WorldWideScience

Sample records for techniques fetale harntraktveraenderungen

  1. Fetal magnetic resonance: technique applications and normal fetal anatomy

    International Nuclear Information System (INIS)

    Martin, C.; Darnell, A.; Duran, C.; Mellado, F.; Corona, M

    2003-01-01

    Ultrasonography is the preferred diagnostic imaging technique for intrauterine fetal examination. Nevertheless, circumstances sometimes dictate the use of other techniques in order to analyze fetal structures. The advent of ultra rapid magnetic resonance (MR) sequencing has led to the possibility of doing MR fetal studies, since images are obtained in an extradordiarily short time and are not affected by either maternal or fetal movements. It does not employ ionizing radiations, it provides high-contrast images and it can obtain such images in any plane of space without being influenced by either the child bearer's physical characteristics of fetal position. MR provides good quality images of most fetal organs. It is extremely useful in analysing distinct structures, as well as permitting an evaluation of cervical structures, lungs, diaphragms, intra-abdominal and retroperitoneal structures, and fetal extremities. It can also provide useful information regarding the placenta,umbilical cord, amniotic fluid and uterus. The objective of this work is to describe MR technique as applied to intrauterine fetal examination, and to illustrate normal fetal anatomy as manifested by MR and its applications. (Author) 42 refs

  2. Fetal genitourinary anomalies. Perinatal and postnatal management with imaging techniques; Fetale Harntraktveraenderungen. Peri- und postnatales bildgebendes Management

    Energy Technology Data Exchange (ETDEWEB)

    Gassner, I. [Universitaetsklinik fuer Kinder- und Jugendheilkunde, Abteilung Kinderradiologie, Innsbruck (Austria)

    2005-12-01

    Improvements in ultrasound technology and the appropriate timing of antenatal ultrasound has led to refined prenatal diagnosis and enhanced accuracy of diagnosis of fetal renal anomalies and makes it possible to treat obstructive and/or refluxing uropathies before the onset of clinical symptoms. The third trimester renal sonography is the most important to detect hydronephrosis amenable to treatment. Classically, the prenatal diagnosis of hydronephrosis, unilateral renal agenesis, or MDKD initiates postnatal investigations, including sonography, voiding cystourethrography (VCUG), and isotopic renography. The exact degree of renal pelvic dilatation that requires full postnatal investigation is still not entirely resolved. Most authors accept the upper limit of 7 mm for the AP diameter of the renal pelvis. The US examination should be performed after the physiological dehydration period, namely 3-5 days after birth, in an urgent case on the 1st day. A meticulous ultrasound examination performed by a physician who is familiar with the renal abnormalities shows the whole extent of underlying pathology. The role of MR urography in the work-up of renal anomalies, particularly of hydronephrosis, is currently being investigated. Due to the close developmental relationship of the urinary and genital tracts, malformations frequently occur in both of these systems. Therefore in all patients, especially in girls with renal anomalies (unilateral renal agenesis, multicystic dysplastic kidney disease), the internal genitalia need to be evaluated. (orig.) [German] Die praenatale Ultraschalluntersuchung, v. a. im 3. Trimenon, erfasst viele Harntraktanomalien, die einer Behandlung zugaenglich sind, bevor sie klinisch durch eine Harnweginfektion oder Niereninsuffizienz symptomatisch werden. Sie lenkt die gezielte postnatale Bildgebung, mit der beim Neugeborenen die praenatal entdeckte Pathologie abgeklaert wird. Die Ultraschalluntersuchung durch einen mit dem Spektrum moeglicher

  3. Indications and technique of fetal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Asenbaum, U.; Woitek, R.; Furtner, J.; Prayer, D.; Brugger, P.C.

    2013-01-01

    Evaluation and confirmation of fetal pathologies previously suspected or diagnosed with ultrasound. Ultrasound and magnetic resonance imaging (MRI). Technique for prenatal fetal examination. Fetal MRI is an established supplementary technique to prenatal ultrasound. Fetal MRI should only be used as an additional method in prenatal diagnostics and not for routine screening. Fetal MRI should only be performed in perinatal medicine centers after a previous level III ultrasound examination. (orig.) [de

  4. Fetal magnetic resonance imaging: methods and techniques; Fetale Magnetresonanztomographie: Methoden und Technik

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, P.C. [Zentrum fuer Anatomie und Zellbiologie, Medizinische Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie; Stuhr, F.; Lindner, C.; Prayer, D. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik

    2006-02-15

    Since the introduction of fetal magnetic resonance imaging (MRI) into prenatal diagnostics, advances in coil technology and development of ultrafast sequences have further enhanced this technique. At present numerous sequences are available to visualize the whole fetus with high resolution and image quality, even in late stages of pregnancy. Taking into consideration the special circumstances of examination and adjusting sequence parameters to gestational age, fetal anatomy can be accurately depicted. The variety of sequences also allows further characterization of fetal tissues and pathologies. Fetal MRI not only supplies additional information to routine ultrasound studies, but also reveals fetal morphology and pathology in a way hitherto not possible. (orig.) [German] Seit Einfuehrung der fetalen Magnetresonanztomographie (MRT) in die praenatale Diagnostik wurde das Verfahren durch neue Spulentechniken und die Entwicklung ultraschneller Sequenzen kontinuierlich weiter entwickelt. Gegenwaertig steht eine Vielzahl von Sequenzen zur Verfuegung, die es erlauben, mit hoher Bildqualitaet und raeumlicher Aufloesung selbst in fortgeschrittenen Schwangerschaftsstadien den gesamten Feten darzustellen. Unter Beruecksichtigung der speziellen Untersuchungsbedingungen und des Schwangerschaftsalters kann so die fetale Anatomie genau abgebildet werden. Die Vielfalt an Sequenzen und deren gezielter Einsatz ermoeglichen es weiter, fetale Gewebe und Pathologien naeher zu charakterisierten. Auf diese Weise liefert die fetale MRT nicht nur Zusatzinformationen zur Routineultraschalluntersuchung, sie gibt auch Aufschluss ueber bestimmte fetale Morphologien und Pathologien, die bisher nicht darstellbar waren. (orig.)

  5. Fetal Cardiac Doppler Signal Processing Techniques: Challenges and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Saeed Abdulrahman Alnuaimi

    2017-12-01

    Full Text Available The fetal Doppler Ultrasound (DUS is commonly used for monitoring fetal heart rate and can also be used for identifying the event timings of fetal cardiac valve motions. In early-stage fetuses, the detected Doppler signal suffers from noise and signal loss due to the fetal movements and changing fetal location during the measurement procedure. The fetal cardiac intervals, which can be estimated by measuring the fetal cardiac event timings, are the most important markers of fetal development and well-being. To advance DUS-based fetal monitoring methods, several powerful and well-advanced signal processing and machine learning methods have recently been developed. This review provides an overview of the existing techniques used in fetal cardiac activity monitoring and a comprehensive survey on fetal cardiac Doppler signal processing frameworks. The review is structured with a focus on their shortcomings and advantages, which helps in understanding fetal Doppler cardiogram signal processing methods and the related Doppler signal analysis procedures by providing valuable clinical information. Finally, a set of recommendations are suggested for future research directions and the use of fetal cardiac Doppler signal analysis, processing, and modeling to address the underlying challenges.

  6. Indications and technique of fetal magnetic resonance imaging; Indikationen und Technik der fetalen Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, U.; Woitek, R.; Furtner, J.; Prayer, D. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Brugger, P.C. [Medizinische Universitaet Wien, Zentrum fuer Anatomie und Zellbiologie, Wien (Austria)

    2013-02-15

    Evaluation and confirmation of fetal pathologies previously suspected or diagnosed with ultrasound. Ultrasound and magnetic resonance imaging (MRI). Technique for prenatal fetal examination. Fetal MRI is an established supplementary technique to prenatal ultrasound. Fetal MRI should only be used as an additional method in prenatal diagnostics and not for routine screening. Fetal MRI should only be performed in perinatal medicine centers after a previous level III ultrasound examination. (orig.) [German] Evaluierung und Bestaetigung von im praenatalen Ultraschall entdeckten Pathologien. Ultraschall und Magnetresonanztomographie. Praenatale Untersuchungsmethode. Die fetale MRT ist inzwischen als ergaenzende Methode zum praenatalen Ultraschall anerkannt. Die fetale MRT soll als additive Methode bei klinischer Relevanz, nicht jedoch als Routinescreeningverfahren waehrend der Schwangerschaft angewendet werden. Durchfuehrung ausschliesslich an einem Perinatalzentrum nach vorangegangenem Level-III-Ultraschall. (orig.)

  7. Fetal MRI: techniques and protocols

    International Nuclear Information System (INIS)

    Prayer, Daniela; Brugger, Peter Christian; Prayer, Lucas

    2004-01-01

    The development of ultrafast sequences has led to a significant improvement in fetal MRI. Imaging protocols have to be adjusted to the rapidly developing fetal central nervous system (CNS) and to the clinical question. Sequence parameters must be changed to cope with the respective developmental stage, to produce images free from motion artefacts and to provide optimum visualization of the region and focus of interest. In contrast to postnatal studies, every suspect fetal CNS abnormality requires examination of the whole fetus and the extrafetal intrauterine structures including the uterus. This approach covers both aspects of fetal CNS disorders: isolated and complex malformations and cerebral lesions arising from the impaired integrity of the feto-placental unit. (orig.)

  8. Fetal MRI: techniques and protocols

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Neuroradiology, University Clinics of Radiodiagnostics, Medical University Vienna, Waehringerguertel 18-10, 1090, Vienna (Austria); Brugger, Peter Christian [Department of Anatomy, Integrative Morphology Group, Medical University Vienna (Austria); Prayer, Lucas [Diagnosezentrum Urania, Vienna (Austria)

    2004-09-01

    The development of ultrafast sequences has led to a significant improvement in fetal MRI. Imaging protocols have to be adjusted to the rapidly developing fetal central nervous system (CNS) and to the clinical question. Sequence parameters must be changed to cope with the respective developmental stage, to produce images free from motion artefacts and to provide optimum visualization of the region and focus of interest. In contrast to postnatal studies, every suspect fetal CNS abnormality requires examination of the whole fetus and the extrafetal intrauterine structures including the uterus. This approach covers both aspects of fetal CNS disorders: isolated and complex malformations and cerebral lesions arising from the impaired integrity of the feto-placental unit. (orig.)

  9. Enhancement of Twins Fetal ECG Signal Extraction Based on Hybrid Blind Extraction Techniques

    Directory of Open Access Journals (Sweden)

    Ahmed Kareem Abdullah

    2017-07-01

    Full Text Available ECG machines are noninvasive system used to measure the heartbeat signal. It’s very important to monitor the fetus ECG signals during pregnancy to check the heat activity and to detect any problem early before born, therefore the monitoring of ECG signals have clinical significance and importance. For multi-fetal pregnancy case the classical filtering algorithms are not sufficient to separate the ECG signals between mother and fetal. In this paper the mixture consists of mixing from three ECG signals, the first signal is the mother ECG (M-ECG signal, second signal the Fetal-1 ECG (F1-ECG, and third signal is the Fetal-2 ECG (F2-ECG, these signals are extracted based on modified blind source extraction (BSE techniques. The proposed work based on hybridization between two BSE techniques to ensure that the extracted signals separated well. The results demonstrate that the proposed work very efficiently to extract the useful ECG signals

  10. Additive Manufacturing Techniques for the Reconstruction of 3D Fetal Faces

    Directory of Open Access Journals (Sweden)

    Domenico Speranza

    2017-01-01

    Full Text Available This paper deals with additive manufacturing techniques for the creation of 3D fetal face models starting from routine 3D ultrasound data. In particular, two distinct themes are addressed. First, a method for processing and building 3D models based on the use of medical image processing techniques is proposed. Second, the preliminary results of a questionnaire distributed to future parents consider the use of these reconstructions both from an emotional and an affective point of view. In particular, the study focuses on the enhancement of the perception of maternity or paternity and the improvement in the relationship between parents and physicians in case of fetal malformations, in particular facial or cleft lip diseases.

  11. Fast, free-breathing, in vivo fetal imaging using time-resolved 3D MRI technique: preliminary results.

    Science.gov (United States)

    Liu, Jing; Glenn, Orit A; Xu, Duan

    2014-04-01

    Fetal MR imaging is very challenging due to the movement of fetus and the breathing motion of the mother. Current clinical protocols involve quick 2D scouting scans to determine scan plane and often several attempts to reorient the scan plane when the fetus moves. This makes acquisition of fetal MR images clinically challenging and results in long scan times in order to obtain images that are of diagnostic quality. Compared to 2D imaging, 3D imaging of the fetus has many advantages such as higher SNR and ability to reformat images in multiple planes. However, it is more sensitive to motion and challenging for fetal imaging due to irregular fetal motion in addition to maternal breathing and cardiac motion. This aim of this study is to develop a fast 3D fetal imaging technique to resolve the challenge of imaging the moving fetus. This 3D imaging sequence has multi-echo radial sampling in-plane and conventional Cartesian encoding through plane, which provides motion robustness and high data acquisition efficiency. The utilization of a golden-ratio based projection profile allows flexible time-resolved image reconstruction with arbitrary temporal resolution at arbitrary time points as well as high signal-to-noise and contrast-to-noise ratio. The nice features of the developed image technique allow the 3D visualization of the movements occurring throughout the scan. In this study, we applied this technique to three human subjects for fetal MRI and achieved promising preliminary results of fetal brain, heart and lung imaging.

  12. Advanced MRI techniques of the fetal brain

    International Nuclear Information System (INIS)

    Schoepf, V.; Dittrich, E.; Berger-Kulemann, V.; Kasprian, G.; Kollndorfer, K.; Prayer, D.

    2013-01-01

    Evaluation of the normal and pathological fetal brain. Magnetic resonance imaging (MRI). Advanced MRI of the fetal brain. Diffusion tensor imaging (DTI) is used in clinical practice, all other methods are used at a research level. Serving as standard methods in the future. Combined structural and functional data for all gestational ages will allow more specific insight into the developmental processes of the fetal brain. This gain of information will help provide a common understanding of complex spatial and temporal procedures of early morphological features and their impact on cognitive and sensory abilities. (orig.) [de

  13. Non-invasive pulsed cavitational ultrasound for fetal tissue ablation: feasibility study in a fetal sheep model.

    Science.gov (United States)

    Kim, Y; Gelehrter, S K; Fifer, C G; Lu, J C; Owens, G E; Berman, D R; Williams, J; Wilkinson, J E; Ives, K A; Xu, Z

    2011-04-01

    Currently available fetal intervention techniques rely on invasive procedures that carry inherent risks. A non-invasive technique for fetal intervention could potentially reduce the risk of fetal and obstetric complications. Pulsed cavitational ultrasound therapy (histotripsy) is an ablation technique that mechanically fractionates tissue at the focal region using extracorporeal ultrasound. In this study, we investigated the feasibility of using histotripsy as a non-invasive approach to fetal intervention in a sheep model. The experiments involved 11 gravid sheep at 102-129 days of gestation. Fetal kidney, liver, lung and heart were exposed to ultrasound pulses (bones. Histological assessment confirmed lesion locations and sizes corresponding to regions where cavitation was monitored, with no lesions found when cavitation was absent. Inability to generate cavitation was primarily associated with increased depth to target and obstructing structures such as fetal limbs. Extracorporeal histotripsy therapy successfully created targeted lesions in fetal sheep organs without significant damage to overlying structures. With further improvements, histotripsy may evolve into a viable technique for non-invasive fetal intervention procedures. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  14. Fetal magnetic resonance imaging: indications, technique, anatomical considerations and a review of fetal abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Ertl-Wagner, Birgit [Department of Radiology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Present address: Institute of Clinical Radiology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Lienemann, Andreas; Reiser, Maximilian F. [Department of Radiology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Strauss, Alexander [Department of Obstetrics and Gynecology, Klinikum Grosshadern, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany)

    2002-08-01

    Fetal MR imaging often poses a diagnostic challenge for the radiologist. Both fetal anatomy and pathology differ decidedly from pediatric and adult MR imaging. While ultrasound remains the method of choice for screening examinations of the fetus, MR imaging is playing an increasingly important role in the detection and classification of malformations not diagnosable by ultrasonography alone. Recently, advances in fast single-shot MR sequences have allowed high-resolution, high-quality imaging of the moving fetus. Preferable sequences to be applied are a true fast imaging steady precession (true-FISP) or a half-Fourier acquired single-shot turbo spin-echo (HASTE) sequence. Premedication is generally no longer required. In all fetal MR imaging, every aspect of fetal anatomy has to be scrutinized. Subsequently, any abnormalities need to be described and classified. A close collaboration with the referring obstetrician is of paramount importance. (orig.)

  15. Fetal anatomy revealed with fast MR sequences.

    Science.gov (United States)

    Levine, D; Hatabu, H; Gaa, J; Atkinson, M W; Edelman, R R

    1996-10-01

    Although all the imaging studies in this pictorial essay were done for maternal rather than fetal indications, fetal anatomy was well visualized. However, when scans are undertaken for fetal indications, fetal motion in between scout views and imaging sequences may make specific image planes difficult to obtain. Of the different techniques described in this review, we preferred the HASTE technique and use it almost exclusively for scanning pregnant patients. The T2-weighting is ideal for delineating fetal organs. Also, the HASTE technique allows images to be obtained in 430 msec, limiting artifacts arising from maternal and fetal motion. MR imaging should play a more important role in evaluating equivocal sonographic cases as fast scanning techniques are more widely used. Obstetric MR imaging no longer will be limited by fetal motion artifacts. When complex anatomy requires definition in a complicated pregnant patient, MR imaging should be considered as a useful adjunct to sonography.

  16. Fetal response to abbreviated relaxation techniques. A randomized controlled study.

    Science.gov (United States)

    Fink, Nadine S; Urech, Corinne; Isabel, Fornaro; Meyer, Andrea; Hoesli, Irène; Bitzer, Johannes; Alder, Judith

    2011-02-01

    stress during pregnancy can have adverse effects on the course of pregnancy and on fetal development. There are few studies investigating the outcome of stress reduction interventions on maternal well-being and obstetric outcome. this study aims (1) to obtain fetal behavioral states (quiet/active sleep, quiet/active wakefulness), (2) to investigate the effects of maternal relaxation on fetal behavior as well as on uterine activity, and (3) to investigate maternal physiological and endocrine parameters as potential underlying mechanisms for maternal-fetal relaxation-transferral. the behavior of 33 fetuses was analyzed during laboratory relaxation/quiet rest (control group, CG) and controlled for baseline fetal behavior. Potential associations between relaxation/quiet rest and fetal behavior (fetal heart rate (FHR), FHR variation, FHR acceleration, and body movements) and uterine activity were studied, using a computerized cardiotocogram (CTG) system. Maternal heart rate, blood pressure, cortisol, and norepinephrine were measured. intervention (progressive muscle relaxation, PMR, and guided imagery, GI) showed changes in fetal behavior. The intervention groups had higher long-term variation during and after relaxation compared to the CG (p=.039). CG fetuses had more FHR acceleration, especially during and after quiet rest (p=.027). Women in the PMR group had significantly more uterine activity than women in the GI group (p=.011) and than CG women. Maternal heart rate, blood pressure, and stress hormones were not associated with fetal behavior. this study indicates that the fetus might participate in maternal relaxation and suggests that GI is superior to PMR. This could especially be true for women who tend to direct their attention to body sensations such as abdominal activity. 2010 Elsevier Ltd. All rights reserved.

  17. Detection and Processing Techniques of FECG Signal for Fetal Monitoring

    Directory of Open Access Journals (Sweden)

    Hasan MA

    2009-03-01

    Full Text Available Abstract Fetal electrocardiogram (FECG signal contains potentially precise information that could assist clinicians in making more appropriate and timely decisions during labor. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies are becoming very important requirements in fetal monitoring. The purpose of this review paper is to illustrate the various methodologies and developed algorithms on FECG signal detection and analysis to provide efficient and effective ways of understanding the FECG signal and its nature for fetal monitoring. A comparative study has been carried out to show the performance and accuracy of various methods of FECG signal analysis for fetal monitoring. Finally, this paper further focused some of the hardware implementations using electrical signals for monitoring the fetal heart rate. This paper opens up a passage for researchers, physicians, and end users to advocate an excellent understanding of FECG signal and its analysis procedures for fetal heart rate monitoring system.

  18. MRI of the fetal abdomen

    International Nuclear Information System (INIS)

    Hoermann, M.; Brugger, P.C.; Witzani, L.; Prayer, D.

    2006-01-01

    Magnetic resonance imaging (MRI) is an important diagnostic component for central nervous system and thoracic diseases during fetal development. Although ultrasound remains the method of choice for observing the fetus during pregnancy, fetal MRI is being increasingly used as an additional technique for the accurate diagnosis of abdominal diseases. Recent publications confirm the value of MRI in the diagnosis of fetal gastrointestinal tract and urogenital system diseases. The following report provides an overview of MRI-examination techniques for the most frequent diseases of the abdomen. (orig.) [de

  19. Fetal MRI: A Technical Update with Educational Aspirations.

    Science.gov (United States)

    Gholipour, Ali; Estroff, Judith A; Barnewolt, Carol E; Robertson, Richard L; Grant, P Ellen; Gagoski, Borjan; Warfield, Simon K; Afacan, Onur; Connolly, Susan A; Neil, Jeffrey J; Wolfberg, Adam; Mulkern, Robert V

    2014-11-01

    Fetal magnetic resonance imaging (MRI) examinations have become well-established procedures at many institutions and can serve as useful adjuncts to ultrasound (US) exams when diagnostic doubts remain after US. Due to fetal motion, however, fetal MRI exams are challenging and require the MR scanner to be used in a somewhat different mode than that employed for more routine clinical studies. Herein we review the techniques most commonly used, and those that are available, for fetal MRI with an emphasis on the physics of the techniques and how to deploy them to improve success rates for fetal MRI exams. By far the most common technique employed is single-shot T2-weighted imaging due to its excellent tissue contrast and relative immunity to fetal motion. Despite the significant challenges involved, however, many of the other techniques commonly employed in conventional neuro- and body MRI such as T1 and T2*-weighted imaging, diffusion and perfusion weighted imaging, as well as spectroscopic methods remain of interest for fetal MR applications. An effort to understand the strengths and limitations of these basic methods within the context of fetal MRI is made in order to optimize their use and facilitate implementation of technical improvements for the further development of fetal MR imaging, both in acquisition and post-processing strategies.

  20. Clinical implications from monitoring fetal activity.

    Science.gov (United States)

    Rayburn, W F

    1982-12-15

    The monitoring of fetal motion in high-risk pregnancies has been shown to be worthwhile in predicting fetal distress and impending fetal death. The maternal recording of perceived fetal activity is an inexpensive surveillance technique which is most useful when there is chronic uteroplacental insufficiency or when a stillbirth may be expected. The presence of an active, vigorous fetus is reassuring, but documented fetal inactivity required a reassessment of the underlying antepartum complication and further fetal evaluation with real-time ultrasonography, fetal heart rate testing, and biochemical testing. Fetal distress from such acute changes as abruptio placentae or umbilical cord compression may not be predicted by monitoring fetal motion. Although not used for routine clinical investigation, electromechanical devices such as tocodynamometry have provided much insight into fetal behavioral patterns at many stages of pregnancy and in pregnancies with an antepartum complication.

  1. Prenatal diagnosis of congenital toxoplasmosis: comparative value of fetal blood and amniotic fluid using serological techniques and cultures.

    Science.gov (United States)

    Fricker-Hidalgo, H; Pelloux, H; Muet, F; Racinet, C; Bost, M; Goullier-Fleuret, A; Ambroise-Thomas, P

    1997-09-01

    The prenatal diagnosis of congenital toxoplasmosis is mainly based on biological tests performed on fetal blood and amniotic fluid. We studied the performance of neonatal diagnosis procedures and the results of fetal blood and amniotic fluid analysis. Of 127 women who contracted toxoplasmosis and underwent prenatal diagnosis, the postnatal serological follow-up was long enough to definitively diagnose congenital toxoplasmosis in 19 cases and to exclude it in 27 cases. Prenatal diagnosis allowed the detection of 94.7 per cent (18/19) of the infected fetuses. The sensitivities of tests in amniotic fluid and fetal blood were equivalent, 88.2 per cent (15/17) and 87.5 per cent (14/16), respectively. In fetal blood, biological techniques were positive in 12/16 cases and in 2/16 cases, serological tests were the only positive sign. The specificities of tests in amniotic fluid and fetal blood were respectively 100 per cent (23/23) and 86.3 per cent (19/22) (three false-positive serological results). These results, added to the lower morbidity of amniocentesis compared with cordocentesis, might lead to cordocentesis being abandoned in the prenatal diagnosis of congenital toxoplasmosis.

  2. Fetal cardiology

    International Nuclear Information System (INIS)

    Meijboom, E.J.; Rijsterborgh, N.; Bom, N.

    1986-01-01

    Doppler echocardiography makes it possible to diagnose congenital heart disease in early pregnancy. It allows us to study the anatomical configuration of the fetal heart, and additionally, to evaluate the physiological conditions of the fetus. Evaluation of the direction, velocity, wave form pattern, and quantification of blood flow at the various sites in the fetal heart helps us to assess the characteristics of the fetal circulation and condition of the fetal heart. In order to use this technique in pathological situations, an initial study of the developing normal human fetal circulation was necessary. The authors studied 34 uncomplicated pregnancies by serial Doppler echocardiography. The studies were performed every 4 weeks from 16-weeks gestation to term. The pulsed Doppler sector scanner provided cardiac cross-sectional images, mitral and tricuspid blood velocities were obtained from apical four-chamber views. Angle corrected maximal and mean temporal velocities were calculated by digitizing the Doppler frequency shift recording on a graphic tablet computed with a minicomputer. The angle between the Doppler interrogation beam and the direction of blood flow was kept as small as possible in order to minimize the error

  3. Investigation of conformal and intensity-modulated radiation therapy techniques to determine the absorbed fetal dose in pregnant patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Öğretici, Akın, E-mail: akinogretici@gmail.com; Akbaş, Uğur; Köksal, Canan; Bilge, Hatice

    2016-07-01

    The aim of this research was to investigate the fetal doses of pregnant patients undergoing conformal radiotherapy or intensity-modulated radiation therapy (IMRT) for breast cancers. An Alderson Rando phantom was chosen to simulate a pregnant patient with breast cancer who is receiving radiation therapy. This phantom was irradiated using the Varian Clinac DBX 600 system (Varian Medical System, Palo Alto, CA) linear accelerator, according to the standard treatment plans of both three-dimensional conformal radiation therapy (3-D CRT) and IMRT techniques. Thermoluminescent dosimeters were used to measure the irradiated phantom's virtually designated uterus area. Thermoluminescent dosimeter measurements (in the phantom) revealed that the mean cumulative fetal dose for 3-D CRT is 1.39 cGy and for IMRT it is 8.48 cGy, for a pregnant breast cancer woman who received radiation treatment of 50 Gy. The fetal dose was confirmed to increase by 70% for 3-D CRT and 40% for IMRT, if it is closer to the irradiated field by 5 cm. The mean fetal dose from 3-D CRT is 1.39 cGy and IMRT is 8.48 cGy, consistent with theoretic calculations. The IMRT technique causes the fetal dose to be 5 times more than that of 3-D CRT. Theoretic knowledge concerning the increase in the peripheral doses as the measurements approached the beam was also practically proven.

  4. The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block.

    Science.gov (United States)

    Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando

    2017-01-01

    Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.

  5. Fetal brain volumetry through MRI volumetric reconstruction and segmentation

    Science.gov (United States)

    Estroff, Judy A.; Barnewolt, Carol E.; Connolly, Susan A.; Warfield, Simon K.

    2013-01-01

    Purpose Fetal MRI volumetry is a useful technique but it is limited by a dependency upon motion-free scans, tedious manual segmentation, and spatial inaccuracy due to thick-slice scans. An image processing pipeline that addresses these limitations was developed and tested. Materials and methods The principal sequences acquired in fetal MRI clinical practice are multiple orthogonal single-shot fast spin echo scans. State-of-the-art image processing techniques were used for inter-slice motion correction and super-resolution reconstruction of high-resolution volumetric images from these scans. The reconstructed volume images were processed with intensity non-uniformity correction and the fetal brain extracted by using supervised automated segmentation. Results Reconstruction, segmentation and volumetry of the fetal brains for a cohort of twenty-five clinically acquired fetal MRI scans was done. Performance metrics for volume reconstruction, segmentation and volumetry were determined by comparing to manual tracings in five randomly chosen cases. Finally, analysis of the fetal brain and parenchymal volumes was performed based on the gestational age of the fetuses. Conclusion The image processing pipeline developed in this study enables volume rendering and accurate fetal brain volumetry by addressing the limitations of current volumetry techniques, which include dependency on motion-free scans, manual segmentation, and inaccurate thick-slice interpolation. PMID:20625848

  6. A Novel Technique for Fetal ECG Extraction Using Single-Channel Abdominal Recording

    Directory of Open Access Journals (Sweden)

    Nannan Zhang

    2017-02-01

    Full Text Available Non-invasive fetal electrocardiograms (FECGs are an alternative method to standard means of fetal monitoring which permit long-term continual monitoring. However, in abdominal recording, the FECG amplitude is weak in the temporal domain and overlaps with the maternal electrocardiogram (MECG in the spectral domain. Research in the area of non-invasive separations of FECG from abdominal electrocardiograms (AECGs is in its infancy and several studies are currently focusing on this area. An adaptive noise canceller (ANC is commonly used for cancelling interference in cases where the reference signal only correlates with an interference signal, and not with a signal of interest. However, results from some existing studies suggest that propagation of electrocardiogram (ECG signals from the maternal heart to the abdomen is nonlinear, hence the adaptive filter approach may fail if the thoracic and abdominal MECG lack strict waveform similarity. In this study, singular value decomposition (SVD and smooth window (SW techniques are combined to build a reference signal in an ANC. This is to avoid the limitation that thoracic MECGs recorded separately must be similar to abdominal MECGs in waveform. Validation of the proposed method with r01 and r07 signals from a public dataset, and a self-recorded private dataset showed that the proposed method achieved F1 scores of 99.61%, 99.28% and 98.58%, respectively for the detection of fetal QRS. Compared with four other single-channel methods, the proposed method also achieved higher accuracy values of 99.22%, 98.57% and 97.21%, respectively. The findings from this study suggest that the proposed method could potentially aid accurate extraction of FECG from MECG recordings in both clinical and commercial applications.

  7. Four-chamber view and 'swing technique' (FAST) echo: a novel and simple algorithm to visualize standard fetal echocardiographic planes.

    Science.gov (United States)

    Yeo, L; Romero, R; Jodicke, C; Oggè, G; Lee, W; Kusanovic, J P; Vaisbuch, E; Hassan, S

    2011-04-01

    To describe a novel and simple algorithm (four-chamber view and 'swing technique' (FAST) echo) for visualization of standard diagnostic planes of fetal echocardiography from dataset volumes obtained with spatiotemporal image correlation (STIC) and applying a new display technology (OmniView). We developed an algorithm to image standard fetal echocardiographic planes by drawing four dissecting lines through the longitudinal view of the ductal arch contained in a STIC volume dataset. Three of the lines are locked to provide simultaneous visualization of targeted planes, and the fourth line (unlocked) 'swings' through the ductal arch image (swing technique), providing an infinite number of cardiac planes in sequence. Each line generates the following plane(s): (a) Line 1: three-vessels and trachea view; (b) Line 2: five-chamber view and long-axis view of the aorta (obtained by rotation of the five-chamber view on the y-axis); (c) Line 3: four-chamber view; and (d) 'swing line': three-vessels and trachea view, five-chamber view and/or long-axis view of the aorta, four-chamber view and stomach. The algorithm was then tested in 50 normal hearts in fetuses at 15.3-40 weeks' gestation and visualization rates for cardiac diagnostic planes were calculated. To determine whether the algorithm could identify planes that departed from the normal images, we tested the algorithm in five cases with proven congenital heart defects. In normal cases, the FAST echo algorithm (three locked lines and rotation of the five-chamber view on the y-axis) was able to generate the intended planes (longitudinal view of the ductal arch, pulmonary artery, three-vessels and trachea view, five-chamber view, long-axis view of the aorta, four-chamber view) individually in 100% of cases (except for the three-vessels and trachea view, which was seen in 98% (49/50)) and simultaneously in 98% (49/50). The swing technique was able to generate the three-vessels and trachea view, five-chamber view and/or long

  8. Self-gating MR imaging of the fetal heart: comparison with real cardiac triggering

    International Nuclear Information System (INIS)

    Yamamura, Jin; Frisch, Michael; Ecker, Hannes; Adam, Gerhard; Wedegaertner, Ulrike; Graessner, Joachim; Hecher, Kurt

    2011-01-01

    To investigate the self-gating technique for MR imaging of the fetal heart in a sheep model. MR images of 6 fetal sheep heart were obtained at 1.5T. For self-gating MRI of the fetal heart a cine SSFP in short axis, two and four chamber view was used. Self-gated images were compared with real cardiac triggered MR images (pulse-wave triggering). MRI of the fetal heart was performed using both techniques simultaneously. Image quality was assessed and the left ventricular volume and function were measured and compared. Compared with pulse-wave triggering, the self-gating technique produced slightly inferior images with artifacts. Especially the atrial septum could not be so clearly depicted. The contraction of the fetal heart was shown in cine sequences in both techniques. The average blood volumes could be measured with both techniques with no significant difference: at end-systole 3.1 ml (SD± 0.2), at end-diastole 4.9 ml (±0.2), with ejection fractions at 38.6%, respectively 39%. Both self-gating and pulse-wave triggered cardiac MRI of the fetal heart allowed the evaluation of anatomical structures and functional information. Images obtained by self-gating technique were slightly inferior than the pulse-wave triggered MRI. (orig.)

  9. Towards a new era in fetal medicine in the Nordic countries

    DEFF Research Database (Denmark)

    Sitras, Vasilis; Brodszki, Jana; Carlsson, Ylva

    2016-01-01

    Fetal medicine is a subspecialty of obstetrics investigating the development, growth and disease of the human fetus. The advances in fetal imaging (ultrasonography, MRI) and molecular diagnostic techniques, together with the possibility of intervention in utero, make fetal medicine an important, ...

  10. MRI of normal and pathological fetal lung development

    International Nuclear Information System (INIS)

    Kasprian, Gregor; Balassy, Csilla; Brugger, Peter C.; Prayer, Daniela

    2006-01-01

    Normal fetal lung development is a complex process influenced by mechanical and many biochemical factors. In addition to ultrasound, fetal magnetic resonance imaging (MRI) constitutes a new method to investigate this process in vivo during the second and third trimester. The techniques of MRI volumetry, assessment of signal intensities, and MRI spectroscopy of the fetal lung have been used to analyze this process and have already been applied clinically to identify abnormal fetal lung growth. Particularly in conditions such as oligohydramnios and congenital diaphragmatic hernia (CDH), pulmonary hypoplasia may be the cause of neonatal death. A precise diagnosis and quantification of compromised fetal lung development may improve post- and perinatal management. The main events in fetal lung development are reviewed and MR volumetric data from 106 normal fetuses, as well as different examples of pathological lung growth, are provided

  11. MRI of normal and pathological fetal lung development

    Energy Technology Data Exchange (ETDEWEB)

    Kasprian, Gregor [University Clinic of Radiodiagnostics, Medical University of Vienna (Austria)]. E-mail: gregor.kasprian@meduniwien.ac.at; Balassy, Csilla [University Clinic of Radiodiagnostics, Medical University of Vienna (Austria); Brugger, Peter C. [Center of Anatomy and Cell Biology, Medical University of Vienna (Austria); Prayer, Daniela [University Clinic of Radiodiagnostics, Medical University of Vienna (Austria)

    2006-02-15

    Normal fetal lung development is a complex process influenced by mechanical and many biochemical factors. In addition to ultrasound, fetal magnetic resonance imaging (MRI) constitutes a new method to investigate this process in vivo during the second and third trimester. The techniques of MRI volumetry, assessment of signal intensities, and MRI spectroscopy of the fetal lung have been used to analyze this process and have already been applied clinically to identify abnormal fetal lung growth. Particularly in conditions such as oligohydramnios and congenital diaphragmatic hernia (CDH), pulmonary hypoplasia may be the cause of neonatal death. A precise diagnosis and quantification of compromised fetal lung development may improve post- and perinatal management. The main events in fetal lung development are reviewed and MR volumetric data from 106 normal fetuses, as well as different examples of pathological lung growth, are provided.

  12. Predicting intrapartum fetal compromise using the fetal cerebro-umbilical ratio.

    Science.gov (United States)

    Sabdia, S; Greer, R M; Prior, T; Kumar, S

    2015-05-01

    The aim of this study was to explore the association between the cerebro-umbilical ratio measured at 35-37 weeks and intrapartum fetal compromise. This retrospective cross sectional study was conducted at the Mater Mothers' Hospital in Brisbane, Australia. Maternal demographics and fetal Doppler indices at 35-37 weeks gestation for 1381 women were correlated with intrapartum and neonatal outcomes. Babies born by caesarean section or instrumental delivery for fetal compromise had the lowest median cerebro-umbilical ratio 1.60 (IQR 1.22-2.08) compared to all other delivery groups (vaginal delivery, emergency delivery for failure to progress, emergency caesarean section for other reasons or elective caesarean section). The percentage of infants with a cerebro-umbilical ratio cerebro-umbilical ratio between the 10th-90th centile and 9.6% of infants with a cerebro-umbilical ratio > 90th centile required delivery for the same indication (p cerebro-umbilical ratio was associated with an increased risk of emergency delivery for fetal compromise, OR 2.03 (95% CI 1.41-2.92), p cerebro-umbilical ratio measured at 35-37 weeks is associated with a greater risk of intrapartum compromise. This is a relatively simple technique which could be used to risk stratify women in diverse healthcare settings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Telefetalcare: a first prototype of a wearable fetal electrocardiograph.

    Science.gov (United States)

    Fanelli, A; Signorini, M G; Ferrario, M; Perego, P; Piccini, L; Andreoni, G; Magenes, G

    2011-01-01

    Fetal heart rate monitoring is fundamental to infer information about fetal health state during pregnancy. The cardiotocography (CTG) is the most common antepartum monitoring technique. Abdominal ECG recording represents the most valuable alternative to cardiotocography, as it allows passive, non invasive and long term fetal monitoring. Unluckily fetal ECG has low SNR and needs to be extracted from abdominal recordings using ad hoc algorithms. This work describes a prototype of a wearable fetal ECG electrocardiograph. The system has flat band frequency response between 1-60 Hz and guarantees good signal quality. It was tested on pregnant women between the 30(th) and 34(th) gestational week. Several electrodes configurations were tested, in order to identify the best solution. Implementation of a simple algorithm for FECG extraction permitted the reliable detection of maternal and fetal QRS complexes. The system will allow continuative and deep screening of fetal heart rate, introducing the possibility of home fetal monitoring.

  14. Fetal dose from radiotherapy photon beams: Physical basis, techniques to estimate radiation dose outside of the treatment field, biological effects and professional considerations

    International Nuclear Information System (INIS)

    Stovell, Marilyn; Blackwell, C. Robert

    1997-01-01

    Purpose/Objective: The presentation will review: 1. The physical basis of radiation dose outside of the treatment field. 2. Techniques to estimate and reduce fetal dose. 3. Clinical examples of fetal dose estimation and reduction. 4. Biological effects of fetal irradiation. 5. Professional considerations. Approximately 4000 women per year in the United States require radiotherapy during pregnancy. This report presents data and techniques that allow the medical physicist to estimate the radiation dose the fetus will receive and to reduce this dose with appropriate shielding. Out-of-beam data are presented for a variety of photon beams, including cobalt-60 gamma rays and x rays from 4 to 18 MV. Designs for simple and inexpensive to more complex and expensive types of shielding equipment are described. Clinical examples show that proper shielding can reduce the radiation dose to the fetus by 50%. In addition, a review of the biological aspects of irradiation enables estimates of the risks of lethality, growth retardation, mental retardation, malformation, sterility, cancer induction, and genetic defects to the fetus. A summary of professional considerations/recommendations is also provided as a guide for the radiation oncologist and medical physicist

  15. Biomedical Instruments for Fetal and Neonatal Surveillance

    International Nuclear Information System (INIS)

    Rolfe, P; Scopesi, F; Serra, G

    2006-01-01

    Specialised instruments have been developed to aid the care of the fetus and the newborn baby. Miniature sensors using optical, electrical, chemical, mechanical and magnetic principles have been produced for capturing key measurands. These include temperature, pressure, flow and dimension, as well as several specific molecules such as glucose, oxygen and carbon dioxide. During pregnancy ultrasound imaging and blood flow techniques provide valuable information concerning fetal abnormalities, fetal growth, fetal breathing and fetal heart rate. Signal processing and pattern recognition can be useful for deriving indicators of fetal distress and clinical status, based on biopotentials as well as ultrasound signals. Fetal pH measurement is a critical requirement during labour and delivery. The intensive care of ill preterm babies involves provision of an optimal thermal environment and respiratory support. Monitoring of blood gas and acid-base status is essential, and this involves both blood sampling for in vitro analysis as well as the use of invasive or non-invasive sensors. For the future it will be vital that the technologies used are subjected to controlled trials to establish benefit or otherwise

  16. Magnetic resonance angiography of fetal vasculature at 3.0 T

    Science.gov (United States)

    Krishnamurthy, Uday; Jella, Pavan K.; Mody, Swati S.; Yadav, Brijesh K.; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D.; Haacke, Ewart M.; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. PMID:27189488

  17. Magnetic resonance angiography of fetal vasculature at 3.0 T

    International Nuclear Information System (INIS)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Yadav, Brijesh K.; Haacke, Ewart M.; Jella, Pavan K.; Hendershot, Kelly; Cabrera, Maria D.; Mody, Swati S.; Hernandez-Andrade, Edgar; Yeo, Lami; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. (orig.)

  18. Magnetic resonance angiography of fetal vasculature at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Yadav, Brijesh K.; Haacke, Ewart M. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Wayne State University, Department of Biomedical Engineering, Detroit, MI (United States); Jella, Pavan K.; Hendershot, Kelly; Cabrera, Maria D. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Mody, Swati S. [Wayne State University School of Medicine, Department of Radiology, Detroit, MI (United States); Children' s Hospital of Michigan, Department of Radiology, Detroit, MI (United States); Hernandez-Andrade, Edgar; Yeo, Lami; Hassan, Sonia S. [Wayne State University, Department of Obstetrics and Gynecology, Detroit, MI (United States); Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI (United States); Romero, Roberto [Perinatology Research Branch, NICHD/NIH/DHHS, Bethesda, MD, and Detroit, MI (United States); University of Michigan, Department of Obstetrics and Gynecology, Ann Arbor, MI (United States); Michigan State University, Department of Epidemiology and Biostatistics, East Lansing, MI (United States); Wayne State University, Center for Molecular Medicine and Genetics, Detroit, MI (United States)

    2016-12-15

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. (orig.)

  19. A Comparative Study on Fetal Heart Rates Estimated from Fetal Phonography and Cardiotocography

    Directory of Open Access Journals (Sweden)

    Emad A. Ibrahim

    2017-10-01

    Full Text Available The aim of this study is to investigate that fetal heart rates (fHR extracted from fetal phonocardiography (fPCG could convey similar information of fHR from cardiotocography (CTG. Four-channel fPCG sensors made of low cost (<$1 ceramic piezo vibration sensor within 3D-printed casings were used to collect abdominal phonogram signals from 20 pregnant mothers (>34 weeks of gestation. A novel multi-lag covariance matrix-based eigenvalue decomposition technique was used to separate maternal breathing, fetal heart sounds (fHS and maternal heart sounds (mHS from abdominal phonogram signals. Prior to the fHR estimation, the fPCG signals were denoised using a multi-resolution wavelet-based filter. The proposed source separation technique was first tested in separating sources from synthetically mixed signals and then on raw abdominal phonogram signals. fHR signals extracted from fPCG signals were validated using simultaneous recorded CTG-based fHR recordings.The experimental results have shown that the fHR derived from the acquired fPCG can be used to detect periods of acceleration and deceleration, which are critical indication of the fetus' well-being. Moreover, a comparative analysis demonstrated that fHRs from CTG and fPCG signals were in good agreement (Bland Altman plot has mean = −0.21 BPM and ±2 SD = ±3 with statistical significance (p < 0.001 and Spearman correlation coefficient ρ = 0.95. The study findings show that fHR estimated from fPCG could be a reliable substitute for fHR from the CTG, opening up the possibility of a low cost monitoring tool for fetal well-being.

  20. Bio-magnetic signatures of fetal breathing movement

    International Nuclear Information System (INIS)

    Ulusar, U D; Wilson, J D; Murphy, P; Govindan, R B; Preissl, H; Lowery, C L; Eswaran, H

    2011-01-01

    The purpose of fetal magnetoencephalography (fMEG) is to record and analyze fetal brain activity. Unavoidably, these recordings consist of a complex mixture of bio-magnetic signals from both mother and fetus. The acquired data include biological signals that are related to maternal and fetal heart function as well as fetal gross body and breathing movements. Since fetal breathing generates a significant source of bio-magnetic interference during these recordings, the goal of this study was to identify and quantify the signatures pertaining to fetal breathing movements (FBM). The fMEG signals were captured using superconducting quantum interference devices (SQUIDs) The existence of FBM was verified and recorded concurrently by an ultrasound-based video technique. This simultaneous recording is challenging since SQUIDs are extremely sensitive to magnetic signals and highly susceptible to interference from electronic equipment. For each recording, an ultrasound-FBM (UFBM) signal was extracted by tracing the displacement of the boundary defined by the fetal thorax frame by frame. The start of each FBM was identified by using the peak points of the UFBM signal. The bio-magnetic signals associated with FBM were obtained by averaging the bio-magnetic signals time locked to the FBMs. The results showed the existence of a distinctive sinusoidal signal pattern of FBM in fMEG data

  1. Fetal motion estimation from noninvasive cardiac signal recordings.

    Science.gov (United States)

    Biglari, Hadis; Sameni, Reza

    2016-11-01

    Fetal motility is a widely accepted indicator of the well-being of a fetus. In previous research, it has be shown that fetal motion (FM) is coherent with fetal heart rate accelerations and an indicator for active/rest cycles of the fetus. The most common approach for FM and fetal heart rate (FHR) assessment is by Doppler ultrasound (DUS). While DUS is the most common approach for studying the mechanical activities of the heart, noninvasive fetal electrocardiogram (ECG) and magnetocardiogram (MCG) recording and processing techniques have been considered as a possible competitor (or complement) for the DUS. In this study, a fully automatic and robust framework is proposed for the extraction, ranking and alignment of fetal QRS-complexes from noninvasive fetal ECG/MCG. Using notions from subspace tracking, two measures, namely the actogram and rotatogram, are defined for fetal motion tracking. The method is applied to four fetal ECG/MCG databases, including twin MCG recordings. By defining a novel measure of causality, it is shown that there is significant coherency and causal relationship between the actogram/rotatogram and FHR accelerations/decelerations. Using this measure, it is shown that in many cases, the actogram and rotatogram precede the FHR variations, which supports the idea of motion-induced FHR accelerations/decelerations for these cases and raises attention for the non-motion-induced FHR variations, which can be associated to the fetal central nervous system developments. The results of this study can lead to novel perspectives of the fetal sympathetic and parasympathetic brain systems and future requirements of fetal cardiac monitoring.

  2. Anatomy of the normal fetal heart: The basis for understanding fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Beatriz Picazo-Angelin

    2018-01-01

    Full Text Available The rapid changes that have taken place in recent years in relation to techniques used to image the fetal heart have emphasized the need to have a detailed knowledge ofnormal cardiac anatomy. Without such knowledge, it is difficult, if not impossible, to recognize the multiple facets of congenital cardiac disease. From the inception of fetal echocardiographic screening, the importance of basic knowledge of cardiac anatomy has been well recognized. The current machines used for imaging, however, now make it possible potentially to recognize features not appreciated at the start of the specialty. So as to match the advances made in imaging, we have now revisited our understanding of normal cardiac anatomy in the mid-gestational fetus. This was made possible by our dissection of 10 fetal hearts, followed by production of addition histological sections that mimic the standard ultrasound views. The fetuses ranged in gestational age from between 20 and 28 weeks. We then correlated the obtained anatomic images with the corresponding ultrasonic images used in the standard fetal screening scan. We also interrogated the anatomic sections so as to clarify ongoing controversies regarding detailed features of the normal cardiac anatomy. We have been able to show that the views now obtained using current technology reveal many details of anatomy not always appreciated at earlier times. Knowledge of these features should now permit diagnosis of most congenital cardiac malformations. The anatomic-echocardiographic correlations additionally provide a valuable resource for both the understanding and teaching of fetal echocardiography.

  3. Fetal movement detection based on QRS amplitude variations in abdominal ECG recordings.

    Science.gov (United States)

    Rooijakkers, M J; de Lau, H; Rabotti, C; Oei, S G; Bergmans, J W M; Mischi, M

    2014-01-01

    Evaluation of fetal motility can give insight in fetal health, as a strong decrease can be seen as a precursor to fetal death. Typically, the assessment of fetal health by fetal movement detection relies on the maternal perception of fetal activity. The percentage of detected movements is strongly subject dependent and with undivided attention of the mother varies between 37% to 88%. Various methods to assist in fetal movement detection exist based on a wide spectrum of measurement techniques. However, these are typically unsuitable for ambulatory or long-term observation. In this paper, a novel method for fetal motion detection is presented based on amplitude and shape changes in the abdominally recorded fetal ECG. The proposed method has a sensitivity and specificity of 0.67 and 0.90, respectively, outperforming alternative fetal ECG-based methods from the literature.

  4. Eleven fetal echocardiographic planes using 4-dimensional ultrasound with spatio-temporal image correlation (STIC): a logical approach to fetal heart volume analysis.

    Science.gov (United States)

    Jantarasaengaram, Surasak; Vairojanavong, Kittipong

    2010-09-15

    Theoretically, a cross-sectional image of any cardiac planes can be obtained from a STIC fetal heart volume dataset. We described a method to display 11 fetal echocardiographic planes from STIC volumes. Fetal heart volume datasets were acquired by transverse acquisition from 200 normal fetuses at 15 to 40 weeks of gestation. Analysis of the volume datasets using the described technique to display 11 echocardiographic planes in the multiplanar display mode were performed offline. Volume datasets from 18 fetuses were excluded due to poor image resolution. The mean visualization rates for all echocardiographic planes at 15-17, 18-22, 23-27, 28-32 and 33-40 weeks of gestation fetuses were 85.6% (range 45.2-96.8%, N = 31), 92.9% (range 64.0-100%, N = 64), 93.4% (range 51.4-100%, N = 37), 88.7%(range 54.5-100%, N = 33) and 81.8% (range 23.5-100%, N = 17) respectively. Overall, the applied technique can favorably display the pertinent echocardiographic planes. Description of the presented method provides a logical approach to explore the fetal heart volumes.

  5. Computational fluid dynamics (CFD) study on the fetal aortic coarctation

    Science.gov (United States)

    Zhou, Yue; Zhang, Yutao; Wang, Jingying

    2018-03-01

    Blood flows in normal and coarctate fetal aortas are simulated by the CFD technique using T-rex grids. The three-dimensional (3-D) digital model of the fetal arota is reconstructed by the computer-aided design (CAD) software based on two-dimensional (2-D) ultrasono tomographic images. Simulation results displays the development and enhancement of the secondary flow structure in the coarctate fetal arota. As the diameter narrow ratio rises greater than 45%, the pressure and wall shear stress (WSS) of the aorta arch increase exponentially, which is consistent with the conventional clinical concept. The present study also demonstrates that CFD is a very promising assistant technique to investigate human cardiovascular diseases.

  6. Fetal echocardiography

    International Nuclear Information System (INIS)

    Chaubal, Nitin G.; Chaubal, Jyoti

    2009-01-01

    USG performed with a high-end machine, using a good cine-loop facility is extremely helpful in the diagnosis of fetal cardiac anomalies. In fetal echocardiography, the four-chamber view and the outflow-tract view are used to diagnose cardiac anomalies. The most important objective during a targeted anomaly scan is to identify those cases that need a dedicated fetal echocardiogram. Associated truncal and chromosomal anomalies need to be identified. This review shows how fetal echocardiography, apart from identifying structural defects in the fetal heart, can be used to look at rhythm abnormalities and other functional aspects of the fetal heart

  7. 3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements.

    Science.gov (United States)

    Pier, Danielle B; Gholipour, Ali; Afacan, Onur; Velasco-Annis, Clemente; Clancy, Sean; Kapur, Kush; Estroff, Judy A; Warfield, Simon K

    2016-09-01

    Current diagnosis of fetal posterior fossa anomalies by sonography and conventional MRI is limited by fetal position, motion, and by two-dimensional (2D), rather than three-dimensional (3D), representation. In this study, we aimed to validate the use of a novel magnetic resonance imaging (MRI) technique, 3D super-resolution motion-corrected MRI, to image the fetal posterior fossa. From a database of pregnant women who received fetal MRIs at our institution, images of 49 normal fetal brains were reconstructed. Six measurements of the cerebellum, vermis, and pons were obtained for all cases on 2D conventional and 3D reconstructed MRI, and the agreement between the two methods was determined using concordance correlation coefficients. Concordance of axial and coronal measurements of the transcerebellar diameter was also assessed within each method. Between the two methods, the concordance of measurements was high for all six structures (P fetal motion and orthogonal slice acquisition. This technique will facilitate further study of fetal abnormalities of the posterior fossa. Copyright © 2016 by the American Society of Neuroimaging.

  8. A robust physiology-based source separation method for QRS detection in low amplitude fetal ECG recordings

    International Nuclear Information System (INIS)

    Vullings, R; Bergmans, J W M; Peters, C H L; Hermans, M J M; Wijn, P F F; Oei, S G

    2010-01-01

    The use of the non-invasively obtained fetal electrocardiogram (ECG) in fetal monitoring is complicated by the low signal-to-noise ratio (SNR) of ECG signals. Even after removal of the predominant interference (i.e. the maternal ECG), the SNR is generally too low for medical diagnostics, and hence additional signal processing is still required. To this end, several methods for exploiting the spatial correlation of multi-channel fetal ECG recordings from the maternal abdomen have been proposed in the literature, of which principal component analysis (PCA) and independent component analysis (ICA) are the most prominent. Both PCA and ICA, however, suffer from the drawback that they are blind source separation (BSS) techniques and as such suboptimum in that they do not consider a priori knowledge on the abdominal electrode configuration and fetal heart activity. In this paper we propose a source separation technique that is based on the physiology of the fetal heart and on the knowledge of the electrode configuration. This technique operates by calculating the spatial fetal vectorcardiogram (VCG) and approximating the VCG for several overlayed heartbeats by an ellipse. By subsequently projecting the VCG onto the long axis of this ellipse, a source signal of the fetal ECG can be obtained. To evaluate the developed technique, its performance is compared to that of both PCA and ICA and to that of augmented versions of these techniques (aPCA and aICA; PCA and ICA applied on preprocessed signals) in generating a fetal ECG source signal with enhanced SNR that can be used to detect fetal QRS complexes. The evaluation shows that the developed source separation technique performs slightly better than aPCA and aICA and outperforms PCA and ICA and has the main advantage that, with respect to aPCA/PCA and aICA/ICA, it performs more robustly. This advantage renders it favorable for employment in automated, real-time fetal monitoring applications

  9. Applicability of three-dimensional imaging techniques in fetal medicine*

    Science.gov (United States)

    Werner Júnior, Heron; dos Santos, Jorge Lopes; Belmonte, Simone; Ribeiro, Gerson; Daltro, Pedro; Gasparetto, Emerson Leandro; Marchiori, Edson

    2016-01-01

    Objective To generate physical models of fetuses from images obtained with three-dimensional ultrasound (3D-US), magnetic resonance imaging (MRI), and, occasionally, computed tomography (CT), in order to guide additive manufacturing technology. Materials and Methods We used 3D-US images of 31 pregnant women, including 5 who were carrying twins. If abnormalities were detected by 3D-US, both MRI and in some cases CT scans were then immediately performed. The images were then exported to a workstation in DICOM format. A single observer performed slice-by-slice manual segmentation using a digital high resolution screen. Virtual 3D models were obtained from software that converts medical images into numerical models. Those models were then generated in physical form through the use of additive manufacturing techniques. Results Physical models based upon 3D-US, MRI, and CT images were successfully generated. The postnatal appearance of either the aborted fetus or the neonate closely resembled the physical models, particularly in cases of malformations. Conclusion The combined use of 3D-US, MRI, and CT could help improve our understanding of fetal anatomy. These three screening modalities can be used for educational purposes and as tools to enable parents to visualize their unborn baby. The images can be segmented and then applied, separately or jointly, in order to construct virtual and physical 3D models. PMID:27818540

  10. Applicability of three-dimensional imaging techniques in fetal medicine

    Energy Technology Data Exchange (ETDEWEB)

    Werner Junior, Heron; Daltro, Pedro; Gasparetto, Emerson Leandro, E-mail: heronwerner@hotmail.com [Clinica de Diagnostico Por Imagem (CDPI), Rio de Janeiro, RJ (Brazil); Santos, Jorge Lopes dos; Belmonte, Simone; Ribeiro, Gerson [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil)

    2016-09-15

    Objective: To generate physical models of fetuses from images obtained with three-dimensional ultrasound (3D-US), magnetic resonance imaging (MRI), and, occasionally, computed tomography (CT), in order to guide additive manufacturing technology. Materials and Methods: We used 3D-US images of 31 pregnant women, including 5 who were carrying twins. If abnormalities were detected by 3D-US, both MRI and in some cases CT scans were then immediately performed. The images were then exported to a workstation in DICOM format. A single observer performed slice-by-slice manual segmentation using a digital high resolution screen. Virtual 3D models were obtained from software that converts medical images into numerical models. Those models were then generated in physical form through the use of additive manufacturing techniques. Results: Physical models based upon 3D-US, MRI, and CT images were successfully generated. The postnatal appearance of either the aborted fetus or the neonate closely resembled the physical models, particularly in cases of malformations. Conclusion: The combined use of 3D-US, MRI, and CT could help improve our understanding of fetal anatomy. These three screening modalities can be used for educational purposes and as tools to enable parents to visualize their unborn baby. The images can be segmented and then applied, separately or jointly, in order to construct virtual and physical 3D models. (author)

  11. Analysis of fetal movements by Doppler actocardiogram and fetal B-mode imaging.

    Science.gov (United States)

    Maeda, K; Tatsumura, M; Utsu, M

    1999-12-01

    We have presented that fetal surveillance may be enhanced by use of the fetal actocardiogram and by computerized processing of fetal motion as well as fetal B-mode ultrasound imaging. Ultrasonic Doppler fetal actogram is a sensitive and objective method for detecting and recording fetal movements. Computer processing of the actograph output signals enables powerful, detailed, and convenient analysis of fetal physiologic phenomena. The actocardiogram is a useful measurement tool not only in fetal behavioral studies but also in evaluation of fetal well-being. It reduces false-positive, nonreactive NST and false-positive sinusoidal FHR pattern. It is a valuable tool to predict fetal distress. The results of intrapartum fetal monitoring are further improved by the antepartum application of the actocardiogram. Quantified fetal motion analysis is a useful, objective evaluation of the embryo and fetus. This method allows monitoring of changes in fetal movement, as well as frequency, amplitude, and duration. Furthermore, quantification of fetal motion enables evaluation of fetal behavior states and how these states relate to other measurements, such as changes in FHR. Numeric analysis of both fetal actogram and fetal motion from B-mode images is a promising application in the correlation of fetal activity or behavior with other fetal physiologic measurements.

  12. MRI of the fetal abdomen; MRT des fetalen Abdomens

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, M.; Brugger, P.C.; Witzani, L.; Prayer, D. [Medizinische Universitaet Wien (Austria). Universitaetsklinik fuer Radiodiagnostik

    2006-02-15

    Magnetic resonance imaging (MRI) is an important diagnostic component for central nervous system and thoracic diseases during fetal development. Although ultrasound remains the method of choice for observing the fetus during pregnancy, fetal MRI is being increasingly used as an additional technique for the accurate diagnosis of abdominal diseases. Recent publications confirm the value of MRI in the diagnosis of fetal gastrointestinal tract and urogenital system diseases. The following report provides an overview of MRI-examination techniques for the most frequent diseases of the abdomen. (orig.) [German] Die MRT ist ein wichtiger Bestandteil zur Diagnostik des zentralen Nervensystems und thorakaler Erkrankungen in der fetalen Entwicklung. Wenngleich der Ultraschall die Methode der Wahl zur Ueberwachung des Feten in der Schwangerschaft bleibt, bekommt die fetale MRT als zusaetzliche Untersuchungstechnik zur akkuraten Diagnostik abdomineller Erkrankungen immer groessere Bedeutung. Die neueren Publikationen bestaetigen v. a. den Stellenwert der MRT in der Diagnose von Erkrankungen des fetalen Gastrointestinaltrakts und des Urogenitalsystems. Im Folgenden soll ein Ueberblick ueber die MR-Untersuchungstechnik der haeufigsten Erkrankungen des Abdomens gegeben werden. (orig.)

  13. Intrapartum fetal heart rate profiles with and without fetal asphyxia.

    Science.gov (United States)

    Low, J A; Pancham, S R; Worthington, D N

    1977-04-01

    Fetal heart rate profiles for periods up to 12 hours prior to delivery have been reviewed in 515 patients with a fetus at risk. Mechanisms other than fetal asphyxia will cause fetal heart rate decelerations, and fetal asphyxia may in some instances develop in the absence of total or late decelerations. However, an increasing incidence of total decelerations and late decelerations and particularly a marked pattern of total decelerations and late decelerations are of value in the prediction of fetal asphyxia. Fetal heart rate deceleration patterns can predict the probability of fetal asphyxia at the time of initial intervention, while a progression of fetal heart rate deceleration patterns in the individual fetus can be of assistance in the subsequent scheduling of serial acid-base assessments during labor.

  14. Magnetic resonance angiography of fetal vasculature at 3.0 T

    OpenAIRE

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Jella, Pavan K.; Mody, Swati S.; Yadav, Brijesh K.; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D.; Haacke, Ewart M.; Hassan, Sonia S.; Romero, Roberto

    2016-01-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possibl...

  15. [Fetal version as ambulatory intervention].

    Science.gov (United States)

    Nohe, G; Hartmann, W; Klapproth, C E

    1996-06-01

    The external cephalic version (ECV) of the fetus at term reduces the maternal and fetal risks of intrapartum breech presentation and Caesarean delivery. Since 1986 over 800 external cephalic versions were performed in the outpatient Department of Obstetrics and Gynaecology of the Städtische Frauenklinik Stuttgart. 60.5% were successful. NO severe complications occurred. Sufficient amniotic fluid as well as the mobility of the fetal breech is a major criterion for the success of the ECV. Management requires a safe technique for mother and fetus. This includes ultrasonography, elektronic fetal monitoring and the ability to perform immediate caesarean delivery as well as the performance of ECV without analgesicas and sedatives. More than 70% of the ECV were successful without tocolysis. In unsuccessful cases the additional use of tocolysis improves the success rate only slightly. Therefore routine use of tocolysis does not appear necessary. External cephalic version can be recommended as an outpatient treatment without tocolysis.

  16. The effect of fetal sex on customized fetal growth charts.

    Science.gov (United States)

    Rizzo, Giuseppe; Prefumo, Federico; Ferrazzi, Enrico; Zanardini, Cristina; Di Martino, Daniela; Boito, Simona; Aiello, Elisa; Ghi, Tullio

    2016-12-01

    To evaluate the effect of fetal sex on singleton pregnancy growth charts customized for parental characteristics, race, and parity Methods: In a multicentric cross-sectional study, 8070 ultrasonographic examinations from low-risk singleton pregnancies between 16 and 40 weeks of gestation were considered. The fetal measurements obtained were biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL). Quantile regression was used to examine the impact of fetal sex across the biometric percentiles of the fetal measurements considered together with parents' height, weight, parity, and race. Fetal gender resulted to be a significant covariate for BDP, HC, and AC with higher values for male fetuses (p ≤ 0.0009). Minimal differences were found among sexes for FL. Parity, maternal race, paternal height and maternal height, and weight resulted significantly related to the fetal biometric parameters considered independently from fetal gender. In this study, we constructed customized biometric growth charts for fetal sex, parental, and obstetrical characteristics using quantile regression. The use of gender-specific charts offers the advantage to define individualized normal ranges of fetal biometric parameters at each specific centile. This approach may improve the antenatal identification of abnormal fetal growth.

  17. Fetal MRI; Fetales MRT

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D. [Inst. fuer Diagn. Radiologie, Uniklinikum Duesseldorf (Germany); Turowski, B. [Inst. fuer Diagn. Radiologie, Neuroradiologie, Uniklinikum Duesseldorf (Germany); Schaper, J. [Inst. fuer Diagn. Radiologie, Kinderradiologie, Uniklinikum Duesseldorf (Germany)

    2007-02-15

    Ultrasonography is the method of choice for prenatal malformation screening, but it does not always provide sufficient information for correct diagnosis or adequate abnormality evaluation. Fetal MRI is increasingly being used to complete sonographic findings. It was initially used for evaluation of cerebral abnormalities but is increasingly being applied to other fetal areas. In vivo investigation of fetal brain maturation has been enhanced by MRI. An adequate analysis of fetal chest and abdomen can be achieved with fast T2-, T1-weighted and diffusion-weighted imaging (DWI). The advantages include the great field of view and the excellent soft tissue contrast. This allows correct diagnosis of congenital diaphragmatic hernia and evaluation of the consequences on pulmonary growth. Other pulmonary malformations, such as cystic adenomatoid malformation, sequestration and brochogenic cysts, can also be easily identified. Renal position can be quickly determined using DWI sequences and renal agenesia can be easily diagnosed with only one sequence. Prenatal MRI is virtually as effective as postnatal examination, dispenses with transport of a potentially very ill newborn, and provides logistic advantages. Therefore, prenatal MRI is useful for adequate postnatal treatment of newborns with malformations. (orig.)

  18. Histochemical and radioautographic studies of normal human fetal colon

    International Nuclear Information System (INIS)

    Lev, R.; Orlic, D.; New York Medical Coll., N.Y.

    1974-01-01

    Twenty fetal and infant colons ranging from 10 weeks in utero to 20 months postpartum, and 12 adult human colons were examined using histochemical techniques in conjunction with in vitro radioautography using Na 2 35 SO 4 as a sulfomucin precursor. Only the sulfated components of mucus in fetal goblet cells was found to differ significantly from adult colonic mucins. In the fetus sulfomucin staining was much weaker than in the adult, and was more intense in the left colon which is the reverse of the adult pattern. Sulfomucin was concentrated in the crypts throughout the fetal colon whereas in the adult right colon it predominated in the surface cells. As in the adult, saponification liberated carboxyl groups, possibly belonging to sialic acid, and vicinal hydroxyl groups from fetal mucins suggesting that this procedure hydrolyses an ester linkage between these 2 reactive groups. During the middle trimester of fetal life the colon possesses villi whose constituent cells display alkaline phosphatase in their surface coat. These and other morphological and histochemical similarities to fetal small intestine suggest that the fetal colon may have a limited capacity to absorb materials contained within swallowed amniotic fluid during this period. (orig.) [de

  19. [Construction of fetal mesenchymal stem cell cDNA subtractive library].

    Science.gov (United States)

    Yang, Li; Wang, Dong-Mei; Li, Liang; Bai, Ci-Xian; Cao, Hua; Li, Ting-Yu; Pei, Xue-Tao

    2002-04-01

    To identify differentially expressed genes between fetal mesenchymal stem cell (MSC) and adult MSC, especially specified genes expressed in fetal MSC, a cDNA subtractive library of fetal MSC was constructed using suppression subtractive hybridization (SSH) technique. At first, total RNA was isolated from fetal and adult MSC. Using SMART PCR synthesis method, single-strand and double-strand cDNAs were synthesized. After Rsa I digestion, fetal MSC cDNAs were divided into two groups and ligated to adaptor 1 and adaptor 2 respectively. Results showed that the amplified library contains 890 clones. Analysis of 890 clones with PCR demonstrated that 768 clones were positive. The positive rate is 86.3%. The size of inserted fragments in these positive clones was between 0.2 - 1 kb, with an average of 400 - 600 bp. SSH is a convenient and effective method for screening differentially expressed genes. The constructed cDNA subtractive library of fetal MSC cDNA lays solid foundation for screening and cloning new and specific function related genes of fetal MSC.

  20. Magnetic resonance angiography of fetal vasculature at 3.0 T.

    Science.gov (United States)

    Neelavalli, Jaladhar; Krishnamurthy, Uday; Jella, Pavan K; Mody, Swati S; Yadav, Brijesh K; Hendershot, Kelly; Hernandez-Andrade, Edgar; Yeo, Lami; Cabrera, Maria D; Haacke, Ewart M; Hassan, Sonia S; Romero, Roberto

    2016-12-01

    Magnetic resonance angiography has not been used much previously for visualizing fetal vessels in utero for reasons that include a contraindication for the use of exogenous contrast agents, maternal respiratory motion and fetal motion. In this work, we report the feasibility of using an appropriately modified clinical time-of-flight magnetic resonance imaging sequence for non-contrast angiography of human fetal and placental vessels at 3.0 T. Using this 2D angiography technique, it is possible to visualize fetal vascular networks in late pregnancy. • 3D-visualization of fetal vasculature is feasible using non-contrast MRA at 3.0 T. • Visualization of placental vasculature is also possible with this method. • Fetal MRA can serve as a vascular localizer for quantitative MRI studies. • This method can be extended to 1.5 T.

