied. In Japanese, f 2 was 0.28 and the mean Teff was 6.9 +- 0.7 days in 11 Japanese adults. There was an individual difference in these biological parameter and the values in adults were different from those in children. A little difference in value between Japanese and European suggested to be caused by the greater amount of stable iodine in meals in Japanese. (Serizawa, K.)

  5. A formula for half-life of proton radioactivity

    Science.gov (United States)

    Zhang, Zhi-Xing; Dong, Jian-Min

    2018-01-01

    We present a formula for proton radioactivity half-lives of spherical proton emitters with the inclusion of the spectroscopic factor. The coefficients in the formula are calibrated with the available experimental data. As an input to calculate the half-life, the spectroscopic factor that characterizes the important information on nuclear structure should be obtained with a nuclear many-body approach. This formula is found to work quite well, and in better agreement with experimental measurements than other theoretical models. Therefore, it can be used as a powerful tool in the investigation of proton emission, in particular for experimentalists. Supported by National Natural Science Foundation of China (11435014, 11405223, 11675265, 11575112), the 973 Program of China (2013CB834401, 2013CB834405), National Key Program for S&T Research and Development (2016YFA0400501), the Knowledge Innovation Project (KJCX2-EW-N01) of Chinese Academy of Sciences, the Funds for Creative Research Groups of China (11321064) and the Youth Innovation Promotion Association of Chinese Academy of Sciences

  6. Influence of renal function on the elimination of morphine and morphine glucuronides

    DEFF Research Database (Denmark)

    Wolff, Jesper; Bigler, Dennis Richard; Christensen, C B

    1988-01-01

    plasma. No significant correlation was found between total body clearance of unconjugated morphine and 51Cr-EDTA clearance. However, patients with renal insufficiency had impaired elimination of morphine glucuronides, and the apparent clearance was significantly correlated with the 51Cr-EDTA clearance (r...... = 0.94, p less than 0.001). A relatively long terminal elimination of half-life of morphine was found in all patients (mean +/- SD: 9.2 +/- 2.5 h), irrespective of glomerular function....

  7. High-precision half-life measurements of the T =1 /2 mirror β decays 17F and 33Cl

    Science.gov (United States)

    Grinyer, J.; Grinyer, G. F.; Babo, M.; Bouzomita, H.; Chauveau, P.; Delahaye, P.; Dubois, M.; Frigot, R.; Jardin, P.; Leboucher, C.; Maunoury, L.; Seiffert, C.; Thomas, J. C.; Traykov, E.

    2015-10-01

    Background: Measurements of the f t values for T =1 /2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the f t values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T =1 /2 β+ emitters, 17F and 33Cl, in order to eliminate the half-life as the leading source of uncertainty in their f t values. Method: Half-lives of 17F and 33Cl were determined using β counting of implanted radioactive ion beam samples on a moving tape transport system at the Système de Production d'Ions Radioactifs Accélérés en Ligne low-energy identification station at the Grand Accélérateur National d'Ions Lourds. Results: The 17F half-life result, 64.347 (35) s, precise to ±0.05 % , is a factor of 5 times more precise than the previous world average. The half-life of 33Cl was determined to be 2.5038 (22) s. The current precision of ±0.09 % is nearly 2 times more precise compared to the previous world average. Conclusions: The precision achieved during the present measurements implies that the half-life no longer dominates the uncertainty of the f t values for both T =1 /2 mirror decays 17F and 33Cl.

  8. Comparison of isotope dilution and excretion methods for determining the half-life of ascorbic acid in the guinea pig

    International Nuclear Information System (INIS)

    Kipp, D.E.; Rivers, J.M.

    1984-01-01

    The half-life of ascorbic acid (AA) in guinea pigs was investigated by the isotope dilution and excretion methods. The dilution method measures [1-14C]AA disappearance from the plasma, whereas the excretion method measures the elimination of [1-14C]AA and the metabolites from the body. Two groups of animals underwent both isotope studies in reverse order. Animals were conditioned to the experimental procedures and fed 2.5 mg AA/100 g body weight orally to maintain a daily intake of the vitamin independent of food consumption. The two isotope procedures imposed similar stress on the animals, as determined by plasma cortisol levels and body weight changes. The AA half-life calculations of the rapidly exchangeable pool by the isotope dilution method yielded values of 1.23 and 0.34 hours for the two groups, respectively. The half-life of the slowly exchangeable pool for the two groups was 60.2 and 65.8 hours, respectively. The half-life of AA in the rapidly exchangeable pool, as measured by the excretion studies, was 4.57-8.75 hours. For the slowly exchangeable pool, it was 146-149 hours. The longer half-life of both pools obtained with the excretion method indicates that the isotope is disappearing from the plasma more rapidly than it is being excreted. This suggests that a portion of the [1-14C]AA leaving the plasma is removed to a body pool that is not sampled by the isotope excretion method

  9. Study on the biological half-life and organ-distribution of tritiated lysine-vasopressin in Brattleboro rats

    International Nuclear Information System (INIS)

    Laczi, F.; Laszlo, F.A.; Keri, Gy.; Teplan, I.

    1980-01-01

    The biological half-life and organ-distribution of tritiated lysine-vasopressin were determined in R-Amsterdam rats, and in homozygous and heterozygous Brattleboro rats with hereditary central diabetes insipidus. It was found that the biological half-life of the tritiated lysin-vasopressin in the Brattleboro rats did not differ significantly from that found in the R-Amsterdam rats. The highest radioactivities were observed in the neuro- and adenohypophyses and in the kidneys of both the R-Amsterdam and the Brattleboro rats. The accumulation of tritiated LVP was higher in the small intestine of the Brattleboro rats than in that of the R-Amsterdam animals. The results have led to the conclusion that the accelerated elimination of vasopressin and its pathologic organ-accumulation are probably not involved in the water metabolism disturbance of Brattleboro rats with hereditary hypothalamic diabetes insipidus. (author)

  10. Alkyne- and 1,6-elimination- succinimidyl carbonate – terminated heterobifunctional poly(ethylene glycol) for reversible "Click" PEGylation

    OpenAIRE

    Xie, Yumei; Duan, Shaofeng; Forrest, M. Laird

    2010-01-01

    A new heterobifunctional (succinimidyl carbonate, SC)-activated poly(ethylene glycol) (PEG) with a reversible 1,6-elimination linker and a terminal alkyne for "click" chemistry was synthesized with high efficiency and low polydispersity. The α-alkyne-ω-hydroxyl PEG was first prepared using trimethylsilyl-2-propargyl alcohol as an initiator for ring-opening polymerization of ethylene oxide followed by mild deprotection with tetrabutylammonium fluoride. The hydroxy end was then modified with di...

  11. Precise half-life measurement of the superallowed emitter 30S

    Science.gov (United States)

    Iacob, V. E.; Hardy, J. C.; Chen, L.; Horvat, V.; Bencomo, M.; Nica, N.; Park, H. I.; Roeder, B. T.; Saastamoinen, A.

    2018-03-01

    We have measured the half-life of 30S, the parent of a superallowed 0+→0+β transition, to a high precision using very pure sources and a 4 π proportional gas counter to detect the decay positrons. Our result for the half-life is 1.179 92(34) s. As a by-product of this measurement, we determine the half-life of its daughter, 30P, to be 2.501(2) min.

  12. On the 209Po half-life error and its confirmation. A critique

    International Nuclear Information System (INIS)

    Colle, R.; Colle, A.M.

    2016-01-01

    A recent report on 209 Po claimed to have made a determination of the 125-a half-life from measurements made over 0.8 % of one half-life. A careful reanalysis of the original data with a more complete and rigorous consideration of the underlying uncertainties demonstrates that this claim cannot withstand critical scrutiny. More importantly, this critique examines the larger issue as to what constitutes a valid half-life determination, and highlights that a careful and realistic analysis beyond the mere fitting of decay data to an exponential function is required for the measurement and reporting of half-life values. (author)

  13. The Use of Gene Ontology Term and KEGG Pathway Enrichment for Analysis of Drug Half-Life.

    Directory of Open Access Journals (Sweden)

    Yu-Hang Zhang

    Full Text Available A drug's biological half-life is defined as the time required for the human body to metabolize or eliminate 50% of the initial drug dosage. Correctly measuring the half-life of a given drug is helpful for the safe and accurate usage of the drug. In this study, we investigated which gene ontology (GO terms and biological pathways were highly related to the determination of drug half-life. The investigated drugs, with known half-lives, were analyzed based on their enrichment scores for associated GO terms and KEGG pathways. These scores indicate which GO terms or KEGG pathways the drug targets. The feature selection method, minimum redundancy maximum relevance, was used to analyze these GO terms and KEGG pathways and to identify important GO terms and pathways, such as sodium-independent organic anion transmembrane transporter activity (GO:0015347, monoamine transmembrane transporter activity (GO:0008504, negative regulation of synaptic transmission (GO:0050805, neuroactive ligand-receptor interaction (hsa04080, serotonergic synapse (hsa04726, and linoleic acid metabolism (hsa00591, among others. This analysis confirmed our results and may show evidence for a new method in studying drug half-lives and building effective computational methods for the prediction of drug half-lives.

  14. High-precision half-life measurements of the T=1/2 mirror beta decays F-17 and Cl-33

    OpenAIRE

    Grinyer, J; Grinyer, G. F; Babo, Mathieu; Bouzomita, H; Chauveau, P; Delahaye, P; Dubois, M; Frigot, R; Jardin, P; Leboucher, C; Maunoury, L; Seiffert, C; Thomas, J. C; Traykov, E

    2015-01-01

    Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, 17F and 33Cl, in order to eliminate the half-life as th...

  15. High-precision half-life measurements of the T=1/2 mirror β decays F17 and Cl33

    OpenAIRE

    Grinyer, J; Grinyer, G F; Babo, M; Bouzomita, H; Chauveau, P; Delahaye, P; Dubois, M; Frigot, R; Jardin, P; Leboucher, C; Maunoury, L; Seiffert, C; Thomas, J C; Traykov, E

    2015-01-01

    Background: Measurements of the ft values for T=1/2 mirror β+ decays offer a method to test the conserved vector current hypothesis and to determine Vud, the up-down matrix element of the Cabibbo-Kobayashi-Maskawa matrix. In most mirror decays used for these tests, uncertainties in the ft values are dominated by the uncertainties in the half-lives. Purpose: Two precision half-life measurements were performed for the T=1/2β+ emitters, F17 and Cl33, in order to eliminate the half-life as the le...

  16. The ecological half-life of 137Cs in undisturbed silt soil

    International Nuclear Information System (INIS)

    Drosg, M.

    2012-01-01

    The time necessary to safely cultivate agricultural areas after they have been contaminated by radioactivity (e.g. after the Chernobyl accident) is not determined by the physical half-life of the radioactive isotopes in question but by their (usually much shorter) ecological half-life (). This half-life not only depends on the type of soil but also on whether the soil was fertilized or not. Therefore it is not possible to determine an ecological half-life that is universally valid. However, the value for undisturbed, unfertilized soil should provide a general indication for the duration of ecological half-life. In a silt soil in Vienna, Austria, the ecological half-life of 137 Cs was determined to be 0.8 years, which is much shorter than the physical half-life of 30 years. - Highlights: ► Absolute measurements of 137 Cs radioactivity in leaves of perennial plants. ► The natural 40 K radioactivity served as reference. ► The ecological half-life of 137 Cs in loamy soil was determined.

  17. Fusion to Human Serum Albumin Extends the Circulatory Half-Life and Duration of Antithrombotic Action of the Kunitz Protease Inhibitor Domain of Protease Nexin 2.

    Science.gov (United States)

    Sheffield, William P; Eltringham-Smith, Louise J; Bhakta, Varsha

    2018-01-01

    The Kunitz Protease Inhibitor (KPI) domain of protease nexin 2 (PN2) potently inhibits coagulation factor XIa. Recombinant KPI has been shown to inhibit thrombosis in mouse models, but its clearance from the murine circulation remains uncharacterized. The present study explored the pharmacokinetic and pharmacodynamic effects of fusing KPI to human serum albumin (HSA) in fusion protein KPIHSA. Hexahistidine-tagged KPI (63 amino acids) and KPIHSA (656 amino acids) were expressed in Pichia pastoris yeast and purified by nickel-chelate chromatography. Clearance profiles in mice were determined, as well as the effects of KPI or KPIHSA administration on FeCl3-induced vena cava thrombus size or carotid artery time to occlusion, respectively. Fusion to HSA increased the mean terminal half-life of KPI by 8-fold and eliminated its interaction with the low density lipoprotein receptor-related protein. KPI and KPIHSA similarly reduced thrombus size and occlusion in both venous and arterial thrombosis models when administered at the time of injury, but only KPI was effective when administered one hour before injury. Albumin fusion deflects KPI from rapid in vivo clearance without impairing its antithrombotic properties and widens its potential therapeutic window. © 2018 The Author(s). Published by S. Karger AG, Basel.

  18. The half-life of 227Th by direct and indirect measurements

    International Nuclear Information System (INIS)

    Collins, S.M.; Pommé, S.; Jerome, S.M.; Ferreira, K.M.; Regan, P.H.; Pearce, A.K.

    2015-01-01

    Utilising a chemically purified solution the radioactive half-life of 227 Th has been determined indirectly by observation of the ingrowth of 223 Ra using an ionisation chamber (IC) and for the first time by direct observation of the change in activity with time using a high-purity germanium (HPGe) γ-ray spectrometer. The radioactive decay was observed for ~104 days (~5.6 half-lives) by γ-ray spectrometry and approximately 63 days and 72 days (~3.4 and ~3.9 half-lives) using an ionisation chamber (IC). The resulting half-life values – 18.695 (4) days (IC) and 18.683 (20) days (HPGe) – are consistent and detailed uncertainty budgets are presented for the two measurement techniques. A weighted mean of our results of 18.695 (4) days is inconsistent with the most precise published half-life value of 18.7176 (52) days (Jordan and Blanke, 1967). A critical evaluation of literature data has been performed, indicating a paucity of reliable and independent measurements. Selected independent published values have been used to determine a recommended half-life of 18.697 (7) days. A method has been introduced in the course of this work so that the recommended half-life of 227 Th as determined by ingrowth can be modified if a different 223 Ra half-life has been determined, evaluated and adopted. - Highlights: • First direct measurement of 227 Th half-life by HPGe γ-ray spectrometry. • Precision half-life measurement by ionisation chamber. • New half-life of 18.695 (4) days determined. • Critical evaluation of published half-lives and recommended value determined

  19. Half-life evaluations for 3H, 90Sr, and 90Y

    International Nuclear Information System (INIS)

    MacMahon, Desmond

    2006-01-01

    A recent paper has reviewed methods for the evaluation of discrepant sets of data and demonstrated the results of applying these methods to the published half-life data of 90 Sr and 137 Cs [MacMahon, T.D., Pearce, A., Harris, P., 2004. Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281]. The half-life data for 3 H has been subject to a comprehensive review and critical evaluation by Lucas and Unterweger [2000. Comprehensive review and critical evaluation of the half-life of tritium. J. Res. Natl. Inst. Stand. Technol. 105, 541-549]. The current paper reports the results of applying the various evaluation procedures of MacMahon et al. Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281] to the data of Lucas and Unterweger [Comprehensive review and critical evaluation of the half-life of tritium. J. Res. Natl. Inst. Stand. Technol. 105, 541-549], resulting in a recommended half-life of 4497(4) days. MacMahon et al. [Convergence of techniques for the evaluation of discrepant data. Appl. Radiat. Isot. 60, 275-281] highlighted problems in the evaluation of the discrepant half-life data of 90 Sr, in particular the worrying upward trend in the data, where the weighted mean of all the measurements increases, on average, by 35 days each time a new measurement result is added. The current paper reports on further analyses of these data. New measurements of the half-life of 90 Y have been reported by Kossert and Schrader [2004. Standardization by liquid scintillation counting and half-life measurements of 90 Y. Appl. Radiat. Isot. 60, 741]. This has prompted a new evaluation of all available published 90 Y half-life data. The data are fairly consistent, and a value of 64.063(16) h is recommended

  20. Alkyne- and 1,6-elimination- succinimidyl carbonate - terminated heterobifunctional poly(ethylene glycol) for reversible "Click" PEGylation.

    Science.gov (United States)

    Xie, Yumei; Duan, Shaofeng; Forrest, M Laird

    2010-01-01

    A new heterobifunctional (succinimidyl carbonate, SC)-activated poly(ethylene glycol) (PEG) with a reversible 1,6-elimination linker and a terminal alkyne for "click" chemistry was synthesized with high efficiency and low polydispersity. The α-alkyne-ω-hydroxyl PEG was first prepared using trimethylsilyl-2-propargyl alcohol as an initiator for ring-opening polymerization of ethylene oxide followed by mild deprotection with tetrabutylammonium fluoride. The hydroxy end was then modified with diglycolic anhydride to generate α-alkyne-ω-carboxylic acid PEG. The reversible 1, 6-elimination linker was introduced by conjugation of a hydroxymethyl phenol followed by activation with N,N'-disuccinimidyl carbonate to generate the heterobifunctional α-alkyne-ω-SC PEG. The terminal alkyne is available for "click" conjugation to azido ligands via 1,3-dipolar cycloaddition, and the succinimidyl carbonate will form a reversible conjugate to amines (e.g. in proteins) that can release the unaltered amine after base or enzyme catalyzed cleavage of the 1,6-linker.

  1. Update of NIST half-life results corrected for ionization chamber source-holder instability.

    Science.gov (United States)

    Unterweger, M P; Fitzgerald, R

    2014-05-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. © 2013 Published by Elsevier Ltd.

  2. Update of NIST half-life results corrected for ionization chamber source-holder instability

    International Nuclear Information System (INIS)

    Unterweger, M.P.; Fitzgerald, R.

    2014-01-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. - Highlights: • The NIST half-life data is corrected for sample positioning variations and refitted. • These results are reported and increased errors in the reported values are given. • Longer lived radionuclides are discussed

  3. Influence of sex and age on the biological half-life of cadmium in mice

    International Nuclear Information System (INIS)

    Taguchi, T.; Suzuki, S.

    1981-01-01

    The influence of age on the whole-body biological half-life of 109 Cd was studied in male mice following ip injection. The influence of sex on whole-body and organ retention was ascertained after sc injection. The whole-body biological half-life of 109 Cd of the older mice was more than twice that of the younger mice, and that of the female mice was longer than that of the males. These differences demonstrate a biological difference between males and females with respect to whole-body half-life of 109 Cd. The effects of age and sex on the biological half-life of Cd in mice are assessed quantitatively

  4. The HP 9825 A program for the determination of an isotope half-life

    International Nuclear Information System (INIS)

    Jujuratisbela, Uju.

    1980-01-01

    Determination of half life of gold 198, indium 116, manganese 56, copper 64 are presented, using least squares method in HP 9825 A. This method is more accurate and needs less time than graphic method. (author tr.)

  5. Designing of peptides with desired half-life in intestine-like environment

    KAUST Repository

    Sharma, Arun; Singla, Deepak; Rashid, Mamoon; Raghava, Gajendra Pal Singh

    2014-01-01

    hindered mainly because of their high susceptibility towards proteases degradation. We have developed an in silico method to predict the half-life of peptides in intestine-like environment and to design better peptides having optimized physicochemical

  6. Fast renal trapping of porcine Luteinizing Hormone (pLH shown by 123I-scintigraphic imaging in rats explains its short circulatory half-life

    Directory of Open Access Journals (Sweden)

    Locatelli Alain

    2003-10-01

    Full Text Available Abstract Background Sugar moieties of gonadotropins play no primary role in receptor binding but they strongly affect their circulatory half-life and consequently their in vivo biopotencies. In order to relate more precisely hepatic trapping of these glycoproteic hormones with their circulatory half-life, we undertook a comparative study of the distribution and elimination of porcine LH (pLH and equine CG (eCG which exhibit respectively a short and a long half-life. This was done first by following half-lives of pLH in piglets with hepatic portal circulation shunted or not. It was expected that such a shunt would enhance the short half-life of pLH. Subsequently, scintigraphic imaging of both 123I-pLH and 123I-eCG was performed in intact rats to compare their routes and rates of distribution and elimination. Methods Native pLH or eCG was injected to normal piglets and pLH was tested in liver-shunted anæsthetized piglet. Blood samples were recovered sequentially over one hour time and the hormone concentrations were determined by a specific ELISA method. Scintigraphic imaging of 123I-pLH and 123I-eCG was performed in rats using a OPTI-CGR gamma camera. Results In liver-shunted piglets, the half-life of pLH was found to be as short as in intact piglets (5 min. In the rat, the half-life of pLH was also found to be very short (3–6 min and 123I-pLH was found to accumulate in high quantity in less than 10 min post injection at the level of kidneys but not in the liver. 123I-eCG didn't accumulate in any organ in the rats during the first hour, plasma concentrations of this gonadotropin being still elevated (80% at this time. Conclusion In both the porcine and rat species, the liver is not responsible for the rapid elimination of pLH from the circulation compared to eCG. Our scintigraphic experiments suggest that the very short circulatory half-life of LH is due to rapid renal trapping.

  7. Standardization of 40 K by liquid scintillation counting. Determination of the half-life

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1997-01-01

    The relative abundance of the natural radioisotope ''40 K in environmental samples frequently generates interferences in low activity measurements. In the present study we propose the determination of ''40 K by the CIEMAT/NIST method. On this context, the verification of ''40 K half-life is required. We present a half-life value obtained by liquid scintillation counting in excellent agreement with those reported in the literature. (Author)

  8. ESOL facility for the generation and radiochemical separation of short half-life fission products

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Meikrantz, D.H.; Baker, J.D.; Anderl, R.A.; Novick, V.J.; Greenwood, R.C.

    1988-01-01

    A facility has been developed at the Idaho National Engineering Laboratory (INEL) for the generation and rapid radiochemical separation of short half-life mixed fission products. This facility, referred to as the Idaho Elemental Separation On Line (ESOL), consists of electro-plated sources of spontaneously fissioning 252 Cf with a helium jet transport arrangement to continuously deliver short half-life, mixed fission products to the radiochemistry laboratory for rapid, computer controlled, radiochemical separations. 18 refs., 13 figs

  9. Using gamma distribution to determine half-life of rotenone, applied in freshwater

    Energy Technology Data Exchange (ETDEWEB)

    Rohan, Maheswaran, E-mail: mrohan@aut.ac.nz [Department of Biostatistics and Epidemiology, Auckland University of Technology, Auckland (New Zealand); Fairweather, Alastair; Grainger, Natasha [Science and Capability, Department of Conservation, Hamilton (New Zealand)

    2015-09-15

    Following the use of rotenone to eradicate invasive pest fish, a dynamic first-order kinetic model is usually used to determine the half-life and rate at which rotenone dissipated from the treated waterbody. In this study, we investigate the use of a stochastic gamma model for determining the half-life and rate at which rotenone dissipates from waterbodies. The first-order kinetic and gamma models produced similar values for the half-life (4.45 days and 5.33 days respectively) and days to complete dissipation (51.2 days and 52.48 days respectively). However, the gamma model fitted the data better and was more flexible than the first-order kinetic model, allowing us to use covariates and to predict a possible range for the half-life of rotenone. These benefits are particularly important when examining the influence that different environmental factors have on rotenone dissipation and when trying to predict the rate at which rotenone will dissipate during future operations. We therefore recommend that in future the gamma distribution model is used when calculating the half-life of rotenone in preference to the dynamic first-order kinetics model. - Highlights: • We investigated the use of the gamma model to calculate the half-life of rotenone. • Physical and environmental variables can be incorporated into the model. • A method for calculating the range around a mean half-life is presented. • The model is more flexible than the traditionally used first-order kinetic model.

  10. Variation in absorption and half-life of hydrocortisone influence plasma cortisol concentrations.

    Science.gov (United States)

    Hindmarsh, Peter C; Charmandari, Evangelia

    2015-04-01

    Hydrocortisone therapy should be individualized in congenital adrenal hyperplasia (CAH) patients to avoid over and under replacement. We have assessed how differences in absorption and half-life of cortisol influence glucocorticoid exposure. Forty-eight patients (21 M) aged between 6·1 and 20·3 years with CAH due to CYP21A2 deficiency were studied. Each patient underwent a 24-h plasma cortisol profile with the morning dose used to calculate absorption parameters along with an intravenous (IV) hydrocortisone (15 mg/m(2) body surface area) bolus assessment of half-life. Parameters derived were maximum plasma concentration (Cmax ), time of maximum plasma concentration (tmax ), time to attaining plasma cortisol concentration cortisol. Mean half-life was 76·5 ± 5·2 (range 40-225·3) min, Cmax 780·7 ± 61·6 nmol/l and tmax 66·7 (range 20-118) min. Time taken to a plasma cortisol concentration less than 100 nmol/l was 289 (range 140-540) min. Those with a fast half-life and slow tmax took longest to reach a plasma cortisol concentration less than 100 nmol/l (380 ± 34·6 min), compared to those with a slow half-life and fast tmax (298 ± 34·8 min) and those with a fast half-life and fast tmax (249·5 ± 14·4 min) (One-way anovaF = 4·52; P = 0·009). Both rate of absorption and half-life of cortisol in the circulation play important roles in determining overall exposure to oral glucocorticoid. Dose regimens need to incorporate estimates of these parameters into determining the optimum dosing schedule for individuals. © 2014 John Wiley & Sons Ltd.

  11. Designing of peptides with desired half-life in intestine-like environment

    KAUST Repository

    Sharma, Arun

    2014-08-20

    Background: In past, a number of peptides have been reported to possess highly diverse properties ranging from cell penetrating, tumor homing, anticancer, anti-hypertensive, antiviral to antimicrobials. Owing to their excellent specificity, low-toxicity, rich chemical diversity and availability from natural sources, FDA has successfully approved a number of peptide-based drugs and several are in various stages of drug development. Though peptides are proven good drug candidates, their usage is still hindered mainly because of their high susceptibility towards proteases degradation. We have developed an in silico method to predict the half-life of peptides in intestine-like environment and to design better peptides having optimized physicochemical properties and half-life.Results: In this study, we have used 10mer (HL10) and 16mer (HL16) peptides dataset to develop prediction models for peptide half-life in intestine-like environment. First, SVM based models were developed on HL10 dataset which achieved maximum correlation R/R2 of 0.57/0.32, 0.68/0.46, and 0.69/0.47 using amino acid, dipeptide and tripeptide composition, respectively. Secondly, models developed on HL16 dataset showed maximum R/R2 of 0.91/0.82, 0.90/0.39, and 0.90/0.31 using amino acid, dipeptide and tripeptide composition, respectively. Furthermore, models that were developed on selected features, achieved a correlation (R) of 0.70 and 0.98 on HL10 and HL16 dataset, respectively. Preliminary analysis suggests the role of charged residue and amino acid size in peptide half-life/stability. Based on above models, we have developed a web server named HLP (Half Life Prediction), for predicting and designing peptides with desired half-life. The web server provides three facilities; i) half-life prediction, ii) physicochemical properties calculation and iii) designing mutant peptides.Conclusion: In summary, this study describes a web server \\'HLP\\' that has been developed for assisting scientific

  12. 18F half-life measurement using a high-purity germanium detector

    International Nuclear Information System (INIS)

    Han, Jubong; Lee, K.B.; Park, T.S.; Lee, J.M.; Oh, P.J.; Lee, S.H.; Kang, Y.S.; Ahn, J.K.

    2012-01-01

    The half-life of 18 F has been measured using HPGe detectors with a 137 Cs reference source. The counting ratio of 511 keV γ-rays from 18 F to 622 keV γ-rays from 137 Cs was fitted for the half-life with a weighted least-square method. Uncertainties due to the systematic effects arising from the measurement of a high activity 18 F source were studied in detail. The half-life of 18 F was found to be (109.72±0.19) min. The result is in a good agreement with the recommended value of (109.728±0.019) min evaluated at the Laborotaire National Henri Becquerel (LNHB). - Highlights: ► The 18 F half-life was measured with a reference source and without it using HPGe detectors. ► We found the systematic effect ‘activity dynamic range effect’ by monitoring the counts of the reference source. ► This activity dynamic range effect was corrected by using the reference source method. ► The 18 F half-life using the reference source method was in a good agreement with the recommended value of LNHB.

  13. The half-life of 207Bi and decays of 211At and 211Po

    International Nuclear Information System (INIS)

    Yanokura, M.; Kudo, H.; Nakahara, H.; Miyano, K.; Ohya, S.; Nitoh, O.

    1978-01-01

    The half-life of 207 Bi was obtained from the genetic relation between 207 Po and 207 Bi, and between 211 At and 207 Bi. The half-life was found to be 33.4 +- 0.8 y. The half-life of 207 Po was determined to be 5.81 +- 0.04 h by following the decay of the characteristic γ-rays from 207 Po. The half-life of 211 At was determined to be 7.23 +- 0.02 h by following the decay of γ-rays and α-particles from 211 At and 211 Po. The half-lives determined in the present work for 207 Po and 211 At agree with the literature although the half-life of 207 Bi differs considerably from the currently accepted value of 38 y. The branching ratio of 211 At decaying through EC and α-decay modes was determined together with the branching ratios of the three α-particles emitted from 211 Po. (Auth.)

  14. Re-measurement of the half-life of sup 7 sup 9 Se

    CERN Document Server

    Jiang Song Sheng; Diao Li Jun; Li Chun Shen; GouJingRu; Wu Shao Yon

    2002-01-01

    A new attempt has been made for the re-measurement of the half-life of sup 7 sup 9 Se. We made two major improvements over our earlier sup 7 sup 9 Se half-life determination (Nucl. Instr. and Meth. B 123 (1997) 403). Firstly, the half-life of sup 7 sup 9 Se was measured relative to the precisely known half-life of sup 7 sup 5 Se, rather than an absolute measurement of sup 7 sup 9 Se/Se. Secondly, the Projectile X-ray Detection technique was used for the separation of sup 7 sup 9 Se from its isobar, sup 7 sup 9 Br, rather than measuring sup 8 sup 1 Br for the deduction of sup 7 sup 9 Br interference, and this technique was also used for separation of sup 7 sup 5 Se and its isobar, sup 7 sup 5 As. A detailed description of the sample preparations, experimental setup and measurements are given. The re-measured half-life of sup 7 sup 9 Se was (2.95+-0.38)x10 sup 5 a, about a factor of 3 lower than the previous value, 1.1x10 sup 6 a. The problems in the previous measurement are discussed.

  15. High-precision half-life determination for the superallowed β+ emitter Ga62

    Science.gov (United States)

    Grinyer, G. F.; Finlay, P.; Svensson, C. E.; Ball, G. C.; Leslie, J. R.; Austin, R. A. E.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Hackman, G.; Hyland, B.; Kanungo, R.; Leach, K. G.; Mattoon, C. M.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Savajols, H.; Schumaker, M. A.; Wong, J.

    2008-01-01

    The half-life of the superallowed β+ emitter Ga62 has been measured at TRIUMF's Isotope Separator and Accelerator facility using a fast-tape-transport system and 4π continuous-flow gas proportional counter to detect the positrons from the decay of Ga62 to the daughter Zn62. The result, T1/2=116.100±0.025 ms, represents the most precise measurement to date (0.022%) for any superallowed β-decay half-life. When combined with six previous measurements of the Ga62 half-life, a new world average of T1/2=116.121±0.021 ms is obtained. This new half-life measurement results in a 20% improvement in the precision of the Ga62 superallowed ft value while reducing its mean by 0.9σ to ft=3074.3(12) s. The impact of this half-life measurement on precision tests of the CVC hypothesis and isospin symmetry breaking corrections for A⩾62 superallowed decays is discussed.

  16. Determination of plutonium-241 half-life by mass spectrometric measurement

    International Nuclear Information System (INIS)

    Hiyama, Takashi; Wada, Yukio; Onishi, Koichi

    1982-01-01

    Much data for Pu-241 half-life have been reported, but these values range from 13.8 years to 15.1 years depending on investigators. In order to define the half-life of Pu-241, the half-life was calculated by analyzing the mass spectrometry data obtained in the author's laboratory over the past six years on Plutonium Isotopic Standard Reference Materials prepared at the National Bureau of Standards (NBS). The sample used for this work consisted of SRM-947 and SRM-948 prepared at NBS. Before mass spectrometric analysis, the plutonium aliquot was separated from its Am-241 daughter by anion exchange chromatography, since Am-241 is not distinguished from Pu-241 in the mass spectrometer. 241 Pu/ 239 Pu and 241 Pu/ 240 Pu ratios were calculated from the values of mass spectrometric measurement. From the relation of log N to time, the half-life of Pu-241 was determined, based on the slope using a least squares fit. The half-life of Pu-241 was estimated to be 14.29+-0.15 years. (Yoshitake, I.)

  17. An albumin-oligonucleotide assembly for potential combinatorial drug delivery and half-life extension applications

    DEFF Research Database (Denmark)

    Kuhlmann, Matthias; Hamming, Jonas Bohn Refslund; Voldum, Anders

    2017-01-01

    The long blood circulatory property of human serum albumin, due to engagement with the cellular recycling neonatal Fc receptor (FcRn), is an attractive drug half-life extension enabling technology. This work describes a novel site-specific albumin double-stranded (ds) DNA assembly approach, in wh...... technology platform that offers potential combinatorial drug delivery and half-life extension applications.......The long blood circulatory property of human serum albumin, due to engagement with the cellular recycling neonatal Fc receptor (FcRn), is an attractive drug half-life extension enabling technology. This work describes a novel site-specific albumin double-stranded (ds) DNA assembly approach......, in which the 3' or 5' end maleimide-derivatized oligodeoxynucleotides are conjugated to albumin cysteine at position 34 (cys34) and annealed with complementary strands to allow single site-specific protein modification with functionalized ds oligodeoxynucleotides. Electrophoretic gel shift assays...

  18. Improving the control of systematic uncertainties in precision measurements of radionuclide half-life

    International Nuclear Information System (INIS)

    Towers, S.

    2013-01-01

    Many experiments designed to precisely determine the half-life of a radionuclide employ a long lived reference source to help determine the impact on the data of any systematic variation in the detector and associated electronics. The half-life of the radionuclide of interest is determined from the ratio of its decay rate data to the decay rate data from the reference source. This correction procedure assumes that any underlying systematic affects the data and reference measurements in exactly the same way. In this paper we show that when some systematic effects affect the two differently, the ratio procedure can leave artifacts in the corrected data that can compromise an unbiased and precise assessment of the radionuclide half-life. We describe two methods that can help overcome this problem. We also describe several statistical tests that help determine which effects may underlie systematic variations in the data. We discuss an illustrative example based on previously published 32 Si and 36 Cl data recorded by an experiment at Brookhaven National Laboratory. We correct the data for systematic variation related to climate variation and estimate the 32 Si half-life to be T 1/2 =171.8±1.8. The reduction in uncertainty in the 32 Si half-life, relative to the previous estimate based upon this data, is equivalent to that which would be achieved through increasing the size of the data set by almost 3.5 times. - Author-Highlights: • Isotope decay data and reference source data can have differing systematics. • Differing systematics can inflate uncertainty of isotope half-life estimate. • We describe two methods to overcome this problem. • We describe statistical tests to determine which variables cause systematics. • We analyze Brookhaven 32Si/36Cl decay data as an illustrative example

  19. Precision half-life measurement of 11C: The most precise mirror transition F t value

    Science.gov (United States)

    Valverde, A. A.; Brodeur, M.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Blankstein, D.; Brown, G.; Burdette, D. P.; Frentz, B.; Gilardy, G.; Hall, M. R.; King, S.; Kolata, J. J.; Long, J.; Macon, K. T.; Nelson, A.; O'Malley, P. D.; Skulski, M.; Strauss, S. Y.; Vande Kolk, B.

    2018-03-01

    Background: The precise determination of the F t value in T =1 /2 mixed mirror decays is an important avenue for testing the standard model of the electroweak interaction through the determination of Vu d in nuclear β decays. 11C is an interesting case, as its low mass and small QE C value make it particularly sensitive to violations of the conserved vector current hypothesis. The present dominant source of uncertainty in the 11CF t value is the half-life. Purpose: A high-precision measurement of the 11C half-life was performed, and a new world average half-life was calculated. Method: 11C was created by transfer reactions and separated using the TwinSol facility at the Nuclear Science Laboratory at the University of Notre Dame. It was then implanted into a tantalum foil, and β counting was used to determine the half-life. Results: The new half-life, t1 /2=1220.27 (26 ) s, is consistent with the previous values but significantly more precise. A new world average was calculated, t1/2 world=1220.41 (32 ) s, and a new estimate for the Gamow-Teller to Fermi mixing ratio ρ is presented along with standard model correlation parameters. Conclusions: The new 11C world average half-life allows the calculation of a F tmirror value that is now the most precise value for all superallowed mixed mirror transitions. This gives a strong impetus for an experimental determination of ρ , to allow for the determination of Vu d from this decay.

  20. The impact of extended half-life versus conventional factor product on hemophilia caregiver burden.

    Science.gov (United States)

    Schwartz, Carolyn E; Powell, Victoria E; Su, Jun; Zhang, Jie; Eldar-Lissai, Adi

    2018-05-01

    Extended half-life factor products have reduced annualized bleeding rates in hemophilia patients. The impact of extended half-life versus conventional factor products on hemophilia caregiver burden has not been investigated. This study aimed to evaluate caregiver burden in extended half-life versus conventional factor products for hemophilia A and B. This cross-sectional web-based study of caregivers of people with hemophilia A or B was recruited from a panel research company and by word of mouth. Participants completed the Hemophilia Caregiver Impact measure, the PedsQL Family Impact Module (PedsQL), and the Work Productivity and Activity Impairment Questionnaire (WPAI). We also collected demographic, insurance coverage, and medical information related to the hemophilia patient(s). Burden differences were assessed using linear regression and matched cohort analyses. The sample (n = 448) included 49 people who were caring for people on extended half-life factor products. Worse caregiver burden was associated with more infusions per week and more bleeds in the past 6 months. Regression analyses suggested that caring for someone who is on a extended half-life factor product is associated with lower emotional impact (β = - 0.11, p factor product had lower Emotional Impact and Practical Impact scores (t = - 2.95 and - 2.94, respectively, p factor product infusions of extended half-life factor products appears to reduce the emotional distress and practical burden of caregiving. Future work should evaluate the longitudinal impact.

  1. Tests of a Fast Plastic Scintillator for High-Precision Half-Life Measurements

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Leach, K. G.; Michetti-Wilson, J.; Rand, E. T.; Svensson, C. E.; Grinyer, G. F.; Thomas, J. C.; Ball, G.; Garnsworthy, A. B.; Hackman, G.; Orce, J. N.; Triambak, S.; Williams, S. J.; Andreoiu, C.; Cross, D.

    2013-03-01

    A fast plastic scintillator detector is evaluated for possible use in an ongoing program of high-precision half-life measurements of short lived β emitters. Using data taken at TRI-UMF's Isotope Separator and Accelerator Facility with a radioactive 26Na beam, a detailed investigation of potential systematic effects with this new detector setup is being performed. The technique will then be applied to other β-decay half-life measurements including the superallowed Fermi β emitters 10C, 14O, and T = 1/2 decay of 15O.

  2. Determination of half life of tellurium isotopes: a proposal for the teaching of nuclear physics

    International Nuclear Information System (INIS)

    Ruivo, Julio C.; Zamboni, Cibele B.; Batista, Wagner F.

    2013-01-01

    This work aimed at the development of courseware for teaching nuclear physics, using experimental data of half-life measurement (T1/2) of Tellurium isotopes (A=127 and 131). The choice of Tellurium was established for providing nuclear data, which are fundamental in related investigations of nuclear structure and its use in various areas such as geochemistry, chemical and pharmaceutical industries, astrophysics etc. For evaluation of the proposal performance, the material was made available, bringing a lot of information about nuclear safety, production and storage of radioactive material and concepts of radioactive decay, subatomic particles, emission of gamma radiation, half-life, etc.

  3. Determination of half life of tellurium isotopes: a proposal for the teaching of nuclear physics

    Energy Technology Data Exchange (ETDEWEB)

    Ruivo, Julio C.; Zamboni, Cibele B.; Batista, Wagner F., E-mail: julio.ruivo.costa@usp.br, E-mail: czamboni@ipen.br, E-mail: fisicawagner@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    This work aimed at the development of courseware for teaching nuclear physics, using experimental data of half-life measurement (T1/2) of Tellurium isotopes (A=127 and 131). The choice of Tellurium was established for providing nuclear data, which are fundamental in related investigations of nuclear structure and its use in various areas such as geochemistry, chemical and pharmaceutical industries, astrophysics etc. For evaluation of the proposal performance, the material was made available, bringing a lot of information about nuclear safety, production and storage of radioactive material and concepts of radioactive decay, subatomic particles, emission of gamma radiation, half-life, etc.

  4. Application of genetic algorithms for determination biological half-life of 137 Cs in milk

    International Nuclear Information System (INIS)

    Pantelic, G.

