  1. Proposal on new formulas for renal depth in the technetium-99m-mercaptoacetyltriglycine (MAG3) scintigraphy

    International Nuclear Information System (INIS)

    Uchiyama, Katsuhiro; Kuniyasu, Yoshio; Niio, Yasuo

    1997-01-01

    Recently, camera-based techniques to measure effective renal plasma flow (ERPF) have become more popular than single plasma sample techniques because camera-based measurements avoid the necessity of delayed plasma samples and in vitro techniques. The measurements of ERPF are used to estimate the clearance of technetium-99m-mercaptoacetyltriglycine (MAG3). However, camera-based techniques are dependent on an accurate estimate of renal depth to correct for soft-tissue attenuation. Then, new formulas for renal depth correction of technetium-99m-MAG3 clearance in place of Toennesen's, M. Ito's, K. Itoh's, and Taylor's methods were tried to establish in this paper. Eleven hundred and seventy patients without any renal disease were objected. The data from measurement of renal depth using X-ray CT in supine position were analyzed statistically. The depths of right kidney (Dr) and left kidney (Dl) were 7.33±1.27 and 7.07±1.27 cm. The correlation coefficients between Dr and height (H), body weight (W), body Surface area (BSA: W 0.425 xH 0.725 x0.007184 m 2 ), age, and abdominal thickness (Ta) were 0.275, 0.709, 0.615, 0.087, and 0.743. The correlation coefficients between Dl and H, W, BSA, age, and Ta were 0.269, 0.732, 0.629, 0.029, and 0.812. Ta had best correlation with both Dr and Dl. The calculation formulas for Dr and Dl using Ta were as follows; Dr=0.32xTa+0.87 cm, and Dl=0.36xTa-0.08 cm. On the other hand, the multiplex calculation formulas of Dr or Dl with H, W, and Ta were as follows; Dr=0.18Ta+8.54x(W/H)+0.75 (r=0.768), and Dl=0.26Ta+5.90x(W/H)-0.16 (r=0.823). The new regression equations provide superior estimates of renal depth compared to conventional equations. Application of these new formulas into camera-based protocols to determine renal clearances may lead to more accurate measurements of ERPF using technetium-99m-MAG3 scintigraphy. (author)

  2. How good is technetium-99m mercaptoacetyltriglycine indirect cystography?

    International Nuclear Information System (INIS)

    Sadeleer, C. de; Boe, V. de; Keuppens, F.; Desprechins, B.; Verboven, M.; Piepsz, A.

    1994-01-01

    The aim of the present study was to estimate the sensitivity of indirect radionuclide cystography (IRC) performed with technetium-99m mercaptoacetyltriglycine (MAG3), in comparison with the micturition cystourethrography (MCUG) and direct radionuclide cystography (DRC), for the diagnosis of vesicoureteric reflux. Two groups of patients were selected: group I comprised 40 children who underwent IRC during the acute phase of urinary tract infection and an MCUG 6 weeks later; group II comprised 42 (other) children with known reflux, who underwent IRC and DRC during follow-up. Taking as the reference the total number of refluxing kidneys detected by means of any cystographic technique, 99m Tc-MAG3 ICR missed two-thirds of the refluxing kidneys. Most of the small refluxes were missed, but so too were 50% of the major refluxes. Taking as the reference 99m Tc dimercaptosuccinic acid (DMSA) scintigraphy, MCUG detected 91% of the patients with DMSA abnormalities on at least one kidney, DRC detected 95%, and IRC detected 46% and 43% respectively, in groups I and II. The use of 99m Tc-MAG3 IRC as the sole technique for the detection of vesicoureteric reflux gives rise to an unacceptable number of false-negative results. (orig.)

  3. Multicenter trial validation of a camera-based method to measure Tc-99m mercaptoacetyltriglycine, or Tc-99m MAG3, clearance.

    Science.gov (United States)

    Taylor, A; Manatunga, A; Morton, K; Reese, L; Prato, F S; Greenberg, E; Folks, R; Kemp, B J; Jones, M E; Corrigan, P E; Galt, J; Eshima, L

    1997-07-01

    To evaluate an improved camera-based method for calculating the clearance of technetium-99m mercaptoacetyltriglycine (MAG3) in a multicenter trial. Tc-99m MAG3 scintigraphy was performed in 49 patients at three sites in the United States and Canada. The percentage of the injected dose of Tc-99m MAG3 in the kidney at 1-2, 1.0-2.5, and 2-3 minutes after injection was correlated with the plasma-based Tc-99m MAG3 clearances. The data were combined with the results obtained in 20 additional patients in a previously published pilot study. Regression models correlating the plasma-based Tc-99m MAG3 clearance with the percentage uptake in the kidney for each time interval were developed; there was no statistically significant difference among sites in the regression equations. Correction for body surface area statistically significantly (P time interval. For the 1.0-2.5-minute interval, the body surface area-corrected correlation coefficient for the four combined sites was .87, and it improved to .93 when one outlier was omitted from the analysis. Similar results were obtained with the other time intervals. Independent processing by two observers showed no clinically important differences in the percentage dose in the kidney or in relative function. An improved camera-based method to calculate the clearance of Tc-99m MAG3 was validated in a multicenter trial.

  4. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Schofer, O. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Koenig, G. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bartels, U. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bockisch, A. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Piepenburg, R. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Beetz, R. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Meyer, G. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany); Hahn, K. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany)

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm{sup 2} body surface) in addition to normal oral fluid intake, weight-related dose of {sup 99m}Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ``normal`` with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  5. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    International Nuclear Information System (INIS)

    Schofer, O.; Koenig, G.; Bartels, U.; Bockisch, A.; Piepenburg, R.; Beetz, R.; Meyer, G.; Hahn, K.

    1995-01-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm 2 body surface) in addition to normal oral fluid intake, weight-related dose of 99m Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ''normal'' with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  6. Use of [sup 99m]Tc mercaptoacetyltriglycine (MAG3) for detection of renal lesions after ESWL. A prospective study with 117 patients. [sup 99m]Technetium-Mercaptoacetyltriglycin (MAG3) zum Nachweis von Nierenveraenderungen nach extrakorporealer Stosswellenlithotripsie. Eine prospektive Untersuchung bei 117 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Schaub, T. (Klinik mit Poliklinik fuer Radiologie, Universitaetsklinik Mainz (Germany)); Witsch, U.; El-Damanhoury, H. (Klinik mit Poliklinik fuer Urologie, Universitaetsklinik Mainz (Germany)); Naegele-Woehrle, B.; Hahn, K. (Klinik mit Poliklinik fuer Nuklearmedizin, Universitaetsklinik Mainz (Germany))

    1992-10-01

    Extracorporeal shock wave lithotripsy (ESWL) has become the treatment of choice for urinary calculi. 117 patients were studied prospectively with [sup 99m]Tc Mercaptoacetyltriglycine (MAG3) before and after ESWL. 79 (66%) of the 119 kidneys treated had abnormal findings. Of these 63/119 (53%) had abnormal scans. 41 (65%) had focal lesions with a delayed intrarenal transport. The remaining 22 had a diffuse delay of intrarenal transport. A loss of relative renal function of 3% and more compared to the pretreatment values was observed in 50/119 (42%) patients. [sup 99m]Tc MAG3 should be done routinely together with radiologic tests (CT or MRI) before and after ESWL to select the patients at risk for post ESWL hypertension. (orig.).

  7. Use of 99mTc mercaptoacetyltriglycine (MAG3) for detection of renal lesions after ESWL

    International Nuclear Information System (INIS)

    Schaub, T.; Witsch, U.; El-Damanhoury, H.; Naegele-Woehrle, B.; Hahn, K.

    1992-01-01

    Extracorporeal shock wave lithotripsy (ESWL) has become the treatment of choice for urinary calculi. 117 patients were studied prospectively with 99m Tc Mercaptoacetyltriglycine (MAG3) before and after ESWL. 79 (66%) of the 119 kidneys treated had abnormal findings. Of these 63/119 (53%) had abnormal scans. 41 (65%) had focal lesions with a delayed intrarenal transport. The remaining 22 had a diffuse delay of intrarenal transport. A loss of relative renal function of 3% and more compared to the pretreatment values was observed in 50/119 (42%) patients. 99m Tc MAG3 should be done routinely together with radiologic tests (CT or MRI) before and after ESWL to select the patients at risk for post ESWL hypertension. (orig.) [de

  8. Clinical comparison of technetium-99m-EC, technetium-99-m-MAG3 and Iodine-131-OIH in renal disorders

    International Nuclear Information System (INIS)

    Kabasakal, L.; Turoglu, T.; Oensel, C.

    1995-01-01

    Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of 99m Tc-EC were studied by constant infusion technique and compared with 99m Tc-MAG3 and 131 I-OIH in 11 patients with various renal disorders. After giving a 7.4 MBq 131 I-OIH and 90-110 MBq 99m Tc-EC or 99m Tc-MAG3 bolus, a constant infusion (MBq/ml) 99m Tc--agent and 0.07 MBq/m 131 I-OIH was started. Sixteen blood and five urine samples were obtained over three hr. The renal clearance of 99m Tc-EC was higher than than of 99m Tc-MAG3. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH ratios were 0.75 ± 0.05 and 0.55 ± 0.10 (p=0.00087), respectively. The distribution volume of 99m Tc-EC was also higher than that of 99m Tc-MAG3 (15722 ± 4644 and 9509 ± 2788 ml/1.73m 2 , respectively; p=0.072). The 99m Tc-EC/OIH and 99m Tc-MAG/OIH distribution volume ratios were 1.03 ± 0.14 and 0.55 ± 0.10, respectively (p = 0.0003). The 60-min excretion values of 99m Tc-EC and 99m Tc-MAG3 were compared to that of OIH. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH excretion ratios were 0.96 ± 0.06 and 1.07 ± 0.10, respectively (p=0.162). The protein binding of 99m -EC and OIH were found to be 34% ±4 and 66% ±5, respectively (p 99m Tc-EC was negligible (3% ±1.2) in comparison to OIH (27% ±3; p 99m Tc-EC. This agent has good potential for renal function evaluation. 32 refs., 5 tabs

  9. Comparison of differential renal function using technetium-99m mercaptoacetyltriglycine (MAG3) and technetium-99m dimercaptosuccinic acid (DMSA) renography in a paediatric population

    Energy Technology Data Exchange (ETDEWEB)

