WorldWideScience

Sample records for temporary covered nitinol

  1. Evaluation of the Effects of Temporary Covered Nitinol Stent Placement in the Prostatic Urethra: Short-Term Study in the Canine Model

    International Nuclear Information System (INIS)

    Crisostomo, Veronica; Song, Ho Young; Maynar, Manuel; Sun, Fei; Soria, Federico; Lima, Juan Rafael; Yoon, Chang Jin; Uson-Gargallo, Jesus

    2007-01-01

    Purpose. To evaluate the effect of temporary stent placement on the canine prostatic urethra. Methods. Retrievable PTFE-covered nitinol stents were placed in the prostatic urethras of 8 beagle dogs under fluoroscopic guidance. Retrograde urethrography was obtained before and after stenting. Retrograde urethrography and endoscopy were performed 1 and 2 months after deployment. The endoscopic degree of hyperplasia was rated on a scale of 0 to 4 (0 absence, 4 = occlusion). On day 60, stents were removed and urethrography was performed immediately before euthanasia. Pathologic analysis was performed to determine the degree of glandular atrophy, periurethral fibrosis, and urethral dilation. Results. Stent deployment was technically successful in 7 animals, and failed in 1 dog due to a narrow urethral lumen. Complete migration was seen in 2 animals at 1 month, and an additional stent was deployed. On day 30, endoscopy showed slight hyperplasia (grade 1) in 3 animals. On day 60, moderate hyperplasia (grade 2) was evidenced in 4 cases. No impairment of urinary flow was seen during follow-up. Retrieval was technically easy to perform, and was successful in all dogs. The major histologic findings were chronic inflammatory cell infiltrates; prostate glandular atrophy, with a mean value of 1.86 (SD 0.90); periurethral fibrosis, with a mean ratio of 29.37 (SD 10.41); and dilatation of the prostatic urethra, with a mean ratio of 6.75 (SD 3.22). Conclusion. Temporary prostatic stent placement in dogs is safe and feasible, causing marked enlargement of the prostatic urethral lumen. Retrievable covered stents may therefore be an option for bladder outlet obstruction management in men

  2. Malignant duodenal obstructions: palliative treatment with covered expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Chul; Jung, Gyoo Sik; Lee, Sang Hee; Kim, Sung Min; Oh, Kyung Seung; Huh, Jin Do; Cho, Young Duk [College of Medicine, Kosin Univ, Pusan (Korea, Republic of); Song, Ho Young [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-04-01

    To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, and after-loading technique was used. Stent placement was technically successful in ten patients, and no procedural complications occuured. In one of two patients in whom there was technical failure, and in whom the obstructions were located in part III, the stent was placed transgastrically. Stent migration occurred in one patient four days after the procedure, and treatment involved the palcement of a second, uncovered, nitinol stent. After stent placement, symptoms improved in all patients. During follow-up, obstructive symptoms due to stent stenosis (n=1), colonic obstruction (n=1), and multiple small bowel obstruction (n=1) recurred in three patients. Two of these were treated by placing additional stents in the duodenum and colon, respectively. One of the eight patients in whom a stent was placed in the second portion of the duodenum developed jaundice. The patients died a mean 14 (median, 9) weeks after stent placement. The placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible, safe and effective for the palliative treatment of malignant

  3. Polyurethane-Covered Self-expandable Nitinol Stent for Malignant Biliary Obstruction: Preliminary Results

    International Nuclear Information System (INIS)

    Han, Young-Min; Hwang, Seung-Bae; Lee, Soo-Teik; Lee, Jeong-Min; Chung, Gyung-Ho

    2002-01-01

    Purpose: To evaluate the immediate and long-term results in ten patients with malignant biliary obstruction using a polyurethane-covered, self-expandable nitinol stent.Methods: A nitinol stent, fully covered with high-elasticity polyurethane, with an unconstrained diameter of 10 mm and a total length of 60-80 mm, was placed transhepatically under fluoroscopic guidance in ten patients. The length of the biliary obstruction varied between 30-50 mm. The follow-up examination included a clinical assessment, serum bilirubin measurement, and ultrasound examinations at one-month intervals in all patients. Results: Initial stent deployment was successful in eight patients. Two patients experienced proximal migration,which was solved by insertion of two, uncovered Wallstents. One patient had the stent removed after two weeks because of severe nausea and vomiting. One patient had delayed migration of the covered stent after 40 weeks. The follow-up duration was 3-40 weeks (Mean: 16.9 weeks). Seven patients died(3-26 weeks) and three patients survived (24-40 weeks). The bilirubin measurements in all patients had significantly decreased one week after stent insertion. The levels of amylase and lipase had did not increase after stent insertion. Conclusions: Apolyurethane-covered, self-expandable nitinol stent can be used effectively and safely in the treatment of malignant biliary obstruction. The preliminary results are favorable, but there is a need for further large studies to determine both long-term survival and patency

  4. Temporary placement of covered retrievable expandable nitinol stents with barbs in high-risk surgical patients with benign prostatic hyperplasia: work in progress.

    Science.gov (United States)

    Kim, Choung-Soo; Song, Ho-Young; Jeong, In Gab; Yeo, Hyun Jin; Kim, Eun-Young; Park, Jung-Hoon; Yoon, Chang Jin; Paick, Sung Hyun; Park, Sang Woo; Bae, Jae-Ik; Won, Je Hwan

    2011-10-01

    To report the use of a newly constructed, covered, retrievable, expandable nitinol stent with barbs to overcome the problem of stent migration associated with conventional covered prostatic expandable stents and to evaluate prospectively the technical feasibility and clinical effectiveness of the stents in patients with benign prostatic hyperplasia (BPH). A covered retrievable expandable nitinol stent with four barbs was placed with use of an 18-F stent delivery system in seven consecutive patients with symptomatic BPH who had high operative risks. Age range of patients was 62-83 years (mean 74 years). In cases in which the stent migrated, it was replaced with a stent with eight barbs. The stents were routinely removed 4 months after placement using a 21-F stent removal set. Stent placement was technically successful and well tolerated in six of the seven patients. The remaining patient needed a second stent placement after removal of the first stent. The stent with four barbs migrated into the urinary bladder in four patients (57%); three of these patients received a second stent with eight barbs with good results, and the fourth patient did not need further treatment because his symptoms improved. Routine removal of the stent 4 months after placement was performed in three of the seven patients with good results. Retrievable stents with eight barbs seem to overcome the problem of stent migration associated with conventional prostatic expandable stents. Preliminary results suggest that stents with barbs are both feasible and effective in patients with BPH. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  5. Polyorethaoe-covered nitinol strecker stents as primary palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Kanasaki, Shuzo; Furukawa, Akira; Kane, Teruyuki; Murata, Kiyoshi

    2000-01-01

    Purpose: To evaluate the clinical efficacy of the polyure-thane-covered Nitinol Strecker stent in the treatment of patients with malignant biliary obstruction.Methods: Twenty-three covered stents produced by us were placed in 18 patients with malignant biliary obstruction. Jaundice was caused by cholangiocarcinoma (n=5), pancreatic Cancer (n=6), gallbladder Cancer (n=4), metastatic lymph nodes (n=2), and tumor of the papilla (n=1).Resulrs: The mean patency period of the Stents was 37.5 weeks (5-106 weeks). Recurrent obstructive jaundice occurred in two patients (11%). Adequate biliary drainage over 50 weeks or until death was achieved in 17 of 18 patients (94.4%). Late cholangitis was observed in two patients whose stents bridged the ampulla of Vater. Other late severe complications were not encountered.Conclusion: Although more study is necessary, our results suggest the clinical efficacy of our covered Nitinol Strecker stent in the management of obstructive jaundice caused by malignant diseases.

  6. Successful Exclusion of a Large Femoropopliteal Aneurysm with a Covered Nitinol Stent

    International Nuclear Information System (INIS)

    Dorffner, Roland; Winkelbauer, Friedrich; Kettenbach, Joachim; Staudacher, Michael; Lammer, Johannes

    1996-01-01

    A 70-year-old woman presented with a large femoropopliteal aneurysm. A covered nitinol stent was implanted successfully and complete exclusion of the aneurysm was achieved. At follow-up 5 months later the stent was still patent and the patient was free of symptoms. However, moderate stenosis was seen at the proximal end of the stent

  7. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of Medicine, Masan (Korea, Republic of)

    2008-06-15

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction.

  8. Self-expandable polytetrafluoroethylene (PTFE)-covered nitinol stent for the palliative treatment of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Yoo, Oong; Jung, Gyoo Sik; Han, Byung Hoon; Shin, Dong Hoon; Ko, Ji Ho

    2008-01-01

    We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the follow-up, recurrent obstructive jaundice occurred in six cases; stent migration occurred in four cases and tumor overgrowth occurred in two cases. The survival rates were 97%, 80%, 67% and 59% at 1, 3, 6 and 9 months, respectively. The stent patency rates were 96%, 92%, 86% and 86% at 1, 3, 6 and 9 months, respectively. Self-expandable PTFE-covered nitinol stent placement seems to be technically feasible and effective for the palliative treatment of malignant biliary obstruction

  9. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    International Nuclear Information System (INIS)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho

    2007-01-01

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates

  10. Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young-Min; Kwak, Hyo-Sung; Jin, Gong-Yong; Lee, Seung-Ok; Chung, Gyung-Ho [Chonbuk National University Medical School and Hospital, Chonju (Korea, Republic of)

    2007-10-15

    We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of their lives. There were no immediate complications. Three patients demonstrated stent sludge occlusion that required PTBD (percutaneous transhepatic biliary drainage) irrigation. Two patients experienced delayed stent migration with stone formation at 7 and 27 weeks of follow-up, respectively. Stent insertion resulted in acute elevations of the amylase and lipase levels one day after stent insertion in 11 patients in spite of performing endoscopic sphincterotomy (4/6). The bilirubin levels were significantly reduced one week after stent insertion (p < 0.01). The 30-day mortality rate was 8% (3/37), and the survival rates were 49% and 27% at 20 and 50 weeks, respectively. The primary stent patency rates were 85%, and 78% at 20 and 50 weeks, respectively. The PTFE-covered self-expandable nitinol stent is safe to use with acceptable complication rates. This study is similar to the previous studies with regard to comparing the patency rates and survival rates.

  11. Percutaneous Palliation of Pancreatic Head Cancer: Randomized Comparison of ePTFE/FEP–Covered Versus Uncovered Nitinol Biliary Stents

    International Nuclear Information System (INIS)

    Krokidis, Miltiadis; Fanelli, Fabrizio; Orgera, Gianluigi; Tsetis, Dimitrios; Mouzas, Ioannis; Bezzi, Mario; Kouroumalis, Elias; Pasariello, Roberto; Hatzidakis, Adam

    2011-01-01

    The purpose of this study was to compare the clinical effectiveness of expanded polytetrafluoroethylene/fluorinated-ethylene-propylene (ePTFE/FEP)–covered stents with that of uncovered nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer. Eighty patients were enrolled in a prospective randomized study. Bare nitinol stents were used in half of the patients, and ePTFE/FEP–covered stents were used in the remaining patients. Patency, survival, complications, and mean cost were calculated in both groups. Mean patency was 166.0 ± 13.11 days for the bare-stent group and 234.0 ± 20.87 days for the covered-stent group (p = 0.007). Primary patency rates at 3, 6, and 12 months were 77.5, 69.8, and 69.8% for the bare-stent group and 97.5, 92.2, and 87.6% for the covered-stent group, respectively. Mean secondary patency was 123.7 ± 22.5 days for the bare-stent group and 130.3 ± 21.4 days for the covered-stent group. Tumour ingrowth occurred exclusively in the bare-stent group in 27.5% of cases (p = 0.002). Median survival was 203.2 ± 11.8 days for the bare-stent group and 247.0 ± 20 days for the covered-stent group (p = 0.06). Complications and mean cost were similar in both groups. Regarding primary patency and ingrowth rate, ePTFE/FEP–covered stents have shown to be significantly superior to bare nitinol stents for the palliation of malignant jaundice caused by inoperable pancreatic head cancer and pose comparable cost and complications. Use of a covered stent does not significantly influence overall survival rate; nevertheless, the covered endoprosthesis seems to offer result in fewer reinterventions and better quality of patient life.

  12. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  13. Treatment of a Ruptured Anastomotic Esophageal Stricture Following Bougienage with a Dacron-Covered Nitinol Stent

    International Nuclear Information System (INIS)

    Heindel, Walter; Gossmann, Axel; Fischbach, Roman; Michel, Olaf; Lackner, Klaus

    1996-01-01

    A patient suffering from esophagorespiratory fistula after bougienage of a benign stricture at the site of the anastomosis between a jejunal interposition and the esophagus was referred for interventional treatment. A prototype nitinol stent centrally covered with Dacron was implanted under regional anesthesia and fluoroscopic guidance. The self-expanding prosthesis dilated the stenosis completely and closed the fistula, with consequent improvement in respiratory and nutritional status and thus the general quality of life. The patient was able to eat and drink normally until death 3 months later due to progression of his underlying malignant disease

  14. Nitinol Esophageal Stents: New Designs and Clinical Indications

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Boos, Irene; Vetter, Sylvia; Strohm, Michael; Domschke, Sigurd

    1996-01-01

    Purpose: To evaluate the clinical use of covered and noncovered, knitted nitinol stents in patients presenting new stent indications. Methods: Self-expandable, knitted nitinol stents were implanted in four patients for treatment of dysphagia. In two patients who had malignant strictures and had esophago-respiratory fistulae and in one patient with an esophagocutaneous fistula, polytetrafluoroethylene (PTFE)-covered stents were implanted. One patient received a noncovered stent, but a retrograde approach through a percutaneous endoscopic gastrostomy (PEG) fistula had to be chosen for recanalization of an esophageal occlusion. Two patients received stents for treatment of benign strictures. Results: Recanalization of the stricture and stent implantation were performed under fluoroscopic control without any procedure-related morbidity or mortality. Dysphagia improved in all patients and the esophageal fistulae could be sealed off by covered stents. During a maximum follow-up of 18 months, there was no stent migration or esophageal perforation. Complications observed were stent stenosis due to food impaction (1/4) and benign stent stenosis (2/2). Most complications could be treated by the interventional radiologist. Conclusion: Self-expandable, covered Nitinol stents provide an option for the treatment of dysphagia combined with esophageal fistulae. In combination with interventional radiology techniques, even complex strictures are accessible. For benign strictures, the value of stent treatment has not yet been proven

  15. Follow-up of Temporary Implantable Nitinol Device (TIND) Implantation for the Treatment of BPH: a Systematic Review.

    Science.gov (United States)

    Bertolo, Riccardo; Fiori, Cristian; Amparore, Daniele; Porpiglia, Francesco

    2018-04-26

    The purpose of the present systematic review is to offer a narrative synthesis of the available literature regarding the role of the temporary implantable nitinol device (TIND) (Medi-Tate®; Medi-Tate Ltd., Or Akiva, Israel) for the treatment of benign prostatic hyperplasia (BPH)-related lower urinary tract symptoms (LUTS), specifically focusing on the follow-up data. Current available evidences are limited in this topic. Sample size of patients available for analysis is small. Moreover, the duration of follow-up period is intermediate and longer follow-up is required. At the available 3 years follow-up, the TIND implantation is safe, effective, and well tolerated. The extended follow-up of the first and only available cohort of patients who underwent TIND for LUTS related to BPH corroborated previous literature findings. Further studies are required in order to assess the durability of TIND outcomes over a longer follow-up, to better define the indications of this approach, and to demonstrate the advantages of second-generation device over the first.

  16. Placement of a covered self-expandable nitinol stent for bile duct stricture that caused by ischemic injury after transcatheter arterial chemoembolization in a patient with hepatocellular carcinoma: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Kweon; Seo, Tae Seok; Cha, In Ho; Huh, Sik; Byun, Kwan Soo [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2008-10-15

    The authors report here on a case of focal stricture in the common hepatic duct that was caused by ischemic bile duct injury after repeat TACE procedures for hepatocellular carcinoma, and the patient was successfully treated with a covered self-expandable nitinol stent.

  17. Medical uses of nitinol

    Energy Technology Data Exchange (ETDEWEB)

    Pelton, A.R.; Stoeckel, D.; Duering, T.W. [Nitinol Devices and Components - Cordis Corp., Fremont, CA (United States)

    2000-07-01

    The growth of nitinol in the medical industries has exploded in the past ten years. Patients and care providers have encouraged the transition from traditional open-surgical procedures, which require long hospital stays, to less-invasive techniques, which are often performed in out-patient clinics. This demand for minimally invasive procedures has allowed novel instrumentation and implants to be designed. An increasing number of these devices use nitinol as the critical component. Examples of medical applications range from orthodontic archwires and endoscopic instruments to endovascular stents. This paper will focus on key performance attributes of nitinol that make it an ideal material for medical applications. Specific applications will be introduced through their use of the enabling features. (orig.)

  18. Sodium Hypochlorite Treatment and Nitinol Performance for Medical Devices

    Science.gov (United States)

    Weaver, J. D.; Gutierrez, E. J.; Nagaraja, S.; Stafford, P. R.; Sivan, S.; Di Prima, M.

    2017-09-01

    Processing of nitinol medical devices has evolved over the years as manufacturers have identified methods of reducing surface defects such as inclusions. One recent method proposes to soak nitinol medical devices in a 6% sodium hypochlorite (NaClO) solution as a means of identifying surface inclusions. Devices with surface inclusions could in theory then be removed from production because inclusions would interact with NaClO to form a visible black material on the nitinol surface. To understand the effects of an NaClO soak on performance, we compared as-received and NaClO-soaked nitinol wires with two different surface finishes (black oxide and electropolished). Pitting corrosion susceptibility was equivalent between the as-received and NaClO-soaked groups for both surface finishes. Nickel ion release increased in the NaClO-soaked group for black oxide nitinol, but was equivalent for electropolished nitinol. Fatigue testing revealed a lower fatigue life for NaClO-soaked black oxide nitinol at all alternating strains. With the exception of 0.83% alternating strain, NaClO-soaked and as-received electropolished nitinol had similar average fatigue life, but the NaClO-soaked group showed higher variability. NaClO-soaked electropolished nitinol had specimens with the lowest number of cycles to fracture for all alternating strains tested with the exception of the highest alternating strain 1.2%. The NaClO treatment identified only one specimen with surface inclusions and caused readily identifiable surface damage to the black oxide nitinol. Damage from the NaClO soak to electropolished nitinol surface also appears to have occurred and is likely the cause of the increased variability of the fatigue results. Overall, the NaClO soak appears to not lead to an improvement in nitinol performance and seems to be damaging to the nitinol surface in ways that may not be detectable with a simple visual inspection for black material on the nitinol surface.

  19. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  20. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    International Nuclear Information System (INIS)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-01-01

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P   0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  1. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis.

    Science.gov (United States)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-08-01

    To evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis. We conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal. A total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P  0.05). Temporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  2. Temporary urethral covered stent - third year of experience

    International Nuclear Information System (INIS)

    Stojanovis, V.; Maksimovis, H.; Markovis, B.; Markovis, Z.

    2006-01-01

    Full text: In October 2003, a new generation of urethral stents ALLIUM, produced in Israel, were used at the Department of Interventional Radiology, CCS, in 18 patients with chronic stricture of bulbar urethra. The indications for insertion were determined according to well-known and recognized therapeutical protocols. The stent is made of nitinol wire with polyurethane cover. It is inserted under local anesthesia by a special self-expandable system that may be fixed or flexible. The stents we used were 3-6 cm long and 28 Fr wide. Radioscopic-assisted insertion was performed over formerly placed metal guide. Prior to insertion, balloon-catheter dilatation of stricture matching the stent width was carried out. Pre-insertion urethrotomy was performed in one case. The insertion technique is simple, presupposing the knowledge of older generations of techniques of urethral dilatation and insertion of self-expandable stents. The follow-up of results was done according to a priori established protocol including the following: UCG, uroflowmetry and interview with patients. Due to stent migration, the 'stent over stent' technique was applied in one case, while reposition by balloon-catheter outward traction was performed in two cases of caudal migration. No irritative discomforts were reported in the first 4 months after stent dwelling. Uroflowmetric controls verified at least four times better results than before the insertion. Given it is the question of covered stent, there is no possibility of proliferative secondary lumen obstruction. On account of soft structure and conic shape of posterior part of stent, no lesions of the external urethral sphincter were manifested. The stent is simply withdrawn after 6 months by outward traction using the forceps at the time when the stent construction turns into soft and straight wire. The first clinical experiences are very favorable and ALLIUM stent may be expected to be the stent of choice for chronic bulbar strictures

  3. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    International Nuclear Information System (INIS)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja; Jung, Gyoo Sik

    2005-01-01

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  4. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja [College of Medicine, Kosin University, Busan (Korea, Republic of); Jung, Gyoo Sik [Ulsan Hospital, Ulsan (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  5. Extensive caustic esophageal stricture in children can be treated by serial dilatations interspersed with silicone-covered nitinol stenting

    Directory of Open Access Journals (Sweden)

    Veronica Alonso

    2016-01-01

    Full Text Available Recurrent esophageal stenosis secondary to caustic ingestion may be challenging to treat. Self-expandable esophageal stents may be an alternative to repetitive endoscopic esophageal dilatation. We report a case of a 2-year-old male child with an extensive esophageal caustic stricture successfully treated using a combination of endoscopic dilatation and stenting. After 5 months of serial balloon dilatations, three nitinol internal silicone covered self-expandable stents were placed through the patient′s gastrostomy spanning the entire esophagus. The stents were positioned using a combination of both endoscopic and fluoroscopic guidance. The procedure was repeated with only one stent 3 months later. A new stricture in the proximal esophagus needed surgical resection and anastomosis, followed by two pneumatic dilatations with progressively longer asymptomatic intervals. The results are promising with the patient able to use his own esophagus; however, this is a single case and optimal stent standing time is still to be determined.

  6. Simon-nitinol filter

    International Nuclear Information System (INIS)

    Simon, M.; Kim, D.; Porter, D.H.; Kleshinski, S.

    1989-01-01

    This paper discusses a filter that exploits the thermal shape-memory properties of the nitinol alloy to achieve an optimized filter shape and a fine-bore introducer. Experimental methods and materials are given and results are analyzed

  7. Investigation Of Interaction Between Nitinol Stent And A Vascular Plaque Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Recep Güneş

    2012-06-01

    Full Text Available In this study, the interaction between the Nitinol stent and the artery with plaque was investigated using finite element method. The occurring pressure values during the cardiac contraction (systolic and loosening (diastolic were applied as loading to the modeled system with Nitinol stent. In the light of the stress values, the suitability of the Nitinol stent in an artery with plaque was investigated. In the analysis, Nitinol stent was assumed to be shape memory alloy, and artery and plaque were assumed to behave linearly elastic. As a result, the stress and deformations in the plaque and artery due to the interference of Nitinol stent were discussed and concluded that the structure of artery with plaque can be expanded in accordance with Nitinol stent.

  8. Nitinol: Tubing versus sputtered film - microcleanliness and corrosion behavior.

    Science.gov (United States)

    Wohlschlögel, Markus; Lima de Miranda, Rodrigo; Schüßler, Andreas; Quandt, Eckhard

    2016-08-01

    Corrosion behavior and microcleanliness of medical-device grade Nitinol tubing (Nix Ti1- x , x = 0.51; outer diameter 7 mm, wall thickness 0.5 mm), drawn from various ingot qualities, are compared to the characteristics of sputtered Nitinol film material (Nix Ti1- x , x = 0.51; thickness 50 µm). Electropolished tubing half-shell samples are tested versus as-received sputtered film samples. Inclusion size distributions are assessed using quantitative metallography and corrosion behavior is investigated by potentiodynamic polarization testing in phosphate-buffered saline at body temperature. For the sputtered film samples, the surface chemistry is additionally analyzed employing Auger Electron Spectroscopy (AES) composition-depth profiling. Results show that the fraction of breakdowns in the potentiodynamic polarization test correlates with number and size of the inclusions in the material. For the sputtered Nitinol film material no inclusions were detectable by light microscopy on the one hand and no breakdowns were found in the potentiodynamic polarization test on the other hand. As for electropolished Nitinol, the sputtered Nitinol film material reveals Nickel depletion and an Oxygen-to-Titanium intensity ratio of ∼2:1 in the surface oxide layer, as measured by AES. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1176-1181, 2016. © 2015 Wiley Periodicals, Inc.

  9. Sealed source and device design safety testing: Technical report on the findings of task 4 -- Investigation of failed Nitinol brachytherapy wire. Volume 2

    International Nuclear Information System (INIS)

    Benac, D.J.; Burghard, H.C.

    1996-03-01

    This report covers an investigation of the nature and cause of failure in Nitinol brachytherapy sourcewires. The investigation was initiated after two clinical incidents in which sourcewires failed during or immediately after a treatment. The investigation determined that the two clinical Nitinol sourcewires failed in a brittle manner, which is atypical for Nitinol. There were no material anomalies or subcritical flaws to explain the brittle failures. The bend tests also demonstrated that neither moist environment, radiation, nor low-temperature structural transformation was a likely root cause of the failures. However, degradation of the PTFE was consistently evident, and those sourcewires shipped or stored with PTFE sleeves consistently failed in laboratory bend tests. On the basis of the results of this study, it was concluded that the root cause of the in-service failures of the sourcewires was environmentally induced embrittlement due to the breakdown of the PTFE protective sleeves in the presence of the high-radiation field and subsequent reaction or interaction of the breakdown products with the Nitinol alloy

  10. Temporary implantable nitinol device (TIND): a novel, minimally invasive treatment for relief of lower urinary tract symptoms (LUTS) related to benign prostatic hyperplasia (BPH): feasibility, safety and functional results at 1 year of follow-up.

    Science.gov (United States)

    Porpiglia, Francesco; Fiori, Cristian; Bertolo, Riccardo; Garrou, Diletta; Cattaneo, Giovanni; Amparore, Daniele

    2015-08-01

    To report the first clinical experience with a temporary implantable nitinol device (TIND; Medi-Tate(®) ) for the treatment of lower urinary tract symptoms (LUTS) due to benign prostatic hyperplasia (BPH). In all, 32 patients with LUTS were enrolled in this prospective study, which was approved by our Institutional Ethics Committee. Inclusion criteria were: age >50 years, International Prostate Symptom Score (IPSS) of ≥10, maximum urinary flow rate (Qmax ) of ≤12 mL/s, and prostate volume of BPH. TIND implantation is a feasible and safe minimally invasive option for the treatment of BPH-related LUTS. The functional results are encouraging and the treatment significantly improved patient QoL. Further studies are required to assess durability of TIND results and to optimise the indications of such a procedure. © 2014 The Authors BJU International © 2014 BJU International Published by John Wiley & Sons Ltd.

  11. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ji; Han, Xinwei, E-mail: hanxinwei2006@163.com; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua [The First Affiliated Hospital of Zhengzhou University, Department of Interventional Radiology (China)

    2016-08-15

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P < 0.05). The mean lumen transverse diameters of the stenotic site in trachea and main bronchus after stent removal (17.235 ± 3.457 and 8.993 ± 0.961 mm; 1 month post-removal; 16.353 ± 4.132 and 8.357 ± 1.082 mm; 6 months post-removal) were significantly larger than those before stent placement (7.876 ± 2.351 and 2.143 ± 0.770 mm, respectively; P < 0.05). However, the mean lumen diameters between 1 and 6 months after stent removal had no significant difference (P > 0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  12. Endoscopically placed nitinol stents for pediatric tracheal obstruction.

    Science.gov (United States)

    Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M

    2002-11-11

    To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland

  13. Distribution of nickel after modified nitinol stent implantation in animals

    Science.gov (United States)

    Chepeleva, E.; Sergeevichev, D.; Lotkov, A.; Kashin, O.; Korobeynikov, A.; Kozyr, K.; Baystrukov, V.; Zubarev, D.; Kretov, E.; Pokushalov, E.

    2017-09-01

    Intravascular stenting of arteries in atherosclerotic lesions is one of the most frequently performed procedures in cardiovascular surgery today. Most stents are made of various stainless-steel alloys and other metals (such as nitinol). Nitinol is a biocompatible, superplastic and corrosion resistant material with an important feature of shape memory. However, the composition of this alloy includes nickel, which shows toxicity to the kidneys, liver, lungs, heart and other organs when it accumulates in the organism. In this research we investigated the nickel content in serum, urine and hair of the laboratory animals after implantation of nitinol stents treated with plasma ionic surface modification by silicon.

  14. Recent observations of particulates in Nitinol

    International Nuclear Information System (INIS)

    Shabalovskaya, S.; Anderegg, J.; Humbeeck, J. van

    2008-01-01

    In spite of 40 years of history of Nitinol, the issues regarding its inclusions have been poorly explored. In our brief studies, conducted within the projects on surface design using Auger, energy-dispersive X-ray spectroscopy and scanning electrons microscopy, we discovered that particulates in NiTi medical alloys were always based on Ti: either ∼Ti 2 NiO oxide, titanium dioxide, titanium carbide or oxidized titanium carbide. Nonmetallic particles were rather brittle, had various shapes and sizes, and revealed different solubility in chemical solutions. The matrix material surrounding inclusions showed a tendency to localized corrosion. It was hypothesized that release of inclusion debris in the human body due to corrosion might compromise biocompatibility of Nitinol

  15. [NITINOL shape memory staple for osteosynthesis of the scaphoid].

    Science.gov (United States)

    Winkel, Reiner; Schlageter, Michael

    2009-11-01

    Reconstruction of the scaphoid with use of NITINOL shape "memory" staples. Unstable fractures and nonunion of the middle third of the scaphoid, which need open reduction and internal fixation from palmar. The staples can only be used, if the arms of the staples can be inserted parallel to and at a distance of 3 mm to the fracture line. Allergy to nickel. Cases in which the arms of the staple cannot be inserted parallel to and at best 3 mm apart from the fracture line. In fractures, open reduction of the scaphoid through a palmar approach. If necessary, interposition of a bone graft and Kirschner wire transfixation. Drilling of the drill holes parallel and at a distance of 3 mm to the fracture line. Insertion of the NITINOL staple. In nonunion, excision of the fibrous nonunion, refreshening of the fracture surfaces, interposition of a bone graft and, if needed, fixation with a Kirschner wire. Drilling of the drill holes for the NITINOL staple and insertion of the staple. Within a few minutes the warming-up staple contracts and thereby compresses the scaphoid. Immobilization in a short cast with thumb support for 6 weeks. Control for bone healing by radiographs or computed tomography. Staples, which do not cause hardware problems, are not removed. Kirschner wires are removed after bone healing. From October 1995 to December 2006, the authors used NITINOL staples for 65 osteosyntheses of the scaphoid. Indications were 15 unstable fractures, 47 nonunions, and three partial necroses. 61 out of 65 scaphoids healed without further surgery, three of the 61 patients showed a delayed healing. Two of the four nonunions were related to the use of the NITINOL staples. Seven staples were removed, one for loosening. NITINOL shape memory staples have proven to be very helpful for osteosynthesis in fractures and nonunion of the scaphoid, if the prerequisites are given for their use.

  16. Fatigue of Nitinol: The state-of-the-art and ongoing challenges.

    Science.gov (United States)

    Mahtabi, M J; Shamsaei, Nima; Mitchell, M R

    2015-10-01

    Nitinol, a nearly equiatomic alloy of nickel and titanium, has been considered for a wide range of applications including medical and dental devices and implants as well as aerospace and automotive components and structures. The realistic loading condition in many of these applications is cyclic; therefore, fatigue is often the main failure mode for such components and structures. The fatigue behavior of Nitinol involves many more complexities compared with traditional metal alloys arising from its uniqueness in material properties such as superelasticity and shape memory effects. In this paper, a review of the present state-of-the-art on the fatigue behavior of superelastic Nitinol is presented. Various aspects of fatigue of Nitinol are discussed and microstructural effects are explained. Effects of material preparation and testing conditions are also reviewed. Finally, several conclusions are made and recommendations for future works are offered. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Self-expanding nanoplatinum-coated nitinol devices for atrial septal defect and patent ductus arteriosus closure: a swine model.

    Science.gov (United States)

    Lertsapcharoen, Pornthep; Khongphatthanayothin, Apichai; La-orkhun, Vidhavas; Supachokchaiwattana, Pentip; Charoonrut, Phingphol

    2006-01-01

    Our purpose was to evaluate self-expanding nanoplatinum-coated nitinol devices for transcatheter closure of atrial septal defects and patent ductus arteriosus in a swine model. The devices were braided from platinum-activated nitinol wires and filled with polyester to enhance thrombogenicity. The platinum activation of the nitinol wires was carried out with the help of Nanofusion technology. The coating of platinum covers the exposed surface of the nitinol wires and prevents the release of nickel into the blood stream after the implantation of the device but does not affect its shape memory, which makes the device self-expanding after it is loaded from the catheter. Atrial septal defects were created in 12 piglets by balloon dilation of the patent foramen ovale. The size of the device was selected on the basis of the diameter of the balloon and the size of the defect, measured by transthoracic echocardiography. The devices were successfully deployed in all 12 piglets under fluoroscopic study. Transthoracic color Doppler echocardiograms showed complete closure of the atrial septal defect within 15 minutes of device implantation. Twelve patent ductus arteriosus closure devices were deployed in the right or left subclavian arteries in 10 piglets. Angiograms showed complete occlusion of the subclavian arteries within a few minutes of device deployment. In the atrial septal defect cases, the autopsy findings showed complete organizing fibrin thrombus formation and complete neo-endothelialization on the outer surface of the devices within one week and six weeks of implantation, respectively. The use of self-expanding nanoplatinum-coated nitinol devices for the transcatheter closure of atrial septal defects and patent ductus arteriosus is feasible. The excellent occlusion result and complete neo-endothelialization of the devices in the swine model is an indication of the potential of these devices in human application.

  18. Physical properties of a new type of self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Soo [Seoul Health College, Seoul (Korea, Republic of); Kim, Tae Hyung; Song, Sang Woo; Kang, Seong Gwon; Huh, Soo Jin; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of); Kim, Eun Sang [Stentech, Inc., Seoul (Korea, Republic of); Kim, Cheol Saeng [Solco Surgical Instruments Co., Ltd, Seoul (Korea, Republic of)

    1999-08-01

    To study the new physical properties including hoop strength and flexibility of a newly developed nitinol stent. The new stent was made of a single nitinol wire 0.15 - 0.25 mm in diameter. This was wound around a cylindrical metallic jig with a constant angle to the longitudinal direction, and stents which winding were constructed. Hoop strength of the stents was measured with a spring gauge and compared with that of Wallstent and Hanaro stents. The flexibility of the new stent was evaluated on the basis of changes in stent diameter when bent in the direction of 180 deg Hoop strength of the new nitinol stent was proportional to 3.8 ({+-}0.3)-th power of the wire thickness. A greater number of wires on a lateral cut surface or a greater number of longitudinal windings also resulted in increased strength. However, the former caused an increase in total wire area and the latter resulted increased stent length when compressed. Hoop strength of the new nitinol stent was superior to that of Wallstent and Hanaro stents, and stent diameter did not decrease when the stent was bent in the direction of 180 degrees. Hoop strength of the new nitinol stent was most significantly affected by wire thickness. The stent was very flexible and thus seemed suitable for an angled lumen.

  19. The corrosion resistance of Nitinol alloy in simulated physiological solutions

    International Nuclear Information System (INIS)

    Milošev, Ingrid; Kapun, Barbara

    2012-01-01

    The corrosion behaviour of Nitinol alloy containing nearly equi-atomic composition of nickel and titanium and its constituent metals (nickel and titanium) was investigated in simulated Hanks physiological solution (pH value 7.5) and pH modified simulated Hanks physiological solution (pH values 4.5 and 6.5) and by electrochemical method of anodic potentiodynamic polarization at 37 °C. In this chloride-rich medium the corrosion stability of Nitinol is limited by the susceptibility to localized corrosion and is in that sense more similar to nickel than to titanium. The corrosion stability of Nitinol is strongly dependent on the surface preparation—grinding, polishing or chemical etching. Whereas a ground surface is not resistant to localized corrosion, polished and chemically etched surfaces are resistant to this type of corrosion attack. The reasons for this behaviour were investigated through metallurgical, topographical and chemical properties of the surface as a function of surface preparation. For that purpose, scanning electron microscopy combined with chemical analysis, confocal microscopy and X-ray photoelectron spectroscopy were used. The surface roughness decreased in the following order: chemically etched > ground > polished surface. Besides differences in topography, distinct differences in the chemical composition of the outermost surface are observed. Ground, rough surfaces comprised mainly titanium oxides and small amounts of nickel metal. Chemically etched and, especially, polished surfaces are composed of a mixture of titanium, nickel and titanium oxides, as studied by angle resolved X-ray photoelectron spectroscopy. These results emphasize the importance of detailed investigation of the metal surface since small differences in surface preparation may induce large differences in corrosion stability of material when exposed to corrosive environments. - Highlights: ► The corrosion resistance of Nitinol is dependent on the surface preparation.

  20. Feasibility study for the investigation of Nitinol self-expanding stents by neutron techniques

    International Nuclear Information System (INIS)

    Rogante, M.; Pasquini, U.; Rosta, L.; Lebedev, V.

    2011-01-01

    In this paper, neutron techniques - in particular, small angle neutron scattering (SANS) and neutron diffraction (ND) - are considered for the non-destructive characterization of Nitinol artery stents. This roughly equiatomic (50Ni-50Ti at%) shape memory alloy (SMA) exhibits significant properties of superelasticity and biocompatibility that make it suitable to be typically used as smart material for medical implants and devices. Nitinol self-expanding artery stents, as permanent vascular support structures, supply an ideal option to bypass surgery, but they are submitted for the whole of patient's life to the dynamical stress of the artery pulsation and the aggression from the biological environment. These stents, consequently, can suffer from wear and fracture occurrence likely due to a variety of cyclic fatigue, overload conditions and residual stresses. Neutrons have recently become a progressively more important probe for various materials and components and they allow achieving information complementary to those obtained from the traditional microstructural analyses. The outputs from the preliminary works already carried out in this field consent to consider neutron techniques capable to contribute to the development of these crucial medical implants. The achievable results can yield trends adoptable in monitoring of the stent features. -- Research Highlights: → Neutron techniques can contribute to develop Nitinol self-expanding artery stents. → Neutrons investigations can help avoiding wear and fracture events in Nitinol stents. → Neutron techniques can yield trends adoptable in monitoring of Nitinol stent features. → SANS is able to perform a micro- and nano-scale characterization of Nitinol stents. → Neutron Diffraction helps assessing stresses due to the exercise in Nitinol stents.

  1. Results of the new nitinol self-expandable stents for distal biliary structures

    NARCIS (Netherlands)

    Smits, M.; Huibregtse, K.; Tytgat, G.

    1995-01-01

    The nitinol stent is a self-expandable spiral stent made of nickel-titanium alloy. We performed a pilot study to evaluate the method of stent insertion and stent efficacy. Twenty-eight patients with irresectable malignancy had nitinol stents inserted for obstructive jaundice due to distal biliary

  2. The effects of Nitinol phases on corrosion and fatigue behavior

    Science.gov (United States)

    Denton, Melissa

    The purpose of these studies was to provide a detailed understanding of Nitinol phases and their effects on corrosion and fatigue life. The two primary phases, austenite and martensite, were carefully evaluated with respect to material geometry, corrosion behavior, wear, and fatigue life. Material characterization was performed using several techniques that include metallography, scanning electron microscopy (SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM), x-ray photoelectron spectrum (XPS), and Auger electron spectroscopy (AES). Uniaxial tensile tests were conducted to determine the mechanical properties such as elongation, ultimate tensile strength, modulus, transformation strain, and plateau stress. In addition, accelerated wear testing and four point bend fatigue testing were completed to study the fatigue life and durability of the material. The corrosion of Nitinol was found to be dependent on various surface conditions. Electrochemical corrosion behavior of each phase was investigated using cyclic potentiodyamic polarization testing. The corrosion response of electropolished Nitinol was found to be acceptable, even after durability testing. Stress-induced martensite had a lower breakdown potential due to a rougher surface morphology, while thermally induced martensite and austenite performed similarly well. The surface conditioning also had a significant effect on Nitinol mechanical properties. Electropolishing provided a smooth mirror finish that reduced localized texture and enhanced the ductility of the material. Quasi-static mechanical properties can be good indicators of fatigue life, but further fatigue testing revealed that phase transformations had an important role as well. The governing mechanisms for the fatigue life of Nitinol were determined to be both martesitic phase transformations and surface defects. A new ultimate dislocation strain model was proposed based on specific accelerated step-strain testing.

  3. Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots.

    Science.gov (United States)

    Gilbert, Hunter B; Webster, Robert J

    Shape setting Nitinol tubes and wires in a typical laboratory setting for use in superelastic robots is challenging. Obtaining samples that remain superelastic and exhibit desired precurvatures currently requires many iterations, which is time consuming and consumes a substantial amount of Nitinol. To provide a more accurate and reliable method of shape setting, in this paper we propose an electrical technique that uses Joule heating to attain the necessary shape setting temperatures. The resulting high power heating prevents unintended aging of the material and yields consistent and accurate results for the rapid creation of prototypes. We present a complete algorithm and system together with an experimental analysis of temperature regulation. We experimentally validate the approach on Nitinol tubes that are shape set into planar curves. We also demonstrate the feasibility of creating general space curves by shape setting a helical tube. The system demonstrates a mean absolute temperature error of 10°C.

  4. On the Mechanical Properties and Microstructure of Nitinol forBiomedical Stent Applications

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Scott W. [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    This dissertation was motivated by the alarming number of biomedical device failures reported in the literature, coupled with the growing trend towards the use of Nitinol for endovascular stents. The research is aimed at addressing two of the primary failure modes in Nitinol endovascular stents: fatigue-crack growth and overload fracture. The small dimensions of stents, coupled with their complex geometries and variability among manufacturers, make it virtually impossible to determine generic material constants associated with specific devices. Instead, the research utilizes a hybrid of standard test techniques (fracture mechanics and x-ray micro-diffraction) and custom-designed testing apparatus for the determination of the fracture properties of specimens that are suitable representations of self-expanding Nitinol stents. Specifically, the role of texture (crystallographic alignment of atoms) and the austenite-to-martensite phase transformation on the propagation of cracks in Nitinol was evaluated under simulated body conditions and over a multitude of stresses and strains. The results determined through this research were then used to create conservative safe operating and inspection criteria to be used by the biomedical community for the determination of specific device vulnerability to failure by fracture and/or fatigue.

  5. Laser shape setting of superelastic nitinol wires: Functional properties and microstructure

    Science.gov (United States)

    Tuissi, Ausonio; Coduri, Mauro; Biffi, Carlo Alberto

    Shape setting is one of the most important steps in the production route of Nitinol Shape Memory Alloys (SMAs), as it can fix the functional properties, such as the shape memory effect and the superelasticity (SE). The conventional method for making the shape setting is performed at 400-500∘C in furnaces. In this work, a laser beam was adopted for performing straight shape setting on commercially available austenitic Nitinol thin wires. The laser beam, at different power levels, was moved along the wire length for inducing the functional performances. Calorimetric, pseudo-elastic and microstructural features of the laser annealed wires were studied through differential scanning calorimetry, tensile testing and high energy X-ray diffraction, respectively. It can be stated that the laser technology can induce SE in thin Nitinol wires: the wire performances can be modulated in function of the laser power and improved functional properties can be obtained.

  6. Adhesion, vitality and osteogenic differentiation capacity of adipose derived stem cells seeded on nitinol nanoparticle coatings.

    Directory of Open Access Journals (Sweden)

    Sarah Strauss

    Full Text Available Autologous cells can be used for a bioactivation of osteoimplants to enhance osseointegration. In this regard, adipose derived stem cells (ASCs offer interesting perspectives in implantology because they are fast and easy to isolate. However, not all materials licensed for bone implants are equally suited for cell adhesion. Surface modifications are under investigation to promote cytocompatibility and cell growth. The presented study focused on influences of a Nitinol-nanoparticle coating on ASCs. Possible toxic effects as well as influences on the osteogenic differentiation potential of ASCs were evaluated by viability assays, scanning electron microscopy, immunofluorescence and alizarin red staining. It was previously shown that Nitinol-nanoparticles exert no cell toxic effects to ASCs either in soluble form or as surface coating. Here we could demonstrate that a Nitinol-nanoparticle surface coating enhances cell adherence and growth on Nitinol-surfaces. No negative influence on the osteogenic differentiation was observed. Nitinol-nanoparticle coatings offer new possibilities in implantology research regarding bioactivation by autologous ASCs, respectively enhancement of surface attraction to cells.

  7. Nano-Impact (Fatigue Characterization of As-Deposited Amorphous Nitinol Thin Film

    Directory of Open Access Journals (Sweden)

    Rehan Ahmed

    2012-08-01

    Full Text Available This paper presents nano-impact (low cycle fatigue behavior of as-deposited amorphous nitinol (TiNi thin film deposited on Si wafer. The nitinol film was 3.5 µm thick and was deposited by the sputtering process. Nano-impact tests were conducted to comprehend the localized fatigue performance and failure modes of thin film using a calibrated nano-indenter NanoTest™, equipped with standard diamond Berkovich and conical indenter in the load range of 0.5 mN to 100 mN. Each nano-impact test was conducted for a total of 1000 fatigue cycles. Depth sensing approach was adapted to understand the mechanisms of film failure. Based on the depth-time data and surface observations of films using atomic force microscope, it is concluded that the shape of the indenter test probe is critical in inducing the localized indentation stress and film failure. The measurement technique proposed in this paper can be used to optimize the design of nitinol thin films.

  8. Use of nitinol self-expandable stents in 26 dogs with tracheal collapse.

    Science.gov (United States)

    Beranek, J; Jaresova, H; Rytz, U

    2014-02-01

    A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

  9. Addressing Machining Issues for the Intermetallic Compound 60-NITINOL

    Science.gov (United States)

    Stanford, Malcolm K.; Wozniak, Walter A.; McCue, Terry R.

    2012-01-01

    60-NITINOL (60 wt.% Ni - 40 wt.% Ti) is being studied as a material for advanced aerospace components. Frequent wire breakage during electrical-discharge machining of this material was investigated. The studied material was fabricated from hot isostatically pressed 60-NITINOL powder obtained through a commercial source. Bulk chemical analysis of the material showed that the composition was nominal but had relatively high levels of certain impurities, including Al and O. It was later determined that Al2O3 particles had contaminated the material during the hot isostatic pressing procedure and that these particles were the most likely cause of the wire breakage. The results of this investigation highlight the importance of material cleanliness to its further implementation.

  10. On the Electrodeposition of Ca-P Coatings on Nitinol Alloy: A Comparison Between Different Surface Modification Methods

    Science.gov (United States)

    Etminanfar, M. R.; Khalil-Allafi, J.

    2016-02-01

    In this study, a combination of surface modification process and the electrochemical deposition of Ca-P coatings was used for the modification of the Nitinol shape memory alloy. DSC, SEM, GIB-XRD, FT-Raman, XPS, and FTIR measurements were performed for the characterization of the samples. Results indicated that chemical etching and boiling of the samples in distilled water formed TiO film on the surface. After the chemical modification, subsequent aging of the sample, at 470 °C for 30 min, converted the oxide film to a stable structure of titanium dioxide. In that case, the treated substrate indicated a superelastic behavior. At the same electrochemical condition, the treated substrate revealed more stable and uniform Ca-P coatings in comparison with the abraded Nitinol substrate. This difference was attributed to the presence of hydroxyl groups on the titanium dioxide surface. Also, after soaking the sample in SBF, the needle-like coating on the treated substrate was completely covered with the hydroxyapatite phase which shows a good bioactivity of the coating.

  11. Statistical characteristics of surface integrity by fiber laser cutting of Nitinol vascular stents

    International Nuclear Information System (INIS)

    Fu, C.H.; Liu, J.F.; Guo, Andrew

    2015-01-01

    Graphical abstract: - Highlights: • Precision kerf with tight tolerance of Nitinol stents can be cut by fiber laser. • No HAZ in the subsurface was detected due to large grain size. • Recast layer has lower hardness than the bulk. • Laser cutting speed has a higher influence on surface integrity than laser power. - Abstract: Nitinol alloys have been widely used in manufacturing of vascular stents due to the outstanding properties such as superelasticity, shape memory, and superior biocompatibility. Laser cutting is the dominant process for manufacturing Nitinol stents. Conventional laser cutting usually produces unsatisfactory surface integrity which has a significant detrimental impact on stent performance. Emerging as a competitive process, fiber laser with high beam quality is expected to produce much less thermal damage such as striation, dross, heat affected zone (HAZ), and recast layer. To understand the process capability of fiber laser cutting of Nitinol alloy, a design-of-experiment based laser cutting experiment was performed. The kerf geometry, roughness, topography, microstructure, and hardness were studied to better understand the nature of the HAZ and recast layer in fiber laser cutting. Moreover, effect size analysis was conducted to investigate the relationship between surface integrity and process parameters.

  12. Statistical characteristics of surface integrity by fiber laser cutting of Nitinol vascular stents

    Energy Technology Data Exchange (ETDEWEB)

    Fu, C.H., E-mail: cfu5@crimson.ua.edu [Dept of Mechanical Engineering, The University of Alabama, Tuscaloosa, AL 35487 (United States); Liu, J.F. [Dept of Mechanical Engineering, The University of Alabama, Tuscaloosa, AL 35487 (United States); Guo, Andrew [Dept of Mechanical Engineering, The University of Alabama, Tuscaloosa, AL 35487 (United States); College of Arts and Science, Vanderbilt University, Nashville, TN 37235 (United States)

    2015-10-30

    Graphical abstract: - Highlights: • Precision kerf with tight tolerance of Nitinol stents can be cut by fiber laser. • No HAZ in the subsurface was detected due to large grain size. • Recast layer has lower hardness than the bulk. • Laser cutting speed has a higher influence on surface integrity than laser power. - Abstract: Nitinol alloys have been widely used in manufacturing of vascular stents due to the outstanding properties such as superelasticity, shape memory, and superior biocompatibility. Laser cutting is the dominant process for manufacturing Nitinol stents. Conventional laser cutting usually produces unsatisfactory surface integrity which has a significant detrimental impact on stent performance. Emerging as a competitive process, fiber laser with high beam quality is expected to produce much less thermal damage such as striation, dross, heat affected zone (HAZ), and recast layer. To understand the process capability of fiber laser cutting of Nitinol alloy, a design-of-experiment based laser cutting experiment was performed. The kerf geometry, roughness, topography, microstructure, and hardness were studied to better understand the nature of the HAZ and recast layer in fiber laser cutting. Moreover, effect size analysis was conducted to investigate the relationship between surface integrity and process parameters.

  13. Multiscale electrochemical analysis of the corrosion of titanium and nitinol for implant applications

    International Nuclear Information System (INIS)

    Izquierdo, J.; González-Marrero, M.B.; Bozorg, M.; Fernández-Pérez, B.M.; Vasconcelos, H.C.; Santana, J.J.; Souto, R.M.

    2016-01-01

    Highlights: • Direct screening of differences in the surface reactivity of the passive layers formed on pure titanium and nitinol. • Distinct effect of polarization on the passive layers. • Detection of nickel soluble species released from corrosion pits. - Abstract: Surface electrochemical activity of titanium and nitinol biomaterials in naturally aerated Ringer’s physiological solution was investigated using potentiodynamic polarization and scanning electrochemical microscopy (SECM) techniques. SECM was operated in feedback and redox competition modes as a function of potential applied to the substrate. The kinetics of the electron transfer rate on both materials was characterized by mathematical modelling of the Z-approach curves monitored under feedback conditions. The rate constant values greatly depended on the characteristics of the passive layers formed over the metals under potentiostatic control. A more insulating film was found on nitinol when biased at low polarizations, resulting in smaller tip current increments during tip approach to the investigated surface under positive feedback and competition operation modes. However, at higher anodic polarizations, nitinol passive layers experience breakdown, and therefore tip current values reflect the release of metal cations from the biomaterial surface.

  14. USE OF COVERED SELF-EXPANDABLE NITINOL STENT FOR ANASTOMOTIC BILIARY STRUCTURE MANAGEMENT AFTER LIVER TRANSPLANTATION: THE FIRST EXPERIENCE

    Directory of Open Access Journals (Sweden)

    M. N. Kornilov

    2013-01-01

    Full Text Available Aim. The aim of this study focuses on the first experience with self-expandable stents, analysis of its efficacy and safety in the treatment of anastomotic strictures after liver transplantation. Materials and methods. There’re 136 liver transplantations performed from 2004 till 2012. To correct anastomotic strictures we’ve used only the self-expandable coated nitinol stent. We performed stenting in 7 recipient. Result. In 131 liver transplant recipients incidence of biliary strictures has been 5.3%. All of 5 patients have been managed by retrograde or antegrade way. Conclusion. Our first experience demonstrate efficacy and safety of the used tecniques up to 24 months. The analysis of more long-term results is required. 

  15. Synthesis and Characterization of Nano-Hydroxyapatite/mPEG-b-PCL Composite Coating on Nitinol Alloy

    Directory of Open Access Journals (Sweden)

    Mohamadreza Etminanfar

    2017-12-01

    Full Text Available In this study the bioactivity of hydroxyapatite/poly(ε-caprolactone–poly(ethylene glycol bilayer coatings on Nitinol superelastic alloy was investigated. The surface of Nitinol alloy was activated by a thermo-chemical treatment and hydroxyapatite coating was electrodeposited on the alloy, followed by applying the polymer coating. The surface morphology of coatings was studied using FE-SEM and SEM. The data revealed that the hydroxyapatite coating is composed of one-dimensional nano sized flakes and the polymer coating is uniformly covered the sublayer. Also, High resolution TEM studies on the hydroxyapatite samples revealed that each flake contains nano-crystalline grains with a diameter of about 15 nm. The hydroxyapatite monolayer coating was rapidly covered by calcium phosphate crystals (Ca/P=1.7 after immersion in simulated body fluid confirming the bioactivity of the nanostructured flakes. However, the flakes were weak against applied external forces because of their ultra-fine thickness. Scratch test was applied on hydroxyapatite/polymer coating to evaluate delamination of the coating from substrate. It was shown that, the polymer coating has a great influence on toughening the hydroxyapatite coating. To assess the degradation effect of the polymer layer on hydroxyapatite coating, samples were immersed in phosphate-buffered saline at 37 ᵒC. SEM studies on the samples revealed that the beneath layer of hydroxyapatite appears after 72 h without any visible change in morphology. It seems that, application of a biodegradable polymer film on the nanostructured hydroxyapatite coating is a good way to support the coating during implantation processes

  16. Nitinol for Prosthetic and Orthotic Applications

    Science.gov (United States)

    Henderson, Emma; Buis, Arjan

    2011-07-01

    As global populations age, conditions such as stroke and diabetes require individuals to use rehabilitation technology for many years to come due to chronic musculoskeletal, sensory, and other physical impairments. One in four males currently aged 45 will experience a stroke within 40 years and will often require access to prolonged rehabilitation. In addition, worldwide, one individual loses a limb every 30 s due to the complications of diabetes. As a result, innovative ideas are required to devise more effective prosthetic and orthotic devices to enhance quality of life. While Nitinol has already found much favor within the biomedical industry, one area, which has not yet exploited its unique properties, is in the field of physical rehabilitation, ranging from prosthetic and orthotic devices to assistive technology such as wheelchairs. Improved intervention capabilities based on materials such as Nitinol have the potential to vastly improve patients' quality of life and in the case of orthoses, may even reduce the severity of the condition over time. It is hoped that this study will spark discussion and interest for the materials community in a field which has yet to be fully exploited.

  17. Nitinol stents in the treatment of benign proximal tracheal stenosis or tracheomalacia.

    Science.gov (United States)

    Isa, A Y; Macandie, C; Irvine, B W

    2006-01-01

    Nitinol stents have been used in the treatment of benign tracheal stenosis. A retrospective review of five patients treated at Stobhill Hospital over the last six and a half years is presented. Age at presentation ranged from 17 to 76 years. The minimum follow-up period was 23 months and the maximum was 78 months. All our patients were successfully decannulated, with none requiring recannulation. Four patients developed granulation tissue related to the stent at intervals ranging from three weeks to 41 months post stenting. Topical mitomycin C application has been useful after resection of granulations using the carbon dioxide (CO2) laser. Stent migration occurred in one patient three weeks after insertion. Nitinol stents are easy to insert and effective in the treatment of tracheal stenosis, but can have associated morbidity. Their use should be considered carefully, as insertion should be regarded as permanent. Publications reporting experience and outcome with the use of Nitinol stents in the trachea are reviewed.