    1998-01-01

    Genetic algorithm an optimization method involving natural selection mechanisms, was used to determine biological half-life of sup 1 sup 3 sup 7 Cs in the milk, after the Chernobyl accident, based on a two compartment linear system model. Genetic algorithms operate on populations of strings. Reproduction, crossover and mutation are applied to successive string population to create new string population. A model parameter estimation is performed by minimizing square differences between fitting function and experimental data. The calculated biological half-life of sup 1 sup 3 sup 7 Cs in milk is (32(+(-) days (author)

  5. Study of the half-life of 123I and the determination of possible radionuclidic impurities

    International Nuclear Information System (INIS)

    Delgado, Jose Ubiratan; Araujo, Miriam Taina Ferreira de; Silva, Carlos Jose da; Araujo, Camila Cristina Cunha; Candido, Marcos Antonio; Pereira, Wagner do Prado

    2013-01-01

    During the process of production of the radiopharmaceutical nuclear reactor or cyclotron, impurities can be generated from biological, chemical and radionuclidic. The development of the present work was to study the half-life of Na 123 I sample produced in IEN (Institute of Nuclear Engineering) using the technique of gamma-ray spectrometry with germanium detector in order to Identify such impurities. The results Indicate values of half-life consistent with recent publications with a deviation of 0,08% and 0:11% of uncertainty as well as the identification of impurities to radionuclides 95m Tc, 96 Tc and 121 Te. (author)

  6. Degradation and half-life of DNA present in biomass from a genetically-modified organism during land application.

    Science.gov (United States)

    Halter, Mathew C; Zahn, James A

    2017-02-01

    White biotechnology has made a positive impact on the chemical industry by providing safer, more efficient chemical manufacturing processes that have reduced the use of toxic chemicals, harsh reaction conditions, and expensive metal catalysts, which has improved alignment with the principles of Green Chemistry. The genetically-modified (GM) biocatalysts that are utilized in these processes are typically separated from high-value products and then recycled, or eliminated. Elimination routes include disposal in sanitary landfills, incineration, use as a fuel, animal feed, or reuse as an agricultural soil amendment or other value-added products. Elimination routes that have the potential to impact the food chain or environment have been more heavily scrutinized for the fate and persistence of biological products. In this study, we developed and optimized a method for monitoring the degradation of strain-specific DNA markers from a genetically-modified organism (GMO) used for the commercial production of 1,3-propanediol. Laboratory and field tests showed that a marker for heterologous DNA in the GM organism was no longer detectable by end-point polymerase chain reaction (PCR) after 14 days. The half-life of heterologous DNA was increased by 17% (from 42.4 to 49.7 h) after sterilization of the soil from a field plot, which indicated that abiotic factors were important in degradation of DNA under field conditions. There was no evidence for horizontal transfer of DNA target sequences from the GMO to viable organisms present in the soil.

  7. The interaction between thermodynamic stability and buried free cysteines in regulating the functional half-life of fibroblast growth factor-1.

    Science.gov (United States)

    Lee, Jihun; Blaber, Michael

    2009-10-16

    Protein biopharmaceuticals are an important and growing area of human therapeutics; however, the intrinsic property of proteins to adopt alternative conformations (such as during protein unfolding and aggregation) presents numerous challenges, limiting their effective application as biopharmaceuticals. Using fibroblast growth factor-1 as model system, we describe a cooperative interaction between the intrinsic property of thermostability and the reactivity of buried free-cysteine residues that can substantially modulate protein functional half-life. A mutational strategy that combines elimination of buried free cysteines and secondary mutations that enhance thermostability to achieve a substantial gain in functional half-life is described. Furthermore, the implementation of this design strategy utilizing stabilizing mutations within the core region resulted in a mutant protein that is essentially indistinguishable from wild type as regard protein surface and solvent structure, thus minimizing the immunogenic potential of the mutations. This design strategy should be generally applicable to soluble globular proteins containing buried free-cysteine residues.

  8. On the biological half-life of caesium in pregnant women and infants

    International Nuclear Information System (INIS)

    Rundo, J.; Turner, F.M.

    1992-01-01

    In the 1960s, changes were observed in the levels of 137 Cs in women who were pregnant or who had recently given birth. These were not associated with changes in the rate of fall-out, and were interpreted as the consequences of changes in the biological half-life. It was deduced that the biological half-life of caesium just before parturition averaged 59% of the value (87±33 days) after the birth of the baby; and that there was a step change at parturition. The behaviour of the levels during pregnancy suggested there was a gradual decrease in the biological half-life. Similar measurements were made in very young children. The concentration of the radionuclide in a breast-fed baby was usually a little less than that in the mother, indicating some discrimination in the transfer from plasma to milk; the concentration in a bottle-fed baby increased substantially and rapidly from the level at or shortly after birth. Data for three babies were sufficiently extensive to permit determination of the biological half-life in each. Values of 8.7±0.6 days, 15.4±1.1 days, and 14.9±3.6 days were derived. (author)

  9. Radionuclide biological half-life values for terrestrial and aquatic wildlife

    International Nuclear Information System (INIS)

    Beresford, N.A.; Beaugelin-Seiller, K.; Burgos, J.; Cujic, M.; Fesenko, S.; Kryshev, A.; Pachal, N.; Real, A.; Su, B.S.; Tagami, K.; Vives i Batlle, J.; Vives-Lynch, S.; Wells, C.; Wood, M.D.

    2015-01-01

    The equilibrium concentration ratio is typically the parameter used to estimate organism activity concentrations within wildlife dose assessment tools. Whilst this is assumed to be fit for purpose, there are scenarios such as accidental or irregular, fluctuating, releases from licensed facilities when this might not be the case. In such circumstances, the concentration ratio approach may under- or over-estimate radiation exposure depending upon the time since the release. To carrying out assessments for such releases, a dynamic approach is needed. The simplest and most practical option is representing the uptake and turnover processes by first-order kinetics, for which organism- and element-specific biological half-life data are required. In this paper we describe the development of a freely available international database of radionuclide biological half-life values. The database includes 1907 entries for terrestrial, freshwater, riparian and marine organisms. Biological half-life values are reported for 52 elements across a range of wildlife groups (marine = 9, freshwater = 10, terrestrial = 7 and riparian = 3 groups). Potential applications and limitations of the database are discussed. - Highlights: • 1907 biological half-life values have been collated for wildlife species. • Data cover 52 elements. • 27 marine, freshwater, riparian and terrestrial organisms are included.

  10. Safety and Efficacy of BAY 94-9027, a Prolonged-Half-Life Factor VIII

    DEFF Research Database (Denmark)

    Reding, M T; Ng, H J; Poulsen, Lone Hvitfeldt

    2017-01-01

    BACKGROUND: BAY 94-9027 is a B-domain-deleted prolonged-half-life recombinant factor VIII (FVIII) conjugates in a site-specific manner with polyethylene glycol. OBJECTIVE: Assess efficacy and safety of BAY 94-9027 for prophylaxis and treatment of bleeds in patients with severe hemophilia A PATIEN...

  11. Effect of parent and daughter deformation on half-life time in exotic ...

    Indian Academy of Sciences (India)

    Shi and Swiatecki [6] put forward a model for exotic decay studies that uses Coulomb and proximity potential as interacting barrier for post-scission region and uses simple power law for overlap region. These authors [7] studied the effect of deformation of parent, daughter and shell attenuation on half-life time treating ...

  12. Dependence of the half-life of 221Fr on the implantation environment

    DEFF Research Database (Denmark)

    Olaizola, B.; Fraile, L.M.; Riisager, Karsten

    2010-01-01

    The possible dependence of the half-life of 221Fr on the solid-state environment has been investigated by the simultaneous measurement of implanted 221Fr ions in an insulator (Si) and a metallic substrate (Au) at the ISOLDE facility at CERN. Our results indicate that, if existing, the difference ...

  13. Precision half-life measurement of .sup.140 La with Ge-detector

    Czech Academy of Sciences Publication Activity Database

    Adam, Jindřich; Belov, A. G.; Brandt, R.; Chaloun, P.; Honusek, Milan; Kalinnikov, V. G.; Krivopustov, M. I.; Kulakov, B. A.; Langrock, E. J.; Pronskikh, V. S.; Sosnin, A. N.; Stegailov, V. I.; Tsoupko-Sitnikov, V. M.; Wan, J. S.; Westmeier, W.

    2002-01-01

    Roč. 187, - (2002), s. 419-426 ISSN 0168-583X R&D Projects: GA AV ČR KSK1048102 Keywords : radioastive nuclei * Ge-detectors * half-life measurements Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.158, year: 2002

  14. On the half-life of luminescence signals in dosimetric applications: A unified presentation

    Science.gov (United States)

    Pagonis, V.; Kitis, G.; Polymeris, G. S.

    2018-06-01

    Luminescence signals from natural and man-made materials are widely used in dosimetric and dating applications. In general, there are two types of half-lives of luminescence signals which are of importance to experimental and modeling work in this research area. The first type of half-life is the time required for the population of the trapped charge in a single trap to decay to half its initial value. The second type of half-life is the time required for the luminescence intensity to drop to half of its initial value. While there a handful of analytical expressions available in the literature for the first type of half-life, there are no corresponding analytical expressions for the second type. In this work new analytical expressions are derived for the half-life of luminescence signals during continuous wave optical stimulation luminescence (CW-OSL) or isothermal luminescence (ITL) experiments. The analytical expressions are derived for several commonly used luminescence models which are based on delocalized transitions involving the conduction band: first and second order kinetics, empirical general order kinetics (GOK), mixed order kinetics (MOK) and the one-trap one-recombination center (OTOR) model. In addition, half-life expressions are derived for a different type of luminescence model, which is based on localized transitions in a random distribution of charges. The new half-life expressions contain two parts. The first part is inversely proportional to the thermal or optical excitation rate, and depends on the experimental conditions and on the cross section of the relevant luminescence process. The second part is characteristic of the optical and/or thermal properties of the material, as expressed by the parameters in the model. A new simple and quick method for analyzing luminescence signals is developed, and examples are given of applying the new method to a variety of dosimetric materials. The new test allows quick determination of whether a set of

  15. A half-life the divided life of Bruno Pontecorvo, physicist or spy

    CERN Document Server

    Close, Frank

    2015-01-01

    Bruno Pontecorvo dedicated his career to hunting for the Higgs boson of his day: the neutrino, a nearly massless particle considered essential to the process of nuclear fission. His work on the Manhattan project under Enrico Fermi confirmed his reputation as a brilliant physicist and helped usher in the nuclear age. He should have won a Nobel Prize, but late in the summer of 1950 he vanished. At the height of the Cold War, Pontecorvo had disappeared behind the Iron Curtain. In Half-Life, physicist and historian Frank Close offers a heretofore untold history of Pontecorvo’s life, based on unprecedented access to his friends, family, and colleagues. With all the elements of a Cold War thriller—classified atomic research, an infamous double agent, a kidnapping by Soviet operatives—Half-Life is a history of particle physics at perhaps its most powerful: when it created the bomb.

  16. Determination of {sup 126}Sn half-life from ICP-MS and gamma spectrometry measurements

    Energy Technology Data Exchange (ETDEWEB)

    Bienvenu, P.; Arnal, N.; Comte, J. [CEA Cadarache DEN/DEC/SA3C/LARC, Paul Lez Durance (France); Ferreux, L.; Lepy, M.C.; Be, M.M. [CEA Saclay LIST LNE/LNHB, Gif sur Yvette (France); Andreoletti, G. [AREVA Cogema SL/UP2-800, Beaumont Hague (France)

    2009-07-01

    A new value of {sup 126}Sn half-life was determined by combination of inductively coupled plasma-mass spectrometry (ICP-MS) and gamma spectrometry measurements on purified sample solutions collected from nuclear fuel reprocessing. {sup 126}Sn was isolated through dissolution of fission product precipitates and liquid-liquid extraction with N-benzoyl-N-phenyl-hydroxylamine (BPHA). The abundance of {sup 126}Sn atoms together with the absence of interfering species in the analysed solutions made it possible to measure both mass concentration and nuclide activity with high precision and accuracy. This led to a {sup 126}Sn half-life value of 1.980 (57) x 10{sup 5} a. (orig.)

  17. High-Precision Half-Life Measurement for the Superallowed β+ Emitter Alm26

    Science.gov (United States)

    Finlay, P.; Ettenauer, S.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.

    2011-01-01

    A high-precision half-life measurement for the superallowed β+ emitter Alm26 was performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1/2=6346.54±0.46stat±0.60systms, consistent with, but 2.5 times more precise than, the previous world average. The Alm26 half-life and ft value, 3037.53(61) s, are now the most precisely determined for any superallowed β decay. Combined with recent theoretical corrections for isospin-symmetry-breaking and radiative effects, the corrected Ft value for Alm26, 3073.0(12) s, sets a new benchmark for the high-precision superallowed Fermi β-decay studies used to test the conserved vector current hypothesis and determine the Vud element of the Cabibbo-Kobayashi-Maskawa quark mixing matrix.

  18. High-Precision Half-life Measurements for the Superallowed β+ Emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E. R.; Thomas, J. C.; Unsworth, C.

    2014-03-01

    The half-life of 14O, a superallowed Fermi β+ emitter, has been determined via simultaneous γ and β counting experiments at TRIUMF's Isotope Separator and Accelerator facility. Following the implantation of 14O samples at the center of the 8π spectrometer, a γ counting measurement was performed by detecting the 2313 keV γ-rays emitted from the first excited state of the daughter 14N using 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned directly behind the implantation site. The results, T½(γ) = 70:632 ± 0:094 s and T½(β) = 70:610 ± 0:030 s, are consistent with one another and, together with eight previous measurements, establish a new average for the 14O half-life of T½ = 70:619 ± 0:011 s with a reduced χ2 of 0.99.

  19. Half-life and intensities of photons of 103Pd isotope

    International Nuclear Information System (INIS)

    Popov, Yu.S.; Zakharova, L.V.; Kupriyanov, V.N.; Andreev, O.I.; Pakhomov, A.N.; Vakhetov, F.Z.

    2001-01-01

    Half-life and intensities of photons forming during 103 Pd isotope decay are determined by the methods of semiconductor x-ray and γ-spectrometry. 103 Pd is applied in nuclear medicine for preparation of 103m Rh isomer (T 1/2 =56 min) being used in irradiation of prostate neoplasms. Half-life of 103 Pd isotope is 16±0.6 days, relative intensities of x-ray and γ-photons are: K α /Kβ=5.1±0.4; 358 keV - 100 rel.units; 295 keV - 12.3±0.4 rel.units; 497 keV - 17.6±0.6 rel.units. Errors are represented for confidence probability 95 % [ru

  20. A New Method to Determine the Half-Life for Penicillin Using Microcalorimeter

    Science.gov (United States)

    Li, Z. X.; Zhao, W. W.

    2015-01-01

    The dissolution process of penicillin in normal saline and isotonic glucose solution was reported using a microcalorimeter. Both the integral and differential heats of solution were measured. The quantitative relationships between the amount of heat released and the quantity of dissolved penicillin were established. Meanwhile, the kinetics and the half-life of the dissolution processes as well as the enthalpy of solution, the entropy of dissolution, and the free energy of dissolution were determined. The results showed that a change of the solvent from normal saline to isotonic glucose solution had little effect on the half-life of penicillin in the dissolution process, and there was no significant difference between the stabilities of penicillin in isotonic glucose solution and normal saline. Moreover, the dissolution process of penicillin in isotonic glucose solution followed the first-order kinetics. These results could provide a theoretical basis for the clinical applications of penicillin.

  1. Biological half-life of radiophosphorus in desert locust, Schistocerca gregaria Forskal (orthoptera:acrididae)

    International Nuclear Information System (INIS)

    Ulagaraj, S.M.; Singh, K.M.; Sethi, G.R.

    1975-01-01

    Adult desert locust, Schistocerca gregaria Forskal were fed with cabbage leaves, painted with carrier free 32 P 1mCi/ml. Radioactivity of five adults of both sexes and of feces was measured daily for 28 days. The amount of radioactivity appearing in the feces of males was consistently below that found in female locusts. The mean biological half-life of 32 P for males and females were 35.04 and 15.01 days, respectively. (author)

  2. Neutron activation analyses and half-life measurements at the usgs triga reactor

    Science.gov (United States)

    Larson, Robert E.

    Neutron activation of materials followed by gamma spectroscopy using high-purity germanium detectors is an effective method for making measurements of nuclear beta decay half-lives and for detecting trace amounts of elements present in materials. This research explores applications of neutron activation analysis (NAA) in two parts. Part 1. High Precision Methods for Measuring Decay Half-Lives, Chapters 1 through 8 Part one develops research methods and data analysis techniques for making high precision measurements of nuclear beta decay half-lives. The change in the electron capture half-life of 51Cr in pure chromium versus chromium mixed in a gold lattice structure is explored, and the 97Ru electron capture decay half-life are compared for ruthenium in a pure crystal versus ruthenium in a rutile oxide state, RuO2. In addition, the beta-minus decay half-life of 71mZn is measured and compared with new high precision findings. Density Functional Theory is used to explain the measured magnitude of changes in electron capture half-life from changes in the surrounding lattice electron configuration. Part 2. Debris Collection Nuclear Diagnostic at the National Ignition Facility, Chapters 9 through 11 Part two explores the design and development of a solid debris collector for use as a diagnostic tool at the National Ignition Facility (NIF). NAA measurements are performed on NIF post-shot debris collected on witness plates in the NIF chamber. In this application NAA is used to detect and quantify the amount of trace amounts of gold from the hohlraum and germanium from the pellet present in the debris collected after a NIF shot. The design of a solid debris collector based on material x-ray ablation properties is given, and calculations are done to predict performance and results for the collection and measurements of trace amounts of gold and germanium from dissociated hohlraum debris.

  3. Precise half-life measurement of the superallowed β+ emitter 38Km

    International Nuclear Information System (INIS)

    Ball, G. C.; Boisvert, G.; Bricault, P.; Churchman, R.; Dombsky, M.; Lindner, T.; Macdonald, J. A.; Vandervoort, E.; Bishop, S.; D'Auria, J. M.; Hardy, J. C.; Iacob, V. E.; Leslie, J. R.; Mak, H.-B.

    2010-01-01

    The half-life of 38 K m has been measured to be 924.46(14) ms, a result that is a factor of two more precise than any of the five previous measurements of this quantity. The previous results are not consistent with one another, but our result agrees well with the two most recent ones. The derived ft value for 38 K m is now one of the three most precisely known superallowed ft values.

  4. Increased Functional Half-life of Fibroblast Growth Factor-1 by Recovering a Vestigial Disulfide Bond

    Directory of Open Access Journals (Sweden)

    Jihun Lee

    2010-12-01

    Full Text Available The fibroblast growth factor (FGF family of proteins contains an absolutely conserved Cys residue at position 83 that is present as a buried free cysteine. We have previously shown that mutation of the structurally adjacent residue, Ala66, to cysteine results in the formation of a stabilizing disulfide bond in FGF-1. This result suggests that the conserved free cysteine residue at position 83 in the FGF family of proteins represents a vestigial half-cystine. Here, we characterize the functional half-life and mitogenic activity of the oxidized form of the Ala66Cys mutation to identify the effect of the recovered vestigial disulfide bond between Cys83 and Cys66 upon the cellular function of FGF-1. The results show that the mitogenic activity of this mutant is significantly increased and that its functional half-life is greatly extended. These favorable effects are conferred by the formation of a disulfide bond that simultaneously increases thermodynamic stability of the protein and removes a reactive buried thiol at position 83. Recovering this vestigial disulfide by introducing a cysteine at position 66 is a potentially useful protein engineering strategy to improve the functional half-life of other FGF family members.

  5. Measurements of Actual Effective Half - Life in 131I Therapy for Graves' Hyperthyroidism

    International Nuclear Information System (INIS)

    So, Yong Seon; Kim, Myung Seon; Kwon, Ki Hyun; Kim, Seok Whan; Kim, Tae Hyung; Han, Sang Woong; Kim, Eun Sil; Kim, Chong Soon

    1996-01-01

    Radioiodine[131I] has been used for the treatment of Graves' hyperthyroidism since the late 1940's and is now generally regarded as the treatment of choice for Graves' hyperthyroidism who does not remit following a course of antithyroid drugs. But for the dose given, several different protocols have been described by different centers, each attempting to reduce the incidence of long-term hypothyroidism while maintaining an acceptable rate control of Graves' hyperthyroidism. Our goals were to evaluate effective half-life and predict absorbed dose in Graves' hyperthyroidism patients, therefore, to calculate and read minister radioiodine activity needed to achieve aimed radiation dose. Our data showed that the mean effective 131I half-life for Graves' disease is 5.3 days(S.D=0.88) and mean biologic half-life is 21 days, range 9.5-67.2 days. The mean administered activity and the mean values of absorbed doses wet: 532 MBq(S.D.=254), 112 Gy (S.D.=50.9), respectively. The mean activity needed to achieve aimed radiation dose were 51 MBq and marked differences of 131I thyroidal uptake between tracer and therapy occurred in our study. We are sure that the dose calculation method that uses 5 days thyroidal 131I uptake measurements after tracer and therapy dose, provides sufficient data about the effective treatment in Graves' hyperthyroidism.

  6. Measurements of Actual Effective Half - Life in {sup 131}I Therapy for Graves' Hyperthyroidism

    Energy Technology Data Exchange (ETDEWEB)

    So, Yong Seon; Kim, Myung Seon; Kwon, Ki Hyun; Kim, Seok Whan; Kim, Tae Hyung; Han, Sang Woong; Kim, Eun Sil; Kim, Chong Soon [Hanil General Hospital, Seoul (Korea, Republic of)

    1996-03-15

    Radioiodine[131I] has been used for the treatment of Graves' hyperthyroidism since the late 1940's and is now generally regarded as the treatment of choice for Graves' hyperthyroidism who does not remit following a course of antithyroid drugs. But for the dose given, several different protocols have been described by different centers, each attempting to reduce the incidence of long-term hypothyroidism while maintaining an acceptable rate control of Graves' hyperthyroidism. Our goals were to evaluate effective half-life and predict absorbed dose in Graves' hyperthyroidism patients, therefore, to calculate and read minister radioiodine activity needed to achieve aimed radiation dose. Our data showed that the mean effective 131I half-life for Graves' disease is 5.3 days(S.D=0.88) and mean biologic half-life is 21 days, range 9.5-67.2 days. The mean administered activity and the mean values of absorbed doses wet: 532 MBq(S.D.=254), 112 Gy (S.D.=50.9), respectively. The mean activity needed to achieve aimed radiation dose were 51 MBq and marked differences of 131I thyroidal uptake between tracer and therapy occurred in our study. We are sure that the dose calculation method that uses 5 days thyroidal 131I uptake measurements after tracer and therapy dose, provides sufficient data about the effective treatment in Graves' hyperthyroidism.

  7. A novel exendin-4 human serum albumin fusion protein, E2HSA, with an extended half-life and good glucoregulatory effect in healthy rhesus monkeys

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ling; Wang, Lin; Meng, Zhiyun; Gan, Hui; Gu, Ruolan; Wu, Zhuona; Gao, Lei; Zhu, Xiaoxia; Sun, Wenzhong; Li, Jian; Zheng, Ying; Dou, Guifang, E-mail: douguifang@vip.163.com

    2014-03-07

    Highlights: • E2HSA has an extended half-life and good plasma stability. • E2HSA could improve glucose-dependent insulin secretion. • E2HSA has excellent glucoregulatory effects in vivo. • E2HSA could potentially be used as a new long-acting GLP-1 receptor agonist for type 2 diabetes management. - Abstract: Glucagon-like peptide-1 (GLP-1) has attracted considerable research interest in terms of the treatment of type 2 diabetes due to their multiple glucoregulatory functions. However, the short half-life, rapid inactivation by dipeptidyl peptidase-IV (DPP-IV) and excretion, limits the therapeutic potential of the native incretin hormone. Therefore, efforts are being made to develop the long-acting incretin mimetics via modifying its structure. Here we report a novel recombinant exendin-4 human serum albumin fusion protein E2HSA with HSA molecule extends their circulatory half-life in vivo while still retaining exendin-4 biological activity and therapeutic properties. In vitro comparisons of E2HSA and exendin-4 showed similar insulinotropic activity on rat pancreatic islets and GLP-1R-dependent biological activity on RIN-m5F cells, although E2HSA was less potent than exendin-4. E2HSA had a terminal elimation half-life of approximate 54 h in healthy rhesus monkeys. Furthermore, E2HSA could reduce postprandial glucose excursion and control fasting glucose level, dose-dependent suppress food intake. Improvement in glucose-dependent insulin secretion and control serum glucose excursions were observed during hyperglycemic clamp test (18 h) and oral glucose tolerance test (42 h) respectively. Thus the improved physiological characterization of E2HSA make it a new potent anti-diabetic drug for type 2 diabetes therapy.

  8. Fenobody: A Ferritin-Displayed Nanobody with High Apparent Affinity and Half-Life Extension.

    Science.gov (United States)

    Fan, Kelong; Jiang, Bing; Guan, Zhe; He, Jiuyang; Yang, Dongling; Xie, Ni; Nie, Guohui; Xie, Can; Yan, Xiyun

    2018-04-10

    Nanobodies consist of a single domain variable fragment of a camelid heavy-chain antibody. Nanobodies have potential applications in biomedical fields because of their simple production procedures and low cost. Occasionally, nanobody clones of interest exhibit low affinities for their target antigens, which, together with their short half-life limit bioanalytical or therapeutic applications. Here, we developed a novel platform we named fenobody, in which a nanobody developed against H5N1 virus is displayed on the surface of ferritin in the form of a 24mer. We constructed a fenobody by substituting the fifth helix of ferritin with the nanobody. TEM analysis showed that nanobodies were displayed on the surface of ferritin in the form of 6 × 4 bundles, and that these clustered nanobodies are flexible for antigen binding in spatial structure. Comparing fenobodies with conventional nanobodies currently used revealed that the antigen binding apparent affinity of anti-H5N1 fenobody was dramatically increased (∼360-fold). Crucially, their half-life extension in a murine model was 10-fold longer than anti-H5N1 nanobody. In addition, we found that our fenobodies are highly expressed in Escherichia coli, and are both soluble and thermo-stable nanocages that self-assemble as 24-polymers. In conclusion, our results demonstrate that fenobodies have unique advantages over currently available systems for apparent affinity enhancement and half-life extension of nanobodies. Our fenobody system presents a suitable platform for various large-scale biotechnological processes and should greatly facilitate the application of nanobody technology in these areas.

  9. Measurement of the half-life of sup 1 sup 7 sup 6 Lu

    CERN Document Server

    Nir-El, Y

    1998-01-01

    The half-life of sup 1 sup 7 sup 6 Lu was determined by measuring the disintegration rate of a solution of lutetium oxide, using a calibrated HPGe detector, and found to be (3.69+-0.02)x10 sup 1 sup 0 y. It is recommended that the current adopted value be calculated from the grouping of three published values since 1983, including our value, the weighted mean of which is (3.73+-0.01)x10 sup 1 sup 0 y.

  10. Half-life of the 3/2/sup +/ level of /sup 119/Sn

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, M C; Gil, F B [Faculdade de Ciencias da Universidade de Lisboa, Lisbon (Portugal). Grupo de Espectroscopia Nuclear, Laboratorio de Fisica

    1976-01-01

    The half-life of the 3/2/sup +/, 23.87 keV level of /sup 119/Sn is measured by the delayed coincidence technique. Magnetic spectrometry associated with scintillation techniques and scintillation spectrometry only have been used. The results obtained with these techniques were respectively Tsub(1/2) = 17.87 +- 0.11 ns and Tsub(1/2) = 18.48 +- 0.30 ns. The measured reduced M1 transition probability is compared with the single-particle and Kisslinger and Sorensen model predictions.

  11. The Half Life of the 53 keV Level in {sup 197}Pt

    Energy Technology Data Exchange (ETDEWEB)

    Malmskog, S G

    1967-02-15

    The half life of the recently proposed 53 keV level in {sup 197}Pt has been measured to 18.5 {+-} 1.5 nsec using the delayed coincidence technique. This level, which is identified with the f{sub 5/2} single particle state, decays directly to the p{sub 1/2} ground state in {sup 197}Pt. The reduced E2 transition probability for this 53 keV transition has been deduced and compared with the results obtained for the corresponding transitions in other Pt, Hg, and Pb isotopes and with the theoretical predictions by Sorensen and by Wahlborn and Martinson.

  12. First 0ν half-life limit from the Gotthard xenon time projection chamber

    International Nuclear Information System (INIS)

    Wong, H.T.; Boehm, F.; Fisher, P.

    1991-01-01

    A xenon Time Projection Chamber with an active volume of 207 liters has been built to study 0ν and 2ν double beta decay in 136 Xe. The TPC has been installed in the Gotthard Tunnel Underground Laboratory, and is currently taking data with 5 atm of xenon enriched in 62.5% 136 Xe. The first 166 hours of data are presented. Based on this data set, we deduce a half-life limit of T(0 + → 0 + ) > 6.2 x 10 21 years for the 0ν mode, at a 90% C.L. (author)

  13. Precision half-life determination of a mirror β transition: The decay of 31S

    International Nuclear Information System (INIS)

    Bacquias, A.; Kurtukian-Nieto, T.; Ascher, P.; Audirac, L.; Blank, B.; Giovinazzo, J.; Aeystoe, J.; Elomaa, V.V.; Eronen, T.; Hakala, J.; Jokinen, A.; Kankainen, A.; Karvonen, P.; Kolhinen, V.S.; Moore, I.D.; Rahaman, S.; Reponen, M.; Rissanen, J.; Saastamoinen, A.; Souin, J.

    2012-01-01

    The half-life of the mirror β decay of 31 S has been measured at the IGISOL facility at the University of Jyvaeskylae. The value obtained is T 1/2 ( 31 S)=(2553.4±1.8) ms, in agreement with previous measurements, but with a precision that is better by a factor of ten than the literature value previously adopted. When the new result is combined with the Q EC value measured recently at JYFLTRAP, a precision of better than 10 -3 is obtained for the ft value. (orig.)

  14. Determination of the half-life of sup 1 sup 0 sup 5 sup m Rh

    CERN Document Server

    Kronenberg, A K; Weber, R; Esterlund, R A; Patzelt, P

    1998-01-01

    Following a fast chemical separation of Ru isotopes from a fission-product mixture, sup 1 sup 0 sup 5 sup m Rh was periodically extracted from its precursor (4.44-h sup 1 sup 0 sup 5 Ru) for measurements of its half-life. The new value for the T sub 1 sub / sub 2 of sup 1 sup 0 sup 5 sup m Rh of (43.0+-0.3) s resolves the long-standing conflict in the literature between the two earlier measured values of 45 and 30 s.

  15. Effect of change in half-life of Se-79 on the safety of HLW geological disposal system

    International Nuclear Information System (INIS)

    Ishihara, Yoshinao; Ishiguro, Katsuhiko; Umeki, Hiroyuki

    1999-11-01

    Se-79 is one of key radionuclides in the performance assessment of the geological disposal system. Based on recent measurements, it is possible that the half-life of Se-79 will be changed longer than the present value in most handbooks and tables of isotopes. This study presents performance assessment calculations to investigate the overall effect of change in half-life of Se-79 on the repository system safety. The total system performance analyses for Se-79 were carried out, which focussed on the Reference-Case of the safety assessment in the H12 Project. As results, the maximum release rate in Becquerel unit of Se-79 from the engineered barrier system with new half-life decreases about one order of magnitude than that with half-life used so far. It is, however, that the maximum release rate in Becquerel unit of Se-79 from the natural barrier system is almost same for both half-life because of the channelling effects of groundwater flow. Consequently, the calculated maximum dose rate of Se-79 with new half-life does not change. It can be concluded that the change in half-life of Se-79 does not affect overall safety of the H12 disposal concept. (author)

  16. Isolation of human anti-serum albumin Fab antibodies with an extended serum-half life.

    Science.gov (United States)

    Kang, Hyeon-Ju; Kim, Hye-Jin; Cha, Sang-Hoon

    2016-01-01

    The serum albumin (SA) has been exploited to generate long-acting biotherapeutics by taking advantage of the FcRn-mediated recycling mechanism in a direct or an indirect way. Since Fab fragments have been proven to be clinically safe for human usage, we assumed that human anti-SA Fab antibodies could have a great potential as a carrier molecule to extend the serum half-life of therapeutic proteins. We, herein, had attempted to isolate anti-SA Fab antibodies from HuDVFab-8L antibody library via a phage display technology, and identified eight discrete human Fab antibodies. One of the Fab antibodies, SL335, showed the strongest binding reactivity to human SA with nM range of affinity at both pH 6 and pH 7.4, and cross-reacted to SAs from various species including rat, mouse, canine and monkey. The in vivo pharmacokinetic assay using a rat model indicated that SL335 has approximately 10 fold longer serum half-life and 26 to 44-fold increase in AUC0 → ∞ compared to the negative control Fab molecule in both intravenous and subcutaneous administrations. Knowing that Fabs have proven to be safe in clinics for a long time, SL335 seems to have a great potential in generating long-acting protein drugs by tagging effector molecules with either chemical conjugation or genetic fusion. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Preliminary measurements of the 87Rb half-life by means of the needle counter

    International Nuclear Information System (INIS)

    Zastawny, A.; Rabsztyn, B.

    1989-01-01

    In order to test the detector and to obtain the experience before starting the exact measurements, the measurements of 87 Rb half-life have been made. RbNO 3 produced by Merck was used to prepare the samples. The samples were prepared by evaporation of RbNO 3 water solution on an aluminium foil of 2,9 mg/cm 2 . The water solutions were changed in the range from (3286,4±1,8) x 10 -6 to (480,85±0,3) x 10 -6 . The background of the aluminium foil was equal to (0,117±0,007) cpm. In other measurements the back-scattering effect of 87 Rb beta rays on the aluminium foil amounted to 4%, as the measurements were performed in the 2π geometry. The diameters of samples were about 10 mm. The specific radioactivities of samples were measured versus the surface changed in the range (60-320) μg/cm 2 . The extrapolated value of the half-life, corrected for the chemical purity of the compound (as declared by the manufacterer) is equal to (4,86±0,1) x 10 10 years. This value is in good agreement with commonly accepted value of 4,88 x 10 10 years and with another last measurements. 10 refs., 1 fig., 2 tabs. (author)

  18. High-precision half-life measurements for the superallowed Fermi β+ emitter 14O

    Science.gov (United States)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E.; Thomas, J. C.; Unsworth, C.

    2013-07-01

    The half-life of the superallowed Fermi β+ emitter 14O has been determined via simultaneous direct β and γ counting experiments at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. A γ-ray counting measurement was performed by detecting the 2312.6-keV γ rays emitted from an excited state of the daughter 14N following the implantation of samples at the center of the 8π γ-ray spectrometer, a spherical array of 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned behind the implantation site with a solid angle coverage of ˜20%. The results, T1/2(β)=70.610±0.030s and T1/2(γ)=70.632±0.094s, form a consistent set and, together with eight previous measurements, establish a new average for the 14O half-life of T1/2=70.619±0.011s with a reduced χ2 of 0.99.

  19. A new simplified allometric approach for predicting the biological half-life of radionuclides in reptiles

    International Nuclear Information System (INIS)

    Beresford, N.A.; Wood, M.D.

    2014-01-01

    A major source of uncertainty in the estimation of radiation dose to wildlife is the prediction of internal radionuclide activity concentrations. Allometric (mass-dependent) relationships describing biological half-life (T 1/2b ) of radionuclides in organisms can be used to predict organism activity concentrations. The establishment of allometric expressions requires experimental data which are often lacking. An approach to predict the T 1/2b in homeothermic vertebrates has recently been proposed. In this paper we have adapted this to be applicable to reptiles. For Cs, Ra and Sr, over a mass range of 0.02–1.5 kg, resultant predictions were generally within a factor of 6 of reported values demonstrating that the approach can be used when measured T 1/2b data are lacking. However, the effect of mass on reptilian radionuclide T 1/2b is minimal. If sufficient measured data are available for a given radionuclide then it is likely that these would give a reasonable estimate of T 1/2b in any reptile species. - Highlights: • An allometric approach to predict radionuclide T 1/2b values in reptiles is derived. • Predictions are generally within a factor of six of measured values. • Radionuclide biological half-life is in-effect mass independent

  20. Half-life data--a critical review of TECDOC-619 update

    International Nuclear Information System (INIS)

    Woods, M.J.; Collins, S.M.

    2004-01-01

    An accurate knowledge of selected nuclear decay data is critical to a wide range of processes involving radionuclides. An IAEA publication in 1991 was dedicated to the evaluation of half-lives and specific gamma-ray emission probabilities for 39 selected radionuclides considered to be important for detector efficiency calibrations. A new exercise was initiated in December 1998 to update this previous evaluation and to include a number of new radionuclides of interest; 62 radionuclides were considered along with specific parent-daughter combinations (to give a total of 64 radionuclides). That work is now being completed and a new set of recommended data is being prepared for publication. A critical comparison of the 1991 and 2003 half-life data suggests that there has not been any significant improvement in the accuracy of the recommended data. The possible reasons for this situation are discussed together with the evaluation procedure and the quality of the available data. Proposals are made for concerted actions that could lead to a significant improvement in these recommended half-life data

  1. Estimating the biological half-life for radionuclides in homoeothermic vertebrates: a simplified allometric approach

    Energy Technology Data Exchange (ETDEWEB)

    Beresford, N.A. [Lancaster Environment Centre, NERC Centre for Ecology and Hydrology, Lancaster (United Kingdom); Vives i Batlle, J. [Belgian Nuclear Research Centre, Mol (Belgium)

    2013-11-15

    The application of allometric, or mass-dependent, relationships within radioecology has increased with the evolution of models to predict the exposure of organisms other than man. Allometry presents a method of addressing the lack of empirical data on radionuclide transfer and metabolism for the many radionuclide-species combinations which may need to be considered. However, sufficient data across a range of species with different masses are required to establish allometric relationships and this is not always available. Here, an alternative allometric approach to predict the biological half-life of radionuclides in homoeothermic vertebrates which does not require such data is derived. Biological half-life values are predicted for four radionuclides and compared to available data for a range of species. All predictions were within a factor of five of the observed values when the model was parameterised appropriate to the feeding strategy of each species. This is an encouraging level of agreement given that the allometric models are intended to provide broad approximations rather than exact values. However, reasons why some radionuclides deviate from what would be anticipated from Kleiber's law need to be determined to allow a more complete exploitation of the potential of allometric extrapolation within radioecological models. (orig.)

  2. HALO--a Java framework for precise transcript half-life determination.

    Science.gov (United States)

    Friedel, Caroline C; Kaufmann, Stefanie; Dölken, Lars; Zimmer, Ralf

    2010-05-01

    Recent improvements in experimental technologies now allow measurements of de novo transcription and/or RNA decay at whole transcriptome level and determination of precise transcript half-lives. Such transcript half-lives provide important insights into the regulation of biological processes and the relative contributions of RNA decay and de novo transcription to differential gene expression. In this article, we present HALO (Half-life Organizer), the first software for the precise determination of transcript half-lives from measurements of RNA de novo transcription or decay determined with microarrays or RNA-seq. In addition, methods for quality control, filtering and normalization are supplied. HALO provides a graphical user interface, command-line tools and a well-documented Java application programming interface (API). Thus, it can be used both by biologists to determine transcript half-lives fast and reliably with the provided user interfaces as well as software developers integrating transcript half-life analysis into other gene expression profiling pipelines. Source code, executables and documentation are available at http://www.bio.ifi.lmu.de/software/halo.

  3. High-precision half-life determination for 21Na using a 4 π gas-proportional counter

    Science.gov (United States)

    Finlay, P.; Laffoley, A. T.; Ball, G. C.; Bender, P. C.; Dunlop, M. R.; Dunlop, R.; Hackman, G.; Leslie, J. R.; MacLean, A. D.; Miller, D.; Moukaddam, M.; Olaizola, B.; Severijns, N.; Smith, J. K.; Southall, D.; Svensson, C. E.

    2017-08-01

    A high-precision half-life measurement for the superallowed β+ transition between the isospin T =1 /2 mirror nuclei 21Na and 21Ne has been performed at the TRIUMF-ISAC radioactive ion beam facility yielding T1 /2=22.4506 (33 ) s, a result that is a factor of 4 more precise than the previous world-average half-life for 21Na and represents the single most precisely determined half-life for a transition between mirror nuclei to date. The contribution to the uncertainty in the 21Na F tmirror value due to the half-life is now reduced to the level of the nuclear-structure-dependent theoretical corrections, leaving the branching ratio as the dominant experimental uncertainty.

  4. Study of the Bs meson and measurement of its half-life with the ALEPH detector

    International Nuclear Information System (INIS)

    Duarte, H.

    1994-01-01

    The B s 0 meson is the bound state of a quark anti-quark pair made up of a beauty particle and a strange particle. In the first chapter we review different experimental results leading to the existence of B S 0 meson and we draw the theoretical framework of the concept of beauty particles. The second chapter deals with the probability of the formation of a meson containing a strange quark during the fragmentation. This chapter also contains a re-analysis of the whole data constraining the mixing parameter B s 0 -B s 0 -bar. The relevancy of the analysis relies on the assumption that the B s 0 meson decays only into one D s , one lepton and one neutrino. The ALEPH detector is described in chapter 3, this four-pi, multi-particle detector is installed on the e + e - LEP (Large Electron Positron Collider). The signature selected for the measurement of the half-life is the combination of one D s in the decay modes: φπ, K *0 K with a lepton having opposite charge. This measurement implies the knowledge of the B s 0 momentum and of its flight length. In order to assess the momentum of the neutrino, a technique of measuring missing energy is presented in the chapter 4. The selection of B s 0 events is detailed in the chapter 5. A cutting limit on the energy of B s 0 based on the missing energy is used to deduce the production rate of B s 0 . In the chapter 6 we present the measurement of the half-life of B s 0 , the method used for the reconstruction of decay vertices and of the event main vertex is detailed. The validity of the method has been tested on Monte-Carlo simulations. The final result concerning the measurement of the half-life is: τ(B s )=[1.92(+0.45-0.35)±0.04] ps [fr

  5. Uptake, disposition, and elimination of acrylamide in rainbow trout

    International Nuclear Information System (INIS)

    Petersen, D.W.; Kleinow, K.M.; Kraska, R.C.; Lech, J.J.