    Ritchie, Gillian; Wilkinson, Alistair G. [Royal Hospital for Sick Children, Edinburgh (United Kingdom); Prescott, Robin J. [University of Edinburgh Medical School, Medical Statistics Unit, Public Health Sciences, Edinburgh (United Kingdom)

    2008-08-15

    In children who have undergone both {sup 99m}Tc-DMSA and {sup 99m}Tc-MAG3 studies for the assessment of differential renal function (DRF) and drainage, respectively, we have noticed good agreement between the calculated DRF values, and hypothesized that there is no significant difference in DRF values calculated from these tests. Therefore, both tests may not always be necessary. To determine whether there is a statistically significant difference between DRF values calculated using {sup 99m}Tc-DMSA and those calculated using {sup 99m}Tc-MAG3. We retrospectively identified children imaged with {sup 99m}Tc-DMSA and {sup 99m}Tc-MAG3. We recorded DRF values, age, indication, and renal pelvis diameter. For the {sup 99m}Tc-DMSA studies we recorded the imaging time after injection. For the {sup 99m}Tc-MAG3 studies we recorded the delay between injection and data acquisition, diuretic use and evidence of delayed drainage or reflux. We identified 100 episodes in 92 children where both {sup 99m}Tc-DMSA and {sup 99m}Tc-MAG3 scans had been performed within a few days. The commonest indication was urinary tract infection or pelviureteric junction obstruction. The mean age of the children was 6.96 years. A significant but clinically acceptable trend was seen between abnormal DRF and difference between tests. A significant link was found with the difference between tests and the time of imaging after DMSA injection, and also with scarring. No significant effect was caused by renal pelvis dilatation, delayed drainage, frusemide administration, or delayed {sup 99m}Tc-MAG3 imaging. If a {sup 99m}Tc-MAG3 study has been performed then a {sup 99m}Tc-DMSA study is unnecessary provided DRF is normal on the {sup 99m}Tc-MAG3 study and there is no scarring. A change in practice would lead to considerable savings in time, cost and radiation burden. (orig.)

  10. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  11. Clinical comparison of I-131 orthoiodohippurate and the kit formulation of Tc-99m mercaptoacetyltriglycine

    International Nuclear Information System (INIS)

    Taylor, A. Jr.; Ziffer, J.A.; Steves, A.; Eshima, D.; Delaney, V.B.; Welchel, J.D.

    1989-01-01

    Previous studies in animals and humans have shown that technetium-99m mercaptoacetyltriglycine (MAG3) purified by high-performance liquid chromatography is a renal tubular agent with characteristics similar to those of iodine-131 orthoiodohippurate (OIH). A kit formulation for Tc-99m MAG3 has been developed and compared with I-131 OIH in 17 patients with suspected renal dysfunction and three potential kidney donors. There were no adverse reactions. Tc-99m MAG3 images were of good quality and consistently better than I-131 OIH images. There was no significant difference in the relative renal uptake of Tc-99m MAG3 and I-131 OIH. The 30-minute urinary excretion of Tc-99m MAG3 was 36.4%, versus 40.4% for I-131 OIH. The average plasma clearance of Tc-99m MAG3 (138 mL/min +/- 117) was less than that of I-131 OIH (272 mL/min +/- 205) (P less than .001); however, there was good correlation between the Tc-99m MAG3 and I-131 OIH clearances (r = .87). The volume of distribution of Tc-99m MAG3 (5.96 L +/- 1.94) was less than that of I-131 OIH (9.41 L +/- 3.73) (P less than .001). These characteristics and the advantages of a simple kit formulation should lead to widespread clinical use

  12. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  13. Tc-99m MAG3 SPECT on transplanted kidney

    International Nuclear Information System (INIS)

    Ryu, Jong Gul; Kim, Soon; Zeon, Seok Kil

    1999-01-01

    This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 paints with renal arterial variation showed focally decreased radioactivity and SPECT helped guide further studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings

  14. Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study

    International Nuclear Information System (INIS)

    Piepsz, A.; Gordon, I.; Hahn, K.; Kolinska, J.; Kotzerke, J.; Sixt, R.

    1993-01-01

    A multicentree European study was undertaken in order to determine a reasonable algorithm allowing the determination of overall technetium-99m mercaptoacetyltriglycine clearance using a single blood sample. Employing multiple blood sample clearance as a reference method, it was shown that an acceptable estimation of the MAG3 renal clearance could be obtained using a blood sample taken at any time between 30 and 40 min after tracer injection. After correction for body surface area comparison of clearance determined using (a) the single blood sample and (b) the multiple blood samples provided a coefficient of correlation of 0.949 and an SEE of 27 ml/min. This algorithm is valid for clearance values higher than 100 ml/min/1.73 m 2 and for children older than 1 year of age. (orig.)

  15. Evaluation of renal function using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Takayama, Teruhiko; Aburano, Tamio; Shuke, Noriyuki

    1993-01-01

    The utility of 99m Tc-mercaptoacetyltriglycine (MAG3) was studied clinically. In the renography obtained with 99m Tc-MAG3, the abdominal aorta and the common iliac arteries were clearly visualized in the vascular phase. Due to less background activity and high target to background ratio, the quality of 99m Tc-MAG3 image was superior to that of 123 I-OIH or 99m Tc-DTPA image. The parameters on the renogram including T max , T 2/3 , and T 1/2 were compared. The correlation of T max and T 2/3 or T 1/2 were not significant between 99m Tc-MAG3 and 123 I-OIH. Another parameter of C 20 /C max , where C 20 and C max are renal activities at 20 min after injection and at T max respectively, showed an excellent correlation between 99m Tc-MAG3 and 123 I-OIH. Using C 20 /C max , pattern of renogram can be characterized numerically. Concerning the relation between C 20 /C max and renogram pattern, standard renogram pattern showed the C 20 /C max value of less than 0.4, while hypofunctioning pattern showed more than 0.5. The correlation coefficient between the renal uptake of 99m Tc-MAG3 and 123 I-OIH was 0.880 with a correlation plot: 'Y=1.16X-0.043', where X and Y represent renal uptake of 99m Tc-MAG3 and 123 I-OIH, respectively. It can be concluded that 99m Tc-MAG3 is a useful renal imaging agent as an alternative to 123 I-OIH, in order to evaluate the proximal tubular function and calculate ERPF. (author)

  16. The development and characterization of Tc-99m mecaptoacetyltriglycine (MAG3)

    International Nuclear Information System (INIS)

    Taylor, A. Jr.; Eshima, D.

    1990-01-01

    I-131 orth-iodohippuric (OIH) acid is a widely used renal radiopharmaceutical but it is limited due to the suboptimal imaging properties of the I-131 radionuclide and the relatively high radiation dose. Recent work has focused on the development of Tc-99m renal tubular function agents which would utilize the optimal radionuclidic properties and availability of Tc-99m, provide comparable clinical information to that obtained with OIH and allow the evaluation of renal perfusion. The triamide mercaptide (N 3 S) donor ligand system has yielded the most promising Tc-99m tubular function agent to date. Tc-99m mercaptoacetyltriglycine MAG 3 does not enter the red blood cell. A simple kit formulation has been developed which yields a stable Tc-99m MAG 3 complex in high radiochemical purity. Studies in normal volunteers and patients indicate that Tc-99m MAG 3 is an excellent Tc-99m renal tubular agent but its clearance is only 50-60% that of OIH. 42 refs., 2 tabs., 2 figs

  17. Evaluation of 99mTc-MAG3 (mercaptoacetyltriglycine) renography for pediatric patients

    International Nuclear Information System (INIS)

    Tabuchi, Kojiro; Adachi, Itaru; Doi, Kenji; Hou, Nobuyoshi; Komori, Tsuyoshi; Nakata, Yasunobu; Matsui, Ritsuo; Sueyoshi, Kouzou; Narabayashi, Isamu

    1999-01-01

    It is difficult to evaluate renal function with 99m Tc-MAG 3 renography in both adult and pediatric patients. We examined 109 pediatric patients with various renal diseases using 99m Tc-MAG 3 renography. Tenal diseases were classified as follows: 9 vesicoureteral reflux, 4 ureteropelvic junctional stenosis, 3 double pelvis, 23 hydronephrosis, 4 glomerulonephritis, 4 nephrotic syndrome, 24 hemolytic uremic syndrome, 10 others; and 24 patients without abnormal findings on other examinations. After hydration and sedation, 100-200 MBq of 99m Te-MAG 3 was injected intravenously. All patients were placed in the supine position, and dynamic data acquisition at 12 sec/frame x 100 frames was performed from the back. The renograms were prepared with the ROIs (regions of interest) set to include the entire kidney. Tmax and T1/2 of renograms were measured for 26 kidneys with no abnormal findings. The correlations between Tmax or T1/2 and age (days after birth) were determined by a linear or logarithmic function. The logarithmic function (Y=7.49-0.56 log e X, r 2 =0.134) yielded a higher correlation than did the linear function (Y=5.16-0.00194X, r 2 =0.089) between Tmax and age. For T1/2 and age (days after birth), the linear function (Y=8.07-0.00451X, r 2 =0.222) yielded a higher correlation than the logarithmic function (Y=11.9-0.986 log e X, r 2 =0.192). Our findings suggest that prolonged Tmax is normalized more rapidly than T1/2 after birth in infants. A delayed excretion phase is not suggestive of renal dysfunction, but is characteristic of renograms in pediatric patients. Abnormality was detected in all patients with hydronephrosis using 99m Tc-MAG 3 renography. On the other hand, a quantitative study was required because renography detected no abnormality for some of patients with disorders of renal parenchyma. (author)

  18. Assessment of various parameters in the estimation of differential renal function using technetium-99m mercaptoacetyltriglycine

    International Nuclear Information System (INIS)

    Lythgoe, M.F.; Gordon, I.; Khader, Z.; Smith, T.; Anderson, P.J.