  1. Increasing fetal ovine number per gestation alters fetal plasma clinical chemistry values.

    Science.gov (United States)

    Zywicki, Micaela; Blohowiak, Sharon E; Magness, Ronald R; Segar, Jeffrey L; Kling, Pamela J

    2016-08-01

    Intrauterine growth restriction (IUGR) is interconnected with developmental programming of lifelong pathophysiology. IUGR is seen in human multifetal pregnancies, with stepwise rises in fetal numbers interfering with placental nutrient delivery. It remains unknown whether fetal blood analyses would reflect fetal nutrition, liver, and excretory function in the last trimester of human or ovine IUGR In an ovine model, we hypothesized that fetal plasma biochemical values would reflect progressive placental, fetal liver, and fetal kidney dysfunction as the number of fetuses per gestation rose. To determine fetal plasma biochemical values in singleton, twin, triplet, and quadruplet/quintuplet ovine gestation, we investigated morphometric measures and comprehensive metabolic panels with nutritional measures, liver enzymes, and placental and fetal kidney excretory measures at gestational day (GD) 130 (90% gestation). As anticipated, placental dysfunction was supported by a stepwise fall in fetal weight, fetal plasma glucose, and triglyceride levels as fetal number per ewe rose. Fetal glucose and triglycerides were directly related to fetal weight. Plasma creatinine, reflecting fetal renal excretory function, and plasma cholesterol, reflecting placental excretory function, were inversely correlated with fetal weight. Progressive biochemical disturbances and growth restriction accompanied the rise in fetal number. Understanding the compensatory and adaptive responses of growth-restricted fetuses at the biochemical level may help explain how metabolic pathways in growth restriction can be predetermined at birth. This physiological understanding is important for clinical care and generating interventional strategies to prevent altered developmental programming in multifetal gestation. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  2. Fetal neuroimaging: an update on technical advances and clinical findings.

    Science.gov (United States)

    Robinson, Ashley J; Ederies, M Ashraf

    2018-04-01

    This paper is based on a literature review from 2011 to 2016. The paper is divided into two main sections. The first section relates to technical advances in fetal imaging techniques, including fetal motion compensation, imaging at 3.0 T, 3-D T2-weighted MRI, susceptibility-weighted imaging, computed tomography, morphometric analysis, diffusion tensor imaging, spectroscopy and fetal behavioral assessment. The second section relates to clinical updates, including cerebral lamination, migrational anomalies, midline anomalies, neural tube defects, posterior fossa anomalies, sulcation/gyration and hypoxic-ischemic insults.

  3. Fetal thrombocytopenia in pregnancies with fetal human parvovirus-B19 infection.

    Science.gov (United States)

    Melamed, Nir; Whittle, Wendy; Kelly, Edmond N; Windrim, Rory; Seaward, P Gareth R; Keunen, Johannes; Keating, Sarah; Ryan, Greg

    2015-06-01

    Fetal infection with human parvovirus B19 (hParvo-B19) has been associated mainly with fetal anemia, although data regarding other fetal hematologic effects are limited. Our aim was to assess the rate and consequences of severe fetal thrombocytopenia after fetal hParvo-B19 infection. We conducted a retrospective study of pregnancies that were complicated by fetal hParvo-B19 infection that underwent fetal blood sampling (FBS). The characteristics and outcomes of fetuses with severe thrombocytopenia (B19 infection. A total of 37 pregnancies that were affected by fetal hParvo-B19 infection were identified. Of the 29 cases that underwent FBS and had information regarding fetal platelets, 11 cases (38%) were complicated by severe fetal thrombocytopenia. Severely thrombocytopenic fetuses were characterized by a lower hemoglobin concentration (2.6 ± 0.9 g/dL vs 5.5 ± 3.6 g/dL; P = .01), lower reticulocyte count (9.1% ± 2.8% vs 17.3% ± 10.6%; P = .02), and lower gestational age at the time of diagnosis (21.4 ± 3.1 wk vs 23.6 ± 2.2 wk; P = .03). Both the fetal death rate within 48 hours of FBS (27.3% vs 0%; P = .02) and the risk of prematurity (100.0% vs 13.3%; P B19 infection, can be further worsened by IUT, and may be associated with an increased risk of procedure-related fetal loss after either FBS or IUT. Copyright © 2015. Published by Elsevier Inc.

  4. Diagnosis of fetal syndromes by three- and four-dimensional ultrasound: is there any improvement?

    Science.gov (United States)

    Barišić, Lara Spalldi; Stanojević, Milan; Kurjak, Asim; Porović, Selma; Gaber, Ghalia

    2017-08-28

    With all of our present knowledge, high technology diagnostic equipment, electronic databases and other available supporting resources, detection of fetal syndromes is still a challenge for healthcare providers in prenatal as well as in the postnatal period. Prenatal diagnosis of fetal syndromes is not straightforward, and it is a difficult puzzle that needs to be assembled and solved. Detection of one anomaly should always raise a suspicion of the existence of more anomalies, and can be a trigger to investigate further and raise awareness of possible syndromes. Highly specialized software systems for three- and four-dimensional ultrasound (3D/4D US) enabled detailed depiction of fetal anatomy and assessment of the dynamics of fetal structural and functional development in real time. With recent advances in 3D/4D US technology, antenatal diagnosis of fetal anomalies and syndromes shifted from the 2nd to the 1st trimester of pregnancy. It is questionable what can and should be done after the prenatal diagnosis of fetal syndrome. The 3D and 4D US techniques improved detection accuracy of fetal abnormalities and syndromes from early pregnancy onwards. It is not easy to make prenatal diagnosis of fetal syndromes, so tools which help like online integrated databases are needed to increase diagnostic precision. The aim of this paper is to present the possibilities of different US techniques in the detection of some fetal syndromes prenatally.

  5. Evaluation of Subependymal Gray Matter Heterotopias on Fetal MRI.

    Science.gov (United States)

    Nagaraj, U D; Peiro, J L; Bierbrauer, K S; Kline-Fath, B M

    2016-04-01

    Subependymal grey matter heterotopias are seen in a high proportion of children with Chiari II malformation and are potentially clinically relevant. However, despite its growing use, there is little in the literature describing its detection on fetal MRI. Our aim was to evaluate the accuracy in diagnosing subependymal gray matter heterotopias in fetuses with spinal dysraphism on fetal MR imaging. This study is a retrospective analysis of 203 fetal MRIs performed at a single institution for spinal dysraphism during a 10-year period. Corresponding obstetric sonography, postnatal imaging, and clinical/operative reports were reviewed. Of the fetal MRIs reviewed, 95 fetuses were included in our analysis; 23.2% (22/95) were suspected of having subependymal gray matter heterotopias on fetal MR imaging prospectively. However, only 50% (11/22) of these cases were confirmed on postnatal brain MR imaging. On postnatal brain MR imaging, 28.4% (27/95) demonstrated imaging findings consistent with subependymal gray matter heterotopia. Only 40.7% (11/27) of these cases were prospectively diagnosed on fetal MR imaging. Fetal MR imaging is limited in its ability to identify subependymal gray matter heterotopias in fetuses with spinal dysraphism. It is believed that this limitation relates to a combination of factors, including artifacts from fetal motion, the very small size of fetal neuroanatomy, differences in imaging techniques, and, possibly, irregularity related to denudation of the ependyma/subependyma in the presence of spinal dysraphism and/or stretching of the germinal matrix in ventriculomegaly. © 2016 by American Journal of Neuroradiology.

  6. Advanced MRI techniques of the fetal brain; Zukunftsweisende MRT-Techniken des fetalen Gehirns

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, V.; Dittrich, E.; Berger-Kulemann, V.; Kasprian, G.; Kollndorfer, K.; Prayer, D. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2013-02-15

    Evaluation of the normal and pathological fetal brain. Magnetic resonance imaging (MRI). Advanced MRI of the fetal brain. Diffusion tensor imaging (DTI) is used in clinical practice, all other methods are used at a research level. Serving as standard methods in the future. Combined structural and functional data for all gestational ages will allow more specific insight into the developmental processes of the fetal brain. This gain of information will help provide a common understanding of complex spatial and temporal procedures of early morphological features and their impact on cognitive and sensory abilities. (orig.) [German] Evaluierung des gesunden bzw. pathologischen fetalen Gehirns. Die Magnetresonanztomographie. Zukunftsweisende Techniken in der MRT-Bildgebung des fetalen Gehirns. Die Diffusionstensorbildgebung (DTI) befindet sich bereits in der klinischen Anwendung, alle anderen Methoden sind bisher noch als experimentell zu werten. Auf dem Weg zur Etablierung als Standardverfahren. Eine kombinierte Verarbeitung funktioneller und struktureller Daten, modelliert fuer jede Schwangerschaftswoche, wird es zukuenftig ermoeglichen, anhand dieser fusionierten Informationen einen praezisen Einblick in den Entwicklungsprozess des Gehirns zu erlangen. Diese Erkenntnisse und Ergebnisse werden entscheidend zur Klaerung des zeitlichen Verlaufs und des komplexen Aufbaus frueher morphologischer Auffaelligkeiten beitragen sowie deren Einfluss auf kognitive und sensorische Faehigkeiten aufzeigen. (orig.)

  7. Melatonin modulates the fetal cardiovascular defense response to acute hypoxia.

    Science.gov (United States)

    Thakor, Avnesh S; Allison, Beth J; Niu, Youguo; Botting, Kimberley J; Serón-Ferré, Maria; Herrera, Emilio A; Giussani, Dino A

    2015-08-01

    Experimental studies in animal models supporting protective effects on the fetus of melatonin in adverse pregnancy have prompted clinical trials in human pregnancy complicated by fetal growth restriction. However, the effects of melatonin on the fetal defense to acute hypoxia, such as that which may occur during labor, remain unknown. This translational study tested the hypothesis, in vivo, that melatonin modulates the fetal cardiometabolic defense responses to acute hypoxia in chronically instrumented late gestation fetal sheep via alterations in fetal nitric oxide (NO) bioavailability. Under anesthesia, 6 fetal sheep at 0.85 gestation were instrumented with vascular catheters and a Transonic flow probe around a femoral artery. Five days later, fetuses were exposed to acute hypoxia with or without melatonin treatment. Fetal blood was taken to determine blood gas and metabolic status and plasma catecholamine concentrations. Hypoxia during melatonin treatment was repeated during in vivo NO blockade with the NO clamp. This technique permits blockade of de novo synthesis of NO while compensating for the tonic production of the gas, thereby maintaining basal cardiovascular function. Melatonin suppressed the redistribution of blood flow away from peripheral circulations and the glycemic and plasma catecholamine responses to acute hypoxia. These are important components of the fetal brain sparing response to acute hypoxia. The effects of melatonin involved NO-dependent mechanisms as the responses were reverted by fetal treatment with the NO clamp. Melatonin modulates the in vivo fetal cardiometabolic responses to acute hypoxia by increasing NO bioavailability. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Average fetal depth in utero: data for estimation of fetal absorbed radiation dose

    International Nuclear Information System (INIS)

    Ragozzino, M.W.; Breckle, R.; Hill, L.M.; Gray, J.E.

    1986-01-01

    To estimate fetal absorbed dose from radiographic examinations, the depth from the anterior maternal surface to the midline of the fetal skull and abdomen was measured by ultrasound in 97 pregnant women. The relationships between fetal depth, fetal presentation, and maternal parameters of height, weight, anteroposterior (AP) thickness, gestational age, placental location, and bladder volume were analyzed. Maternal AP thickness (MAP) can be estimated from gestational age, maternal height, and maternal weight. Fetal midskull and abdominal depths were nearly equal. Fetal depth normalized to MAP was independent or nearly independent of maternal parameters and fetal presentation. These data enable a reasonable estimation of absorbed dose to fetal brain, abdomen, and whole body

  9. Fetal behavioral teratology.

    Science.gov (United States)

    Visser, Gerard H A; Mulder, Eduard J H; Tessa Ververs, F F

    2010-10-01

    Ultrasound studies of fetal motor behavior provide direct – in vivo – insight in the functioning of the motor component of the fetal central nervous system. In this article, studies are reviewed showing changes in the first timetable of appearance of fetal movements, changes in quality and/or quantity of movements and disturbances in the development of fetal behavioral states in case of endogenous malfunctions, maternal diseases and exogenous behavioral teratogens.

  10. Fetal MEG evoked response latency from beamformer with random field theory.

    Science.gov (United States)

    McCubbin, J; Vrba, J; Murphy, P; Temple, J; Eswaran, H; Lowery, C L; Preissl, H

    2010-01-01

    Analysis of fetal magnetoencephalographic brain recordings is restricted by low signal to noise ratio (SNR) and non-stationarity of the sources. Beamformer techniques have been applied to improve SNR of fetal evoked responses. However, until now the effect of non-stationarity was not taken into account in detail, because the detection of evoked responses is in most cases determined by averaging a large number of trials. We applied a windowing technique to improve the stationarity of the data by using short time segments recorded during a flash-evoked study. In addition, we implemented a random field theory approach for more stringent control of false-positives in the statistical parametric map of the search volume for the beamformer. The search volume was based on detailed individual fetal/maternal biometrics from ultrasound scans and fetal heart localization. Average power over a sliding window within the averaged evoked response against a randomized average background power was used as the test z-statistic. The significance threshold was set at 10% over all members of a contiguous cluster of voxels. There was at least one significant response for 62% of fetal and 95% of newborn recordings with gestational age (GA) between 28 and 45 weeks from 29 subjects. We found that the latency was either substantially unchanged or decreased with increasing GA for most subjects, with a nominal rate of about -11 ms/week. These findings support the anticipated neurophysiological development, provide validation for the beamformer model search as a methodology, and may lead to a clinical test for fetal cognitive development.

  11. Imaging of the fetal central nervous system

    NARCIS (Netherlands)

    Pistorius, L.R.

    2008-01-01

    Introduction : Ultrasound and MR imaging of the fetal central nervous system (CNS) develop at an ever-increasing rate. Theoretically, the two modalities should be synergistic, but a literature review revealed the difficulties of determining the merit of either technique and revealed gaps in our

  12. Fetal echocardiography

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007340.htm Fetal echocardiography To use the sharing features on this page, please enable JavaScript. Fetal echocardiography is a test that uses sound waves ( ultrasound ) ...

  13. Fetal electrocardiogram (ECG) for fetal monitoring during labour.

    Science.gov (United States)

    Neilson, James P

    2015-12-21

    Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average

  14. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  15. Fetal brain damage following maternal carbon monoxide intoxication: an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Ginsberg, M D; Myers, R E

    1974-01-01

    Techniques of fetal monitoring, including fetal blood sampling in utero, were employed to study the physiological effects of acute maternal carbon monoxide intoxication on nine term-pregnant female rhesus monkeys exposed to 0.1 to 0.3% inspired carbon monoxide over 1 to 3 hr. The mothers tolerated carboxyhemoglobin levels exceeding 60% without clinical sequelae, whereas the fetuses promptly developed profound hypoxia upon exposure of the mothers to CO. The fetal COHb levels rose only gradually over 1 to 3 hr, and thus contributed only slightly to the development of early fetal hypoxia. The fetal hypoxia was associated with bradycardia, hypotension, and metabolic and respiratory acidosis. Severity of intrauterine hypoxia was closely correlated with the appearance of brain damage. Brain swelling associated with hemorrhagic necrosis of the cerebral hemispheres (severe brain damage) appeared only in fetuses whose arterial oxygen content was reduced below 1.0 ml/100 ml for at least 45 min during the maternal CO intoxication.

  16. Pulmonary Hypoplasia Caused by Fetal Ascites in Congenital Cytomegalovirus Infection Despite Fetal Therapy

    Directory of Open Access Journals (Sweden)

    Kazumichi Fujioka

    2017-11-01

    Full Text Available We report two cases of pulmonary hypoplasia due to fetal ascites in symptomatic congenital cytomegalovirus (CMV infections despite fetal therapy. The patients died soon after birth. The pathogenesis of pulmonary hypoplasia in our cases might be thoracic compression due to massive fetal ascites as a result of liver insufficiency. Despite aggressive fetal treatment, including multiple immunoglobulin administration, which was supposed to diminish the pathogenic effects of CMV either by neutralization or immunomodulatory effects, the fetal ascites was uncontrollable. To prevent development of pulmonary hypoplasia in symptomatic congenital CMV infections, further fetal intervention to reduce ascites should be considered.

  17. Fetal scalp pH testing

    Science.gov (United States)

    Fetal scalp blood; Scalp pH testing; Fetal blood testing - scalp; Fetal distress - fetal scalp testing; Labor - fetal scalp testing ... a baby. In these cases, testing the scalp pH can help the doctor decide whether the fetus ...

  18. [Incidence of fetal macrosomia: maternal and fetal morbidity].

    Science.gov (United States)

    Rodríguez-Rojas, R R; Cantú-Esquivel, M G; Benavides-de la Garza, L; Benavides-de Anda, L

    1996-06-01

    The macrosomia is an obstetric eventuality associated to high maternal-fetal morbidity-mortality. This assay was planned in order to know the incidence of macrosomia in our institution, the relation between vaginal and abdominal deliveries and the fetal-maternal morbidity we reviewed 3590 records and we found 5.6% incidence of macrosomia in the global obstetric population. There was 58% of vaginal deliveries, 68% of the newborn were male. The main complications were in the C. sections, 2 laceration of the hysterectomy, and 2 peroperative atonias. In the vaginal deliveries, the lacerations of III and IV grade were 9 of each grade. The main fetal complications were 5 slight to severe asphyxia and 4 shoulder dystocias. This assay concludes that the macrosomia in our service is similar to the already published ones, a 42% were C. section and the maternal-fetal morbidity was low.

  19. Adapting Parcellation Schemes to Study Fetal Brain Connectivity in Serial Imaging Studies

    DEFF Research Database (Denmark)

    Cheng, Xi; Wilm, Jakob; Seshamani, Sharmishtaa

    2013-01-01

    A crucial step in studying brain connectivity is the definition of the Regions Of Interest (ROI's) which are considered as nodes of a network graph. These ROI's identified in structural imaging reflect consistent functional regions in the anatomies being compared. However in serial studies...... of the developing fetal brain such functional and associated structural markers are not consistently present over time. In this study we adapt two non-atlas based parcellation schemes to study the development of connectivity networks of a fetal monkey brain using Diffusion Weighted Imaging techniques. Results...... demonstrate that the fetal brain network exhibits small-world characteristics and a pattern of increased cluster coefficients and decreased global efficiency. These findings may provide a route to creating a new biomarker for healthy fetal brain development....

  20. Intermittent Auscultation for Intrapartum Fetal Heart Rate Surveillance: American College of Nurse-Midwives.

    Science.gov (United States)

    2015-01-01

    Fetal heart rate surveillance is a standard component of intrapartum care. The fetal heart rate can be evaluated using intermittent auscultation or electronic fetal monitoring. Research that has compared these 2 strategies found them to be equivalent with respect to long-term neonatal outcomes. The purpose of this clinical bulletin by the American College of Nurse-Midwives is to review the evidence for use of intermittent auscultation and provide recommendations for intermittent auscultation technique, interpretation, and documentation. © 2015 by the American College of Nurse-Midwives.

  1. Fetal organ dosimetry for the Techa River and Ozyorsk offspring cohorts. Pt. 1. A Urals-based series of fetal computational phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Maynard, Matthew R.; Bolch, Wesley E. [University of Florida, Advanced Laboratory for Radiation Dosimetry Studies (ALRADS), J. Crayton Pruitt Family Department of Biomedical Engineering, Gainesville, FL (United States); Shagina, Natalia B.; Tolstykh, Evgenia I.; Degteva, Marina O. [Urals Research Center for Radiation Medicine, Chelyabinsk (Russian Federation); Fell, Tim P. [Public Health England, Centre for Radiation, Chemical and Environmental Health, Didcot, Chilton, Oxon (United Kingdom)

    2015-03-15

    The European Union's SOLO (Epidemiological Studies of Exposed Southern Urals Populations) project aims to improve understanding of cancer risks associated with chronic in utero radiation exposure. A comprehensive series of hybrid computational fetal phantoms was previously developed at the University of Florida in order to provide the SOLO project with the capability of computationally simulating and quantifying radiation exposures to individual fetal bones and soft tissue organs. To improve harmonization between the SOLO fetal biokinetic models and the computational phantoms, a subset of those phantoms was systematically modified to create a novel series of phantoms matching anatomical data representing Russian fetal biometry in the Southern Urals. Using previously established modeling techniques, eight computational Urals-based phantoms aged 8, 12, 18, 22, 26, 30, 34, and 38 weeks post-conception were constructed to match appropriate age-dependent femur lengths, biparietal diameters, individual bone masses and whole-body masses. Bone and soft tissue organ mass differences between the common ages of the subset of UF phantom series and the Urals-based phantom series illustrated the need for improved understanding of fetal bone densities as a critical parameter of computational phantom development. In anticipation for SOLO radiation dosimetry studies involving the developing fetus and pregnant female, the completed phantom series was successfully converted to a cuboidal voxel format easily interpreted by radiation transport software. (orig.)

  2. Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts

    International Nuclear Information System (INIS)

    Bonel, H.; Frei, K.A.; Raio, L.; Meyer-Wittkopf, M.; Remonda, L.; Wiest, R.

    2008-01-01

    The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 ± 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 ± 0.58 vs. 3.65 ± 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 ± 7.27 to 19.83 ± 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement. (orig.)

  3. Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts.

    Science.gov (United States)

    Bonel, H; Frei, K A; Raio, L; Meyer-Wittkopf, M; Remonda, L; Wiest, R

    2008-04-01

    The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 +/- 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 +/- 0.58 vs. 3.65 +/- 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 +/- 7.27 to 19.83 +/- 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement.

  4. Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Bonel, H. [University Hospital Berne-Inselspital, Freiburgstrasse, Institute of Diagnostic, Interventional and Pediatric Radiology, Bern (Switzerland); Frei, K.A.; Raio, L.; Meyer-Wittkopf, M. [University of Berne, Women' s' Hospital, Bern (Switzerland); Remonda, L.; Wiest, R. [University of Berne, Institute of Diagnostic and Interventional Neuroradiology (DIN), Inselspital, Bern (Switzerland)

    2008-04-15

    The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 {+-} 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 {+-} 0.58 vs. 3.65 {+-} 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 {+-} 7.27 to 19.83 {+-} 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement. (orig.)

  5. Human fetal anatomy: MR imaging.

    Science.gov (United States)

    Weinreb, J C; Lowe, T; Cohen, J M; Kutler, M

    1985-12-01

    Twenty-four pregnant women carrying 26 fetuses (two sets of twins) were imaged with magnetic resonance (MR) imaging at 0.35 T following sonographic evaluation. Each study was retrospectively evaluated to determine which of 33 normal fetal structures were visible on the images and which imaging parameters were most useful for depicting fetal anatomy. Fetal motion degraded fetal images in all but two cases, both with oligohydramnios and in the third trimester of gestation. Nevertheless, many fetal structures were identifiable, particularly in the third trimester. Visualization of fetal anatomy improved with intravenous maternal sedation in five cases. Relatively T1-weighted images occasionally offered the advantage of less image degradation owing to fetal motion and improved contrast between different fetal structures. More T2 weighting was believed to be advantageous in one case for outlining the fetal head and in one case for delineation of the brain. In many cases, structures were similarly identifiable (though with different signal intensities) regardless of the parameters selected. The authors conclude that MR imaging of many fetal structures is currently unsatisfactory and is probably of limited value, particularly in the first and second trimesters. However, the relative frequency and detail with which the fetal head and liver can be depicted indicate that these may be areas for further investigation, and the potential utility of imaging fetal fat warrants further investigation.

  6. Fetal MSCs

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Derived from extra embryonic tissues (amniotic fluid, placenta, cord blood, Wharton's Jelly) and fetal tissues (aborted fetuses). Derived from extra embryonic tissues (amniotic fluid, placenta, cord blood, Wharton's Jelly) and fetal tissues (aborted fetuses). In comparison ...

  7. Fetal abdominal magnetic resonance imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2006-01-01

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages

  8. Fetal abdominal magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    This review deals with the in vivo magnetic resonance imaging (MRI) appearance of the human fetal abdomen. Imaging findings are correlated with current knowledge of human fetal anatomy and physiology, which are crucial to understand and interpret fetal abdominal MRI scans. As fetal MRI covers a period of more than 20 weeks, which is characterized not only by organ growth, but also by changes and maturation of organ function, a different MR appearance of the fetal abdomen results. This not only applies to the fetal intestines, but also to the fetal liver, spleen, and adrenal glands. Choosing the appropriate sequences, various aspects of age-related and organ-specific function can be visualized with fetal MRI, as these are mirrored by changes in signal intensities. Knowledge of normal development is essential to delineate normal from pathological findings in the respective developmental stages.

  9. Fetal tachycardia : diagnosis and treatment

    NARCIS (Netherlands)

    Oudijk, Martijn Alexander

    2003-01-01

    Part I: Fetal tachyarrhythmias Diagnosis Fetal tachycardia is a serious condition warranting specialized evaluation. In chapter 2, methods of diagnosis of fetal tachycardia are described, including doppler and M-mode echocardiography and fetal magnetocardiography. The study presented in chapter 3

  10. Fetal short time variation during labor: a non-invasive alternative to fetal scalp pH measurements?

    Science.gov (United States)

    Schiermeier, Sven; Reinhard, Joscha; Hatzmann, Hendrike; Zimmermann, Ralf C; Westhof, Gregor

    2009-01-01

    To determine whether short time variation (STV) of fetal heart beat correlates with scalp pH measurements during labor. From 1279 deliveries, 197 women had at least one fetal scalp pH measurement. Using the CTG-Player, STVs were calculated from the electronically saved cardiotocography (CTG) traces and related to the fetal scalp pH measurements. There was no correlation between STV and fetal scalp pH measurements (r=-0.0592). Fetal STV is an important parameter with high sensitivity for antenatal fetal acidosis. This study shows that STV calculations do not correlate with fetal scalp pH measurements during labor, hence are not helpful in identifying fetal acidosis.

  11. Impact of fetal echocardiography

    International Nuclear Information System (INIS)

    Simpson, John M

    2009-01-01

    Prenatal diagnosis of congenital heart disease is now well established for a wide range of cardiac anomalies. Diagnosis of congenital heart disease during fetal life not only identifies the cardiac lesion but may also lead to detection of associated abnormalities. This information allows a detailed discussion of the prognosis with parents. For continuing pregnancies, appropriate preparation can be made to optimize the postnatal outcome. Reduced morbidity and mortality, following antenatal diagnosis, has been reported for coarctation of the aorta, hypoplastic left heart syndrome, and transposition of the great arteries. With regard to screening policy, most affected fetuses are in the “low risk” population, emphasizing the importance of appropriate training for those who undertake such obstetric anomaly scans. As a minimum, the four chamber view of the fetal heart should be incorporated into midtrimester anomaly scans, and where feasible, views of the outflow tracts should also be included, to increase the diagnostic yield. Newer screening techniques, such as measurement of nuchal translucency, may contribute to identification of fetuses at high risk for congenital heart disease and prompt referral for detailed cardiac assessment

  12. The relationship between maternal and fetal vitamin D, insulin resistance, and fetal growth.

    LENUS (Irish Health Repository)

    Walsh, Jennifer M

    2013-05-01

    Evidence for a role of vitamin D in maintaining normal glucose homeostasis is inconclusive. We sought to clarify the relationship between maternal and fetal insulin resistance and vitamin D status. This is a prospective cohort study of 60 caucasian pregnant women. Concentrations of 25-hydroxyvitamin D (25-OHD), glucose, insulin, and leptin were measured in early pregnancy and at 28 weeks. Ultrasound at 34 weeks assessed fetal anthropometry including abdominal wall width, a marker of fetal adiposity. At delivery birth weight was recorded and fetal 25-OHD, glucose, C-peptide, and leptin measured in cord blood. Insulin resistance was calculated using the Homeostasis Model Assessment (HOMA) equation. We found that those with lower 25-OHD in early pregnancy had higher HOMA indices at 28 weeks, (r = -.32, P = .02). No significant relationship existed between maternal or fetal leptin and 25-OHD, or between maternal or fetal 25-OHD and fetal anthropometry or birth weight. The incidence of vitamin D deficiency was high at each time point (15%-45%). These findings lend support to routine antenatal supplementation with vitamin D in at risk populations.

  13. Characterization of the fetal blood transcriptome and proteome in maternal anti-fetal rejection: evidence of a distinct and novel type of human fetal systemic inflammatory response.

    Science.gov (United States)

    Lee, Joonho; Romero, Roberto; Chaiworapongsa, Tinnakorn; Dong, Zhong; Tarca, Adi L; Xu, Yi; Chiang, Po Jen; Kusanovic, Juan Pedro; Hassan, Sonia S; Yeo, Lami; Yoon, Bo Hyun; Than, Nandor Gabor; Kim, Chong Jai

    2013-10-01

    The human fetus is able to mount a systemic inflammatory response when exposed to microorganisms. This stereotypic response has been termed the 'fetal inflammatory response syndrome' (FIRS), defined as an elevation of fetal plasma interleukin-6 (IL-6). FIRS is frequently observed in patients whose preterm deliveries are associated with intra-amniotic infection, acute inflammatory lesions of the placenta, and a high rate of neonatal morbidity. Recently, a novel form of fetal systemic inflammation, characterized by an elevation of fetal plasma CXCL10, has been identified in patients with placental lesions consistent with 'maternal anti-fetal rejection'. These lesions include chronic chorioamnionitis, plasma cell deciduitis, and villitis of unknown etiology. In addition, positivity for human leukocyte antigen (HLA) panel-reactive antibodies (PRA) in maternal sera can also be used to increase the index of suspicion for maternal anti-fetal rejection. The purpose of this study was to determine (i) the frequency of pathologic lesions consistent with maternal anti-fetal rejection in term and spontaneous preterm births; (ii) the fetal serum concentration of CXCL10 in patients with and without evidence of maternal anti-fetal rejection; and (iii) the fetal blood transcriptome and proteome in cases with a fetal inflammatory response associated with maternal anti-fetal rejection. Maternal and fetal sera were obtained from normal term (n = 150) and spontaneous preterm births (n = 150). A fetal inflammatory response associated with maternal anti-fetal rejection was diagnosed when the patients met two or more of the following criteria: (i) presence of chronic placental inflammation; (ii) ≥80% of maternal HLA class I PRA positivity; and (iii) fetal serum CXCL10 concentration >75th percentile. Maternal HLA PRA was analyzed by flow cytometry. The concentrations of fetal CXCL10 and IL-6 were determined by ELISA. Transcriptome analysis was undertaken after the extraction of total RNA

  14. Fetal cerebral imaging - ultrasound vs. MRI: an update.

    Science.gov (United States)

    Blondiaux, Eléonore; Garel, Catherine

    2013-11-01

    The purpose of this article is to analyze the advantages and limitations of prenatal ultrasonography (US) and magnetic resonance imaging (MRI) in the evaluation of the fetal brain. These imaging modalities should not be seen as competitive but rather as complementary. There are wide variations in the world regarding screening policies, technology, skills, and legislation about termination of pregnancy, and these variations markedly impact on the way of using prenatal imaging. According to the contribution expected from each technique and to local working conditions, one should choose the most appropriate imaging modality on a case-by-case basis. The advantages and limitations of US and MRI in the setting of fetal brain imaging are displayed. Different anatomical regions (midline, ventricles, subependymal area, cerebral parenchyma, pericerebral space, posterior fossa) and pathological conditions are analyzed and illustrated in order to compare the respective contribution of each technique. An accurate prenatal diagnosis of cerebral abnormalities is of utmost importance for prenatal counseling.

  15. Fetal Echocardiography and Indications

    Directory of Open Access Journals (Sweden)

    Melih Atahan Güven

    2008-09-01

    Full Text Available Congenital heart diseases are encountered in 0.8% of live births and are among the most frequently diagnosed malformations. At least half of these anomalies end up with death or require surgical interventions and are responsible for 30% of the perinatal mortality. Fetal echocardiography is the sum of knowledge, skill and orientation rather than knowing the embryologic details of the fetal heart. The purpose of fetal echocardiography is to document the presence of normal fetal cardiac anatomy and rhythm in high risk group and to define the anomaly and arrhythmia if present. A certain sequence should be followed during the evaluation of fetal heart. Sequential segmental analysis (SSA and basic definition terminology made it possible to determine a lot of complex cardiac anomalies during prenatal period. By the end of 1970’s, Shinebourne started using sequential segmental analysis for fetal cardiac evaluation and today, prenatal diagnosis of congenital heart disease is possible without any confusion. In this manner, whole fetal heart can be evaluated as the relation of three segments (atria, ventricles and the great arteries with each other, irrelevant of complexity of a possible cardiac anomaly. Presence of increased nuchal thickness during early gestation and abnormal four-chamber-view during ultrasonography by the obstetrician presents a clear indication for fetal echocardiography,however, one should keep in mind that 80-90% of the babies born with a congenital heart disease do not have a familial or maternal risk factor. In addition, it should be remembered that expectant mothers with diabetes mellitus pose an indication for fetal echocardiography.

  16. Value of amniocentesis versus fetal tissue for cytogenetic analysis in cases of fetal demise.

    Science.gov (United States)

    Bryant Borders, Ann E; Greenberg, Jessica; Plaga, Stacey; Shepard-Hinton, Megan; Yates, Carin; Elias, Sherman; Shulman, Lee P

    2009-01-01

    Use of fetal tissue for cytogenetic analysis in cases of second- and third-trimester fetal demise frequently results in unacceptably high failure rates. We reviewed our ongoing use of amniocentesis prior to uterine evacuation to determine if this provided a better source of cells for cytogenetic analysis. We compared cytogenetic results using fetal tissues obtained following uterine evacuation to our ongoing use of amniotic fluid cell obtained by transabdominal amniocentesis prior to uterine evacuation from 2003 to 2008. In 49 of the 63 cases evaluated by fetal tissue biopsies performed after uterine evacuation, a karyotypic analysis was obtained (77.8%). Among the 38 cases evaluated by amniocentesis, an amniotic fluid sample and fetal cytogenetic results were obtained in all 38 (100%) cases. Our findings indicate that amniocentesis is a more reliable source of cytogenetic information than fetal tissue in cases of second- and third-trimester fetal demise.

  17. Fast, free-breathing, in vivo fetal imaging using time-resolved 3D MRI technique: preliminary results

    OpenAIRE

    Liu, Jing; Glenn, Orit A.; Xu, Duan

    2014-01-01

    Fetal MR imaging is very challenging due to the movement of fetus and the breathing motion of the mother. Current clinical protocols involve quick 2D scouting scans to determine scan plane and often several attempts to reorient the scan plane when the fetus moves. This makes acquisition of fetal MR images clinically challenging and results in long scan times in order to obtain images that are of diagnostic quality. Compared to 2D imaging, 3D imaging of the fetus has many advantages such as hi...

  18. Fetal body weight and the development of the control of the cardiovascular system in fetal sheep.

    Science.gov (United States)

    Frasch, M G; Müller, T; Wicher, C; Weiss, C; Löhle, M; Schwab, K; Schubert, H; Nathanielsz, P W; Witte, O W; Schwab, M

    2007-03-15

    Reduced birth weight predisposes to cardiovascular diseases in later life. We examined in fetal sheep at 0.76 (n = 18) and 0.87 (n = 17) gestation whether spontaneously occurring variations in fetal weight affect maturation of autonomic control of cardiovascular function. Fetal weights at both gestational ages were grouped statistically in low (LW) and normal weights (NW) (P fetal sheep not constituting a major malnutritive condition. Mean fetal blood pressure (FBP) of all fetuses was negatively correlated to fetal weight at 0.76 but not 0.87 gestation (P fetal heart rate depended on fetal weight (P fetal weight within the normal weight span is accompanied by a different trajectory of development of sympathetic blood pressure and vagal heart rate control. This may contribute to the development of elevated blood pressure in later life. Examination of the underlying mechanisms and consequences may contribute to the understanding of programming of cardiovascular diseases.

  19. FAST (Four chamber view And Swing Technique) Echo: a Novel and Simple Algorithm to Visualize Standard Fetal Echocardiographic Planes

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto; Jodicke, Cristiano; Oggè, Giovanna; Lee, Wesley; Kusanovic, Juan Pedro; Vaisbuch, Edi; Hassan, Sonia S.

    2010-01-01

    Objective To describe a novel and simple algorithm (FAST Echo: Four chamber view And Swing Technique) to visualize standard diagnostic planes of fetal echocardiography from dataset volumes obtained with spatiotemporal image correlation (STIC) and applying a new display technology (OmniView). Methods We developed an algorithm to image standard fetal echocardiographic planes by drawing four dissecting lines through the longitudinal view of the ductal arch contained in a STIC volume dataset. Three of the lines are locked to provide simultaneous visualization of targeted planes, and the fourth line (unlocked) “swings” through the ductal arch image (“swing technique”), providing an infinite number of cardiac planes in sequence. Each line generated the following plane(s): 1) Line 1: three-vessels and trachea view; 2) Line 2: five-chamber view and long axis view of the aorta (obtained by rotation of the five-chamber view on the y-axis); 3) Line 3: four-chamber view; and 4) “Swing” line: three-vessels and trachea view, five-chamber view and/or long axis view of the aorta, four-chamber view, and stomach. The algorithm was then tested in 50 normal hearts (15.3 – 40 weeks of gestation) and visualization rates for cardiac diagnostic planes were calculated. To determine if the algorithm could identify planes that departed from the normal images, we tested the algorithm in 5 cases with proven congenital heart defects. Results In normal cases, the FAST Echo algorithm (3 locked lines and rotation of the five-chamber view on the y-axis) was able to generate the intended planes (longitudinal view of the ductal arch, pulmonary artery, three-vessels and trachea view, five-chamber view, long axis view of the aorta, four-chamber view): 1) individually in 100% of cases [except for the three-vessel and trachea view, which was seen in 98% (49/50)]; and 2) simultaneously in 98% (49/50). The “swing technique” was able to generate the three-vessels and trachea view, five

  20. Screening for fetal growth restriction using fetal biometry combined with maternal biomarkers.

    Science.gov (United States)

    Gaccioli, Francesca; Aye, Irving L M H; Sovio, Ulla; Charnock-Jones, D Stephen; Smith, Gordon C S

    2018-02-01

    Fetal growth restriction is a major determinant of perinatal morbidity and mortality. Screening for fetal growth restriction is a key element of prenatal care but it is recognized to be problematic. Screening using clinical risk assessment and targeting ultrasound to high-risk women is the standard of care in the United States and United Kingdom, but the approach is known to have low sensitivity. Systematic reviews of randomized controlled trials do not demonstrate any benefit from universal ultrasound screening for fetal growth restriction in the third trimester, but the evidence base is not strong. Implementation of universal ultrasound screening in low-risk women in France failed to reduce the risk of complications among small-for-gestational-age infants but did appear to cause iatrogenic harm to false positives. One strategy to making progress is to improve screening by developing more sensitive and specific tests with the key goal of differentiating between healthy small fetuses and those that are small through fetal growth restriction. As abnormal placentation is thought to be the major cause of fetal growth restriction, one approach is to combine fetal biometry with an indicator of placental dysfunction. In the past, these indicators were generally ultrasonic measurements, such as Doppler flow velocimetry of the uteroplacental circulation. However, another promising approach is to combine ultrasonic suspicion of small-for-gestational-age infant with a blood test indicating placental dysfunction. Thus far, much of the research on maternal serum biomarkers for fetal growth restriction has involved the secondary analysis of tests performed for other indications, such as fetal aneuploidies. An exemplar of this is pregnancy-associated plasma protein A. This blood test is performed primarily to assess the risk of Down syndrome, but women with low first-trimester levels are now serially scanned in later pregnancy due to associations with placental causes of

  1. Clinical significance of perceptible fetal motion.

    Science.gov (United States)

    Rayburn, W F

    1980-09-15

    The monitoring of fetal activity during the last trimester of pregnancy has been proposed to be useful in assessing fetal welfare. The maternal perception of fetal activity was tested among 82 patients using real-time ultrasonography. All perceived fetal movements were visualized on the scanner and involved motion of the lower limbs. Conversely, 82% of all visualized motions of fetal limbs were perceived by the patients. All combined motions of fetal trunk with limbs were preceived by the patients and described as strong movements, whereas clusters of isolated, weak motions of the fetal limbs were less accurately perceived (56% accuracy). The number of fetal movements perceived during the 15-minute test period was significantly (p fetal motion was present (44 of 45 cases) than when it was absent (five of 10 cases). These findings reveal that perceived fetal motion is: (1) reliable; (2) related to the strength of lower limb motion; (3) increased with ruptured amniotic membranes; and (4) reassuring if considered to be active.

  2. A radiographic study of the human fetal spine

    International Nuclear Information System (INIS)

    Bagnall, K.M.; Harris, P.F.; Jones, P.R.M.

    1979-01-01

    Regression equations are presented which describe the growth in length of the various regions of the vertebral column in the human fetus. From 8 weeks on the thoracic is always the longest region and the sacral the shortest, while the lumbar region is longer than the cervical. From the regression equations predictions of fetal vertebral length can be made from fetal age: this should be useful in obstetric practice when diagnostic ultrasound techniques are being employed for the diagnosis of growth disorders and skeletal abnormalities. A different development pattern emerges when average 'vertebral units' for each region are compared. The lumbar vertebrae are always the largest with the thoracic, cervical and sacral vertebrae being progressively smaller. (author)

  3. Differential diagnosis between fetal extrarenal pelvis and obstructive uropathy on fetal ultrasonogram

    Energy Technology Data Exchange (ETDEWEB)

    Han, Byoung Hee; Cho, Jeong Yeon; Cho, Byung Jae; Lee, Kyung Sang [Samsung Cheil Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2003-03-15

    To establish the standard guideline for differentiating the extrarenal pelvis from obstructive uropathy on fetal ultrasonogram (US) to avoid unnecessary postnatal follow-up and other additional examinations. From July 2000 to July 2001, Thirty-four kidneys with hydronephrosis diagnosed on fetal ultrasonogram performed during the third trimester of pregnancy were included in this study. Hydronephrosis was defined as the pelvic anteroposterior (AP) diameter being 4 mm or greater before 33 weeks of gestation while 7 mm or greater at or after 33 weeks of gestation. The size of the renal pelvis was measured at intrarenal, intra-extrarenal junctional and extrarenal portions in every kidney on the transverse view of the fetal renal hiluin. Postnatally, all neonates underwent renal ultrasonogram 2 to 8 days after birth, and renal pelvic diameters were measured using the same method as the fetal US in 28 kidneys. We then compared the extrarenal-intrarenal ratio (E/I ratio) of pelvic diameter between fetal and neoatal kidneys. We presumed that the extrarenal pelvis in fetal US was the pelvis showing the normal intrarenal pelvic diameter accompanied by the most dilated exrtarenal pelvic diameter. Follow-up ultrasonograms were measured using the same method as the fetal US in 28 kidneys. We then compared the extrarenal intrarenal ratio (E/I ratio) of pelvic diameter between fetal and neonatal kidneys. We presumed that the extrarenal pelvis on fetal US was the pelvis showing the normal intrarenal pelvic diameter accompanied by the most dilated extrarenal pelvic diameter. Follow-up ultrasonograms were performed in 12 of 17 neonates who had the maximal diameter at extrarenal portion on fetal ultrasonogram. VCUG and IVU were taken in 2 patients with a persistent dilatation of the renal pelvis on follow-up ultrasonograms. On fetal US, 17/34 kidneys showed the extrarenal portion with the most dilatation while in 12/34 kidneys, the intra-extra renal junction portion was the most

  4. Differential diagnosis between fetal extrarenal pelvis and obstructive uropathy on fetal ultrasonogram

    International Nuclear Information System (INIS)

    Han, Byoung Hee; Cho, Jeong Yeon; Cho, Byung Jae; Lee, Kyung Sang

    2003-01-01

    To establish the standard guideline for differentiating the extrarenal pelvis from obstructive uropathy on fetal ultrasonogram (US) to avoid unnecessary postnatal follow-up and other additional examinations. From July 2000 to July 2001, Thirty-four kidneys with hydronephrosis diagnosed on fetal ultrasonogram performed during the third trimester of pregnancy were included in this study. Hydronephrosis was defined as the pelvic anteroposterior (AP) diameter being 4 mm or greater before 33 weeks of gestation while 7 mm or greater at or after 33 weeks of gestation. The size of the renal pelvis was measured at intrarenal, intra-extrarenal junctional and extrarenal portions in every kidney on the transverse view of the fetal renal hiluin. Postnatally, all neonates underwent renal ultrasonogram 2 to 8 days after birth, and renal pelvic diameters were measured using the same method as the fetal US in 28 kidneys. We then compared the extrarenal-intrarenal ratio (E/I ratio) of pelvic diameter between fetal and neoatal kidneys. We presumed that the extrarenal pelvis in fetal US was the pelvis showing the normal intrarenal pelvic diameter accompanied by the most dilated exrtarenal pelvic diameter. Follow-up ultrasonograms were measured using the same method as the fetal US in 28 kidneys. We then compared the extrarenal intrarenal ratio (E/I ratio) of pelvic diameter between fetal and neonatal kidneys. We presumed that the extrarenal pelvis on fetal US was the pelvis showing the normal intrarenal pelvic diameter accompanied by the most dilated extrarenal pelvic diameter. Follow-up ultrasonograms were performed in 12 of 17 neonates who had the maximal diameter at extrarenal portion on fetal ultrasonogram. VCUG and IVU were taken in 2 patients with a persistent dilatation of the renal pelvis on follow-up ultrasonograms. On fetal US, 17/34 kidneys showed the extrarenal portion with the most dilatation while in 12/34 kidneys, the intra-extra renal junction portion was the most

  5. Mapping fetal brain development in utero using magnetic resonance imaging: the Big Bang of brain mapping.

    Science.gov (United States)

    Studholme, Colin

    2011-08-15

    The development of tools to construct and investigate probabilistic maps of the adult human brain from magnetic resonance imaging (MRI) has led to advances in both basic neuroscience and clinical diagnosis. These tools are increasingly being applied to brain development in adolescence and childhood, and even to neonatal and premature neonatal imaging. Even earlier in development, parallel advances in clinical fetal MRI have led to its growing use as a tool in challenging medical conditions. This has motivated new engineering developments encompassing optimal fast MRI scans and techniques derived from computer vision, the combination of which allows full 3D imaging of the moving fetal brain in utero without sedation. These promise to provide a new and unprecedented window into early human brain growth. This article reviews the developments that have led us to this point, examines the current state of the art in the fields of fast fetal imaging and motion correction, and describes the tools to analyze dynamically changing fetal brain structure. New methods to deal with developmental tissue segmentation and the construction of spatiotemporal atlases are examined, together with techniques to map fetal brain growth patterns.

  6. Feasibility of using auto Mod-MPI system, a novel technique for automated measurement of fetal modified myocardial performance index.

    Science.gov (United States)

    Lee, M-Y; Won, H-S; Jeon, E-J; Yoon, H C; Choi, J Y; Hong, S J; Kim, M-J

    2014-06-01

    To evaluate the reproducibility of measurement of the fetal left modified myocardial performance index (Mod-MPI) determined using a novel automated system. This was a prospective study of 116 ultrasound examinations from 110 normal singleton pregnancies at 12 + 1 to 37 + 1 weeks' gestation. Two experienced operators each measured the left Mod-MPI twice manually and twice automatically using the Auto Mod-MPI system. Intra- and interoperator reproducibility were assessed using intraclass correlation coefficients (ICCs) and the manual and automated measurements obtained by the more experienced operator were compared using Bland-Altman plots and ICCs. Both operators successfully measured the left Mod-MPI in all cases using the Auto Mod-MPI system. For both operators, intraoperator reproducibility was higher when performing automated measurements (ICC = 0.967 and 0.962 for Operators 1 and 2, respectively) than when performing manual measurements (ICC = 0.857 and 0.856 for Operators 1 and 2, respectively). Interoperator agreement was also better for automated than for manual measurements (ICC = 0.930 vs 0.723, respectively). There was good agreement between the automated and manual values measured by the more experienced operator. The Auto Mod-MPI system is a reliable technique for measuring fetal left Mod-MPI and demonstrates excellent reproducibility. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  7. Fetal QRS extraction from abdominal recordings via model-based signal processing and intelligent signal merging

    International Nuclear Information System (INIS)

    Haghpanahi, Masoumeh; Borkholder, David A

    2014-01-01

    Noninvasive fetal ECG (fECG) monitoring has potential applications in diagnosing congenital heart diseases in a timely manner and assisting clinicians to make more appropriate decisions during labor. However, despite advances in signal processing and machine learning techniques, the analysis of fECG signals has still remained in its preliminary stages. In this work, we describe an algorithm to automatically locate QRS complexes in noninvasive fECG signals obtained from a set of four electrodes placed on the mother’s abdomen. The algorithm is based on an iterative decomposition of the maternal and fetal subspaces and filtering of the maternal ECG (mECG) components from the fECG recordings. Once the maternal components are removed, a novel merging technique is applied to merge the signals and detect the fetal QRS (fQRS) complexes. The algorithm was trained and tested on the fECG datasets provided by the PhysioNet/CinC challenge 2013. The final results indicate that the algorithm is able to detect fetal peaks for a variety of signals with different morphologies and strength levels encountered in clinical practice. (paper)

  8. Fetal Alcohol Syndrome and Fetal Alcohol Effects in Child Development.

    Science.gov (United States)

    Pancratz, Diane R.

    This literature review defines Fetal Alcohol Syndrome (FAS) and Fetal Alcohol Effects (FAE) and considers their causes, diagnoses, prevalence, and educational ramifications. Effects of alcohol during each of the trimesters of pregnancy are summarized. Specific diagnostic characteristics of FAS are listed: (1) growth deficiency, (2) a…

  9. Fetal scalp blood sampling during labor

    DEFF Research Database (Denmark)

    Chandraharan, Edwin; Wiberg, Nana

    2014-01-01

    Fetal cardiotocography is characterized by low specificity; therefore, in an attempt to ensure fetal well-being, fetal scalp blood sampling has been recommended by most obstetric societies in the case of a non-reassuring cardiotocography. The scientific agreement on the evidence for using fetal...... scalp blood sampling to decrease the rate of operative delivery for fetal distress is ambiguous. Based on the same studies, a Cochrane review states that fetal scalp blood sampling increases the rate of instrumental delivery while decreasing neonatal acidosis, whereas the National Institute of Health...... and Clinical Excellence guideline considers that fetal scalp blood sampling decreases instrumental delivery without differences in other outcome variables. The fetal scalp is supplied by vessels outside the skull below the level of the cranial vault, which is likely to be compressed during contractions...

  10. Intrapartum fetal monitoring by ST-analysis of the fetal ECG

    NARCIS (Netherlands)

    Westerhuis, M.E.M.H.

    2010-01-01

    Objective Intrapartum fetal monitoring aims to identify fetuses at risk for neonatal and long-term injury due to asphyxia. To serve this purpose, cardiotocography (CTG) combined with ST-analysis of the fetal electrocardiogram (ECG), which is a relatively new method, may be used. The main aim of this

  11. Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation.

    Science.gov (United States)

    Gonçalves, Luís F; Lee, Wesley; Chaiworapongsa, Tinnakorn; Espinoza, Jimmy; Schoen, Mary Lou; Falkensammer, Peter; Treadwell, Marjorie; Romero, Roberto

    2003-12-01

    This study was undertaken to describe a new technique for the examination of the fetal heart using four-dimensional ultrasonography with spatiotemporal image correlation (STIC). Volume data sets of the fetal heart were acquired with a new cardiac gating technique (STIC), which uses automated transverse and longitudinal sweeps of the anterior chest wall. These volumes were obtained from 69 fetuses: 35 normal, 16 with congenital anomalies not affecting the cardiovascular system, and 18 with cardiac abnormalities. Dynamic multiplanar slicing and surface rendering of cardiac structures were performed. To illustrate the STIC technique, two representative volumes from a normal fetus were compared with volumes obtained from fetuses with the following congenital heart anomalies: atrioventricular septal defect, tricuspid stenosis, tricuspid atresia, and interrupted inferior vena cava with abnormal venous drainage. Volume datasets obtained with a transverse sweep were utilized to demonstrate the cardiac chambers, moderator band, interatrial and interventricular septae, atrioventricular valves, pulmonary veins, and outflow tracts. With the use of a reference dot to navigate the four-chamber view, intracardiac structures could be simultaneously studied in three orthogonal planes. The same volume dataset was used for surface rendering of the atrioventricular valves. The aortic and ductal arches were best visualized when the original plane of acquisition was sagittal. Volumes could be interactively manipulated to simultaneously visualize both outflow tracts, in addition to the aortic and ductal arches. Novel views of specific structures were generated. For example, the location and extent of a ventricular septal defect was imaged in a sagittal view of the interventricular septum. Furthermore, surface-rendered images of the atrioventricular valves were employed to distinguish between normal and pathologic conditions. Representative video clips were posted on the Journal's Web

  12. MR imaging methods for assessing fetal brain development.

    Science.gov (United States)

    Rutherford, Mary; Jiang, Shuzhou; Allsop, Joanna; Perkins, Lucinda; Srinivasan, Latha; Hayat, Tayyib; Kumar, Sailesh; Hajnal, Jo

    2008-05-01

    Fetal magnetic resonance imaging provides an ideal tool for investigating growth and development of the brain in vivo. Current imaging methods have been hampered by fetal motion but recent advances in image acquisition can produce high signal to noise, high resolution 3-dimensional datasets suitable for objective quantification by state of the art post acquisition computer programs. Continuing development of imaging techniques will allow a unique insight into the developing brain, more specifically process of cell migration, axonal pathway formation, and cortical maturation. Accurate quantification of these developmental processes in the normal fetus will allow us to identify subtle deviations from normal during the second and third trimester of pregnancy either in the compromised fetus or in infants born prematurely.

  13. Fetal short time variation during labor: a non-invasive alternative to fetal scalp pH measurements?

    OpenAIRE

    Schiermeier, Sven; Reinhard, Joscha; Hatzmann, Hendrike; Zimmermann, Ralf C.; Westhof, Gregor

    2009-01-01

    Objective: To determine whether short time variation (STV) of fetal heart beat correlates with scalp pH measurements during labor. Patients and methods: From 1279 deliveries, 197 women had at least one fetal scalp pH measurement. Using the CTG-Player®, STVs were calculated from the electronically saved cardiotocography (CTG) traces and related to the fetal scalp pH measurements. Results: There was no correlation between STV and fetal scalp pH measurements (r=−0.0592). Conclusions: Fetal ST...

  14. Real-Time Automatic Fetal Brain Extraction in Fetal MRI by Deep Learning

    OpenAIRE

    Salehi, Seyed Sadegh Mohseni; Hashemi, Seyed Raein; Velasco-Annis, Clemente; Ouaalam, Abdelhakim; Estroff, Judy A.; Erdogmus, Deniz; Warfield, Simon K.; Gholipour, Ali

    2017-01-01

    Brain segmentation is a fundamental first step in neuroimage analysis. In the case of fetal MRI, it is particularly challenging and important due to the arbitrary orientation of the fetus, organs that surround the fetal head, and intermittent fetal motion. Several promising methods have been proposed but are limited in their performance in challenging cases and in real-time segmentation. We aimed to develop a fully automatic segmentation method that independently segments sections of the feta...

  15. Fetal blood drawing.

    Science.gov (United States)

    Hobbins, J C; Mahoney, M J

    1975-07-19

    A small sample of fetal blood suitable for studies of haemoglobin synthesis was obtained from a placental vessel under endoscopic visualisation in 23 of 26 patients in whom the procedure was attempted prior to second-trimester abortion. Fetal blood loss, calculated in 23 cases, was between 0-2 ml. and 2-5 ml., and fetal blood-volume depletion varied from 0-5% to 15%. No short-term ill-effects were demonstrated in mother or fetus in any of 16 patients in whom the injection of aborti-facient was postponed for between 16 and 24 hours after the procedure.

  16. Interventions for intrauterine resuscitation in suspected fetal distress during term labor : A systematic review

    NARCIS (Netherlands)

    Bullens, L.; van Runnard Heimel, P.J.; van der Hout-van der Jagt, M.B.; Oei, G.

    IMPORTANCE: Intrauterine resuscitation techniques during term labor are commonly used in daily clinical practice. Evidence, however, to support the beneficial effect of intrauterine resuscitation techniques on fetal distress during labor is limited and sometimes contradictory. In contrast, some of

  17. Patient and fetal dose in diagnostic x-rays and radiotherapy in Bangkok, Thailand

    International Nuclear Information System (INIS)

    Pataramontree, J.; Wangsuphachart, S.; Apaiphonlacharn, J.; Chaichan, P.; Sompradit, S.; Suteerakul, K.; Thamwerawong, W.

    2001-01-01

    In 1999 the multicenter study of the patient surface dose was conducted at Department of Radiology of Chulalongkorn Hospital, another two university hospitals and a hospital in the suburb. Adult female patients were selected to measure the entrance skin dose and accumulated dose by using the thermoluminescent dosimeters and the kerma area product meter, respectively. The fetal doses were calculated by Monte Carlo method using the computer program written by Le Heron J.C. The average fetal doses were studied for each diagnostic radiographic procedure. The fetus got 0.29, 0.35, 2.63 mGy when its mother had radiography of pelvis, lumbosacral spine, excretory urography respectively. The estimated fetal doses for barium meal, barium enema and renal angiography were 1.47, 33.5 and 3.68 mGy, respectively. The fetal dose varies so much about 2-3 times of the average fetal dose due to equipment and techniques. The study of lower abdomen by computed tomography gave 48.4 mGy on average to a fetus. The scattered dose level outside radiotherapeutic x-rays at fetal position in Random Phantom depends on the primary beam area rather than the energy of radiation. If the threshold dose for fetal malformation is 0.1 Gy, the minimum safety distance for him is 22 cm from beam edges for the tumor dose of 60 Gy. (author)

  18. Fetal and neonatal thyrotoxicosis

    Science.gov (United States)

    Batra, Chandar Mohan

    2013-01-01

    Fetal thyrotoxicosis is a rare disease occurring in 1 out of 70 pregnancies with Grave's disease or in 1 out of 4000-50,000 deliveries. The mortality is 12-20%, usually from heart failure, but other complications are tracheal compression, infections and thrombocytopenia. It results from transfer of thyroid stimulating immunoglobulins from mother to fetus through the placenta. This transplacental transfer begins around 20th week of pregnancy and reaches its maximum by 30th week. These autoantibodies bind to the fetal thyroid stimulating hormone (TSH) receptors and increase the secretion of the thyroid hormones. The mother has an active autoimmune thyroid disease or has been treated for it in the past. She may be absolutely euthyroid due to past treatment by drugs, surgery or radioiodine ablation, but still have active TSH receptor stimulating autoantibodies, which can cause fetal thyrotoxicosis. The other features of this disease are fetal tachycardia, fetal goiter and history of spontaneous abortions and findings of goiter, ascites, craniosyntosis, fetal growth retardation, maceration and hydrops at fetal autopsy. If untreated, this disease can result in intrauterine death. The treatment for this disease consists of giving carbimazole to the mother, which is transferred through the placenta to the fetus. The dose of carbimazole is titrated with the fetal heart rate. If the mother becomes hypothyroid due to carbimazole, thyroxine is added taking advantage of the fact that very little of thyroxine is transferred across the placenta. Neonatal thyrotoxicosis patients are very sick and require emergency treatment. The goal of the treatment is to normalize thyroid functions as quickly as possible, to avoid iatrogenic hypothyroidism while providing management and supportive therapy for the infant's specific signs and symptoms. PMID:24251220

  19. Fetal MRI of pathological brain development; Fetale MRT der pathologischen Hirnentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, P.C. [Medizinische Universitaet Wien (Austria). Arbeitsgruppe Integrative Morphologie, Zentrum fuer Anatomie und Zellbiologie; Prayer, D. [Medizinische Universitaet Wien (Austria). Klinik fuer Radiodiagnostik

    2006-02-15

    Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.) [German] Aufgrund des hervorragenden Gewebekontrastes, der hohen raeumlichen Aufloesung und multiplanaren Moeglichkeiten erlaubt die fetale Magnetresonanztomographie (MRT) eine detaillierte Darstellung fetaler Hirnpathologien. Eine pathologische Hirnentwicklung kann sowohl auf Fehlbildungen als auch waehrend der Schwangerschaft erworbenen Stoerungen beruhen. Nachdem die weiteren Konsequenzen fuer die bestehende, aber auch fuer folgende Schwangerschaften zu einem grossen Teil von einer Differenzierung dieser Aetiologien abhaengig sein kann, ist ein Erkennen der jeweiligen Pathologie wesentlich. Die morphologische Praesentation erworbener und fehlbildungsbedingter Veraenderungen auf MR-Bildern ist u. U. sehr aehnlich. Besondere differenzialdiagnostische Probleme bereitet dabei das Vorliegen eines erweiterten Ventrikelsystems, das als Symptom unterschiedlichster Veraenderungen vorliegen kann. Anhand einer systematischen Darstellung mittels MR-erfassbarer morphologischer Details wird eine Anleitung gegeben, bei Bestehen dieses Leitsymptoms zu einer moeglichst genauen Diagnose zu kommen

  20. Antithyroid drug-induced fetal goitrous hypothyroidism

    DEFF Research Database (Denmark)

    Bliddal, Sofie; Rasmussen, Ase Krogh; Sundberg, Karin

    2011-01-01

    Maternal overtreatment with antithyroid drugs can induce fetal goitrous hypothyroidism. This condition can have a critical effect on pregnancy outcome, as well as on fetal growth and neurological development. The purpose of this Review is to clarify if and how fetal goitrous hypothyroidism can...... be prevented, and how to react when prevention has failed. Understanding the importance of pregnancy-related changes in maternal thyroid status when treating a pregnant woman is crucial to preventing fetal goitrous hypothyroidism. Maternal levels of free T(4) are the most consistent indication of maternal...... and fetal thyroid status. In patients with fetal goitrous hypothyroidism, intra-amniotic levothyroxine injections improve fetal outcome. The best way to avoid maternal overtreatment with antithyroid drugs is to monitor closely the maternal thyroid status, especially estimates of free T(4) levels....

  1. MR evaluation of fetal demise

    International Nuclear Information System (INIS)

    Victoria, Teresa; Chauvin, Nancy Anne; Johnson, Ann M.; Kramer, Sandra Sue; Epelman, Monica; Capilla, Elena

    2011-01-01

    Fetal demise is an uncommon event encountered at MR imaging. When it occurs, recognition by the interpreting radiologist is important to initiate appropriate patient management. To identify MR findings of fetal demise. Following IRB approval, a retrospective search of the radiology fetal MR database was conducted searching the words ''fetal demise'' and ''fetal death.'' Fetuses with obvious maceration or no sonographic confirmation of death were excluded. Eleven cases formed the study group. These were matched randomly to live fetuses of similar gestational age. Images were reviewed independently by three pediatric radiologists. The deceased fetus demonstrates decreased MR soft-tissue contrast and definition of tissue planes, including loss of gray-white matter differentiation in the brain. The signal within the cardiac chambers, when visible, is bright on HASTE sequences from the stagnant blood; the heart is small. Pleural effusions and decreased lung volumes may be seen. Interestingly, the fetal orbits lose their anatomical round shape and become smaller and more elliptical; a dark, irregular rim resembling a mask may be seen. Although fetal demise is uncommonly encountered at MR imaging, radiologists should be aware of such imaging findings so prompt management can be instituted. (orig.)

  2. 21 CFR 884.2900 - Fetal stethoscope.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal stethoscope. 884.2900 Section 884.2900 Food... Fetal stethoscope. (a) Identification. A fetal stethoscope is a device used for listening to fetal heart... conventional stethoscopes. (b) Classification. Class I (general controls). The device is exempt from the...

  3. Relações entre a saúde mental da gestante e o apego materno-fetal Relations between pregnant women's mental health and maternal-fetal attachment

    Directory of Open Access Journals (Sweden)

    Patrícia Alvarenga

    2012-12-01

    Full Text Available O estudo investigou as relações entre variáveis sociodemográficas, saúde mental da gestante e o apego materno-fetal no terceiro trimestre de gestação. Participaram do estudo 261 gestantes selecionadas através de amostragem por acessibilidade em quatro maternidades públicas. As gestantes responderam individualmente uma ficha de dados sociodemográficos, a Escala de Apego Materno-Fetal e o SRQ-20. A análise de regressão revelou que o número de filhos (4% e a saúde mental materna (4,2% explicaram parte da variância no apego materno-fetal. A escolaridade da mãe e do pai não esteve associada a essa variável. O modelo de regressão múltipla considerando os quatro fatores analisados, explicou 8,2% da variância nos escores de apego materno-fetal. Discutem-se as implicações dessas variáveis na formação do vínculo da mãe com o bebê durante a gestação.This study investigated the relations among sociodemographic variables, pregnant women mental health, and maternal-fetal attachment in the third trimester of pregnancy. Participants were 261 pregnant women recruited from public maternity wards using a convenience sampling technique. Each pregnant woman completed a sociodemographic data form, the Maternal-Fetal Attachment Scale, and the SRQ-20. Regression analysis revealed that the number of children (4% and mothers' mental health (4.2% accounted for part of the variance in maternal-fetal attachment scores. Father's and mother's schooling was not associated with this variable. Taking the four analyzed factors into account, a multiple regression model accounted for 8.2% of the variance in the maternal-fetal attachment scores. The implications of these variables for mother-infant bonding during pregnancy are discussed.

  4. Characterization of fetal growth by repeated ultrasound measurements in the wild guinea pig (Cavia aperea).

    Science.gov (United States)

    Schumann, K; Guenther, A; Göritz, F; Jewgenow, K

    2014-08-01

    Fetal growth during pregnancy has previously been studied in the domesticated guinea pig (Cavia aperea f. porcellus) after dissecting pregnant females, but there are no studies describing the fetal growth in their wild progenitor, the wild guinea pig (C aperea). In this study, 50 pregnancies of wild guinea pig sows were investigated using modern ultrasound technique. The two most common fetal growth parameters (biparietal diameter [BPD] and crown-rump-length [CRL]) and uterine position were measured. Data revealed similar fetal growth patterns in the wild guinea pig and domesticated guinea pig in the investigated gestation period, although they differ in reproductive milestones such as gestation length (average duration of pregnancy 68 days), average birth weight, and litter mass. In this study, pregnancy lasted on average 60.2 days with a variance of less than a day (0.96 days). The measured fetal growth parameters are strongly correlated with each (R = 0.91; P guinea pig. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Value of fetal skeletal radiographs in the diagnosis of fetal death

    International Nuclear Information System (INIS)

    Bourliere-Najean, B.; Russel, A.S.; Petit, P.; Devred, P.; Panuel, M.; Piercecchi-Marti, M.D.; Fredouille, C.; Sigaudy, S.; Philip, N.

    2003-01-01

    The aim of this study was to assess the value of fetal skeletal radiographs in determining the etiology of fetal death. A total of 1193 post-mortem fetal skeletal radiographs were analysed. Fetuses were classified into one of three groups (group I: abnormality diagnosed during pregnancy; group II: maternal pathology; group III: spontaneous abortion of pregnancy, IIIa before 26 weeks of gestation (WG), IIIb after 26 weeks of gestation). Face, supine and lateral skeletal views were performed. Skeletal abnormalities were detected in 33.9% of the fetuses, including 22.7% with minor abnormalities (abnormal rib number, no nasal bone ossification, amesophalangia or P2 hypoplasia of the fifth digit) and 14.5% with major abnormalities (other skeletal abnormalities). Among the fetuses with major abnormalities, 98.8% came from group I, 2.9% came from group II, 2.3% came from group IIIa and none came from group IIIb. Fetal skeletal radiographs are not useful in fetuses arising from spontaneous abortion of pregnancy without abnormality on ultrasound screening, abnormality clinical examination or in fetuses with prenatal diagnosis of chromosomal abnormality. This practice is valuable only if there is a multidisciplinary team, with all the participants (pathologists, radiologists, geneticists) knowledgeable about fetal pathology. In the absence of this multidisciplinary approach, it is easier to X-ray all fetuses to avoid misdiagnosis and the important consequences for genetic counselling. (orig.)

  6. Value of fetal skeletal radiographs in the diagnosis of fetal death

    Energy Technology Data Exchange (ETDEWEB)

    Bourliere-Najean, B.; Russel, A.S.; Petit, P.; Devred, P. [Department of Pediatric Radiology, CHU Timone, 264 rue St. Pierre, 13385 Marseille cedex 5 (France); Panuel, M. [Department of Radiology, Hopital Nord, chemin Bourrelys, 13915 Marseille cedex 20 (France); Piercecchi-Marti, M.D.; Fredouille, C. [Department of Pathology, CHU Timone, 264 rue St. Pierre, 13385 Marseille cedex 5 (France); Sigaudy, S.; Philip, N. [Department of Genetics, CHU Timone, 264 rue St. Pierre, 13385 Marseille cedex 5 (France)

    2003-05-01

    The aim of this study was to assess the value of fetal skeletal radiographs in determining the etiology of fetal death. A total of 1193 post-mortem fetal skeletal radiographs were analysed. Fetuses were classified into one of three groups (group I: abnormality diagnosed during pregnancy; group II: maternal pathology; group III: spontaneous abortion of pregnancy, IIIa before 26 weeks of gestation (WG), IIIb after 26 weeks of gestation). Face, supine and lateral skeletal views were performed. Skeletal abnormalities were detected in 33.9% of the fetuses, including 22.7% with minor abnormalities (abnormal rib number, no nasal bone ossification, amesophalangia or P2 hypoplasia of the fifth digit) and 14.5% with major abnormalities (other skeletal abnormalities). Among the fetuses with major abnormalities, 98.8% came from group I, 2.9% came from group II, 2.3% came from group IIIa and none came from group IIIb. Fetal skeletal radiographs are not useful in fetuses arising from spontaneous abortion of pregnancy without abnormality on ultrasound screening, abnormality clinical examination or in fetuses with prenatal diagnosis of chromosomal abnormality. This practice is valuable only if there is a multidisciplinary team, with all the participants (pathologists, radiologists, geneticists) knowledgeable about fetal pathology. In the absence of this multidisciplinary approach, it is easier to X-ray all fetuses to avoid misdiagnosis and the important consequences for genetic counselling. (orig.)