    1985-01-01

    The uptake, disposition, and elimination of [2,3- 14 C]acrylamide was studied in fingerling rainbow trout exposed to 0.388 and 0.710 mg/liter [2,3- 14 C]acrylamide at 12 degrees C under static water conditions for 72 hr. 14 C in carcass and viscera was determined at times ranging from 4 to 72 hr after the beginning of the exposure period and 4 to 96 hr after transfer of the fish to fresh flowing water for the elimination studies. Uptake of 14 C was initially rapid and plateaued after 72 hr of acrylamide exposure. No appreciable bioaccumulation occurred in carcass or viscera at either exposure concentration and 14 C distributed approximately equally to all tissues studied. Elimination of 14 C from carcass and viscera was biphasic with a terminal half-life of approximately 7 days. 14 C elimination was not uniform in all tissues studied with the most rapid elimination occurring in blood and gill and the slowest elimination occurring in muscle and intestine. In addition, 10 to 15% of the initial total 14 C in carcass or viscera was nonextractable and was associated with the protein fraction of the sample at all time points in the depuration period. Approximately 20% of an ip administered dose of [ 14 C]acrylamide was eliminated via the gills, 7% via the urine, and less than 1% via the bile in 2 hr. At least three biliary metabolites were isolated by HPLC

  6. Going Beyond the Binary : The body, Sexuality and Identity in Shelley Jackson’s Half Life: a novel

    OpenAIRE

    Liu, Linjing

    2012-01-01

    The thesis focuses on Shelley Jackson’s Half Life: a Novel with efforts directed towards a literary interpretation considering relevant issues within the context of gender and feminist theory. The argument rests upon four basic units: the theoretical framework at the outset, the question of the body next, thirdly an investigation of sexuality, and finally a consideration of identity. In Jackson’s Half Life: a Novel the non-dualist thinking underlies a deliberate play of dualism. To go beyond ...

  7. ORIGEN-S Decay Data Library and Half-Life Uncertainties

    International Nuclear Information System (INIS)

    Hermann, O.W.

    1998-01-01

    The results of an extensive update of the decay data of the ORIGEN-S library are presented in this report. The updated decay data were provided for both the ORIGEN-S and ORIGEN2 libraries in the same project. A complete edit of the decay data plus the available half-life uncertainties are included in Appendix A. A detailed description of the types of data contained in the library, the format of the library, and the data sources are also presented. Approximately 24% of the library nuclides are stable, 66% were updated from ENDF/B-VI, about 8% were updated from ENSDF, and the remaining 2% were not updated. Appendix B presents a listing of percentage changes in decay heat from the old to the updated library for all nuclides containing a difference exceeding 1% in any parameter

  8. The antitumor agent 3-bromopyruvate has a short half-life at physiological conditions.

    Science.gov (United States)

    Glick, Matthew; Biddle, Perry; Jantzi, Josh; Weaver, Samantha; Schirch, Doug

    2014-09-12

    Clinical research is currently exploring the validity of the anti-tumor candidate 3-bromopyruvate (3-BP) as a novel treatment for several types of cancer. However, recent publications have overlooked rarely-cited earlier work about the instability of 3-BP and its decay to 3-hydroxypyruvate (3-HP) which have obvious implications for its mechanism of action against tumors, how it is administered, and for precautions when preparing solutions of 3-BP. This study found the first-order decay rate of 3-BP at physiological temperature and pH has a half-life of only 77 min. Lower buffer pH decreases the decay rate, while choice of buffer and concentration do not affect it. A method for preparing more stable solutions is also reported. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Half-life distribution table of radioactive nuclei; Table de distribution des periodes des noyaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Gugenberger, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [French] Cette table permet l'identification d'un element dont la periode est connue. Elle a ete etablie en utilisant les valeurs des periodes donnees par HOLLANDER, PERLMAN et SEABORG dans Rev. mod. Phys., 1953, 25 numero 2. On y trouve en outre, pour chaque nuclide, les caracteristiques suivantes: Z, A, modes de desintegration. (auteur)

  10. Development of CANDLES low background HPGe detector and half-life measurement of 180Tam

    Science.gov (United States)

    Chan, W. M.; Kishimoto, T.; Umehara, S.; Matsuoka, K.; Suzuki, K.; Yoshida, S.; Nakajima, K.; Iida, T.; Fushimi, K.; Nomachi, M.; Ogawa, I.; Tamagawa, Y.; Hazama, R.; Takemoto, Y.; Nakatani, N.; Takihira, Y.; Tozawa, M.; Kakubata, H.; Trang, V. T. T.; Ohata, T.; Tetsuno, K.; Maeda, T.; Khai, B. T.; Li, X. L.; Batpurev, T.

    2018-01-01

    A low background HPGe detector system was developed at CANDLES Experimental Hall for multipurpose use. Various low background techniques were employed, including hermatic shield design, radon gas suppression, and background reduction analysis. A new pulse shape discrimination (PSD) method was specially created for coaxial Ge detector. Using this PSD method, microphonics noise and background event at low energy region less than 200 keV can be rejected effectively. Monte Carlo simulation by GEANT4 was performed to acquire the detection efficiency and study the interaction of gamma-rays with detector system. For rare decay measurement, the detector was utilized to detect the nature's most stable isomer tantalum-180m (180Tam) decay. Two phases of tantalum physics run were completed with total livetime of 358.2 days, which Phase II has upgraded shield configuration. The world most stringent half-life limit of 180Tam has been successfully achieved.

  11. Half-life of each dioxin and PCB congener in the human body

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, Isamura [National Institute of Advanced Industrial Science and Technology, Tsukuba (Japan)

    2004-09-15

    It is well known that dioxin and PCB congeners accumulate in the human body. For assessing their toxicological risk, it is important to know the half-life of each congener in the human body. This study summarizes the overall half-lives of congeners in humans as reported in the literature, and compares them with the half-lives due to fecal and sebum excretions, as estimated by data on the concentrations of congeners in feces and sebum in the literature. In addition, the overall half-lives of congeners for the general Japanese population were estimated from the data on dietary intakes and concentrations in the human body reported by the municipalities.

  12. The beta(+) decay and cosmic-ray half-life of Mn-54

    Science.gov (United States)

    Dacruz, M. T. F.; Norman, E. B.; Chan, Y. D.; Garcia, A.; Larimer, R. M.; Lesko, K. T.; Stokstad, R. G.; Wietfeldt, F. E.

    1993-03-01

    We performed a search for the beta(+) branch of Mn-54 decay. As a cosmic ray, Mn-54, deprived of its atomic electrons, can decay only via beta(+) and beta(-) decay, with a half-life of the order of 106 yr. This turns Mn-54 into a suitable cosmic chronometer for the study of cosmic-ray confinement times. We searched for coincident back-to-back 511-keV gamma-rays using two germanium detectors inside a Nal(Tl) annulus. An upper limit of 2 x 10-8 was found for the beta(+) decay branch, corresponding to a lower limit of 13.7 for the log ft value.

  13. Precision measurement of the half-life of $^{109}$In in large and small lattice environments

    CERN Multimedia

    We propose to undertake high precision measurements of the half-life of $^{109}$In in large and small lattice environments to study the effect of compression on the electron capture nuclear decay rate. Such studies are of general interest having implications in many areas ranging from astrophysics to geophysics. At present, very little data is available on the change of electron capture decay rate under compression and the available data seems to indicate that the observed increase of the electron capture decay rate under compression is much greater than the predictions of the best available density functional calculations as obtained from TB-LMTO or WIEN2K codes. The proposed experiment should generate more data thus clarifying the experimental situation.

  14. Half-life distribution table of radioactive nuclei; Table de distribution des periodes des noyaux radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Gugenberger, P. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    This table allows to identify an element if its period is known. Data for this table were taken from the half-life values adopted by Hollander, PERLMAN and SEABORG (Rev. mod. Phys., 1953, 22 number 2). Moreover for each nucleus, the mass number, the charge number and the type of decay are given in the table. (author) [French] Cette table permet l'identification d'un element dont la periode est connue. Elle a ete etablie en utilisant les valeurs des periodes donnees par HOLLANDER, PERLMAN et SEABORG dans Rev. mod. Phys., 1953, 25 numero 2. On y trouve en outre, pour chaque nuclide, les caracteristiques suivantes: Z, A, modes de desintegration. (auteur)

  15. Development of a time-variable nuclear pulser for half life measurements

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Domienikan, Claudio; Carvalhaes, Roberto P. M.; Genezini, Frederico A.

    2013-01-01

    In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

  16. Development of a time-variable nuclear pulser for half life measurements

    Energy Technology Data Exchange (ETDEWEB)

    Zahn, Guilherme S.; Domienikan, Claudio; Carvalhaes, Roberto P. M.; Genezini, Frederico A. [Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP. P.O. Box 11049, Sao Paulo, 05422-970 (Brazil)

    2013-05-06

    In this work a time-variable pulser system with an exponentially-decaying pulse frequency is presented, which was developed using the low-cost, open-source Arduino microcontroler plataform. In this system, the microcontroller produces a TTL signal in the selected rate and a pulse shaper board adjusts it to be entered in an amplifier as a conventional pulser signal; both the decay constant and the initial pulse rate can be adjusted using a user-friendly control software, and the pulse amplitude can be adjusted using a potentiometer in the pulse shaper board. The pulser was tested using several combinations of initial pulse rate and decay constant, and the results show that the system is stable and reliable, and is suitable to be used in half-life measurements.

  17. Accurate γ-ray spectrometry measurements of the half-life of 92Sr

    International Nuclear Information System (INIS)

    Leconte, P.; Hudelot, J.P.; Antony, M.

    2008-01-01

    Studies of the nuclear fuel cycle require an accurate knowledge of the energy release from the decay of radioactive nuclides produced in a reactor, including precise half-life data for the short-lived radionuclides. Moreover, short-lived fission products are crucial for fission rate distribution measurements performed in low-power facilities, such as EOLE and MINERVE of CEA Cadarache [Fougeras, P., 2005. EOLE, MINERVE and MASURCA facilities and their associated neutron experimental programs. In: 13th International Conference on Nuclear Engineering, Beijing, China, 16-20 May 2005], and their nuclear decay data need to be known to high precision. For these reasons, the half-life of 92 Sr has been measured to solve a recently observed inconsistency identified with the quoted value in the main nuclear applications libraries (including JEFF3.1): T 1/2 =2.71±0.01 h [Parsa, B., Ashari, A., Goolvard, L., Nobar, Y.M., 1971. Decay scheme of 2.71 h 92 Sr. Nucl. Phys. A 175, 629-640]. An overestimation of 4.5% has been identified in this work, based on two independent methods. Specific γ-ray spectrometry measurements on activated fissile foils have been carried out, using two HPGe detectors. Influencing factors such as net area measurements of photopeaks, pulse pile-up accuracy and dead time corrections in the presence of decaying activity are discussed. A new value has been obtained by combining eight series of measurements: T 1/2 =2.594±0.006 h. The uncertainty has been reduced by a factor of two with respect to previous evaluations. This measured value also shows good agreement with the most recent studies of T 1/2 =2.627±0.009 h [Nir-El, Y., 2003. Private Communications. Soreq Research Centre, Yavne, Israel

  18. Biological half-life of iodine in adults with intact thyroid function and in athyreotic persons

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, G.H.; Hauck, B.M.; Chamberlain, M.J

    2002-07-01

    A joint project between the Human Monitoring Laboratory (HML) and the Ottawa Hospital has measured the retention of {sup 131}I in patients who have received the radioiodine diagnostically. Thirty-nine subjects with intact thyroid glands and nine athyreotic subjects were measured in the HML's whole-body/thyroid counter to determine the retention of {sup 131}I following its medical administration. The average biological half-life of {sup 131}I in 26 euthyroid subjects was found to be 66.1{+-}6.3 days which may be statistically significantly lower than the ICRP recommended value of 80 days. Nine hyperthyroid patients had a mean biological half-life of 38.2{+-}8.6 days and in three hypothyroid patients the corresponding value was 29.3{+-}8.8 days. Thyroid {sup 131}I uptake was measured in a conventional clinical fashion at the Ottawa Hospital Civic campus 24 h after oral administration of the radioiodine using a collimated thick sodium iodide detector placed over the neck arteriorly. Measured values were 0.144{+-}0.009, 0.314{+-}0.035 and 0.045{+-}0.010 of the administered dose in euthyroid, hyperthyroid and hypothyroid patients respectively. The euthyroid range at the hospital is 0.06-0.22. Uptake was significantly lower for the euthyroid group than the ICRP value of 0.3. The radioiodine retention in athyreotic subjects followed a two compartment model with biological half-lives of 1.0{+-}0.2 days and 18.4{+-}1.1. days. (author)

  19. Presynaptic Muscarinic Acetylcholine Receptors and TrkB Receptor Cooperate in the Elimination of Redundant Motor Nerve Terminals during Development.

    Science.gov (United States)

    Nadal, Laura; Garcia, Neus; Hurtado, Erica; Simó, Anna; Tomàs, Marta; Lanuza, Maria A; Cilleros, Victor; Tomàs, Josep

    2017-01-01

    The development of the nervous system involves the overproduction of synapses but connectivity is refined by Hebbian activity-dependent axonal competition. The newborn skeletal muscle fibers are polyinnervated but, at the end of the competition process, some days later, become innervated by a single axon. We used quantitative confocal imaging of the autofluorescent axons from transgenic B6.Cg-Tg (Thy1-YFP)16 Jrs/J mice to investigate the possible cooperation of the muscarinic autoreceptors (mAChR, M 1 -, M 2 - and M 4 -subtypes) and the tyrosine kinase B (TrkB) receptor in the control of axonal elimination after the mice Levator auris longus (LAL) muscle had been exposed to several selective antagonist of the corresponding receptor pathways in vivo . Our previous results show that M 1 , M 2 and TrkB signaling individually increase axonal loss rate around P9. Here we show that although the M 1 and TrkB receptors cooperate and add their respective individual effects to increase axonal elimination rate even more, the effect of the M 2 receptor is largely independent of both M 1 and TrkB receptors. Thus both, cooperative and non-cooperative signaling mechanisms contribute to developmental synapse elimination.

  20. Extending the half-life of a fab fragment through generation of a humanized anti-human serum albumin Fv domain: An investigation into the correlation between affinity and serum half-life.

    Science.gov (United States)

    Adams, Ralph; Griffin, Laura; Compson, Joanne E; Jairaj, Mark; Baker, Terry; Ceska, Tom; West, Shauna; Zaccheo, Oliver; Davé, Emma; Lawson, Alastair Dg; Humphreys, David P; Heywood, Sam

    2016-10-01

    We generated an anti-albumin antibody, CA645, to link its Fv domain to an antigen-binding fragment (Fab), thereby extending the serum half-life of the Fab. CA645 was demonstrated to bind human, cynomolgus, and mouse serum albumin with similar affinity (1-7 nM), and to bind human serum albumin (HSA) when it is in complex with common known ligands. Importantly for half-life extension, CA645 binds HSA with similar affinity within the physiologically relevant range of pH 5.0 - pH 7.4, and does not have a deleterious effect on the binding of HSA to neonatal Fc receptor (FcRn). A crystal structure of humanized CA645 Fab in complex with HSA was solved and showed that CA645 Fab binds to domain II of HSA. Superimposition with the crystal structure of FcRn bound to HSA confirmed that CA645 does not block HSA binding to FcRn. In mice, the serum half-life of humanized CA645 Fab is 84.2 h. This is a significant extension in comparison with Fab variant. The Fab-HSA structure was used to design a series of mutants with reduced affinity to investigate the correlation between the affinity for albumin and serum half-life. Reduction in the affinity for MSA by 144-fold from 2.2 nM to 316 nM had no effect on serum half-life. Strikingly, despite a reduction in affinity to 62 µM, an extension in serum half-life of 26.4 h was still obtained. CA645 Fab and the CA645 Fab-HSA complex have been deposited in the Protein Data Bank (PDB) with accession codes, 5FUZ and 5FUO, respectively.

  1. Ecological half-life of 137Cs in plants associated with a contaminated stream

    International Nuclear Information System (INIS)

    Peles, John D.; Smith, Michael H.; Lehr Brisbin, I.

    2002-01-01

    Ecological half-life (T e ) is a useful measure for studying the long-term decline of contaminants, such as radionuclides, in natural systems. The current investigation determined levels of radiocesium ( 137 Cs) in two aquatic (Polygonum punctatum, Sagittaria latifolia) and three terrestrial (Alnus serrulata, Myrica cerifera, Salix nigra) plant species from a contaminated stream and floodplain on the U.S. Department of Energy's Savannah River Site. Current 137 Cs levels in plants were used in conjunction with historical data to determine T e of 137 Cs in each species. Median concentrations of 137 Cs were highest in S. latifolia (0.84 Bq g -1 ) and lowest in M. cerifera (0.10 Bq g -1 ). T e 's ranged from 4.85 yr in M. cerifera to 8.35 yr in S. nigra, both terrestrial species. T e 's for all aquatic (6.30 yr) and all terrestrial (5.87) species combined were very similar. The T e 's of the two aquatic primary producers (P. punctatum and S. latifolia) in the Steel Creek ecosystem were somewhat longer than T e values previously reported for some consumers from this ecosystem

  2. Prediction of thyroidal 131I effective half-life in patients with Graves' disease.

    Science.gov (United States)

    Zhang, Ruiguo; Zhang, Guizhi; Wang, Renfei; Tan, Jian; He, Yajing; Meng, Zhaowei

    2017-10-06

    Calculation of effective thyroidal half-life (Teff) of iodine-131( 131 I) is cumbersome and tedious. The aim of this study was to investigate factors that could be used to predict Teff and to develop a Teff prediction model in Graves' disease patients. A total of 256 patients with GD were involved in this study. We investigated the influences of age, gender, disease duration, thyroid weight, antithyroid drugs, antithyroid drugs discontinuation period (ADP), thyroid function indexes, thyroid autoantibodies, thyroid-stimulating hormone receptor antibody (TRAb) level and radioactive iodine uptake (RAIU) values before 131 I therapy on Teff, applying univariate and multivariate analyses. Teff correlated negatively with thyroid peroxidase antibody, TRAb and thyroid weight, as well as positively with 24-hour, 48-hour, and 72-hour RAIU. Additionally, a longer ADP (especially≥ 14d) or without antithyroid drugs before 131 I therapy led to a longer Teff. Stepwise multiple linear regression analysis showed that 24-hour and 72-hour RAIU were statistically significant predictors of Teff ( P Graves' disease, with high prediction accuracy.

  3. Micooprecessor controlled facility for I.N.A.A. using short half life nuclides

    International Nuclear Information System (INIS)

    Bode, P.; Korthoven, P.J.M.; Bruin, M. de

    1986-01-01

    At IRI a new, fully atomated facility for short half life INAA is being developed and installed at the Institute 2 MW reactor. The fast rabbit transfer system is constructed only of plastic and carbonfiber parts, so that rabbit contamination is minimized. This system is automated in such a way that it can operate safely without direct supervision; the sequence of irradiations and measurements is optimized by a computer-program for a given set of samples and analysis procedures. The rabbit system is controlled by an Apple IIe-computer connected to the central PDP 11/44 system of the Radiochemistry department. For a given set of samples and required analysis procedures (irradiation-,decay-, and measurement times) the central computer calculates an optimal sequence of individual actions (transfer from and to the reactor, sample storage of detector) to be carried out by the system. This sequence is loaded into the Apple-computer as a series of commands together with timing information. Actual control of the procedure occurs through the peripheral computer, which makes the system independent of delays or break-downs of the central multi-user computer system. Hardware, software and operating characteristics of the fast rabbit system will be discussed. (author)

  4. Kinetic modeling and half life study on bioremediation of crude oil dispersed by Corexit 9500

    International Nuclear Information System (INIS)

    Zahed, Mohammad Ali; Aziz, Hamidi Abdul; Isa, Mohamed Hasnain; Mohajeri, Leila; Mohajeri, Soraya; Kutty, Shamsul Rahman Mohamed

    2011-01-01

    Hydrocarbon pollution in marine ecosystems occurs mainly by accidental oil spills, deliberate discharge of ballast waters from oil tankers and bilge waste discharges; causing site pollution and serious adverse effects on aquatic environments as well as human health. A large number of petroleum hydrocarbons are biodegradable, thus bioremediation has become an important method for the restoration of oil polluted areas. In this research, a series of natural attenuation, crude oil (CO) and dispersed crude oil (DCO) bioremediation experiments of artificially crude oil contaminated seawater was carried out. Bacterial consortiums were identified as Acinetobacter, Alcaligenes, Bacillus, Pseudomonas and Vibrio. First order kinetics described the biodegradation of crude oil. Under abiotic conditions, oil removal was 19.9% while a maximum of 31.8% total petroleum hydrocarbons (TPH) removal was obtained in natural attenuation experiment. All DCO bioreactors demonstrated higher and faster removal than CO bioreactors. Half life times were 28, 32, 38 and 58 days for DCO and 31, 40, 50 and 75 days for CO with oil concentrations of 100, 500, 1000 and 2000 mg/L, respectively. The effectiveness of Corexit 9500 dispersant was monitored in the 45 day study; the results indicated that it improved the crude oil biodegradation rate.

  5. Goiania radiation accident: 30 years - a half-life for a whole life..

    International Nuclear Information System (INIS)

    Reis, R.G.; Lucena, E.A.; Arantes, R.R.; Silva, A.A.; Reis, A.A.

    2017-01-01

    The radiological accident in Goiânia, Brazil, considered the largest urban radiological accident in the world, generated several publications in the technical area that are widely disseminated in the scientific literature, given the importance of the lessons learned. However, in a simple conversation with people who worked on that accident, it is noted that many reports have not been recorded. In this year in which 30 years of the event is completed, it will be of great value to record personal testimonies that are not in technical or scientific books. And what can we tell after a half-life that lasted for a lifetime? The lived stories, the situations, the improvisations, the way to solve, the overcoming, the human side, the emotions, happy or sad, short or long, funny or not. The objective of this work is to preserve, maintain and divulge reports and situations experienced by people who worked on the radiological accident with Cs-137 in Goiânia. Audio or video recordings about experiences lived in Goiânia by people who worked in that emergency situation were carried out. The reports are free and the form of registration is always at the discretion of the narrator. Storing records allows to preserve, maintain, and disclose the accident to other generations

  6. $\\beta$-decay half-life of $^{70}$Kr a bridge nuclide for the rp-process beyond A = 70

    CERN Document Server

    Oinonen, M; Jokinen, A; Baumann, P; Didierjean, François; Huck, A; Knipper, A; Ramdhane, M; Walter, G; Van Duppen, P; Huyse, M; Marguier, G; Novikov, Yu N; Popov, A; Seliverstov, D M; Schatz, H

    2000-01-01

    The $\\beta$-decay half-life of $^{70}$Kr has been measured for the first time at the ISOLDE PSB Facility at CERN. Mass separated $^{70}$Kr ions were produced by 1 GeV proton induced spallation reactions in a Nb foil. The measured half-life is 57(21) ms. This value is consistent with the half-life calculated assuming a pure Fermi decay, but is clearly lower than the value used in a recent rp-process reaction flow calculation. The result shows that the reaction flow via two-proton-capture of $^{68}$Se is 2.5 times faster than previously calculated assuming an astrophysical temperature of 1.5 GK and a density of 10$^{6}$g/cm$^{3}$.

  7. Towards a measurement of the half-life of {sup 60}Fe for stellar and early Solar System models

    Energy Technology Data Exchange (ETDEWEB)

    Ostdiek, K.; Anderson, T. [University of Notre Dame, Notre Dame, IN 46556 (United States); Bauder, W. [University of Notre Dame, Notre Dame, IN 46556 (United States); Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States); Bowers, M.; Collon, P. [University of Notre Dame, Notre Dame, IN 46556 (United States); Dressler, R. [Paul Scherrer Institute – Laboratory for Radiochemistry and Environmental Chemistry, 5232 Villigen (Switzerland); Greene, J. [Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States); Kutschera, W. [Vienna Environmental Research Accelerator Laboratory, Waehringer Strasse 17, 1090 Vienna (Austria); Lu, W. [University of Notre Dame, Notre Dame, IN 46556 (United States); Paul, M. [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Robertson, D. [University of Notre Dame, Notre Dame, IN 46556 (United States); Schumann, D. [Paul Scherrer Institute – Laboratory for Radiochemistry and Environmental Chemistry, 5232 Villigen (Switzerland); Skulski, M. [University of Notre Dame, Notre Dame, IN 46556 (United States); Wallner, A. [The Australian National University, Canberra, ACT 0200 (Australia)

    2015-10-15

    Radioisotopes, produced in stars and ejected into the Interstellar Medium, are important for constraining stellar and early Solar System (ESS) models. In particular, the half-life of the radioisotope, {sup 60}Fe, can have an impact on calculations for the timing for ESS events, the distance to nearby Supernovae, and the brightness of individual, non-steady-state {sup 60}Fe gamma ray sources in the Galaxy. A half-life measurement has been undertaken at the University of Notre Dame and measurements of the {sup 60}Fe/{sup 56}Fe concentration of our samples using Accelerator Mass Spectrometry has begun. This result will be coupled with an activity measurement of the isomeric decay in {sup 60}Co, which is the decay product of {sup 60}Fe. Preliminary half-life estimates of (2.53 ± 0.24) × 10{sup 6} years seem to confirm the recent measurement by Rugel et al. (2009).

  8. New evaluation of alpha decay half-life of 190Pt isotope for the Pt-Os dating system

    International Nuclear Information System (INIS)

    Tavares, O.A.P.; Medeiros, E.L.; Terranova, M.L.

    2005-08-01

    A semiempirical model based on the quantum mechanical tunnelling mechanism of alpha emission from nuclei has been used to evaluate the half-life of the Pt isotopes. For the important naturally occurring 190 Pt isotope, the radiogenic parent in the 190 Pt → 186 Os dating system, the model yielded a half-life value of (3.7± 0.3) versus 10 11 y. This is comparable to (3.2±0.1) versus 10 11 y which was obtained in the last direct counting experiment to measure the alpha activity of 190 Pt (Tavares and Terranova, Rad. Measurem. 27 (1997) 19). A literature survey of available alpha decay half-life values for 190 Pt isotope is also reported. The significant discrepancies found between data obtained by direct counting, indirect geological methods and different calculation models are analysed and discussed. (author)

  9. High-Precision Half-Life Measurements for the Superallowed Fermi β+ Emitters 14O and 18Ne

    Science.gov (United States)

    Laffoley, A. T.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bender, P. C.; Bidaman, H.; Bildstein, V.; Blank, B.; Bouzomita, H.; Cross, D. S.; Deng, G.; Diaz Varela, A.; Dunlop, M. R.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P.; Giovinazzo, J.; Grinyer, G. F.; Grinyer, J.; Hadinia, B.; Jamieson, D. S.; Jigmeddorj, B.; Ketelhut, S.; Kisliuk, D.; Leach, K. G.; Leslie, J. R.; MacLean, A.; Miller, D.; Mills, B.; Moukaddam, M.; Radich, A. J.; Rajabali, M. M.; Rand, E. T.; Svensson, C. E.; Tardiff, E.; Thomas, J. C.; Turko, J.; Voss, P.; Unsworth, C.

    High-precision half-life measurements, at the level of ±0.04%, for the superallowed Fermi emitters 14O and 18Ne have been performed at TRIUMF's Isotope Separator and Accelerator facility. Using 3 independent detector systems, a gas-proportional counter, a fast plastic scintillator, and a high-purity germanium array, a series of direct β and γ counting measurements were performed for each of the isotopes. In the case of 14O, these measurements were made to help resolve an existing discrepancy between detection methods, whereas for 18Ne the half-life precision has been improved in anticipation of forthcoming high-precision branching ratio measurements.

  10. High-precision half-life and branching-ratio measurements for superallowed Fermi β+ emitters at TRIUMF - ISAC

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Grinyer, G. F.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Blank, B.; Bouzomita, H.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Demand, G.; Diaz Varela, A.; Djongolov, M.; Ettenauer, S.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Glister, J.; Green, K. L.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Tardiff, E. R.; Thomas, J. C.; Towner, I. S.; Triambak, S.; Unsworth, C.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2014-03-01

    A program of high-precision half-life and branching-ratio measurements for superallowed Fermi β emitters is being carried out at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. Recent half-life measurements for the superallowed decays of 14O, 18Ne, and 26Alm, as well as branching-ratio measurements for 26Alm and 74Rb are reported. These results provide demanding tests of the Standard Model and the theoretical isospin symmetry breaking (ISB) corrections in superallowed Fermi β decays.

  11. Real-World Analysis of Dispensed IUs of Coagulation Factor IX and Resultant Expenditures in Hemophilia B Patients Receiving Standard Half-life Versus Extended Half-life Products and Those Switching from Standard Half-life to Extended Half-life Products.

    Science.gov (United States)

    Tortella, Bartholomew J; Alvir, José; McDonald, Margaret; Spurden, Dean; Fogarty, Patrick F; Chhabra, Amit; Pleil, Andreas M

    2018-01-24

    Hemophilia B requires replacement therapy with factor IX (FIX) coagulation products to treat and prevent bleeding episodes. A recently introduced extended half-life (EHL) recombinant FIX replacement product provided the opportunity to compare the amount of dispensed factor and expenditures for EHL treatment compared with a standard half-life (SHL) product. To determine factor international units (IUs) dispensed and expenditures associated with switching from nonacog alfa, the most commonly used SHL replacement product, to eftrenonacog alfa, an EHL FIX replacement product. Two U.S. claims databases were analyzed. A large national specialty pharmacy dispensation claims database was used to identify the number of IUs dispensed and monthly charges for all patients with hemophilia B from April 2015 to June 2016. Truven Health MarketScan Research Databases (January 2010-July 2016) were used to identify IUs and expenditures for patients with claims data for at least 3 months before and after switching from the SHL to the EHL product. Medians for IUs and expenditures are presented to accommodate for skewness of data distribution. The national specialty pharmacy database analysis included 296 patients with moderate or severe hemophilia B (233 on SHL; 94 on EHL). Median monthly factor dispensed was 11% lower (2,142 IU) in the EHL versus SHL cohort over the study period, while individual monthly reductions ranged from 32% to 47% (9,838 IU to 16,514 IU). Using the wholesale acquisition cost, the median per-patient monthly factor expenditures over the 15-month study period were 94% higher ($23,005) for the EHL than for the SHL product. Individual median monthly expenditure differences ranged from 15% ($6,562) to 49% ($19,624). In the Truven database, 14 patients switched from the SHL to the EHL product. The amount of factor dispensed was variable; in the 1-year period before and after the switch from the SHL to the EHL product, mean IUs dispensed decreased by 3,005 IU, while

  12. Biological Half-Life Measurements of Radioactive Strontium in Hormonal-Resistant Prostate Cancer Patients

    International Nuclear Information System (INIS)

    Haquin, G.; Riemer, T.; Kaniun, N.; Datz, H.; Yungreiss, Z.; Vexler, A.; Ben-Yosef, R.; Pelled, O.; German, U.; Marko, R.; Teshuva, A.; Kol, R.

    2004-01-01

    Therapy for metastatic bone pain in Hormonal-Resistant Prostate Cancer (HRPC) patients is performed by administering systemic radioisotope therapy [1]. The beta radiation emitted by the radioactive strontium 89 Sr [T 1/2 =50.5 d, E β (max)=1.49 MeV], an adequate radionuclide for this therapy procedure, irradiates the metastatic cells in the bone, producing the desired palliative effect. The beta disintegration of 89 Sr is followed by a low abundance (0.00945%) gamma ray with energy of 909 keV. The commercially available 89 Sr is in the form of Sr Cl and contains an impurity of less than 0.5% of 85 Sr [T 1/2 =64.8 d] ,which decays by electron capture, emitting gamma rays at 511 keV (95.71%). The radiation dose to the metastatic cells due to the gamma rays is negligible compared to the dose given by the beta radiation, assuming that the 89 Sr is concentrated at the metastatic bony lesions. Accurate information about retention and excretion of Sr in the patient's body will contribute to better evaluate the effectiveness of the treatment. he effective half-life of 89 Sr can be calculated either from Whole Body Counting (WBC) measurements or by measuring 85 Sr and/or 89 Sr in urine/blood. WBC measurements, using collimated HPGe detectors, allow the follow-up of 89 Sr and 85 Sr at different sites in the skeletal bones of the patient. Biological half-lives of Sr in different body sections measured by WBC and the correlation with excretion-rate-based biological half-lives are presented

  13. Carboxyhemoglobin half-life during hyperbaric oxygen in a patient with lung dysfunction: a case report.

    Science.gov (United States)

    Weaver, Lindell K; Deru, Kayla

    2017-01-01

    The carboxyhemoglobin half-life (COHb t1/2) during hyperbaric oxygen (HBO₂) is often quoted as 23 minutes, derived from the average of two adult male volunteers breathing HBO₂ at 3 atmospheres absolute (ATA). However, the mean COHb t1/2 of 12 male volunteer smokers was 26.3 minutes at 1.58 ATA and in 12 non-intubated carbon monoxide (CO) poisoned patients treated at 3 ATA, was 43 minutes. An 81-year old male, poisoned by an improperly ventilated natural gas heater, was intubated for coma, then treated with HBO₂. His PaO₂/FiO₂ = 283 from aspiration. His initial COHb was 34.4%, and 18 minutes before HBO₂, 5.9%. After a compression interval of 17 minutes, the COHb measured after 22 minutes at 3 ATA was 3.3%. By exponential decay, his COHb t1/2 before HBO₂ was 95 minutes. We estimate the range for COHb t1/2 during compression as 62-81 minutes and for the 3-ATA interval, 58 to 49 minutes, respectively. The mid-point estimate of COHb t1/2 at 3 ATA was 53 minutes. The COHb t1/2 we calculated is greater than previously reported, but longer in our patient possibly because of concomitant respiratory failure, lung dysfunction, and mechanical ventilation. The often-cited COHb t1/2 of 23 minutes, likely underestimates the actual COHb t1/2 in CO-poisoned patients, especially those with cardiopulmonary dysfunction.

  14. Biological half-life of bromide in the rat depends primarily on the magnitude of sodium intake

    Czech Academy of Sciences Publication Activity Database

    Pavelka, Stanislav; Babický, Arnošt; Vobecký, Miloslav

    2005-01-01

    Roč. 54, č. 6 (2005), s. 639-644 ISSN 0862-8408 Institutional research plan: CEZ:AV0Z50110509 Keywords : biological half-life * bromide * sodium Subject RIV: ED - Physiology Impact factor: 1.806, year: 2005

  15. Ubiquitin-fusion as a strategy to modulate protein half-life: A3G antiviral activity revisited

    International Nuclear Information System (INIS)

    Cadima-Couto, Iris; Freitas-Vieira, Acilino; Nowarski, Roni; Britan-Rosich, Elena; Kotler, Moshe; Goncalves, Joao

    2009-01-01

    The human APOBEC3G (A3G) is a potent inhibitor of HIV-1 replication and its activity is suppressed by HIV-1 virion infectivity factor (Vif). Vif neutralizes A3G mainly by inducing its degradation in the proteasome and blocking its incorporation into HIV-1 virions. Assessing the time needed for A3G incorporation into virions is, therefore, important to determine how quickly Vif must act to induce its degradation. We show that modelling the intracellular half-life of A3G can induce its Vif-independent targeting to the ubiquitin-proteasome system. By using various amino acids (X) in a cleavable ubiquitin-X-A3G fusion, we demonstrate that the half-life (t1/2) of X-A3G can be manipulated. We show that A3G molecules with a half-life of 13 min are incorporated into virions, whereas those with a half-life shorter than 5 min were not. The amount of X-A3G incorporated into virions increases from 13 min (Phe-A3G) to 85 min (Asn-A3G) and remains constant after this time period. Interestingly, despite the presence of similar levels of Arg-A3G (t1/2 = 28 min) and Asp-A3G (t1/2 = 65 min) into HIV-1 Δvif virions, inhibition of viral infectivity was only evident in the presence of A3G proteins with a longer half-life (t1/2 ≥ 65 min).

  16. Effective Half-Life of Caesium-137 in Various Environmental Media at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Paller, M. H.; Jannik, G. T.; Baker, R. A.

    2014-05-01

    During the operational history of the Savannah River Site (SRS), many different radionuclides have been released from site facilities into the SRS environment. However, only a relatively small number of pathways, most importantly 137Cs in fish and deer, have contributed significantly to doses and risks to the public. The “effective” half-lives (Te) of 137Cs (which include both physical decay and environmental dispersion) in Savannah River floodplain soil and vegetation and in fish and white-tailed deer from the SRS were estimated using long-term monitoring data. For 1974–2011, the Tes of 137Cs in Savannah River floodplain soil and vegetation were 17.0 years (95% CI = 14.2–19.9) and 13.4 years (95% CI = 10.8–16.0), respectively. These Tes were greater than in a previous study that used data collected only through 2005 as a likely result of changes in the flood regime of the Savannah River. Field analyses of 137Cs concentrations in deer collected during yearly controlled hunts at the SRS indicated an overall Te of 15.9 years (95% CI = 12.3–19.6) for 1965–2011; however, the Te for 1990–2011 was significantly shorter (11.8 years, 95% CI = 4.8–18.8) due to an increase in the rate of 137Cs removal. The shortest Tes were for fish in SRS streams and the Savannah River (3.5–9.0 years), where dilution and dispersal resulted in rapid 137Cs removal. Long-term data show that Tes are significantly shorter than the physical half-life of 137Cs in the SRS environment but that they can change over time. Therefore, it is desirable have a long period of record for calculating Tes and risky to extrapolate Tes beyond this period unless the processes governing 137Cs removal are clearly understood.

  17. Improved half-life determination and β-delayed γ-ray spectroscopy for 18Ne decay

    Science.gov (United States)

    Grinyer, G. F.; Ball, G. C.; Bouzomita, H.; Ettenauer, S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Green, K. L.; Hackman, G.; Leslie, J. R.; Pearson, C. J.; Rand, E. T.; Sumithrarachchi, C. S.; Svensson, C. E.; Thomas, J. C.; Triambak, S.; Williams, S. J.

    2013-04-01

    The half-life of the superallowed Fermi β+ emitter 18Ne has been determined to ±0.07% precision by counting 1042 keV delayed γ rays that follow approximately 8% of all β decays. The deduced half-life, T1/2=1.6648(11) s, includes a 0.7% correction that accounts for systematic losses associated with rate-dependent detector pulse pileup that was determined using a recently developed γ-ray photopeak-counting technique. This result is a factor of two times more precise than, and in excellent agreement with, a previous lower-statistics measurement that employed the same experimental setup. High-resolution β-delayed γ-ray spectroscopy results for the relative γ-ray intensities and β-decay branching ratios to excited states in the daughter 18F are also presented.

  18. Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

    Energy Technology Data Exchange (ETDEWEB)

    Argyriades, J. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France); Arnold, R. [IPHC, Universite de Strasbourg, CNRS/IN2P3, F-67037 Strasbourg (France); Augier, C. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France); Baker, J. [INL, Idaho National Laboratory, 83415 Idaho Falls (United States); Barabash, A.S. [ITEP, Institute of Theoretical and Experimental Physics, 117259 Moscow (Russian Federation); Basharina-Freshville, A. [University College London, WC1E 6BT London (United Kingdom); Bongrand, M. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France); Broudin-Bay, G. [Universite Bordeaux, CENBG, UMR 5797, F-33175 Gradignan (France); CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR5797, F-33175 Gradignan (France); Brudanin, V. [JINR, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Caffrey, A.J. [INL, Idaho National Laboratory, 83415 Idaho Falls (United States); Chapon, A. [LPC, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Chauveau, E. [Universite Bordeaux, CENBG, UMR 5797, F-33175 Gradignan (France); CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR5797, F-33175 Gradignan (France); Daraktchieva, Z. [University College London, WC1E 6BT London (United Kingdom); Durand, D. [LPC, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Egorov, V. [JINR, Joint Institute for Nuclear Research, 141980 Dubna (Russian Federation); Fatemi-Ghomi, N. [University of Manchester, M13 9PL Manchester (United Kingdom); Flack, R. [University College London, WC1E 6BT London (United Kingdom); Guillon, B. [LPC, ENSICAEN, Universite de Caen, CNRS/IN2P3, F-14032 Caen (France); Hubert, Ph. [Universite Bordeaux, CENBG, UMR 5797, F-33175 Gradignan (France); CNRS/IN2P3, Centre d' Etudes Nucleaires de Bordeaux Gradignan, UMR5797, F-33175 Gradignan (France); Jullian, S. [LAL, Universite Paris-Sud 11, CNRS/IN2P3, F-91405 Orsay (France)

    2010-12-08

    Using 9.4 g of {sup 96}Zr isotope and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg y, the obtained 2{nu}{beta}{beta} decay half-life measurement is T{sub 1/2}{sup 2{nu}=}[2.35{+-}0.14(stat){+-}0.16(syst)]x10{sup 19} yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2{nu} nuclear matrix element is extracted using the measured 2{nu}{beta}{beta} half-life and is M{sup 2{nu}=}0.049{+-}0.002. Constraints on 0{nu}{beta}{beta} decay have also been set.

  19. Near-optimum procedure for half-life measurement by high-resolution gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Parker, J.L.