    1999-01-01

    Differential renal function (DRF) is an important parameter that should be assessed from virtually every dynamic renogram. With the introduction of technetium-99m mercaptoacetyltriglycine ( 99m Tc-MAG3), a tracer with a high renal extraction, the estimation of DRF might hopefully become accurate and reproducible both between observers in the same institution and also between institutions. The aim of this study was to assess the effect of different parameters on the estimation of DRF. To this end we investigated two groups of children: group A, comprising 35 children with a single kidney (27 of whom had poor renal function), and group B, comprising 20 children with two kidneys and normal global function who also had an associated 99m Tc-dimercaptosuccinic acid scan ( 99m Tc-DMSA). The variables assessed for their effect on the estimation of DRF were: different operators, the choice of renal regions of interest (ROIs), the applied background subtraction, and six different techniques for analysis of the renogram. The six techniques were based on: linear regression of the slopes in the Rutland-Patlak plot, matrix deconvolution, differential method, integral method, linear regression of the slope of the renograms, and the area under the curve of the renogram. The estimation of DRF was less dependent upon both observer and method in patients with two normally functioning kidneys than in patients with a single kidney. The inter-observer comparison among children in either group was not dependent on either ROI or background subtraction. However, in patients with poor renal function the method of choice for the estimation of DRF was dependent on background subtraction, though not ROI. In children with two kidneys and normal renal function, the estimation of DRF from the 24 techniques gave similar results. Methods that produced DRF values closest to expected results, from either group of children, were the Rutland-Patlak plot and matrix deconvolution methods. (orig.)

  19. Preparation, radiochemical purity control and stability of 99mTc-mertiatide (Mag-3)

    International Nuclear Information System (INIS)

    Van Hemert, F.J.; Schimmel, K.J.M.; Van Eck-Smit, B.L.F.; Van Lenthe, H.

    2005-01-01

    Scintigraphic image analysis of 99m Tc-mertiatide (Mag-3, mercaptoacetyltriglycine) clearance provides the determination of the blood flow, the tubular transit time and the excretion as well from both kidneys. Radiopharmaceutical routine recommends a radiochemical purity control before administration of the product to a patient. The main objective of this study is to develop a Mag-3 labeling procedure that fits better than the previous one in our daily routine production of radiopharmaceuticals. Increasing proportions of 99m Tc-Mag-3 were measured during the heating and cooling steps of the Mag-3 labeling procedure. High performance liquid chromatography (HPLC) analysis was used to confirm the results of a rapid radiochemical quality control assay on standard instant thin-layer chromatography-silica gel (ITLC-SG) paper. The reconstitution time takes 20-25 minutes from the harvest of pertechnetate to a ready-for-use calibrated patient syringe. The HPLC profile of 99m Tc-Mag-3 including its minor impurities remains unchanged for 24-48 hours after reconstitution. The application of a programmable Peltier-directed device for heating/cooling provides a better control of the temperature course. The procedure proposed fully meets the labeling criteria recommended by the supplier and can be performed with a minimum of attention within a time-span that we formerly needed for solely the radiochemical purity control assay. Moreover, 99m Tc-Mag-3 prepared in this way seems to be considerably more stable than mentioned in the manufacturer's instructions. (author)

  20. Evaluation of renal function using [sup 99m]Tc-MAG3; Comparison with [sup 123]I-OIH and [sup 99m]Tc-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Teruhiko; Aburano, Tamio; Shuke, Noriyuki (Kanazawa Univ. (Japan). School of Medicine) (and others)

    1993-07-01

    The utility of [sup 99m]Tc-mercaptoacetyltriglycine (MAG3) was studied clinically. In the renography obtained with [sup 99m]Tc-MAG3, the abdominal aorta and the common iliac arteries were clearly visualized in the vascular phase. Due to less background activity and high target to background ratio, the quality of [sup 99m]Tc-MAG3 image was superior to that of [sup 123]I-OIH or [sup 99m]Tc-DTPA image. The parameters on the renogram including T[sub max], T[sub 2/3], and T[sub 1/2] were compared. The correlation of T[sub max] and T[sub 2/3] or T[sub 1/2] were not significant between [sup 99m]Tc-MAG3 and [sup 123]I-OIH. Another parameter of C[sub 20]/C[sub max], where C[sub 20] and C[sub max] are renal activities at 20 min after injection and at T[sub max] respectively, showed an excellent correlation between [sup 99m]Tc-MAG3 and [sup 123]I-OIH. Using C[sub 20]/C[sub max], pattern of renogram can be characterized numerically. Concerning the relation between C[sub 20]/C[sub max] and renogram pattern, standard renogram pattern showed the C[sub 20]/C[sub max] value of less than 0.4, while hypofunctioning pattern showed more than 0.5. The correlation coefficient between the renal uptake of [sup 99m]Tc-MAG3 and [sup 123]I-OIH was 0.880 with a correlation plot: 'Y=1.16X-0.043', where X and Y represent renal uptake of [sup 99m]Tc-MAG3 and [sup 123]I-OIH, respectively. It can be concluded that [sup 99m]Tc-MAG3 is a useful renal imaging agent as an alternative to [sup 123]I-OIH, in order to evaluate the proximal tubular function and calculate ERPF. (author).

  1. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-Clearance

    International Nuclear Information System (INIS)

    Hamscho, N.; Doebert, N.; Menzel, C.; Berner, U.; Zaplatnikov, K.; Gruenwald, F.; Wilhelm, A.; Gossmann, J.; Scheuermann, E.H.

    2005-01-01

    Aim: We evaluated the long-term residual renal function after donor nephrectomy using 99m Tc-mercaptoacetyltriglycin (MAG3)-clearance. Donors, methods: Altogether 49 kidney donors were examined using 99m Tc-MAG3-clearance after nephrectomy for donation to a relative (m:f=11.38; age 55±27 years). The donors were examined 16±8 years postoperatively (1.5-26 years). 42 donors (86%) showed normal creatinine values, whereas the other seven (14%) exhibited slightly elevated levels. 20 donors were examined pre- and postoperatively and compared intraindividually. The kidney function was compared to the age adapted normal values of healthy persons with two kidneys (67-133% of age related mean). Results: After nephrectomy all donors showed a normal perfusion, good secretion, merely physiological intrarenal transit and a normal elimination from the kidneys. The 99m Tc-MAG3-clearance was 69±15% of the normal mean value of healthy carriers of two kidneys regardless of the gender. 20 donors with a preoperative examination showed a significantly reduced total renal function from 84±15% of the mean normal value preoperatively to 60±15% postoperatively (p 99m Tc-MAG3-clearance measured prior to nephrectomy and the clearance levels after nephrectomy. Also, no correlation between the preoperative 99m Tc-MAG3-clearance and the postoperative serum creatinine values could be observed. Althogether, 22% of the donors (11/49) developed arterial hypertension 10±8 years after donation (1-23 years). This corresponds to the normal age prevalence of hypertension in the carriers of two kidneys. Three donors suffered from arterial hypertension prior to the operation. Conclusion: Kidney donors with normal or slightly elevated creatinine values postoperatively show a 99m Tc-MAG3 clearance value of 69% of the mean value of healthy carriers of two kidneys. This may serve as a reference value for healthy carriers of one kidney. In our study we demonstrated a good compensation of the contralateral

  2. [99mTc]MAG3-mannosyl-dextran: a receptor-binding radiopharmaceutical for sentinel node detection

    International Nuclear Information System (INIS)

    Vera, David R.; Wallace, Anne M.; Hoh, Carl K.

    2001-01-01

    Technetium-99m-labeled benzoyl-mercaptoacetylglycylglycyl-glycine-mannosyl-dextran ([ 99m Tc]MAG 3 -mannosyl-dextran) is a receptor-binding radiotracer that binds to mannose-binding protein, a receptor expressed by reticuloendothelial tissue. This agent is composed of a 10.5-kilodalton molecule of dextran and multiple units of mannose, and benzoyl-mercaptoacetylglycylglycyl-glycine (BzMAG 3 ). The tetraflorophenol-activated ester of BzMAG 3 and the imidate of thiomannose were used to covalently attach BzMAG 3 and mannose to an amino-terminated conjugate of dextran. This yielded a 19-kilodalton macromolecule consisting of 3 BzMAG 3 and 21 mannose units per dextran. Dynamic light scattering was used to measure a mean diameter of 5.5 nanometers for BzMAG 3 -mannosyl-dextran and 0.28 microns for filtered Tc-99m sulfur colloid. A preliminary sentinel node detection study employing right fore and hind footpad injections of [ 99m Tc]MAG 3 -mannosyl-dextran and left fore and hind footpad injections of filtered Tc-99m sulfur colloid demonstrated greater sentinel lymph node uptake by the receptor-binding agent

  3. MAG3 renal scintigraphy: improved ability to make anatomical diagnoses in neonates

    International Nuclear Information System (INIS)

    Rossleigg, M.A.; Kainer, G.; Rosenberg, A.R.; Farnaworth, R.H.

    1995-01-01

    Technetium-99m mercaptoacetyltriglycine (MAG3) is the most recently introduced renal radiopharmaceutical in Australia and is established as the agent of choice for use in diuresis renography, particularly in neonates and infants. It provides superior anatomical information compared to previously used agents. Three cases are reported in which MAG3 diuresis renography was performed in neonates, who were found to have hydronephrosis detected antenatally. In two neonates, a previously unrecognized horseshoe kidney was demonstrated and in case 3 there were scan features characteristic of a ureterocele. It is highly unlikely that these abnormalities would have been delineated with 99m Tc dimethyltriamine pentaacetic acid (DTPA) study, as confirmed in case 1, because of the relatively poor uptake of DTPA when compared to MAG3. 6 refs., 3 figs

  4. Synthesis, formulation of nucleo-equipment and biological studies of the {sup 99m} Tc-MAG{sub 3}; Sintesis, formulacion de nucleo-equipos y estudios biologicos de la {sup 99m} Tc-MAG{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Reyes H, L; Lezama C, J; Ferro F, G

    1991-10-15

    Technetium-99m-mercaptoacetyl glycylglycylglycine ({sup 99m}Tc-MAG{sub 3}) is introduced to replace o-iodohippurate (OIH) for renal function studies. In this paper we present the synthesis, labelling and biological evaluation of {sup 99m}Tc- MAG{sub 3} prepared in our laboratory. The precursor s-benzoyl-mercaptoacetyl glycyl glycylglycine (Bz-MAG{sub 3} ) was synthesized by condensation of glycylglycylglycine with chloroacetyl chloride to obtain chloroacetyl glycylglycylglycine and this product was condensate with sodium thiobenzoate. The Bz-MAG{sub 3} was characterized by IR and NMR. The labelling with {sup 99m}Tc was carried out at pH 9.0 using stannous chloride as a reducing agent with heating to boiling for 15 min. The benzoyl group is lost in this step, forming {sup 99m}Tc-MAG{sub 3} complex with radiochemical purity of 99%. The biodistribution properties were evaluated in mice and a rapid renal extraction was apparent at the 10 minutes value (51.65% of the injected dose). The radiotracer was administered to 5 patients showing a good biological behavior. Based on these results, the {sup 99m}Tc-MAG{sub 3} is expected to have widespread clinical utility in Mexico. (Author)

  5. Synthesis, formulation of nucleo-equipment and biological studies of the 99m Tc-MAG3

    International Nuclear Information System (INIS)

    Reyes H, L.; Lezama C, J.; Ferro F, G.