  18. Study of the formation process and the characteristics of tantalum layers electrodeposited on Nitinol plates in the 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid

    International Nuclear Information System (INIS)

    Maho, A.; Delhalle, J.; Mekhalif, Z.

    2013-01-01

    Highlights: ► Tantalum electrodeposition on Nitinol plates in the [BMP]Tf 2 N ionic liquid at room temperature. ► Generation of intrinsically nanostructured porous tantalum layers in “soft” cathodic current conditions. ► Important impact of substrate nature, working solution composition and electrodeposition duration. ► Primary assessment of surface corrosion resistance and bioactivity. -- Abstract: Thanks to excellent mechanical and biochemical properties, the nickel–titanium shape memory alloy (Nitinol) constitutes an increasingly praised platform material in dental, cardiovascular and orthopedic biomedical devices. In order to strengthen their protective abilities toward corrosion, to reinforce their biocompatibility and to confer them specific osseointegrative capacities, Nitinol plates are covered with a thin tantalum layer by electrodeposition in the 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid. XPS and SEM/EDX analyses highlight the chemical and morphological characteristics of the deposits: notably, these present an intrinsic dimpled nanometric structuration which is particularly remarkable considering the “soft” experimental conditions and very interesting for fundamental and applied bioactive perspectives. The present study investigates the specific and synergic effects of the Ni occurrence on the surface of the Nitinol substrates, the presence of fluorine species in the working bath, and the electrodeposition duration on the resulting formation process, morphology and chemical composition of the tantalum coating. Finally, samples are submitted to electrochemical characterizations and in vitro hydroxyapatite growth tests for a primary assessment of their corrosion resistance and osseoinductive features

  19. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  20. Branded prescription drug fee. Final regulations, temporary regulations, and removal of temporary regulations.

    Science.gov (United States)

    2014-07-28

    This document contains final regulations that provide guidance on the annual fee imposed on covered entities engaged in the business of manufacturing or importing branded prescription drugs. This fee was enacted by section 9008 of the Patient Protection and Affordable Care Act, as amended by section 1404 of the Health Care and Education Reconciliation Act of 2010. This document also withdraws the Branded Prescription Drug Fee temporary regulations and contains new temporary regulations regarding the definition of controlled group that apply beginning on January 1, 2015. The final regulations and the new temporary regulations affect persons engaged in the business of manufacturing or importing certain branded prescription drugs. The text of the temporary regulations in this document also serves as the text of proposed regulations set forth in a notice of proposed rulemaking (REG-123286-14) on this subject in the Proposed Rules section in this issue of the Federal Register.

  1. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    Science.gov (United States)

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  2. High-resolution 3D X-ray imaging of intracranial nitinol stents

    International Nuclear Information System (INIS)

    Snoeren, Rudolph M.; With, Peter H.N. de; Soederman, Michael; Kroon, Johannes N.; Roijers, Ruben B.; Babic, Drazenko

    2012-01-01

    To assess an optimized 3D imaging protocol for intracranial nitinol stents in 3D C-arm flat detector imaging. For this purpose, an image quality simulation and an in vitro study was carried out. Nitinol stents of various brands were placed inside an anthropomorphic head phantom, using iodine contrast. Experiments with objects were preceded by image quality and dose simulations. We varied X-ray imaging parameters in a commercially interventional X-ray system to set 3D image quality in the contrast-noise-sharpness space. Beam quality was varied to evaluate contrast of the stents while keeping absorbed dose below recommended values. Two detector formats were used, paired with an appropriate pixel size and X-ray focus size. Zoomed reconstructions were carried out and snapshot images acquired. High contrast spatial resolution was assessed with a CT phantom. We found an optimal protocol for imaging intracranial nitinol stents. Contrast resolution was optimized for nickel-titanium-containing stents. A high spatial resolution larger than 2.1 lp/mm allows struts to be visualized. We obtained images of stents of various brands and a representative set of images is shown. Independent of the make, struts can be imaged with virtually continuous strokes. Measured absorbed doses are shown to be lower than 50 mGy Computed Tomography Dose Index (CTDI). By balancing the modulation transfer of the imaging components and tuning the high-contrast imaging capabilities, we have shown that thin nitinol stent wires can be reconstructed with high contrast-to-noise ratio and good detail, while keeping radiation doses within recommended values. Experimental results compare well with imaging simulations. (orig.)

  3. Hardness and Microstructure of Binary and Ternary Nitinol Compounds

    Science.gov (United States)

    Stanford, Malcolm K.

    2016-01-01

    The hardness and microstructure of twenty-six binary and ternary Nitinol (nickel titanium, nickel titanium hafnium, nickel titanium zirconium and nickel titanium tantalum) compounds were studied. A small (50g) ingot of each compound was produced by vacuum arc remelting. Each ingot was homogenized in vacuum for 48 hr followed by furnace cooling. Specimens from the ingots were then heat treated at 800, 900, 1000 or 1100 degree C for 2 hr followed by water quenching. The hardness and microstructure of each specimen was compared to the baseline material (55-Nitinol, 55 at.% nickel - 45 at.% titanium, after heat treatment at 900 degC). The results show that eleven of the studied compounds had higher hardness values than the baseline material. Moreover, twelve of the studied compounds had measured hardness values greater 600HV at heat treatments from 800 to 900 degree C.

  4. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  5. Effect of Applied Potential on Fatigue Life of Electropolished Nitinol Wires

    Science.gov (United States)

    Sivan, Shiril; Di Prima, Matthew; Weaver, Jason D.

    2017-09-01

    Nitinol is used as a metallic biomaterial in medical devices due to its shape memory and pseudoelastic properties. The clinical performance of nitinol depends on factors which include the surface finish, the local environment, and the mechanical loads to which the device is subjected. Preclinical evaluations of device durability are performed with fatigue tests while electrochemical characterization methods such as ASTM F2129 are employed to evaluate corrosion susceptibility by determining the rest potential and breakdown potential. However, it is well established that the rest potential of a metal surface can vary with the local environment. Very little is known regarding the influence of voltage on fatigue life of nitinol. In this study, we developed a fatigue testing method in which an electrochemical system was integrated with a rotary bend wire fatigue tester. Samples were fatigued at various strain levels at electropotentials anodic and cathodic to the rest potential to determine if it could influence fatigue life. Wires at potentials negative to the rest potential had a significantly higher number of cycles to fracture than wires held at potentials above the breakdown potential. For wires for which no potential was applied, they had fatigue life similar to wires at negative potentials.

  6. Drying firewood in a temporary solar kiln: a case study.

    Science.gov (United States)

    George R. Sampson; Anthony F. Gasbarro

    1986-01-01

    A pilot study was undertaken to determine drying rates for small diameter, unsplit paper birch firewood that was dried: (1) in a conventional top-covered pile; (2) in a simple, temporary solar kiln; and (3) in tree length. Drying rates were the same for firewood piles whether they were in the temporary solar kilns or only covered on top to keep rain or snow from...

  7. Monitorizing nitinol alloy surface reactions for biofouling studies

    International Nuclear Information System (INIS)

    Dinu, C.Z.; Dinca, V.C.; Soare, S.; Moldovan, A.; Smarandache, D.; Scarisoareanu, N.; Barbalat, A.; Birjega, R.; Dinescu, M.; DiStefano, V. Ferrari

    2007-01-01

    Growth and deposition of unwanted bacteria on implant metal alloys affect their use as biomedical samples. Monitoring any bacterial biofilm accumulation will provide early countermeasures. For a reliable antifouling strategy we prepared nitinol (NiTi) thin films on Ti-derived substrates by using a pulsed laser deposition (PLD) method. As the microstructure of Ti-alloy is dictated by the tensile strength, fatigue and the fracture toughness we tested the use of hydrogen as an alloying element. X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM) investigated the crystalline structure, chemical composition and respectively the surface morphology of the nitinol hydrogen and hydrogen-free samples. Moreover, the alloys were integrated and tested using a cellular metric and their responses were systematic evaluated and quantified. Our attractive approach is meant to select the suitable components for an effective and trustworthy anti-fouling strategy. A greater understanding of such processes should lead to novel and effective control methods that would improve in the future implant stability and capabilities

  8. Synthesis and Characterization of Nano-Hydroxyapatite/mPEG-b-PCL Composite Coating on Nitinol Alloy

    OpenAIRE

    Mohamadreza Etminanfar; Jafar Khalil-Allafi; Kiyumars Jalili

    2017-01-01

    In this study the bioactivity of hydroxyapatite/poly(ε-caprolactone)–poly(ethylene glycol) bilayer coatings on Nitinol superelastic alloy was investigated. The surface of Nitinol alloy was activated by a thermo-chemical treatment and hydroxyapatite coating was electrodeposited on the alloy, followed by applying the polymer coating. The surface morphology of coatings was studied using FE-SEM and SEM. The data revealed that the hydroxyapatite coating is composed of one-dimensional nano sized fl...

  9. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  10. Evaluation of the 4-French Pulsar-18 Self-expanding Nitinol Stent in Long Femoropopliteal Lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Hailer, Birgit; Kaeunicke, Matthias; Stahlhoff, Wilhelm-Friedrich; Boese, Dirk; Breuckmann, Frank

    2014-01-01

    To evaluate the patency and the freedom of target lesion revascularization of the 4-French Pulsar-18 self-expandable (SE) nitinol stent for the treatment of long femoropopliteal occlusive disease in a two-center, prospective, all-comers registry with a follow-up period of 12 months. This registry enrolled 36 patients with symptomatic femoropopliteal long lesions for recanalization and implantation of the 4-French Pulsar-18 SE nitinol stent. Routine follow-up examination including duplex ultrasound was performed after 6 and 12 months. Primary patency was defined as no binary restenosis on duplex ultrasound (Peak systolic velocitiy ration (PSVR) Pulsar-18 SE nitinol stent for endovascular intervention of femoropopliteal disease with a mean lesion length of 182.3 ± 51.8 mm showed promising primary patency and fTLR rates after 6 and 12 months. Diabetes and renal insufficiency had no negative impact on the patency rate.

  11. Usefulness of a balloon-expandable, covered stent for the transjugular intrahepatic portosystemic shunt

    Directory of Open Access Journals (Sweden)

    Rössle M

    2018-01-01

    Full Text Available The availability of polytetrafluoroethylene (PTFE covered, self-expandable nitinol stents in 2001 considerably improved the patency, response rates and survival of the transjugular intrahepatic portosystemic shunt (TIPS. Side effects of portosystemic shunting such as hepatic encephalopathy (HE and worsening of hepatic function, however, remained a problem. To reduce HE, underdilatation of nitinol stents has been practiced for many years. However, as shown recently, underdilatation was a flop since, due to their intrinsic memory, nitinol stents always expanded to reach their nominal diameter of 8 or 10 mm. To overcome this problem and to be able to perform permanent shunts with a smaller diameter of < 8 mm, we studied the usefulness of a balloon-expandable, covered, metallic stent which allowed adjustment to any diameter between 5 and 12 mm. Methods: 30 patients with cirrhosis and symptomatic portal hypertension were included. The mean Child-Pugh score was 8 ± 2.17 patients had refractory ascites, 9 patients variceal bleeding and four patients other indications for the TIPS. Results: The TIPS was successfully implanted in all patients within 69.6 ± 21.8 min. The shunt reduced the portosystemic pressure gradient by 57.5 ± 14.2% with a mean stent diameter of 7.4 ± 1.0 mm (5 -10.3 mm. During a mean follow-up of 330 ± 249 days, shunt revision was necessary in 5 patients (17%, four of them had insufficient response and received stent dilatation and one patient had stent misplacement requiring a parallel shunt. Three patients (10% developed HE. Conclusions: The covered, balloon-expandable stent could be placed accurately and allowed creation of adapted shunts with smaller diameters as usual. This resulted in a comparatively low rate of HE.

  12. Esophageal leiomyoma in a dog causing esophageal distension and treated by transcardial placement of a self-expanding, covered, nitinol esophageal stent.

    Science.gov (United States)

    Robin, Elisabeth M; Pey, Pascaline B; de Fornel-Thibaud, Pauline; Moissonnier, Pierre H M; Freiche, Valérie

    2018-02-01

    CASE DESCRIPTION A 10-year-old spayed female Rottweiler was referred for evaluation because of a 2-month history of regurgitation and weight loss, despite no apparent change in appetite. The dog had received antiemetic and antacid treatment, without improvement. CLINICAL FINDINGS Physical examination revealed a low body condition score (2/5), but other findings were unremarkable. Diffuse, global esophageal dilatation was noted on plain thoracic radiographs, and normal motility was confirmed through videofluoroscopic evaluation of swallowing. Transhepatic ultrasonographic and CT examination revealed a circumferential, intraparietal lesion in the distal portion of the esophagus causing distal esophageal or cardial subobstruction and no metastases. Incisional biopsy of the lesion was performed, and findings of histologic examination supported a diagnosis of esophageal leiomyoma. TREATMENT AND OUTCOME In view of numerous possible complications associated with esophageal surgery, the decision was made to palliatively treat the dog by transcardial placement of a self-expanding, covered, nitinol esophageal stent under endoscopic guidance. Two weeks after stent placement, radiography revealed complete migration of the stent into the gastric lumen. Gastrotomy was performed, and the stent was replaced and fixed in place. Twenty-four months after initial stent placement, the dog had a healthy body condition and remained free of previous clinical signs. CLINICAL RELEVANCE Diffuse benign muscular neoplasia should be considered as a differential diagnosis for acquired esophageal dilatation in adult and elderly dogs. In the dog of this report, transcardial stent placement resulted in resolution of the clinical signs, with no apparent adverse effect on digestive function. The described procedure could be beneficial for nonsurgical treatment of benign esophageal tumors in dogs.

  13. Comparison of visibility for four self-expanding nitinol bare stents in vitro

    International Nuclear Information System (INIS)

    Wiesinger, Benjamin; Stutz, Alexander; Schmehl, Joerg; Groezinger, Gerd; Claussen, Claus Detlef; Wiskirchen, Jakub

    2012-01-01

    Background Sufficient radiopacity of stents is a prerequisite for safe interventions and minimization of the radiation dose for the patient and the interventionist. Modern nitinol stents are considered less radiopaque compared to formerly used stents. Purpose To evaluate the objective detection rate (ODR) and the subjective radiopacity score (SRS) of four self-expanding nitinol stents with their markers on a phantom human pelvis. Material and Methods We evaluated the ODR (as a percentage of correctly identified stents) and the SRS (on a scale from 0 = not visible to 4 = excellent visibility) for four self-expanding nitinol stents (SinusSuperflex, SMART, Luminexx, Zilver) with 8 mm diameter and 40 mm length. Stents were placed on a phantom human pelvis and images of the stents were taken in four different positions (right and left lumbosacral joint and near the right and left limbus acetabuli) using the following modes: spotfilm, pulsed fluoroscopy (4, 7.5, 15, and 30 pulses/min) and at three different digital magnification modes. Dose area products (DAPs) were assessed. Results ODR and SRS, respectively, were significantly increased for the SMART stent compared to all other tested stents (P < 0.05): SMART 93.53% and 2.43, SinusSuperflex 90.81% and 2.21, Luminexx 90.39% and 2.20, and Zilver 89.28% and 2.21. ODR was significantly reduced in position 3 where the bone overlap was more pronounced for all stents (detection rates 77.14-79.56%). An increase in magnification significantly improved the ODR and SRS for all stents (70.33-99.25% and 1.07-3.28, respectively, P < 0.05). Increased pulsing frequency did not improve the ODR of the various stents but did increase the DAP. Conclusion The SMART stent had the best overall performance. In the presence of bone overlap, all self-expanding nitinol stents had poor results. Increased pulsing frequency did not improve ODR or SRS but did increase the DAP. Use of digital magnification modes had no effect on DAP increasing ODR

  14. Transcatheter aortic value implantation with self-expandable nitinol valved stent: an experimental study in sheep

    International Nuclear Information System (INIS)

    Jiang Haibin; Huang Xinmiao; Bai Yuan

    2011-01-01

    Objective: to determine the feasibility and safety of transcatheter aortic valve implantation with domestic self-expandable nitinol valved stent in experimental sheep. Methods: A fresh pig pericardium was cross-linked with a 0.6% glutaraldehyde solution for 36 hours and then sutured on a nitinol self-expandable stent. Ten healthy sheep of (46.00±2.60) kg body weight were chosen for the study. Under general anesthesia, the device was delivered through catheter into the native aortic valve of the sheep via the femoral artery or abdominal aorta. The animals were followed up for three months. Results: Six devices were successfully delivered at the desired position in six sheep with no occurrence of complications. Angiographic and hemodynamic studies confirmed that the stents were fixed at correct position with competent valve function immediately and 90 days after the procedure. Technical failure or fatal complications occurred in the remaining four sheep. Conclusion: Implantation of a domestic nitinol self-expandable stent at the aortic valve position through a transcatheter approach is feasible in experimental sheep. (authors)

  15. Treatment of Benign Tracheal Stenosis Utilizing Self-Expanding Nitinol Stents

    International Nuclear Information System (INIS)

    Sesterhenn, Andreas M.; Wagner, Hans-Joachim; Alfke, Heiko; Werner, Jochen A.; Lippert, Burkard M.

    2004-01-01

    We assessed the results of self-expanding metallic stent insertion into benign proximal tracheal stenosis in patients not appropriate or unfit for surgical repair. Proximal benign tracheal stenoses had occurred in 11 patients (7 men, 4 women, mean age 68.8 years) after long-time intubation (n = 6), tracheostomy (n = 4), or chondropathia (n = 1). Fourteen self-expanding nitinol stents were placed in the patients under general anesthesia with endoscopical and fluoroscopical guidance. Stent insertion was successful in all cases and led to immediate relief of the morphological and functional airway obstruction. No immediate complications were noted. During the mean follow-up period of 67.5 weeks we observed one recurrent dyspnea 3 months after implantation and granuloma formation at the stent insertion site in another patient. Both complications were successfully treated with additional stent insertion in one case and laser resection of granulomas in the other. Self-expanding nitinol stents should be considered for the treatment of benign proximal tracheal obstruction in selected patients for whom surgical repair is contraindicated

  16. Designing and simulating a nitinol-based micro ejector

    Directory of Open Access Journals (Sweden)

    Yesid Mora Sierra

    2012-01-01

    Full Text Available This paper describes pico-droplet ejector design and simulation. The actuation system was based on two interconnected nitinol membranes’ shape memory effect. Ejected volume was 12pL and it operated at 30°C to 64°C. Ejecting excitation voltage was 12V and the ejecting energy required by actuator operation was 26µJ per drop. These pico-liter ejectors could have applications in making, lubricating and cooling integrated circuits.

  17. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Rajan, Dheeraj K.; Saluja, Jasdeep S.

    2007-01-01

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm. The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  18. Temporary/portable nuclear fallout shelter

    Energy Technology Data Exchange (ETDEWEB)

    Hampel, V E

    1991-01-15

    The design and invention of a temporary/portable fallout shelter has been described in context of schematic and representative embodiments. Tent structures are described which include disposable, exterior, semi-transparent plastic and/or fabric shield membranes covering a tent composed of stretched, tightly woven, rip-resistant fabric panels supported by tensile rods/wands. 16 figs.

  19. Thermophysical Properties of 60-NITINOL for Mechanical Component Applications

    Science.gov (United States)

    Stanford, Malcolm K.

    2012-01-01

    The linear thermal expansion coefficient, specific heat capacity, electrical resistivity and thermal conductivity of 60- NITINOL were studied over a range of temperatures representing the operating environment of an oil-lubricated bearing. The behavior of this material appears to follow wellestablished theories applicable to either metal alloys, in general, or to intermetallic compounds, more specifically and the measured data were found to be comparable to those for conventional bearing alloys.

  20. The impact of organochlorines cycling in the cryosphere on global distributions and fate – 2. Land ice and temporary snow cover

    International Nuclear Information System (INIS)

    Hofmann, Lorenz; Stemmler, Irene; Lammel, Gerhard

    2012-01-01

    Global fate and transport of γ-HCH and DDT was studied using a global multicompartment chemistry-transport model, MPI-MCTM, with and without inclusion of land ice (in Antarctica and Greenland) or snow cover (dynamic). MPI-MCTM is based on coupled ocean and atmosphere general circulation models. After a decade of simulation 4.2% γ-HCH and 2.3% DDT are stored in land ice and snow. Neglection of land ice and snow in modelling would underestimate the total environmental residence time, τ ov , of γ-HCH and overestimate τ ov for DDT, both on the order of 1% and depending on actual compartmental distribution. Volatilisation of DDT from boreal, seasonally snow covered land is enhanced throughout the year, while volatilisation of γ-HCH is only enhanced during the snow-free season. Including land ice and snow cover in modelling matters in particular for the Arctic, where higher burdens are predicted to be stored. - Highlights: ► Land ice and snow hosts 2–4% of the global environmental burden of γ-HCH and DDT. ► Inclusion of land ice and snow cover matters for global environmental residence time. ► Including of land ice and snow cover matters in particular for the Arctic. - The inclusion of cycling in temporary snow cover and land ice in the model is found relevant for predicted POPs multicompartmental distribution and fate in the Arctic and on the global scale.

  1. Hierarchical periodic micro/nano-structures on nitinol and their influence on oriented endothelialization and anti-thrombosis

    International Nuclear Information System (INIS)

    Nozaki, Kosuke; Shinonaga, Togo; Ebe, Noriko; Horiuchi, Naohiro; Nakamura, Miho; Tsutsumi, Yusuke; Hanawa, Takao; Tsukamoto, Masahiro; Yamashita, Kimihiro; Nagai, Akiko

    2015-01-01

    The applications of hierarchical micro/nano-structures, which possess properties of two-scale roughness, have been studied in various fields. In this study, hierarchical periodic micro/nano-structures were fabricated on nitinol, an equiatomic Ni–Ti alloy, using a femtosecond laser for the surface modification of intravascular stents. By controlling the laser fluence, two types of surfaces were developed: periodic nano- and micro/nano-structures. Evaluation of water contact angles indicated that the nano-surface was hydrophilic and the micro/nano-surface was hydrophobic. Endothelial cells aligned along the nano-structures on both surfaces, whereas platelets failed to adhere to the micro/nano-surface. Decorrelation between the responses of the two cell types and the results of water contact angle analysis were a result of the pinning effect. This is the first study to show the applicability of hierarchical periodic micro/nano-structures for surface modification of nitinol. - Highlights: • Hierarchical micro/nano-structures were created on nitinol using a femtosecond laser. • The nano-surface was hydrophilic and the micro/nano-surface was hydrophobic. • Endothelial cells aligned along the nano-structures • Platelets failed to adhere to the micro/nano-surface

  2. Hierarchical periodic micro/nano-structures on nitinol and their influence on oriented endothelialization and anti-thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Nozaki, Kosuke [Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062 (Japan); Shinonaga, Togo [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Ebe, Noriko; Horiuchi, Naohiro; Nakamura, Miho; Tsutsumi, Yusuke; Hanawa, Takao [Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062 (Japan); Tsukamoto, Masahiro [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Yamashita, Kimihiro [Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062 (Japan); Nagai, Akiko, E-mail: nag-bcr@tmd.ac.jp [Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda, Tokyo 101-0062 (Japan)

    2015-12-01

    The applications of hierarchical micro/nano-structures, which possess properties of two-scale roughness, have been studied in various fields. In this study, hierarchical periodic micro/nano-structures were fabricated on nitinol, an equiatomic Ni–Ti alloy, using a femtosecond laser for the surface modification of intravascular stents. By controlling the laser fluence, two types of surfaces were developed: periodic nano- and micro/nano-structures. Evaluation of water contact angles indicated that the nano-surface was hydrophilic and the micro/nano-surface was hydrophobic. Endothelial cells aligned along the nano-structures on both surfaces, whereas platelets failed to adhere to the micro/nano-surface. Decorrelation between the responses of the two cell types and the results of water contact angle analysis were a result of the pinning effect. This is the first study to show the applicability of hierarchical periodic micro/nano-structures for surface modification of nitinol. - Highlights: • Hierarchical micro/nano-structures were created on nitinol using a femtosecond laser. • The nano-surface was hydrophilic and the micro/nano-surface was hydrophobic. • Endothelial cells aligned along the nano-structures • Platelets failed to adhere to the micro/nano-surface.

  3. Effects of a temporary HDPE cover on landfill gas emissions: multiyear evaluation with the static chamber approach at an Italian landfill.

    Science.gov (United States)

    Capaccioni, Bruno; Caramiello, Cristina; Tatàno, Fabio; Viscione, Alessandro

    2011-05-01

    According to the European Landfill Directive 1999/31/EC and the related Italian Legislation ("D. Lgs. No. 36/2003"), monitoring and control procedures of landfill gas emissions, migration and external dispersions are clearly requested. These procedures could be particularly interesting in the operational circumstance of implementing a temporary cover, as for instance permitted by the Italian legislation over worked-out landfill sections, awaiting the evaluation of expected waste settlements. A possible quantitative approach for field measurement and consequential evaluation of landfill CO(2), CH(4) emission rates in pairs consists of the static, non-stationary accumulation chamber technique. At the Italian level, a significant and recent situation of periodical landfill gas emission monitoring is represented by the sanitary landfill for non-hazardous waste of the "Fano" town district, where monitoring campaigns with the static chamber have been annually conducted during the last 5 years (2005-2009). For the entire multiyear monitoring period, the resulting CO(2), CH(4) emission rates varied on the whole up to about 13,100g CO(2) m(-2)d(-1) and 3800 g CH(4) m(-2)d(-1), respectively. The elaboration of these landfill gas emission data collected at the "Fano" case-study site during the monitoring campaigns, presented and discussed in the paper, gives rise to a certain scientific evidence of the possible negative effects derivable from the implementation of a temporary HDPE cover over a worked-out landfill section, notably: the lateral migration and concentration of landfill gas emissions through adjacent, active landfill sections when hydraulically connected; and consequently, the increase of landfill gas flux velocities throughout the reduced overall soil cover surface, giving rise to a flowing through of CH(4) emissions without a significant oxidation. Thus, these circumstances are expected to cause a certain increase of the overall GHG emissions from the given

  4. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-05-15

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} 10.82% (type A) and 13.80 {+-} 6.94% (type B) ({rho} < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 {+-} 10.84% (type A). 87.58 {+-} 7.36% (type B) ({rho} = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern.

  5. The New Nitinol Conformable Self-Expandable Metal Stents for Malignant Colonic Obstruction: A Pilot Experience as Bridge to Surgery Treatment

    Directory of Open Access Journals (Sweden)

    Roberto Di Mitri

    2014-01-01

    Full Text Available Introduction. Self-expandable metal stents (SEMS are a nonsurgical option for treatment of malignant colorectal obstruction also as a bridge to surgery approach. The new nitinol conformable stent has improved clinical outcomes in these kinds of patients. We report a pilot experience with nitinol conformable SEMS placement as bridge to surgery treatment in patients with colorectal obstruction. Materials and Methods. Between April and August 2012, we collected data on colonic nitinol conformable SEMS placement in a cohort of consecutive symptomatic patients, with malignant colorectal obstruction, who were treated as a bridge to surgery. Technical success, clinical success, and adverse events were recorded. Results. Ten patients (7 male (70%, with a mean age of 69.2 ± 10.1, were evaluated. The mean length of the stenosis was 3.6 ± 0.6 cm. Five patients (50% were treated on an emergency basis. The median time from stent placement to surgery was 16 days (interquartile range 7–21. Technical and clinical success was achieved in all patients with a significant early improvement of symptoms. No adverse events due to the SEMS placement were observed. Conclusion. This pilot study confirmed the important role of nitinol conformable SEMS as a bridge to surgery option in the treatment of symptomatic malignant colorectal obstruction.

  6. Surface modification and fatigue behavior of nitinol for load bearing implants

    Science.gov (United States)

    Bernard, Sheldon A.

    Musculoskeletal disorders are recognized amongst the most significant human health problems that exist today. Even though considerable research and development has gone towards understanding musculoskeletal disorders, there is still lack of bone replacement materials that are appropriate for restoring lost structures and functions, particularly for load-bearing applications. Many materials on the market today, such as titanium and stainless steel, suffer from significantly higher modulus than natural bone and low bioactivity leading to stress shielding and implant loosening over longer time use. Nitinol (NiTi) is an equiatomic intermetallic compound of nickel and titanium whose unique biomechanical and biological properties contributed to its increasing use as a biomaterial. An innovative method for creating dense and porous net shape NiTi alloy parts has been developed to improve biological properties while maintaining comparable or better mechanical properties than commercial materials that are currently in use. Laser engineered net shaping (LENS(TM)) and surface electrochemistry modification was used to create dense/porous samples and micro textured surfaces on NiTi parts, respectively. Porous implants are known to promote cell adhesion and have a low elastic modulus, a combination that can significantly increase the life of an implant. However, porosity can significantly reduce the fatigue life of an implant, and very little work has been reported on the fatigue behavior of bulk porous metals, specifically on porous nitinol alloy. High-cycle rotating bending and compression-compression fatigue behavior of porous NiTi fabricated using LENS(TM) were studied. In cyclic compression loading, plastic strain increased with increasing porosity and it was evident that maximum strain was achieved during the first 50000 cycles and remained constant throughout the remaining loading. No failures were observed due to loading up to 150% of the yield strength. When subjected

  7. Self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty

    International Nuclear Information System (INIS)

    Tepe, Gunnar; Heller, Stephan; Wiskirchen, Jakub; Fischmann, Arne; Claussen, Claus D.; Zeller, Thomas; Coerper, Stephan; Beckert, Stefan; Balletshofer, Bernd

    2007-01-01

    The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent implantation was feasible in all cases. No complications occurred. After the stent implantation, all primarily unsuccessful interventions could be transformed into successful procedures with no residual stenosis >30% in any case. After 6 ± 2 months, two of the 18 patients died, and 14 of the 16 remaining patients improved clinically. At follow-up, the patency could be assessed in 14 stented arteries. Three stents were occluded, one stent showed some neointimal hyperplasia (50-70% restenosis), the remaining ten stents showed no restenosis (0-30%). The use of self-expanding nitinol stents in tibioperoneal and popliteal arteries is a safe and feasible option for the treatment of unsuccessful PTA. The 6-months patency is high. (orig.)

  8. Carbon fibre and nitinol needles for MRI-guided interventions: First in vitro and in vivo application

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Christoph, E-mail: Christoph.thomas@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Wojtczyk, Hanne [Section of Experimental Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Rempp, Hansjoerg; Clasen, Stephan; Horger, Marius [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Lassberg, Christoph von [Department of Sports Medicine, University of Tuebingen, Silcherstrasse 5, 72076 Tuebingen (Germany); Fritz, Jan [Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, 600 North Wolfe Street, Baltimore, MD 21287 (United States); Claussen, Claus D. [Department of Diagnostic and Interventional Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, 72076 Tuebingen (Germany); Pereira, Philippe L. [Department of Radiology, Minimally Invasive Therapies and Nuclearmedicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078 Heilbronn (Germany)

    2011-09-15

    Objective: To assess the artefact properties of a MR-compatible carbon fibre needle with a nitinol mandrin in vitro and to report first clinical experiences. Materials and methods: In vitro, the carbon fibre/nitinol needle was imaged at different angles against the main magnetic field (1.5 T open bore magnet). A gradient echo MR fluoroscopy sequence (GRE: TR 9.3 ms, TE 3.12 ms, bandwidth 200 Hz/pixel, flip-angle 12{sup o}) and a fast turbo spin echo sequence (FSE: TR 412 ms, TE 9.7 ms, bandwidth 200 Hz/pixel, flip-angle 150{sup o}) were used. Artefact width, needle intensity contrast and needle tip location errors were assessed. In vivo, lumbar periradicular corticosteroid injections and one sclerotherapy were performed with carbon fibre needles (10 procedures) and with titanium alloy needles (2 procedures). The artefact sizes and contrasts were measured. Results: In vitro, artefact diameters of the carbon fibre needle ranged from 3.3 to 4.6 mm, contrasts from 0.11 to 0.52, with larger artefact contrasts and widths with the GRE sequence. Needle tip location errors of -2.1 to -2.8 mm were observed. Decreasing angles to the main field lead to smaller artefacts. In vivo, the carbon fibre/nitinol needle produced smaller artefacts (mean width FSE/GRE: 2.8 mm/4.6 mm) with lower contrast (0.30-0.42) than the titanium alloy needle (mean width FSE/GRE: 4.1 mm/7.5 mm, contrast 0.60-0.73). Conclusions: The carbon fibre/nitinol needle is useful for performing MR-guided interventions at 1.5 T, producing more subtle artefacts than a titanium alloy needle, but with an incomplete depiction and thus inaccurate localization of the needle tip.

  9. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo

    International Nuclear Information System (INIS)

    Zhang, Zhi xiong; Fu, Bu fang; Zhang, De yuan; Zhang, Zhi wei; Cheng, Yan; Sheng, Li yuan; Lai, Chen; Xi, Ting fei

    2013-01-01

    Atrial septal defect (ASD) occlusion devices made of nickel–titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium–nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. - Highlights: ► The nano lamella TiN coating did not change the shape-memory behavior and flexibility of the nitinol occluder. ► Nano lamella TiN coating modifications significantly reduced nickel release from nitinol ASD occluder. ► The new ASD occluder was found to be superior to nitinol ASD occluder with respect to both safety and efficacy

  10. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Zhi xiong, E-mail: Top5460@163.com [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Fu, Bu fang, E-mail: fubnicpbp@163.com [National Institutes for Food and Drug Control, Beijing (China); Zhang, De yuan, E-mail: Deyuanzhangcn@yahoo.com.cn [Lifetech Scientific (Shenzhen) Co., Ltd., Shenzhen (China); Zhang, Zhi wei, E-mail: Zhzhx65@163.com [Guangdong Cardiovascular Institute, Guangzhou (China); Cheng, Yan, E-mail: chengyan@pku.edu.cn [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing (China); Sheng, Li yuan, E-mail: lysheng@yeah.net [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Lai, Chen, E-mail: laichen1110@163.com [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Xi, Ting fei, E-mail: Xitingfie@pku.edu.cn [Research Institute of Peking University in Shenzhen, Shenzhen 518057 (China); Academy for Advanced Interdisciplinary Studies, Peking University, Beijing (China)

    2013-04-01

    Atrial septal defect (ASD) occlusion devices made of nickel–titanium (NiTi) have a major shortcoming in that they release nickel into the body. We modified NiTi occluders using Arc Ion Plating technology. Nano lamellar titanium–nitrogen (TiN) coatings were formed on the surfaces of the occluders. The safety and efficacy of the modified NiTi occluders were evaluated in animal model. The results showed that 38 out of 39 rams (97%) survived at the end of the experiment. Fibrous capsules formed on the surfaces of the devices. Gradual endothelialization took place through the attachment of endothelial progenitor cells from the blood and the migration of endothelial cells from adjacent endocardium. The neo-endocardium formed more quickly in the coated group than in the uncoated group, as indicated by the evaluation of the six month study group. After TiN coating, there was no significant difference in endothelial cell cycle. TiN coating significantly reduced the release of nickel in both in vivo and in vitro indicating an improved biocompatibility of the nitinol ASD occluders. Superior and modified ASD occluders may provide a good choice for people with nickel allergies after sFDA registration, which is expected in one to two years. - Highlights: ► The nano lamella TiN coating did not change the shape-memory behavior and flexibility of the nitinol occluder. ► Nano lamella TiN coating modifications significantly reduced nickel release from nitinol ASD occluder. ► The new ASD occluder was found to be superior to nitinol ASD occluder with respect to both safety and efficacy.

  11. [Self-expanding nitinol stents in proximal tracheal stenosis].

    Science.gov (United States)

    Hafner, B; Mann, W; Heussel, C P; Scherhag, A; Schlegel, J; Kauczor, H U

    2000-03-01

    The use of silicone- or metal stents in stenosis of the distal trachea and the bronchial system is a customary procedure [1-4], for example after tumor invasion or cicatricial stenosis after transplantation. In the proximal part of the trachea, on smaller, short and soft strictures we try to stabilise the trachea by the implantation of rings. Other methods are tracheal plasty or transverse tracheal resectomy [5-7]. In the case of longer or nearer subglottal stenoses the positioning of self-expanding nitinol stents has proven a simple, gentle and well-tolerated alternative procedure even in very serious disorders [1, 8, 9]. These stents can be placed in short narcosis under endoscopic control without great strain on the patient. We placed nitinol-stents in the proximal part of the trachea in eleven cases. In five cases dyspnoea caused by a tracheal collapse improved. In two further cases a tracheal stenosis with massive granulation tissue and cicatricial pull under an inlaid tracheal cannula was removed and the tracheostoma was closed. In four cases a solid, scarred and cartilaginous stenosis in the area of the cricoid and the upper tracheal rings was widened with laser and later on stented. Over an observation time of two years no complications showed safe one case in which a directly postoperative dislocation was repositioned quickly. The patients live without restrictions through the tracheal stenosis or a tracheostoma. In the best possible case epithelialization over the metal meshes develops so that a nearly normal mucus transportation is possible [1, 10-12].

  12. Effect of Slip Time in Forming Neo-Esophageal Stenosis After Replacement of a Thoracic Esophagus With Nitinol Artificial Esophagus.

    Science.gov (United States)

    Liang, Xian-Liang; Liang, Jian-Hui

    2015-07-01

    Attempts have been made to investigate the effect of slip time of nitinol artificial esophagus for forming neo-esophageal stenosis after replacement of a thoracic esophagus with nitinol artificial esophagus in 20 experimental pigs. The pigs whose slip time was less than 90 days postoperatively had severe dysphagia (Bown's III) immediately after they were fed, and the dysphagia aggravated gradually later on (Bown's III-IV). The pigs whose slip time was more than 90 days postoperatively had mild/moderate dysphagia (Bown's I-II) immediately after they were fed, and the dysphagia relieved gradually later on (Bown's II-I-0). The ratios between the diameter of neo-esophagus in different slip time and normal esophagus were 25% (at 2 months postoperatively), 58% (at 4 months postoperatively), and 93% (at 6 months postoperatively), respectively. The relationship between nitinol artificial esophagus slip time and neo-esophageal stenosis showed a positive correlation. After replacement of a thoracic esophagus with nitinol artificial esophagus, the artificial esophageal slip time not only affected the original diameter of the neo-esophagus immediately, but also affected the neo-esophageal scar stricture forming process later on. The narrowing of neo-esophagus is caused by overgrowth of scar tissue. But there is the positive correlation between artificial esophagus slip time and neo-esophageal stenosis, so this can be a way of overcoming neo-esophageal stenosis by delaying slip time of artificial esophagus. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. The influence of stent design on neointimal hyperplasia of an aortic stent covering the visceral arterial ostia: an experimental study in dogs using a self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Yin, Yong Hu; Chung, Jin Wook; Choi, Seung Hong; Kim, Kwang Gi; Kim, Hyo Cheol; So, Young Ho; Jae, Hwan Jun; Lee, Whal; Park, Jae Hyung

    2008-01-01

    To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 ± 10.82% (type A) and 13.80 ± 6.94% (type B) (ρ < 0.0001)]. Furthermore, the area ratios of the neointimal hyperplasia per area of stent-wire in the given area were 138.38 ± 10.84% (type A). 87.58 ± 7.36% (type B) (ρ = 0.0002). In conclusion the interlacing pattern vs. the crossing pattern showed a higher level of neointimal formation than the crossing pattern

  14. Temporary loop ileostomy: prospective study of indications and complication

    International Nuclear Information System (INIS)

    Rajput, A.; Samad, A.; Khanzada, T.W.

    2007-01-01

    To asses the indications and complications of temporary loop ileostomy. This was a prospective cohort study conducted at Isra University Hospital, Hyderabad, Pakistan between February 2003 and August 2006. All patients who had temporary loop ileostomy during that period were included in this study. The indications and various postoperative complications were noted during postoperative hospital stay and subsequently during follow up till stoma were closed. Fifty six patients fulfilled the selection criteria during the study period. Typhoid (enteric) perforation was the most common indication of loop ileostomy accounting for about two thirds of all cases. Other indications were iatrogenic, covering ileostomy for rectal cancers, following resection anastomosis, tuberculosis, blunt abdominal trauma, anastomosis leak and rectovaginal fistula. Post operative skin excoriation was the most common complication while poor siting, transient edema, retraction and high output were other less common complications. Temporary loop ileostomy is the stoma of choice for temporary faecal diversion as most of its complications are manageable conservatively. (author)

  15. Stress Corrosion Evaluation of Nitinol 60 for the International Space Station Water Recycling System

    Science.gov (United States)

    Torres, P. D.

    2016-01-01

    A stress corrosion cracking (SCC) evaluation of Nitinol 60 was performed because this alloy is considered a candidate bearing material for the Environmental Control and Life Support System (ECLSS), specifically in the Urine Processing Assembly of the International Space Station. An SCC evaluation that preceded this one during the 2013-2014 timeframe included various alloys: Inconel 625, Hastelloy C-276, titanium (Ti) commercially pure (CP), Ti 6Al-4V, extra-low interstitial (ELI) Ti 6Al-4V, and Cronidur 30. In that evaluation, most specimens were exposed for a year. The results of that evaluation were published in NASA/TM-2015-218206, entitled "Stress Corrosion Evaluation of Various Metallic Materials for the International Space Station Water Recycling System,"1 available at the NASA Scientific and Technical Information program web page: http://www.sti.nasa.gov. Nitinol 60 was added to the test program in 2014.

  16. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-01-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-termmorbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD. PMID:29470746

  17. Nitinol Stents in the Femoropopliteal Artery: A Mechanical Perspective on Material, Design, and Performance.

    Science.gov (United States)

    Maleckis, Kaspars; Anttila, Eric; Aylward, Paul; Poulson, William; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2018-05-01

    Endovascular stenting has matured into a commonly used treatment for peripheral arterial disease (PAD) due to its minimally invasive nature and associated reductions in short-term morbidity and mortality. The mechanical properties of the superelastic Nitinol alloy have played a major role in the explosion of peripheral artery stenting, with modern stents demonstrating reasonable resilience and durability. Yet in the superficial femoral and popliteal arteries, even the newest generation Nitinol stents continue to demonstrate clinical outcomes that leave significant room for improvement. Restenosis and progression of native arterial disease often lead to recurrence of symptoms and reinterventions that increase morbidity and health care expenditures. One of the main factors thought to be associated with stent failure in the femoropopliteal artery (FPA) is the unique and highly dynamic mechanical environment of the lower limb. Clinical and experimental data demonstrate that the FPA undergoes significant deformations with limb flexion. It is hypothesized that the inability of many existing stent designs to conform to these deformations likely plays a role in reconstruction failure, as repetitive movements of the leg and thigh combine with mechanical mismatch between the artery and the stent and result in mechanical damage to both the artery and the stent. In this review we will identify challenges and provide a mechanical perspective of FPA stenting, and then discuss current research directions with promise to provide a better understanding of Nitinol, specific features of stent design, and improved characterization of the biomechanical environment of the FPA to facilitate development of better stents for patients with PAD.

  18. Influence of Nitinol wire surface treatment on oxide thickness and composition and its subsequent effect on corrosion resistance and nickel ion release.

    Science.gov (United States)

    Clarke, B; Carroll, W; Rochev, Y; Hynes, M; Bradley, D; Plumley, D

    2006-10-01

    Medical implants and devices are now used successfully in surgical procedures on a daily basis. Alloys of nickel and titanium, and in particular Nitinol are of special interest in the medical device industry, because of their shape memory and superelastic properties. The corrosion behavior of nitinol in the body is also of critical importance because of the known toxicological effects of nickel. The stability of a NiTi alloy in the physiological environment is dependant primarily on the properties of the mostly TiO(2) oxide layer that is present on the surface. For the present study, a range of nitinol wires have been prepared using different drawing processes and a range of surface preparation procedures. It is clear from the results obtained that the wire samples with very thick oxides also contain a high nickel content in the oxide layer. The untreated samples with the thicker oxides show the lowest pitting potential values and greater nickel release in both long and short-term experiments. It was also found that after long-term immersion tests breakdown potentials increased for samples that exhibited lower values initially. From these results it would appear that surface treatment is essential for the optimum bioperformance of nitinol. (c) 2006 Wiley Periodicals, Inc

  19. Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries

    International Nuclear Information System (INIS)

    Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate; Li Ruizong

    2000-01-01

    Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. A neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter

  20. A novel method of creation of a fenestration in nitinol occluder devices used in closure of hypertensive patent arterial ducts

    Directory of Open Access Journals (Sweden)

    Anil Kumar Singhi

    2016-01-01

    Full Text Available Test occlusion with a balloon is done to predict operability of large hypertensive patent ductus arteriosus (PDA. If the fall in the pulmonary artery pressures is inadequate, a complete closure is not desired. To create a predictable premeasured fenestration in a nitinol occluder device used for closing hypertensive PDA. A large nitinol occluder device was punctured with an 18G needle to advance a 0.035½ stiff guide wire through the occluder before loading it into the delivery system. The occluder with the guidewire was then deployed across the PDA. A coronary guide catheter was later threaded through the guidewire into the fabric of the device, which was still held by the delivery cable. A coronary stent was deployed across the fenestration in the occluder to keep it patent. An 8-year-old boy with Down syndrome and hypertensive PDA was hemodynamically assessed. Even though there was a fall in the pulmonary vascular resistance index and pressures on test occlusion, the pulmonary artery pressures were labile with fluctuations. A customized fenestration was made in a 16 mm muscular ventricular septal defect occluder (MVSO with a 4.5 mm bare-metal coronary stent. The pulmonary artery pressures remained at half of the aortic pressures after the procedure. This fenestration model precisely and predictably fenestrated a large occluder device used to close a hypertensive large PDA. Long-term patency of these fenestrations has to be assessed on the follow-up, and may be improved through larger fenestrations, systemic anticoagulation and use of covered stents.

  1. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  2. Treatment of Complex Fistula-in-Ano With a Nitinol Proctology Clip

    DEFF Research Database (Denmark)

    Nordholm-Carstensen, Andreas; Krarup, Peter-Martin; Hagen, Kikke

    2017-01-01

    BACKGROUND: The treatment of complex anocutaneous fistulas remains a major therapeutic challenge balancing the risk of incontinence against the chance of permanent closure. OBJECTIVE: The purpose of this study was to investigate the efficacy of a nitinol proctology clip for closure of complex ano...... with those of other noninvasive, sphincter-sparing techniques for high-complex anocutaneous fistulas, with no risk of incontinence. Predictive parameters for fistula healing using this technique remain uncertain. See Video Abstract at http://links.lww.com/DCR/A347....

  3. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    International Nuclear Information System (INIS)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup

    1995-01-01

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction

  4. Dysphagia with malignant stricture of esophagogastric junction: treatment with self-expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyeong; Yoon, Yup [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-02-15

    To evaluate the effectiveness, patency and safety of a self-expandable nitinol stent for palliative treatment of malignant stricture of gastroesophageal junction. An esophageal stent was inserted in five consecutive patients with malignant stricture of esophagogastric junction. Histologically, four cases were adenocarcinoma, and one was squamous cell carcinoma. The location and severity of stricture were evaluated with gastrografin just before stent insertion. In one patient with past subtotal gastrectomy, esophagography revealed fistulous fract at stricture site. No technical failure or procedural complications occurred, and improvement of dysphagia was noted in all patients soon after stent insertion. On follow up esophagograms performed 3 to 7 days after stent insertion, all stents were completely expanded and unchanged in positions. In one patient with fistulous connection at stricture site, esophagogram immediately after the procedure revealed complete occlusion of the fistula. Three patients died within 4, 7 and 8 consecutive months after stent insertion. Two patients are alive maintaining adequate body weight and passing most diet. Seft-expandable nitinol stent with it's good longitudinal flexibility and efficient radial force was effective in the palliative treatment of dysphagia in patient with malignant stricture at esophagogastric junction.

  5. THE USE OF NITINOL RODS IN SURGICAL TREATMENT OF DEGENERATIVE SCOLIOSIS. 2.5-YEAR FOLLOW-UP

    Directory of Open Access Journals (Sweden)

    Natalia Sergeyevna Morozova

    2016-03-01

    Full Text Available ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases pedicle screws and nitinol rods with a diameter of 5.5 mm were used. Thirty patients underwent fixation at L1-S1 and 40 patients underwent fixation at L1-L5. Spinal fusion was not performed. All patients had radiography, CT and MRI performed. The results were assessed according to the Oswestry scale, SRS 22, SF 36 and VAS. The minimum follow-up period for all patients was 2.5 years. For the control group, consisting of 72 patients, pedicle fixation with titanium rods and interbody fusion in the lumbosacral region were performed. Results: The average level of deformity correction equaled 25° (10° - 38°. The analysis of X-ray and CT-scans revealed a single patient with implant instability, two patients with bone resorption around the screws and one patient with rod fractures. Functional radiography 2.5 years after surgery showed an average mobility of the lumbar spine of 21° (15° - 30°. There were no problems at the adjacent levels. Conclusions: The use of nitinol rods in spinal deformity surgery is promising. This technology is an alternative to rigid fixation. Continued gathering of clinical data and its further evaluation is necessary.

  6. Bleeding after expandable nitinol stent placement in patients with esophageal and upper gastrointestinal obstruction: incidence, management, and predictors.

    Science.gov (United States)

    Oh, Se Jin; Song, Ho-Young; Nam, Deok Ho; Ko, Heung Kyu; Park, Jung-Hoon; Na, Han Kyu; Lee, Jong Jin; Kang, Min Kyoung

    2014-11-01

    Placement of self-expandable nitinol stents is useful for the treatment of esophageal and upper gastrointestinal (GI) obstruction. However, complications such as stent migration, tumor overgrowth, and bleeding occur. Although stent migration and tumor overgrowth are well documented in previous studies, the occurrence of bleeding has not been fully evaluated. To evaluate the incidence, management strategies, and predictors of bleeding after placement of self-expandable nitinol stents in patients with esophageal and upper GI obstruction. We retrospectively reviewed the medical records and results of computed tomography and endoscopy of 1485 consecutive patients with esophageal and upper GI obstructions who underwent fluoroscopically guided stent placement. Bleeding occurred in 25 of 1485 (1.7%) patients 0 to 348 days after stent placement. Early stent-related bleeding occurred in 10 patients (40%) and angiographic embolization was used for 5/10. Late bleeding occurred in 15 patients (60%) and endoscopic hemostasis was used for 7/15. Twenty-two of 25 (88%) patients with bleeding had received prior radiotherapy and/or chemotherapy. Bleeding is a rare complication after placement of expandable nitinol stents in patients with esophageal and upper GI obstruction, but patients with early bleeding may require embolization for control. Care must be exercised on placing stents in patients who have received prior radiotherapy or chemotherapy. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  7. A torsional artificial muscle from twisted nitinol microwire

    Science.gov (United States)

    Mirvakili, Seyed M.; Hunter, Ian W.

    2017-04-01

    Nitinol microwires of 25 μm in diameter can have tensile actuation of up to 4.5% in less than 100 ms. A work density of up to 480 MPa can be achieved from these microwires. In the present work, we are showing that by twisting the microwires in form of closed-loop two-ply yarn we can create a torsional actuator. We achieved a revisable torsional stroke of 46°/mm with peak rotational speed of up to 10,000 rpm. We measured a gravimetric torque of up to 28.5 N•m/kg which is higher than the 3 - 6 N•m/kg for direct-drive commercial electric motors. These remarkable performance results are comparable to those of guest-infiltrated carbon nanotube twisted yarns.

  8. Deploying temporary networks for upscaling of sparse network stations

    Science.gov (United States)

    Coopersmith, Evan J.; Cosh, Michael H.; Bell, Jesse E.; Kelly, Victoria; Hall, Mark; Palecki, Michael A.; Temimi, Marouane

    2016-10-01

    Soil observations networks at the national scale play an integral role in hydrologic modeling, drought assessment, agricultural decision support, and our ability to understand climate change. Understanding soil moisture variability is necessary to apply these measurements to model calibration, business and consumer applications, or even human health issues. The installation of soil moisture sensors as sparse, national networks is necessitated by limited financial resources. However, this results in the incomplete sampling of the local heterogeneity of soil type, vegetation cover, topography, and the fine spatial distribution of precipitation events. To this end, temporary networks can be installed in the areas surrounding a permanent installation within a sparse network. The temporary networks deployed in this study provide a more representative average at the 3 km and 9 km scales, localized about the permanent gauge. The value of such temporary networks is demonstrated at test sites in Millbrook, New York and Crossville, Tennessee. The capacity of a single U.S. Climate Reference Network (USCRN) sensor set to approximate the average of a temporary network at the 3 km and 9 km scales using a simple linear scaling function is tested. The capacity of a temporary network to provide reliable estimates with diminishing numbers of sensors, the temporal stability of those networks, and ultimately, the relationship of the variability of those networks to soil moisture conditions at the permanent sensor are investigated. In this manner, this work demonstrates the single-season installation of a temporary network as a mechanism to characterize the soil moisture variability at a permanent gauge within a sparse network.

  9. Superficial femoral artery TASC D Registry: twelve-month effectiveness analysis of the Pulsar-18 SE nitinol stent in patients with critical limb ischemia.

    Science.gov (United States)

    Lichtenberg, M; Stahlhoff, W; Boese, D

    2013-08-01

    Single center observational study analyzing the primary patency rate and freedom from target lesions revascularization rate of the Pulsar-18 nitinol stent after recanalization of long superficial femoral artery (SFA) occlusions (TASC D) in 22 patients with critical limb ischemia (CLI). Between 1/2011 and 7/2011, 22 consecutive patients (9 male, 13 female) with chronic total occlusions (CTO) of the femoro-popliteal arteries presenting with CLI (17 patients with Rutherford 4 score, and 5 patients with Rutherford 5 score) were enrolled and successfully recanalized using the Pulsar-18 self-expanding (SE) nitinol stent (BIOTRONIK AG, Buelach, Switzerland). Primary patency at 12 months was defined as no binary restenosis (>50%) on Duplex ultrasound (PSVRPulsar-18 SE nitinol stent was 77% with a per protocol restenosis in 5 of 22 patients. Seventeen patients showed a walking capacity on treadmill test >300 meters (Rutherford II). Two patients with a documented restenosis were Rutherford, these patients were treated conservatively. Three patients with restenosis and a Rutherford III score were scheduled for an endovascular target lesion revascularization leading to a freedom from target lesion revascularization rate of 86%. Endovascular intervention of long SFA occlusions using subintimal or intraluminal recanalization technique with implantation of the Pulsar-18 SE nitinol stent in CLI patients is safe and clinically effective with a primary patency rate after 12 months of 77% and a freedom from target lesion revascularization rate of 86%.

  10. On phase transformation models for thermo-mechanically coupled response of Nitinol

    KAUST Repository

    Sengupta, Arkaprabha

    2011-03-31

    Fully coupled thermomechanical models for Nitinol at the grain level are developed in this work to capture the inter-dependence between deformation and temperature under non-isothermal conditions. The martensite transformation equations are solved using a novel algorithm which imposes all relevant constraints on the volume fractions. The numerical implementation of the resulting models within the finite element method is effected by the monolithic solution of the momentum and energy equations. Validation of the models is achieved by means of thin-tube experiments at different strain rates. © 2011 Springer-Verlag.

  11. Nitinol laser cutting: microstructure and functional properties of femtosecond and continuous wave laser processing

    Science.gov (United States)

    Biffi, C. A.; Tuissi, A.

    2017-03-01

    Thermal processing can affect the properties of smart materials, and the correct selection of the best manufacturing technology is fundamental for producing high tech smart devices, containing embedded functional properties. In this work cutting of thin superelastic Nitinol plates using a femtosecond (fs) and continuous wave (CW) laser was studied. Diamond shaped elements were cut to characterize the kerf qualitative features; microstructural analysis of the cross sections allowed identification of thermal damage characteristics introduced into the material during the laser processes. A thermally undamaged microstructure was observed for fs laser cutting, while CW was seen to be characterized by a large heat-affected zone. Functional properties were investigated by differential scanning calorimetry and tensile testing of laser cut microelements and of the reference material. It was seen that the martensitic transformation behavior of Nitinol is not affected by fs regime, while cw cutting provokes an effect equivalent to a high temperature thermal treatment in the material surrounding the cutting kerf, degradating the material properties. Finally, tensile testing indicated that superelastic performances were guaranteed by fs regime, while strong reduction of the recoverable strain was detected in the CW processed sample.

  12. Protection against productivity versus erosion vineyards. Testing of vegetal covers in slope crops

    International Nuclear Information System (INIS)

    Marques, M. J.; Ruiz-Colmenero, M.; Garcia-Munoz, S.; Cabello, F.; Munoz-Organero, G.; Perez-Jimenez, M. A.; Bienes, R.