    1989-01-01

    A near-optimum procedure for using high-resolution γ-ray spectrometry to measure the half-lives of appropriate γ-ray- emitting-nuclides is presented. Among the important points of the procedure are the employment of the reference source method for implicit correction of pileup and deadtime losses; the use of full-energy peak-area ratios as the fundamental measured quantities; and continuous, high-rate data acquisition to obtain good results in a fraction of a half-life if desired. Equations are given for estimating the precision of the computed half-lives in terms of total measurement time, number of spectral acquisitions, and the precision of peak-area ratios. Results of 169 Yb half-life measurements are given as an example of the procedure's application. 3 refs., 2 tabs

  20. Usefulness of analytical CEA doubling time and half-life time for overlooked synchronous metastases in colorectal carcinoma.

    Science.gov (United States)

    Ito, Katsuki; Hibi, Kenji; Ando, Hideyuki; Hidemura, Kazuhiko; Yamazaki, Taiji; Akiyama, Seiji; Nakao, Akimasa

    2002-02-01

    Measurement of carcinoembryonic antigen (CEA) has been widely applied to detect recurrence, especially of colorectal carcinoma. The validity however, is still controversial. We investigated serial changes in CEA values to calculate whether the CEA doubling time and half-life time could predict metastatic progression or prognosis in colorectal carcinoma. Pre- and post-operative serial serum CEA contents were determined in 22 cases of colorectal cancer with or without metastasis. CEA values were determined by enzyme immunoassay (EIA). Patients were assigned depending upon survival time (within vs. more than 18 months after primary resection) for assessment of CEA doubling time. From the gradient of the semi-logarithmic CEA graph, the preoperative doubling time was calculated and the postoperative half-life time was estimated according to the diagnosis of metastases within 2 years after primary resection [metastasis (+) or (-)]. In spite of the effect of curative re-operation of metastatic lesions or of postoperative adjuvant chemotherapy, the CEA doubling time of the groups showed a relation with prognosis (p = 0.045, Student's t-test) when the patients were divided into >18 and time. The CEA half-life time of the groups without overlooked metastases was statistically longer than those with (mean +/- SD 8.01 +/- 2.07 and 4.33 +/- 1.11, respectively, p Clearance (k) showed a significant difference between the groups (p time appeared to be a less independent prognostic factor, whereas prolongation of the CEA half-life time might potentially suggest the existence of overlooked synchronous metastases from colorectal carcinoma.

  1. Absorption and biological half-life in humans of intrinsic and extrinsic 54Mn tracers from foods of plant origin

    International Nuclear Information System (INIS)

    Johnson, P.E.; Lykken, G.I.; Korynta, E.D.

    1991-01-01

    Absorption and biological half-life of 54 Mn were measured in adult men and women fed foods labeled intrinsically or extrinsically with 54 Mn. Each subject consumed a series of three test meals consisting of a food labeled intrinsically, a food labeled extrinsically or MnCl 2 (control) served in random order. The foods tested were lettuce, spinach, wheat and sunflower seeds. Lettuce meals and their controls contained 9.65 mumol Mn; other meals contained 22.50 mumol Mn. In addition to the test food or MnCl 2 , each meal consisted of vegetable oil (5 g), salt (NaCl, 0.15 g) and crackers (10 g), which provided 0.55 mumol Mn. There were no differences in percentage of Mn absorption or biological half-life of 54 Mn for any of the intrinsically/extrinsically labeled food pairs. Absorption of 54 Mn from MnCl 2 (8.90%) was greater than from lettuce (5.20%), spinach (3.81%), wheat (2.16%) or sunflower seeds (1.71%), but the biological half-life did not vary with the source of Mn. Absorption of 54 Mn from lettuce was significantly (P less than 0.05) greater than from wheat or sunflower seeds. Although the Mn dose in the test meal was less for lettuce than for the other foods, there was no difference in Mn absorption from MnCl 2 between the subjects fed lettuce and subjects fed other foods. There was no correlation of either 54 Mn absorption or biological half-life with whole blood or plasma Mn

  2. On the way to high-power linear proton accelerator for the long half-life radionuclides transmutation

    International Nuclear Information System (INIS)

    Batskikh, G.I.; Lupandin, O.S.; Murin, B.P.; Fedotov, A.P.

    1991-01-01

    The concept of continuous mode high-power linear proton accelerator with 1.5 GeV energy, 0.3 A current for the long half-life nuclides transmutation into the short ones (waste of atomic power plants (APP)) is proposed. The accelerator design main principles, scheme and parameters are presented. The accent is made on the accelerator efficiency, reliability and radiation purity. (author)

  3. On the statistical evaluation of inconsistent measurement results illustrated on the example of the 90Sr half-life

    International Nuclear Information System (INIS)

    Zijp, W.L.

    1985-12-01

    The problem how to make an objective evaluation of inconsistent numerical observations made by different authors or laboratories on the same physical quantity is dealt with. The problem is treated in a practical way in the light of the example on the half-life of 90 Sr, and it is to some extent a response to a document by Gray (1985) on the same topic

  4. Influence of antithyroid medication on effective half-life and uptake of 131 I following radioiodine therapy

    International Nuclear Information System (INIS)

    Moka, D.; Voth, E.; Schicha, H.

    1997-01-01

    Aim: A radioiodine therapy (RIT) in thyrotoxic patients receiving antithyroid drugs (ATD) leads in comparison to nonpretreated patients either to higher therapeutic doses or to higher treatment failure rates. Aim of this study was to optimize the effect of RIT in patients pretreated with ATD. Methods: Therefore, the influence of ATD was assessed in 109 patients with shortened effective half-life of 131 I. RIT was performed under stationary conditions. Radioiodine activity of the thyroid gland was stopped three days after RIT. The patients antithyroid medication was stopped three days after RIT. The progress of the first RIT and of a second radioiodine application, which still was necessary in 29 patients, was compared to 32 patients receiving ATD, continuously. Results: Values of effective half-life for 131 I rose significantly from 3.2±0.2 to 5.7±0.2 days (Graves' disease: 3.4 to 5.7 days; toxic goiters' disease: Multifocal autonomy 3.2 to 6.2 days; unifocal autonomy 2.5 auf 5.0 days) 2-3 days after stopping ATD. There was an increase of the 131 I-uptake of a second RIT decreased significantly in patients receiving ATD, continuously. Conclusion: Effective half-life and uptake of 131 I was affected significantly by ATD. The stop taking of ATD after RIT is useful to improve an apparent insufficient RIT in thyrotoxic patients receiving ATD. (orig.) [de

  5. Thirty years after Chernobyl: Long-term determination of 137Cs effective half-life in the lichen Stereocaulon vesuvianum.

    Science.gov (United States)

    Savino, F; Pugliese, M; Quarto, M; Adamo, P; Loffredo, F; De Cicco, F; Roca, V

    2017-06-01

    It has been widely shown that nuclear fallout includes substances, which accumulate in organisms such as crustaceans, fish, mushrooms and lichens, helping to evaluate the activity concentration of contaminants accumulated on a long time. In this context, radiocaesium deposited in soil following the Chernobyl accident on 26 April 1986 is known to have remained persistently available for plant uptake in many areas of Europe. Studies on the lichen Stereocaulon vesuvianum show the plant's high capacity to retain radionuclides from the substrate and the air. After the Chernobyl accident, starting from September 1986, at the Radioactivity Laboratory (LaRa) of the University of Naples Federico II, four monitoring campaigns to evaluate the activity concentration of four isotopes of the two elements caesium and ruthenium ( 134 Cs, 137 Cs, 103 Ru and 106 Ru) were carried out until 1999. This study allowed the effective half-life of 134 Cs and 137 Cs to be estimated. Twenty-eight years after the accident, in December 2014, a further sampling was carried out; only 137 Cs was revealed beyond the detection limits, measuring activity concentrations ranging from 20 to 40 Bq/kg, while the other radionuclides were no longer observed due to their shorter half-life. The last sampling allowed more precise determination of the effective half-life of 137 Cs (6.2 ± 0.1 year), due to the larger dataset on a large time period. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

    International Nuclear Information System (INIS)

    Oliveira, P. A.; Santos, J. A. M.

    2014-01-01

    Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as 99m Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of 99m Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using 99m Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for 99m Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides

  7. Advances in therapeutic Fc engineering - modulation of IgG associated effector functions and serum half-life

    Directory of Open Access Journals (Sweden)

    Abhishek Saxena

    2016-12-01

    Full Text Available Today monoclonal immunoglobulin gamma (IgG antibodies have become a major option in cancer therapy especially for the patients with advanced or metastatic cancers. Efficacy of monoclonal antibodies (mAbs are achieved through both its antigen binding fragment (Fab and crystallizable fragment (Fc. Fab can specifically recognize tumor associated antigen (TAA and thus modulate TAA-linked downstream signaling pathways that may lead to inhibition of tumor growth, induction of tumor apoptosis and differentiation. The Fc region can further improve mAbs’ efficacy by mediating effector functions such as antibody-dependent cellular cytotoxicity (ADCC, complement-dependent cytotoxicity (CDC and antibody dependent cell-mediated phagocytosis (ADCP. Moreover, Fc is the region interacting with the neonatal Fc receptor (FcRn in a pH-dependent manner that can slow down IgG’s degradation and extend its serum half-life. Loss of the antibody Fc region dramatically shortens its serum half-life and weakens its anti-cancer effects. Given the essential roles that the Fc region plays in the modulation of the efficacy of mAb in cancer treatment, Fc engineering has been extensively studied in the past years. This review focuses on the recent advances in therapeutic Fc engineering that modulates its related effector functions and serum half-life. We also discuss the progress made in aglycosylated mAb development that may substantially reduce cost of manufacture but maintain similar efficacies as conventional glycosylated mAb. Finally, we highlight several Fc engineering based mAbs under clinical trials.

  8. High-precision measurement of the 19Ne half-life and implications for right-handed weak currents.

    Science.gov (United States)

    Triambak, S; Finlay, P; Sumithrarachchi, C S; Hackman, G; Ball, G C; Garrett, P E; Svensson, C E; Cross, D S; Garnsworthy, A B; Kshetri, R; Orce, J N; Pearson, M R; Tardiff, E R; Al-Falou, H; Austin, R A E; Churchman, R; Djongolov, M K; D'Entremont, R; Kierans, C; Milovanovic, L; O'Hagan, S; Reeve, S; Sjue, S K L; Williams, S J

    2012-07-27

    We report a precise determination of the (19)Ne half-life to be T(1/2)=17.262±0.007 s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

  9. Vitamin E plasma kinetics in swine show low bioavailability and short half-life of -α-tocopheryl acetate.

    Science.gov (United States)

    van Kempen, T A T G; Reijersen, M H; de Bruijn, C; De Smet, S; Michiels, J; Traber, M G; Lauridsen, C

    2016-10-01

    Vitamin E is important for animal production because of its effects on health and product quality, but the amount and form required remains controversial. Our objective was to quantify the absolute bioavailability of oral -α-tocopheryl acetate (α-TAc) in swine (22 ± 1 kg and 8 wk old, fitted with jugular catheters) adapted to a diet supplemented with 75 mg/kg -α-TAc; 75 mg/kg was chosen because this level represents the nonweighted average inclusion level in piglet diets across Western key swine-producing countries. For this, a 350-g test meal (6% fat) was supplied at time 0 containing 75 mg deuterated (D9) -α-TAc to 9 animals, and 8 animals received an intravenous () dose containing deuterated (D6) RRR-α-tocopherol (α-T) at one-eighth the oral dose and a test meal without supplemental vitamin E. Plasma samples (12 to 13 per animal) were obtained at incremental intervals over 75 h for analysis of deuterated α-T using liquid chromatography-tandem mass spectrometry. Surprisingly, the i.v. dose rapidly disappeared from plasma and then reappeared. The half-life for this first peak was only 1.7 ± 0.3 min. The second peak had an appearance rate (Ka) of 0.10 ± 0.06 d and a half-life of 5.9 ± 1.2 h. Oral dosing resulted, after a lag of 56 min, in a Ka of 0.91 ± 0.21 d and a half-life of 2.6 ± 0.8 h. The bioavailability for oral α-TAc was 12.5%, whereas the area under the curve was only 5.4%. This low bioavailability, small area under the curve, and short half-life are likely because of various factors, that is, the use of only 6% fat in the diet, the use of the acetate ester and , and the high dose relative to requirements. In conclusion, i.v. dosed vitamin E shows both a rapid and a very slow pool, whereas orally dosed vitamin E shows a single slow pool. The oral material has a very short half-live (44% of i.v. or 2.6 h), low bioavailability (12.5%), and a very small area under the curve (5.4%), bringing into question the efficacy of typical doses of vitamin

  10. A Half-Life Measurement of the 343.4 keV Level in {sup 175}Lu

    Energy Technology Data Exchange (ETDEWEB)

    Hoejeberg, M; Malmskog, S G

    1969-05-15

    Great theoretical interest has recently been shown in the asymptotically forbidden 5/2 5/2+ [402] - 7/2 7/2+ [404] M1-transitions in {sup 181}Ta and {sup 175}Lu . Half-lives of the 5/2 5/2+ [402] level in {sup 175}Lu have been reported which differ by more than a factor of 10. Using an electron-electron coincidence spectrometer the half-life of this level has been re-measured and a value of (0.26 {+-} 0.02) nsec has been established.

  11. Biological half-life and distribution of radiocesium in a contaminated population of green treefrogs Hyla cinerea

    International Nuclear Information System (INIS)

    Dapson, R.W.; Kaplan, L.

    1975-01-01

    Radiocesium content of adult male green treefrogs Hyla cinerea from a contaminated habitat is adequately described by a log normal distribution with mean 2.277 log 10 pCi g -1 dry wt (189.2 pCi g -1 ) and variance of 0.031. There was significant negative correlation of body burden with body length and weight (p 2 = 0.10). Biological half-life of radiocesium in unfed, captive frogs held at 20 deg - 30 deg C averaged 30.1 d. (author)

  12. High-Precision Measurement of the Ne19 Half-Life and Implications for Right-Handed Weak Currents

    Science.gov (United States)

    Triambak, S.; Finlay, P.; Sumithrarachchi, C. S.; Hackman, G.; Ball, G. C.; Garrett, P. E.; Svensson, C. E.; Cross, D. S.; Garnsworthy, A. B.; Kshetri, R.; Orce, J. N.; Pearson, M. R.; Tardiff, E. R.; Al-Falou, H.; Austin, R. A. E.; Churchman, R.; Djongolov, M. K.; D'Entremont, R.; Kierans, C.; Milovanovic, L.; O'Hagan, S.; Reeve, S.; Sjue, S. K. L.; Williams, S. J.

    2012-07-01

    We report a precise determination of the Ne19 half-life to be T1/2=17.262±0.007s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current standard model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.

  13. The effective and environmental half-life of 137Cs at Coral Islands at the former US nuclear test site

    International Nuclear Information System (INIS)

    Robison, William L.; Conrado, Cynthia L.; Bogen, Kenneth T.; Stoker, A. Carol

    2003-01-01

    The United States (US) conducted nuclear weapons testing from 1946 to 1958 at Bikini and Enewetak Atolls in the northern Marshall Islands. Based on previous detailed dose assessments for Bikini, Enewetak, Rongelap, and Utirik Atolls over a period of 28 years, cesium-137 ( 137 Cs) at Bikini Atoll contributes about 85-89% of the total estimated dose through the terrestrial food chain as a result of uptake of 137 Cs by food crops. The estimated integral 30, 50, and 70-year doses were based on the radiological decay of 137 Cs (30-year half-life) and other radionuclides. However, there is a continuing inventory of 137 Cs and 90 Sr in the fresh water portion of the groundwater at all contaminated atolls even though the turnover rate of the fresh groundwater is about 5 years. This is evidence that a portion of the soluble fraction of 137 Cs and 90 Sr inventory in the soil is lost by transport to groundwater when rainfall is heavy enough to cause recharge of the lens, resulting in loss of 137 Cs from the soil column and root zone of the plants. This loss is in addition to that caused by radioactive decay. The effective rate of loss was determined by two methods: (1) indirectly, from time-dependent studies of the 137 Cs concentration in leaves of Pisonia grandis, Guettarda specosia, Tournefortia argentea (also called Messerschmidia), Scaevola taccada, and fruit from Pandanus and coconut trees (Cocos nucifera L.), and (2) more directly, by evaluating the 137 Cs/ 90 Sr ratios at Bikini Atoll. The mean (and its lower and upper 95% confidence limits) for effective half-life and for environmental-loss half-life (ELH) based on all the trees studied on Rongelap, Bikini, and Enewetak Atolls are 8.5 years (8.0 years, 9.8 years), and 12 years (11 years, 15 years), respectively. The ELH based on the 137 Cs/ 90 Sr ratios in soil in 1987 relative to the 137 Cs/ 90 Sr ratios at the time of deposition in 1954 is less than 17 years. The magnitude of the decrease below 17 years depends on

  14. The effective and environmental half-life of 137Cs at Coral Islands at the former US nuclear test site.

    Science.gov (United States)

    Robison, William L; Conrado, Cynthia L; Bogen, Kenneth T; Stoker, A Carol

    2003-01-01

    The United States (US) conducted nuclear weapons testing from 1946 to 1958 at Bikini and Enewetak Atolls in the northern Marshall Islands. Based on previous detailed dose assessments for Bikini, Enewetak, Rongelap, and Utirik Atolls over a period of 28 years, cesium-137 (137Cs) at Bikini Atoll contributes about 85-89% of the total estimated dose through the terrestrial food chain as a result of uptake of 137Cs by food crops. The estimated integral 30, 50, and 70-year doses were based on the radiological decay of 137Cs (30-year half-life) and other radionuclides. However, there is a continuing inventory of 137Cs and 90Sr in the fresh water portion of the groundwater at all contaminated atolls even though the turnover rate of the fresh groundwater is about 5 years. This is evidence that a portion of the soluble fraction of 137Cs and 90Sr inventory in the soil is lost by transport to groundwater when rainfall is heavy enough to cause recharge of the lens, resulting in loss of 137Cs from the soil column and root zone of the plants. This loss is in addition to that caused by radioactive decay. The effective rate of loss was determined by two methods: (1) indirectly, from time-dependent studies of the 137Cs concentration in leaves of Pisonia grandis, Guettarda specosia, Tournefortia argentea (also called Messerschmidia), Scaevola taccada, and fruit from Pandanus and coconut trees (Cocos nucifera L.), and (2) more directly, by evaluating the 137Cs/90Sr ratios at Bikini Atoll. The mean (and its lower and upper 95% confidence limits) for effective half-life and for environmental-loss half-life (ELH) based on all the trees studied on Rongelap, Bikini, and Enewetak Atolls are 8.5 years (8.0 years, 9.8 years), and 12 years (11 years, 15 years), respectively. The ELH based on the 137Cs/90Sr ratios in soil in 1987 relative to the 137Cs/90Sr ratios at the time of deposition in 1954 is less than 17 years. The magnitude of the decrease below 17 years depends on the ELH for 90Sr

  15. The Half-Life of the HSV-1 1.5 kb LAT Intron is similar to the half-Life of the 2.0 kb LAT Intron

    Science.gov (United States)

    Brinkman, Kerry K.; Mishra, Prakhar; Fraser, Nigel W.

    2013-01-01

    Herpes Simplex Virus type 1 (HSV-1) establishes a latent infection in the sensory neurons of the peripheral nervous system of humans. Although about 80 genes are expressed during the lytic cycle of the virus infection, essentially only one gene is expressed during the latent cycle. This gene is known as the latency associated transcript (LAT) and it appears to play a role in the latency cycle through an anti-apoptotic function in the 5’ end of the gene and miRNA encoded along the length of the transcript which down regulate some of the viral immediate early (IE) gene products. The LAT gene is about 8.3 kb long and consists of two exons separated by an unusual intron. The intron between the exons consists of two nested introns. This arrangement of introns has been called a twintron. Furthermore, the larger (2 kb) intron has been shown to be very stable. In this study we measure the stability of the shorter 1.5 kb nested intron and find its half-life is similar to the longer intron. This was achieved by deleting the 0.5 kb overlapping intron from a plasmid construct designed to express the LAT transcript from a tet-inducible promoter, and measuring the half-life of the 1.5 kb intron in tissue culture cells. This finding supports the hypothesis that it is the common branch-point region of these nested introns that is responsible for their stability. PMID:23335177

  16. Dual Constant Domain-Fab: A novel strategy to improve half-life and potency of a Met therapeutic antibody.

    Science.gov (United States)

    Cignetto, Simona; Modica, Chiara; Chiriaco, Cristina; Fontani, Lara; Milla, Paola; Michieli, Paolo; Comoglio, Paolo M; Vigna, Elisa

    2016-06-01

    The kinase receptor encoded by the Met oncogene is a sensible target for cancer therapy. The chimeric monovalent Fab fragment of the DN30 monoclonal antibody (MvDN30) has an odd mechanism of action, based on cell surface removal of Met via activation of specific plasma membrane proteases. However, the short half-life of the Fab, due to its low molecular weight, is a severe limitation for the deployment in therapy. This issue was addressed by increasing the Fab molecular weight above the glomerular filtration threshold through the duplication of the constant domains, in tandem (DCD-1) or reciprocally swapped (DCD-2). The two newly engineered molecules showed biochemical properties comparable to the original MvDN30 in vitro, acting as full Met antagonists, impairing Met phosphorylation and activation of downstream signaling pathways. As a consequence, Met-mediated biological responses were inhibited, including anchorage-dependent and -independent cell growth. In vivo DCD-1 and DCD-2 showed a pharmacokinetic profile significantly improved over the original MvDN30, doubling the circulating half-life and reducing the clearance. In pre-clinical models of cancer, generated by injection of tumor cells or implant of patient-derived samples, systemic administration of the engineered molecules inhibited the growth of Met-addicted tumors. Copyright © 2016 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  17. Fab-dsFv: A bispecific antibody format with extended serum half-life through albumin binding.

    Science.gov (United States)

    Davé, Emma; Adams, Ralph; Zaccheo, Oliver; Carrington, Bruce; Compson, Joanne E; Dugdale, Sarah; Airey, Michael; Malcolm, Sarah; Hailu, Hanna; Wild, Gavin; Turner, Alison; Heads, James; Sarkar, Kaushik; Ventom, Andrew; Marshall, Diane; Jairaj, Mark; Kopotsha, Tim; Christodoulou, Louis; Zamacona, Miren; Lawson, Alastair D; Heywood, Sam; Humphreys, David P

    2016-10-01

    An antibody format, termed Fab-dsFv, has been designed for clinical indications that require monovalent target binding in the absence of direct Fc receptor (FcR) binding while retaining substantial serum presence. The variable fragment (Fv) domain of a humanized albumin-binding antibody was fused to the C-termini of Fab constant domains, such that the VL and VH domains were individually connected to the Cκ and CH1 domains by peptide linkers, respectively. The anti-albumin Fv was selected for properties thought to be desirable to ensure a durable serum half-life mediated via FcRn. The Fv domain was further stabilized by an inter-domain disulfide bond. The bispecific format was shown to be thermodynamically and biophysically stable, and retained good affinity and efficacy to both antigens simultaneously. In in vivo studies, the serum half-life of Fab-dsFv, 2.6 d in mice and 7.9 d in cynomolgus monkeys, was equivalent to Fab'-PEG.

  18. Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m

    Science.gov (United States)

    Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Grinyer, G. F.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.

    2009-10-01

    The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada. A beam of ˜10^5 ^26Al^m/s was delivered in October 2007 and its decay was observed using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [4pt] [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 79, 055502 (2009).

  19. High-Precision Half-Life and Branching Ratio Measurements for the Superallowed β+ Emitter 26Alm

    Science.gov (United States)

    Finlay, P.; Svensson, C. E.; Demand, G. A.; Garrett, P. E.; Green, K. L.; Leach, K. G.; Phillips, A. A.; Rand, E. T.; Ball, G.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Grinyer, G. F.; Sumithrarachchi, C. S.; Williams, S. J.; Triambak, S.

    2013-03-01

    High-precision half-life and branching-ratio measurements for the superallowed β+ emitter 26Alm were performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ≤ 15 ppm at 90% C.L. was determined for the sum of all possible non-analogue β+/EC decay branches of 26Alm, yielding a superallowed branching ratio of 100.0000+0-0.0015%. A value of T1/2 = 6:34654(76) s was determined for the 26Alm half-life which is consistent with, but 2.5 times more precise than, the previous world average. Combining these results with world-average measurements yields an ft value of 3037.58(60) s, the most precisely determined for any superallowed emitting nucleus to date. This high-precision ft value for 26Alm provides a new benchmark to refine theoretical models of isospin-symmetry-breaking effects in superallowed β decays.

  20. RBC-/Cr-51/ half-life and albumin turnover in growing Beagle dogs during chronic radial acceleration

    Science.gov (United States)

    Beckman, D. A.; Evans, J. W.; Oyama, J.

    1979-01-01

    The effects of chronic centrifugation on growing Beagle dogs exposed to -2 or -2.6 Gx on albumin and RBC turnover rates, albumin concentration and space, and total blood volume were determined and compared with caged and run control of animals. Albumin-(I-125) and autologous RBC-(Cr-51) preparations were injected into all dogs at day 82 of the centrifugation periods, and the disappearance curves were determined by successive bleedings of the animals over the next 35 d, during which the centrifugation was continued. There were no differences in albumin turnover rates or space. Two populations of RBCs were found in both centrifugated groups, one with a normal half-life of 27 + or - 1 S.E.M. d, and one with a significantly (p less than 0.01) shorter half-life of 15 + or - 2 S.E.M. d. An absolute polycythemia was also observed in both centrifuged groups. The results suggest that chronic centrifugation acts through some as-yet unknown mechanism to affect RBC population kinetics.

  1. An improved method for determination of technetium-99m half-life for the quality assurance procedures of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Abd Jalil Abd Hamid; Juhari Mohd Yusof; Zakaria Ibrahim; Wan Mohd Ferdaus Wan Ishak; Mohamad Hafiz Ahmad

    2009-01-01

    An improve method for identity tests of technetium-99m for the quality assurance procedures are presented. Computerized methods based on the least-squares of decay curve fitting for half-life estimation of technetium-99m was tested. Thus, least-squares method was employ as a decay curve fitting procedures in our software. Theoretical calculated half-life of technetium-99m for evaluation was performed for comparison. In Fig. 3 is shown, the decay curve fitting of a sample over one second counting time interval. The R2 value of the curve suggests that the time of the study was too short to obtain acceptable value. A similar measurement for another data set was done for a longer period of time and in Table 1 is shown a representative decay curve fitting. The value was found to be 6.006 hours with a discrepancy of -0.28% from the value taken from the literature. The value is in agreement with the literature for time interval greater than 2 seconds. The results obtained by this method show that the used of least-squares method for decay curve fitting are appropriate for routine identity tests. This confirmed that the least-squares method applied in our decay curve fitting software are remarkably improved and convenient for routine identity tests purposes. (Author)

  2. Determination of short half-life elements in biological, foodstuff, and environmental samples qualitatively by neutron activation analysis

    International Nuclear Information System (INIS)

    Syukria Kurniawati; Muhayatun Santoso; Diah Dwiana Lestiani

    2010-01-01

    NAA applications at routine operation power of 15 MW at Multipurpose Reactor GA Siwabessy (MPR-GAS) for sample matrices analysis have been widely applied. However, the results are not optimum for some matrices especially for short half-live elements. Preliminary study of short half-life elements determination in biological, foodstuff, and environmental samples using 1 MW power have been conducted to solve this problem. The samples were irradiated in rabbit system of MPR-GAS for 5 minutes, counted for 200 seconds by HPGe detector, and the spectrum were analyzed further using software Genie 2000 and Bandung NAA Utility. Analysis under 1 MW power on biological and foodstuff samples were capable to detect eight elements: Al, Br, CI, Ca, I, K, Mg, Ti, and Na for biological samples; Al, Br, CI, Ca, I, K, Mg, Mn, and Na for foodstuff samples, while at 15 MW power only three elements (CI, K, Na) were detected. At 1 MW power the counting process is more optimum due to smaller radiation exposure and dead time. For the environmental samples, the number of elements detected by 1 MW and 15 MW powers did not differ significantly. Generally, the results on the three types of samples showed that the elements of short half-life are better detected at 1 MW than that of 15 MW power. Further research needs to be done to obtain the optimum analytical conditions for irradiation and counting time determination. (author)

  3. Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

    International Nuclear Information System (INIS)

    Villeneuve, Maxime; Leclerc, Ghyslain; Lessard, Etienne; Pouliot, Jean; Beaulieu, Luc

    2008-01-01

    The robustness of treatment planning to prostatic edema for three different isotopes ( 125 I, 103 Pd, and 131 Cs) is explored using dynamical dose calculations on 25 different clinical prostate cases. The treatment plans were made using the inverse planning by simulated annealing (IPSA) algorithm. The prescription was 144, 127, and 125 Gy for 125 I, 131 Cs, and 103 Pd, respectively. For each isotope, three dose distribution schemes were used to impose different protection levels to the urethra: V 120 =0%, V 150 =0%, and V 150 =30%. Eleven initial edema values were considered ranging from 1.0 (no edema) to 2.0 (100%). The edema was assumed to resolve exponentially with time. The prostate volume, seed positions, and seed activity were dynamically tracked to produce the final dose distribution. Edema decay half-lives of 10, 30, and 50 days were used. A total of 675 dynamical calculations were performed for each initial edema value. For the 125 I isotope, limiting the urethra V 120 to 0% leads to a prostate D 90 under 140 Gy for initial edema values above 1.5. Planning with urethra V 150 at 0% provides a good response to the edema; the prostate D 90 remains higher than 140 Gy for edema values up to 1.8 and a half-life of 30 days or less. For 103 Pd, the prostate D 90 is under 97% of the prescription dose for approximately 66%, 40%, and 30% of edema values for urethra V 120 =0%, V 150 =0%, and V 150 =30%, respectively. Similar behavior is seen for 131 Cs and the center of the prostate becomes 'cold' for almost all edema scenarios. The magnitude of the edema following prostate brachytherapy, as well as the half-life of the isotope used and that of the edema resorption, all have important impacts on the dose distribution. The 125 I isotope with its longer half-life is more robust to prostatic edema. Setting up good planning objectives can provide an adequate compromise between organ doses and robustness. This is even more important since seed misplacements will contribute

  4. Direct Deposition Effect on the Distribution of Radiocesium in Persimmon Trees and the Effective Half-life

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, Keiko; Uchida, Shigeo [National Institute of Radiological Sciences, Anagawa 4-9-1, Inage-ku, Chiba 263-7444 (Japan)

    2014-07-01

    Radiocesium ({sup 137}Cs) concentrations in persimmon tree tissues collected at Chiba, about 220 km south from Fukushima Daiichi nuclear power plant (FDNPP), were measured to obtain half-life of radiocesium in the trees. Persimmon (Diospyros kaki) is a deciduous tree and bears edible fruits in autumn. There were no leaves when the sampling area was received the radioactive fallout in March 2011 due to the FDNPP accident; the amount of {sup 137}Cs radioactivity in this area was ca. 13 kBq/m{sup 3} Both {sup 137}Cs and {sup 134}Cs were found in the newly emerged shoots of the persimmon trees collected at 26 April 2011 mainly due to foliar uptake. The concentrations were 1.1 kBq/kg-dry for {sup 137}Cs and 1.3 kBq/kg-dry for {sup 134}Cs. After that, continuous sampling of leaves, branches and fruits of the persimmon trees had been carried out for two years. Immediately after the collection, samples were transferred to our laboratory and weighed to obtain fresh weight. Leaf samples were usually separated into two portions; one portion was washed with tap water to remove dust from the surface and the other portion was not treated. For fruit samples, if it is possible, fruit flesh, peal and non-edible part were separated. All the samples were oven-dried at 80 deg. C for three days at least. Each dried sample was chopped into fine pieces, mixed well, and then transferred into plastic vessels separately. Radioactivity concentration was measured by a Ge-detecting system (Seiko EG and G Ortec) using 3000-40000 s counting intervals. By August 14, 2013, about 140 samples were collected from the trees; about 60 samples were leaves (both washed and untreated). Radiocesium concentrations in tree leaves decreased with time, and the effective half-life was about 190 d; the value was similar to those in branches (160 d for new branches, and 250 d for 1-2 y.o. branches) and fruits (250 d for fruit flesh and 230 d for peals). Thus we concluded that the half-life of radiocesium in

  5. Energy dependence of average half-life of delayed neutron precursors in fast neutron induced fission of 235U and 236U

    International Nuclear Information System (INIS)

    Isaev, S.G.; Piksaikin, L.E.; Kazakov, L.E.; Tarasko, M.Z.

    2000-01-01

    The measurements of relative abundances and periods of delayed neutrons from fast neutron induced fission of 235 U and 236 U have been made at the electrostatic accelerator CG-2.5 at IPPE. The preliminary results were obtained and discussed in the frame of the systematics of the average half-life of delayed neutron precursors. It was shown that the average half-life value in both reactions depends on the energy of primary neutrons [ru

  6. Tests of the methods of analysis of picosecond lifetimes and measurement of the half-life of the 569.6 keV level in 207Pb

    International Nuclear Information System (INIS)

    Lima, E. de; Kawakami, H.; Lima, A. de; Hichwa, R.; Ramayya, A.V.; Hamilton, J.H.; Dunn, W.; Kim, H.J.

    1978-01-01

    Customarily one extracts the half-life of the nuclear state from a delayed time spectrum by an analysis of the centroid shift, the slope and lately by the convolution method. Recently there have been two formulas relating the centroid shift to the half-life of the nuclear state. These two procedures can give different results for the half-life when Tsub(1/2) the same order or less than the time width of one channel. An extensive investigation of these two formulas and precedures has been made by measuring the half-life of the first excited state in 207 Pb at 569.6 keV. This analysis confirms Bay's formula relating the centroid shift to the half-life of the state. The half-life of the 569.6 keV level in 207 Pb is measured to be (129+-3) ps in excellent agreement with Weisskopf's single particle estimate of 128 ps for an E2 transition. (Auth.)

  7. Phenytoin shortens the half-life of the hypoxic cell radiosensitizer misonidazole in man: implications for possible reduced toxicity

    International Nuclear Information System (INIS)

    Workman, P.; Bleehen, N.M.; Wiltshire, C.R.; Cambridge Univ.

    1980-01-01

    Results are described of a preliminary study of the effects of phenytoin, (commonly used as an anticonvulsant in the treatment of patients with brain tumours), on the plasma pharmacokinetics of misonidazole (MISO) in man. Previous studies have shown that pretreatment with phenytoin shortens the half-life of MISO in dogs and mice by induction of drug metabolizing enzymes, and also reduces the acute lethal effects of MISO in mice. In this study patients with various types of malignancy and with cerebral metastases were given MISO before and after a course of phenytoin. Others were assessed as controls without phenytoin administration. Plasma concentrations of MISO were determined in blood samples taken before and at various times after administration. A summary of the pharmacokinetic data obtained is given. (author)

  8. KINETIC MODELLING AND HALF LIFE STUDY OF ADSORPTIVE BIOREMEDIATION OF SOIL ARTIFICIALLY CONTAMINATED WITH BONNY LIGHT CRUDE OIL

    Directory of Open Access Journals (Sweden)

    Samuel Enahoro Agarry

    2015-06-01

    Full Text Available In this study, comparative potential effects of commercial activated carbon (CAC and plantain peel-derived biochar (PPBC of different particle sizes and dosage to stimulate petroleum hydrocarbon biodegradation in soil were investigated. Microcosms containing soil were spiked with weathered Bonny light crude oil (WBLCO (10% w/w and amended with different particle sizes (0.02, 0.07 and 0.48 mm and dosage (20, 30 and 40 g of CAC and PPBC, respectively. The bioremediation experiments were carried out for a period of 28 days under laboratory conditions. The results showed that there was a positive relationship between the rate of petroleum hydrocarbons reduction and presence of the CAC and PPBC in crude oil contaminated soil microcosms. The WBLCO biodegradation data fitted well to the first-order kinetic model. The model revealed that WBLCO contaminated-soil microcosms amended with CAC and PPBC had higher biodegradation rate constants (k as well as lower half-life times (t1/2 than unamended soil (natural attenuation remediation system. The rate constants increased while half-life times decreased with decreased particle size and increased dosage of amendment agents. ANOVA statistical analysis revealed that WBLCO biodegradation in soil was significantly (p = 0.05 influenced by the addition of CAC and biochar amendment agents, respectively. However, Tukey’s post hoc test (at p = 0.05 showed that there was no significant difference in the bioremediation efficiency of CAC and PPBC. Thus, amendment of soils with biochar has the potential to be an inexpensive, efficient, environmentally friendly and relatively novel strategy to mitigate organic compound-contaminated soil.

  9. Elimination of americium-241 after a case of accidental inhalation

    International Nuclear Information System (INIS)

    Edvardsson, K.A.; Lindgren, L.

    1976-01-01

    In handling a 241 Am source one person received an internal contamination of about 140 nCi of americium oxide, which was deposited in the lung region. Elimination of the activity was followed for more than 3 months by external gamma counting and excreta analyses. During the first week after the inhalation about 80% of the total intake was eliminated with an effective half-life of less than 2 days. The remaining activity, deposited in the lung region, was eliminated with an effective half-life of about 17 days. About 15% of the activity eliminated from the lung region from the 10th to the 50th day was eliminated in the faeces. (author)

  10. Prediction of clearance, volume of distribution and half-life by allometric scaling and by use of plasma concentrations predicted from pharmacokinetic constants: a comparative study.

    Science.gov (United States)

    Mahmood, I

    1999-08-01

    Pharmacokinetic parameters (clearance, CL, volume of distribution in the central compartment, VdC, and elimination half-life, t1/2beta) predicted by an empirical allometric approach have been compared with parameters predicted from plasma concentrations calculated by use of the pharmacokinetic constants A, B, alpha and beta, where A and B are the intercepts on the Y axis of the plot of plasma concentration against time and alpha and beta are the rate constants, both pairs of constants being for the distribution and elimination phases, respectively. The pharmacokinetic parameters of cefpiramide, actisomide, troglitazone, procaterol, moxalactam and ciprofloxacin were scaled from animal data obtained from the literature. Three methods were used to generate plots for the prediction of clearance in man: dependence of clearance on body weight (simple allometric equation); dependence of the product of clearance and maximum life-span potential (MLP) on body weight; and dependence of the product of clearance and brain weight on body weight. Plasma concentrations of the drugs were predicted in man by use of A, B, alpha and beta obtained from animal data. The predicted plasma concentrations were then used to calculate CL, VdC and t1/2beta. The pharmacokinetic parameters predicted by use of both approaches were compared with measured values. The results indicate that simple allometry did not predict clearance satisfactorily for actisomide, troglitazone, procaterol and ciprofloxacin. Use of MLP or the product of clearance and brain weight improved the prediction of clearance for these four drugs. Except for troglitazone, VdC and t1/2beta predicted for man by use of the allometric approach were comparable with measured values for the drugs studied. CL, VdC and t1/2beta predicted by use of pharmacokinetic constants were comparable with values predicted by simple allometry. Thus, if simple allometry failed to predict clearance of a drug, so did the pharmacokinetic constant

  11. Label-free Fab and Fc affinity/avidity profiling of the antibody complex half-life for polyclonal and monoclonal efficacy screening.

    Science.gov (United States)

    Read, Thomas; Olkhov, Rouslan V; Williamson, E Diane; Shaw, Andrew M

    2015-09-01

    A unified approach to affinity screening for Fab and Fc interactions of an antibody for its antigen and FcγR receptor has been developed. An antigen array is used for the Fab affinity and cross-reactivity screening and protein A/G proxy is the FcγR receptor. The affinities are derived using a simple 1:1 binding model with a consistent error analysis. The association and dissociation kinetics are measured over optimised times for accurate determination. The Fab/Fc affinities are derived for ten antibodies: mAb-actin (mouse), pAb-BSA (sheep), pAb-collagen V (rabbit), pAb-CRP (goat), mAb-F1 (mouse), mAbs (mouse) 7.3, 12.3, 29.3, 36.3 and 46.3 raised against LcrV in Yersinia pestis. The rate of the dissociation of antigen-antibody complexes relates directly to their immunological function as does the Fc-FcγR complex and a new half-life plot has been defined with a Fab/Fc half-life range of 17-470 min. The upper half-life value points to surface avidity. Two antibodies that are protective as an immunotherapy define a Fab half-life >250 min and an Fc half-life >50 min as characteristics of ideal interactions which can form the basis of an antibody screen for immunotherapy.