    1991-10-01

    Technetium-99m-mercaptoacetyl glycylglycylglycine ( 99m Tc-MAG 3 ) is introduced to replace o-iodohippurate (OIH) for renal function studies. In this paper we present the synthesis, labelling and biological evaluation of 99m Tc- MAG 3 prepared in our laboratory. The precursor s-benzoyl-mercaptoacetyl glycyl glycylglycine (Bz-MAG 3 ) was synthesized by condensation of glycylglycylglycine with chloroacetyl chloride to obtain chloroacetyl glycylglycylglycine and this product was condensate with sodium thiobenzoate. The Bz-MAG 3 was characterized by IR and NMR. The labelling with 99m Tc was carried out at pH 9.0 using stannous chloride as a reducing agent with heating to boiling for 15 min. The benzoyl group is lost in this step, forming 99m Tc-MAG 3 complex with radiochemical purity of 99%. The biodistribution properties were evaluated in mice and a rapid renal extraction was apparent at the 10 minutes value (51.65% of the injected dose). The radiotracer was administered to 5 patients showing a good biological behavior. Based on these results, the 99m Tc-MAG 3 is expected to have widespread clinical utility in Mexico. (Author)

  6. Comparison of four technetium-99m radiopharmaceuticals for detection and localization of gastrointestinal bleeding in a sheep model

    International Nuclear Information System (INIS)

    Owunwanne, A.; Al-Wafai, I.; Vallgren, S.; Sadek, S.; Abdel-Dayem, H.M.; Yacoub, T.

    1988-01-01

    Four Tc-99 radiopharmaceuticals, Tc-99m sulphur colloid, Tc-99m red blood cells (RBCs), Tc-99m mercaptoacetyltriglycine (MAG3), and Tc-99m DTPA, were studied in an experimental animal model for detection and localization of gastrointestinal (GI) bleeding site in both the upper and lower abdomen. With Tc-99m sulphur colloid and Tc-99m RBCs, it was possible to detect and localize the GI bleeding site in the lower abdomen. With Tc-99m MAG3, it was possible to visualize the bleeding site in both the upper and lower abdomen. However, Tc-99m MAG3 is partially excreted by the liver into the bile, hence it will be difficult to use Tc-99m MAG3 to localize the GI bleeding site in the lower abdomen. With Tc-99m DTPA, it was possible to detect and localize the GI bleeding site simultaneously in both upper and lower abdomen. The overall background radioactivity was reduced considerably by diuresis with frusemide and catheterization of the urinary bladder

  7. Complexes of technetium-99m with tetrapeptides, a new class of 99mTc-labelled agents

    International Nuclear Information System (INIS)

    Vanbilloen, Hubert P.; Bormans, Guy M.; Roo, Michel J. de; Verbruggen, Alfons M.

    1995-01-01

    Tetrapeptides are a class of N4-tetraligands that can efficiently bind 99m Tc. In fact, tetrapeptides can be considered as derivatives of mercaptoacetyltriglycine (MAG3) in which the mercaptoacetyl moiety is replaced by a more stable and easier to handle aminoacyl group. Direct labelling of tetrapeptides with 99m Tc in alkaline medium (pH ≥ 11) in the presence of stannous ions gave a high yield (>95%) of one or two (probably isomeric) radiochemical species. Exchange labelling at different pH values in the presence of stannous tartrate resulted in lower yields of the same 99m Tc-labelled products as those formed during direct labelling. In addition, other radiochemical species were formed of which one was characterized as an oxotechnetium-complex with the cyclisized tetrapeptide. Tetrapeptides with a chiral centre in the first amino acid yield upon labelling with 99m Tc two radiochemical species, probably the two diastereomers with an oxotechnetium core respectively syn and anti with respect to the substituent on the amino acid. Only one diastereomer was observed when the chiral carbon atom is located in the second or third amino acid. Electrophoresis indicated that these new 99m Tc-labelled complexes are neutral in acidic medium and negatively charged in neutral and alkaline conditions. This correlates with a complex in which an oxotechnetium(V) group is bound to the ligand through three deprotonated nitrogen atoms of the amide functions and the free electron pair of the amine nitrogen atom. Biodistribution in mice showed for all studied 99m Tc-labelled tetrapeptides a rapid clearance from the blood mainly by the renal system. The presence of a methyl substituent in the tetrapeptide increased the urinary excretion. 99m Tc-labelledl -glycylalanylglycylglycine showed in mice a urinary excretion comparable to that of 99m Tc-MAG3. Further rise of lipophilicity by introduction of a dimethyl, isopropyl or isobutyryl group leads to increased hepatobiliary handling. It

  8. Evaluation of 99mTc-Mercaptoacetyltriglycine-Biocytin as a new hepatobiliary imaging agent in mice coinjected with bilirubin

    International Nuclear Information System (INIS)

    Kim, Meyoung-kon; Seidel, Juergen; Le Nhat; Kim, In-Sook; Yoo, Tae-Moo; Barker, Craig; Kobayashi, Hisataka; Green, Michael V.; Carrasquillo, Jorge A.; Paik, Chang H.

    1999-01-01

    We evaluated 99m Tc-labeled mercaptoacetyltriglycine ( 99m Tc-MAG3)-biocytin as a hepatobiliary imaging agent in the absence and presence of bilirubin in mice. We then compared its pharmacokinetic parameters; peak liver/heart activity ratio (r max ) and half clearance time (HCT) with those of 99m Tc-labeled diisopropyl-iminodiacetic acid ( 99m Tc-disofenin). Balb/c mice were injected intravenously with hepatobiliary agent ( 99m Tc-MAG3-biocytin or 99m Tc-disofenin) alone or in combination with bilirubin at two doses (7 and 14 mg/kg) dissolved in 5% human serum albumin. Images were acquired every 15 s for 30 min with a gamma-camera equipped with a pinhole collimator. Dynamic images showed rapid hepatic uptake of 99m Tc-MAG3-biocytin, with rapid clearance from the blood and rapid excretion via the biliary system. Its hepatic uptake was not affected by bilirubin coinjection, whereas 99m Tc-disofenin coinjected with bilirubin showed a higher blood background than 99m Tc-disofenin alone. These qualitative findings were reflected in pharmacokinetic parameters, r max and HCT. The r max was obtained from plots of time versus liver/heart activity ratios obtained in equal-area regions of interest over the heart and liver. The HCT was calculated from the hepatic clearance curve from plots of time versus liver activity. 99m Tc-MAG3-biocytin without bilirubin coinjection showed an r max of 8.9±1.3 and an HCT of 399±36 s. These values did not change even when 14 mg/kg of bilirubin were coinjected. By contrast, the parameters for 99m Tc-disofenin with bilirubin were significantly (p max was decreased from 7.9±2.5 to 1.4±0.2 and HCT was increased from 292±32 s to 782±133 s. 99m Tc-MAG3-biocytin hepatobiliary scintigraphy in mice is not affected by bilirubin coinjection, and this hepatobiliary agent appears to offer promise for estimating hepatic function in patients with high bilirubin levels

  9. 99mTc-MAG3: can it be a viable alternative to 99mTc-DTPA ?

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Nair, R.; Gopinath, P.G.

    1991-01-01

    The purpose of this study was to assess the potentials of 99m Tc MAG 3 to replace universally used 99m Tc-DTPA as a routine renal agent. Five patients with different nephrological problems were first studied with 99m Tc MAG 3 and then reinvestigated with 99m Tc-DTPA two to seven days later. Renal MAG 3 gamma camera images were found to be almost identical with those of 99m Tc-DTPA images except high hepatic and splenic uptake of the former compound in four out of five patients (80%) irrespective of kidney function. MAG 3 and DTPA renograms showed identical differential renal uptake function (r=0.87) with slightly higher uptake in right kidneys. Time to reach the peak correlated well (r=0.91). Time to reach half maximum renal activity was also found to be almost identical (r=0.97) for MAG 3 and DTPA. It was felt that the age old 99m Tc-DTPA is as good a compound as 99m Tc MAG 3 with regard to imaging and assessment of renal uptake, drainage and differential renal functions. 99m Tc-DTPA is much cheaper, readily available in India and stable to suit the logistics in a busy nuclear medicine department for routine renography. (author). 10 refs., 2 figs., 3 tabs

  10. Construction of a novel chimera consisting of a chelator-containing Tat peptide conjugated to a morpholino antisense oligomer for technetium-99m labeling and accelerating cellular kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Yumin [Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655 (United States)]. E-mail: yumin.zhang@mpi.com; Tung, C.-H. [Center for Molecular Imaging Research, Massachusetts General Hospital/Harvard Medical School, Charlestown, MA 02129 (United States); He Jiang [Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655 (United States); Liu Ning [Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655 (United States); Yanachkov, Ivan [GlSynthesis, Worcester, MA 01605 (United States); Liu Guozheng [Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655 (United States); Rusckowski, Mary [Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655 (United States); Vanderheyden, Jean-Luc [Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA 01655 (United States)

    2006-02-15

    The attempt to target the limited copies of messenger RNA (mRNA) in vivo with radiolabeled nucleobase oligomers as antisense probes is challenging. Selecting an antisense molecule with superior properties, enhancing the cellular kinetics, and improving the radiolabeling chemistry would be the reasonable approach to accomplish this goal. The present study reports a method to construct a chimera of phosphorodiamidate morpholino nucleobase oligomer (MORF) covalently conjugated to a peptide containing a cell membrane transduction Tat peptide and an N{sub 2}S{sub 2} chelator for technetium-99m ({sup 99m}Tc) radiolabeling (N{sub 2}S{sub 2}-Tat-MORF). The radiolabeling properties and cellular kinetics of {sup 99m}Tc-N{sub 2}S{sub 2}-Tat-MORF were measured. As hypothesized, the preparation of {sup 99m}Tc-N{sub 2}S{sub 2}-Tat-MORF could be achieved by an instant one-step method with labeling efficiency greater than 95%, and the {sup 99m}Tc-N{sub 2}S{sub 2}-Tat-MORF showed distinct properties in cell culture from those of a control, the same MORF sequence without Tat but with mercaptoacetyltriglycine (MAG{sub 3}) as chelator for {sup 99m}Tc ({sup 99m}Tc-MAG{sub 3}-MORF). {sup 99m}Tc-N{sub 2}S{sub 2}-Tat-MORF achieved maximum accumulation of about 35% within 2 h, while {sup 99m}Tc-MAG{sub 3}-MORF showed lower and steadily increasing accumulations but of less than 1% in 24 h. These preliminary results demonstrated that the proposed chimera has properties for easy labeling, and {sup 99m}Tc-N{sub 2}S{sub 2}-Tat-MORF prepared by this method possesses enhanced cellular kinetics and merits further investigation for in vivo mRNA targeting.