  7. Epigenetic regulation and fetal programming.

    Science.gov (United States)

    Gicquel, Christine; El-Osta, Assam; Le Bouc, Yves

    2008-02-01

    Fetal programming encompasses the role of developmental plasticity in response to environmental and nutritional signals during early life and its potential adverse consequences (risk of cardiovascular, metabolic and behavioural diseases) in later life. The first studies in this field highlighted an association between poor fetal growth and chronic adult diseases. However, environmental signals during early life may lead to adverse long-term effects independently of obvious effects on fetal growth. Adverse long-term effects reflect a mismatch between early (fetal and neonatal) environmental conditions and the conditions that the individual will confront later in life. The mechanisms underlying this risk remain unclear. However, experimental data in rodents and recent observations in humans suggest that epigenetic changes in regulatory genes and growth-related genes play a significant role in fetal programming. Improvements in our understanding of the biochemical and molecular mechanisms at play in fetal programming would make it possible to identify biomarkers for detecting infants at high risk of adult-onset diseases. Such improvements should also lead to the development of preventive and therapeutic strategies.

  8. Fetal pancreatic beta-cell function in pregnancies complicated by maternal diabetes mellitus: relationship to fetal acidemia and macrosomia.

    Science.gov (United States)

    Salvesen, D R; Brudenell, J M; Proudler, A J; Crook, D; Nicolaides, K H

    1993-05-01

    Our purpose was to investigate the relationship between fetal pancreatic beta-cell function and fetal acidemia and macrosomia in pregnancies complicated by maternal diabetes mellitus. A cross-sectional study at the Harris Birthright Research Centre for Fetal Medicine, London, was performed. In 32 pregnancies complicated by maternal diabetes mellitus cordocentesis was performed at 36 to 39 weeks' gestation for the measurement of umbilical venous blood pH, PO2, PCO2, lactate, and glucose concentration; plasma insulin immunoreactivity; and insulin/glucose ratio. A reference range for plasma insulin and insulin/glucose ratio was constructed by studying fetal blood samples from 80 women who did not have diabetes mellitus. Mean umbilical venous blood pH was significantly lower and plasma insulin immunoreactivity and insulin/glucose ratio were significantly higher than the appropriate normal mean for gestation. There were significant associations between (1) maternal and fetal blood glucose concentrations (r = 0.95, p < 0.0001), (2) fetal blood glucose and plasma insulin immunoreactivity (r = 0.57, p < 0.01), (3) fetal plasma insulin immunoreactivity and blood pH (r = -0.39, p < 0.05), and (4) fetal insulin/glucose ratio and degree of macrosomia (r = 0.76, p < 0.0001). Fetal pancreatic beta-cell hyperplasia is implicated in the pathogenesis of both fetal acidemia and macrosomia.

  9. Fetal magnetic resonance imaging of thoracic and abdominal malformations; Fetale Magnetresonanztomographie thorakaler und abdomineller Malformationen

    Energy Technology Data Exchange (ETDEWEB)

    Woitek, R.; Asenbaum, U.; Furtner, J.; Prayer, D. [Medizinische Universitaet Wien, Abteilung fuer Neuroradiologie und Muskuloskelettale Radiologie, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Brugger, P.C. [Medizinische Universitaet Wien, Zentrum fuer Anatomie und Zellbiologie, Wien (Austria)

    2013-02-15

    Diagnosis and differential diagnosis of fetal thoracic and abdominal malformations. Ultrasound and magnetic resonance imaging (MRI). In cases of suspected pathologies based on fetal ultrasound MRI can be used for more detailed examinations and can be of assistance in the differential diagnostic process. Improved imaging of anatomical structures and of the composition of different tissues by the use of different MRI sequences. Fetal MRI has become a part of clinical routine in thoracic and abdominal malformations and is the basis for scientific research in this field. In cases of thoracic or abdominal malformations fetal MRI provides important information additional to ultrasound to improve diagnostic accuracy, prognostic evaluation and surgical planning. (orig.) [German] Diagnose und Differenzialdiagnose fetaler thorakaler und abdomineller Malformationen. Ultraschall, MRT. MRT zur weiteren Abklaerung und genaueren Differenzierung bei vielen im Ultraschall gestellten Verdachtsdiagnosen. Verbesserte anatomische Darstellung mittels MRT und Darstellung unterschiedlicher Gewebezusammensetzung mittels verschiedener MR-Sequenzen. Die fetale MRT ist bei der angegebenen Fragestellung in die klinische Routine eingegangen und liefert weiterhin die Basis fuer wissenschaftliche Untersuchungen in diesem Bereich. Die fetale MRT liefert beim Vorliegen thorakaler oder abdomineller Malformationen komplementaer zum Ultraschall wichtige Zusatzinformationen, um die diagnostische Genauigkeit zu erhoehen, die Prognoseabschaetzung zu verbessern und ggf. eine bessere chirurgische Planung zu ermoeglichen. (orig.)

  10. Frecuencia cardiaca y movimientos fetales posterior a la administracion de betametasona para maduración pulmonar fetal

    Directory of Open Access Journals (Sweden)

    Yolima Ruiz Lopez

    2013-05-01

    Full Text Available El objetivo de la investigación fue demostrar las modificaciones de la frecuencia cardiaca y los movimientos fetales producidas por la administración de betametasona para maduración pulmonar fetal. Se realizó una investigación de tipo explicativa, prospectiva y longitudinal con un diseño cuasi-experimental y una muestra no probabilística de 106 gestantes entre 24 y 34 semanas, con diagnóstico de amenaza de parto pretérmino tratadas con betametasona (12 mg intramuscular cada 24 horas por dos dosis que acudieron al Hospital Central “Dr. Urquinaona”. Se evaluaron los movimientos fetales y frecuencia cardiaca materna y fetal. No se encontraron diferencias significativas en la frecuencia cardiaca materna comparado con los valores iniciales (p = ns. Se observó que el valor inicial de la frecuencia cardiaca fetal fue de 135,1±9,7 latidos por minuto para aumentar luego a 137,2±8,9 latidos por minuto (p = ns para presentar un nuevo aumento hasta (142,9±9,9 latidos por minuto que fue significativo comparado con los valores iniciales (p < 0,05. Se observó una disminución significativa de movimientos fetales medidos en 30 minutos después de la primera inyección (23,1±6,0 movimientos comparado con 14,8±7,0 movimientos, para aumentar después de la segunda inyección pero aun presentando valores significativamente más bajos comparado con los valores iniciales (20,0 ±6,7 movimientos; p < 0,05. Se concluye que la administración de betametasona para maduración pulmonar fetal produce incremento significativo en la frecuencia cardiaca y reducción marcada de los movimientos fetales. Abstract Fetal heart rate and movements after betamethasone administration for fetal lung maturity The objective of research was to demonstrate fetal heart rate and movements modifications by the use of betamethasone for fetal lung maturity. An explicative, prospective and longitudinal research was done with a quasi-experimental design and a non

  11. Fetal dose reduction in head and neck radiotherapy of a pregnant woman

    International Nuclear Information System (INIS)

    Moeckli, R.; Pache, G.; Valley, J.F.; Ozsahin, M.; Mirimanoff, R.O.; Azria, D.

    2004-01-01

    Background and purpose: a pregnant woman was referred for post-operative radiotherapy of a malignant schwannoma in the head and neck region. A best-treatment plan was devised in order to minimize the fetal dose. Material and methods: the fetal dose resulting from radiological examinations was determined according to international protocols, that resulting from radiotherapy was calculated according to recommendation 36 of the American Association of Physicists in Medicine (AAPM) Task Group. Pre-treatment dosimetry was performed with an anthropomorphic phantom. Several alternative treatment plans were evaluated. The use of a multileaf collimator (MLC) and a virtual wedge (VW) was compared to cerrobend blocks (CB) and physical wedge (PW). In-vivo dosimetry was performed using a vaginal probe containing thermoluminescent dosimeters (TLD). Results: the total fetal dose resulting from diagnostic and radiotherapy procedures was estimated to be 36 mGy. The technique based on MLC and VW was elected for patient treatment. Measurements for this configuration resulted in a fetal dose reduction of 82%. The shielding of the patient's abdomen further reduced the fetal dose by 42%. Conclusion: the use of VW and MLC for the treatment of a pregnant woman is highly recommended. Each case should be individually studied with pre-treatment and in-vivo dosimetry. (orig.)

  12. Chromosome 11-linked determinant controls fetal globin expression and the fetal-to-adult globin switch

    International Nuclear Information System (INIS)

    Melis, M.; Demopulos, G.; Najfeld, V.; Zhang, J.W.; Brice, M.; Papayannopoulou, T.; Stamatoyannopoulos, G.

    1987-01-01

    Hybrids formed by fusing mouse erythroleukemia (MEL) cells with human fetal erythroid cells produce human fetal globin, but they switch to adult globin production as culture time advances. To obtain information on the chromosomal assignment of the elements that control γ-to-β switching, the authors analyzed the chromosomal composition of hybrids producing exclusively or predominantly human fetal globin and hybrids producing only adult human globin. No human chromosome was consistently present in hybrids expressing fetal globin and consistently absent in hybrids expressing adult globin. Subcloning experiments demonstrated identical chromosomal compositions in subclones displaying the fetal globin program and those that had switched to expression of the adult globin program. These data indicate that retention of only one human chromosome -- i.e., chromosome 11 -- is sufficient for expression of human fetal globin and the subsequent γ-to-β switch. The results suggest that the γ-to-β switch is controlled either cis to the β-globin locus of by a trans-acting mechanism, the genes of which reside on human chromosome 11

  13. Simultaneous use of intrapartum fetal pulse oximetry and amnioinfusion in meconium stained amniotic fluid.

    Science.gov (United States)

    Halvax, László; Szabó, István; Vizer, Miklós; Csermely, Tamás; Ertl, Tibor

    2002-09-10

    Fetal pulse oximetry is a minimally invasive, simple technique which continuously helps to reflect in utero well-being. The presence of meconium in the amniotic fluid may be a clinical sign of fetal hypoxaemia. Amnioinfusion has a beneficial effect on the incidence of meconium aspiration syndrome (MAS), and the presence of meconium below the level of the vocal cords. We studied the impact of amnioinfusion combined with fetal pulse oximetry on the incidence of meconium aspiration syndrome and operative delivery. The retrospective analysis revealed that the presence of meconium below the level of vocal cords was significantly reduced. The frequency of cesarean section is decreased, however, it did not reach statistical significance. Fetal pulse oximetry may be used in combination with amnioinfusion and cardiotocography (CTG) to reduce the risk of meconium aspiration syndrome and the number of instrumental deliveries and improve perinatal outcome. Copyright 2002 Elsevier Science Ireland Ltd.

  14. Fetal Echocardiography/Your Unborn Baby's Heart

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Fetal Echocardiography / Your Unborn Baby's Heart Updated:Oct 6,2016 ... Your Risk • Symptoms & Diagnosis Introduction Common Tests Fetal Echocardiography/Your Unborn Baby's Heart - Fetal Echocardiogram Test - Detection ...

  15. Fetal growth velocity and body proportion in the assessment of growth.

    Science.gov (United States)

    Hiersch, Liran; Melamed, Nir

    2018-02-01

    Fetal growth restriction implies failure of a fetus to meet its growth potential and is associated with increased perinatal mortality and morbidity. Therefore, antenatal detection of fetal growth restriction is of major importance in an attempt to deliver improved clinical outcomes. The most commonly used approach towards screening for fetal growth restriction is by means of sonographic fetal weight estimation, to detect fetuses small for gestational age, defined by an estimated fetal weight <10th percentile for gestational age. However, the predictive accuracy of this approach is limited both by suboptimal detection rate (as it may overlook non-small-for-gestational-age growth-restricted fetuses) and by a high false-positive rate (as most small-for-gestational-age fetuses are not growth restricted). Here, we review 2 strategies that may improve the diagnostic accuracy of sonographic fetal biometry for fetal growth restriction. The first strategy involves serial ultrasound evaluations of fetal biometry. The information obtained through these serial assessments can be interpreted using several different approaches including fetal growth velocity, conditional percentiles, projection-based methods, and individualized growth assessment that can be viewed as mathematical techniques to quantify any decrease in estimated fetal weight percentile, a phenomenon that many care providers assess and monitor routinely in a qualitative manner. This strategy appears promising in high-risk pregnancies where it seems to improve the detection of growth-restricted fetuses at increased risk of adverse perinatal outcomes and, at the same time, decrease the risk of falsely diagnosing healthy constitutionally small-for-gestational-age fetuses as growth restricted. Further studies are needed to determine the utility of this strategy in low-risk pregnancies as well as to optimize its performance by determining the optimal timing and interval between exams. The second strategy refers to the

  16. Diagnóstico prenatal no invasivo: Ácidos nucleicos de origen fetal en sangre materna Non invasive prenatal diagnosis: Fetal nucleic acid analysis in maternal blood

    Directory of Open Access Journals (Sweden)

    Carla Sesarini

    2010-12-01

    decade, the presence of cell-free fetal DNA in maternal blood has been identified. These fetal DNA fragments would derive from the placenta and are not detected after delivery, making them a source of fetal material for carrying out diagnosis techniques using maternal blood. However, the vast majority of cell free DNA in maternal circulation is of maternal origin, with the fetal component contributing from 3% to 6% and rising towards term. Available methodologies do not allow separation of fetal from maternal cell free DNA, so current applications have been focused on the analysis of genes not present in the mother, such as Y chromosome sequences, or RHD gene in RhD-negative women, or paternal or de novo mutations. Also, the detection of cell-free fetal RNA in maternal blood offers the possibility of obtaining information regarding genetic expression profiles of embrionic tissues, and using genes expressed only at the feto-placental unit, controls for the presence of fetal material could be established, regardless of maternal genetic tissue. The present article describes the evidences regarding the passage of fetal nucleic acids to maternal circulation, its current prenatal diagnosis application and possible future perspectives.

  17. Maternal hemodynamics, fetal biometry and Dopplers in pregnancies followed up for suspected fetal growth restriction.

    Science.gov (United States)

    Roberts, Llinos A; Ling, Hua Zen; Poon, Liona; Nicolaides, Kypros H; Kametas, Nikos A

    2018-04-01

    To assess whether in a cohort of patients with small for gestational age (SGA) foetuses with estimated fetal weight ≤10 th percentile, maternal hemodynamics, fetal biometry and Dopplers at presentation, can predict the subsequent development of abnormal fetal Dopplers or delivery with birthweight Cheetah), mean arterial pressure, fetal biometry, umbilical artery (UA), middle cerebral artery (MCA) and uterine artery (UT) pulsatility index (PI) and the deepest vertical pool (DVP) of amniotic fluid. Z-scores of these variables were calculated based on reported reference ranges and the values were compared between those with evidence of abnormal fetal Dopplers at presentation (group 1), those that developed abnormal Dopplers in subsequent visits (group 2) and those who did not develop abnormal Dopplers throughout pregnancy (group 3). Abnormal fetal Dopplers were defined as UAPI >95 th percentile, or MCA PI <5 th percentile. Differences in measured variables at presentation were also compared between pregnancies delivering a baby with birthweight <3 rd and ≥3 rd percentile. Multivariate logistic regression analysis was used to determine significant predictors of birthweight <3 rd percentile and evolution from normal fetal Dopplers to abnormal fetal Dopplers in groups 2 and 3. In the study population 14 (16%) cases were in group 1, 19 (22%) in group 2 and 53 (62%) in group 3. The birthweight was <3 rd percentile in 39 (45%) cases and ≥3 rd percentile in 47 (55%). In the study groups, compared to normal populations, there was decreased cardiac output and stroke volume and increased peripheral vascular resistance and mean arterial pressure (MAP) and the deviations from normal were most marked in group 1. Pregnancies with a birthweight <3 rd , compared to those ≥3 rd percentile, had higher deviations from normal in fetal biometry, maternal cardiac output, stroke volume, heart rate and peripheral vascular resistance and UT-PI. Multivariate logistic regression

  18. Fetal RHD Genotyping Using Real-Time Polymerase Chain Reaction Analysis of Cell-Free Fetal DNA in Pregnancy of RhD Negative Women in South of Iran

    Directory of Open Access Journals (Sweden)

    Leili Moezzi

    2016-05-01

    Full Text Available Background: Maternal-fetal RhD antigen incompatibility causes approximately 50% of clinically significant alloimmunization cases. The routine use of prophylactic anti-D immunoglobulin has dramatically reduced hemolytic disease of the fetus and newborn. Recently, fetal RHD genotyping in RhD negative pregnant women has been suggested for appropriate use of anti-D immunoglobulin antenatal prophylaxis and decrease unnecessary prenatal interventions. Materials and Methods: In this prospective cohort study, in order to develop a reliable and non-invasive method for fetal RHD genotyping, cell free fetal DNA (cffDNA was extracted from maternal plasma. Real-time quantitative polymerase chain reaction (qPCR for detection of RHD exons 7, 5, 10 and intron 4 was performed and the results were compared to the serological results of cord blood cells as the gold standard method. SRY gene and hypermethylated Ras-association domain family member 1 (RASSF1A gene were used to confirm the presence of fetal DNA in male and female fetuses, respectively. Results: Out of 48 fetuses between 8 and 32 weeks (wks of gestational age (GA, we correctly diagnosed 45 cases (93.75% of RHD positive fetuses and 2 cases (4.16% of the RHD negative one. Exon 7 was amplified in one sample, while three other RHD gene sequences were not detected; the sample was classified as inconclusive, and the RhD serology result after birth showed that the fetus was RhD-negative. Conclusion: Our results showed high accuracy of the qPCR method using cffDNA for fetal RHD genotyping and implicate on the efficiency of this technique to predict the competence of anti-D immunoglobulin administration.

  19. Digital atlas of fetal brain MRI.

    Science.gov (United States)

    Chapman, Teresa; Matesan, Manuela; Weinberger, Ed; Bulas, Dorothy I

    2010-02-01

    Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the atlas, written in C#, permits linked scrolling and resizing the images. Simultaneous comparison of varying gestational ages is permissible. Fetal brain images across gestational ages 18 to 37 weeks are provided as an interactive digital atlas and are available for free download from http://radiology.seattlechildrens.org/teaching/fetal_brain . Improved interpretation of fetal brain abnormalities can be facilitated by the use of digital atlas cataloging of the normal changes throughout fetal development. Here we provide a description of the atlas and a discussion of normal fetal brain development.

  20. Maternal protein-energy malnutrition during early pregnancy in sheep impacts the fetal ornithine cycle to reduce fetal kidney microvascular development.

    Science.gov (United States)

    Dunford, Louise J; Sinclair, Kevin D; Kwong, Wing Y; Sturrock, Craig; Clifford, Bethan L; Giles, Tom C; Gardner, David S

    2014-11-01

    This paper identifies a common nutritional pathway relating maternal through to fetal protein-energy malnutrition (PEM) and compromised fetal kidney development. Thirty-one twin-bearing sheep were fed either a control (n=15) or low-protein diet (n=16, 17 vs. 8.7 g crude protein/MJ metabolizable energy) from d 0 to 65 gestation (term, ∼ 145 d). Effects on the maternal and fetal nutritional environment were characterized by sampling blood and amniotic fluid. Kidney development was characterized by histology, immunohistochemistry, vascular corrosion casts, and molecular biology. PEM had little measureable effect on maternal and fetal macronutrient balance (glucose, total protein, total amino acids, and lactate were unaffected) or on fetal growth. PEM decreased maternal and fetal urea concentration, which blunted fetal ornithine availability and affected fetal hepatic polyamine production. For the first time in a large animal model, we associated these nutritional effects with reduced micro- but not macrovascular development in the fetal kidney. Maternal PEM specifically impacts the fetal ornithine cycle, affecting cellular polyamine metabolism and microvascular development of the fetal kidney, effects that likely underpin programming of kidney development and function by a maternal low protein diet. © FASEB.

  1. Accounting for Fetal Origins

    DEFF Research Database (Denmark)

    Dalgaard, Carl-Johan Lars; Hansen, Casper Worm; Strulik, Holger

    2017-01-01

    The Fetal Origins hypothesis has received considerable empirical support, both within epidemiology and economics. The present study compares the ability of two rival theoretical frameworks in accounting for the kind of path dependence implied by the Fetal Origins Hypothesis. We argue that while...

  2. The number of fetal cells in maternal blood is associated to exercise and fetal gender

    DEFF Research Database (Denmark)

    Schlütter, Jacob Mørup; Kirkegaard, Ida; Christensen, Connie Britta

    Introduction: We have established a robust method to specifically identify and isolate a placental fetal cell in maternal blood (fcmbs) at a gestational age of 12 weeks. The concentration of these cells, however, varies considerably among pregnant women (median 3 fcmbs/30 mL blood, range 0...... activity was obtained by a questionnaire and a structured interview. The number of fcmbs was assessed in 30 mL blood processed by a proprietary method developed in-house. Fetal cells in the blood, binding to fetal cell specific antibodies, were initially isolated by magnetic cell sorting. The fetal cells...... vs. 4, p=0.06) decreased the number of fcmbs, whereas coitus the evening before increased the number (4 vs. 3, p=0.11). Conclusion: The number of fcmbs is affected by normal activities. This should be taken into account when planning collection of fetal cells in connection for prenatal diagnosis...

  3. Fetal response to maternal hunger and satiation - novel finding from a qualitative descriptive study of maternal perception of fetal movements.

    Science.gov (United States)

    Bradford, Billie; Maude, Robyn

    2014-08-26

    Maternal perception of decreased fetal movements is a specific indicator of fetal compromise, notably in the context of poor fetal growth. There is currently no agreed numerical definition of decreased fetal movements, with the subjective perception of a decrease on the part of the mother being the most significant definition clinically. Both qualitative and quantitative aspects of fetal activity may be important in identifying the compromised fetus.Yet, how pregnant women perceive and describe fetal activity is under-investigated by qualitative means. The aim of this study was to explore normal fetal activity, through first-hand descriptive accounts by pregnant women. Using qualitative descriptive methodology, interviews were conducted with 19 low-risk women experiencing their first pregnancy, at two timepoints in their third trimester. Interview transcripts were later analysed using qualitative content analysis and patterns of fetal activity identified were then considered along-side the characteristics of the women and their birth outcomes. This paper focuses on a novel finding; the description by pregnant women of fetal behaviour indicative of hunger and satiation. Full findings will be presented in later papers. Most participants (74% 14 of 19) indicated mealtimes were a time of increased fetal activity. Eight participants provided detailed descriptions of increased activity around meals, with seven (37% 7 of 19) of these specifying increased fetal activity prior to meals or in the context of their own hunger. These movements were interpreted as a fetal demand for food often prompting the mother to eat. Interestingly, the women who described increased fetal activity in the context of hunger subsequently gave birth to smaller infants (mean difference 364 gm) than those who did not describe a fetal response to hunger. Food seeking behaviour may have a pre-birth origin. Maternal-fetal interaction around mealtimes could constitute an endocrine mediated

  4. Digital atlas of fetal brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chapman, Teresa; Weinberger, E. [Department of Radiology, Seattle Children' s Hospital, Seattle, WA (United States); Matesan, Manuela [University of Washington, Department of Radiology, Seattle, WA (United States); Bulas, Dorothy I. [Division of Diagnostic Imaging and Radiology, Children' s National Medical Center, Washington, DC (United States)

    2010-02-15

    Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the atlas, written in C, permits linked scrolling and resizing the images. Simultaneous comparison of varying gestational ages is permissible. Fetal brain images across gestational ages 18 to 37 weeks are provided as an interactive digital atlas and are available for free download. Improved interpretation of fetal brain abnormalities can be facilitated by the use of digital atlas cataloging of the normal changes throughout fetal development. Here we provide a description of the atlas and a discussion of normal fetal brain development. (orig.)

  5. Digital atlas of fetal brain MRI

    International Nuclear Information System (INIS)

    Chapman, Teresa; Weinberger, E.; Matesan, Manuela; Bulas, Dorothy I.

    2010-01-01

    Fetal MRI can be performed in the second and third trimesters. During this time, the fetal brain undergoes profound structural changes. Interpretation of appropriate development might require comparison with normal age-based models. Consultation of a hard-copy atlas is limited by the inability to compare multiple ages simultaneously. To provide images of normal fetal brains from weeks 18 through 37 in a digital format that can be reviewed interactively. This will facilitate recognition of abnormal brain development. T2-W images for the atlas were obtained from fetal MR studies of normal brains scanned for other indications from 2005 to 2007. Images were oriented in standard axial, coronal and sagittal projections, with laterality established by situs. Gestational age was determined by last menstrual period, earliest US measurements and sonogram performed on the same day as the MR. The software program used for viewing the atlas, written in C, permits linked scrolling and resizing the images. Simultaneous comparison of varying gestational ages is permissible. Fetal brain images across gestational ages 18 to 37 weeks are provided as an interactive digital atlas and are available for free download. Improved interpretation of fetal brain abnormalities can be facilitated by the use of digital atlas cataloging of the normal changes throughout fetal development. Here we provide a description of the atlas and a discussion of normal fetal brain development. (orig.)

  6. MRI of the fetal spine

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Erin M. [Departement of Radiology, Children' s Hospital of Philadelphia, PA (United States)

    2004-09-01

    Magnetic resonance imaging of the fetal spine is a vital complement to fetal sonographic examination. Assessing the wide spectrum of spinal dysraphism, as well as spinal neoplasia, allows for more correct prenatal diagnoses, patient care planning, and patient counselling. Proper appraisal of the value of experimental procedures, such as fetal myelomeningocoele repair, requires a high level of diagnostic accuracy for the selection and follow-up of appropriate candidates. (orig.)

  7. MRI of the fetal spine

    International Nuclear Information System (INIS)

    Simon, Erin M.

    2004-01-01

    Magnetic resonance imaging of the fetal spine is a vital complement to fetal sonographic examination. Assessing the wide spectrum of spinal dysraphism, as well as spinal neoplasia, allows for more correct prenatal diagnoses, patient care planning, and patient counselling. Proper appraisal of the value of experimental procedures, such as fetal myelomeningocoele repair, requires a high level of diagnostic accuracy for the selection and follow-up of appropriate candidates. (orig.)

  8. Thrombophilic disorders and fetal loss: a meta-analysis.

    Science.gov (United States)

    Rey, Evelyne; Kahn, Susan R; David, Michèle; Shrier, Ian

    2003-03-15

    Our aim was to assess the strength of the controversial association between thrombophilia and fetal loss, and to examine whether it varies according to the timing or definition of fetal loss. We searched Medline and Current Contents for articles published between 1975 and 2002 and their references with terms denoting recurrent fetal and non-recurrent fetal loss combined with various thrombophilic disorders. We included in our meta-analysis case-control, cohort, and cross-sectional studies published in English, the methodological quality of which was rated as moderate or strong. Pooled odds ratios (OR) with 95% CI were generated by random effects models with Cochrane Review Manager software. We included 31 studies. Factor V Leiden was associated with early (OR 2.01, 95% CI 1.13-3.58) and late (7.83, 2.83-21.67) recurrent fetal loss, and late non-recurrent fetal loss (3.26, 1.82-5.83). Exclusion of women with other pathologies that could explain fetal loss strengthened the association between Factor V Leiden and recurrent fetal loss. Activated protein C resistance was associated with early recurrent fetal loss (3.48, 1.58-7.69), and prothrombin G20210A mutation with early recurrent (2.56, 1.04-.29) and late non-recurrent (2.30, 1.09-4.87) fetal loss. Protein S deficiency was associated with recurrent fetal loss (14.72, 0.99-218.01) and late non-recurrent fetal loss (7.39, 1.28-42.63). Methylenetetrahydrofolate mutation, protein C, and antithrombin deficiencies were not significantly associated with fetal loss. The magnitude of the association between thrombophilia and fetal loss varies, according to type of fetal loss and type of thrombophilia.

  9. Extraction of the fetal ECG in noninvasive recordings by signal decompositions

    International Nuclear Information System (INIS)

    Christov, I; Simova, I; Abächerli, R

    2014-01-01

    No signal processing technique has been able to reliably deliver an undistorted fetal electrocardiographic (fECG) signal from electrodes placed on the maternal abdomen because of the low signal-to-noise ratio of the fECG recorded from the maternal body surface. As a result, this led to increased rates of Caesarean deliveries of healthy infants. In an attempt to solve the problem, Physionet/Computing in Cardiology announced the 2013 Challenge: noninvasive fetal ECG. We are suggesting a method for cancellation of the maternal ECG consisting of: maternal QRS detection, heart rate dependant P-QRS-T interval selection, location of the fiducial points inside this interval for best matching by cross correlation, superimposition of the intervals, calculation of the mean signal of the P-QRS-T interval, and sequential subtraction of the mean signal from the whole fECG recording. Three signal decomposition methods were further applied in order to enhance the fetal QRSs (fQRS): principal component analysis, root-mean-square and Hotelling’s T-squared. A combined lead of all decompositions was synthesized and fQRS detection was performed on it. The current research differs from the Challenge in that it uses three signal decomposition methods to enhance the fECG. The new results for 97 recordings of test set B are: 305.657 for Event 4: Fetal heart rate (FHR) and 23.062 for Event 5: Fetal RR interval (FRR). (paper)

  10. Validity of common ultrasound methods of fetal weight estimation in ...

    African Journals Online (AJOL)

    Fetal parametric measurements including BPD, FL,. AC, and HC were taken by a single observer with twelve years experience in obstetric sonography at the point of scanning and the time of scanning noted. All the four parameters (BPD, FL, AC, and HC) were measured using standard techniques. The BPD was measured ...

  11. The World Health Organization fetal growth charts: concept, findings, interpretation, and application.

    Science.gov (United States)

    Kiserud, Torvid; Benachi, Alexandra; Hecher, Kurt; Perez, Rogelio González; Carvalho, José; Piaggio, Gilda; Platt, Lawrence D

    2018-02-01

    Ultrasound biometry is an important clinical tool for the identification, monitoring, and management of fetal growth restriction and development of macrosomia. This is even truer in populations in which perinatal morbidity and mortality rates are high, which is a reason that much effort is put onto making the technique available everywhere, including low-income societies. Until recently, however, commonly used reference ranges were based on single populations largely from industrialized countries. Thus, the World Health Organization prioritized the establishment of fetal growth charts for international use. New fetal growth charts for common fetal measurements and estimated fetal weight were based on a longitudinal study of 1387 low-risk pregnant women from 10 countries (Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand) that provided 8203 sets of ultrasound measurements. The participants were characterized by median age 28 years, 58% nulliparous, normal body mass index, with no socioeconomic or nutritional constraints (median caloric intake, 1840 calories/day), and had the ability to attend the ultrasound sessions, thus essentially representing urban populations. Median gestational age at birth was 39 weeks, and birthweight was 3300 g, both with significant differences among countries. Quantile regression was used to establish the fetal growth charts, which also made it possible to demonstrate a number of features of fetal growth that previously were not well appreciated or unknown: (1) There was an asymmetric distribution of estimated fetal weight in the population. During early second trimester, the distribution was wider among fetuses 50th percentile. (2) Although fetal sex, maternal factors (height, weight, age, and parity), and country had significant influence on fetal weight (1-4.5% each), their effect was graded across the percentiles. For example, the positive effect of maternal height on fetal

  12. O6-methylguanine DNA methyltransferase in human fetal tissues: fetal and maternal factors

    International Nuclear Information System (INIS)

    D'Ambrosio, S.M.; Samuel, M.J.; Dutta-Choudhury, T.A.; Wani, A.A.

    1986-01-01

    O 6 -Methylguanine methyltransferase (O 6 -MT) was measured and compared in extracts of 7 human fetal tissues obtained from 21 different fetal specimens as a function of fetal age and race, and maternal smoking and drug usage. Activity was determined from the proteinase-K solubilized radioactivity transferred from the DNA to the O 6 -MT. S9 homogenates were incubated with a heat depurinated [ 3 H]-methylnitrosourea alkylated DNA. Liver exhibited the highest activity followed by kidney, lung, small intestine, large intestine, skin and brain. Each of the tissues exhibited a 3- to 5-fold level of interindividual variation of O 6 -MT. There did not appear to be any significant difference of O 6 -MT in the tissues obtained from mothers who smoked cigarettes during pregnancy. Also, fetal race and age did not appear to account for the level of variation of O 6 -MT. The fetal tissues obtained from an individual using phenobarbital and smoking exhibited 4-fold increases in O 6 -MT activity. The tissues obtained from another individual on kidney dialysis were 2- to 3-fold higher than the normal population. These data suggest that the variation in human O 6 -MT can not be explained by racial or smoking factors, but may be modulated by certain drugs

  13. Fetal MRI

    International Nuclear Information System (INIS)

    Prayer, D.; Brugger, P.C.

    2004-01-01

    New, ultrafast sequences have made it possible to obtain MR images of the fetus without maternal sedation or immobilization of the fetus itself. While fetal MRI began as an adjunct to ultrasound, it has now been shown that MRI can provide additional information that may change prognosis, the management of pregnancy, or the treatment of the newborn child. It is of particular value in the assessment of malformations of the central nervous system. The steady development and adaptation of MR-sequences to the needs of fetal imaging has led to new indications that can support prognostic and therapeutic decisions. (orig.)

  14. Fetal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, D.; Brugger, P.C. [University Hospital of Vienna (Austria). Division of Neuroradiology

    2004-07-01

    New, ultrafast sequences have made it possible to obtain MR images of the fetus without maternal sedation or immobilization of the fetus itself. While fetal MRI began as an adjunct to ultrasound, it has now been shown that MRI can provide additional information that may change prognosis, the management of pregnancy, or the treatment of the newborn child. It is of particular value in the assessment of malformations of the central nervous system. The steady development and adaptation of MR-sequences to the needs of fetal imaging has led to new indications that can support prognostic and therapeutic decisions. (orig.)

  15. Cadmium-induced fetal toxicity in the rat

    International Nuclear Information System (INIS)

    Levin, A.A.

    1980-01-01

    Cadmium, a heavy metal environment contaminant, induces fetal death and placental necrosis in the Wistar rat. This study investigated fetal, maternal, and placental responses to cadmium intoxication. Subcutaneous injection of CdCl 2 to dams on day 18 of pregnancy produced a high incidence of fetal death (75%) and placental necrosis. Death in the fetus was produced despite limited fetal accumulations of cadmium. Distribution studies using 109 Cd-labeled CdCl 2 demonstrated that less than 0.1% of the injected dose was associated with the fetus. To determine if fetuses were sensitive to these low levels of cadmium, direct injections of CdCl 2 into fetuses were performed in utero. Direct injections produced fetal accumulations 8-fold greater than those following maternal injections. The 8-fold greater fetal accumulations following direct injection were associated with only a 12% fetal mortality compared to the 75% mortality following maternal injections. The data indicated that the fetal toxicity of cadmium following maternal injections was not the result of direct effects of cadmium on the fetus. In conclusion, cadmium-induced fetal death was not the result of direct effects of cadmium on the fetus but may have been induced by placental cellular injury resulting from high accumulations of cadmium in the placenta. A vascular response to placental injury, leading to decreased utero-placental bood flow and cadmium-induced alterations in trophoblastic function, resulted in fetal death

  16. The "Fetal Reserve Index": Re-Engineering the Interpretation and Responses to Fetal Heart Rate Patterns.

    Science.gov (United States)

    Eden, Robert D; Evans, Mark I; Evans, Shara M; Schifrin, Barry S

    2018-01-01

    Electronic fetal monitoring (EFM) correlates poorly with neonatal outcome. We present a new metric: the "Fetal Reserve Index" (FRI), formally incorporating EFM with maternal, obstetrical, fetal risk factors, and excessive uterine activity for assessment of risk for cerebral palsy (CP). We performed a retrospective, case-control series of 50 term CP cases with apparent intrapartum neurological injury and 200 controls. All were deemed neurologically normal on admission. We compared the FRI against ACOG Category (I-III) system and long-term outcome parameters against ACOG monograph (NEACP) requirements for labor-induced fetal neurological injury. Abnormal FRI's identified 100% of CP cases and did so hours before injury. ACOG Category III identified only 44% and much later. Retrospective ACOG monograph criteria were found in at most 30% of intrapartum-acquired CP patients; only 27% had umbilical or neonatal pH <7.0. In this initial, retrospective trial, an abnormal FRI identified all cases of labor-related neurological injury more reliably and earlier than Category III, which may allow fetal therapy by intrauterine resuscitation. The combination of traditional EFM with maternal, obstetrical, and fetal risk factors creating the FRI performed much better as a screening test than EFM alone. Our quantified screening system needs further evaluation in prospective trials. © 2017 S. Karger AG, Basel.

  17. Minimal alteration in the ratio of circulatory fetal DNA to fetal corticotropin-releasing hormone mRNA level in preeclampsia.

    Science.gov (United States)

    Zhong, Xiao Yan; Holzgreve, Wolfgang; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Gupta, Anurag Kumar; Huppertz, Berthold; Hahn, Sinuhe

    2006-01-01

    We have recently observed that fetal DNA and fetal corticotropin-releasing hormone (CRH) mRNA are associated with in vitro generated syncytiotrophoblast-derived microparticles, and that the ratio of fetal DNA to mRNA (CRH) varied according to whether the particles were derived by predominantly apoptotic, apo-necrotic or necrotic pathways. Hence, we examined whether these ratios varied in maternal plasma samples taken from normotensive and preeclamptic pregnancies in vivo. Maternal plasma samples were collected from 18 cases with preeclampsia and 29 normotensive term controls. Circulatory fetal CRH mRNA and DNA levels were quantified by real-time PCR and RT-PCR. Circulatory fetal mRNA and fetal DNA levels were significantly elevated in the preeclampsia study group when compared to normotensive controls. Alterations in the fetal mRNA to DNA ratio between the study and control groups were minimal, even when stratified into early (34 weeks of gestation) onset preeclampsia. Our data suggest that although circulatory fetal DNA and mRNA levels are significantly elevated in preeclampsia, the ratios in maternal plasma are not dramatically altered. Copyright 2006 S. Karger AG, Basel.

  18. Prenatal sonographic measurement of the fetal thyroid gland

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Young Cheol; Kim, Young Hwa; Cho, Won Soo; Bae, Won Kyung; Kim, Il Young [Chunan Hospital, Soonchunhyang University College of Medicine, Chunan (Korea, Republic of)

    2001-03-15

    To investigate whether the fetal thyroid gland could be examined by prenatal ultrasonography and to established the normal range of fetal thyroid width according to the gestational age. The width of the fetal thyroid was determined by prenatal ultrasonography from 118 pregnant women. Three of the mothers had current or previous thyroid disease and the widths of the fetal thyroid were determined from 115 normal subjects. The width of the fetal thyroid was defined by a maximum transverse distance of the thyroid gland between two carotid arteries on transverse scan of the fetal neck. We analyzed the cause of non-measurable cases. The width of the fetal thyroid and Neo-TSH were compared in 19 subjects, including 3 subjects will current or previous thyroid disease. We could measure the fetal thyroid widths in 95 cases (80%). The fetal thyroid widths of mothers without current or previous thyroid disease was 0.9-2.36 cm,which showed linear correlation with gestational age (Y=0.0506 X + 0.0439, r{sup 2}=0.5661). Causes of non-measurable cases were neck flexion (65%), prone position (22%), and overlapped fetal neck by arm or shoulder (13%). Of the 19 neonates with Neo-TSH level, one case had a mother with a thyroid disease and showed increased width of the fetal and high Neo-TSH. The fetal thyroid was measured in 80% of prenatal ultrasonography and the width of the fetal thyroid showed linear correlated with gestational age. We assumed that the width of the thyroid could be useful for diagnosing fetal thyroid disorder when maternal thyroid disease exists.

  19. Prenatal sonographic measurement of the fetal thyroid gland

    International Nuclear Information System (INIS)

    Ahn, Young Cheol; Kim, Young Hwa; Cho, Won Soo; Bae, Won Kyung; Kim, Il Young

    2001-01-01

    To investigate whether the fetal thyroid gland could be examined by prenatal ultrasonography and to established the normal range of fetal thyroid width according to the gestational age. The width of the fetal thyroid was determined by prenatal ultrasonography from 118 pregnant women. Three of the mothers had current or previous thyroid disease and the widths of the fetal thyroid were determined from 115 normal subjects. The width of the fetal thyroid was defined by a maximum transverse distance of the thyroid gland between two carotid arteries on transverse scan of the fetal neck. We analyzed the cause of non-measurable cases. The width of the fetal thyroid and Neo-TSH were compared in 19 subjects, including 3 subjects will current or previous thyroid disease. We could measure the fetal thyroid widths in 95 cases (80%). The fetal thyroid widths of mothers without current or previous thyroid disease was 0.9-2.36 cm,which showed linear correlation with gestational age (Y=0.0506 X + 0.0439, r 2 =0.5661). Causes of non-measurable cases were neck flexion (65%), prone position (22%), and overlapped fetal neck by arm or shoulder (13%). Of the 19 neonates with Neo-TSH level, one case had a mother with a thyroid disease and showed increased width of the fetal and high Neo-TSH. The fetal thyroid was measured in 80% of prenatal ultrasonography and the width of the fetal thyroid showed linear correlated with gestational age. We assumed that the width of the thyroid could be useful for diagnosing fetal thyroid disorder when maternal thyroid disease exists.

  20. Fetal magnetic resonance imaging and human genetics

    International Nuclear Information System (INIS)

    Hengstschlaeger, Markus

    2006-01-01

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data

  1. Fetal magnetic resonance imaging and human genetics

    Energy Technology Data Exchange (ETDEWEB)

    Hengstschlaeger, Markus [Medical Genetics, Obstetrics and Gynecology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)]. E-mail: markus.hengstschlaeger@meduniwien.ac.at

    2006-02-15

    The use of fetal magnetic resonance imaging (MRI), in addition to prenatal genetic testing and sonography, has the potential to improve prenatal diagnosis of genetic disorders. MRI plays an important role in the evaluation of fetal abnormalities and malformations. Fetal MRI often enables a differential diagnosis, a determination of the extent of the disorder, the prognosis, and an improvement in therapeutic management. For counseling of parents, as well as to basically understand how genetic aberrations affect fetal development, it is of great importance to correlate different genotypes with fetal MRI data.

  2. MR imaging of the fetal brain

    International Nuclear Information System (INIS)

    Glenn, Orit A.

    2010-01-01

    Fetal MRI is clinically performed to evaluate the brain in cases where an abnormality is detected by prenatal sonography. These most commonly include ventriculomegaly, abnormalities of the corpus callosum, and abnormalities of the posterior fossa. Fetal MRI is also increasingly performed to evaluate fetuses who have normal brain findings on prenatal sonogram but who are at increased risk for neurodevelopmental abnormalities, such as complicated monochorionic twin pregnancies. This paper will briefly discuss the common clinical conditions imaged by fetal MRI as well as recent advances in fetal MRI research. (orig.)

  3. MR imaging of the fetal brain

    Energy Technology Data Exchange (ETDEWEB)

    Glenn, Orit A. [University of California, San Francisco, Department of Radiology, Neuroradiology Section, San Francisco, CA (United States)

    2010-01-15

    Fetal MRI is clinically performed to evaluate the brain in cases where an abnormality is detected by prenatal sonography. These most commonly include ventriculomegaly, abnormalities of the corpus callosum, and abnormalities of the posterior fossa. Fetal MRI is also increasingly performed to evaluate fetuses who have normal brain findings on prenatal sonogram but who are at increased risk for neurodevelopmental abnormalities, such as complicated monochorionic twin pregnancies. This paper will briefly discuss the common clinical conditions imaged by fetal MRI as well as recent advances in fetal MRI research. (orig.)

  4. Fetal body movement monitoring.

    Science.gov (United States)

    Rayburn, W F

    1990-03-01

    Recording fetal activity serves as an indirect measure of central nervous system integrity and function. The coordination of whole body movement, which requires complex neurologic control, is likely similar to that of the newborn infant. Short-term observations of the fetus are best performed using real-time ultrasound imaging. Monitoring fetal motion has been shown to be clinically worthwhile in predicting impending death or compromise, especially when placental insufficiency is longstanding. The presence of a vigorous fetus is reassuring. Perceived inactivity requires a reassessment of any underlying antepartum complication and a more precise evaluation by fetal heart rate testing or real-time ultrasonography before delivery is contemplated.

  5. Controversias actuales para definir las alteraciones del bienestar fetal Current controversies to define changes in the fetal wellbeing

    Directory of Open Access Journals (Sweden)

    Danilo Nápoles Méndez

    2013-02-01

    Full Text Available Como propuesta de diferentes sociedades científicas se estableció el término estado fetal no tranquilizador en sustitución de sufrimiento fetal, que era considerado inespecífico. Esta revisión bibliográfica se efectuó a fin de exponer a la comunidad médica los diferentes términos con que se definen las alteraciones del bienestar fetal y la influencia que el empleo de las expresiones estado fetal no tranquilizador y riesgo de pérdida del bienestar fetal generan en la práctica de Obstetricia. Asimismo, se puso énfasis en la necesidad de buscar un lenguaje técnico más unificado y se concluyó que la formación de estos términos no determina la correspondencia existente entre la evaluación prenatal del feto y su estado al nacer.As a proposal of different scientific societies the term non reassuring fetal status was coined, substituting it by fetal distress which was considered nonspecific. This literature review was carried out in order to show to the medical community the different terms with which the changes of the fetal wellbeing are defined and the influence that the use of the expressions non reassuring fetal status and the risk of loss of the fetal well-being generate in Obstetrics. Likewise, the necessity of looking for a more unified technical language was emphasized and it was concluded that these terms do not determine the existent correspondence between the prenatal evaluation of the fetus and its status at birth.

  6. Doppler changes as the earliest parameter in fetal surveillance to detect fetal compromise in intrauterine growth-restricted fetuses

    Directory of Open Access Journals (Sweden)

    Bansal Saloni

    2016-01-01

    Full Text Available Introduction. It is estimated that 3-10% of infants are growth restricted. Growth disturbances may have long-term issues. Doppler allows insight into the fetal response to intrauterine stress. Objective. The aim of this study was to detect fetal compromise in intrauterine growth-restricted (IUGR fetuses by means of biophysical profile (BPP vis-а-vis Doppler velocimetry studies of the fetal umbilical artery, and to find out which of the two is a better and earlier predictor of fetal compromise. Methods. A prospective study was conducted on a total of 50 singleton pregnancies with IUGR between 28 and 42 weeks of gestation. Study patients were managed expectantly with nonstress testing and amniotic fluid assessment, BPP and Doppler velocimetry studies of the fetal umbilical artery. Results. Fetal outcome was poor in 5/50 (10% of the fetuses, defined as presence of all of the following: poor Apgar test score, neonatal intensive care unit stay, necrotizing enterocolitis, and low birth weight. Of the four with abnormal BPP, 50% had poor fetal outcomes. Out of 46 with normal BPP, 6.5% had poor fetal outcomes. Conclusion. Inference drawn from the study is that the Doppler technology provides us the opportunity for repetitive noninvasive hemodynamic monitoring in IUGR pregnancies.

  7. Automated fetal brain segmentation from 2D MRI slices for motion correction.

    Science.gov (United States)

    Keraudren, K; Kuklisova-Murgasova, M; Kyriakopoulou, V; Malamateniou, C; Rutherford, M A; Kainz, B; Hajnal, J V; Rueckert, D

    2014-11-01

    Motion correction is a key element for imaging the fetal brain in-utero using Magnetic Resonance Imaging (MRI). Maternal breathing can introduce motion, but a larger effect is frequently due to fetal movement within the womb. Consequently, imaging is frequently performed slice-by-slice using single shot techniques, which are then combined into volumetric images using slice-to-volume reconstruction methods (SVR). For successful SVR, a key preprocessing step is to isolate fetal brain tissues from maternal anatomy before correcting for the motion of the fetal head. This has hitherto been a manual or semi-automatic procedure. We propose an automatic method to localize and segment the brain of the fetus when the image data is acquired as stacks of 2D slices with anatomy misaligned due to fetal motion. We combine this segmentation process with a robust motion correction method, enabling the segmentation to be refined as the reconstruction proceeds. The fetal brain localization process uses Maximally Stable Extremal Regions (MSER), which are classified using a Bag-of-Words model with Scale-Invariant Feature Transform (SIFT) features. The segmentation process is a patch-based propagation of the MSER regions selected during detection, combined with a Conditional Random Field (CRF). The gestational age (GA) is used to incorporate prior knowledge about the size and volume of the fetal brain into the detection and segmentation process. The method was tested in a ten-fold cross-validation experiment on 66 datasets of healthy fetuses whose GA ranged from 22 to 39 weeks. In 85% of the tested cases, our proposed method produced a motion corrected volume of a relevant quality for clinical diagnosis, thus removing the need for manually delineating the contours of the brain before motion correction. Our method automatically generated as a side-product a segmentation of the reconstructed fetal brain with a mean Dice score of 93%, which can be used for further processing. Copyright

  8. Fetal stimulation by pulsed diagnostic ultrasound.

    Science.gov (United States)

    Fatemi, M; Ogburn, P L; Greenleaf, J F

    2001-08-01

    To show that pulsed ultrasound from a clinical ultrasonic imaging system can stimulate the fetus. Stimulation is defined mainly as increased fetal gross body movements in response to excitation. Fetuses of a group of 9 volunteer women (mean gestational age, 33.37 weeks; range, 25-40 weeks) were evaluated for body movement under 3 different conditions: (1) control, with no ultrasound exposure; (2) ultrasound in continuous wave Doppler mode; and (3) pulsed ultrasound in pulsed Doppler and B modes. A conventional external fetal monitor, with negligible ultrasonic output, was used to monitor fetal gross body motions. After an initial rest period of 3 minutes with 1 or no fetal motion, fetuses were monitored for an additional 3 minutes under the exposure criterion defined for each condition. Resulting fetal motions under the 3 conditions were compared using the Wilcoxon signed rank test. The test showed that fetuses moved significantly more frequently under condition 3 (mean +/- SD, 3.43 +/- 1.93 movements per minute) than under condition 1 (0.40 +/- 7.33 movements per minute) or condition 2 (0.63 +/- 7.67 movements per minute); P = .004 and .016, respectively. Fetal movements under conditions 1 and 2 did not differ significantly. Diagnostic ultrasound may stimulate fetal body motion.

  9. MRI of fetal acquired brain lesions

    International Nuclear Information System (INIS)

    Prayer, Daniela; Brugger, Peter C.; Kasprian, Gregor; Witzani, Linde; Helmer, Hanns; Dietrich, Wolfgang; Eppel, Wolfgang; Langer, Martin

    2006-01-01

    Acquired fetal brain damage is suspected in cases of destruction of previously normally formed tissue, the primary cause of which is hypoxia. Fetal brain damage may occur as a consequence of acute or chronic maternal diseases, with acute diseases causing impairment of oxygen delivery to the fetal brain, and chronic diseases interfering with normal, placental development. Infections, metabolic diseases, feto-fetal transfusion syndrome, toxic agents, mechanical traumatic events, iatrogenic accidents, and space-occupying lesions may also qualify as pathologic conditions that initiate intrauterine brain damage. MR manifestations of acute fetal brain injury (such as hemorrhage or acute ischemic lesions) can easily be recognized, as they are hardly different from postnatal lesions. The availability of diffusion-weighted sequences enhances the sensitivity in recognizing acute ischemic lesions. Recent hemorrhages are usually readily depicted on T2 (*) sequences, where they display hypointense signals. Chronic fetal brain injury may be characterized by nonspecific changes that must be attributable to the presence of an acquired cerebral pathology. The workup in suspected acquired fetal brain injury also includes the assessment of extra-CNS organs that may be affected by an underlying pathology. Finally, the placenta, as the organ that mediates oxygen delivery from the maternal circulation to the fetus, must be examined on MR images

  10. MRI of fetal acquired brain lesions

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Radiodiagnostics, Medical University of Vienna (Austria)]. E-mail: daniela.prayer@meduniwien.ac.at; Brugger, Peter C. [Center of Anatomy and Cell Biology, Medical University of Vienna (Austria); Kasprian, Gregor [Department of Radiodiagnostics, Medical University of Vienna (Austria); Witzani, Linde [Department of Radiodiagnostics, Medical University of Vienna (Austria); Helmer, Hanns [Department of Obstetrics and Gynecology, Medical University of Vienna (Austria); Dietrich, Wolfgang [Department of Neurosurgery, Medical University of Vienna (Austria); Eppel, Wolfgang [Department of Obstetrics and Gynecology, Medical University of Vienna (Austria); Langer, Martin [Department of Obstetrics and Gynecology, Medical University of Vienna (Austria)

    2006-02-15

    Acquired fetal brain damage is suspected in cases of destruction of previously normally formed tissue, the primary cause of which is hypoxia. Fetal brain damage may occur as a consequence of acute or chronic maternal diseases, with acute diseases causing impairment of oxygen delivery to the fetal brain, and chronic diseases interfering with normal, placental development. Infections, metabolic diseases, feto-fetal transfusion syndrome, toxic agents, mechanical traumatic events, iatrogenic accidents, and space-occupying lesions may also qualify as pathologic conditions that initiate intrauterine brain damage. MR manifestations of acute fetal brain injury (such as hemorrhage or acute ischemic lesions) can easily be recognized, as they are hardly different from postnatal lesions. The availability of diffusion-weighted sequences enhances the sensitivity in recognizing acute ischemic lesions. Recent hemorrhages are usually readily depicted on T2 (*) sequences, where they display hypointense signals. Chronic fetal brain injury may be characterized by nonspecific changes that must be attributable to the presence of an acquired cerebral pathology. The workup in suspected acquired fetal brain injury also includes the assessment of extra-CNS organs that may be affected by an underlying pathology. Finally, the placenta, as the organ that mediates oxygen delivery from the maternal circulation to the fetus, must be examined on MR images.

  11. Placental adaptations to the maternal-fetal environment: implications for fetal growth and developmental programming.

    Science.gov (United States)

    Sandovici, Ionel; Hoelle, Katharina; Angiolini, Emily; Constância, Miguel

    2012-07-01

    The placenta is a transient organ found in eutherian mammals that evolved primarily to provide nutrients for the developing fetus. The placenta exchanges a wide array of nutrients, endocrine signals, cytokines and growth factors with the mother and the fetus, thereby regulating intrauterine development. Recent studies show that the placenta is not just a passive organ mediating maternal-fetal exchange. It can adapt its capacity to supply nutrients in response to intrinsic and extrinsic variations in the maternal-fetal environment. These dynamic adaptations are thought to occur to maximize fetal growth and viability at birth in the prevailing conditions in utero. However, some of these adaptations may also affect the development of individual fetal tissues, with patho-physiological consequences long after birth. Here, this review summarizes current knowledge on the causes, possible mechanisms and consequences of placental adaptive responses, with a focus on the regulation of transporter-mediated processes for nutrients. This review also highlights the emerging roles that imprinted genes and epigenetic mechanisms of gene regulation may play in placental adaptations to the maternal-fetal environment. Copyright © 2012 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Fetal Primary Cardiac Tumors During Perinatal Period

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2017-06-01

    Full Text Available Fetal primary cardiac tumors are rare, but they may cause complications, which are sometimes life threatening, including arrhythmias, hydrops fetalis, ventricular outflow/inflow obstruction, cardiac failure, and even sudden death. Among fetal primary cardiac tumors, rhabdomyomas are most common, followed by teratomas, fibromas, hemangiomas, and myxomas. Everolimus, a mammalian target of rapamycin inhibitor, has been reported to be an effective drug to cause tumor remission in three neonates with multiple cardiac rhabdomyomas. Neonatal cardiac surgery for the resection of primary cardiac tumors found by fetal echocardiography has been reported sporadically. However, open fetal surgery for pericardial teratoma resection, which was performed successfully via a fetal median sternotomy in one case report, could be a promising intervention to rescue these patients with large pericardial effusions. These recent achievements undoubtedly encourage further development in early management of fetal cardiac tumors. Owing to the rarity of fetal primary cardiac tumors, relevant information in terms of prenatal diagnosis, treatment, and prognosis remains to be clarified.

  13. Perspectives of fetal dystocia in cattle and buffalo

    Directory of Open Access Journals (Sweden)

    Govind Narayan Purohit

    2012-04-01

    Full Text Available We review the causes of fetal dystocia in cows and buffalo. Two fetal causes are distinct fetal oversize and fetal abnormalities. Fetal oversize is common in heifers, cows of beef cattle breeds, prolonged gestations, increased calf birth weight, male calves and perinatal fetal death with resultant emphysema. Fetal abnormalities include monsters, fetal diseases and fetal maldispositions, and it is difficult to deliver such fetuses because of their altered shape. Although monsters are rare in cattle, a large number of monstrosities have been reported in river buffalo; yet also here, overall incidence is low. Diseases of the fetus resulting in dystocia include hydrocephalus, ascites, anasarca and hydrothorax. The most common cause of dystocia in cattle seems to be fetal maldispositions, of which limb flexion and head deviation appear to be the most frequent. We provide a brief description of the management of dystocia from different causes in cattle and buffalo. A case analysis of 192 and 112 dystocia in cattle and buffalo, respectively, at our referral center revealed that dystocia is significantly higher (P<0.05 in first and second parity cows and buffalo, and that dystocia of fetal origin is common in cows (65.62% but less frequent (40.17% in buffalo. In buffalo, the single biggest cause of dystocia was uterine torsion (53.57%. Fetal survival was significantly (P<0.05 higher both in cows and buffalo when delivery was completed within 12 h of second stage of labor.

  14. Prognostic Significance of Preterm Isolated Decreased Fetal Movement

    Directory of Open Access Journals (Sweden)

    Ertuğrul Karahanoğlu

    2017-12-01

    Full Text Available Objective: Our aim is to evaluate the prognostic significance of isolated, preterm decreased fetal movement following normal initial full diagnostic workup. Study design: A retrospective observational study was conducted at a tertiary centre. The applied protocol was approved by the Medical Research Ethics Department of the hospital where the research was conducted. Obstetrics outcomes of preterm- and term-decreased fetal movement were compared following an initial, normal diagnostic work up. Evaluated outcomes were birth weight, mode of delivery, stillbirth rate, induction of labour, development of gestational hypertension, small for gestational age and oligohydramnios, polyhydramnios during the follow up period. Result: Obstetric complications related to placental insufficiency develops more frequently for decreased fetal movement in preterm cases with respect to that of in term cases. Following the diagnosis of decreased fetal movement, pregnancy hypertension occurred in 17% of preterm decreased fetal movement cases and in 4.7% of term decreased fetal movement cases. Fetal growth restriction developed in 6.6% of preterm decreased fetal movement and in 2.3% of term decreased fetal movement. Amniotic fluid abnormalities more frequently developed in preterm decreased fetal movement. Conclusion: Following an initial normal diagnostic workup, preterm decreased fetal movement convey a higher risk for the development of pregnancy complications associated with placental insufficiency. The patient should be monitored closely and management protocols must be developed for initial normal diagnostic workups in cases of preterm decreased fetal movement.

  15. Medio ambiente fetal Fetal environment

    Directory of Open Access Journals (Sweden)

    César Bernardo Ospina Arcila

    1996-04-01

    Full Text Available Con base en el artículo clásico "Monte Everest in utero" se hace un análisis de la situación que afronta el feto con respecto a la disponibilidad de oxígeno; para una mejor comprensión del sufrimiento fetal se revisan los siguientes conceptos: presión barométrica, presión parcial del oxígeno atmosférico, presión parcial del oxígeno inspirado, presión barométrica intranasal, ecuación del gas alveolar y difusión de gases a través de la membrana alvéolo capilar. Based on the classical paper by Eastman "Mount Everest in utero" an analysis is made of the situation faced by the fetus with respect to the availability of oxygen; for a better under. standing of fetal distress the following concepts are reviewed: barometric pressure, partial pressure of atmosferic oxygen, partial pressure of inspired oxygen, barometric intranasal pressure, alveolar gas equation and gas diffusion through alveolo-capilar membrane.

  16. Imprinted NanoVelcro Microchips for Isolation and Characterization of Circulating Fetal Trophoblasts: Toward Noninvasive Prenatal Diagnostics

    OpenAIRE

    Hou, Shuang; Chen, Jie-Fu; Song, Min; Zhu, Yazhen; Jan, Yu Jen; Chen, Szu Hao; Weng, Tzu-Hua; Ling, Dean-An; Chen, Shang-Fu; Ro, Tracy; Liang, An-Jou; Lee, Tom; Jin, Helen; Li, Man; Liu, Lian

    2017-01-01

    Circulating fetal nucleated cells (CFNCs) in maternal blood offer an ideal source of fetal genomic DNA for noninvasive prenatal diagnostics (NIPD). We developed a class of nanoVelcro microchips to effectively enrich a subcategory of CFNCs, i.e., circulating trophoblasts (cTBs) from maternal blood, which can then be isolated with single-cell resolution by a laser capture microdissection (LCM) technique for downstream genetic testing. We first established a nanoimprinting fabrication process to...

  17. The Use of Fetal Noninvasive Electrocardiography

    Directory of Open Access Journals (Sweden)

    Igor Lakhno

    2016-01-01

    Full Text Available Preeclampsia (PE is one of the severe complications of pregnancy that leads to fetal deterioration. The aim was to survey the validity of fetal distress diagnostics in case of Doppler ultrasonic umbilical vein and arteries blood flow velocity investigation and ECG parameters analysis obtained from maternal abdominal signal before labor in preeclamptic patients. Fetal noninvasive ECG and umbilical arterial and venous Doppler investigation were performed in 120 patients at 34–40 weeks of gestation. And 30 of them had physiological gestation and were involved in Group I. In Group II 52 pregnant women with mild-moderate PE were observed. 38 patients with severe PE were monitored in Group III. The most considerable negative correlation was determined in pair Apgar score 1 versus T/QRS (R=-0.50; p<0.05. So the increased T/QRS ratio was the most evident marker of fetal distress. Fetal noninvasive ECG showed sensitivity of 96.6% and specificity of 98.4% and, therefore, was determined as more accurate method for fetal monitoring.

  18. Maternal feeding controls fetal biological clock.

    Directory of Open Access Journals (Sweden)

    Hidenobu Ohta

    Full Text Available BACKGROUND: It is widely accepted that circadian physiological rhythms of the fetus are affected by oscillators in the maternal brain that are coupled to the environmental light-dark (LD cycle. METHODOLOGY/PRINCIPAL FINDINGS: To study the link between fetal and maternal biological clocks, we investigated the effects of cycles of maternal food availability on the rhythms of Per1 gene expression in the fetal suprachiasmatic nucleus (SCN and liver using a transgenic rat model whose tissues express luciferase in vitro. Although the maternal SCN remained phase-locked to the LD cycle, maternal restricted feeding phase-advanced the fetal SCN and liver by 5 and 7 hours respectively within the 22-day pregnancy. CONCLUSIONS/SIGNIFICANCE: Our results demonstrate that maternal feeding entrains the fetal SCN and liver independently of both the maternal SCN and the LD cycle. This indicates that maternal-feeding signals can be more influential for the fetal SCN and particular organ oscillators than hormonal signals controlled by the maternal SCN, suggesting the importance of a regular maternal feeding schedule for appropriate fetal molecular clockwork during pregnancy.

  19. The Danish Fetal Medicine Database

    Directory of Open Access Journals (Sweden)

    Ekelund CK

    2016-10-01

    Full Text Available Charlotte Kvist Ekelund,1 Tine Iskov Kopp,2 Ann Tabor,1 Olav Bjørn Petersen3 1Department of Obstetrics, Center of Fetal Medicine, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark; 2Registry Support Centre (East – Epidemiology and Biostatistics, Research Centre for Prevention and Health, Glostrup, Denmark; 3Fetal Medicine Unit, Aarhus University Hospital, Aarhus Nord, Denmark Aim: The aim of this study is to set up a database in order to monitor the detection rates and false-positive rates of first-trimester screening for chromosomal abnormalities and prenatal detection rates of fetal malformations in Denmark. Study population: Pregnant women with a first or second trimester ultrasound scan performed at all public hospitals in Denmark are registered in the database. Main variables/descriptive data: Data on maternal characteristics, ultrasonic, and biochemical variables are continuously sent from the fetal medicine units' Astraia databases to the central database via web service. Information about outcome of pregnancy (miscarriage, termination, live birth, or stillbirth is received from the National Patient Register and National Birth Register and linked via the Danish unique personal registration number. Furthermore, results of all pre- and postnatal chromosome analyses are sent to the database. Conclusion: It has been possible to establish a fetal medicine database, which monitors first-trimester screening for chromosomal abnormalities and second-trimester screening for major fetal malformations with the input from already collected data. The database is valuable to assess the performance at a regional level and to compare Danish performance with international results at a national level. Keywords: prenatal screening, nuchal translucency, fetal malformations, chromosomal abnormalities

  20. Fetal responses to induced maternal relaxation during pregnancy

    OpenAIRE

    DiPietro, Janet A.; Costigan, Kathleen A.; Nelson, Priscilla; Gurewitsch, Edith D.; Laudenslager, Mark L.

    2007-01-01

    Fetal responses to induced maternal relaxation during the 32nd week of pregnancy were recorded in 100 maternal-fetal pairs using a digitized data collection system. The 18-minute guided imagery relaxation manipulation generated significant changes in maternal heart rate, skin conductance, respiration period, and respiratory sinus arrhythmia. Significant alterations in fetal neurobehavior were observed, including decreased fetal heart rate (FHR), increased FHR variability, suppression of fetal...

  1. Ultrasonographic determination of fetal gender

    International Nuclear Information System (INIS)

    Kim, Il Young; Kim, Dae Ho; Lee, Byung Ho; Bae, Dong Han

    1985-01-01

    Sonographic determination of fetal gender was attempted prospectively in most pregnancies of more than 26 weeks. We studied 193 cases of pregnancies with ultrasound for recent 9 months from June 1984 to February 1985 at department of radiology, Soonchunhyang university, Soonchunhyang Chunan hospital, and analysed ultrasonographic finding of fetal gender. The results were as follows; 1. Overall accuracy rate for fetal gender is 90%. 2. Accuracy rate for male fetus is 97.8%. 3. Accuracy rate for female fetus is 88.2%

  2. Ultrasonic prediction of fetal mass

    African Journals Online (AJOL)

    1983-02-19

    Feb 19, 1983 ... Summary. A clinically accurate method for estimating fetal. mass from fetal body parameters is reviewed. The abdominal circumference is first calculated from ... reliable clinical parameter is the impression of uterine volume,.

  3. Fetal microchimeric cells in autoimmune thyroid diseases

    Science.gov (United States)

    Lepez, Trees; Vandewoestyne, Mado; Deforce, Dieter

    2013-01-01

    Autoimmune thyroid diseases (AITD) show a female predominance, with an increased incidence in the years following parturition. Fetal microchimerism has been suggested to play a role in the pathogenesis of AITD. However, only the presence of fetal microchimeric cells in blood and in the thyroid gland of these patients has been proven, but not an actual active role in AITD. Is fetal microchimerism harmful for the thyroid gland by initiating a Graft versus Host reaction (GvHR) or being the target of a Host versus Graft reaction (HvGR)? Is fetal microchimerism beneficial for the thyroid gland by being a part of tissue repair or are fetal cells just innocent bystanders in the process of autoimmunity? This review explores every hypothesis concerning the role of fetal microchimerism in AITD. PMID:23723083

  4. Measurement of the capability of DNA synthesis of human fetal liver cells by the assay of 3H-TdR incorporation

    International Nuclear Information System (INIS)

    Wang Tao; Ma Xiangrui; Wang Hongyun; Cao Xia

    1987-01-01

    The fetal liver is one of the major sites of hematopoiesis during gestation. Under erythropoietin (EPO) stimulation, in erythroid precusor cells of fetal liver, proliferation and differentiation occurred and function of metabolism was enhanced. The technique of 3 H-TdR incorporation was used to measure the function of fetal liver cellular DNA synthesis. As EPO concentration at the range of approximately 20 ∼ 100 mU/ml, the counts of 3 H-TdR incorporation into fetal liver cells increased. As the concentration of EPO increased, however, its incorporation counts are lower than that in bone marrow of either the fetal or the adult. It suggested that precusors of erythrocyte of fetal liver has differentiated to later phases with the progressive accumulation of mature cells, therefore, both proliferation and function of metabolism are more or less decreased respectively. Under EPO stimulation, however, precusor of erythroid of fetal liver can greatly increase potential effects on DNA synthesis

  5. Fetal responses to induced maternal relaxation during pregnancy.

    Science.gov (United States)

    DiPietro, Janet A; Costigan, Kathleen A; Nelson, Priscilla; Gurewitsch, Edith D; Laudenslager, Mark L

    2008-01-01

    Fetal responses to induced maternal relaxation during the 32nd week of pregnancy were recorded in 100 maternal-fetal pairs using a digitized data collection system. The 18-min guided imagery relaxation manipulation generated significant changes in maternal heart rate, skin conductance, respiration period, and respiratory sinus arrhythmia. Significant alterations in fetal neurobehavior were observed, including decreased fetal heart rate (FHR), increased FHR variability, suppression of fetal motor activity (FM), and increased FM-FHR coupling. Attribution of the two fetal cardiac responses to the guided imagery procedure itself, as opposed to simple rest or recumbency, is tempered by the observed pattern of response. Evaluation of correspondence between changes within individual maternal-fetal pairs revealed significant associations between maternal autonomic measures and fetal cardiac patterns, lower umbilical and uterine artery resistance and increased FHR variability, and declining salivary cortisol and FM activity. Potential mechanisms that may mediate the observed results are discussed.