  12. HPLC Analysis to Determine the Half-life and Bioavailability of the Termiticides Bifenthrin and Fipronil in Soil.

    Science.gov (United States)

    Manzoor, F; Pervez, M

    2017-12-05

    The aim of this study was to test the bioavailability and degradation in soil of the termiticides bifenthrin and fipronil, which are used to treat subterranean termites (Heterotermes indicola, Wasmann). Soil collected from different areas of Lahore was categorized as sandy clay loam (SCL) or sandy loam (SL). Laboratory bioassays were conducted to determine the bioavailability ratio of bifenthrin and fipronil in each type of soil after different periods of time. LT50 values were determined posttreatment at different time intervals. Regarding soil type, both termiticides were more effective in SL soil, compared with SCL soil posttreatment. There were significant differences in termite mortality in treated compared with untreated control samples (P bifenthrin (maximum, 1,002 and 1,262 d in SCL soil and SL soil, respectively) indicated that it persisted in both soil types at all concentrations. The maximum calculated half-life values of fipronil were 270 and 555 d in SCL and SL soil, respectively. At lower concentrations and over longer periods of time, fipronil completely degraded in SL soil, while a negligible amount was detected in SCL soil. Termiticide concentration decreased over time, as did the termiticide recovery rate. Overall, bifenthrin was more persistent than fipronil under all treatment conditions tested. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. Dependence of Rn adsorption rate and effective half-life time on diffusion barrier type and moving air environment

    International Nuclear Information System (INIS)

    Arafa, Wafaa; Badran, Heba

    2005-01-01

    The variation of the adsorbed radon rate during the exposure time using charcoal canister was studied applying moving air environment inside the radon chamber and compared to the static air measurements. The air movement increases the accumulation time leading to more accurate results. Different types of membrane have been tested as diffusion barrier for activated charcoal canisters. The Makrofol and aluminized polycarbonate improve the adsorption/desorption rate more than the polyehylene membrane. The measured effective half-life time showed a remarkable correlation with the previously measured permeability constant for corresponding membranes. Different types of commercially available charcoal were investigated to develop a local version of charcoal canister for radon measurements. Applying static and moving air environments, the break point and radon collection efficiency were determined at different temperatures. Both of the temperature and air movement accelerate the appearance of the break point. Th efficiency of the locally developed charcoal is 87% and 84.5% of that Calgon PCB charcoal used by EPA. (author)

  14. Development of controller of acquisition and sample positioner for activation for use in measurements of short half-life radioisotopes

    International Nuclear Information System (INIS)

    Secco, Marcello

    2016-01-01

    High resolution gamma spectroscopy measurements have several applications. Those involving short half-life radioisotope measurements may present low precision problems when the radioactive source is far from detector end cup and in the very high activity situations also can present accuracy loss due to dead time and pile-up effects. A way to overcome these problems is changing the source detector distance as the activity is decreasing, and thereby maximizing the statistical counting. In the present study, the Controller of Acquisition and Sample Positioner for Activation (CASPA) was developed. It is a low cost and weight device, made with low atomic number materials designed to assist gamma spectroscopy measurements, which is able to control the distance between the source and the detector, even allowing that there is a change of this distance during the measurement process. Because it is automated it optimizes the time of the operator, who has complete freedom to program their routine measurements in the device besides minimizing the radiation dose in the operator. An interface that allow the user control the CASPA system and to program the acquisition system was created. Tests aiming to optimize the operation of CASPA system were carried out and the safety of the CASPA operation was verified, it was not presented any failure during their tests. It was applied the repeatability tests by the acquisition 60 Co standard source and was found that the positioning of automated system has reproduced the results of static system with a 95% of confidence level. (author)

  15. Increased half-life and enhanced potency of Fc-modified human PCSK9 monoclonal antibodies in primates.

    Directory of Open Access Journals (Sweden)

    Yijun Shen

    Full Text Available Blocking proprotein convertase subtilisin kexin type 9 (PCSK9 binding to low-density lipoprotein receptor (LDLR can profoundly lower plasma LDL levels. Two anti-PCKS9 monoclonal antibodies (mAbs, alirocumab and evolocumab, were approved by the FDA in 2015. The recommended dose is 75 mg to 150 mg every two weeks for alirocumab and 140mg every two weeks or 420 mg once a month for evolocumab. This study attempted to improve the pharmacokinetic properties of F0016A, an IgG1 anti-PCKS9 mAb, to generate biologically superior molecules. We engineered several variants with two or three amino acid substitutions in the Fc fragment based on prior knowledge. The Fc-modified mAbs exhibited increased binding to FcRn, resulting in prolonged serum half-life and enhanced efficacy in vivo. These results demonstrate that Fc-modified anti-PCKS9 antibodies may enable less frequent or lower dosing of antibodies by improved recycling into the blood.

  16. Diffusion and release of noble gas and halogen fission products with several days half-life in UO2 particle

    International Nuclear Information System (INIS)

    Fang Chao

    2013-01-01

    The exact solutions of diffusion and release model of noble gas and halogen fission products in UO 2 particle of HTGR were built under the conditions of adsorption effect and other physical processes. The corresponding release fractions (F(t)) and the ratio of release and productive amounts (R(t)/B (t)) of fission products were also derived. Furthermore, the F(t) and R(t)/B(t) of 131 I, 131 IXe m , 133 Xe and 133 Xe m whose half-lifes are several days in UO 2 particle with the exact solutions, approximate solutions and corresponding numerical solutions under different temperature histories of reactor core were investigated. The results show that the F(t) and R(t)/B(t) are different in numerical values unless the time of release is long enough. The properties of conservation of exact solutions are much more reasonable than the ones of approximate solutions. It is also found that the results of exact solutions approach the actual working conditions more than the approximate and numerical solutions. (author)

  17. Developments in human growth hormone preparations: sustained-release, prolonged half-life, novel injection devices, and alternative delivery routes

    Directory of Open Access Journals (Sweden)

    Cai Y

    2014-07-01

    Full Text Available Yunpeng Cai,1,2 Mingxin Xu,2 Minglu Yuan,2 Zhenguo Liu,1 Weien Yuan2 1Department of Neurology, Xinhua Hospital, School of Medicine, 2School of Pharmacy, Shanghai Jiao Tong University, Shanghai, People’s Republic of China Abstract: Since the availability of recombinant human growth hormone (rhGH enabled the application of human growth hormone both in clinical and research use in the 1980s, millions of patients were prescribed a daily injection of rhGH, but noncompliance rates were high. To address the problem of noncompliance, numerous studies have been carried out, involving: sustained-release preparations, prolonged half-life derivatives, new injectors that cause less pain, and other noninvasive delivery methods such as intranasal, pulmonary and transdermal deliveries. Some accomplishments have been made and launched already, such as the Nutropin Depot® microsphere and injectors (Zomajet®, Serojet®, and NordiFlex®. Here, we provide a review of the different technologies and illustrate the key points of these studies to achieve an improved rhGH product. Keywords: intranasal, pulmonary, transdermal, microsphere, microneedle, hydrogel

  18. Half-life, branching-ratio, and Q-value measurement for the superallowed 0+→0+β+ emitter 42Ti

    International Nuclear Information System (INIS)

    Nieto, T. Kurtukian; Souin, J.; Audirac, L.; Blank, B.; Giovinazzo, J.; Eronen, T.; Aeystoe, J.; Elomaa, V.-V.; Hager, U.; Hakala, J.; Jokinen, A.; Kankainen, A.; Karvonen, P.; Kessler, T.; Moore, I. D.; Penttilae, H.; Rahaman, S.; Reponen, M.; Rissanen, J.; Saastamoinen, A.

    2009-01-01

    The half-life, the branching ratio, and the decay Q value of the superallowed β emitter 42 Ti were measured in an experiment performed at the JYFLTRAP facility of the Accelerator Laboratory of the University of Jyvaeskylae. 42 Ti is the heaviest T z =-1 nucleus for which high-precision measurements of these quantities have been tried. The half-life (T 1/2 =208.14±0.45 ms) and the Q value [Q EC =7016.83(25) keV] are close to or reach the required precision of about 0.1%. The branching ratio for the superallowed decay branch [BR=47.7(12)%], a by-product of the half-life measurement, does not reach the necessary precision yet. Nonetheless, these results allow one to determine the experimental ft value and the corrected Ft value to be 3114(79) and 3122(79) s, respectively.

  19. Analysis of existing data and specification of an experiment to determine the 252Cf half-life to the required degree of accuracy

    International Nuclear Information System (INIS)

    Lorenz, A.; Kharitonov, I.A.

    1994-02-01

    The methods used and the results obtained in measurements of the 252 Cf half-life are analyzed. In calculating the weighted mean value, additional error components as well as those given by the authors are taken into account. In order to reduce the error in the weighted mean value to less than 0.1%, the need and the requirements for an exact measurement are specified. A half-life of 2.6473±0.0028 years is recommended. (author). 16 refs, 3 tabs

  20. A Two-pronged Binding Mechanism of IgG to the Neonatal Fc Receptor Controls Complex Stability and IgG Serum Half-life

    DEFF Research Database (Denmark)

    Jensen, Pernille Foged; Schoch, Angela; Larraillet, Vincent

    2017-01-01

    The success of recombinant monoclonal immunoglobulins (IgG) is rooted in their ability to target distinct antigens with high affinity combined with an extraordinarily long serum half-life, typically around 3 weeks. The pharmacokinetics of IgGs is intimately linked to the recycling mechanism...... half-life of ∼8 days. Here we dissect the molecular origins of excessive FcRn binding in therapeutic IgGs using a combination of hydrogen/deuterium exchange mass spectrometry and FcRn affinity chromatography. We provide experimental evidence for a two-pronged IgG-FcRn binding mechanism involving direct...

  1. Ceramide binding to anandamide increases its half-life and potentiates its cytotoxicity in human neuroblastoma cells.

    Science.gov (United States)

    Di Scala, Coralie; Mazzarino, Morgane; Yahi, Nouara; Varini, Karine; Garmy, Nicolas; Fantini, Jacques; Chahinian, Henri

    2017-06-01

    Anandamide (AEA) is a ubiquitous lipid that exerts neurotransmitter functions but also controls important biological functions such as proliferation, survival, or programmed cell death. The latter effects are also regulated by ceramide, a lipid enzymatically generated from sphingomyelin hydrolysis by sphingomyelinase. Ceramide has been shown to increase the cellular toxicity of AEA, but the mechanisms controlling this potentiating effect remained unclear. Here we have used a panel of in silico, physicochemical, biochemical and cellular approaches to study the crosstalk between AEA and ceramide apoptotic pathways. Molecular dynamics simulations indicated that AEA and ceramide could form a stable complex in phosphatidylcholine membranes. Consistent with these data, we showed that AEA can specifically insert into ceramide monolayers whereas it did not penetrate into sphingomyelin membranes. Then we have studied the effects of ceramide on AEA-induced toxicity of human neuroblastoma cells. In these experiments, the cells have been either naturally enriched in ceramide by neutral sphingomyelinase pre-incubation or treated with C2-ceramide, a biologically active ceramide analog. Both treatments significantly increased the cytotoxicity of AEA as assessed by the MTS mitochondrial toxicity assay. This effect was correlated with the concomitant accumulation of natural ceramide (or its synthetic analog) and AEA in the cells. A kinetic study of AEA hydrolysis showed that ceramide inhibited the fatty acid amino hydrolase (FAAH) activity in cell extracts. Taken together, these data suggested that ceramide binds to AEA, increases its half-life and potentiates its cytotoxicity. Overall, these mechanisms account for a functional cross-talk between AEA and ceramide apoptotic pathways. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Eliminating armaments

    International Nuclear Information System (INIS)

    Adams, R.

    1998-01-01

    The end of Cold War induced optimistic projections concerning disarmament, elimination of nuclear weapons, elimination of massive inequities - poverty, hatred, racism. All these goals should be achieved simultaneously, but little has been achieved so far

  3. Measurement of the half-life of 60Fe using the Argonne FN tandem-superconducting Linac system as an accelerator mass spectrometer

    International Nuclear Information System (INIS)

    Kutschera, W.; Billquist, P.J.; Frekers, D.

    1983-01-01

    An experiment to improve the accuracy in the half-life value of 60 Fe by measuring both the amount of 60 Fe nuclei and the decay-rate of a spallation produced sample using the relation dN/dt = -lambda N is briefly discussed

  4. Glucagon-like Peptide 1 Conjugated to Recombinant Human Serum Albumin Variants with Modified Neonatal Fc Receptor Binding Properties. Impact on Molecular Structure and Half-Life

    DEFF Research Database (Denmark)

    Bukrinski, Jens T.; Sønderby, Pernille; Antunes, Filipa

    2017-01-01

    Glucagon-like peptide 1 (GLP-1) is a small incretin hormone stimulated by food intake, resulting in an amplification of the insulin response. Though interesting as a drug candidate for the treatment of type 2 diabetes mellitus, its short plasma half-life of less than 3 minutes limits its clinical...... use. A strategy to extend the half-life of GLP-1 utilizes the long half-life of human serum albumin (HSA) by combining the two via chemical conjugation or genetic fusion. HSA has a plasma half-life of around 21 days owing to its interaction with the neonatal Fc receptor (FcRn) expressed in endothelial...... with the available structural information on the FcRn and GLP-1 receptor (GLP-1R) obtained from X-ray crystallography, we can explain the observed in-vitro and in-vivo behaviour. We conclude that the conjugation of GLP-1 to rHSA does not affect the interaction between rHSA and FcRn, while the observed decrease...

  5. New limit on the half-life of 78Kr with respect to the 2K(2ν)-capture decay mode

    International Nuclear Information System (INIS)

    Gavriljuk, Ju.M.; Kuzminov, V.V.; Osetrova, N.Ya.; Ratkevich, S.S.

    2000-01-01

    The features of data accumulated for 1817 h in an experimental search for the 2K(2ν)-capture mode of 78 Kr decay are discussed. A new limit on the half-life for this decay is found: T 1sol2 ≥ 2.3 x 10 20 yr (at a 90% C.L.)

  6. Platelet half-life in patients with primary hyperlipoproteinemia type IIa, IIb, and IV according to Fredrickson with and without clinical signs of atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, E; Sinzinger, H; Widhalm, K; Kaliman, J; Hoefer, R [Vienna Univ. (Austria). 2. Medizinische Klinik; Ludwig Boltzmann-Institut fuer Nuklearmedizin, Vienna (Austria); Vienna Univ. (Austria). Kinderklinik; Vienna Univ. (Austria). Kardiologische Klinik)

    1982-09-01

    It is generally accepted that platelet half-life is shortened in atherosclerotic vascular diseases. Concerning changes due to hyperlipoproteinemia (HLP), however, there exist only few data. Therefore, we examined the platelet-half life in 60 patients with recently discovered HLP type IIa, IIb and IV according to Fredrickson before treatment in comparison to 60 controls. 33 of the HLP-patients had no clinical symptoms of angiopathy. 27 patients suffered from peripheral vascular disease or from coronary heart disease as verified by angiography. The labelling of autologous platelets was performed with 100..mu..Ci of /sup 111/Indium-oxine-sulfate at 37/sup 0/C for 5 minutes. The mean labelling efficiency was 90%, the recovery after 2 hours about 70%. Serum lipoproteins were estimated by means of ultracentrifugation and polyanionprecipitation according to Lipid Research Clinic Methods. In the patients with HLP platelet half-life was significantly shortened in comparison to the control group (p < 0.01). These changes were most pronounced in patients with HLP-type IIa and with atherosclerotic lesions, respectively. In patients with HLP-type IIa a very close correlation could be demonstrated between platelet half-life and LDL-cholesterol (r = -0.72; p < 0.001) as well as total cholesterol (r = -0.73; p < 0.001). These data prove that in HLP in-vivo platelet function as measured by platelet survival is significantly influenced even before the occurrence of clinically relevant symptoms of atherosclerosis.

  7. A new value for the half-life of {sup 10}Be by Heavy-Ion Elastic Recoil Detection and liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Korschinek, G., E-mail: Gunther.Korschinek@ph.tum.d [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Bergmaier, A. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Faestermann, T. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Gerstmann, U.C. [Helmholtz Zentrum Muenchen, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstaedter Landstr. 1, D-85764 Neuherberg (Germany); Knie, K.; Rugel, G. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Wallner, A. [VERA Laboratory, Faculty of Physics, University of Vienna, Waehringer Strasse 17, A-1090 Wien (Austria); Dillmann, I. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Dollinger, G. [Universitaet der Bundeswehr Muenchen, Fakultaet fuer Luft- und Raumfahrttechnik, Institut fuer Angewandte Physik und Messtechnik LRT2, Werner-Heisenberg-Weg 39, D-85577 Neubiberg (Germany); Lierse von Gostomski, Ch. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany); Kossert, K. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Maiti, M.; Poutivtsev, M. [Physik Department, Technische Universitaet Muenchen, D-85748 Garching (Germany); Remmert, A. [Lehrstuhl fuer Radiochemie, Technische Universitaet Muenchen, D-85748 Garching (Germany)

    2010-01-15

    The importance of {sup 10}Be in different applications of accelerator mass spectrometry (AMS) is well-known. In this context the half-life of {sup 10}Be has a crucial impact, and an accurate and precise determination of the half-life is a prerequisite for many of the applications of {sup 10}Be in cosmic-ray and earth science research. Recently, the value of the {sup 10}Be half-life has been the centre of much debate. In order to overcome uncertainties inherent in previous determinations, we introduced a new method of high accuracy and precision. An aliquot of our highly enriched {sup 10}Be master solution was serially diluted with increasing well-known masses of {sup 9}Be. We then determined the initial {sup 10}Be concentration by least square fit to the series of measurements of the resultant {sup 10}Be/{sup 9}Be ratio. In order to minimize uncertainties because of mass bias which plague other low-energy mass spectrometric methods, we used for the first time Heavy-Ion Elastic Recoil Detection (HI-ERD) for the determination of the {sup 10}Be/{sup 9}Be isotopic ratios, a technique which does not suffer from difficult to control mass fractionation. The specific activity of the master solution was measured by means of accurate liquid scintillation counting (LSC). The resultant combination of the {sup 10}Be concentration and activity yields a {sup 10}Be half-life of T{sub 1/2} = 1.388 +- 0.018 (1 s, 1.30%) Ma. In a parallel but independent study (Chmeleff et al. ), found a value of 1.386 +- 0.016 (1.15%) Ma. Our recommended weighted mean and mean standard error for the new value for {sup 10}Be half-life based on these two independent measurements is 1.387 +- 0.012 (0.87%) Ma.

  8. Analytical studies by activation. Part A and B: Counting of short half-life radio-nuclides. Part C: Analytical programs for decay curves

    International Nuclear Information System (INIS)

    Junod, E.

    1966-03-01

    Part A and B: Since a radio-nuclide of short half-life is characterized essentially by the decrease in its activity even while it is being measured, the report begins by recalling the basic relationships linking the half-life the counting time, the counting rate and the number of particles recorded. The second part is devoted to the problem of corrections for counting losses due to the idle period of multichannel analyzers. Exact correction formulae have been drawn up for the case where the short half-life radionuclide is pure or contains only a long half-life radio-nuclide. By comparison, charts have been drawn up showing the approximations given by the so-called 'active time' counting and by the counting involving the real time associated with a measurement of the overall idle period, this latter method proving to be more valid than the former. A method is given for reducing the case of a complex mixture to that of a two-component mixture. Part C: The problems connected with the qualitative and quantitative analysis of the decay curves of a mixture of radioactive sources of which one at least has a short half-life are presented. A mathematical description is given of six basic processes for which some elements of Fortran programs are proposed. Two supplementary programs are drawn up for giving an overall treatment of problems of dosage in activation analysis: one on the basis of a simultaneous irradiation of the sample and of one or several known samples, the other with separate irradiation of the unknown and known samples, a dosimeter (activation, or external) being used for normalizing the irradiation flux conditions. (author) [fr

  9. Lithium as an adjunct to radioiodine therapy in Graves' disease for prolonging the intrathyroidal effective half-life of radioiodine. Useful or not?

    Energy Technology Data Exchange (ETDEWEB)

    Dunkelmann, S.; Kuenstner, H.; Nabavi, E.; Eberlein, U.; Groth, P.; Schuemichen, C. [Rostock Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin, Zentrum fuer Radiologie

    2006-07-01

    Aim: Evaluation of intrathyroidal kinetics of radioiodine with and without lithium as adjunct with respect to the increase in radiation dose delivered to the thyroid. Patients, methods: 267 patients in three groups were included in the study. Group I with 227 patients served as control group, Group II with 21 patients and Group III with 19 patients were distinguished by an intrathyroidal half-life of radioiodine below 3.5 days in the diagnostic test. Patients in Group III received 885 mg lithium carbonate a day for 2 weeks as adjunct to radioiodine therapy. Both diagnostic and therapeutic radioiodine kinetics were followed up by at least 10 uptake measurements within a minimum of 48 h. Kinetics of radioiodine were defined mathematically as balance of the thyroidal iodine intake and excretion by a two-compartment model. Results: Under therapy the maximum uptake of radioiodine was reduced by nearly 10% in all groups, in Group I, the effective half-life as well as the product of maximum uptake x effective half-life as an equivalent of radiation dose independent of thyroid volume was lowered in the same magnitude. In Group II, the energy-dose equivalent remained constant under therapy. With adjunct lithium in Group III, the effective half-life was prolonged significantly by factor 1.61{+-}0.49 and the volume-independent energy-dose equivalent by factor 1.39{+-}0.37. No severe side effects of lithium were observed. Conclusion: Using lithium as adjunct to radio-iodine therapy increases the radiation dose delivered to the thyroid by 39% on average and nearly 30% of radioiodine activity can be saved in these patients. Lithium is recommended in patients with very short effective half-life in the diagnostic test in order to reduce the activity required and whole-body radiation dose. (orig.)

  10. Effective Half-life of I-131 in Patients with Differentiated Thyroid Cancer Treated by Radioactive I-131

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seok Gun [Dankook University, Cheonan (Korea, Republic of)

    2008-12-15

    Effective half life of I-131 (T{sub eff}) in patients with differentiated thyroid cancer treated by I-131 is must-know value for dose calculation and determination of release time from isolation room. There has been no report about T{sub eff} in Koreans. Thus, author tried to measure dose rate without radiation exposure to faculty members and calculated T{sub eff}. Probe of radiation survey meter was fixed at the wall of isolation room, and body of survey meter was placed outside the room. With this simple arrangement, author could measure radiation frequently without radiation exposure to faculty members in 68 patient (F=55, M=13, age=47{+-}13.7) treated by I-131 (3.7{approx}7.4 GBq) for differentiated thyroid cancer from Jan 2006 to Dec 2006. From this data, T{sub eff}, 48 hr retention rate, and the time necessary to whole body retention of I-131 become less than 1.1 GBq were calculated. Serum creatinine levels were measured before and after thyroid hormone withdrawal. T{sub eff} was 15.4{+-}4.3 hr (9.4{approx}32.5 hr). There was a loose correlation between T{sub eff} and serum creatinine concentration (r=0.45). 48hr retention was 4.9{+-}4.2% (1{approx}23%). Time necessary to whole body retention of I-131 become less than 1.1 GBq was calculated as 47.1{+-}13.2 hr for 9.25 GBq, 42.1{+-}11.9 hr for 7.4 GBq, 35.7{+-}10.0 hr for 5.55 GBq, and 26.7{+-}7.5 hr for 3.7 GBq dose of I-131. Author successfully measured radiation dose rates in isolated patients treated by high dose of I-131 without radiation exposure to the faculty members with simple arrangement of survey meter probe. Using those data, T{sub eff} and some other indices were calculated.

  11. Determining thyroid {sup 131}I effective half-life for the treatment planning of Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Sapienza, Marcelo T.; Barberio Coura Filho, George; Buchpiguel, Carlos A. [Cancer Institute of Sao Paulo State (ICESP), Clinical Hospital, School of Medicine, University of Sao Paulo, Sao Paulo 01246-000 (Brazil); Nuclear Medicine Service, Department of Radiology, School of Medicine, University of Sao Paulo, Sao Paulo 01246-000 (Brazil); Traino, Antonio C. [Unit of Medical Physics, Azienda Ospedaliero-Universitaria Pisana, Pisa 56126 (Italy)

    2013-02-15

    Purpose: Thyroid {sup 131}I effective half-life (T{sub eff}) is an essential parameter in patient therapy when accurate radiation dose is desirable for producing an intended therapeutic outcome. Multiple {sup 131}I uptake measurements and resources from patients themselves and from nuclear medicine facilities are requisites for determining T{sub eff}, these being limiting factors when implementing the treatment planning of Graves' disease (GD) in radionuclide therapy. With the aim of optimizing this process, this study presents a practical, propitious, and accurate method of determining T{sub eff} for dosimetric purposes. Methods: A total of 50 patients with GD were included in this prospective study. Thyroidal {sup 131}I uptake was measured at 2-h, 6-h, 24-h, 48-h, 96-h, and 220-h postradioiodine administration. T{sub eff} was calculated by considering sets of two measured points (24-48-h, 24-96-h, and 24-220-h), sets of three (24-48-96-h, 24-48-220-h, and 24-96-220-h), and sets of four (24-48-96-220-h). Results: When considering all the measured points, the representative T{sub eff} for all the patients was 6.95 ({+-}0.81) days, whereas when using such sets of points as (24-220-h), (24-96-220-h), and (24-48-220-h), this was 6.85 ({+-}0.81), 6.90 ({+-}0.81), and 6.95 ({+-}0.81) days, respectively. According to the mean deviations 2.2 ({+-}2.4)%, 2.1 ({+-}2.0)%, and 0.04 ({+-}0.09)% found in T{sub eff}, calculated based on all the measured points in time, and with methods using the (24-220-h), (24-48-220-h), and (24-96-220-h) sets, respectively, no meaningful statistical difference was noted among the three methods (p > 0.500, t test). Conclusions: T{sub eff} obtained from only two thyroid {sup 131}I uptakes measured at 24-h and 220-h, besides proving to be sufficient, accurate enough, and easily applicable, attributes additional major cost-benefits for patients, and facilitates the application of the method for dosimetric purposes in the treatment planning of

  12. Measurement of the two-neutrino double-beta decay half-life of {sup 130}Te with the CUORE-0 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Alduino, C.; Avignone, F.T.; Chott, N.; Creswick, R.J.; Rosenfeld, C.; Wilson, J. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); Alfonso, K.; Hickerson, K.P.; Huang, H.Z.; Liu, X.; Trentalange, S.; Zhu, B.X. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Artusa, D.R. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Azzolini, O.; Camacho, A.; Keppel, G.; Palmieri, V.; Pira, C. [INFN-Laboratori Nazionali di Legnaro, Legnaro, Padova (Italy); Banks, T.I.; Drobizhev, A.; Freedman, S.J.; Hennings-Yeomans, R.; O' Donnell, T.; Wagaarachchi, S.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Bari, G.; Deninno, M.M. [INFN-Sezione di Bologna, Bologna (Italy); Beeman, J.W. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); Bellini, F.; Cardani, L.; Casali, N.; Cosmelli, C.; Ferroni, F. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Bersani, A.; Caminata, A. [INFN-Sezione di Genova, Genova (Italy); Biassoni, M.; Carbone, L.; Cremonesi, O.; Ferri, E.; Giachero, A.; Pessina, G.; Previtali, E.; Rusconi, C. [INFN-Sezione di Milano Bicocca, Milan (Italy); Brofferio, C.; Capelli, S.; Carniti, P.; Cassina, L.; Chiesa, D.; Clemenza, M.; Faverzani, M.; Fiorini, E.; Gironi, L.; Gotti, C.; Maino, M.; Nucciotti, A.; Pavan, M.; Pozzi, S.; Sisti, M.; Terranova, F.; Zanotti, L. [Universita di Milano-Bicocca, Dipartimento di Fisica, Milan (Italy); INFN-Sezione di Milano Bicocca, Milan (Italy); Bucci, C.; Cappelli, L.; D' Addabbo, A.; Di Vacri, M.L.; Gorla, P.; Pattavina, L.; Pirro, S. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Canonica, L. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Massachusetts Institute of Technology, Cambridge, MA (United States); Cao, X.G.; Fang, D.Q.; Ma, Y.G.; Wang, H.W.; Zhang, G.Q. [Chinese Academy of Sciences, Shanghai Institute of Applied Physics, Shanghai (China); Copello, S.; Di Domizio, S.; Fernandes, G.; Marini, L.; Pallavicini, M. [INFN-Sezione di Genova, Genova (Italy); Universita di Genova, Dipartimento di Fisica, Genova (Italy); Cushman, J.S.; Davis, C.J.; Heeger, K.M.; Lim, K.E.; Maruyama, R.H. [Yale University, Department of Physics, New Haven, CT (United States); Dafinei, I.; Morganti, S.; Mosteiro, P.J.; Orio, F.; Pettinacci, V.; Tomei, C.; Vignati, M. [INFN-Sezione di Roma, Rome (Italy); Dell' Oro, S. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); INFN-Gran Sasso Science Institute, L' Aquila (Italy); Feintzeig, J.; Fujikawa, B.K.; Mei, Y.; Smith, A.R. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Franceschi, M.A.; Ligi, C.; Napolitano, T.; Piperno, G. [INFN-Laboratori Nazionali di Frascati, Frascati, Rome (Italy); Giuliani, A.; Tenconi, M. [Universite Paris-Saclay, CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Orsay (France); Gladstone, L.; Leder, A.; Winslow, L.A. [Massachusetts Institute of Technology, Cambridge, MA (United States); Gutierrez, T.D. [California Polytechnic State University, Physics Department, San Luis Obispo, CA (United States); Haller, E.E. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); University of California, Department of Materials Science and Engineering, Berkeley, CA (United States); Han, K. [Yale University, Department of Physics, New Haven, CT (United States); Shanghai Jiao Tong University, Department of Physics and Astronomy, Shanghai (China); Hansen, E. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Kadel, R. [Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Kolomensky, Yu.G. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Martinez, M. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Universidad de Zaragoza, Laboratorio de Fisica Nuclear y Astroparticulas, Zaragoza (Spain); Moggi, N. [INFN-Sezione di Bologna, Bologna (Italy); Alma Mater Studiorum-Universita di Bologna, Dipartimento di Scienze per la Qualita della Vita, Bologna (Italy); Nones, C. [Service de Physique des Particules, CEA/Saclay, Gif-sur-Yvette (France); Norman, E.B.; Wang, B.S. [Lawrence Livermore National Laboratory, Livermore, CA (United States); University of California, Department of Nuclear Engineering, Berkeley, CA (United States); Ouellet, J.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Pagliarone, C.E. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Universita degli Studi di Cassino e del Lazio Meridionale, Dipartimento di Ingegneria Civile e Meccanica, Cassino (Italy); Sangiorgio, S.; Scielzo, N.D. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Santone, D. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Universita dell' Aquila, Dipartimento di Scienze Fisiche e Chimiche, L' Aquila (Italy); Singh, V. [University of California, Department of Physics, Berkeley, CA (US); Taffarello, L. [INFN-Sezione di Padova, Padova (IT); Wise, T. [Yale University, Department of Physics, New Haven, CT (US); University of Wisconsin, Department of Physics, Madison, WI (US); Woodcraft, A. [University of Edinburgh, SUPA, Institute for Astronomy, Edinburgh (GB); Zimmermann, S. [Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, CA (US); Zucchelli, S. [INFN-Sezione di Bologna, Bologna (IT); Alma Mater Studiorum-Universita di Bologna, Dipartimento di Fisica e Astronomia, Bologna (IT)

    2017-01-15

    We report on the measurement of the two-neutrino double-beta decay half-life of {sup 130}Te with the CUORE-0 detector. From an exposure of 33.4 kg year of TeO{sub 2}, the half-life is determined to be T{sub 1/2}{sup 2ν} = [8.2 ± 0.2 (stat.) ± 0.6 (syst.)] x 10{sup 20} year. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the {sup 130}Te neutrinoless double-beta decay region of interest. (orig.)

  13. Some problems of parametric neutron activation analysis based on the use of radioactive daughters of longer-lived mothers with low mother/daughter half-life ratios

    International Nuclear Information System (INIS)

    Cohen, I.M.

    2012-01-01

    The theoretical and practical aspects of the use of radioactive daughters originated from the decay of longer-lived radioactive mothers in parametric activation analysis, when the ratio: mother half-life to daughter half-life is less than 10, are discussed. The mother-daughter relationships: 47 Ca/ 47 Sc; 95 Zr/ 95 Nb; 140 Ba/ 140 La; 99 Mo/ 99m Tc and 115 Cd/ 115m In are selected as models for the study. The cases when the radionuclide of interest is formed through both direct and indirect routes are also analyzed. As illustrative example, the direct reaction and the reaction chain: 47 Ti(n,p) 47 Sc/ 46 Ca(n,γ) 47 Ca(β - ) 47 Sc are evaluated with respect to the determination of the elements involved and their reciprocal interferences. (author)

  14. Pile-up corrections for high-precision superallowed β decay half-life measurements via γ-ray photopeak counting

    Science.gov (United States)

    Grinyer, G. F.; Svensson, C. E.; Andreoiu, C.; Andreyev, A. N.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Chakrawarthy, R. S.; Finlay, P.; Garrett, P. E.; Hackman, G.; Hyland, B.; Kulp, W. D.; Leach, K. G.; Leslie, J. R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Sarazin, F.; Schumaker, M. A.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Williams, S. J.; Wong, J.; Wood, J. L.; Zganjar, E. F.

    2007-09-01

    A general technique that corrects γ-ray gated β decay-curve data for detector pulse pile-up is presented. The method includes corrections for non-zero time-resolution and energy-threshold effects in addition to a special treatment of saturating events due to cosmic rays. This technique is verified through a Monte Carlo simulation and experimental data using radioactive beams of Na26 implanted at the center of the 8π γ-ray spectrometer at the ISAC facility at TRIUMF in Vancouver, Canada. The β-decay half-life of Na26 obtained from counting 1809-keV γ-ray photopeaks emitted by the daughter Mg26 was determined to be T=1.07167±0.00055 s following a 27σ correction for detector pulse pile-up. This result is in excellent agreement with the result of a previous measurement that employed direct β counting and demonstrates the feasibility of high-precision β-decay half-life measurements through the use of high-purity germanium γ-ray detectors. The technique presented here, while motivated by superallowed-Fermi β decay studies, is general and can be used for all half-life determinations (e.g. α-, β-, X-ray, fission) in which a γ-ray photopeak is used to select the decays of a particular isotope.

  15. Towards a better prediction of peak concentration, volume of distribution and half-life after oral drug administration in man, using allometry.

    Science.gov (United States)

    Sinha, Vikash K; Vaarties, Karin; De Buck, Stefan S; Fenu, Luca A; Nijsen, Marjoleen; Gilissen, Ron A H J; Sanderson, Wendy; Van Uytsel, Kelly; Hoeben, Eva; Van Peer, Achiel; Mackie, Claire E; Smit, Johan W

    2011-05-01

    It is imperative that new drugs demonstrate adequate pharmacokinetic properties, allowing an optimal safety margin and convenient dosing regimens in clinical practice, which then lead to better patient compliance. Such pharmacokinetic properties include suitable peak (maximum) plasma drug concentration (C(max)), area under the plasma concentration-time curve (AUC) and a suitable half-life (t(½)). The C(max) and t(½) following oral drug administration are functions of the oral clearance (CL/F) and apparent volume of distribution during the terminal phase by the oral route (V(z)/F), each of which may be predicted and combined to estimate C(max) and t(½). Allometric scaling is a widely used methodology in the pharmaceutical industry to predict human pharmacokinetic parameters such as clearance and volume of distribution. In our previous published work, we have evaluated the use of allometry for prediction of CL/F and AUC. In this paper we describe the evaluation of different allometric scaling approaches for the prediction of C(max), V(z)/F and t(½) after oral drug administration in man. Twenty-nine compounds developed at Janssen Research and Development (a division of Janssen Pharmaceutica NV), covering a wide range of physicochemical and pharmacokinetic properties, were selected. The C(max) following oral dosing of a compound was predicted using (i) simple allometry alone; (ii) simple allometry along with correction factors such as plasma protein binding (PPB), maximum life-span potential or brain weight (reverse rule of exponents, unbound C(max) approach); and (iii) an indirect approach using allometrically predicted CL/F and V(z)/F and absorption rate constant (k(a)). The k(a) was estimated from (i) in vivo pharmacokinetic experiments in preclinical species; and (ii) predicted effective permeability in man (P(eff)), using a Caco-2 permeability assay. The V(z)/F was predicted using allometric scaling with or without PPB correction. The t(½) was estimated from

  16. Elimination of 5. mu. particles from the human lung

    Energy Technology Data Exchange (ETDEWEB)

    Booker, D V; Chamberlain, A C; Rundo, J; Muir, D C.F.; Thomson, M L

    1967-01-01

    Counting inhaled 5-..mu..m polystyrene particles tagged with /sup 51/Cr showed the elimination divided into a moderately rapid phase (10 to 20 hr total) and a longer phase (150 to 300 day half-period). There was no very rapid phase as described by other authors. Alveolar deposition (> 50 days half-life) was 25 to 75%. This generally correlated with inhaled volume.

  17. Half-Life of Sulfonylureas in HNF1A and HNF4A Human MODY Patients is not Prolonged as Suggested by the Mouse Hnf1a(-/-) Model.

    Science.gov (United States)

    Urbanova, Jana; Andel, Michal; Potockova, Jana; Klima, Josef; Macek, Jan; Ptacek, Pavel; Mat'oska, Vaclav; Kumstyrova, Tereza; Heneberg, Petr

    2015-01-01

    Sulfonylurea derivatives are widely used for clinical treatment of human subjects with Maturity Onset Diabetes of the Young (MODY) caused by mutations in HNF-1α or HNF-4α despite the mechanism leading to their hypersensitivity is incompletely understood. In Hnf1a(-/-) mice, serum concentrations and half-life of sulfonylurea derivatives are strongly increased. We thus hypothesized that reduced sulfonylurea derivatives clearance stands behind their therapeutic potential in human HNF1A/HNF4A MODY subjects. Single doses of 3 mg glipizide and 5 mg glibenclamide/glyburide were administered sequentially to seven HNF1A/HNF4A MODY subjects and six control individuals matched for their age, BMI and CYP2C9 genotype. Pharmacokinetic (plasma concentration levels, Cmax, tmax, t1/2, AUC) and pharmacodynamic parameters (glycemia, C-peptide and insulin plasma levels) were followed for 24 hours after drug administration. We provide the first evidence on the pharmacokinetics and pharmacodynamics of sulfonylurea derivatives in human MODY subjects. The half-life of glipizide did not change, and reached 3.8±0.7 and 3.7±1.8 h in the MODY and control subjects, respectively. The half-life of glibenclamide was increased only in some MODY subjects (t1/2 9.5±6.7 and 5.0±1.4 h, respectively). Importantly, the intra- individual responses of MODY (but control) subjects to glipizide and glibenclamide treatment were highly correlated. With regards to pharmacodynamics, we observed a differential response of control but not MODY subjects to the doses of glipizide and glibenclamide applied. We rejected the hypothesis that all human MODY-associated mutations in HNF1A / HNF4A induce changes in the pharmacokinetics of sulfonylureas in humans analogically to the Hnf1a(-/-) mouse model.

  18. Hair-to-blood ratio and biological half-life of mercury: experimental study of methylmercury exposure through fish consumption in humans.

    Science.gov (United States)

    Yaginuma-Sakurai, Kozue; Murata, Katsuyuki; Iwai-Shimada, Miyuki; Nakai, Kunihiko; Kurokawa, Naoyuki; Tatsuta, Nozomi; Satoh, Hiroshi

    2012-02-01

    The hair-to-blood ratio and biological half-life of methylmercury in a one-compartment model seem to differ between past and recent studies. To reevaluate them, 27 healthy volunteers were exposed to methylmercury at the provisional tolerable weekly intake (3.4 µg/kg body weight/week) for adults through fish consumption for 14 weeks, followed by a 15-week washout period after the cessation of exposure. Blood was collected every 1 or 2 weeks, and hair was cut every 4 weeks. Total mercury (T-Hg) concentrations were analyzed in blood and hair. The T-Hg levels of blood and hair changed with time (p < 0.001). The mean concentrations increased from 6.7 ng/g at week 0 to 26.9 ng/g at week 14 in blood, and from 2.3 to 8.8 µg/g in hair. The mean hair-to-blood ratio after the adjustment for the time lag from blood to hair was 344 ± 54 (S.D.) for the entire period. The half-lives of T-Hg were calculated from raw data to be 94 ± 23 days for blood and 102 ± 31 days for hair, but the half-lives recalculated after subtracting the background levels from the raw data were 57 ± 18 and 64 ± 22 days, respectively. In conclusion, the hair-to-blood ratio of methylmercury, based on past studies, appears to be underestimated in light of recent studies. The crude half-life may be preferred rather than the recalculated one because of the practicability and uncertainties of the background level, though the latter half-life may approximate the conventional one.

  19. CYP2C8 activity recovers within 96 hours after gemfibrozil dosing: estimation of CYP2C8 half-life using repaglinide as an in vivo probe.

    Science.gov (United States)

    Backman, Janne T; Honkalammi, Johanna; Neuvonen, Mikko; Kurkinen, Kaisa J; Tornio, Aleksi; Niemi, Mikko; Neuvonen, Pertti J

    2009-12-01

    Gemfibrozil 1-O-beta-glucuronide is a mechanism-based inhibitor of cytochrome P450 2C8. We studied the recovery of CYP2C8 activity after discontinuation of gemfibrozil treatment using repaglinide as a probe drug, to estimate the in vivo turnover half-life of CYP2C8. In a randomized five-phase crossover study, nine healthy volunteers ingested 0.25 mg of repaglinide alone or after different time intervals after a 3-day treatment with 600 mg of gemfibrozil twice daily. The area under the plasma concentration-time curve (AUC) from time 0 to infinity of repaglinide was 7.6-, 2.9-, 1.4- and 1.0-fold compared with the control phase when it was administered 1, 24, 48, or 96 h after the last gemfibrozil dose, respectively (P gemfibrozil). Thus, a strong CYP2C8 inhibitory effect persisted even after gemfibrozil and gemfibrozil 1-O-beta-glucuronide concentrations had decreased to less than 1% of their maximum (24-h dosing interval). In addition, the metabolite to repaglinide AUC ratios indicated that significant (P gemfibrozil administration. Based on the recovery of repaglinide oral clearance, the in vivo turnover half-life of CYP2C8 was estimated to average 22 +/- 6 h (mean +/- S.D.). In summary, CYP2C8 activity is recovered gradually during days 1 to 4 after gemfibrozil discontinuation, which should be considered when CYP2C8 substrate dosing is planned. The estimated CYP2C8 half-life will be useful for in vitro-in vivo extrapolations of drug-drug interactions involving induction or mechanism-based inhibition of CYP2C8.