  11. Correlation between differential renal uptake of 99mTc-MAG3 and 99mTc-DMSA

    International Nuclear Information System (INIS)

    Obaldo, J.M.; Gruenwald, F.; Menzel, C.; Biersack, H.J.

    1994-01-01

    We reviewed the quantitative indices obtained from sequential 99m Tc-MAG3 and 99m Tc-DMSA imaging studies performed in 134 patients with a variety of renal disorders in order to determine the correlation between the measured differential renal function using these two agents. Overall correlation was high with r=.86 and the derived regression equation was R.F. DMSA =8.2+0.84 (R.F. MAG3 ), where F.F. is the relative function. Highly divergent values for differential function were obtained however in some subjects. Patients with renal obstructive disorders had a correlation coefficient of.81 which was lower than those with nonobstructive pathologies (r=.95). Although relative kidney function measured using 99m Tc-MAG3 and 99m Tc-DMSA correlate significantly, certain patients such as those with renal obstruction may necessitate quantitation using different renal parameters. (orig.) [de

  12. Glomerular filtration and tubular secretion of MAG-3 in the rat kidney

    International Nuclear Information System (INIS)

    Mueller-Suur, R.M.; Mueller-Suur, C.

    1989-01-01

    Technetium-99m mercaptoacetyltriglycine (MAG-3) has recently been introduced as a new radiopharmaceutical for dynamic renal scintigraphy. To elucidate the mechanism of renal excretion, micropuncture experiments were performed in rat kidneys for direct measurements of glomerular filtration and tubular secretory capacity. Fluid of Bowman space was collected from superficial glomeruli and analyzed for its contents of [99mTc]MAG-3, [125I]hippurate and [3H]inulin during constant infusion of these compounds. The ratio of activity of ultrafiltrate to that of arterial plasma was 0.23 for MAG-3, 0.68 for hippurate and 1.04 for inulin which demonstrates that the filtrated amount of MAG-3 is only 23% of that of inulin, presumably because of higher plasma protein binding which was also measured in vitro and found to be 80 +/- 1.5% for MAG-3 and 32 +/- 2% for [125I]hippurate. Proximal and distal tubules were also micropunctured and their tubular fluid as well as the final urine analyzed for the activity of hippurate and MAG-3. The tubular fluid to plasma ratio values along the nephron and in the final urine were all lower for MAG-3 than for hippurate, indicating a lower secretory capacity. From measurements of whole renal clearance, GFR and plasma protein binding the filtered amount of MAG-3 was 0.26 and of hippurate 0.87 ml/min.g kidney weight (p less than 0.001) and the secreted amount 2.01 and 2.38 ml/min.g kidney weight (p less than 0.05), respectively. We conclude that MAG-3 is predominantly excreted by tubular secretion and that the lower renal clearance of MAG-3 as compared with that of hippurate is a result both of a substantially decreased glomerular filtration and of a lower tubular secretion

  13. Evaluation of technetium-99m-Mag3-clearance. A pilot study of industry for the standardization of software

    International Nuclear Information System (INIS)

    Stritzke, H.P.

    1996-01-01

    The manufacturers for gamma camera systems and their distribution organisations in Germany, ADAC, Elscint, Gaede, General Electric, Picker, Siemens, Sopha and Toshiba initiated in cooperation with the Central Association of the Electro and Electronic Industry (Zentralverband der Elektro-und Elektronikindustrie eV, ZVEl), a pilot study to test whether the clinical computer programs for the calculation of the Technetium-99m-Mag 3 Clearance according Bubeck deliver comparable results. For this purpose three dynamic scintigraphic renal studies were converted to interfile format and were sent to the firms at two occasions including blood sampling data and anonymousized patient information. The results were returned to the SAM GmbH System Analysen in der Medizin (Bad Oeynhausen) and analyzed. All of the eight participating firms except one calculated correct clearance values. The reason for the failure in one case turned out to be a bug in the computer program. This pilot study has demonstrated that it is possible to establish certain technical standards for the clinical software in nuclear medicine but also to detect and correct errors. (orig.) [de

  14. Evaluation of the absorbed dose to the kidneys due to Tc99m (DTPA) / Tc99m (Mag3) and Tc99m (Dmsa)

    International Nuclear Information System (INIS)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P.; Idrogo C, J.; Marquez P, F.

    2015-10-01

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc 99m (DTPA) / Tc 99m (Mag3) or Tc 99m (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc 99m (DTPA) / Tc 99m (Mag3), are given by 0.00466 mGy.MBq -1 / 0.00339 mGy.MBq -1 . Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc 99m (DTPA) / Tc 99m (Mag3). The absorbed dose to the kidneys due to Tc 99m (Dmsa) is 0.17881 mGy.MBq -1 . Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc 99m (Dmsa). (Author)

  15. Assessment of renal function with the Tc-99m-MAG3 clearance

    International Nuclear Information System (INIS)

    Keske, U.; Corcles, M.; Andreessen, R.; Wilfling, M.; Roll, D.; Gahl, G.; Felix, R.

    1990-01-01

    This paper evaluates the applicability of the 99m-Tc-mercaptoacetyle-triglycine (MAG3) clearance for the documentation of renal function. Renal clearance was measured with the method of Tauxe in 699 patients during routine renal scintigraphy with 80 MBq of 99mTc-MAG3. Serum creatinine level and MAG3 clearance show an inverse correlation. Patients with an elevated serum creatinine level constantly have a lowered MAG3 clearance and vice versa. For creatinine values lower than 1.8 mg/dL, minor changes in creatinine level are accompanied by large changes in MAG3 clearance. Age (in years) dependence of MAG3 clearance was evaluated in 487 patients who showed no evidence of impaired renal function

  16. Synthesis and evaluation of 99mTc/99Tc-MAG3-biotin conjugates for antibody pretargeting strategies

    International Nuclear Information System (INIS)

    Gog, Frank B. van; Visser, Gerard W.M.; Gowrising, Radjish W.A.; Snow, Gordon B.; Dongen, Guus A.M.S. van

    1998-01-01

    Four 99m Tc-MAG3-biotin conjugates were synthesized to determine their potential use in antibody pretargeting strategies for radioimmunoscintigraphy (RIS). To use these 99m Tc-MAG3-biotin conjugates as model compounds for 186 Re-MAG3-biotin conjugates for radioimmunotherapy (RIT), nanomolar amounts of 99 Tc were added as carrier to 99m Tc. The biotin derivatives used for the preparation of the conjugates - biocytin, biotin hydrazide, biotinyl-piperazine, and biotinyl-diaminosuccinic acid - differed at the site that is regarded to be susceptible to hydrolysis by biotinidase present in human plasma. All four conjugates were produced with high radiochemical purity, were stable in PBS, and demonstrated full binding capacity to streptavidin. The 99m Tc/ 99 Tc-MAG3-labeled biotinyl-piperazine and biotinyl-diaminosuccinic acid conjugates were stable in mouse as well as human plasma, whereas the corresponding biocytin and biotin hydrazide conjugates were rapidly degraded. The biodistribution in nude mice at 30 min after injection was similar for all conjugates, and a rapid blood clearance and high intestinal excretion were both observed. It is concluded that the metabolic routing of a conjugate containing biotin and MAG3 is dominated by these two moieties. For this reason, MAG3-biotin conjugates do not seem suited for pretargeted RIT, for which quantitative and fast renal excretion is a prerequisite to minimize radiation toxicity. However, in a pretargeted RIS approach the 99m Tc-MAG3-biotin conjugates might have potential

  17. The performance of gel technetium-99m generator

    International Nuclear Information System (INIS)

    Liu Yishu

    2004-01-01

    Technetium-99m, as one of the important radionuclides in nuclear medical science, has been widely used for diseases diagnosis in both developed and developing countries for many years. Technetium-99m can be obtained from both fission-type and gel-type Tc-99m generator. Fission-type generator was prepared by Molybdenum-99 separated from fission products of uranium-235 and gel-type was prepared by irradiating nature MoO 3 in reactor, and a series of chemical and physical processes. This paper briefly describes the manufacturing technical process of gel-type Technetium-99 generator, including the preparation of target containing nature MoO 3 , the target irradiation in reactor, gel preparation, gel filtration and drying, dried gel cracking, generator loading and activity calibration of generator. The performances of gel-type Technetium-99m generator, such as elution efficiency, elution profile, the pH, Mo breakthrough, Zirconium content, radiochemical purity, radionuclidic purity, sterility and pyrogencity of eluate, are also expatiated in detail. Comparing with fission-type Technetium-99m generator, the defects of gel-type Technetium-99m generator are enumerated and their overcoming solutions are recommended in this paper. (author)

  18. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  19. Gentc99m, computational system for the technetium-99m generator

    International Nuclear Information System (INIS)

    Suparman, I.

    1997-01-01

    The technetium-99m generator is one of the main products of the PPR, as the continuity of the technetium-99m generator production is important for supporting the development of nuclear medicine. GENTC99M has been made for computational for the technetium-99m generator and includes data processing, documentation and information GENTC99M is also very useful in quality control application especially for the determinations of yield and radionuclidic impurities which consume much time. microsoft visual basic for MS-DOS and visual basic for windows have been used for making GENTC99M. Microsoft visual basic has several features that make it an ideal development language for both MS-DOS and Microsoft Windows. These features not only increase productivity, they also provide all the tools and hooks needed to develop some very sophisticated applications. for a production centre like PPR, GENTC99M is very useful to support the data processing, documentation and information system of the technetium-99m generator and it can also be modified for other products

  20. Method of producing radioactive technetium-99M

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    A chromatographic process of producing high purity and high yield radioactive Technetium-99m. A solution containing Molybdenum-99m and Technetium-99m is placed on a chromatographic column and eluted with a neutral solvent system comprising an organic solvent and from about 0.1 to less than about 10% of water or from about 1 to less than about 70% of a solvent selected from the group consisting of aliphatic alcohols having 1 to 6 carbon atoms. The eluted solvent system containing the Technetium-99m is then removed leaving the Technetium-99m as a dry, particulate residue

  1. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon 'bomb'

    International Nuclear Information System (INIS)

    Varelis, P.; Poot, M.T.