  6. The Danish fetal medicine database

    DEFF Research Database (Denmark)

    Ekelund, Charlotte Kvist; Kopp, Tine Iskov; Tabor, Ann

    2016-01-01

    trimester ultrasound scan performed at all public hospitals in Denmark are registered in the database. Main variables/descriptive data: Data on maternal characteristics, ultrasonic, and biochemical variables are continuously sent from the fetal medicine units’Astraia databases to the central database via...... analyses are sent to the database. Conclusion: It has been possible to establish a fetal medicine database, which monitors first-trimester screening for chromosomal abnormalities and second-trimester screening for major fetal malformations with the input from already collected data. The database...

  7. T2* relaxometry of fetal brain at 1.5 Tesla using a motion tolerant method.

    Science.gov (United States)

    Vasylechko, Serge; Malamateniou, Christina; Nunes, Rita G; Fox, Matthew; Allsop, Joanna; Rutherford, Mary; Rueckert, Daniel; Hajnal, Joseph V

    2015-05-01

    The aim of this study was to determine T2* values for the fetal brain in utero and to compare them with previously reported values in preterm and term neonates. Knowledge of T2* may be useful for assessing brain development, brain abnormalities, and for optimizing functional imaging studies. Maternal respiration and unpredictable fetal motion mean that conventional multishot acquisition techniques used in adult T2* relaxometry studies are not practical. Single shot multiecho echo planar imaging was used as a rapid method for measuring fetal T2* by effectively freezing intra-slice motion. T2* determined from a sample of 24 subjects correlated negatively with gestational age with mean values of 220 ms (±45) for frontal white matter, 159 ms (±32) for thalamic gray matter, and 236 ms (±45) for occipital white matter. Fetal T2* values are higher than those previously reported for preterm neonates and decline with a consistent trend across gestational age. The data suggest that longer than usual echo times or direct T2* measurement should be considered when performing fetal fMRI to reach optimal BOLD sensitivity. © 2014 Wiley Periodicals, Inc.

  8. Monitoring fetal heart rate during pregnancy: contributions from advanced signal processing and wearable technology.

    Science.gov (United States)

    Signorini, Maria G; Fanelli, Andrea; Magenes, Giovanni

    2014-01-01

    Monitoring procedures are the basis to evaluate the clinical state of patients and to assess changes in their conditions, thus providing necessary interventions in time. Both these two objectives can be achieved by integrating technological development with methodological tools, thus allowing accurate classification and extraction of useful diagnostic information. The paper is focused on monitoring procedures applied to fetal heart rate variability (FHRV) signals, collected during pregnancy, in order to assess fetal well-being. The use of linear time and frequency techniques as well as the computation of non linear indices can contribute to enhancing the diagnostic power and reliability of fetal monitoring. The paper shows how advanced signal processing approaches can contribute to developing new diagnostic and classification indices. Their usefulness is evaluated by comparing two selected populations: normal fetuses and intra uterine growth restricted (IUGR) fetuses. Results show that the computation of different indices on FHRV signals, either linear and nonlinear, gives helpful indications to describe pathophysiological mechanisms involved in the cardiovascular and neural system controlling the fetal heart. As a further contribution, the paper briefly describes how the introduction of wearable systems for fetal ECG recording could provide new technological solutions improving the quality and usability of prenatal monitoring.

  9. Fetal programming of renal function.

    Science.gov (United States)

    Dötsch, Jörg; Plank, Christian; Amann, Kerstin

    2012-04-01

    Results from large epidemiological studies suggest a clear relation between low birth weight and adverse renal outcome evident as early as during childhood. Such adverse outcomes may include glomerular disease, hypertension, and renal failure and contribute to a phenomenon called fetal programming. Other factors potentially leading to an adverse renal outcome following fetal programming are maternal diabetes mellitus, smoking, salt overload, and use of glucocorticoids during pregnancy. However, clinical data on the latter are scarce. Here, we discuss potential underlying mechanisms of fetal programming, including reduced nephron number via diminished nephrogenesis and other renal (e.g., via the intrarenal renin-angiotensin-aldosterone system) and non-renal (e.g., changes in endothelial function) alterations. It appears likely that the outcomes of fetal programming may be influenced or modified postnatally, for example, by the amount of nutrients given at critical times.

  10. Novel applications of quantitative MRI for the fetal brain

    Energy Technology Data Exchange (ETDEWEB)

    Clouchoux, Cedric [Children' s National Medical Center, Division of Diagnostic Imaging and Radiology, Washington, DC (United States); Limperopoulos, Catherine [Children' s National Medical Center, Division of Diagnostic Imaging and Radiology, Washington, DC (United States); McGill University, McConnell Brain Imaging Center, Montreal Neurological Institute, Montreal (Canada); McGill University, Department of Neurology and Neurosurgery, Montreal (Canada); Children' s National Medical Center, Division of Fetal and Transitional Medicine, Washington, DC (United States)

    2012-01-15

    The advent of ultrafast MRI acquisitions is offering vital insights into the critical maturational events that occur throughout pregnancy. Concurrent with the ongoing enhancement of ultrafast imaging has been the development of innovative image-processing techniques that are enabling us to capture and quantify the exuberant growth, and organizational and remodeling processes that occur during fetal brain development. This paper provides an overview of the role of advanced neuroimaging techniques to study in vivo brain maturation and explores the application of a range of new quantitative imaging biomarkers that can be used clinically to monitor high-risk pregnancies. (orig.)

  11. Prevention of fetal demise and growth restriction in a mouse model of fetal alcohol syndrome.

    Science.gov (United States)

    Spong, C Y; Abebe, D T; Gozes, I; Brenneman, D E; Hill, J M

    2001-05-01

    Two peptides [NAPVSIPQ (NAP) and SALLRSIPA (ADNF-9)], that are associated with novel glial proteins regulated by vasoactive intestinal peptide, are shown now to provide protective intervention in a model of fetal alcohol syndrome. Fetal demise and growth restrictions were produced after intraperitoneal injection of ethanol to pregnant mice during midgestation (E8). Death and growth abnormalities elicited by alcohol treatment during development are believed to be associated, in part, with severe oxidative damage. NAP and ADNF-9 have been shown to exhibit antioxidative and antiapoptotic actions in vitro. Pretreatment with an equimolar combination of the peptides prevented the alcohol-induced fetal death and growth abnormalities. Pretreatment with NAP alone resulted in a significant decrease in alcohol-associated fetal death; whereas ADNF-9 alone had no detectable effect on fetal survival after alcohol exposure, indicating a pharmacological distinction between the peptides. Biochemical assessment of the fetuses indicated that the combination peptide treatment prevented the alcohol-induced decreases in reduced glutathione. Peptide efficacy was evident with either 30-min pretreatment or with 1-h post-alcohol administration. Bioavailability studies with [(3)H]NAPVSIPQ indicated that 39% of the total radioactivity comigrated with intact peptide in the fetus 60 min after administration. These studies demonstrate that fetal death and growth restriction associated with prenatal alcohol exposure were prevented by combinatorial peptide treatment and suggest that this therapeutic strategy be explored in other models/diseases associated with oxidative stress.

  12. Right atrial hemangioma in the newborn: Utility of fetal imaging

    International Nuclear Information System (INIS)

    Baird, Christopher; Blalock, Shannon; Bengur, Resai; Ikemba, Catherine

    2012-01-01

    We present a rare primary right atrial tumor diagnosed in-utero with fetal echocardiography, and further characterized as a congenital hemangioma with magnetic resonance imaging. Surgical resection was done six days after birth. This case illustrates the complementary roles of evolving advanced imaging techniques for fetuses and infants with congenital heart disease that allows for surgery early in the neonatal period

  13. [The woman at the termination of pregnancy for fetal anomalies: clinical case].

    Science.gov (United States)

    Baena-Antequera, Francisca; Jurado-García, Estefanía

    2015-01-01

    Within the assistance and support to coping with perinatal death, it must be considered that there is a group of women whose process has some features that give specific connotations. We talked about when the perinatal loss occurs due to a maternal decision to the presence of a fetal malformation. These cases today, thanks to advances in the techniques of control fetal development, are not uncommon. In their assistance, healthcare professionals should be aware that they often present a great sense of guilt and ambivalence between well-made decision and the hardness of having to come to it. A case of a pregnant woman undergoing a fetal fetolisis and care plan developed in her assistance for the induction of labor, delivery and immediate postpartum period is presented. This plan includes the problems of collaboration and the independent problems that are formulated according to the NANDA, NOC and NIC taxonomies. The implication for practice after studying this case leads to the duty to equally address the coping with a stillbirth, whether it was spontaneous or had it been determined by fetal malformation completion, giving parents the ability to view and contact with their child. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  14. Fetal MRI: An approach to practice: A review

    Directory of Open Access Journals (Sweden)

    Sahar N. Saleem

    2014-09-01

    Full Text Available MRI has been increasingly used for detailed visualization of the fetus in utero as well as pregnancy structures. Yet, the familiarity of radiologists and clinicians with fetal MRI is still limited. This article provides a practical approach to fetal MR imaging. Fetal MRI is an interactive scanning of the moving fetus owed to the use of fast sequences. Single-shot fast spin-echo (SSFSE T2-weighted imaging is a standard sequence. T1-weighted sequences are primarily used to demonstrate fat, calcification and hemorrhage. Balanced steady-state free-precession (SSFP, are beneficial in demonstrating fetal structures as the heart and vessels. Diffusion weighted imaging (DWI, MR spectroscopy (MRS, and diffusion tensor imaging (DTI have potential applications in fetal imaging. Knowing the developing fetal MR anatomy is essential to detect abnormalities. MR evaluation of the developing fetal brain should include recognition of the multilayered-appearance of the cerebral parenchyma, knowledge of the timing of sulci appearance, myelination and changes in ventricular size. With advanced gestation, fetal organs as lungs and kidneys show significant changes in volume and T2-signal. Through a systematic approach, the normal anatomy of the developing fetus is shown to contrast with a wide spectrum of fetal disorders. The abnormalities displayed are graded in severity from simple common lesions to more complex rare cases. Complete fetal MRI is fulfilled by careful evaluation of the placenta, umbilical cord and amniotic cavity. Accurate interpretation of fetal MRI can provide valuable information that helps prenatal counseling, facilitate management decisions, guide therapy, and support research studies.

  15. Linear and nonlinear features of fetal heart rate on the assessment of fetal development in the course of pregnancy and the impact of fetal gender.

    Science.gov (United States)

    Spyridou, K; Chouvarda, I; Hadjileontiadis, L; Maglaveras, N

    2018-01-30

    This work aims to investigate the impact of gestational age and fetal gender on fetal heart rate (FHR) tracings. Different linear and nonlinear parameters indicating correlation or complexity were used to study the influence of fetal age and gender on FHR tracings. The signals were recorded from 99 normal pregnant women in a singleton pregnancy at gestational ages from 28 to 40 weeks, before the onset of labor. There were 56 female fetuses and 43 male. Analysis of FHR shows that the means as well as measures of irregularity of FHR, such as approximate entropy and algorithmic complexity, decrease as gestation progresses. There were also indications that mutual information and multiscale entropy were lower in male fetuses in early pregnancy. Fetal age and gender seem to influence FHR tracings. Taking this into consideration would improve the interpretation of FHR monitoring.

  16. Awareness of fetal echo in Indian scenario

    International Nuclear Information System (INIS)

    Warrier, Dhanya; Saraf, Rahul; Maheshwari, Sunita; Suresh, PV; Shah, Sejal

    2012-01-01

    Fetal echocardiography is a well established sensitive tool to diagnose congenital heart disease (CHD) in utero. One of the determinants of effective utilization of fetal echocardiography is its awareness in the general population. The present hospital based study was undertaken to assess the awareness of the need for fetal echocardiography amongst Indian parents. One thousand one hundred and thirty eight consecutive parents who visited the pediatric cardiology outpatient department of a tertiary care centre over a period of two months were asked to fill up a questionnaire that included their demographic data, educational status, history of CHD in children, awareness of fetal echocardiography and source of information and timing of fetal echocardiogram if performed. The data was categorized and awareness was noted in different groups. The awareness in the study population was 2.2%. Awareness was found to be similar across the study population irrespective of the demographics and high risk status of the parents. The awareness of fetal echocardiography, an important tool in reducing the incidence of complex CHD, thereby impacting public health, is alarmingly low in the population studied. Appropriate action to increase awareness of fetal echocardiography needs to be looked into

  17. First Trimester Fetal Gender Assignment by Ultrasound

    Directory of Open Access Journals (Sweden)

    Sabahattin Altunyurt

    2010-03-01

    Full Text Available Objective: To investigate the efficiency of genital tubercule angle on detecting fetal gender in first trimester by ultrasonography. Material-Method: Fetal sex assignment by ultrasound was carried out in 172 pregnancies at 11-13+6 weeks between 2007 June and 2007 December. Gestational age was determined by the measurement of crown-rump length (CRL. The ultrasound predictions were compared with actual sex at birth. Mid-sagittal planes of a section of the fetal genital tubercle were performed to identify the gender. Results: 155 of 172 patients’ data were achieved. The overall success rate was 92.3 % in sonographic assignment of fetal sex. The correct assignment rate in female fetuses was significantly higher than males (95.9 % - 88.8 % [p=0,001]. The correct identification of fetal sex improved with advancing gestational age from 89.3 % between 11-11+6 weeks, 92.5 % between 12-12+6 weeks and 93.4 % between 13-13+6 weeks (p=0,96. Conclusion: The fetal sex assignment by ultrasonography between 11-13+6 weeks had high success rate. The sensitivity of fetal sex assignment was not affected with fetus position and gestational age.

  18. Fetal activity patterns in hypertensive pregnancies.

    Science.gov (United States)

    Rayburn, W F

    1982-01-01

    This prospective investigation attempts to determine whether the maternal recording of perceived fetal motion is useful for fetal assessment in pregnancies complicated by hypertension. During a 21 month period, 124 patients whose pregnancies were complicated by either chronic or pregnancy-induced hypertension participated. The number of perceived movements per hour (24 +/- 11, mean +/- S.D.) and evidence for fetal inactivity (7 cases, 6%) did not vary significantly from a control group of normotensive pregnancies (p greater than 0.05). Fetal inactivity was predictive of an unfavorable perinatal outcome in 6 of 7 cases, including the three stillborn infants. No perinatal deaths occurred among the 117 hypertensive pregnancies with active fetuses, and the 6 cases with an unfavorable outcome were associated with mild intrauterine growth delay, prematurity, or acute changes such as placental abruption or umbilical cord accidents. Realizing these limitations, a record of fetal inactivity is worthwhile in managing the pregnancy complicated by hypertension.

  19. Inequality in Fetal Autopsy in Canada.

    Science.gov (United States)

    Auger, Nathalie; Tiandrazana, Rémi-Claude; Healy-Profitós, Jessica; Costopoulos, André

    2016-01-01

    Inequality in use of fetal autopsy is poorly understood, despite the importance of autopsy in establishing the cause of stillbirth for future prevention. We examined fetal autopsy rates between linguistic minorities in Quebec, Canada, and assessed trends over three decades. Using registry data on 11,992 stillbirths from 1981-2011, we calculated fetal autopsy rates for Francophones, Anglophones, and Allophones by decade. We found lower fetal autopsy rates for Allophones (54.4%) than Francophones (68.5%) and Anglophones (63.4%), but rates decreased over time for all language groups. After 2000, Allophones had 25% higher risk of non-autopsy relative to Francophones, with 8.8 fewer autopsies for every 100 stillbirths. Allophones who were not autopsied had 32% higher risk of having an undetermined cause of death. Inequality in use of fetal autopsy may be widespread for minorities in Canada. Efforts to decrease stillbirth in minorities may require policies to increase autopsy rates.

  20. Studies by radioiodination of normal adult, fetal and leukemic cell membranes

    Energy Technology Data Exchange (ETDEWEB)

    Kannourakis, G; Cauchi, M N [Department of Pathology and Immunology, Monash Medical School, Melbourne, Australia

    1978-01-01

    A comparison was made between cord blood lymphocytes, normal adult lymphocytes and leukemic cells after membrane iodination with lactoperoxidase. A double-labeling technique using lactoperoxidase iodination with /sup 125/I and /sup 131/I followed by analysis on polyacrylamide gel electrophoresis revealed a number of membrane differences between leukemic, normal and fetal cells. There was a reduction in the 70,000 molecular weight component in cord blood cells compared to adult lymphocytes, and an increase in membrane peptides with molecular weights of 35,000, 20,000, 9,000 and 4,000. Although smaller molecular weight peptides were also present in chronic lymphatic leukemia as well as acute myeloid leukemia, these were shown to be distinct from fetal type membrane components.

  1. Sex determination using free fetal DNA in early pregnancy: With the approach to sex linked recessive disorders

    Directory of Open Access Journals (Sweden)

    Amir Monfaredan

    2017-03-01

    Full Text Available Introduction: Prenatal diagnosis is testing for detection of diseases or conditions in a fetus or embryo before it is born. Most of prenatal diagnostic (PD techniques are invasive and done in late stages of pregnancy. Using fetal DNA in maternal blood for fetal sex determination in early pregnancy might help in management of X-linked genetic diseases. This study aimed to investigate the accuracy of sex determination using fetal DNA in maternal blood at 8-12 weeks of gestation. Methods: In this cross-sectional study, 30 pregnant women at 8-12 weeks of gestation were enrolled. The sex-determining region Y (SRY gene expression with the internal control (IC glyceraldehyde 3-phosphate dehydrogenase (GAPDH was investigated with quantitative real-time polymerase chain reaction (PCR using specific primers and probes. Results: Accuracy of sex determination with SRY gene expression in 8-12 weeks of pregnancy were 85%, 85%, 90% and 100% respectively. Conclusion: It seems that fetal sex determining using fetal DNA in maternal blood is a reliable method for early stage of pregnancy.

  2. Fetal alcohol exposure and development of the integument

    Directory of Open Access Journals (Sweden)

    Longhurst WD

    2016-05-01

    Full Text Available William D Longhurst,1 Jordan Ernst,2 Larry Burd3 1Center for Emergency Medicine, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, OH, USA; 2University of North Dakota School of Medicine and Health Sciences, Grand Forks, ND, USA; 3Department of Pediatrics, North Dakota Fetal Alcohol Syndrome Center, University of North Dakota School of Medicine and Health Sciences, Grand Forks, ND, USA Background: The physiology of fetal alcohol exposure changes across gestation. Early in pregnancy placental, fetal, and amniotic fluid concentrations of alcohol exposure are equivalent. Beginning in mid-pregnancy, the maturing fetal epidermis adds keratins which decrease permeability resulting in development of a barrier between fetal circulation and the amniotic fluid. Barrier function development is essential for viability in late pregnancy and in the extra-uterine environment. In this paper we provide a selected review of the effects of barrier function on fetal alcohol exposure. Methods: We utilized a search of PubMed and Google for all years in all languages for MeSH on Demand terms: alcohol drinking, amnion, amniotic fluid, epidermis, ethanol, female, fetal development, fetus, humans, keratins, permeability, and pregnancy. We also reviewed the reference lists of relevant papers and hand-searched reference lists of textbooks for additional references. Results: By 30 gestational weeks, development of barrier function alters the pathophysiology of ethanol dispersion between the fetus and amniotic fluid. Firstly, increases in the effectiveness of barrier function decreases the rate of diffusion of alcohol from fetal circulation across fetal skin into the amniotic fluid. This reduces the volume of alcohol entering the amniotic fluid. Secondly, barrier function increases the duration of fetal exposure by decreasing the rate of alcohol diffusion from amniotic fluid back into fetal circulation. Ethanol is then transported into

  3. Unexplained fetal death

    OpenAIRE

    Sepúlveda, Janer; Quintero, Eliana Maribel

    2004-01-01

    El porcentaje de muertes fetales inexplicadas oscila entre un 21% a 50%; se define como la muerte que ocurre en fetos con edad gestacional mayor de 20 semanas o peso superior a 500 g, en la cual ni la autopsia ni el examen histológico del cordón umbilical, placenta y membranas, se logra identificar la causa. Los factores asociados con muerte fetal inexplicada son edad materna mayor de 35 años, sobrepeso, nivel educativo menor de 10 años, cigarrillo y bajo nivel socioeconómico, entre otros. La...

  4. The World Health Organization Fetal Growth Charts

    DEFF Research Database (Denmark)

    Kiserud, Torvid; Piaggio, Gilda; Carroli, Guillermo

    2017-01-01

    BACKGROUND: Perinatal mortality and morbidity continue to be major global health challenges strongly associated with prematurity and reduced fetal growth, an issue of further interest given the mounting evidence that fetal growth in general is linked to degrees of risk of common noncommunicable...... longitudinal study of fetal growth in low-risk singleton pregnancies of women of high or middle socioeconomic status and without known environmental constraints on fetal growth. Centers in ten countries (Argentina, Brazil, Democratic Republic of the Congo, Denmark, Egypt, France, Germany, India, Norway...

  5. Ascitis fetal masiva idiopática aislada

    Directory of Open Access Journals (Sweden)

    Yolimar Navarro Briceño

    2016-08-01

    Full Text Available La ascitis fetal esta comúnmente asociada a malformaciones gastrointestinales y urinarias, anemia, infección y anomalías cromosómicas. La ascitis fetal masiva idiopática es rara. Se reporta un caso de una embarazada de 33 años referida a las 17 semanas después que se detectó ascitis en ausencia de anomalías estructurales. La evaluación cardiaca y las pruebas diagnósticas de infecciones virales fueron negativas. A las 28 semanas se detectó ascitis masiva sin otros signos de hidrops fetal. La velocidad sistólica pico de la arteria cerebral media fetal estaba elevada. El Doppler de la arteria umbilical, crecimiento fetal y volumen de líquido amniótico estaban normales. El ecocardiograma fetal estaba normal. Se realizó la amniocentesis con resultados normales del cariotipo. A pesar de la persistencia de la ascitis masiva durante el seguimiento, el crecimiento fetal y el volumen de líquido amniótico eran normales con valores elevados de la velocidad sistólica pico de la arteria cerebral media fetal. A las 33 semanas la paciente se realizó cesárea de emergencia por sufrimiento fetal agudo. Se obtuvo un recién nacido vivo femenino normal con valores normales de hemoglobina al nacer. El flujo vascular hepático, vesical y hepato-portal fueron normales. La ascitis se resolvió completamente al octavo día después del nacimiento y el recién nacido fue dado de alta a los 15 días.

  6. WHO multicentre study for the development of growth standards from fetal life to childhood: the fetal component.

    Science.gov (United States)

    Merialdi, Mario; Widmer, Mariana; Gülmezoglu, Ahmet Metin; Abdel-Aleem, Hany; Bega, George; Benachi, Alexandra; Carroli, Guillermo; Cecatti, Jose Guilherme; Diemert, Anke; Gonzalez, Rogelio; Hecher, Kurt; Jensen, Lisa N; Johnsen, Synnøve L; Kiserud, Torvid; Kriplani, Alka; Lumbiganon, Pisake; Tabor, Ann; Talegawkar, Sameera A; Tshefu, Antoinette; Wojdyla, Daniel; Platt, Lawrence

    2014-05-02

    In 2006 WHO presented the infant and child growth charts suggested for universal application. However, major determinants for perinatal outcomes and postnatal growth are laid down during antenatal development. Accordingly, monitoring fetal growth in utero by ultrasonography is important both for clinical and scientific reasons. The currently used fetal growth references are derived mainly from North American and European population and may be inappropriate for international use, given possible variances in the growth rates of fetuses from different ethnic population groups. WHO has, therefore, made it a high priority to establish charts of optimal fetal growth that can be recommended worldwide. This is a multi-national study for the development of fetal growth standards for international application by assessing fetal growth in populations of different ethnic and geographic backgrounds. The study will select pregnant women of high-middle socioeconomic status with no obvious environmental constraints on growth (adequate nutritional status, non-smoking), and normal pregnancy history with no complications likely to affect fetal growth. The study will be conducted in centres from ten developing and industrialized countries: Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand. At each centre, 140 pregnant women will be recruited between 8 + 0 and 12 + 6 weeks of gestation. Subsequently, visits for fetal biometry will be scheduled at 14, 18, 24, 28, 32, 36, and 40 weeks (+/- 1 week) to be performed by trained ultrasonographers.The main outcome of the proposed study will be the development of fetal growth standards (either global or population specific) for international applications. The data from this study will be incorporated into obstetric practice and national health policies at country level in coordination with the activities presently conducted by WHO to implement the use of the Child Growth Standards.

  7. Studies on the isolation, structural analysis and tissue localization of fetal antigen 1 and its relation to a human adrenal-specific cDNA, pG2

    DEFF Research Database (Denmark)

    Jensen, Charlotte Harken; Teisner, Børge; Højrup, Peter

    1993-01-01

    Fetal antigen 1 was purified from second trimester human amniotic fluid by immunospecific affinity chromatography followed by reversed-phase chromatography. Fetal antigen 1 is a single chain glycoprotein with a M(r) of 32-38 kDa. The amino acid composition revealed a high content of cysteines......, prolines and amino acids (aa) with acidic side-chains indicating that fetal antigen 1 is a compactly folded, strongly hydrophilic molecule. The N-terminal amino acid sequence (37 aa) revealed no homology to other known protein sequences, implying that fetal antigen 1 is a 'novel' human protein. When the aa...... sequence was back-translated into the appropriate degenerate sequence of nucleic acids, fetal antigen 1 could be partially aligned to a 'human adrenal-specific mRNA, pG2'. The indirect immunoperoxidase technique demonstrated fetal antigen 1 in fetal hepatocytes, glandular cells of fetal pancreas...

  8. [The advantages of early midtrimester targeted fetal systematic organ screening for the detection of fetal anomalies--will a global change start in Israel?].

    Science.gov (United States)

    Bronshtein, Moshe; Solt, Ido; Blumenfeld, Zeev

    2014-06-01

    Despite more than three decades of universal popularity of fetal sonography as an integral part of pregnancy evaluation, there is still no unequivocal agreement regarding the optimal dating of fetal sonographic screening and the type of ultrasound (transvaginal vs abdominal). TransvaginaL systematic sonography at 14-17 weeks for fetal organ screening. The evaluation of over 72.000 early (14-17 weeks) and late (18-24 weeks) fetal ultrasonographic systematic organ screenings revealed that 96% of the malformations are detectable in the early screening with an incidence of 1:50 gestations. Only 4% of the fetal anomalies are diagnosed later in pregnancy. Over 99% of the fetal cardiac anomalies are detectable in the early screening and most of them appear in low risk gestations. Therefore, we suggest a new platform of fetal sonographic evaluation and follow-up: The extensive systematic fetal organ screening should be performed by an expert sonographer who has been trained in the detection of fetal malformations, at 14-17 weeks gestation. This examination should also include fetal cardiac echography Three additional ultrasound examinations are suggested during pregnancy: the first, performed by the patient's obstetrician at 6-7 weeks for the exclusion of ectopic pregnancy, confirmation of fetal viability, dating, assessment of chorionicity in multiple gestations, and visualization of maternal adnexae. The other two, at 22-26 and 32-34 weeks, require less training and should be performed by an obstetrician who has been qualified in the sonographic detection of fetal anomalies. The advantages of early midtrimester targeted fetal systematic organ screening for the detection of fetal anomalies may dictate a global change.

  9. Amniocentesis for fetal lung maturity: will it become obsolete?

    Science.gov (United States)

    Varner, Stephen; Sherman, Craig; Lewis, David; Owens, Sheri; Bodie, Frankie; McCathran, C Eric; Holliday, Nicolette

    2013-01-01

    AMNIOCENTESIS FOR FETAL LUNG MATURITY HAS HISTORICALLY BEEN PERFORMED FOR MANY REASONS: uterine and placental complications, maternal comorbidities, fetal issues, and even obstetric problems. Even though the risks associated with third trimester amniocentesis are extremely low, complications have been documented, including preterm labor, placental abruptions, intrauterine rupture, maternal sepsis, fetal heart rate abnormalities, and fetal-maternal hemorrhage. This review presents the types of tests for fetal lung maturity, presents the indications and tests utilized, and discusses recommendations for when amniocentesis for fetal lung maturity may be appropriate.

  10. Fetal gender determination through Y-STR analysis of maternal plasma during the third trimester of pregnancy

    Directory of Open Access Journals (Sweden)

    Hanaa M.H. Aal-Hamdan

    2015-01-01

    Conclusion: It is recommended to use Y-STR profiling as an alternative technique for fetal gender determination during the third trimester of pregnancy, in addition to its significance in forensic casework.

  11. Population differences in dysmorphic features among children with fetal alcohol spectrum disorders.

    Science.gov (United States)

    May, Philip A; Gossage, J Phillip; Smith, Matthew; Tabachnick, Barbara G; Robinson, Luther K; Manning, Melanie; Cecanti, Mauro; Jones, Kenneth Lyons; Khaole, Nathaniel; Buckley, David; Kalberg, Wendy O; Trujillo, Phyllis M; Hoyme, H Eugene

    2010-05-01

    To examine the variation in significant dysmorphic features in children from 3 different populations with the most dysmorphic forms of fetal alcohol spectrum disorders, fetal alcohol syndrome (FAS), and partial fetal alcohol syndrome (PFAS). Advanced multiple regression techniques are used to determine the discriminating physical features in the diagnosis of FAS and PFAS among children from Northern Plains Indian communities, South Africa, and Italy. Within the range of physical features used to identify children with fetal alcohol spectrum disorders, specifically FAS and PFAS, there is some significant variation in salient diagnostic features from one population to the next. Intraclass correlations in diagnostic features between these 3 populations is 0.20, indicating that about 20% of the variability in dysmorphology core features is associated with location and, therefore, specific racial/ethnic population. The highly significant diagnostic indicators present in each population are identified for the full samples of FAS, PFAS, and normals and also among children with FAS only. A multilevel model for these populations combined indicates that these variables predict dysmorphology unambiguously: small palpebral fissures, narrow vermillion, smooth philtrum, flat nasal bridge, and fifth finger clinodactyly. Long philtrum varies substantially as a predictor in the 3 populations. Predictors not significantly related to fetal alcohol spectrum disorders dysmorphology across the 3 populations are centile of height (except in Italy) strabismus, interpupilary distance, intercanthal distance, and heart murmurs. The dysmorphology associated with FAS and PFAS vary across populations, yet a particular array of common features occurs in each population, which permits a consistent diagnosis across populations.

  12. Fetal MRI of pathological brain development

    International Nuclear Information System (INIS)

    Brugger, P.C.; Prayer, D.

    2006-01-01

    Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.) [de

  13. Fetal Ultrasound

    Science.gov (United States)

    ... isn't recommended simply to determine a baby's sex. Similarly, fetal ultrasound isn't recommended solely for the purpose of producing keepsake videos or pictures. If your health care provider doesn' ...

  14. Factors Affecting Estimated Fetal Weight Measured by Ultrasound

    Directory of Open Access Journals (Sweden)

    Hasan Energin

    2016-06-01

    Full Text Available Objective: In this study, we aimed to evaluate the fac­tors that affect the accuracy of estimated fetal weight in ultrasound. Methods: This study was conducted in 3rd degree hospi­tal antenatal outpatient clinic and perinatology inpatient clinic between June 2011 and January 2012. The data were obtained from 165 pregnant women. Inclusion cri­teria were; no additional diseases, giving birth within 48 hours after ultrasound. The same physician executed all ultrasound process. Age, height, weight, obstetric history and obstetric follow –up findings were recorded. Results: Fetal gender, fetal presentation, presence of meconium in amniotic fluid, maternal parity, did not sig­nificantly affect the accuracy of fetal weight estimation by ultrasound. The mean difference between estimated fetal weight and birth weight was 104.48±84 gr in nullipars and 94.2±81 gr in multipars (p=0.44; mean difference was 98.22±79 gr in male babies and 98.15±86 gr in female babies (p=0.99. Mean difference between estimated fetal weight and birth weight was 96.92±81 gr in babies with cephalic presentation and 110.9±90 gr in babies with breech presentation (p=0.53; this difference was 95.36±79 gr in babies with amniotic fluid with meconium and 98.82± 83 gr in babies with amniotic fluid without me­conium (p=0.83. Conclusion: Fetal weight is estimation is one of key points in the obstetrician’s intrapartum managament. And it is important to make fetal weight estimation accurately. In our study, consistent with literature, we observed that fetal gender; meconium presence in amniotic fluid, fetal presentation, maternal parity does not significantly effect the accuracy of fetal weight estimation by ultrasound.

  15. Studies in Fetal Behavior: Revisited, Renewed, and Reimagined

    Science.gov (United States)

    DiPietro, Janet A.; Costigan, Kathleen A.; Voegtline, Kristin M.

    2016-01-01

    Among the earliest volumes of this Monograph series was a report by Lester Sontag and colleagues, of the esteemed Fels Institute, on the heart rate of the human fetus as an expression of the developing nervous system. Here, some 75 years later, we commemorate this work and provide historical and contemporary context on knowledge regarding fetal development, as well as results from our own research. These are based on synchronized monitoring of maternal and fetal parameters assessed between 24 and 36 weeks gestation on 740 maternal-fetal pairs compiled from eight separate longitudinal studies, which commenced in the early 1990s. Data include maternal heart rate, respiratory sinus arrhythmia, and electrodermal activity and fetal heart rate, motor activity, and their integration. Hierarchical linear modeling of developmental trajectories reveals that the fetus develops in predictable ways consistent with advancing parasympathetic regulation. Findings also include: within-fetus stability (i.e., preservation of rank ordering over time) for heart rate, motor, and coupling measures; a transitional period of decelerating development near 30 weeks gestation; sex differences in fetal heart rate measures but not in most fetal motor activity measures; modest correspondence in fetal neurodevelopment among siblings as compared to unrelated fetuses; and deviations from normative fetal development in fetuses affected by intrauterine growth restriction and other conditions. Maternal parameters also change during this period of gestation and there is evidence that fetal sex and individual variation in fetal neurobehavior influence maternal physiological processes and the local intrauterine context. Results are discussed within the framework of neuromaturation, the emergence of individual differences, and the bidirectional nature of the maternal-fetal relationship. We pose a number of open questions for future research. Although the human fetus remains just out of reach, new

  16. [THE FETAL MIDDLE CEREBRAL ARTERY PEAK SYSTOLIC VELOCITY AS A PEDICTOR OF FETAL ANEMIA IN RH-ALLOIMMUNIZED PREGNANCY].

    Science.gov (United States)

    Markov, D; Pavlova, E; Atanassova, D; Diavolov, V; Hitrova, S; Vakrilova, L; Pramatarova, T; Slancheva, B; Ivanov, St

    2015-01-01

    Rh-isoimmunization is a pathological condition in which the fetal red blood cells of a Rh (+) fetus are destroyed by the isoantibodies of a Rh (-) woman sensitized in a previous event. Despite of the wide spread implementation of anti D-gammaglobolin prophylaxis this is still the most common cause for fetal anemia. Recently, sonographic measurement of the fetal middle cerebral artery peak systolic velocity (MCA-PSV) has been shown to be an accurate non-invasive test to predict low fetal hemoglobin levels. We present a case report of Rh-alloimmunized pregnancy with moderate fetal anemia, followed-up by weekly MCA-PSV measurements. A 37-year-old Rh (-) negative gravida 3, para 1, without anti-D gammaglobolin prophylaxis in her previous pregnancies, presented at 27+0 weeks of gestation (w.g.) for a routine third trimester scan. Subsequent ultrasound measurements of MCA-PSV confirmed a progressive increase of the peak systolic velocities from 40 to 80 cm/sec, as well as a gradual rise in the anti-D titers. The evidence of developing fetal anemia necessitated elective Caesarean section performed at 35 wg. The neonate was admitted in the intensive care unit and required resuscitation, one exchange blood transfusion and several courses of phototherapy. The patient was discharged two weeks post partum. There is a strong correlation between the high peak systolic velocities in the middle cerebral artery (MCA-PSV) and the low levels of fetal hemoglobin. The high sensitivity and positive predictive value concerning the development of fetal anemia, as well as its good repeatability, makes this non-invasive test a valuable asset in the management of all pregnancies complicated by severe Rh-alloimmunization.

  17. A study on maternal-fetal attachment in pregnant women undergoing fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Concetta Polizzi

    2017-03-01

    Full Text Available Purpose: To investigate the possible effects of the fetal echocardiography experience on the prenatal attachment process. The predictive effect of specific women’s psychological variables will be explored as well.Design and methods: This between groups study involved 85 women with pregnancy at risk who underwent the fetal echocardiography, and 83 women who were about to undergo the morphological scan. The tools employed were: the Prenatal Attachment Inventory (P.A.I. to explore the maternal-fetal attachment; the Maternity Social Support Scale to investigate the woman perception of being socially supported during pregnancy; both the Big Five Questionnaire and the FACES III to explore the personality traits of pregnant women and their perception of their couple relationship functioning.Findings: The outcomes of ANOVA do not show statistically significant differences between the two groups of the mothers-to-be with regard to the scores of the P.A.I. (F = .017; p = .897; η2 = .000, while the regression analysis of the possible effect of the maternal psychological variables on the mother-fetus relationship shows a statistically significant result only with regard to the “social support” variable (r2 = .061; df = 80; p = .025.Conclusions: It would seem that the process of the prenatal attachment develops independently whether the woman has to undergo a first level screening or a second level examination such as the fetal echocardiography.

  18. Digital communication with fetal monitors.

    Science.gov (United States)

    Bozóki, Z

    1997-11-01

    Fetal heart rate (FHR) values in the averaged format that are provided by commercial computed cardiotocography analysis systems may be unsuitable for special analysis purposes. I developed a communication software program to obtain any measured values of fetal monitors for individual analysis of computed cardiotocography. The software program was used to study the data continuity of beat-to-beat FHR values as an experiment for chaos theory and power spectrum analysis. The results indicated that the signal loss was recognized at a precision of 95%. The described method of digital communication with fetal monitors was found to be useful for individual purposes in the field of computed cardiotocography analysis.

  19. A transcriptome-wide screen for mRNAs enriched in fetal Leydig cells: CRHR1 agonism stimulates rat and mouse fetal testis steroidogenesis.

    Directory of Open Access Journals (Sweden)

    Erin N McDowell

    Full Text Available Fetal testis steroidogenesis plays an important role in the reproductive development of the male fetus. While regulators of certain aspects of steroidogenesis are known, the initial driver of steroidogenesis in the human and rodent fetal testis is unclear. Through comparative analysis of rodent fetal testis microarray datasets, 54 candidate fetal Leydig cell-specific genes were identified. Fetal mouse testis interstitial expression of a subset of these genes with unknown expression (Crhr1, Gramd1b, Itih5, Vgll3, and Vsnl1 was verified by whole-mount in situ hybridization. Among the candidate fetal Leydig cell-specific factors, three receptors (CRHR1, PRLR, and PROKR2 were tested for a steroidogenic function using ex vivo fetal testes treated with receptor agonists (CRH, PRL, and PROK2. While PRL and PROK2 had no effect, CRH, at low (approximately 1 to 10 nM concentration, increased expression of the steroidogenic genes Cyp11a1, Cyp17a1, Scarb1, and Star in GD15 mouse and GD17 rat testes, and in conjunction, testosterone production was increased. Exposure of GD15 fetal mouse testis to a specific CRHR1 antagonist blunted the CRH-induced steroidogenic gene expression and testosterone responses. Similar to ex vivo rodent fetal testes, ≥ 10 nM CRH exposure of MA-10 Leydig cells increased steroidogenic pathway mRNA and progesterone levels, showing CRH can enhance steroidogenesis by directly targeting Leydig cells. Crh mRNA expression was observed in rodent fetal hypothalamus, and CRH peptide was detected in rodent amniotic fluid. Together, these data provide a resource for discovering factors controlling fetal Leydig cell biology and suggest that CRHR1 activation by CRH stimulates rat and mouse fetal Leydig cell steroidogenesis in vivo.

  20. Cholesterol synthesis by human fetal hepatocytes: effect of lipoproteins

    International Nuclear Information System (INIS)

    Carr, B.R.; Simpson, E.R.

    1984-01-01

    The purpose of the present investigation was to determine the effect of various lipoproteins on the rate of cholesterol synthesis of human fetal liver cells maintained in culture. This was accomplished by measuring the rate of incorporation of tritium from tritiated water or carbon 14-labeled acetate into cholesterol in human fetal liver cells. Optimal conditions for each assay were determined. When human fetal liver cells were maintained in the presence of low-density lipoprotein, cholesterol synthesis was inhibited in a concentration-dependent fashion. Intermediate--density lipoprotein and very-low-density lipoprotein also suppressed cholesterol synthesis in human fetal liver cells. In contrast, high-density lipoprotein stimulated cholesterol synthesis in human fetal liver cells. The results of the present as well as our previous investigations suggest that multiple interrelationships exist between fetal liver cholesterol synthesis and lipoprotein-cholesterol utilization by the human fetal adrenal gland and that these processes serve to regulate the lipoprotein-cholesterol levels in fetal plasma

  1. Fetal neonatal hyperthyroidism: diagnostic and therapeutic approachment

    Science.gov (United States)

    Kurtoğlu, Selim; Özdemir, Ahmet

    2017-01-01

    Fetal and neonatal hyperthyroidism may occur in mothers with Graves’ disease. Fetal thyrotoxicosis manifestation is observed with the transition of TSH receptor stimulating antibodies to the fetus from the 17th–20th weeks of pregnancy and with the fetal TSH receptors becoming responsive after 20 weeks. The diagnosis is confirmed by fetal tachycardia, goiter and bone age advancement in pregnancy and maternal treatment is conducted in accordance. The probability of neonatal hyperthyroidism is high in the babies of mothers that have ongoing antithyroid requirement and higher antibody levels in the last months of pregnancy. Clinical manifestation may be delayed by 7–17 days because of the antithyroid drugs taken by the mother. Neonatal hyperthyroidism symptoms can be confused with sepsis and congenital viral infections. Herein, the diagnosis and therapeutic approach are reviewed in cases of fetal neonatal hyperthyroidism. PMID:28439194

  2. Births and deaths including fetal deaths

    Data.gov (United States)

    U.S. Department of Health & Human Services — Access to a variety of United States birth and death files including fetal deaths: Birth Files, 1968-2009; 1995-2005; Fetal death file, 1982-2005; Mortality files,...

  3. Prenatal smoking exposure and asymmetric fetal growth restriction

    NARCIS (Netherlands)

    Delpisheh, Ali; Brabin, Loretta; Drummond, Sandra; Brabin, Bernard J.

    2008-01-01

    Background: Prenatal smoking exposure causes intrauterine fetal growth restriction ( IUGR), although its effects on fetal proportionality are less clearly defined. Aim: The present study assessed fetal proportionality in babies with IUGR using maternal salivary cotinine to indicate maternal smoking

  4. The origin of fetal sterols in second-trimester amniotic fluid : endogenous synthesis or maternal-fetal transport?

    NARCIS (Netherlands)

    Baardman, Maria E.; Erwich, Jan Jaap H. M.; Berger, Rolf M. F.; Hofstra, Robert M. W.; Kerstjens-Frederikse, Wilhelmina S.; Luetjohann, Dieter; Plosch, Torsten; Lutjohann, D.

    OBJECTIVE: Cholesterol is crucial for fetal development. To gain more insight into the origin of the fetal cholesterol pool in early human pregnancy, we determined cholesterol and its precursors in the amniotic fluid of uncomplicated, singleton human pregnancies. STUDY DESIGN: Total sterols were

  5. Maternal-fetal hepatic and placental metabolome profiles are associated with reduced fetal growth in a rat model of maternal obesity

    DEFF Research Database (Denmark)

    Mumme, Karen; Gray, Clint; Reynolds, Clare M.

    2016-01-01

    : Metabolomic profiling was used to reveal altered maternal and fetal metabolic pathways in a model of diet induced obesity during pregnancy, leading to reduced fetal growth. Methods: We examined the metabolome of maternal and fetal livers, and placenta following a high fat and salt intake. Sprague–Dawley rats...

  6. Assessment of fetal activity concentration and fetal dose for selected radionuclides based on animal and human data

    International Nuclear Information System (INIS)

    Roedler, H.D.

    1987-01-01

    Biokinetic data of selected radionuclide compounds from investigations in man and animal were taken from literature references with the purpose to provide a basis for a comparative assessment of fetal and adult radiation doses after intake or administration of radionuclides. The following ratios of fetal to adult doses were derived from human data: 0.5 for caesium 137 and total body, 2.3 for iron 59 and liver, 0.06 - 0.3 - 1.1 for iodine 131 and thyroid, and 0.1 - 0.3 for strontium 90 and bone. The ratios of activity concentrations in fetal and adult tissues are of considerable variability - up to three orders of magnitude. Further studies on fetal and adult biokinetics specifically designed for comparative dose assessment are indispensable. 106 refs.; 6 tabs

  7. Noninvasive fetal QRS detection using an echo state network and dynamic programming.

    Science.gov (United States)

    Lukoševičius, Mantas; Marozas, Vaidotas

    2014-08-01

    We address a classical fetal QRS detection problem from abdominal ECG recordings with a data-driven statistical machine learning approach. Our goal is to have a powerful, yet conceptually clean, solution. There are two novel key components at the heart of our approach: an echo state recurrent neural network that is trained to indicate fetal QRS complexes, and several increasingly sophisticated versions of statistics-based dynamic programming algorithms, which are derived from and rooted in probability theory. We also employ a standard technique for preprocessing and removing maternal ECG complexes from the signals, but do not take this as the main focus of this work. The proposed approach is quite generic and can be extended to other types of signals and annotations. Open-source code is provided.

  8. Fetal Heart Rate Monitoring during Labor

    Science.gov (United States)

    ... What are the types of monitoring? • How is auscultation performed? • How is electronic fetal monitoring performed? • How ... methods of fetal heart rate monitoring in labor. Auscultation is a method of periodically listening to the ...

  9. Prognostic value of three-dimensional ultrasound for fetal hydronephrosis

    Science.gov (United States)

    WANG, JUNMEI; YING, WEIWEN; TANG, DAXING; YANG, LIMING; LIU, DONGSHENG; LIU, YUANHUI; PAN, JIAOE; XIE, XING

    2015-01-01

    The present study evaluated the prognostic value of three-dimensional ultrasound for fetal hydronephrosis. Pregnant females with fetal hydronephrosis were enrolled and a novel three-dimensional ultrasound indicator, renal parenchymal volume/kidney volume, was introduced to predict the postnatal prognosis of fetal hydronephrosis in comparison with commonly used ultrasound indicators. All ultrasound indicators of fetal hydronephrosis could predict whether postnatal surgery was required for fetal hydronephrosis; however, the predictive performance of renal parenchymal volume/kidney volume measurements as an individual indicator was the highest. In conclusion, ultrasound is important in predicting whether postnatal surgery is required for fetal hydronephrosis, and the three-dimensional ultrasound indicator renal parenchymal volume/kidney volume has a high predictive performance. Furthermore, the majority of cases of fetal hydronephrosis spontaneously regress subsequent to birth, and the regression time is closely associated with ultrasound indicators. PMID:25667626

  10. The effect of Ramadan fasting on fetal development.

    Science.gov (United States)

    Karateke, Atilla; Kaplanoglu, Mustafa; Avci, Fazil; Kurt, Raziye Keskin; Baloglu, Ali

    2015-01-01

    To evaluate the effects of Ramadan fasting on fetal development and outcomes of pregnancy. We performed this study in Antakya State Hospital of Obstetrics and Child Care, between 28 June 2014 and 27 July 2014 (during the month of Ramadan). A total of two hundred forty healthy pregnant women who were fasting during Ramadan, were included in the groups. The three groups were divided according to the trimesters. The each group was consisted of 40 healthy pregnant women with fasting and 40 healthy pregnant women without fasting. For evaluating the effects of Ramadan on fetus, ultrasonography was performed on all pregnant women in the beginning and the end of Ramadan. We used the essential parameters for the following measurements: increase of fetal biparietal diameter (BPD), increase of fetal femur length (FL), increase of estimated fetal body weight (EFBW), fetal biophysical profile (BPP), amniotic fluid index (AFI), and umbilical artery systole/diastole (S/D) ratio. No significant difference was found between the two groups for the fetal age, maternal weight gain (kilogram), estimated fetal weight gain (EFWG), fetal BPP, AFI, and umbilical artery S/D ratio. On the other hand, a statistically significant increase was observed in maternal weight in the second and third trimesters and a significant increase was observed in the amniotic fluid index in second trimester. In Ramadan there was no bad fetal outcome between pregnant women with fasting and pregnant women without fasting. Pregnant women who want to be with fast, should be examined by doctors, adequately get breakfast before starting to fast and after the fasting take essential calori and hydration. More comprehensive randomized studies are needed to explain the effects of fasting on the pregnancy and fetal outcomes.

  11. Maternal exposure to hurricane destruction and fetal mortality.

    Science.gov (United States)

    Zahran, Sammy; Breunig, Ian M; Link, Bruce G; Snodgrass, Jeffrey G; Weiler, Stephan; Mielke, Howard W

    2014-08-01

    The majority of research documenting the public health impacts of natural disasters focuses on the well-being of adults and their living children. Negative effects may also occur in the unborn, exposed to disaster stressors when critical organ systems are developing and when the consequences of exposure are large. We exploit spatial and temporal variation in hurricane behaviour as a quasi-experimental design to assess whether fetal death is dose-responsive in the extent of hurricane damage. Data on births and fetal deaths are merged with Parish-level housing wreckage data. Fetal outcomes are regressed on housing wreckage adjusting for the maternal, fetal, placental and other risk factors. The average causal effect of maternal exposure to hurricane destruction is captured by difference-in-differences analyses. The adjusted odds of fetal death are 1.40 (1.07-1.83) and 2.37 (1.684-3.327) times higher in parishes suffering 10-50% and >50% wreckage to housing stock, respectively. For every 1% increase in the destruction of housing stock, we observe a 1.7% (1.1-2.4%) increase in fetal death. Of the 410 officially recorded fetal deaths in these parishes, between 117 and 205 may be attributable to hurricane destruction and postdisaster disorder. The estimated fetal death toll is 17.4-30.6% of the human death toll. The destruction caused by Hurricanes Katrina and Rita imposed significant measurable losses in terms of fetal death. Postdisaster migratory dynamics suggest that the reported effects of maternal exposure to hurricane destruction on fetal death may be conservative. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Fatores de risco maternos associados à acidose fetal Maternal risk factors associated with fetal acidosis

    Directory of Open Access Journals (Sweden)

    José Mauro Madi

    2010-09-01

    Full Text Available OBJETIVOS: avaliar os fatores de risco maternos associados à acidose fetal. MÉTODOS: estudo tipo caso-controle composto por 188 recém-nascidos, sendo que 47 compuseram o grupo casos (pH de artéria umbilical OBJECTIVES: to assess maternal risk factors associated with fetal acidosis. METHODS: a case-control type study was conducted of 188 neonates, of whom 47 comprised the case group (umbilical arterial pH <7.0 and 141 the control (umbilical arterial pH E7.1 <7.3. The study included only single-gestation neonates without congenital malformations. Both maternal and fetal variables were taken into consideration. Statistical analysis involved the calculation of the raw and adjusted Odds Ratio, Student's t-test, the chi-squared test and multivariate analysis using Enter-method non-conditional logistic regression. The level of statistical significance was set at p<0.05. RESULTS: in the case group higher percentages of caesarian sections and pre-term births were observed, involving almost five times as much intensive care and twenty-five times more likelihood of Apgar in the 5th minute <7. No association was observed between the groups and fetal presentation, mother's age, history of miscarriage, years of schooling of mother or attendance at prenatal sessions. After multivariate analysis, the only risk factors that remained significant were complications relating to the placenta or the umbilical cord. Deliveries involving complications relating to the placenta or the umbilical cord were three times more likely to involve fetal acidemia. CONCLUSIONS: acidemia among neonates was associated with a higher percentage of caesarians, premature births, a need for intensive care and treatment and an Apgar index of <7 in the 5th minute. After multivariate analysis, complications relating to premature displacement of the placenta and the umbilical cord were the only remaining risk factors associated with fetal acidemia.

  13. Influence of Infection During Pregnancy on Fetal Development

    Science.gov (United States)

    Adams Waldorf, Kristina M.; McAdams, Ryan M.

    2014-01-01

    Infection by bacteria, viruses and parasites may lead to fetal death, organ injury or limited sequelae depending on the pathogen. Here we consider the role of infection during pregnancy on fetal development including placental development and function, which can lead to fetal growth restriction. The classic group of teratogenic pathogens are referred to as “TORCH” (Toxoplasma gondii, Others like Treponema pallidum, Rubella virus, Cytomegalovirus, Herpes simplex virus), but should include a much broader group of pathogens including Parvovirus B19, Varicella zoster virus, and Plasmodium falciparum to name a few. In this review, we describe the influence of different infections in utero on fetal development and the short- and long-term outcomes for the neonate. In some cases, the mechanisms used by these pathogens to disrupt fetal development are well known. Bacterial infection of the developing fetal lungs and brain begins with inflammatory cascade resulting in cytokine injury and oxidative stress. For some pathogens like P. falciparum, the mechanisms involve oxidative stress and apoptosis to disrupt placental and fetal growth. An in utero infection may also impact the long-term health of the infant; in many cases, a viral infection in utero increases the risk of developing Type 1 diabetes in childhood. Understanding the varied mechanisms employed by these pathogens may enable therapies to attenuate changes in fetal development, decrease preterm birth, and improve survival. PMID:23884862

  14. INTRAUTERINE FETAL DEATH CASES AT TERTIARY CENTER

    Directory of Open Access Journals (Sweden)

    Babu Lal Bishnoi

    2018-01-01

    Full Text Available BACKGROUND Intrauterine fetal death is a tragic event for the parents and a great cause of stress for the caregiver. It is an important indicator of maternal and perinatal health of a given population. This study was undertaken to study the maternal and fetal factors associated with intrauterine fetal death. Aim and Objective- This was an Analytical study aimed to evaluate and understand the prevalence, socio-epidemiological and etiological factors of IUFD methodology should not be mixed with aims and objectives MATERIALS AND METHODS The study was carried out at March 2017 to June 2017 (4 months study which was conducted at Dr. S. N. Medical College, Jodhpur, Rajasthan. The details were entered in a preformed proforma. IUD is defined as fetal death beyond 20 weeks of gestation and/or birth weight >500g. The details of complaints at admission, obstetrics history, menstrual history, examination findings, per vaginal examination findings, mode and method of delivery and fetal outcomes and investigation reports were recorded. RESULTS A total of 227 intrauterine fetal deaths were reported amongst 6264 deliveries conducted during the study period. The incidence rate of intrauterine fetal death was 36/1000 live births. 192 (84.56% deliveries were unbooked and unsupervised and 133 (58.59% belonged to rural population and 126 (55.5% were preterm and 221 (97.55% were singleton pregnancy. Among the identifiable causes hypertensive disorders (24.22% and severe anemia (13.10% were most common followed by placental causes (9.97%. Congenital malformations were responsible for 12.39% and unidentifiable causes were 11.01%. Induction was done in 103 patients, 94 patients had spontaneous onset of labour and caesarean section was done in 30 patients. Incidence of intrauterine foetal demise gradually decreased as parity advanced. CONCLUSION Institutional deliveries should be promoted to prevent intrapartum fetal deaths. Decrease in the incidence of IUD would

  15. Fetal Macrosomia

    Science.gov (United States)

    ... re more likely to have a large baby. Maternal obesity. Fetal macrosomia is more likely if you're ... is more likely to be a result of maternal diabetes, obesity or weight gain during pregnancy than other causes. ...

  16. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10 -5 Gy) per 1,000 mR (258 μC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicists who can make the calculations immediately

  17. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10(-5) Gy) per 1,000 mR (258 microC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicians who can make the calculations immediately

  18. Recommendations for fetal echocardiography in twin pregnancy in 2016

    Directory of Open Access Journals (Sweden)

    Leszczyńska Katarzyna

    2016-01-01

    Full Text Available Progress in the fields of fetal cardiology and fetal surgery have been seen not only in singleton pregnancies but also in multiple pregnancies. Proper interpretation of prenatal echocardiography is critical to clinical decision making, family counseling and perinatal management for obstetricians, maternal fetal medicine specialists, neonatologists and pediatric cardiologists. Fetal echocardiography is one of the most challenging and time-consuming prenatal examinations to perform, especially in multiple gestations. Performing just the basic fetal exam in twin gestations may take an hour or more. Thus, it is not practical to perform this exam in all cases of multiple gestations. Therefore our review and recommendations are related to fetal echocardiography in twin gestation.

  19. Atrial natriuretic factor in maternal and fetal sheep

    International Nuclear Information System (INIS)

    Cheung, C.Y.; Gibbs, D.M.; Brace, R.A.

    1987-01-01

    To determine atrial natriuretic factor (ANF) concentrations in the circulation and body fluids of adult pregnant sheep and their fetuses, pregnant ewes were anesthetized with pentobarbital sodium, and the fetuses were exteriorized for sampling. ANF concentration, as measured by radioimmunoassay, was 47 +/- 6 (SE) pg/ml in maternal plasma, which was significantly higher than the 15 +/- 3 pg/ml in maternal urine. In the fetus, plasma ANF concentration was 265 +/- 49 pg/ml, 5.6 times that in maternal plasma. No umbilical arterial and venous difference in ANF concentration was observed. Fetal urine ANF concentration was significantly lower than that in fetal plasma, and was similar to that measured in amniotic and allantoic fluid. In chronically catheterized maternal and fetal sheep, fetal plasma ANF was again 5.1 times that in maternal plasma, and these levels were not different from those measured in acutely anesthetized animals. These results demonstrate that immunoreactive ANF is present in the fetal circulation at levels higher than those found in the mother. The low concentration of ANF in fetal urine suggests that ANF is probably metabolized and/or reabsorbed by the fetal kidney

  20. Hypoxia: From Placental Development to Fetal Programming.

    Science.gov (United States)

    Fajersztajn, Lais; Veras, Mariana Matera

    2017-10-16

    Hypoxia may influence normal and different pathological processes. Low oxygenation activates a variety of responses, many of them regulated by hypoxia-inducible factor 1 complex, which is mostly involved in cellular control of O 2 consumption and delivery, inhibition of growth and development, and promotion of anaerobic metabolism. Hypoxia plays a significant physiological role in fetal development; it is involved in different embryonic processes, for example, placentation, angiogenesis, and hematopoiesis. More recently, fetal hypoxia has been associated directly or indirectly with fetal programming of heart, brain, and kidney function and metabolism in adulthood. In this review, the role of hypoxia in fetal development, placentation, and fetal programming is summarized. Hypoxia is a basic mechanism involved in different pregnancy disorders and fetal health developmental complications. Although there are scientific data showing that hypoxia mediates changes in the growth trajectory of the fetus, modulates gene expression by epigenetic mechanisms, and determines the health status later in adulthood, more mechanistic studies are needed. Furthermore, if we consider that intrauterine hypoxia is not a rare event, and can be a consequence of unavoidable exposures to air pollution, nutritional deficiencies, obesity, and other very common conditions (drug addiction and stress), the health of future generations may be damaged and the incidence of some diseases will markedly increase as a consequence of disturbed fetal programming. Birth Defects Research 109:1377-1385, 2017.© 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  1. Gestational Age Estimation Based on Fetal Pelvimetry on Fetal Ultrasound in Iraqi Women

    Directory of Open Access Journals (Sweden)

    Sattar Razzaq Al-Esawi

    2016-08-01

    Full Text Available Ultrasound is an integral part of obstetric practice, and assessment of gestational age (GA is a central element of obstetric ultrasonography. Sonographic estimation of GA is derived from calculations based on fetal measurements. Numerous equations for GA calculation from fetal biometry have been adopted in routine practice. This study reports a new method of estimating GA in the second and third trimester using interischial distance (IID, the distance between the two ischial primary ossification centers, on fetal ultrasound. Four hundred women with uncomplicated normal singleton pregnancies from 16 weeks to term were examined. Standard fetal obstetric ultrasound was done measuring biparietal diameter (BPD and femur length (FL for each fetus. The IID, in millimeters, was correlated with the GA in weeks based upon the BPD and FL individually, and the BPD and FL together. Statistical analysis showed strong correlation between the IID and GA calculated from the FL with correlation coefficient (r =0.989, P < 0.001. Strong linear correlation was also found between the IID and GA based upon BPD and BPD+FL. Further statistical analysis using regression equations also showed that the IID was slightly wider in female fetuses, but this difference was not statistically significant. Resulting from this analysis, we have arrived at an easy-to-use equation: GA Weeks = (IID mm + 8 ±1 week. We feel this method can be especially applicable in the developing world, where midwives may not have access to software for fetal biometry in their basic handheld ultrasound machines. Even more sophisticated machines may not come with loaded software for obstetrics analysis. There are several limitations to this study, discussed below. We recommend further studies correlating the IID with other biometric parameters.

  2. Fetal programming as a predictor of adult health or disease: the need to reevaluate fetal heart function.

    Science.gov (United States)

    Miranda, Joana O; Ramalho, Carla; Henriques-Coelho, Tiago; Areias, José Carlos

    2017-11-01

    Epidemiologic and experimental evidence suggests that adverse stimuli during critical periods in utero permanently alters organ structure and function and may have persistent consequences for the long-term health of the offspring. Fetal hypoxia, maternal malnutrition, or ventricular overloading are among the major adverse conditions that can compromise cardiovascular development in early life. With the heart as a central organ in fetal adaptive mechanisms, a deeper understanding of the fetal cardiovascular physiology and of the echocardiographic tools to assess both normal and stressed pregnancies would give precious information on fetal well-being and hopefully may help in early identification of special risk groups for cardiovascular diseases later in life. Assessment of cardiac function in the fetus represents an additional challenge when comparing to children and adults, requiring advanced training and a critical approach to properly acquire and interpret functional parameters. This review summarizes the basic fetal cardiovascular physiology and the main differences from the mature postnatal circulation, provides an overview of the particularities of echocardiographic evaluation in the fetus, and finally proposes an integrated view of in utero programming of cardiovascular diseases later in life, highlighting priorities for future clinical research.

  3. Hormonal influences on growth of the fetal pig

    International Nuclear Information System (INIS)

    Spencer, G.S.

    1986-01-01

    Although there is considerable information on hormonal systems regulating growth postnatally, little is known about hormonal influences on growth in the fetuw. It has long been postulated that insulin is the major fetal growth promoting hormone. However, chronic administration of insulin to the fetal pig during 14 days in utero, although producing hyperinsulinaemia and elevated somatomedin levels, did not stimulate an increase in length, weight or cell number. Postnatally the principal growth promoting hormones are the growth hormone dependent somatomedins. It is thought that multiplication stimulating activity (MSA) is the fetal somatomedin. However, under similar conditions to those used for insulin administration, MSA did not affect growth in the fetal pig. Administration of somatostatin to chronically catheterized fetuses inhibited (p≤0.01) and thyrotrophin releasing factor stimulated (≤0.01) GH release. However, chronic administration of SRIF did not inhibit fetal growth. Thus there does seem to be some hypothalamic control over GH secretion but this may not play a major role in regulating fetal growth

  4. Occupational lifting, fetal death and preterm birth

    DEFF Research Database (Denmark)

    Mocevic, Emina; Svendsen, Susanne Wulff; Jørgensen, Kristian Tore

    2014-01-01

    OBJECTIVE: We examined the association between occupational lifting during pregnancy and risk of fetal death and preterm birth using a job exposure matrix (JEM). METHODS: For 68,086 occupationally active women in the Danish National Birth Cohort, interview information on occupational lifting...... the JEM. We used Cox regression models with gestational age as underlying time variable and adjustment for covariates. RESULTS: We observed 2,717 fetal deaths and 3,128 preterm births within the study cohort. No exposure-response relation was observed for fetal death, but for women with a prior fetal...... death, we found a hazard ratio (HR) of 2.87 (95% CI 1.37, 6.01) for stillbirth (fetal death ≥22 completed gestational weeks) among those who lifted >200 kg/day. For preterm birth, we found an exposure-response relation for primigravid women, reaching a HR of 1.43 (95% CI 1.13, 1.80) for total loads >200...

  5. Sonographic large fetal head circumference and risk of cesarean delivery.

    Science.gov (United States)

    Lipschuetz, Michal; Cohen, Sarah M; Israel, Ariel; Baron, Joel; Porat, Shay; Valsky, Dan V; Yagel, Oren; Amsalem, Hagai; Kabiri, Doron; Gilboa, Yinon; Sivan, Eyal; Unger, Ron; Schiff, Eyal; Hershkovitz, Reli; Yagel, Simcha

    2018-03-01

    Persistently high rates of cesarean deliveries are cause for concern for physicians, patients, and health systems. Prelabor assessment might be refined by identifying factors that help predict an individual patient's risk of cesarean delivery. Such factors may contribute to patient safety and satisfaction as well as health system planning and resource allocation. In an earlier study, neonatal head circumference was shown to be more strongly associated with delivery mode and other outcome measures than neonatal birthweight. In the present study we aimed to evaluate the association of sonographically measured fetal head circumference measured within 1 week of delivery with delivery mode. This was a multicenter electronic medical record-based study of birth outcomes of primiparous women with term (37-42 weeks) singleton fetuses presenting for ultrasound with fetal biometry within 1 week of delivery. Fetal head circumference and estimated fetal weight were correlated with maternal background, obstetric, and neonatal outcome parameters. Elective cesarean deliveries were excluded. Multinomial regression analysis provided adjusted odds ratios for instrumental delivery and unplanned cesarean delivery when the fetal head circumference was ≥35 cm or estimated fetal weight ≥3900 g, while controlling for possible confounders. In all, 11,500 cases were collected; 906 elective cesarean deliveries were excluded. A fetal head circumference ≥35 cm increased the risk for unplanned cesarean delivery: 174 fetuses with fetal head circumference ≥35 cm (32%) were delivered by cesarean, vs 1712 (17%) when fetal head circumference cesarean delivery by an adjusted odds ratio of 1.75 (95% confidence interval, 1.4-2.18) controlling for gestational age, fetal gender, and epidural anesthesia. The rate of prolonged second stage of labor was significantly increased when either the fetal head circumference was ≥35 cm or the estimated fetal weight ≥3900 g, from 22.7% in the total

  6. The Danish Fetal Medicine Database

    DEFF Research Database (Denmark)

    Ekelund, Charlotte K; Petersen, Olav B; Jørgensen, Finn S

    2015-01-01

    OBJECTIVE: To describe the establishment and organization of the Danish Fetal Medicine Database and to report national results of first-trimester combined screening for trisomy 21 in the 5-year period 2008-2012. DESIGN: National register study using prospectively collected first-trimester screening...... data from the Danish Fetal Medicine Database. POPULATION: Pregnant women in Denmark undergoing first-trimester screening for trisomy 21. METHODS: Data on maternal characteristics, biochemical and ultrasonic markers are continuously sent electronically from local fetal medicine databases (Astraia Gmbh...... software) to a central national database. Data are linked to outcome data from the National Birth Register, the National Patient Register and the National Cytogenetic Register via the mother's unique personal registration number. First-trimester screening data from 2008 to 2012 were retrieved. MAIN OUTCOME...

  7. Fetal MRI and ultrasound of congenital CNS anomalies; Fetales MRT und Ultraschall der angeborenen ZNS-Fehlbildungen

    Energy Technology Data Exchange (ETDEWEB)

    Pogledic, I.; Reith, W. [Universitaetsklinikum des Saarlandes, Homburg/Saar, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany); Meyberg-Solomayer, G. [Universitaetsklinikum des Saarlandes, Homburg/Saar, Klinik fuer Frauenheilkunde, Geburtsheilkunde und Reproduktionsmedizin, Homburg/Saar (Germany)

    2013-02-15

    In the last decade the newest technologies, fetal magnetic resonance imaging (MRI) and 3D ultrasound, have given an insight into the minute structures of the fetal brain. However, without knowledge of the basic developmental processes the imaging is futile. Knowledge of fetal neuroanatomy corresponding to the gestational week is necessary in order to recognize pathological structures. Furthermore, a modern neuroradiologist should be acquainted with the three steps in the formation of the cerebral cortex: proliferation, migration and differentiation of neurons in order to be in a position to suspect that there is a pathology and start recognizing and discovering the abnormalities. The fetal MRI has become an important complementary method to ultrasound especially in cortical malformations when confirmation of the prenatal diagnosis is needed and additional pathologies need to be diagnosed. In this manner these two methods help in parental counseling and treatment planning. (orig.) [German] Dank neuer Technologien (z. B. fetale MRT, 3-D-Sonographie) ist es moeglich, kleinste Hirnstrukturen darzustellen. Ohne Kenntnisse der grundlegenden Entwicklungsprozesse des Gehirns waere die Bildgebung jedoch sinnlos. Um pathologische Veraenderungen zu erkennen, ist es notwendig, den Stand der fetalen Neuroanatomie in der entsprechenden Schwangerschaftswoche zu kennen. Heutzutage sollte sich ein Neuroradiologe mit den 3 Schritten der kortikalen Entwicklung - Proliferation, Migration und Differenzierung der Neuronen - vertraut machen. Nur dann wird er in der Lage sein, pathologische Veraenderungen in Betracht zu ziehen, bzw. diese zu erkennen. Die fetale MRT ist besonders wichtig, ergaenzend zur zerebralen Sonographie, zur Diagnosebestaetigung bei kortikalen Veraenderungen und Nachweis weiterer Pathologien. In dieser Kombination ermoeglichen diese Methoden eine adaequate Beratung der Eltern und Planung der Behandlung. (orig.)