  20. Propose of a model for dose and hazard calculation due the Rn-222, Rn-220 and its short half-life daugthers inhalation

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1982-01-01

    The compartimental dosimetric model is used to simulate, by computer, the interactions of the inhalated radon atom radiations and its short half-life daugthers with cells. The metabolic trajectory of these radionuclides is described by differential equations of continuous medium dynamics, where the elements transform by radioactive decay. This work permits to determine the individual retenction function, beeing useful in radioprotection routines or emergence situations. The results of internal dosimetry are consistent with the new I.C.R.P. - 32 international recommendations. (L.C.) [pt

  1. Proposal of a new model for dose calculation due to the inhalation of Ru-222, Ru-220 and their sons with brief half-life

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1982-06-01

    The consequences of the radiation interactions upon the human body are studied. In order to simulate by computer the radiation interaction of the atoms of radon and thoron atoms and their Sons with a brief half life inhaled with the cells, the compartimental dosimetric model is used. The metabolic pathway of those radionuclides is described by continuous medium dynamic differential equation. The energy transfer processes are seen in details. The individual retention function is determined by bio-analysis. The results of internal dosimetry are consistents with the new international recommendations from ICRP-32. (L.F.S.) [pt

  2. Uptake and elimination of radiotungsten in black bullheads

    International Nuclear Information System (INIS)

    Reed, J.R.

    1975-01-01

    Black bullheads, Ictalurus melas (Rafinesque), accumulated radiotungsten from food and water. Whole-body activity reached a plateau after the fish had been in tagged water 4 days (mean temperature 154 0 C). Whole-body elimination of radiotungsten varied with the method of uptake. Fish that had accumulated radiotungsten from water had a single exponential component of elimination with a biological half-life of 2.75 days. Fish that had received radioisotope in a single feeding lost activity at two rates; one component had a biological half-life of 14 hr and the second 6 days. The bone, skin, flesh, blood, and gills contained the greatest percentages of whole-body activity after 1 day of uptake from tagged water; after 8 days, the flesh, gills, bone, and gut together contained 78.6 percent of the total activity. The bone had the longest biological half-life (8.0 days) of the tissues examined and contained 69.8 percent of the whole-body acitivty after 16 days of elimination

  3. Half-life and mass measurement of the short-lived {sup 215}Po isotope (1.78 ms) at the FRS ion catcher

    Energy Technology Data Exchange (ETDEWEB)

    Rink, Ann-Kathrin; Bergmann, Julian; Ebert, Jens; Hornung, Christine; Miskun, Ivan; Reiter, Moritz P. [Justus-Liebig Universitaet Giessen (Germany); Ayet San Andres, Samuel; Dickel, Timo; Plass, Wolfgang R.; Scheidenberger, Christoph [Justus-Liebig Universitaet Giessen (Germany); GSI, Darmstadt (Germany); Geissel, Hans; Purushothaman, Sivaji [GSI, Darmstadt (Germany)

    2016-07-01

    At the Low-Energy Branch (LEB) of the Super-FRS at FAIR, precision experiments with exotic nuclei will be performed using ion traps and lasers. The nuclei will be produced at relativistic energies, slowed down, thermalised in a cryogenic stopping cell (CSC) and made available to various experiments. The thermalisation is a challenging task because of the large energy straggling of the nuclei after production, which requires a stopping cell with large areal densities. Also, the process needs to be performed on a millisecond time scale in order to give access to short-lived nuclides. This method has already been successfully applied at the FRS Ion Catcher at GSI using a prototype CSC. Recently the potential of the method has been demonstrated by the mass and half-life measurement of the {sup 215}Po nuclide with a half-life of 1.78 ms only. The multiple-reflection time-of-flight mass spectrometer at the FRS Ion Catcher has been used to determine the mass to a sub-ppm accuracy and to provide a mass-selected beam for alpha spectroscopy. Furthermore, experiments have been performed with the prototype CSC in order to test novel concepts to be used with the final version of the CSC for the LEB.

  4. New AMS method to measure the atom ratio {sup 146}Sm/{sup 147}Sm for a half-life determination of {sup 146}Sm

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, N. [Tandem Accelerator Complex, Research Facility Center for Science and Technology, University of Tsukuba (Japan); Paul, M., E-mail: paul@vms.huji.ac.il [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Alcorta, M. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Bowers, M.; Collon, P. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556-5670 (United States); Deibel, C.M. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 46624 (United States); DiGiovine, B. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Goriely, S. [Universite Libre de Bruxelles, CP-226, Brussels 1050 (Belgium); Greene, J.P.; Henderson, D.J.; Jiang, C.L. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Kashiv, Y. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556-5670 (United States); Kay, B.P.; Lee, H.Y.; Marley, S.T. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Nakanishi, T. [Faculty of Chemistry, Institute of Science and Engineering, Kanazawa University (Japan); Pardo, R.C.; Patel, N.; Rehm, K.E. [Physics Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Robertson, D. [Department of Physics, University of Notre Dame, Notre Dame, IN 46556-5670 (United States); and others

    2013-01-15

    The extinct p-process nuclide {sup 146}Sm (t{sub 1/2} = 103 {+-} 5 Myr) is known to have been present in the Early-Solar System and has been proposed as an astrophysical chronometer. {sup 146}Sm is also intensely used to date meteorite and planetary differentiation processes, enhancing the importance of an accurate knowledge of the {sup 146}Sm half-life. We are engaged in a new determination of the {sup 146}Sm half-life in which the {sup 146}Sm/{sup 147}Sm atom ratio is determined by accelerator mass spectrometry at the ATLAS facility of Argonne National Laboratory. In order to reduce systematic errors in the AMS determination of the {sup 146}Sm/{sup 147}Sm ratios (in the range of 10{sup -7}-10{sup -9}), {sup 146}Sm and {sup 147}Sm ions were alternately counted in the same detector in the focal plane of a gas-filled magnet, respectively in continuous-wave and attenuated mode. Quantitative attenuation is obtained with the 12 MHz pulsed and ns-bunched ATLAS beam by chopping beam pulses with an RF sweeper in a ratio (digitally determined) down to 1:10{sup 6}. The experiments and preliminary results are discussed.

  5. Increased volume of distribution for recombinant activated factor VII and longer plasma-derived factor VII half-life may explain their long lasting prophylactic effect.

    Science.gov (United States)

    Mathijssen, Natascha C J; Masereeuw, Rosalinde; Holme, Pal Andre; van Kraaij, Marian G J; Laros-van Gorkom, Britta A P; Peyvandi, Flora; van Heerde, Waander L

    2013-08-01

    Prophylaxis with plasma-derived or recombinant activated factor VII is beneficial in severe factor VII deficiency. To understand why prophylactic treatment with both products is efficacious, we conducted a pharmacokinetic study. Ten factor VII deficient patients were treated with either recombinant activated (20 μg/kg) or plasma-derived (25 IU/kg) factor VII in a cross-over design. Pharmacokinetic parameters were analyzed through activated factor VII activity, factor VII clotting activity, and factor VII antigen levels on depicted time points. Factor VII activity half-lifes, determined by non-compartmental and one-compartmental analysis (results in brackets), were shorter for recombinant activated (1.4h; 0.7h) than for plasma-derived factor VII (6.8h; 3.2h); both recombinant activated (5.1h; 2.1h and plasma-derived factor VII (5.8h; 3.2h) resulted in longer half-lives of factor VII antigen. Activated factor VII half-lives (based on activated factor VII activity levels) were significantly higher compared to factor VII clotting activity (1.6h; 0.9h). Volumes of distribution were significantly higher for activated factor VII (236 ml/kg; 175 ml/kg, measured by activated factor VII) as compared to plasma-derived factor VII (206 ml/kg; 64 ml/kg, measured by factor FVII activity), suggesting a plasma- and extracellular fluid distribution for recombinant activated factor VII. Recombinant activated factor VII showed significantly shorter half-lifes than plasma-derived factor VII. Volumes of distribution were significantly higher for treatment with recombinant activated factor VII. The longer half-life for plasma-derived factor VII, compared to recombinant activated factor VII, and the increased volume of distribution for recombinant activated factor VII, compared to plasma-derived factor VII may further elucidate the beneficial effect of prophylactic treatment of both products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Purification of a 166mHo solution by successive high-performance liquid chromatography and gravitational chromatography for half-life determination

    International Nuclear Information System (INIS)

    Florence Gueguen; Helene Isnard; Carole Bresson; Celine Caussignac; Guillaume Stadelmann; Anthony Nonell; Sebastien Mialle; Karsten Kossert; Frederic Chartier

    2014-01-01

    A methodology to purify a 166m Ho solution has been developed by a combination of activity and mass concentration measurements in order to further determine the 166m Ho half-life. The isobaric interference at m/q ≃ 166 requires Ho purification from non-natural Er with a high purification degree due to the large amount of Ho as opposed to Er. The Ho/Er separation was achieved using high-performance liquid chromatography on a semi-preparative column followed by purification on gravitational chromatography. The efficiency of the separation was evaluated after precise determination of the Er isotopic composition. The purification methodology enabled to separate Ho from Er. (author)

  7. The short half-life descendents from radon measured in Sao Jose dos Campos and Cachoeira Paulista, Brazil, and its correlation with meteorological data

    International Nuclear Information System (INIS)

    Andrade Marinho, E.V. de.

    1985-09-01

    The correlations between the activity of the short half-life radon decay products in the low atmosphere and the meterological parameters, measuring the atmospheric polonium 214 are studied. The aerosols were collected on membrane filters and analysed by alpha spectrometry. Measurements have been made in Sao Jose dos Campos and Cachoeira Paulista, in Brazil. At S. Jose dos Campos the influence of the pluviometry on the concentration of atmospheric Po 214 has been analysed, showing that high activity correspond to low pluviometry and inversely, low activities correspond to high pluviometry. At Cachoeira Paulista, the variation in the atmospheric Po 214 activity in corresation with the air stability, measured, showing the accumulation of radioactive aerosols during the greater stability in the the lower atmospheric layers, was studied. (author) [pt

  8. The analysis of predictability of α-decay half-life formulae and the α partial half-lives of some exotic nuclei

    International Nuclear Information System (INIS)

    Dasgupta-Schubert, N.; Reyes, M.A.; Tamez, V.A.

    2009-01-01

    The predictabilities of the three α-decay half-life formulae, the Royer GLDM, the Viola-Seaborg and the Sobiczewski-Parkhomenko formulae, have been evaluated by developing a method based on the ansatz of standard experimental benchmarking. The coefficients of each formula were re-derived using the reliable data of the α -standards nuclei. The modified formulae that resulted were used to evaluate the accuracies of the formulae towards the prediction of half-lives of a set of nuclides with well-studied α spectroscopic data as well as a set of exotic α emitters. Further, a simple linear optimisation of the modified formulae allowed adjustments for the insufficient statistics of the primary data set without changing the modified formulae. While the three modified formulae showed equivalent results for all the medium heavy nuclei except the odd-odd, the modified GLDM showed relatively the best figures of merit for the odd-odd and superheavy nuclides. (orig.)

  9. Half-life Measurements of {sup 6}He, {sup 16}N, {sup 19}O, {sup 20}F, {sup 28}Al, {sup 77m}Se and {sup 1}

    Energy Technology Data Exchange (ETDEWEB)

    Konijn, J; Malmskog, S

    1962-06-15

    The half-life of different isotopes, activated by neutrons in the reactor R2-0 by means of a pneumatic rabbit, have been measured with a pulse height analyzer working in its multiscale mode of operation. A Nal(Tl)-scintillation spectrometer was used as detector. Least squares analysis calculated by the Mercury computer were performed for each measurement. The following weighted mean values of the half-lives are obtained {sup 6}He: 0.862 {+-} 0.017 sec.; {sup 16}N: 7.31 {+-} 0.04 sec.; {sup 19}O: 29.1 {+-} 0.3 sec.; {sup 20}F: 11.56 {+-} 0.05 sec.; {sup 28}Al: 2.31 {+-} 0.01 min.; {sup 77m}Se: 18.83 - 0.04 sec.; and {sup 110}Ag: 24.42 {+-} 0.14 sec.

  10. The effective and environmental half-life of {sup 137}Cs at Coral Islands at the former US nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Robison, William L. E-mail: robison1@llnl.gov; Conrado, Cynthia L.; Bogen, Kenneth T.; Stoker, A. Carol

    2003-07-01

    The United States (US) conducted nuclear weapons testing from 1946 to 1958 at Bikini and Enewetak Atolls in the northern Marshall Islands. Based on previous detailed dose assessments for Bikini, Enewetak, Rongelap, and Utirik Atolls over a period of 28 years, cesium-137 ({sup 137}Cs) at Bikini Atoll contributes about 85-89% of the total estimated dose through the terrestrial food chain as a result of uptake of {sup 137}Cs by food crops. The estimated integral 30, 50, and 70-year doses were based on the radiological decay of {sup 137}Cs (30-year half-life) and other radionuclides. However, there is a continuing inventory of {sup 137}Cs and {sup 90}Sr in the fresh water portion of the groundwater at all contaminated atolls even though the turnover rate of the fresh groundwater is about 5 years. This is evidence that a portion of the soluble fraction of {sup 137}Cs and {sup 90}Sr inventory in the soil is lost by transport to groundwater when rainfall is heavy enough to cause recharge of the lens, resulting in loss of {sup 137}Cs from the soil column and root zone of the plants. This loss is in addition to that caused by radioactive decay. The effective rate of loss was determined by two methods: (1) indirectly, from time-dependent studies of the {sup 137}Cs concentration in leaves of Pisonia grandis, Guettarda specosia, Tournefortia argentea (also called Messerschmidia), Scaevola taccada, and fruit from Pandanus and coconut trees (Cocos nucifera L.), and (2) more directly, by evaluating the {sup 137}Cs/{sup 90}Sr ratios at Bikini Atoll. The mean (and its lower and upper 95% confidence limits) for effective half-life and for environmental-loss half-life (ELH) based on all the trees studied on Rongelap, Bikini, and Enewetak Atolls are 8.5 years (8.0 years, 9.8 years), and 12 years (11 years, 15 years), respectively. The ELH based on the {sup 137}Cs/{sup 90}Sr ratios in soil in 1987 relative to the{sup 137}Cs/{sup 90}Sr ratios at the time of deposition in 1954 is less

  11. Investigation concerning the relative formation rate and half-life time of short-lived nuclides with a fast conveyor tube system

    International Nuclear Information System (INIS)

    Kreiner, H.J.

    1976-01-01

    Since the installation of the 'Ultrafast Rabbit System' at the FRN in end of 1974, some research was started concerning the possibility of neutron activation analysis of short-lived nuclides (0.02 1/2 < 1 s) and measurements of short-lived fission products of U-235 and Pu-239. One of the results of the investigations is a more exact gamma-energy determination of the 0.8 s Cl-38m with 671.33 keV. In NAA it was possible to reach a sensitivity for lead and boron near 2 μg per sample respectively 10 ppm. In measurements of light fission products 0.1 - 8s after a pulse irradiation some differences of the relative formation rate and half-life in the region of A approximately 100 were found in comparison to literature. For example a strong build-up could be seen measuring the gamma-energy of 276.1 keV that belongs to Nb-101. Therefore we suppose the existence of an isomeric state of Nb-101. In comparison to our own results of yield ratio of the Pu- and U-fission products a good agreement with known data was found. Furthermore the measuring method gives the possibility of coordination of unknown gamma-lines to nuclides using the rate of formation, the half-life, the yield ratio between U and Pu and the build-up factor. That could be verified in some cases, e.g. Nb-103 and Sr-96. (author)

  12. Study of niobium isotopes having excess neutrons and a short half-life; Etude des isotopes du niobium excedentaires en neutrons et de courte periode

    Energy Technology Data Exchange (ETDEWEB)

    Huebenthal, K [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-02-01

    By irradiating Mo with 14 MeV neutrons isomers have been found for {sup 98}Nb (2.8 s half-life) {sup 99}Nb (9 s) and {sup 100}Nb (2.4 s). No isomer of this type seems to exist for {sup 96}Nb. Rapid separation methods are developed for isolating {sup 98}Zr from fission products, and for separating Zr and Nb. The half-life of {sup 98}Zr is measured (31 s) and the formation of {sup 98}Nb (2.8 s) from {sup 98}Zr (31 s) is shown by milking. Rough {beta} and {gamma} measurements of these nuclei are described. The {gamma} spectrum of {sup 98}Nb (51 mn) is studied with a high-resolution Ge/Li - detector. (authors) [French] Des irradiations des isotopes de molybdene avec des neutrons de 14 MeV ont mis en evidence l'existence des isomeres de {sup 98}Nb (periode 2.8 s) {sup 99}Nb (9 s) et {sup 100}Nb (2.4 s). Pour le {sup 96}Nb un isomere de ce type ne semble pas exister. Des methodes rapides de separation sont mises au point pour isoler le zirconium 98 des produits de fission, et pour separer ensuite le niobium du zirconium. La periode du {sup 98}Zr est de 3l s, et on demontre la formation du {sup 98}Nb (2.8 s) a partir du Zr (31 s). Ces corps sont etudies sommairement en spectroscopie {beta} et {gamma}. Le spectre gamma de {sup 98}Nb (periode 51 mn) est etudie avec un detecteur Ge/Li de haute resolution. (auteurs)

  13. Determination of half life of the pesticides chlorpyrifos (14C) in an agricultural soil of the VI region by means of the using isotopic techniques

    International Nuclear Information System (INIS)

    Camarda Rojas, Gabriela Paz

    2005-01-01

    Chlorpyrifos is an organophosphorus insecticide widely used in Chilean agriculture in the control of plagues of insects in soil and several crops. From an environmental point of view, to know the behavior and fate of Chlorpyrifos under different moisture regimes in soil is important because it contributes to optimize its use, assuring that collateral effects do not take place inside or outside the application area and in addition it specifies the optimal conditions of application to obtain better results in the treatment with the land insecticide. In this work it was studied the half life of Chlorpyrifos ( 14 C) in an agricultural soil of VI Region, by means of the use of Isotopic techniques, under two moisture regimes of 50 and 75% of the Field Capacity. The ground samples were fortified with doses of 10 mg/Kg and incubated to 20 o C and in absence of light. The dissipation of Chlorpyrifos in soil was determined during 110 days of test, through the quantification of remaining 14 CO 2 by liquid scintillation counting. Results show temporary differences in the half life for different moisture regimes, with T 1/2 of 21 and 28 days for the soil to 75 and 50% of the Field Capacity, respectively. It was studied the factors related to soil and plaguicide that could affect speed of degradation, either accelerating or inhibiting the process of dissipation of Chlorpyrifos, under the described moisture regimes. The results indicated that the fast degradation of the insecticide organophosphorus in the soil to 75% of the CC is product of biotic and abiotic processes. Between the abiotic processes the neutral hydrolysis constituted the principal route of dissipation, mainly due to the moisture content and pH presented in soil (pH 7,2). Nevertheless, factors as the high content of organic matter of the soil, low water solubility, high coefficient of adsorption and bond p=S of the Chlorpyrifos, they suggest the sorption process would inhibit hydrolysis, slowing down the

  14. Metabolically stable bradykinin B2 receptor agonists enhance transvascular drug delivery into malignant brain tumors by increasing drug half-life

    Directory of Open Access Journals (Sweden)

    Glen Daniel

    2009-05-01

    -lysine-bradykinin and labradimil increased the blood half-life of Gd-DTPA sufficiently enough to increase significantly the tumor tissue Gd-DTPA area under the time-concentration curve. Conclusion Metabolically stable bradykinin B2 receptor agonists, methionine-lysine-bradykinin and labradimil, enhance the transvascular delivery of small chemotherapy drugs across the BBTB of malignant gliomas by increasing the blood half-life of the co-infused drug. The selectivity of the increase in drug delivery into the malignant glioma tissue, but not into normal brain tissue or skeletal muscle tissue, is due to the inherent porous nature of the BBTB of malignant glioma microvasculature.

  15. Half-Life Studies of Radiocaesium in Humans; Etudes sur la Periode de Radiocesium chez l'Homme; 0418 0421 0421 041b 0415 0414 ; Estudio sobre el Periodo Biologico del Radiocesio en el Hombre

    Energy Technology Data Exchange (ETDEWEB)

    Naversten, Y.; Liden, K. [Radiation Physics Department, University of Lund (Sweden)

    1964-11-15

    The retention of caesium-137 in humans has been studied in several cases. Two adult men were intravenously administered a small quantity of caesium-137. They were followed about 300 days by frequent whole-body counting and with excreta collection during the initial period. The retention decreased as a sum of two exponentials. The slowest compartment decreased with a half-life of about 75 d. One of them was also given caesium-137 orally 2 years later with the same excretion pattern obtained as after intravenous injection. The excretion rate of caesium-137 has also been studied in a different way for large groups of men, women and children through comparison with diet data. From a group of 10 people, voluntarily changing their diet, the average excretion rate could be calculated from whole-body counting at an interval of six weeks. The excretion also has been obtained from a study on two people after an oral administration of caesium-132. Detailed results on these studies will be given particularly with respect to the elimination rate of caesium, i.e. the biological half-life and its variation with sex and age. On the average, half-lives ranging from 30 to 90 d have been obtained. (author) [French] La retention de cesium 137 chez l'homme a ete etudiee sur plusieurs sujets. Ainsi, on a administre a deux hommes adultes, par voie intraveineuse, une petite quantite de cesium 137. On les a suivis pendant 300 j environ en faisant de frequents dosages de l'activite du corps et en recueillant les excreta au debut de la periode. La fonction qui representait la decroissance de la retention est une somme de deux exponentielles. La fraction qui decroissait le plus lentement avait une periode d'environ 75 j. Deux ans plus tard, on a administre du cesium 137 a un des deux sujets, par voie buccale, et on a obtenu le meme regime d'elimination qu'apres l'injection intraveineuse. On a aussi etudie le taux d'elimination de cesium 137 par une methode differente pour des groupes

  16. Precision measurement of the half-life and branching ratio of the T=1/2 mirror $\\beta$-decay of $^{37}$K

    CERN Multimedia

    We propose to study the T=1/2 mirror $\\beta$-decay of $^{37}$K. Nuclear mirror $\\beta$-decay is a competitive means to test the electroweak model by means of the high-precision measurement of V$_{ud}$ element of the CKM quark mixing matrix. One key ingredient to obtain V$_{ud}$ is the force of the transition, Ft, which has to be determined with a relative precision below 10$^{−3}$. This quantity is related to the half-life T$_{1/2}$ of the decaying nucleus, the branching ratio BR for this decay and the mass difference between the mother and daughter nucleus (Q value). Another important feature is the mixing ratio $\\rho$ between the Fermi and the Gamow-Teller character of the transition. In most cases, $\\rho$ is the major contributor to the uncertainty on Ft. Available data concerning T$_{1/2}$ and BR of $^{37}$K suffer from a lack of precision that will be easily reduced by a dedicated experiment.

  17. New limit for the half-life of double beta decay of {sup 94}Zr to the first excited state of {sup 94}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Dokania, N.; Nanal, V.; Gupta, G.; Pillay, R.G.; Ghosh, C. [Tata Institute of Fundamental Research, Department of Nuclear and Atomic Physics, Mumbai (India); Pal, S. [Tata Institute of Fundamental Research, Pelletron Linac Facility, Mumbai (India); Rath, P.K. [University of Lucknow, Department of Physics, Lucknow (India); Tretyak, V.I. [Institute for Nuclear Research, Kyiv (Ukraine); Garai, A.; Krishnamoorthy, H. [Tata Institute of Fundamental Research, India-based Neutrino Observatory, Mumbai (India); Homi Bhabha National Institute, Mumbai (India); Raina, P.K. [Indian Institute of Technology, Department of Physics, Rupnagar (India); Bhushan, K.G. [Bhabha Atomic Research Centre, Technical Physics Division, Mumbai (India)

    2017-04-15

    Neutrinoless double beta decay is a phenomenon of fundamental interest in particle physics. The decay rates of double beta decay transitions to the excited states can provide input for Nuclear Transition Matrix Element calculations for the relevant two neutrino double beta decay process. It can be useful as supplementary information for the calculation of Nuclear Transition Matrix Element for the neutrinoless double beta decay process. In the present work, double beta decay of {sup 94}Zr to the 2{sup +}{sub 1} excited state of {sup 94}Mo at 871.1 keV is studied using a low background ∝ 230 cm{sup 3} HPGe detector. No evidence of this decay was found with a 232 g.y exposure of natural zirconium. The lower half-life limit obtained for the double beta decay of {sup 94}Zr to the 2{sup +}{sub 1} excited state of {sup 94}Mo is T{sub 1/2}(0ν + 2ν) > 3.4 x 10{sup 19} y at 90% C.L., an improvement by a factor of ∝ 4 over the existing experimental limit at 90% C.L. The sensitivity is estimated to be T{sub 1/2} (0ν + 2ν) > 2.0 x 10{sup 19} y at 90% C.L. using the Feldman-Cousins method. (orig.)

  18. Precision measurement of the half-life and the $\\beta$-decay Q value of the superallowed 0$^{+}\\rightarrow$ 0$^{+}\\beta$-decay of $^{38}$Ca

    CERN Multimedia

    2002-01-01

    We propose to study the $\\beta$-decay of $^{38}$Ca. In a first instance, we intend to perform a high-precision study of the half-life of this nucleus as well as a measurement of its $\\beta$-decay Q-value with ISOLTRAP. At a later stage, we propose to study its decay branches to determine the super-allowed branching ratio with high precision. These measurements are essential to improve our understanding of the theoretical corrections (in particular the $\\delta$c correction factor) needed to calculate the universal Ft value from the ft value determined for individual nuclei. For this nucleus, the correction factor is predicted to increase significantly as compared to the nine well-studied nuclei between $^{10}$C and $^{54}$Co and the model calculations used to determine the corrections, in particular the shell-model calculations, are well under control in this mass region. Therefore, the T$_{Z}$= -1 nuclei between A=18 and A=38 are ideal test cases for the correction factors which limit today the precision on t...

  19. Effective half-life of sup 131 I during treatment of autonomous thyroid disease. Untersuchungen zur effektiven Halbwertszeit des sup 131 J bei der Radiojodbehandlung der Schilddruesenautonomie

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, B.; Bares, R.; Buell, U. (Technische Hochschule Aachen (Germany, F.R.). Klinik fuer Nuklearmedizin)

    1991-06-01

    In order to compute effective half-life of {sup 131}I after application of therapeutic doses (T{sub eff}), the time course of whole-body radioactivity was evaluated retrospectively in 115 patients with benign thyroid diseases (multinodular autonomous adenoma, solitary autonomous adenoma or Graves' disease). Because of a large overlap of T{sub eff} in the various diseases analyzed, courses of all patients who did (group Ts, 24 cases) or did not (group kTs, 91 cases) receive antithyroid drugs during therapy were summarized. In group Ts a mean T{sub eff} of 5.0+-0.9 d was found which was significantly (p<0.01) lower than the mean T{sub eff} of 6.3+-0.9 d in group kTs. We believe that the mean T{sub eff} is a practical alternative in radioiodine dosimetry if an exact determination of T{sub eff} cannot be performed because of shortage of time. (orig.).

  20. Studies on the mechanism of the epileptiform activity induced by U18666A. II. concentration, half-life and distribution of radiolabeled U18666A in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Cenedella, R.J.; Sarkar, C.P.; Towns, L.

    1982-06-01

    The concentration, half-life, and distribution in brain of U18666A, a drug that can drastically alter cerebral lipids and induce a chronic epileptiform state, was determined following both acute and chronic drug administration. U18666A specifically labeled with tritium was prepared by custom synthesis. Brain levels of 1 x 10(-6)M and higher were reached soon after giving an acute 10-mg/kg dose (i.p. or s.c.) of U18666A containing 7-/sup 3/H-U18666A of known specific activity. A steady state concentration of 1 to 2 x 10(-6)M was reached with chronic injection of 10 mg/kg every 4th day, a treatment schedule that results in altered brain lipids and induction of epilepsy if begun soon after birth. The disappearance of U18666A from both brain and serum was described by two similar biexponential processes, a brief rapid clearance (t1/2 . 10 h) and a sustained and much slower one (t1/2 . 65 h). Brain levels of the drug were about 10 times higher than serum at all times examined. Few differences were seen in the regional distribution of radiolabeled drug in brain as determined by both direct analysis and by autoradiographic examination; but the drug did concentrate in lipid-rich subcellular fractions. For example, the synaptosome and myelin fractions each contained about 25-35% of both the total /sup 3/H-labeled drug and total lipid in whole brain. The lipid composition of these fractions was drastically altered in treated animals. In conclusion, the chronic epileptiform state induced by U18666A does not appear to involve localization of the drug in a specific brain region or particular cell type. Rather, the condition could involve localization of the drug in lipid-rich membranes and marked changes in the composition of these membranes.

  1. Anti-restenotic effect of copper-62 liquid-filled balloon in porcine coronary arteries: novel use of a short half-life positron emitter

    International Nuclear Information System (INIS)

    Chan, Rosanna C.; Lacy, Jeffrey L.; Bhargava, Balram; Collins, Sara D.; Cates, Pamela; Cottin, Yves; Kollum, Marc; Yang, Nathan; Haynes, Neal G.; Martin, Christopher S.; Nayak, Nisha; Vodovotz, Yoram; Kim, Han-Soo; Waksman, Ron

    2000-01-01

    Purpose: To determine the efficacy of the use of copper-62, a positron emitter with a half-life of 9.7 minutes, as an intracoronary brachytherapy (IRBT) source in the prevention of neointima formation (NF) following overstretch balloon injury (BI) in the porcine model. Methods and Materials: Sixteen swine were treated after BI to their left anterior descending (LAD), left circumflex (LCX), and/or right coronary artery (RCA). Twelve of the injured arteries received placebo and 10 received 25 Gy, delivered to 0.5 mm from the surface of the treatment balloon filled with liquid 62 Cu. Dosimetry was based on Monte Carlo calculations. Two weeks after treatment, the animals were sacrificed, and the treated coronaries were perfusion-fixed and stained. Intimal area (IA) and medial fracture length (FL) were analyzed by computer-aided histomorphometry. Results: The ( 62 Zn/ 62 Cu) generator, together with a rapid concentration process, was successful in delivering the short-lived 62 Cu at the high concentration required for intravascular brachytherapy (IVBT). The fracture length in the two groups was similar (2.10 ± 0.57; 2.02 ± 0.77; p = NS). Arteries studied showed significant reduction in NF (IA: 0.23 ± 0.47 mm 2 vs. 1.08 ± 0.57 mm 2 ; p 62 Cu as an IVBT source is safe and feasible. All 16 swine tolerated the treatment well with no radiation-induced side effects or symptoms throughout the 2-week period. The isotope delivered the dose necessary to inhibit NF in the porcine coronary BI model

  2. Distribution of ascorbate-2-sulfate and distribution, half-life and turnover rates of [1-14C]ascorbic acid in rainbow trout

    International Nuclear Information System (INIS)

    Tucker, B.W.; Halver, J.E.

    1984-01-01

    Rainbow trout (250 g) were maintained at 15 degrees C for 3 months on a low ascorbic acid diet, given [1- 14 C]ascorbic acid by gavage, then fed the NAS/NRC requirement 12 times per week. Total urine, fecal water and branchial water were collected daily from five fish placed in metabolism chambers for four successive 5-day periods. Tissue samples were analyzed for 14 C, ascorbic acid (C1) and ascorbate-2-sulfate (C2). Excretion analysis indicated t1/2 . 42 days. After 20 days, the feeding schedule was changed to 3 times per week. Fish fed 14 C were sampled after 1, 2, 3 and 4 months. The half-life in each organ except brain was inversely proportional to the dietary level of ascorbate. Concentrations of C1 and C2 in the various tissues reflected dietary intake of vitamin C. Total C (CT . C1 + C2) levels were maintained in the liver even with the low vitamin C diet. Estimates of body pool for C1 are 27-29 mg/kg. At the higher ascorbate intake CT was 92-114 mg/kg, but decreased by 34% at the lower feeding rate to 51-62 mg/kg. Data indicate that there are two or more body pools that include a store of C2, which is readily interconverted in metabolizing tissues to and from C1. Since air and water stable C2 is antiscorbutic for fish, it is the preferred form of ascorbate for fish feeds

  3. Effect of Truncating AUC at 12, 24 and 48 hr When Evaluating the Bioequivalence of Drugs with a Long Half-Life.

    Science.gov (United States)

    Moreno, Isabel; Ochoa, Dolores; Román, Manuel; Cabaleiro, Teresa; Abad-Santos, Francisco

    2016-01-01

    Bioequivalence studies of drugs with a long half-life require long periods of time for pharmacokinetic sampling. The latest update of the European guideline allows the area under the curve (AUC) truncated at 72 hr to be used as an alternative to AUC0-t as the primary parameter. The objective of this study was to evaluate the effect of truncating the AUC at 48, 24 and 12 hr on the acceptance of the bioequivalence criterion as compared with truncation at 72 hr in bioequivalence trials. The effect of truncated AUC on the within-individual coefficient of variation (CVw) and on the ratio of the formulations was also analysed. Twenty-eight drugs were selected from bioequivalence trials. Pharmacokinetic data were analysed using WinNonLin 2.0 based on the trapezoidal method. Analysis of variance (ANOVA) was performed to obtain the ratios and 90% confidence intervals for AUC at different time-points. The degree of agreement of AUC0-72 in relation to AUC0-48 and AUC0-24, according to the Landis and Koch classification, was 'almost perfect'. Statistically significant differences were observed when the CVw of AUC truncated at 72, 48 and 24 hr was compared with the CVw of AUC0-12. There were no statistically significant differences in the AUC ratio at any time-point. Compared to AUC0-72, Pearson's correlation coefficient for mean AUC, AUC ratio and AUC CVw was worse for AUC0-12 than AUC0-24 or AUC0-48. These preliminary results could suggest that AUC truncation at 24 or 48 hr is adequate to determine whether two formulations are bioequivalent. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  4. Dose-response feeding study of short chain chlorinated paraffins (SCCPs) in laying hens: effects on laying performance and tissue distribution, accumulation and elimination kinetics.

    Science.gov (United States)

    Ueberschär, Karl-Heinz; Dänicke, Sven; Matthes, Siegfried

    2007-02-01

    Technical short chain chlorinated paraffins (C10-C13 with 60% chlorine) were fed to 93 laying hens from 24 to 32 weeks of age in increasing concentrations of up to 100 mg/kg feed. No significant influence on health, relative organ weights or performance (laying intensity, egg weight, feed consumption) was noted. The chlorinated paraffin content of the tissues was linearly related to the concentration of short chain paraffins of the feed. The highest concentrations were found in abdominal fat, egg yolk and fatty tissues. Breast muscle, egg albumen and bile fluid contained minimal or no residues. Less than 1% of the chlorinated paraffins ingested were incorporated into the body (without head, feet, gut and feathers), whereas about 1.5% were eliminated with the egg yolk and 30% were excreted with urine and faeces. A six-week kinetic depuration study revealed a biphasic elimination with half-lifes of 4-40 min (liver, kidneys, legs, fat, blood) for the initial rapid phase, and 15-30 days (blood, fat, liver, yolk, kidneys, legs) for the terminal slow phase.

  5. Study of radioactive nuclides of very short half-life produced by fast neutrons; Etude de corps radioactifs a vie tres breve produits par neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Monnand, E [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-07-01

    Several radionuclides, already known, with half-lives ranging from 5 10{sup -5} to 1 second were observed by pulsed irradiations of C - Mg - Al - Y - In - Tl - Pb - Bi with 14.3 MeV neutrons. These radionuclides are: {sup 12}B (20 {+-} 0.4 ms) - {sup 24m}Na (20 {+-} 0.6 ms) - {sup 88m1}Y (0.332 {+-} 0.012 ms) - {sup 88m2}Y (14.6 {+-} 0.4 ms) - {sup 114m}In (43.5 {+-} 2 ms) - {sup 202m}Tl (0.570 {+-} 0.010 ms) - {sup 204m}Tl (0.063 {+-} 0.002 ms) - {sup 205m}Pb (5.5 {+-}0.3 ms) - {sup 206m}Pb (0.126 {+-} 0.006 ms) - {sup 207m}Pb (830 {+-} 30 ms) - {sup 208m}Bi (2.56 {+-} 0.1 ms). Their half-life, the {beta} and {gamma} rays energies and the production cross sections were measured. (author) [French] Plusieurs radionucleides deja connus, de periode comprise entre 5 10{sup -5} et 1 seconde ont ete observes par irradiation pulsee avec des neutrons de 14,3 MeV, des elements suivants: C - Mg - Al - Y - In - Tl - Pb - Bi. Ces radionucleides sont: {sup 12}B (20 {+-} 0.4 ms) - {sup 24m}Na (20 {+-} 0.6 ms) - {sup 88m1}Y (0.332 {+-} 0.012 ms) - {sup 88m2}Y (14.6 {+-} 0.4 ms) - {sup 114m}In (43.5 {+-} 2 ms) - {sup 202m}Tl (0.570 {+-} 0.010 ms) - {sup 204m}Tl (0.063 {+-} 0.002 ms) - {sup 205m}Pb (5.5 {+-}0.3 ms) - {sup 206m}Pb (0.126 {+-} 0.006 ms) - {sup 207m}Pb (830 {+-} 30 ms) - {sup 208m}Bi (2.56 {+-} 0.1 ms). Leur periode, l'energie des rayonnements {beta} et {gamma} emis, et la section efficace de production ont ete mesurees. (auteur)

  6. Characterization of the liquid argon veto of the GERDA experiment and its application for the measurement of the "7"6Ge half-life

    International Nuclear Information System (INIS)

    Wegmann, Anne Christin

    2017-01-01

    The search for neutrinoless double-beta decay (0νββ) is one of the most active fields in modern particle physics as the observation of this process would prove lepton number violation and imply new physics beyond the Standard Model of particle physics. The GERDA experiment searches for this decay by operating bare Germanium detectors, enriched in the ββ isotope "7"6Ge, in liquid argon. For the first time, a ββ-experiment combines the excellent properties of semiconductor Germanium detectors with an active background suppression technique based on the simultaneous detection of liquid argon scintillation light by photomultiplier tubes and silicon photomultipliers coupled to scintillating fibers (LAr veto). The LAr veto has been successfully operated during the first six months of Phase II of the experiment and yielded - in combination with a Germanium detector pulse shape discrimination technique - a background index of (0.7"+"1"."1_-_0_._5).10"-"3 ((cts)/(kg.keV.yr)). With an ultimate exposure of 100 kg.yr this will allow for a 0νββ-decay half-life sensitivity of the Gerda Phase II experiment of 10"2"6 yr. Double-beta decay under the emission of two neutrinos (2νββ) is a second-order process but which is allowed by the Standard Model. The excellent background reduction of the LAr veto results in an unprecedented signal-to-background ratio of 30:1 in the energy region dominated by 2νββ-decay of "7"6Ge. The remaining background after LAr veto is estimated using the suppression factor from calibration source measurements and results in a measurement of T"2"ν_1_/_2=(1.98±0.02(stat)±0.05(syst)).10"2"1 yr and T_1_/_2"2"ν=(1.92 ±0.02(stat)±0.11(syst)).10"2"1 yr based on two different detector designs and give uncertainties on the detector parameters but both with improved systematic uncertainties in comparison to earlier measurements.

  7. Characterization of the liquid argon veto of the GERDA experiment and its application for the measurement of the {sup 76}Ge half-life

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne Christin

    2017-01-18

    The search for neutrinoless double-beta decay (0νββ) is one of the most active fields in modern particle physics as the observation of this process would prove lepton number violation and imply new physics beyond the Standard Model of particle physics. The GERDA experiment searches for this decay by operating bare Germanium detectors, enriched in the ββ isotope {sup 76}Ge, in liquid argon. For the first time, a ββ-experiment combines the excellent properties of semiconductor Germanium detectors with an active background suppression technique based on the simultaneous detection of liquid argon scintillation light by photomultiplier tubes and silicon photomultipliers coupled to scintillating fibers (LAr veto). The LAr veto has been successfully operated during the first six months of Phase II of the experiment and yielded - in combination with a Germanium detector pulse shape discrimination technique - a background index of (0.7{sup +1.1}{sub -0.5}).10{sup -3} ((cts)/(kg.keV.yr)). With an ultimate exposure of 100 kg.yr this will allow for a 0νββ-decay half-life sensitivity of the Gerda Phase II experiment of 10{sup 26} yr. Double-beta decay under the emission of two neutrinos (2νββ) is a second-order process but which is allowed by the Standard Model. The excellent background reduction of the LAr veto results in an unprecedented signal-to-background ratio of 30:1 in the energy region dominated by 2νββ-decay of {sup 76}Ge. The remaining background after LAr veto is estimated using the suppression factor from calibration source measurements and results in a measurement of T{sup 2ν}{sub 1/2}=(1.98±0.02(stat)±0.05(syst)).10{sup 21} yr and T{sub 1/2}{sup 2ν}=(1.92 ±0.02(stat)±0.11(syst)).10{sup 21} yr based on two different detector designs and give uncertainties on the detector parameters but both with improved systematic uncertainties in comparison to earlier measurements.