    1998-01-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a 'bomb'. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  2. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon `bomb`

    Energy Technology Data Exchange (ETDEWEB)

    Varelis, P.; Poot, M.T. [St George Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a `bomb`. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  3. Sequential Tc[sup 99m] mercaptoacetyl-triglycine (MAB3) renography as an evaluator of early renal transplant function

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, E.; Greene, A.; Brennan, P.; Donohue, J.; Carmody, M.; Keeling, F. (Department of Radiology and Nephrology, Beaumont Hospital, Dublin, Ireland (United Kingdom))

    1993-01-01

    A prospective study was carried out to evaluate the role of sequential Tc[sup 99m] MAG3 renography in assessing transplant function in the early post-operative period. Twenty patients were included in the study. Studies were performed on all patients at intervals of 48-72 hours until discharge. There were 11 clinically diagnosed episodes of rejection, 9 of which were correctly diagnosed using MAG3 renography. Six episodes of rejection were diagnosed prior to the onset of clinical symptoms. Two patients with graft infarction were correctly diagnosed. Six patients had evidence of transient renographic abnormalities in the immediate post-operative phase which were not associated with clinical symptoms, all of these resolved spontaneously on subsequent examinations and were presumed to be related to resolving acute tubular necrosis (ATN). The perfusion index was of no discriminatory value in this study. Sequential Tc[sup 99m] MAG3 renography is highly sensitive but entirely nonspecific in the evaluation of pathology in the transplant kidney. Rejection in an uncomplicated transplant can be readily detected in many cases well in advance of clinical manifestations. This study demonstrates that Tc[sup 99m] MAG3 renography is certainly equal to Tc[sup 99m] DTPA renography or Iodine 131 renography in assessing early transplant function. However, TC[sup 99m] MAG3 exposes the patient to considerably less radiation and the images are of superior quality. (au) (15 refs.).

  4. Different technetium complexes with mercaptoacetyltriglycine

    International Nuclear Information System (INIS)

    Johannsen, B.; Reiss, H.; Bruch, L.; Modersohn, D.; Noll, B.; Heise, K.H.; Spies, H.; Hoffmann, I.; Hoffmann, S.; Kloetzer, D.

    1990-01-01

    Syntheses performed with unprotected mercaptoacetylglycylglycylglycine (MAG3) both at carrier level (10 -4 M) and with no-carrier-added 99m Tc indicated that various products of different biological properties exist in the Tc/MAG3 system. Besides the known Tc(V)oxo complex recently introduced into nuclear medicine for renal function diagnosis, mainly three species were characterized by HPLC, TLC, electrophoresis and uv-vis spectroscopy as well as biodistribution studies in minipigs. Alteration of preparation conditions such as concentrations, sequence of reactant addition, pH, and time allowed to elucidate reaction routes within the system, interdependence of the species, and vulnerability of the kidney imaging agent. (author)

  5. Triamide mercaptide (N/sub 3/S) ligands for Tc-99m as potential Tc-99m renal function agents

    International Nuclear Information System (INIS)

    Fritzberg, A.R.; Kasina, S.; Johnson, D.L.; Eshima, D.

    1985-01-01

    A number of diamide dimercaptide (N/sub 2/S/sub 2/) complexes of Tc-99m have shown potential as renal tubular function radiopharmaceuticals that could replace radioiodinated hippurate (OIH). Evaluation of such ligands suggested that maximum efficiency for tubular secretion and specificity resulted from addition of a carboxylate group. However, such derivatives resulted in chelate ring stereoisomers that were differently transported by the renal tubular system. The problem of stereoisomers was obviated by replacing one sulfur with an effectively planar amido nitrogen. Groups on the nitrogen then result in diastereomers only when an additional asymetric center is present. A series of triamide mercaptide compounds have been synthesized to evaluate this class as ligands for Tc-99m. One of the simplest of the series, mercaptoacetylglycylglycylglycine (MAG/sub 3/), formed a single Tc-99m product in high yield as determined by HPLC. Preliminary results with pmr and ms of the Tc-99 complex indicate a structure consistent with a 1:1 metal to ligand ratio and monooxo technetium group. Biological evaluation of Tc-99m MAG/sub 3/ showed high renal specificity and rate of excretion exceeding OIH in several species including humans. Members of the N/sub 3/S series studied include mercaptoacetylglycylglycyl-amino acids. In some cases with second asymmetric centers, two components were seen on HPLC. In mice several dianionic Tc-99m complexes were excreted faster than OIH, Tc-99m MAG/sub 2/-ala, -asn, and -gln. Trianionic Tc-99m MAG/sub 2/-asp and -glu were excreted more slowly, and Tc-99m MAG/sub 2/-phe showed hepatobiliary excretion. Triamide mercaptides represent a new ligand class for Tc-99m

  6. Process for producing radioactive technetium 99 m

    International Nuclear Information System (INIS)

    Karageozian, H.L.

    1979-01-01

    Active aluminium oxide containing Molybdenum 99 and technetium 99 m is treated with a neutral solvent consisting of water, methylethylketone and ethanol. Technetium 99 m remains on the chromatographic material after drying, in the form of a dry powder. Other aliphatic alcohols can also be utilised. (DG) [de

  7. A phase 2 clinical study of 99mTc-MAG3 injectable, a dynamic renal imaging agent

    International Nuclear Information System (INIS)

    Torizuka, Kanji; Yamamoto, Kazutaka; Nishibuchi, Shigeo; Ishibashi, Akira; Ikekubo, Katsuji.

    1993-01-01

    A phase 2 clinical study of 99m Tc-mercapto acetyl glycylglycylglycine ( 99m Tc-MAG3) injectable, a new dynamic renal imaging agent, was performed in 110 patients with renal and/or urinary disorders to evaluate the safety, efficacy and optimal dose of this agent. Neither adverse reactions nor abnormal laboratory findings due to intravenous administration of 99m Tc-MAG3 were observed. The investigators evaluated the clinical efficacy of 99m Tc-MAG3 was to be effective in 96 of 97 cases. Among the doses of 92.5 MBq, 370 MBq and 555 MBq, the dose of 92.5 MBq was not large enough to provide adequate-quality blood flow images or reliable information for evaluation of the renal blood flow. It was concluded that the optimal dose range of 99m Tc-MAG3 was 185-555 MBq with 370 MBq as the standard dose. Also, we summarize that 555 MBq is especially recommendable when detailed blood flow information is required. These results indicate that 99m Tc-MAG3 injectable is useful for the diagnosis of renal and urinary disorders. (author)

  8. Analysis of radiochemical purity (RCP) of 99Tcm-MAG3 injection

    International Nuclear Information System (INIS)

    Huang Qingquan; Xia Zhenmin

    1992-01-01

    A two-system paper chromatographic method has been established for the determination of RCP of 99 Tc m -MAG 3 injection. R f -values of 99 Tc m -MAG 3 , 99 Tc m O 4 - and H-R- 99 Tc m (hydrolysis reduced 99 Tc m ) are 0.9, 0.8, 0.0 in system I, and 0.0, 0.4, 0.0 in system II respectively. The RCP and percentages of 99 Tc m O 4 - and H-R- 99 Tc m of 99 Tc m -MAG 3 injection have been determined with this method

  9. Technetium-99 m generator safety simulation

    International Nuclear Information System (INIS)

    Kang, Sang Koo; Kim, Chong Yeal

    2008-01-01

    Technetium ( 99m Tc) is one of the most widely used radioactive isotopes for diagnosis in the world. In general, 99m Tc is produced inside the so called technetium generator where 99Mo decays to 99m Tc. And the generator is usually made out of lead to shield relatively high energy radiation from 99m Tc and 99 Mo. In this paper, a GEANT4 simulation is carried out to test the safety of the 99m Tc generators, taking domestic and Japanese products with radioactivity of 18.50 GBq (500 mCi) for example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of radiation shielder should not exceed 2 mSv∙h -1 and 0.02 mSv∙h -1 , respectively. The simulated dose turned out about only 10% of the limit, satisfying the domestic regulation

  10. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  11. 99mTc-MAG3 vs 99mTc-DMSA early images: A practice options for the study of renal morphology

    International Nuclear Information System (INIS)

    Fraxedas, R.; Reyes, L.; Rodriguez, J.L.; Perera, A.; Solano, M.E.; Sanchez del Campo, M.

    1997-01-01

    99m Tc- DMSA renal scans are considered a gold standard for the evaluations of cortical defects Nevertheless 99m Tc -MAG3 early images (1-2 min after administration) present clearly defined images of the renal parenchyma. In this work 37 patients with clinical suspicion of upper tract infection were studied with both tracers. Renal ages were evaluated for the presence of cortical defects in a blind fashion by a group of three experts and split function was calculated. Results were highly coincident. It is concluded that early 99mT c -MAG3 can be used to study renal morphology and patient irradiated can be reduced

  12. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy; Les radiopharmaceutiques marques au technetium-99m et la radiopharmacie

    Energy Technology Data Exchange (ETDEWEB)

    Bodenant, V

    1998-10-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  13. Technetium-99m somatostatin analogues: effect of labelling methods and peptide sequence

    International Nuclear Information System (INIS)

    Decristoforo, C.; Mather, S.J.

    1999-01-01

    In this paper the preclinical evaluation of the somatostatin analogue RC160 labelled with technetium-99m using bifunctional chelators (BFCs) based on the hydrazinonicotinamide (HYNIC) and N 3 S system is described and a comparison made with [Tyr 3 ]-octreotide (TOC). Conjugates of both peptides with HYNIC, and of RC160 with benzoyl-MAG 3 and an N 3 S-adipate derivative were prepared and radiolabelling performed at high specific activities using tricine, tricine/nicotinic acid and ethylenediamine-N,N'-diacetic adic (EDDA) as co-ligands for HYNIC conjugates. All conjugates and 99m Tc-labelled peptides showed preserved binding affinity for the somatostatin receptor (IC50, Kd 99m Tc-RC160 derivatives compared with 99m Tc-EDDA/HYNIC-[Tyr 3 ]-octreotide (0.2%-3.5%ID/g vs 9.7%ID/g) and correlated well with the reduced internalisation rate for RC160 derivatives. Our results show that the selection of the labelling approach as well as the right choice of the peptide structure are crucial for labelling peptides with 99m Tc to achieve complexes with favourable biodistribution. Despite the relatively low tumour uptake compared with 99m Tc-EDDA/HYNIC-[Tyr 3 ]-octreotide, 99m Tc-RC160 could play a role in imaging tumours that do not bind octreotide derivatives. (orig.)