  8. Percepção materna de movimentos fetais como método de avaliação da vitalidade fetal em gestantes diabéticas Maternal perception of fetal movements as a method to evaluate fetal condition in diabetic women

    Directory of Open Access Journals (Sweden)

    Belmiro Gonçalves Pereira

    1999-12-01

    Full Text Available Objetivo: avaliar a acurácia da percepção materna dos movimentos fetais (PMMF na predição de alguns resultados perinatais em gestantes diabéticas. Métodos: análise retrospectiva de 209 gestantes diabéticas atendidas no Centro de Atenção Integral à Saúde da Mulher (CAISM, entre junho de 1988 e maio de 1996, que tinham registro de PMMF dentro dos três dias anteriores ao parto, monitorização eletrônica da freqüência cardíaca fetal intraparto, idade gestacional > ou = 30 semanas, avaliação do recém-nascido (RN e diagnóstico neonatal. O teste de PMMF foi considerado normal quando a mulher detectou um mínimo de 7 movimentos em 60 minutos. Resultados: a sensibilidade do teste foi de 23 e 29% para Apgar Purpose: to evaluate the accuracy of maternal perception of fetal movements (MPFM in diabetic pregnant women, using Apgar score at the 1st and 5th min of life, intrapartum fetal distress and neonatal hypoxia as parameters. Methods: two hundred and nine diabetic women evaluated at the High Risk Prenatal Care Clinic of the Women's Hospital (CAISM were analyzed retrospectively between June 1988 and May 1996. All patients had MPFM records within three days before delivery, fetal heart rate recordings during labor, gestational age greater than 30 weeks and a complete neonatal evaluation. MPFM was classified as normal if seven movements were recorded in 60 min. Results: the sensitivity of the test was 23 and 29% for Apgar score 7 at 5 min and neonatal hypoxia. Conclusions: MPFM is a useful test to identify diabetic women needing fetal evaluation with more complex techniques, given the high NPV, that indicates the capacity to separate the cases where the fetus is in good condition.

  9. Prenatal diagnostic evaluation of fetal ventricular dilatation by MRI

    International Nuclear Information System (INIS)

    Kawabata, Ichiro; Tamaya, Teruhiko; Iwata, Tatsuo; Ando, Takashi; Yamada, Hiromu

    1992-01-01

    Recent advances in MRI have contributed to the antenatal confirmatory diagnosis of fetal anomalies, especially in the fetal brain and central nervous system. In this study, eight infants with fetal ventricular dilatation, suggested by prenatal ultrasonography, were evaluated with confirmatory diagnosis by MRI (SIGNA; General Electric Company, 1.5 tesla). These anomalies were demonstrated at 19 to 36 weeks by ultrasonography. One of the eight died in utero at 22 weeks of gestation, another one day after birth (33 weeks of gestation). Two were delivered by Cesarean section. It has been proved that clear and effective images can be obtained by mother's walking without sedative drugs. Fetal MRI gave clear images not only in fetal horizontal section, but also in sagittal section, which is usually difficult to obtain by ultrasonography. Confirmatory diagnosis of eight cases were obtained by MRI. Fetal MRI can provide an effective prenatal diagnosis, especially in cases of fetal brain anomaly, even when compared with postnatal CT findings. (author)

  10. A means for fetal monitoring and reducing stillbirth

    African Journals Online (AJOL)

    2013-11-25

    Nov 25, 2013 ... Nigerian Journal of Clinical Practice • Jul-Aug 2014 • Vol 17 • Issue 4 ... perceived alteration in regular fetal movement after the age of viability may signify impending adverse ... alarm signal” (MAS) – absent fetal movement for a duration ... excessive fetal movement especially in low‑income countries.

  11. Quaternary structure and spin state of human fetal methemoglobin

    International Nuclear Information System (INIS)

    Chevion, M.; Navok, T.; Ilan, Y.A.; Czapski, G.

    1981-01-01

    Using the pulse-radiolysis technique, solutions of fetal human methemoglobin were irradiated in order to reduce a single heme-iron within the protein tetramers. The valence-hybrids thus formed ere reacted wjth oxygen. Kinetics of the reactions were studied. The effects of p and inositol-hexaphosphate (IHP) were examined. The kinetics of the ligation of oxygen to stripped valence-hybrids showed a single-phase behaviour at the pH range 7-9. As the pH was lowered below 6.5, a second slower phase became apparent. This slow phase consisted of approximately 50% at pH 5.8. In the presence of IHP above pH 7.4, the kinetics of oxygen-binding was of a single-phase. As the pH was lowered a transition to a second, slower phase was noticed. Below pH 7 the slower phase was the only detectable one. The analysis of the relative contribution of the faster phase to the total reaction, as a function of the pH, showed a typical sigmoidal transition curve characterized by a pK = 7.2 and a Hill parameter n = 3.06. On this basis it is concluded that stripped, fetal human methemoglobin resides in an R quaternary structure while the presence of IHP stabilizes the T structure at pH below 7.2. The switch between the high spin aquomet- and the low spin hydroxymet-derivatives of adult and fetal human hemoglobins was studied optically in detail. These switches were found to be only slightly affected by IHP, and exhibited very low cooperativity (pK = 8.04; n = 1.1 and pK = 8.10; n = 1.3 for adult methemoglobin when stripped and in the presence of IHP, respectively; pK = 8.18; n = 1.11 and pK = 8.21; n = 1.28 for fetal methemoglobin when stripped and in the presence of IHP, respectively). These findings lead to the conclusion that the transition between quaternary structures in either human or fetal methemoglobins is not coupled to the switch of the spin state of the ferric heme. (author)

  12. Bloqueio AV total congênito: novo modelo experimental para avaliação do marcapasso fetal Fetal heart block: a new experimental model to assess fetal pacing

    Directory of Open Access Journals (Sweden)

    Renato S Assad

    1994-09-01

    Full Text Available O implante de marcapasso epicárdíco em fetos via toracotomia é um procedimento potencialmente mais seguro e eficaz para se tratar o bloqueio AV total congênito (BAVT, quando associado à hidropsia fetal e refratário ao tratamento clínico. Este estudo foi desenvolvido com o objetivo de avaliar as características eletrofisiológicas de dois eletrodos epicárdicos através de novo modelo experimental de BAVT congênito induzido pela crioablação do nó AV. Foram aplicados, em 2 grupos de 6 fetos de ovelhas (80% da gestação, um eletrodo de rosqueamento (1,5 voltas e outro de sutura epicárdica. O BAVT foi obtido em todos os fetos, não sendo observado nenhum ritmo de escape ventricular. Os limiares de estimulação foram baixos para ambos os eletrodos, com valores inferiores para o eletrodo de rosqueamento com largura de pulso abaixo de 0,9 mseg (p 0,20 na amplitude da onda R dos 2 eletrodos. O slew rate foi significativamente maior para o grupo de fetos com eletrodo de rosqueamento (1,40 ± 0,2 versus 0,62 ± 0,2 V/seg. p=0,04. O método é simples e reprodutível para avaliação do marcapasso fetal, sendo que o eletrodo de rosqueamento representa a melhor opção, quando houver indicação de implante de marcapasso em fetos.Epicardial fetal pacing via thoracotomy has the potential for being a safer and more reliable procedure to treat congenital complete heart block (CHB associated with fetal hydrops refractory to medical therapy. To assess the acute electrophysiologic characteristics of two ventricular epicardial leads, a new experimental model of fetal heart block induced by cryosurgical ablation of the AV node without the need for fetal cardiac bypass was performed in 12 pregnant ewes at 110-115 days of gestation. A modified screw-in lead (one and a half turn was used in 6 fetal lambs and a stitch-on lead in the other 6 lambs. CHB was achieved in 100% of the fetal lambs, with no ventricular escape rate noticed in any of the lambs

  13. Distribution of melatonin receptor in human fetal brain

    Institute of Scientific and Technical Information of China (English)

    WANG Guo-quan; SHAO Fu-yuan; ZHAO Ying; LIU Zhi-min

    2001-01-01

    Objective: To study the distribution of 2 kinds of melatonin receptor subtypes (mtl and MT2) in human fetal brain. Methods: The fetal brain tissues were sliced and the distribution ofmelatonin receptors in human fetal brain were detected using immunohistochemistry and in situ hybridization. Results: Melatonin receptor mtl existed in the cerebellun and hypothalamus, melatonin receptor MT2 exists in hypothalamus, occipital and medulla. Conclusion: Two kinds of melatonin receptors, mtl and MT2 exist in the membrane and cytosol of brain cells, indicating that human fetal brain is a target organ of melatonin.

  14. Symphysis-fundal height curve in the diagnosis of fetal growth deviations

    Directory of Open Access Journals (Sweden)

    Djacyr Magna Cabral Freire

    2010-12-01

    Full Text Available OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%. In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve.

  15. Radiological evaluation of the fetal face using three-dimensional ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Bäumler M

    2012-12-01

    Full Text Available Marcel Bäumler,1–3 Michèle Bigorre,1,4 Jean-Michel Faure1,51CHU Montpellier, Centre de Compétence des Fentes Faciales, Hôpital Lapeyronie, Montpellier, 2Clinique du Parc, Imagerie de la Femme, Castelnau-le-Lez, 3Cabinet de Radiologie du Trident, Lunel, 4CHU Service de Chirurgie Plastique Pédiatrique, Hôpital Lapeyronie, Montpellier, 5CHU Montpellier, Service de Gynécologie-Obstétrique, Hôpital Arnaud de Villeneuve, Montpellier, FranceAbstract: This paper reviews screening and three-dimensional diagnostic ultrasound imaging of the fetal face. The different techniques available for analyzing biometric and morphological items of the profile, eyes, ears, lips, and hard and soft palate are commented on and briefly compared with the respective bi-dimensional techniques. The available literature supports the use of three-dimensional ultrasound in difficult prenatal diagnostic conditions because of its diagnostic accuracy, enabling improved safety of perinatal care. Globally, a marked increase has been observed in the accuracy of three-dimensional ultrasound in comparison with the bi-dimensional approach. Because there is no consensus about the performance of the different three-dimensional techniques, future studies are needed in order to compare them and to find the best technique for analysis of each of the respective facial elements. Universal prenatal standards may integrate these potential new findings in the future. At this time, the existing guidelines for prenatal facial screening should not be changed.Keywords: prenatal three-dimensional ultrasound, prenatal screening, prenatal diagnosis, cleft lip and palate, fetal profile, retrognathism

  16. Fetal Treatment 2017: The Evolution of Fetal Therapy Centers - A Joint Opinion from the International Fetal Medicine and Surgical Society (IFMSS) and the North American Fetal Therapy Network (NAFTNet).

    Science.gov (United States)

    Moon-Grady, Anita J; Baschat, Ahmet; Cass, Darrell; Choolani, Mahesh; Copel, Joshua A; Crombleholme, Timothy M; Deprest, Jan; Emery, Stephen P; Evans, Mark I; Luks, Francois I; Norton, Mary E; Ryan, Greg; Tsao, Kuojen; Welch, Ross; Harrison, Michael

    2017-01-01

    More than 3 decades ago, a small group of physicians and other practitioners active in what they called "fetal treatment" authored an opinion piece outlining the current status and future challenges anticipated in the field. Many advances in maternal, neonatal, and perinatal care and diagnostic and therapeutic modalities have been made in the intervening years, yet a thoughtful reassessment of the basic tenets put forth in 1982 has not been published. The present effort will aim to provide a framework for contemporary redefinition of the field of fetal treatment, with a brief discussion of the necessary minimum expertise and systems base for the provision of different types of interventions for both the mother and fetus. Our goal will be to present an opinion that encourages the advancement of thoughtful practice, ensuring that current and future patients have realistic access to centers with a range of fetal therapies with appropriate expertise, experience, and subspecialty and institutional support while remaining focused on excellence in care, collaborative scientific discovery, and maternal autonomy and safety. © 2017 S. Karger AG, Basel.

  17. Fetal Programming and Cardiovascular Pathology

    Science.gov (United States)

    Alexander, Barbara T.; Dasinger, John Henry; Intapad, Suttira

    2016-01-01

    Low birth weight serves as a crude proxy for impaired growth during fetal life and indicates a failure for the fetus to achieve its full growth potential. Low birth weight can occur in response to numerous etiologies that include complications during pregnancy, poor prenatal care, parental smoking, maternal alcohol consumption or stress. Numerous epidemiological and experimental studies demonstrate that birth weight is inversely associated with blood pressure and coronary heart disease. Sex and age impact the developmental programming of hypertension. In addition, impaired growth during fetal life also programs enhanced vulnerability to a secondary insult. Macrosomia, which occurs in response to maternal obesity, diabetes and excessive weight gain during gestation, is also associated with increased cardiovascular risk. Yet, the exact mechanisms that permanently change the structure, physiology and endocrine health of an individual across their lifespan following altered growth during fetal life are not entirely clear. Transmission of increased risk from one generation to the next in the absence of an additional prenatal insult indicates an important role for epigenetic processes. Experimental studies also indicate that the sympathetic nervous system, the renin angiotensin system, increased production of oxidative stress and increased endothelin play an important role in the developmental programming of blood pressure in later life. Thus, this review will highlight how adverse influences during fetal life and early development program an increased risk for cardiovascular disease including high blood pressure and provide an overview of the underlying mechanisms that contribute to the fetal origins of cardiovascular pathology. PMID:25880521

  18. Fetal programming and cardiovascular pathology.

    Science.gov (United States)

    Alexander, Barbara T; Dasinger, John Henry; Intapad, Suttira

    2015-04-01

    Low birth weight serves as a crude proxy for impaired growth during fetal life and indicates a failure for the fetus to achieve its full growth potential. Low birth weight can occur in response to numerous etiologies that include complications during pregnancy, poor prenatal care, parental smoking, maternal alcohol consumption, or stress. Numerous epidemiological and experimental studies demonstrate that birth weight is inversely associated with blood pressure and coronary heart disease. Sex and age impact the developmental programming of hypertension. In addition, impaired growth during fetal life also programs enhanced vulnerability to a secondary insult. Macrosomia, which occurs in response to maternal obesity, diabetes, and excessive weight gain during gestation, is also associated with increased cardiovascular risk. Yet, the exact mechanisms that permanently change the structure, physiology, and endocrine health of an individual across their lifespan following altered growth during fetal life are not entirely clear. Transmission of increased risk from one generation to the next in the absence of an additional prenatal insult indicates an important role for epigenetic processes. Experimental studies also indicate that the sympathetic nervous system, the renin angiotensin system, increased production of oxidative stress, and increased endothelin play an important role in the developmental programming of blood pressure in later life. Thus, this review will highlight how adverse influences during fetal life and early development program an increased risk for cardiovascular disease including high blood pressure and provide an overview of the underlying mechanisms that contribute to the fetal origins of cardiovascular pathology. © 2015 American Physiological Society.

  19. Prenatal diagnosis of fetal syndromes

    International Nuclear Information System (INIS)

    Murthy, BS Rama

    2008-01-01

    A syndrome is a pattern of multiple anomalies arising due to a single known causative factor. Ultrasonography has enabled us to recognize many fetal anomalies and dysmorphic features. Recognition of the anomaly pattern leads to the diagnosis of a particular syndrome. This enables us to counsel prospective parents and aids in management. We present a selection of fetal syndromes in the form of a pictorial essay

  20. Noninvasive fetal QRS detection using an echo state network and dynamic programming

    International Nuclear Information System (INIS)

    Lukoševičius, Mantas; Marozas, Vaidotas

    2014-01-01

    We address a classical fetal QRS detection problem from abdominal ECG recordings with a data-driven statistical machine learning approach. Our goal is to have a powerful, yet conceptually clean, solution. There are two novel key components at the heart of our approach: an echo state recurrent neural network that is trained to indicate fetal QRS complexes, and several increasingly sophisticated versions of statistics-based dynamic programming algorithms, which are derived from and rooted in probability theory. We also employ a standard technique for preprocessing and removing maternal ECG complexes from the signals, but do not take this as the main focus of this work. The proposed approach is quite generic and can be extended to other types of signals and annotations. Open-source code is provided. (paper)

  1. Fetal karyotype: can we always trust its result?

    Directory of Open Access Journals (Sweden)

    Carolina Leite Drummond

    2008-09-01

    Full Text Available We retrospectively investigated six cases of discrepancy between prenatal fetal karyotype and postnatal findings. In five cases, the chromosomal abnormalities initially found by CVS or amniocentesis were not confirmed by later analyses and postnatal examination. In one case, the fetal karyotype found to be normal by CVS had to be checked due to sonographic features and clinical anomalies found after birth. In most cases, the normal development on sonographic examination raised the doubt about the abnormal fetal karyotype. Discrepant findings between fetal karyotype results and sonographic findings require great caution in their interpretation and counseling of parents. Placental confined mosaicism seems to be the most frequent cause of such discrepant results. The interpretation of fetal karyotype results should always be correlated with sonographic and clinical findings.

  2. New treatment of early fetal chylothorax

    DEFF Research Database (Denmark)

    Nygaard, Ulrikka; Sundberg, Karin; Nielsen, Henriette Svarre

    2007-01-01

    OBJECTIVE: To evaluate OK-432, a preparation of Streptococcus pyogenes, in the treatment of early fetal chylothorax. METHODS: A prospective study of all fetuses (n=7) with persistent early chylothorax (gestational ages 16-21 weeks) referred to the tertiary center of fetal medicine in Denmark in 2...

  3. PREVENTION FETAL ALCOHOL SYNDROME IN RUSSIA

    Directory of Open Access Journals (Sweden)

    L. V. Skitnevskaya

    2013-01-01

    Full Text Available The article is devoted to the influence of alcohol problems in women of childbearing age during pregnancy on the unborn child. The concept of a fetal alcohol syndrome (FAS. We describe the stages of the research project "Prevention of fetal FAS in Russia."

  4. Glucocorticoid programming of the fetal male hippocampal epigenome.

    Science.gov (United States)

    Crudo, Ariann; Suderman, Matthew; Moisiadis, Vasilis G; Petropoulos, Sophie; Kostaki, Alisa; Hallett, Michael; Szyf, Moshe; Matthews, Stephen G

    2013-03-01

    The late-gestation surge in fetal plasma cortisol is critical for maturation of fetal organ systems. As a result, synthetic glucocorticoids (sGCs) are administered to pregnant women at risk of delivering preterm. However, animal studies have shown that fetal exposure to sGC results in increased risk of behavioral, endocrine, and metabolic abnormalities in offspring. Here, we test the hypothesis that prenatal GC exposure resulting from the fetal cortisol surge or after sGC exposure results in promoter-specific epigenetic changes in the hippocampus. Fetal guinea pig hippocampi were collected before (gestational day [GD52]) and after (GD65) the fetal plasma cortisol surge (Term∼GD67) and 24 hours after (GD52) and 14 days after (GD65) two repeat courses of maternal sGC (betamethasone) treatment (n = 3-4/gp). We identified extensive genome-wide alterations in promoter methylation in late fetal development (coincident with the fetal cortisol surge), whereby the majority of the affected promoters exhibited hypomethylation. Fetuses exposed to sGC in late gestation exhibited substantial differences in DNA methylation and histone h3 lysine 9 (H3K9) acetylation in specific gene promoters; 24 hours after the sGC treatment, the majority of genes affected were hypomethylated or hyperacetylated. However, 14 days after sGC exposure these differences did not persist, whereas other promoters became hypermethylated or hyperacetylated. These data support the hypothesis that the fetal GC surge is responsible, in part, for significant variations in genome-wide promoter methylation and that prenatal sGC treatment profoundly changes the epigenetic landscape, affecting both DNA methylation and H3K9 acetylation. This is important given the widespread use of sGC in the management of women in preterm labor.

  5. Piracetam for fetal distress in labour.

    Science.gov (United States)

    Hofmeyr, G Justus; Kulier, Regina

    2012-06-13

    Piracetam is thought to promote the metabolism of brain cells when they are hypoxic. It has been used to prevent adverse effects of fetal distress. The objective of this review was to assess the effects of piracetam for suspected fetal distress in labour on method of delivery and perinatal morbidity. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (15 February 2012). Randomised trials of piracetam compared with placebo or no treatment for suspected fetal distress in labour. Both review authors assessed eligibility and trial quality. One study of 96 women was included. Piracetam compared with placebo was associated with a trend to reduced need for caesarean section (risk ratio 0.57, 95% confidence interval 0.32 to 1.03). There were no statistically significant differences between the piracetam and placebo group for neonatal morbidity (measured by neonatal respiratory distress) or Apgar score. There is not enough evidence to evaluate the use of piracetam for fetal distress in labour.

  6. National natality and fetal mortality surveys

    International Nuclear Information System (INIS)

    Roney, P.L.

    1980-01-01

    A project is described in which the Epidemiologic Studies Branch, DBE, is cooperating with the National Center for Health Statistics in a National Natality Survey and a National Fetal Mortality Survey of a sample of live births and of late fetal deaths (28 or more weeks gestation) in 1979. Questionnaires will be sent to a sample of mothers who had a live born infant or late fetal death in 1979, to hospitals in which the deliveries took place, to attending physicians, and all other possible sources of health care. The survey will provide quantitative information regarding use of ionizing and nonionizing radiation, including ultrasound, during pregnancy and possible associations between radiation and late fetal mortality. Specifically the study will provide information on the demographic and socioeconomic characteristics of the mothers and complications of pregnancy, labor, and delivery. The physical condition of the infant at birth is also included. This is one of many health surveys conducted routinely by the NCHS under the National Health Survey program

  7. Evaluation of fetal anomalies with MR imaging

    International Nuclear Information System (INIS)

    Benson, R.C.; Platt, L.D.; Colletti, P.M.; Raval, J.K.; Boswell, W.D. Jr.; Halls, J.M.

    1987-01-01

    Twenty pregnant women underwent MR imaging (0.5 T) after US disclosed a significant fetal anomaly. The ability of MR imaging to depict the abnormalities was assessed. Of 20 abnormalities, 17 were visualized with MR imaging. Abnormalities included conjoined twins, omphalocele, gastroschisis, hydrocephalus, hydronephrosis, fetal ascites, facial teratoma, anencephaly, bladder outlet obstruction, thanatophoric dwarfism, cystic, hygroma, and fetal ovarian cyst. Thirteen of 14 abnormalities in third-trimester fetuses were visualized, as were four of six abnormalities in second-trimester fetuses. Associated polyhydramnios or oligohydramnios was evident in six of six cases. Anomalies were best delineated with T1-weighted sequences. The study suggests that MR imaging is potentially useful as a complementary imaging modality in the evaluation of fetal anomalies

  8. Impact of chronic maternal stress during early gestation on maternal-fetal stress transfer and fetal stress sensitivity in sheep.

    Science.gov (United States)

    Dreiling, Michelle; Schiffner, Rene; Bischoff, Sabine; Rupprecht, Sven; Kroegel, Nasim; Schubert, Harald; Witte, Otto W; Schwab, Matthias; Rakers, Florian

    2018-01-01

    Acute stress-induced reduction of uterine blood flow (UBF) is an indirect mechanism of maternal-fetal stress transfer during late gestation. Effects of chronic psychosocial maternal stress (CMS) during early gestation, as may be experienced by many working women, on this stress signaling mechanism are unclear. We hypothesized that CMS in sheep during early gestation augments later acute stress-induced decreases of UBF, and aggravates the fetal hormonal, cardiovascular, and metabolic stress responses during later development. Six pregnant ewes underwent repeated isolation stress (CMS) between 30 and 100 days of gestation (dGA, term: 150 dGA) and seven pregnant ewes served as controls. At 110 dGA, ewes were chronically instrumented and underwent acute isolation stress. The acute stress decreased UBF by 19% in both the CMS and control groups (p stress-induced cortisol and norepinephrine concentrations indicating a hyperactive hypothalamus-pituitary-adrenal (HPA)-axis and sympathetic-adrenal-medullary system. Increased fetal norepinephrine is endogenous as maternal catecholamines do not cross the placenta. Cortisol in the control but not in the CMS fetuses was correlated with maternal cortisol blood concentrations; these findings indicate: (1) no increased maternal-fetal cortisol transfer with CMS, (2) cortisol production in CMS fetuses when the HPA-axis is normally inactive, due to early maturation of the fetal HPA-axis. CMS fetuses were better oxygenated, without shift towards acidosis compared to the controls, potentially reflecting adaptation to repeated stress. Hence, CMS enhances maternal-fetal stress transfer by prolonged reduction in UBF and increased fetal HPA responsiveness.

  9. Intermittent auscultation of fetal heart rate during labour - a widely accepted technique for low risk pregnancies: but are the current national guidelines robust and practical?

    Science.gov (United States)

    Sholapurkar, S L

    2010-01-01

    Intermittent auscultation of fetal heart rate is an accepted practice in low risk labours in many countries. National guidelines on intrapartum fetal monitoring were critically reviewed regarding timing and frequency of intermittent auscultation. Hypothetical but plausible examples are presented to illustrate that it may be possible to miss significant fetal distress with strict adherence to current guidelines. Opinion is forwarded that intermittent auscultation should be performed for 60 seconds before and after three contractions over about 10 min every half an hour in the first stage of labour. Reasons are put forward to show how this could be more practical and patient friendly and at the same time could improve detection of fetal distress. The current recommendation of intermittent auscultation every 15 min in the first stage is associated with poor compliance and leads to unnecessary burden, stress and medicolegal liability for birth attendants. Modification of current national guidelines would be desirable.

  10. Fetal source extraction from magnetocardiographic recordings by dependent component analysis

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Draulio B de [Department of Physics and Mathematics, FFCLRP, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Barros, Allan Kardec [Department of Electrical Engineering, Federal University of Maranhao, Sao Luis, Maranhao (Brazil); Estombelo-Montesco, Carlos [Department of Physics and Mathematics, FFCLRP, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Zhao, Hui [Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Filho, A C Roque da Silva [Department of Physics and Mathematics, FFCLRP, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Baffa, Oswaldo [Department of Physics and Mathematics, FFCLRP, University of Sao Paulo, Ribeirao Preto, SP (Brazil); Wakai, Ronald [Department of Medical Physics, University of Wisconsin, Madison, WI (United States); Ohnishi, Noboru [Department of Information Engineering, Nagoya University (Japan)

    2005-10-07

    Fetal magnetocardiography (fMCG) has been extensively reported in the literature as a non-invasive, prenatal technique that can be used to monitor various functions of the fetal heart. However, fMCG signals often have low signal-to-noise ratio (SNR) and are contaminated by strong interference from the mother's magnetocardiogram signal. A promising, efficient tool for extracting signals, even under low SNR conditions, is blind source separation (BSS), or independent component analysis (ICA). Herein we propose an algorithm based on a variation of ICA, where the signal of interest is extracted using a time delay obtained from an autocorrelation analysis. We model the system using autoregression, and identify the signal component of interest from the poles of the autocorrelation function. We show that the method is effective in removing the maternal signal, and is computationally efficient. We also compare our results to more established ICA methods, such as FastICA.

  11. Adipokines and their relation to maternal energy substrate production, insulin resistance and fetal size.

    Science.gov (United States)

    Ahlsson, Fredrik; Diderholm, Barbro; Ewald, Uwe; Jonsson, Björn; Forslund, Anders; Stridsberg, Mats; Gustafsson, Jan

    2013-05-01

    The role of adipokines in the regulation of energy substrate production in non-diabetic pregnant women has not been elucidated. We hypothesize that serum concentrations of adiponectin are related to fetal growth via maternal fat mass, insulin resistance and glucose production, and further, that serum levels of leptin are associated with lipolysis and that this also influences fetal growth. Hence, we investigated the relationship between adipokines, energy substrate production, insulin resistance, body composition and fetal weight in non-diabetic pregnant women in late gestation. Twenty pregnant women with normal glucose tolerance were investigated at 36 weeks of gestation at Uppsala University Hospital. Levels of adipokines were related to rates of glucose production and lipolysis, maternal body composition, insulin resistance, resting energy expenditure and estimated fetal weights. Rates of glucose production and lipolysis were estimated by stable isotope dilution technique. Median (range) rate of glucose production was 805 (653-1337) μmol/min and that of glycerol production, reflecting lipolysis, was 214 (110-576) μmol/min. HOMA insulin resistance averaged 1.5 ± 0.75 and estimated fetal weights ranged between 2670 and 4175 g (-0.2 to 2.7 SDS). Mean concentration of adiponectin was 7.2 ± 2.5mg/L and median level of leptin was 47.1 (9.9-58.0) μg/L. Adiponectin concentrations (7.2 ± 2.5mg/L) correlated inversely with maternal fat mass, insulin resistance, glucose production and fetal weight, r=-0.50, pinsulin resistance, r=0.76, pinsulin resistance as well as endogenous glucose production rates indicate that low levels of adiponectin in obese pregnant women may represent one mechanism behind increased fetal size. Maternal levels of leptin are linked to maternal fat mass and its metabolic consequences, but the data indicate that leptin lacks a regulatory role with regard to maternal lipolysis in late pregnancy. Copyright © 2012 Elsevier Ireland Ltd. All rights

  12. ACR Appropriateness Criteria Assessment of Fetal Well-Being.

    Science.gov (United States)

    Simpson, Lynn; Khati, Nadia J; Deshmukh, Sandeep P; Dudiak, Kika M; Harisinghani, Mukesh G; Henrichsen, Tara L; Meyer, Benjamin J; Nyberg, David A; Poder, Liina; Shipp, Thomas D; Zelop, Carolyn M; Glanc, Phyllis

    2016-12-01

    Although there is limited evidence that antepartum testing decreases the risk for fetal death in low-risk pregnancies, women with high-risk factors for stillbirth should undergo antenatal fetal surveillance. The strongest evidence supporting antepartum testing pertains to pregnancies complicated by intrauterine fetal growth restriction secondary to uteroplacental insufficiency. The main ultrasound-based modalities to determine fetal health are the biophysical profile, modified biophysical profile, and duplex Doppler velocimetry. In patients at risk for cardiovascular compromise, fetal echocardiography may also be indicated to ensure fetal well-being. Although no single antenatal test has been shown to be superior, all have high negative predictive values. Weekly or twice-weekly fetal testing has become the standard practice in high-risk pregnancies. The timing for the initiation of assessments of fetal well-being should be tailored on the basis of the risk for stillbirth and the likelihood of survival with intervention. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer-reviewed journals and the application of well-established methodologies (the RAND/UCLA Appropriateness Method and the Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Sex differences in the fetal programming of hypertension.

    Science.gov (United States)

    Grigore, Daniela; Ojeda, Norma B; Alexander, Barbara T

    2008-01-01

    Numerous clinical and experimental studies support the hypothesis that the intrauterine environment is an important determinant of cardiovascular disease and hypertension. This review examined the mechanisms linking an adverse fetal environment and increased risk for chronic disease in adulthood with an emphasis on gender differences and the role of sex hormones in mediating sexual dimorphism in response to a suboptimal fetal environment. This review focuses on current findings from the PubMed database regarding animal models of fetal programming of hypertension, sex differences in phenotypic outcomes, and potential mechanisms in offspring of mothers exposed to an adverse insult during gestation. For the years 1988 to 2007, the database was searched using the following terms: fetal programming, intrauterine growth restriction, low birth weight, sex differences, estradiol, testosterone, high blood pressure, and hypertension. The mechanisms involved in the fetal programming of adult disease are multifactorial and include alterations in the regulatory systems affecting the long-tterm control of arterial pressure. Sex differences have been observed in animal models of fetal programming, and recent studies suggest that sex hormones may modulate activity of regulatory systems, leading to a lower incidence of hypertension and vascular dysfunction in females compared with males. Animal models of fetal programming provide critical support for the inverse relationship between birth weight and blood pressure. Experimental models demonstrate that sex differences are observed in the pathophysiologic response to an adverse fetal environment. A role for sex hormone involvement is strongly suggested,with modulation of the renin-angiotensin system as a possible mechanism.

  14. Fetal DNA: strategies for optimal recovery

    NARCIS (Netherlands)

    Legler, Tobias J.; Heermann, Klaus-Hinrich; Liu, Zhong; Soussan, Aicha Ait; van der Schoot, C. Ellen

    2008-01-01

    For fetal DNA extraction, in principle each DNA extraction method can be used; however, because most methods have been optimized for genomic DNA from leucocytes, we describe here the methods that have been optimized for the extraction of fetal DNA from maternal plasma and validated for this purpose

  15. Routine screening for fetal anomalies: expectations.

    Science.gov (United States)

    Goldberg, James D

    2004-03-01

    Ultrasound has become a routine part of prenatal care. Despite this, the sensitivity and specificity of the procedure is unclear to many patients and healthcare providers. In a small study from Canada, 54.9% of women reported that they had received no information about ultrasound before their examination. In addition, 37.2% of women indicated that they were unaware of any fetal problems that ultrasound could not detect. Most centers that perform ultrasound do not have their own statistics regarding sensitivity and specificity; it is necessary to rely on large collaborative studies. Unfortunately, wide variations exist in these studies with detection rates for fetal anomalies between 13.3% and 82.4%. The Eurofetus study is the largest prospective study performed to date and because of the time and expense involved in this type of study, a similar study is not likely to be repeated. The overall fetal detection rate for anomalous fetuses was 64.1%. It is important to note that in this study, ultrasounds were performed in tertiary centers with significant experience in detecting fetal malformations. The RADIUS study also demonstrated a significantly improved detection rate of anomalies before 24 weeks in tertiary versus community centers (35% versus 13%). Two concepts seem to emerge from reviewing these data. First, patients must be made aware of the limitations of ultrasound in detecting fetal anomalies. This information is critical to allow them to make informed decisions whether to undergo ultrasound examination and to prepare them for potential outcomes.Second, to achieve the detection rates reported in the Eurofetus study, ultrasound examination must be performed in centers that have extensive experience in the detection of fetal anomalies.

  16. Sonographic fetal weight estimation using femoral length: Honarvar Equation

    International Nuclear Information System (INIS)

    Firoozabadi, Raziah Dehghani; Ghasemi, N.; Firoozabadi, Mehdi Dehghani

    2007-01-01

    Fetal growth is the result of interactions between various factors and can be estimated by ultrasonic measurements. Fetal femur length is a scale for estimating the fetal weight in individual races because fetal growth patterns differ among different races. This was a prospective study involving 500 pregnant women at 36 weeks of gestational age. Real-time sonography was done to measure the femoral length and the weight of the fetus was estimated by the Honarvar 2 equation. The correlation between estimated fetal weight (EFW) and real weight was tested by Pearson correlation coefficient and relationships with the age and BMI of mother, the sex of the neonate and parity were tested by multiple regression. EFW by the Honarvar 2 equation correlated significantly with actual birthweight. Therefore, this equation is valid for fetal weight estimation. It also does not depend on the age and BMI of the mother, sex of the neonate, parity. Ethnicity potentially plays an important role in the fetal weight estimation. The Honarvar formula produced the best estimate of the actual birthweight for Iranian fetuses, and its use is recommended. (author)

  17. Maternal methadone dosing schedule and fetal neurobehavior

    Science.gov (United States)

    Jansson, Lauren M.; DiPietro, Janet A.; Velez, Martha; Elko, Andrea; Knauer, Heather; Kivlighan, Katie T.

    2008-01-01

    Objective Daily methadone maintenance is the standard of care for opiate dependency during pregnancy. Previous research has indicated that single-dose maternal methadone administration significantly suppresses fetal neurobehaviors. The purpose of this study was to determine if split-dosing would have less impact on fetal neurobehavior than single-dose administration. Methods Forty methadone-maintained women were evaluated at peak and trough maternal methadone levels on single- and split-dosing schedules. Monitoring sessions occurred at 36 and 37 weeks gestation in a counterbalanced study design. Fetal measures included heart rate, variability, accelerations, motor activity and fetal movement-heart rate coupling (FM-FHR). Maternal measures included heart period, variability, skin conductance, respiration and vagal tone. Repeated measure analysis of variance was used to evaluate within-subject changes between split- and single-dosing regimens. Results All fetal neurobehavioral parameters were suppressed by maternal methadone administration, regardless of dosing regimen. Fetal parameters at peak were significantly lower during single vs. split methadone administration. FM-FHR coupling was less suppressed from trough to peak during split-dosing vs. single-dosing. Maternal physiologic parameters were generally unaffected by dosing condition. Conclusion Split- dosed fetuses displayed less neurobehavioral suppression from trough to peak maternal methadone levels as compared to single-dosed fetuses. Split-dosing may be beneficial for methadone-maintained pregnant women. PMID:19085624

  18. Fetal pain

    NARCIS (Netherlands)

    Adama van Scheltema, Phebe

    2011-01-01

    Recent studies have suggested that the fetus is capable of exhibiting a stress response to intrauterine needling, resulting in alterations in fetal stress hormone levels. Intrauterine transfusions are performed by inserting a needle either in the umbilical cord root at the placental surface (PCI),

  19. Invasive Fetal Therapy: Global Status and Local Development

    Directory of Open Access Journals (Sweden)

    Ming Chen

    2004-12-01

    Full Text Available There are few congenital anomalies that can be treated in utero, despite the rapid development of fetal medicine. The number of available antenatal treatments is growing with the advance of supplementary tools, especially ultrasound and endoscopy. Disorders involving accumulation of excessive fluid in the amniotic cavity (polyhydramnios, chest (hydrothorax, abdomen (ascites and urinary system (obstructive uropathy are regularly treated using aspiration or shunt drainage under ultrasound monitoring. Electrolyte solutions or concentrated blood component supplements are used to treat oligohydramnios (amnioinfusion and amniopatch and fetal anemia (fetal transfusion. Placental tumor (chorioangioma and fetal tumors (cystic hygroma and sacrococcygeal teratoma are also successfully treated by antenatal injection of medications. Fetoscopic procedures, especially obstetric endoscopy, are now used regularly in North America, Europe, Australasia and Japan after the validity was established in the treatment of twin-twin transfusion syndrome when compared with traditional amnioreduction. However, most procedures involving surgical fetoscopy or open fetal surgery remain experimental. Their validity and efficacy are not confirmed in a number of fetal diseases for which they were claimed to be effective. A brief review of the global status and history of invasive fetal therapy is given, and its status in Taiwan is also described. Future development in this field relies on greater understanding of the basic physiology and pathology of the diseases involved, as well as on the progress of sophisticated instrumentation.

  20. Non-nutritive sucking recorded in utero via fetal magnetography

    International Nuclear Information System (INIS)

    Popescu, E A; Popescu, M; Gustafson, K M; Wang, J; Barlow, S M

    2008-01-01

    Several studies in term and pre-term infants have investigated the rhythmic pattern of non-nutritive sucking (NNS) indicating correlations between the quantitative measures derived from sucking pressure variation and/or electromyographic (EMG) recordings and a range of factors that include age, perinatal stress and sequelae. In the human fetus, NNS has been reported from 13 weeks of gestation and has been studied using real-time Doppler ultrasonography exclusively. The present study indicates that NNS in fetus can be reliably recorded and quantified using non-invasive biomagnetic measurements that have been recently introduced as an investigational tool for the assessment of fetal neurophysiologic development. We show that source separation techniques, such as independent component analysis, applied to the high-resolution multichannel recordings allow the segregation of an explicit waveform that represents the biomagnetic equivalent of the ororhythmic sucking pressure variation or EMG signal recorded in infants. This enables the morphological study of NNS patterning over different temporal scales, from the global quantitative measures to the within burst fine structure characterization, in correlation with the fetal cardiac rhythm

  1. Fetal bowel anomalies - US and MR assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rubesova, Erika [Stanford University, Department of Radiology, Lucile Packard Children' s Hospital, Stanford, CA (United States)

    2012-01-15

    The technical quality of prenatal US and fetal MRI has significantly improved during the last decade and allows an accurate diagnosis of bowel pathology prenatally. Accurate diagnosis of bowel pathology in utero is important for parental counseling and postnatal management. It is essential to recognize the US presentation of bowel pathology in the fetus in order to refer the patient for further evaluation or follow-up. Fetal MRI has been shown to offer some advantages over US for specific bowel abnormalities. In this paper, we review the normal appearance of the fetal bowel on US and MRI as well as the typical presentations of bowel pathologies. We discuss more specifically the importance of recognizing on fetal MRI the abnormalities of size and T1-weighted signal of the meconium-filled distal bowel. (orig.)

  2. The relationship between fetal biophysical profile and cord blood PH

    Directory of Open Access Journals (Sweden)

    Valadan M

    2009-02-01

    Full Text Available "nBackground: The Biophysical Profile (BPP is a noninvasive test that predicts the presence or absence of fetal asphyxia and, ultimately, the risk of fetal death in the antenatal period. Intervention on the basis of an abnormal biophysical profile result has been reported to yield a significant reduction in prenatal mortality, and an association exists between biophysical profile scoring and a decreased cerebral palsy rate in a given population. The BPP evaluates five characteristics: fetal movement, tone, breathing, heart reactivity, and amniotic fluid (AF volume estimation. The purpose of study was to determine whether there are different degree of acidosis at which the biophysical activity (acute marker are affected. "nMethods: In a prospective study of 140 patients undergoing cesarean section before onset of labor, the fetal biophysical profile was performed 24h before the time of cesarean and was matched with cord arterial PH that was obtained from a cord segment (10-20cm that was double clamped after delivery of newborn. (using cord arterial PH less than 7.20 for the diagnosis of acidosis. "nResults: The fetal biophysical profile was found to have a significant relationship with umbilical blood PH. The sensitivity, specificity, positive predictive value, negative predictive value of fetal biophysical profile score were: 88.9%, 88.6%, 50%, 98.1%. "nConclusion: The first manifestations of fetal acidosis are nonreactive nonstress testing and fetal breathing loss; in advanced acidemia fetal movements and fetal tone are compromised. A protocol of antepartum fetal evaluation is suggested based upon the individual biophysical components rather than the score alone.

  3. Fetal Intracranial Hemorrhage (Fetal Stroke: Report of Four Antenatally Diagnosed Casesand Review of the Literature

    Directory of Open Access Journals (Sweden)

    Ying-Fen Huang

    2006-06-01

    Conclusion: This small series demonstrate that an antenatal diagnosis of fetal stroke with intraventricular hemorrhage Grades III and IV or with brain parenchymal involvement appears to be associated with poor neurologic outcome. Due to the significant neonatal neurologic impairment and potential medicolegal implications of antepartum fetal ICH, it follows that obstetricians and sonographers should be familiar with predisposing factors and typical diagnostic imaging findings of rare in utero ICH events.

  4. Fetal Intelligent Navigation Echocardiography (FINE): a novel method for rapid, simple, and automatic examination of the fetal heart.

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto

    2013-09-01

    To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate the anatomy surrounding each of the nine cardiac diagnostic planes (Virtual Intelligent Sonographer Assistance (VIS-Assistance®)). The method consists of marking seven anatomical structures of the fetal heart. The following echocardiography views are then automatically generated: 1) four chamber; 2) five chamber; 3) left ventricular outflow tract; 4) short-axis view of great vessels/right ventricular outflow tract; 5) three vessels and trachea; 6) abdomen/stomach; 7) ductal arch; 8) aortic arch; and 9) superior and inferior vena cava. The FINE method was tested in a separate set of 50 STIC volumes of normal hearts (18.6-37.2 weeks of gestation), and visualization rates for fetal echocardiography views using diagnostic planes and/or VIS-Assistance® were calculated. To examine the feasibility of identifying abnormal cardiac anatomy, we tested the method in four cases with proven congenital heart defects (coarctation of aorta, tetralogy of Fallot, transposition of great vessels and pulmonary atresia with intact ventricular septum). In normal cases, the FINE method was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 78-100% of cases; 2) VIS-Assistance® in 98-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance® in 98-100% of cases. In all four abnormal cases, the FINE method demonstrated evidence of abnormal fetal cardiac anatomy. The FINE method can be used to visualize nine standard fetal echocardiography views in normal hearts by applying 'intelligent navigation' technology to STIC volume datasets. This method can simplify

  5. Does the Use of Diagnostic Technology Reduce Fetal Mortality?

    Science.gov (United States)

    Grytten, Jostein; Skau, Irene; Sørensen, Rune; Eskild, Anne

    2018-01-19

    To examine the effect that the introduction of new diagnostic technology in obstetric care has had on fetal death. The Medical Birth Registry of Norway provided detailed medical information for approximately 1.2 million deliveries from 1967 to 1995. Information about diagnostic technology was collected directly from the maternity units, using a questionnaire. The data were analyzed using a hospital fixed-effects regression with fetal mortality as the outcome measure. The key independent variables were the introduction of ultrasound and electronic fetal monitoring at each maternity ward. Hospital-specific trends and risk factors of the mother were included as control variables. The richness of the data allowed us to perform several robustness tests. The introduction of ultrasound caused a significant drop in fetal mortality rate, while the introduction of electronic fetal monitoring had no effect on the rate. In the population as a whole, ultrasound contributed to a reduction in fetal deaths of nearly 20 percent. For post-term deliveries, the reduction was well over 50 percent. The introduction of ultrasound made a major contribution to the decline in fetal mortality at the end of the last century. © Health Research and Educational Trust.

  6. Fibromodulin Is Essential for Fetal-Type Scarless Cutaneous Wound Healing.

    Science.gov (United States)

    Zheng, Zhong; Zhang, Xinli; Dang, Catherine; Beanes, Steven; Chang, Grace X; Chen, Yao; Li, Chen-Shuang; Lee, Kevin S; Ting, Kang; Soo, Chia

    2016-11-01

    In contrast to adult and late-gestation fetal skin wounds, which heal with scar, early-gestation fetal skin wounds display a remarkable capacity to heal scarlessly. Although the underlying mechanism of this transition from fetal-type scarless healing to adult-type healing with scar has been actively investigated for decades, in utero restoration of scarless healing in late-gestation fetal wounds has not been reported. In this study, using loss- and gain-of-function rodent fetal wound models, we identified that fibromodulin (Fm) is essential for fetal-type scarless wound healing. In particular, we found that loss of Fm can eliminate the ability of early-gestation fetal rodents to heal without scar. Meanwhile, administration of fibromodulin protein (FM) alone was capable of restoring scarless healing in late-gestation rat fetal wounds, which naturally heal with scar, as characterized by dermal appendage restoration and organized collagen architectures that were virtually indistinguishable from those in age-matched unwounded skin. High Fm levels correlated with decreased transforming growth factor (TGF)-β1 expression and scarless repair, while low Fm levels correlated with increased TGF-β1 expression and scar formation. This study represents the first successful in utero attempt to induce scarless repair in late-gestation fetal wounds by using a single protein, Fm, and highlights the crucial role that the FM-TGF-β1 nexus plays in fetal-type scarless skin repair. Copyright © 2016 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  7. Inter-observer variability in fetal biometric measurements.

    Science.gov (United States)

    Kilani, Rami; Aleyadeh, Wesam; Atieleh, Luay Abu; Al Suleimat, Abdul Mane; Khadra, Maysa; Hawamdeh, Hassan M

    2018-02-01

    To evaluate inter-observer variability and reproducibility of ultrasound measurements for fetal biometric parameters. A prospective cohort study was implemented in two tertiary care hospitals in Amman, Jordan; Prince Hamza Hospital and Albashir Hospital. 192 women with a singleton pregnancy at a gestational age of 18-36 weeks were the participants in the study. Transabdominal scans for fetal biometric parameter measurement were performed on study participants from the period of November 2014 to March 2015. Women who agreed to participate in the study were administered two ultrasound scans for head circumference, abdominal circumference and femur length. The correlation coefficient was calculated. Bland-Altman plots were used to analyze the degree of measurement agreement between observers. Limits of agreement ± 2 SD for the differences in fetal biometry measurements in proportions of the mean of the measurements were derived. Main outcome measures examine the reproducibility of fetal biometric measurements by different observers. High inter-observer inter-class correlation coefficient (ICC) was found for femur length (0.990) and abdominal circumference (0.996) where Bland-Altman plots showed high degrees of agreement. The highest degrees of agreement were noted in the measurement of abdominal circumference followed by head circumference. The lowest degree of agreement was found for femur length measurement. We used a paired-sample t-test and found that the mean difference between duplicate measurements was not significant (P > 0.05). Biometric fetal parameter measurements may be reproducible by different operators in the clinical setting with similar results. Fetal head circumference, abdominal circumference and femur length were highly reproducible. Large organized studies are needed to ensure accurate fetal measurements due to the important clinical implications of inaccurate measurements. Copyright © 2018. Published by Elsevier B.V.

  8. Anti-inflammatory Elafin in human fetal membranes.

    Science.gov (United States)

    Stalberg, Cecilia; Noda, Nathalia; Polettini, Jossimara; Jacobsson, Bo; Menon, Ramkumar

    2017-02-01

    Elafin is a low molecular weight protein with antileukoproteinase, anti-inflammatory, antibacterial and immunomodulating properties. The profile of Elafin in fetal membranes is not well characterized. This study determined the changes in Elafin expression and concentration in human fetal membrane from patients with preterm prelabor rupture of membranes (PPROM) and in vitro in response to intra-amniotic polymicrobial pathogens. Elafin messenger RNA (mRNA) expressions were studied in fetal membranes from PPROM, normal term as well as in normal term not in labor membranes in an organ explant system treated (24 h) with lipopolysaccharide (LPS), using quantitative reverse transcription-polymerase chain reaction (RT-PCR). Enzyme-linked immunosorbent assay (ELISA) measured Elafin concentrations in culture supernatants from tissues treated with LPS and polybacterial combinations of heat-inactivated Mycoplasma hominis (MH), Ureaplasma urealyticum (UU) and Gardnerella vaginalis (GV). Elafin mRNA expression in fetal membranes from women with PPROM was significantly higher compared to women who delivered at term after normal pregnancy (5.09±3.50 vs. 11.71±2.21; Pmembranes showed a significantly increased Elafin m-RNA expression (Pmembranes also showed no changes in Elafin protein concentrations compared to untreated controls. Higher Elafin expression in PPROM fetal membranes suggests a host response to an inflammatory pathology. However, lack of Elafin response to LPS and polymicrobial treatment is indicative of the minimal anti-inflammatory impact of this molecule in fetal membranes.

  9. Ultrasonographic Findings of Fetal Congenital Intracranial Teratoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong [Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Young Ho; Song, Mi Jin; Cho, Jeong Yeon; Min, Jee Yeon; Moon, Min Hwan; Kim, Jeong Ah [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2005-06-15

    To evaluate the sonographic findings of fetal congenital intracranial teratoma. From 1994 to 2002, of the 11 fetuses which had been diagnosed with fetal intracranial tumors after second level fetal ultrasonography, the six that were confirmed after autopsy as congenital intracranial teratomas were included in our study. The sonographic findings, including size, homogeneity, echogenicity compared with surrounding normal brain tissues, cystic components, and tumor related calcification, were retrospectively evaluated. The incidence of fetal congenital intracranial teratoma out of all fetal intracranial tumors was 54.5% (6 of 11 cases) during the 8-year period. The mean mass size was 7.4 cm (3.0-15.0 cm). Two thirds of (4/6) of the teratoma cases showed high echogenicity compared with normal brain tissues, and two thirds (4/6) showed heterogeneous echogenicity. Four teratoma cases (67%) showed cysts in the mass with a mean size of 1.9cm. One third (2/6) showed calcifications within the tumor. Out of the six cases, two had oropharyngeal teratoma with extension into the intracranial portion (so called epignathus) and showed homogenous mass without any cysts or calcifications. The typical sonographic appearance of intracranial teratoma was a heterogeneous, hyperechoic mass with cysts. In the epignathus cases, the sonographic appearances differed somewhat from the others. An understanding of the sonographic findings of fetal intracranial teratoma will help in the timely counseling of the parents and in obstetric decision making

  10. Agonist mediated fetal muscle-type nicotinic acetylcholine receptor desensitization

    Science.gov (United States)

    The exposure of a developing embryo or fetus to teratogenic alkaloids from plants has the potential to cause developmental defects in livestock due to the inhibition of fetal movement by alkaloids. The mechanism behind the inhibition of fetal movement is the desensitization of fetal muscle-type nico...

  11. The investigation of fetal doses in mantle field irradiation

    International Nuclear Information System (INIS)

    Karacam, S. C; Gueralp, O. S; Oeksuez, D. C; Koca, A.; Cepni, I.; Cepni, K.; Bese, N.

    2009-01-01

    To determine clinically the fetal dose from irradiation of Hodgkin's disease during pregnancy and to quantify the components of fetal dose using phantom measurements. The fetal dose was measured with phantom measurements using thermoluminescent dosemeters (TLDs). Phantom measurements were performed by simulating the treatment conditions on an anthropomorphic phantom. TLDs were placed on the phantom 41, 44, 46.5 and 49.5 cm from the centre of the treatment field. Two TLDs were placed on the surface of the phantom. The estimated total dose to all the TLDs ranged from 8.8 to 13.2 cGy for treatment with 60 Co and from 8.2 to 11.8 cGy for 4 MV photons. It was concluded that the doses in different sections were evaluated to investigate dose changes in different points and depths of fetal tissues in phantom. Precise planning and the use of supplemental fetal shielding may help reduce fetal exposure. (authors)

  12. Growth assessment in diagnosis of Fetal Growth Restriction. Review.

    Science.gov (United States)

    Albu, A R; Horhoianu, I A; Dumitrascu, M C; Horhoianu, V

    2014-06-15

    The assessment of fetal growth represents a fundamental step towards the identification of the true growth restricted fetus that is associated to important perinatal morbidity and mortality. The possible ways of detecting abnormal fetal growth are taken into consideration in this review and their strong and weak points are discussed. An important debate still remains about how to discriminate between the physiologically small fetus that does not require special surveillance and the truly growth restricted fetus who is predisposed to perinatal complications, even if its parameters are above the cut-off limits established. In this article, we present the clinical tools of fetal growth assessment: Symphyseal-Fundal Height (SFH) measurement, the fetal ultrasound parameters widely taken into consideration when discussing fetal growth: Abdominal Circumference (AC) and Estimated Fetal Weight (EFW); several types of growth charts and their characteristics: populational growth charts, standard growth charts, individualized growth charts, customized growth charts and growth trajectories.

  13. Investigation of fetal weight determination in x-ray pelvimetry

    International Nuclear Information System (INIS)

    Chung, M. C.; Tae, S.; Lee, H. K.; Kwon, K. H.; Chung, W. K.; Kim, K. J.

    1981-01-01

    The x-ray pelvimetry is widely used for investigation of fetal weight determination by measuring the size of the fetal head. The report concerns 173 cases with Colcher-Sussman method from January, 1, 1977 to December, 31, 1980 at Soonchunhyang College Hospital. We measured fetal head diameter in both A-P and lateral projections. The brief results are as follows: 1) Among the total 173 cases, vaginal delivery is 88 cases and Cesarean section is 85 cases. 2) The rate of Cesarean section is increased over 35 year of age and 4,000 gm of birth weight. 3) The rate of Cesarean section is increased in abnormal presentation. 4) The relationship between the fetal head diameter and the fetal weight is more significant in A-P puus lateral projection tha A-P only. 5) The average size of the fetal head is 0.8 cm larger in Cesarean section than in vaginal delivery

  14. Investigation of fetal weight determination in X-ray pelvimetry

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M. D.; Tae, S.; Lee, H. K.; Kwon, K. H.; Chung, W. K.; Kim, K. J. [Soon Chung Hyang College Hospital, Chunan (Korea, Republic of)

    1981-06-15

    The X-ray pelvimetry is widely used for investigation of fetal weight determination by measuring the size of the fetal head. The report concerns 173 cases with Colcher-Sussman method from January 1'77 to December 31'80 at Soon Chun Hyang college hospital. We measured fetal head diameter in both A-P and lateral projections. The brief results are as follows: 1)Among the total 173 cases, vaginal delivery is 88 cases and Cesarean section is 85 cases. 2) The rate of Cesarean section is increased over 35 years of age and 4,000 gm of birth weight. 3) The rate of Cesarean section is increased in abnormal presentation. 4) The relationship between the fetal head diameter and the fetal weight is more significant in A-P plus lateral projection than A-P only. 5) The average size of the fetal head is 0.8cm larger in Cesarean section than in vaginal delivery.

  15. Investigation of fetal weight determination in X-ray pelvimetry

    International Nuclear Information System (INIS)

    Chung, M. D.; Tae, S.; Lee, H. K.; Kwon, K. H.; Chung, W. K.; Kim, K. J.

    1981-01-01

    The X-ray pelvimetry is widely used for investigation of fetal weight determination by measuring the size of the fetal head. The report concerns 173 cases with Colcher-Sussman method from January 1'77 to December 31'80 at Soon Chun Hyang college hospital. We measured fetal head diameter in both A-P and lateral projections. The brief results are as follows: 1)Among the total 173 cases, vaginal delivery is 88 cases and Cesarean section is 85 cases. 2) The rate of Cesarean section is increased over 35 years of age and 4,000 gm of birth weight. 3) The rate of Cesarean section is increased in abnormal presentation. 4) The relationship between the fetal head diameter and the fetal weight is more significant in A-P plus lateral projection than A-P only. 5) The average size of the fetal head is 0.8cm larger in Cesarean section than in vaginal delivery

  16. Relationship between glutamate, GOT and GPT levels in maternal and fetal blood: a potential mechanism for fetal neuroprotection.

    Science.gov (United States)

    Zlotnik, Alexander; Tsesis, Svetlana; Gruenbaum, Benjamin Fredrick; Ohayon, Sharon; Gruenbaum, Shaun Evan; Boyko, Matthew; Sheiner, Eyal; Brotfain, Evgeny; Shapira, Yoram; Teichberg, Vivian Itzhak

    2012-09-01

    Excess glutamate in the brain is thought to be implicated in the pathophysiology of fetal anoxic brain injury, yet little is known about the mechanisms by which glutamate is regulated in the fetal brain. This study examines whether there are differences between maternal and fetal glutamate concentrations, and whether a correlation between them exists. 10 ml of venous blood was extracted from 87 full-term (>37 weeks gestation) pregnant women in active labor. Immediately after delivery of the neonate, 10 ml of blood from the umbilical artery and vein was extracted. Samples were analyzed for levels of glutamate, glutamate-oxaloacetate transaminase (GOT), and glutamate pyruvate transaminase (GPT). Fetal blood glutamate concentrations in both the umbilical artery and vein were found to be significantly higher than maternal blood (pGOT levels in the umbilical artery and vein were found to be significantly higher than maternal GOT levels (pGOT or GPT between the umbilical artery and vein. There was an association observed between glutamate levels in maternal blood and glutamate levels in both venous (R=0.32, pGOT, but not GPT levels. An association was observed between maternal and fetal blood glutamate levels. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Fetal abuse and neglect: an emerging controversy.

    Science.gov (United States)

    Landwirth, J

    1987-04-01

    Advances in fetal medicine have expanded opportunities for protection of fetal health and intrauterine management of an increasing number of fetal disorders. The legal rights and duties of parents to provide necessary medical treatment for the child may extend to the prenatal period. Resolution of the conflict between the rights of the fetus to be born healthy and the pregnant woman's right of privacy is difficult and controversial. It is suggested that intrusion into a woman's individual fundamental rights for the potential benefit of her fetus should be permissible only in narrowly defined circumstances.

  18. Fetal behavior in normal dichorionic twin pregnancy

    NARCIS (Netherlands)

    Mulder, E. J. H.; Derks, J. B.; de Laat, M. W. M.; Visser, G. H. A.

    2012-01-01

    Objectives: A prospective study was performed to compare fetal behavioral development in healthy dichorionic twins and singletons, and identify twin intra-pair associations (synchrony) of fetal movements and rest-activity cycles using different criteria to define synchrony. Subjects and methods:

  19. [Prenatal diagnosis and treatment of fetal choroid plexus cysts].

    Science.gov (United States)

    Liang, Mei-Ying; Wang, Hong-Bin; Huang, Xin; Wei, Yan-Qiu

    2007-09-01

    To discuss the clinical management and significance of the prenatal diagnosis of Fetal Choroid Plexus Cysts (CPC). From May 2004 to March 2007, 55 cases of fetal CPC diagnosed by B-ultrasound during second trimester were prospectively studied. Each case was studied regarding fetal chromosome karyotype, disappearance weeks of the cyst, the clinical outcome and follow-up results respectively. The cases were diagnosed during 16 - 25 gestational weeks. The diameters of the cysts varied from 0.2 cm to 2.4 cm. There were 25 cases of bilateral cysts and 30 cases of unilateral or 50 cases of isolated CPC and 5 cases of complicated CPC. The cysts of all cases who continued pregnancy disappeared before 28 weeks. Fetal chromosome karyotypes were obtained in 50 cases. Among them, two cases were 18-trisomy, and one case was 21-trisomy. Five cases were terminated pregnancy because of abnormal chromosome karyotype or malformation during second trimester. One neonate was diagnosed as ventricular septal defect among 50 cases of follow up. Among these six cases, three were from advanced-age pregnant women, five cases were with abnormal fetal structure and five cases were with the diameter of bilateral or unilateral cysts more than 1.0 cm. (1) Fetal CPC can be diagnosed during second trimester, and the majority disappear before 28 gestational weeks. (2) High risk factors for fetal abnormal chromosome karyotype may be: advanced-age pregnant women, abnormal structure of fetus, and the diameter of bilateral or unilateral cyst more than 1.0 cm. It is suggested that fetal CPC with the high risks should receive fetal chromosome karyotype test during pregnancy.

  20. Fetal Doppler to predict cesarean delivery for non-reassuring fetal status in the severe small-for-gestational-age fetuses of late preterm and term.

    Science.gov (United States)

    Jo, Ji Hye; Choi, Yong Hee; Wie, Jeong Ha; Ko, Hyun Sun; Park, In Yang; Shin, Jong Chul

    2018-03-01

    To evaluate the significance of fetal Doppler parameters in predicting adverse neonatal outcomes and the risk of cesarean delivery due to non-reassuring fetal status, in severe small for gestational age (SGA) fetuses of late preterm and term gestation. Fetal brain and umbilical artery (UmA) Doppler parameters of cerebroplacental ratio (CPR) and UmA pulsatility index (PI) were evaluated in a cohort of 184 SGA fetuses between 34 and 41 weeks gestational age, who were less than the 5th percentile. The risks of neonatal morbidities and cesarean delivery due to non-reassuring fetal status were analyzed. Univariate analysis revealed that abnormal CPR was significantly associated with cesarean delivery due to non-reassuring fetal status ( P =0.018), but not with neonatal morbidities. However, abnormal CPR did not increase the risk of cesarean delivery due to non-reassuring fetal status in multivariate logistic regression analysis. Abnormal CPR with abnormal PI of UmA was associated with low Apgar score at 1 minute ( P =0.048), mechanical ventilation ( P =0.013) and cesarean delivery due to non-reassuring fetal status ( P cesarean delivery for non-reassuring fetal status (adjusted odds ratio, 7.0; 95% confidence interval, 1.2-41.3; P =0.033), but did not increase risk of low Apgar score or mechanical ventilation in multivariate logistic regression analysis. Abnormal CPR with abnormal PI of UmA increases the risk of cesarean delivery for non-reassuring fetal status, in severe SGA fetuses of late preterm and term. Monitoring of CPR and PI of UmA can help guide management including maternal hospitalization and fetal monitoring.

  1. Maternal protein-energy malnutrition during early pregnancy in sheep impacts the fetal ornithine cycle to reduce fetal kidney microvascular development.

    OpenAIRE

    Dunford, L. J.; Sinclair, K. D.; Kwong, W. Y.; Sturrock, C.; Clifford, B. L.; Giles, T. C.; Gardner, D. S.

    2014-01-01

    This paper identifies a common nutritional pathway relating maternal through to fetal protein-energy malnutrition (PEM) and compromised fetal kidney development. Thirty-one twin-bearing sheep were fed either a control (n=15) or low-protein diet (n=16, 17 vs. 8.7 g crude protein/MJ metabolizable energy) from d 0 to 65 gestation (term, ?145 d). Effects on the maternal and fetal nutritional environment were characterized by sampling blood and amniotic fluid. Kidney development was characterized ...

  2. [Embryo-fetal diseases in multiple pregnancies].

    Science.gov (United States)

    Colla, F; Alba, E; Grio, R

    2001-04-01

    Embryo-fetal diseases are the consequence of prenatal (progenetic and metagenetic or environmental) and intranatal (of a traumatic, infective, toxic nature) pathological factors. In multiple pregnancies this complex etiopathogenesis also includes an altered didymous embriogenesis. This study aimed to evaluate the pathologies affecting the fetus in multiple pregnancy, a special biological situation leading to the potential onset of severe fetal and neonatal damage. The authors studied 205 patients with multiple pregnancies, including 199 bigeminal, 5 trigeminal and 1 quadrigeminal, admitted to the Department B of the Obstetrics and Gynecological Clinic of Turin University between 1989-1999. Possible embyro-fetal damage was examined using a chronological criterion: namely following the development of the multiple fetuses from the zygotic to the neonatal phase. Pregnancies were biamniotic bichorionic in 54% of cases, biamniotic monochorionic in 45% and monochorionic monoamniotic in 1%. There were a total of 154 (79.38%) premature births out of 194 and neonatal birth weight was always SGA (small for gestational age). 66.84% of newborns were LBW (<2500 g) and 7.14% were VLBW (<1500 g). Fetal mortality (2.29%) was higher than early neonatal mortality (1.53%). Perinatal mortality (3.82%) was three times higher than in all neonates from the same period (1.03%). The severe embryo-fetal and neonatal damage found in multiple pregnancies is a clinical reality that calls for adequate diagnostic and therapeutic measures, and above all specific medical and social prevention to limit maternal pathogenic risks.

  3. Lens artifacts in human fetal eyes - the challenge of interpreting the histomorphology of human fetal lenses.

    Science.gov (United States)

    Herwig, Martina C; Müller, Annette M; Klarmann-Schulz, Ute; Holz, Frank G; Loeffler, Karin U

    2014-01-01

    Evaluation of the lens, including cataractous changes, is often of paramount importance in the classification of fetal syndromes or forensic questions. On histology, the crystalline lens is - especially in fetal and infant eyes - an organ susceptible to numerous artifacts. Thus, the aim of our study was to study various factors (including fixatives) that might have an impact on lens histomorphology. Twenty eyes from ten fetuses (formalin fixation: n = 10, glutaraldehyde fixation: n = 10), matched for gestational age and abortion (spontaneous vs. induced), were investigated macroscopically and by light microscopy. Sections were stained with routine hematoxylin & eosin (H&E), and periodic acid schiff (PAS). The age of the fetal eyes ranged from 15 to 36 weeks of gestation. Lens artifacts were analyzed and compared to fetal and adult lenses with definitive cataractous changes. In addition, 34 eyes from 27 fetuses with trisomy 21 were investigated for lens changes. All lenses showed artifacts of varying extent, in particular globules, vacuoles, clefts, anterior/posterior capsular separation, subcapsular proteinaceous material, fragmentation of the lens capsule/epithelium, and a posterior umbilication. Glutaraldehyde-fixed lenses displayed less artifacts compared to those fixed in formalin. Slight differences in the appearance of artifacts were found dependent on the fixative (formaldehyde vs glutaraldehyde) and the kind of abortion (iatrogenous vs spontaneous). The gestational age did not have a significant influence on the type and extent of lens artifacts. The lenses from fetuses with trisomy 21 displayed similar lens artifacts with no specific findings. Alterations in fetal lens morphology are extremely frequent and variable. These artifacts have to be carefully taken into account when interpreting post-mortem findings. Thus, the postmortem diagnosis of a fetal cataract should be made with great caution, and should include, in adherence to our proposed

  4. Fetal and adult hematopoietic stem cells require beta1 integrin function for colonizing fetal liver, spleen, and bone marrow

    DEFF Research Database (Denmark)

    Potocnik, A J; Brakebusch, C; Fässler, R

    2000-01-01

    hematolymphoid differentiation potential in vitro and in fetal organ cultures but were unable to seed fetal and adult hematopoietic tissues. Adult beta1 integrin null HSCs isolated from mice carrying loxP-tagged beta1 integrin alleles and ablated for beta1 integrin expression by retroviral cre transduction......Homing of hematopoietic stem cells (HSCs) into hematopoietic organs is a prerequisite for the establishment of hematopoiesis during embryogenesis and after bone marrow transplantation. We show that beta1 integrin-deficient HSCs from the para-aortic splanchnopleura and the fetal blood had...

  5. The use of acoustic stimulation to inspect the fetal mouth

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Keun Young; Jun, Hyun Ah; Jang, Pong Rheem; Lee, Keung Hee [Hallym University College of Medicine, Seoul (Korea, Republic of); Nagey, David A. [The Johns Hopkins University, Baltimore (United States)

    2000-12-15

    The normal neonatal response to sound stimulus consists of a generalized paroxysmal startle reflex. We recently noted an increase in fetal movements, head turning, mouth opening, tongue protrusion, cheek motion, hand to head movement and fetal eye blinking subsequent to fetal vibroacoustic stimulation. These movements are thought to represent portions of a startle response. Evaluation of the fetal face is an essential part of routine sonographic examination and of a level II examination. The complexity of the face in combination with suboptimal positioning may make it difficult to obtain adequate images of the fetal mouth. The fetal mouth is especially difficult to examine if it remains closed. It appeared to us that approximately 50% of the time, fetuses may be seen touching their face and head with their hands. This action may make evaluation of the face more difficult because of the shadowing caused by the overlying bones of the hands. We hypothesized that if vibroacoustic stimulation brings about fetal mouth movement and opening and/or withdrawal of the fetal hand from the mouth, it may facilitate anatomic evaluation for cleft lip and palate. Sonographic examination of the fetal mouth is facilitated if the mouth is open or moving. This study was designed to determine whether acoustic stimulation of the fetus would cause it to move its mouth. 109 women with uncomplicated pregnancies between 20 and 39 weeks gestation consented.

  6. The use of acoustic stimulation to inspect the fetal mouth

    International Nuclear Information System (INIS)

    Lee, Keun Young; Jun, Hyun Ah; Jang, Pong Rheem; Lee, Keung Hee; Nagey, David A.

    2000-01-01

    The normal neonatal response to sound stimulus consists of a generalized paroxysmal startle reflex. We recently noted an increase in fetal movements, head turning, mouth opening, tongue protrusion, cheek motion, hand to head movement and fetal eye blinking subsequent to fetal vibroacoustic stimulation. These movements are thought to represent portions of a startle response. Evaluation of the fetal face is an essential part of routine sonographic examination and of a level II examination. The complexity of the face in combination with suboptimal positioning may make it difficult to obtain adequate images of the fetal mouth. The fetal mouth is especially difficult to examine if it remains closed. It appeared to us that approximately 50% of the time, fetuses may be seen touching their face and head with their hands. This action may make evaluation of the face more difficult because of the shadowing caused by the overlying bones of the hands. We hypothesized that if vibroacoustic stimulation brings about fetal mouth movement and opening and/or withdrawal of the fetal hand from the mouth, it may facilitate anatomic evaluation for cleft lip and palate. Sonographic examination of the fetal mouth is facilitated if the mouth is open or moving. This study was designed to determine whether acoustic stimulation of the fetus would cause it to move its mouth. 109 women with uncomplicated pregnancies between 20 and 39 weeks gestation consented.