  8. Pulse shape analysis for the GERDA experiment to set a new limit on the half-life of 0νββ decay of {sup 76}Ge

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Victoria Elisabeth

    2017-01-25

    The GERDA experiment searches for neutrinoless double beta (0νββ) decay of {sup 76}Ge using high purity germanium (HPGe) detectors operated in liquid argon (LAr). The aim is to explore half-lives of the order of 10{sup 26} yr. Therefore, GERDA relies on improved active background reduction techniques such as pulse shape discrimination (PSD) in which the time structure of the germanium signals is analyzed to discriminate signal- from background-like events. Two types of HPGe detectors are operated: semi-coaxial detectors previously used in the Heidelberg-Moscow and IGEX experiments and new Broad Energy Germanium (BEGe) detectors which feature an improved energy resolution and enhanced PSD. In Phase I of the experiment, five enriched BEGe detectors were used for the first time in the search for 0νββ decay. A PSD based on a single parameter, the ratio of the maximum current amplitude over the energy A/E is applied. 83% of the background events in a 232 keV region around Q{sub ββ} are rejected with a high signal efficiency of (92.1 ± 1.9) %. The achieved background index (BI) is (5.4{sup +4.1}{sub -3.4}) . 10{sup -3} (counts)/(keV.kg.yr). This is an improvement by a factor of 10 compared to previous germanium based 0νββ experiments. Phase II of the experiment includes a major upgrade: for further background rejection, the LAr cryostat is instrumented to detect argon scintillation light. Additional 25 BEGe detectors are installed. After PSD and LAr veto a BI of (0.7{sup +1.3}{sub -0.5}) . 10{sup -3} (counts)/(keV.kg.yr) is achieved. This is the best BI achieved in 0νββ experiments so far. A frequentist statistical analysis is performed on the combined data collected in GERDA Phase I and the first Phase II release. A new limit on the half-life of 0νββ decay of {sup 76}Ge is set to T{sup 0ν}{sub 1/2}>5.3.10{sup 25} yr at 90% C.L., with a median sensitivity of T{sup 0ν}{sub 1/2}>4.0.10{sup 25} yr at 90% C.L.

  9. Positive serum specific IgE has a short half-life in patients with penicillin allergy and reversal does not always indicate tolerance.

    Science.gov (United States)

    Hjortlund, Janni; Mortz, Charlotte Gotthard; Stage, Tore Bjerregaard; Skov, Per Stahl; Dahl, Ronald; Bindslev-Jensen, Carsten

    2014-01-01

    The positive and negative predictive values of specific IgE to penicillins are not well established for penicillin hypersensitivity. One reason may be that serum IgE levels to penicillin diminish over time. The objective in this study was to investigate variations in serum half-life (T½) for specific IgE to penicillins (s-IgE) and to evaluate the outcome of penicillin challenges in patients with previous but not present specific IgE to penicillins. Two subgroups were investigated. All included patients had a history of penicillin allergy with reported symptoms such as urticaria/angioedema or unclassified cutaneous rash. T½ of specific IgE to penicillins was calculated based on sera from 29 patients with repeated measurements of s-IgE. Twenty-two patients with a previous positive s-IgE was followed and challenged with penicillin when IgE had become negative. The T½ for s-IgE varied between the 26 patients with decreasing s-IgE from 1.6 months to 76.4 months and 52% had a T½ of less than a year. The three patients with stable and increasing IgE-values showed T½ approaching infinity A total of 29 challenges with β-lactams were performed. Four different patterns were seen when evaluating the clinical reaction to challenge (positive/negative) and post-challenge boost of s-IgE (yes/no). Eight (36.4%) had negative challenge and negative post-challenge s-IgE, eight (36.4%) negative challenge, but positive post-challenge s-IgE levels. 3 (13.6%) had positive challenge and positive post-challenge s-IgE whereas 3 (13.6%) were challenge positive, but had negative post-challenge s-IgE. Specific IgE to penicillins declines over time stressing the importance of a close time relation between diagnostic work-up and clinical reaction. Reversal of previously positive s-IgE may still be associated with positive penicillin challenges and/or re-boostering of s-IgE to positivity.

  10. 25 CFR 11.1114 - Termination.

    Science.gov (United States)

    2010-04-01

    ... Minor-in-Need-of-Care Procedure § 11.1114 Termination. (a) Parental rights to a child may be terminated... rights if, following efforts to prevent or eliminate the need to remove the minor, it finds such efforts... alternatives: (1) If parental rights to a child are terminated, the children's court shall place the minor in a...

  11. Real-time RT-PCR analysis of mRNA decay: half-life of Beta-actin mRNA in human leukemia CCRF-CEM and Nalm-6 cell lines

    Directory of Open Access Journals (Sweden)

    Barredo Julio C

    2002-03-01

    Full Text Available Abstract Background We describe an alternative method to determine mRNA half-life (t1/2 based on the Real-Time RT-PCR procedure. This approach was evaluated by using the β-actin gene as a reference molecule for measuring of mRNA stability. Results Human leukemia Nalm-6 and CCRF-CEM cells were treated with various concentrations of Actinomycin D to block transcription and aliquots were removed periodically. Total RNA was isolated and quantified using the RiboGreen® fluorescent dye with the VersaFluor Fluorometer System. One μg of total RNA was reverse transcribed and used as template for the amplification of a region of the β-actin gene (231 bp. To generate the standard curve, serial ten-fold dilutions of the pBactin-231 vector containing the cDNA amplified fragment were employed, β-actin mRNAs were quantified by Real-Time RT-PCR using the SYBR® Green I fluorogenic dye and data analyzed using the iCycle iQ system software. Using this method, the β-actin mRNA exhibited a half-life of 6.6 h and 13.5 h in Nalm-6 and CCRF-CEM cells, respectively. The t1/2 value obtained for Nalm-6 is comparable to those estimated from Northern blot studies, using normal human leukocytes (5.5 h. Conclusions We have developed a rapid, sensitive, and reliable method based on Real-Time RT-PCR for measuring mRNA half-life. Our results confirm that β-actin mRNA half-life can be affected by the cellular growth rate.

  12. The half-life of 25(OH)D after UVB exposure depends on gender and vitamin D receptor polymorphism but mainly on the start level

    DEFF Research Database (Denmark)

    Datta, Pameli; Philipsen, Peter A.; Olsen, Peter

    2017-01-01

    The 25-hydroxy vitamin D (25(OH)D) production caused by UVB exposure is usually underestimated as the concurrent degradation of 25(OH)D is not considered. Therefore, the decrease in 25(OH)D was investigated during a 7-week period in winter when ambient UVB is negligible. Twenty-two healthy Danish....... This suggests a quantitatively larger elimination of 25(OH)D at high 25(OH)D start levels. A linear model (logarithm of 25(OH)D) including personal start levels as intercepts and a slope influenced by gender and the vitamin D receptor gene polymorphism rs2228570 explained 87.8% of the observed variation...

  13. Methodical Challenges and a Possible Resolution in the Assessment of Receptor Reserve for Adenosine, an Agonist with Short Half-Life

    Directory of Open Access Journals (Sweden)

    Judit Zsuga

    2017-05-01

    Full Text Available The term receptor reserve, first introduced and used in the traditional receptor theory, is an integrative measure of response-inducing ability of the interaction between an agonist and a receptor system (consisting of a receptor and its downstream signaling. The underlying phenomenon, i.e., stimulation of a submaximal fraction of receptors can apparently elicit the maximal effect (in certain cases, provides an opportunity to assess the receptor reserve. However, determining receptor reserve is challenging for agonists with short half-lives, such as adenosine. Although adenosine metabolism can be inhibited several ways (in order to prevent the rapid elimination of adenosine administered to construct concentration–effect (E/c curves for the determination, the consequent accumulation of endogenous adenosine biases the results. To address this problem, we previously proposed a method, by means of which this bias can be mathematically corrected (utilizing a traditional receptor theory-independent approach. In the present investigation, we have offered in silico validation of this method by simulating E/c curves with the use of the operational model of agonism and then by evaluating them using our method. We have found that our method is suitable to reliably assess the receptor reserve for adenosine in our recently published experimental setting, suggesting that it may be capable for a qualitative determination of receptor reserve for rapidly eliminating agonists in general. In addition, we have disclosed a possible interference between FSCPX (8-cyclopentyl-N3-[3-(4-(fluorosulfonylbenzoyloxypropyl]-N1-propylxanthine, an irreversible A1 adenosine receptor antagonist, and NBTI (S-(2-hydroxy-5-nitrobenzyl-6-thioinosine, a nucleoside transport inhibitor, i.e., FSCPX may blunt the effect of NBTI.

  14. Dose-dependent elimination of 8-methoxypsoralen in the mouse

    International Nuclear Information System (INIS)

    Cheney, P.; Pacula, C.M.; Gerber, N.; Mays, D.C.

    1986-01-01

    8-Methoxypsoralen (8-MOP), a photoactive linear furocoumarin, is effective in the treatment of several diseases, including psoriasis, mycosis fungoides and T-cell leukemia. Recently, a specific extraction procedure for 14 C-8-MOP showed that the elimination of 8-MOP in the rat was dose-dependent. Similar pharmacokinetic studies were undertaken in mice. Purity of 14 C-8-MOP, verified by a four-tube countercurrent distribution using hexane (8 ml) and pH 7.4 phosphate buffer (0.1 M 15 ml) as described by Bush, was >98% and distributed with a partition coefficient of 3.86. Male CD-1 mice were each given an i.p. dose of 10 or 50 mg/kg of 14 C-8-MOP (3.4 μCi/mg) sacrificed at timed intervals, homogenized in 150 ml of 0.1 M phosphate buffer (pH 7.4) and a portion (0.8 ml) of the homogenate used to quantify 8-MOP as described above. The elimination half-life measured in the first 45 min was 7.4 min at 10 mg/kg and 95 min at 50 mg/kg. A similar half-life of 9.2 min was measured in mice given an i.v. dose 10 mg/kg of 8-MOP. Explanations of dose-dependent elimination include enzyme saturation, product inhibition or both. Between 58-80% of the administered radioactivity was recovered in the urine within 24 hr. Nine peaks of radioactivity were observed in the urine by HPLC, two of which coeluted with 5,8-dihydroxypsoralen and 6-(7-hydroxy-8-methoxycoumaryl)-acetic acid

  15. Distribution and elimination of Norfloxacin in Fenneropenaeus chinensis larvae

    Science.gov (United States)

    Sun, Ming; Li, Jian; Zhao, Fazhen; Li, Jitao; Chang, Zhiqiang

    2013-09-01

    This study examined the distribution and elimination of Norfloxacin (NFLX) in Fenneropenaeus chinensis ovary and egg and newly hatched larvae. Mature parental shrimp were exposed to 4 or 10 mg L-1 NFLX for 2 or 5 d. Ovary and eggs of the shrimp were sampled after spawning in order to detect NFLX residue using high-performance liquid chromatography (HPLC). Results showed that NFLX residue accumulated in F. chinensis eggs after the parental exposure, with the highest residue detected in ovary. To examine the fate of NFLX residue in larvae, we further determined the concentration of NFLX residue in F. chinensis eggs and larvae at 4 different developmental stages after 24-h exposure. From the newly metamorphosed larvae (0 h post-metamorphosis, h.p.m), samples were taken at different time intervals to 72 h.p.m. HPLC assay showed that the concentrations of NFLX residue in zoea exposed to 4 and 10 mg L-1 NFLX were the highest at 1.5 h, i.e., 0.332 and 0.454 μg g-1, respectively. At the two NFLX exposure levels, the elimination time of half NFLX (half life) in nauplius was 45.36 and 49.85 h, respectively, followed by that in zoea (31.68 and 33.13 h), mysis larvae (42.24 and 47.28 h) and postlarvae (24.48 and 30.96 h). Both NFLX exposure levels had a germicidal effect. The distribution and elimination of NFLX residue in F. chinensis tissue, eggs and larvae correlated well with the drug exposure level. The disappearance of NFLX residue coincided with the larval growth, and the half-life of NFLX decreased with the larval development.

  16. Whole-genome analysis of mRNA decay in Plasmodium falciparum reveals a global lengthening of mRNA half-life during the intra-erythrocytic development cycle.

    Science.gov (United States)

    Shock, Jennifer L; Fischer, Kael F; DeRisi, Joseph L

    2007-01-01

    The rate of mRNA decay is an essential element of post-transcriptional regulation in all organisms. Previously, studies in several organisms found that the specific half-life of each mRNA is precisely related to its physiologic role, and plays an important role in determining levels of gene expression. We used a genome-wide approach to characterize mRNA decay in Plasmodium falciparum. We found that, globally, rates of mRNA decay increase dramatically during the asexual intra-erythrocytic developmental cycle. During the ring stage of the cycle, the average mRNA half-life was 9.5 min, but this was extended to an average of 65 min during the late schizont stage of development. Thus, a major determinant of mRNA decay rate appears to be linked to the stage of intra-erythrocytic development. Furthermore, we found specific variations in decay patterns superimposed upon the dominant trend of progressive half-life lengthening. These variations in decay pattern were frequently enriched for genes with specific cellular functions or processes. Elucidation of Plasmodium mRNA decay rates provides a key element for deciphering mechanisms of genetic control in this parasite, by complementing and extending previous mRNA abundance studies. Our results indicate that progressive stage-dependent decreases in mRNA decay rate function are a major determinant of mRNA accumulation during the schizont stage of intra-erythrocytic development. This type of genome-wide change in mRNA decay rate has not been observed in any other organism to date, and indicates that post-transcriptional regulation may be the dominant mechanism of gene regulation in P. falciparum.

  17. The biochemical mechanisms responsible for differences in the half-life of monomeric 239Pu in rat and Syrian hamster liver

    International Nuclear Information System (INIS)

    Seidel, A.; Winter, R.; Jentzsch, C.; Gruner, R.; Heumann, H.G.; Hanke, S.

    1979-01-01

    The subcellular distribution of 239 Pu citrate in rat and Syrian hamster liver was studied with the help of the non-ionic detergent Triton WR1339, used as method for separating lysosomes from other cell organelles. Triton WR1339 was injected six days after 239 Pu and the animals were sacrificed after Day 10. Liver homogenates were subjected to differential and isopycnic centrifugation in sucrose gradients. In both animal species 90% of 239 Pu of the post-nuclear supernatant was found in the fraction containing mitochondria, lysosomes, endoplasmatic reticulum and ferritin. Triton WR1339 injection caused a concomitant shift of the lysosomal marker acid phosphatase and of 239 Pu from high densities to rho approximately 1.10 in both animal species. According to our results, binding of 239 Pu to mitochondria and peroxisomes can be excluded, and association to endoplasmatic reticulum and plasma membranes is not very probable. We must consider the possibility that a part of the radioactivity occurring at rho approximately 1.10 can also be bound to ferritin. According to these findings, lysosomes could be one of the main storage sites for 239 Pu in both species. From studies on the pharmacokinetics of 3 H-labelled Triton WR1339 and on the behaviour of Triton-filled rat liver lysosomes, which are also presented in the paper, it is tentatively concluded that the rapid excretion of 239 Pu from rat liver is due to the normally rapid elimination of lysosomal material from hepatocytes into the bile in this species. In Syrian hamsters the fate of lysosomal material in liver may be different or redistribution of 239 Pu occurs at a later time. (author)

  18. Sub-nanosecond Half-life Measurement of the Yrast I{sup π}=5{sup −} State in the N=78 Nucleus {sup 136}{sub 58}Ce using Fast-timing Coincident Gamma-ray Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Alharbi, T. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Physics, Faculty of Science in Zulfi, Almajmaah University, P.O. Box 1712, 11932 (Saudi Arabia); Regan, P.H., E-mail: p.regan@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); National Physical Laboratory, Teddington, Middlesex, TW11 0LW (United Kingdom); Mărginean, N. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Podolyák, Zs.; Bajoga, A.; Britton, R. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Bucurescu, D.; Deleanu, D.; Filipescu, D.; Ghită, D.; Glodariu, T.; Mihai, C. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Mulholland, K. [School of Engineering, University of the West of Scotland, High Street, Paisley PA1 2BE (United Kingdom); Mărginean, R.; Negret, A.; Nita, C.R. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); Patel, Z. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Roberts, O.J. [School of Computing Engineering and Mathematics, University of Brighton, Brighton, BN2 4GJ (United Kingdom); Stroe, L.; Sava, T. [Horia Hulubei – National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest (Romania); and others

    2014-06-15

    We report on the measurement of the half-life of the yrast I{sup π}=5{sup −} state in the transitional nucleus {sup 136}Ce using a combined HPGe-LaBr3(Ce) scintillator gamma-ray detection array. The measured value for the E1 decay is approximately half a nanosecond, which corresponds to an E1 decay strength of approximately 2×10{sup −6} Wu. This value is in line with single-particle type E1 decays in this mass region and suggests no sign of additional K-hindrance associated with axially symmetric quadrupole deformations observed for lighter cerium isotopes.

  19. USCIS Backlog Elimination

    Data.gov (United States)

    Department of Homeland Security — USCIS is streamlining the way immigration benefits are delivered. By working smarter and eliminating redundancies, USCIS is bringing a business model to government....

  20. Operating characteristics of a partial-block randomized crossover bioequivalence study for dutasteride, a drug with a long half-life: investigation through simulation and comparison with final results.

    Science.gov (United States)

    Cai, Gengqian; Thiessen, Jake J; Baidoo, Charlotte A; Fossler, Michael J

    2010-10-01

    Studies to establish bioequivalence (BE) of a drug are important elements in support of drug applications. A typical BE study is conducted as a single dose, randomized, 2-period crossover design. For drugs with long half lives (≥ 48 hours) and evaluation of multiple BE objectives in 1 trial, this design may not be adequate. A parallel design may then be a more appropriate choice. However, parallel designs require increased sample size, which can become substantial. One option that is a compromise between the complete randomized block design and the parallel design is a partial-block crossover design. This approach came about during the development of a combination of dutasteride and tamsulosin. Previous experience with performing single-dose dutasteride studies suggested that 28 days of washout is needed between treatments because of its half-life of 7-9 days. Simulations were performed to assess the operating characteristics of this design using a previously developed PK model. Four scenarios were developed, and each scenario was simulated 500 times. The results showed that this design demonstrated acceptable consumer and producer risk. Partial-block crossover designs should be considered for studies when the half-life of the drug is long and there are more than 2 periods.

  1. Elimination of {sup 137}Cs from Japanese Catfish Acutely Contaminated by Labelled Food

    Energy Technology Data Exchange (ETDEWEB)

    Malek, M. A. [Atomic Energy Center, Dhaka (Bangladesh); Nakahara, M. [Laboratory for Radioecology, National Institute of Radiological Sciences, Isozaki, Hitachinaka City, Ibaraki-ken (Japan)

    2013-07-15

    The effective half-life of {sup 137}Cs in acutely contaminated Japanese catfish was determined. The fish were fed with fish meal incorporated with {sup 137}CsCl and then released into aquaria. To assess the {sup 137}Cs activity retained in the fish body, the whole body radioactivity of each fish was measured at regular intervals for up to 157 days. The data were plotted with relative counts on the y-axis and corresponding elapsed time on the x-axis. Relative count plotted against elapsed time was found to consist of three components, namely the first fast, second fast and the slow component. The true elimination curves of the first components were calculated by the peeling off method. The effective half-life of the fast components was determined from the slope of the true curves. The effective half-life of {sup 137}Cs for the first fast, second fast and the slow component in Japanese catfish was found to be 1.27, 5.76 and 251 days, respectively. (author)

  2. Influence of antithyroid medication on effective half-life and uptake of {sup 131}I following radioiodine therapy; Einfluss thyreostatischer Medikation beim Morbus Basedow auf die Kinetik von 131-Iod waehrend einer Radiotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Moka, D.; Voth, E.; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1997-12-01

    Aim of this study was to assess the influence of antithyroid drugs (ADT) on the kinetics of {sup 131}I. Therefore, 56 patients with Graves` disease and with shortened effective half-life of {sup 131}I were examined under stationary conditionary conditions. In 38 patients ATD was stopped three days after radioiodine therapy (RIT). The progress of the first RIT and of a second RIT, which still was necessary in 12 patients, was compared to 18 patients receiving ATD continuously. Values of effective half-life for {sup 131}I rose significantly from 3.4 to 5.7 days 2-3 days after stopping ATD. There was an increase of the {sup 131}I-uptake of a second RIT after stopping ATD from 29.0 to 38.4%. In contrast, {sup 131}I-uptake of a second RIT decreased significantly in patients receiving ATD continuously. Effective half-life and uptake of {sup 131}I were affected significantly by ATD. Interrupting ATD after RIT is useful to improve an apparantly insufficient RIT in thyrotoxic patients receiving ATD. (orig.) [Deutsch] Ziel dieser Studie war es, beim M. Basedow die Kinetik von {sup 131}I unter dem Einfluss thyreostatischer Medikation (tM) zu untersuchen. Dazu wurden die 56 Patienten mit immunogener Hyperthyreose M. Basedow (MB) und mit einem erhoehten `turn over` von {sup 131}I unter tM untersucht. Bei 38 Patienten wurde die tM am 3. Tag nach RITh abgesetzt. Der Verlauf der 1. RITh bzw. einer Nachtherapie wurde mit 18 Patienten unter fortlaufender tM verglichen. 2-3 Tage nach Absetzen der tM stieg die effektive Halbwertzeit (HWZ{sub eff.}) von {sup 131}I signifikant von 3,4 auf 5,7 Tage und der {sup 131}I-Uptake bei der Nachtherapie von 29,0 auf 38,4% an, waehrend er unter fortlaufender tM signifikant abfiel. Beide Effekte zeigen, dass tM die {sup 131}I-Kinetik der Schilddruese sehr schnell beeinflussen kann. Gezieltes Absetzen der tM eignet sich deshalb, um bei ausgewaehlten Patienten eine primaer unzureichende RITh noch waehrend des stationaeren Aufenthaltes zu steuern und

  3. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  4. Tissue distribution and elimination of rotenone in rainbow trout

    Science.gov (United States)

    Gingerich, W.H.

    1986-01-01

    The fate of a single i.v. dose (120 μg/kg) of the piscicide [14C]rotenone was evaluated in rainbow trout for periods up to 72 h after dosing. Rotenone was rapidly cleared from the plasma; less than 2% of the dose remained in the plasma compartment after 20 min. The highest concentrations of rotenone residues (% dose/g tissue) were in the hepatobiliary system, bile, intestine, and in heart, lateral line swimming muscle, and posterior kidney; tissues that are highly dependent on oxidative metabolism. Although rotenone activity was present in all cell fractions examined, greater than 40% was associated with the mitochondrial fraction of liver, kidney, and muscle. More than 85% of the activity extracted from these tissues, except the liver, was parent rotenone. Elimination from whole body and major tissue depots conformed to simple first-order kinetics; the estimated half-life from whole body was 68.5 h. Branchial elimination accounted for 5% of the injected dose over a 4-h period, and urinary elimination was less than 2% over a 48-h period. Rotenone was eliminated essentially unchanged across the gills; however, parent rotenone was not found in either urine or bile. More than 80% of the activity in both urine and bile eluted from HPLC chromatographs as a highly polar fraction that was not hydrolyzed by incubation with either β-glucuronidase or sulfatase. The results imply that hepatobiliary excretion is the major route of elimination for rotenone residues in the trout and that metabolism to a more polar form is a prerequisite for elimination in both the bile and the urine

  5. Elimination of cotinine from body fluids: implications for noninvasive measurement of tobacco smoke exposure.

    Science.gov (United States)

    Jarvis, M J; Russell, M A; Benowitz, N L; Feyerabend, C

    1988-01-01

    Cotinine elimination from plasma, saliva, and urine was studied over 11 days in five subjects (three nonsmokers and two occasional smokers). Half-lives for cotinine averaged 16-19 hours in the different body fluids (range 10 to 27 hours between subjects). There was no tendency for the half-life in saliva to be longer than in plasma or urine. We conclude that choice of body fluid for cotinine assay in smoking studies should depend on practical rather than pharmacokinetic considerations. PMID:3369603

  6. Elimination of Linear Alkylbenzene Sulfonate (LAS) and soap during composting of anaerobic sludge

    Energy Technology Data Exchange (ETDEWEB)

    Prats, D.; Rodriguez, M.; Muela, M.A.; Llamas, J.M.; Moreno, A.; Ferrer, J. De; Berna, J.L.

    2003-07-01

    The composting plant uses a variety of agricultural residue and sludge from nearby wastewater treatment plants. The results obtained indicate a very high removal of LAS (>97%) in a very short period of time while the removal of soap was substantially lower (32%) as well as the elimination of TOC (total organic matter). The average half life of LAS in the process was between 6 and 9 days which is very short compared to the average residence time of the feed in the composting process (40 days). (author)

  7. Elimination of Chloramphenicol by Tiger Shrimp (Penaeus monodon and White Shrimp (Litopenaeus vannamei

    Directory of Open Access Journals (Sweden)

    Heny Suseno

    2016-07-01

    Full Text Available Chloramphenicol (CAP has been illegally used in many shrimp farms in South East Asia, including Indonesia. We performed an experiment of elimination simulation of CAP in tiger shrimp (Penaeus monodon and white shrimp (Litopenaeus vannamei. After 5 days of depuration process, the concentration of CAP in P. monodon decreased to 94.85% (muscle, 97.98% (cephalothoraxes, and 90.30% (exoskeleton. The elimination half-life of CAP in P monodon was 0.596 day in the muscle, 0.716 day in cephalothorax, and 0.437 day in exoskeleton. On the other hand, concentrations of CAP in L. vannamei decreased to 97.74% (muscle, 90.30% (cephalothoraxes, and 97.63% (exoskeleton. The elimination half-life of CAP in L. vannamei was 0.6624 day (muscle, 0.859 day (cephalothorax, and 0.796 day (exoskeleton. CAP was retained better by P. monodon compared to L. vannamei.

  8. Elimination of ascorbic acid after high-dose infusion in prostate cancer patients

    DEFF Research Database (Denmark)

    Nielsen, Torben Kjær; Højgaard, Martin; Andersen, Jon Thor Trærup

    2015-01-01

    IV AA. The purpose of the present study was to assess the basic kinetic variables in human beings over a relevant AA dosing interval for proper design of future clinical trials. Ten patients with metastatic prostate cancer were treated for four weeks with fixed AA doses of 5, 30 and 60 g. AA...... was measured consecutively in plasma and indicated first-order elimination kinetics throughout the dosing range with supra-physiological concentrations. The target dose of 60g AA IV produced a peak plasma AA concentration of 20.3 mM. Elimination half-life was 1.87 hr (mean, SD ± 0.40), volume of distribution 0.......19 L/kg (SD ±0.05) and clearance rate 6.02 L/hr (100mL/min). No differences in pharmacokinetic parameters were observed between weeks/doses. A relatively fast first-order elimination with half-life of about 2 hr makes it impossible to maintain AA concentrations in the potential cytotoxic range after...

  9. Availability of zeolite as an eliminant for the incorporated radionuclides, (3)

    International Nuclear Information System (INIS)

    Sato, Itaru; Matsusaka, Naonori; Kobayashi, Haruo; Nishimura, Yoshikazu.

    1994-01-01

    Zeolite is an inorganic ion-exchanger that is widely used in chemistry, livestock and industry. The authors have tried to apply it to an eliminant for the incorporated radionuclides. In this study, several experiments in vitro and in vivo were carried out to evaluate the effectiveness of zeolite (A-3) in eliminating the incorporated 137 Cs from the body. Zeolite could adsorb 2.2 mmol of cesium ions per one gram of zeolite in cesium chloride solution. This value was only 44% of its ion-exchange capacity but it completely adsorbed 137 Cs within that limit. Coexistence of magnesium, calcium, manganese, cobalt and zinc ions hardly interfered with the adsorption of 137 Cs, but sodium, potassium and copper ions hindered the adsorption in proportion to their concentration. Therefore, sodium and potassium ions may be principal factors inhibiting the adsorption of 137 Cs in the intestinal tract. Biological half-life of 137 Cs was about 5.5 days in control mice. This half-life was significantly reduced to 5.2, 4.5 and 3.9 days by feeding the diet with 1%, 3% and 10% of zeolite, respectively. These results suggest the effectiveness of zeolite in eliminating the 137 Cs from contaminated persons. (author)

  10. Half-life Measurements of {sup 6}He, {sup 16}N, {sup 19}O, {sup 20}F, {sup 28}Al, {sup 77m}Se and {sup 110}Ag

    Energy Technology Data Exchange (ETDEWEB)

    Konijn, J; Malmskog, S

    1962-06-15

    The half-life of different isotopes, activated by neutrons in the reactor R2-0 by means of a pneumatic rabbit, have been measured with a pulse height analyzer working in its multiscale mode of operation. A Nal(Tl)-scintillation spectrometer was used as detector. Least squares analysis calculated by the Mercury computer were performed for each measurement. The following weighted mean values of the half-lives are obtained {sup 6}He: 0.862 {+-} 0.017 sec.; {sup 16}N: 7.31 {+-} 0.04 sec.; {sup 19}O: 29.1 {+-} 0.3 sec.; {sup 20}F: 11.56 {+-} 0.05 sec.; {sup 28}Al: 2.31 {+-} 0.01 min.; {sup 77m}Se: 18.83 - 0.04 sec.; and {sup 110}Ag: 24.42 {+-} 0.14 sec.

  11. Intravenous elimination and percutaneous absorption of topically applied melphalan-14C (NSC-8806) in Yorkshire white pigs. Final report, 17 August-1 December 1977

    International Nuclear Information System (INIS)

    Skierkowski, P.; Murphy, J.C.; Watson, E.S.; Folk, R.M.; Pavkov, K.L.

    1978-01-01

    The distribution and elimination of intravenously administered Melphalan-14C (NSC-8806) was studied in female, weanling Yorkshire white pigs. A three compartment pharmacokinetic model is indicated with a very slow elimination phase (half life = 214 hours). Assay of tissue samples indicate bone and fat may be acting as depots for the drug. After 8 days an average of 70% was eliminated via the urine. Percutaneous studies showed an average of 4.02% of the applied dose was absorbed after 14 days. Significant levels of radioactivity were also detected in skin surrounding the site of application

  12. The elimination rates of intact GIP as well as its primary metabolite, GIP 3-42, are similar in type 2 diabetic patients and healthy subjects

    DEFF Research Database (Denmark)

    Vilsbøll, Tina; Agersø, Henrik; Lauritsen, Torsten

    2006-01-01

    in the two groups and ranged from 8 to 21 l per subject. The primary metabolite, GIP 3-42, generated through the action of dipeptidyl peptidase IV (DPP-IV), was eliminated with a mean half-life of 17.5 and 20.5 min in patients and healthy subjects (NS). CONCLUSION: Elimination of GIP is similar in obese type...... 2 diabetic patients and matched healthy subjects. Differences in elimination of GIP and its primary metabolite, therefore, do not seem to contribute to the defective insulinotropic effect of GIP in type 2 diabetes....

  13. Accumulation and Elimination of 137Cs Radionuclide by gold fish (Cyprinus Carpio)

    International Nuclear Information System (INIS)

    Hiswara, E; Tjahaya, I P; Wahyudi

    1996-01-01

    A study to estimate accumulation and elimination of 137Cs radionuclide by gold fish (Cyprinus Carpio) has been carried out. The experiment used aquarium as a cultivating media. Gold fish was placed into aquarium filled with 70 liter of water and 137Cs concentration of 10 Bq/ml. From the observing time of 40 days it was found that activity concentration in fish became saturated in 30th day. Saturation after the 30th day was confined by additional observation using 137Cs concentration of 5 and 15 Bq/ml. Saturated concentration fish was then transfered to inactive aquarium to determine is elimination rate. Transfer factor, i.e. the ratio of 137Cs concentration in fish to that in water, was found to be (12.99+0.28) ml/g, whereas the elimination rate of 137Cs was found to be 0.046 day, which correspond to a biological half life of 15 days

  14. Terminal Ballistics

    CERN Document Server

    Rosenberg, Zvi

    2012-01-01

    This book covers the important issues of terminal ballistics in a comprehensive way combining experimental data, numerical simulations and analytical modeling. The first chapter reviews the experimental equipment which are used for ballistic tests and the diagnostics for material characterization under impulsive loading conditions. The second chapter covers essential features of the codes which are used for terminal ballistics such as the Euler vs. Lagrange schemes and meshing techniques, as well as the most popular material models. The third chapter, devoted to the penetration mechanics of rigid penetrators, brings the update of modeling in this field. The fourth chapter deals with plate perforation and the fifth chapter deals with the penetration mechanics of shaped charge jets and eroding long rods. The last two chapters discuss several techniques for the disruption and defeating of the main threats in armor design. Throughout the book the authors demonstrate the advantages of numerical simulations in unde...

  15. Terminal structure

    Science.gov (United States)

    Schmidt, Frank [Langenhagen, DE; Allais, Arnaud [Hannover, DE; Mirebeau, Pierre [Villebon sur Yvette, FR; Ganhungu, Francois [Vieux-Reng, FR; Lallouet, Nicolas [Saint Martin Boulogne, FR

    2009-10-20

    A terminal structure (2) for a superconducting cable (1) is described. It consists of a conductor (2a) and an insulator (2b) that surrounds the conductor (2a), wherein the superconducting cable (1) has a core with a superconducting conductor (5) and a layer of insulation that surrounds the conductor (5), and wherein the core is arranged in such a way that it can move longitudinally in a cryostat. The conductor (2a) of the terminal structure (2) is electrically connected with the superconducting conductor (5) or with a normal conductor (6) that is connected with the superconducting conductor (5) by means of a tubular part (7) made of an electrically conductive material, wherein the superconducting conductor (5) or the normal conductor (6) can slide in the part (7) in the direction of the superconductor.

  16. Radioactive wastes eliminating device

    International Nuclear Information System (INIS)

    Mitsutsuka, Norimasa.

    1979-01-01

    Purpose: To eliminate impurities and radioactive wastes by passing liquid sodium in a cold trap and an adsorption device. Constitution: Heated sodium is partially extracted from the core of a nuclear reactor by way of a pump, flown into and cooled in heat exchangers and then introduced into a cold trap for removal of impurities. The liquid sodium eliminated with impurities is introduced into an adsorption separator and purified by the elimination of radioactive wastes. The purified sodium is returned to the nuclear reactor. A heater is provided between the cold trap and the adsorption separator, so that the temperature of the liquid sodium introduced into the adsorption separator is not lower than the minimum temperature in the cold trap to thereby prevent deposition of impurities in the adsorption separator. (Kawakami, Y.)

  17. Termination unit

    Energy Technology Data Exchange (ETDEWEB)

    Traeholt, Chresten; Willen, Dag; Roden, Mark; Tolbert, Jerry C.; Lindsay, David; Fisher, Paul W.; Nielsen, Carsten Thidemann

    2016-05-03

    Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.

  18. Minding Rachlin's Eliminative Materialism

    Science.gov (United States)

    McDowell, J. J.

    2012-01-01

    Rachlin's teleological behaviorism eliminates the first-person ontology of conscious experience by identifying mental states with extended patterns of behavior, and thereby maintains the materialist ontology of science. An alternate view, informed by brain-based and externalist philosophies of mind, is shown also to maintain the materialist…

  19. Eliminating Perinatal HIV Transmission

    Centers for Disease Control (CDC) Podcasts

    In this podcast, CDC’s Dr. Steve Nesheim discusses perinatal HIV transmission, including the importance of preventing HIV among women, preconception care, and timely HIV testing of the mother. Dr. Nesheim also introduces the revised curriculum Eliminating Perinatal HIV Transmission intended for faculty of OB/GYN and pediatric residents and nurse midwifery students.

  20. Intermittent hemodialysis is superior to continuous veno-venous hemodialysis/hemodiafiltration to eliminate methanol and formate during treatment for methanol poisoning

    Science.gov (United States)

    Zakharov, Sergey; Pelclova, Daniela; Navratil, Tomas; Belacek, Jaromir; Kurcova, Ivana; Komzak, Ondrej; Salek, Tomas; Latta, Jiri; Turek, Radovan; Bocek, Robert; Kucera, Cyril; Hubacek, Jaroslav A; Fenclova, Zdenka; Petrik, Vit; Cermak, Martin; Hovda, Knut Erik

    2014-01-01

    During an outbreak of methanol poisonings in the Czech Republic in 2012, we were able to study methanol and formate elimination half-lives during intermittent hemodialysis (IHD) and continuous veno-venous hemodialysis/hemodiafiltration (CVVHD/HDF) and the relative impact of dialysate and blood flow rates on elimination. Data were obtained from 11 IHD and 13 CVVHD/HDF patients. Serum methanol and formate concentrations were measured by gas chromatography and an enzymatic method. The groups were relatively comparable, but the CVVHD/HDF group was significantly more acidotic (mean pH 6.9 vs. 7.1 IHD). The mean elimination half-life of methanol was 3.7 and formate 1.6 h with IHD, versus 8.1 and 3.6 h, respectively, with CVVHD/HDF (both significant). The 54% greater reduction in methanol and 56% reduction in formate elimination half-life during IHD resulted from the higher blood and dialysate flow rates. Increased blood and dialysate flow on the CVVHD/HDF also increased elimination significantly. Thus, IHD is superior to CVVHD/HDF for more rapid methanol and formate elimination, and if CVVHD/HDF is the only treatment available then elimination is greater with greater blood and dialysate flow rates. PMID:24621917

  1. Influence of antithyroid medication on effective half-life and uptake of {sup 131} I following radioiodine therapy; Einflussfon thyreostatischer Medikation auf die effektive Halbwertzeit und den Uptake von {sup 131}Iod waehrend einer Radioiodtherapie

    Energy Technology Data Exchange (ETDEWEB)

    Moka, D. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Voth, E. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    1997-04-01

    Aim: A radioiodine therapy (RIT) in thyrotoxic patients receiving antithyroid drugs (ATD) leads in comparison to nonpretreated patients either to higher therapeutic doses or to higher treatment failure rates. Aim of this study was to optimize the effect of RIT in patients pretreated with ATD. Methods: Therefore, the influence of ATD was assessed in 109 patients with shortened effective half-life of {sup 131}I. RIT was performed under stationary conditions. Radioiodine activity of the thyroid gland was stopped three days after RIT. The patients antithyroid medication was stopped three days after RIT. The progress of the first RIT and of a second radioiodine application, which still was necessary in 29 patients, was compared to 32 patients receiving ATD, continuously. Results: Values of effective half-life for {sup 131}I rose significantly from 3.2{+-}0.2 to 5.7{+-}0.2 days (Graves` disease: 3.4 to 5.7 days; toxic goiters` disease: Multifocal autonomy 3.2 to 6.2 days; unifocal autonomy 2.5 auf 5.0 days) 2-3 days after stopping ATD. There was an increase of the {sup 131}I-uptake of a second RIT decreased significantly in patients receiving ATD, continuously. Conclusion: Effective half-life and uptake of {sup 131}I was affected significantly by ATD. The stop taking of ATD after RIT is useful to improve an apparent insufficient RIT in thyrotoxic patients receiving ATD. (orig.) [Deutsch] Ziel: Eine Radioiodtherapie (RITh) unter laufender thyreostatischer Medikation bei hyperthyreoten Patienten fuehrt im Vergleich zu unbehandelten Patienten entweder zu hoeheren Therapiedosen oder zu einem hoeheren Prozentsatz von Therapieversagern. Ziel dieser Studie war es, die RITh unter thyreostatischer Medikation zu optimieren. Methoden: Der Einfluss der thyreostatischen Medikation wurde bei 109 Patienten mit verkuerzter thyreoidaler Halbwertzeit von {sup 131}I untersucht. Bei 77 Patienten wurde die thyreostatische Medikation am 3. Tag nach RITh abgesetzt. Der Verlauf der RITh bzw

  2. Eliminating Perinatal HIV Transmission

    Centers for Disease Control (CDC) Podcasts

    2012-11-26

    In this podcast, CDC’s Dr. Steve Nesheim discusses perinatal HIV transmission, including the importance of preventing HIV among women, preconception care, and timely HIV testing of the mother. Dr. Nesheim also introduces the revised curriculum Eliminating Perinatal HIV Transmission intended for faculty of OB/GYN and pediatric residents and nurse midwifery students.  Created: 11/26/2012 by Division of HIV/AIDS Prevention.   Date Released: 11/26/2012.

  3. Goiania radiation accident: 30 years - a half-life for a whole life..; Acidente radiológico em Goiânia: 30 - anos - uma meia-vida para uma vida inteira...

    Energy Technology Data Exchange (ETDEWEB)

    Reis, R.G.; Lucena, E.A.; Arantes, R.R.; Silva, A.A.; Reis, A.A., E-mail: rocio@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Serviço de Ensino

    2017-07-01

    The radiological accident in Goiânia, Brazil, considered the largest urban radiological accident in the world, generated several publications in the technical area that are widely disseminated in the scientific literature, given the importance of the lessons learned. However, in a simple conversation with people who worked on that accident, it is noted that many reports have not been recorded. In this year in which 30 years of the event is completed, it will be of great value to record personal testimonies that are not in technical or scientific books. And what can we tell after a half-life that lasted for a lifetime? The lived stories, the situations, the improvisations, the way to solve, the overcoming, the human side, the emotions, happy or sad, short or long, funny or not. The objective of this work is to preserve, maintain and divulge reports and situations experienced by people who worked on the radiological accident with Cs-137 in Goiânia. Audio or video recordings about experiences lived in Goiânia by people who worked in that emergency situation were carried out. The reports are free and the form of registration is always at the discretion of the narrator. Storing records allows to preserve, maintain, and disclose the accident to other generations.