  14. Influence of different chelators (HYNIC, MAG3 and DTPA) on tumor cell accumulation and mouse biodistribution of technetium-99m labeled to antisense DNA

    International Nuclear Information System (INIS)

    Zhang, Y.M.; Liu, N.; Zhu, Z.-H.; Rusckowski, M.; Hnatowich, D.J.

    2000-01-01

    We have shown recently that cell accumulation in culture of antisense DNA is strongly influenced by the presence of a 99m Tc-MAG 3 group for radiolabeling. We have now compared the in vitro and mouse in vivo behavior of 99m Tc when radiolabeled to one antisense phosphorothioate DNA by three different methods. The 18-mer antisense DNA against the RIα subunit of PKA was conjugated via a primary amine on the 5'-end with the NHS esters of HYNIC and MAG 3 and by the cyclic anhydride of DTPA. Surface plasmon resonance measurements revealed that the association rate constant for hybridization was unchanged for all three chelators as compared with that of the native DNA. Size exclusion HPLC showed rapid and quantitative protein binding for all three chelators upon incubation of labeled DNAs in 37 C serum and cell culture medium. However, in each case, radiolabeled and intact oligonucleotide was still detectable after 24 h. Cellular uptake was tested in an RIα mRNA-positive cancer cell line. The order of cellular accumulation of 99m Tc was DTPA>HYNIC(tricine)>MAG 3 , with the differences increasing with time between 4 and 24 h. The rate of 99m Tc egress from cells was found to be MAG 3 >HYNIC>DTPA, which may explain the order of cellular accumulation. The biodistribution in normal mice was heavily influenced by the labeling method and followed a pattern similar to that seen previously by us for peptides labeled with the same chelators. In conclusion, although these studies concerned only one antisense DNA in one cell line, the results suggest that the success of antisense imaging may depend, in part, on the method of radiolabeling. (orig.)

  15. IL-2 labeled with 99mTechnetium by an indirect method

    International Nuclear Information System (INIS)

    Bocco, R.; Obenaus, Esteban; Rabiller, Graciela; Castiglia, Silvia G. de

    2003-01-01

    IL-2 and the other cytokines labeled with 99m Tc are an interesting option to early diagnosis of autoimmune diseases and monitoring with nuclear medicine images. The aim of this study was to obtain by indirect method IL-2 labeled with 99m Technetium using Benzoyl MAG3 chelating agent, for in vivo diagnosis of lymphocytic infiltration. IL-2 is a small, relatively fragile protein, and it is essential to retain its receptor binding capacity after labeling. Two different methods of labeling have been proven: Pre-conjugation labeling method: we used NHS- Hynic as a chelator agent and labeled this conjugated protein with 99m Tc using tricine as coligand. Albumin was used as a model for the conjugation and labeling steps. The albumin was labeled by this method with a good labeling efficiency but the IL-2 protein could not be labeled with this approach. Post- conjugation labeling method: we used the bifunctional chelating agent, benzoyl MAG3, this ligand is first labeled with 99m Tc and then is conjugated to the protein. The N 3 S Logan complex was incubated for 30 minutes and then measured by RP- HPLC. An active ester of the labeled Logan was formed and was incubated with Il-2 at room temperature and basic pH to promote the conjugation between the active ester and the protein. The labeling efficiency was determined by RP-HPLC using a C 18 column. The albumin protein was also labeled by this method and the radiochemical purity was measured by RP- HPLC using a GPC column and the labeling efficiency was 80%. The next objectives are to explore different strategies for purifying the 99m Tc-IL-2 and to evaluate the capacity of IL-2 to bind to its receptor after labeling. (author)

  16. 99mTc-MAG3 as a single modality investigative agent for evaluation of renal diseases in children

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Handa, R.; Bajpai, M.

    1998-01-01

    Optimal assessment of a child with congenital or acquired renal disease consists of quantitation of renal cortical and excretory function. This at present is routinely done with a 99m Tc-GHA/DMSA and 99m Tc-DTPA scans, respectively. This study was undertaken to assess if 99m Tc-MAG 3 can be utilized as a single modality investigation to provide adequate information about these functions. Sixteen children attending the pediatric urology clinic at All India Institute of Medical Sciences (AIIMS), New Delhi with a variety of renal disorders like posterior urethral valves, hydronephrosis vesicoureteral reflux etc. were included in the study. All the cases were subjected to 99m Tc-MAG 3 , 99m -DTPA and 99m Tc-GHA scans on separate occasions, but as close to one other as possible. The time required for the completion of a 99m Tc-MAG 3 renogram was only twenty minutes. 99m Tc-MAG 3 produced significantly better scintigraphic images of the kidneys and ureters, enabling differentiation between pelviureteric and vesicoureteric junction obstruction. Because of the abundance of photons in 99m Tc-MAG 3 , antegrade ureteric visualization was possible in nine renal units with active ureteric peristalsis appreciable in three renal units. Being a renal tubular agent, it gave a better assessment of renal health of the involved renal unit as compared to 99m Tc-DTPA, a glomerular filtration agent. Detection of renal scars as compared to 99m Tc-GHA showed a sensitivity of 69% and specificity of 93%. Amount of radioactivity required was consistently less than either GHA or DTPA scans. Use of 99m Tc-MAG 3 for renal functional evaluation may result in decreased radiation exposure and optional gamma camera utilization. Besides it is more cost-effective and may reduce the number of investigations that a child needs to be subjected to. It may be of immense value in a country like India where patients have to travel long distances to avail such investigations in a few, overworked nuclear

  17. Validation of alternative methods of preparing 99mTc-MAG3

    International Nuclear Information System (INIS)

    Seetharaman, Shankar; Sosabowski, Michael H.; Ballinger, James R.

    2007-01-01

    Parameters in the preparation of 99m Tc-mertiatide ( 99m Tc-MAG3) were investigated to determine the importance of total activity, activity concentration, boiling time, and delay before boiling for the radiochemical purity (RCP) and stability of the product. Satisfactory RCP results (>90%) were obtained over a range of concentrations including a dilute preparation for paediatric use. RCP was not affected by the time between the addition of pertechnetate and boiling, but low RCP (<60%) resulted when the kit was boiled for less than 10 min

  18. Acetazolamide assisted Tc-99m MAG3 renography to assess renal blood flow reserve

    International Nuclear Information System (INIS)

    Horita, Yoshio; Hayashida, Kohei; Fukuchi, Kazuki

    2003-01-01

    The present study examines whether or not baseline and acetazolamide (ACZ) Tc-99m MAG3 renography can assess renal blood flow reserve. Renography proceeded for 50 min after sequential injections of 370 MBq Tc-99m MAG3 for baseline renography and 10 min after a 1,000 mg injection of ACZ for ACZ renography. Effective renal plasma flow of renal cortex (cERPF) in each kidney and the percentage change in cERPF of those parameters (ΔERPF) were obtained before and after the administration of ACZ in 10 subjects without hypertension or diabetes (normal group), in 10 with essential hypertension (hypertensive group) and in 10 who had Type 2 diabetes with hypertension (diabetic group). A placebo test was performed in the 10 without hypertension or diabetes using distilled water instead of ACZ (placebo group). The placebo test performed in the 10 without hypertension or diabetes using distilled water instead of ACZ indicated that the parameter variance between the two types of renogram was below 3.2%. The cERPF of baseline and ACZ Tc-99m MAG3 renography and ΔERPF in the normal, hypertensive and diabetic groups were 89±10 and 110±10 ml/min, 89±14 and 117±22 ml/min, 100±23 and 112±23 ml/min, respectively, and 24.5±13.5%, 26.0±9.7% and 12.3±11.1%, respectively. The difference in the cERPF value was significant in the normal and hypertensive groups whereas this did not change in the diabetic group before or after ACZ administration. We suggested that the ΔERPF determined by baseline and ACZ Tc-99m MAG3 renography is a useful parameter for assessing renal blood flow reserve. (author)

  19. Radiation decomposition of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1979-01-01

    Technetium-99m radiopharmaceuticals are shown to be subject to autoradiation-induced decomposition, which results in increasing abundance of pertechnetate in the preparation. This autodecomposition is catalyzed by the presence of oxygen, although the removal of oxygen does not prevent its occurrence. The initial appearance of pertechnetate in the radiopharmaceutical is shown to be a function of the amount of radioactivity, the quantity of stannous ion used, and the ratio of /sup 99m/Tc to total technetium in the preparation

  20. Evaluation of total renal function from 99mTc-MAG3 scintigraphy in children

    International Nuclear Information System (INIS)

    Andersson, L.G.; Bratteby, L.E.; Takalo, R.; Svensson, L.

    2002-01-01

    Aim: The aim of the present study was to evaluate the usefulness of dynamic scintigraphy in the assessment of total renal function in children. The Patlak slope of 99m Tc-MAG3 renography curves were compared to the plasma clearance values of 51Cr-EDTA. Material and methods: The study sample consisted of 53 boys and 33 girls with various nephrologic disorders, referred for routine clinical reasons. The median age of the subjects was 5.1 years (range 0.3 - 14.1 years). Imaging procedure. In supine position, the patient received a bolus injection of 1 MBq/kg, (minimum 10 MBq) 99m Tc-MAG3 and a posterior dynamic gamma camera registration was performed for 21 min using 1 frame per second during the first minute and thereafter 10 seconds frames. Data analysis. Time-activity curves were generated from manually drawn heart and renal regions of interest. The MAG3 uptake was calculated from the Patlak-Rutland plot of each kidney by linear curve fitting until the beginning of the excretory phase. A sum of the slope values was used as a measure of total renal MAG3 uptake. Cr-EDTA clearance. Glomerular filtration rate (GFR) was measured from the plasma clearance of 51 Cr-EDTA using single injection, multiple-sample technique. After intravenous injection of 51 Cr-EDTA (74 kBq/kg for children up to 7 years, 37 kBq/kg for children older than 7 years), blood samples were drawn at 5, 10, 15, 45, 60, 120 and 180 min for radioactivity measurement. The GFR was calculated according to Broechner-Mortensen and expressed in ml/min. Results: The absolute 51 Cr-EDTA clearance varied from 9 to 143 ml/min. There was a close linear relationship between 51 Cr-EDTA clearance and MAG3 uptake (Fig). The correlation coefficient was 0.90 and the regression equation (y=43.5 x + 664). Conclusions: In the present study, there was a good correlation between plasma clearance of 51 Cr-EDTA and the sum of the Patlak slopes. The regression equation can be utilised to transform the 99m Tc-MAG3 uptake to an

  1. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    International Nuclear Information System (INIS)

    Bartosch, R.; Granegger, S.; Sinzinger, H.