    2009-01-01

    Temporary and permanent cover crops were used in three rain fed vineyards in the Center of Spain. They were sown in the middle of the strips to assess their ability to control erosion as well as their influence on grape production. Data from the year 2008 are compared with those obtained with traditional tillage treatment. The permanent cover formed by Brachypodium distachyon showed better ability to control erosion but it produced a decrease in production in young vines. barley and rye treatments were temporary covers, mowed in spring. They also reduced the erosion compared with the tillage however they did not appear to affect the vineyard production. (Author)

  13. Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes

    Directory of Open Access Journals (Sweden)

    McVeigh Elliot R

    2009-08-01

    Full Text Available Abstract Background Catheter visualization and tracking remains a challenge in interventional MR. Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance. Results The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm in vitro and in vivo in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability and antenna (signal attenuation properties. With this configuration, the temperature increase remained less than 2°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous in vitro and in vivo. Conclusion We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.

  14. Electrochemical, Polarization, and Crevice Corrosion Testing of Nitinol 60, A Supplement to the ECLSS Sustaining Materials Compatibility Study

    Science.gov (United States)

    Lee, R. E.

    2016-01-01

    In earlier trials, electrochemical test results were presented for six noble metals evaluated in test solutions representative of waste liquids processed in the Environmental Control and Life Support System (ECLSS) aboard the International Space Station (ISS). Subsequently, a seventh metal, Nitinol 60, was added for evaluation and subjected to the same test routines, data analysis, and theoretical methodologies. The previous six test metals included three titanium grades, (commercially pure, 6Al-4V alloy and 6Al-4V low interstitial alloy), two nickel-chromium alloys (Inconel(RegisteredTrademark) 625 and Hastelloy(RegisteredTrademark) C276), and one high-tier stainless steel (Cronidur(RegisteredTrademark) 30). The three titanium alloys gave the best results of all the metals, indicating superior corrosive nobility and galvanic protection properties. For this current effort, the results have clearly shown that Nitinol 60 is almost as noble as titanium, being very corrosion-resistant and galvanically compatible with the other six metals electrochemically and during long-term exposure. is also quite noble as it is very corrosion resistant and galvanically compatible with the other six metals from both an electrochemical perspective and long-term crevice corrosion scenario. This was clearly demonstrated utilizing the same techniques for linear, Tafel and cyclic polarization, and galvanic coupling of the metal candidate as was done for the previous study. The high nobility and low corrosion susceptibility for Nitinol 60 appear to be intermediate to the nickel/chromium alloys and the titanium metals with indications that are more reflective of the titanium metals in terms of general corrosion and pitting behavior.

  15. Clinical impact and risk stratification of balloon angioplasty for femoropopliteal disease in nitinol stenting era: Retrospective multicenter study using propensity score matching analysis

    Directory of Open Access Journals (Sweden)

    Taketsugu Tsuchiya

    2016-07-01

    Full Text Available Objective: Nitinol stenting could bring the better outcome in endovascular therapy for femoropopliteal disease. However, it might be expected that recent marked advances in both device technology and operator technique had led to improved efficacy of balloon angioplasty even in this segment. The aims of this study were to evaluate the clinical impact of balloon angioplasty for femoropopliteal disease and make risk stratification clear by propensity score matching analysis. Methods: Based on the multicenter retrospective data, 2758 patients (balloon angioplasty: 729 patients and nitinol stenting: 2029 patients, those who underwent endovascular therapy for femoropopliteal disease, were analyzed. Results: The propensity score matching procedure extracted a total of 572 cases per group, and the primary patency rate of balloon angioplasty and nitinol stenting groups after matching was significantly the same (77.2% vs 82.7% at 1 year; 62.2% vs 64.3% at 3 years; 47.8% vs 54.3% at 5 years. In multivariate Cox hazard regression analysis, significant predictors for primary patency were diabetes mellitus, regular dialysis, cilostazol use, chronic total occlusion, and intra-vascular ultra-sonography use. The strategy of balloon angioplasty was not evaluated as a significant predictor for the primary patency. After risk stratification using five items (diabetes mellitus, regular dialysis, no use of intra-vascular ultra-sonography, chronic total occlusion, and no use of cilostazol: the DDICC score, the estimated primary patency rates of each group (low, DDICC score 0–2; moderate, DDICC score 3; high risk, DDICC score 4–5 were 88.6%, 78.3%, and 63.5% at 1 year; 75.2%, 60.7%, and 39.8% at 3 years; and 66.0%, 47.1%, and 26.3% at 5 years (p < 0.0001. The primary patency rate of balloon angioplasty and nitinol stenting groups was significantly the same in each risk stratification. Conclusion: This study suggests that balloon angioplasty does

  16. Effect of biologically active coating on biocompatibility of Nitinol devices designed for the closure of intra-atrial communications

    NARCIS (Netherlands)

    Kong, XQ; Grabitz, RG; van Oeveren, W; Klee, D; van Kooten, TG; Freudenthal, F; Qing, M; von Bernuth, G; Seghaye, MC

    Anti-thrombogenicity and rapid endothelialisation are prerequisites for the use of closure devices of intra-atrial communications in order to reduce the risk of cerebral embolism. The purpose of this study was therefore to assess the effect of bioactive coatings on biocompatibility of Nitinol coils

  17. Biomedical engineering in design and application of nitinol stents with shape memory effect

    Science.gov (United States)

    Ryklina, E. P.; Khmelevskaya, I. Y.; Morozova, Tamara V.; Prokoshkin, S. D.

    1996-04-01

    Our studies in the field of endosurgery in collaboration with the physicians of the National Research Center of Surgery of the Academy of Medical Sciences are carried out beginning in 1983. These studies laid the foundation for the new direction of X-ray surgery--X-ray Nitinol stenting of vessels and tubular structures. X-ray nitinol stents are unique self-fixing shells based on the shape memory effect and superelasticity of nickel-titanium alloys self- reconstructed under human body temperature. Applied for stenting of arteries in cases of stenosis etc., bile ducts in cases of benign and malignant stenoses, digestive tract in cases of oesophageal cancer and cervical canal uterus in cases of postsurgical atresiss and strictures of uterine. The purpose of stenting is restoration of the shape of artery or tubular structure by a cylinder frame formation. The especially elaborated original method of stenting allows to avoid the traditional surgical operation, i.e. the stenting is performed without blood, narcosis and surgical knife. The stent to be implanted is transported into the affected zone through the puncture under the X-ray control. Clinical applications of X-ray endovascular stenting has been started in March 1984. During this period nearly 400 operations on stenting have been performed on femoral, iliac, brachio-cephalic, subclavian arteries, bile ducts, tracheas, digestive tract and cervical canal uterus.

  18. Nitinol Embolic Protection Filters: Design Investigation by Finite Element Analysis

    Science.gov (United States)

    Conti, Michele; de Beule, Matthieu; Mortier, Peter; van Loo, Denis; Verdonck, Pascal; Vermassen, Frank; Segers, Patrick; Auricchio, Ferdinando; Verhegghe, Benedict

    2009-08-01

    The widespread acceptance of carotid artery stenting (CAS) to treat carotid artery stenosis and its effectiveness compared with surgical counterpart, carotid endarterectomy (CEA), is still a matter of debate. Transient or permanent neurological deficits may develop in patients undergoing CAS due to distal embolization or hemodynamic changes. Design, development, and usage of embolic protection devices (EPDs), such as embolic protection filters, appear to have a significant impact on the success of CAS. Unfortunately, some drawbacks, such as filtering failure, inability to cross tortuous high-grade stenoses, malpositioning and vessel injury, still remain and require design improvement. Currently, many different designs of such devices are available on the rapidly growing dedicated market. In spite of such a growing commercial interest, there is a significant need for design tools as well as for careful engineering investigations and design analyses of such nitinol devices. The present study aims to investigate the embolic protection filter design by finite element analysis. We first developed a parametrical computer-aided design model of an embolic filter based on micro-CT scans of the Angioguard™ XP (Cordis Endovascular, FL) EPD by means of the open source pyFormex software. Subsequently, we used the finite element method to simulate the deployment of the nitinol filter as it exits the delivery sheath. Comparison of the simulations with micro-CT images of the real device exiting the catheter showed excellent correspondence with our simulations. Finally, we evaluated circumferential basket-vessel wall apposition of a 4 mm size filter in a straight vessel of different sizes and shape. We conclude that the proposed methodology offers a useful tool to evaluate and to compare current or new designs of EPDs. Further simulations will investigate vessel wall apposition in a realistic tortuous anatomy.

  19. The Effect of Various Quenchants on the Hardness and Microstructure of 60-NITINOL

    Science.gov (United States)

    Thomas, Fransua

    2015-01-01

    The effect of various quenching media on the hardness and microstructure of 60 NITINOL (60 NiTi) were evaluated. Specimens of 60 NiTi were heat treated in air at 1000 degC for 30 min or 2 hr, then quench cooled by one of seven different methods. The microstructure and hardness of this material was examined post heat treatment. The results indicated that the quench method had little effect on the resulting hardness and microstructure of 60 NiTi.

  20. Pan-nitinol occluder and special delivery device for closure of patent ductus arteriosus: a canine-model feasibility study.

    Science.gov (United States)

    Jiang, Hai-bin; Bai, Yuan; Zong, Gang-jun; Han, Lin; Li, Wei-ping; Lu, Yang; Qin, Yong-wen; Zhao, Xian-xian

    2013-01-01

    The aim of this study was to evaluate a new type of occluder for patent ductus arteriosus. Patent ductus arteriosus was established in a canine model by anastomosing a length of autologous jugular vein to the descending aorta and the left pulmonary artery in an end-to-side fashion. Transcatheter closure of each patent ductus arteriosus was performed on 10 dogs, which were then monitored for as long as 6 months with aortography, echocardiography, and histologic evaluation. Transcatheter closure with use of the novel pan-nitinol device was successful in all canine models. Postoperative echocardiography showed that the location and shape of the occluders were normal, without any residual shunting. Further histologic evaluation confirmed that the occluder surface was completely endothelialized 3 months after implantation. Transcatheter patent ductus arteriosus closure with the pan-nitinol occluder can be performed safely and successfully in a canine model and shows good biological compatibility and low mortality rates.

  1. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung; Lee, Yeoun Joo

    2013-01-01

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  2. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung [Dept. of University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Yeoun Joo [Dept. of Pediatrics, Pusan National University Children' s Hospital, Yangsan (Korea, Republic of)

    2013-06-15

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  3. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. 25 CFR 11.607 - Temporary orders and temporary injunctions.

    Science.gov (United States)

    2010-04-01

    ... injunction: (1) Does not prejudice the rights of the parties or the child which are to be adjudicated at... temporary maintenance or temporary support of a child of the marriage entitled to support. The motion shall... the peace of the other party or of any child; (3) Excluding a party from the family home or from the...

  5. Wireless implantable chip with integrated nitinol-based pump for radio-controlled local drug delivery.

    Science.gov (United States)

    Fong, Jeffrey; Xiao, Zhiming; Takahata, Kenichi

    2015-02-21

    We demonstrate an active, implantable drug delivery device embedded with a microfluidic pump that is driven by a radio-controlled actuator for temporal drug delivery. The polyimide-packaged 10 × 10 × 2 mm(3) chip contains a micromachined pump chamber and check valves of Parylene C to force the release of the drug from a 76 μL reservoir by wirelessly activating the actuator using external radio-frequency (RF) electromagnetic fields. The rectangular-shaped spiral-coil actuator based on nitinol, a biocompatible shape-memory alloy, is developed to perform cantilever-like actuation for pumping operation. The nitinol-coil actuator itself forms a passive 185 MHz resonant circuit that serves as a self-heat source activated via RF power transfer to enable frequency-selective actuation and pumping. Experimental wireless operation of fabricated prototypes shows successful release of test agents from the devices placed in liquid and excited by radiating tuned RF fields with an output power of 1.1 W. These tests reveal a single release volume of 219 nL, suggesting a device's capacity of ~350 individual ejections of drug from its reservoir. The thermal behavior of the activated device is also reported in detail. This proof-of-concept prototype validates the effectiveness of wireless RF pumping for fully controlled, long-lasting drug delivery, a key step towards enabling patient-tailored, targeted local drug delivery through highly miniaturized implants.

  6. The Measurement and Interpretation of Transformation Temperatures in Nitinol

    Science.gov (United States)

    Duerig, T. W.; Pelton, A. R.; Bhattacharya, K.

    2017-12-01

    A previous paper (Duerig and Bhattacharya in Shap Mem Superelasticity 1:153-161, 2015) introduced several engineering considerations surrounding the R-phase in Nitinol and highlighted a common, if not pervasive, misconception regarding the use of the term Af by the medical device industry. This paper brings additional data to bear on the issue and proposes more accurate terminology. Moreover, a variety of tools are used to establish the forward and reverse stress-temperature phase diagrams for a superelastic wire typical of that used in medical devices. Once established, the two most common methods of measuring transformation temperatures, Differential Scanning Calorimetry and Bend Free Recovery, are tested against the observed behavior. Light is also shed upon the origin of the Clausius-Clapeyron ratio (d σ/d T), the triple point, and why such large variations are reported in superelastic alloys.

  7. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  8. Characterization of the temporary radiation workforce at US nuclear power plants

    International Nuclear Information System (INIS)

    Cehn, J.I.

    1984-01-01

    The temporary radiation worker is the subject of this recent study by the National Environmental Studies Project. ''Lenny'', an imaginary worker, is actually a composite of the estimated 22,000 radiation workers employed at various times at the 80 nuclear power plants in the U.S. Lenny reports to a trailer on the plant site to check in and spends the next day and a half in a training class that covers radiation safety, federal regulations and exposure limits and plant procedures. He must take and pass a written exam, then he fills out a medical history, indicating whether or not he has received any industrial radiation exposure. After three days of training and ''processing'' he dons a radiation measuring dosimeter and begins work. A key question to this study is whether the temporary employees are getting assigned the dirty work. It has been alleged that temps are used as ''glowboys'' or ''radiation sponges''. The new study finds no basis for this allegation. Data show that permanent plant staff received nearly the same average annual radiation dose as temporary employees

  9. Temporary employment and health: a review.

    Science.gov (United States)

    Virtanen, Marianna; Kivimäki, Mika; Joensuu, Matti; Virtanen, Pekka; Elovainio, Marko; Vahtera, Jussi

    2005-06-01

    We aimed to review evidence on the relationship between temporary employment and health, and to see whether the association is dependent on outcome measure, instability of employment, and contextual factors. We systematically searched for studies of temporary employment and various health outcomes and critically appraised 27 studies. The review suggests higher psychological morbidity among temporary workers compared with permanent employees. According to some studies, temporary workers also have a higher risk of occupational injuries but their sickness absence is lower. Morbidity may be higher in temporary jobs with high employment instability and in countries with a lower number of temporary workers and unemployed workers. The evidence indicates an association between temporary employment and psychological morbidity. The health risk may depend on instability of temporary employment and the context. Confounding by occupation may have biased some of the studies. Additional research to clarify the role of employment instability, hazard accumulation, and selection is recommended.

  10. 5 CFR 213.3199 - Temporary organizations.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Temporary organizations. 213.3199 Section... SERVICE Excepted Schedules Schedule A § 213.3199 Temporary organizations. Positions on the staffs of temporary organizations, as defined in 5 U.S.C. 3161(a). Appointments may not exceed 3 years, but temporary...

  11. 42 CFR 488.415 - Temporary management.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Temporary management. 488.415 Section 488.415... Compliance for Long-Term Care Facilities with Deficiencies § 488.415 Temporary management. (a) Definition. Temporary management means the temporary appointment by CMS or the State of a substitute facility manager or...

  12. 32 CFR 147.30 - Temporary eligibility for access at the confidential and secret levels and temporary eligibility...

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Temporary eligibility for access at the confidential and secret levels and temporary eligibility for âLâ access authorization. 147.30 Section 147.30... Temporary Access § 147.30 Temporary eligibility for access at the confidential and secret levels and...

  13. Environmental effectiveness of GAEC cross-compliance Standard 1.1a (temporary ditches and 1.2g (permanent grass cover of set-aside in reducing soil erosion and economic evaluation of the competitiveness gap for farmers

    Directory of Open Access Journals (Sweden)

    Paolo Bazzoffi

    2016-02-01

    Full Text Available This paper shows the results of the monitoring carried out in three hilly farms of the MONACO project in order to verify the effectiveness of the Standard 1.1 (commitment a (temporary ditches and Standard 1.2 (commitment g (Vegetation cover throughout the year in set-aside land in the reduction in soil erosion, contained in Rule 1: ‘minimum land management that meets specific conditions’ of the decree Mipaaf 2009 and following modifications, until the recent decree No. 180 of January 23, 2015. In addition, the assessment of the competitiveness gap was done. That is the evaluation of the additional costs borne by the beneficiary of the single payment determined from agronomic commitments. Monitoring has also compared the erosion actually observed in the field with that predicted by RUSLE model (Revised Universal Soil Loss Equation (Renard et al., 1997 in the two situations: with and without the presence of temporary ditches, i.e. assuming Factual (compliance rules and in that Counterfactual (infringement. This comparison was made in view of the fact that the RUSLE model was chosen by the 'European Evaluation Network for Rural Development (EEN, 2013 as a forecasting tool for the quantification of' Common Indicator ‘soil erosion by water’. The results of soil erosion survey carried out by using a new  UAV-GIS methodology  on two monitoring farms in two years of observations have shown that temporary ditches were effective in decreasing erosion, on average, by 42.5%, from 36. 59 t ha-1 to 21.05 t ha-1 during the monitoring period. It was also evaluated the effectiveness of grass strips (at variance with the commitment of temporary ditches. The results showed a strong, highly significant, reduction in erosion by about 35% times respect soil erosion observed in bare soil and also a significant reduction in the volume of runoff water.  With regard to Standard 1.2 (commitment g the statistical analysis shows a strong and highly significant

  14. The Temporary Leave Dilemma -

    DEFF Research Database (Denmark)

    Amilon, Anna

    2010-01-01

    Lone mothers have to take care of a sick child with little or no help from the child’s other parent and have to carry all costs connected to leave-taking. This paper empirically tests whether lone mothers take more temporary parental leave to care for sick children than partnered mothers...... and whether parental leave is associated with a signaling cost. The results from this study of Swedish mothers show that lone mothers use more temporary parental leave than partnered mothers. Further, within the group of lone mothers, those with higher socioeconomic status take less temporary parental leave...... than those with lower socioeconomic status, whereas no such differences are found within the group of partnered mothers. One possible interpretation is that signaling costs negatively influence the utilization of temporary parental leave for lone mothers....

  15. Improved results of the vacuum assisted closure and Nitinol clips sternal closure after postoperative deep sternal wound infection.

    Science.gov (United States)

    Tocco, Maria Pia; Costantino, Alberto; Ballardini, Milva; D'Andrea, Claudio; Masala, Marcello; Merico, Eusebio; Mosillo, Luigi; Sordini, Paolo

    2009-05-01

    Postoperative deep sternal wound infection is a severe complication of cardiac surgery, with a high mortality rate and a high morbidity rate. The objective of this prospective study is to report our experience with the vacuum assisted closure (VAC) system for the management of deep wound infection. We also devised an innovative closure technique post VAC therapy using thermo reactive clips. The advantage of this technique is that the posterior face of the sternum does not have to be separated from the mediastinal structures thus minimising the risk of damage. From October 2006 to October 2008, we prospectively evaluated 21 patients affected by mediastinitis after sternotomy. Nineteen patients had sternotomy for coronary artery bypass grafting (CABG), one patient for aortic valve replacement (AVR) and another one for ascending aortic replacement (AAR). All patients were treated with the VAC system at the time of infection diagnosis. When the wound tissue appeared viable and the microbiological cultures were negative, the chest was closed using the most suitable procedure for the patient in question; nine patients were closed using pectoralis flaps, nine patients using Nitinol clips, one patient with a combined technique (use of Nitinol clips and muscle flap), one patient with a direct wound closure and another patient, who needed AAR with a homograft performed in another institution, was closed using sternal wires. We had no mortality; wound healing was successfully achieved in all patients. In more than 50% of the patients, the VAC therapy allowed direct sternal resynthesis. The average duration of the vacuum therapy was 26 days (range 14-37 days). VAC is a safe and effective option in the treatment of post-sternotomy mediastinitis, with excellent survival and immediate improvement of local wound conditions; furthermore, the use of Nitinol clips after VAC therapy demonstrated to be a safe and non-invasive option for sternal resynthesis. After VAC therapy, a

  16. 78 FR 2273 - Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing

    Science.gov (United States)

    2013-01-10

    ... introduces or causes the introduction of one or more of the test products into interstate commerce, but not... permit covers limited interstate marketing tests of products identified as ``no drain canned tuna... permit provides for the temporary marketing of a total 533,333 cases of 12 x 4 ounce cans (totaling 6.4...

  17. Effect of a novel load-bearing trabecular Nitinol scaffold on rabbit radius bone regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Gotman, Irena, E-mail: gotman@technion.ac.il; Gutmanas, Elazar Y., E-mail: gutmanas@technion.ac.il [Department of Materials Science and Engineering, Techion-Israel Institute of Technology, Haifa, 32000 Israel (Israel); National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Zaretzky, Asaph [The Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, 31096 Israel (Israel); Psakhie, Sergey G. [National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation); Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation)

    2015-10-27

    The research aim was to evaluate the bone regeneration capability of novel load-bearing NiTi alloy (Nitinol) scaffolds in a critical-size defect (CSD) model. High strength “trabecular Nitinol” scaffolds were prepared by PIRAC (Powder Immersion Reaction Assisted Coating) annealing of the highly porous Ni foam in Ti powder at 900°C. This was followed by PIRAC nitriding to mitigate the release of potentially toxic Ni ions. Scaffolds phase composition and microstructure were characterized by X-ray diffraction and scanning electron microscopy (SEM/EDS), and their mechanical properties were tested in compression. New Zealand white rabbits received bone defect in right radius and were divided in four groups randomly. In the control group, nothing was placed in the defect. In other groups, NiTi scaffolds were implanted in the defect: (i) as produced, (ii) loaded with bone marrow aspirate (BMA), and (iii) biomimetically CaP-coated. The animals were sacrificed after 12 weeks. The forelimbs with scaffolds were resected, fixed, sectioned and examined in SEM. New bone formation inside the scaffold was studied by EDS analysis and by the processing of backscattered electron images. Bone ingrowth into the scaffold was observed in all implant groups, mostly next to the ulna. New bone formation was strongly enhanced by BMA loading and biomimeatic CaP coating, the bone penetrating as much as 1–1.5 mm into the scaffold. The results of this preliminary study demonstrate that the newly developed high strength trabecular Nitinol scaffolds can be successfully used for bone regeneration in critical size defects.

  18. Employment protection and temporary work agencies

    OpenAIRE

    Baumann, Florian; Mechtel, Mario; Stähler, Nikolai

    2008-01-01

    Employers who use temporary agency staff in contrast to regular staff are not affected by employment protection regulations when terminating a job. Therefore, services provided by temporary work agencies may be seen as a substitute for regular employment. In this paper, we analyze the effects of employment protection on the size of the temporary work agency sector in a model of equilibrium unemployment. We find that higher firing costs may even reduce temporary work agency employment if agenc...

  19. The temporary international collective chronicle

    International Nuclear Information System (INIS)

    Kravchenko, Yu.Ya.

    2007-01-01

    The temporary international collective brief history is presented from the time of its establishment in 1972 (and even earlier) till the termination of its activity in 1990 (and even later). Works in the temporary international collective framework demonstrate an example of successful cooperation of specialists from different countries in the field of calculation-theoretical and experimental research on the WWER reactor physics. The results of experimental and calculation studies were reported to the topical meetings, workshops, conferences, and symposia as well as were published in the temporary international collective reports and proceedings. The answers to the questions about the temporary international collective activity-What? Where? When?-are presented in this chronicle (Authors)

  20. 32 CFR 147.31 - Temporary eligibility for access at the top secret levels and temporary eligibility for “Q...

    Science.gov (United States)

    2010-07-01

    ... Guidelines for Temporary Access § 147.31 Temporary eligibility for access at the top secret levels and... 32 National Defense 1 2010-07-01 2010-07-01 false Temporary eligibility for access at the top secret levels and temporary eligibility for âQâ access authorization: For someone who is the subject of a...

  1. 32 CFR 147.32 - Temporary eligibility for access at the top secret and SCI levels and temporary eligibility for...

    Science.gov (United States)

    2010-07-01

    ... Guidelines for Temporary Access § 147.32 Temporary eligibility for access at the top secret and SCI levels... 32 National Defense 1 2010-07-01 2010-07-01 false Temporary eligibility for access at the top secret and SCI levels and temporary eligibility for âQâ access authorization: For someone who is not the...

  2. 36 CFR 13.182 - Temporary facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Temporary facilities. 13.182... NATIONAL PARK SYSTEM UNITS IN ALASKA Cabins Use of Temporary Facilities Related to Taking Fish and Wildlife § 13.182 Temporary facilities. In a national preserve where the taking of fish and wildlife is...

  3. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults.

    Science.gov (United States)

    Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam

    2017-09-01

    Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.

  4. Evaluation of the small intestinal submucosa covered stent in preventing restenosis after percutaneous transluminal angioplasty in the swine

    International Nuclear Information System (INIS)

    Wang Xiaobai; Li Jinglei; Zhang Hong; Zhang Yan

    2012-01-01

    Objective: To compare the performance of small intestinal submucosa (SIS)-covered endografts (SCEs) to bare nitinol stents (BSs) in injured swine iliac arteries. Materials and methods: Twenty-eight nitinol stents were used: 14 externally SCEs and 14 BSs. Devices were implanted in each side of balloon-injured external iliac arteries of 14 swine via carotid approach. Arteriograms were obtained before and after implantation and before animal sacrifice at 4, 8, and 12 weeks. Histopathological and electron microscopy studies of explanted specimens were performed. Results: Implantation of all SCEs and BSs was technically successful, but one SCE and one BS were obstructed at 8 weeks after implantation. At sacrifice, the other 26 stents were patent, with angiogram showing no significant different luminal narrowing between SCEs and BSs. Proliferating cell nuclear antigen (PCNA) immunohistochemistry examination revealed that the percentage of PCNA(+) cells were lower in SCEs (p < 0.05). Additionally, histomorphological analysis indicated that the neointima area and percentage of narrowing area were greater in SCEs, but there was no statistical significance. Greater endothelial cell count in SCEs than in BSs per visual field at 4000 times magnification by scanning electron microscope (p < 0.05). Conclusion: Compared to BSs, no definite decrease of neointima and restenosis was found in SCEs in the present study. However, it is effective in promoting endothelial regeneration and strengthening endothelial function.

  5. Temporary labour contracts

    CERN Document Server

    1999-01-01

    The five contracts for Temporary Labour assignments on the CERN site (L020/PE, L021/PE, L022/PE, L023/PE and L024/PE) approved by the Finance Committee in March 1996 (CERN/FC/3857) will reach the end of their initial three-year contractual period at the end of December 1999. Following the satisfactory execution of these contracts during this period, CERN requests approval to extend them from January 2000 for the first of the two years foreseen in the original adjudication. The Finance Committee is invited: - to take note that the three-year expenditure for Temporary Labour contracts from 1997 to 1999 will not exceed 19 100 000 Swiss francs, compared to the 18 900 000 Swiss francs estimated at the time of the adjudication in March 1996; - to approve an extension of the present Temporary Labour contracts for the year 2000 for a total amount not exceeding 6 000 000 Swiss francs.

  6. The Effect of Hydroxyapatite Coatings on the Passivation Behavior of Oxidized and Unoxidized Superelastic Nitinol Alloys

    Science.gov (United States)

    Etminanfar, M. R.; Khalil-Allafi, J.; Sheykholeslami, S. O. R.

    2018-02-01

    Nitinol alloys have been used in various biological applications due to their superior properties. In this study, a bipolar pulsed current electrodeposition technique was applied to produce a hydroxyapatite (HA) film on the Nitinol alloy. Also, the protection performance of the coating was evaluated on both abraded and thermochemically modified alloy. According to obtained data, reducing the electrocrystallization rate by the pulse deposition technique can promote HA formation on both abraded and modified substrates. Based on scanning electron microscopy and high-resolution transmission electron microscopy data, the HA coatings revealed a flake-like morphology and each flake was composed of nano-crystalline grains. Atomic force microscopy images revealed that flakes on the abraded substrate were smaller in size than that of the modified alloy. Comparing the corrosion resistance of the bare substrates revealed that the modified alloy has a higher corrosion resistance than the abraded alloy and the modified surface is well passivized during anodic polarization in Ringer's solution. However, this condition is reversed after the deposition of HA film. It seems that because of the lower crystallization sites on the abraded alloy, the produced HA film is denser and more protective against the corrosive mediums as compared to the coating on the modified alloy. Although the HA coating can improve the bioactivity of both substrates, the resulted film on the oxidized alloy is porous and deteriorates the implant permanence in the vicinity of body fluids.

  7. 77 FR 71825 - Notice of Temporary Restriction of Vehicle Use and Temporary Closure to Tree Cutting and Wood...

    Science.gov (United States)

    2012-12-04

    ... to Tree Cutting and Wood Harvesting on Public Land in Douglas County, NV AGENCY: Bureau of Land... a temporary closure to wood harvesting and/or tree cutting on public land within the Topaz Ranch... temporary restriction of cross-country vehicle travel and a temporary closure to tree cutting and wood...

  8. PEACE I all-comers registry: patency evaluation after implantation of the 4-French Pulsar-18 self-expanding nitinol stent in femoropopliteal lesions.

    Science.gov (United States)

    Lichtenberg, Michael; Kolks, Oliver; Hailer, Birgit; Stahlhoff, Wilhelm-Friedrich; Tiefenbacher, Christiane; Nolte-Ernsting, Claus; Arjumand, Jawed; Wittenberg, Guenther

    2014-06-01

    To evaluate the 1-year patency of the 4-F Pulsar-18 self-expanding nitinol stent for treatment of femoropopliteal occlusive disease in a national, prospective, multicenter, all-comers registry. Between January and June 2012, the German PEACE I all-comers prospective registry enrolled 148 patients with symptomatic femoropopliteal lesions (Rutherford category 2-5) undergoing recanalization and implantation of the Pulsar-18 SE nitinol stent at 6 clinical centers. Thirty patients did not have the 12-month follow-up visit (18 declined reevaluation, 5 withdrew consent, and 7 died), leaving 118 patients (64 men; mean 71.9±9.6 age years) for the 1-year evaluation. The average lesion length was 111.5±71.4 mm, and 38 of the 118 lesions were classified as TASC II D. More than half the lesions (67, 56.7%) were chronic total occlusions (CTO). The popliteal segment was involved in 22 (18.7%) lesions. The mean stented length was 122.7±64.5 mm. Routine follow-up included duplex ultrasound at 6 and 12 months. Outcome measures were primary patency and no clinically driven target lesion revascularization (TLR) within 12 months. The overall primary patency rates after 6 and 12 months were 87.4% and 79.5%, respectively; in the popliteal segments, the rate was 71.4% after 12 months. The overall freedom from TLR was 93.2% after 6 months and 81% after 12 months. Ankle-brachial index, pain-free walking distance, and Rutherford category all improved significantly (pPulsar-18 self-expanding nitinol stent in femoropopliteal lesions averaging 111.5 mm long showed promising primary patency and freedom from TLR after 6 and 12 months. Diabetes had no negative impact on patency. Primary patency in the popliteal segments was acceptable at 12 months.

  9. Self-Expanding Nitinol Renal Artery Stents: Comparison of Safety and Efficacy of Bare Versus Polyzene-F Nanocoated Stents in a Porcine Model

    International Nuclear Information System (INIS)

    Kurz, P.; Stampfl, U.; Christoph, P.; Henn, C.; Satzl, S.; Radeleff, B.; Berger, I.; Richter, G. M.

    2011-01-01

    Objective: To investigate the safety and efficacy of a Polyzene-F nanocoat on new low-profile self-expandable nitinol stents in minipig renal arteries. Materials and Methods: Ten bare nitinol stents (BNS) and 10 stents coated with a 50 nm-thin Polyzene-F coating were randomly implanted into renal arteries of 10 minipigs (4- and 12-week follow-up, 5 animals/group). Thrombogenicity, on-stent surface endothelialization, vessel wall injury, late in-stent stenosis, and peristrut vessel wall inflammation were determined by quantitative angiography and postmortem histomorphometry. Results: In 6 of 10 BNS, >50% stenosis was found, but no stenosis was found in stents with a nanothin Polyzene-F coating. Histomorphometry showed a statistically significant (p < 0.05) different average maximum luminal loss of 55.16% ± 8.43% at 12 weeks in BNS versus 39.77% ± 7.41% in stents with a nanothin Polyzene-F coating. Stents with a nanothin Polyzene-F coating had a significantly (p < 0.05) lower inflammation score after 12 weeks, 1.31 ± 1.17 versus 2.17 ± 0.85 in BNS. The results for vessel wall injury (0.6 ± 0.58 for Polyzene-F-coated stents; 0.72 ± 0.98 for BNS) and re-endothelialization, (1.16 ± 0.43 and 1.23 ± 0.54, respectively) were not statistically significant at 12-week follow-up. No thrombus deposition was observed on the stents at either follow-up time point. Conclusion: Nitinol stents with a nanothin Polyzene-F coating successfully decreased in-stent stenosis and vessel wall inflammation compared with BNS. Endothelialization and vessel wall injury were found to be equal. These studies warrant long-term pig studies (≥120 days) because 12 weeks may not be sufficient time for complete healing; thereafter, human studies may be warranted.

  10. 30 CFR 47.44 - Temporary, portable containers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Temporary, portable containers. 47.44 Section... TRAINING HAZARD COMMUNICATION (HazCom) Container Labels and Other Forms of Warning § 47.44 Temporary, portable containers. (a) The operator does not have to label a temporary, portable container if he or she...

  11. Temporary physical protection systems

    International Nuclear Information System (INIS)

    Williams, J.D.; Gangel, D.J.; Madsen, R.W.

    1991-01-01

    Terrorism and other aspects of world political instability have created a high demand for temporary physical protection systems within the nuclear materials management community. They can be used when vehicles carrying important assets are away from their permanent fixed site location, around areas where experiments are being temporarily conducted, around construction areas and one portions of a fixed site physical security system which is temporarily inoperable. Physical security systems can be grouped into four categories: tactical, portable, semi-permanent, and fixed. The resources and experience gained at Sandia National Laboratories in over forty years of developing and implementing security systems for protecting nuclear weapons and fixed nuclear facilities is now being applied to temporary physical security systems. This paper emphasizes temporary physical security systems and their component parts that are presently available and identify additional system-subsystem objectives, requirements, and concepts

  12. KTP laser stapedotomy with a self-crimping, thermal shape memory Nitinol piston: follow-up study reporting intermediate-term hearing.

    Science.gov (United States)

    Gerlinger, Imre; Bakó, Péter; Piski, Zalán; Révész, Péter; Ráth, Gábor; Karosi, Tamás; Lujber, László

    2014-12-01

    The aim of this study was an evaluation of the mid-term hearing results after the implantation of a self-crimping heat memory Nitinol piston in stapes surgery. The 12-month postoperative results were compared with those at a minimum of 3 years (maximum 6.7, average 4.4 years). The medical records of all 44 patients who underwent surgery with a Nitinol piston for stapes fixation between November 2005 and January 2007 were evaluated retrospectively. The prostheses used in all cases measured either 4.5 or 4.75 × 0.6 mm. We hypothesized that the 12-month postoperative hearing results would be permanent after an average follow-up of 4.4 years. Thirty-two of the 44 consecutive patients were females and 12 were males. Their mean age was 40.4 years (range 27-69). All underwent a 12-month postoperative audiometric evaluation. 38 (30 females, 8 males, average age 45, range 28-77 years) of the 44 were available for mid-term 4.4-year (minimum 3 years, maximum 6.7 years) postoperative audiometric evaluation. The mean air-bone gap (ABG) for the frequencies 0.5, 1, 2 and 3 kHz at the 12-month postoperative follow-up was 11 dB (SD 4.1) and that after an average 4.4-year postoperative evaluation was 6.4 dB (SD 3.6). The mean decrease in ABG after 12 months was 19.5 dB, and that after the average 4.4 years was 21.3 dB. ABG closure within 10 dB was achieved in 77.2 % after 12 months and in 89.5 % after the average 4.4 years. No patient with an ABG > 20 dB was recorded after the average 4.4 years. The mean air conduction threshold at 4 kHz was examined pre and postoperatively so as to indicate any possible inner ear damage. At the 12-month follow-up, the difference between the pre and postoperative values was -2.5 dB, whereas after the average 4.4 years the difference was surprisingly +13 dB. The individual AC improvements were also demonstrated with the use of Amsterdam Hearing Evaluation Plots (AHEPs). The Nitinol prosthesis allowed excellent intraoperative handling and no

  13. Temporary workers

    NARCIS (Netherlands)

    Klein Hesselink, J.; Verbiest, S.; Goudswaard, A.

    2014-01-01

    Temporary employment contracts are often used by employers to manage fluctuations in personnel needs. Many sectors of industry experience these fluctuations, which are often seasonal. This creates uncertainty about the continuousness of demand for work, which is transferred from employers to

  14. Wetlands in changed landscapes: the influence of habitat transformation on the physico-chemistry of temporary depression wetlands.

    Science.gov (United States)

    Bird, Matthew S; Day, Jenny A

    2014-01-01

    Temporary wetlands dominate the wet season landscape of temperate, semi-arid and arid regions, yet, other than their direct loss to development and agriculture, little information exists on how remaining wetlands have been altered by anthropogenic conversion of surrounding landscapes. This study investigates relationships between the extent and type of habitat transformation around temporary wetlands and their water column physico-chemical characteristics. A set of 90 isolated depression wetlands (seasonally inundated) occurring on coastal plains of the south-western Cape mediterranean-climate region of South Africa was sampled during the winter/spring wet season of 2007. Wetlands were sampled across habitat transformation gradients according to the areal cover of agriculture, urban development and alien invasive vegetation within 100 and 500 m radii of each wetland edge. We hypothesized that the principal drivers of physico-chemical conditions in these wetlands (e.g. soil properties, basin morphology) are altered by habitat transformation. Multivariate multiple regression analyses (distance-based Redundancy Analysis) indicated significant associations between wetland physico-chemistry and habitat transformation (overall transformation within 100 and 500 m, alien vegetation cover within 100 and 500 m, urban cover within 100 m); although for significant regressions the amount of variation explained was very low (range: ∼2 to ∼5.5%), relative to that explained by purely spatio-temporal factors (range: ∼35.5 to ∼43%). The nature of the relationships between each type of transformation in the landscape and individual physico-chemical variables in wetlands were further explored with univariate multiple regressions. Results suggest that conservation of relatively narrow (∼100 m) buffer strips around temporary wetlands is likely to be effective in the maintenance of natural conditions in terms of physico-chemical water quality.

  15. Wetlands in changed landscapes: the influence of habitat transformation on the physico-chemistry of temporary depression wetlands.

    Directory of Open Access Journals (Sweden)

    Matthew S Bird

    Full Text Available Temporary wetlands dominate the wet season landscape of temperate, semi-arid and arid regions, yet, other than their direct loss to development and agriculture, little information exists on how remaining wetlands have been altered by anthropogenic conversion of surrounding landscapes. This study investigates relationships between the extent and type of habitat transformation around temporary wetlands and their water column physico-chemical characteristics. A set of 90 isolated depression wetlands (seasonally inundated occurring on coastal plains of the south-western Cape mediterranean-climate region of South Africa was sampled during the winter/spring wet season of 2007. Wetlands were sampled across habitat transformation gradients according to the areal cover of agriculture, urban development and alien invasive vegetation within 100 and 500 m radii of each wetland edge. We hypothesized that the principal drivers of physico-chemical conditions in these wetlands (e.g. soil properties, basin morphology are altered by habitat transformation. Multivariate multiple regression analyses (distance-based Redundancy Analysis indicated significant associations between wetland physico-chemistry and habitat transformation (overall transformation within 100 and 500 m, alien vegetation cover within 100 and 500 m, urban cover within 100 m; although for significant regressions the amount of variation explained was very low (range: ∼2 to ∼5.5%, relative to that explained by purely spatio-temporal factors (range: ∼35.5 to ∼43%. The nature of the relationships between each type of transformation in the landscape and individual physico-chemical variables in wetlands were further explored with univariate multiple regressions. Results suggest that conservation of relatively narrow (∼100 m buffer strips around temporary wetlands is likely to be effective in the maintenance of natural conditions in terms of physico-chemical water quality.

  16. Temporary employment in Russia: why mostly men?

    Directory of Open Access Journals (Sweden)

    Tatiana Karabchuk

    2012-08-01

    Full Text Available The paper deals with temporary employment in the Russian labour market. The main focus is the gender difference regarding determinants of temporary employment. Unlike most European countries, where women are more likely to have temporary work, in Russia men predominantly have this status, comparable to the situation in many developing countries. This paper seeks to understand why this is the case. The household survey of NOBUS (held in 2003 by State Statistical Centre with World Bank participation is used to answer this question: the results suggest that gender differences in temporary employment do exist, and that the main factors that explain these differences are education, and marital status.

  17. Transcatheter closure of membranous ventricular septal defects with home-made nitinol occluder

    Energy Technology Data Exchange (ETDEWEB)

    Yongwen, Qin; Xianxian, Zhao; Xing, Zheng; Jijun, Ding; Jiang, Cao [Second Military Medical Univ., Shanghai (China). Changhai Hospital, Dept. of Cardiology

    2004-04-01

    Objective: To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder. Methods: Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94 {+-} 2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92 {+-} 1.44) mm. A 7-10 F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68 {+-} 2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6 and 12 months of follow-up. Results: The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time

  18. 19 CFR 210.52 - Motions for temporary relief.

    Science.gov (United States)

    2010-04-01

    ....52 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Temporary Relief § 210.52 Motions for temporary relief... issuance of temporary relief, the Commission will be guided by practice under Rule 65 of the Federal Rules...

  19. Temporary Termination.

    Science.gov (United States)

    Seligman, Linda

    1984-01-01

    Presents a method for helping clients deal productively with temporary intervals in counseling relationships that may be caused by either counselor or client vacations or trips. Advocates developing goals, providing an opportunity for continued communication, referrals, processing of accomplishments, and scheduling the next session. (LLL)

  20. Temporary endoscopic metallic stent for idiopathic esophageal achalasia.

    Science.gov (United States)

    Coppola, Franco; Gaia, Silvia; Rolle, Emanuela; Recchia, Serafino

    2014-02-01

    Idiopathic achalasia is a motor disorder of the esophagus of unknown etiology caused by loss of motor neurons determining an altered motility. It may determine severe symptoms such as progressive dysphagia, regurgitations, and pulmonary aspirations. Many therapeutic options may be offered to patients with achalasia, from surgery to endoscopic treatments such as pneumatic dilation, botulinum injection, peroral endoscopic myotomy, or endoscopic stenting. Recently, temporary placement of a stent was proposed by Cheng as therapy for achalasia disorders, whereas no Western authors have dealt with it up to date. The present study reports our preliminary experience in 7 patients with achalasia treated with a temporary stent. Partially covered self-expanding metallic stents (Micro-Tech, Nanjin, China) 80 mm long and 30 mm wide were placed under fluoroscopic control and removed after 6 days. Clinical follow-up was scheduled to check endoscopic success, symptoms release, and complications. The placement and the removal of the stents were obtained in all patients without complications. Mean clinical follow-up was 19 months. Five out of 7 patients referred total symptoms release and 2 experienced significant improvement of dysphagia. The procedure was not time consuming and was safe; no mild or severe complications were registered. In conclusion, our results may suggest a possible safe and effective endoscopic alternative treatment in patients with achalasia; however, further larger studies are necessary to confirm these promising, but very preliminary, data.

  1. Diversity patterns of temporary wetland macroinvertebrate ...

    African Journals Online (AJOL)

    Although macroinvertebrates are potentially useful for assessing the condition of temporary wetlands, little is yet known about them. Macroinvertebrate assemblages were assessed in 138 temporary wetlands in the south-western Cape, recording 126 taxa. However, predicted richness estimates were all higher than the ...

  2. PC based temporary shielding administrative procedure (TSAP)

    International Nuclear Information System (INIS)

    Olsen, D.E.; Pederson, G.E.; Hamby, P.N.

    1995-01-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison's six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met

  3. PC based temporary shielding administrative procedure (TSAP)

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.E.; Pederson, G.E. [Sargent & Lundy, Chicago, IL (United States); Hamby, P.N. [Commonwealth Edison Co., Downers Grove, IL (United States)

    1995-03-01

    A completely new Administrative Procedure for temporary shielding was developed for use at Commonwealth Edison`s six nuclear stations. This procedure promotes the use of shielding, and addresses industry requirements for the use and control of temporary shielding. The importance of an effective procedure has increased since more temporary shielding is being used as ALARA goals become more ambitious. To help implement the administrative procedure, a personal computer software program was written to incorporate the procedural requirements. This software incorporates the useability of a Windows graphical user interface with extensive help and database features. This combination of a comprehensive administrative procedure and user friendly software promotes the effective use and management of temporary shielding while ensuring that industry requirements are met.

  4. 36 CFR 13.166 - Temporary facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Temporary facilities. 13.166... facilities. A temporary facility or structure directly and necessarily related to the taking of subsistence... facilities which shall be published annually in accordance with § 1.7 of this chapter. ...

  5. Temporary air-raid shelters

    International Nuclear Information System (INIS)

    Jokela, J.; Olin, J.; Koukkari, H.

    1983-05-01

    This report deals with materials and structures of temporary air-raid shelters. At first, the weapon effects against which the temporary shelters can protect are described. These are, primarily, the fragmentation and blast pressure caused by conventional weapons and those effects of the nuclear weapons which exist outside the total disaster and fire areas. Temporary shelters built into existing buildings can give protection either from radioactive fallout or from fallout and collapse of the building above. For fallout protection heavy materials are needed, which simultaneously protect from fragmentation. In the research report, the methods and materials used for the contruction of a fallout shelter into an apartment house and a small house are introduced. The collapse loads acting on a basement ceiling and the design of additional timber supports are also presented. The use of various materials in the construction of shelters outside the buildings are introduced. Separate shelters can be built either under the ground or on the ground. The same materials can be used in both cases, but the underground shelters have a better level of protection. (author)

  6. 21 CFR 870.3680 - Cardiovascular permanent or temporary pacemaker electrode.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiovascular permanent or temporary pacemaker... § 870.3680 Cardiovascular permanent or temporary pacemaker electrode. (a) Temporary pacemaker electrode—(1) Identification. A temporary pacemaker electrode is a device consisting of flexible insulated...

  7. 48 CFR 37.112 - Government use of private sector temporaries.

    Science.gov (United States)

    2010-10-01

    ... use of private sector temporaries. Contracting officers may enter into contracts with temporary help service firms for the brief or intermittent use of the skills of private sector temporaries. Services... part 300, subpart E, Use of Private Sector Temporaries, and agency procedures. [56 FR 55380, Oct. 25...

  8. Temporary storage area characterization report

    International Nuclear Information System (INIS)

    1990-01-01

    The preferred alternative identified in the Remedial Investigation/Feasibility Study (RI/FS) for the Weldon Spring Quarry Bulk Wastes is to remove the wastes from the quarry and transport them by truck to temporary storage facility at the chemical plant site. To support the RI/FS, this report provides data to characterize the temporary storage area (TSA) site and to ensure the suitability of the proposed location. 31 refs., 14 figs., 7 tabs

  9. Evaluation of separation distance from the temporary storage facility for decontamination waste to ensure public radiological safety after Fukushima nuclear power plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Jung; Go, A Ra; Kim, Kwang Pyo [Kyung Hee University, Yongin (Korea, Republic of)

    2016-09-15

    The object of this study was to evaluate the separation distance from a temporary storage facility satisfying the dose criteria. The calculation of ambient dose rates took into account cover soil thickness, facility size, and facility type by using MCNPX code. Shielding effects of cover soil were 68.9%, 96.9% and 99.7% at 10 cm, 30 cm and 50 cm respectively. The on-ground type of storage facility had the highest ambient dose rate, followed by the semi-ground type and the underground type. The ambient dose rate did not vary with facility size (except 5 × 5 × 2 m size) due to the self-shielding of decontamination waste in temporary storage. The separation distances without cover soil for a 50 × 50 × 2 m size facility were evaluated as 14 m (minimum radioactivity concentration), 33 m (most probably radioactivity concentration), and 57 m (maximum radioactivity concentration) for on-ground storage type, 9 m, 24 m, and 45 m for semi-underground storage type, and 6 m, 16 m, and 31 m for underground storage type.

  10. 76 FR 37147 - Notice of Temporary Closures and Temporary Restrictions on Specific Uses of Public Lands in...

    Science.gov (United States)

    2011-06-24

    ... days a week, to leave a message or question with the above individual. You will receive a reply during... provide additional law enforcement officers to work at the event. These temporary closures and temporary... authorized officer. 4. Definitions: (a) Weapon means a firearm, compressed gas or spring powered pistol or...

  11. Insertion of Self-Expandable Nitinol Stents Without Previous Balloon Angioplasty Reduces Restenosis Compared with PTA Prior to Stenting

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Stenram, Unne; Cwikiel, Wojciech

    2002-01-01

    Purpose: To compare the development of intimal hyperplasia after deployment of a self-expanding nitinol stent with and without previous percutaneous transluminal balloon angioplasty (PTA), with the results after PTA alone. Methods: In nine healthy pigs, the iliac arteries were divided into three groups: group 1 (n = 6 arteries) was treated with PTA; group 2 n 6)with insertion of self-expanding stents after PTA; and group 3 (n = 6) with stent insertion without previous PTA. After 8 weeks the vessels were examined with intravascular ultrasonography,histologic examination and morphometric analysis. Results: Although the injury index in group 1 (0.17± 0.57) was lower (p <0.05) than in group 2 (0.26 ± 0.06) and group 3 (0.26 ± 0.08), PTA-treated arteries showed significantly (p <0.05) reduced mean luminal gain (0.53 ± 2.84) compared with arteries treated with PTA prior to stenting (2.58 ± 1.38) and compared with stenting alone (4.65 ±5.34). Stenting after PTA resulted in a higher (p<0.05) restenosis index (2.63 ± 1.06) compared with stenting without PTA (1.35 ± 0.59). Group 2 also had a significantly thicker intimap <0.05) and 83% and 74% higher intima/mediaratio (p <0.05) compared with groups 1 and 3, respectively. Conclusion: Insertion of a self-expandable nitinol stent without previous PTA results in less intimalhyperplasia than if PTA is performed prior to stenting, suggesting that direct stenting can be used in angioplasty sessions with a favorable outcome

  12. Mechanical stability of the diamond-like carbon film on nitinol vascular stents under cyclic loading

    International Nuclear Information System (INIS)

    Kim, Hyun-Jong; Moon, Myoung-Woon; Lee, Kwang-Ryeol; Seok, Hyun-Kwang; Han, Seung-Hee; Ryu, Jae-Woo; Shin, Kyong-Min; Oh, Kyu Hwan

    2008-01-01

    The mechanical stability of diamond-like carbon (DLC) films coated on nitinol vascular stents was investigated under cyclic loading condition by employing a stent crimping system. DLC films were coated on the vascular stent of a three dimensional structure by using a hybrid ion beam system with rotating jig. The cracking or delamination of the DLC coating occurred dominantly near the hinge connecting the V-shaped segments of the stent where the maximum strain was induced by a cyclic loading of contraction and extension. However the failures were significantly suppressed as the amorphous Si (a-Si) buffer layer thickness increased. Interfacial adhesion strength was estimated from the spalled crack size in the DLC coating for various values of the a-Si buffer layer thickness

  13. Initial and mid-term results of a 4F compatible self-expanding low strut profile nitinol stent in the superficial femoral artery

    International Nuclear Information System (INIS)

    Muehlenbruch, G.; Brock, H.; Das, M.; Hohl, C.; Mahnken, A.H.; Wildberger, J.; Guenther, R.W.; Haage, P.

    2007-01-01

    Purpose: To evaluate the initial and mid-term results of a new self-expanding low strut profile nitinol stent for treatment of atherosclerotic lesions stenoses and occlusions in the superficial femoral artery (SFA). Materials and Methods: In 8 patients (4 male, 4 female, mean age 74.8 ± 8.8 years) with SFA lesions and non-satisfying results after PTA treatment alone, 10 self-expanding nitinol Xpert stents were deployed via a 4 F sheath. Stent characteristics and handling were graded by the interventionalist. Fontaine classification, duplex flow measurements and ankle brachial index (ABI) at rest and stress were taken prior and one day after stent placement. Patients were followed 3, 6 and 12 months after the procedure obtaining the same parameters at each appointment. Results: Initial stent treatment was successful in all patients. Stent handling and positioning were rated very good and safe. All patients improved clinically by at least one Fontaine stage (range before treatment: stage IIb to IV). The mean ABI at rest (stress) improved initially from 0.68 (0.70) to 1.07 (0.99). During a mean follow-up period of 8.3 months no case of clinically relevant in-stent stenosis was observed with stable values of ABI at rest and stress. (orig.)

  14. Study of critical dependence of stable phases in Nitinol on heat treatment using electrical resistivity probe

    International Nuclear Information System (INIS)

    Uchil, J.; Mohanchandra, K.P.; Kumara, K.G.; Mahesh, K.K.

    1998-01-01

    Phase transformations in 40% cold-worked Nitinol as a function of heat treatment have been studied using electrical resistivity variation with temperature. The stabilisation of austenitic, rhombohedral and martensitic phases is shown to critically depend on the temperatures of heat treatment by the analysis of temperature dependence of electrical resistivity in heating and cooling parts of the cycle. Characteristic values of electrical resistivity of the stable phases are determined. The R-phase has been found to form continuously with increasing heat-treatment temperature starting from room temperature and to suddenly disappear beyond heat-treatment at 683 K. The observed presence or absence of R-phase is confirmed by heat capacity measurements as a function of temperature. (orig.)

  15. [Temporary disability and its legal implications].

    Science.gov (United States)

    Martin-Fumadó, Carles; Martí Amengual, Gabriel; Puig Bausili, Lluïsa; Arimany-Manso, Josep

    2014-03-01

    Temporary disability is the condition that workers face when, as the result of illness (common or professional) or accident (work-related or not), they are temporarily prevented from performing their work and require health care. The management of temporary disability is a medical act that involves (in addition to a complex clinical assessment) obvious social, occupational and financial connotations and requires continuing medical follow-up from doctors, as well as responses to medical-legal conflicts. The regulatory framework on the subject is extensive in the Spanish setting and highly diverse in the European setting. Beyond the regulatory framework, the repercussions of temporary disability are self-evident at all levels. Although determining temporary disability is a common medical act for practicing physicians, it is not exempt from risks or difficulties arising from the assessment itself and the characteristics of practicing medical care. Established medical-legal conflicts include the processing of health data and the requirements for transferring information related to workers' temporary disability to their company's medical services. The interest and usefulness demonstrated by the data obtained from forensic medicine for public health require the incorporation of these data into general healthcare information, as it could be essential to the surveillance of worker health. The recommendations established by medical societies, as good practice guidelines, are especially useful in this type of conflict. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  16. Transcatheter closure of membranous ventricular septal defects with home-made nitinol occluder

    International Nuclear Information System (INIS)

    Qin Yongwen; Zhao Xianxian; Zheng Xing; Ding Jijun; Cao Jiang

    2004-01-01

    Objective: To evaluate the feasibility and efficacy of transcatheter perimembranous ventricular septal defects (VSD) occlusion with home-made nitinol occluder. Methods: Transcatheter closure was attempted in 196 patients with perimembranous VSD. The diameter of VSD measured by echocardiography was 3 to 15 mm, mean (4.94 ± 2.23) mm. The angiographic diameter of the VSD was 3 to 6 mm, mean (3.92 ± 1.44) mm. A 7-10 F delivery sheath was advanced across the perimembranous VSD over a wire from femoral vein to deploy the occluder with the guidance of echocardiography and fluoroscopy. The device diameter selected was from 4 to 20 mm, mean (6.68 ± 2.76) mm. Left ventriculography and transthoracic echocardiography were repeated to assess the closure of the defects 15 min after the procedure. Continuous electrocardiogram monitoring lasted for 5 days. The echocardiography and electrocardiogram examination were scheduled for 1, 6 and 12 months of follow-up. Results: The occluders were successfully deployed in 191 patients. There were five procedural failures, two with device-related aortic insufficiency, and three of inability to pass through VSD. After deployment of the devices, there were no residual shunt in 180 of 191 patients, 11 patients with a trivial residual shunt that disappeared in 8 patients after one month of follow up. 3 patients developed mild tricuspid insufficiency. 12 developed transient complete right bundle branch block, and 5 transient complete left bundle branch block, and 2 transient complete atrioventricular block. There were repetitive nonparoxysmal ventricular tachycardia in 4 patients 1 week after the procedure. One patient had a detached device embolized into the left pulmonary artery but with a successful catheter retrieval by snare and transcatheter closure. The devices were similarly applied to patients with VSD associated with patent ductus arteriosus, and 4 patients with VSD complicated by atrial septal defects. The fluoroscopy time for the

  17. 77 FR 15650 - Fisher House and Other Temporary Lodging

    Science.gov (United States)

    2012-03-16

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 60 RIN 2900-AN79 Fisher House and Other Temporary... Affairs (VA) proposes to amend its regulations concerning Fisher House and other temporary lodging... assistance and clarify the distinctions between Fisher House and other temporary lodging provided by VA. The...