  4. An overview of the ecological half-life of the 137Cs radioisotope and a determination of radioactivity levels in sediment samples after Chernobyl in the Eastern Black Sea, Turkey

    Science.gov (United States)

    Baltas, Hasan; Sirin, Murat; Dalgic, Goktug; Cevik, Ugur

    2018-01-01

    A study which determined the activity concentration of 137Cs in sediments contaminated by effluents from the Chernobyl accident which had collected along the coast of the Eastern Black Sea region in Turkey was carried out in 1993. Marine sediment samples were collected in 2015 from the same fifteen sampling points, and the activity concentrations of 226Ra, 232Th, 40K and 137Cs were determined for the sediment samples. The activity concentrations ranged from 10.94-25.95, 12.14-33.05, 265.74-459.89 and 2.08-37.45 Bq kg- 1 for 226Ra, 232Th, 40K and 137Cs respectively. The results showed that there was a steep decline in 137Cs within the sediment at most of the sampling sites from the Eastern Black Sea region during the 22-year period, except for two sites at which the measured levels were much higher. This may be the result of the combined effects of radioactive contaminant entry into this area from rivers, environmental changes and nuclear testing between 1993 and 2015. Furthermore, the ecological half-life (EHL) of the 137Cs radionuclide was estimated for the sediment samples, and radiological hazard parameters such as the absorbed dose rate in air (D), the annual effective dose equivalent (AEDE) and the excess lifetime cancer risk (ELCR) were calculated and compared with the international recommended values. It was shown that these sediments do not present any significant health risk for humans in this area.

  5. Safety objectives and basic design for surface centres for long-term storage of solid radioactive waste with short or medium half-life and low or medium specific activity

    International Nuclear Information System (INIS)

    1984-06-01

    RFS or Regles Fondamentales de Surete (Basic Safety Rules) applicable to certain types of nuclear facilities lay down requirements with which compliance, for the type of facilities and within the scope of application covered by the RFS, is considered to be equivalent to compliance with technical French regulatory practice. The object of the RFS is to take advantage of standardization in the field of safety, while allowing for technical progress in that field. They are designed to enable the operating utility and contractors to know the rules pertaining to various subjects which are considered to be acceptable by the Service Central de Surete des Installations Nucleaires, or the SCSIN (Central Department for the Safety of Nuclear Facilities). These RFS should make safety analysis easier and lead to better understanding between experts and individuals concerned with the problems of nuclear safety. The SCSIN reserves the right to modify, when considered necessary, any RFS and specify, if need be, the terms under which a modification is deemed retroactive. The role of this RFS is to define the safety objectives and the basic design philosophy for surface centres for long-term storage of packages of radioactive waste with short or medium half-life and with low or medium specific activity

  6. Investigation of temperature effect on half-life periods of long-lived isomer sup 1 sup 8 sup 0 sup m Hf and sup 8 sup 7 sup m Sr

    CERN Document Server

    Alpatov, V G; Davydov, A V; Isaev, Y N; Kartashov, G R; Korotkov, M M; Samojlov, V M

    2001-01-01

    The experiments on measuring the half-life periods of the sup 1 sup 8 sup 0 sup m Hf and sup 8 sup 7 sup m Sr long-lived isomers at the room temperature and at 77 K with application of the HfO sub 2 , Sr(NO sub 3) sub 2 and SrCO sub 3 massive samples are described. The isomer states of the corresponding nuclei were formed by the samples irradiation through neutrons from the Pu-Be source. According to the Vysotski theory and other authors the surrounding of the gamma-active nuclei by a large number of the same nuclei in the basic state should lead to the T sub 1 sub / sub 2 growth due to distortion of the zero electromagnetic vacuum oscillations near the nuclear energy level value. Decrease in the sample temperature leads to the narrowing of the gamma-lines, especially for the Moessbauer low-energy transitions, which increases the resonance effect on the zero oscillations spectrum. Increase in the T sub 1 sub / sub 2 by 2.99 +- 0.87% was observed by cooling the sup 1 sup 8 sup 0 sup m Hf isomer sample, in the ...

  7. Terminal ballistics

    CERN Document Server

    Rosenberg, Zvi

    2016-01-01

    This book comprehensively discusses essential aspects of terminal ballistics, combining experimental data, numerical simulations and analytical modeling. Employing a unique approach to numerical simulations as a measure of sensitivity for the major physical parameters, the new edition also includes the following features: new figures to better illustrate the problems discussed; improved explanations for the equation of state of a solid and for the cavity expansion process; new data concerning the Kolsky bar test; and a discussion of analytical modeling for the hole diameter in a thin metallic plate impacted by a shaped charge jet. The section on thick concrete targets penetrated by rigid projectiles has now been expanded to include the latest findings, and two new sections have been added: one on a novel approach to the perforation of thin concrete slabs, and one on testing the failure of thin metallic plates using a hydrodynamic ram.

  8. Elimination of salmonella from animal glandular products.

    Science.gov (United States)

    De Fiebre, C W; Burck, K T; Feldman, D

    1969-03-01

    Methods for the elimination of salmonellae from selected powdered pharmaceuticals of animal glandular origin were studied. Terminal heat treatment under carefully controlled conditions was effective for pancreatin-a powder containing proteolytic, amylolytic, and lipolytic enzymes prepared from hog pancreas glands. Use of this method resulted in a significant reduction in the number of salmonella-positive batches and also reduced the testing procedures required to confirm the absence of viable salmonellae among the majority of samples tested. Powders such as stomach substance and thyroid, in which the biological activity is not enzyme in nature, were treated successfully with acidified organic solvents. Other methods were investigated but were not suitable because of a deleterious effect on the biological activity or physical properties of the product or an inability to effect salmonella elimination.

  9. Elimination of Salmonellae from Animal Glandular Products

    Science.gov (United States)

    De Fiebre, Conrad W.; Burck, Kenneth T.; Feldman, David

    1969-01-01

    Methods for the elimination of salmonellae from selected powdered pharmaceuticals of animal glandular origin were studied. Terminal heat treatment under carefully controlled conditions was effective for pancreatin—a powder containing proteolytic, amylolytic, and lipolytic enzymes prepared from hog pancreas glands. Use of this method resulted in a significant reduction in the number of salmonella-positive batches and also reduced the testing procedures required to confirm the absence of viable salmonellae among the majority of samples tested. Powders such as stomach substance and thyroid, in which the biological activity is not enzyme in nature, were treated successfully with acidified organic solvents. Other methods were investigated but were not suitable because of a deleterious effect on the biological activity or physical properties of the product or an inability to effect salmonella elimination. PMID:5780395

  10. Termination unit

    Science.gov (United States)

    Traeholt, Chresten [Frederiksberg, DK; Willen, Dag [Klagshamn, SE; Roden, Mark [Newnan, GA; Tolbert, Jerry C [Carrollton, GA; Lindsay, David [Carrollton, GA; Fisher, Paul W [Heiskell, TN; Nielsen, Carsten Thidemann [Jaegerspris, DK

    2014-01-07

    This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

  11. Risks: diagnosing and eliminating

    Directory of Open Access Journals (Sweden)

    Yuriy A. Tikhomirov

    2016-01-01

    Full Text Available Objective to develop conceptual theoretical and legal provisions and scientific recommendations on the identification analysis and elimination of risk. Methods universal dialectic method of cognition as well as scientific and private research methods based on it. Results the system was researched of risks diagnostics in the legal sphere and mechanism of influencing the quotrisk situationsquot and their consequences damage to the environment and harm to society. The concept of risk in the legal sphere was formulated the author39s classification of risks in the legal sphere is presented. The rules of analysis evaluation and prevention of risks and the model risk management framework are elaborated. Scientific novelty the mechanism for the identification analysis and elimination of risk has been developed and introduced into scientific circulation the author has proposed the classification and types of risks the reasons and the conditions promoting the risk occurrence. Practical significance the provisions and conclusions of the article can be used in the scientific lawmaking and lawenforcement activity as well as in the educational process of higher educational establishments. nbsp

  12. Environmental Metabolic Footprinting (EMF) vs. half-life: a new and integrative proxy for the discrimination between control and pesticides exposed sediments in order to further characterise pesticides' environmental impact.

    Science.gov (United States)

    Salvia, Marie-Virginie; Ben Jrad, Amani; Raviglione, Delphine; Zhou, Yuxiang; Bertrand, Cédric

    2017-06-28

    Pesticides are regularly used for a variety of applications and are disseminated throughout the environment. These substances may have significant negative impacts. To date, the half-life, t 1/2 , was often used to study the fate of pesticides in environmental matrices (water, soil, sediment). However, this value gives limited information. First, it does not evaluate the formation of by-products, resulting in the need for additional experiments to be performed to evaluate biodegradation and biotransformation products. T 1/2 also fails to consider the chemical's impact on biodiversity. Resilience time, a new and integrative proxy, was recently proposed as an alternative to t 1/2 , with the potential to evaluate all the post-application effects of the chemical on the environment. The 'Environmental Metabolic Footprinting' (EMF) approach, giving an idea of the resilience time, was used to evaluate the impact of botanicals on soil. The goal is to optimise the EMF to study the impact of a microbial insecticide, the Bacillus thuringiensis israelensis (Bti), on sediment. The difficulty of this work lies in the commercial solution of Bti that is really complex, and this complexity yields chromatograms that are extremely difficult to interpret; t 1/2 cannot be used. No methodologies currently exist to monitor the impact of these compounds on the environment. We will test the EMF to determine if it is sensitive enough to tolerate such complex mixtures. A pure chemical insecticide, the α-cypermethrin, will be also studied. The article shows that the EMF is able to distinguish meta-metabolome differences between control and exposed (with Bti) sediments.

  13. Direct measurement of the half-life of Rb{sup 87}; Mesure directe de la periode du rubidium-87; Pryamoe izmerenie poluraspada rubidiya-87; Medicion directa del periodo del {sup 87}Rb

    Energy Technology Data Exchange (ETDEWEB)

    McNair, A; Wilson, H W [United Kingdom Atomic Energy Authority, Aldermaston, Berks. (United Kingdom)

    1962-01-15

    The half-life of Rb{sup 87} has been measured directly by determining the specific activity by a counting method. The half-lives previously obtained lie in the range 4 - 6 x 10{sup 10} years, a value of 5 x 10{sup 10} years being taken usually. Direct counting is rather difficult because of the presence of a large number of very-low-energy electrons in the Rb{sup 87} spectrum. However, it is clearly very desirable to obtain a precise value by the counting method and this the authors have tried to do. In these measurements special attention must be paid to the reduction of thickness of source and of source backing. To increase the accuracy of the measurements, the following methods were used. The source thickness was reduced by use of (i) a 4-{pi} proportional counter of large source area (up to 100 cm{sup 2}), (ii) anti-coincidence operation to reduce background, and (iii) enriched Rb{sup 87} which permits a four-fold reduction in source thickness for a given activity. By these methods, sources down to 5 {mu}g/cm{sup 2} have been measured. Also the relationship between half-life and source thickness was examined so that correction could be made for the very small absorption which remained. The effect of source backing thickness is not so great and can be calculated from (i) the difference in count-rates on either side of the thin supports used and (ii) a study of dependence of half-life on source support thickness. These experiments give a value of about 5.25 x 10{sup 10} years for the half-life. (author) [French] On a mesure la periode du Tubidium-87 directement, en determinant l'activite specifique par comptage. Les periodes obtenues anterieurement se situent entre 4 et 6 {center_dot} 10{sup 10} ans; la valeur habituellement adoptee est de 5 {center_dot} 10{sup 10} ans. Le comptage direct est d'un emploi assez difficile par suite de la presence d'un grand nombre d'electrons de tres faible energie dans le spectre du rubidium-87. Il n'en serait pas moins tres utile

  14. Eliminating PCR contamination

    International Nuclear Information System (INIS)

    Fox, J.C.; Ait-Khaled, Mounir; Webster, Alison; Emery, V.C.

    1991-01-01

    The sensitivity of polymerase chain reaction (PCR) can mean that even very low levels of contamination with the target DNA will result in a positive signal. At present this aspect is a major limitation in the use of PCR as a routine diagnostic method. By exposing PCR reagents to UV light, contaminating DNA can be inactivated, thus providing an opportunity to eradicate false positive reactions. UV irradiation was applied to PCR systems used for detection of human cytomegalovirus CMV and human immunodeficiency virus (HIV) and shown to be effective in eradicating both laboratory encountered contamination and plasmid DNA (below 100 pg) added to PCR systems prior to UV exposure. Sensitivity of a PCR system to amplify the long terminal repeat (LTR) sequence of HIV-1 was not affected by the irradiation procedure; however, ultimate sensitivity of a PCR system for the amplification of an early gene pro-motor sequence of the CMV genome was reduced 1000-fold. UV irradiation did not affect the size of the PCR product as determined by strand separating polyacrylamide gel electrophoresis of a 32 P-labelled amplimer. Thus, a simple pre-exposure to UV light would seem a worth-wile step to incorporate into PCR protocols provided that the effects on sensitivity have been determined empirically for each PCR system. (author). 11 refs.; 3 figs

  15. Mutation choice to eliminate buried free cysteines in protein therapeutics.

    Science.gov (United States)

    Xia, Xue; Longo, Liam M; Blaber, Michael

    2015-02-01

    Buried free-cysteine (Cys) residues can contribute to an irreversible unfolding pathway that promotes protein aggregation, increases immunogenic potential, and significantly reduces protein functional half-life. Consequently, mutation of buried free-Cys residues can result in significant improvement in the storage, reconstitution, and pharmacokinetic properties of protein-based therapeutics. Mutational design to eliminate buried free-Cys residues typically follows one of two common heuristics: either substitution by Ser (polar and isosteric), or substitution by Ala or Val (hydrophobic); however, a detailed structural and thermodynamic understanding of Cys mutations is lacking. We report a comprehensive structure and stability study of Ala, Ser, Thr, and Val mutations at each of the three buried free-Cys positions (Cys16, Cys83, and Cys117) in fibroblast growth factor-1. Mutation was almost universally destabilizing, indicating a general optimization for the wild-type Cys, including van der Waals and H-bond interactions. Structural response to Cys mutation characteristically involved changes to maintain, or effectively substitute, local H-bond interactions-by either structural collapse to accommodate the smaller oxygen radius of Ser/Thr, or conversely, expansion to enable inclusion of novel H-bonding solvent. Despite the diverse structural effects, the least destabilizing average substitution at each position was Ala, and not isosteric Ser. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  16. Eliminating Rabies in Estonia

    Science.gov (United States)

    Cliquet, Florence; Robardet, Emmanuelle; Must, Kylli; Laine, Marjana; Peik, Katrin; Picard-Meyer, Evelyne; Guiot, Anne-Laure; Niin, Enel

    2012-01-01

    The compulsory vaccination of pets, the recommended vaccination of farm animals in grazing areas and the extermination of stray animals did not succeed in eliminating rabies in Estonia because the virus was maintained in two main wildlife reservoirs, foxes and raccoon dogs. These two species became a priority target therefore in order to control rabies. Supported by the European Community, successive oral vaccination (OV) campaigns were conducted twice a year using Rabigen® SAG2 baits, beginning in autumn 2005 in North Estonia. They were then extended to the whole territory from spring 2006. Following the vaccination campaigns, the incidence of rabies cases dramatically decreased, with 266 cases in 2005, 114 in 2006, four in 2007 and three in 2008. Since March 2008, no rabies cases have been detected in Estonia other than three cases reported in summer 2009 and one case in January 2011, all in areas close to the South-Eastern border with Russia. The bait uptake was satisfactory, with tetracycline positivity rates ranging from 85% to 93% in foxes and from 82% to 88% in raccoon dogs. Immunisation rates evaluated by ELISA ranged from 34% to 55% in foxes and from 38% to 55% in raccoon dogs. The rabies situation in Estonia was compared to that of the other two Baltic States, Latvia and Lithuania. Despite regular OV campaigns conducted throughout their territory since 2006, and an improvement in the epidemiological situation, rabies has still not been eradicated in these countries. An analysis of the number of baits distributed and the funding allocated by the European Commission showed that the strategy for rabies control is more cost-effective in Estonia than in Latvia and Lithuania. PMID:22393461

  17. Effects of Mitragynine and a Crude Alkaloid Extract Derived from Mitragyna speciosa Korth. on Permethrin Elimination in Rats

    Directory of Open Access Journals (Sweden)

    Kachamas Srichana

    2015-03-01

    Full Text Available Detoxification and elimination of permethrin (PM are mediated by hydrolysis via carboxylesterase (CES. Mitragyna speciosa (kratom contains mitragynine (MG and other bioactive alkaloids. Since PM and MG have the same catalytic site and M. speciosa is usually abused by adding other ingredients such as pyrethroid insecticides, the effects of MG and an alkaloid extract (AE on the elimination of PM were investigated in rats. Rats were subjected to single and multiple pretreatment with MG and AE prior to receiving a single oral dose (460 mg/kg of PM. Plasma concentrations of trans-PM and its metabolite phenoxybenzylalcohol (PBAlc were measured. The elimination rate constant (kel and the elimination half-life (t1/2 el of PM were determined, as well as the metabolic ratio (PMR. A single and multiple oral pretreatment with MG and AE altered the plasma concentration-time courses of both trans-PM and PBAlc during 8–22 h, decreased the PMRs, delayed elimination of PM, but enhanced elimination of PBAlc. Results indicated that PM–MG or AE toxicokinetic interactions might have resulted from the MG and AE interfering with PM hydrolysis. The results obtained in rats suggest that in humans using kratom cocktails containing PM, there might be an increased risk of PM toxicity due to inhibition of PM metabolism and elimination.

  18. Elimination device for metal impurities

    International Nuclear Information System (INIS)

    Yanagisawa, Ko.

    1982-01-01

    Purpose: To enable reuse of adsorbing materials by eliminating Fe 3 O 4 films reduced with adsorbing performance by way of electrolytic polishing and then forming fresh membranes using high temperature steams. Constitution: An elimination device is provided to a coolant clean-up system of a reactor for eliminating impurities such as cobalt. The elimination device comprises adsorbing materials made of stainless steel tips or the likes having Fe 3 O 4 films. The adsorbing materials are regenerated by applying an electric current between grid-like cathode plates and anode plates to leach out the Fe 3 O 4 films, washing out the electrolytic solution by cleaning water and then applying steams at high temperature onto the adsorbing materials to thereby form fresh Fe 3 O 4 films again thereon. The regeneration of the adsorbing materials enables to eliminate Co 60 and the like in the primary coolant efficiently. (Moriyama, K.)

  19. Importance of neonatal FcR in regulating the serum half-life of therapeutic proteins containing the Fc domain of human IgG1: a comparative study of the affinity of monoclonal antibodies and Fc-fusion proteins to human neonatal FcR.

    Science.gov (United States)

    Suzuki, Takuo; Ishii-Watabe, Akiko; Tada, Minoru; Kobayashi, Tetsu; Kanayasu-Toyoda, Toshie; Kawanishi, Toru; Yamaguchi, Teruhide

    2010-02-15

    The neonatal FcR (FcRn) binds to the Fc domain of IgG at acidic pH in the endosome and protects IgG from degradation, thereby contributing to the long serum half-life of IgG. To date, more than 20 mAb products and 5 Fc-fusion protein products have received marketing authorization approval in the United States, the European Union, or Japan. Many of these therapeutic proteins have the Fc domain of human IgG1; however, the serum half-lives differ in each protein. To elucidate the role of FcRn in the pharmacokinetics of Fc domain-containing therapeutic proteins, we evaluated the affinity of the clinically used human, humanized, chimeric, or mouse mAbs and Fc-fusion proteins to recombinant human FcRn by surface plasmon resonance analysis. The affinities of these therapeutic proteins to FcRn were found to be closely correlated with the serum half-lives reported from clinical studies, suggesting the important role of FcRn in regulating their serum half-lives. The relatively short serum half-life of Fc-fusion proteins was thought to arise from the low affinity to FcRn. The existence of some mAbs having high affinity to FcRn and a short serum half-life, however, suggested the involvement of other critical factor(s) in determining the serum half-life of such Abs. We further investigated the reason for the relatively low affinity of Fc-fusion proteins to FcRn and suggested the possibility that the receptor domain of Fc-fusion protein influences the structural environment of the FcRn binding region but not of the FcgammaRI binding region of the Fc domain.

  20. kosh Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kpdt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kewr Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kiso Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kpga Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kbkw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. ktcl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. pgwt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kpsp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kbih Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kdnl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kart Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kilm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kpne Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kabi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. ptpn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kblf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. panc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kpbi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kgdv Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kcmx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kdls Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. koaj Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. krhi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kbpk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. khuf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kbpi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. ktrk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kwmc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. katy Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. tjmz Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kdet Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kcxp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kbur Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. krkd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. pawg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kloz Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kcec Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kdec Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. paor Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kavl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kdrt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kstl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kbfi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. khsv Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. pafa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kekn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. tncm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kith Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kgnv Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. ktoi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kgso Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. nstu Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kmgm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. khib Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. pavd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kfar Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kluk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kwwr Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. klse Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. ksts Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. koth Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kbfl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. ksgf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kpkb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. krog Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kbjc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. ksea Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kbwi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kftw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kpuw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kabq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. ksny Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. khio Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. klaf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kfoe Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. ksmx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kipt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. klch Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. Organizational Relationship Termination Competence

    DEFF Research Database (Denmark)

    Ritter, Thomas; Geersbro, Jens

    2011-01-01

    termination are found to significantly affect a firm's relationship termination competence. The findings suggest that managers should regard termination as a legitimate option in customer relationship management. In order to decrease the number of unwanted customers, managers must accept termination......Most firms are involved in a number of customer relationships that drain the firm's resources. However, many firms are hesitant to address this problem. This paper investigates customer relationship termination at the organizational level. We develop and analyze the organizational dimensions...... of organizational termination in order to improve our understanding of the management of termination. The impact of these termination dimensions on the percentage of unwanted customers is developed and tested using PLS on data gathered from a cross-sectional survey of more than 800 sales representatives. We find...

  20. kink Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. krut Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kbli Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kaoo Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. klit Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. ktup Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. ktop Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. klax Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kprc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. katl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kmcn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kogb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kama Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. ptkk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. kiwa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kavp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kdca Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kbwg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kdfw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kssi Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. pahn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. ksrq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kpvd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kisp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kttd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. pmdy Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kont Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kyng Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kcwa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kflg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. krsw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kmyl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. krbg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kril Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. ksus Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. padq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kbil Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. krfd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kdug Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. ktix Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kcod Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. kslk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kgfl Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. kguc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kmlu Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kbff Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. ksmn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kdro Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kmce Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. ktpa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kmot Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kcre Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. klws Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. kotm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. khqm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. kabr Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. klal Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kelp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kecg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. khbg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kpbf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. konp Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. pkwa Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. ktvf Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. paga Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. khks Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kdsm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. kpsm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kgrb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kgmu Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. papg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kbgm Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. pamc Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. klrd Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. ksan Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. patk Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. kowb Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. klru Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kfxe Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. kjct Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  20. kcrg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  1. paaq Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  2. kaex Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  3. klbx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  4. kmia Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  5. kpit Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  6. kcrw Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  7. paen Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  8. kast Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  9. kuin Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  10. kmht Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  11. kcys Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  12. kflo Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  13. pakn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  14. pabt Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  15. krdg Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  16. khdn Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  17. kjac Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  18. kphx Terminal Aerodrome Forecast

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TAF (terminal aerodrome forecast or terminal area forecast) is a format for reporting weather forecast information, particularly as it relates to aviation. TAFs are...

  19. Proportional counter end effects eliminator

    International Nuclear Information System (INIS)

    Meekins, J.F.

    1976-01-01

    An improved gas-filled proportional counter which includes a resistor network connected between the anode and cathode at the ends of the counter in order to eliminate ''end effects'' is described. 3 Claims, 2 Drawing Figures

  20. Defense Logistics Agency Revenue Eliminations

    National Research Council Canada - National Science Library

    1996-01-01

    The issue of revenue eliminations was identified during our work on the Defense Logistics Agency portion of the Audit of Revenue Accounts in the FY 1996 Financial Statements of the Defense Business Operations Fund...

  1. Experimental investigation of cobalt-60 accumulation and elimination in Cyprinus carpio (L.)

    International Nuclear Information System (INIS)

    Fritsch, A.F.

    1985-11-01

    When introduced in cation form, 60 Co showed a distinct tendency to form anion or neutral complexes (50% and 20%, respectively); this was favorized by a high biomass content per liter of water. The ionic evolution of the radionuclide did not affect its accumulation level in the fish. Direct contamination predominated (70%) and the concentration factor at equilibrium was 10. Nutritional transfer from Limnaea to carp, after ingestion of 45 contaminated rations in 63 days, resulted in a low radionuclide retention factor (3 x 10 -3 ) that was not subject to bioamplification. Cobalt-60 was primarily eliminated via urine (60%), while the fecal matter contained only 20% of the radioactive isotope ingested in the food. The 60 Co content of carp contaminated from the water increased proportionally with the temperature. However, the 60 Co concentration did not vary significantly with the thermal factor, and the radionuclide concentration factor ranged from 4 to 6 between 8 0 C and 25 0 C. Decontamination was generally a two-phase process characterized by a short biological half-life ( 60 Co contained in the fish. The high 60 Co content of the digestive tract may be explained by fecal excretion of the radioactive isotope (30-40% of the elimination). The kidneys act as radionuclide elimination regulators via the urinary system [fr

  2. Elimination reactions. V. Steric effects in Hofmann elimination

    International Nuclear Information System (INIS)

    Coke, J.L.; Smith, G.D.; Britton, G.H. Jr.

    1975-01-01

    Earlier Hofmann elimination studies were extended, and the percent syn eliminations in several ring systems have been correlated using cis-d 1 and trans-d 1 models. The measurements of several syn and anti k/sub H//k/sub D/ kinetic isotope effects are reported. Results indicate that Hofmann elimination of N,N,N-trimethyl-3,3-dimethylcyclopentylammonium hydroxide goes by 97 percent syn mechanism to give 3,3-dimethylcyclopentene and by 70 + - 6 percent syn mechanism to give 4,4-dimethylcyclopentene. There appears to be severe steric interactions in the anti mechanism in the 3,3-dimethylcyclopentyl system. Results indicate that, for Hofmann pyrolysis of trimethylammonium hydroxides, cyclopentene is formed by a 39 +- 7 percent syn mechanism, cyclohexene is formed by a 2 + - 2 percent syn mechanism, and cycloheptene is formed by a 30 +- 2 percent syn mechanism. Steric effects on isotope effects and mechanisms are discussed. (U.S.)

  3. CONTAINER TERMINALS IN EUROPE

    Directory of Open Access Journals (Sweden)

    Bart W. WIEGMANS

    2001-01-01

    Full Text Available This paper aims to address the linkage between logistics (in particular, the management of marketing channel flows and transport markets, while also the interaction between these two markets and intermodal container terminals is analysed. The marketing channel theory is used to describe all relevant actors and flows that run through marketing channels, starting with customer needs and ending with customer satisfaction. Porter's theory of competitive advantages is used to review competitive forces in both markets. Finally, a competitor analysis is performed for the logistics and transport market. These theories are applied so as to be able to determine the competitive position of intermodal container terminals with a view to the management of marketing channel flows and the physical transport of freight flows. Hence, the central question of this paper is: Which markets are served by intermodal container terminals and with whom are they competing? At present, neither the maritime container terminals nor the continental container terminals appear to have a significant influence in the logistics service market; they concentrate mainly on the physical movement of containers (transshipment. Furthermore, maritime container terminals and continental container terminals are not dominant players in the transport service market. Our conclusion is that continental terminals are predominantly competing with unimodal road transport, with neighbouring continental terminals and with barge transport companies.

  4. Lazy Productivity via Termination

    NARCIS (Netherlands)

    Endrullis, J.; Hendriks, R.D.A.

    2011-01-01

    We present a procedure for transforming strongly sequential constructor-based term rewriting systems (TRSs) into context-sensitive TRSs in such a way that productivity of the input system is equivalent to termination of the output system. Thereby automated termination provers become available for

  5. Termination of cycle rewriting

    NARCIS (Netherlands)

    Zantema, H.; König, B.; Bruggink, H.J.S.; Dowek, G.

    2014-01-01

    String rewriting can not only be applied on strings, but also on cycles and even on general graphs. In this paper we investigate termination of string rewriting applied on cycles, shortly denoted as cycle rewriting, which is a strictly stronger requirement than termination on strings. Most

  6. Kitimat LNG terminal

    International Nuclear Information System (INIS)

    Schmaltz, I.; Boulton, R.

    2007-01-01

    Kitimat Liquefied Natural Gas (LNG) terminal is a terminal development company owned by Galveston LNG, a privately owned Canadian energy development company. This presentation provided information on Kitimat LNG with particular reference to its terminal located in Bish Cove on the Douglas Channel in British Columbia. This LNG terminal is reported to be the only fully permitted regasification terminal on the west coast of Canada and the United States. The presentation addressed market fundamentals including several graphs, such as world natural gas proved reserves in 2006; LNG supplements to Canadian gas supplies; global LNG demand for 2005-2020; average annual United States LNG imports; and global LNG liquefaction projects. Other market fundamentals were described, including that Kitimat is the only other approved terminal aside from the Costa Azul terminal in Mexico; Kitimat is the only west coast LNG import terminal that connects to midwest and eastern North American markets through existing gas pipelines; LNG producers are looking for destination diversification; and markets and marketers are looking for supply diversification. The authors noted that by 2010, western Canadian gas demand will exceed Californian demand. Other topics that were discussed in the presentation included Canadian natural gas field receipts; unadjusted bitumen production outlook; oil sands gas demand; forward basis fundamentals; and the commercial drivers of the Kitimat LNG terminal. The presentation also discussed the pacific trail pipelines, a partnership between Galveston LNG and Pacific Northern Gas to develop the natural gas transmission line from Kitimat to Summit. The presentation concluded with a discussion of the benefits of Kitimat LNG terminal such as providing access to the largest natural gas markets in the world via major gas transmission lines with spare capacity. figs

  7. Cancer risks: Strategies for elimination

    International Nuclear Information System (INIS)

    Bannasch, P.

    1987-01-01

    This book deals with the possibilities for identifying and eliminating cancer risk factors. The current state of knowledge on the detection, assessment and elimination of chemical, physical (radiation), and biological (viruses) risk factors are comprehensively presented in 15 contributions. Chemical risk factors resulting from smoking and environmental contamination are given special attention. The coverage of cancer risks by radiation includes some of the consequences of the Chernobyl disaster. Finally, the discussion of the possible risks that certain viruses hold for cancer in man is intended to further the development of vaccinations against these viral infections. The information is directed not only at specialists, but also at a wider interested audience. Its primary aim is to convey established findings that are already being used for cancer prevention. Furthermore, the book aims to promote more intense research in the field of primary cancer prevention. Contents: General aspects; chemical carcinogens: Risk assessment; chemical carcinogens: Primary prevention; physical carcinogens - Oncogenic viruses and subject index

  8. How To Eliminate Narcissism Overnight

    Science.gov (United States)

    2011-01-01

    The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition appears likely to eliminate the diagnosis of narcissistic personality disorder. There are significant problems with the discriminant validity of the current narcissistic personality disorder critiera set; furthermore, the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition's narrow focus on “grandiosity” probably contributes to the wide disparity between low narcissistic personality disorder prevalence rates in epidemiological studies and high rates of narcissistic personality disorder in clinical practice. Nevertheless, the best course of action may be to refine the narcissistic personality disorder criteria, followed by careful field testing and a search for biomarkers, rather than wholesale elimination of the narcissistic personality disorder category. The construct of “malignant narcissism” is also worthy of more intense empirical investigation. PMID:21468294

  9. Challenges beyond elimination in leprosy.

    Science.gov (United States)

    Naaz, Farah; Mohanty, Partha Sarathi; Bansal, Avi Kumar; Kumar, Dilip; Gupta, Umesh Datta

    2017-01-01

    Every year >200,000 new leprosy cases are registered globally. This number has been fairly stable over the past 8 years. The World Health Organization has set a target to interrupt the transmission of leprosy globally by 2020. It is important, in terms of global action and research activities, to consider the eventuality of multidrug therapy (MDT) resistance developing. It is necessary to measure disease burden comprehensively, and contact-centered preventive interventions should be part of a global elimination strategy. Drug resistance is the reduction in effectiveness of a drug such as an antimicrobial or an antineoplastic in curing a disease or condition. MDT has proven to be a powerful tool in the control of leprosy, especially when patients report early and start prompt treatment. Adherence to and its successful completion is equally important. This paper has reviewed the current state of leprosy worldwide and discussed the challenges and also emphasizes the challenge beyond the elimination in leprosy.

  10. Modeling neuropeptide transport in various types of nerve terminals containing en passant boutons.

    Science.gov (United States)

    Kuznetsov, I A; Kuznetsov, A V

    2015-03-01

    We developed a mathematical model for simulating neuropeptide transport inside dense core vesicles (DCVs) in axon terminals containing en passant boutons. The motivation for this research is a recent experimental study by Levitan and colleagues (Bulgari et al., 2014) which described DCV transport in nerve terminals of type Ib and type III as well as in nerve terminals of type Ib with the transcription factor DIMM. The goal of our modeling is validating the proposition put forward by Levitan and colleagues that the dramatic difference in DCV number in type Ib and type III terminals can be explained by the difference in DCV capture in type Ib and type III boutons rather than by differences in DCV anterograde transport and half-life of resident DCVs. The developed model provides a tool for studying the dynamics of DCV transport in various types of nerve terminals. The model is also an important step in gaining a better mechanistic understanding of transport processes in axons and identifying directions for the development of new models in this area. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Elimination of cetirizine following administration of multiple doses to exercised thoroughbred horses.

    Science.gov (United States)

    Knych, H K; Stanley, S D; Arthur, R M; McKemie, D S

    2016-10-01

    Cetirizine is an antihistamine used in performance horses for the treatment of hypersensitivity reactions and as such a withdrawal time is necessary prior to competition. The objective of the current study was to describe the disposition and elimination of cetirizine following oral administration in order to provide additional serum concentration data upon which appropriate regulatory recommendations can be established. Nine exercised thoroughbred horses were administered 0.4 mg/kg of cetirizine orally BID for a total of five doses. Blood samples were collected immediately prior to drug administration and at various times postadministration. Serum cetirizine concentrations were determined and selected pharmacokinetic parameters determined. The serum elimination half-life was 5.83 ± 0.841 h. Average serum cetirizine concentrations were still above the LOQ of the assay (0.05 ng/mL) at 48 h (final sample collected) postadministration of the final dose. © 2016 John Wiley & Sons Ltd.

  12. Analytical studies by activation. Part A and B: Counting of short half-life radio-nuclides. Part C: Analytical programs for decay curves; Etudes d'analyse par activation. Parties A et B: le comptage des radio-nucleides de periodes courtes. Partie C: programme de depouillement des courbes de decroissance

    Energy Technology Data Exchange (ETDEWEB)

    Junod, E [Commissariat a l' Energie Atomique Grenoble (France). Centre d' Etudes Nucleaires

    1966-03-01

    Part A and B: Since a radio-nuclide of short half-life is characterized essentially by the decrease in its activity even while it is being measured, the report begins by recalling the basic relationships linking the half-life the counting time, the counting rate and the number of particles recorded. The second part is devoted to the problem of corrections for counting losses due to the idle period of multichannel analyzers. Exact correction formulae have been drawn up for the case where the short half-life radionuclide is pure or contains only a long half-life radio-nuclide. By comparison, charts have been drawn up showing the approximations given by the so-called 'active time' counting and by the counting involving the real time associated with a measurement of the overall idle period, this latter method proving to be more valid than the former. A method is given for reducing the case of a complex mixture to that of a two-component mixture. Part C: The problems connected with the qualitative and quantitative analysis of the decay curves of a mixture of radioactive sources of which one at least has a short half-life are presented. A mathematical description is given of six basic processes for which some elements of Fortran programs are proposed. Two supplementary programs are drawn up for giving an overall treatment of problems of dosage in activation analysis: one on the basis of a simultaneous irradiation of the sample and of one or several known samples, the other with separate irradiation of the unknown and known samples, a dosimeter (activation, or external) being used for normalizing the irradiation flux conditions. (author) [French] Parties A et B: Un radionucleide de periode courte etant defini specialement par la decroissance de son activite pendant la duree meme du comptage, on rappelle en premiere partie de ce rapport les relations fondamentales qui lient periode, temps de comptage, taux de comptage et nombre d'impulsions enregistrees. La seconde partie

  13. Cs-137 accumulation and elimination by Gracilaria caudata alga and Abudefduf saxatilis fish. Compartmental analysis

    International Nuclear Information System (INIS)

    Mattiolo-Marchese, Sandra Regina

    1998-01-01

    From the ecological point of view, 137 Cs is a critical radionuclide because its physical half-life is long (30 years), and it has a high fission yield. Besides, it presents similar characteristics to sodium and potassium, fundamental elements for the living organisms, in great concentration in all cells. This work has as aim to study the 137 Cs accumulation and elimination by the alga Gracilaria caudata and by the fish Abudefduf saxatilis as well as to obtain the transfer constants of the 137 Cs from the water into the organisms. The concentration factor found for the fish was 5.6 +- 0.2 and for the alga, 13.0 +- 0,6. With 7 and 22 days, the fish and alga respectively had already eliminated half of the accumulated radionuclide. The 137 Cs ingestion efficiency by the fish was also studied and it was verified that the fish assimilated only 47.6 % of the cesium content in the food; and within of 4 days it had eliminated more than half of ingested cesium. A compartmental model was proposed to explain the distribution of cesium in the compartments (water - alga and water - fish). Data obtained from the experiments of 137 Cs accumulation and elimination were applied in the Ana Comp Program. This program permits the compartmental analysis, and quantifies the cesium distribution from the sea-water to the organisms, and vice versa, through the transfer constants (k). The Ana Comp Program also allowed to calculate the dose that one would receive by the consumption of fish contaminated by cesium. Levels of 137 Cs from the global fallout in environmental samples, from Sao Sebastiao, northern coast of Sao Paulo, (where the 'Centro de Biologia Marinha da Universidade de Sao Paulo - CEBIMar - USP' is located), were verified. (author)

  14. Nonleaking battery terminals.

    Science.gov (United States)

    Snider, W. E.; Nagle, W. J.

    1972-01-01

    Three different terminals were designed for usage in a 40 ampere/hour silver zinc battery which has a 45% KOH by weight electrolyte in a plastic battery case. Life tests, including thermal cycling, electrical charge and discharge for up to three years duration, were conducted on these three different terminal designs. Tests for creep rate and tensile strength were conducted on the polyphenylene oxide plastic battery cases. Some cases were unused and others containing KOH electrolyte were placed on life tests. The design and testing of nonleaking battery terminals for use with a KOH electrolyte in a plastic case are considered.

  15. Lysophosphatidic acid metabolism and elimination in cardiovascular disease

    Science.gov (United States)

    Salous, Abdelghaffar Kamal

    The bioactive lipids lysophosphatidic acid (LPA) and sphingosine 1-phosphate (S1P) are present in human and mouse plasma at a concentration of ~0.1-1 microM and regulate physiological and pathophysiological processes in the cardiovascular system including atherothrombosis, intimal hyperplasia, and immune function, edema formation, and permeability. PPAP2B, the gene encoding LPP3, a broad activity integral membrane enzyme that terminates LPA actions in the vasculature, has a single nucleotide polymorphism that been recently associated with coronary artery disease risk. The synthesis and signaling of LPA and S1P in the cardiovascular system have been extensively studied but the mechanisms responsible for their elimination are less well understood. The broad goal of this research was to examine the role of LPP3 in the termination of LPA signaling in models of cardiovascular disease involving vascular wall cells, investigate the role of LPP3 in the elimination of plasma LPA, and further characterize the elimination of plasma LPA. The central hypothesis is that LPP3 plays an important role in attenuating the pathological responses to LPA signaling and that it mediates the elimination of exogenously applied bioactive lipids from the plasma. These hypotheses were tested using molecular biological approaches, in vitro studies, synthetic lysophospholipid mimetics, modified surgical procedures, and mass spectrometry assays. My results indicated that LPP3 played a critical role in attenuating LPA signaling mediating the pathological processes of intimal hyperplasia and vascular leak in mouse models of disease. Additionally, enzymatic inactivation of lysophospholipids by LPP and PLA enzymes in the plasma was not a primary mechanism for the rapid elimination of plasma LPA and S1P. Instead, evidence strongly suggested a transcellular uptake mechanism by hepatic non-parenchymal cells as the predominant mechanism for elimination of these molecules. These results support a model in

  16. Nontraumatic terminal ileal perforation

    Directory of Open Access Journals (Sweden)

    Wani Rauf A

    2006-03-01

    Full Text Available Abstract Background There is still confusion and controversy over the diagnosis and optimal surgical treatment of non traumatic terminal ileal perforation-a cause of obscure peritonitis. Methods This study was a prospective study aimed at evaluating the clinical profile, etiology and optimal surgical management of patients with nontraumatic terminal ileal perforation. Results There were 79 cases of nontraumatic terminal ileal perforation; the causes for perforation were enteric fever(62%, nonspecific inflammation(26%, obstruction(6%, tuberculosis(4% and radiation enteritis (1%. Simple closure of the perforation (49% and end to side ileotransverse anastomosis(42% were the mainstay of the surgical management. Conclusion Terminal ileal perforation should be suspected in all cases of peritonitis especially in developing countries and surgical treatment should be optimized taking various accounts like etiology, delay in surgery and operative findings into consideration to reduce the incidence of deadly complications like fecal fistula.

  17. Terminated Multifamily Mortgages Database

    Data.gov (United States)

    Department of Housing and Urban Development — This dataset includes all terminated HUD Multifamily mortgages except those from the Hospital Mortgage Insurance Program. It includes the Holder and Servicer at the...

  18. Coal terminal directory

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The directory gives a comprehensive listing of the world's coal terminals, in a total of 50 countries including information on throughput, facilities, storage capacity, and vessel size limitation.

  19. Development of a terminal voltage stabilization system for the FOTIA ...

    Indian Academy of Sciences (India)

    Abstract. A terminal voltage stabilization system for the folded tandem ion accelerator (FOTIA) was developed and is in continuous use. The system achieves good voltage stabilization, eliminates ground loops and noise interference. It incorporates a correcting circuit for compensating the mains frequency variations in the ...

  20. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.