  7. Comparison of pancuronium and vecuronium for fetal neuromuscular blockade during invasive procedures.

    Science.gov (United States)

    Watson, W J; Atchison, S R; Harlass, F E

    1996-01-01

    Neuromuscular blocking agents, used to arrest fetal motion for invasive intrauterine procedures, may cause temporary fetal heart rate changes. After 21 invasive procedures using either pancuronium bromide or vecuronium bromide, post-procedure fetal heart rate tracings were retrospectively compared. Pancuronium was associated with an increased fetal heart rate and decreased beat-to-beat variability for 2.5 hours after its use, whereas vecuronium caused no fetal heart rate changes. Vecuronium bromide offers advantages over pancuronium, because the decreased effect on the fetal heart allows better assessment of fetal well-being immediately following invasive intrauterine procedures.

  8. Fetal cardiac assessment

    International Nuclear Information System (INIS)

    Greene, K.R.

    1983-01-01

    The better understanding of fetal cardiovascular physiology coupled with improved technology for non-invasive study of the fetus now enable much more detailed assessment of fetal cardiac status than by heart rate alone. Even the latter, relatively simple, measurement contains much more information than was previously realized. It is also increasingly clear that no single measurement will provide the answer to all clinical dilemmas either on cardiac function or the welfare of the fetus as a whole. There are obvious clinical advantages in measuring several variables from one signal and the measurement of heart rate, heart rate variation and waveform from the ECG in labour is a potentially useful combination. Systolic time intervals or flow measurements could easily be added or used separately by combining real-time and Doppler ultrasound probes

  9. A novel method of mouse ex utero transplantation of hepatic progenitor cells into the fetal liver

    International Nuclear Information System (INIS)

    Shikanai, Mima; Asahina, Kinji; Iseki, Sachiko; Teramoto, Kenichi; Nishida, Tomohiro; Shimizu-Saito, Keiko; Ota, Masato; Eto, Kazuhiro; Teraoka, Hirobumi

    2009-01-01

    Avoiding the limitations of the adult liver niche, transplantation of hepatic stem/progenitor cells into fetal liver is desirable to analyze immature cells in a hepatic developmental environment. Here, we established a new monitor tool for cell fate of hepatic progenitor cells transplanted into the mouse fetal liver by using ex utero surgery. When embryonic day (ED) 14.5 hepatoblasts were injected into the ED14.5 fetal liver, the transplanted cells expressed albumin abundantly or α-fetoprotein weakly, and contained glycogen in the neonatal liver, indicating that transplanted hepatoblasts can proliferate and differentiate in concord with surrounding recipient parenchymal cells. The transplanted cells became mature in the liver of 6-week-old mice. Furthermore, this method was applicable to transplantation of hepatoblast-like cells derived from mouse embryonic stem cells. These data indicate that this unique technique will provide a new in vivo experimental system for studying cell fate of hepatic stem/progenitor cells and liver organogenesis.

  10. Consistent reconstruction of 4D fetal heart ultrasound images to cope with fetal motion.

    Science.gov (United States)

    Tanner, Christine; Flach, Barbara; Eggenberger, Céline; Mattausch, Oliver; Bajka, Michael; Goksel, Orcun

    2017-08-01

    4D ultrasound imaging of the fetal heart relies on reconstructions from B-mode images. In the presence of fetal motion, current approaches suffer from artifacts, which are unrecoverable for single sweeps. We propose to use many sweeps and exploit the resulting redundancy to automatically recover from motion by reconstructing a 4D image which is consistent in phase, space, and time. An interactive visualization framework to view animated ultrasound slices from 4D reconstructions on arbitrary planes was developed using a magnetically tracked mock probe. We first quantified the performance of 10 4D reconstruction formulations on simulated data. Reconstructions of 14 in vivo sequences by a baseline, the current state-of-the-art, and the proposed approach were then visually ranked with respect to temporal quality on orthogonal views. Rankings from 5 observers showed that the proposed 4D reconstruction approach significantly improves temporal image quality in comparison with the baseline. The 4D reconstructions of the baseline and the proposed methods were then inspected interactively for accessibility to clinically important views and rated for their clinical usefulness by an ultrasound specialist in obstetrics and gynecology. The reconstructions by the proposed method were rated as 'very useful' in 71% and were statistically significantly more useful than the baseline reconstructions. Multi-sweep fetal heart ultrasound acquisitions in combination with consistent 4D image reconstruction improves quality as well as clinical usefulness of the resulting 4D images in the presence of fetal motion.

  11. Fetal placental prostaglandin metabolism in the peripartum cow

    International Nuclear Information System (INIS)

    Gross, T.S.; Williams, W.F.; Lewis, G.S.

    1986-01-01

    Previous results demonstrate that fetal placental tissue synthesizes prostaglandin E (PGE) prior to parturition. When placental membranes do not separate postpartum, PGE synthesis is maintained, while prostaglandin F (PGF) synthesis predominates when the membranes separate. Concurrent with separation is a decline in fetal placental binucleate cell (BNC) numbers. These data suggest a fetal placental conversion of PGE to PGF. For this experiment, placentomes were collected at ten days prepartum (PRE, n=12) and within 1 hr postpartum. Nine of the postpartum animals had fetal membrane separation within 12 hr postpartum (S) and eight did not exhibit membrane separation (NS). For each placentome, fetal (villi) components were manually isolated and examined for the ability to interconvert 3 H labeled PGE 2 and PGF 2 . All villi were unable to convert PGE 2 to PGF 2 (P > .05). The PRE and NS villi were able to convert PGF 2 to PGE 2 (P 2 to PGE 2 (P 2 to PGE 2 also declines (P < .05). These data suggest that peripartum fetal placental tissue might synthesize PGF which is then converted to PGE. It is possible that the BNC are directly converting PGF to PGE or that they are modulating this conversion. Therefore, with a decline in BNC numbers, PGF synthesis would predominate

  12. Fetal programming and environmental exposures ...

    Science.gov (United States)

    Fetal programming is an enormously complex process that relies on numerous environmental inputs from uterine tissue, the placenta, the maternal blood supply, and other sources. Recent evidence has made clear that the process is not based entirely on genetics, but rather on a delicate series of interactions between genes and the environment. It is likely that epigenctic (“above the genome”) changes are responsible for modifying gene expression in the developing fetus, and these modifications can have long-lasting health impacts. Determining which epigenetic regulators are most vital in embryonic development will improve pregnancy outcomes and our ability to treat and prevent disorders that emerge later in life. “Fetal Programming and Environmental Exposures: Implications for Prenatal Care and Preterm Birth’ began with a keynote address by Frederick vom Saal, who explained that low-level exposure to endocrine disrupting chemicals (EDCs) perturbs hormone systems in utero and can have negative effects on fetal development. vom Saal presented data on the LOC bisphenol A (BPA), an estrogen-mimicking compound found in many plastics. He suggested that low-dose exposure to LOCs can alter the development process and enhance chances of acquiring adult diseases, such as breastcancer, diabetes, and even developmental disorders such as attention deficit disorder (ADHD).’ Fetal programming is an enormously complex process that relies on numerous environmental inputs

  13. Fetal programming of neuropsychiatric disorders.

    Science.gov (United States)

    Faa, Gavino; Manchia, Mirko; Pintus, Roberta; Gerosa, Clara; Marcialis, Maria Antonietta; Fanos, Vassilios

    2016-09-01

    Starting from the Developmental Origins of Health and Disease (DOHaD) hypotheses proposed by David Barker, namely fetal programming, in the past years, there is a growing evidence of the major role played by epigenetic factors during the intrauterine life and the perinatal period. Furthermore, it has been assessed that these factors can affect the health status in infancy and even in adulthood. In this review, we focus our attention on the fetal programming of the brain, analyzing the most recent literature concerning the epigenetic factors that can influence the development of neuropsychiatric disorders such as bipolar disorders, major depressive disorders, and schizophrenia. The perinatal epigenetic factors have been divided in two main groups: maternal factors and fetal factors. The maternal factors include diet, smoking, alcoholism, hypertension, malnutrition, trace elements, stress, diabetes, substance abuse, and exposure to environmental toxicants, while the fetal factors include hypoxia/asphyxia, placental insufficiency, prematurity, low birth weight, drugs administered to the mother or to the baby, and all factors causing intrauterine growth restriction. A better comprehension of the possible mechanisms underlying the pathogenesis of these diseases may help researchers and clinicians develop new diagnostic tools and treatments to offer these patients a tailored medical treatment strategy to improve their quality of life. Birth Defects Research (Part C) 108:207-223, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Expert systems for fetal assessment in labour

    NARCIS (Netherlands)

    Lutomski, J.E.; Meaney, S.; Greene, R.A.; Ryan, A.C.; Devane, D.

    2015-01-01

    BACKGROUND: Cardiotocography (CTG) records the fetal heart rate in relation to maternal uterine contractions and is one of the most common forms of fetal assessment during labour. Despite guidelines for CTG interpretation, substantial inter- and intra-observer variation in interpretation has been

  15. Non-invasive fetal electrocardiogram : analysis and interpretation

    NARCIS (Netherlands)

    Vullings, R.

    2010-01-01

    High-risk pregnancies are becoming more and more prevalent because of the progressively higher age at which women get pregnant. Nowadays about twenty percent of all pregnancies are complicated to some degree, for instance because of preterm delivery, fetal oxygen deficiency, fetal growth

  16. Ultrasonic Diagnosis of Fetal Ascites and Toxoplasmosis

    DEFF Research Database (Denmark)

    Blaakær, Jan

    1986-01-01

    The ultrasonic diagnosis of fetal ascites caused by Toxoplasma Gondii is presented. When a diagnosis of fetal ascites without obvious etiological malformation is established, toxoplasmosis should be suspected. A serological test should be performed, in view of the possibility of antenatal treatme...

  17. Feelings of women regarding end-of-life decision making after ultrasound diagnosis of a lethal fetal malformation.

    Science.gov (United States)

    Benute, Gláucia R G; Nomura, Roseli M Y; Liao, Adolfo W; Brizot, Maria de Lourdes; de Lucia, Mara C S; Zugaib, M

    2012-08-01

    this study investigated the feelings of women regarding end-of-life decision making after ultrasound diagnosis of a lethal fetal malformation. The aim of this study was to present the decision making process of women that chose for pregnancy termination and to present selected speeches of women about their feelings. open psychological interviews conducted by a psychologist immediately after the diagnosis of fetal malformation by ultrasound. Analysis of the results was performed through a content analysis technique. the study was carried out at a public university hospital in Brazil. 249 pregnant women who had received the diagnosis of a severe lethal fetal malformation. fetal anencephaly was the most frequent anomaly detected in 135 cases (54.3%). Termination of pregnancy was decided by 172 (69.1%) patients and legally authorised by the judiciary (66%). The reason for asking for termination was to reduce suffering in all of them. In the 77 women who chose not to terminate pregnancy (30.9%), the reasons were related to feelings of guilt (74%). the results support the importance of psychological counselling for couples when lethal fetal malformation is diagnosed. The act of reviewing moral and cultural values and elements of the unconscious provides assurance in the decision-making process and mitigates the risk of emotional trauma and guilt that can continue long after the pregnancy is terminated. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Complete maternal and fetal recovery after prolonged cardiac arrest.

    Science.gov (United States)

    Selden, B S; Burke, T J

    1988-04-01

    A case of complete maternal and fetal recovery after prolonged cardiac arrest from massive lidocaine overdose is presented. A 27-year-old woman at 15 weeks gestation had a complete neurologic recovery after 22 minutes of CPR, including 19 minutes of electromechanical dissociation and asystole, with normal fetal heart function and fetal motion confirmed by ultrasound immediately after resuscitation. The patient delivered a healthy and neurologically normal infant at 40 weeks gestation. This is the longest cardiac arrest in early pregnancy reported in the medical literature with normal maternal and fetal outcome.

  19. The Normal Fetal Pancreas.

    Science.gov (United States)

    Kivilevitch, Zvi; Achiron, Reuven; Perlman, Sharon; Gilboa, Yinon

    2017-10-01

    The aim of the study was to assess the sonographic feasibility of measuring the fetal pancreas and its normal development throughout pregnancy. We conducted a cross-sectional prospective study between 19 and 36 weeks' gestation. The study included singleton pregnancies with normal pregnancy follow-up. The pancreas circumference was measured. The first 90 cases were tested to assess feasibility. Two hundred ninety-seven fetuses of nondiabetic mothers were recruited during a 3-year period. The overall satisfactory visualization rate was 61.6%. The intraobserver and interobserver variability had high interclass correlation coefficients of of 0.964 and 0.967, respectively. A cubic polynomial regression described best the correlation of pancreas circumference with gestational age (r = 0.744; P pancreas circumference percentiles for each week of gestation were calculated. During the study period, we detected 2 cases with overgrowth syndrome and 1 case with an annular pancreas. In this study, we assessed the feasibility of sonography for measuring the fetal pancreas and established a normal reference range for the fetal pancreas circumference throughout pregnancy. This database can be helpful when investigating fetomaternal disorders that can involve its normal development. © 2017 by the American Institute of Ultrasound in Medicine.

  20. Fetal programming and eating disorder risk.

    Science.gov (United States)

    Jones, Candace; Pearce, Brad; Barrera, Ingrid; Mummert, Amanda

    2017-09-07

    Fetal programming describes the process by which environmental stimuli impact fetal development to influence disease development later in life. Our analysis summarizes evidence for the role of fetal programming in eating disorder etiology through review of studies demonstrating specific obstetric complications and later eating risk of anorexia or bulimia. Using Pubmed, we found thirteen studies investigating obstetric factors and eating disorder risk published between 1999 and 2016. We then discuss modifiable maternal risk factors, including nutrition and stress, that influence anorexia or bulimia risk of their offspring. Translation of these findings applies to preventative strategies by health organizations and physicians to provide optimal health for mothers and their children to prevent development of medical and psychiatric illnesses. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Middle cerebral artery flow velocity waveforms in fetal hypoxaemia.

    Science.gov (United States)

    Vyas, S; Nicolaides, K H; Bower, S; Campbell, S

    1990-09-01

    In 81 small-for-gestational age fetuses (SGA) colour flow imaging was used to identify the fetal middle cerebral artery for subsequent pulsed Doppler studies. Impedence to flow (pulsatility index; PI) was significantly lower, and mean blood velocity was significantly higher, than the respective reference ranges with gestation. Fetal blood sampling by cordocentesis was performed in all SGA fetuses and a significant quadratic relation was found between fetal hypoxaemia and the degree of reduction in the PI of FVWs from the fetal middle cerebral artery. Thus, maximum reduction in PI is reached when the fetal PO2 is 2-4 SD below the normal mean for gestation. When the oxygen deficit is greater there is a tendency for the PI to rise, and this presumably reflects the development of brain oedema.

  2. Long-term neurodevelopmental outcome after fetal therapy

    NARCIS (Netherlands)

    Klink, Jeanine Monica Maria van

    2015-01-01

    An increasing number of fetal diseases are being detected prior to birth due to major improvements in prenatal ultrasound examinations and the wide implementation of screening programs. For various diseases, fetal therapy may be a life-saving option or an alternative to postnatal treatment, to

  3. Fetal Arthrogryposis Secondary to a Giant Maternal Uterine Leiomyoma

    Directory of Open Access Journals (Sweden)

    José María Vila-Vives

    2012-01-01

    Full Text Available Arthrogryposis multiplex congenital is a rare condition defined as contractures in multiple joints at birth due to disorders starting in fetal life. Its etiology is associated with many different conditions and in many instances remains unknown. The final common pathway to all of them is decreased fetal movement (fetal akinesia due to an abnormal intrauterine environment. Causes of decreased fetal movements may be neuropathic abnormalities, abnormalities of connective tissue or muscle, intrauterine vascular compromise, maternal diseases, and space limitations within the uterus. When the cause of arthrogryposis is space limitations in uterus, the most common etiology is oligohydramnios. The same can result from intrauterine tumours as fibroids, although to our knowledge there are only two papers reporting cases of fetal deformities related to uterine leiomyomas. We describe a well-documented exceptional case of arthrogryposis associated with the presence of a large uterine fibroid. It could illustrate the importance of a careful and appropriate assessment of uterine fibroids before and in the course of a pregnancy considering that they can cause both serious maternal and fetal complications.

  4. Cross-hemispheric functional connectivity in the human fetal brain.

    Science.gov (United States)

    Thomason, Moriah E; Dassanayake, Maya T; Shen, Stephen; Katkuri, Yashwanth; Alexis, Mitchell; Anderson, Amy L; Yeo, Lami; Mody, Swati; Hernandez-Andrade, Edgar; Hassan, Sonia S; Studholme, Colin; Jeong, Jeong-Won; Romero, Roberto

    2013-02-20

    Compelling evidence indicates that psychiatric and developmental disorders are generally caused by disruptions in the functional connectivity (FC) of brain networks. Events occurring during development, and in particular during fetal life, have been implicated in the genesis of such disorders. However, the developmental timetable for the emergence of neural FC during human fetal life is unknown. We present the results of resting-state functional magnetic resonance imaging performed in 25 healthy human fetuses in the second and third trimesters of pregnancy (24 to 38 weeks of gestation). We report the presence of bilateral fetal brain FC and regional and age-related variation in FC. Significant bilateral connectivity was evident in half of the 42 areas tested, and the strength of FC between homologous cortical brain regions increased with advancing gestational age. We also observed medial to lateral gradients in fetal functional brain connectivity. These findings improve understanding of human fetal central nervous system development and provide a basis for examining the role of insults during fetal life in the subsequent development of disorders in neural FC.

  5. Cell-free fetal DNA in maternal plasma and noninvasive prenatal diagnosis DNA fetal libre en el plasma materno y diagnóstico prenatal no invasivo DNA livre fetal em plasma materno e diagnóstico pré-natal não invasivo

    Directory of Open Access Journals (Sweden)

    Ester Silveira Ramos

    2006-12-01

    Full Text Available The noninvasive nature of the detection of fetal DNA in the maternal circulation represents the greatest advantage over the conventional methods of prenatal diagnosis. The applications of this methodology involve the detection of the fetal sex, and diagnosis, intra-uterine treatment, and evaluation of the prognosis of many diseases. Fetal cells detected in the maternal circulation have also been shown to be implicated in autoimmune diseases and to represent a potential source of stem cells. On the other hand, with the introduction of a technology that detects the fetal sex as early as at 6-8 weeks of gestation, there is the possibility of early abortion based on sex selection for social purposes. This implies an ethical discussion about the question. The introduction of new noninvasive techniques of prenatal diagnosis and the knowledge of the Nursing Team regarding new methodologies can be of great benefit to the mother and her children, and can help the Genetic Counseling of the families.La naturaleza no invasiva de la investigación del DNA fetal en la circulación materna representa una ventaja importante con relación a los métodos convencionales de diagnóstico prenatal. El uso de esta metodología implica la determinación del sexo fetal y el diagnóstico, el tratamiento intra-útero y la evaluación del pronóstico en muchas enfermedades. Las células fetales detectadas en la circulación maternal también pueden ser implicadas en enfermedades autoinmunes y representar una fuente potencial de células madre. Por otra parte, con la introducción de una tecnología que detecte el sexo fetal entre 6-8 semanas de gestación, existe la posibilidad de aborto precoz basada en la selección del sexo para los propósitos sociales. Esto implica una discusión ética previa sobre este problema. La introducción de nuevas técnicas no invasivas de diagnóstico prenatal y el conocimiento del Equipo de Enfermería con respecto a las nuevas metodolog

  6. Maternal exercise, season and sex modify the human fetal circadian rhythm.

    Science.gov (United States)

    Sletten, Julie; Cornelissen, Germaine; Assmus, Jørg; Kiserud, Torvid; Albrechtsen, Susanne; Kessler, Jörg

    2018-05-13

    The knowledge on circadian rhythmicity is rapidly expanding. We aimed to define the longitudinal development of the circadian heart rate rhythm in the human fetus in an unrestricted, out-of-hospital setting, and to examine the effects of maternal physical activity, season and fetal sex. We recruited 48 women with low-risk singleton pregnancies. Using a portable monitor for continuous fetal electrocardiography, fetal heart rate recordings were obtained around gestational weeks 24, 28, 32 and 36. Circadian rhythmicity in fetal heart rate and fetal heart rate variation was detected by cosinor analysis; developmental trends were calculated by population-mean cosinor and multilevel analysis. For the fetal heart rate and fetal heart rate variation, a significant circadian rhythm was present in 122/123 (99.2%) and 116/121 (95.9%) of the individual recordings, respectively. The rhythms were best described by combining cosine waves with periods of 24 and 8 hours. With increasing gestational age, the magnitude of the fetal heart rate rhythm increased, and the peak of the fetal heart rate variation rhythm shifted from a mean of 14:25 (24 weeks) to 20:52 (36 weeks). With advancing gestation, the rhythm-adjusted mean value of the fetal heart rate decreased linearly in females (prhythm diversity was found in male fetuses, during higher maternal physical activity and during the summer season. The dynamic development of the fetal circadian heart rate rhythm during the second half of pregnancy is modified by fetal sex, maternal physical activity and season. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Fetal growth and developmental programming.

    Science.gov (United States)

    Galjaard, Sander; Devlieger, Roland; Van Assche, Frans A

    2013-01-01

    The environment in utero and in early neonatal life may induce a permanent response in the fetus and the newborn, leading to enhanced susceptibility to later diseases. This review concentrates on the role and mechanisms of events during the antenatal and immediate postnatal period resulting in later life diseases, concentrating on abnormal growth patterns of the fetus. Fetal overgrowth is related to exposure to a diabetic intra uterine environment, increasing the vulnerability to transgenerational obesity and hence an increased sensitivity to more diabetic mothers. This effect has been supported by animal data. Fetal growth restriction is complex due to malnutrition in utero, catch up growth due to a high caloric intake and low physical activity in later life. Metabolic changes and a transgenerational effect of intra uterine malnutrition has been supported by animal data. In recent years the discovery of alterations of the genome due to different influences during embryonic life, called epigenetics, has led to the phenomenon of fetal programming resulting in changing transgenerational metabolic effects.

  8. Fetal exposure in diagnostic radiology

    International Nuclear Information System (INIS)

    Baker, M.L.; Vandergrift, J.F.; Dalrymple, G.V.

    1979-01-01

    The problem of possible radiation damage to the fetus or embryo as a result of diagnostic radiography during pregnancy, particularly in the early stages, is discussed. Recommendations of therapeutic abortion after fetal exposure require an adequate knowledge of the doses involved. In the absence of actual dose measurements or estimates, approximate exposure levels may be determined from the literature. A summary of published values for radiography involving the lower abdomen is given. Data is also presented from a series of fetal exposures resulting mostly from routine diagnostic radiography when pregnancy was not known at the time but was established later. Results of actual dose measurements using a phantom and of dose calculations based on published values are in reasonable agreement indicating that literature values of dose provide a satisfactory alternative to measurement. These data suggest that diagnostic radiography rarely, if ever, results in fetal exposures high enough to justify therapeutic abortion. (author)

  9. A noise reconfigurable current-reuse resistive feedback amplifier with signal-dependent power consumption for fetal ECG monitoring

    NARCIS (Netherlands)

    Song, Shuang; Rooijakkers, M.J.; Harpe, P.; Rabotti, C.; Mischi, M.; Van Roermund, A.H.M.; Cantatore, E.

    2016-01-01

    This paper presents a noise-reconfigurable resistive feedback amplifier with current-reuse technique for fetal ECG monitoring. The proposed amplifier allows for both tuning of the noise level and changing the power consumption according to the signal properties, minimizing the total power

  10. Intrauterine fetal death and risk of shoulder dystocia at delivery.

    Science.gov (United States)

    Larsen, Sandra; Dobbin, Joanna; McCallion, Oliver; Eskild, Anne

    2016-12-01

    Vaginal delivery is recommended after intrauterine fetal death. However, little is known about the risk of shoulder dystocia in these deliveries. We studied whether intrauterine fetal death increases the risk of shoulder dystocia at delivery. In this population-based register study using the Medical Birth Registry of Norway, we included all singleton pregnancies with vaginal delivery of offspring in cephalic presentation in Norway during the period 1967-2012 (n = 2 266 118). Risk of shoulder dystocia was estimated as absolute risk (%) and odds ratio with 95% confidence interval. Adjustment was made for offspring birthweight (in grams). We performed sub-analyses within categories of birthweight (dystocia occurred in 1.1% of pregnancies with intrauterine fetal death and in 0.8% of pregnancies without intrauterine fetal death (p dystocia occurred in 14.6% of pregnancies with intrauterine fetal death and in 2.8% of pregnancies without intrauterine fetal death (p dystocia occurred in 57.1% of pregnancies with intrauterine fetal death and 9.6% of pregnancies without intrauterine fetal death (p dystocia at delivery, and the absolute risk of shoulder dystocia was particularly high if offspring birthweight was high and the mother had diabetes. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  11. Biglycan and decorin differentially regulate signaling in the fetal membranes

    Science.gov (United States)

    Wu, Zhiping; Horgan, Casie E.; Carr, Olivia; Owens, Rick T.; Iozzo, Renato V.; Lechner, Beatrice E.

    2014-01-01

    Preterm birth is the leading cause of newborn mortality in the United States and about one third of cases are caused by preterm premature rupture of fetal membranes, a complication that is frequently observed in patients with Ehlers-Danlos Syndrome. Notably, a subtype of Ehlers-Danlos Syndrome is caused by expression of abnormal biglycan and decorin proteoglycans. As compound deficiency of these two small leucine-rich proteoglycans is a model of preterm birth, we investigated the fetal membranes of Bgn−/−;Dcn−/− double-null and single-null mice. Our results showed that biglycan signaling supported fetal membrane remodeling during early gestation in the absence of concomitant changes in TGFβ levels. In late gestation, biglycan signaling acted in a TGFβ–dependent manner to aid in membrane stabilization. In contrast, decorin signaling supported fetal membrane remodeling at early stages of gestation in a TGFβ–dependent manner, and fetal membrane stabilization at later stages of gestation without changes in TGFβ levels. Furthermore, exogenous soluble decorin was capable of rescuing the TGFβ signaling pathway in fetal membrane mesenchymal cells. Collectively, these findings provide novel targets for manipulation of fetal membrane extracellular matrix stability and could represent novel targets for research on preventive strategies for preterm premature rupture of fetal membranes. PMID:24373743

  12. Fetal Urinary Tract Anomalies: Review of Pathophysiology, Imaging, and Management.

    Science.gov (United States)

    Mileto, Achille; Itani, Malak; Katz, Douglas S; Siebert, Joseph R; Dighe, Manjiri K; Dubinsky, Theodore J; Moshiri, Mariam

    2018-05-01

    Common fetal anomalies of the kidneys and urinary tract encompass a complex spectrum of abnormalities that can be detected prenatally by ultrasound. Common fetal anomalies of the kidneys and urinary tract can affect amniotic fluid volume production with the development of oligohydramnios or anhydramnios, resulting in fetal pulmonary hypoplasia and, potentially, abnormal development of other fetal structures. We provide an overview of common fetal anomalies of the kidneys and urinary tract with an emphasis on sonographic patterns as well as pathologic and postnatal correlation, along with brief recommendations for postnatal management. Of note, we render an updated classification of fetal abnormalities of the kidneys and urinary tract based on the presence or absence of associated urinary tract dilation. In addition, we review the 2014 classification of urinary tract dilation based on the Linthicum multidisciplinary consensus panel.

  13. Actual imaging time in fetal MRI

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Prayer, Daniela

    2012-01-01

    Objective: Safety issues in magnetic resonance imaging (MRI) are important, especially in fetal MRI. However, since basic data with respect of the effective exposure time in fetal MRI are not available, this study aimed to determine the actual imaging time during a fetal MRI study. Methods: 100 fetal MRI studies of singleton pregnancies performed on a 1.5 T system were analysed with respect to study duration (from starting the survey scan until the end of study), the number of sequences acquired, and the actual imaging time, which was calculated by adding up scan time of each sequence. Furthermore, each sequence type was analysed regarding the number of acquisitions, specific absorption rates (SAR), and duration. Results: Mean study duration was 34.6 min (range: 14–58 min; standard deviation (SD): 9.7 min), the average number of sequences acquired was 26.6 (range: 11–44, SD: 6.6). Actual scan time averaged 11.4 min (range: 4–19 min, SD: 4.0 min). Ultrafast T2-weighted and steady-state free-precession sequences accounted for 62.3% of actual scan time, and were distributed over the whole duration of the study. Conclusion: Actual imaging time only accounts for 33% of total study time and is not continuous. The remaining time is consumed by the preparation phases of the scanner, and is spent with planning sequences and the eventual repositioning of the coil and/or pregnant woman. These data may help to more accurately estimate the exposure to radiofrequency deposition and noise during fetal MRI studies.

  14. Magnetic resonance imaging (MRI) in obstetrics. II. Fetal anatomy.

    Science.gov (United States)

    Powell, M C; Worthington, B S; Buckley, J M; Symonds, E M

    1988-01-01

    Magnetic resonance imaging (MRI) was performed in 36 patients at between 10 and 38 weeks gestation to determine the fetal anatomy that could be identified at different gestations. Fetal motion significantly degraded the image quality in the first and second trimesters, but in the final trimester fetal anatomy was clearly demonstrated. T2 weighted sequences showed the fetal brain and lungs to have a high signal intensity. Shorter TR leading to a T1 weighting gave better resolution of the overall anatomy. MRI has revealed the potential for assessment of lung maturity and the growth-retarded fetus.

  15. Methods of fetal MR: beyond T2-weighted imaging

    International Nuclear Information System (INIS)

    Brugger, Peter C.; Stuhr, Fritz; Lindner, Christian; Prayer, Daniela

    2006-01-01

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body

  16. Methods of fetal MR: beyond T2-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Brugger, Peter C. [Center of Anatomy and Cell Biology, Integrative Morphology Group, Medical University of Vienna, Waehringerstrasse 13, 1090 Vienna (Austria)]. E-mail: peter.brugger@meduniwien.ac.at; Stuhr, Fritz [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Lindner, Christian [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria); Prayer, Daniela [Department of Radiology, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna (Austria)

    2006-02-15

    The present work reviews the basic methods of performing fetal magnetic resonance imaging (MRI). Since fetal MRI differs in many respects from a postnatal study, several factors have to be taken into account to achieve satisfying image quality. Image quality depends on adequate positioning of the pregnant woman in the magnet, use of appropriate coils and the selection of sequences. Ultrafast T2-weighted sequences are regarded as the mainstay of fetal MR-imaging. However, additional sequences, such as T1-weighted images, diffusion-weighted images, echoplanar imaging may provide further information, especially in extra- central-nervous system regions of the fetal body.

  17. Fetal MR imaging of Kniest dysplasia

    International Nuclear Information System (INIS)

    Yazici, Zeynep; Kline-Fath, Beth M.; Laor, Tal; Tinkle, Bradley T.

    2010-01-01

    We present a case of Kniest dysplasia, a rare form of the type II collagenopathies, with prenatal MRI. Sonography revealed only short limbs in the fetus. Fetal MRI findings included enlarged hyaline cartilaginous structures with abnormally high T2 signal intensity, delayed ossification of the pubic and ischial bones, and platyspondyly. By delineating the cartilaginous abnormalities, fetal MRI can contribute to the prenatal diagnosis of chondrodysplasias. (orig.)

  18. Fetal MR imaging of Kniest dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Zeynep [Uludag University, Faculty of Medicine, Department of Radiology, Gorukle (Turkey); Kline-Fath, Beth M.; Laor, Tal [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Tinkle, Bradley T. [Cincinnati Children' s Hospital Medical Center, Division of Human Genetics, Cincinnati, OH (United States)

    2010-03-15

    We present a case of Kniest dysplasia, a rare form of the type II collagenopathies, with prenatal MRI. Sonography revealed only short limbs in the fetus. Fetal MRI findings included enlarged hyaline cartilaginous structures with abnormally high T2 signal intensity, delayed ossification of the pubic and ischial bones, and platyspondyly. By delineating the cartilaginous abnormalities, fetal MRI can contribute to the prenatal diagnosis of chondrodysplasias. (orig.)

  19. Maternal endotoxin-induced fetal growth restriction in rats: Fetal responses in toll-like receptor

    Directory of Open Access Journals (Sweden)

    Banun Kusumawardani

    2012-09-01

    Full Text Available Background: Porphyromonas gingivalis as a major etiology of periodontal disease can produce virulence factor, lipopolysaccharide/LPS, which is expected to play a role in the intrauterine fetal growth. Trophoblast at the maternal-fetal interface actively participates in response to infection through the expression of a family of natural immune receptors, toll-like receptor (TLR. Purpose: the aims of study were to identify endotoxin concentration in maternal blood serum of Porphyromonas gingivalis-infected pregnant rats, to characterize the TLR-4 expression in trophoblast cells, and to determine its effect on fetal growth. Methods: Female rats were infected with live-Porphyromonas gingivalis at concentration of 2 x 109 cells/ml into subgingival sulcus area of the maxillary first molar before and/or during pregnancy. They were sacrified on 14th and 20th gestational day. Fetuses were evaluated for weight and length. Endotoxin was detected by limulus amebocyte lysate assay in the maternal blood serum. The TLR-4 expression in trophoblast cells was detected by immunohistochemistry. Fetal chromosome analysis

    DEFF Research Database (Denmark)

    Philip, J; Tabor, A; Bang, J

    1983-01-01

    The aim of the study was to investigate the rationale of the current indications for fetal chromosome analysis. 5372 women had 5423 amniocentesis performed, this group constituting a consecutive sample at the chromosome laboratory, Rigshospitalet, Copenhagen from March 1973 to September 1980 (Group...... A + B). Pregnant women 35 years of age, women who previously had a chromosomally abnormal child, families with translocation carriers or other heritable chromosomal disease, families where the father was 50 years or more and women in families with a history of Down's syndrome (group A), were compared...... to women having amniocentesis, although considered not to have any increased risk of fetal chromosome abnormality (1390 pregnancies, group B). They were also compared with 750 consecutive pregnancies in women 25-34 years of age, in whom all heritable diseases were excluded (group C). The risk of unbalanced...

  1. Feasibility of MRI of the fetal heart with balanced steady-state free precession sequence along fetal body and cardiac planes.

    Science.gov (United States)

    Saleem, Sahar N

    2008-10-01

    The purpose of this study was to evaluate the feasibility of imaging the fetal heart with a balanced steady-state free precession MRI sequence along the body and cardiac axes after inadequate echocardiography. After technically inadequate echocardiography, MRI was performed on 20 fetuses (mean gestational age, 24 weeks; range, 18-32 weeks) at risk of congenital heart disease. MRI was attempted along the three fetal body planes (n = 20) and cardiac axes (n = 3) without fetal sedation. The images were analyzed with an anatomic segmental approach. Each feature was classified as well visualized or poorly or not visualized. In each group, the Student's t test was used to assess the relation between visibility of fetal cardiac features and gestational age. Imaging was possible along the fetal body and cardiac axes. In the axial plane, a balanced four-chamber view was obtained in all fetuses, enabling evaluation of heart position, axis, chambers, and interventricular septum. The left and right ventricular outflow tracts were well visualized in 12 (60%) and nine (45%) of the fetuses, respectively; the three-vessel view was obtained in 10 fetuses (50%). With the combination of sagittal and coronal views, both ventricular outflow tracts were assessed in all fetuses. The superior and inferior venae cavae were identified in all fetuses, and at least one pulmonary vein was visualized in 17 fetuses (85%). There were no statistically significant differences between gestational age and lack of visualization of a cardiac feature that was attributed to fetal motion. MRI of the fetal heart with a steady-state free precession sequence in multiple planes and image analysis with an anatomic segmental approach to congenital heart disease are possible in situations that limit echocardiography.

  2. Sildenafil Citrate Increases Fetal Weight in a Mouse Model of Fetal Growth Restriction with a Normal Vascular Phenotype

    Science.gov (United States)

    Dilworth, Mark Robert; Andersson, Irene; Renshall, Lewis James; Cowley, Elizabeth; Baker, Philip; Greenwood, Susan; Sibley, Colin Peter; Wareing, Mark

    2013-01-01

    Fetal growth restriction (FGR) is defined as the inability of a fetus to achieve its genetic growth potential and is associated with a significantly increased risk of morbidity and mortality. Clinically, FGR is diagnosed as a fetus falling below the 5th centile of customised growth charts. Sildenafil citrate (SC, Viagra™), a potent and selective phosphodiesterase-5 inhibitor, corrects ex vivo placental vascular dysfunction in FGR, demonstrating potential as a therapy for this condition. However, many FGR cases present without an abnormal vascular phenotype, as assessed by Doppler measures of uterine/umbilical artery blood flow velocity. Thus, we hypothesized that SC would not increase fetal growth in a mouse model of FGR, the placental-specific Igf2 knockout mouse, which has altered placental exchange capacity but normal placental blood flow. Fetal weights were increased (by 8%) in P0 mice following maternal SC treatment (0.4 mg/ml) via drinking water. There was also a trend towards increased placental weight in treated P0 mice (P = 0.056). Additionally, 75% of the P0 fetal weights were below the 5th centile, the criterion used to define human FGR, of the non-treated WT fetal weights; this was reduced to 51% when dams were treated with SC. Umbilical artery and vein blood flow velocity measures confirmed the lack of an abnormal vascular phenotype in the P0 mouse; and were unaffected by SC treatment. 14C-methylaminoisobutyric acid transfer (measured to assess effects on placental nutrient transporter activity) per g placenta was unaffected by SC, versus untreated, though total transfer was increased, commensurate with the trend towards larger placentas in this group. These data suggest that SC may improve fetal growth even in the absence of an abnormal placental blood flow, potentially affording use in multiple sub-populations of individuals presenting with FGR. PMID:24204949

  3. Sildenafil citrate increases fetal weight in a mouse model of fetal growth restriction with a normal vascular phenotype.

    Directory of Open Access Journals (Sweden)

    Mark Robert Dilworth

    Full Text Available Fetal growth restriction (FGR is defined as the inability of a fetus to achieve its genetic growth potential and is associated with a significantly increased risk of morbidity and mortality. Clinically, FGR is diagnosed as a fetus falling below the 5(th centile of customised growth charts. Sildenafil citrate (SC, Viagra™, a potent and selective phosphodiesterase-5 inhibitor, corrects ex vivo placental vascular dysfunction in FGR, demonstrating potential as a therapy for this condition. However, many FGR cases present without an abnormal vascular phenotype, as assessed by Doppler measures of uterine/umbilical artery blood flow velocity. Thus, we hypothesized that SC would not increase fetal growth in a mouse model of FGR, the placental-specific Igf2 knockout mouse, which has altered placental exchange capacity but normal placental blood flow. Fetal weights were increased (by 8% in P0 mice following maternal SC treatment (0.4 mg/ml via drinking water. There was also a trend towards increased placental weight in treated P0 mice (P = 0.056. Additionally, 75% of the P0 fetal weights were below the 5(th centile, the criterion used to define human FGR, of the non-treated WT fetal weights; this was reduced to 51% when dams were treated with SC. Umbilical artery and vein blood flow velocity measures confirmed the lack of an abnormal vascular phenotype in the P0 mouse; and were unaffected by SC treatment. (14C-methylaminoisobutyric acid transfer (measured to assess effects on placental nutrient transporter activity per g placenta was unaffected by SC, versus untreated, though total transfer was increased, commensurate with the trend towards larger placentas in this group. These data suggest that SC may improve fetal growth even in the absence of an abnormal placental blood flow, potentially affording use in multiple sub-populations of individuals presenting with FGR.

  4. Assisted Reproduction Causes Reduced Fetal Growth Associated with Downregulation of Paternally Expressed Imprinted Genes That Enhance Fetal Growth in Mice.

    Science.gov (United States)

    Li, Bo; Chen, Shuqiang; Tang, Na; Xiao, Xifeng; Huang, Jianlei; Jiang, Feng; Huang, Xiuying; Sun, Fangzhen; Wang, Xiaohong

    2016-02-01

    Alteration of intrauterine growth trajectory is linked to metabolic diseases in adulthood. In mammalian and, specifically, human species, pregnancies through assisted reproductive technology (ART) are associated with changes in intrauterine growth trajectory. However, it is still unclear how ART alters intrauterine growth trajectory, especially reduced fetal growth in early to midgestation. In this study, using a mouse model, it was found that ART procedures reduce fetal and placental growth at Embryonic Day 10.5. Furthermore, ART leads to decreased methylation levels at H19, KvDMR1, and Snrpn imprinting control regions in the placentae, instead of fetuses. Furthermore, in the placenta, ART downregulated a majority of parentally expressed imprinted genes, which enhance fetal growth, whereas it upregulated a majority of maternally expressed genes which repress fetal growth. Additionally, the expression of genes that regulate placental development was also affected by ART. ART also downregulated a majority of placental nutrient transporters. Disruption of genomic imprinting and abnormal expression of developmentally and functionally relevant genes in placenta may influence the placental development and function, which affect fetal growth and reprogramming. © 2016 by the Society for the Study of Reproduction, Inc.

  5. Taquiarritmias supraventriculares no feto. Experiência de uma unidade de referência em cardiologia fetal Fetal supraventricular tachyarrhythmias. Experience of a fetal cardiology reference center

    Directory of Open Access Journals (Sweden)

    Paulo Zielinsky

    1998-05-01

    Full Text Available OBJETIVO: Avaliar a forma de apresentação, diagnóstico e tratamento das taquiarritmias supraventriculares fetais, através do relato de uma série de casos acompanhados em um centro terciário de cardiologia fetal. MÉTODOS: São descritos 25 casos de taquiarritmia supraventricular diagnosticados intra-útero, no período de janeiro/89 a outubro/97, em uma população compreendendo 3117 gestantes. RESULTADOS: Foram diagnosticados 17 casos de taquiarritmia supraventricular e 8 casos de flutter atrial fetal. As idades gestacionais variaram de 26 a 40 semanas. Doze fetos apresentavam hidropisia no momento do diagnóstico (6 com taquicardia supraventricular (TSV e 6 com flutter atrial. Quatro fetos com TSV apresentavam cardiopatias estruturais (dois casos de anomalia de Ebstein e dois com comunicação interventricular. Todos os fetos foram internados na Unidade de Cardiologia Fetal para monitorização e tratamento. Entre os 17 fetos com TSV, 12 apresentaram reversão da arritmia após administração de digoxina, mas esta medida não foi eficaz em nenhum paciente com flutter. Dois pacientes com TSV e seis com flutter necessitaram interrupção da gestação para cardioversão elétrica pós-natal. A mortalidade foi de 3/17 no grupo da TSV (incluindo dois pacientes com anomalia de Ebstein e de 0/8 no grupo com flutter. CONCLUSÃO: As taquiarritmias supraventriculares fetais são eventos raros na população geral. Entretanto, podem provocar insuficiência cardíaca e óbito intra-uterino. Como a resposta ao tratamento é satisfatória, tornam-se de extrema importância o diagnóstico precoce e o tratamento adequado.PURPOSE: To describe the presentation, diagnosis and treatment of fetal supraventricular tachyarrhythmias in a series of fetuses followed in a tertiary Fetal Cardiology Center. METHODS: Twenty-five fetuses with diagnosis of supraventricular tachyarrhytmia were reported from January 1989 to October 1997, among 3117 pregnant women

  6. 21 CFR 864.7455 - Fetal hemoglobin assay.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal hemoglobin assay. 864.7455 Section 864.7455 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7455 Fetal hemoglobin...

  7. Octreotide therapy and restricted fetal growth

    DEFF Research Database (Denmark)

    Geilswijk, Marianne; Andersen, Lise Lotte Torvin; Frost, Morten

    2017-01-01

    that octreotide treatment in pregnancy, as well as hypoglycemia in itself, may pose a risk of fetal growth restriction. During pregnancy, management of blood glucose levels in familial hyperinsulinemic hypoglycemia thus forms a medical dilemma. We report on pregnancy outcomes in a woman with symptomatic familial...... hyperinsulinemic hypoglycemia, type 3. During the patient's first pregnancy with a viable fetus octreotide treatment was instituted in gestational age 23 weeks to prevent severe hypoglycemic incidences. Fetal growth velocity declined, and at 37 weeks of gestation, intrauterine growth retardation was evident...... growth velocity was normal. We conclude that octreotide treatment during pregnancy may pose a risk of fetal growth restriction and warrants careful consideration. In some cases of familial hyperinsulinemic hypoglycemia, blood glucose levels can be successfully managed through diet only, also during...

  8. Fetal liver iron overload: the role of MR imaging

    International Nuclear Information System (INIS)

    Cassart, Marie; Avni, Freddy Efraim; Guibaud, Laurent; Molho, Marc; D'Haene, Nicky; Paupe, Alain

    2011-01-01

    To assess the potential role of MR imaging in the diagnosis of fetal liver iron overload. We reviewed seven cases of abnormal liver signal in fetuses referred to MR imaging in a context of suspected congenital infection (n = 2), digestive tract anomalies (n = 3) and hydrops fetalis (n = 2). The average GA of the fetuses was 31 weeks. The antenatal diagnoses were compared with histological data (n = 6) and postnatal work-up (n = 1). Magnetic resonance imaging demonstrated unexpected abnormal fetal liver signal suggestive of iron overload in all cases. The iron overload was confirmed on postnatal biopsy (n = 2) and fetopathology (n = 4). The final diagnosis was hepatic hemosiderosis (haemolytic anaemia (n = 2) and syndromal anomalies (n = 2)) and congenital haemochromatosis (n = 3). In all cases, the liver appeared normal on US. Magnetic resonance is the only imaging technique able to demonstrate liver iron overload in utero. Yet, the study outlines the fundamental role of MR imaging in cases of congenital haemochromatosis. The antenatal diagnosis of such a condition may prompt ante - (in the case of recurrence) or neonatal treatment, which might improve the prognosis. (orig.)

  9. Fetal liver iron overload: the role of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cassart, Marie; Avni, Freddy Efraim [Erasme Hospital, Medical imaging, Brussels, Brabant (Belgium); Guibaud, Laurent [Hopital femme mere enfant, Imagerie Pediatrique et Foetale, Lyon-Bron (France); Molho, Marc [C.H.I Poissy/St Germain-en-Laye, Imagerie Medicale, Poissy (France); D' Haene, Nicky [Erasme Hospital, Anatomopathology Department, Brussels (Belgium); Paupe, Alain [C.H.I Poissy/St Germain-en-Laye, Pediatrie, Poissy (France)

    2011-02-15

    To assess the potential role of MR imaging in the diagnosis of fetal liver iron overload. We reviewed seven cases of abnormal liver signal in fetuses referred to MR imaging in a context of suspected congenital infection (n = 2), digestive tract anomalies (n = 3) and hydrops fetalis (n = 2). The average GA of the fetuses was 31 weeks. The antenatal diagnoses were compared with histological data (n = 6) and postnatal work-up (n = 1). Magnetic resonance imaging demonstrated unexpected abnormal fetal liver signal suggestive of iron overload in all cases. The iron overload was confirmed on postnatal biopsy (n = 2) and fetopathology (n = 4). The final diagnosis was hepatic hemosiderosis (haemolytic anaemia (n = 2) and syndromal anomalies (n = 2)) and congenital haemochromatosis (n = 3). In all cases, the liver appeared normal on US. Magnetic resonance is the only imaging technique able to demonstrate liver iron overload in utero. Yet, the study outlines the fundamental role of MR imaging in cases of congenital haemochromatosis. The antenatal diagnosis of such a condition may prompt ante - (in the case of recurrence) or neonatal treatment, which might improve the prognosis. (orig.)

  10. Fetal MRI: An approach to practice: A review

    OpenAIRE

    Saleem, Sahar N.

    2013-01-01

    MRI has been increasingly used for detailed visualization of the fetus in utero as well as pregnancy structures. Yet, the familiarity of radiologists and clinicians with fetal MRI is still limited. This article provides a practical approach to fetal MR imaging. Fetal MRI is an interactive scanning of the moving fetus owed to the use of fast sequences. Single-shot fast spin-echo (SSFSE) T2-weighted imaging is a standard sequence. T1-weighted sequences are primarily used to demonstrate fat, cal...

  11. The Effect of Education of Fetal Movement Counting on Maternal-Fetal Attachment in the Pregnant Women: a Randomized Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Kobra Salehi

    2017-04-01

    Full Text Available Background Prenatal care is a good opportunity for evaluating and improving maternal-fetal attachment. In the present study the effect of early education of fetal movement counting in the second trimester on maternal-fetal attachment was evaluated. Materials and Methods 52 eligible pregnant women were selected through simple sampling and then randomly allocated into control (n=29, and intervention groups (n=23. First, demographic characteristics questionnaire and Cranely’s Maternal-Fetal Attachment Scale (MFAS, were completed by pregnant women. Face to face training about counting and recording the daily fetal movement was provided in the intervention group and from the 24th to 28th weeks of pregnancy, daily counting of fetal movements were conducted. Then at the end of the 28th week of pregnancy, MFAS was again completed by both groups. Data analysis was conducted using SPSS version16.0. Results The mean score of MFA scale in the intervention group was 86.63±11.62 and in the control group was 87.48±10.31 (total score of 120. No significant difference was observed between two groups. After the intervention, the mean score of MFA was increased to 96.30±10.81 in the intervention group and 88.64±10.31 in the control group. The difference was statistically significant between two groups (P

  12. Ovine fetal necrobacillosis

    DEFF Research Database (Denmark)

    Agerholm, J.S.; Boye, Mette; Aalbæk, B.

    2007-01-01

    were found in several tissues. Histologically, placental lesions were characterized by locally diffuse infiltration of neutrophils, closely associated with abundant small Gram-negative and FISH-positive rods, thrombosis and necrosis. Lesions in the fetal-maternal interface were multifocal and consisted...

  13. Fetal Alcohol Exposure

    Science.gov (United States)

    ... categories: 4 » Fetal Alcohol Syndrome (FAS) » Partial FAS (pFAS) » Alcohol-Related Neurodevelopmental Disorder (ARND) » Alcohol-Related Birth ... either prenatally, after birth, or both Partial FAS (pFAS) Partial FAS (pFAS) involves prenatal alcohol exposure, and ...

  14. Hypoglycemia and the origin of hypoxia-induced reduction in human fetal growth.

    Directory of Open Access Journals (Sweden)

    Stacy Zamudio

    2010-01-01

    Full Text Available The most well known reproductive consequence of residence at high altitude (HA >2700 m is reduction in fetal growth. Reduced fetoplacental oxygenation is an underlying cause of pregnancy pathologies, including intrauterine growth restriction and preeclampsia, which are more common at HA. Therefore, altitude is a natural experimental model to study the etiology of pregnancy pathophysiologies. We have shown that the proximate cause of decreased fetal growth is not reduced oxygen availability, delivery, or consumption. We therefore asked whether glucose, the primary substrate for fetal growth, might be decreased and/or whether altered fetoplacental glucose metabolism might account for reduced fetal growth at HA.Doppler and ultrasound were used to measure maternal uterine and fetal umbilical blood flows in 69 and 58 residents of 400 vs 3600 m. Arterial and venous blood samples from mother and fetus were collected at elective cesarean delivery and analyzed for glucose, lactate and insulin. Maternal delivery and fetal uptakes for oxygen and glucose were calculated.The maternal arterial - venous glucose concentration difference was greater at HA. However, umbilical venous and arterial glucose concentrations were markedly decreased, resulting in lower glucose delivery at 3600 m. Fetal glucose consumption was reduced by >28%, but strongly correlated with glucose delivery, highlighting the relevance of glucose concentration to fetal uptake. At altitude, fetal lactate levels were increased, insulin concentrations decreased, and the expression of GLUT1 glucose transporter protein in the placental basal membrane was reduced.Our results support that preferential anaerobic consumption of glucose by the placenta at high altitude spares oxygen for fetal use, but limits glucose availability for fetal growth. Thus reduced fetal growth at high altitude is associated with fetal hypoglycemia, hypoinsulinemia and a trend towards lactacidemia. Our data support that

  15. Fetal microchimerism in breast and colon cancer

    DEFF Research Database (Denmark)

    Kamper-Jørgensen, M; Biggar, R J; Stamper, Casey L

    2011-01-01

    1574 Background: Cells acquired by a woman from her baby that durably persist in her blood and tissues is known as fetal microchimerism (FMc). In women with breast cancer, frequency and quantity of FMc in blood and breast tissue is reduced compared to healthy women. Whether the absence of fetal...

  16. Longitudinal study of computerized cardiotocography in early fetal growth restriction

    NARCIS (Netherlands)

    Wolf, H.; Arabin, B.; Lees, Christoph C.; Oepkes, D.; Prefumo, Federico; Thilaganathan, B.; Todros, T.; Visser, G.H.A.; Bilardo, Caterina M.; Derks, J. B.; Diemert, A.; Duvekot, Johannes J.; Ferrazzi, E.; Frusca, T.; Hecher, K.; Marlow, N.; Martinelli, P.; Ostermayer, E.; Papageorghiou, Aris T.; Scheepers, Hubertina C. J.; Schlembach, D.; Schneider, K. T M; Valcamonico, A.; van Wassenaer-Leemhuis, A.; Ganzevoort, W.; Aktas, Ayse; Borgione, Silvia; Brezinka, Christoph; Calvert, Sandra; Chaoui, Rabih; Cornette, Jerome M J; Diehl, Thilo; van Eyck, Jim; Fratelli, Nicola; van Haastert, Inge Lot; Johnson, Samantha; Lobmaier, Silvia; Lopriore, Enrico; Mansi, Giuseppina; Missfelder-Lobos, Hannah; Martelli, Paola; Maso, Gianpaolo; Maurer-Fellbaum, Ute; Van Charante, Nico Mensing; De Tollenaer, Susanne Mulder; Moore, Tamanna; Napolitano, Raffaele; Oberto, Manuela; Ogge, Giovanna; van der Post, Joris Am; Preston, Lucy; Raimondi, Francesco; Reiss, Irwin K M; Rigano, Serena; Schuit, Ewoud; Skabar, Aldo; Spaanderman, Marc E.; Weisglas-Kuperus, Nynke; Zimmermann, Andrea

    2017-01-01

    Objectives: To explore whether, in early fetal growth restriction (FGR), the longitudinal pattern of fetal heart rate (FHR) short-term variation (STV) can be used to identify imminent fetal distress and whether abnormalities of FHR recordings are associated with 2-year infant outcome. Methods: The

  17. Performance of a wearable acoustic system for fetal movement discrimination.

    Directory of Open Access Journals (Sweden)

    Jonathan Lai

    Full Text Available Fetal movements (FM are a key factor in clinical management of high-risk pregnancies such as fetal growth restriction. While maternal perception of reduced FM can trigger self-referral to obstetric services, maternal sensation is highly subjective. Objective, reliable monitoring of fetal movement patterns outside clinical environs is not currently possible. A wearable and non-transmitting system capable of sensing fetal movements over extended periods of time would be extremely valuable, not only for monitoring individual fetal health, but also for establishing normal levels of movement in the population at large. Wearable monitors based on accelerometers have previously been proposed as a means of tracking FM, but such systems have difficulty separating maternal and fetal activity and have not matured to the level of clinical use. We introduce a new wearable system based on a novel combination of accelerometers and bespoke acoustic sensors as well as an advanced signal processing architecture to identify and discriminate between types of fetal movements. We validate the system with concurrent ultrasound tests on a cohort of 44 pregnant women and demonstrate that the garment is capable of both detecting and discriminating the vigorous, whole-body 'startle' movements of a fetus. These results demonstrate the promise of multimodal sensing for the development of a low-cost, non-transmitting wearable monitor for fetal movements.

  18. Metabolomics Application in Maternal-Fetal Medicine

    OpenAIRE

    Fanos, Vassilios; Atzori, Luigi; Makarenko, Karina; Melis, Gian Benedetto; Ferrazzi, Enrico

    2013-01-01

    Metabolomics in maternal-fetal medicine is still an “embryonic” science. However, there is already an increasing interest in metabolome of normal and complicated pregnancies, and neonatal outcomes. Tissues used for metabolomics interrogations of pregnant women, fetuses and newborns are amniotic fluid, blood, plasma, cord blood, placenta, urine, and vaginal secretions. All published papers highlight the strong correlation between biomarkers found in these tissues and fetal malformations, prete...

  19. Fetal growth restriction is associated with malaria in pregnancy

    DEFF Research Database (Denmark)

    Briand, Valérie; Saal, Jessica; Ghafari, Caline

    2016-01-01

    BACKGROUND: Few studies have evaluated the effect of malaria on intrauterine growth restriction on the basis of the fetal growth rate, rather than just the small-for-gestational age z score. Here, we assessed the impact of malaria on IUGR, using data from a longitudinal, ultrasonography-based fol......BACKGROUND: Few studies have evaluated the effect of malaria on intrauterine growth restriction on the basis of the fetal growth rate, rather than just the small-for-gestational age z score. Here, we assessed the impact of malaria on IUGR, using data from a longitudinal, ultrasonography......-based follow-up study of Beninese women. METHODS: A total of 1016 women were followed up from gestational week 17 to delivery. Malaria was detected every month. Women underwent ultrasonography 4 times for gestational age determination and fetal biometry. We assessed the effect of malaria on birth weight......-for-gestational age z score (n = 735 women) and fetal growth velocity (n = 664), defined as a change in fetal weight z score over time. RESULTS: Malaria was detected in 43% of women. Fetal growth velocity was negative overall, decreasing further at the end of the third trimester. Women with ≥2 malarial parasite...

  20. Prenatal diagnosis and management of fetal goiter caused by maternal Grave's disease.

    Science.gov (United States)

    Hadi, H A; Strickland, D

    1995-07-01

    We present a case of maternal Grave's disease associated with fetal goitrous hyperthyroidism. Fetal goiter was diagnosed by ultrasound and diagnosis of fetal hyperthyroidism was established by umbilical blood sampling. Fetus was successfully treated by increasing maternal propylthiouracil dosage. Fetal thyroid status was normal at birth. Role of sonography and umbilical blood sampling in management of fetal goiter complicated with maternal Grave's disease is discussed.

  1. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    Science.gov (United States)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  2. Fetal Cholelithiasis: A Diagnostic Update and a Literature Review

    Directory of Open Access Journals (Sweden)

    Stefania Triunfo

    2013-01-01

    Full Text Available Fetal gallstones and cholelithiasis, detected by routine third trimester ultrasound, have been described in the literature with controversial clinical significance. We report a case of fetal cholelithiasis detected at 35 weeks gestation during a routine scan. The diagnosis was performed using an integrated 2-dimensional (2-D and 3-dimensional (3-D ultrasound approach in order to obtain a better definition of the fetal gallbladder and its content. A neonatal follow-up was achieved. The present study has a twofold purpose: firstly, to update the diagnostic approach using the innovative 3-D modalities and secondly, to review the management of this condition during fetal and postnatal life.

  3. Fetal-Maternal Hemorrhage: A Case and Literature Review

    Directory of Open Access Journals (Sweden)

    Nino Solomonia

    2012-11-01

    Full Text Available Nearly all pregnancies include an insignificant hemorrhage of fetal blood into the maternal circulation. In some cases, the hemorrhage is large enough to compromise the fetus, resulting in fetal demise, stillbirth, or delivery of a severely anemic infant. Unfortunately, the symptoms of a significant fetal-maternal hemorrhage can be subtle, nonspecific, and difficult to identify at the time of the event. We present the case of a severely anemic newborn who was delivered in our facility with an extensive literature review.

  4. [The value of Doppler sonography in the detection of fetal hypoxia].

    Science.gov (United States)

    Aranyosi, János; Zatik, János; Juhász, A Gábor; Fülesdi, Béla; Major, Tamás

    2002-10-27

    Doppler ultrasound has become a part of routine antenatal fetal surveillance during the past two decades. It provides insight into the utero-placental and fetal arterial, venous circulation non-invasively. Doppler examination has a key role in the detection of hypoxic risk since abnormal blood flow patterns can be demonstrated before the clinical manifestation of fetal disorder. Doppler velocimetry facilitates judgment in the diagnosis, monitoring fetal well-being during pregnancy and labor, scheduling antenatal tests and timing delivery. Authors review the effects of chronic and acute hypoxia on fetal hemodynamics. On the basis of the present knowledge and experience a brief summary is given about the role of Doppler velocimetry in the early detection of hypoxic fetal jeopardy during pregnancy and labor.

  5. Fetal hydronephrosis: is there hope for consensus?

    Energy Technology Data Exchange (ETDEWEB)

    Toiviainen-Salo, Sanna; Dubois, Josee; Rypens, Francoise; Boisvert, Jacques; Perreault, Gilles; Decarie, Jean Claude; Filiatrault, Denis; Lapierre, Chantale; Miron, Marie-Claude; Bechard, Nancy [Department of Medical Imaging, Hopital Ste-Justine, 3175 Cote Ste-Catherine, H3T 1C5, Montreal, Quebec (Canada); Garel, Laurent; Grignon, Andree [Department of Medical Imaging, Hopital Ste-Justine, 3175 Cote Ste-Catherine, H3T 1C5, Montreal, Quebec (Canada); Department of Radiology, Universite de Montreal, 3175 Cote Ste-Catherine, H3T 1C5, Montreal, Quebec (Canada)

    2004-07-01

    This review article aims at summarizing the data regarding fetal and neonatal hydronephrosis, at correlating controversial data with the differences in the practice of obstetrical sonography from one country to another, and finally, at presenting our own criteria for fetal renal collecting system dilatation along with our own guidelines of postnatal investigation. (orig.)

  6. Fetal Gender and Several Cytokines Are Associated with the Number of Fetal Cells in Maternal Blood - An Observational Study

    DEFF Research Database (Denmark)

    Schlütter, Jacob Mørup; Kirkegaard, Ida; Petersen, Olav Bjørn

    2014-01-01

    OBJECTIVE: To identify factors influencing the number of fetal cells in maternal blood. METHODS: A total of 57 pregnant women at a gestational age of weeks 11-14 were included. The number of fetal cells in maternal blood was assessed in 30 ml of blood using specific markers for both enrichment...

  7. A means for fetal monitoring and reducing stillbirth

    African Journals Online (AJOL)

    2013-11-25

    Nov 25, 2013 ... Aims: This study aimed to determine maternal knowledge, behavior, and concerns about abnormal fetal movement in the third trimester of ..... diminution of gross fetal activity is suggestive of adverse pregnancy outcomes.[9,15 ...

  8. MRI of normal fetal brain development

    International Nuclear Information System (INIS)

    Prayer, Daniela; Kasprian, Gregor; Krampl, Elisabeth; Ulm, Barbara; Witzani, Linde; Prayer, Lucas; Brugger, Peter C.

    2006-01-01

    Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a symmetrical or asymmetrical environment, leading to structural differences that may be demonstrated by DW-anisotropy; (3) changes in non-structural qualities, such as the onset of a membrane potential in premyelinating axons. The latter process also influences the appearance of a structure on DW sequences. Thus, we will review the in vivo MR appearance of different maturational states of the fetal brain and relate these maturational states to anatomical, histological, and in vitro MRI data. Then, the development of the cerebral cortex, white matter, temporal lobe, and cerebellum will be reviewed, and the MR appearance of transient structures of the fetal brain will be shown. Emphasis will be placed on the appearance of the different structures with the various sequences. In addition, the possible utility of dynamic fetal sequences in assessing spontaneous fetal movements is discussed

  9. MRI of normal fetal brain development

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, Daniela [Department of Radiodiagnostics, Medical University of Vienna, Vienna (Austria)]. E-mail: Daniela.prayer@meduniwien.ac.at; Kasprian, Gregor [Department of Radiodiagnostics, Medical University of Vienna, Vienna (Austria); Krampl, Elisabeth [Department of Obstetrics and Gynecology, Medical University of Vienna, Vienna (Austria); Ulm, Barbara [Department of Prenatal Diagnosis, Medical University of Vienna, Vienna (Austria); Witzani, Linde [Department of Radiodiagnostics, Medical University of Vienna, Vienna (Austria); Prayer, Lucas [Diagnosezentrum Urania, Vienna (Austria); Brugger, Peter C. [Center of Anatomy and Cell Biology, Medical University of Vienna, Vienna (Austria)

    2006-02-15

    Normal fetal brain maturation can be studied by in vivo magnetic resonance imaging (MRI) from the 18th gestational week (GW) to term, and relies primarily on T2-weighted and diffusion-weighted (DW) sequences. These maturational changes must be interpreted with a knowledge of the histological background and the temporal course of the respective developmental steps. In addition, MR presentation of developing and transient structures must be considered. Signal changes associated with maturational processes can mainly be ascribed to the following changes in tissue composition and organization, which occur at the histological level: (1) a decrease in water content and increasing cell-density can be recognized as a shortening of T1- and T2-relaxation times, leading to increased T1-weighted and decreased T2-weighted intensity, respectively; (2) the arrangement of microanatomical structures to create a symmetrical or asymmetrical environment, leading to structural differences that may be demonstrated by DW-anisotropy; (3) changes in non-structural qualities, such as the onset of a membrane potential in premyelinating axons. The latter process also influences the appearance of a structure on DW sequences. Thus, we will review the in vivo MR appearance of different maturational states of the fetal brain and relate these maturational states to anatomical, histological, and in vitro MRI data. Then, the development of the cerebral cortex, white matter, temporal lobe, and cerebellum will be reviewed, and the MR appearance of transient structures of the fetal brain will be shown. Emphasis will be placed on the appearance of the different structures with the various sequences. In addition, the possible utility of dynamic fetal sequences in assessing spontaneous fetal movements is discussed.

  10. Fetal monitoring indications for delivery and 2-year outcome in 310 infants with fetal growth restriction delivered before 32 weeks' gestation in the TRUFFLE study

    NARCIS (Netherlands)

    Visser, G.H.A.; Bilardo, Caterina M.; Derks, J. B.; Ferrazzi, E.; Fratelli, Nicola; Frusca, T.; Ganzevoort, W.; Lees, Christoph C.; Napolitano, Raffaele; Todros, T.; Wolf, H.; Hecher, K.; Marlow, N.; Arabin, B.; Brezinka, C.; Diemert, A.; Duvekot, Johannes J.; Martinelli, P.; Ostermayer, E.; Papageorghiou, Aris T.; Schlembach, D.; Schneider, K. T M; Thilaganathan, B.; Valcamonico, A.; Aktas, Ayse; Borgione, Silvia; Chaoui, Rabih; Cornette, Jerome M J; Diehl, Thilo; van Eyck, J.; van Haastert, I. C.; Kingdom, J.C.; Lobmaier, Silvia; Lopriore, E.; Missfelder-Lobos, Hannah; Mansi, Giuseppina; Martelli, Paola; Maso, Gianpaolo; Marsal, K.; Maurer-Fellbaum, Ute; Mensing van Charante, N.; Mulder-De Tollenaer, Susanne; Oberto, Manuela; Oepkes, D.; Ogge, Giovanna; van der Post, Joris A. M.; Prefumo, Federico; Preston, Lucy; Raimondi, Francesco; Rattue, H.; Reiss, Irwin K M; Scheepers, L. S.; Skabar, Aldo; Spaanderman, M.; Thornton, J.G.; Valensise, H.; Weisglas-Kuperus, N.; Zimmermann, Andrea

    2017-01-01

    Objective: In the TRUFFLE (Trial of Randomized Umbilical and Fetal Flow in Europe) study on the outcome of early fetal growth restriction, women were allocated to one of three groups of indication for delivery according to the following monitoring strategies: (1) reduced fetal heart rate (FHR)

  11. Fundal Height: An Accurate Indicator of Fetal Growth?

    Science.gov (United States)

    ... could indicate conditions such as: Slow fetal growth (intrauterine growth restriction) A significantly larger than average baby (fetal macrosomia) ... Butler Tobah, M.D. Figueras F, et al. Intrauterine growth restriction: New concepts in antenatal surveillance, diagnosis, and management. ...

  12. Seric unconjugated Estrial as a prediction in fetal pulmonar maturity

    International Nuclear Information System (INIS)

    Velasquez F, A.Y.