  18. Protection against productivity versus erosion vineyards. Testing of vegetal covers in slope crops; Proteccion contra la erosion versus productividad en venidos. Ensayos de cubiertas vegetales en cultivos en pendiente

    Energy Technology Data Exchange (ETDEWEB)

    Marques, M. J.; Ruiz-Colmenero, M.; Garcia-Munoz, S.; Cabello, F.; Munoz-Organero, G.; Perez-Jimenez, M. A.; Bienes, R.

    2009-07-01

    Temporary and permanent cover crops were used in three rain fed vineyards in the Center of Spain. They were sown in the middle of the strips to assess their ability to control erosion as well as their influence on grape production. Data from the year 2008 are compared with those obtained with traditional tillage treatment. The permanent cover formed by Brachypodium distachyon showed better ability to control erosion but it produced a decrease in production in young vines. barley and rye treatments were temporary covers, mowed in spring. They also reduced the erosion compared with the tillage however they did not appear to affect the vineyard production. (Author)

  19. Temporary Employment and the Future Labor Market Status

    Directory of Open Access Journals (Sweden)

    Tomas Berglund

    2017-06-01

    Full Text Available The aim of this article is to describe and explain the development of temporary employment in Sweden between 1992 and 2010, and to investigate the effect of temporary employment for individuals’ future career on the labor market. The article analyzes temporary employees’ status transitions on the labor market using Swedish Labour Force Survey (LFS data for the period 1992–2010. Each cohort consists of 2-year panels and focuses on changes between the first and last measuring points. The findings indicate that the specific type of temporary employment is crucial as regards whether or not it constitutes a stepping-stone toward permanent employment. The chances are greater in the case of, for example, substitutes, but are considerably less in the case of on-call employment. Certain types of temporary employment thus seem to be used by the employer to screen the employability of the employee, while others are used for achieving flexibility

  20. Temporary Employment and Perceived Employability: Mediation by Impression Management

    Science.gov (United States)

    De Cuyper, Nele; De Witte, Hans

    2010-01-01

    Perceived employability (PE) has been advanced as the upcoming resource for career development, particularly for temporary workers. The question is how temporary workers become employable. Our hypothesis is that temporary workers more than permanent workers use impression management to become employable, both on the internal and the external labor…

  1. Covering techniques for severe burn treatment: lessons for radiological burn accidents

    International Nuclear Information System (INIS)

    Carsin, H.; Stephanazzi, J.; Lambert, F.; Curet, P.M.; Gourmelon, P.

    2002-01-01

    Covering techniques for severe burn treatment: lessons for radiological burn accidents. After a severe burn, the injured person is weakened by a risk of infection and a general inflammation. The necrotic tissues have to be removed because they are toxic for the organism. The injured person also needs to be covered by a cutaneous envelope, which has to be done by a treatment centre for burned people. The different techniques are the following: - auto grafts on limited burned areas; - cutaneous substitutes to cover temporary extended burned areas. Among them: natural substitutes like xenografts (pork skin, sheep skin,..) or allografts (human skin), - treated natural substitutes which only maintain the extracellular matrix. Artificial skins belong to this category and allow the development of high quality scars, - cell cultures in the laboratory: multiplying the individual cells and grafting them onto the patient. This technique is not common but allows one to heal severely injured patients. X-ray burns are still a problem. Their characteristics are analysed: intensive, permanent, antalgic resistant pain. They are difficult to compare with heat burns. In spite of a small number of known cases, we can give some comments and guidance on radio necrosis cures: the importance of the patients comfort, of ending the pain, of preventing infection, and nutritional balance. At the level of epidermic inflammation and phlyctena (skin blisters), the treatment may be completed by the use of growth factors. At the level of necrosis, after a temporary cover, an auto graft can be considered only if a healthy basis is guaranteed. The use of cellular cultures in order to obtain harmonious growth factors can be argued. (author)

  2. 46 CFR 112.01-15 - Temporary emergency power source.

    Science.gov (United States)

    2010-10-01

    ... EMERGENCY LIGHTING AND POWER SYSTEMS Definitions of Emergency Lighting and Power Systems § 112.01-15 Temporary emergency power source. A temporary emergency power source is one of limited capacity that carries... 46 Shipping 4 2010-10-01 2010-10-01 false Temporary emergency power source. 112.01-15 Section 112...

  3. Passive base isolation with superelastic nitinol SMA helical springs

    International Nuclear Information System (INIS)

    Huang, Bin; Zhang, Haiyang; Wang, Han; Song, Gangbing

    2014-01-01

    Seismic isolation of structures such as multi-story buildings, nuclear reactors, bridges, and liquid storage tanks should be designed to preserve structural integrity. By implementing seismic isolation technology, the deformation of superstructures can be dramatically reduced, consequently helping to protect their safety as well. In this paper, an innovative type of passive base isolation system, which is mainly composed of superelastic nitinol SMA helical springs, is developed. In order to verify the effectiveness of the proposed system, a two-story experimental steel frame model is constructed, and two superelastic SMA helical springs are thermo-mechanically built in the laboratory. To describe the nonlinear mechanical properties of the superelastic SMA helical springs under reciprocating load, a phenomenological model is presented in terms of a series of tensile tests. Afterwards, a numerical model of the two-story frame with the suggested isolation system is set up to simulate the response of the isolated frame subjected to an earthquake. Both the experimental and the numerical simulation results indicate that the proposed base isolation system can remarkably suppress structural vibrations and has improved isolation effects when compared with a steel spring isolation system. Due to the capabilities of energy dissipation as well as fully re-centering, it is very applicable to utilize the suggested isolation system in base isolated structures to resist earthquakes. (paper)

  4. Silver deposition on polypyrrole films electrosynthesised onto Nitinol alloy. Corrosion protection and antibacterial activity.

    Science.gov (United States)

    Saugo, M; Flamini, D O; Brugnoni, L I; Saidman, S B

    2015-11-01

    The electrosynthesis of polypyrrole films onto Nitinol from sodium salicylate solutions of different concentrations is reported. The morphology and corrosion protection properties of the resulting coatings were examined and they both depend on the sodium salicylate concentration. The immobilisation of silver species in PPy films constituted by hollow rectangular microtubes was studied as a function of the polymer oxidation degree. The highest amount of silver was deposited when the coated electrode was prepolarised at -1.00V (SCE) before silver deposition, suggesting an increase in the amount of non-oxidised segments in the polymer. Finally, the antibacterial activity of the coating against the Gram positive Staphylococcus aureus and Staphylococcus epidermidis bacteria was evaluated. Both strains resulted sensitive to the modified coatings, obtaining a slightly better result against S. aureus. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. 19 CFR 210.77 - Temporary emergency action.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Temporary emergency action. 210.77 Section 210.77 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Enforcement Procedures and Advisory Opinions § 210.77 Temporary...

  6. Morbidity with temporary disability in Kozloduy NPP workers

    International Nuclear Information System (INIS)

    Dobreva, B.; Novkirishki, V.

    1993-01-01

    Changes with time in indicators of disease incidence with temporary disability in Kozloduy NPP personnel have been studied for the period 1974-1991. The data were compared with those for 'Sofia-Iztok' TPP. The causes contributing to formation of the indicators of frequency, severity, and average duration were examined. No temporary disability because of radiation exposure has been recorded. As a whole, less temporary disability has been found at NPP than at TPP. (author)

  7. Temporary jobs and the severity of workplace accidents.

    Science.gov (United States)

    Picchio, Matteo; van Ours, Jan C

    2017-06-01

    From the point of view of workplace safety, it is important to know whether having a temporary job has an effect on the severity of workplace accidents. We present an empirical analysis on the severity of workplace accidents by type of contract. We used microdata collected by the Italian national institute managing the mandatory insurance against work related accidents. We estimated linear models for a measure of the severity of the workplace accident. We controlled for time-invariant fixed effects at worker and firm levels to disentangle the impact of the type of contract from the spurious one induced by unobservables at worker and firm levels. Workers with a temporary contract, if subject to a workplace accident, were more likely to be confronted with severe injuries than permanent workers. When correcting the statistical analysis for injury under-reporting of temporary workers, we found that most of, but not all, the effect is driven by the under-reporting bias. The effect of temporary contracts on the injury severity survived the inclusion of worker and firm fixed effects and the correction for temporary workers' injury under-reporting. This, however, does not exclude the possibility that, within firms, the nature of the work may vary between different categories of workers. For example, temporary workers might be more likely to be assigned dangerous tasks because they might have less bargaining power. The findings will help in designing public policy effective in increasing temporary workers' safety at work and limiting their injury under-reporting. Copyright © 2017. Published by Elsevier Ltd.

  8. Permanent and temporary pacemaker implantation after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Bacal Fernando

    2000-01-01

    Full Text Available PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%heart transplant recipients required temporary pacing and 4 of 114 (3.5% patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5% and atrioventricular (AV block in 3 patients (21.4%. The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75% and atrioventricular (AV block in 1 patient (25%. We observed rejection in 3 patients (21.4% who required temporary pacing and in 2 patients (50% who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4% with temporary pacing. Seven of the 14 patients (50% died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

  9. 21 CFR 872.3770 - Temporary crown and bridge resin.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Temporary crown and bridge resin. 872.3770 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3770 Temporary crown and bridge resin. (a) Identification. A temporary crown and bridge resin is a device composed of a material, such as...

  10. 78 FR 44965 - Notice of Temporary Closure and Temporary Restrictions of Specific Uses on Public Lands for the...

    Science.gov (United States)

    2013-07-25

    ... individual during normal business hours. The FIRS is available 24 hours a day, 7 days a week, to leave a... provide law enforcement officers to work at the event. The temporary closure and temporary restrictions...) Weapon means a firearm, compressed gas or spring powered pistol or rifle, bow and arrow, cross bow...

  11. Return to Work After Temporary Disability Pension in Finland.

    Science.gov (United States)

    Laaksonen, Mikko; Gould, Raija

    2015-09-01

    When it is possible that the employee's work ability can be restored through treatment or rehabilitation, disability pension in Finland is granted for a fixed period. We examined which factors are associated with return to work (RTW) after such temporary disability pension. The study included all Finnish residents whose temporary disability pension from the earnings-related pension system started in 2008 (N = 10,269). Competing risks regression analysis was applied to examine register-based determinants for RTW after temporary disability pension due to mental disorders, musculoskeletal diseases, other diseases, and injury over a 4-year follow-up period. The overall cumulative incidence of RTW was 25%. RTW was more probable after temporary disability pension due to injury and musculoskeletal diseases and less probable after temporary disability pension due to mental disorders. Younger age and higher education increased RTW but differences between genders, private and public sector employees, and occupational classes were relatively small. The probability of RTW was higher among those who were employed before their temporary disability pension (subhazard ratio in multivariate analysis 2.41 (95% CI 2.13-2.72) and among the 9% who participated in vocational rehabilitation during their pension [SHR 2.10 (95% CI 1.90-2.31)]. With some exceptions, the results were fairly similar for all diagnostic causes of temporary disability pension. Return to work after temporary disability pension was relatively uncommon. Nevertheless, in all diagnostic groups RTW continued for the whole follow-up period. The low educated and those not employed before temporary disability pension need more support in their RTW. The strong association between vocational rehabilitation and RTW suggests that increasing rehabilitation among those with impaired work ability may promote RTW.

  12. Connecting Temporary and Permanent Organizing

    DEFF Research Database (Denmark)

    Stjerne, Iben Sandal; Velikova, Silviya Svejenova

    2016-01-01

    This paper investigates the relationship between a permanent organization and a series of temporary organizations. It draws on an in-depth study of the process through which a Danish film production company, seeking to balance innovation and persistence in a troubled industry, struggles to realize...... a novel children’s film and its sequels. The study reveals tensions at different levels as well as boundary work and boundary roles that address them, bringing in shadows of past and future projects. The study extends the understanding of the dialectic between temporary and permanent organizing...

  13. On the Sharing of Temporary Parental Leave

    DEFF Research Database (Denmark)

    Amilon, Anna

    2007-01-01

    This paper views temporary parental leave (leave from work to take care of a sick child) as a household public good, produced with time inputs of the parents as the only input. Assuming equal productivities in the production of temporary parental leave and equal utility functions of the spouses...

  14. 17 CFR 256.136 - Temporary cash investments.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Temporary cash investments... UTILITY HOLDING COMPANY ACT OF 1935 3. Current and Accrued Assets § 256.136 Temporary cash investments. This account shall include the cost of investments, such as demand and time loans, bankers' acceptances...

  15. Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

    International Nuclear Information System (INIS)

    Bent, Clare L.; Low, Deborah; Matson, Matthew B.; Renfrew, Ian; Fotheringham, Tim

    2009-01-01

    The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 ± 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 ± 2.5 min. Mean absolute increase in FLR volume was 68.9% ± 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

  16. Green superlubricity of Nitinol 60 alloy against steel in presence of castor oil

    Science.gov (United States)

    Zeng, Qunfeng; Dong, Guangneng; Martin, Jean Michel

    2016-07-01

    In the present work, first, we show that sliding Nitinol 60 alloy against steel under castor oil lubrication exhibits a new case of superlubricity (coefficient of friction CoF ≪ 0.01). So far, CoF below 0.01 have never been achieved under boundary lubrication at high contact pressure and in presence of vegetable oil as a green lubricant. Next, it is demonstrated that superlubricity is controlled by tribochemical reactions, involving chemical degradation of castor oil and the formation of metal oxy-hydroxides. Finally, to explain these findings, we propose a novel superlubricity mechanism consisting of hexanoic acid molecules intercalated between nickel and iron oxy-hydroxide lamellar layers, a structure very similar to the one found in Fe-Ni batteries. We propose that superlubricity is achieved due to repulsive electrostatic forces acting between the intercalated metal oxy-hydroxide lamellar compounds. This system would be suitable for practical engineering applications in many fields including biotechnologies.

  17. Simon nitinol vena cava filters: effectiveness and complications

    International Nuclear Information System (INIS)

    Wolf, F.; Thurnher, S.; Lammer, J.

    2001-01-01

    Purpose: The aim of this retrospective analysis was to evaluate the clinical safety and effectiveness of the simon nitinol inferior vena cava filter (SNF) for prevention of pulmonary embolism. Patients and Methods: 117 patients (63 male, 54 female; aged 58.38 ± 14.59 years) underwent percutaneous implantation of an SNF from 1993 through 1999. Patient reports were retrospectively analysed for complications during and after implantation and deep venous thrombosis (DVT) and pulmonary embolism before and after implantation. Helical-CT with contrast media and plain abdominal radiography were performed on 35 patients, helical-CT alone on two patients. We checked the position and configuration of the SNF and looked for a perforation of the filter legs through the wall of the inferior vena cava (IVC). The IVC and deep pelvic veins were analysed for patency. Results: During implantation 10 of 117 (9%) patients had minor complications, major complications were reported in 0.9% (1/117). There was no significant increase in thrombosis of the deep pelvic veins and the IVC after implantation. Pulmonary re-embolism (PE) was documented in 9 out of 117 patients (7.7%). One out of the 35 examined patients (2.9%) showed a single strut fracture of the SNF. Tilting more than 15 was seen in 7 out of 37 patients (19%). Dislocation of the SNF more than 10 mm occurred in one out of 35 patients (2.9%), perforation through the wall of the IVC in all 37 patients. We found no occlusion of the IVC. (orig.) [de

  18. 29 CFR 1926.154 - Temporary heating devices.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Temporary heating devices. 1926.154 Section 1926.154 Labor... Temporary heating devices. (a) Ventilation. (1) Fresh air shall be supplied in sufficient quantities to... heating devices shall be installed to provide clearance to combustible material not less than the amount...

  19. Screening for common mental disorders and substance abuse among temporary hired cleaners in Egyptian Governmental Hospitals, Zagazig City, Sharqia Governorate.

    Science.gov (United States)

    Abbas, R A; Hammam, R A M; El-Gohary, S S; Sabik, L M E; Hunter, M S

    2013-01-01

    Informal employment is common in developing countries, including Egypt. This type of employment may have significant consequences on mental health. To determine the prevalence and risk factors of common mental disorders and substance abuse among temporary hired hospital cleaners. A cross-sectional study was conducted on 242 adult temporary cleaners and 209 permanent cleaners working in 4 governmental hospitals in Zagazig City, Sharqia Governorate, Egypt. All participants were invited to complete a structured questionnaire through a semi-structured interview which included the self-reporting questionnaire 20 items (SRQ-20) and the work stress scale. Assessment of drug use included urine-based screening tests for common substances abused. The prevalence of job stress, common mental disorders and substance abuse, particularly tramadol and cannabis (Bango), was significantly higher in the studied temporary cleaners compared to permanent cleaners. Risk factors associated with increased susceptibility of the temporary cleaners to common mental disorders were family history of substance abuse, high crowding index, history of physical illness, low educational level, and smoking; while being unmarried, male sex, family history of mental disorder, age ≥40 years, smoking, and length of service ≥8 years, were associated with substance abuse among the same group. Temporary hired hospital cleaners suffered from impaired mental health more than permanent cleaners. Therefore, expanding the coverage of current laws and occupational safety and health standards to cover workers in the informal sector especially in developing countries is recommended.

  20. Screening for Common Mental Disorders and Substance Abuse among Temporary Hired Cleaners in Egyptian Governmental Hospitals, Zagazig City, Sharqia Governorate

    Directory of Open Access Journals (Sweden)

    RA Abbas

    2012-12-01

    Full Text Available Background: Informal employment is common in developing countries, including Egypt. This type of employment may have significant consequences on mental health. Objectives: To determine the prevalence and risk factors of common mental disorders and substance abuse among temporary hired hospital cleaners. Methods: A cross-sectional study was conducted on 242 adult temporary cleaners and 209 permanent cleaners working in 4 governmental hospitals in Zagazig City, Sharqia Governorate, Egypt. All participants were invited to complete a structured questionnaire through a semi-structured interview which included the self-reporting questionnaire 20 items (SRQ-20 and the work stress scale. Assessment of drug use included urine-based screening tests for common substances abused. Results: The prevalence of job stress, common mental disorders and substance abuse, particularly tramadol and cannabis (Bango, was significantly higher in the studied temporary cleaners compared to permanent cleaners. Risk factors associated with increased susceptibility of the temporary cleaners to common mental disorders were family history of substance abuse, high crowding index, history of physical illness, low educational level, and smoking; while being unmarried, male sex, family history of mental disorder, age ≥40 years, smoking, and length of service ≥8 years, were associated with substance abuse among the same group. Conclusion: Temporary hired hospital cleaners suffered from impaired mental health more than permanent cleaners. Therefore, expanding the coverage of current laws and occupational safety and health standards to cover workers in the informal sector especially in developing countries is recommended.

  1. Regenerating 'Østre Havn' - The Everyday of Temporary Use Strategies

    DEFF Research Database (Denmark)

    Olsen, Tina Vestermann; Mikkelsen, Jacob Bjerre

    2015-01-01

    The article taps into discussions on temporary uses as a place-producing and transformative tool. At ‘Østre Havn’, a former industrial harbour in Aalborg, on-going developments strive for mixtures of residences, business and leisure. As tools towards that end the site is currently the test bed...... for a wide range of temporary uses. These are taking place alongside construction activities. This sets boundaries for the temporary use activities while the proposed future outlined by the municipality and the developer is being established. The question is what happens at the level of the everyday, how...... is the temporary use strategy affecting and shaping the opportunities for the group of temporary use activists to create difference at the site? The article aims at answering this by depicting a real life process over a timespan of two years - mainly from the perspective of the group of temporary use activists...

  2. Lessons learnt from experimental temporary octopus fishing ...

    African Journals Online (AJOL)

    This paper presents evidence of the fisheries effect of experimental temporary fishing closures for Octopus in the then-emergent Velondriake Locally Managed Marine Area (LMMA) in south-west Madagascar during 2004–2006. We present an analysis of the O. cyanea catch data for the first two years of temporary closures ...

  3. Temporary labour contracts

    CERN Document Server

    2001-01-01

    At its September 2000 meeting, the Finance Committee approved a second one-year extension of the four existing temporary labour contracts (L020/PE, L021/PE, L022/PE, L023/PE) until 31 December 2001 for a total amount not exceeding 6 000 000 Swiss francs at 2000 prices. The Finance Committee is invited: - to take note that the estimated annual expenditure on temporary labour in 2001 will amount to approximately 4 500 000 Swiss francs against the previously estimated 6 000 000 Swiss francs; - to approve the extension of the four existing contracts by six months to 30 June 2002 for an overall amount not exceeding 1 500 000 Swiss francs; - to take note that new contracts for the Swiss part of the CERN site will be submitted for adjudication in December 2001 and that new contracts for the French part of the CERN site will be submitted for adjudication in the course of 2002.

  4. [Evaluation of pollution of an urban area by level of heavy metals in snow cover].

    Science.gov (United States)

    Stepanova, N V; Khamitova, R Ia; Petrova, R S

    2003-01-01

    The goal of this study was to systematize various methodological approaches to evaluating the contamination of the snow cover with heavy metals (HM) by using Kazan, an industrial city with diversified industry, as an example. The findings suggest that it is necessary to characterize the contamination of the snow cover by the actual entrance of an element per area unit of the snow cover for a definite period of time rather than by the concentration of TM in the volume unit of snow water (mg/l), which minimizes the uncertainties with spatial and temporary snow cover variations. The index of the maximum allowable entrance, which is of practical value, may be used to objectively calibrate the pollution of the snow cover, by estimating the amount of a coming element and its toxicity.

  5. Long-Term Primary Patency Rate After Nitinol Self-Expandable Stents Implantation in Long, Totally Occluded Femoropopliteal (TASC II C & D) Lesions.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; Buonamici, Piergiovanni; Trapani, Maurizio; Valenti, Renato; Migliorini, Angela; Parodi, Guido; Antoniucci, David

    2017-06-01

    Endovascular therapy for long femoropopliteal lesions using percutaneous transluminal balloon angioplasty or first-generation of peripheral stents has been associated with unacceptable one-year restenosis rates. However, with recent advances in equipment and techniques, a better primary patency rate is expected. This study was conducted to detect the long-term primary patency rate of nitinol self-expandable stents implanted in long, totally occluded femoropopliteal lesions TransAtlantic Inter-Society Census (TASC II type C & D), and determine the predictors of reocclusion or restenosis in the stented segments. The demographics, clinical, anatomical, and procedural data of 213 patients with 240 de novo totally occluded femoropopliteal (TASC II type C & D) lesions treated with nitinol self-expandable stents were retrospectively analysed. Of these limbs, 159 (66.2%) presented with intermittent claudication, while 81 (33.8%) presented with critical limb ischaemia. The mean-time of follow-up was 36±22.6 months, (range: 6.3-106.2 months). Outcomes evaluated were, primary patency rate and predictors of reocclusion or restenosis in the stented segments. The mean age of the patients was 70.9±9.3 years, with male gender 66.2%. Mean pre-procedural ABI was 0.45±0.53. One-hundred-and-seventy-five (73%) lesions were TASC II type C, while 65 (27%) were type D lesions. The mean length of the lesions was 17.9±11.3mm. Procedure related complications occurred in 10 (4.1%) limbs. There was no periprocedural mortality. Reocclusion and restenosis were detected during follow-up in 45 and 30 limbs respectively, and all were re-treated by endovascular approach. None of the patients required major amputation. Primary patency rates were 81.4±1.1%, 77.7±1.9% and 74.4±2.8% at 12, 24, and 36 months respectively. Male gender, severe calcification, and TASC II D lesion were independent predictors for reocclusion, while predictors of restenosis were DM, smoking and TASC II D lesions

  6. 19 CFR 210.68 - Complainant's temporary relief bond.

    Science.gov (United States)

    2010-04-01

    ... Section 210.68 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Temporary Relief § 210.68 Complainant's temporary... by Individual Surety United States International Trade Commission Affidavit by Individual Surety 19...

  7. Early Closure of a Temporary Ileostomy in Patients With Rectal Cancer

    DEFF Research Database (Denmark)

    Danielsen, Anne K; Park, Jennifer; Jansen, Jens E

    2017-01-01

    OBJECTIVE: The objective was to study morbidity and mortality associated with early closure (8-13 days) of a temporary stoma compared with standard procedure (closure after > 12 weeks) after rectal resection for cancer. BACKGROUND: A temporary ileostomy may reduce the risk of pelvic sepsis after .......0001. CONCLUSIONS: It is safe to close a temporary ileostomy 8 to 13 days after rectal resection and anastomosis for rectal cancer in selected patients without clinical or radiological signs of anastomotic leakage.......OBJECTIVE: The objective was to study morbidity and mortality associated with early closure (8-13 days) of a temporary stoma compared with standard procedure (closure after > 12 weeks) after rectal resection for cancer. BACKGROUND: A temporary ileostomy may reduce the risk of pelvic sepsis after...... creation) of a temporary ileostomy was compared with late closure (>12 weeks) in a multicenter randomized controlled trial, EASY (www.clinicaltrials.gov, NCT01287637) including patients undergoing rectal resection for cancer. Patients with a temporary ileostomy without signs of postoperative complications...

  8. The EPIC nitinol stent system in the treatment of iliac artery lesions: one-year results from the ORION clinical trial.

    Science.gov (United States)

    Clair, Daniel G; Adams, Julie; Reen, Bernard; Feldman, Robert; Starr, Jean; Diaz-Cartelle, Juan; Dawkins, Keith D

    2014-04-01

    To report the 1-year results of a pivotal study for a new-generation nitinol stent for the treatment of iliac atherosclerotic lesions. The ORION trial (ClinicalTrials.gov identifier NCT00896337) was a single-arm, non-randomized, prospective, multicenter clinical trial that enrolled 125 patients (81 men; mean age 61.1±9.3 years) implanted with the EPIC self-expanding nitinol stent system in 166 de novo or restenotic iliac artery lesions ≤13 cm long. The primary endpoint was the 9-month major adverse event rate [i.e., device- or procedure-related death within 30 days, myocardial infarction during the index hospitalization, target vessel revascularization (TVR), or index limb amputation]. Follow-up occurred at hospital discharge and at 1, 9, and 12 months. An independent core laboratory evaluated ultrasound results at 1, 9, and 12 months. The primary endpoint met the prespecified performance goal, with only 3.4% (4/117) of patients experiencing a major adverse event by 9 months (p<0.0001). By 12 months, 6 (5.4%) of 111 patients had TVR; none had an index limb amputation. The ankle-brachial index, Walking Impairment Questionnaire, and Rutherford classifications all showed sustained improvements through 12 months. Primary patency was 94.4% with comparable results for lesions classified as complex (TASC II C/D 95.5%) or non-complex (TASC II A/B 95.0%). The EPIC stent system demonstrated safety and effectiveness through 12 months, including improvements for complex lesions. The EPIC stent is a viable alternative to surgery for patients with either complex or non-complex lesions.

  9. The 6-F nitinol TrapEase inferior vena cava filter: results of a prospective multicenter trial.

    Science.gov (United States)

    Rousseau, H; Perreault, P; Otal, P; Stockx, L; Golzarian, J; Oliva, V; Reynaud, P; Raat, F; Szatmari, F; Santoro, G; Emanuelli, G; Nonent, M; Hoogeveen, Y

    2001-03-01

    The authors report the first results of a new 6-F symmetrically designed permanent nitinol inferior vena cava (IVC) filter, the Cordis TrapEase, evaluated in a multicenter prospective study with 6-months of follow-up. A total of 65 patients (29 men, 36 women) who ranged in age from 37 to 96 years (mean age, 68 years) and who were at high risk of pulmonary embolism (PE) were enrolled in 12 centers in Europe and Canada. The study was approved by the institutional review boards at all centers. Study objectives were to evaluate filter effectiveness, filter stability, and caval occlusion. Indications for filter placement were deep vein thrombosis with recurrent thromboembolism and/or free-floating thrombus with contraindication to anticoagulation in 37 patients, and complications in achieving adequate anticoagulation in 28 patients. Follow-up included clinical examination, plain film, Doppler ultrasound, CT scan, and nuclear medicine. The analysis of the data revealed a technical success of 95.4% (three filter-system related implantations not at the intended site, no events of filter tilting) and a clinical success of 100% at 6 months (no cases of symptomatic PE), the study primary endpoint. There were no cases (0%) of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study period, there were two cases of filter thrombosis: one case of early symptomatic thrombosis that was successfully treated in the hospital, and one case of nonsymptomatic filter thrombosis detected at 1-month follow-up, with spontaneous recanalization at 3 months. In the latter patient, some residual thrombus was still detected at 6 months. Of the study population of 65 patients, there were 23 deaths. These deaths were not related to the device or the implantation procedure but to the underlying disease process. This study demonstrates the new nitinol permanent IVC filter to be a safe and an effective device, with a low overall complication rate, for

  10. Temporary metallic stent placement in the treatment of refractory benign esophageal strictures: results and factors associated with outcome in 55 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Kim, Kyung Rae; Shin, Ji Hoon; Lim, Jin-Oh [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Song, Ho-Young [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea)]|[University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Seoul (Korea); Choi, Eugene K. [Weill Medical College of Cornell University, New York, NY (United States)

    2009-02-15

    The purpose of this study was to evaluate the effectiveness of temporary metallic stenting in 55 patients with treatment-resistant benign esophageal strictures and to identify factors associated with clinical outcomes. Under fluoroscopic guidance, covered retrievable stents were placed in 55 patients with benign esophageal strictures and were removed with retrieval hook 1 week to 6 months after placement. Stent placement was successful in all patients, and the mean dysphagia score was reduced from 2.8 to 1.3 (p<0.001). The most common complications were tissue hyperproliferation (31%), severe pain (24%), and stent migration (25%). During follow-up (mean: 38 months), recurrence of the stricture necessitating balloon dilation was seen in 38 (69%) of 55 patients. Maintained patency rates after temporary stenting at 1, 3, and 6 months and 1, 2, and 4 years were 58%, 43%, 38%, 33%, 26%, and 21%, respectively. In multivariate analysis, length (p=0.003) of the stricture was the only significant factor associated with maintained patency after temporary stenting. In conclusion, temporary metallic stenting for refractory benign esophageal strictures may be effective during the period of stent placement, but is disadvantaged by the high recurrence rates after stent removal, particularly in patients with a long length of stricture (>7cm). (orig.)

  11. Large capacity temporary visual memory

    Science.gov (United States)

    Endress, Ansgar D.; Potter, Mary C.

    2014-01-01

    Visual working memory (WM) capacity is thought to be limited to three or four items. However, many cognitive activities seem to require larger temporary memory stores. Here, we provide evidence for a temporary memory store with much larger capacity than past WM capacity estimates. Further, based on previous WM research, we show that a single factor — proactive interference — is sufficient to bring capacity estimates down to the range of previous WM capacity estimates. Participants saw a rapid serial visual presentation (RSVP) of 5 to 21 pictures of familiar objects or words presented at rates of 4/s or 8/s, respectively, and thus too fast for strategies such as rehearsal. Recognition memory was tested with a single probe item. When new items were used on all trials, no fixed memory capacities were observed, with estimates of up to 9.1 retained pictures for 21-item lists, and up to 30.0 retained pictures for 100-item lists, and no clear upper bound to how many items could be retained. Further, memory items were not stored in a temporally stable form of memory, but decayed almost completely after a few minutes. In contrast, when, as in most WM experiments, a small set of items was reused across all trials, thus creating proactive interference among items, capacity remained in the range reported in previous WM experiments. These results show that humans have a large-capacity temporary memory store in the absence of proactive interference, and raise the question of whether temporary memory in everyday cognitive processing is severely limited as in WM experiments, or has the much larger capacity found in the present experiments. PMID:23937181

  12. Laser-assisted fixation of a nitinol stapes prosthesis.

    Science.gov (United States)

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Meaningful radiation worker training for temporary craftsmen

    International Nuclear Information System (INIS)

    Williams, S.L.

    1976-01-01

    The carefully organized Radiation Worker Training Program presented to permanently assigned personnel at a power reactor facility too often falls by the wayside when temporary craftsmen are brought in for an outage. Even though these temporary workers will frequently be assigned to outage jobs with high radiation and/or contamination exposures, their Radiation Worker Training is often squeezed into an already busy schedule, thus reducing its effectiveness. As an aid for evaluating the effectiveness of an existing Radiation Worker Training Program for temporary craftsmen or for setting up a new program, the following guides are presented and discussed in this paper: the training environment; the interest and meaningfulness of the presentation; the method or methods used for presentation of the training information; the use of demonstrations; trainee participation; and, measuring the amount and type of information retained by a trainee. Meaningful Radiation Worker Training for temporary craftsmen can pay big dividends. Craftsmen can be expected to make fewer mistakes, thus reducing radiation exposure and lessening the chance for the spread of contamination. The craftsmen will also benefit by being able to work longer and utility management will benefit by having lower outage costs

  14. 26 CFR 1.181-0T - Table of contents (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Table of contents (temporary). 1.181-0T Section...-0T Table of contents (temporary). This section lists the table of contents for §§ 1.181-1T through 1... deduction allowed. § 1.181-2TElection (temporary). (a) Time and manner of making election. (b) Election by...

  15. PEEK (polyether-ether-ketone)-coated nitinol wire: Film stability for biocompatibility applications

    Science.gov (United States)

    Sheiko, Nataliia; Kékicheff, Patrick; Marie, Pascal; Schmutz, Marc; Jacomine, Leandro; Perrin-Schmitt, Fabienne

    2016-12-01

    High quality biocompatible poly-ether-ether-ketone (PEEK) coatings were produced on NiTi shape memory alloy wires using dipping deposition from colloidal aqueous PEEK dispersions after substrate surface treatment. The surface morphology and microstructure were investigated by Scanning Electron Microscopy at every step of the process from the as-received Nitinol substrate to the ultimate PEEK-coated NiTi wire. Nanoscratch tests were carried out to access the adhesive behavior of the polymer coated film to the NiTi. The results indicate that the optimum process conditions in cleaning, chemical etching, and electropolishing the NiTi, were the most important and determining parameters to be achieved. Thus, high quality PEEK coatings were obtained on NiTi wires, straight or curved (even with a U-shape) with a homogeneous microstructure along the wire length and a uniform thickness of 12 μm without any development of cracks or the presence of large voids. The biocompatibility of the PEEK coating film was checked in fibrobast cultured cells. The coating remains stable in biological environment with negligible Ni ion release, no cytotoxicity, and no delamination observed with time.

  16. Temporary and Travelling Exhibitions. Museums and Monuments, X.

    Science.gov (United States)

    Daifuku, Hiroshi; And Others

    The permanent exhibition, the most typical form of museum exhibition, has failed to attract repeated visitation, since visitors quickly become familiar with the objects shown. The temporary exhibition evolved as a result for the need of repeated visitation. The temporary exhibition, set up for a period of one to six months, introduces fresh…

  17. 26 CFR 1.267(a)-2T - Temporary regulations; questions and answers arising under the Tax Reform Act of 1984 (temporary).

    Science.gov (United States)

    2010-04-01

    ... Act of 1984 (temporary). (a) Introduction—(1) Scope. This section prescribes temporary question and... the person to whom the payment is to be made properly uses the completed contract method of accounting... amount is owed to a related person under whose method of accounting such amount is not includible in...

  18. Heparin-bonded covered stents versus bare-metal stents for complex femoropopliteal artery lesions: the randomized VIASTAR trial (Viabahn endoprosthesis with PROPATEN bioactive surface [VIA] versus bare nitinol stent in the treatment of long lesions in superficial femoral artery occlusive disease).

    Science.gov (United States)

    Lammer, Johannes; Zeller, Thomas; Hausegger, Klaus A; Schaefer, Philipp J; Gschwendtner, Manfred; Mueller-Huelsbeck, Stefan; Rand, Thomas; Funovics, Martin; Wolf, Florian; Rastan, Aljoscha; Gschwandtner, Michael; Puchner, Stefan; Ristl, Robin; Schoder, Maria

    2013-10-08

    The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long lesions remains unsatisfactory. In a prospective, randomized, single-blind, multicenter study, 141 patients with symptomatic peripheral arterial disease were assigned to treatment with heparin-bonded, covered stents (Viabahn 72 patients) or BMS (69 patients). Clinical outcomes and patency rates were assessed at 1, 6, and 12 months. Mean ± SD lesion length was 19.0 ± 6.3 cm in the Viabahn group and 17.3 ± 6.6 cm in the BMS group. Major complications within 30 days were observed in 1.4%. The 12-month primary patency rates in the Viabahn and BMS groups were: intention-to-treat (ITT) 70.9% (95% confidence interval [CI]: 0.58 to 0.80) and 55.1% (95% CI: 0.41 to 0.67) (log-rank test p = 0.11); treatment per-protocol (TPP) 78.1% (95% CI: 0.65 to 0.86) and 53.5% (95% CI: 0.39 to 0.65) (hazard ratio: 2.23 [95% CI: 1.14 to 4.34) (log-rank test p = 0.009). In lesions ≥20 cm, (TransAtlantic Inter-Society Consensus class D), the 12-month patency rate was significantly longer in VIA patients in the ITT analysis (VIA 71.3% vs. BMS 36.8%; p = 0.01) and the TPP analysis (VIA 73.3% vs. BMS 33.3%; p = 0.004). Freedom from target lesion revascularization was 84.6% for Viabahn (95% CI: 0.72 to 0.91) versus 77.0% for BMS (95% CI: 0.63 to 0.85; p = 0.37). The ankle-brachial index in the Viabahn group significantly increased to 0.94 ± 0.23 compared with the BMS group (0.85 ± 0.23; p stents compared with BMS in lesions ≥20 cm and for all lesions in the TPP analysis. In the ITT analysis for all lesions, which was flawed by major protocol deviations in 8.5% of the patients, the difference was not significant. (GORE VIABAHN® endoprosthesis with bioactive propaten surface versus bare

  19. Temporary brittle bone disease: fractures in medical care.

    Science.gov (United States)

    Paterson, Colin R

    2009-12-01

    Temporary brittle bone disease is the name given to a syndrome first reported in 1990, in which fractures occur in infants in the first year of life. The fractures include rib fractures and metaphyseal fractures which are mostly asymptomatic. The radiological features of this disorder mimic those often ascribed to typical non-accidental injury. The subject has been controversial, some authors suggesting that the disorder does not exist. This study reports five infants with typical features of temporary brittle bone disease in whom all or most of the fractures took place while in hospital. A non-accidental cause can be eliminated with some confidence, and these cases provide evidence in support of the existence of temporary brittle bone disease.

  20. Conversion of a Temporary Tent with Steel Frame into a Permanent Warehouse

    Science.gov (United States)

    Georgescu, Mircea; Ungureanu, Viorel; Grecea, Daniel; Petran, Ioan

    2017-10-01

    The paper is dealing with the problem of a functional conversion (involving both architectural and structural issues) applied to the case of an industrial building. As well known, temporary tents, designed according to the European Code EN13782, represent a remarkable stake on the building market and a fast and practical solution for some situations. It is exactly the case approached by the paper, where the investor has initially decided to erect on his platform a provisional shelter for agricultural machines and subsequent staff, built of a light steel structure covered by PVC roofing and cladding. This temporary tent has been acquired from a specialized supplier in form of a series product. After using the tent for a number of years, the investor has decided to convert the existing structure from architectural and structural point of view by switching to a permanent structure designed accordingly. Important changes were thus imposed both to the architectural part (technological flows, openings, facades) and especially to the structural part where this switch imposed a re-design to the codes of permanent structures (especially as far as climatic loadings are concerned). The required architectural change implied the building of a 70 cm high concrete plinth and replacing the PVC membrane temporary roofing and cladding by permanent 60 mm thick PUR sandwich panels. Together with a new system of openings this has led to renewed facades of the buildings. As for the structural change, the required conversion has imposed a thorough checking of the existing steel structure (very slender and typical to a tent) in view of transforming it into a permanent structure. The consolidation measures of the existing galvanized steel structure are described, together with the measures applied at infrastructure level in order to implement the required conversion.

  1. 47 CFR 25.277 - Temporary fixed earth station operations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Temporary fixed earth station operations. 25.277 Section 25.277 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Technical Operations § 25.277 Temporary fixed earth station operations...

  2. Carbon Reduction Measures-Based LCA of Prefabricated Temporary Housing with Renewable Energy Systems

    Directory of Open Access Journals (Sweden)

    Ling Dong

    2018-03-01

    Full Text Available Temporary housing plays an important role in providing secure, hygienic, private, and comfortable shelter in the aftermath of disaster (such as flood, fire, earthquake, etc.. Additionally, temporary housing can also be used as a sustainable form of on-site residences for construction workers. While most of the building components used in temporary housing can be manufactured in a plant, prefabrication technology improves the production efficiency of temporary housing; furthermore, integrated renewable energy systems, for example, solar photovoltaic (PV system, offer benefits for temporary housing operations. In order to assess the environmental impacts of prefabricated temporary housing equipped with renewable energy systems, this study first divides the life cycle of temporary housing into six stages, and then establishes a life cycle assessment (LCA model for each stage. Furthermore, with the aim of reducing the environmental impacts, life cycle carbon reduction measures are proposed for each stage of temporary housing. The proposed methodology is demonstrated using a case study in China. Based on the proposed carbon reduction measures, the LCA of a prefabricated temporary housing case study building equipped with renewable energy systems indicates a carbon emissions intensity of 35.7 kg/m2·per year, as well as a reduction in material embodied emissions of 18%, assembly emissions of 17.5%, and operational emissions of 91.5%. This research proposes a carbon reduction-driven LCA of temporary housing and contributes to promoting sustainable development of prefabricated temporary housing equipped with renewable energy systems.

  3. 26 CFR 1.181-5T - Examples (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Examples (temporary). 1.181-5T Section 1.181-5T...) INCOME TAXES Itemized Deductions for Individuals and Corporations (continued) § 1.181-5T Examples (temporary). The following examples illustrate the application of §§ 1.181-1T through 1.181-4T: Example 1. X...

  4. 33 CFR 74.01-15 - Charges for placement of temporary aids.

    Science.gov (United States)

    2010-07-01

    ... temporary aids. 74.01-15 Section 74.01-15 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION CHARGES FOR COAST GUARD AIDS TO NAVIGATION WORK Charges to the Public § 74.01-15 Charges for placement of temporary aids. Charges for placement of temporary aids will be...

  5. Temporary Clusters and Knowledge Creation

    DEFF Research Database (Denmark)

    Maskell, Peter; Bathelt, Harald; Malmberg, Anders

    2004-01-01

    or participating in such events are means toidentify the current market frontier, take stock of relative competitive positions and formfuture plans. These events exhibit many of the characteristics ascribed to permanentclusters, albeit in a temporary, periodic and intensified form. The temporary clusters...... arehotspots of intense knowledge exchange, network building and idea generation.In investigating the extent and nature of these phenomena, the present paper explores anumber of issues. First, it shows that international trade fairs and other professionalgatherings are events which enable firms to compare...... their own products with others whichare available to the world market. Comparisons to and interactions with other firmsstimulate processes of knowledge creation. Second, it demonstrates how trade fairs areimportant for firms when selecting partners with whom to develop global pipelines,enabling access...

  6. Impact of a temporary stoma on patients' everyday lives

    DEFF Research Database (Denmark)

    Danielsen, Anne K; Soerensen, Erik E; Burcharth, Kirsten

    2013-01-01

    AIMS AND OBJECTIVES: To examine patients' experiences of impact of a temporary stoma on their everyday life. Furthermore, we wanted to generate new knowledge and comprehension of learning how to live with a temporary stoma. BACKGROUND: There are many aspects, largely unexplored, that may influenc...

  7. 76 FR 34080 - Agency Information Collection Activities; Proposed Collection; Comment Request; Temporary...

    Science.gov (United States)

    2011-06-10

    ...] Agency Information Collection Activities; Proposed Collection; Comment Request; Temporary Marketing... appropriate, and other forms of information technology. Temporary Marketing Permit Applications--21 CFR 130.17... submitted recent requests for temporary marketing permits. Based on this information, we estimate that there...

  8. Temporary tattoos: a novel OSCE assessment tool.

    Science.gov (United States)

    Gormley, Gerry; Menary, Allison; Layard, Brooke; Hart, Nigel; McCourt, Collette

    2013-08-01

    There are many issues regarding the use of real patients in objective structured clinical examinations (OSCEs). In dermatology OSCE stations, standardised patients (SPs) with clinical photographs are often used. Temporary transfer tattoos can potentially simulate skin lesions when applied to an SP. This study aims to appraise the use of temporary malignant melanoma tattoos within an OSCE framework. Within an 11-station OSCE, a temporary malignant melanoma tattoo was developed and applied to SPs in a 'skin lesion' OSCE station. A questionnaire captured the opinions of the candidate, SP and examiners, and the degree of perceived realism of each station was determined. Standard post hoc OSCE analysis determined the psychometric reliability of the stations. The response rates were 95.9 per cent of candidates and 100 per cent of the examiners and SPs. The 'skin lesion' station achieved the highest realism score compared with other stations: 89.0 per cent of candidates felt that the skin lesion appeared realistic; only 28 per cent of candidates had ever seen a melanoma before in training. The psychometric performance of the melanoma station was comparable with, and in many instances better than, other OSCE stations. Transfer tattoo technology facilitates a realistic dermatology OSCE station encounter. Temporary tattoos, alongside trained SPs, provide an authentic, standardised and reliable experience, allowing the assessment of integrated dermatology clinical skills. © 2013 John Wiley & Sons Ltd.

  9. Local hypertrichosis: A rare complication of a temporary henna tattoo.

    Science.gov (United States)

    Akpolat, Nebahat Demet; Aras, Arzu

    2016-01-01

    Temporary henna tattoos have become increasingly widespread among children and young people, especially in holiday spots in recent years. Although reactions to henna tattoo are becoming progressively more common, only few cases of a henna pseudo-tattoo resulting in temporary hypertrichosis have been reported so far. Here, we have reported a 5-year-old girl who developed allergic contact dermatitis and localized hypertrichosis on her right arm after application of temporary henna tattoo during summer holiday.

  10. The Temporal Organization Grid: A New Classification System of Temporary Organizations

    Directory of Open Access Journals (Sweden)

    Vallari Chandna

    2017-03-01

    Full Text Available With the increased recognition of the key role played by time in processes and outcomes, there has been a renewed focus on temporary organizations. Temporary organizational forms tend to receive attention due to certain characteristics that are unique to them, as compared to permanent organizations, with regard to issues like trust, communication, organizational structure, innovation and creativity among others. They have also been known to generate significant benefits for the organizations participating in them. But to study them in detail, a comprehensive classification system of temporary organizations is needed, which has so far been missing in the extant literature. This paper sets forth a classification grid for temporary organizations which is its primary purpose and also examines the different strategically important variables that further define the typological framework and that act as determinants of success of these temporary organizations.

  11. Temporary quadriplegia following continuous thoracic paravertebral block.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Danielou, Eric; Michelin, Paul

    2012-05-01

    A case of temporary quadriplegia following a continuous thoracic paravertebral block in an adult patient scheduled for video-assisted thoracoscopy is presented. An 18-gauge Tuohy needle was inserted under direct vision by the surgeon but the tip of the catheter was not localized. Postoperatively, the patient developed temporary quadriplegia 90 minutes after the start of a continuous infusion of ropivacaine 0.2%. Imaging studies showed that the catheter was localized in the intrathecal space. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. 40 CFR 310.10 - What are temporary emergency measures?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 27 2010-07-01 2010-07-01 false What are temporary emergency measures... RESPONSE TO HAZARDOUS SUBSTANCE RELEASES Provisions What Can Be Reimbursed? § 310.10 What are temporary... security; (2) Controlling the source of contamination; (3) Containing the release to prevent spreading; (4...

  13. A newly-designed temporary cardia stent for the treatment of achalasia:an experimental study in canine models

    International Nuclear Information System (INIS)

    Kuang Xiaochun; Cheng Yingsheng; Zhu Yueqi; Li Feng; Wang Weiguo

    2010-01-01

    Objective: To assess the efficacy and safety of a newly-designed temporary covered cardia stent for the treatment of achalasia in canine models and to investigate the histopathological changes at different points of follow-up time after the stent was removed. Methods: The canine achalasia model was created by injecting benzyl-dimethyl-tetradecyl ammonium chloride (BAC) circumferentially into the lower esophageal sphincter (LES) of the dogs. Twenty-four dogs with achalasia were randomly and equally divided into two groups with 12 dogs in each group: control group (using routine esophageal stents) and study group (using newly-designed temporary covered cardia stents). Under fluoroscopic guidance stents were implanted in the esophagus and were taken away from the esophagus 4 days after stent insertion in experimental dogs of both groups. LES pressures and timed barium esophagography (TBE) were performed in all dogs before and immediately after the stenting procedure, as well as at one week, 3 and 6 months after the stent was removed. Every three dogs were sacrificed each time at one week, 3 and 6 months after the stent was removed. The esophageal cardia was excised and sent for pathological examination. Results: All animals well tolerated the stent insertion / removal and the follow-up procedures. No severe complications such as esophageal perforation occurred. Comparison between two groups showed that stent migration occurrence was much lower in study group (n = 1) than that in control group (n = 5). The reduction of LES pressures in study group was more significant in comparison with control group (at 6-month follow-up, P = 0.027). The difference in barium column product (height x width) between 0-min and 5-min TBE was statistically significant in study group (at 3-month follow-up, P = 0.009). Integrated analysis of multi-comparison for LES pressures among subgroups of each group revealed that the dogs in study group exhibited better outcomes than the dogs in

  14. Partially covered versus uncovered self-expandable nitinol stents with anti-migration properties for the palliation of malignant distal biliary obstruction: A randomized controlled trial.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Yoo, Byung Moo; Hwang, Jae Chul; Yoo, Jun Hwan; Lee, Ki Seong; Kang, Joon Koo; Kim, Soon Sun; Lim, Sun Gyo; Shin, Sung Jae; Cheong, Jae Youn; Lee, Kee Myung; Lee, Kwang Jae; Cho, Sung Won

    2015-01-01

    Covered self-expandable metal stents (SEMSs) are increasingly used as alternatives to uncovered SEMSs for the palliation of inoperable malignant distal biliary obstruction to counteract tumor ingrowth. We aimed to compare the outcomes of partially covered and uncovered SEMSs with identical mesh structures and anti-migration properties, such as low axial force and flared ends. One hundred and three patients who were diagnosed with inoperable malignant distal biliary obstruction between January 2006 and August 2013 were randomly assigned to either the partially covered (n = 51) or uncovered (n = 52) SEMS group. There were no significant differences in the cumulative stent patency, overall patient survival, stent dysfunction-free survival and overall adverse events, including pancreatitis and cholecystitis, between the two groups. Compared to the uncovered group, stent migration (5.9% vs. 0%, p = 0.118) and tumor overgrowth (7.8% vs. 1.9%, p = 0.205) were non-significantly more frequent in the partially covered group, whereas tumor ingrowth showed a significantly higher incidence in the uncovered group (5.9% vs. 19.2%, p = 0.041). Stent migration in the partially covered group occurred only in patients with short stenosis of the utmost distal bile duct (two in ampullary cancer, one in bile duct cancer), and did not occur in any patients with pancreatic cancer. For the palliation of malignant distal biliary obstruction, endoscopic placement of partially covered SEMSs with anti-migration designs and identical mesh structures to uncovered SEMSs failed to prolong cumulative stent patency or reduce stent migration.

  15. 26 CFR 1.846-4T - Effective dates (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Effective dates (temporary). 1.846-4T Section 1.846-4T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Other Insurance Companies § 1.846-4T Effective dates (temporary). (a) [Reserved...

  16. 26 CFR 20.2032-1T - Alternate valuation (temporary).

    Science.gov (United States)

    2010-04-01

    ...) the value of the property as of the alternate valuation date. For example, assume that the decedent... 26 Internal Revenue 14 2010-04-01 2010-04-01 false Alternate valuation (temporary). 20.2032-1T...-1T Alternate valuation (temporary). (a) through (e) [Reserved] For further guidance, see § 20.2032-1...

  17. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  18. The Temporary Help Industry: A Response to the Dual Internal Labor Market.

    Science.gov (United States)

    Mangum, Garth; And Others

    1985-01-01

    This study of the rapidly growing temporary help industry draws on Commerce Department data and the results of the authors' national mail survey of employers. The authors also conducted interviews in the San Francisco area with employers of temporary help and with representatives of temporary help agencies and labor unions. (Author/CT)

  19. 20 CFR 416.1167 - Temporary absences and deeming rules.

    Science.gov (United States)

    2010-04-01

    ... FOR THE AGED, BLIND, AND DISABLED Income Deeming of Income § 416.1167 Temporary absences and deeming..., we consider your absence to be temporary through the date of discharge. (b) Child away at school. If you are an eligible child who is away at school but comes home on some weekends or lengthy holidays...

  20. Temporary Agency Work as a Means of Achieving Flexicurity?

    Directory of Open Access Journals (Sweden)

    Kristina Håkansson

    2012-11-01

    Full Text Available After decades of debate about flexibility, flexicurity has become a new buzzword in working life. Flexicurity refers to both the employer’s demand for flexibility and the employee’s demand for security. Thus, the idea is to solve the flexibility–security trade-off. There is also a discussion that mentions temporary agency work as one way of creating a flexicurity system. The flexibility potential is not called into question—numerical flexibility is a quite common motive for using temporary agency workers. However, the security dimension has to be scrutinized. The aim of this article is to analyze the temporary work agency industry’s potential for providing the security dimensions of the flexicurity model in a Swedish context. The study is based on a survey of whitecollar temporary agency workers in Sweden (n = 533. Overall, the vast majority do not perceive security. Our most important result is that both the work agency and the user firm have a dual impact on the agency workers’ perception of security.

  1. CHARACTERIZING SURFACE LAYERS IN NITINOL USING X-RAY PHOTOELECTRON SPECTROSCOPY

    Energy Technology Data Exchange (ETDEWEB)

    Christopfel, R.; Mehta, A.

    2008-01-01

    Nitinol is a shape memory alloy whose properties allow for large reversible deformations and a return to its original geometry. This nickel-titanium (NiTi) alloy has become a material used widely in the biomedical fi eld as a stent to open up collapsed arteries. Both ambient and biological conditions cause surface oxidation in these devices which in turn change its biocompatibility. The thickness of oxidized layers can cause fractures in the material if too large and can allow for penetration if too thin. Depending on the type and abundance of the chemical species on or near the surface, highly toxic metal ions can leak into the body causing cell damage or even cell death. Thus, biocompatibility of such devices is crucial. By using highly surface sensitive x-ray photoelectron spectroscopy to probe the surface of these structures, it is possible to decipher both layer composition and layer thickness. Two samples, both of which were mechanically polished, were investigated. Of the two samples, one was then exposed to a phosphate buffered saline (PBS) solution to mimic the chemical properties of blood, while the other remained unexposed. Although both samples were found to have oxide layers of appropriate thickness (on the order of a few nm), it was found that the sample exposed to the saline solution had a slightly thicker oxide layer and more signifi cantly, a phosphate layer very near the surface suggesting toxic metal components are well contained within the sample. These are considerable indications of a biocompatible device.

  2. Safety and efficacy of a fully covered large-diameter self-expanding metal stent for the treatment of upper gastrointestinal perforations, anastomotic leaks, and fistula

    NARCIS (Netherlands)

    van den Berg, M. W.; Kerbert, A. C.; van Soest, E. J.; Schwartz, M. P.; Bakker, C. M.; Gilissen, L. P. L.; van Hooft, J. E.