    1986-07-01

    It was determined the effectivity and utility of the measurement of seric unconjugated estriol levels by radioimmunoassay, as a non invasive technique for determinating fetal lung maturity, correlating with Clement's test and optical density of the amniotic liquid. The study was made in 50 pregnant patients between the 37 and 52 weeks of gestation; samples of 5 to 8 cc of blood for the trial were collected. The evaluation of the new born was made by APGAR, gestational age by Ballard method and the presence of idiopatic respiratory difficulties by Silverman. (author)

  13. Fetal Programming of Obesity: Maternal Obesity and Excessive Weight Gain

    Directory of Open Access Journals (Sweden)

    Seray Kabaran

    2014-10-01

    Full Text Available The prevalence of obesity is an increasing health problem throughout the world. Maternal pre-pregnancy weight, maternal nutrition and maternal weight gain are among the factors that can cause childhood obesity. Both maternal obesity and excessive weight gain increase the risks of excessive fetal weight gain and high birth weight. Rapid weight gain during fetal period leads to changes in the newborn body composition. Specifically, the increase in body fat ratio in the early periods is associated with an increased risk of obesity in the later periods. It was reported that over-nutrition during fetal period could cause excessive food intake during postpartum period as a result of metabolic programming. By influencing the fetal metabolism and tissue development, maternal obesity and excessive weight gain change the amounts of nutrients and metabolites that pass to the fetus, thus causing excessive fetal weight gain which in turn increases the risk of obesity. Fetal over-nutrition and excessive weight gain cause permanent metabolic and physiologic changes in developing organs. While mechanisms that affect these organs are not fully understood, it is thought that the changes may occur as a result of the changes in fetal energy metabolism, appetite control, neuroendocrine functions, adipose tissue mass, epigenetic mechanisms and gene expression. In this review article, the effects of maternal body weight and weight gain on fetal development, newborn birth weight and risk of obesity were evaluated, and additionally potential mechanisms that can explain the effects of fetal over-nutrition on the risk of obesity were investigated [TAF Prev Med Bull 2014; 13(5.000: 427-434

  14. Epidemiology of Maternal and Fetal`s Burn in Iran: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Abbas Aghaei

    2018-02-01

    Full Text Available Background: Burn is one of the public health problems, especially in low-income and middle-income countries, and this problem is far more important for pregnant women and their fetus. There was no a systematic study to comprehensively review the epidemiology of Maternal and Fetal`s Burn inIran, this study was conducted for this purpose. Materials and Methods: In this systematic review and meta-analysis study, all related studies (Published in 2017 and earlier extracted by two independent groups from national and international databases (Magiran, SID, Web of Science, Medline, Scopus, etc.. Meta-analysis has been applied to obtain the overall outcomes of maternal and fetal mortality in pregnant women in Iran. Forest plot, τ2, and I2 tests are applied to evaluate heterogeneity, significance and its percentage, respectively. The analysis of meta-regression is applied because of the existence of heterogeneity. Publication bias is investigated by Funnel plot and Egger test. Results: The range of maternal and fetal mortality was 29.2% to 66.67% and 38.5% to 72.8%, respectively. Also, 48.4% and 54.2% were the overall outcome of maternal and fetal mortality based on meta-analysis, respectively. The highest maternal mortality is reported for pregnant women with Total Body Surface Area (TBSA over 50%, intentional burns, and acute respiratory failures. Finally, reduction of maternal mortality had a statistically significant relationship with passing time based on the univariate analysis. Conclusion:It can be inferred from our results that some hazards of burn in pregnant women are average age of 22-27 years, living in rural areas, low levels of socio-economic, low education level and being housewife. Also, according to meta-analysis results, about half of mothers and fetuses died in pregnant women as a result of burns in Iran.

  15. Effects of cord compression on fetal blood flow distribution and O2 delivery

    International Nuclear Information System (INIS)

    Itskovitz, J.; LaGamma, E.F.; Rudolph, A.M.

    1987-01-01

    The authors used the radionuclide microsphere technique in nine fetal lambs to examine the effect of partial cord compression on distribution of cardiac output and O 2 delivery to fetal organs and venous flow patterns. With a 50% reduction in umbilical blood flow the fraction of fetal cardiac output distributed to the brain, heart, carcass, kidneys, and gastrointestinal tract increased. Pulmonary blood flow fell. O 2 delivery to the brain and myocardium was maintained but was reduced to peripheral, renal, and gastrointestinal circulations. Hepatic blood flow decreased and O 2 delivery fell by 75%. The proportion of umbilical venous blood passing through the ductus venosus increased from 43.9 to 71.8%. The preferential distribution of ductus venosus blood flow through the foramen ovale was enhanced and the proportion of O 2 delivery to upper body organs derived from the ductus venosus increased. Abdominal inferior vena caval blood flow increased, and it was also preferentially distributed through the foramen ovale and constituted the major fraction of the arterial blood supply to the upper body organs. Thus cord compression modified the distribution of cardiac output and the patterns of venous returns in the fetus. This pattern of circulatory response differs from that observed with other causes of reduced O 2 delivery

  16. Optical coherence tomography: a potential tool to predict premature rupture of fetal membranes.

    Science.gov (United States)

    Micili, Serap C; Valter, Markus; Oflaz, Hakan; Ozogul, Candan; Linder, Peter; Föckler, Nicole; Artmann, Gerhard M; Digel, Ilya; Artmann, Aysegul T

    2013-04-01

    A fundamental question addressed in this study was the feasibility of preterm birth prediction based on a noncontact investigation of fetal membranes in situ. Although the phenomena of preterm birth and the premature rupture of the fetal membrane are well known, currently, there are no diagnostic tools for their prediction. The aim of this study was to assess whether optical coherence tomography could be used for clinical investigations of high-risk pregnancies. The thickness of fetal membranes was measured in parallel by optical coherence tomography and histological techniques for the following types of birth: normal births, preterm births without premature ruptures and births at full term with premature rupture of membrane. Our study revealed that the membrane thickness correlates with the birth type. Normal births membranes were statistically significantly thicker than those belonging to the other two groups. Thus, in spite of almost equal duration of gestation of the normal births and the births at full term with premature rupture, the corresponding membrane thicknesses differed. This difference is possibly related to previously reported water accumulation in the membranes. The optical coherence tomography results were encouraging, suggesting that this technology could be used in future to predict and distinguish between different kinds of births.

  17. In an in-vitro model using human fetal membranes, 17-α hydroxyprogesterone caproate is not an optimal progestogen for inhibition of fetal membrane weakening.

    Science.gov (United States)

    Kumar, Deepak; Moore, Robert M; Mercer, Brian M; Mansour, Joseph M; Mesiano, Sam; Schatz, Frederick; Lockwood, Charles J; Moore, John J

    2017-12-01

    The progestogen 17-α hydroxyprogesterone caproate (17-OHPC) is 1 of only 2 agents recommended for clinical use in the prevention of spontaneous preterm delivery, and studies of its efficacy have been conflicting. We have developed an in-vitro model to study the fetal membrane weakening process that leads to rupture in preterm premature rupture of the fetal membranes (pPROM). Inflammation/infection associated with tumor necrosis factor-α (TNF-α) induction and decidual bleeding/abruption associated thrombin release are leading causes of preterm premature rupture of the fetal membranes. Both agents (TNF-α and thrombin) cause fetal membrane weakening in the model system. Furthermore, granulocyte-macrophage colony-stimulating factor (GM-CSF) is a critical intermediate for both TNF-α and thrombin-induced fetal membrane weakening. In a previous report, we demonstrated that 3 progestogens, progesterone, 17-alpha hydroxyprogesterone (17-OHP), and medroxyprogesterone acetate (MPA), each inhibit both TNF-α- and thrombin-induced fetal membrane weakening at 2 distinct points of the fetal membrane weakening pathway. Each block both the production of and the downstream action of the critical intermediate granulocyte-macrophage colony-stimulating factor. The objective of the study was to characterize the inhibitory effects of 17-OHPC on TNF-α- and thrombin-induced fetal membrane weakening in vitro. Full-thickness human fetal membrane fragments from uncomplicated term repeat cesarean deliveries were mounted in 2.5 cm Transwell inserts and cultured with/without 17-alpha hydroxyprogesterone caproate (10 -9 to 10 -7 M). After 24 hours, medium (supernatant) was removed and replaced with/without the addition of tumor necrosis factor-alpha (20 ng/mL) or thrombin (10 U/mL) or granulocyte-macrophage colony-stimulating factor (200 ng/mL). After 48 hours of culture, medium from the maternal side compartment of the model was assayed for granulocyte-macrophage colony

  18. Low-complexity R-peak detection for ambulatory fetal monitoring

    International Nuclear Information System (INIS)

    Rooijakkers, Michael J; Rabotti, Chiara; Mischi, Massimo; Oei, S Guid

    2012-01-01

    Non-invasive fetal health monitoring during pregnancy is becoming increasingly important because of the increasing number of high-risk pregnancies. Despite recent advances in signal-processing technology, which have enabled fetal monitoring during pregnancy using abdominal electrocardiogram (ECG) recordings, ubiquitous fetal health monitoring is still unfeasible due to the computational complexity of noise-robust solutions. In this paper, an ECG R-peak detection algorithm for ambulatory R-peak detection is proposed, as part of a fetal ECG detection algorithm. The proposed algorithm is optimized to reduce computational complexity, without reducing the R-peak detection performance compared to the existing R-peak detection schemes. Validation of the algorithm is performed on three manually annotated datasets. With a detection error rate of 0.23%, 1.32% and 9.42% on the MIT/BIH Arrhythmia and in-house maternal and fetal databases, respectively, the detection rate of the proposed algorithm is comparable to the best state-of-the-art algorithms, at a reduced computational complexity. (paper)

  19. [Medical use of fetal cells and tissue: ethical aspects].

    Science.gov (United States)

    Wolff, H P

    1992-04-01

    After considering the moral status of the living and of the dead human fetus, the article examines various ethical arguments connected with the use of fetal remains following elective abortion: financial or humanitarian incentives for the termination of pregnancy, conflicts of interest between mother and user, authority over fetal remains and modality of donation and utilization of the fetus. To prevent improper use of fetal remains it is recommended: to separate completely the decisions relating to abortion (first) and to the subsequent use of fetal tissues (second); to obtain explicit informed consent from the mother, making it impossible for her to direct any specific use of the fetal tissues; to base decisions on the method and timing of an abortion on the mother's health care needs alone; to exclude those involved in the process of abortion from any use of the fetus; to protect the anonymity of donor and recipient through an intermediary (tissue bank).

  20. Low-complexity R-peak detection for ambulatory fetal monitoring.

    Science.gov (United States)

    Rooijakkers, Michael J; Rabotti, Chiara; Oei, S Guid; Mischi, Massimo

    2012-07-01

    Non-invasive fetal health monitoring during pregnancy is becoming increasingly important because of the increasing number of high-risk pregnancies. Despite recent advances in signal-processing technology, which have enabled fetal monitoring during pregnancy using abdominal electrocardiogram (ECG) recordings, ubiquitous fetal health monitoring is still unfeasible due to the computational complexity of noise-robust solutions. In this paper, an ECG R-peak detection algorithm for ambulatory R-peak detection is proposed, as part of a fetal ECG detection algorithm. The proposed algorithm is optimized to reduce computational complexity, without reducing the R-peak detection performance compared to the existing R-peak detection schemes. Validation of the algorithm is performed on three manually annotated datasets. With a detection error rate of 0.23%, 1.32% and 9.42% on the MIT/BIH Arrhythmia and in-house maternal and fetal databases, respectively, the detection rate of the proposed algorithm is comparable to the best state-of-the-art algorithms, at a reduced computational complexity.

  1. Assessment of fetal radiation dose to patients and staff in diagnostic radiology

    International Nuclear Information System (INIS)

    Osei, E.K.

    2000-07-01

    A major source of uncertainty in the estimation of fetal absorbed radiation dose is the influence of fetal size and position as these change with gestational age. Consequently, dose to the fetus is related to gestational age. Most studies of fetal dose estimation during pregnancy assume that the uterus dose is equal to fetal dose. These dose estimates do not take account of gestational age and individual fetal depth, factors which are significant when calculating dose. To establish both positional and size data for estimation of fetal absorbed dose from radiological examinations, the depths from the mother's anterior surface to the mid-line of the fetal head and abdomen were measured from ultrasound scans in 215 pregnant women. Depths were measured along a ray path projected in the anterior-posterior direction from the mother's abdomen. The fetal size was estimated from measurements of the fetal abdominal and head circumference, femur length and the biparietal diameter. The effects of fetal presentation, maternal bladder volume, placenta location, gestational age and maternal AP thickness on fetal depth and size were analysed. A Monte Carlo (MC) model was developed, and used to derive factors for converting dose-area product and free-in-air entrance surface dose from medical exposure of a pregnant patient to absorbed dose to the uterus/embryo, and for converting uterus dose to fetal dose in the later stages of pregnancy. Also presented are factors for converting thermoluminescence dosimeter reading from occupational exposure of a pregnant worker to equivalent dose to the fetus. The MC model was verified experimentally by direct measurement of uterus depth dose in a female Rando phantom, and also by comparison with other experimental work and MC results in the literature. The application of the various conversion factors is demonstrated by a review of the dose estimation process in 50 cases of fetal irradiation from medical exposures. (author)

  2. First and second trimester screening for fetal structural anomalies.

    Science.gov (United States)

    Edwards, Lindsay; Hui, Lisa

    2018-04-01

    Fetal structural anomalies are found in up to 3% of all pregnancies and ultrasound-based screening has been an integral part of routine prenatal care for decades. The prenatal detection of fetal anomalies allows for optimal perinatal management, providing expectant parents with opportunities for additional imaging, genetic testing, and the provision of information regarding prognosis and management options. Approximately one-half of all major structural anomalies can now be detected in the first trimester, including acrania/anencephaly, abdominal wall defects, holoprosencephaly and cystic hygromata. Due to the ongoing development of some organ systems however, some anomalies will not be evident until later in the pregnancy. To this extent, the second trimester anatomy is recommended by professional societies as the standard investigation for the detection of fetal structural anomalies. The reported detection rates of structural anomalies vary according to the organ system being examined, and are also dependent upon factors such as the equipment settings and sonographer experience. Technological advances over the past two decades continue to support the role of ultrasound as the primary imaging modality in pregnancy, and the safety of ultrasound for the developing fetus is well established. With increasing capabilities and experience, detailed examination of the central nervous system and cardiovascular system is possible, with dedicated examinations such as the fetal neurosonogram and the fetal echocardiogram now widely performed in tertiary centers. Magnetic resonance imaging (MRI) is well recognized for its role in the assessment of fetal brain anomalies; other potential indications for fetal MRI include lung volume measurement (in cases of congenital diaphragmatic hernia), and pre-surgical planning prior to fetal spina bifida repair. When a major structural abnormality is detected prenatally, genetic testing with chromosomal microarray is recommended over

  3. Fetal Ascites and Second Trimester Maternal Hepatitis C Virus Infection

    Directory of Open Access Journals (Sweden)

    Pei-Ying Ling

    2006-09-01

    Conclusion: Second trimester perinatal HCV infection with possible CMV coinfection associated with fetal ascites is a rare event. Fetal therapy resulting in a successful outcome has not been reported. Prompt fetal therapy with paracentesis in this case led to the delivery of a healthy term liveborn baby with anti-HCV seropositivity.

  4. Maternal and Fetal Acid-Base Chemistry: A Major Determinant of ...

    African Journals Online (AJOL)

    hanumantp

    Very small changes in pH may significantly affect the function of various fetal organ systems, such ... and fetal acid chemistry, clinical studies and case studies were undertaken. There is a .... the challenges of diagnosis and treatment of fetal hypoxia. Maternal ...... Blumenthal I. Cerebral palsy – Medicolegal aspects. J R Soc.

  5. Human fetal growth is constrained below optimal for perinatal survival

    NARCIS (Netherlands)

    Vasak, B.; Koenen, S. V.; Koster, M. P. H.; Hukkelhoven, C. W. P. M.; Franx, A.; Hanson, M. A.; Visser, GHA

    ObjectiveThe use of fetal growth charts assumes that the optimal size at birth is at the 50(th) birth-weight centile, but interaction between maternal constraints on fetal growth and the risks associated with small and large fetal size at birth may indicate that this assumption is not valid for

  6. Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being.

    Science.gov (United States)

    Martis, Ruth; Emilia, Ova; Nurdiati, Detty S; Brown, Julie

    2017-02-13

    The goal of fetal monitoring in labour is the early detection of a hypoxic baby. There are a variety of tools and methods available for intermittent auscultation (IA) of the fetal heart rate (FHR). Low- and middle-income countries usually have only access to a Pinard/Laënnec or the use of a hand-held Doppler device. Currently, there is no robust evidence to guide clinical practice on the most effective IA tool to use, timing intervals and length of listening to the fetal heart for women during established labour. To evaluate the effectiveness of different tools for IA of the fetal heart rate during labour including frequency and duration of auscultation. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (19 September 2016), contacted experts and searched reference lists of retrieved articles. All published and unpublished randomised controlled trials (RCTs) or cluster-RCTs comparing different tools and methods used for intermittent fetal auscultation during labour for fetal and maternal well-being. Quasi-RCTs, and cross-over designs were not eligible for inclusion. All review authors independently assessed eligibility, extracted data and assessed risk of bias for each trial. Data were checked for accuracy. We included three studies (6241 women and 6241 babies), but only two studies are included in the meta-analyses (3242 women and 3242 babies). Both were judged as high risk for performance bias due to the inability to blind the participants and healthcare providers to the interventions. Evidence was graded as moderate to very low quality; the main reasons for downgrading were study design limitations and imprecision of effect estimates. Intermittent Electronic Fetal Monitoring (EFM) using Cardiotocography (CTG) with routine Pinard (one trial)There was no clear difference between groups in low Apgar scores at five minutes (reported as < six at five minutes after birth) (risk ratio (RR) 0.66, 95% confidence interval (CI) 0.24 to 1.83, 633

  7. Maternal factors associated with fetal growth and birthweight are independent determinants of placental weight and exhibit differential effects by fetal sex.

    Directory of Open Access Journals (Sweden)

    Marie Cecilie Paasche Roland

    Full Text Available INTRODUCTION: Maternal nutritional and metabolic factors influence the developmental environment of the fetus. Virtually any nutritional factor in the maternal blood has to pass the placental membranes to reach the fetal blood. Placental weight is a commonly used measure to summarize placental growth and function. Placental weight is an independent determinant of fetal growth and birthweight and modifies the associations between maternal metabolic factors and fetal growth. We hypothesized that maternal factors known to be related to fetal growth, newborn size and body composition are determinants of placental weight and that effects of maternal metabolic factors on placental weight differ between the genders. METHODS: The STORK study is a prospective longitudinal study including 1031 healthy pregnant women of Scandinavian heritage with singleton pregnancies. Maternal determinants (parity, body mass index, gestational weight gain and fasting plasma glucose of placental weight were explored by linear regression models, stratified by fetal sex. RESULTS: Parity, maternal BMI, gestational weight gain and fasting glucose had positive effects on placental weight. There was a sex specific effect in these associations. Fasting glucose was significantly associated with placental weight in females but not in males. CONCLUSION: Maternal factors known to influence fetal growth, birthweight and neonatal body composition are determinants of placental weight. The effect of maternal factors on placental weight is influenced by sex as illustrated in the relation between maternal glucose and placental weight.

  8. Differing levels of excision repair in human fetal dermis and brain cells

    International Nuclear Information System (INIS)

    Gibson, R.E.; D'Ambrosio, S.M.; Ohio State Univ., Columbus

    1982-01-01

    The levels of DNA excision repair, as measured by unscheduled DNA synthesis (UDS) and the UV-endonuclease sensitive site assay, were compared in cells derived from human fetal brain and dermal tissues. The level of UDS induced following ultraviolet (UV) irradiation was found to be lower (approx. 60%) in the fetal brain cells than in fetal dermal cells. It was determined, using the UV-endonuclease sensitive site assay to confirm the UDS observation, that 50% of the dimers induced by UV in fetal dermal cells were repaired in 8 h. while only 15% were removed in the fetal brain cells during the same period of time. Even after 24 h. only 44% of the dimers induced by UV in the fetal brain cells were repaired, while 65% were removed in the dermal cells. These data suggest that cultured human fetal brain cells exhibit lower levels of excision repair compared to cultured human fetal dermal cells. (author)

  9. Fetal megacystis : prediction of spontaneous resolution and outcome

    NARCIS (Netherlands)

    Fontanella, F.; Duin, L.; Adama van Scheltema, P. N.; Cohen-Overbeek, T. E.; Pajkrt, E.; Bekker, M.; Willekes, C.; Bax, C. J.; Bilardo, C. M.

    2017-01-01

    Objectives: To investigate the natural history of fetal megacystis from diagnosis in utero to postnatal outcome, and to identify prognostic indicators of spontaneous resolution and postnatal outcome after resolution. Methods: This was a national retrospective cohort study. Fetal megacystis was

  10. Fetal megacystis : prediction of spontaneous resolution and outcome

    NARCIS (Netherlands)

    Fontanella, F; Duin, L; Adama van Scheltema, P N; Cohen-Overbeek, T E; Pajkrt, E; Bekker, M; Willekes, C; Bax, C J; Bilardo, C M

    2017-01-01

    Objectives To investigate the natural history of fetal megacystis from diagnosis in utero to postnatal outcome, and to identify prognostic indicators of spontaneous resolution and postnatal outcome after resolution. Methods This was a national retrospective cohort study. Fetal megacystis was defined

  11. Fetal magnetic resonance imaging of thoracic and abdominal malformations

    International Nuclear Information System (INIS)

    Woitek, R.; Asenbaum, U.; Furtner, J.; Prayer, D.; Brugger, P.C.

    2013-01-01

    Diagnosis and differential diagnosis of fetal thoracic and abdominal malformations. Ultrasound and magnetic resonance imaging (MRI). In cases of suspected pathologies based on fetal ultrasound MRI can be used for more detailed examinations and can be of assistance in the differential diagnostic process. Improved imaging of anatomical structures and of the composition of different tissues by the use of different MRI sequences. Fetal MRI has become a part of clinical routine in thoracic and abdominal malformations and is the basis for scientific research in this field. In cases of thoracic or abdominal malformations fetal MRI provides important information additional to ultrasound to improve diagnostic accuracy, prognostic evaluation and surgical planning. (orig.) [de

  12. Role of catecholamines in maternal-fetal stress transfer in sheep.

    Science.gov (United States)

    Rakers, Florian; Bischoff, Sabine; Schiffner, Rene; Haase, Michelle; Rupprecht, Sven; Kiehntopf, Michael; Kühn-Velten, W Nikolaus; Schubert, Harald; Witte, Otto W; Nijland, Mark J; Nathanielsz, Peter W; Schwab, Matthias

    2015-11-01

    We sought to evaluate whether in addition to cortisol, catecholamines also transfer psychosocial stress indirectly to the fetus by decreasing uterine blood flow (UBF) and increasing fetal anaerobic metabolism and stress hormones. Seven pregnant sheep chronically instrumented with uterine ultrasound flow probes and catheters at 0.77 gestation underwent 2 hours of psychosocial stress by isolation. We used adrenergic blockade with labetalol to examine whether decreased UBF is catecholamine mediated and to determine to what extent stress transfer from mother to fetus is catecholamine dependent. Stress induced transient increases in maternal cortisol and norepinephrine (NE). Maximum fetal plasma cortisol concentrations were 8.1 ± 2.1% of those in the mother suggesting its maternal origin. In parallel to the maternal NE increase, UBF decreased by maximum 22% for 30 minutes (P Fetal NE remained elevated for >2 hours accompanied by a prolonged blood pressure increase (P fetal NE and blood pressure increase and the shift toward anaerobic metabolism. We conclude that catecholamine-induced decrease of UBF is a mechanism of maternal-fetal stress transfer. It may explain the influence of maternal stress on fetal development and on programming of adverse health outcomes in later life especially during early pregnancy when fetal glucocorticoid receptor expression is limited. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Sonographic Measurement of Fetal Ear Length in Turkish Women with a Normal Pregnancy

    Directory of Open Access Journals (Sweden)

    Mucize Eriç Özdemir

    2014-12-01

    Full Text Available Background: Abnormal fetal ear length is a feature of chromosomal disorders. Fetal ear length measurement is a simple measurement that can be obtained during ultrasonographic examinations. Aims: To develop a nomogram for fetal ear length measurements in our population and investigate the correlation between fetal ear length, gestational age, and other standard fetal biometric measurements. Study Design: Cohort study. Methods: Ear lengths of the fetuses were measured in normal singleton pregnancies. The relationship between gestational age and fetal ear length in millimetres was analysed by simple linear regression. In addition, the correlation of fetal ear length measurements with biparietal diameter, head circumference, abdominal circumference, and femur length were evaluated.Ear length measurements were obtained from fetuses in 389 normal singleton pregnancies ranging between 16 and 28 weeks of gestation. Results: A nomogram was developed by linear regression analysis of the parameters ear length and gestational age. Fetal ear length (mm = y = (1.348 X gestational age-12.265, where gestational ages is in weeks. A high correlation was found between fetal ear length and gestational age, and a significant correlation was also found between fetal ear length and the biparietal diameter (r=0.962; p<0.001. Similar correlations were found between fetal ear length and head circumference, and fetal ear length and femur length. Conclusion: The results of this study provide a nomogram for fetal ear length. The study also demonstrates the relationship between ear length and other biometric measurements.

  14. Maternal and Fetal Acid-Base Chemistry: A Major Determinant of ...

    African Journals Online (AJOL)

    Very small changes in pH may significantly affect the function of various fetal organ systems, such as the central nervous system, and the cardiovascular system with associated fetal distress and poor Apgar score. Review of existing data on maternal-fetal acid-base balance in pregnancy highlight the factors that are ...

  15. [Fetal urology].

    Science.gov (United States)

    Jakobovits, Akos; Jakobovits, Antal

    2009-06-14

    Although it becomes vitally important only after birth, renal function already plays significant role in maintaining fetal metabolic equilibrium. The kidneys significantly contribute to production of amniotic fluid. Adequate amount of amniotic fluid is needed to stimulate the intrauterine fetal respiratory activity. Intrauterine breathing is essential for lung development. As a result, oligohydramnion is conducive to pulmonary hypoplasia. The latter may lead to neonatal demise soon after birth. In extrauterine life kidneys eliminate nitrogen containing metabolic byproducts. Inadequate renal function results therefore lethal uremia. Integrity of ureters and the urethra is essential for the maintenance of renal function. Retention of urine causes degeneration of the functional units of the kidneys and ensuing deterioration of renal function. Intrauterine kidney puncture or shunt procedure may delay this process in some cases. On the other hand, once renal function has been damaged, no therapy can restart it. Certain anomalies of renal excretory pathways may also be associated with other congenital abnormalities, making the therapeutic efforts pointless. Presence of these associated intrauterine defects makes early pregnancy termination a management alternative, as well as it affects favorably perinatal mortality rates.

  16. Association of fetal cranial shape with shoulder dystocia

    NARCIS (Netherlands)

    Belfort, M. A.; White, G. L.; Vermeulen, F. M.

    Objective To evaluate whether fetal cranial shape is related to shoulder dystocia. Methods We compared shoulder dystocia cases (n = 18) with controls (normal vaginal deliveries, n = 18) in a retrospective matched- pairs observational study. Subjects were matched for known maternal and fetal risk

  17. Fetal plasma erythropoietin concentration in severe growth retardation.

    Science.gov (United States)

    Snijders, R J; Abbas, A; Melby, O; Ireland, R M; Nicolaides, K H

    1993-02-01

    The aim of this study was to determine whether hypoxemia induces an increase in plasma erythropoietin concentration in human fetal life and, if so, whether this response stimulates fetal erythropoiesis. The plasma erythropoietin concentration in blood samples from 33 small-for-gestational-age fetuses at 26 to 38 weeks' gestation was measured. Measurements were compared with the reference range for gestation, and associations with PO2, pH, and erythroblast and erythrocyte counts were examined. The mean plasma erythropoietin concentration in the small-for-gestational-age fetuses was significantly increased, and the degree of increase was significantly associated both with fetal acidemia and, more strongly, with fetal erythroblastosis. Erythropoietin production in response to tissue hypoxia occurs from at least 26 weeks' gestation with measurable physiologic effects on erythropoiesis. Furthermore, more accurate assessment of tissue oxygenation may be obtained by measuring the erythroblast count rather than the blood pH.

  18. Fetal MRI and ultrasound of congenital CNS anomalies

    International Nuclear Information System (INIS)

    Pogledic, I.; Reith, W.; Meyberg-Solomayer, G.

    2013-01-01

    In the last decade the newest technologies, fetal magnetic resonance imaging (MRI) and 3D ultrasound, have given an insight into the minute structures of the fetal brain. However, without knowledge of the basic developmental processes the imaging is futile. Knowledge of fetal neuroanatomy corresponding to the gestational week is necessary in order to recognize pathological structures. Furthermore, a modern neuroradiologist should be acquainted with the three steps in the formation of the cerebral cortex: proliferation, migration and differentiation of neurons in order to be in a position to suspect that there is a pathology and start recognizing and discovering the abnormalities. The fetal MRI has become an important complementary method to ultrasound especially in cortical malformations when confirmation of the prenatal diagnosis is needed and additional pathologies need to be diagnosed. In this manner these two methods help in parental counseling and treatment planning. (orig.) [de

  19. A possible contribution of retinoids to regulation of fetal B lymphopoiesis.

    Science.gov (United States)

    Chen, Xinrong; Welner, Robert S; Kincade, Paul W

    2009-09-01

    We recently found that all trans retinoic acid (ATRA) accelerated B lymphocyte formation. In the current study, we address the question whether retinoids account for the rapid lymphopoiesis that is characteristic of fetal progenitors. Surprisingly, addition of ATRA to fetal liver cultures actually reduced B lymphopoiesis. A pan-retinoid receptor antagonist selectively suppressed lymphocyte formation from fetal and adult progenitors, suggesting some normal contribution of retinoids to this process. Consistent with this role, B lymphopoiesis was compromised in the marrow of mice with prolonged vitamin A deficiency. Recently identified B1 progenitors from adult marrow were similar to adult B2 progenitors in that their differentiation was stimulated by ATRA. The inhibitory response observed with fetal cells was seen when adult progenitors were exposed to high doses in culture or when adult mice were treated with ATRA for 2 wk. In addition to explosive lymphocyte generation, fetal progenitors tend to be less IL-7 dependent than their adult counterparts, but ATRA did not make fetal progenitors IL-7 independent. We conclude that all known categories of B lineage progenitors are responsive to retinoids and probably regulated by these compounds under physiological conditions. Retinoids may account in part for rapid differentiation in fetal life, but not all unique features of fetal progenitors.

  20. Telomere length and fetal programming: A review of recent scientific advances.

    Science.gov (United States)

    Whiteman, Valerie E; Goswami, Anjali; Salihu, Hamisu M

    2017-05-01

    We sought to synthesize a comprehensive literature review comprising recent research linking fetal programming to fetal telomere length. We also explored the potential effects fetal telomere length shortening has on fetal phenotypes. Utilizing the PubMed database as our primary search engine, we retrieved and reviewed 165 articles of published research. The inclusion criteria limited the articles to those that appeared within the last ten years, were pertinent to humans, and without restriction to language of publication. Our results showed that socio-demographic factors like age, sex, genetic inheritance, and acquired disease impact telomere length. Further, we found several maternal characteristics to be associated with fetal telomere length shortening, and these include maternal chemical exposure (eg, tobacco smoke), maternal stress during pregnancy, maternal nutritional and sleeping disorders during pregnancy as well as maternal disease status. Due to paucity of data, our review could not synthesize evidence directly linking fetal phenotypes to telomere length shortening. Although the research summarized in this review shows some association between determinants of intrauterine programming and fetal telomere length, there is still significant work that needs to be done to delineate the direct relationship of telomere attrition with specific fetal phenotypes. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Placental responses to changes in the maternal environment determine fetal growth

    Directory of Open Access Journals (Sweden)

    Kris Genelyn eDimasuay

    2016-01-01

    Full Text Available Placental responses to maternal perturbations are complex and remain poorly understood. Altered maternal environment during pregnancy such as hypoxia, stress, obesity, diabetes, toxins, altered nutrition, inflammation, and reduced utero-placental blood flow may influence fetal development, which can predispose to diseases later in life. The placenta being a metabolically active tissue responds to these perturbations by regulating the fetal supply of nutrients and oxygen and secretion of hormones into the maternal and fetal circulation. We have proposed that placental nutrient sensing integrates maternal and fetal nutritional cues with information from intrinsic nutrient sensing signaling pathways to balance fetal demand with the ability of the mother to support pregnancy by regulating maternal physiology, placental growth, and placental nutrient transport. Emerging evidence suggests that the nutrient-sensing signaling pathway mechanistic target of rapamycin (mTOR plays a central role in this process. Thus, placental nutrient sensing plays a critical role in modulating maternal-fetal resource allocation, thereby affecting fetal growth and the life-long health of the fetus.

  2. Antenatal management of recurrent fetal goitrous hyperthyroidism associated with fetal cardiac failure in a pregnant woman with persistent high levels of thyroid-stimulating hormone receptor antibody after ablative therapy.

    Science.gov (United States)

    Matsumoto, Tadashi; Miyakoshi, Kei; Saisho, Yoshifumi; Ishii, Tomohiro; Ikenoue, Satoru; Kasuga, Yoshifumi; Kadohira, Ikuko; Sato, Seiji; Momotani, Naoko; Minegishi, Kazuhiro; Yoshimura, Yasunori

    2013-01-01

    High titer of maternal thyroid-stimulating hormone receptor antibody (TRAb) in patients with Graves' disease could cause fetal hyperthyroidism during pregnancy. Clinical features of fetal hyperthyroidism include tachycardia, goiter, growth restriction, advanced bone maturation, cardiomegaly, and fetal death. The recognition and treatment of fetal hyperthyroidism are believed to be important to optimize growth and intellectual development in affected fetuses. We herein report a case of fetal treatment in two successive siblings showing in utero hyperthyroid status in a woman with a history of ablative treatment for Graves' disease. The fetuses were considered in hyperthyroid status based on high levels of maternal TRAb, a goiter, and persistent tachycardia. In particular, cardiac failure was observed in the second fetus. With intrauterine treatment using potassium iodine and propylthiouracil, fetal cardiac function improved. A high level of TRAb was detected in the both neonates. To the best of our knowledge, this is the first report on the changes of fetal cardiac function in response to fetal treatment in two siblings showing in utero hyperthyroid status. This case report illustrates the impact of prenatal medication via the maternal circulation for fetal hyperthyroidism and cardiac failure.

  3. Current approaches on non-invasive prenatal diagnosis: Prenatal genomics, transcriptomics, personalized fetal diagnosis

    Directory of Open Access Journals (Sweden)

    Tuba Günel

    2014-12-01

    Full Text Available Recent developments in molecular genetics improved our knowledge on fetal genome and physiology. Novel scientific innovations in prenatal diagnosis have accelerated in the last decade changing our vision immensely. Data obtained from fetal genomic studies brought new insights to fetal medicine and by the advances in fetal DNA and RNA sequencing technology novel treatment strategies has evolved. Non-invasive prenatal diagnosis found ground in genetics and the results are widely studied in scientific arena. When Lo and colleges proved fetal genetic material can be extracted from maternal plasma and fetal DNA can be isolated from maternal serum, the gate to many exciting discoveries was open. Microarray technology and advances in sequencing helped fetal diagnosis as well as other areas of medicine. Today it is a very crucial prerequisite for physicians practicing prenatal diagnosis to have a profound knowledge in genetics. Prevailing practical use and application of fetal genomic tests in maternal and fetal medicine mandates obstetricians to update their knowledge in genetics. The purpose of this review is to assist physicians to understand and update their knowledge in fetal genetic testing from maternal blood, individualized prenatal counseling and advancements on the subject by sharing our experiences as İstanbul University Fetal Nucleic Acid Research Group.

  4. Fetal autonomic cardiac response during pregnancy and labour

    NARCIS (Netherlands)

    Laar, van J.O.E.H.

    2012-01-01

    Timely recognition of fetal distress, during pregnancy and labour, in order to intervene adequately is of major importance to avoid neonatal morbidity and mortality. As discussed in chapter 1, the cardiotocogram (CTG) might be a useful screening test for fetal monitoring but it has insufficient

  5. Fetal endoscopic myelomeningocele closure preserves segmental neurological function

    NARCIS (Netherlands)

    Verbeek, Renate J.; Heep, Axel; Maurits, Natalia M.; Cremer, Reinhold; Hoving, Eelco W.; Brouwer, Oebele F.; Van der Hoeven, Johannes H.; Sival, Deborah A.

    AIM:   Our aim was to compare the effect of prenatal endoscopic with postnatal myelomeningocele closure (fetally operated spina bifida aperta [fSBA]) versus neonatally operated spina bifida aperta [nSBA]) on segmental neurological leg condition. METHOD:   Between 2003 and 2009, the fetal surgical

  6. Role of pancreatic polypeptide as a market of transplanted insulin-producing fetal pig cells.

    Science.gov (United States)

    Tuch, B E; Tabiin, M T; Casamento, F M; Yao, M; Georges, P; Amaratunga, A; Pinto, A N

    2001-01-01

    it is transplanted into mice. These findings may have relevance to fetal pancreatic tissue transplanted into humans if suitable techniques can be developed to separate pig from human PP.

  7. Modifications of erectile tissue components in the penis during the fetal period.

    Directory of Open Access Journals (Sweden)

    Carla B M Gallo

    Full Text Available The penile erectile tissue has a complex microscopic anatomy with important functions in the mechanism of penile erection. The knowledge of such structures is necessary for understanding the normal physiology of the adult penis. Therefore, it is important to know the changes of these penile structures during fetal development. This study aims to analyze the development of the main components of the erectile tissue, such as collagen, smooth muscle fibers and elastic system fibers, in human fetuses.We studied the penises of 56 human fetuses aged 13 to 36 weeks post-conception (WPC. We used histochemical and immunohistochemical staining, as well as morphometric techniques to analyze the collagen, smooth muscle fibers and elastic system fibers in the corpus cavernosum and in the corpus spongiosum. These elements were identified and quantified as percentage by using the Image J software (NIH, Bethesda, USA. From 13 to 36 WPC, in the corpus cavernosum, the amount of collagen, smooth muscle fibers and elastic system fibers varied from 19.88% to 36.60%, from 4.39% to 29.76% and from 1.91% to 8.92%, respectively. In the corpus spongiosum, the amount of collagen, smooth muscle fibers and elastic system fibers varied from 34.65% to 45.89%, from 0.60% to 11.90% and from 3.22% to 11.93%, respectively.We found strong correlation between the elements analyzed with fetal age, both in corpus cavernosum and corpus spongiosum. The growth rate of these elements was more intense during the second trimester (13 to 24 WPC of gestation, both in corpus cavernosum and in corpus spongiosum. There is greater proportional amount of collagen in the corpus spongiosum than in corpus cavernosum during all fetal period. In the corpus spongiosum, there is about four times more collagen than smooth muscle fibers and elastic system fibers, during all fetal period studied.

  8. Complementary role of magnetic resonance imaging in the study of the fetal urinary system.

    Science.gov (United States)

    Gómez Huertas, M; Culiañez Casas, M; Molina García, F S; Carrillo Badillo, M P; Pastor Pons, E

    2016-01-01

    Urinary system birth defects represent the abnormality most often detected in prenatal studies, accounting for 30% to 50% of all structural anomalies present at birth. The most common disorders are urinary tract dilation, developmental variants, cystic kidney diseases, kidney tumors, and bladder defects. These anomalies can present in isolation or in association with various syndromes. They are normally evaluated with sonography, and the use of magnetic resonance imaging (MRI) is considered only in inconclusive cases. In this article, we show the potential of fetal MRI as a technique to complement sonography in the study of fetal urinary system anomalies. We show the additional information that MRI can provide in each entity, especially in the evaluation of kidney function through diffusion-weighted sequences. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  9. Etiology of fetal and neonatal death is multifactorial

    OpenAIRE

    Huiza, Lilia; Pacora, Percy; Ayala, Máximo; Buzzio, Ytala

    2003-01-01

    Objetivo: Identificar los factores etiopatogénicos asociados a la muerte fetal y neonatal de una población de la ciudad de Lima, Perú. Lugar: Hospital San Bartolomé en Lima, entre 1 de enero de 1996 y 31 de diciembre de 2000. Material y métodos: Estudio retrospectivo de todos los casos de muerte fetal mayor de 20 semanas de gestación y muerte neonatal antes de los 28 días de nacimiento sometidos a estudio de autopsia y anatomía patológica. Resultados: La prevalencia de muerte fetal fue 1,68% ...

  10. Detection of congenital heart disease by fetal echocardiography

    International Nuclear Information System (INIS)

    Fayyaz, A.; Majeed, S.M.I.

    2013-01-01

    Objective: The objective of the study was to determine the sensitivity, specificity, accuracy and predictive value of fetal echocardiography in our set up using postnatal echocardiography as gold standard. Study Design: Validation study. Place and Duration of study: This is an ongoing study in the Radiology department of CMH Rawalpindi and Armed Forces Institute of Cardiology (AFIC) Rawalpindi and the data collected from January 2007 to Jan 2012 is presented. Patients and Methods: Two hundred eighty seven patients reported for fetal echocardiography. Two hundred twenty nine patients were subsequently included in the study. These included patients of all ages who reported to the Radiology department of CMH Rawalpindi for fetal echocardiography. Fetal echo was done on Toshiba Aplio with 3.5 MHz probe having Doppler facility. Post natal evaluation was done by a pediatric cardiologist. Results: There were 207 (90.4%) true negative cases, 15 (6.6%) true positive, 2 (0.9%) false positive and 6 (2.2%) false negative cases. The sensitivity, specificity, positive and negative predictive values were 75%, 99%, 88%, 97% respectively. Conclusion: Fetal echocardiography has high specificity, negative predictive values and accuracy and cases diagnosed as normal can reassure the parents about the normal cardiac status of the fetus. (author)

  11. Maternal Therapy with Ad.VEGF-A165 Increases Fetal Weight at Term in a Guinea-Pig Model of Fetal Growth Restriction.

    Science.gov (United States)

    Swanson, Anna M; Rossi, Carlo A; Ofir, Keren; Mehta, Vedanta; Boyd, Michael; Barker, Hannah; Ledwozyw, Agata; Vaughan, Owen; Martin, John; Zachary, Ian; Sebire, Neil; Peebles, Donald M; David, Anna L

    2016-12-01

    In a model of growth-restricted sheep pregnancy, it was previously demonstrated that transient uterine artery VEGF overexpression can improve fetal growth. This approach was tested in guinea-pig pregnancies, where placental physiology is more similar to humans. Fetal growth restriction (FGR) was attained through peri-conceptual nutrient restriction in virgin guinea pigs. Ad.VEGF-A 165 or Ad.LacZ (1 × 10 10 vp) was applied at mid-gestation via laparotomy, delivered externally to the uterine circulation with thermosensitive gel. At short-term (3-8 days post surgery) or at term gestation, pups were weighed, and tissues were sampled for vector spread analysis, VEGF expression, and its downstream effects. Fetal weight at term was increased (88.01 ± 13.36 g; n = 26) in Ad.VEGF-A 165 -treated animals compared with Ad.LacZ-treated animals (85.52 ± 13.00 g; n = 19; p = 0.028). The brain, liver, and lung weight and crown rump length were significantly larger in short-term analyses, as well as VEGF expression in transduced tissues. At term, molecular analyses confirmed the presence of VEGF transgene in target tissues but not in fetal samples. Tissue histology analysis and blood biochemistry/hematological examination were comparable with controls. Uterine artery relaxation in Ad.VEGF-A 165 -treated dams was higher compared with Ad.LacZ-treated dams. Maternal uterine artery Ad.VEGF-A 165 increases fetal growth velocity and term fetal weight in growth-restricted guinea-pig pregnancy.

  12. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study.

    Science.gov (United States)

    Seed, Mike; van Amerom, Joshua F P; Yoo, Shi-Joon; Al Nafisi, Bahiyah; Grosse-Wortmann, Lars; Jaeggi, Edgar; Jansz, Michael S; Macgowan, Christopher K

    2012-11-26

    We present the first phase contrast (PC) cardiovascular magnetic resonance (CMR) measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG). A validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30-39 weeks). Flow was measured in the major fetal vessels and indexed to the fetal weight. There was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96). Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO) 540 ± 101, main pulmonary artery (MPA) 327 ± 68, ascending aorta (AAo) 198 ± 38, superior vena cava (SVC) 147 ± 46, ductus arteriosus (DA) 220 ± 39,pulmonary blood flow (PBF) 106 ± 59,descending aorta (DAo) 273 ± 85, umbilical vein (UV) 160 ± 62, foramen ovale (FO)107 ± 54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60 ± 4, AAo37 ± 4, SVC 28 ± 7, DA 41 ± 8, PBF 19 ± 10, DAo50 ± 12, UV 30 ± 9, FO 21 ± 12. This study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.

  13. Feasibility of quantification of the distribution of blood flow in the normal human fetal circulation using CMR: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Seed Mike

    2012-11-01

    Full Text Available Abstract Background We present the first phase contrast (PC cardiovascular magnetic resonance (CMR measurements of the distribution of blood flow in twelve late gestation human fetuses. These were obtained using a retrospective gating technique known as metric optimised gating (MOG. Methods A validation experiment was performed in five adult volunteers where conventional cardiac gating was compared with MOG. Linear regression and Bland Altman plots were used to compare MOG with the gold standard of conventional gating. Measurements using MOG were then made in twelve normal fetuses at a median gestational age of 37 weeks (range 30–39 weeks. Flow was measured in the major fetal vessels and indexed to the fetal weight. Results There was good correlation between the conventional gated and MOG measurements in the adult validation experiment (R=0.96. Mean flows in ml/min/kg with standard deviations in the major fetal vessels were as follows: combined ventricular output (CVO 540±101, main pulmonary artery (MPA 327±68, ascending aorta (AAo 198±38, superior vena cava (SVC 147±46, ductus arteriosus (DA 220±39,pulmonary blood flow (PBF 106±59,descending aorta (DAo 273±85, umbilical vein (UV 160±62, foramen ovale (FO107±54. Results expressed as mean percentages of the CVO with standard deviations were as follows: MPA 60±4, AAo37±4, SVC 28±7, DA 41±8, PBF 19±10, DAo50±12, UV 30±9, FO 21±12. Conclusion This study demonstrates how PC CMR with MOG is a feasible technique for measuring the distribution of the normal human fetal circulation in late pregnancy. Our preliminary results are in keeping with findings from previous experimental work in fetal lambs.

  14. Fetal injury induced by Ca-DTPA in dogs

    International Nuclear Information System (INIS)

    Taylor, G.N.; Mays, C.W.

    1978-01-01

    The chelating agent Ca-DTPA, used to remove plutonium from the body, has produced fetal deaths and deformities in mice and rats. Damage is caused by depletion of essential trace elements, particularly zinc and manganese. It is suggested that a relationship may exist between the daily amount of Ca-DTPA,per kg body weight needed,to produce fetal toxicity and the daily intake of dietary zinc per kg body weight, and that this relationship could be used to predict fetal toxicity thresholds in various species. Results of a study on beagles are presented. Ca-DTPA treatment at the dose levels used in human therapy did not produce any symptoms in the pregnant dams but the fetuses showed depressed birth weight, abnormal hair colour due to pigmentary deficiency, brain damage and neutropenia. Extrapolation from dogs to humans predicts a toxic fetal dose less that one sixth of the daily dosage presently used for an adult woman, and emphasizes the hazards of Ca-DTPA therapy during pregnancy. (author)

  15. Normal renal development investigated with fetal MRI

    International Nuclear Information System (INIS)

    Witzani, Linde; Brugger, Peter Christian; Hoermann, Marcus; Kasprian, Gregor; Csapone-Balassy, Csilla; Prayer, Daniela

    2006-01-01

    Objective: To evaluate age-dependent changes in fetal kidney measurements with MRI. Patients and methods: Fetal MRI examinations were used to study the kidney length (218 fetuses), signal intensities of renal tissue, renal pelvis, and liver tissue on T2-weighted images (223 fetuses), and the whole-kidney apparent diffusion coefficient (107 fetuses). A 1.5 T superconducting unit with a phased array coil was used in patients from 16 to 39 weeks' gestation. The imaging protocol included T2-weighted single-shot fast spin-echo, T2-weighted balanced angiography and diffusion-weighted sequences. Slice thickness ranged from 3 to 5 mm. Results: Fetal kidney length as a function of gestational age was expressed by the linear regression: kidney length (mm) = 0.190 x gestational age (d) - 8.034 (R 2 0.883, p 2 /s) = 0.0302 x square (gestational age (d)) - 14.202 x gestational age (d) + 2728.6 (R 2 = 0.225, p < 0.001). Conclusion: The length, signal intensity on T2-weighted images, and apparent diffusion coefficient of the fetal kidney change significantly with gestational age. The presented data may help in the prenatal diagnosis of renal anomalies

  16. Fetal Alcohol Spectrum Disorders

    Science.gov (United States)

    Alcohol can harm your baby at any stage during a pregnancy. That includes the earliest stages, before ... can cause a group of conditions called fetal alcohol spectrum disorders (FASDs). Children who are born with ...

  17. Fetal liver T2* values: defining a standardized scale.

    Science.gov (United States)

    Goitein, Orly; Eshet, Yael; Hoffmann, Chen; Raviv-Zilka, Lisa; Salem, Yishay; Hamdan, Ashraf; Goitein, David; Kushnir, Tamar; Eshed, Iris; Di-Segni, Elio; Konen, Eli

    2013-12-01

    To define the normal T2* values of liver in the third trimester of pregnancy in normal fetuses. Multi-echo gradient echo T2* sequence was applied to the fetal abdomen in the axial plane in women undergoing a fetal MRI (1.5 Tesla [T], MRI system). A region of interest, best visualizing in the liver parenchyma was used for measurements. Studies were independently read by two experienced readers to assess intra- and interobserver variability. The study cohort included 46 pregnant women undergoing fetal MRI for any indication other than liver pathology evaluation. Three scans were excluded due to fetal motion. Average maternal and gestational age were 33 ± 4 years and 31.9 ± 3 weeks, respectively. Average T2* values were found to be 19.7 ± 7.4 ms. The intra- and interobserver agreement were very good: 0.93 and 0.8-0.084, respectively. T2* MRI allows noninvasive evaluation liver iron content in the third trimester fetus. Measured values at this stage of pregnancy are significantly lower compared with values cited in the literature for adults. This is of major importance in the correct diagnosis of fetal iron overload states. We propose this as the standard reference when evaluating fetal iron overload pathology. Copyright © 2013 Wiley Periodicals, Inc.

  18. Distinct functional programming of human fetal and adult monocytes.

    Science.gov (United States)

    Krow-Lucal, Elisabeth R; Kim, Charles C; Burt, Trevor D; McCune, Joseph M

    2014-03-20

    Preterm birth affects 1 out of 9 infants in the United States and is the leading cause of long-term neurologic handicap and infant mortality, accounting for 35% of all infant deaths in 2008. Although cytokines including interferon-γ (IFN-γ), interleukin-10 (IL-10), IL-6, and IL-1 are produced in response to in utero infection and are strongly associated with preterm labor, little is known about how human fetal immune cells respond to these cytokines. We demonstrate that fetal and adult CD14(+)CD16(-) classical monocytes are distinct in terms of basal transcriptional profiles and in phosphorylation of signal transducers and activators of transcription (STATs) in response to cytokines. Fetal monocytes phosphorylate canonical and noncanonical STATs and respond more strongly to IFN-γ, IL-6, and IL-4 than adult monocytes. We demonstrate a higher ratio of SOCS3 to IL-6 receptor in adult monocytes than in fetal monocytes, potentially explaining differences in STAT phosphorylation. Additionally, IFN-γ signaling results in upregulation of antigen presentation and costimulatory machinery in adult, but not fetal, monocytes. These findings represent the first evidence that primary human fetal and adult monocytes are functionally distinct, potentially explaining how these cells respond differentially to cytokines implicated in development, in utero infections, and the pathogenesis of preterm labor.

  19. Ultrasound Imaging of Mouse Fetal Intracranial Hemorrhage Due to Ischemia/Reperfusion

    Directory of Open Access Journals (Sweden)

    Kenichi Funamoto

    2017-05-01

    Full Text Available Despite vast improvement in perinatal care during the 30 years, the incidence rate of neonatal encephalopathy remains unchanged without any further Progress towards preventive strategies for the clinical impasse. Antenatal brain injury including fetal intracranial hemorrhage caused by ischemia/reperfusion is known as one of the primary triggers of neonatal injury. However, the mechanisms of antenatal brain injury are poorly understood unless better predictive models of the disease are developed. Here we show a mouse model for fetal intracranial hemorrhage in vivo developed to investigate the actual timing of hypoxia-ischemic events and their related mechanisms of injury. Intrauterine growth restriction mouse fetuses were exposed to ischemia/reperfusion cycles by occluding and opening the uterine and ovarian arteries in the mother. The presence and timing of fetal intracranial hemorrhage caused by the ischemia/reperfusion were measured with histological observation and ultrasound imaging. Protein-restricted diet increased the risk of fetal intracranial hemorrhage. The monitoring of fetal brains by ultrasound B-mode imaging clarified that cerebral hemorrhage in the fetal brain occurred after the second ischemic period. Three-dimensional ultrasound power Doppler imaging visualized the disappearance of main blood flows in the fetal brain. These indicate a breakdown of cerebrovascular autoregulation which causes the fetal intracranial hemorrhage. This study supports the fact that the ischemia/reperfusion triggers cerebral hemorrhage in the fetal brain. The present method enables us to noninvasively create the cerebral hemorrhage in a fetus without directly touching the body but with repeated occlusion and opening of the uterine and ovarian arteries in the mother.

  20. Maternal and fetal Acid-base chemistry: a major determinant of perinatal outcome.

    Science.gov (United States)

    Omo-Aghoja, L

    2014-01-01

    Very small changes in pH may significantly affect the function of various fetal organ systems, such as the central nervous system, and the cardiovascular system with associated fetal distress and poor Apgar score. Review of existing data on maternal-fetal acid-base balance in pregnancy highlight the factors that are associated with derangements of the acid-base status and the impact of the derangements on fetal outcome. Extensive search of electronic databases and manual search of journals for relevant literature on maternal and fetal acid chemistry, clinical studies and case studies were undertaken. There is a substantial reduction in the partial pressure of carbon dioxide (pCO2) in pregnancy. Adequate buffering prevents significant changes in maternal arterial pH. Normal fetal metabolism results in the production of acids which are buffered to maintain extracellular pH within a critical range. Fetal hypoxia can occur when maternal oxygenation is compromised, maternal perfusion of the placenta is reduced, or delivery of oxygenated blood from the placenta to the fetus is impeded. When adequate fetal oxygenation does not occur, metabolisms proceed along with an anaerobic pathway with production of organic acids, such as lactic acid. Accumulation of lactic acid can deplete the buffer system and result in metabolic acidosis with associated low fetal pH, fetal distress and poor Apgar score. There is a significant reduction in pCO2 in pregnancy. This change, however, does not result in a corresponding significant reduction in maternal arterial pH, because of adequate buffering. Very small changes in pH may cause significant derangement in fetal function and outcome.

  1. Effects of Cremation on Fetal Bones.

    Science.gov (United States)

    Zana, Michela; Magli, Francesca; Mazzucchi, Alessandra; Castoldi, Elisa; Gibelli, Daniele; Caccia, Giulia; Cornacchia, Francesca; Gaudio, Daniel A; Mattia, Mirko; Cattaneo, Cristina

    2017-09-01

    The charring process is a weak point of anthropological analysis as it changes bone morphology and reduces information obtainable, specially in fetuses. This experiment aims at verifying the conservation of fetal bones after cremation. A total of 3138 fetuses of unknown sex and age were used, deriving from legal and therapeutic abortions from different hospitals of Milan. Cremations took place in modern crematoria. Nine cremation events were analyzed, each ranging from 57 to 915 simultaneously cremated fetuses. During the cremations, 4356 skeletal remains were recovered, 3756 of which (86.2%) were morphologically distinguishable. All types of fetal skeletal elements were found, with the exception of some cranial bones. Only 3.4% of individuals could be detected after the cremation process, because of the prevalence of abortions under 12 lunar weeks. All fire alterations were observed and the results were statistically analyzed. This pilot study confirmed the possibility of preservation of fetal skeletal elements after cremation. © 2017 American Academy of Forensic Sciences.

  2. Mechanisms of Fetal Programming in Hypertension

    Directory of Open Access Journals (Sweden)

    John Edward Jones

    2012-01-01

    Full Text Available Events that occur in the early fetal environment have been linked to long-term health and lifespan consequences in the adult. Intrauterine growth restriction (IUGR, which may occur as a result of nutrient insufficiency, exposure to hormones, or disruptions in placental structure or function, may induce the fetus to alter its developmental program in order to adapt to the new conditions. IUGR may result in a decrease in the expression of genes that are responsible for nephrogenesis as nutrients are rerouted to the development of more essential organs. Fetal survival under these conditions often results in low birth weight and a deficit in nephron endowment, which are associated with hypertension in adults. Interestingly, male IUGR offspring appear to be more severely affected than females, suggesting that sex hormones may be involved. The processes of fetal programming of hypertension are complex, and we are only beginning to understand the underlying mechanisms.

  3. Thyroid hormones and fetal brain development.

    Science.gov (United States)

    Pemberton, H N; Franklyn, J A; Kilby, M D

    2005-08-01

    Thyroid hormones are intricately involved in the developing fetal brain. The fetal central nervous system is sensitive to the maternal thyroid status. Critical amounts of maternal T3 and T4 must be transported across the placenta to the fetus to ensure the correct development of the brain throughout ontogeny. Severe mental retardation of the child can occur due to compromised iodine intake or thyroid disease. This has been reported in areas of the world with iodine insufficiency, New Guinea, and also in mother with thyroid complications such as hypothyroxinaemia and hyperthyroidism. The molecular control of thyroid hormones by deiodinases for the activation of thyroid hormones is critical to ensure the correct amount of active thyroid hormones are temporally supplied to the fetus. These hormones provide timing signals for the induction of programmes for differentiation and maturation at specific stages of development. Understanding these molecular mechanisms further will have profound implications in the clinical management of individuals affected by abnormal maternal of fetal thyroid status.

  4. Trauma na gestante: análise da mortalidade materna e fetal

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Corsi

    Full Text Available Foram analisadas retrospectivamente 26 pacientes gestantes traumatizadas, num período de nove anos. A média de idade foi 23,7 anos (16-42. A idade gestacional variou de dez a quarenta semanas (média 21,5 semanas; a maioria (46,1% no segundo trimestre. O mecanismo predominante (65,3% foi o trauma abdominal fechado por acidente automobilístico (atropelamento ou colisão. Na admissão, oito (30,7% pacientes apresentavam alterações hemodinâmicas. Seis doentes (23,0% apresentavam sangramento vaginal e, destas, quatro estavam hemodinamicamente normais. Analisamos a mortalidade materna, a mortalidade fetal e suas causas. Comparamos também a mediana dos valores do RTS e TRISS entre os grupos, sobrevida materno-fetal, sobrevida materna e óbito materno-fetal. Todas as gestantes admitidas com sangramento vaginal apresentaram óbito fetal. A mortalidade materna foi de 11,5%, por choque hemorrágico. A mortalidade fetal foi de 30,7%, sendo que 37,5% destes óbitos foram provocados pela morte materna. A principal causa de mortalidade fetal foi o descolamento de placenta (50,0%. Os índices de trauma, RTS e TRISS, foram significativamente menor (p=0,0025 e p<0,0001 no grupo óbito materno-fetal, porém esses índices não apresentaram valor prognóstico na mortalidade fetal.

  5. Principle study on the signal connection at transabdominal fetal pulse oximetry

    Directory of Open Access Journals (Sweden)

    Böttrich Marcel

    2016-09-01

    Full Text Available Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling.

  6. Fatores maternos associados ao peso fetal estimado pela ultra-sonografia Maternal factors associated with fetal weight estimated by ultrasonography

    Directory of Open Access Journals (Sweden)

    Adriana Suely de Oliveira Melo

    2008-09-01

    Full Text Available OBJETIVO: avaliar o efeito de variáveis maternas, socioeconômicas e obstétricas, assim como a presença de incisuras na 20ª e na 24ª semana, sobre o peso fetal estimado no final da gravidez (36ª semana em gestantes atendidas pelo Programa Saúde da Família em uma cidade do interior do Nordeste do Brasil. MÉTODOS: estudo longitudinal incluindo 137 gestantes. As gestantes foram acompanhadas a cada quatro semanas para aferição das condições clínicas, socioeconômicas e obstétricas, incluindo o peso materno. As artérias uterinas foram avaliadas pelo Doppler na 20ª e 24ª semana, o peso fetal e o índice de líquido amniótico (ILA foram determinados na 36ª semana. O estado nutricional materno inicial foi determinado pelo índice de massa corpórea (IMC, classificando-se as gestantes como com baixo peso, eutróficas, com sobrepeso e obesas. O ganho ponderal durante a gestação foi avaliado de acordo com o estado nutricional inicial, sendo ao final do segundo e terceiro trimestre classificado em ganho ponderal insuficiente, adequado e excessivo. Foi realizada análise de variância para avaliar a associação do peso fetal estimado na 36ª semana com as variáveis preditoras, ajustada por regressão linear múltipla. RESULTADOS: observou-se associação entre peso fetal estimado na 36ª semana e idade da mãe (p=0,02, trabalho materno (p=0,02, estado nutricional inicial (p=0,04, ganho ponderal no segundo trimestre (p=0,01, presença de incisuras nas artérias uterinas (p=0,02 e ILA (p=0,007. Os principais fatores associados ao peso fetal estimado na 36ª semana, após a análise de regressão múltipla, foram: IMC no início da gravidez, ganho ponderal no segundo trimestre, ILA e tabagismo. CONCLUSÕES: o peso fetal no presente estudo associou-se positivamente ao estado nutricional materno inicial, ao ganho ponderal no segundo trimestre, ao volume do líquido amniótico e negativamente ao hábito de tabagismo.PURPOSE: to evaluate the

  7. Fatores maternos e perinatais relacionados à macrossomia fetal Maternal and perinatal factors related to fetal macrosomia

    Directory of Open Access Journals (Sweden)

    José Mauro Madi

    2006-04-01

    Full Text Available OBJETIVO: identificar fatores maternos e perinatais relacionados a fetos com peso igual ou maior do que 4.000 g no nascimento. MÉTODOS: estudo de corte transversal, de 411 casos consecutivos de macrossomia fetal, ocorridos no período de março de 1998 a março de 2005. Compararam-se os dados obtidos aos de 7.349 casos de fetos com peso entre 2.500 e 3.999 g ao nascimento, ocorridos no mesmo período. Foram analisadas variáveis maternas (idade, paridade, diabete melito, ocorrência de parto cesáreo, mecônio, desproporção feto-pélvica, principais indicações das cesáreas e perinatais (ocorrência de tocotraumatismo, índice de Apgar inferior a sete no 1º e 5º minuto, natimortalidade, neomortalidade precoce, necessidade de internação na Unidade de Tratamento Intensivo Neonatal. As avaliações estatísticas foram realizadas com o teste não paramétrico do chi2 com a correção de Yates e com o teste t de Student. Adotou-se o nível de significância de pPURPOSE: to identify maternal and perinatal factors related to neonates with birthweight >4,000 g. METHODS: cross-section cohort study with 411 consecutive cases of fetal macrosomia (FM which occurred from March 1998 to March 2005. Data were compared to 7,349 cases of fetal birthweight >2,500 and <3,999 g which occurred in the same period. Maternal variables (maternal age, parity, diabetes, previous cesarean section, meconium-stained amniotic fluid, cephalopelvic disproportion, main cesarean section indications and perinatal variables (birth injury, <7 1-min and 5-min Apgar score, fetal and early neonatal mortality range, need of neonatal intensive care unit were analyzed. For statistical analysis the chi2 test with Yates correction and Student's t test were used with the level of significance set at 5%. RESULTS: FM was significantly associated with older mothers, more parous and <7 1-min Apgar score (p<0.05; OR=1.8; 95% CI: 1,4-2.5 and <7 5-min Apgar score (p<0,05; OR=2.3; 95% CI: 1

  8. Metabolism of lipoproteins by human fetal hepatocytes

    International Nuclear Information System (INIS)

    Carr, B.R.

    1987-01-01

    The rate of clearance of lipoproteins from plasma appears to play a role in the development of atherogenesis. The liver may account for as much as two thirds of the removal of low-density lipoprotein and one third of the clearance of high-density lipoprotein in certain animal species and humans, mainly by receptor-mediated pathways. The purpose of the present investigation was to determine if human fetal hepatocytes maintained in vitro take up and degrade lipoproteins. We first determined that the maximal binding capacity of iodine 125-iodo-LDL was approximately 300 ng of low-density lipoprotein protein/mg of membrane protein and an apparent dissociation constant of approximately 60 micrograms low-density lipoprotein protein/ml in membranes prepared from human fetal liver. We found that the maximal uptake of [ 125 I]iodo-LDL and [ 125 I]iodo-HDL by fetal hepatocytes occurred after 12 hours of incubation. Low-density lipoprotein uptake preceded the appearance of degradation products by 4 hours, and thereafter the degradation of low-density lipoprotein increased linearly for at least 24 hours. In contrast, high-density lipoprotein was not degraded to any extent by fetal hepatocytes. [ 125 I]Iodo-LDL uptake and degradation were inhibited more than 75% by preincubation with low-density lipoprotein but not significantly by high-density lipoprotein, whereas [ 125 I]iodo-HDL uptake was inhibited 70% by preincubation with high-density lipoprotein but not by low-density lipoprotein. In summary, human fetal hepatocytes take up and degrade low-density lipoprotein by a receptor-mediated process similar to that described for human extrahepatic tissues

  9. Ethical analysis of non-medical fetal ultrasound.

    Science.gov (United States)

    Leung, John Lai Yin; Pang, Samantha Mei Che

    2009-09-01

    Obstetric ultrasound is the well-recognized prenatal test used to visualize and determine the condition of a pregnant woman and her fetus. Apart from the clinical application, some businesses have started promoting the use of fetal ultrasound machines for nonmedical reasons. Non-medical fetal ultrasound (also known as 'keepsake' ultrasound) is defined as using ultrasound to view, take a picture, or determine the sex of a fetus without a medical indication. Notwithstanding the guidelines and warnings regarding ultrasound safety issued by governments and professional bodies, the absence of scientifically proven physical harm to fetuses from this procedure seems to provide these businesses with grounds for rapid expansion. However, this argument is too simplistic because current epidemiological evidence is not synchronous with advancing ultrasound technology. As non-medical fetal ultrasound has aroused very significant public attention, a thorough ethical analysis of this topic is essential. Using a multifaceted approach, we analyse the ethical perspective of non-medical fetal ultrasound in terms of the expectant mother, the fetus and health professionals. After applying four major theories of ethics and principles (the precautionary principle; theories of consequentialism and impartiality; duty-based theory; and rights-based theories), we conclude that obstetric ultrasound practice is ethically justifiable only if the indication for its use is based on medical evidence. Non-medical fetal ultrasound can be considered ethically unjustifiable. Nevertheless, the ethical analysis of this issue is time dependent owing to rapid advancements in ultrasound technology and the safety issue. The role of health professionals in ensuring that obstetric ultrasound is an ethically justifiable practice is also discussed.

  10. Muerte fetal

    OpenAIRE

    Andrés Pons, G.; Eduardo Sepúlveda, S.; Juan Luis Leiva, B.; Gustavo Rencoret, P.; Alfredo Germain, A.

    2014-01-01

    La muerte fetal es un evento poco frecuente pero de gran repercusión afectiva para los padres involucrados y su entorno. En el presente artículo revisaremos la epidemiología, las causas, orientaremos a los médicos en los pasos a seguir para realizar adecuadamente el estudio, la resolución del embarazo y el manejo del embarazo siguiente junto con las estrategias para prevenirlo.

  11. Fetal organ dosimetry for the Techa River and Ozyorsk Offspring Cohorts. Pt. 2. Radionuclide S values for fetal self-dose and maternal cross-dose

    International Nuclear Information System (INIS)

    Maynard, Matthew R.; Bolch, Wesley E.; Shagina, Natalia B.; Tolstykh, Evgenia I.; Degteva, Marina O.; Fell, Tim P.

    2015-01-01

    One of the many objectives of the European Union's SOLO (Epidemiological Studies of Exposed Southern Urals Populations) project is to quantify the radiation dose-response following chronic in utero exposures to ionizing radiation. The project is presently conducting a pooled analysis of two cohorts of individuals born to exposed mothers - the Techa River Offspring Cohort (TROC) and the Ozyorsk Offspring Cohort (OOC). The TROC includes the offspring of mothers with external exposures to contaminated riverbanks and internal ingestions of 89 Sr, 90 Sr/ 90 Y, and 137 Cs/ 137m Ba, while the OOC includes the offspring of mothers with external exposures seen within the Mayak plutonium production facilities and internal inhalation of 239 Pu and possibly 131 I. In the present study, a newly created Urals-based series of fetal and maternal models is employed to assess S values for all seven radionuclides. Among all fetal ages, S values ranged in magnitude from 10 -14 to 10 -10 Gy per Bq-s for fetal source organs and from 10 -18 to 10 -14 Gy per Bq-s from maternal source organs, depending upon particle type, particle energy, and fetal age. For a given radionuclide and fetal age, S values for fetal source organs were approximately two orders of magnitude higher than for maternal source organs. Little variation in S values was observed among fetal source organs, while variations of over 100 % with respect to the mean were observed for maternal source organs near the fetus. S value variations from maternal cross-fire were highly dependent on fetal position and separation distance from the maternal source organ. These radionuclide S values have been coupled with biokinetic models for use in cohort dose assessment within the SOLO project. (orig.)

  12. Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

    Science.gov (United States)

    Turan, S; Turan, O M; Ty-Torredes, K; Harman, C R; Baschat, A A

    2009-06-01

    The challenges of the first-trimester examination of the fetal heart may in part be overcome by technical advances in three-dimensional (3D) ultrasound techniques. Our aim was to standardize the first-trimester 3D imaging approach to the cardiac examination to provide the most consistent and accurate display of anatomy. Low-risk women with normal findings on first-trimester screening at 11 to 13 + 6 weeks had cardiac ultrasound using the following sequence: (1) identification of the four-chamber view; (2) four-dimensional (4D) volume acquisition with spatiotemporal image correlation (STIC) and color Doppler imaging (angle = 20 degrees, sweep 10 s); (3) offline, tomographic ultrasound imaging (TUI) analysis with standardized starting plane (four-chamber view), slice number and thickness; (4) assessment of fetal cardiac anatomy (four-chamber view, cardiac axis, size and symmetry, atrioventricular valves, great arteries and descending aorta) with and without color Doppler. 107 consecutive women (age, 16-42 years, body mass index 17.2-50.2 kg/m(2)) were studied. A minimum of three 3D volumes were obtained for each patient, transabdominally in 91.6%. Fetal motion artifact required acquisition of more than three volumes in 20%. The median time for TUI offline analysis was 100 (range, 60-240) s. Individual anatomic landmarks were identified in 89.7-99.1%. Visualization of all structures in one panel was observed in 91 patients (85%). Starting from a simple two-dimensional cardiac landmark-the four-chamber view-the standardized STIC-TUI technique enables detailed segmental cardiac evaluation of the normal fetal heart in the first trimester. (c) 2009 ISUOG.