    2016-01-01

    Upper gastrointestinal perforations, fistula, and anastomotic leaks are severe conditions with high mortality. Temporary endoscopic placement of fully covered self-expanding metal stent (fSEMS) has emerged as treatment option. Stent migration is a major drawback of currently used stents. Migration

  3. AGENCY CONTRIBUTION IN ACHIEVING TEMPORARY AGENCY WORKERS’ ORGANIZATIONAL COMMITMENT: A STUDY IN ABC (PVT LTD

    Directory of Open Access Journals (Sweden)

    T.G.T.N Perera

    2017-12-01

    Full Text Available Temporary agency workers are coming under non-standard employments, who have temporary attachment to the working organization. With dynamic business environment and flexible work arrangements, temporary agency employments are also emerged in Sri Lanka. Temporary agency workers are dual committed employees. However, with this dual commitment, organizations face issues in achieving temporary agency workers’ commitment due to low attention of agencies to temporary agency workers. Even though the Client organization provides due attention to temporary agency workers, they fail to receive due commitment due to the lack of attention from agency to temporary agency workers. This study was conducted to identify the agency related factors affecting temporary agency workers’ commitment. This was carried out as a cross sectional field study with a sample of 93 workers from temporary agency works in the ABC (pvt ltd. 93 temporary agency workers were selected as sample. Data were collected via a standard questionnaire that met accepted standards of validity and reliability. Descriptive statistics, Simple ranking, Factor analysis, ANOVA and Independent Sample T-Test technique were performed to analyze data. No of Temporary workers to supervisor (temp to consult ratio is the most influencing factor of temporary agency workers’ commitment in agency context. Job satisfaction, agency support, side bets, interactional justice, lack of alternative employments, procedural justice, distributive justice, reciprocity norm acceptance, socialization, breach of psychological contract, lack of skill transferability are the other factors, which are ordered from most influencing factor to less affecting factor to workers’ organizational commitment . Findings revealed that eleven out of thirteen factors are job related factors, other two are organization related and person related factors. Most client companies provide their attention, while agencies fail to provide

  4. Influence of dentin contamination by temporary cements on the bond strength of adhesive systems

    Directory of Open Access Journals (Sweden)

    Josimeri Hebling

    2009-01-01

    Full Text Available Objective: The aim of this study was to assess the bond strength of adhesive systems to dentin contaminated by temporary cements with or without eugenol. Method: Flat dentin surfaces were obtained from twenty-four human third molars. With exception of the control group (n=8, the surfaces were covered with Interim Restorative Material (Caulk Dentsplay, Milford, DE, USA or Cavit (3M ESPE, St. Paul, MN, USA and kept in an oven at 37oC for seven days. After removing the cements, the adhesive systems Adper Single Bond (3M ESPE, St. Paul, MN, USA or Clearfil SE Bond (Kuraray Co. Ltd., Osaka, Japan were applied in accordance with the manufacturers’ recommendations, and then the crowns were constructed in of resin composite. The teeth were sectioned into specimens with a cross-sectional bond area of 0.81mm2, which were sub mitted to microtensile testing in a mechanical test machine at an actuator speed of 0.5mm/min. The data were analyzed by t- and ANOVA tests, complemented by Tukey tests (α=0.05. Results: For Adper Single Bond (3M ESPE, St. Paul, MN, USA, bond strength did not differ statistically (p>0.05 for all the experimental conditions. For Clearfil SE Bond (Kuraray Co. Ltd., Osaka, Japan, only the Interim Restorative Material (Caulk Dentsplay, Milford, DE, USA Group showed significantly lower bond strength (30.1±13.8 MPa in comparison with the other groups; control (38.9±13.5 MPa and Cavit (3M ESPE, St. Paul, MN, USA (42.1±11.0 MPa, which showed no significant difference between them.Conclusion: It was concluded that the previous covering of dentin with temporary cement containing eugenol had a deleterious effect on the adhesive performance of the self-etching system only.

  5. Estimating temporary emigration and breeding proportions using capture-recapture data with Pollock's robust design

    Science.gov (United States)

    Kendall, W.L.; Nichols, J.D.; Hines, J.E.

    1997-01-01

    Statistical inference for capture-recapture studies of open animal populations typically relies on the assumption that all emigration from the studied population is permanent. However, there are many instances in which this assumption is unlikely to be met. We define two general models for the process of temporary emigration, completely random and Markovian. We then consider effects of these two types of temporary emigration on Jolly-Seber (Seber 1982) estimators and on estimators arising from the full-likelihood approach of Kendall et al. (1995) to robust design data. Capture-recapture data arising from Pollock's (1982) robust design provide the basis for obtaining unbiased estimates of demographic parameters in the presence of temporary emigration and for estimating the probability of temporary emigration. We present a likelihood-based approach to dealing with temporary emigration that permits estimation under different models of temporary emigration and yields tests for completely random and Markovian emigration. In addition, we use the relationship between capture probability estimates based on closed and open models under completely random temporary emigration to derive three ad hoc estimators for the probability of temporary emigration, two of which should be especially useful in situations where capture probabilities are heterogeneous among individual animals. Ad hoc and full-likelihood estimators are illustrated for small mammal capture-recapture data sets. We believe that these models and estimators will be useful for testing hypotheses about the process of temporary emigration, for estimating demographic parameters in the presence of temporary emigration, and for estimating probabilities of temporary emigration. These latter estimates are frequently of ecological interest as indicators of animal movement and, in some sampling situations, as direct estimates of breeding probabilities and proportions.

  6. Temporary Residences: a becoming project

    Directory of Open Access Journals (Sweden)

    Luisa Ingaramo

    2012-04-01

    Full Text Available Among the experimental actions fostered so far by the Compagnia di San Paolo through its Housing Program, committed in handling the complex and fragmented housing discomfort issue, the Temporary Dwellings initiative represents a unique and innovative experience, as it actually offers the chance to activate a proper managerial direction around and about the real estate development processes. In particular, the Temporary Dwellings action is marked by two key aspects: a structured co-planning vision and projects selected through a requests for proposal system. The process in the whole aims on the one hand at reaching an high transparent level of decision making , while, on the other hand, at developing a continuous and mutual monitoring and matching activity between the Housing Program and the group of cross-curricular experts teamed up in the project: technicians, designers, managers, psychologists, contractors, and the other local stakeholders.

  7. 26 CFR 301.7701-2T - Business entities; definitions (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Business entities; definitions (temporary). 301... (CONTINUED) PROCEDURE AND ADMINISTRATION PROCEDURE AND ADMINISTRATION Definitions § 301.7701-2T Business entities; definitions (temporary). (a) through (c)(2)(ii) [Reserved] For further guidance, see § 301.7701-2...

  8. 19 CFR 210.69 - Approval of complainant's temporary relief bond.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Approval of complainant's temporary relief bond. 210.69 Section 210.69 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Temporary Relief § 210.69 Approval of...

  9. Indications, management, and complications of temporary inferior vena cava filters

    International Nuclear Information System (INIS)

    Linsenmaier, Ulrich; Rieger, Johannes; Schenk, Franz; Rock, Clemens; Mangel, Eugen; Pfeifer, Klaus Juergen

    1998-01-01

    Purpose: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters.Methods: Fifty temporary IVC filters (Guenther, Guenther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis.Results: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis.Conclusion: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.

  10. Rapid in situ growth of oriented titanium-nickel oxide composite nanotubes arrays coated on a nitinol wire as a solid-phase microextraction fiber coupled to HPLC-UV.

    Science.gov (United States)

    Zhen, Qi; Zhang, Min; Song, Wenlan; Wang, Huiju; Wang, Xuemei; Du, Xinzhen

    2016-10-01

    An oriented titanium-nickel oxide composite nanotubes coating was in situ grown on a nitinol wire by direct electrochemical anodization in ethylene glycol with ammonium fluoride and water for the first time. The morphology and composition of the resulting coating showed that the anodized nitinol wire provided a titania-rich coating. The titanium-nickel oxide composite nanotubes coated fiber was used for solid-phase microextraction of different aromatic compounds coupled to high-performance liquid chromatography with UV detection. The titanium-nickel oxide composite nanotubes coating exhibited high extraction capability, good selectivity, and rapid mass transfer for weakly polar UV filters. Thereafter the important parameters affecting extraction efficiency were investigated for solid-phase microextraction of UV filters. Under the optimized conditions, the calibration curves were linear in the range of 0.1-300 μg/L for target UV filters with limits of detection of 0.019-0.082 μg/L. The intraday and interday precision of the proposed method with the single fiber were 5.3-7.2 and 5.9-7.9%, respectively, and the fiber-to-fiber reproducibility ranged from 6.3 to 8.9% for four fibers fabricated in different batches. Finally, its applicability was evaluated by the extraction and determination of target UV filters in environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. 5 CFR 300.503 - Conditions for using private sector temporaries.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Conditions for using private sector... REGULATIONS EMPLOYMENT (GENERAL) Use of Private Sector Temporaries § 300.503 Conditions for using private... help service firm for the brief or intermittent use of the skills of private sector temporaries, when...

  12. 8 CFR 1244.5 - Temporary treatment benefits for eligible aliens.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Temporary treatment benefits for eligible aliens. 1244.5 Section 1244.5 Aliens and Nationality EXECUTIVE OFFICE FOR IMMIGRATION REVIEW, DEPARTMENT... § 1244.5 Temporary treatment benefits for eligible aliens. (a) Prior to the registration period. Prior to...

  13. 30 CFR 75.209 - Automated Temporary Roof Support (ATRS) systems.

    Science.gov (United States)

    2010-07-01

    ... of temporary support shall be used, as specified in the roof control plan, when— (1) Mining... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automated Temporary Roof Support (ATRS) systems... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.209...

  14. Temporary sharing prompts unrestrained disclosures that leave lasting negative impressions.

    Science.gov (United States)

    Hofstetter, Reto; Rüppell, Roland; John, Leslie K

    2017-11-07

    With the advent of social media, the impressions people make on others are based increasingly on their digital disclosures. However, digital disclosures can come back to haunt, making it challenging for people to manage the impressions they make. In field and online experiments in which participants take, share, and evaluate self-photographs ("selfies"), we show that, paradoxically, these challenges can be exacerbated by temporary-sharing media-technologies that prevent content from being stored permanently. Relative to permanent sharing, temporary sharing affects both whether and what people reveal. Specifically, temporary sharing increases compliance with the request to take a selfie (study 1) and induces greater disclosure risks (i.e., people exhibit greater disinhibition in their selfies, studies 1 and 2). This increased disclosure is driven by reduced privacy concerns (study 2). However, observers' impressions of sharers are insensitive to permanence (i.e., whether the selfie was shared temporarily versus permanently) and are instead driven by the disinhibition exhibited in the selfie (studies 4-7). As a result, induced by the promise of temporary sharing, sharers of uninhibited selfies come across as having worse judgment than those who share relatively discreet selfies (studies 1, 2, and 4-7)-an attributional pattern that is unanticipated by sharers (study 3), that persists days after the selfie has disappeared (study 5), is robust to personal experience with temporary sharing (studies 6A and 6B), and holds even among friends (studies 7A and 7B). Temporary sharing may bring back forgetting, but not without introducing new (self-presentational) challenges. Copyright © 2017 the Author(s). Published by PNAS.

  15. Temporary work and depressive symptoms: a propensity score analysis.

    Science.gov (United States)

    Quesnel-Vallée, Amélie; DeHaney, Suzanne; Ciampi, Antonio

    2010-06-01

    Recent decades have seen a tremendous increase in the complexity of work arrangements, through job sharing, flexible hours, career breaks, compressed work weeks, shift work, reduced job security, and part-time, contract and temporary work. In this study, we focus on one specific group of workers that arguably most embodies non-standard employment, namely temporary workers, and estimate the effect of this type of employment on depressive symptom severity. Accounting for the possibility of mental health selection into temporary work through propensity score analysis, we isolate the direct effects of temporary work on depressive symptoms with varying lags of time since exposure. We use prospective data from the U.S. National Longitudinal Survey of Youth 1979 (NLSY79), which has followed, longitudinally, from 1979 to the present, a nationally representative cohort of American men and women between 14 and 22 years of age in 1979. Three propensity score models were estimated, to capture the effect of different time lags (immediately following exposure, and 2 and 4 years post exposure) between the period of exposure to the outcome. The only significant effects were found among those who had been exposed to temporary work in the two years preceding the outcome measurement. These workers report 1.803 additional depressive symptoms from having experienced this work status (than if they had not been exposed). Moreover, this difference is both statistically and substantively significant, as it represents a 50% increase from the average level of depressive symptoms in this population. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Morbidity of temporary loop ileostomies

    NARCIS (Netherlands)

    Bakx, R.; Busch, O. R. C.; Bemelman, W. A.; Veldink, G. J.; Slors, J. F. M.; van Lanschot, J. J. B.

    2004-01-01

    Background/Aims: A temporary loop ileostomy is constructed to protect a distal colonic anastomosis. Closure is usually performed not earlier than 8 - 12 weeks after the primary operation. During this period, stoma-related complications can occur and enhance the adverse effect on quality of life. The

  17. Transforming knowledge across domains in the temporary development spaces

    DEFF Research Database (Denmark)

    Brønnum, Louise

    This paper addresses transformation of knowledge across different knowledge domains and competencies in the Front End of Innovation (FEI) [Koen 2002].We examine the temporary spaces [Clausen, Yoshinaka 2007] that emerge when different knowledge domains are brought into play (implicit or explicit......) in staging innovative concept development. FEI appears as temporary spaces for innovative processes; and studies have pointed out the limited uptake of user knowledge (Elgaard Jensen 2012). This paper will discuss the possibilities and barriers for uptake of user knowledge in FEI in relation...... to the constitutions of these temporary spaces. There seems to be a limited understanding of: how knowledge is transferred and transformed into design objects facilitating a process where knowledge enables innovative thinking across knowledge boundaries. The paper is based on empirical data primarily from case studies...

  18. Temporary Contracts: Effect on Job Satisfaction and Personal Lives of Recent Phd Graduates

    Science.gov (United States)

    Waaijer, Cathelijn J. F.; Belder, Rosalie; Sonneveld, Hans; van Bochove, Cornelis A.; van der Weijden, Inge C. M.

    2017-01-01

    In this study, we assess the effects of temporary employment on job satisfaction and the personal lives of recent PhD graduates. Temporary employment is becoming increasingly prevalent in many sectors, but has been relatively common in academia, especially for early career scientists. Labor market theory shows temporary employment to have a…

  19. The Effect of Operational Cutting Parameters on Nitinol-60 in Wire Electrodischarge Machining

    Directory of Open Access Journals (Sweden)

    Ali Akbar LotfiNeyestanak

    2013-01-01

    Full Text Available Shape memory alloys are a kind of active materials, which have significant characteristics in comparison with other alloys. Since these materials are applicable in different fields such as aerospace, automobile industry, medicine, and dentistry, the effects of wire electrodischarge machining on the properties of these alloys have been studied. In this paper, changes in the shape recovery ability and microhardness of the machined surface of Nitonol-60 shape memory alloy have been studied considering recasting and formation of resolidificated layer on the shape memory alloy surface. XRD and EDXA analyses of the surface layer of the sample besides a microscopic study of the shape memory alloy layer by SEM and a study of the changes in mechanical properties of the surface layer were done by performing microhardness and tension tests on the work piece surface. Considering the surface layer, reversible strain has been studied according to the shape recovery percentage of Nitinol-60 shape memory alloy. Results show that the surface layer formed on the surface of the samples has caused changes in both physical and mechanical properties of the cut surface because of the penetration of the separated materials in comparison with deeper layers of the piece.

  20. Working conditions, work life and quality of life of the temporary ...

    African Journals Online (AJOL)

    Working conditions, work life and quality of life of the temporary support staff ... and expectations of the temporary support staff with regard to their working ... conditions mainly as unpleasant, but that they adapted because of the team spirit.

  1. Temporary emergency pacing-an orphan in district hospitals

    DEFF Research Database (Denmark)

    Gjesdal, Knut; Johansen, Jens Brock; Gadler, Fredrik

    2012-01-01

    This editorial discusses a report on the 1 year experience with temporary pacing, especially in the emergency setting, in several Norwegian district hospitals. The vast majority of the patients received transvenous temporary pacing, and the majority of leads were placed by noncardiologists....... The procedure times were long and complications were frequent. The organization of emergency pacing is discussed, and we suggest that unless qualified physicians can establish transvenous pacing, the patients who need that should be transferred with transcutaneous pacing as back-up during transport...

  2. A comparison of groundwater investigation using temporary points versus permanent monitoring wells

    International Nuclear Information System (INIS)

    Thompson, N.T.

    1994-01-01

    Groundwater investigation within the environmental industry is most often conducted using permanent monitoring wells. A monitoring well, as the term suggests, is permanent to the extent that it is fixed in place to monitor groundwater quality in its immediate vicinity at any given time over the course of an environmental project. Because monitoring wells are relatively time consuming and expensive to construct, a minimum number of wells is normally installed as part of a single investigation event. The initial information obtained from monitoring wells could also be obtained from temporary groundwater sampling points. Temporary points generally are smaller in diameter than monitoring wells, are installed to provide a one time snap shot of the subsurface, and are removed at the completion of the investigation. Since temporary points are usually easier to install and less expensive than monitoring wells, more temporary points can be installed over a single investigation event and can often reduce or eliminate subsequent assessment(s). A brief discussion of temporary point installation and sampling is offered before considering two case studies within the context of the above advantages to temporary point installation. One case study focuses on vertical delineation of dissolved petroleum hydrocarbons, while the second case study discusses lateral delineation of light nonaqueous phase liquid (LNAPL)

  3. Efficacy of a dexamethasone-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt: an experimental study in a swine model

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Korea University Guro Hospital, Seoul (Korea, Republic of); Oh, Joo Hyeogn; Park, Young Koo [Kyung Hee University Hospital, Seoul (Korea, Republic of); Song, Ho Young [University of Ulsan, College of Medicine, Seoul (Korea, Republic of); Park, Sang Joon [Hallym University, College of Medicine, Seoul (Korea, Republic of); Yuk, Sun Hong [Hannam University, Daejeon (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM)-eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic shunt tract (TIPS) of a swine. Fifteen stents were constructed using 0.15 mm-thick nitinol wire; they were 60 mm in length and 10 mm in diameter. The metallic stents were then classified into three types; type 1 and 2 was coated with the mixture of 12% and 20%, respectively, of DM solution and polyurethane (PU), while type 3 was a bare stent that was used for control study. In fifteen swine, each type of stent was implanted in the TIPS tract of 5 swine, and each animal was sacrificed 2 weeks after TIPS creation. The proliferation of the pseudointima was evaluated both on follow-up portogram and pathologic examination. One TIPS case, using the type 1 stent, and two TIPS cases, using the type 2 stent, maintained their luminal patency while the others were all occluded. On the histopathologic analysis, the mean of the maximum pseudointimal hyperplasia was expressed as the percentage of the stent radius that was patent, and these values were 51.2%, 50% and 76% for the type 1, 2, and 3 stents, respectively. The DM-eluting stent showed a tendency to reduce the development of pseudointimal hyperplasia in the TIPS tract of a swine model with induced-portal hypertension.

  4. Creating a More Responsive and Seamless Refugee Protection System: The Scope, Promise and Limitations of US Temporary Protection Programs

    Directory of Open Access Journals (Sweden)

    Donald Kerwin

    2014-04-01

    , although the United States has never limited TPS to sub-state groups. TPS does not cover persons from designated states who arrive following the effective date of the designation, even those who fled great peril. TPS recipients cannot petition for the admission of close family members. In addition, TPS cannot be granted to persons in substantial need of protection from undesignated states.  Like refugees and asylees, TPS recipients receive work authorization. Unlike refugees or asylees, they are not eligible for resettlement benefits or deemed “qualified” for most federal public benefit programs. They can apply for political asylum and immigration benefits. However, TPS does not, in itself, lead to permanent status or other durable solutions. Beyond TPS, the executive branch can exercise its discretion not to remove persons who fall outside its law enforcement priorities, including persons who might otherwise suffer violence, extraordinary hardship, or death at home.  This paper outlines international standards for the design and operation of temporary protection programs, describes the US refugee protection program writ large, and identifies gaps in protection. It recommends that Congress create a non-immigrant “protection” visa for non-citizens who are at substantial risk of persecution, danger, or harm in their home or host countries, and that DHS expand its use of parole for de facto refugees and individuals in refugee-like situations. It also argues that the United States should prioritize the reconstruction and development of TPS-designated states and work to establish regional migration and development agreements covering North America, Central America and the Caribbean.Congress should also pass legislation to extend LPR status to long-term recipients of temporary protection.  In particular, it should advance the “registry” date to January 1, 1999 (which would provide LPR status to most non-citizens in the country since that date and it should

  5. 20 CFR 655.1301 - Applications for temporary employment certification in agriculture.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Applications for temporary employment certification in agriculture. 655.1301 Section 655.1301 Employees' Benefits EMPLOYMENT AND TRAINING... Applications for temporary employment certification in agriculture. (a) Application filing requirements. (1) An...

  6. Personal use of hair dyes and temporary black tattoos in Copenhagen hairdressers.

    Science.gov (United States)

    Hansen, Henriette S; Johansen, Jeanne D; Thyssen, Jacob P; Linneberg, Allan; Søsted, Heidi

    2010-06-01

    Hairdressers are occupationally and personally exposed to hair dye substances and adverse reactions from the skin are well known. Currently, little is known about personal exposure to hair dye ingredients and temporary black tattoos. To investigate hairdressers' professional and personal risk exposures and to compare the frequency of temporary tattoos among hairdressers and subjects from the general population. A questionnaire was sent to 1679 Copenhagen hairdressers and 1063 (63.3%) responded; 3471 subjects from the general population in Copenhagen were asked about temporary black tattoos. Of the female hairdressers, 38.3% had coloured hair within the previous week. Adverse skin reactions to own hair dye were reported in 29.5%. In the hairdresser population, no significant association was observed between self-reported adverse skin reactions to hair dye and having had a temporary black tattoo when adjusted for sex, age, and atopy. A total of 19.0% of hairdressers (43.5% of apprentices) and 6.3% of participants from the general population had ever had a temporary black tattoo performed at one point. There were no differences in frequency of eczema after temporary tattooing between hairdressers and subjects in the general population. Almost all hairdressers (99.2%) used gloves for hair colouring, 51% for high/low lighting, 39.6% for perming and 21.1% used gloves for shampooing. In conclusion, skin reactions to hair colour are frequent among Copenhagen hairdressers. Temporary black tattoos were more frequent among hairdressers than in a sample of the general population and increased with decreasing age.

  7. 75 FR 11627 - Order Granting Temporary Exemptions From Certain Government Securities Act Provisions and...

    Science.gov (United States)

    2010-03-11

    ... DEPARTMENT OF THE TREASURY Order Granting Temporary Exemptions From Certain Government Securities... Department of the Treasury (Treasury) is granting temporary exemptions from certain Government Securities Act...).pdf. \\8\\ 75 FR 4626, January 28, 2010 Order Granting a Temporary Exemption from Certain Government...

  8. Re-design, re-use and recycle of temporary houses

    Energy Technology Data Exchange (ETDEWEB)

    Arslan, Hakan [Department of Construction, Faculty of Technical Education, University of Abant Izzet Baysal, Duzce 81100 (Turkey)

    2007-01-15

    Disasters are recurring to global problems, which results in homelessness. The affected region had economical, environmental and social problems as well. In relief and reconstruction phases, the need for integrated management appeared in order to use the national sources actively and productively. Especially housing implementations had an important role for future development of the affected region. For accelerating the reconstruction of the region and forming a sustainable community, which maintains itself socially, environmentally and economically over time; energy usage for construction should be kept to a minimum. Past research in Turkey shows that the cost of temporary houses (to be used as the short term shelter) had a ratio of 10-15% of the total expenses of whole construction activity. For saving money and protecting the environment and conserving scarce resources, the affected region must consider the option of temporary houses to meet their short and long-term need during the reconstruction process. After the end of usage, temporary houses should be able to be re-used for the same or new function. This study is a test of re-design and re-use of a temporary housing site; by using recycled materials, minimum energy and voluntary participation so that this site can finally become a permanent housing site. (author)

  9. Multiple Institutional Logics in Inter-Institutional Temporary Organizations

    DEFF Research Database (Denmark)

    Pemsel, Sofia; Söderlund, Jonas

    for the planning and construction of a new super hospital in the capital of Sweden. Our empirical data demonstrates the important role institutional logics contribute with in understanding logics behind actions as well as emerging conflicts in practice throughout the project process. The paper identifies four......The idea of multiple institutional logics currently draws more and more attention as many organizational actors are forced to operate in ever more complex, temporary and vivid collaborations. We draw on findings from a unique case study of a temporary organization that carried the responsibility...

  10. Temporary hyperthyroidism (hypertriiodothyroninemia) to be evoked by stress

    International Nuclear Information System (INIS)

    Ehni, A.; Kampmann, H.

    1982-01-01

    From patients of intensive care unit suffering from acute myocardial infarction, decompensated hypertension with left heart insufficiency, severe coronary heart disease, pulmonary infarction, cerebral ischemia 102 were selected with suspicion of hyperthyroidism because of clinical signs. 12 patients fulfilled the criteria of temporary hyperthyroidism, 6 patients revealed persistent hyperthyroidism. Excluding other causes for evoked hyperthyroidism as common etiological factor psychogenic stress is discussed. It is concluded, that increased thyroid hormone concentration in patients of intensive care units should be controlled within a short time in order to delineate temporary hyperthyroidism against permanent hyperthyroidism. (orig.) [de

  11. Temporary hyperthyroidism (hypertriiodothyroninemia) to be evoked by stress

    Energy Technology Data Exchange (ETDEWEB)

    Ehni, A.; Kampmann, H.

    1982-10-01

    From patients of intensive care unit suffering from acute myocardial infarction, decompensated hypertension with left heart insufficiency, severe coronary heart disease, pulmonary infarction, cerebral ischemia 102 were selected with suspicion of hyperthyroidism because of clinical signs. 12 patients fulfilled the criteria of temporary hyperthyroidism, 6 patients revealed persistent hyperthyroidism. Excluding other causes for evoked hyperthyroidism as common etiological factor psychogenic stress is discussed. It is concluded, that increased thyroid hormone concentration in patients of intensive care units should be controlled within a short time in order to delineate temporary hyperthyroidism against permanent hyperthyroidism.

  12. Temporary work for children of members of the personnel

    CERN Multimedia

    2007-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 11 June to 14 September 2007 inclusive, a limited number of temporary jobs at CERN (normally unskilled work of a routine nature) will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1663.- for this period. Candidates should apply via the HR Department's electronic recruitment system (E-rt): https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=5466 Completed application forms must be returned to this service by 13 April 2007 at the latest. The results of the selection will be available on 11 May 200...

  13. Temporary work for children of members of the personnel

    CERN Multimedia

    2007-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 11 June to 14 September 2007 included, there will be a limited number of jobs for temporary work at CERN (normally unskilled work of routine nature) which will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1663.- for this period. Candidates should apply via HR department's electronic recruitment system (E-rt): https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=5466 Completed application forms must be returned to this service by 13 April 2007 at the latest. The results of the selection will be...

  14. Temporary work for children of members of the personnel

    CERN Multimedia

    2007-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 11 June to 14 September 2007 inclusive, a limited number of temporary jobs at CERN (normally unskilled work of a routine nature) will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1663.- for this period. Candidates should apply via the HR Department's electronic recruitment system (E-rt): https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=5466 Completed application forms must be returned to this service by 13 April 2007 at the latest. The results of the selection will be available on 11 May 2...

  15. Temporary work for children of members of the personnel

    CERN Multimedia

    2006-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 12 June to 15 September 2006 included, there will be a limited number of jobs for temporary work at CERN (normally unskilled work of routine nature) which will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1640.- for this period. Candidates should apply via HR department's electronic recruitment system (E-rt) : https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=4691 Completed application forms must be returned to this service by 17 April 2006 at the latest. The results of the selection will be...

  16. Temporary work for children of members of the personnel

    CERN Multimedia

    2006-01-01

    TO ALL MEMBERS OF THE PERSONNEL During the period 12 June to 15 September 2006 included, there will be a limited number of jobs for temporary work at CERN (normally unskilled work of routine nature) which will be made available to children of members of the personnel (i.e. anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of jobs available, no children who have previously worked at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1640.- for this period. Candidates should apply via HR department's electronic recruitment system (E-rt) : https://ert.cern.ch/browse_www/wd_pds?p_web_page_id=4691 Completed application forms must be returned to this service by 17 April 2006 at the latest. The results of the selection will be a...

  17. Quality of life from oncological patients with definitive and temporary colostomy

    Directory of Open Access Journals (Sweden)

    Renata Costa Fortes

    2012-09-01

    Full Text Available INTRODUCTION: Colorectal cancer is one of the most prevalent neoplasms in the western world. Colostomy, temporary or permanent, can be a serious limiting factor affecting the quality of life of oncological patients. OBJECTIVE: To compare the quality of life of oncological patients with definitive and temporary colostomy. METHODS: Descriptive cross-sectional study carried out at a public hospital in Brasilia, Federal District of Brazil. The study analyzed 39 patients with colorectal cancer, 76.9% males, sorted into two groups: definitive ostomy (n=26 and temporary ostomy (n=13. The World Health Organization Quality of Life (WHOQOL-bref questionnaire was used to assess the quality of life. Data were analyzed using Excel 2007 and Statistical Package for Social Sciences 19.0. RESULTS: 50% of definitive and 76.9% of temporary ostomy patients reported that the physical pain did not interfere in the affairs. 38.5% of definitive and 46.2% of temporary ostomy accepted their physical appearance. 46.2% of definitive and 53.8% of temporary ostomy reported good quality of life. 84.6% of definitive and 46.2% of temporary ostomy did not enjoy their life. 50% of definitive and 53.8% of temporary ostomy were satisfied with their sleep. 57.7% of definitive and 53.8% of temporary ostomy considered the environments as healthy. Over 70% of definitive and over 50% of temporary ostomy had financial constraints and were dissatisfied with leisure opportunities, respectively. 69.2% of definitive and 46.2% of temporary ostomy presented lower libido. 88.5% of definitive and 61.5% of temporary ostomy attended the church. CONCLUSION: The results showed that temporary ostomy patients suffer the same afflictions as the patients with definitive ostomy, equally affecting the quality of life of these patients.INTRODUÇÃO: O câncer colorretal é uma das neoplasias mais prevalentes no mundo ocidental. A colostomia, temporária ou definitiva, pode ser um sério limitador da

  18. 26 CFR 1.41-0T - Table of contents (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Table of contents (temporary). 1.41-0T Section 1... Credits Against Tax § 1.41-0T Table of contents (temporary). This section lists the table of contents for...) Election. (1) In general. (2) Time and manner of election. (3) Revocation. (4) Special rules for controlled...

  19. Estimating temporary and permanent stock price innovations on Croatian capital market

    Directory of Open Access Journals (Sweden)

    Tihana Škrinjarić

    2014-03-01

    Full Text Available This paper evaluates the size and duration of temporary and permanent stock price innovations on Croatian capital market in the structural VAR (vector autoregression framework with Blanchard and Quah (1989 decomposition. The purpose is to identify the effects of temporary price innovations in order to determine to which extent future stock prices can be predicted. Temporary components present in stock prices are explained throughout the mean-reversion hypothesis. This means that stock prices deviate from the fundamental values, but they will revert to their mean. In that way, to some extent, it is possible to predict future price movements. The results show that for the observed period from January 2000 to September 2013, temporary innovations account for only 2.62% of price variability over a two-year horizon. This means that forecasting the future movements of stock prices on Zagreb Stock Exchange is a difficult task.

  20. Schedules of Controlled Substances: Temporary Placement of 4-Fluoroisobutyryl Fentanyl into Schedule I. Temporary scheduling order.

    Science.gov (United States)

    2017-05-03

    The Administrator of the Drug Enforcement Administration is issuing this temporary scheduling order to schedule the synthetic opioid, N-(4-fluorophenyl)-N-(1-phenethylpiperidin-4-yl)isobutyramide (4-fluoroisobutyryl fentanyl or para-fluoroisobutyryl fentanyl), and its isomers, esters, ethers, salts and salts of isomers, esters, and ethers, into schedule I pursuant to the temporary scheduling provisions of the Controlled Substances Act. This action is based on a finding by the Administrator that the placement of 4-fluoroisobutyryl fentanyl into schedule I of the Controlled Substances Act is necessary to avoid an imminent hazard to the public safety. As a result of this order, the regulatory controls and administrative, civil, and criminal sanctions applicable to schedule I controlled substances will be imposed on persons who handle (manufacture, distribute, reverse distribute, import, export, engage in research, conduct instructional activities or chemical analysis, or possess), or propose to handle, 4-fluoroisobutyryl fentanyl.

  1. Environment - Borrow Area for Temporary Levee

    Data.gov (United States)

    Army Corps of Engineers, Department of the Army, Department of Defense — This data represents the location of a borrow site for construction materials used in temporary levee building during flood events. The footprint of these areas have...

  2. Temporary wetlands: Challenges and solutions to conserving a ‘disappearing’ ecosystem

    Science.gov (United States)

    Calhoun, Aram J.K.; Mushet, David M.; Bell, Kathleen P.; Boix, Dani; Fitzsimons, James A.; Isselin-Nondedeu, Francis

    2017-01-01

    Frequent drying of ponded water, and support of unique, highly specialized assemblages of often rare species, characterize temporary wetlands, such as vernal pools, gilgais, and prairie potholes. As small aquatic features embedded in a terrestrial landscape, temporary wetlands enhance biodiversity and provide aesthetic, biogeochemical, and hydrologic functions. Challenges to conserving temporary wetlands include the need to: (1) integrate freshwater and terrestrial biodiversity priorities; (2) conserve entire ‘pondscapes’ defined by connections to other aquatic and terrestrial systems; (3) maintain natural heterogeneity in environmental gradients across and within wetlands, especially gradients in hydroperiod; (4) address economic impact on landowners and developers; (5) act without complete inventories of these wetlands; and (6) work within limited or non-existent regulatory protections. Because temporary wetlands function as integral landscape components, not singly as isolated entities, their cumulative loss is ecologically detrimental yet not currently part of the conservation calculus. We highlight approaches that use strategies for conserving temporary wetlands in increasingly human-dominated landscapes that integrate top-down management and bottom-up collaborative approaches. Diverse conservation activities (including education, inventory, protection, sustainable management, and restoration) that reduce landowner and manager costs while achieving desired ecological objectives will have the greatest probability of success in meeting conservation goals.

  3. Temporary Workforce Planning with Firm Contracts: A Model and a Simulated Annealing Heuristic

    Directory of Open Access Journals (Sweden)

    Muhammad Al-Salamah

    2011-01-01

    Full Text Available The aim of this paper is to introduce a model for temporary staffing when temporary employment is managed by firm contracts and to propose a simulated annealing-based method to solve the model. Temporary employment is a policy frequently used to adjust the working hour capacity to fluctuating demand. Temporary workforce planning models have been unnecessarily simplified to account for only periodic hiring and laying off; a company can review its workforce requirement every period and make hire-fire decisions accordingly, usually with a layoff cost. We present a more realistic temporary workforce planning model that assumes a firm contract between the worker and the company, which can extend to several periods. The model assumes the traditional constraints, such as inventory balance constraints, worker availability, and labor hour mix. The costs are the inventory holding cost, training cost of the temporary workers, and the backorder cost. The mixed integer model developed for this case has been found to be difficult to solve even for small problem sizes; therefore, a simulated annealing algorithm is proposed to solve the mixed integer model. The performance of the SA algorithm is compared with the CPLEX solution.

  4. The underdilation of nitinol stents at TIPS implantation: Solution or illusion?

    Energy Technology Data Exchange (ETDEWEB)

    Mollaiyan, Ashkan [University Hospital, Department of Radiology, Hugstetterstrasse 55, 79106 Freiburg (Germany); Bettinger, Dominik [University Hospital, Department of Gastroenterology, Hugstetterstrasse 55, 79106 Freiburg (Germany); Berta-Ottenstein-Programme, Faculty of Medicine, University of Freiburg (Germany); Rössle, Martin, E-mail: Martin-Roessle@t-online.de [University Hospital, Department of Gastroenterology, Hugstetterstrasse 55, 79106 Freiburg (Germany); Praxiszentrum für Gastroenterologie, Bertoldstrasse 48, 79098 Freiburg (Germany)

    2017-04-15

    Purpose: This study investigates the behaviour of self-expanding nitinol stents at the time of TIPS-implantation and thereafter. Methods: Hundred consecutive patients with cirrhosis receiving a TIPS revision were included. The smallest stent diameter was measured radiologically immediately after implantation and before shunt revision. Accuracy of the measurement was assessed by comparing the nominal stent diameter with the largest stent diameter measured at the time of revision. Results: Pearson correlation between largest measured and nominal diameters was excellent (r = 0.952, p < 0.001) showing that measurements are accurate. At TIPS implantation all stents were markedly underdilated reaching only 76–92% of their nominal diameter. Smallest measured diameters were similar (8 mm) irrespective of the nominal diameter (8, 9, 10 mm) of the stent. In addition, smallest diameters of 10 mm stents were similar irrespective whether 8, 9 or 10 mm balloons were used. During a mean follow-up of 12.7 ± 17.8 months (median 3 months, range 1–81) stents expanded by 0.5–1.6 mm dependent on the nominal stent size (8, 9, 10 mm) and the grade of primary underdilation. No significant difference was found between Viatorr and bare stents. Conclusions: At TIPS-implantation, the compliance of the surrounding tissue predominantly determines the stent diameter. The nominal size of the stent or the dilatation balloon has little influence. Accurate adjustment of a desired pressure gradient is, therefore, not possible. During follow-up, stents expand towards their nominal diameter questioning the usefulness of underdilation.

  5. The underdilation of nitinol stents at TIPS implantation: Solution or illusion?

    International Nuclear Information System (INIS)

    Mollaiyan, Ashkan; Bettinger, Dominik; Rössle, Martin

    2017-01-01

    Purpose: This study investigates the behaviour of self-expanding nitinol stents at the time of TIPS-implantation and thereafter. Methods: Hundred consecutive patients with cirrhosis receiving a TIPS revision were included. The smallest stent diameter was measured radiologically immediately after implantation and before shunt revision. Accuracy of the measurement was assessed by comparing the nominal stent diameter with the largest stent diameter measured at the time of revision. Results: Pearson correlation between largest measured and nominal diameters was excellent (r = 0.952, p < 0.001) showing that measurements are accurate. At TIPS implantation all stents were markedly underdilated reaching only 76–92% of their nominal diameter. Smallest measured diameters were similar (8 mm) irrespective of the nominal diameter (8, 9, 10 mm) of the stent. In addition, smallest diameters of 10 mm stents were similar irrespective whether 8, 9 or 10 mm balloons were used. During a mean follow-up of 12.7 ± 17.8 months (median 3 months, range 1–81) stents expanded by 0.5–1.6 mm dependent on the nominal stent size (8, 9, 10 mm) and the grade of primary underdilation. No significant difference was found between Viatorr and bare stents. Conclusions: At TIPS-implantation, the compliance of the surrounding tissue predominantly determines the stent diameter. The nominal size of the stent or the dilatation balloon has little influence. Accurate adjustment of a desired pressure gradient is, therefore, not possible. During follow-up, stents expand towards their nominal diameter questioning the usefulness of underdilation.

  6. Partitioning detectability components in populations subject to within-season temporary emigration using binomial mixture models.

    Directory of Open Access Journals (Sweden)

    Katherine M O'Donnell

    Full Text Available Detectability of individual animals is highly variable and nearly always < 1; imperfect detection must be accounted for to reliably estimate population sizes and trends. Hierarchical models can simultaneously estimate abundance and effective detection probability, but there are several different mechanisms that cause variation in detectability. Neglecting temporary emigration can lead to biased population estimates because availability and conditional detection probability are confounded. In this study, we extend previous hierarchical binomial mixture models to account for multiple sources of variation in detectability. The state process of the hierarchical model describes ecological mechanisms that generate spatial and temporal patterns in abundance, while the observation model accounts for the imperfect nature of counting individuals due to temporary emigration and false absences. We illustrate our model's potential advantages, including the allowance of temporary emigration between sampling periods, with a case study of southern red-backed salamanders Plethodon serratus. We fit our model and a standard binomial mixture model to counts of terrestrial salamanders surveyed at 40 sites during 3-5 surveys each spring and fall 2010-2012. Our models generated similar parameter estimates to standard binomial mixture models. Aspect was the best predictor of salamander abundance in our case study; abundance increased as aspect became more northeasterly. Increased time-since-rainfall strongly decreased salamander surface activity (i.e. availability for sampling, while higher amounts of woody cover objects and rocks increased conditional detection probability (i.e. probability of capture, given an animal is exposed to sampling. By explicitly accounting for both components of detectability, we increased congruence between our statistical modeling and our ecological understanding of the system. We stress the importance of choosing survey locations and

  7. Induction of osteogenic differentiation of adipose derived stem cells by microstructured nitinol actuator-mediated mechanical stress.

    Directory of Open Access Journals (Sweden)

    Sarah Strauß

    Full Text Available The development of large tissue engineered bone remains a challenge in vitro, therefore the use of hybrid-implants might offer a bridge between tissue engineering and dense metal or ceramic implants. Especially the combination of the pseudoelastic implant material Nitinol (NiTi with adipose derived stem cells (ASCs opens new opportunities, as ASCs are able to differentiate osteogenically and therefore enhance osseointegration of implants. Due to limited knowledge about the effects of NiTi-structures manufactured by selective laser melting (SLM on ASCs the study started with an evaluation of cytocompatibility followed by the investigation of the use of SLM-generated 3-dimensional NiTi-structures preseeded with ASCs as osteoimplant model. In this study we could demonstrate for the first time that osteogenic differentiation of ASCs can be induced by implant-mediated mechanical stimulation without support of osteogenic cell culture media. By use of an innovative implant design and synthesis via SLM-technique we achieved high rates of vital cells, proper osteogenic differentiation and mechanically loadable NiTi-scaffolds could be achieved.

  8. 30 CFR 816.14 - Casing and sealing of drilled holes: Temporary.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Casing and sealing of drilled holes: Temporary. 816.14 Section 816.14 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT...-SURFACE MINING ACTIVITIES § 816.14 Casing and sealing of drilled holes: Temporary. Each exploration hole...

  9. Do changes in regulation affect employment duration in temporary help agencies?

    DEFF Research Database (Denmark)

    Antoni, Manfred; Jahn, Elke

    2009-01-01

    The employment duration of workers in temporary help agencies is seen as an important indicator of their job quality. Most of the countries that regulate temporary agency employment do so to insure at least a minimal level of employment stability. Over the past three decades Germany has repeatedly...

  10. Management of malignant biliary obstruction: Technical and clinical results using an expanded polytetrafluoroethylene fluorinated ethylene propylene (ePTFE/FEP)-covered metallic stent after 6-year experience

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Orgera, Gianluigi; Bezzi, Mario; Rossi, Plinio; Allegritti, Massimiliano; Passariello, Roberto [University of Rome, Department of Radiological Sciences, Rome (Italy)

    2008-05-15

    To evaluate the efficacy and safety of an expanded polytetrafluoroethylene-fluorinated ethylene-propylene (ePTFE/FEP)-covered metallic stent in the management of malignant biliary obstruction. Eighty consecutive patients with malignant common bile duct strictures were treated by placement of 83 covered metallic stents. The stent-graft consists of an inner ePTFE/FEP lining and an outer supporting structure of nitinol wire. Clinical evaluation, assessment of serum bilirubin and liver enzyme levels were analyzed before biliary drainage, before stent-graft placement and during the follow-up period at 1, 3, 6, 9 and 12 months. Technical success was obtained in all cases. After a mean follow-up of 6.9{+-}4.63 months, the 30-day mortality rate was 14.2%. Survival rates were 40% and 20.2% at 6 and 12 months, respectively. Stent-graft patency rates were 95.5%, 92.6% and 85.7% at 3, 6 and 12 months, respectively. Complications occurred in five patients (6.4%); among these, acute cholecystitis was observed in three patients (3.8%). A stent-graft occlusion rate of 9% was observed. The percentage of patients undergoing lifetime palliation (91%) and the midterm patency rate suggest that placement of this ePTFE/FEP-covered stent-graft is safe and highly effective in achieving biliary drainage in patients with malignant strictures of the common bile duct. (orig.)

  11. 77 FR 63835 - Office of the Chief Information Officer; Submission for OMB Review; Temporary Contractor...

    Science.gov (United States)

    2012-10-17

    ... of the Chief Information Officer; Submission for OMB Review; Temporary Contractor Information... information collection requirement regarding temporary contractor information worksheet. A notice was... for temporary contractors as a result of the American Recovery and Reinvestment Act of 2009 (Public...

  12. 19 CFR 12.104f - Temporary disposition of materials and articles.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Temporary disposition of materials and articles... SECURITY; DEPARTMENT OF THE TREASURY SPECIAL CLASSES OF MERCHANDISE Cultural Property § 12.104f Temporary... museum or other cultural or scientific institution in the U.S. if he finds that sufficient safeguards...

  13. 29 CFR 4.176 - Payment of fringe benefits to temporary and part-time employees.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Payment of fringe benefits to temporary and part-time... to temporary and part-time employees. (a) As set forth in § 4.165(a)(2), the Act makes no distinction, with respect to its compensation provisions, between temporary, part-time, and full-time employees...

  14. 26 CFR 1.6031(b)-2T - REMIC reporting requirements (temporary). [Reserved

    Science.gov (United States)

    2010-04-01

    ... requirements (temporary). [Reserved] ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false REMIC reporting requirements (temporary). [Reserved] 1.6031(b)-2T Section 1.6031(b)-2T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...

  15. Temporary Decompression in Critically Ill Patients: Retrospective Comparison of Ileostomy and Colostomy.

    Science.gov (United States)

    Lin, Zhi-Liang; Yu, Wen-Kui; Shi, Jia-Liang; Chen, Qi-Yi; Tan, Shan-Jun; Li, Ning

    2014-05-01

    In critically ill patients, gastrointestinal function plays an important role in multiple organ dysfunction syndrome. Patients suffering from acute lower gastrointestinal dysfunction need to be performed a temporary fecal diversion after the failure of conservative treatment. This study aims to determine which type of fecal diversion is associated with better clinical outcomes in critically ill patients. Data of critically ill patients requiring surgical decompression following acute lower gastrointestinal dysfunction between January 2008 and June 2013 were retrospectively analyzed. Comparison was made between ileostomy group and colostomy group regarding the stoma-related complications and the recovery after stoma creation. 63 patients consisted of temporary ileostomy group (n = 35) and temporary colostomy group (n = 28) were included in this study. First bowel movement and length of enteral nutrition intolerance after fecal diversion were both significantly shorter in the ileostomy group than in the colostomy group (1.70 ± 0.95 vs. 3.04 ± 1.40; p colostomy group. Both procedures provide an effective defunctioning of the distant gastrointestinal tract with a low complication incidence. We prefer a temporary ileostomy to temporary colostomy for acute lower gastrointestinal dysfunction in critically ill patients.

  16. 26 CFR 1.103(n)-6T - Determinations of population (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Determinations of population (temporary). 1.103....103(n)-6T Determinations of population (temporary). Q-1: What is the proper method for determining population? A-1: All determinations of population must be made with respect to any calendar year on the basis...

  17. Expression of TGF-β in Fractures Fixed by Nitinol Swan-like Memory Compressive Connectors

    Science.gov (United States)

    Li, M.; Zhang, C. C.; Xu, S. G.; Fu, Q. G.

    2011-07-01

    In this article, the effect of internal fixation of a Nitinol swan-like memory compressive connector (SMC) on the temporal expression of transforming growth factor-β (TGF-β) at fracture sites is evaluated. Specimens were collected from 35 New Zealand rabbits modeled for bilateral humeral fracture fixed with either SMC or stainless dynamic compression plate (DCP). Five rabbits each were killed at day 1, 3, 7, 14, 21, 28, and 56. The local positive staining potency, positive area ratio, and positive index of TGF-β were measured using an immunohistochemistry approach (EnVision) in combination with a computerized image analysis system. TGF-β staining was seen in mesenchymal cells, osteoblasts, chondrocytes, and in the extracellular matrix of fractures fixed in both the SMC and the DCP samples without a significant difference in staining at both the early stages (days 1 and 3) and day 56. A higher TGF-β content was observed in the fractures fixed with SMC when compared to that of DCP from day 7 to 28. As a conclusion, TGF-β is highly expressed in fractures fixed with SMC during chondrogenesis stage and entochondrostosis stage. Finally, the mechanism of how SMC promoting synthesis and secretion of TGF-β in the process of fracture healing has been discussed.

  18. The post-disaster temporary dwelling: Fundamentals of provision, design and construction

    Directory of Open Access Journals (Sweden)

    Adham Hany Abulnour

    2014-04-01

    In employing the adopted methodology of research, the paper commences by a literature review which aims to set the basic terms and concepts. Consecutively, the paper sets the basic foundations to the provision, design and construction of temporary dwellings. The discussion widens in scope to analyze the qualitative aspects related to the management of temporary dwellings. This part constitutes the basic guidelines which support the following discussions made in the paper. As the subjects keep on unfolding, the concept of contextualization is elaborated with the issue of ‘sensitivity’ to local conditions and circumstances as a prime focus. The paper finally proceeds to analyzing a number of important qualitative aspects related to the design and construction of temporary dwellings with a special focus on temporary houses. The discussion is emphasized through examining several examples to clarify the various needs and implications of the qualitative aspects under investigation. The overall research outcome of the paper is expressed in a number of findings and recommendations in correspondence to the paper structure.

  19. 78 FR 24239 - Temporary Mailing Promotion

    Science.gov (United States)

    2013-04-24

    ... POSTAL REGULATORY COMMISSION [Docket No. R2013-6; Order No. 1702] Temporary Mailing Promotion... offering a Technology Credit Promotion. This notice informs the public of the Postal Service's filing and... changes associated with offering a Technology Credit Promotion.\\1\\ The promotion is planned to begin on...

  20. Partitioning detectability components in populations subject to within-season temporary emigration using binomial mixture models.

    Science.gov (United States)

    O'Donnell, Katherine M; Thompson, Frank R; Semlitsch, Raymond D

    2015-01-01

    Detectability of individual animals is highly variable and nearly always binomial mixture models to account for multiple sources of variation in detectability. The state process of the hierarchical model describes ecological mechanisms that generate spatial and temporal patterns in abundance, while the observation model accounts for the imperfect nature of counting individuals due to temporary emigration and false absences. We illustrate our model's potential advantages, including the allowance of temporary emigration between sampling periods, with a case study of southern red-backed salamanders Plethodon serratus. We fit our model and a standard binomial mixture model to counts of terrestrial salamanders surveyed at 40 sites during 3-5 surveys each spring and fall 2010-2012. Our models generated similar parameter estimates to standard binomial mixture models. Aspect was the best predictor of salamander abundance in our case study; abundance increased as aspect became more northeasterly. Increased time-since-rainfall strongly decreased salamander surface activity (i.e. availability for sampling), while higher amounts of woody cover objects and rocks increased conditional detection probability (i.e. probability of capture, given an animal is exposed to sampling). By explicitly accounting for both components of detectability, we increased congruence between our statistical modeling and our ecological understanding of the system. We stress the importance of choosing survey locations and protocols that maximize species availability and conditional detection probability to increase population parameter estimate reliability.

  1. Ripening of clayey dredged sediments during temporary upland disposal, A Bioremediation technique.

    NARCIS (Netherlands)

    Vermeulen, J.; Grotenhuis, J.T.C.; Joziasse, J.; Rulkens, W.H.

    2003-01-01

    Background and Goal. In the Netherlands about 40 million m3 of sediment has to be dredged annually for both maintenance and environmental reasons. Temporary upland disposal is the most widely adopted alternative for dredged sediments worldwide. For good management of temporary disposal sites,

  2. Failure of communication and capture: The perils of temporary unipolar pacing system.

    Science.gov (United States)

    Sahinoglu, Efe; Wool, Thomas J; Wool, Kenneth J

    2015-06-01

    We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  3. Managing Conflict in Temporary Management Systems

    Science.gov (United States)

    Wilemon, David L.

    1973-01-01

    As organizational tasks have grown more complex, several innovative temporary management systems such as matrix management have been developed. The Apollo space program has been an important contribution to the development of matrix management techniques. Discusses the role of conflict within the matrix, its determinants, and the process of…

  4. 40 CFR 82.65 - Temporary exemptions.

    Science.gov (United States)

    2010-07-01

    ...) PROTECTION OF STRATOSPHERIC OZONE Ban on Nonessential Products Containing Class I Substances and Ban on Nonessential Products Containing or Manufactured With Class II Substances § 82.65 Temporary exemptions. (a) Any... January 1, 1996. (e) Any person selling or distributing, or offering to sell or distribute, any product...

  5. Physical performance deterioration of temporary housing residents after the Great East Japan Earthquake

    Directory of Open Access Journals (Sweden)

    Takeaki Ishii

    2015-01-01

    We revealed that standing stability was impaired among elderly temporary housing residents 1.5 years after the disaster. Disaster responders should take into account the health risks associated with living in temporary housing.

  6. 38 CFR 21.6001 - Temporary vocational training program for certain pension recipients.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Temporary vocational training program for certain pension recipients. 21.6001 Section 21.6001 Pensions, Bonuses, and Veterans... Program of Vocational Training for Certain New Pension Recipients General § 21.6001 Temporary vocational...

  7. Temporary Authorizations at Permitted Waste Management Facilities

    Science.gov (United States)

    This rule under the Code of Federal Regulations (CFR) provides EPA with the authority to grant a permittee temporary authorization, without prior public notice and comment, to conduct activities necessary to respond promptly to changing conditions.

  8. Alternativa técnica no tratamento endovascular dos aneurismas da artéria poplítea A technical alternative for the endovascular treatment of popliteal artery aneurysms

    Directory of Open Access Journals (Sweden)

    Marcelo Ferreira

    2008-03-01

    Full Text Available O aneurisma de artéria poplítea é relativamente raro, porém representa cerca de 85% de todos os aneurismas arteriais periféricos. Apresenta-se geralmente com um quadro de complicação isquêmica e elevado risco de perda do membro acometido. Em função disso, preconiza-se seu tratamento eletivo, atualmente realizado com resultados satisfatórios pela técnica endovascular. Relatamos nossa experiência com a utilização do stent de nitinol auto-expansível revestido com PTFEe - Fluency (Bard, Alemanha, reforçado internamente com o stent de nitinol auto-expansível Zilver (Cook, EUA no tratamento de um aneurisma de artéria poplítea.Popliteal artery aneurysm is relatively rare, but represents around 85% of all peripheral arterial aneurysms. It is usually presented with ischemic complication and high risk of limb loss. For that reason, its elective treatment is indicated and currently carried through with satisfactory results using endovascular techniques. We describe our experience with the use of an ePTFE-covered nitinol self-expandable stent graft - Fluency (Bard, Germany, reinforced internally with the nitinol self-expandable Zilver stent (Cook, USA for the treatment of a popliteal artery aneurism.

  9. Diatom-based models for inferring water chemistry and hydrology in temporary depressional wetlands

    CSIR Research Space (South Africa)

    Riato, L

    2017-08-01

    Full Text Available Information on the response of temporary depressional wetland diatoms to human-induced disturbances is a limited and important component for the development of temporary wetland biological assessments in human-modified landscapes. Establishing a...

  10. 26 CFR 1.892-6T - Income of international organizations (temporary regulations).

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Miscellaneous Provisions § 1.892-6T Income of international organizations (temporary regulations). (a) Exempt from tax. Subject to the provisions of section 1 of the... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Income of international organizations (temporary...

  11. 77 FR 76854 - Temporary Rule Regarding Principal Trades With Certain Advisory Clients

    Science.gov (United States)

    2012-12-31

    ... 3235-AL28 Temporary Rule Regarding Principal Trades With Certain Advisory Clients AGENCY: Securities... transactions with certain of their advisory clients. The amendment extends the date on which rule 206(3)- 3T... releases used RIN 3235-AJ96. (See Temporary Rule Regarding Principal Trades with Certain Advisory Clients...

  12. Zooplankton resting egg banks in permanent and temporary tropical aquatic systems

    Directory of Open Access Journals (Sweden)

    Luciana Rabelo Araújo

    Full Text Available AIM: We evaluated zooplankton resting egg banks and active communities in five coastal lagoons and in five temporary pools, aiming to compare the active and the dormant communities in such environments. As they differ in hydroperiod, we expected that pools present richer resting egg banks in comparison to those found in lagoons. METHODS: Zooplankton community was sampled twice in 2006 (lagoons and in 2010 (pools and resting egg banks were sampled once in December 2007 (lagoons and in May 2010 (pools. Resting eggs were isolated from the sediment by applying the sugar flotation method. RESULTS: In opposition to our expectation, species richness in the resting egg banks of pools did not differ from those of lagoons. Additionally, no difference was found between the active and the dormant zooplankton communities in each water body for both temporary and permanent environments. However, similarity between active and dormant communities was greater in permanent environments than it was in temporary environments. CONCLUSIONS: It seems that the diapause strategy observed in certain tropical zooplankton populations cannot be predicted based on the awareness of the environment type (permanent or temporary, since hatching cues may be species-specific.

  13. PEEK (polyether-ether-ketone)-coated nitinol wire: Film stability for biocompatibility applications

    Energy Technology Data Exchange (ETDEWEB)

    Sheiko, Nataliia [Institut Charles Sadron, C.N.R.S. UPR 22, Université de Strasbourg, 23 rue du Loess, BP 84047, 67034 Strasbourg Cedex 2 (France); Kékicheff, Patrick, E-mail: patrick.kekicheff@ics-cnrs.unistra.fr [Institut Charles Sadron, C.N.R.S. UPR 22, Université de Strasbourg, 23 rue du Loess, BP 84047, 67034 Strasbourg Cedex 2 (France); Marie, Pascal; Schmutz, Marc; Jacomine, Leandro [Institut Charles Sadron, C.N.R.S. UPR 22, Université de Strasbourg, 23 rue du Loess, BP 84047, 67034 Strasbourg Cedex 2 (France); Perrin-Schmitt, Fabienne [Faculté de Médecine, INSERM, UMR-S 1121, “Biomaterials and Bioengineering”, Université de Strasbourg, 11 rue Humann, 67085 Strasbourg Cedex (France)

    2016-12-15

    Highlights: • A thin (12 μm) homogeneous PEEK film without any defects or voids is deposited on NiTi wires. • The coating remains stable in biological environment with negligible Ni ion release and no cytotoxicity. • Large pressure (>2 GPa) can only disrupt the coating film as shown by nanoscratch tests. • Coated spring wires sustain mechanical stress in continuous cycles of axial compression/stretching for >7 million cycles. - Abstract: High quality biocompatible poly-ether-ether-ketone (PEEK) coatings were produced on NiTi shape memory alloy wires using dipping deposition from colloidal aqueous PEEK dispersions after substrate surface treatment. The surface morphology and microstructure were investigated by Scanning Electron Microscopy at every step of the process from the as-received Nitinol substrate to the ultimate PEEK-coated NiTi wire. Nanoscratch tests were carried out to access the adhesive behavior of the polymer coated film to the NiTi. The results indicate that the optimum process conditions in cleaning, chemical etching, and electropolishing the NiTi, were the most important and determining parameters to be achieved. Thus, high quality PEEK coatings were obtained on NiTi wires, straight or curved (even with a U-shape) with a homogeneous microstructure along the wire length and a uniform thickness of 12 μm without any development of cracks or the presence of large voids. The biocompatibility of the PEEK coating film was checked in fibrobast cultured cells. The coating remains stable in biological environment with negligible Ni ion release, no cytotoxicity, and no delamination observed with time.

  14. PEEK (polyether-ether-ketone)-coated nitinol wire: Film stability for biocompatibility applications

    International Nuclear Information System (INIS)

    Sheiko, Nataliia; Kékicheff, Patrick; Marie, Pascal; Schmutz, Marc; Jacomine, Leandro; Perrin-Schmitt, Fabienne

    2016-01-01

    Highlights: • A thin (12 μm) homogeneous PEEK film without any defects or voids is deposited on NiTi wires. • The coating remains stable in biological environment with negligible Ni ion release and no cytotoxicity. • Large pressure (>2 GPa) can only disrupt the coating film as shown by nanoscratch tests. • Coated spring wires sustain mechanical stress in continuous cycles of axial compression/stretching for >7 million cycles. - Abstract: High quality biocompatible poly-ether-ether-ketone (PEEK) coatings were produced on NiTi shape memory alloy wires using dipping deposition from colloidal aqueous PEEK dispersions after substrate surface treatment. The surface morphology and microstructure were investigated by Scanning Electron Microscopy at every step of the process from the as-received Nitinol substrate to the ultimate PEEK-coated NiTi wire. Nanoscratch tests were carried out to access the adhesive behavior of the polymer coated film to the NiTi. The results indicate that the optimum process conditions in cleaning, chemical etching, and electropolishing the NiTi, were the most important and determining parameters to be achieved. Thus, high quality PEEK coatings were obtained on NiTi wires, straight or curved (even with a U-shape) with a homogeneous microstructure along the wire length and a uniform thickness of 12 μm without any development of cracks or the presence of large voids. The biocompatibility of the PEEK coating film was checked in fibrobast cultured cells. The coating remains stable in biological environment with negligible Ni ion release, no cytotoxicity, and no delamination observed with time.

  15. Evaluation of color stability of different temporary restorative materials

    Directory of Open Access Journals (Sweden)

    José Vitor Quinelli Mazaro

    Full Text Available AbstractIntroductionTemporary restorative materials are widely used, however, little is know about their color stability.Objectiveto evaluate the color stability of the following temporary restorative materials: acrylic and bis-acrylic resins after immersion in pigmenting solutions for different periods of storage.Material and methodFour materials were tested (Dêncor/Clássico, Protemp 4/3M ESPE; Structur 2 SC/Voco; Luxatemp AM Plus/DMG and 30 test specimens (15 mm in diameter and 2 mm thick per material were fabricated. They were divided according to the storage medium (artificial saliva, saliva + cola type soda, and saliva + coffee and storage time intervals (2, 5, 7 and 15 days. Color measurements were made before and after immersions, with use of a spectrophotometer, by means of the CIE L*a*b* system. The data were analyzed by the analysis of variance and the Tukey Test, at a level of significance of 5%.ResultAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001. When bis-acrylic resins were compared no significant difference was observed between the resins Structur and Luxatemp (p=0.767. As regards solutions tested, coffee showed the highest color change values (p<0.001, and the longer the storage time interval, the greater was the color change in all the temporary restorative materials analyzed (p<0.001.ConclusionAcrylic resin presented greater color stability in comparison with bis-acrylic resins (p<0.001. Coffee caused the greatest color change, and immersion time was determinant in color stability of the temporary materials analyzed.

  16. Failure of communication and capture: The perils of temporary unipolar pacing system

    Directory of Open Access Journals (Sweden)

    Efe Sahinoglu, BChE

    2015-06-01

    Full Text Available We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  17. Temporary workers in the nuclear power industry: implications for the waste management program

    International Nuclear Information System (INIS)

    Melville, M.H.

    1984-01-01

    The employment of large number of temporary workers has become a growing and permanent characteristic of the nuclear power industry. In order to stay within the limits governing individual exposure to radiation in the workplace, the occupational risk has been spread among a larger segment of the population. Temporary workers, who make up one-third of the industry's work force, bear a disproportionate share of half the total annual occupational radiation dose. At issue is whether temporary workers should be grouped with the public at large or with the nuclear industry's work force, whose maximum limits are at least 10 times higher. This issue is relevant at a time when the search for a way to manage the mounting radioactive wastes will increase both the permanent and temporary work force. 44 references, 4 figures, 4 tables

  18. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    International Nuclear Information System (INIS)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis; Padayachee, Soundrie; Karunanithy, Narayan; Ahmed, Irfan; Zayed, Hany; Katsanos, Konstantinos

    2015-01-01

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery

  19. Use of a New Hybrid Heparin-Bonded Nitinol Ring Stent in the Popliteal Artery: Procedural and Mid-term Clinical and Anatomical Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Parthipun, Aneeta; Diamantopoulos, Athanasios; Kitrou, Panagiotis [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Padayachee, Soundrie [King’s Health Partners, Department of Ultrasonic Angiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Karunanithy, Narayan; Ahmed, Irfan [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Zayed, Hany [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: konstantinos.katsanos@gstt.nhs.uk, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeTo report the immediate and mid-term clinical and anatomical outcomes of a novel, hybrid, heparin-bonded, nitinol ring stent (TIGRIS; Gore Medical) when used for the treatment of lesions located in the popliteal artery.Materials and MethodsThis was a prospective single-centre registry. Patients eligible for inclusion were individuals suffering from symptomatic popliteal arterial occlusive disease (Rutherford–Becker stage 3–6; P1–P3 segments) and treated with placement of the TIGRIS stent(s). Patients were prospectively scheduled for clinical review and duplex ultrasound follow-up after 6 and 12 months. Outcome measures included immediate technical success, primary vessel patency, in-stent binary restenosis (evaluable by Duplex at 50 % threshold; PSVR > 2.0), freedom from target lesion revascularization (TLR) and amputation-free survival (AFS) estimated by Kaplan–Meier (K–M) survival analysis. Cox proportional-hazards regression analysis was also performed to adjust for confounders and search for independent predictors of outcomes.ResultsFrom August 2012 to March 2014, a total of 54 popliteal TIGRIS stents were implanted in 50 limbs of 48 patients (27 men and 21 women; mean age 76.0 ± 1.7 years). Median Rutherford–Becker stage was five at baseline and 37/50 (74.0 %) were chronic total occlusions. Technical success was achieved in all cases (100 %). Stented lesion length was 114.2 ± 36.9 mm (range 6–20 cm). Median follow-up was 11.8 ± 0.8 months. After 12 months, primary patency of the TIGRIS stent was 69.5 ± 10.2 % with an 86.1 ± 5.9 % freedom from TLR and 87 ± 5.0 % AFS (K–M estimates).ConclusionThe TIGRIS hybrid heparin-bonded nitinol ring stent is a safe and effective endovascular option for complex occlusive disease of the popliteal artery.

  20. 'And when a certain health issue happen, they try to cover it': Stakeholder perspectives on the health of temporary foreign workers and their families.

    Science.gov (United States)

    Salami, Bukola; Hegadoren, Kathleen; Kirova, Anna; Meherali, Salima; Nsaliwa, Christina; Chiu, Yvonne

    2018-01-01

    This study examines stakeholders' perspectives on the health and well-being of temporary foreign workers (TFWs) and their families in Alberta, Canada. We used a critically informed qualitative methodology. We interviewed 13 stakeholders, including service providers and policy makers. Stakeholders involved in providing services to TFWs perceived that the workers experience (1) barriers in accessing mental health services, (2) mental health challenges, (3) family health challenges, (4) occupational health challenges, and (5) income and social status as a social determinant of health. Immigration and class status intersect to influence the health of this vulnerable population in Canada.

  1. Exits from Temporary Jobs in Europe: A Competing Risks Analysis

    DEFF Research Database (Denmark)

    D'Addio, Anna Christina; Rosholm, Michael

    2005-01-01

    We study transitions out of temporary jobs using the waves 1994-1999 of the European Community Household Panel applying a discrete time duration model. Specifically, we use a multinomial logitmodel distinguishing between exits into permanent employment and non-employment. Two different specificat......We study transitions out of temporary jobs using the waves 1994-1999 of the European Community Household Panel applying a discrete time duration model. Specifically, we use a multinomial logitmodel distinguishing between exits into permanent employment and non-employment. Two different...

  2. Designing Temporary Systems: Exploring Local School Improvement Intentions in the Swedish Context

    Science.gov (United States)

    Nordholm, Daniel; Blossing, Ulf

    2014-01-01

    This article targets local school improvement in Sweden and temporary systems as a model to organize improvement work. These data are based on a qualitative case study of teacher groups constituting a temporary system representing the different subjects in comprehensive school in a medium-sized urban municipality. A total of eight interviews were…

  3. 29 CFR 1601.23 - Preliminary or temporary relief.

    Science.gov (United States)

    2010-07-01

    ..., or political subdivision. (b) In a case involving a government, governmental agency, or political... private individuals from exercising their rights to seek temporary or preliminary relief on their own...

  4. Fabrication of bio-inspired nitinol alloy surface with tunable anisotropic wetting and high adhesive ability.

    Science.gov (United States)

    Tian, Yan L; Zhao, Yue C; Yang, Cheng J; Wang, Fu J; Liu, Xian P; Jing, Xiu B

    2018-10-01

    In this paper, micro/nano-scale structures were fabricated on nitinol alloy (NiTi) to realize tunable anisotropic wetting and high adhesive capability. Laser texturing and silanization process are utilized to change the morphological and chemical properties of substrates. It is noted that these treated substrates exhibit the joint characteristics of anisotropic wetting and high adhesive capability. In order to investigate the influences of laser-texturing and silanization processes on NiTi, these surfaces were evaluated using scanning electron microscope (SEM), a white light confocal microscope, X-ray photoelectron spectroscopy (XPS) and goniometer. The relationship between water volume and anisotropic wetting was also established. From the experimental testing, we can obtain the following conclusions: (1) the anisotropic wetting characterized by the difference between the water contact angles (WCAs) in the vertical and parallel directions ranges from 0° to 20.3°, which is far more than the value of natural rice leaves. (2) the water sliding angles (WSAs) kept stable at 180°, successfully mimicking the adhesive ability of rose petals. (3) the silanization process could strengthen the hydrophobicity but weaken anisotropic wetting. These bio-inspired NiTi surfaces have a tremendous potential applications such as microfluidic devices, bio-mimetic materials fabrication and lab on chip. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Influence of temporary cement contamination on the surface free energy and dentine bond strength of self-adhesive cements.

    Science.gov (United States)

    Takimoto, Masayuki; Ishii, Ryo; Iino, Masayoshi; Shimizu, Yusuke; Tsujimoto, Akimasa; Takamizawa, Toshiki; Ando, Susumu; Miyazaki, Masashi

    2012-02-01

    The surface free energy and dentine bond strength of self-adhesive cements were examined after the removal of temporary cements. The labial dentine surfaces of bovine mandibular incisors were wet ground with #600-grit SiC paper. Acrylic resin blocks were luted to the prepared dentine surfaces using HY Bond Temporary Cement Hard (HY), IP Temp Cement (IP), Fuji TEMP (FT) or Freegenol Temporary Cement (TC), and stored for 1 week. After removal of the temporary cements with an ultrasonic tip, the contact angle values of five specimens per test group were determined for the three test liquids, and the surface-energy parameters of the dentine surfaces were calculated. The dentine bond strengths of the self-adhesive cements were measured after removal of the temporary cements in a shear mode at a crosshead speed of 1.0mm/min. The data were subjected to one-way analysis of variance (ANOVA) followed by Tukey's HSD test. For all surfaces, the value of the estimated surface tension component γ(S)(d) (dispersion) was relatively constant at 41.7-43.3 mJm(-2). After removal of the temporary cements, the value of the γ(S)(h) (hydrogen-bonding) component decreased, particularly with FT and TC. The dentine bond strength of the self-adhesive cements was significantly higher for those without temporary cement contamination (8.2-10.6 MPa) than for those with temporary cement contamination (4.3-7.1 MPa). The γ(S) values decreased due to the decrease of γ(S)(h) values for the temporary cement-contaminated dentine. Contamination with temporary cements led to lower dentine bond strength. The presence of temporary cement interferes with the bonding performance of self-adhesive cements to dentine. Care should be taken in the methods of removal of temporary cement when using self-adhesive cements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Ambiguous diagnosis, futile treatments and temporary recovery ...

    African Journals Online (AJOL)

    Ambiguous diagnosis, futile treatments and temporary recovery: Meanings of medical treatment among HIV/AIDS family caregivers providing care without ARVs. ... to understand unstable treatment outcomes; and policy makers should strengthen home-based care by developing policies that integrate palliative care into HIV ...

  7. Responding to Multiple Institutional Logics in Inter-institutional Temporary Organizations

    DEFF Research Database (Denmark)

    Söderlund, Jonas; Pemsel, Sofia

    2016-01-01

    This paper draws on findings from a unique case study of a temporary organization that carried the responsibility for the planning and construction of a new super hospital in Stockholm, Sweden. Our empirical study explores how this temporary organization responded to requirements from different...... and sometimes conflicting institutional logics. The paper identifies four distinct response strategies that project actors relied upon to deal with the multiplicity of logics: total integration, partial decoupling, avoidance, and surfing. We discuss how these response strategies were used in the studied case...

  8. Temporary worker in the nuclear power industry: an equity analysis

    International Nuclear Information System (INIS)

    Melville, M.H.

    1981-01-01

    There are clear indications based both on the statistical data and on empirical evidence that the employment of large numbers of temporary workers has become a permanent and growing characteristic of the industry. It appears that the size of that work force has been seriously underestimated and that it receives a disproportionate share of the occupational radiation. In order to stay within the limits governing individual exposure in the workplace, the risk has been spread among a larger segment of the population. These facts raise important and ongoing issues of societal and employer responsibility. By the reckonings of this study, the total number of workers employed on a temporary basis by the nuclear power industry is eighteen times greater than those much more narrowly defined by the Nuclear Regulatory Commission (NRC) as transient workers: individuals hired and terminating employment with two or more employers in one quarter. It is estimated that the whole temporary work force numbered about 23,520 in 1976, over a third (35%) of the industry total, and absorbed 47.5% of the total occupational radiation dose. The problems, then, are not inconsiderable: they affect thousands of individuals, a significant segment of the nuclear power industry's work force, members of society who are subjected to a disproportionate burden of radiation risk. Among the conclusions is that it may be necessary to establish special standards, limitations, and records for temporary workers to ensure adequate health protection, follow-up, and care

  9. Closing a temporary ileostomy within two weeks

    DEFF Research Database (Denmark)

    Hindenburg, Tommy; Rosenberg, J.

    2010-01-01

    Temporary ileostomy is frequently constructed to relieve a rectal anastomosis and avoid peritonitis if the anastomosis is leaking. Ostomy is a burden for both the patient and society and early closure is therefore desirable to counteract increased morbidity. Several prospective studies and a single...

  10. Temporary vs. Permanent Sub-slab Ports: A Comparative ...

    Science.gov (United States)

    Vapor intrusion (VI) is the migration of subsurface vapors, including radon and volatile organic compounds (VOCs), from the subsurface to indoor air. The VI exposure pathway extends from the contaminant source, which can be impacted soil, non-aqueous phase liquid, or contaminated groundwater, to indoor air-exposure points. Therefore, contaminated matrices may include groundwater, soil, soil gas, and indoor air. VOC contaminants of concern typically include halogenated solvents such as trichloroethene, tetrachloroethene, and chloroform, as well as petroleum hydrocarbons, such as the aromatic VOCs benzene, toluene, and xylenes. Radon is a colorless radioactive gas that is released by radioactive decay of radionuclides in rock and soil that migrate into homes through VI in a similar fashion to VOCs. This project focused on the performance of permanent versus temporary sub-slab sampling ports for the determination of VI of halogenated VOCs and radon into an unoccupied house. VOC and radon concentrations measured simultaneously in soil gas using collocated temporary and permanent ports appeared to be independent of the type of port. The variability between collocated temporary and permanent ports was much less than the spatial variability between different locations within a single residential duplex. The agreement of the majority of VOC and radon concentrations, 0–36% relative percent difference, and 2–19% relative standard deviation respectively, of each sub-sl

  11. The Land Cover Dynamics and Conversion of Agricultural Land in Northwestern Bangladesh, 1973-2003.

    Science.gov (United States)

    Pervez, M.; Seelan, S. K.; Rundquist, B. C.

    2006-05-01

    The importance of land cover information describing the nature and extent of land resources and changes over time is increasing; this is especially true in Bangladesh, where land cover is changing rapidly. This paper presents research into the land cover dynamics of northwestern Bangladesh for the period 1973-2003 using Landsat satellite images in combination with field survey data collected in January and February 2005. Land cover maps were produced for eight different years during the study period with an average 73 percent overall classification accuracy. The classification results and post-classification change analysis showed that agriculture is the dominant land cover (occupying 74.5 percent of the study area) and is being reduced at a rate of about 3,000 ha per year. In addition, 6.7 percent of the agricultural land is vulnerable to temporary water logging annually. Despite this loss of agricultural land, irrigated agriculture increased substantially until 2000, but has since declined because of diminishing water availability and uncontrolled extraction of groundwater driven by population pressures and the extended need for food. A good agreement (r = 0.73) was found between increases in irrigated land and the depletion of the shallow groundwater table, a factor affecting widely practiced small-scale irrigation in northwestern Bangladesh. Results quantified the land cover change patterns and the stresses placed on natural resources; additionally, they demonstrated an accurate and economical means to map and analyze changes in land cover over time at a regional scale, which can assist decision makers in land and natural resources management decisions.

  12. Endoscopic management of unresectable malignant gastroduodenal obstruction with a nitinol uncovered metal stent: A prospective Japanese multicenter study

    Science.gov (United States)

    Sasaki, Reina; Sakai, Yuji; Tsuyuguchi, Toshio; Nishikawa, Takao; Fujimoto, Tatsuya; Mikami, Shigeru; Sugiyama, Harutoshi; Yokosuka, Osamu

    2016-01-01

    AIM: To determine the safety and efficacy of endoscopic duodenal stent placement in patients with malignant gastric outlet obstruction. METHODS: This prospective, observational, multicenter study included 39 consecutive patients with malignant gastric outlet obstruction. All patients underwent endoscopic placement of a nitinol, uncovered, self-expandable metal stent. The primary outcome was clinical success at 2 wk after stent placement that was defined as improvement in the Gastric Outlet Obstruction Scoring System score relative to the baseline. RESULTS: Technical success was achieved in all duodenal stent procedures. Procedure-related complications occurred in 4 patients (10.3%) in the form of mild pneumonitis. No other morbidities or mortalities were observed. The clinical success rate was 92.3%. The mean survival period after stent placement was 103 d. The mean period of stent patency was 149 d and the patency remained acceptable for the survival period. Stent dysfunction occurred in 3 patients (7.7%) on account of tumor growth. CONCLUSION: Endoscopic management using duodenal stents for patients with incurable malignant gastric outlet obstruction is safe and improved patients’ quality of life. PMID:27076769

  13. Eosinophilic cellulitis (Wells’ syndrome) caused by a temporary henna tattoo

    Science.gov (United States)

    Celegen, Mehmet; Karkıner, Canan Sule Unsal; Günay, Ilker; Diniz, Güllden; Can, Demet

    2014-01-01

    Eosinophilic cellulitis (Wells’ syndrome) is an uncommon condition of unknown etiology. Wells’ syndrome is usually seen in adulthood but very rare in childhood. Although pathogenesis of the disease is not very clear, it is a hypersensitivity reaction developing against a variety of exogenous and endogenous antigenic stimuli. Paraphenylenediamine is a strong allergen frequently used as a temporary henna tattoo, which makes the color darker. Here, a 9-year-old male patient with Wells’ syndrome is presented, which developed following a temporary henna tattoo and shown by the patch test sensitivity to paraphenylenediamine. PMID:25395929

  14. Magnesium alloys for temporary implant applications: stress corrosion cracking and biocompatible coating

    OpenAIRE

    Choudhary, Lokesh Kumar

    2017-01-01

    Magnesium (Mg) alloys have emerged as potential candidate materials for construction of biodegradable temporary implant devices particularly due to advantages of favourable mechanical properties, biodegradability and biocompatibility. However, the poor corrosion resistance of Mg alloys in the physiological environment presents a major challenge to their use as biodegradable temporary implants. Furthermore, complex interaction of mechanical loading and aggressive physiological environment may ...

  15. Assessment of the consequences in premature loss of the temporary lower molars.

    Science.gov (United States)

    Petcu, Ana; Bălan, Adriana; Gavrilă, Laura Maria Vasilca; Savin, Carmen

    2014-01-01

    The consequences of premature loss of temporary teeth are complex, both of functional and morphological order and the clinical presentation depends on multiple factors: the temporary tooth loss rate as compared with permanent tooth eruption sequence and the number and topography of teeth extracted, so the clinical form of edentulous, which can be frontal or lateral, symmetric or asymmetric, isolated or continuous.

  16. 78 FR 46339 - Medicare, Medicaid, and Children's Health Insurance Programs: Announcement of Temporary Moratoria...

    Science.gov (United States)

    2013-07-31

    ...] Medicare, Medicaid, and Children's Health Insurance Programs: Announcement of Temporary Moratoria on... combat fraud, waste, and abuse in Medicare, Medicaid, and the Children's Health Insurance Program (CHIP... Health Insurance Programs; Additional Screening Requirements, Application Fees, Temporary Enrollment...

  17. Transcending Organization in Temporary Systems

    DEFF Research Database (Denmark)

    Stjerne, Iben Sandal

    in temporary systems that lack stability and formal order. It advances our understanding of transcending organization in creative industries by adopting a practice based perspective. Empirically, the dissertation presents an in-depth study of the Danish film industry, which is an extreme case of a project...... film workers with different functional roles and six months of ethnographic study of film projects in the Danish film industry, in particular delving into the film project Antboy and its sequels....

  18. A diatom functional-based approach to assess changing environmental conditions in temporary depressional wetlands

    CSIR Research Space (South Africa)

    Riato, L

    2017-07-01

    Full Text Available is limited although important for the development of temporary wetland biological assessments. We assessed how diatom life-form and ecological guilds responded to a seasonal hydrological and hydrochemical gradient in three least human-disturbed, temporary...

  19. Development and evaluation of temporary placement and conveyance operation simulation system using augmented reality

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Weida; Aoyama, Shuhei; Ishii, Hirotake; Shimoda, Hiroshi [Graduate School of Energy Science, Kyoto University, Kyoto (Japan); Sang, Tran T.; Inge, Solhang Lars [AR Lab, Halden (Norway); Lygren, Toppe Aleksander; Terje, Johnsen [Institute for Energy Technolog, Halden (Norway); Izumi, Masanori [Fugen Decommissioning Engineering Center, Japan Atomic Energy Agency, Fukui (Japan)

    2012-06-15

    When decommissioning a nuclear power plant, it is difficult to make an appropriate plan to ensure sufficient space for temporary placement and conveyance operations of dismantling targets. This paper describes a system to support temporary placement and conveyance operations using augmented reality (AR). The system employs a laser range scanner to measure the three-dimensional (3D) information of the environment and a dismantling target to produce 3D surface polygon models. Then, the operator simulates temporary placement and conveyance operations using the system by manipulating the obtained 3D model of the dismantling target in the work field. Referring to the obtained 3D model of the environment, a possible collision between the dismantling target and the environment is detectable. Using AR, the collision position is presented intuitively. After field workers evaluated this system, the authors concluded that the system is feasible and acceptable to verify whether spaces for passage and temporary storage are sufficient for temporary placement and conveyance operations. For practical use in the future, some new functions must be added to improve the system. For example, it must be possible for multiple workers to use the system simultaneously by sharing the view of dismantling work.

  20. Development and evaluation of temporary placement and conveyance operation simulation system using augmented reality

    International Nuclear Information System (INIS)

    Yan, Weida; Aoyama, Shuhei; Ishii, Hirotake; Shimoda, Hiroshi; Sang, Tran T.; Inge, Solhang Lars; Lygren, Toppe Aleksander; Terje, Johnsen; Izumi, Masanori

    2012-01-01

    When decommissioning a nuclear power plant, it is difficult to make an appropriate plan to ensure sufficient space for temporary placement and conveyance operations of dismantling targets. This paper describes a system to support temporary placement and conveyance operations using augmented reality (AR). The system employs a laser range scanner to measure the three-dimensional (3D) information of the environment and a dismantling target to produce 3D surface polygon models. Then, the operator simulates temporary placement and conveyance operations using the system by manipulating the obtained 3D model of the dismantling target in the work field. Referring to the obtained 3D model of the environment, a possible collision between the dismantling target and the environment is detectable. Using AR, the collision position is presented intuitively. After field workers evaluated this system, the authors concluded that the system is feasible and acceptable to verify whether spaces for passage and temporary storage are sufficient for temporary placement and conveyance operations. For practical use in the future, some new functions must be added to improve the system. For example, it must be possible for multiple workers to use the system simultaneously by sharing the view of dismantling work.

  1. A randomized comparison of a novel nitinol-frame low-dose-copper intrauterine contraceptive and a copper T380S intrauterine contraceptive.

    Science.gov (United States)

    Reeves, Matthew F; Katz, Bob H; Canela, Juan M; Hathaway, Mark J; Tal, Michael G

    2017-06-01

    We sought to compare VeraCept (VC175), a novel nitinol intrauterine contraceptive (IUC) with 175 square-mm of copper surface area, to a copper T380S IUC. We enrolled parous women into a randomized subject-blinded comparison of VC175 and a copper T380S in a 2:1 fashion at a single clinic. The primary outcomes were total adverse events and continuation at 12 months. We also examined pain on insertion, ease of placement, expulsion, tolerability and pregnancy. Subjective ratings were on a 5-point Likert scale (0, no pain to 5, worst pain). We followed subjects through 24-month follow-up. We enrolled 300 women with 199 randomized to VC175 and 101 to the T380S. Insertion was successful in 198 subjects for VC175 and 100 for the T380S. Mean age was 25 years (range 18, 41), and median parity was 2 (range 1, 8), with 39% having only had Cesarean deliveries. No subjects developed clinical infection or reported serious adverse events. In the VC175 and T380S groups, mean pain at insertion was 1.4 and 2.4, respectively (p<.01). At the 12-month primary endpoint for VC175 and T380S, respectively, continuation was 84% and 68% (p<.002) with expulsions in 5.0% and 12.0% (p<.05) and removal for pain/bleeding in 3.5% and 17.0% (p<.01). At the 24-month visit for VC175 and T380S, respectively, continuation was 77% and 62% (p<.02 by log-rank). One ectopic pregnancy was identified at the 12-month follow-up in a VC175 user. No other pregnancies were diagnosed. With 297.3 and 132.4 woman-years, pregnancy rates were 0.3 and 0.0 per 100 woman-years for VC175 and T380S, respectively. VC175 resulted in less pain at insertion, fewer expulsions and higher total continuation than the T380S, with similar contraceptive efficacy. VC175 is a promising new intrauterine copper contraceptive on a nitinol frame that warrants further clinical trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Temporary restorative treatment in children and adolescents with amelogenesis imperfecta: Scoping review.

    Directory of Open Access Journals (Sweden)

    Cristhian Cisneros

    2017-12-01

    Full Text Available Background: Amelogenesis imperfecta (AI is a group of disorders that affect the enamel of the teeth, either in quality or quantity. This alteration causes sensitivity and is associated with factors that could affect the strength of the adhesive bond of the restorative material. Aim: To review the literature regarding the most used temporary restorative treatment in children and adolescents with AI. Methods: This scoping review aimed to include case reports, literature reviews and original studies that evaluated restorative materials for the teeth of children and adolescents with AI. Editorials, meeting abstracts and letters to the editor were excluded. The following electronic databases were used: Medline (Ovid, PubMed, Ebsco, Scopus (Elsevier and Web of Science (Thomson Reuters. Manual searches in the reference lists of the included articles were also carried out. Finally, a search in Google Scholar restricted to the first 100 hits was performed. Duplicates were eliminated upon identification. The search covered a period between the years of 2011 and 2016. PRISMA guidelines were used for reporting the review. The evidence ranking was carried out by means of the Oxford criteria. Results: Six articles met the eligibility criteria and were included in this scoping review. Three articles were case reports, one was a review and two were original studies. For the treatment of AI, direct or indirect composite resins were the most commonly used material of choice in the retrieved studies because they demonstrate greater longevity, aesthetics and function compared to the other materials used. Conclusions: Among children and adolescents with AI, the temporary restorative treatment that demonstrated better long-term results in permanent teeth was the direct and indirect composite resins. However, high quality studies should be conducted to confirm the results presented herein.

  3. 17 CFR 274.404 - Form TH-Notification of reliance on temporary hardship exemption.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Form TH-Notification of... Forms for Electronic Filing § 274.404 Form TH—Notification of reliance on temporary hardship exemption. Form TH shall be filed by any electronic filer who submits to the Commission, pursuant to a temporary...

  4. 78 FR 20123 - Extension of the Designation of Honduras for Temporary Protected Status

    Science.gov (United States)

    2013-04-03

    ... Docket No. USCIS-2012-0016] RIN 1615-ZB18 Extension of the Designation of Honduras for Temporary... the designation of Honduras for Temporary Protected Status (TPS) for 18 months from July 6, 2013... Honduras that prompted the TPS designation continue to be met. There continues to be a substantial, but...

  5. Considerations on National and Union Regulations of Work through a Temporary Employment Agent

    Directory of Open Access Journals (Sweden)

    Carmen Constantina Nenu

    2013-05-01

    Full Text Available The necessity to adapt the organizational structure of economic operators to the competitive European market requirements has imposed measures that have also influenced labor relations. The permanent and full-time employment relationship has been largely replaced by other types of more flexible labor relationships: temporary employment, part-time work. working from home and temporary assignment through an employment agency. All these types of work relationships are characterized by a decrease of guarantees for the employee and by a reduction of trade union power. Thus, they are considered atypical work relationships. The need to make the flexibility of labor relationships compatible with the protection of employees” rights has been a challenge that must be faced by social policies and also by labor law. In this context, the use of a temporary employment agent has been a tool for flexible working relationships both with the economic operators and within the labor market as a whole. The importane and role of this type of working relationship has, therefore, acquired significant legal, economic and social dimensions, which this study intends to analyze. In a European economy hit by the jobs crisis, reliance on work through a temporary employment agent can be a way to reduce unemployment. This happens only if the temporary workers benefit from legal protection and equal treatment as permanent employees.

  6. Temporary Fecal Diversion in the Management of Colorectal and Perianal Crohn’s Disease

    Directory of Open Access Journals (Sweden)

    Rudolf Mennigen

    2015-01-01

    Full Text Available Aim. To evaluate the results of temporary fecal diversion in colorectal and perianal Crohn’s disease. Method. We retrospectively identified 29 consecutive patients (14 females, 15 males; median age: 30.0 years, range: 18–76 undergoing temporary fecal diversion for colorectal (n=14, ileal (n=4, and/or perianal Crohn’s disease (n=22. Follow-up was in median 33.0 (3–103 months. Response to fecal diversion, rate of stoma reversal, and relapse rate after stoma reversal were recorded. Results. The response to temporary fecal diversion was complete remission in 4/29 (13.8%, partial remission in 12/29 (41.4%, no change in 7/29 (24.1%, and progress in 6/29 (20.7%. Stoma reversal was performed in 19 out of 25 patients (76% available for follow-up. Of these, the majority (15/19, 78.9% needed further surgical therapies for a relapse of the same pathology previously leading to temporary fecal diversion, including colorectal resections (10/19, 52.6% and creation of a definitive stoma (7/19, 36.8%. At the end of follow-up, only 4/25 patients (16% had a stable course without the need for further definitive surgery. Conclusion. Temporary fecal diversion can induce remission in otherwise refractory colorectal or perianal Crohn’s disease, but the chance of enduring remission after stoma reversal is low.

  7. Combined hysteroscopy-laparoscopy approach for excision of pelvic nitinol fragment from Essure contraceptive device: Role of intraoperative fluoroscopy for uterine conservation.

    Science.gov (United States)

    Sills, E Scott; Palermo, Gianpiero D

    2016-07-01

    We describe the successful removal of a pelvic contraceptive coil in a symptomatic 46-year-old patient who had Essure devices for four years, using a combined hysteroscopy-laparoscopy-fluoroscopy approach. Following normal hysteroscopy, at laparoscopy the right Essure implant was disrupted and its outer nitinol coil had perforated the fallopian tube. However, the inner rod (containing polyethylene terephthalate) had migrated to an extrapelvic location, near the proximal colon. In contrast, the left implant was situated within the corresponding tube. Intraoperative fluoroscopy was used to confirm complete removal of the device, which was further verified by postoperative computed tomography. The patient's condition improved after surgery and she continues to do well. This is the first report to describe this technique in managing Essure complications remote from time of insertion. Our case highlights the value and limitations of preoperative and intraoperative imaging to map Essure fragment location before surgery.

  8. Associations between temporary employment and occupational injury: what are the mechanisms?

    Science.gov (United States)

    Benavides, F G; Benach, J; Muntaner, C; Delclos, G L; Catot, N; Amable, M

    2006-06-01

    To determine whether observed higher risks of occupational injury among temporary workers are due to exposure to hazardous working conditions and/or to lack of job experience level. Data systematically recorded for 2000 and 2001 by the Spanish Ministry of Labour and Social Affairs on fatal and non-fatal traumatic occupational injuries were examined by type of employment and type of accident, while adjusting for gender, age, occupation, and length of employment in the company. In the study period there were 1500 fatal and 1 806 532 non-fatal traumatic occupational injuries that occurred at the workplace. Incidence rates and rate ratios (RR) were estimated using Poisson regression models. Temporary workers showed a rate ratio of 2.94 for non-fatal occupational injuries (95% CI 2.40 to 3.61) and 2.54 for fatal occupational injuries (95% CI 1.88 to 3.42). When these associations were adjusted by gender, age, occupation, and especially length of employment, they loose statistic significance: 1.05 (95% CI 0.97 to 1.12) for non-fatal and 1.07 (95% CI 0.91 to 1.26) for fatal. Lower job experience and knowledge of workplace hazards, measured by length of employment, is a possible mechanism to explain the consistent association between temporary workers and occupational injury. The role of working conditions associated with temporary jobs should be assessed more specifically.

  9. 26 CFR 1.468A-1T - Nuclear decommissioning costs; general rules (temporary).

    Science.gov (United States)

    2010-04-01

    ... accrual method of accounting that do not elect the application of section 468A are not allowed a deduction... (temporary). 1.468A-1T Section 1.468A-1T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...-1T Nuclear decommissioning costs; general rules (temporary). (a) Introduction. Section 468A provides...

  10. Mapping the temporary and perennial character of whole river networks

    Science.gov (United States)

    González-Ferreras, A. M.; Barquín, J.

    2017-08-01

    Knowledge of the spatial distribution of temporary and perennial river channels in a whole catchment is important for effective integrated basin management and river biodiversity conservation. However, this information is usually not available or is incomplete. In this study, we present a statistically based methodology to classify river segments from a whole river network (Deva-Cares catchment, Northern Spain) as temporary or perennial. This method is based on an a priori classification of a subset of river segments as temporary or perennial, using field surveys and aerial images, and then running Random Forest models to predict classification membership for the rest of the river network. The independent variables and the river network were derived following a computer-based geospatial simulation of riverine landscapes. The model results show high values of overall accuracy, sensitivity, and specificity for the evaluation of the fitted model to the training and testing data set (≥0.9). The most important independent variables were catchment area, area occupied by broadleaf forest, minimum monthly precipitation in August, and average catchment elevation. The final map shows 7525 temporary river segments (1012.5 km) and 3731 perennial river segments (662.5 km). A subsequent validation of the mapping results using River Habitat Survey data and expert knowledge supported the validity of the proposed maps. We conclude that the proposed methodology is a valid method for mapping the limits of flow permanence that could substantially increase our understanding of the spatial links between terrestrial and aquatic interfaces, improving the research, management, and conservation of river biodiversity and functioning.

  11. 77 FR 12723 - Labor Certification Process for the Temporary Employment of Aliens in Agriculture in the United...

    Science.gov (United States)

    2012-03-02

    ... the Temporary Employment of Aliens in Agriculture in the United States; Announcement of Non- Material... reasons in great detail in the preamble of the ``Temporary Agricultural Employment of H-2A Aliens in the... set the AEWR. See ``Temporary Agricultural Employment of H-2A Aliens in the United States; Modernizing...

  12. Corrosion resistance improvement of nitinol by anodisation in the presence of molybdate ions

    Energy Technology Data Exchange (ETDEWEB)

    Saugo, M. [Instituto de Ingeniería Electroquímica y Corrosión (INIEC), Departamento de Ingeniería Química, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahía Blanca (Argentina); Flamini, D.O., E-mail: dflamini@uns.edu.ar [Instituto de Ingeniería Electroquímica y Corrosión (INIEC), Departamento de Ingeniería Química, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahía Blanca (Argentina); Zampieri, G. [Centro Atómico Bariloche, Comisión Nacional de Energía Atómica, Av. Bustillo 9500, 8400 San Carlos de Bariloche (Argentina); Instituto Balseiro, Universidad Nacional de Cuyo, Av. Bustillo 9500, 8400 San Carlos de Bariloche (Argentina); Saidman, S.B. [Instituto de Ingeniería Electroquímica y Corrosión (INIEC), Departamento de Ingeniería Química, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahía Blanca (Argentina)

    2017-04-01

    The corrosion behaviour of Nitinol (NiTi) alloy was studied in Ringer solution. In order to improve its corrosion resistance, protective films were formed on the NiTi surface by means of anodisation under potentiostatic or galvanostatic control in the presence of the corrosion inhibitor molybdate in alkaline and acidic solutions. The anodisation process reduces considerably the Ni content and increases the Ti content in the oxide film, indicating that the Ti/Ni stoichiometry in the outermost surface is much higher than in pure NiTi. The titanium enrichment on the outermost surface as TiO{sub 2} enhanced its anticorrosion performance, as was suggested by the decrease in the amount of Ni and Ti released in Ringer solution under open circuit potential (OCP) condition and under potentials where the bare substrate suffers pitting attack. The best anodised film in terms of corrosion protection was obtained under potentiostatic condition in alkaline solution. The presence of oxidised molybdenum species in the oxide potentiostatically grown in alkaline solution, generates a corrosion protective film with a smoother and denser surface than other oxides formed in acidic solutions, without any defects like micro-cracks or pores. - Highlights: • NiTi alloy was anodised applying a low voltage in the presence of a MoO{sub 4}{sup −2} solution. • The formed oxides provided good corrosion protection to the substrate. • The presence of Mo in the oxide film was confirmed by different techniques. • The increase of the Ti/Ni ratio in the oxidised sample was key to protection.

  13. Inference about density and temporary emigration in unmarked populations

    Science.gov (United States)

    Chandler, Richard B.; Royle, J. Andrew; King, David I.

    2011-01-01

    Few species are distributed uniformly in space, and populations of mobile organisms are rarely closed with respect to movement, yet many models of density rely upon these assumptions. We present a hierarchical model allowing inference about the density of unmarked populations subject to temporary emigration and imperfect detection. The model can be fit to data collected using a variety of standard survey methods such as repeated point counts in which removal sampling, double-observer sampling, or distance sampling is used during each count. Simulation studies demonstrated that parameter estimators are unbiased when temporary emigration is either "completely random" or is determined by the size and location of home ranges relative to survey points. We also applied the model to repeated removal sampling data collected on Chestnut-sided Warblers (Dendroica pensylvancia) in the White Mountain National Forest, USA. The density estimate from our model, 1.09 birds/ha, was similar to an estimate of 1.11 birds/ha produced by an intensive spot-mapping effort. Our model is also applicable when processes other than temporary emigration affect the probability of being available for detection, such as in studies using cue counts. Functions to implement the model have been added to the R package unmarked.

  14. 76 FR 43376 - Order Granting Temporary Exemptions From Certain Government Securities Act Provisions and...

    Science.gov (United States)

    2011-07-20

    .../gsareg.htm . As noted in its request, on July 16, 2011, ICE Trust reorganized its corporate structure... DEPARTMENT OF THE TREASURY Order Granting Temporary Exemptions From Certain Government Securities... temporary exemptions from certain Government Securities Act of 1986 provisions and regulations regarding...

  15. Incidental Detection of Temporary Focal FDG Retention in the Spleen

    Energy Technology Data Exchange (ETDEWEB)

    Park, Youn Joon; Lee, Jai Hyuen; Jee, Keum Nahn; Namgung, Hwan [Dankook Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    F 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) is a valuable tool in discriminating malignancy from benign lesion. But because various false positive results reduce the diagnostic specificity, nuclear medicine physicians should be familiar with possible false positive cases. Although many cases of high FDG uptake mimicking malignancy have been reported, temporary intense focal FDG uptake of normal spleen has not been reported previously. We report herein a phenomenon of temporary intense focal FDG uptake of normal spleen without evidence of metastasis in a 46 year old woman with a history of anal cancer.

  16. The Diaspora and Temporary Migrant Workers: Basic Concepts

    Directory of Open Access Journals (Sweden)

    Marija Krstić

    2016-02-01

    Full Text Available The paper looks at the phenomenon of migrant workers who emigrated to Western European countries after World War II. The labor demands created by the economic reconstruction of these countries, most notably Great Britain, West Germany, France, Switzerland, the Benelux countries, Sweden and Austria, coupled with low birth rates and high death rates, made it necessary for them to hire immigrant workers. On the other hand, poor economic conditions, few employment opportunities and a yearning for a higher standard of living drove workers from Italy, Spain, Portugal, Turkey, Yugoslavia, Greece, Ireland, Finland and North Africa to seek work abroad. These temporary migrant workers represent a link between their countries of origin and their host countries, and, as a group of people maintaining links with their native countries, they can also be considered their countries’ diaspora. However, considering the temporary nature of their residence abroad, it is questionable whether they actually are a diaspora. It is for this reason that the paper juxtaposes the phenomena of the diaspora and temporary migrant workers in order to analyze the question of whether, when and how these workers become a diaspora. In particular, it focuses on migrant workers from Yugoslavia, usually referred to as “gastarbajteri” (gastarbeiter, who in the 1960s and 1970s migrated mostly to West Germany, Austria, Australia, France and Switzerland, and on their political treatment by the Yugoslav state.

  17. Physical Exposures, Work Tasks, and OSHA-10 Training Among Temporary and Payroll Construction Workers.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Santiago, Katerina M; Stillman, Jordan; Moore, Kevin J; Sierra, Danielle A; Chalmers, Juanita; Baniak, Melissa; Jordan, Melissa M

    2018-04-01

    We characterize and compare the self-reported physical exposures, work tasks, and OSHA-10 training in a non-probabilistic sample of temporary and payroll construction workers. In June 2016, a total of 250 payroll and temporary general laborers employed at Florida construction sites completed a survey at the job site as part of the falls reported among minority employees (FRAME) study. Workers employed through temp agencies (57.1%) were significantly more likely to report moving or lifting materials more than 100 pounds than payroll workers (38.5%; P < 0.01). Temporary construction workers with 10-hour OSHA training (22.2%) spent significantly less time with intense hand use/awkward hand posture than temporary workers without 10-hour OSHA training (46.9%; P = 0.048). Temp construction workers with OSHA 10-hour training reported less hazardous physical postures than workers without the same training.

  18. 20 CFR 416.1149 - What is a temporary absence from your living arrangement.

    Science.gov (United States)

    2010-04-01

    ... SECURITY INCOME FOR THE AGED, BLIND, AND DISABLED Income Temporary Absence § 416.1149 What is a temporary... under age 22, you are temporarily absent while you are away at school, regardless of how long you are... provided in school regulations). (ii) However, if you are a child under age 18, and your permanent living...

  19. Coronal microleakage with five different temporary restorative materials following walking bleach technique: An ex-vivo study

    Directory of Open Access Journals (Sweden)

    G. P. V Srikumar

    2012-01-01

    Full Text Available Context: Walking bleach technique uses 30% hydrogen peroxide and sodium perborate, and this paste mixture causes loosening of the coronal temporary restorative materials and thus decreasing its clinical effectiveness and causing irritation to the patients oral tissues. In the present study, sealing ability of hygroscopic coronal temporary restorative materials were compared with the other commonly used temporary restorative materials. Aim: To evaluate the effects of walking bleach material on the marginal sealing ability and coronal microleakage of the hydrophilic temporary restorative materials with that of the other commonly used temporary restorative materials in endodontic practice. Materials and Methods: Seventy-five extracted human maxillary central incisor teeth were prepared chemo-mechanically and obturated with gutta-percha in lateral condensation technique. Surface of each tooth was double coated with cyanoacrylate glue. All the teeth were randomly divided in to five groups. Out of 15 teeth in each group, 10 teeth served as experimental specimens, in which bleaching agent was placed in the pulp chamber and 5 teeth served as control, in which no bleaching agent was placed. The access cavities were restored with temporary restorative materials being tested per each group respectively. The specimens were then immersed in 1% India ink dye and subjected to thermo cycling for 7 days. All the teeth were longitudinally sectioned and observed with stereomicroscope and were graded according to the depth of linear dye penetration. Statistical Analysis Used: Mann-Whitney U test and Kruskal-Wallis test. Results: Hydrophilic temporary restorative materials Cavit G and Coltosol F have shown minimal coronal dye leakage with better sealing ability when exposed to walking bleach paste mixture in the dye penetration tests compared to other commonly used temporary restorative materials. Conclusion: Marginal sealing ability of Cavit G and Coltosol F were

  20. Reciprocity of temporary and permanent workers: an exploratory study in an industrial company.

    Science.gov (United States)

    Lopes, Silvia; Chambel, Maria José

    2012-11-01

    The increasing use of temporary work prompts the need to understand to what degree workers with this type of contract differ from permanent workers as to the relationship they establish with the organization they work for. This study used a sample of temporary workers (N = 78) and permanent workers (N = 196) within the same company of electronics in Portugal. The results show that, regardless of the type of contract, the perception of human resource practices was related to the perception of psychological contract fulfillment by the company. Additionally and according to the norm of reciprocity, we verified that when workers thought the company was fulfilling its obligations they responded favorably showing more affective commitment towards the company. However, we found differences between these two groups of workers: for the permanent performance appraisal, training and rewards were human resources practices that were significantly related to psychological contract fulfillment, while for the temporary ones there weren't any specific practices that had a significant relationship with that variable. The practical implications of these findings for the management of temporary workers are discussed.

  1. Design, construction and monitoring of temporary storage facilities for removed contaminants

    International Nuclear Information System (INIS)

    Saegusa, Hiromitsu; Funaki, Hironori; Kurikami, Hiroshi; Sakamoto, Yoshiaki; Tokizawa, Takayuki

    2013-01-01

    Since the Fukushima Daiichi nuclear power plant accident caused by the Tohoku Region Pacific Coast Earthquake on March 11, 2011, decontamination work has been conducted in the surrounding environment within the Fukushima prefecture. Removed contaminants including soil, grass and trees are to be stored safely at temporary storage facilities for up to three years, after which they will be transferred to a planned interim storage facility. The decontamination pilot project was carried out in both the restricted and planned evacuation areas in order to assess decontamination methods and demonstrate measures for radiation protection of workers. Fourteen temporary storage facilities of different technical specifications were designed and constructed under various topographic conditions and land use. In order to support the design, construction and monitoring of temporary storage facilities for removed contaminants during the full-scale decontamination within the prefecture of Fukushima, technical know-how obtained during the decontamination pilot project has been identified and summarized in this paper. (author)

  2. The mid-term efficacy and safety of a permanent nitinol IVC filter (TrapEase)

    International Nuclear Information System (INIS)

    Liu, Wei Chiang; Do, Young Soo; Choo, Sung Wook; Kim, Dong Ik; Kim, Young Wook; Kim, Duk Kyung; Shin, Sung Wook; Park, Kwang Bo; Jeon, Yong Hwan; Choo, In Wook

    2005-01-01

    1) To evaluate the mid-term efficacy and safety of a permanent nitinol inferior vena cava (IVC) filter; 2) to evaluate filter effectiveness, filter stability and caval occlusion. A prospective evaluation of the TrapEase IVC filter was performed on 42 patients (eight men, 34 women) ranging in age from 22 to 78 years (mean age 66 years). All patients were ill with a high risk of pulmonary embolism (PE). Indications for filter placement were: 1) deep vein thrombosis with recurrent thromboembolism; 2) and/or free-floating thrombus with contraindication to anticoagulation; and 3) complications in achieving adequate anticoagulation. Follow-up evaluations (mean: 15.4 months, range: 2 to 28 months) were performed at 6- and 12-month intervals after the procedure and included clinical histories, chart reviews, plain film, Doppler ultrasounds, and contrasted abdominal CT scans. In follow-up evaluations, the data analysis revealed no cases of symptomatic PE. There were no cases of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study, there was one case of filter thrombosis; early symptomatic thrombosis that was successfully treated in the hospital. Of the 42 subjects, eight dead. These deaths were not related to the filter device or the implantation procedure, but to the underlying disease. This study demonstrates that the TrapEase permanent IVC filter is a safe and an effective device with low complication rates and is best used in patients with thromboembolic disease with a high risk of PE

  3. Personal use of hair dyes and temporary black tattoos in Copenhagen hairdressers

    DEFF Research Database (Denmark)

    Hansen, Henriette S; Johansen, Jeanne D; Thyssen, Jacob P

    2010-01-01

    Hairdressers are occupationally and personally exposed to hair dye substances and adverse reactions from the skin are well known. Currently, little is known about personal exposure to hair dye ingredients and temporary black tattoos.......Hairdressers are occupationally and personally exposed to hair dye substances and adverse reactions from the skin are well known. Currently, little is known about personal exposure to hair dye ingredients and temporary black tattoos....

  4. 30 CFR 816.131 - Cessation of operations: Temporary.

    Science.gov (United States)

    2010-07-01

    ..., revegetation, environmental monitoring, and water treatment activities that will continue during the temporary... Section 816.131 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PERMANENT PROGRAM PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-SURFACE MINING...

  5. Temporary contracts : Effect on job satisfaction and personal lives of recent PhD graduates

    NARCIS (Netherlands)

    Waaijer, C.J.F.; Belder, R.; Sonneveld, H.; Van, Bochove C.A.; Van, der Weijden I.C.M.

    2017-01-01

    In this study, we assess the effects of temporary employment on job satisfaction and the personal lives of recent PhD graduates. Temporary employment is becoming increasingly prevalent in many sectors, but has been relatively common in academia, especially for early career scientists. Labor market

  6. 5 CFR 890.1105 - Initial election of temporary continuation of coverage; application time limitations and...

    Science.gov (United States)

    2010-01-01

    ... (ii) The date of the divorce or annulment. (e) If an individual who is eligible for temporary... determines that an eligible individual was unable, for cause beyond his or her control, to elect temporary...

  7. Coronal microleakage of four temporary restorative materials in Class II-type endodontic access preparations

    Directory of Open Access Journals (Sweden)

    Sang-Mi Yun

    2012-02-01

    Full Text Available Objectives The purpose of this study was to evaluate the microleakage of 4 temporary materials in teeth with Class II-type endodontic access preparations by using a glucose penetration model. Materials and Methods Glucose reaction test was performed to rule out the presence of any reaction between glucose and temporary material. Class II-type endodontic access preparations were made in extracted human premolars with a single root (n = 10. Each experimental group was restored with Caviton (GC, Spacer (Vericom, IRM (Dentsply-Caulk, or Fuji II(GC. Microleakage of four materials used as temporary restorative materials was evaluated by using a glucose penetration model. Data were analyzed by the one-way analysis of variance followed by a multiple-comparison Tukey test. The interface between materials and tooth were examined under a scanning electron microscope (SEM. Results There was no significant reaction between glucose and temporary materials used in this study. Microleakage was significantly lower for Caviton and Spacer than for Fuji II and IRM. SEM observation showed more intimate adaptation of tooth-restoration interfaces in Caviton and Spacer than in IRM and Fuji II. Conclusions Compared to IRM and Fuji II, Caviton and Spacer can be considered better temporary sealing materials in Class II-type endodontic access cavities.

  8. 5 CFR 351.608 - Permissive temporary exceptions.

    Science.gov (United States)

    2010-01-01

    .... This does not preclude the employee from receiving or accepting a job offer in the same competitive... date beyond the effective date of the reduction in force when the temporary retention of a lower... retention will end; and (2) List opposite the employee's name on the retention register the reasons for the...

  9. 75 FR 63184 - Temporary Duty (TDY) Travel Allowances

    Science.gov (United States)

    2010-10-14

    ... GENERAL SERVICES ADMINISTRATION [Docket 2010-0009, Sequence 4] Temporary Duty (TDY) Travel Allowances AGENCY: Office of Governmentwide Policy, General Services Administration (GSA). ACTION: Notice of... agency travel programs, save money on travel costs, better protect the environment, and conserve natural...

  10. MACROECONOMIC KALECKI’S MODEL IN VIEW OF AN INVESTMENT TEMPORARY LAG

    Directory of Open Access Journals (Sweden)

    Eduard A. Gevorkyan

    2015-01-01

    Full Text Available The dependence of the gross domestic product on time ( Y ( t in macroeconomic Kalecki’s model in view of an investment temporary lag in the case of periodic dependence of the consumption function on time is investigated. As a result of solutions of linear ordinary differential equation and differential equation with lagging argument an analytical expressions for the Y ( t is received. Some aspects of influence of a temporary lag on character of variation of the function Y ( t are shown.

  11. A study on setting of the fatigue limit of temporary dental implants.

    Science.gov (United States)

    Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W

    2017-07-01

    A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.

  12. The Impact of Education and Occupation on Temporary and Permanent Work Incapacity

    DEFF Research Database (Denmark)

    Datta Gupta, Nabanita; Lau, Daniel; Pozzoli, Dario

    and occupation by estimating a quasi-maximum-likelihood discrete factor model. Data on sickness absence and disability spells for the population of older workers come from the Danish administrative registers for 1998-2002. We generally find an independent role of both education and occupation on temporary work......This paper investigates whether education and working in a physically demand- ing job causally impact temporary work incapacity, i.e. sickness absence, and permanent work incapacity, i.e. the inflow to disability via sickness absence. Our contribution is to allow endogeneity of both education...... incapacity only. Having at least primary education reduces women's (men's) probability of temporary work incapacity by 16% (38%) while working in a physically demanding job increases it by 37% (26%). On the other hand, conditional on sickness absence, the effects of education and occupation on permanent work...