  13. PCR/LDR/capillary electrophoresis for detection of single-nucleotide differences between fetal and maternal DNA in maternal plasma.

    Science.gov (United States)

    Yi, Ping; Chen, Zhuqin; Zhao, Yan; Guo, Jianxin; Fu, Huabin; Zhou, Yuanguo; Yu, Lili; Li, Li

    2009-03-01

    The discovery of fetal DNA in maternal plasma has opened up an approach for noninvasive diagnosis. We have now assessed the possibility of detecting single-nucleotide differences between fetal and maternal DNA in maternal plasma by polymerase chain reaction (PCR)/ligase detection reaction((LDR)/capillary electrophoresis. PCR/LDR/capillary electrophoresis was applied to detect the genotype of c.454-397T>gene (ESR1) from experimental DNA models of maternal plasma at different sensitivity levels and 13 maternal plasma samples.alphaC in estrogen receptor. (1) Our results demonstrated that the technique could discriminate low abundance single-nucleotide mutation with a mutant/normal allele ratio up to 1:10 000. (2) Examination of ESR1 c.454-397T>C genotypes by using the method of restriction fragment length analysis was performed in 25 pregnant women, of whom 13 pregnant women had homozygous genotypes. The c.454-397T>C genotypes of paternally inherited fetal DNA in maternal plasma of these 13 women were detected by PCR/LDR/capillary electrophoresis, which were accordant with the results of umbilical cord blood. PCR/LDR/capillary electrophoresis has very high sensitivity to distinguish low abundance single nucleotide differences and can discriminate point mutations and single-nucleotide polymorphisms(SNPs) of paternally inherited fetal DNA in maternal plasma.

  14. Fetal absorbed doses by radiopharmaceutical administration

    International Nuclear Information System (INIS)

    Rojo, Ana M; Gomez Parada, Ines M.; Di Trano, Jose L.

    2000-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author)

  15. Glucocorticoids and fetal programming part 1: Outcomes.

    Science.gov (United States)

    Moisiadis, Vasilis G; Matthews, Stephen G

    2014-07-01

    Fetal development is a critical period for shaping the lifelong health of an individual. However, the fetus is susceptible to internal and external stimuli that can lead to adverse long-term health consequences. Glucocorticoids are an important developmental switch, driving changes in gene regulation that are necessary for normal growth and maturation. The fetal hypothalamic-pituitary-adrenal (HPA) axis is particularly susceptible to long-term programming by glucocorticoids; these effects can persist throughout the life of an organism. Dysfunction of the HPA axis as a result of fetal programming has been associated with impaired brain growth, altered behaviour and increased susceptibility to chronic disease (such as metabolic and cardiovascular disease). Moreover, the effects of glucocorticoid-mediated programming are evident in subsequent generations, and transmission of these changes can occur through both maternal and paternal lineages.

  16. Liquid-Diet with Alcohol Alters Maternal, Fetal and Placental Weights and the Expression of Molecules Involved in Integrin Signaling in the Fetal Cerebral Cortex

    Directory of Open Access Journals (Sweden)

    Ujjwal K. Rout

    2010-11-01

    Full Text Available Maternal alcohol consumption during pregnancy causes wide range of behavioral and structural deficits in children, commonly known as Fetal Alcohol Syndrome (FAS. Children with FAS may suffer behavioral deficits in the absence of obvious malformations. In rodents, the exposure to alcohol during gestation changes brain structures and weights of offspring. The mechanism of FAS is not completely understood. In the present study, an established rat (Long-Evans model of FAS was used. The litter size and the weights of mothers, fetuses and placentas were examined on gestation days 18 or 20. On gestation day 18, the effects of chronic alcohol on the expression levels of integrin receptor subunits, phospholipase-Cγ and N-cadherin were examined in the fetal cerebral cortices. Presence of alcohol in the liquid-diet reduced the consumption and decreased weights of mothers and fetuses but increased the placental weights. Expression levels of β1 and α3 integrin subunits and phospholipase-Cγ2 were significantly altered in the fetal cerebral cortices of mothers on alcohol containing diet. Results show that alcohol consumption during pregnancy even with protein, mineral and vitamin enriched diet may affect maternal and fetal health, and alter integrin receptor signaling pathways in the fetal cerebral cortex disturbing the development of fetal brains.

  17. True Umbilical Cord Knot Leading to Fetal Demise

    African Journals Online (AJOL)

    weight was 140 kg, height 1.69 m, blood pressure 120 mmHg. The booking ... The fetal heart tones were monitored using Doppler sonicaid. They remained normal throughout .... true knot, seemingly because the umbilical cord vessels can be compressed ... Therefore, the Wharton's jelly surrounding the fetal vessels has the ...

  18. Development of a preparation and staining method for fetal erythroblasts in maternal blood : Simultaneous immunocytochemical staining and FISH analysis

    NARCIS (Netherlands)

    Oosterwijk, JC; Mesker, WE; Ouwerkerk-van Velzen, MCM; Knepfle, CFHM; Wiesmeijer, KC; van den Burg, MJM; Beverstock, GC; Bernini, LF; van Ommen, Gert-Jan B; Kanhai, HHH; Tanke, HJ

    1998-01-01

    In order to detect fetal nucleated red blood cells (NRBCs) in maternal blood, a protocol was developed which aimed at producing a reliable staining method for combined immunocytochemical and FISH analysis. The technique had to be suitable for eventual automated screening of slides. Chorionic villi

  19. A case of fetal intestinal volvulus without malrotation causing severe anemia.

    Science.gov (United States)

    Nakagawa, Tomoko; Tachibana, Daisuke; Kitada, Kohei; Kurihara, Yasushi; Terada, Hiroyuki; Koyama, Masayasu; Sakae, Yukari; Morotomi, Yoshiki; Nomura, Shiho; Saito, Mika

    2015-01-01

    Fetal intestinal volvulus without malrotation is a rare, life-threatening disease. Left untreated, hemorrhage from necrotic bowel tissue will lead to severe fetal anemia and even intrauterine death. We encountered a case of fetal intestinal volvulus causing severe anemia, which was diagnosed postnatally and successfully treated with surgical intervention.

  20. Paternal genetic contribution influences fetal vulnerability to maternal alcohol consumption in a rat model of fetal alcohol spectrum disorder.

    Directory of Open Access Journals (Sweden)

    Laura J Sittig

    2010-04-01

    Full Text Available Fetal alcohol exposure causes in the offspring a collection of permanent physiological and neuropsychological deficits collectively termed Fetal Alcohol Spectrum Disorder (FASD. The timing and amount of exposure cannot fully explain the substantial variability among affected individuals, pointing to genetic influences that mediate fetal vulnerability. However, the aspects of vulnerability that depend on the mother, the father, or both, are not known.Using the outbred Sprague-Dawley (SD and inbred Brown Norway (BN rat strains as well as their reciprocal crosses, we administered ethanol (E, pair-fed (PF, or control (C diets to the pregnant dams. The dams' plasma levels of free thyroxine (fT4, triiodothyronine (T3, free T3 (fT3, and thyroid stimulating hormone (TSH were measured to elucidate potential differences in maternal thyroid hormonal environment, which affects specific aspects of FASD. We then compared alcohol-exposed, pair fed, and control offspring of each fetal strain on gestational day 21 (G21 to identify maternal and paternal genetic effects on bodyweight and placental weight of male and female fetuses.SD and BN dams exhibited different baseline hypothalamic-pituitary-thyroid function. Moreover, the thyroid function of SD dams was more severely affected by alcohol consumption while that of BN dams was relatively resistant. This novel finding suggests that genetic differences in maternal thyroid function are one source of maternal genetic effects on fetal vulnerability to FASD. The fetal vulnerability to decreased bodyweight after alcohol exposure depended on the genetic contribution of both parents, not only maternal contribution as previously thought. In contrast, the effect of maternal alcohol consumption on placental weight was consistent and not strain-dependent. Interestingly, placental weight in fetuses with different paternal genetic contributions exhibited opposite responses to caloric restriction (pair feeding. In summary

  1. Fetal Alcohol Syndrome.

    Science.gov (United States)

    Zerrer, Peggy

    The paper reviews Fetal Alcohol Syndrome (FAS), a series of effects seen in children whose mothers drink alcohol to excess during pregnancy. The identification of FAS and its recognition as a major health problem in need of prevention are traced. Characteristics of children with FAS are described and resultant growth retardation, abnormal physical…

  2. Epidemiologia do óbito fetal em população de baixa renda Epidemiology of fetal death in a low income population

    Directory of Open Access Journals (Sweden)

    Márcia M. A. de Aquino

    1998-03-01

    Full Text Available A morte fetal não é uma entidade rara e, em países em desenvolvimento, suas causas mais prevalentes continuam sendo passíveis de controle e/ou tratamento. O objetivo deste estudo foi investigar causas de morte fetal em uma população brasileira. Foi um estudo descritivo realizado no Hospital Maternidade Leonor Mendes de Barros, em São Paulo. Foram estudadas 122 gestantes com diagnóstico de óbito fetal e idade gestacional de vinte semanas ou mais. Os procedimentos estatísticos utilizados foram média e desvio-padrão. As principais causas de morte identificadas foram hipertensão arterial e infecções e em um quarto dos casos a causa não foi determinada. Concluiu-se que uma proporção importante de óbitos era prevenível e que houve taxa significativa de causas não-identificadas. Os resultados deste estudo poderão ser úteis para orientação de programas de prevenção primária, principalmente quanto à assistência pré-natal.Fetal death may not be considered an unusual event and, in developing countries, the most prevalent causes could be possibly controlled and/or treated. The purpose of the present study was to investigate causes of fetal death in a Brazilian population. This is a descriptive study performed at the Hospital Maternidade Leonor Mendes de Barros in São Paulo. The study subjects were 122 pregnant women with diagnosis of fetal death and gestation age of 20 or more weeks. The statistical procedures used were means and standard deviation. The main causes of the fetal death were hypertensive disorders and infections and, for a quarter of the cases, they were not identified at all. It is concluded that an important percentage of fetal deaths would have been prevented and that there was a significant number of unidentified causes. Results of the present study might be useful to orientate a primary prevention health program, specially concerning antenatal care.

  3. ST analysis of the fetal ECG : towards evidence based fetal surveillance

    NARCIS (Netherlands)

    Becker, J.H.

    2012-01-01

    It was the aim of this thesis to perform a meta-analysis of published trial on FECG monitoring during labor, to assess its effects on fetal outcome, on the use of FBS, and on instrumental and operative interventions. Furthermore we conducted secondary studies of published data sets to address thus

  4. 3H-cyclosporine internalization and secretion by human fetal pancreatic islets

    International Nuclear Information System (INIS)

    Formby, B.; Walker, L.; Peterson, C.M.

    1988-01-01

    Human fetal pancreatic islets were isolated from 16- to 20-week-old fetuses by a collagenase technique and cultured 48 hr in RPMI 1640 containing 10% human adult serum and unlabeled 0 to 5 micrograms cyclosporine A (CsA)/ml. Insulin secretory capacity of human fetal islets was expressed as a fractional stimulatory ratio FSR = F2/F1 of the fractional secretion rates during two successive 1 hr static incubations first with 2 mM glucose (F1) to stabilize secretion followed by maximal stimulus, i.e., 25 mM glucose plus 10 mM L-leucine and 10 mM L-arginine (F2). Unlabeled CsA at the above concentrations had no significant effects on the insulin secretory capacity expressed by FSR-values. Studies of net uptake of 3H-CsA by islets cultured for varying periods up to 40 hr and expressed as picomole 3H-CsA per picomole islet insulin content demonstrated that uptake rate was slow and did not reach isotopic equilibrium over the 40 hr of culture. When isolated fetal islets were cultured for 48 hr in the presence of 3H-CsA and varying concentrations of unlabeled CsA it was found during two successive 1 hr static incubations that fetal islets secrete insulin concomitantly with 3H-CsA following maximal stimulus for secretion. An optimal secretory molar ratio of 3H-CsA to insulin of 4.0 +/- 1.3 (n = 7) was found after islets were cultured 48 hr in the presence of a saturating 2.128 micrograms 3H-CsA per milliliter culture medium. In three successive 30-min static incubations of 3H-CsA loaded islets, first with low glucose, followed by high glucose plus L-arginine and L-leucine, and finally with high glucose plus L-arginine and L-leucine and 10 mM theophylline, the proportional fractional secretion rates of insulin and 3H-CsA were of the same magnitude

  5. Ultrasonographic and clinical features of fetal cholelithiasis. Three case reports

    International Nuclear Information System (INIS)

    Agnifili, Alessio; Gola, Piersante; Marino, Maria; Verzaro, Roberto; Carducci, Giuseppe; Mancini, Ermanno; Rizzo, Franz Maria; Carducci, Augusto; Biasini, Giancarlo

    1997-01-01

    Fetal cholelithiasis was first diagnosed in 1983 and since then there have been only few reports about the presence of gallstones in the fetus. Maternal conditions, fetal or obstetrical predisposing risk factors have been proposed to have a causative role, by the pathogenesis of fetal gallstones remains unknown. Clinical sequelae of fetal gallstones are poorly understood as well as the role of fetal cholelithiasis in predisposing the adult to gallstones. They report on 3 patients whose cholelithiasis was diagnosed by obstetrical ultrasonography. Repeated ultrasound scans were performed in each patient until resolution of the US images. The goal of US was to correctly identify the number, size and US features of the material within the gallbladder. The presence of distal shadowing or comet-tail artifact was assess. Multiple, small echogenic foci without distal shadowing were recognized in the fetal gallbladder in their patients. In the third case echogenic foci disappeared during pregnancy. In all the cases, US showed no biliary tract abnormality, and neither the mothers nor the patients had clinical or laboratory findings consistent with liver or biliary diseases. The authors discuss a diagnostic protocol to detect and follow-up gallstones in the perinatal period by ultrasonography. In their experience, fetal cholelithiasis confirmed to be a self-limiting disease without complications and did not require any form of therapy. However a close follow-up is indicated in these patients until spontaneous resolution is demonstrated by US

  6. "Taking its toll": the challenges of working in fetal medicine.

    Science.gov (United States)

    Menezes, Melody A; Hodgson, Jan M; Sahhar, Margaret; Metcalfe, Sylvia A

    2013-03-01

    Advances in genetic technologies have resulted in the diagnosis during pregnancy of increasing numbers of fetal abnormalities. A few published personal commentaries have indicated that health professionals' interactions with couples at risk of a fetal abnormality can be emotionally and ethically challenging, highlighting the need for empirical research in this area. This study sought to explore whether working in the fetal medicine setting has an effect on health professionals and to ascertain any supports used to manage these effects. In-depth interviews were conducted with 40 medical and allied health professionals working in fetal medicine settings in Melbourne, Australia. Qualitative analysis of the interview data was performed using thematic analysis. Participants discussed at length the emotional impact of working with patients who were experiencing adverse pregnancy outcomes. All participants reported that working in fetal medicine had an impact on their daily lives, and many spoke about dreaming about or losing sleep over patient outcomes. Participants described working in this setting as being particularly difficult when they were pregnant themselves. Most spoke about feeling largely unsupported in their work and felt that these effects resulted in burnout and staff turnover. This study explored several work force concerns in fetal medicine. Health professionals working with couples at risk of a fetal abnormality are vulnerable to the phenomena of compassion fatigue and burnout. The need for formal support and self-care management is suggested. © 2013, Copyright the Authors Journal compilation © 2013, Wiley Periodicals, Inc.

  7. Síndrome de transfusión feto-fetal: experiencia de 69 casos

    OpenAIRE

    Yamamoto C, Masami; Huamán, Moisés; Astudillo D, Julio; Pedraza S, Daniel; Fleiderman D, José; Hidalgo, Guillermo; Insunza F, Alvaro; González V, Marcelo

    2016-01-01

    La fetoscopia por síndrome de transfusión feto fetal es la cirugía fetal más realizada en el mundo. Los resultados deben ser reportados, para que las pacientes puedan elegir su opción de atención. Objetivo: Determinar los resultados de cirugía fetal en el síndrome de transfusión feto-fetal. Diseño: Estudio retrospectivo. Lugar: Clínica Alemana, Santiago, Chile. Participantes: Gestantes con gemelares. Intervenciones: La cirugía fetal se realizó con anestesia local, endoscopios Storz de 3,3 mm,...

  8. Fetal brain disruption sequence versus fetal brain arrest: A distinct autosomal recessive developmental brain malformation phenotype.

    Science.gov (United States)

    Abdel-Salam, Ghada M H; Abdel-Hamid, Mohamed S; El-Khayat, Hamed A; Eid, Ola M; Saba, Soliman; Farag, Mona K; Saleem, Sahar N; Gaber, Khaled R

    2015-05-01

    The term fetal brain disruption sequence (FBDS) was coined to describe a number of sporadic conditions caused by numerous external disruptive events presenting with variable imaging findings. However, rare familial occurrences have been reported. We describe five patients (two sib pairs and one sporadic) with congenital severe microcephaly, seizures, and profound intellectual disability. Brain magnetic resonance imaging (MRI) revealed unique and uniform picture of underdeveloped cerebral hemispheres with increased extraxial CSF, abnormal gyral pattern (polymicrogyria-like lesions in two sibs and lissencephaly in the others), loss of white matter, dysplastic ventricles, hypogenesis of corpus callosum, and hypoplasia of the brainstem, but hypoplastic cerebellum in one. Fetal magnetic resonance imaging (FMRI) of two patients showed the same developmental brain malformations in utero. These imaging findings are in accordance with arrested brain development rather than disruption. Molecular analysis excluded mutations in potentially related genes such as NDE1, MKL2, OCLN, and JAM3. These unique clinical and imaging findings were described before among familial reports with FBDS. However, our patients represent a recognizable phenotype of developmental brain malformations, that is, apparently distinguishable from either familial microhydranencephaly or microlissencephaly that were collectively termed FBDS. Thus, the use of the umbrella term FBDS is no longer helpful. Accordingly, we propose the term fetal brain arrest to distinguish them from other familial patients diagnosed as FBDS. The presence of five affected patients from three unrelated consanguineous families suggests an autosomal-recessive mode of inheritance. The spectrum of fetal brain disruption sequence is reviewed. © 2015 Wiley Periodicals, Inc.

  9. Impact of Oxidative Stress in Fetal Programming

    OpenAIRE

    Thompson, Loren P.; Al-Hasan, Yazan

    2012-01-01

    Intrauterine stress induces increased risk of adult disease through fetal programming mechanisms. Oxidative stress can be generated by several conditions, such as, prenatal hypoxia, maternal under- and overnutrition, and excessive glucocorticoid exposure. The role of oxidant molecules as signaling factors in fetal programming via epigenetic mechanisms is discussed. By linking oxidative stress with dysregulation of specific target genes, we may be able to develop therapeutic strategies that pr...

  10. Fetal QRS detection and heart rate estimation: a wavelet-based approach

    International Nuclear Information System (INIS)

    Almeida, Rute; Rocha, Ana Paula; Gonçalves, Hernâni; Bernardes, João

    2014-01-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR. (paper)

  11. Diagnosis, treatment and long-term outcome in fetal hydrocephalus

    International Nuclear Information System (INIS)

    Yamasaki, Mami; Nonaka, Masahiro; Bamba, Yohei; Teramoto, Chika; Ban, Chiaki; Pooh, Ritsuko

    2011-01-01

    The objective of this study was to evaluate the method of prenatally estimating an appropriate clinical outcome in fetal hydrocephalus. Retrospective study, single institute (Osaka National Hospital). Hundred and seventeen cases with fetal hydrocephalus treated at Osaka National Hospital from 1992 to 2010 were analysed. Of the 117 cases analysed, 38% are diagnosed as isolated ventriculomegaly (IVM), 51% as other types of malformation (30 cases of myelomeningocele, 4 cases of holoprosencephaly, 4 of Dandy Walker syndrome, 10 of arachnoid cyst and 6 of encephalocele etc.) and 11% as secondary hydrocephalus. They are diagnosed between 17 and 40 weeks of gestation (average 27 weeks), 17% diagnosed between 17 and 21 weeks, 30% between 22 and 27 weeks and 53% after 28 weeks. With the exception of 9 aborted cases and 30 unknown cases too young to be evaluated or lost due to lack of follow-up, final outcome was analyzed in 78 cases. Of these 78 cases, 15% died in utero or after birth, 23% showed severe retardation, 17% moderate retardation, 26% mild retardation, and 19% showed good outcome. Long term consequences were mostly influenced by basic disease and accompanied anomalies. Hydrocephalus associated with arachnoid cyst, atresia of Monro, corpus callosum agenesis and hydrocephalus due to fetal intracranial hemorrhage are categorized in the good outcome group. On the other hand, holoprosencephaly, hydrocephalus associated with encephalocele, syndromic hydrocephalus and hydrocephalus due to fetal virus infection are categorized in the poor outcome group. In order to accurate diagnosis and proper counseling, establishment of diagnosis protocol and treatment policy for fetal hydrocephalus including not only fetal sonography, fetal MRI, toxoplasma, rubella, cytomegalovirus, herpes simplex (TORCH) screening test but also chromosomal and gene testing is required. (author)

  12. Fetal Biometry in the Population of Southern Punjab, Pakistan

    International Nuclear Information System (INIS)

    Sabih, D.E.; Rahim, M.K.

    2017-01-01

    Background: Ultrasound estimation of fetal parameters is one of the most important examinations. Hadlock and other foreign fetal biometry curves are used in Pakistan as there are no national normative data derived from local population. Objectives: To construct local reference charts and equations for fetal biometric measurements and amniotic fluid index (AFI) using a large sample of fetuses examined at 14 - 40 weeks in the population of southern Punjab. Study design, settings and duration: The prospective, cross sectional study conducted at the Multan Institute of Nuclear Medicine and Radiotherapy (MINAR) over a one year period from December 2010 to November 2011. Subjects and Methods: A total of 566 randomly selected pregnant females, who fulfilled the inclusion criteria were included in the study after informed consent. Each woman was scanned once only, between 14 and 40 weeks of gestation, and her fetal measurements were also recorded simultaneously. Regression models were used to estimate the mean and standard deviation at each week of gestation. Fetal biometric parameters of local population were compared with those of Hadlock and Singaporean Asian population. Results were statistically analyzed and also presented graphically across the different gestational ages to allow visual comparison. Results: Biometric measurements were obtained for 566 fetuses. There was no significant difference between fetal parameters of local population and those of Hadlock. When compared with those of the Singaporean Asian population, femur length and head circumference were larger while biparietal diameter was smaller in our population. Conclusion: We have constructed local reference centiles for fetal measurements and equations for dating of pregnancy for Southern Punjab. The biometric measurements are slightly different from Singaporean Asian population, but there was no statistically significant difference between these measurements and those by Hadlock. (author)

  13. A deep learning approach for fetal QRS complex detection.

    Science.gov (United States)

    Zhong, Wei; Liao, Lijuan; Guo, Xuemei; Wang, Guoli

    2018-04-20

    Non-invasive foetal electrocardiography (NI-FECG) has the potential to provide more additional clinical information for detecting and diagnosing fetal diseases. We propose and demonstrate a deep learning approach for fetal QRS complex detection from raw NI-FECG signals by using a convolutional neural network (CNN) model. The main objective is to investigate whether reliable fetal QRS complex detection performance can still be obtained from features of single-channel NI-FECG signals, without canceling maternal ECG (MECG) signals. A deep learning method is proposed for recognizing fetal QRS complexes. Firstly, we collect data from set-a of the PhysioNet/computing in Cardiology Challenge database. The sample entropy method is used for signal quality assessment. Part of the bad quality signals is excluded in the further analysis. Secondly, in the proposed method, the features of raw NI-FECG signals are normalized before they are fed to a CNN classifier to perform fetal QRS complex detection. We use precision, recall, F-measure and accuracy as the evaluation metrics to assess the performance of fetal QRS complex detection. The proposed deep learning method can achieve relatively high precision (75.33%), recall (80.54%), and F-measure scores (77.85%) compared with three other well-known pattern classification methods, namely KNN, naive Bayes and SVM. the proposed deep learning method can attain reliable fetal QRS complex detection performance from the raw NI-FECG signals without canceling MECG signals. In addition, the influence of different activation functions and signal quality assessment on classification performance are evaluated, and results show that Relu outperforms the Sigmoid and Tanh on this particular task, and better classification performance is obtained with the signal quality assessment step in this study.

  14. Defining and predicting 'intrauterine fetal renal failure' in congenital lower urinary tract obstruction.

    Science.gov (United States)

    Ruano, Rodrigo; Safdar, Adnan; Au, Jason; Koh, Chester J; Gargollo, Patricio; Shamshirsaz, Alireza A; Espinoza, Jimmy; Cass, Darrell L; Olutoye, Oluyinka O; Olutoye, Olutoyin A; Welty, Stephen; Roth, David R; Belfort, Michael A; Braun, Michael C

    2016-04-01

    The aim of this study was to identify predictors of 'intrauterine fetal renal failure' in fetuses with severe congenital lower urinary tract obstruction (LUTO). We undertook a retrospective study of 31 consecutive fetuses with a diagnosis of LUTO in a tertiary Fetal Center between April 2013 and April 2015. Predictors of 'intrauterine fetal renal failure' were evaluated in those infants with severe LUTO who had either a primary composite outcome measure of neonatal death in the first 24 h of life due to severe pulmonary hypoplasia or a need for renal replacement therapy within 7 days of life. The following variables were analyzed: fetal bladder re-expansion 48 h after vesicocentesis, fetal renal ultrasound characteristics, fetal urinary indices, and amniotic fluid volume. Of the 31 fetuses included in the study, eight met the criteria for 'intrauterine fetal renal failure'. All of the latter had composite poor postnatal outcomes based on death within 24 h of life (n = 6) or need for dialysis within 1 week of life (n = 2). The percentage of fetal bladder refilling after vesicocentesis at time of initial evaluation was the only predictor of 'intrauterine fetal renal failure' (cut-off <27 %, area under the time-concentration curve 0.86, 95 % confidence interval 0.68-0.99; p = 0.009). We propose the concept of 'intrauterine fetal renal failure' in fetuses with the most severe forms of LUTO. Fetal bladder refilling can be used to reliably predict 'intrauterine fetal renal failure', which is associated with severe pulmonary hypoplasia or the need for dialysis within a few days of life.

  15. Prenatal diagnosis and treatment perspective of fetal hypothyroidism with goiter

    International Nuclear Information System (INIS)

    Gulraze, A.; Kurdi, W.; Tulbah, M.; Niaz, F.A.

    2013-01-01

    We describe two cases of fetal goiter in women with no history of thyroid disease. Diagnosis of fetal goiter during antenatal care was made by ultrasound and MRI. Congenital hypothyroidism was confirmed by fetal blood sampling that was treated with weekly intra-amniotic injections of L-thyroxin. One fetus was initially treated with four weekly intra-amniotic injections of 200 mu gms of L-thyroxin, later increased to 400 mu gms. The other fetus was treated with only three weekly intraamniotic injections of 400 mu gms of L-thyroxin. Therapeutic response was monitored by repeated ultrasound and MRI along with fetal blood sampling. At birth, none of the babies had goiter and were put on oral thyroxin. Post-natal studies were suggestive of congenital hypothyroidism due to dyshormogenesis. No abnormality was detected at follow-up. These cases highlight the role of intra-amniotic thyroxine in management of fetal hypothyroidism with goiter. (author)

  16. Low-complexity R-peak detection for ambulatory fetal monitoring

    NARCIS (Netherlands)

    Rooijakkers, M.J.; Rabotti, C.; Oei, S.G.; Mischi, M.

    2012-01-01

    Non-invasive fetal health monitoring during pregnancy is becoming increasingly important because of the increasing number of high-risk pregnancies. Despite recent advances in signal-processing technology, which have enabled fetal monitoring during pregnancy using abdominal electrocardiogram (ECG)

  17. An efficient sequence for fetal brain imaging at 3T with enhanced T1 contrast and motion robustness.

    Science.gov (United States)

    Ferrazzi, Giulio; Price, Anthony N; Teixeira, Rui Pedro A G; Cordero-Grande, Lucilio; Hutter, Jana; Gomes, Ana; Padormo, Francesco; Hughes, Emer; Schneider, Torben; Rutherford, Mary; Kuklisova Murgasova, Maria; Hajnal, Joseph V

    2018-07-01

    Ultrafast single-shot T 2 -weighted images are common practice in fetal MR exams. However, there is limited experience with fetal T 1 -weighted acquisitions. This study aims at establishing a robust framework that allows fetal T 1 -weighted scans to be routinely acquired in utero at 3T. A 2D gradient echo sequence with an adiabatic inversion was optimized to be robust to fetal motion and maternal breathing optimizing grey/white matter contrast at the same time. This was combined with slice to volume registration and super resolution methods to produce volumetric reconstructions. The sequence was tested on 22 fetuses. Optimized grey/white matter contrast and robustness to fetal motion and maternal breathing were achieved. Signal from cerebrospinal fluid (CSF) and amniotic fluid was nulled and 0.75 mm isotropic anatomical reconstructions of the fetal brain were obtained using slice-to-volume registration and super resolution techniques. Total acquisition time for a single stack was 56 s, all acquired during free breathing. Enhanced sensitivity to normal anatomy and pathology with respect to established methods is demonstrated. A direct comparison with a 3D spoiled gradient echo sequence and a controlled motion experiment run on an adult volunteer are also shown. This paper describes a robust framework to perform T 1 -weighted acquisitions and reconstructions of the fetal brain in utero. Magn Reson Med 80:137-146, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic

  18. Prenatal Diagnosis of Fetal Encephalomalacia after Maternal Diabetic Ketoacidosis

    Science.gov (United States)

    Love, Rozalyn; Lee, Amy; Matiasek, April; Carter, William; Ylagan, Marissa

    2014-01-01

    Introduction Encephalomalacia in a developing fetus is a rare and devastating neurological finding on radiologic imaging. Maternal diabetic ketoacidosis (DKA) can lead to metabolic and vascular derangements which can cause fetal encephalomalacia. Case We report the case of a 27-year-old pregnant woman with White's Class C diabetes mellitus who presented in the 25th week of gestation with DKA. Four weeks after her discharge, marked fetal cerebral ventriculomegaly was noted on ultrasound. A subsequent fetal magnetic resonance imaging (MRI) demonstrated extensive, symmetric cystic encephalomalacia, primarily involving both cerebral hemispheres. The pregnancy was continued with close fetal and maternal surveillance. The patient underwent a repeat cesarean delivery in her 37th week. The infant had a 1 month neonatal intensive care unit stay with care rendered by a multiple disciplinary team of pediatric subspecialists. The postnatal course was complicated by global hypotonia, poor feeding, delayed development and ultimately required anticonvulsants for recurrent seizures. He died at the age of 9 months from aspiration during a seizure. Discussion Although the maternal mortality from DKA has declined, DKA still confers significant neurological fetal morbidity to its survivors. PMID:25452892

  19. Prenatal Diagnosis of Fetal Encephalomalacia after Maternal Diabetic Ketoacidosis

    Directory of Open Access Journals (Sweden)

    Rozalyn Love

    2014-11-01

    Full Text Available Introduction - Encephalomalacia in a developing fetus is a rare and devastating neurological finding on radiologic imaging. Maternal diabetic ketoacidosis (DKA can lead to metabolic and vascular derangements which can cause fetal encephalomalacia. Case - We report the case of a 27-year-old pregnant woman with White's Class C diabetes mellitus who presented in the 25th week of gestation with DKA. Four weeks after her discharge, marked fetal cerebral ventriculomegaly was noted on ultrasound. A subsequent fetal magnetic resonance imaging (MRI demonstrated extensive, symmetric cystic encephalomalacia, primarily involving both cerebral hemispheres. The pregnancy was continued with close fetal and maternal surveillance. The patient underwent a repeat cesarean delivery in her 37th week. The infant had a 1 month neonatal intensive care unit stay with care rendered by a multiple disciplinary team of pediatric subspecialists. The postnatal course was complicated by global hypotonia, poor feeding, delayed development and ultimately required anticonvulsants for recurrent seizures. He died at the age of 9 months from aspiration during a seizure. Discussion - Although the maternal mortality from DKA has declined, DKA still confers significant neurological fetal morbidity to its survivors.

  20. Prenatal diagnosis of fetal encephalomalacia after maternal diabetic ketoacidosis.

    Science.gov (United States)

    Love, Rozalyn; Lee, Amy; Matiasek, April; Carter, William; Ylagan, Marissa

    2014-11-01

    Introduction Encephalomalacia in a developing fetus is a rare and devastating neurological finding on radiologic imaging. Maternal diabetic ketoacidosis (DKA) can lead to metabolic and vascular derangements which can cause fetal encephalomalacia. Case We report the case of a 27-year-old pregnant woman with White's Class C diabetes mellitus who presented in the 25th week of gestation with DKA. Four weeks after her discharge, marked fetal cerebral ventriculomegaly was noted on ultrasound. A subsequent fetal magnetic resonance imaging (MRI) demonstrated extensive, symmetric cystic encephalomalacia, primarily involving both cerebral hemispheres. The pregnancy was continued with close fetal and maternal surveillance. The patient underwent a repeat cesarean delivery in her 37th week. The infant had a 1 month neonatal intensive care unit stay with care rendered by a multiple disciplinary team of pediatric subspecialists. The postnatal course was complicated by global hypotonia, poor feeding, delayed development and ultimately required anticonvulsants for recurrent seizures. He died at the age of 9 months from aspiration during a seizure. Discussion Although the maternal mortality from DKA has declined, DKA still confers significant neurological fetal morbidity to its survivors.

  1. Muerte fetal

    Directory of Open Access Journals (Sweden)

    G. Andrés Pons, DR

    2014-11-01

    Full Text Available La muerte fetal es un evento poco frecuente pero de gran repercusión afectiva para los padres involucrados y su entorno. En el presente artículo revisaremos la epidemiología, las causas, orientaremos a los médicos en los pasos a seguir para realizar adecuadamente el estudio, la resolución del embarazo y el manejo del embarazo siguiente junto con las estrategias para prevenirlo.

  2. Contribution of maternal thyroxine to fetal thyroxine pools in normal rats near term

    International Nuclear Information System (INIS)

    Morreale de Escobar, G.; Calvo, R.; Obregon, M.J.; Escobar Del Rey, F.

    1990-01-01

    Normal dams were equilibrated isotopically with [ 125 I]T4 infused from 11 to 21 days of gestation, at which time maternal and fetal extrathyroidal tissues were obtained to determine their [ 125 I]T4 and T4 contents. The specific activity of the [ 125 I]T4 in the fetal tissues was lower than in maternal T4 pools. The extent of this change allows evaluation of the net contribution of maternal T4 to the fetal extrathyroidal T4 pools. At 21 days of gestation, near term, this represents 17.5 +/- 0.9% of the T4 in fetal tissues, a value considerably higher than previously calculated. The methodological approach was validated in dams given a goitrogen to block fetal thyroid function. The specific activities of the [ 125 I]T4 in maternal and fetal T4 pools were then similar, confirming that in cases of fetal thyroid impairment the T4 in fetal tissues is determined by the maternal contribution. Thus, previous statements that in normal conditions fetal thyroid economy near term is totally independent of maternal thyroid status ought to be reconsidered

  3. Design of a light stimulator for fetal and neonatal magnetoencephalography

    International Nuclear Information System (INIS)

    Wilson, J D; Adams, A J; Murphy, P; Eswaran, H; Preissl, H

    2009-01-01

    The design, safety analysis and performance of a fetal visual stimulation system suitable for fetal and neonatal magnetoencephalography studies are presented. The issue of fetal, neonatal and maternal safety is considered and the maximum permissible exposure is computed for the maternal skin and the adult eye. The risk for neonatal eye exposure is examined. It is demonstrated that the fetus, neonate and mother are not at risk. (note)

  4. SLC9B1 methylation predicts fetal intolerance of labor.

    Science.gov (United States)

    Knight, Anna K; Conneely, Karen N; Kilaru, Varun; Cobb, Dawayland; Payne, Jennifer L; Meilman, Samantha; Corwin, Elizabeth J; Kaminsky, Zachary A; Dunlop, Anne L; Smith, Alicia K

    2018-01-01

    Fetal intolerance of labor is a common indication for delivery by Caesarean section. Diagnosis is based on the presence of category III fetal heart rate tracing, which is an abnormal heart tracing associated with increased likelihood of fetal hypoxia and metabolic acidemia. This study analyzed data from 177 unique women who, during their prenatal visits (7-15 weeks and/or 24-32 weeks) to Atlanta area prenatal care clinics, consented to provide blood samples for DNA methylation (HumanMethylation450 BeadChip) and gene expression (Human HT-12 v4 Expression BeadChip) analyses. We focused on 57 women aged 18-36 (mean 25.4), who had DNA methylation data available from their second prenatal visit. DNA methylation patterns at CpG sites across the genome were interrogated for associations with fetal intolerance of labor. Four CpG sites (P value intolerance of labor. DNA methylation and gene expression were negatively associated when examined longitudinally during pregnancy using a linear mixed-effects model. Positive predictive values of methylation of these four sites ranged from 0.80 to 0.89, while negative predictive values ranged from 0.91 to 0.92. The four CpG sites were also associated with fetal intolerance of labor in an independent cohort (the Johns Hopkins Prospective PPD cohort). Therefore, fetal intolerance of labor could be accurately predicted from maternal blood samples obtained between 24-32 weeks gestation. Fetal intolerance of labor may be accurately predicted from maternal blood samples obtained between 24-32 weeks gestation by assessing DNA methylation patterns of SLC9B1. The identification of pregnant women at elevated risk for fetal intolerance of labor may allow for the development of targeted treatments or management plans.

  5. Prenatal ultrasound findings of fetal neoplasms

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Cho, Jeong Yeon; Song, Mi Jin; Min, Jee Yeon; Han, Byoung Hee; Lee, Young Ho; Cho, Byung Jae; Kim, Seung Hyup

    2002-01-01

    A variety of neoplasms can develop in each tetal organ. Most fetal neoplasms can be detected by careful prenatal ultrasonographic examination. Some neoplosms show specific ultrasonographic findings suggesting the differential diagnosis, but others do not. Knowledge of the presence of a neoplasm in the fetus may alter the prenatal management of a pregnancy and the mode of delivery, and facilitates immediate postnatal treatment. During the last five years, we experienced 32 cases of fetal neoplasms in a variety of organs. We describe their typical and ultrasonographic findings with correlating postnatal CT, MRI, and pathologic findings

  6. Pontomedullary disconnection: fetal and neonatal considerations

    Energy Technology Data Exchange (ETDEWEB)

    McCann, Emma; Sweeney, Elizabeth [Royal Liverpool Children' s Hospital, Department of Clinical Genetics, Liverpool (United Kingdom); Pilling, David [Royal Liverpool Children' s Hospital, Department of Paediatric Radiology, Liverpool (United Kingdom); Hesseling, Markus; Subhedar, Nim [Liverpool Women' s Hospital, Department of Neonatology, Liverpool (United Kingdom); Roberts, Devender [Liverpool Women' s Hospital, Department of Fetal Medicine, Liverpool (United Kingdom)

    2005-08-01

    The cerebellar and pontocerebellar hypoplasias present a unique challenge when detected in the developing fetus. A diverse aetiology and prognosis make counselling of these families difficult. Advances in fetal imaging allow for more accurate diagnosis and counselling, but postnatal MRI is still required. A case is presented in which cerebellar hypoplasia was detected at 20 weeks gestation. Later fetal imaging provided further information, but a diagnosis of pontomedullary disconnection was not made until the postnatal MRI scan. The clinical findings and possible causes of such pontocerebellar abnormalities are discussed. (orig.)

  7. Pontomedullary disconnection: fetal and neonatal considerations

    International Nuclear Information System (INIS)

    McCann, Emma; Sweeney, Elizabeth; Pilling, David; Hesseling, Markus; Subhedar, Nim; Roberts, Devender

    2005-01-01

    The cerebellar and pontocerebellar hypoplasias present a unique challenge when detected in the developing fetus. A diverse aetiology and prognosis make counselling of these families difficult. Advances in fetal imaging allow for more accurate diagnosis and counselling, but postnatal MRI is still required. A case is presented in which cerebellar hypoplasia was detected at 20 weeks gestation. Later fetal imaging provided further information, but a diagnosis of pontomedullary disconnection was not made until the postnatal MRI scan. The clinical findings and possible causes of such pontocerebellar abnormalities are discussed. (orig.)

  8. Fetal primary small bowel volvulus in a child without intestinal malrotation.

    Science.gov (United States)

    Chung, Jae Hee; Lim, Gye-Yeon; We, Ji Sun

    2013-07-01

    Fetal primary small bowel volvulus without atresia or malrotation is an extremely rare but life-threatening surgical emergency. We report a case of primary small bowel volvulus that presented as sudden fetal distress and was diagnosed on the basis of the 'whirl-pool sign' of fetal sonography. This diagnosis led to emergency operation after birth at the third trimester with a good outcome. Although the pathogenesis of fetal primary small bowel volvulus is unclear, ganglion cell immaturity may play a role in the etiology. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Maternal hair testing for the assessment of fetal exposure to drug of abuse during early pregnancy: Comparison with testing in placental and fetal remains.

    Science.gov (United States)

    Falcon, M; Pichini, S; Joya, J; Pujadas, M; Sanchez, A; Vall, O; García Algar, O; Luna, A; de la Torre, R; Rotolo, M C; Pellegrini, M

    2012-05-10

    Drug use by pregnant women in the first trimester of pregnancy and subsequent fetal exposure during early gestation can be assessed only by repetitive/systematic maternal blood/urine analysis or segmental hair analysis. No evidence of any relationship between maternal/fetal exposure during this specific period of gestation has been demonstrated to date in a human model. To clarify drugs toxicokinetics and transplacental passage during early pregnancy, the presence of the most widely used recreational drugs of abuse and metabolites was investigated in the proximal 4cm hair segments of women undergoing voluntary termination of pregnancy (n=280) during the 12th week of gestation and the results were compared to those from placenta and fetal tissue samples in order to verify whether maternal hair testing can reflect fetal exposure and, if so, to what extent. Hair, placenta and fetal remains were analyzed by validated gas chromatography mass spectrometry assays. Eighty one positive hair samples were identified: 60 were positive for cannabis (74.1%), 28 for cocaine (34.6%), 7 for opiates (8.6%), 3 for MDMA (3.7%) and 18.5% were positive for more than one drug. The positive hair test results were confirmed in placenta/fetal tissues in 10 cases out of 60 for cannabis (16. 7%); in 7 out of 28 for cocaine (25%); and none for the 6 opiates positive cases and 3 MDMA cases, respectively. Drugs/metabolites in hair of pregnant women can be used as biomarkers of past drug use (repetitive or sporadic), although the use is not always reflected in fetal/placental tissues. There are several possible hypotheses to explain the results: (1) the use occurred before the start of pregnancy, (2) past sporadic consumption which could be measured in hair but not in fetal and placental remains because of the narrow window of drug detection in placental/fetal tissues; (3) the sensitivity of the analytical methods was not high enough for the detection of the minute amount of drugs of abuse and

  10. Intrauterine Defensive Mechanism of Amniotic Fluid and Fetal Membranes

    OpenAIRE

    金山, 尚裕

    1994-01-01

    To determine the intrauterine defensive role of urinary trypsin inhibitor (UTI), we studied the effects of UTI in amniotic fluid, fetal membranes and myometrium. The level of UTI was 94±34U/ml in neonatal urine (compared to adult urine 8.0±6.0U/ml) and 88±37U/ml in amniotic fluid. This may indicate that the main source of UTI in the amniotic fluid is the fetal urine. UTI was found to be concentrated in vernix, fetal intestine, amniotic membranes and uterine myometrium. Immunostaining of term ...

  11. Malnutrition during fetal life, fetal programming and implications for farm aninals productivity

    DEFF Research Database (Denmark)

    Nielsen, Mette Olaf; Khanal, Prabhat; Johnsen, Lærke

    Some 20 years ago, observations from human epidemiological research revolutionized the scientific view of the importance of fetal life development for body functions in postnatal life. Until then, it was believed that the genome received from the parents at conception in mammals would define the ...

  12. Fetal growth, cognitive function, and brain volumes in childhood and adolescence.

    Science.gov (United States)

    Rogne, Tormod; Engstrøm, Andreas Aass; Jacobsen, Geir Wenberg; Skranes, Jon; Østgård, Heidi Furre; Martinussen, Marit

    2015-03-01

    To evaluate the association between fetal growth pattern and cognitive function at 5 and 9 years and regional brain volumes at 15 years. Eighty-three term-born small-for-gestational-age (SGA) neonates and 105 non-SGA neonates in a control group were available for follow-up. Based on serial fetal ultrasound measurements from gestational weeks 25-37, SGA neonates were classified with fetal growth restriction (n=13) or non-fetal growth restriction (n=36). Cognitive function was assessed at 5 and 9 years, and brain volumes were estimated with cerebral magnetic resonance imaging at 15 years. Small-for-gestational-age children had lower performance intelligence quotient at 5 years compared with those in a control group (107.3 compared with 112.5, Pgrowth restriction and control groups, the SGA fetal growth restriction group had significantly lower performance intelligence quotient at 5 years (103.5 compared with 112.5, Pgrowth restriction and control groups for thalamic (17.4 compared with 18.6 cm, Pintelligence quotient scores at 5 and 9 years and smaller brain volumes at 15 years compared with those in the control group, but these findings were only found in those with fetal growth restriction, indicating a possible relationship to decelerated fetal growth. II.

  13. A Case of Fetal Intestinal Volvulus without Malrotation Causing Severe Anemia

    Directory of Open Access Journals (Sweden)

    Tomoko Nakagawa

    2015-01-01

    Full Text Available Fetal intestinal volvulus without malrotation is a rare, life-threatening disease. Left untreated, hemorrhage from necrotic bowel tissue will lead to severe fetal anemia and even intrauterine death. We encountered a case of fetal intestinal volvulus causing severe anemia, which was diagnosed postnatally and successfully treated with surgical intervention.

  14. Application of real-time PCR of sex-independent insertion-deletion polymorphisms to determine fetal sex using cell-free fetal DNA from maternal plasma.

    Science.gov (United States)

    Ho, Sherry Sze Yee; Barrett, Angela; Thadani, Henna; Asibal, Cecille Laureano; Koay, Evelyn Siew-Chuan; Choolani, Mahesh

    2015-07-01

    Prenatal diagnosis of sex-linked disorders requires invasive procedures, carrying a risk of miscarriage of up to 1%. Cell-free fetal DNA (cffDNA) present in cell-free DNA (cfDNA) from maternal plasma offers a non-invasive source of fetal genetic material for analysis. Detection of Y-chromosome sequences in cfDNA indicates presence of a male fetus; in the absence of a Y-chromosome signal a female fetus is inferred. We aimed to validate the clinical utility of insertion-deletion polymorphisms (INDELs) to confirm presence of a female fetus using cffDNA. Quantitative real-time PCR (qPCR) for the Y-chromosome-specific sequence, SRY, was performed on cfDNA from 82 samples at 6-39 gestational weeks. In samples without detectable SRY, qPCRs for eight INDELs were performed on maternal genomic DNA and cfDNA. Detection of paternally inherited fetal alleles in cfDNA negative for SRY confirmed a female fetus. Fetal sex was correctly determined in 77/82 (93.9%) cfDNA samples. SRY was detected in all 39 samples from male-bearing pregnancies, and none of the 43 female-bearing pregnancies (sensitivity and specificity of SRY qPCR is therefore 100%; 95% CI 91%-100%). Paternally inherited fetal alleles were detected in 38/43 samples with no SRY signal, confirming the presence of a female fetus (INDEL assay sensitivity is therefore 88.4%; 95% CI 74.1%-95.6%). Since paternally inherited fetal INDELs were not used in women bearing male fetuses, the specificity of INDELs cannot be calculated. Five cfDNA samples were negative for both SRY and INDELS. We have validated a non-invasive prenatal test to confirm fetal sex as early as 6 gestational weeks using cffDNA from maternal plasma.

  15. Radiation absorbed dose to the human fetal thyroid

    International Nuclear Information System (INIS)

    Watson, E.E.

    1992-01-01

    The embryo/fetus is recognized to be particularly susceptible to damage from exposure to radiation. Many advisory groups have studied available information concerning radiation doses and radiation effects with the goal of reducing the risk to the embryo/fetus. Of particular interest are radioactive isotopes of iodine. Radioiodine taken into the body of a pregnant woman presents a possible hazard for the embryo/fetus. The fetal thyroid begins to concentrate iodine at about 13 weeks after conception and continues to do so throughout gestation. At term, the organic iodine concentration in the fetal blood is about 75% of that in the mother's blood. This paper presents a review the models that have been proposed for the calculation of the dose to the fetal thyroid from radioisotopes of iodine taken into the body of the pregnant woman as sodium iodide. A somewhat different model has been proposed, and estimates of the radiation dose to the fetal thyroid calculated from this model are given for each month of pregnancy from 123 I , 124 I , 125 I , and 131 I

  16. Association of fetal cranial shape with shoulder dystocia.

    Science.gov (United States)

    Belfort, M A; White, G L; Vermeulen, F M

    2012-03-01

    To evaluate whether fetal cranial shape is related to shoulder dystocia. We compared shoulder dystocia cases (n = 18) with controls (normal vaginal deliveries, n = 18) in a retrospective matched-pairs observational study. Subjects were matched for known maternal and fetal risk factors and then evaluated for fetal biometric differences, which were measured by ultrasound near delivery. We tested multivariable risk models to predict shoulder dystocia by logistic regression. Cases had a smaller estimated occipitofrontal diameter (OFD) (P = 0.02) and a larger biparietal diameter/estimated OFD ratio (P = 0.003). A multivariable model including estimated fetal weight, estimated OFD, maternal weight and diabetes mellitus had sensitivity and specificity of 86% and 95%, respectively, and positive and negative likelihood ratios of 18.9 and 0.15, respectively. Estimated OFD significantly increased the predictive value of the model. A small estimated OFD is a risk factor for shoulder dystocia in the presence of other significant risk factors. A multivariable model including estimated OFD can predict shoulder dystocia in a clinically useful range. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  17. STORY AND HISTORY IN FETAL BEHAVIOR RESEARCH.

    Science.gov (United States)

    Brakke, Karen

    2015-09-01

    In their monograph, DiPietro, Costigan, and Voegtline present an important and thoughtful portrait of low-risk fetal development during the last trimester of gestation, and they also pay tribute to the Fels Longitudinal Study investigators' early work in this area. In this commentary, the history and legacy of the Fels Institute is further explored within the broader context of fetal research, and DiPietro et al.'s findings are placed in alignment with contemporary dynamic systems' theoretical approaches that emphasize longitudinal analysis of emergent behavior and process during early development. The commentary puts forth the assertion that the work reported by DiPietro and her colleagues tells a story that sets the stage for a new generation of technology-enhanced and culturally expanded investigations of fetal behavior. © 2015 The Society for Research in Child Development, Inc.

  18. GLI3 Links Environmental Arsenic Exposure and Human Fetal Growth

    Directory of Open Access Journals (Sweden)

    Emily F. Winterbottom

    2015-06-01

    Full Text Available Although considerable evidence suggests that in utero arsenic exposure affects children's health, these data are mainly from areas of the world where groundwater arsenic levels far exceed the World Health Organization limit of 10 μg/L. We, and others, have found that more common levels of in utero arsenic exposure may also impact children's health. However, the underlying molecular mechanisms are poorly understood. To address this issue, we analyzed the expression of key developmental genes in fetal placenta in a birth cohort of women using unregulated water supplies in a US region with elevated groundwater arsenic. We identified several genes whose expression associated with maternal arsenic exposure in a fetal sex-specific manner. In particular, expression of the HEDGEHOG pathway component, GLI3, in female placentae was both negatively associated with arsenic exposure and positively associated with infant birth weight. This suggests that modulation of GLI3 in the fetal placenta, and perhaps in other fetal tissues, contributes to arsenic's detrimental effects on fetal growth. We showed previously that arsenic-exposed NIH3T3 cells have reduced GLI3 repressor protein. Together, these studies identify GLI3 as a key signaling node that is affected by arsenic, mediating a subset of its effects on developmental signaling and fetal health.

  19. Prenatal diagnosis of fetal skeletal dysplasia with 3D CT

    International Nuclear Information System (INIS)

    Miyazaki, Osamu; Horiuchi, Tetsuya; Nishimura, Gen; Sago, Haruhiko; Hayashi, Satoshi; Kosaki, Rika

    2012-01-01

    Clinical use of 3D CT for fetal skeletal malformations is controversial. The purpose of this study was to evaluate the efficacy of fetal 3D CT using three protocols with different radiation doses and through comparing findings between fetal CT and conventional postnatal radiographic skeletal survey. Seventeen fetuses underwent CT for suspected skeletal dysplasia. A relay of three CT protocols with stepwise dose-reduction were used over the study period. The concordance between the CT diagnosis and the final diagnosis was assessed. Ninety-three radiological findings identifiable on radiographs were compared with CT. Fetal CT provided the correct diagnosis in all 17 fetuses, the detectability rate of cardinal findings was 93.5 %. In 59 % of the fetuses an US-based diagnosis was changed prenatally due to CT findings. The estimated fetal radiation dose in the final protocol was 3.4 mSv (50 %) of the initial protocol, and this dose reduction did not result in degraded image quality. The capability of fetal CT to delineate the skeleton was almost the same as that of postnatal skeletal survey. The perinatal management was altered due to these more specific CT findings, which aided in counseling and in the management of the pregnancy. (orig.)

  20. Prenatal diagnosis of fetal skeletal dysplasia with 3D CT

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Osamu; Horiuchi, Tetsuya [National Center for Child Health and Development, Department of Radiology, Seatagaya-ku, Tokyo (Japan); Nishimura, Gen [Tokyo Metropolitan Children' s Medical Center, Department of Pediatric Imaging, Fuchu-shi, Tokyo (Japan); Sago, Haruhiko; Hayashi, Satoshi [National Center for Child Health and Development, Department of Perinatal Medicine and Maternal Care, Seatagaya-ku, Tokyo (Japan); Kosaki, Rika [National Center for Child Health and Development, Department of Strategic Medicine, Division of Clinical Genetics and Molecular Medicine, Seatagaya-ku, Tokyo (Japan)

    2012-07-15

    Clinical use of 3D CT for fetal skeletal malformations is controversial. The purpose of this study was to evaluate the efficacy of fetal 3D CT using three protocols with different radiation doses and through comparing findings between fetal CT and conventional postnatal radiographic skeletal survey. Seventeen fetuses underwent CT for suspected skeletal dysplasia. A relay of three CT protocols with stepwise dose-reduction were used over the study period. The concordance between the CT diagnosis and the final diagnosis was assessed. Ninety-three radiological findings identifiable on radiographs were compared with CT. Fetal CT provided the correct diagnosis in all 17 fetuses, the detectability rate of cardinal findings was 93.5 %. In 59 % of the fetuses an US-based diagnosis was changed prenatally due to CT findings. The estimated fetal radiation dose in the final protocol was 3.4 mSv (50 %) of the initial protocol, and this dose reduction did not result in degraded image quality. The capability of fetal CT to delineate the skeleton was almost the same as that of postnatal skeletal survey. The perinatal management was altered due to these more specific CT findings, which aided in counseling and in the management of the pregnancy. (orig.)

  1. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    Science.gov (United States)

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  2. File list: ALL.Neu.50.AllAg.Fetal_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.50.AllAg.Fetal_brain hg19 All antigens Neural Fetal brain SRX142786,SRX2096...60880 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Neu.50.AllAg.Fetal_brain.bed ...

  3. File list: ALL.Neu.05.AllAg.Fetal_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.05.AllAg.Fetal_brain hg19 All antigens Neural Fetal brain SRX056802,SRX1427...60882 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Neu.05.AllAg.Fetal_brain.bed ...

  4. File list: ALL.Neu.20.AllAg.Fetal_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ALL.Neu.20.AllAg.Fetal_brain hg19 All antigens Neural Fetal brain SRX142786,SRX2096...60882 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/ALL.Neu.20.AllAg.Fetal_brain.bed ...

  5. Fetal programming in meat production.

    Science.gov (United States)

    Du, Min; Wang, Bo; Fu, Xing; Yang, Qiyuan; Zhu, Mei-Jun

    2015-11-01

    Nutrient fluctuations during the fetal stage affects fetal development, which has long-term impacts on the production efficiency and quality of meat. During the early development, a pool of mesenchymal progenitor cells proliferate and then diverge into either myogenic or adipogenic/fibrogenic lineages. Myogenic progenitor cells further develop into muscle fibers and satellite cells, while adipogenic/fibrogenic lineage cells develop into adipocytes, fibroblasts and resident fibro-adipogenic progenitor cells. Enhancing the proliferation and myogenic commitment of progenitor cells during fetal development enhances muscle growth and lean production in offspring. On the other hand, promoting the adipogenic differentiation of adipogenic/fibrogenic progenitor cells inside the muscle increases intramuscular adipocytes and reduces connective tissue, which improves meat marbling and tenderness. Available studies in mammalian livestock, including cattle, sheep and pigs, clearly show the link between maternal nutrition and the quantity and quality of meat production. Similarly, chicken muscle fibers develop before hatching and, thus, egg and yolk sizes and hatching temperature affect long-term growth performance and meat production of chicken. On the contrary, because fishes are able to generate new muscle fibers lifelong, the impact of early nutrition on fish growth performance is expected to be minor, which requires further studies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. File list: DNS.Neu.50.AllAg.Fetal_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.50.AllAg.Fetal_brain hg19 DNase-seq Neural Fetal brain SRX040380,SRX040395,...6,SRX121278 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.Neu.50.AllAg.Fetal_brain.bed ...

  7. File list: DNS.Neu.20.AllAg.Fetal_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.20.AllAg.Fetal_brain hg19 DNase-seq Neural Fetal brain SRX040380,SRX040395,...6,SRX121278 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.Neu.20.AllAg.Fetal_brain.bed ...

  8. File list: DNS.Neu.10.AllAg.Fetal_brain [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available DNS.Neu.10.AllAg.Fetal_brain hg19 DNase-seq Neural Fetal brain SRX040380,SRX040395,...6,SRX121278 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/DNS.Neu.10.AllAg.Fetal_brain.bed ...

  9. High Fat Diet Exposure during Fetal Life Enhances Plasma and Hepatic Omega-6 Fatty Acid Profiles in Fetal Wistar Rats

    Directory of Open Access Journals (Sweden)

    Marlon E. Cerf

    2015-08-01

    Full Text Available Pregnant rats were fed a high fat diet (HFD for the first (HF1, second (HF2, third (HF3 or all three weeks (HFG of gestation. Maintenance on a HFD during specific periods of gestation was hypothesized to alter fetal glycemia, insulinemia, induce insulin resistance; and alter fetal plasma and hepatic fatty acid (FA profiles. At day 20 of gestation, fetal plasma and hepatic FA profiles were determined by gas chromatography; body weight, fasting glycemia, insulinemia and the Homeostasis Model Assessment (HOMA-insulin resistance were also determined. HF3 fetuses were heaviest concomitant with elevated glycemia and insulin resistance (p < 0.05. HFG fetuses had elevated plasma linoleic (18:2 n-6 and arachidonic (20:4 n-6 acid proportions (p < 0.05. In the liver, HF3 fetuses displayed elevated linoleic, eicosatrienoic (20:3 n-6 and arachidonic acid proportions (p < 0.05. HFG fetuses had reduced hepatic docosatrienoic acid (22:5 n-3 proportions (p < 0.05. High fat maintenance during the final week of fetal life enhances hepatic omega-6 FA profiles in fetuses concomitant with hyperglycemia and insulin resistance thereby presenting a metabolically compromised phenotype.

  10. Assessment and control of fetal exposure

    International Nuclear Information System (INIS)

    Harty, R.; Swinth, K.L.; Traub, R.J.

    1991-10-01

    The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, measuring and calculating the dose to the embryo/fetus, and recording the pertinent information. Alternative strategies for handling these factors while ensuring maximum protection of the embryo/fetus and the rights and responsibilities of employees and employers are discussed

  11. Fetal programming of schizophrenia: select mechanisms.

    Science.gov (United States)

    Debnath, Monojit; Venkatasubramanian, Ganesan; Berk, Michael

    2015-02-01

    Mounting evidence indicates that schizophrenia is associated with adverse intrauterine experiences. An adverse or suboptimal fetal environment can cause irreversible changes in brain that can subsequently exert long-lasting effects through resetting a diverse array of biological systems including endocrine, immune and nervous. It is evident from animal and imaging studies that subtle variations in the intrauterine environment can cause recognizable differences in brain structure and cognitive functions in the offspring. A wide variety of environmental factors may play a role in precipitating the emergent developmental dysregulation and the consequent evolution of psychiatric traits in early adulthood by inducing inflammatory, oxidative and nitrosative stress (IO&NS) pathways, mitochondrial dysfunction, apoptosis, and epigenetic dysregulation. However, the precise mechanisms behind such relationships and the specificity of the risk factors for schizophrenia remain exploratory. Considering the paucity of knowledge on fetal programming of schizophrenia, it is timely to consolidate the recent advances in the field and put forward an integrated overview of the mechanisms associated with fetal origin of schizophrenia. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Time-scale analysis of antepartum fetal heart rate variability

    NARCIS (Netherlands)

    Peters, C.H.L.

    2011-01-01

    Reliable evaluation of fetal condition and early detection of fetal distress is one of the largest challenges in modern obstetrics. Safely protected within the maternal womb, the fetus is rather inaccessible for physiological measurements. One of few physiological phenomena that can be measured

  13. Fetal Origins of Mental Health: The Developmental Origins of Health and Disease Hypothesis.

    Science.gov (United States)

    O'Donnell, Kieran J; Meaney, Michael J

    2017-04-01

    The quality of fetal growth and development predicts the risk for a range of noncommunicable, chronic illnesses. These observations form the basis of the "developmental origins of health and disease" hypothesis, which suggests that the intrauterine signals that compromise fetal growth also act to "program" tissue differentiation in a manner that predisposes to later illness. Fetal growth also predicts the risk for later psychopathology. These findings parallel studies showing that antenatal maternal emotional well-being likewise predicts the risk for later psychopathology. Taken together, these findings form the basis for integrative models of fetal neurodevelopment, which propose that antenatal maternal adversity operates through the biological pathways associated with fetal growth to program neurodevelopment. The authors review the literature and find little support for such integrated models. Maternal anxiety, depression, and stress all influence neurodevelopment but show modest, weak, or no associations with known stress mediators (e.g., glucocorticoids) or with fetal growth. Rather, compromised fetal development appears to establish a "meta-plastic" state that increases sensitivity to postnatal influences. There also remain serious concerns that observational studies associating either fetal growth or maternal mental health with neurodevelopmental outcomes fail to account for underlying genetic factors. Finally, while the observed relation between fetal growth and adult health has garnered considerable attention, the clinical relevance of these associations remains to be determined. There are both considerable promise and important challenges for future studies of the fetal origins of mental health.

  14. Placental fetal stem segmentation in a sequence of histology images

    Science.gov (United States)

    Athavale, Prashant; Vese, Luminita A.

    2012-02-01

    Recent research in perinatal pathology argues that analyzing properties of the placenta may reveal important information on how certain diseases progress. One important property is the structure of the placental fetal stems. Analysis of the fetal stems in a placenta could be useful in the study and diagnosis of some diseases like autism. To study the fetal stem structure effectively, we need to automatically and accurately track fetal stems through a sequence of digitized hematoxylin and eosin (H&E) stained histology slides. There are many problems in successfully achieving this goal. A few of the problems are: large size of images, misalignment of the consecutive H&E slides, unpredictable inaccuracies of manual tracing, very complicated texture patterns of various tissue types without clear characteristics, just to name a few. In this paper we propose a novel algorithm to achieve automatic tracing of the fetal stem in a sequence of H&E images, based on an inaccurate manual segmentation of a fetal stem in one of the images. This algorithm combines global affine registration, local non-affine registration and a novel 'dynamic' version of the active contours model without edges. We first use global affine image registration of all the images based on displacement, scaling and rotation. This gives us approximate location of the corresponding fetal stem in the image that needs to be traced. We then use the affine registration algorithm "locally" near this location. At this point, we use a fast non-affine registration based on L2-similarity measure and diffusion regularization to get a better location of the fetal stem. Finally, we have to take into account inaccuracies in the initial tracing. This is achieved through a novel dynamic version of the active contours model without edges where the coefficients of the fitting terms are computed iteratively to ensure that we obtain a unique stem in the segmentation. The segmentation thus obtained can then be used as an

  15. Fetal Sirenomelia Associated with an Abdominal Cyst Originating from a Saccular Cloaca.

    Science.gov (United States)

    Kinjo, Yui; Masamoto, Hitoshi; Nitta, Hayase; Kinjo, Tadatsugu; Tamaki, Tomoko; Yoshimi, Naoki; Aoki, Yoichi

    2018-01-01

    A 40-year-old pregnant woman presented with a fetal abdominal cyst and oligohydramnios. Color Doppler scan revealed a single blood vessel from the fetal aorta into a single umbilical artery. Severe oligohydramnios limited ultrasonographic evaluation of the fetal lower limbs, kidneys, or bladder. The pregnancy was terminated; the fetus showed fused lower limbs, bulging abdomen, and absent external genitalia and was diagnosed with type III sirenomelia. On autopsy, no normal bladder was observed, but duodenal atresia, anorectal atresia, and right renal agenesis were found. An intra-abdominal cyst, diagnosed histologically as a saccular cloaca, occupied the abdominal cavity. Ultrasonographic diagnosis of fetal sirenomelia is difficult due to poor depiction of the lower limbs. A vitelline artery leading to a single umbilical artery and a fetal abdominal cyst occupying most of the abdominal cavity are considered fetal sirenomelia associated with large defects of the gastrointestinal and genitourinary tracts.

  16. Fetal Sirenomelia Associated with an Abdominal Cyst Originating from a Saccular Cloaca

    Directory of Open Access Journals (Sweden)

    Yui Kinjo

    2018-01-01

    Full Text Available A 40-year-old pregnant woman presented with a fetal abdominal cyst and oligohydramnios. Color Doppler scan revealed a single blood vessel from the fetal aorta into a single umbilical artery. Severe oligohydramnios limited ultrasonographic evaluation of the fetal lower limbs, kidneys, or bladder. The pregnancy was terminated; the fetus showed fused lower limbs, bulging abdomen, and absent external genitalia and was diagnosed with type III sirenomelia. On autopsy, no normal bladder was observed, but duodenal atresia, anorectal atresia, and right renal agenesis were found. An intra-abdominal cyst, diagnosed histologically as a saccular cloaca, occupied the abdominal cavity. Ultrasonographic diagnosis of fetal sirenomelia is difficult due to poor depiction of the lower limbs. A vitelline artery leading to a single umbilical artery and a fetal abdominal cyst occupying most of the abdominal cavity are considered fetal sirenomelia associated with large defects of the gastrointestinal and genitourinary tracts.

  17. Traumatic Fetal Intracranial Hemorrhage Suggested by Point-of-Care Ultrasound

    Directory of Open Access Journals (Sweden)

    Lei Wu

    2018-01-01

    Full Text Available While the use of ultrasound to diagnose a fetal intracranial hemorrhage in utero is not a new concept, the emphasis of point-of-care ultrasound (POCUS at the initial trauma presentation of the mother to evaluate for fetal injury is novel. A review of the literature failed to reveal a single case report wherein POCUS in the workup of a pregnant trauma patient led to the diagnosis of fetal intracranial hemorrhage. This is such a case.

  18. Fetal irradiation of the fetus patient during periradicular therapy

    International Nuclear Information System (INIS)

    Salat, D.; Klepanec, A.

    2018-01-01

    In this presentation, female fetal irradiation in periradicular therapy (PRT) is described. Although such CT examinations are not acute, there are cases where pregnant women are also exposed, as is shown in this case study. Fetal dose calculation was performed using the Monte Carlo simulation contained in the DQC system, designed to automatically monitor patient radiation at the CT workplace. Also, the process of optimization of radiation protection has not been sufficiently implemented in the CT workplace. Consistent with the basic principles of radiation protection would avoid unnecessary risks high fetal doses in PRT examinations. (authors)

  19. Fetal cerebral biometry: normal parenchymal findings and ventricular size

    International Nuclear Information System (INIS)

    Garel, C.

    2005-01-01

    Assessing fetal cerebral biometry is one means of ascertaining that the development of the fetal central nervous system is normal. Norms have been established on large cohorts of fetuses by sonographic and neurofetopathological studies. Biometric standards have been established in MR in much smaller cohorts. The purpose of this paper is to analyse methods of measuring a few parameters in MR [biparietal diameter (BPD), fronto-occipital diameter (FOD), length of the corpus callosum (LCC), atrial diameter, transverse cerebellar diameter, height, anteroposterior diameter and surface of the vermis] and to compare US and MR in the assessment of fetal cerebral biometry. (orig.)

  20. Fetal Exposure to Environmental Neurotoxins in Taiwan

    OpenAIRE

    Jiang, Chuen-Bin; Hsi, Hsing-Cheng; Fan, Chun-Hua; Chien, Ling-Chu

    2014-01-01

    Mercury (Hg), lead (Pb), cadmium (Cd), and arsenic (As) are recognized neurotoxins in children that particularly affect neurodevelopment and intellectual performance. Based on the hypothesis that the fetal basis of adult disease is fetal toxic exposure that results in adverse outcomes in adulthood, we explored the concentrations of key neurotoxins (i.e., Hg, Pb, Cd, and As) in meconium to identify the risk factors associated with these concentrations. From January 2007 to December 2009, 545 m...