  13. Communities of belonging in the temporariness of the Danish Asylum System: Shalini’s anchoring points

    DEFF Research Database (Denmark)

    Verdasco, Andrea

    2018-01-01

    Refugees often find themselves in a protracted situation of temporariness, as applications for asylum are processed, deportations negotiated and possible extensions of temporary protection status considered within the context of increasingly restrictive governmental policies across Europe. Through...

  14. Water and sediment transport modeling of a large temporary river basin in Greece.

    Science.gov (United States)

    Gamvroudis, C; Nikolaidis, N P; Tzoraki, O; Papadoulakis, V; Karalemas, N

    2015-03-01

    The objective of this research was to study the spatial distribution of runoff and sediment transport in a large Mediterranean watershed (Evrotas River Basin) consisting of temporary flow tributaries and high mountain areas and springs by focusing on the collection and use of a variety of data to constrain the model parameters and characterize hydrologic and geophysical processes at various scales. Both monthly and daily discharge data (2004-2011) and monthly sediment concentration data (2010-2011) from an extended monitoring network of 8 sites were used to calibrate and validate the Soil and Water Assessment Tool (SWAT) model. In addition flow desiccation maps showing wet and dry aquatic states obtained during a dry year were used to calibrate the simulation of low flows. Annual measurements of sediment accumulation in two reaches were used to further calibrate the sediment simulation. Model simulation of hydrology and sediment transport was in good agreement with field observations as indicated by a variety of statistical measures used to evaluate the goodness of fit. A water balance was constructed using a 12 year long (2000-2011) simulation. The average precipitation of the basin for this period was estimated to be 903 mm yr(-1). The actual evapotranspiration was 46.9% (424 mm yr(-1)), and the total water yield was 13.4% (121 mm yr(-1)). The remaining 33.4% (302 mm yr(-1)) was the amount of water that was lost through the deep groundwater of Taygetos and Parnonas Mountains to areas outside the watershed and for drinking water demands (6.3%). The results suggest that the catchment has on average significant water surplus to cover drinking water and irrigation demands. However, the situation is different during the dry years, where the majority of the reaches (85% of the river network are perennial and temporary) completely dry up as a result of the limited rainfall and the substantial water abstraction for irrigation purposes. There is a large variability in the

  15. 20 CFR 655.21 - Supporting evidence for temporary need.

    Science.gov (United States)

    2010-04-01

    ... Attestations for Temporary Employment in Occupations Other Than Agriculture or Registered Nursing in the United... containing the following: (1) A description of the employer's business history and activities (i.e., primary...

  16. Temporary vesicostomy-assisted urethroplasty for recurrent obliterated posterior urethral stricture.

    Science.gov (United States)

    Liu, Jui-Ming; Wang, Ta-Min; Chiang, Yang-Jen; Chen, Hsiao-Wen; Chu, Sheng-Hsien; Liu, Kuan-Lin; Lin, Kuo-Jen

    2012-01-01

    We report the outcomes of temporary vesicostomy- assisted anastomotic urethroplasty in patients with recurrent obliterated posterior urethral stricture. A review of the medical records identified 12 men (mean age 35.8 years) who had undergone anastomotic urethroplasty for recurrent obliterated posterior stricture. Preoperative evaluation of the urethral defect included a simultaneous retrograde urethrogram and cystogram. The mean estimated preoperative radiographic length of the urethral disruption was 4.25 cm. All patients underwent 1-stage bulboprostatic anastomotic repair which was assisted by an intraoperative temporary vesicostomy. The initial objective success rate was 83%. The mean follow-up was 22 months. Voiding cystourethrography performed postoperatively demonstrated a wide, patent anastomosis in all but two cases. Urethroscopy performed 1 month after surgery revealed a patent anastomosis with normal urethral mucosa in all but two patients. The mean peak flow rate at the last follow-up visit was 16.3 ml/s. Two patients developed an anastomotic stricture 6 weeks after surgery that was successfully treated by direct visual internal urethrotomy. Finally, all patients had a patent urethra after salvage treatment postoperatively. An open 1-stage temporary vesicostomy- assisted urethroplasty for recurrent obliterated posterior urethral stricture provides satisfactory outcomes and minimal morbidities.

  17. 45 CFR 170.490 - Sunset of the temporary certification program.

    Science.gov (United States)

    2010-10-01

    ... TECHNOLOGY HEALTH INFORMATION TECHNOLOGY STANDARDS, IMPLEMENTATION SPECIFICATIONS, AND CERTIFICATION CRITERIA AND CERTIFICATION PROGRAMS FOR HEALTH INFORMATION TECHNOLOGY Temporary Certification Program for HIT...

  18. 78 FR 23952 - Notice of Temporary Closure on Public Lands in Elmore County, ID

    Science.gov (United States)

    2013-04-23

    ...] Notice of Temporary Closure on Public Lands in Elmore County, ID AGENCY: Bureau of Land Management, Interior. ACTION: Notice of temporary closure. SUMMARY: Notice is hereby given that the Stout Fire closure to motorized vehicle use is in effect on public lands administered by the Four Rivers Field Office...

  19. [Effect of the sociodemographic, occupational, organisational and environmental variables on the duration of temporary sick leave in Spain].

    Science.gov (United States)

    Villaplana García, María; Sáez Navarro, Concepción; Meseguer de Pedro, Mariano; García-Izquierdo, Mariano

    2015-02-01

    This study examines the relationship, and relevance of the effect between the duration of the cases of temporary sick leave, as an indicator of absenteeism, and several characteristics (sociodemographic, labor, organizational and the environment) of workers covered by the Social Security System in Spain. A retrospective analysis was conducted on 598,988 processes, between 15 and 365days. The relationships between length of absence, and several characteristics such as demographic, sociodemographic, occupational, organizational and environment characteristics were determined (using P values). The mean duration for each of the features is described, and the size effect is calculated to estimate the importance of the relationships found. There were significant relationships between the duration of temporary sick leave and several demographic characteristics (gender, age, nationality and length of service), occupational (wages, type of contract), organizational (economic sector, activity and size company), the environmental (region, state) characteristics. The age also showed a significant size effect (rxy=.134), especially after age 44. Only age had a significance effect on the duration of work absence, although there was also a relationship with the rest of the demographic, occupational and work environment characteristics. There was also evidence of a cross-effects between the variables, which could cause errors in interpreting the results. Copyright © 2013 Elsevier España, S.L.U. All rights reserved.

  20. 78 FR 33216 - Temporary Change of Dates for Recurring Marine Event in the Fifth Coast Guard District, Mattaponi...

    Science.gov (United States)

    2013-06-04

    ... 1625-AA08 Temporary Change of Dates for Recurring Marine Event in the Fifth Coast Guard District, Mattaponi Drag Boat Race, Mattaponi River; Wakema, VA AGENCY: Coast Guard, DHS. ACTION: Temporary final rule. SUMMARY: The Coast Guard is establishing a temporary change to the enforcement period of special local...

  1. 78 FR 20135 - Notice of Temporary Closure on Public Lands in Boise County, ID

    Science.gov (United States)

    2013-04-03

    ...] Notice of Temporary Closure on Public Lands in Boise County, ID AGENCY: Bureau of Land Management, Interior. ACTION: Notice of Temporary Closure SUMMARY: Notice is hereby given that the Springs Fire closure to all human use is in effect on public lands administered by the Four Rivers Field Office, Bureau of...

  2. Developing a novel approach to analyse the regimes of temporary streams and their controls on aquatic biota

    Science.gov (United States)

    Gallart, F.; Prat, N.; García-Roger, E. M.; Latron, J.; Rieradevall, M.; Llorens, P.; Barberá, G. G.; Brito, D.; de Girolamo, A. M.; Lo Porto, A.; Neves, R.; Nikolaidis, N. P.; Perrin, J. L.; Querner, E. P.; Quiñonero, J. M.; Tournoud, M. G.; Tzoraki, O.; Froebrich, J.

    2011-10-01

    Temporary streams are those water courses that undergo the recurrent cessation of flow or the complete drying of their channel. The biological communities in temporary stream reaches are strongly dependent on the temporal changes of the aquatic habitats determined by the hydrological conditions. The use of the aquatic fauna structural and functional characteristics to assess the ecological quality of a temporary stream reach can not therefore be made without taking into account the controls imposed by the hydrological regime. This paper develops some methods for analysing temporary streams' aquatic regimes, based on the definition of six aquatic states that summarize the sets of mesohabitats occurring on a given reach at a particular moment, depending on the hydrological conditions: flood, riffles, connected, pools, dry and arid. We used the water discharge records from gauging stations or simulations using rainfall-runoff models to infer the temporal patterns of occurrence of these states using the developed aquatic states frequency graph. The visual analysis of this graph is complemented by the development of two metrics based on the permanence of flow and the seasonal predictability of zero flow periods. Finally, a classification of the aquatic regimes of temporary streams in terms of their influence over the development of aquatic life is put forward, defining Permanent, Temporary-pools, Temporary-dry and Episodic regime types. All these methods were tested with data from eight temporary streams around the Mediterranean from MIRAGE project and its application was a precondition to assess the ecological quality of these streams using the current methods prescribed in the European Water Framework Directive for macroinvertebrate communities.

  3. Occupational Safety and Health in the Temporary Services Industry: A Model for a Community-University Partnership.

    Science.gov (United States)

    Bonney, Tessa; Forst, Linda; Rivers, Samara; Love, Marsha; Pratap, Preethi; Bell, Tim; Fulkerson, Sean

    2017-08-01

    Workers in the temporary staffing industry face hazardous working conditions and have a high risk of occupational injury. This project brought together local workers' centers and university investigators to build a corps of Occupational Health Promoters (OHPs) and to test a survey tool and recruitment methods to identify hazards and raise awareness among workers employed by temporary staffing companies. OHPs interviewed ninety-eight workers employed by thirty-three temporary agencies and forty-nine client companies, working mainly in shipping and packing, manufacturing, and warehousing sectors. Surveys identified workplace hazards. OHPs reported two companies to OSHA, resulting in several citations. Partners reported greater understanding of occupational safety and health challenges for temporary workers and continue to engage in training, peer education, and coalition building.

  4. Influence of Screw Length and Bone Thickness on the Stability of Temporary Implants

    Directory of Open Access Journals (Sweden)

    Daniel Jogaib Fernandes

    2015-09-01

    Full Text Available The purpose of this work was to study the influence of screw length and bone thickness on the stability of temporary implants. A total of 96 self-drilling temporary screws with two different lengths were inserted into polyurethane blocks (n = 66, bovine femurs (n = 18 and rabbit tibia (n = 12 with different cortical thicknesses (1 to 8 mm. Screws insertion in polyurethane blocks was assisted by a universal testing machine, torque peaks were collected by a digital torquemeter and bone thickness was monitored by micro-CT. The results showed that the insertion torque was significantly increased with the thickness of cortical bone from polyurethane (p < 0.0001, bovine (p = 0.0035 and rabbit (p < 0.05 sources. Cancellous bone improved significantly the mechanical implant stability. Insertion torque and insertion strength was successfully moduled by equations, based on the cortical/cancellous bone behavior. Based on the results, insertion torque and bone strength can be estimate in order to prevent failure of the cortical layer during temporary screw placement. The stability provided by a cortical thickness of 2 or 1 mm coupled to cancellous bone was deemed sufficient for temporary implants stability.

  5. Temporary over voltages in the high voltage networks

    International Nuclear Information System (INIS)

    Vukelja, Petar; Naumov, Radomir; Mrvic, Jovan; Minovski, Risto

    2001-01-01

    The paper treats the temporary over voltages that may arise in the high voltage networks as a result of: ground faults, loss of load, loss of one or two phases and switching operation. Based on the analysis, the measures for their limitation are proposed. (Original)

  6. Operadores de bases de datos temporales y su implementación Temporary database operators and their implementation

    Directory of Open Access Journals (Sweden)

    Ángela María Castaño Restrepo

    2008-07-01

    Full Text Available Actualmente, los Sistemas de Gestión de Bases de Datos (SGBD comerciales no soportan adecuadamente las bases de datos temporales. Por ejemplo, el planteamiento de consultas temporales es difícil de expresar. En este artículo se discuten los aspectos referentes a la implementación de operadores temporales con el fin de facilitar la gestión de los datos temporales en un SGBD. Además, se presenta un caso de estudio para ejemplificar los operadores temporales implementados.Nowadays commercial Database Management Systems (DBMS do not offer an appropriate support for temporary databases. For example, the formulation of temporary consultations is a difficult task. In this paper, we discuss an implementation of temporary operators in order to facilitate the management of temporary data in a DBMS. In addition, we present a case study that illustrates the implemented temporary operators.

  7. Association of temporary complete AV block and junctional ectopic tachycardia after surgery for congenital heart disease

    International Nuclear Information System (INIS)

    Paech, Christian; Dähnert, Ingo; Kostelka, Martin; Mende, Meinhardt; Gebauer, Roman

    2015-01-01

    Junctional ectopic tachycardia (JET) is a postoperative complication with a mortality rate of up to 14% after surgery for congenital heart disease. This study evaluated the risk factors of JET and explored the association of postoperative temporary third degree atrioventricular (AV) block and the occurrence of JET. Data were collected retrospectively from 1158 patients who underwent surgery for congenital heart disease. The overall incidence of JET was 2.8%. Temporary third degree AV block occurred in 1.6% of cases. Permanent third degree AV block requiring pacemaker implantation occurred in 1% of cases. In all, 56% of patients with JET had temporary AV block (P < 0.001), whereas no case of postoperative JET was reported in patients with permanent AV block (P = 0.56). temporary third degree AV block did not suffer from JET. A correlation between temporary third degree AV block and postoperative JET could be observed. The risk factors identified for JET include younger age groups at the time of surgery, longer aortic cross clamping time and surgical procedures in proximity to the AV node

  8. THE MEANINGS OF DWELLING ATTRIBUTES FOR TEMPORARY RESIDENTS FROM DIFFERENT CULTURES: THE CASE OF KOREAN TEMPORARY RESIDENTS IN THE UNITED STATES

    Directory of Open Access Journals (Sweden)

    Eunsil Lee

    2010-03-01

    Full Text Available The cross-cultural temporary resident population is one of the fastest growing cultural groups in the United States. However, their housing experiences in the new environment have not been extensively studied. Thus, the current study sought to examine meanings of dwelling attributes for cross-cultural temporary residents in the host country. In order to obtain insights into not only functional meanings but also underlying values, a conceptual framework was developed based primarily on Gutman’s (1982 means-end theory and Rapoport’s (1988 three levels of meaning. A case study was conducted using indepth laddering interviews with ten Korean temporary residents in the Lansing, Michigan, area. Seven dwelling attributes emerged from interviews: two satisfactory attributes (i.e., surrounding natural environment and architecture and five unsatisfactory attributes (i.e., carpeted floor, interior lighting, acoustics, bathroom, and entryway. Data were analyzed utilizing the measurement of means-end chain (Gutman, 1982, identifying the lower-level, everyday meanings as well as middle-level, latent meanings of dwelling attributes. A hierarchical value map was used to illustrate the interrelationships among the attributes, consequences, and values. Results revealed that dwelling attributes in participants’ current housing did not effectively satisfy their fundamental needs. In particular, carpeted floor was linked to the greatest number of negative meanings. Moreover, the cultural aspects of Korean housing affected the meanings of dwelling attributes in participants’ current homes. Findings suggest design professionals, facility managers, and policymakers must understand how people from other cultures attach different meanings to the dwelling attributes in their homes and provide more culturally responsive residential environments.

  9. The contribution of temporary storage and executive processes to category learning.

    Science.gov (United States)

    Wang, Tengfei; Ren, Xuezhu; Schweizer, Karl

    2015-09-01

    Three distinctly different working memory processes, temporary storage, mental shifting and inhibition, were proposed to account for individual differences in category learning. A sample of 213 participants completed a classic category learning task and two working memory tasks that were experimentally manipulated for tapping specific working memory processes. Fixed-links models were used to decompose data of the category learning task into two independent components representing basic performance and improvement in performance in category learning. Processes of working memory were also represented by fixed-links models. In a next step the three working memory processes were linked to components of category learning. Results from modeling analyses indicated that temporary storage had a significant effect on basic performance and shifting had a moderate effect on improvement in performance. In contrast, inhibition showed no effect on any component of the category learning task. These results suggest that temporary storage and the shifting process play different roles in the course of acquiring new categories. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. 76 FR 78739 - Agency Information Collection (Regulation on Application for Fisher Houses and Other Temporary...

    Science.gov (United States)

    2011-12-19

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0630] Agency Information Collection (Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher House Application... INFORMATION: Title: Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher...

  11. 75 FR 4626 - Order Granting a Temporary Exemption From Certain Government Securities Act Provisions and...

    Science.gov (United States)

    2010-01-28

    ... DEPARTMENT OF THE TREASURY Order Granting a Temporary Exemption From Certain Government Securities... Department of the Treasury (Treasury) is issuing a temporary exemption from certain Government Securities Act... accommodate customer clearing of credit default swaps that reference government securities. Treasury is also...

  12. Efficacy of balloon temporary occlusion and intraoperative DSA in surgically difficult aneurysm

    International Nuclear Information System (INIS)

    Ezura, Masayuki; Mizoi, Kazuo; Yoshimoto, Takashi; Takahashi, Akira.

    1993-01-01

    A digital subtraction angiographic (DSA) apparatus has been installed in one of our operating rooms since April 1987. We performed intraoperative DSA in 42 aneurysmal surgeries in 38 patients and balloon temporary occlusion in 33 surgeries. The aneurysm was on an internal carotid artery in 26 cases and on the vertebro-basilar system in 16. A heparin-coated catheter (Anthron, Toray, Tokyo), 6 french in diameter, was inserted transfemorally and was put in a parent artery under general anesthesia. A balloon was temporarily inflated to determine inflation volume. The balloon catheter was soon deflated and was drawn back into the introducing catheter to avoid developing microembolus. The patients were not systemically heparinized but the introducing catheters were slowly flushed with heparinized saline during operation. Then a craniotomy was carried out. Next DSA was performed when temporary occlusion or confirmation of clipping was necessary. In cases of balloon temporary occlusion, the operating field was not obstructed as it is when a temporary clip is used, despite adequate flow reduction of the parent artery. After DSA for confirmation of clipping adjustment of it was performed in 12 cases out of 42. No complications occurred due to use of an introducing or a balloon catheter. We conclude that combined intravascular and neurosurgical approach, particularly for the large aneurysms with the difficulty of proximal control, can be a useful method of treatment. (author)

  13. Temporary agency work, migration and the crisis in Greece: labour market segmentation intensified.

    Science.gov (United States)

    Maroukis, Thanos

    2016-05-01

    This article focuses on the under-researched temporary agency employment in Greece. It shows that the development of the temporary employment agency sector has gone hand in hand with the flow of undocumented and exploitable migrant labour in Greece over the past 25 years, reflecting the segmentation of the Greek labour market along ethnic lines. Using empirical research evidence on the operation of temporary employment agencies in the Greek hospitality and health care sectors, the article highlights the precarious or even illicit nature of agency employment in a context in which labour outsourcing and flexible employment are promoted by policy-makers. Last but not least, it suggests that the segmented landscape of the Greek labour market has become more complex during the economic crisis, with more and more Greeks drawn to agency-mediated precarious employment.

  14. Characterizing temporary hydrological regimes at a European scale

    NARCIS (Netherlands)

    Kirkby, M.J.; Gallart, F.; Kjeldsen, T.R.; Irvine, B.J.; Froebrich, J.; Porto, Lo A.

    2011-01-01

    Monthly duration curves have been constructed from climate data across Europe to help address the relative frequency of ecologically critical low flow stages in temporary rivers, when flow persists only in disconnected pools in the river bed. The hydrological model is 5 based on a partitioning of

  15. 41 CFR 101-1.103 - FPMR temporary regulations.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true FPMR temporary regulations. 101-1.103 Section 101-1.103 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101...

  16. 41 CFR 115-1.103 - Temporary-type FPMR.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Temporary-type FPMR. 115-1.103 Section 115-1.103 Public Contracts and Property Management Federal Property Management Regulations System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1...

  17. Early closure of temporary ileostomy--the EASY trial

    DEFF Research Database (Denmark)

    Danielsen, Anne Kjaergaard; Correa-Marinez, Adiela; Angenete, Eva

    2011-01-01

    Reversal of a temporary ileostomy is generally associated with a low morbidity and mortality. However, ostomy reversal may cause complications requiring reoperation with subsequent major complications, in ranges from 0% to 7-9% and minor complications varying from 4-5% to 30%. Based on studies exploring...

  18. 36 CFR 223.37 - Revegetation of temporary roads.

    Science.gov (United States)

    2010-07-01

    ... roads. 223.37 Section 223.37 Parks, Forests, and Public Property FOREST SERVICE, DEPARTMENT OF... Provisions § 223.37 Revegetation of temporary roads. Timber sale contracts, permits and other documents... roads constructed or used thereunder so as to permit the reestablishment by artificial or natural means...

  19. 26 CFR 1.61-2T - Taxation of fringe benefits-1985 through 1988 (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Taxation of fringe benefits-1985 through 1988 (temporary). 1.61-2T Section 1.61-2T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY..., and Taxable Income § 1.61-2T Taxation of fringe benefits—1985 through 1988 (temporary). (a) Fringe...

  20. From the Social Shaping of Technology to the Staging of Temporary Spaces of Innovation

    DEFF Research Database (Denmark)

    Clausen, Christian; Gunn, Wendy

    2015-01-01

    This paper addresses recent developments within the social shaping perspective, specifically the forward-looking and political dimensions of intervening in processes of innovation. With a focus on the concept of 'temporary spaces’ as an analytical framework we present a study of a case on partici......This paper addresses recent developments within the social shaping perspective, specifically the forward-looking and political dimensions of intervening in processes of innovation. With a focus on the concept of 'temporary spaces’ as an analytical framework we present a study of a case...... on participatory innovation concerned with indoor climate practices in the building sector. Based on an analysis of the travel and uptake of narratives derived from field studies in industrial and research environments, we discuss the role of intermediaries such as ethnographic provocations concerning user...... practices in the staging of these temporary spaces. While the direct uptake of qualitative knowledge on user practice in the engineering worlds of indoor climate is limited, the paper highlights the role of staging temporary spaces and intermediary objects in collaboration with stakeholders as a way...

  1. From the social shaping of technology to the staging of temporary spaces of innovation

    DEFF Research Database (Denmark)

    Clausen, Christian; Gunn, Wendy

    2014-01-01

    This paper addresses recent developments within the social shaping perspective, specifically the forward-looking and political dimensions of intervening in processes of innovation. With a focus on the concept of ‘temporary spaces’ as an analytical framework we present a study of a case on partici......This paper addresses recent developments within the social shaping perspective, specifically the forward-looking and political dimensions of intervening in processes of innovation. With a focus on the concept of ‘temporary spaces’ as an analytical framework we present a study of a case...... on participatory innovation concerned with indoor climate practices in the building sector. Based on an analysis of the travel and uptake of narratives derived from field studies in industrial and research environments, we discuss the role of intermediaries such as ethnographic provocations concerning user...... practices in the staging of these temporary spaces. While the direct uptake of qualitative knowledge on user practice in the engineering worlds of indoor climate is limited, the paper highlights the role of staging temporary spaces and intermediary objects in collaboration with stakeholders as a way...

  2. Temporary Life Changes and the Timing of Divorce.

    Science.gov (United States)

    Fallesen, Peter; Breen, Richard

    2016-10-01

    Marriage is a risky undertaking that people enter with incomplete information about their partner and their future life circumstances. A large literature has shown how new information gained from unforeseen but long-lasting or permanent changes in life circumstances may trigger a divorce. We extend this literature by considering how information gained from a temporary change in life circumstances-in our case, a couple having a child with infantile colic-may affect divorce behavior. Although persistent life changes are known to induce divorce, we argue that a temporary stressful situation allows couples more quickly to discern the quality of their relationship, in some cases leading them to divorce sooner than they otherwise would have. We formalize this argument in a model of Bayesian updating and test it using data from Denmark. We find that the incidence of infantile colic shortens the time to divorce or disruption among couples who would have split up anyway.

  3. 77 FR 34935 - Foreign-Trade Zone 161; Temporary/Interim Manufacturing Authority; Siemens Energy, Inc., (Wind...

    Science.gov (United States)

    2012-06-12

    ... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Docket T-4-2012] Foreign-Trade Zone 161; Temporary/Interim Manufacturing Authority; Siemens Energy, Inc., (Wind Turbine Nacelles and Hubs); Notice of... temporary/interim manufacturing (T/IM) authority, on behalf of Siemens Energy, Inc., to manufacture wind...

  4. A blockchain-based Decentralized System for proper handling of temporary Employment contracts

    OpenAIRE

    Pinna, Andrea; Ibba, Simona

    2017-01-01

    Temporary work is an employment situation useful and suitable in all occasions in which business needs to adjust more easily and quickly to workload fluctuations or maintain staffing flexibility. Temporary workers play therefore an important role in many companies, but this kind of activity is subject to a special form of legal protections and many aspects and risks must be taken into account both employers and employees. In this work we propose a blockchain-based system that aims to ensure r...

  5. Managing commercial low-level radioactive waste beyond 1992: Issues and potential problems of temporary storage

    International Nuclear Information System (INIS)

    Kerr, T.A.

    1991-01-01

    In accordance with the Low-Level Radioactive Waste Policy Amendments Act of 1985, States will become responsible for managing low-level radioactive waste, including mixed waste, generated within their borders as of January 1, 1993. In response to this mandate, many States and compact regions have made substantial progress toward establishing new disposal capacity for these wastes. While this progress is noteworthy, many circumstances can adversely affect States' abilities to meet the 1993 deadline, and many States have indicated that they are considering other waste management options in order to fulfill their responsibilities beyond 1992. Among the options that States are considering for the interim management of low- level radioactive waste is temporary storage. Temporary storage may be either short term or long term and may be at a centralized temporary storage facility provided by the State or a contractor, or may be at the point of generation or collection. Whether States choose to establish a centralized temporary storage facility or choose to rely on generators or brokers to provide additional and problem areas that must be addressed and resolved. Areas with many potential issues associated with the temporary storage of waste include: regulations, legislation, and policy and implementation guidance; economics; public participation; siting, design, and construction; operations; and closure and decommissioning

  6. Reactor cover gas monitoring at the Fast Flux Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Bechtold, R A; Holt, F E; Meadows, G E; Schenter, R E [Westinghouse Hanford Company, Richland, WA (United States)

    1987-07-01

    The Fast Flux Test Facility (FFTF) is a 400 megawatt (thermal) sodium cooled reactor designed for irradiation testing of fuels, materials and components for LMRs. It is operated by the Westinghouse Hanford Company for the U. S. Department of Energy on the government-owned Hanford reservation near Richland, Washington. The first 100 day operating cycle began in April 1982 and the eighth operating cycle was completed In July 1986. Argon is used as the cover gas for all sodium systems at the plant. A program for cover gas monitoring has been in effect since the start of sodium fill in 1978. The argon is supplied to the FFTF by a liquid argon Dewar System and used without further purification. A liquid argon Dewar system provides the large volume of inert gas required for operation of the FFTF. The gas is used as received and is not recycled. Low concentrations of krypton and xenon in the argon supply are essential to preclude interference with the gas tag system. Gas chromatography has been valuable for detection of inadvertent air in leakage during refueling operations. A temporary system is installed over the reactor during outages to prevent oxide formation in the sodium vapor traps upstream from the on line gas chromatograph. On line gas monitoring by gamma spectrometry and grab sampling with GTSTs has been successful for the identification of numerous radioactive gas releases from creep capsule experiments as well as 9 fuel pin ruptures. A redundant fission gas monitoring system has been installed to insure constant surveillance of the reactor cover gas.

  7. Hydrological Modeling in temporary streams: A case study in Pardiela basin, Southern Portugal

    OpenAIRE

    PEDRO, A.; MORAIS, M.; ROSADO, J.; SILVA, H.; SERAFIM, A.; NEVES, R.; BRITO, D.; POTES, M.; SALGADO, R.; LILLEBØ, I.; CHAMBEL, A.

    2011-01-01

    The project “Conservation and rehabilitation strategies for temporary Mediterranean river corridors: a case study on Pardiela basin, southern Portugal (Guadiana basin)", is being carried out,with the collaboration of researchers from diverse scientific areas, in order to increase the knowledge on temporary streams. The project includes different approaches at reach and basin scales, regarding the study of temporal interactions among different ecological components such as climate, morph...

  8. Island biogeography and landscape structure: Integrating ecological concepts in a landscape perspective of anthropogenic impacts in temporary wetlands

    International Nuclear Information System (INIS)

    Angeler, David G.; Alvarez-Cobelas, Miguel

    2005-01-01

    Although our understanding of environmental risk assessment in temporary wetlands has been improved by the use of multi-species toxicity testing, we still know little of how landscape variables mediate the strength of, and recovery from, anthropogenic stress in such ecosystems. To bridge this research gap, we provide a theoretical framework of the response of temporary wetlands to anthropogenic disturbance along a habitat-isolation continuum based on island biogeography theory, landscape ecology and dispersal and colonization strategies of temporary wetland organisms. - Environmental risk assessment in temporary wetlands may benefit from consideration of island biogeography theory and landscape structure

  9. USAGE OF PASTE FOR TEMPORARY PLACEMENT IN THE TREATMENT OF CHRONIC APICAL PERIODONTITIS

    Directory of Open Access Journals (Sweden)

    A.V. Borysenko

    2012-03-01

    Full Text Available Summary: The aim of the present investigation was usage of medicamental paste with antibacterial and regeneration action for temporary placement in the treatment of chronic apical periodontitis. Materials and method: The medicamental paste for temporary placement of root canals consists of a mixture of metronidazole, Enterosgel (Silm and Alflutop (Biotehnos S.A., Romania. Thë paste was used for the treatment of 30 teeth with chronic apical periodontitis. Final obturation of the root canals was performed with gutta percha cones and sealer. The efficiency of the treatment was appreciated after examination on the basis of clinical and radiographic findings. Results: During the treatment of the 30 teeth, no exacerbations of the pathological process were recorded. Pain after obturation of the root canals was revealed in only 6 (20% of the treated teeth. No pain, pathologic changes of gingiva, good mastication efficiency in all teeth after treatment were revealed. Conclusions: The high clinical efficiency of the medicamental paste with antibacterial and regeneration action at the level of temporary root canals placement in the treatment of chronic apical periodontitis was shown. Keywords: chronic apical periodontitis, medicamental paste for temporary root canals placement, metronidazole, Enterosgel (Silm and Alflutop (Biotehnos S.A., Romania

  10. Is temporary employment related to health status? Analysis of the Northern Swedish Cohort.

    Science.gov (United States)

    Waenerlund, Anna-Karin; Virtanen, Pekka; Hammarström, Anne

    2011-07-01

    The aim of this study was to investigate whether temporary employment was related to non-optimal self-rated health and psychological distress at age 42 after adjustment for the same indicators at age 30, and to analyze the effects of job insecurity, low cash margin and high job strain on this relationship. A subcohort of the Northern Swedish Cohort that was employed at the 2007 follow-up survey (n = 907, response rate of 94%) was analyzed using data from 1995 and 2007 questionnaires. Temporary employees had a higher risk of both non-optimal self-rated health and psychological distress. After adjustment for non-optimal self-rated health at age 30 and psychological distress at age 30 as well as for sociodemographic variables, the odds ratios decreased but remained significant. However, after adjustment for job insecurity, high job strain and low cash margin the odds ratio dropped for non-optimal self-rated health but remained significant for psychological distress. Temporary employment may have adverse effects on self-rated health and psychological health after adjustment for previous health status and sociodemographic variables. Our findings indicate that low cash margin and job insecurity may partially mediate the association between temporary employment and health status.

  11. Need for relevant timescales when crediting temporary carbon storage

    DEFF Research Database (Denmark)

    Jørgensen, Susanne Vedel; Hauschild, Michael Zwicky

    2013-01-01

    carbon storage in carbon footprinting. Methods: Implications of using a 100-year accounting period is evaluated via a literature review study of the global carbon cycle, as well as by analysing the crediting approaches that are exemplified by the PAS 2050 scheme for crediting temporary carbon storage......-term climatic benefits is considered to require storage of carbon for at least thousand years. However, it has been proposed that there may exist tipping points for the atmospheric CO2 concentration beyond which irreversible climate changes occur. To reduce the risk of passing such tipping points, fast...... mitigation of the rise in atmospheric greenhouse gas concentration is required and in this perspective, shorter storage times may still provide climatic benefits. Conclusions: Both short- and long-term perspectives should be considered when crediting temporary carbon storage, addressing both acute effects...

  12. The potential contribution to climate change mitigation from temporary carbon storage in biomaterials

    DEFF Research Database (Denmark)

    Jørgensen, Susanne Vedel; Hauschild, Michael Zwicky; Nielsen, Per H.

    2015-01-01

    of biomaterials.The recently developed approach for quantifying the climate tipping potential (CTP) of emissions is used, with some adaption, to account for the value of temporary carbon storage. CTP values for short-, medium- and long-term carbon storage in chosen biomaterials are calculated for two possible...... future atmospheric greenhouse gas (GHG) concentration development scenarios. The potential magnitude of the temporary carbon storage in biomaterials is estimated by considering the global polymer production being biobased in the future.Both sets of CTP values show the same trend; storage which releases...... contributes with negative CTP values, which means mitigation. The longer the duration of the storage, the larger the mitigation potential.Temporary carbon storage in biomaterials has a potential for contributing to avoid or postpone the crossing of a climatic target level of 450 ppm CO2e, depending on GHG...

  13. Temporary agency work, migration and the crisis in Greece: labour market segmentation intensified

    Science.gov (United States)

    2016-01-01

    This article focuses on the under-researched temporary agency employment in Greece. It shows that the development of the temporary employment agency sector has gone hand in hand with the flow of undocumented and exploitable migrant labour in Greece over the past 25 years, reflecting the segmentation of the Greek labour market along ethnic lines. Using empirical research evidence on the operation of temporary employment agencies in the Greek hospitality and health care sectors, the article highlights the precarious or even illicit nature of agency employment in a context in which labour outsourcing and flexible employment are promoted by policy-makers. Last but not least, it suggests that the segmented landscape of the Greek labour market has become more complex during the economic crisis, with more and more Greeks drawn to agency-mediated precarious employment. PMID:27499601

  14. 76 FR 63355 - Proposed Information Collection (Regulation on Application for Fisher Houses and Other Temporary...

    Science.gov (United States)

    2011-10-12

    ... (Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher House Application... information technology. Title: Regulation on Application for Fisher Houses and Other Temporary Lodging and VHA Fisher House Application, VA Forms 10-0408 and 10-0408a. OMB Control Number: 2900-0630. Type of Review...

  15. 26 CFR 1.163-11T - Allocation of certain prepaid qualified mortgage insurance premiums (temporary).

    Science.gov (United States)

    2010-04-01

    ... insurance premiums (temporary). 1.163-11T Section 1.163-11T Internal Revenue INTERNAL REVENUE SERVICE... insurance premiums (temporary). (a) Allocation—(1) In general. As provided in section 163(h)(3)(E), premiums... section applies whether the qualified mortgage insurance premiums are paid in cash or are financed...

  16. Working together: critical care nurses experiences of temporary staffing within Swedish health care: A qualitative study.

    Science.gov (United States)

    Berg Jansson, Anna; Engström, Åsa

    2017-08-01

    The aim of this study is to describe critical care nurses (CCN's) experiences of working with or as temporary agency staff. This explorative qualitative study is based on interviews with five agency CCNs and five regular CCNs, a total of ten interviews, focusing on the interviewees' experiences of daily work and temporary agency staffing. The interviews were analysed manually and thematically following an inductive approach. Four themes that illustrate both similarities and differences between regular and temporary agency CCNs emerged: "working close to patients versus being responsible for everything", "teamwork versus independence", "both groups needed" and "opportunities and challenges". The study findings illustrate the complexity of the working situation for agency and regular staff in terms of the organisation and management of the temporary agency nurses and the opportunities and challenges faced by both groups. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Changes in Temporary Disability Reporting Following the Implementation of the Army Medical Readiness Transformation.

    Science.gov (United States)

    Sapp, Jason E; Cody, Matthew J; Douglas, Kevin M

    2018-02-07

    In November 2014, the U.S. Army held a readiness summit to address concerns about the accuracy of medical reporting systems. At the time, soldiers on temporary disability were tracked as a medical readiness classification (MRC) 3A or 3B. MRC 3A soldiers had a medical condition with recovery expected within 30 d and MRC 3B soldiers were expected to take longer than 30 d to recover. Both groups were considered "non-available" and presumably non-deployable. Starting June 1, 2016, with the implementation of the Army Medical Readiness Transformation, soldiers on temporary disability longer than 14 d began to be reported as MRC 3s and are considered "non-deployable." The purpose of this study is to compare the number of soldiers on temporary disability previously reported as MRC 3A and 3B to the number listed as MRC 3 under the new reporting system for a light infantry brigade and to quantify the types and relative percentage of medical conditions leading to temporary disability under the new system. This cross-sectional analysis was conducted between January 1 and December 31, 2016 at Fort Carson, Colorado and included all soldiers assigned to Second Brigade, Fourth Infantry Division. We calculated the average number and proportion of soldiers on temporary disability at any one time for the period prior to implementation of the new reporting system (January 1 through May 31, 2016) and compared this to the period after implementation on June 1, 2016. The difference between the two independent proportions was calculated along with the lower and upper limits of the 95% confidence interval for the difference. Between January 1 and May 31, 2016, the average number of soldiers on temporary disability at any one time was 186, accounting for 4.3% of the authorized unit strength. After June 1, 2016, the average number increased to 244 or 5.7%. The difference in the proportion of temporary profiles was 1.4% (95% confidence interval 0.43-2.3%). From June 1 through December 31

  18. Temporary streams in temperate zones: recognizing, monitoring and restoring transitional aquatic-terrestrial ecosystems

    OpenAIRE

    Stubbington, Rachel; England, Judy; Wood, Paul J.; Sefton, Catherine E.M.

    2017-01-01

    Temporary streams are defined by periodic flow cessation, and may experience partial or complete loss of surface water. The ecology and hydrology of these transitional aquatic-terrestrial ecosystems have received unprecedented attention in recent years. Research has focussed on the arid, semi-arid, and Mediterranean regions in which temporary systems are the dominant stream type, and those in cooler, wetter temperate regions with an oceanic climate influence are also receiving increasing atte...

  19. 77 FR 35855 - Safety Zone, Temporary Change for Recurring Fifth Coast Guard District Fireworks Displays...

    Science.gov (United States)

    2012-06-15

    ... 1625-AA00 Safety Zone, Temporary Change for Recurring Fifth Coast Guard District Fireworks Displays; Northwest Harbor (East Channel) and Tred Avon River, MD AGENCY: Coast Guard, DHS. ACTION: Temporary final... Channel), Patapsco River, and Tred Avon River during the event. DATES: This rule is effective from 8 p.m...

  20. 26 CFR 1.6045-1T - Returns of information of brokers and barter exchanges (temporary).

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 13 2010-04-01 2010-04-01 false Returns of information of brokers and barter exchanges (temporary). 1.6045-1T Section 1.6045-1T Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... of information of brokers and barter exchanges (temporary). (a)-(k) [Reserved] For further guidance...

  1. Exposure to temporary employment and job insecurity: a longitudinal study of the health effects.

    Science.gov (United States)

    Virtanen, Pekka; Janlert, Urban; Hammarström, Anne

    2011-08-01

    This study analysed interactions between job insecurity and temporary employment and health. We tested the violation hypothesis (whether permanent employment increases the health risk associated with job insecurity) and the intensification hypothesis (whether temporary employment increases the health risk associated with job insecurity) in a longitudinal setting. Previous research on this topic is scarce and based on cross-sectional data. A population cohort (n=1071) was surveyed at age 30 and age 42. Exposure to temporary employment during this 12-year period was elicited with a job-time matrix and measured as the score of 6-month periods. Exposure to job insecurity was measured according to the perceived threat of unemployment. Health at follow-up was assessed as optimal versus suboptimal self-rated health, sleep quality and mental health. In addition to sociodemographics and baseline health, the analyses were adjusted for exposure to unemployment, non-employment and self-employment during the 12-year period. 26% of participants had been exposed to temporary employment. The effect of job insecurity on health was the same in the exposed and unexposed groups, that is the violation hypothesis was not supported. Non-significant interactions between the exposures and all health outcomes also indicated null findings regarding the intensification hypothesis. These findings suggest that perceived job insecurity can lead to adverse health effects in both permanent and temporary employees. Policies should aim to improve work-related well-being by reducing job insecurity. Efforts towards 'flexicurity' are important, but it is equally important to remember that a significant proportion of employees with a permanent contract experience job insecurity.

  2. Simple Words and Fuzzy Zones: Early Directions for Temporary River Research in South Africa

    Science.gov (United States)

    Uys; O'Keeffe

    1997-07-01

    / Although a large proportion of South Africa's rivers are nonperennial, ecological research into these systems has only recently been initiated. Consequently, we have little verified information about the ecological functioning of these rivers or knowledge of how best to manage them. High water demands in a semiarid region results in the flow of most perennial rivers being altered from permanent to temporary in sections, through impoundment, land-use changes, abstraction, etc. Conversely, sections of many temporary rivers are altered to perennial as a result of interbasin transfers or may be exploited for surface water. Effective and appropriate management of these modifications must be based on sound scientific information, which requires intensified, directed research. We anticipate that temporary river research in South Africa will, of necessity, be driven primarily by short-term collaborative efforts and secondarily by long-term ecological studies. At the outset, a simple conceptual framework is required to encourage an appreciation of current views of the spatial and temporal dynamics of nonperennial rivers and of the variability and unpredictability that characterize these systems. We adopt the view that perennial and episodic/ephemeral rivers represent either end of a continuum, separated by a suite of intermediate flow regimes. A conceptual diagram of this continuum is presented. In the absence of a functional classification for temporary rivers, a descriptive terminology has been systematically devised in an attempt to standardize definition of the different types of river regimes encountered in the country. Present terminology lacks structure and commonly accepted working definitions. KEY WORDS: Temporary rivers; Intermittent rivers; Continuum; Terminology; Classification; Ecosystem management; South Africa

  3. 77 FR 28305 - Temporary Rule To Delay Start Date of 2012-2013 South Atlantic Black Sea Bass Commercial Fishing...

    Science.gov (United States)

    2012-05-14

    .... 120501426-2426-01] RIN 0648-BB98 Temporary Rule To Delay Start Date of 2012-2013 South Atlantic Black Sea... this temporary rule to delay the start date of the 2012-2013 fishing season for the commercial black... temporary rule delays the start date of the 2012-2013 commercial fishing season for black sea bass from June...

  4. Fate and monitoring of hazardous substances in temporary rivers

    NARCIS (Netherlands)

    Ademollo, N.; Capri, S.; Froebrich, J.; Patrolecco, L.; Polesello, S.; Puddu, A.; Rusconi, M.; Valsecchi, S.

    2011-01-01

    Under climate-change conditions, temporary rivers will be the dominant surface-water bodies of the Mediterranean region. In order to manage this kind of water body appropriately, it is necessary to understand the chemical and ecological processes that involve hazardous substances in these

  5. Understanding the development of temporary agency work in Europe

    NARCIS (Netherlands)

    B.A.S. Koene (Bas); J. Paauwe (Jaap); J.P.M. Groenewegen (John)

    2004-01-01

    textabstractThis article develops an explanatory framework for understanding the growth and development of temporary agency work (TAW) and the related industry. The analysis shows that explanations based on economic logic are helpful in understanding the choice of TAW in general. These explanations,

  6. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    Directory of Open Access Journals (Sweden)

    Canena Jorge Manuel

    2012-06-01

    Full Text Available Abstract Background Refractory benign esophageal strictures (RBESs have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs, biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs, for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10, biodegradable stents (n = 10 or FCSEMSs (12 weeks, n = 10. Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60% in the SEPS group, 2 (20% in the biodegradable group and 3 (30% in the FCSEMS group (P = 0.16. A total of 8/30 patients (26.6% were dysphagia-free after the end of follow-up: 1 (10% in the SEPS group, 3 (30% in the biodegradable group and 4 (40% in the FCSEMS group (P = 0.27. More reinterventions were required in the SEPS group (n = 24 than in the biodegradable group (n = 13 or the FCSEMS group (n = 13 (P = 0.24. Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011. Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence.

  7. Defining chemical status of a temporary Mediterranean River.

    Science.gov (United States)

    Skoulikidis, Nikolaos Th

    2008-07-01

    Although the majority of rivers and streams in the Mediterranean area are temporary, no particular attention is being paid for such systems in the Water Framework Directive (WFD). A typical temporal Mediterranean river, draining an intensively cultivated basin, was assessed for its chemical status. Elevated concentrations of nitrates and salts in river water as well as nutrients and heavy metals in river sediments have been attributed to agricultural land uses and practices and point sources of organic pollution. A scheme for the classification of the river's chemical status (within the ecological quality classification procedure) was applied by combining pollution parameters in groups according to related pressures. In light of the temporal hydrological regime and anthropogenic impacts, sediment chemical quality elements were considered, in addition to hydrochemical ones. Despite the extensive agricultural activities in the basin, the majority of the sites examined showed a good quality and only three of them were classified as moderate. For the classification of the chemical quality of temporary water bodies, there is a need to develop ecologically relevant salinity and sediment quality standards.

  8. AXIAL MODIFICATIONS OF PERMANENT LOWER MOLARS AFTER PREMATURE LOSSES OF TEMPORARY MOLARS.

    Science.gov (United States)

    Cernei, E R; Mavru, R B; Zetu, Irina Nicoleta

    2016-01-01

    The aim of our study was to determine the impact of premature loss of temporary lower molars upon the longitudinal axis of the first and second permanent molars. The study groups included 61 patients, 6-9 year olds with premature loss of primary molars and a control group of 24 patients with intact temporary teeth. We evaluated the angle between longitudinal axis of first and second lower permanent molars and occlusal plane. It was observed that premature loss of lower second deciduous molar modifies more the vertical axis of first and second permanent molars than the premature loss of first lower primary molar. Reducing space occurs mainly through mesial inclination of molars that separates the edentulous breach. Temporary loss of both lower first molars on the same quadrant causes an accelerated eruption of both premolars increasing the prevalence of eruption sequence: "4-5-3-7". The preservation of the occlusal morpho-functional complex using space maintainers mainly when the premature loss of the second primary molars occurs is the best interceptive treatment option.

  9. 75 FR 6883 - Temporary Agricultural Employment of H-2A Aliens in the United States

    Science.gov (United States)

    2010-02-12

    ... Division 29 CFR Part 501 Temporary Agricultural Employment of H-2A Aliens in the United States; Final Rule... Division 29 CFR Part 501 RIN 1205-AB55 Temporary Agricultural Employment of H-2A Aliens in the United... of the alien in such labor or services will not adversely affect the wages and working conditions of...

  10. 77 FR 47915 - Wheego Electric Cars, Inc.; Grant of Petition for Temporary Exemption From the Electronic...

    Science.gov (United States)

    2012-08-10

    ...-0013] Wheego Electric Cars, Inc.; Grant of Petition for Temporary Exemption From the Electronic.... SUMMARY: This notice grants the petition of Wheego Electric Cars, Inc. (Wheego) for the temporary... procedures in 49 CFR part 555, Wheego Electric Cars, Inc. (Wheego) submitted a petition dated August 15, 2011...

  11. 77 FR 31183 - Safety Zone, Temporary Change for Recurring Fireworks Display Within the Fifth Coast Guard...

    Science.gov (United States)

    2012-05-25

    ...-AA00 Safety Zone, Temporary Change for Recurring Fireworks Display Within the Fifth Coast Guard District, Pamlico River and Tar River; Washington, NC AGENCY: Coast Guard, DHS. ACTION: Temporary final... is intended to restrict vessel traffic in a portion of the Pamlico River and Tar River near...

  12. Soil and soil cover changes in spruce forests after final logging

    Directory of Open Access Journals (Sweden)

    E. M. Lapteva

    2015-10-01

    Full Text Available Soil cover transformation and changes of morphological and chemical properties of Albeluvisols in clear-cuttings of middle taiga spruce forests were studied. The observed changes in structure and properties of podzolic texturally-differentiated soils at cuttings of spruce forests in the middle taiga subzone do not cause their transition to any other soil type. Soil cover of secondary deciduous-coniferous forests which replace cut forests are characterized with a varied soil contour and a combination of the main type of podzolic soils under undisturbed spruce forests. The increased surface hydromorphism in cut areas causes formation of complicated sub-types of podzolic texturally differentiated soils (podzolic surface-gley soils with microprofile of podzol and enlarges their ratio (up to 35–38 % in soil cover structure. Temporary soil over-wetting at the initial (5–10 years stage of after-cutting self-restoring vegetation succession provides for soil gleyzation, improves yield and segregation of iron compounds, increases the migratory activity of humic substances. Low content and resources of total nitrogen in forest litters mark anthropogenic transformation processes of podzolic soils at this stage. Later (in 30–40 years after logging, soils in cut areas still retain signs of hydromorphism. Forest litters are denser, less acidic and thick with a low weight ratio of organic carbon as compared with Albeluvisols of undisturbed spruce forest. The upper mineral soil horizons under secondary deciduous-coniferous forests contain larger amounts of total iron, its mobile (oxalate-dissolvable components, and Fe-Mn-concretions.

  13. Chimera states in multi-strain epidemic models with temporary immunity

    Science.gov (United States)

    Bauer, Larissa; Bassett, Jason; Hövel, Philipp; Kyrychko, Yuliya N.; Blyuss, Konstantin B.

    2017-11-01

    We investigate a time-delayed epidemic model for multi-strain diseases with temporary immunity. In the absence of cross-immunity between strains, dynamics of each individual strain exhibit emergence and annihilation of limit cycles due to a Hopf bifurcation of the endemic equilibrium, and a saddle-node bifurcation of limit cycles depending on the time delay associated with duration of temporary immunity. Effects of all-to-all and non-local coupling topologies are systematically investigated by means of numerical simulations, and they suggest that cross-immunity is able to induce a diverse range of complex dynamical behaviors and synchronization patterns, including discrete traveling waves, solitary states, and amplitude chimeras. Interestingly, chimera states are observed for narrower cross-immunity kernels, which can have profound implications for understanding the dynamics of multi-strain diseases.

  14. Microseismicity in the SE Aegean using data of he temporary EGELADOS network

    Science.gov (United States)

    Brüstle, Andrea; Küperkoch, Ludger; Meier, Thomas; Friederich, Wolfgang; Egelados Working Group

    2010-05-01

    The temporary broadband EGELADOS network covered the entire Hellenic Subduction Zone from October 2005 to April 2007. Seismic events are detected and identified by an STA/LTA-trigger and a grid-search algorithm, where relative travel times of pre-defined masterevents are compared to observed differential trigger times. Because of the high seismicity, we will focus on this poster on the south-eastern part of the Hellenic Subduction Zone including the forearc around Rhodes, Karpathos and Kassos and the volcanic arc around Nisyros. In addition, the considered region covers the transition zone from the Aegean to the Anatolian microplates at the west coast of Turkey. In this region we have located more than 3500 local earthquakes in 13 months of the network. Microseismicity down to a magnitude of about ML 1.8 is detected completely. In regions with an increased station density, microseismicity may be observed completely down to magnitudes of ML 1. High shallow microseismicity is observed in the forearc with clusters southeast of Crete (Ptolemy trench), south of Karpathos and southwest of Amorgos within the volcanic arc. A continuous seismically active zone strikes along the EW trending rift of the Gulf of Goekova to western Kos and changes its direction to NS by crossing the volcanic island Nisyros and extruding into the forearc near Kassos. Intermediate depth seismicity of the subducting slab is located in the volcanic arc between Astypalea and Tilos. The strong attenuation of the S-waves of intermediate depth events points to low Q in the mantle wedge above the subducting African lithosphere. In contrast, S-waves propagating within the slab from the source to the stations in the forearc are much less attenuated.

  15. Mechanical properties of materials used for temporary fixed dentures – in vitro study

    Directory of Open Access Journals (Sweden)

    Celej-Piszcz Elzbieta

    2017-06-01

    Full Text Available Objectives. The objective of the research was to define the mechanical properties of currently marketed temporary filling materials. Methods. Eight temporary filling materials: Boston, Dentalon, Protemp II, Revotek LC, Structure 2, Structure 3, UniFast LC, UniFast Trad were used to make 5 samples each of measurements 2 × 2 × 25 mm, in order to define the flexural strength, and 10 rings each of measurements 2 × 5 mm, in order to carry out the Vickers micro-hardness test. After preparation, the samples were stored in distilled water of temperature of 370°C, for 7 days. Subsequently, flexural strength and Vickers hardness testing was undertaken. Results. Composite temporary materials showed considerably better mechanical properties, both in flexural strength and in Vickers micro-hardness testing. Conclusions. the best mechanical properties, both in terms of flexural strength, as well as Vickers micro-hardness test can be observe among composite materials.

  16. Abundance and diversity of Odonata in temporary water bodies of Coimbatore and Salem districts in Tamil Nadu

    Directory of Open Access Journals (Sweden)

    R. Arulprakash

    2010-07-01

    Full Text Available Odonata diversity was assessed in 13 temporary water bodies of Coimbatore and Salem districts in Tamil Nadu. Assessment revealed the presence of 21 species of Odonata (14 species of Anisoptera and seven species of Zygoptera belonging to 17 genera under four families. Libellulidae (Anisoptera was represented by the maximum number of species and individuals. Pantala flavescens (Libellulidae was the most abundant among 21 species. Among the temporary water bodies, the maximum number of individuals as well as species was recorded from Utkulam tank (Coimbatore district. Odonata diversity was higher in Kamalapuram tanks 1 and 2 (Salem district and lower in Ukkadam tank (Coimbatore District. Diplacodes trivialis (Rambur, Orthetrum sabina (Drury and Pantala flavescens (Fabricius were identified as temporary water body specialists because of their presence in all the 13 temporary water bodies sampled.

  17. 77 FR 4623 - Wheego Electric Cars, Inc. Receipt of Petition for Temporary Exemption From the Electronic...

    Science.gov (United States)

    2012-01-30

    ...-0013] Wheego Electric Cars, Inc. Receipt of Petition for Temporary Exemption From the Electronic.... SUMMARY: In accordance with the procedures in 49 CFR part 555, Wheego Electric Cars, Inc., has petitioned... Electric Cars, Inc. (Wheego) submitted a petition dated August 15, 2011 asking the agency for a temporary...

  18. 22 CFR 96.99 - Converting an application for temporary accreditation to an application for full accreditation.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Converting an application for temporary accreditation to an application for full accreditation. 96.99 Section 96.99 Foreign Relations DEPARTMENT OF... INTERCOUNTRY ADOPTION ACT OF 2000 (IAA) Procedures and Standards Relating to Temporary Accreditation § 96.99...

  19. 76 FR 35508 - Alabama Southern Railroad, L.L.C.-Temporary Trackage Rights Exemption-Norfolk Southern Railway...

    Science.gov (United States)

    2011-06-17

    ... Railroad, L.L.C.--Temporary Trackage Rights Exemption--Norfolk Southern Railway Company Norfolk Southern... grant nonexclusive overhead temporary trackage rights to Alabama Southern Railroad, L.L.C. (ABS) over a... http://www.stb.dot.gov . Decided: June 13, 2011. By the Board. Rachel D. Campbell, Director, Office of...

  20. 76 FR 60124 - Tesla Motors, Inc.; Grant of Petition for Temporary Exemption From the Electronic Stability...

    Science.gov (United States)

    2011-09-28

    ...-0110] Tesla Motors, Inc.; Grant of Petition for Temporary Exemption From the Electronic Stability... notice grants the petition of Tesla Motors, Inc. (Tesla) for the temporary exemption of its Roadster... procedures in 49 CFR Part 555, Tesla Motors, Inc. (Tesla) submitted a petition dated June 7, 2011 asking the...

  1. Umbilical site for temporary colostomy in anorectal malformations: is ...

    African Journals Online (AJOL)

    Umbilical site for temporary colostomy in anorectal malformations: is it cosmetically preferable? Taha Alkhatrawi, Radi Elsherbini and Djamal Ouslimane. Purpose In an attempt to minimize the scars and improve the cosmetic outcome in children, the umbilical site has been chosen for colostomy formation in patients with.

  2. Plant experience with temporary reverse osmosis makeup water systems

    International Nuclear Information System (INIS)

    Polidoroff, C.

    1986-01-01

    Pacific Gas and Electric (PG and E) Company's Diablo Canyon Power Plant (DCPP), which is located on California's central coast, has access to three sources of raw water: creek water, well water, and seawater. Creek and well water are DCPP's primary sources of raw water; however, because their supply is limited, these sources are supplemented with seawater. The purpose of this paper is to discuss the temporary, rental, reverse osmosis systems used by PG and E to process DCPP's raw water into water suitable for plant makeup. This paper addresses the following issues: the selection of reverse osmosis over alternative water processing technologies; the decision to use vendor-operated temporary, rental, reverse osmosis equipment versus permanent PG and E-owned and -operated equipment; the performance of DCPP's rental reverse osmosis systems; and, the lessons learned from DCPP's reverse osmosis system rental experience that might be useful to other plants considering renting similar equipment

  3. Temporary provision against Kernkraftwerk Biblis dismissed

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    With its decision of November 19, 1979 - VIII IG 13/79 -, the Administrative Court of Hesse has refused the complaint of a Darmstadt resident whose application for a temporary provision interdicting further operation of the power plant units Biblis A and B had been refused by the Darmstadt Administrative Court. The costs of the procedure, including the extra-judicial costs of the witnesses heard, are to be paid by the plaintiff. The value in litigation was raised to DM 10 000,-. (orig./HP) 891 HP/orig.- 892 CKA [de

  4. Temporary Blindness after Inferior Alveolar Nerve Block.

    Science.gov (United States)

    Barodiya, Animesh; Thukral, Rishi; Agrawal, Shaila Mahendra; Rai, Anshul; Singh, Siddharth

    2017-03-01

    Inferior Alveolar Nerve Block (IANB) anaesthesia is one of the common procedures in dental clinic. This procedure is safe, but complications may still occur. Ocular complications such as diplopia, loss of vision, or ophthalmoplegia are extremely rare. This case report explains an event where due to individual anatomic variation of the sympathetic vasoconstrictor nerve and maxillary and middle meningeal arteries, intravascular administration of anaesthetic agent caused unusual ocular signs and symptoms such as temporary blindness.

  5. Vertebral Augmentation with Nitinol Endoprosthesis: Clinical Experience in 40 Patients with 1-Year Follow-up

    International Nuclear Information System (INIS)

    Anselmetti, Giovanni Carlo; Manca, Antonio; Marcia, Stefano; Chiara, Gabriele; Marini, Stefano; Baroud, Gamal; Regge, Daniele; Montemurro, Filippo

    2014-01-01

    PurposeThis study was designed to assess the clinical outcomes of patients treated by vertebral augmentation with nitinol endoprosthesis (VNE) to treat painful vertebral compression fractures.MethodsForty patients with one or more painful osteoporotic VCF, confirmed by MRI and accompanied by back-pain unresponsive to a minimum 2 months of conservative medical treatment, underwent VNE at 42 levels. Preoperative and postoperative pain measured with Visual Analog Scale (VAS), disability measured by Oswestry Disability Index (ODI), and vertebral height restoration (measured with 2-dimensional reconstruction CT) were compared at last follow-up (average follow-up 15 months). Cement extravasation, subsequent fractures, and implant migration were recorded.ResultsLong-term follow-up was obtained in 38 of 40 patients. Both VAS and ODI significantly improved from a median of 8.0 (range 5–10) and 66 % (range 44–88 %) to 0.5 (range 0–8) and 6 % (range 6–66 %), respectively, at 1 year (p < 0.0001). Vertebral height measurements comparing time points increased in a statistically significant manner (ANOVA, p < 0.001). Overall cement extravasation rate was 9.5 %. Discal and venous leakage rates were 7.1 and 0 % respectively. No symptomatic extravasations occurred. Five of 38 (13.1 %) patients experienced new spontaneous, osteoporotic fractures. No device change or migration was observed.ConclusionsVNE is a safe and effective procedure that is able to provide long-lasting pain relief and durable vertebral height gain with a low rate of new fractures and cement leakages

  6. Vertebral Augmentation with Nitinol Endoprosthesis: Clinical Experience in 40 Patients with 1-Year Follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Anselmetti, Giovanni Carlo, E-mail: gc.anselmetti@fastwebnet.it [Villa Maria Hospital, Interventional Radiology Unit (Italy); Manca, Antonio, E-mail: anto.manca@gmail.com [Institute for Cancer Research and Treatment (IRCC), Interventional Radiology Unit (Italy); Marcia, Stefano, E-mail: stemarcia@gmail.com [Institute of Radiology, University of Cagliari (Italy); Chiara, Gabriele, E-mail: gabriele.chiara@ircc.it [Institute for Cancer Research and Treatment (IRCC), Interventional Radiology Unit (Italy); Marini, Stefano, E-mail: stemarini@gmail.com [Institute of Radiology, University of Cagliari (Italy); Baroud, Gamal, E-mail: gamalbaroud@gmail.com [University of Sherbrooke, Departement de Genie Mecanique (Canada); Regge, Daniele, E-mail: daniele.regge@ircc.it [Institute for Cancer Research and Treatment (IRCC), Radiology Unit (Italy); Montemurro, Filippo, E-mail: filippo.montemurro@ircc.it [Institute for Cancer Research and Treatment (IRCC), Internal Medicine Unit (Italy)

    2013-05-08

    PurposeThis study was designed to assess the clinical outcomes of patients treated by vertebral augmentation with nitinol endoprosthesis (VNE) to treat painful vertebral compression fractures.MethodsForty patients with one or more painful osteoporotic VCF, confirmed by MRI and accompanied by back-pain unresponsive to a minimum 2 months of conservative medical treatment, underwent VNE at 42 levels. Preoperative and postoperative pain measured with Visual Analog Scale (VAS), disability measured by Oswestry Disability Index (ODI), and vertebral height restoration (measured with 2-dimensional reconstruction CT) were compared at last follow-up (average follow-up 15 months). Cement extravasation, subsequent fractures, and implant migration were recorded.ResultsLong-term follow-up was obtained in 38 of 40 patients. Both VAS and ODI significantly improved from a median of 8.0 (range 5–10) and 66 % (range 44–88 %) to 0.5 (range 0–8) and 6 % (range 6–66 %), respectively, at 1 year (p < 0.0001). Vertebral height measurements comparing time points increased in a statistically significant manner (ANOVA, p < 0.001). Overall cement extravasation rate was 9.5 %. Discal and venous leakage rates were 7.1 and 0 % respectively. No symptomatic extravasations occurred. Five of 38 (13.1 %) patients experienced new spontaneous, osteoporotic fractures. No device change or migration was observed.ConclusionsVNE is a safe and effective procedure that is able to provide long-lasting pain relief and durable vertebral height gain with a low rate of new fractures and cement leakages.

  7. Job insecurity and well-being in the temporary workforce : Testing volition and contract expectations as boundary conditions

    NARCIS (Netherlands)

    Bernhard-Oettel, C.; Rigotti, T.; Clinton, M.; de Jong, J.P.

    2013-01-01

    This study investigates whether temporary contract volition and workers' expectations for contract renewal are boundary conditions to explain differences in temporary workers' job insecurity feelings and well-being. It is hypothesized that (1) low volition through higher job insecurity indirectly

  8. 77 FR 14417 - Notice of Temporary Closure on Public Lands in Gooding and Elmore Counties, ID

    Science.gov (United States)

    2012-03-09

    ...] Notice of Temporary Closure on Public Lands in Gooding and Elmore Counties, ID AGENCY: Bureau of Land Management, Interior. ACTION: Notice of temporary closure. SUMMARY: Notice is hereby given that the Blair Fire closure to motorized vehicle use is in effect on public lands administered by the Four Rivers and...

  9. 77 FR 28764 - Temporary Non-agricultural Employment of H-2B Aliens in the United States

    Science.gov (United States)

    2012-05-16

    ... DEPARTMENT OF LABOR Employment and Training Administration 20 CFR Part 655 RIN 1205-AB58 Temporary Non-agricultural Employment of H-2B Aliens in the United States AGENCY: Employment and Training... Temporary Non-agricultural Employment of H-2B Aliens in the United States, published February 21, 2012 (the...

  10. Car Covers | Outdoor Covers Canada

    OpenAIRE

    Covers, Outdoor

    2018-01-01

    Protect your car from the elements with Ultimate Touch Car Cover. The multi-layer non-woven fabric is soft on the finish and offers 4 seasons all weather protection.https://outdoorcovers.ca/car-covers/

  11. Temporary and long-term consequences of bereavement on happiness

    NARCIS (Netherlands)

    Moor, J.A.; de Graaf, P.M.

    In this article, we examine the temporary and long-term consequences of the death of a parent or child on happiness. According to set-point theory external conditions are expected to only have a short-term or limited influence on happiness. This directly contradicts the basic assumption of affective

  12. Long-term follow-up of children thought to have temporary brittle bone disease

    Directory of Open Access Journals (Sweden)

    Paterson CR

    2011-06-01

    Full Text Available Colin R Paterson1, Elizabeth A Monk21Department of Medicine (retired, 2School of Accounting and Finance, University of Dundee, Dundee, ScotlandBackground: In addition to nonaccidental injury, a variety of bone disorders may underlie the finding of unexplained fractures in young children. One controversial postulated cause is temporary brittle bone disease, first described in 1990.Methods: Eighty-five patients with fractures showing clinical and radiological features of temporary brittle bone disease were the subject of judicial hearings to determine whether it was appropriate for them to return home. Sixty-three patients did, and follow-up information was available for 61 of these. The mean follow-up period was 6.9 years (range 1–17, median 6.Results: We found that none of the children had sustained any further injuries that were thought to represent nonaccidental injury; no child was re-removed from home. Three children had fractures. In each case there was general agreement that the fractures were accidental. Had the original fractures in these children been the result of nonaccidental injury, it would have been severe and repeated; the average number of fractures was 9.1.Conclusion: The fact that no subsequent suspicious injuries took place after return home is consistent with the view that the fractures were unlikely to have been caused by nonaccidental injury, and that temporary brittle bone disease is a distinctive and identifiable disorder.Keywords: fractures, osteogenesis imperfecta, temporary brittle bone disease, nonaccidental injury

  13. The open abdomen and temporary abdominal closure systems--historical evolution and systematic review.

    Science.gov (United States)

    Quyn, A J; Johnston, C; Hall, D; Chambers, A; Arapova, N; Ogston, S; Amin, A I

    2012-08-01

    Several techniques for temporary abdominal closure have been developed. We systematically review the literature on temporary abdominal closure to ascertain whether the method can be tailored to the indication. Medline, Embase, the Cochrane Central Register of Controlled Trials and relevant meeting abstracts until December 2009 were searched using the following headings: open abdomen, laparostomy, VAC (vacuum assisted closure), TNP (topical negative pressure), fascial closure, temporary abdominal closure, fascial dehiscence and deep wound dehiscence. The data were analysed by closure technique and aetiology. The primary end-points included delayed fascial closure and in-hospital mortality. The secondary end-points were intra-abdominal complications. The search identified 106 papers for inclusion. The techniques described were VAC (38 series), mesh/sheet (30 series), packing (15 series), Wittmann patch (eight series), Bogotá bag (six series), dynamic retention sutures (three series), zipper (15 series), skin only and locking device (one series each). The highest facial closure rates were seen with the Wittmann patch (78%), dynamic retention sutures (71%) and VAC (61%). Temporary abdominal closure has evolved from simple packing to VAC based systems. In the absence of sepsis Wittmann patch and VAC offered the best outcome. In its presence VAC had the highest delayed primary closure and the lowest mortality rates. However, due to data heterogeneity only limited conclusions can be drawn from this analysis. © 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.

  14. Code of practice for the temporary diversion of water from hydrostatic testing of pipelines: Water Act - Water (Ministerial) Regulation No. 205

    International Nuclear Information System (INIS)

    1999-01-01

    A series of administrative procedures are described in this regulation regarding the temporary diversion of water for hydrostatic testing of pipelines in Alberta. These include the notification and timing of the release of water, where the test will occur and the possible effect of water release on the environment. The requirements of a hydrostatic test plan are described in point form. In accordance with the regulation, a person responsible for the testing must ensure that the testing does not cause a significant adverse effect on the aquatic environment or on any household user. Should this occur, all adverse effects on the aquatic environment should be fully mitigated. The reporting schedule and record keeping information are also covered. 2 tabs., 1 figs

  15. A new intratracheal stent made from nitinol, an alloy with "shape memory effect".

    Science.gov (United States)

    Vinograd, I; Klin, B; Brosh, T; Weinberg, M; Flomenblit, Y; Nevo, Z

    1994-05-01

    Temporary or permanent tracheal splinting in pediatric patients may be indicated in tracheomalacia or bronchomalacia, repair of congenital tracheal stenosis, and after tracheal resection. This study presents the results of the development of a new intraluminal airway stent made from titanium alloy, a metal with "shape memory effect". At low temperatures (martensitic state) the titanium alloy stent can be fashioned into a specific shape; then when heated to a higher temperature (austenitic state) the stent alters its shape, only to regain its original shape when recooled to the lower temperature. The stent, connected to a small electric power supply, was introduced into 20 young rabbits with the use of a 2.5 cm rigid bronchoscope. After implantation in the martensitic state the stent was warmed to 40 degrees C, the austenitic state, by an electric current of 1.5 to 3 ampere for 1 to 2 seconds. After a period of 8 to 10 weeks the stent was removed (in its martensitic state) through the same-sized bronchoscope after being cooled with 3 to 4 ml of 80% alcohol solution at 6 degrees C. No signs of airway obstruction developed in any of the animals after implantation or extraction of the stent. The biomechanical properties of the trachea, as shown by strain measurements with the use of incremental forces, showed significant differences between the stented and unstented segments (p stent adequately fulfilled the requirements of a temporary intraluminal airway splint, and because of its unique feature of shape memory effect the stent could be inserted, fixed, and removed easily, even in very small airways.

  16. Temporary diplopia upon hyoscine-N-butyl bromide administration: case report

    Directory of Open Access Journals (Sweden)

    Migliorini R

    2013-05-01

    Full Text Available R Migliorini, R Malagola, M Mafrici, R Spena, L ArricoDepartment of Sense Organs, University of Rome "La Sapienza", Rome, ItalyAbstract: Hyoscine-N-butyl bromide is a widely used antispasmodic belonging to the belladonna alkaloid class of semisynthetic quaternary ammonium compounds. These compounds exert a spasmolytic action on the smooth muscles of the bile-gastrointestinal tract, genitourinary tract, salivary glands (xerostomia, and also on the visual apparatus – in particular, the irido-ciliary complex. As a consequence, they provoke collateral effects such as mydriasis and accommodation disturbances. We report the case of a 23-year-old woman who complained of not only "dry mouth" but also "cloudy vision" and a "diplopia", both of temporary type, 2 hours after oral administration of hyoscine-N-butyl bromide.Keywords: hyoscine-N-butyl bromide, accommodation disorders, temporary diplopia, fusion alteration, vertical strabismus

  17. 20 CFR 1002.41 - Does an employee have rights under USERRA even though he or she holds a temporary, part-time...

    Science.gov (United States)

    2010-04-01

    ... even though he or she holds a temporary, part-time, probationary, or seasonal employment position? 1002... employee have rights under USERRA even though he or she holds a temporary, part-time, probationary, or seasonal employment position? USERRA rights are not diminished because an employee holds a temporary, part...

  18. 78 FR 30914 - Grand River Dam Authority Notice of Application for Temporary Variance of License and Soliciting...

    Science.gov (United States)

    2013-05-23

    .... Description of Request: Grand River Dam Authority (GRDA) requests a temporary variance, for the year 2013, to... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 1494-416] Grand River Dam Authority Notice of Application for Temporary Variance of License and Soliciting Comments, Motions To...

  19. A biological tool to assess flow connectivity in reference temporary streams from the Mediterranean Basin

    Energy Technology Data Exchange (ETDEWEB)

    Cid, N., E-mail: ncid@ub.edu [Grup de Recerca “Freshwater Ecology and Management (FEM)”, Departament d' Ecologia, Universitat de Barcelona, Catalonia (Spain); Verkaik, I. [Grup de Recerca “Freshwater Ecology and Management (FEM)”, Departament d' Ecologia, Universitat de Barcelona, Catalonia (Spain); García-Roger, E.M. [Grup de Recerca “Freshwater Ecology and Management (FEM)”, Departament d' Ecologia, Universitat de Barcelona, Catalonia (Spain); Institut Cavanilles de Biodiversitat i Biologia Evolutiva, Universitat de València (Spain); Rieradevall, M.; Bonada, N. [Grup de Recerca “Freshwater Ecology and Management (FEM)”, Departament d' Ecologia, Universitat de Barcelona, Catalonia (Spain); Sánchez-Montoya, M.M. [Department of Ecology and Hydrology, Regional Campus of International Excellence “Campus Mare Nostrum”—University of Murcia (Spain); Leibniz-Institute of Freshwater Ecology and Inland Fisheries (IGB), Berlin (Germany); Gómez, R.; Suárez, M.L.; Vidal-Abarca, M.R. [Department of Ecology and Hydrology, Regional Campus of International Excellence “Campus Mare Nostrum”—University of Murcia (Spain); Demartini, D.; Buffagni, A.; Erba, S. [Instituto di Ricerca Sulle Acque (CNR-IRSA) (Italy); Karaouzas, I.; Skoulikidis, N. [Hellenic Center for Marine Research (HCMR) (Greece); Prat, N. [Grup de Recerca “Freshwater Ecology and Management (FEM)”, Departament d' Ecologia, Universitat de Barcelona, Catalonia (Spain)

    2016-01-01

    Many streams in the Mediterranean Basin have temporary flow regimes. While timing for seasonal drought is predictable, they undergo strong inter-annual variability in flow intensity. This high hydrological variability and associated ecological responses challenge the ecological status assessment of temporary streams, particularly when setting reference conditions. This study examined the effects of flow connectivity in aquatic macroinvertebrates from seven reference temporary streams across the Mediterranean Basin where hydrological variability and flow conditions are well studied. We tested for the effect of flow cessation on two streamflow indices and on community composition, and, by performing random forest and classification tree analyses we identified important biological predictors for classifying the aquatic state either as flowing or disconnected pools. Flow cessation was critical for one of the streamflow indices studied and for community composition. Macroinvertebrate families found to be important for classifying the aquatic state were Hydrophilidae, Simuliidae, Hydropsychidae, Planorbiidae, Heptageniidae and Gerridae. For biological traits, trait categories associated to feeding habits, food, locomotion and substrate relation were the most important and provided more accurate predictions compared to taxonomy. A combination of selected metrics and associated thresholds based on the most important biological predictors (i.e. Bio-AS Tool) were proposed in order to assess the aquatic state in reference temporary streams, especially in the absence of hydrological data. Although further development is needed, the tool can be of particular interest for monitoring, restoration, and conservation purposes, representing an important step towards an adequate management of temporary rivers not only in the Mediterranean Basin but also in other regions vulnerable to the effects of climate change. - Highlights: • The effect of flow connectivity on macroinvertebrate

  20. 17 CFR 201.540 - Appeal and Commission review of initial decision making a temporary order permanent.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false Appeal and Commission review of initial decision making a temporary order permanent. 201.540 Section 201.540 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION RULES OF PRACTICE Rules of Practice Rules Relating to Temporary Orders and Suspensions § 201.540...

  1. 38 CFR 36.4318 - Servicer tier ranking-temporary procedures.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Servicer tier ranking... § 36.4318 Servicer tier ranking—temporary procedures. (a) The Secretary shall assign to each servicer a “Tier Ranking” based upon the servicer's performance in servicing guaranteed loans. There shall be four...

  2. 20 CFR 655.34 - Validity of temporary labor certifications.

    Science.gov (United States)

    2010-04-01

    ... Attestations for Temporary Employment in Occupations Other Than Agriculture or Registered Nursing in the United... minor changes in the period of employment, only when a written request is submitted to the CO and... to make the labor certification determination required under § 655.32. (4) The CO may change the date...

  3. Temporary labour contracts

    CERN Document Server

    2000-01-01

    The five contracts for Temporary Labour assignments on the CERN site (L020/PE, L 021/PE, L 022/PE, L 023/PE and L 024/PE) approved by the Finance Committee in March 1996 (CERN/FC/3857) reached the end of their initial three-year contractual period at the end of December 1999. At CERN?s request, in September 1999 the Finance Committee approved an extension of these contracts for the year 2000 for a total amount not exceeding 6 000 000 Swiss francs (CERN/FC/4196). In December 1999, one of the five contractors, FIRCROFT, withdrew from its contract for 2000. Following the satisfactory execution of the four remaining contracts during 2000, CERN requests approval to extend them from January 2001 for the second of the two optional years provided for in the original adjudication. The Finance Committee is invited to approve the extension of the existing contracts until 31 December 2001 for a total amount not exceeding 6 000 000 Swiss francs at 2000 prices.

  4. 78 FR 23316 - The Royal Bank of Scotland plc, et al.; Notice of Application and Temporary Order

    Science.gov (United States)

    2013-04-18

    ... plc, et al.; Notice of Application and Temporary Order April 12, 2013. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Temporary order and notice of application for a permanent order under... application for a permanent order. Applicants have also applied for a permanent order. APPLICANTS: The Royal...

  5. 76 FR 16447 - ETHICON, a Subsidiary of Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary...

    Science.gov (United States)

    2011-03-23

    ... workers of ETHICON, A Johnson and Johnson Company, San Angelo, Texas, separated from employment on or... Johnson & Johnson Including On-Site Leased Workers From Kelly Temporary Services, San Angelo, TX; Amended... of ETHICON, a subsidiary of Johnson & Johnson, including on-site leased workers from Kelly Temporary...

  6. 77 FR 24225 - Information Collection Approval; Temporary Non-Agricultural Employment of H-2B Aliens in the...

    Science.gov (United States)

    2012-04-23

    ... DEPARTMENT OF LABOR Employment and Training Administration Information Collection Approval; Temporary Non-Agricultural Employment of H-2B Aliens in the United States AGENCY: Employment and Training... the Temporary Non-Agricultural Employment of H-2B Aliens in the United States; Final Rule. See 77 FR...

  7. 26 CFR 1.103(n)-1T - Limitation on aggregrate amount of private activity bonds (temporary).

    Science.gov (United States)

    2010-04-01

    ... activity bonds (temporary). 1.103(n)-1T Section 1.103(n)-1T Internal Revenue INTERNAL REVENUE SERVICE... Excluded from Gross Income § 1.103(n)-1T Limitation on aggregrate amount of private activity bonds (temporary). Q-1: What does section 103(n) provide? A-1: Interest on an issue of private activity bonds will...

  8. Determinants of self-efficacy and quality of life in patients with temporary enterostomy: a cross-sectional survey.

    Science.gov (United States)

    Su, Xi; Zhen, Li; Zhu, Mulan; Kuang, Yinyi; Qin, Fang; Ye, Xinmei; Yin, Xuexia; Wang, Huizhen

    2017-02-01

    To identify determinants of self-efficacy and quality of life in patients with temporary enterostomy. Anterior resection with temporary enterostomy is the preferred treatment for patients with rectal cancer, which may impair patients' quality of life. So far, most studies have focused on quality of life in patients with permanent enterostomy, but few studies have looked at that in those with temporary enterostomy. Self-efficacy may determine quality of life in these patients, but few studies have identified determinants of self-efficacy and quality of life. Multicentre, cross-sectional survey and regression analysis to identify determinants of self-efficacy and quality of life. A convenience sample of patients undergoing temporary enterostomy at five hospitals in Guangdong Province (China) were surveyed at least four weeks after stoma surgery using validated Chinese versions of internationally recognised questionnaires, including a Stoma Self-Efficacy Scale and the City of Hope Quality of Life-Ostomy Questionnaire. Backward multiple regression analysis was performed to identify whether quality of life was determined by self-efficacy and other clinico-demographic characteristics. Of the 180 questionnaires distributed, 149 (82·8%) were returned, and 135 (75%) were used in the final analysis. Mean global quality of life was 5·40 ± 1·58, and mean global self-efficacy was 79·59 ± 20·21. Significant determinants of self-efficacy and quality of life were identified (β = 0·62, p < 0·01). Quality of life was determined by type of enterostomy (β = 0·18, p = 0·01) and payment method (β = 0·14, p = 0·03). Quality of life may be determined by self-efficacy, type of enterostomy and payment method, after temporary enterostomy. Promoting stoma-related self-efficacy in patients with temporary enterostomy may improve their quality of life. Healthcare providers should focus on quality of life in those either with temporary loop ileostomy or entirely

  9. Language, Employment, and Settlement: Temporary Meat Workers in Australia

    Science.gov (United States)

    Piller, Ingrid; Lising, Loy

    2014-01-01

    Australia is one of the world's largest beef exporters. However, meat processing jobs are widely considered undesirable and are increasingly filled with employer-sponsored migrant workers on temporary long-stay visas. Against this background, our paper explores the role of language in the employment and migration trajectories of a group of meat…

  10. 26 CFR 1.897-5T - Corporate distributions (temporary).

    Science.gov (United States)

    2010-04-01

    ... also subject to the tax avoidance rules of § 1.897-6T(c). (b) Distributions by domestic corporations—(1... TAX (CONTINUED) INCOME TAXES Miscellaneous Provisions § 1.897-5T Corporate distributions (temporary...) Any U.S. tax paid by or on behalf of the distributee with respect to the distribution. (2...

  11. Factors affecting timing of closure and non-reversal of temporary ileostomies.

    Science.gov (United States)

    Sier, M F; van Gelder, L; Ubbink, D T; Bemelman, W A; Oostenbroek, R J

    2015-09-01

    Although stoma closure is considered a simple surgical intervention, the interval between construction and reversal is often prolonged, and some ileostomies may never be reversed. We evaluated possible predictors for non-reversal and prolonged interval between construction and reversal. In a cohort study of ileostomy patients treated in a large teaching hospital, we collected data from the surgical complication and enterostomal therapists' registries between January 2001 and December 2011. Parameters responsible for morbidity, mortality, length of stay and time interval between construction and reversal were analysed. Of 485 intentionally temporary ileostomies, 359 were reversed after a median of 5.6 months (IQR 3.8-8.9 months), while 126 (26%) remained permanent. End ileostomy and intra-abdominal abscess independently delayed reversal. Age, end ileostomy, higher body mass index and preoperative radiotherapy were independent factors for non-reversal. Median duration of hospitalisation for reversal was 7.0 days (5-13 days). Morbidity and mortality were 31 and 0.9%, respectively. In 20 patients (5.5%), re-ileostomy was necessary. A substantial number of ileostomies that are intended to be temporary will never be reversed. If reversed, the interval between construction and reversal is longer than anticipated, while morbidity after reversal and duration of hospitalisation are considerable. Besides a temporary ileostomy, there are two other options: no diversion or a permanent colostomy. Shared decision-making is to be preferred in these situations.

  12. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Leto, John; George, Christopher; Van Epps, Kelly; Woeste, Troy; Berlet, Mathew

    2008-01-01

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus

  13. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  14. Learning behavior and temporary minima of two-layer neural networks

    NARCIS (Netherlands)

    Annema, Anne J.; Hoen, Klaas; Hoen, Klaas; Wallinga, Hans

    1994-01-01

    This paper presents a mathematical analysis of the occurrence of temporary minima during training of a single-output, two-layer neural network, with learning according to the back-propagation algorithm. A new vector decomposition method is introduced, which simplifies the mathematical analysis of

  15. Diversity of micro-crustaceans in temporary habitats of the province ...

    African Journals Online (AJOL)

    ... and Eucypris virens (Ostracoda). Our results highlight the importance of temporary habitats as potential biodiversity hotspots, in spite of a few carried out by freshwater ecologists and taxonomists in undertaking scientific investigations in these environments. Key words: Ostracoda, cladocera, copepoda, biodiversity, Izmir, ...

  16. Managing temporary workers: work identity, diversity and operational HR choices

    NARCIS (Netherlands)

    Koene, Bas; van Riemsdijk, Maarten

    2005-01-01

    Strategic HRM theory argues that organisations should distinguish different types of employees according to their value and availability. We argue that this has resulted in an underestimation of the importance of specific HRM practices in relation to temporary employees. Building on theoretical work

  17. Temporary Piggyback Intraocular Lens Implantation Versus Single Intraocular Lens Implantation in Congenital Cataracts: Long-Term Clinical Outcomes.

    Science.gov (United States)

    Hwang, Sungsoon; Lim, Dong Hui; Lee, Soomin; Choi, Daye Diana; Chung, Eui-Sang; Chung, Tae-Young

    2018-04-01

    To report the long-term results of temporary piggyback IOL implantation in congenital cataract and to compare the clinical outcomes of temporary piggyback IOL with those of single IOL implantation. This is a retrospective, comparative, interventional study. The medical records of all consecutive patients who underwent cataract extraction and single or temporary piggyback IOL implantation within the first 3 years of life from 1999 to 2013 at Samsung Medical Center were reviewed. Twenty-eight eyes from 18 patients underwent single IOL implantation (monopseudophakia group), and 32 eyes of 20 patients underwent temporary piggyback IOL implantation in congenital cataract surgery (polypseudophakia group). The mean age at initial cataract surgery was 15.8 months in the monopseudophakia group and 11.1 months in the polypseudophakia group (P = 0.144). The average follow-up duration was 133 months in the monopseudophakia group and 120 months in the polypseudophakia group (P = 0.391). The best-corrected visual acuity at the last visit was 0.36 logMAR in the monopseudophakia group and 0.55 logMAR in the polypseudophakia group (P = 0.044). Four (14%) and 14 (44%) reoperations for complications within the anterior segment were performed in the monopseudophakia group and polypseudophakia group, respectively (P = 0.042). Four cases (14.3%) in the monopseudophakia group and 13 cases (40.6%) in the polypseudophakia group had a glaucoma-related adverse event (P = 0.086). Compared with primary single IOL implantation in congenital cataract, temporary piggyback IOL implantation produced worse visual acuity, higher reoperation rate, and higher risk of secondary glaucoma. Temporary piggyback IOL implantation does not have benefit in congenital cataract.

  18. Temporary new opening hours for Gate C

    CERN Multimedia

    GS Department

    2010-01-01

    Please note the new temporary opening hours for the gate C as from 22 September 2010 until 29 October 2010 (working days): Morning: between 7:00 a.m. and 9:00 a.m. Lunch: between 12:00 and 2:00 p.m. Evening: between 5:00 pm and 7:00 p.m. Traffic flow will be permitted in both directions during this period. Please minimize your speed accordingly and respect all road signs. GS-SEM Group General Infrastructure Services Department

  19. Institutional Logics in Inter-institutional Temporary Organizations

    DEFF Research Database (Denmark)

    Pemsel, Sofia; Söderlund, Jonas

    -cognitive, normative, and regulative – are unfolding and evolving in such contexts. The case study addresses the integration and disintegration of logics and normative orders in an ongoing process characterized by the co-mingling, co-existence, creation and resolutions of hybrid logics and creation of institutional...... exceptions throughout the life of the studied temporary organization. In that respect, this paper contributes with a more nuanced view on the evolution, dynamics, and co-existence of pressures from multiple institutional demands at the organizational level....

  20. Child health insurance coverage: a survey among temporary and permanent residents in Shanghai.

    Science.gov (United States)

    Lu, Mingshan; Zhang, Jing; Ma, Jin; Li, Bing; Quan, Hude

    2008-11-17

    Under the current healthcare system in China, there is no government-sponsored health insurance program for children. Children from families who move from rural and interior regions to large urban centres without a valid residency permit might be at higher risk of being uninsured due to their low socioeconomic status. We conducted a survey in Shanghai to describe children's health insurance coverage according to their migration status. Between 2005 and 2006, we conducted an in-person health survey of the adult care-givers of children aged 7 and under, residing in five districts of Shanghai. We compared uninsurance rates between temporary and permanent child residents, and investigated factors associated with child health uninsurance. Even though cooperative insurance eligibility has been extended to temporary residents of Shanghai, the uninsurance rate was significantly higher among temporary (65.6%) than permanent child residents (21.1%, adjusted odds ratio (OR): 5.85, 95% confidence interval (95% CI): 4.62-7.41). For both groups, family income was associated with having child health insurance; children in lower income families were more likely to be uninsured (OR: 1.96, 95% CI: 1.40-2.96). Children must rely on their parents to make the insurance purchase decision, which is constrained by their income and the perceived benefits of the insurance program. Children from migrant families are at even higher risk for uninsurance due to their lower socioeconomic status. Government initiatives specifically targeting temporary residents and providing health insurance benefits for their children are urgently needed.

  1. Microseismicity in the southeastern Aegean using data of the temporary EGELADOS network

    Science.gov (United States)

    Brüstle, A.; Küperkoch, L.; Meier, T.; Friederich, W.; Egelados Working Group

    2009-04-01

    The temporary broadband EGELADOS network covered the entire Hellenic Subduction Zone from October 2005 to April 2007. Seismic events are detected and identified by an STA/LTA-trigger and a grid-search algorithm, where relative travel times of pre-defined masterevents are compared to observed differential trigger times. Because of the high seismicity, we focus on the south-eastern part of the Hellenic Subduction Zone including the forearc around Rhodes, Karpathos and Kassos and the volcanic arc around Nisyros. In addition, the considered region covers the transition zone from the Aegean to the Anatolian microplates at the west coast of Turkey. For this region more than 1800 of the 2646 events, triggered during the first 6 months of the experiment, were identified as local earthquakes and localised. The other triggers represent earthquakes outside the working region, multiply triggered events, teleseismic events or noise, respectively. Microseismicity down to a magnitude of about ML 1.8 is detected completely. In regions with an increased station density, microseismicity may be observed completely down to magnitudes of ML 1. High shallow microseismicity is observed in the forearc with clusters southeast of Crete (Ptolemy trench), south of Karpathos and southwest of Amorgos within the volcanic arc. A continuous seismically active zone strikes along the EW trending rift of the Gulf of Gökova to western Kos and changes its direction to NS by crossing the volcanic island Nisyros and extruding into the forearc near Kassos. Intermediate depth seismicity of the subducting slab is located in the volcanic arc between Astypalea and Tilos. The strong attenuation of the S-waves of intermediate depth events points to low Q in the mantle wedge above the subducting African lithosphere. In contrast, S-waves propagating within the slab from the source to the stations in the forearc are much less attenuated.

  2. Ambient seismic noise levels: A survey of the permanent and temporary seismographic networks in Morocco, North Africa

    Science.gov (United States)

    El Fellah, Y.; Khairy Abd Ed-Aal, A.; El Moudnib, L.; Mimoun, H.; Villasenor, A.; Gallart, J.; Thomas, C.; Elouai, D.; Mimoun, C.; Himmi, M.

    2013-12-01

    Abstract The results, of a conducted study carried out to analyze variations in ambient seismic noise levels at sites of the installed broadband stations in Morocco, North Africa, are obtained. The permanent and the temporary seismic stations installed in Morocco of the Scientific Institute ( IS, Rabat, Morocco), institute de Ciencias de la Tierra Jaume almera (ICTJA, Barcelona, Spain) and Institut für Geophysik (Munster, Germany) were used in this study. In this work, we used 23 broadband seismic stations installed in different structural domains covering all Morocco from south to north. The main purposes of the current study are: 1) to present a catalog of seismic background noise spectra for Morocco obtained from recently installed broadband stations, 2) to assess the effects of experimental temporary seismic vault construction, 3) to determine the time needed for noise at sites to stabilize, 4) to establish characteristics and origin of seismic noise at those sites. We calculated power spectral densities of background noise for each component of each broadband seismometer deployed in the different investigated sites and then compared them with the high-noise model and low-noise Model of Peterson (1993). All segments from day and night local time windows were included in the calculation without parsing out earthquakes. The obtained results of the current study could be used forthcoming to evaluate permanent station quality. Moreover, this study could be considered as a first step to develop new seismic noise models in North Africa not included in Peterson (1993). Keywords Background noise; Power spectral density; Model of Peterson; Scientific Institute; Institute de Ciencias de la Tierra Jaume almera; Institut für Geophysik

  3. A biological tool to assess flow connectivity in reference temporary streams from the Mediterranean Basin.

    Science.gov (United States)

    Cid, N; Verkaik, I; García-Roger, E M; Rieradevall, M; Bonada, N; Sánchez-Montoya, M M; Gómez, R; Suárez, M L; Vidal-Abarca, M R; Demartini, D; Buffagni, A; Erba, S; Karaouzas, I; Skoulikidis, N; Prat, N

    2016-01-01

    Many streams in the Mediterranean Basin have temporary flow regimes. While timing for seasonal drought is predictable, they undergo strong inter-annual variability in flow intensity. This high hydrological variability and associated ecological responses challenge the ecological status assessment of temporary streams, particularly when setting reference conditions. This study examined the effects of flow connectivity in aquatic macroinvertebrates from seven reference temporary streams across the Mediterranean Basin where hydrological variability and flow conditions are well studied. We tested for the effect of flow cessation on two streamflow indices and on community composition, and, by performing random forest and classification tree analyses we identified important biological predictors for classifying the aquatic state either as flowing or disconnected pools. Flow cessation was critical for one of the streamflow indices studied and for community composition. Macroinvertebrate families found to be important for classifying the aquatic state were Hydrophilidae, Simuliidae, Hydropsychidae, Planorbiidae, Heptageniidae and Gerridae. For biological traits, trait categories associated to feeding habits, food, locomotion and substrate relation were the most important and provided more accurate predictions compared to taxonomy. A combination of selected metrics and associated thresholds based on the most important biological predictors (i.e. Bio-AS Tool) were proposed in order to assess the aquatic state in reference temporary streams, especially in the absence of hydrological data. Although further development is needed, the tool can be of particular interest for monitoring, restoration, and conservation purposes, representing an important step towards an adequate management of temporary rivers not only in the Mediterranean Basin but also in other regions vulnerable to the effects of climate change. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Permanent Temporariness? Changes in Social Contracts in Knowledge Work

    Directory of Open Access Journals (Sweden)

    Bente Rasmussen

    2012-02-01

    Full Text Available Many sociologists have argued that work no longer plays the central role in contemporary life experience because we have entered an age of insecurity in relation to employment, and knowledge workers are often pictured as egoistical portfolio workers who are only interested in their careers and no longer loyal to their employers. Cappelli (1999 on the other hand argues that more insecure employment relations is a result of employers’ strategy to buy workers rather than offering them long-term relations. Using case studies from seven different knowledge work contexts in Norway, this article argues that more temporary employment relations is not the result of career-seeking portfolio workers, but of changes in employment practices of their employers. These are not primarily changes in the formal employment contracts from permanent to temporary employment, but in the social contracts as they are practiced by the employers and experienced by the knowledge workers in the different contexts of knowledge work. The reason for more temporary relations was not because work does not matter for knowledge workers. On the contrary, we found that they accepted insecure conditions because work mattered and because they were eager to take on new tasks, learn the trade in new fields, and show that they were able to do the job. When they left their employer, it was because they were not able to do a good job in their positions or because they were increasingly directly exposed to an insecure market that signaled that they were not profitable (enough for their employer. Although changes in employment practices by the employers toward more short-term relations are not caused by disloyal portfolio workers, these practices may produce the problem of disloyal workers who have to secure their employment in the labor market.

  5. TO ALL MEMBERS OF THE PERSONNEL Temporary work for children of members of the personnel

    CERN Multimedia

    2001-01-01

    During the period mid-June to mid-September 2001, there will be a limited number of vacancies for temporary work at CERN (normally unskilled work of a routine nature) which will be made available to children of members of the personnel (that is, anyone holding an employment or association contract with CERN). It should be noted that candidates must be aged between 18 and 24 inclusive on the first day of the contract, and that they must have insurance cover for both illness and accident. In view of the limited number of vacancies available, no children previously appointed at CERN under this scheme can be considered. The duration of all appointments will be 4 weeks, the allowance being CHF 1538.- net for this period. Application forms can be obtained via the Web at the following address: http://cern.web.cern.ch/CERN/Divisions/PE/ under the heading 'Other Useful Links' or from Paula Barriere, Personnel Management Group (by using the slip below or by electronic mail to Paula.Barriere@.cern.ch). Completed applic...

  6. 76 FR 7898 - Wheego Electric Cars, Inc.; Grant of Application for Temporary Exemption From Advanced Air Bag...

    Science.gov (United States)

    2011-02-11

    ...-0118] Wheego Electric Cars, Inc.; Grant of Application for Temporary Exemption From Advanced Air Bag... grants the petition of Wheego Electric Cars, Inc. (Wheego) for the temporary exemption of its Whip LiFe... manufacturer of a plug-in electric car. The stated basis of the petition was that requiring compliance would...

  7. 76 FR 35909 - Temporary Concession Contract for Blue Ridge Parkway

    Science.gov (United States)

    2011-06-20

    ... accommodations, food and beverage, retail sales, boat rentals, and other services at Crabtree Falls, Price Lake... DEPARTMENT OF THE INTERIOR National Park Service [NPS-WASO-CONC-0511-7182; 2410-OYC] Temporary Concession Contract for Blue Ridge Parkway AGENCY: National Park Service, Interior. ACTION: Notice of...

  8. 8 CFR 244.5 - Temporary treatment benefits for eligible aliens.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Temporary treatment benefits for eligible aliens. 244.5 Section 244.5 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION... for eligible aliens. (a) Prior to the registration period. Prior to the registration period...

  9. Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.

    Science.gov (United States)

    Stepan, L L; Levi, D S; Gans, E; Mohanchandra, K P; Ujihara, M; Carman, G P

    2007-09-01

    Thin film nitinol and single crystal Ni-Mn-Ga represent two new shape memory materials with potential to be used as percutaneously placed implant devices. However, the biocompatibility of these materials has not been adequately assessed. Immersion tests were conducted on both thin film nitinol and single crystal Ni-Mn-Ga in Hank's balanced salt solution at 37 degrees C and pH 7.4. After 12 h, large pits were found on the Ni-Mn-Ga samples while thin film nitinol displayed no signs of corrosion. Further electrochemical tests on thin film nitinol samples revealed breakdown potentials superior to a mechanically polished nitinol disc. These results suggest that passivation or electropolishing of thin film nitinol maybe unnecessary to promote corrosion resistance.

  10. Study on effect of tool electrodes on surface finish during electrical discharge machining of Nitinol

    Science.gov (United States)

    Sahu, Anshuman Kumar; Chatterjee, Suman; Nayak, Praveen Kumar; Sankar Mahapatra, Siba

    2018-03-01

    Electrical discharge machining (EDM) is a non-traditional machining process which is widely used in machining of difficult-to-machine materials. EDM process can produce complex and intrinsic shaped component made of difficult-to-machine materials, largely applied in aerospace, biomedical, die and mold making industries. To meet the required applications, the EDMed components need to possess high accuracy and excellent surface finish. In this work, EDM process is performed using Nitinol as work piece material and AlSiMg prepared by selective laser sintering (SLS) as tool electrode along with conventional copper and graphite electrodes. The SLS is a rapid prototyping (RP) method to produce complex metallic parts by additive manufacturing (AM) process. Experiments have been carried out varying different process parameters like open circuit voltage (V), discharge current (Ip), duty cycle (τ), pulse-on-time (Ton) and tool material. The surface roughness parameter like average roughness (Ra), maximum height of the profile (Rt) and average height of the profile (Rz) are measured using surface roughness measuring instrument (Talysurf). To reduce the number of experiments, design of experiment (DOE) approach like Taguchi’s L27 orthogonal array has been chosen. The surface properties of the EDM specimen are optimized by desirability function approach and the best parametric setting is reported for the EDM process. Type of tool happens to be the most significant parameter followed by interaction of tool type and duty cycle, duty cycle, discharge current and voltage. Better surface finish of EDMed specimen can be obtained with low value of voltage (V), discharge current (Ip), duty cycle (τ) and pulse on time (Ton) along with the use of AlSiMg RP electrode.

  11. Transcatheter closure of ventricular septal defects with nitinol wire occluders of type patent ductus arteriosus.

    Science.gov (United States)

    Wierzyk, Arkadiusz; Szkutnik, Małgorzata; Fiszer, Roland; Banaszak, Paweł; Pawlak, Szymon; Białkowski, Jacek

    2014-01-01

    Ventricular septal defects closure (VSD) depending on the anatomy and clinical setting can be performed surgically or by a hybrid and transcatheter approach. Two cases of children with VSD will be presented. Patients' defects were closed with various types of occluders made of nitinol wire mesh occluder, patent ductus arteriosus (PDA) type. The first case was a 2.5-year-old boy after cardiosurgical correction of tetralogy of Fallot (TOF). After the procedure, a significant haemodynamic residual VSD was observed, which was not successfully closed during the subsequent reoperation. Despite pharmacological treatment, symptoms of heart failure were observed in this patient. In echocardiographic images the residual VSD was presented as a tunnel-like dissection of the ventricular septum (length 6 mm and diameter 3.4 mm). The defect was closed via arterial access with an Amplatzer Duct Occluder II (ADO II). The procedure was successfully performed without any medical complications. In this child, a significant shunt reduction and a noticeable improvement in the patient's clinical status and diminished symptoms of heart failure were noticed. The second patient was a 4-year-old girl suffering from a multi-perforated perimembranous VSD accompanied by a ventricular septal defect with aneurysm. The defect was closed by a venous approach with a PDA Cardio-O-Fix occluder (very similar to ADO I). No short-term or long-term complications were visible during or after the procedure. Only a mild residual shunt through the VSD was observed 6 months afterwards. Transcatheter VSD closure with a proper morphology, with occluders of type Amplatzer Duct Occluder ADO I or ADO II, constitutes a safe and effective therapeutic alternative.

  12. Temporary Rectal Stenting for Management of Severe Perineal Wounds in Two Dogs.

    Science.gov (United States)

    Skinner, Owen T; Cuddy, Laura C; Coisman, James G; Covey, Jennifer L; Ellison, Gary W

    Perineal wounds in dogs present a challenge due to limited local availability of skin for closure and constant exposure to fecal contaminants. This report describes temporary rectal stenting in two dogs following severe perineal wounds. Dog 1 presented with a 4 × 4 cm full-thickness perineal slough secondary to multiple rectal perforations. A 12 mm internal diameter endotracheal tube was placed per-rectum as a temporary stent to minimize fecal contamination. The stent was removed 18 days after placement, and the perineal wound had healed at 32 days post-stent placement, when a minor rectal stricture associated with mild, intermittent tenesmus was detected. Long-term outcome was deemed good. Dog 2 presented with multiple necrotic wounds with myiasis, circumferentially surrounding the anus and extending along the tail. A 14 mm internal diameter endotracheal tube was placed per-rectum. The perineal and tail wounds were managed with surgical debridement and wet-to-dry and honey dressings prior to caudectomy and negative pressure wound therapy (NPWT). Delayed secondary wound closure and stent removal were performed on day six without complication. Long-term outcome was deemed excellent. Temporary rectal stenting may be a useful technique for fecal diversion to facilitate resolution of complex perineal injuries, including rectal perforation.

  13. Orange Houses and Tape Babies Temporary and Nebulous Art in Urban Spaces

    Directory of Open Access Journals (Sweden)

    Carmen L. McClish

    2010-12-01

    Full Text Available This essay argues that the disruption of the routine ways we engage with our cities is necessary for democratic activity and public participation. Building on research that examines the relationship between public spaces and democratic action, I explore temporary forms of creative street installation as interrupting the market-ing pleas that have become the only authorized forms of visual art in our cities. I argue that tactics in urban spaces that are temporary and provide nebulous mean-ings are necessary to grab our attention and make us linger. I propose that these forms of engagement act in the same way as people performing or playing in pub-lic spaces. I specifically employ Yi-Fu Tuan’s theoretical notions of space and movement and Margaret Kohn’s discussion of the significance of presence in pub-lic spaces to examine the creative ways we engage with and experience our cities. I examine two activist/artist projects: Mark Jenkins’ tape installations and Detroit Demolition. My analysis of these two sites demonstrates the importance of citi-zens engaging in their urban spaces. By creating temporary artwork that is nebul-ous in meaning, activists/artists are interrupting the routine ways we experience our cities.

  14. Evaluation of temporary non-code repairs in safety class 3 piping systems

    International Nuclear Information System (INIS)

    Godha, P.C.; Kupinski, M.; Azevedo, N.F.

    1996-01-01

    Temporary non-ASME Code repairs in safety class 3 pipe and piping components are permissible during plant operation in accordance with Nuclear Regulatory Commission Generic Letter 90-05. However, regulatory acceptance of such repairs requires the licensee to undertake several timely actions. Consistent with the requirements of GL 90-05, this paper presents an overview of the detailed evaluation and relief request process. The technical criteria encompasses both ductile and brittle piping materials. It also lists appropriate evaluation methods that a utility engineer can select to perform a structural integrity assessment for design basis loading conditions to support the use of temporary non-Code repair for degraded piping components. Most use of temporary non-code repairs at a nuclear generating station is in the service water system which is an essential safety related system providing the ultimate heat sink for various plant systems. Depending on the plant siting, the service water system may use fresh water or salt water as the cooling medium. Various degradation mechanisms including general corrosion, erosion/corrosion, pitting, microbiological corrosion, galvanic corrosion, under-deposit corrosion or a combination thereof continually challenge the pressure boundary structural integrity. A good source for description of corrosion degradation in cooling water systems is provided in a cited reference

  15. The influence of premature loss of temporary upper molars on permanent molars.

    Science.gov (United States)

    Cernei, E R; Maxim, Dana Cristiana; Zetu, Irina Nicoleta

    2015-01-01

    Premature loss of primary molars due to dental caries and their complications has been associated with space loss and eruptive difficulties, especially when the loss occurs early. The aim of our study was to determine the impact of premature loss of temporary upper molars upon the longitudinal axis of the first and second upper permanent molar. The study group included 64 patients 6-9 years old with premature loss of primary molars and a control group of 48 patients with intact temporary teeth. It was evaluated the angle between longitudinal axis of first and second upper permanent molars and occlusal plane. The sofware used is Easy Dent 4 Viewer®.The data were analyzed by using the Statistical Package for the Social Sciences (version 20.0; SPSS, Chicago, III). It was observed that premature loss of upper second deciduous molars modifies greater the vertical axis of the permanent molars than the premature loss of first upper primary molar. First upper primary molar loss cause an acceleration eruption of first premolar, which will produce a distal inclintion of the both permanent molars. The use of space maintainers after premature loss of the second upper temporary molar is a last solution in preventing tridimensional lesions in the dental arch and occlusion.

  16. Ecotoxicology of organisms adapted to life in temporary freshwater ponds in arid and semi-arid regions.

    Science.gov (United States)

    Lahr, J

    1997-01-01

    Hot arid and semi-arid zones are characterized by an abundance of temporary ponds. Most of these depend on rain for their existence. These habitats are distinguished by fluctuating and unpredictable changes in their hydrological regime and of physical and chemical conditions.They contain a uniquely-adapted fauna that copes in different ways with changing and often extreme temperatures, oxygen levels, pH, salinity and turbidity. A classification is presented of the most distinctive adaptations,the various tactics that organisms apply to survive dry periods. The main strategies are dormancy (escape in time) and dispersal (escape in space). These adaptations may affect the impact of toxicants on individuals, populations and communities of temporary ponds. The physiological adaptations of species found in temporary ponds are likely to alter the sensitivity to pollutants of characteristic species. Results from laboratory experiments,for example, suggest that fairy shrimp (Branchiopoda, Anostraca) may react differently to heavy metals and pesticides as the standard test species Daphnia. Life history strategies influence recovery rates of populations after exposure to acutely toxic substances such as pesticides. It is also suggested that slow growth and decreased reproductive capacity of organisms caused by toxicants may, in ephemeral ponds, result in the failure of annual recruitment. Whether assemblages of organisms in temporary ponds are generally more vulnerable or more resilient than those in permanent waters or temperate regions could not be determined conclusively with the limited data available. Ecological concepts for studying the habitat and the development of risk assessment methods for temporary ponds are briefly discussed.

  17. Influence of Temporary Cements on the Bond Strength of Self-Adhesive Cement to the Metal Coronal Substrate.

    Science.gov (United States)

    Peixoto, Raniel Fernandes; De Aguiar, Caio Rocha; Jacob, Eduardo Santana; Macedo, Ana Paula; De Mattos, Maria da Gloria Chiarello; Antunes, Rossana Pereira de Almeida

    2015-01-01

    This research evaluated the influence of temporary cements (eugenol-containing [EC] or eugenol-free [EF]) on the tensile strength of Ni-Cr copings fixed with self-adhesive resin cement to the metal coronal substrate. Thirty-six temporary crowns were divided into 4 groups (n=9) according to the temporary cements: Provy, Dentsply (eugenol-containing), Temp Cem, Vigodent (eugenol-containing), RelyX Temp NE, 3M ESPE (eugenol-free) and Temp Bond NE, Kerr Corp (eugenol-free). After 24 h of temporary cementation, tensile strength tests were performed in a universal testing machine at a crosshead speed of 0.5 mm/min and 1 kN (100 kgf) load cell. Afterwards, the cast metal cores were cleaned by scraping with curettes and air jet. Thirty-six Ni-Cr copings were cemented to the cast metal cores with self-adhesive resin cement (RelyX U200, 3M ESPE). Tensile strength tests were performed again. In the temporary cementation, Temp Bond NE (12.91 ± 2.54) and Temp Cem (12.22 ± 2.96) presented the highest values of tensile strength and were statistically similar to each other (p>0.05). Statistically significant difference (pcementation of Ni-Cr copings with self-adhesive resin cement. In addition, Temp Cem (120.68 ± 48.27) and RelyX Temp NE (103.04 ± 26.09) showed intermediate tensile strength values. In conclusion, the Provy eugenol-containing temporary cement was associated with the highest bond strength among the resin cements when Ni-Cr copings were cemented to cast metal cores. However, the eugenol cannot be considered a determining factor in increased bond strength, since the other tested cements (1 eugenol-containing and 2 eugenol-free) were similar.

  18. The influence of temporary differences between accounting and tax revenues, proprietary costs and liquidity on profit growth

    Directory of Open Access Journals (Sweden)

    NURAMALIA HASANAH

    2017-07-01

    Full Text Available This study aimed to examine the influence of temporary differences between accounting profit and tax, proprietary costs, and Liquidity toward earnings growth of the companies listed in Indonesia Stock Exchange (IDX 2011-2012. The factors examined in this study are temporary differences between accounting profit and tax, proprietary costs, and liquidity as an independent variable, while earnings growth has the dependent variable. This study used a descriptive quantitative method using secondary data and the number of samples collected was thirty- eight (38 that have met the criteria the researchers used purposive sampling. From the data that has been collected and then processed and analyzed using multiple regression analysis with a significance level of 0.05. This research proves temporary differences between accounting profit and tax has no significant influence on earnings growth, proprietary cost has no significant influence on earnings growth, and liquidity has negatively significant influence earnings growth. Temporary differences between accounting profit and tax, proprietary costs, and liquidity together or simultaneously significant influence toward the earnings growth.

  19. Instruction manual for operating the Sensys System for temporary traffic counts

    Science.gov (United States)

    2010-01-01

    This instruction manual provides information and the procedures for using the Sensys System, which was initially designed to operate in a server controlled network, for temporary traffic counts. The instructions will allow the user to fully understan...

  20. Tolerance of herbaceous summer legumes of temporary waterlogging

    Directory of Open Access Journals (Sweden)

    Elsa M. Ciotti

    2014-09-01

    Full Text Available A greenhouse study to evaluate adaptation of 4 herbaceous summer legumes to temporary waterlogging was conducted.  Species evaluated were Desmanthus virgatus and Aeschynomene americana in their vegetative stage, and Macroptilium lathyroides and M. atropurpureum in both vegetative and reproductive stages.  The experimental design was randomized blocks with 5 replications and treatments were:  T0, control; T1, saturation by capillary movement placing pots in buckets of 5 L with 10 cm of permanent water; and T2, flooding, placing pots in buckets of 10 L and a layer of water 5 cm above the soil.  The duration of the water treatments was 7 days. Waterlogging did not affect shoot or root biomass production nor nodulation in A. americana, whereas D. virgatus had its highest dry matter production in saturated soil (T1.  In M. lathyroides flooding tolerance was more evident in the reproductive than in the vegetative stage, probably due to more production of adventitious roots and formation of aerenchymatic tissue.  Macroptilium atropurpureum showed adaptation to temporary flooding.  Survival and quick recovery of these species would confirm their potential as forages for temporarily waterlogged soils.Keywords: Forage legumes, flooding, Aeschynomene americana, Desmanthus virgatus, Macroptilium lathyroides, Northeast Argentina.DOI: 10.17138/TGFT(2278-286