    1998-01-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of 99m Tc-tetrofosmin and 99m Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.)

  2. 99mTcO(MAG2-3G3-dimer): a new integrin αvβ3-targeted SPECT radiotracer with high tumor uptake and favorable pharmacokinetics

    International Nuclear Information System (INIS)

    Shi, Jiyun; Wang, Lijun; Kim, Young-Seung; Zhai, Shizhen; Liu, Shuang; Jia, Bing; Wang, Fan

    2009-01-01

    This report presents the synthesis of a cyclic RGD dimer conjugate, MAG 2 -G 3 -E[G 3 -c(RGDfK)] 2 (MAG 2 -3G 3 -dimer, G 3 = Gly-Gly-Gly, MAG 2 = S-benzoyl mercaptoacetylglycylglycyl), and evaluation of its 99m Tc complex, 99m TcO(MAG 2 -3G 3 -dimer), as a new radiotracer for imaging the tumor integrin α v β 3 expression. An in vitro displacement assay was used to determine the integrin α v β 3 binding affinity of MAG 2 -3G 3 -dimer against 125 I-c(RGDyK) bound to U87MG human glioma cells. The athymic nude mice bearing U87MG glioma xenografts were used for biodistribution and planar imaging studies. We found that (1) MAG 2 is such a highly effective bifunctional chelator that 99m TcO(MAG 2 -3G 3 -dimer) can be prepared in high yield (radiochemical purity >95%) and with high specific activity (∝5 Ci/μmol) using a kit formulation; (2) 99m TcO(MAG 2 -3G 3 -dimer) has very high solution stability in the kit matrix; and (3) 99m TcO(MAG 2 -3G 3 -dimer) has very fast clearance kinetics from the intestine, liver, and kidneys. Among the 99m Tc-labeled cyclic RGD peptides evaluated in the xenografted U87MG glioma models, 99m TcO(MAG 2 -3G 3 -dimer) has the best pharmacokinetics and tumor to background ratios (tumor/liver = 4.29 ± 1.00 at 30 min postinjection and 8.29 ± 1.50 at 120 min postinjection; tumor/kidney = 1.16 ± 0.19 at 30 min postinjection and 2.49 ± 0.25 at 120 min postinjection). Planar imaging studies showed that tumors in the glioma-bearing mice administered with 99m TcO(MAG 2 -3G 3 -dimer) can be visualized with excellent contrast as early as 15 min postinjection. 99m TcO(MAG 2 -3G 3 -dimer) was able to maintain its chemical integrity in kidneys (>80% intact) and liver (>95% intact) over the 2-h period. However, there was significant metabolism (>50% of the injected radioactivity) detected in both urine and feces samples. 99m TcO(MAG 2 -3G 3 -dimer) is a very attractive radiotracer for early detection of integrin α v β 3 -positive tumors and has

  3. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1977-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate is described. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  4. Validation of alternative methods of preparing {sup 99m}Tc-MAG3

    Energy Technology Data Exchange (ETDEWEB)

    Seetharaman, Shankar [Department of Pharmacy, Guy' s and St Thomas' Hospital, Lambeth Palace Road, London SE1 9EH (United Kingdom); Sosabowski, Michael H. [School of Pharmacy and Biomolecular Sciences, University of Brighton, Moulsecoomb (United Kingdom); Ballinger, James R. [Department of Nuclear Medicine, Guy' s and St Thomas' Hospital, St Thomas Street, London SE1 9RT (United Kingdom)], E-mail: james.ballinger@gstt.nhs.uk

    2007-11-15

    Parameters in the preparation of {sup 99m}Tc-mertiatide ({sup 99m}Tc-MAG3) were investigated to determine the importance of total activity, activity concentration, boiling time, and delay before boiling for the radiochemical purity (RCP) and stability of the product. Satisfactory RCP results (>90%) were obtained over a range of concentrations including a dilute preparation for paediatric use. RCP was not affected by the time between the addition of pertechnetate and boiling, but low RCP (<60%) resulted when the kit was boiled for less than 10 min.

  5. Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes

    Energy Technology Data Exchange (ETDEWEB)

    Bartosch, R.; Granegger, S.; Sinzinger, H. [Department of Nuclear Medicine, University of Vienna (Austria)

    1998-09-01

    Some groups have reported that adsorption of radiopharmaceuticals on disposable plastic syringes can reach levels of almost 50%. This high loss of radioactivity stimulated us to carry out similar studies. Our measurements were done in combination with patient studies. Therefore, we used 2-ml syringes, all of the same brand. The radioactivity in the syringe was measured immediately before and after injection. a total of 500-600 MBq technetium-99m labelled tetrofosmin or technetium-99m furifosmin was administered to 48 patients using four different injection techniques (n = 6 for each technique with each tracer): with needles, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer; with butterflies, 1 min blood incubation at 22 C, 10 or 30 min after preparation of the tracer. Neither in syringes nor in needles or butterflies did more than 7% of the initial radioactivity remain. The entire residual activity in syringe plus needle or syringe plus butterfly together never exceeded the 9% limit. Furthermore, in a pilot study we measured the remaining radioactivity in the vial; here, too, we found no more than 14% of total radioactivity. These findings indicate that total retention of radioactivity during elution and application of {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin with material used in our setting does not approach relevant amounts. (orig.) With 4 figs., 1 tab., 7 refs.

  6. The radiopharmaceuticals labelled with technetium-99m and the radiopharmacy

    International Nuclear Information System (INIS)

    Bodenant, V.

    1998-01-01

    In less than fifty years, the place of nuclear medicine is become primordial. Among all the radiopharmaceuticals used in nuclear medicine, the technetium-99m is the most used because of its physico-chemical properties and its great availability with the molybdenum-99m - technetium-99m generator. Since 1992, the radiopharmaceuticals, the packages, the generators are included in the pharmaceutic monopole. They are now under the reliability of the radio-pharmacist. This thesis has for object to introduce these different radiopharmaceuticals labelled with technetium-99m and to show the primordial place of the radio-pharmacist in a service of nuclear medicine. (N.C.)

  7. Technetium-99m-human fibrinogen

    International Nuclear Information System (INIS)

    Wong, D.W.; Mishkin, F.S.

    1975-01-01

    Exogenous fibrinogen has been successfully labeled with /sup 99m/Tc using a modified electrolytic method. The exact labeling mechanism has not been determined. Experimental data suggest that the labeling process of /99m/Tc-fibrinogen is quite similar to that of /sup 99m/Tc-human serum albumin as reported earlier by Benjamin. Technetium-99m-fibrinogen is stable in human plasma or in 1 percent buffered human serum albumin. A binding efficiency of 76 percent has been achieved with approximately 25 percent clottable protein. The entire labeling procedure requires less than 1 hr of preparation time. This short labeling time in a closed system may allow development of a practical method for labeling autologous fibrinogen, thus eliminating the risk of hepatitis transmission. (U.S.)

  8. 3. Congress of the SA Society of nuclear medicine: Technetium-99m technology

    International Nuclear Information System (INIS)

    Beyers, M.

    1988-08-01

    The Atomic Energy Corporation of SA Limited have been engaged in the manufacture of radioisotopes since 1967, shortly after the SAFARI-1 reactor at Pelindaba was commissioned. Since then the use of radioisotopes in South Africa has grown rapidly and at present 95% of the in vivo diagnostic radioisotopes (radiopharmaceuticals) utilized in nuclear medicine are manufactured locally. Because radioisotopes are applied mainly in sophisticated chemically or mechanically processed forms, production requires not only a skilled production team, but also the appropriate facilities for the manufacture of high-quality products which comply with the necessary safety standards. Compliance with such standards is especially important for the routine production of radiopharmaceuticals for use in nuclear medicine. Over the past 20 years technetium-99m has achieved a dominant position among the diagnostic tools in modern nuclear medicine.The scope of nuclear medicine is expanding continuously and its future lies primarily in the development of new organspecific technetium-99m radiodiagnostic agents. Many improvements and changes have been made to Tc-99m generators, the major source of Tc-99m, since they were introduced to nuclear medicine in the late 1950's. The new Peltek-F sterile Tc-99m generator developed by the Isotope Production Centre is a symbol of progress made. In order to commemorate the launching of the new Peltek-F technetium-99m generator during August 1988 it was decided to publish six papers that were presented at the Third Congress of the Society of Nuclear Medicine held at Bloemfontein during the period 15 - 17 August 1988 by members of the Isotope Production Centre. This will serve as a useful reference on various aspects of technetium-99m technology and will stimulate the use of this product as well as new research in this field

  9. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8.

    NARCIS (Netherlands)

    Krause, S.; Rennen, H.J.J.M.; Boerman, O.C.; Baumann, S.; Cyr, J.E.; Manchanda, R.; Lister-James, J.; Corstens, F.H.M.; Dinkelborg, L.M.

    2007-01-01

    BACKGROUND: The technetium 99 m (99mTc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [99mTc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [99mTc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [99mTc]P483H images were equivalent

  10. Comparison of measurement of 99mTc-MAG3 plasma clearance by single plasma sample and renal uptake ratio

    International Nuclear Information System (INIS)

    Ushijima, Yo; Sugihara, Hiroki; Okuyama, Chio; Okitsu, Sigeyuki; Nii, Takeshi; Nishida, Takuji; Okamoto, Kunio; Maeda, Tomoho

    1997-01-01

    Measurement of 99m Tc-MAG 3 plasma clearance based on one-compartment model (MPC method) is a non-invasive method using the renal uptake ratio. We evaluated the clinical usefulness of this method, compared with effective renal plasma flow (ERPF) using 123 I-OIH and two single-plasma sample methods using 99m Tc-MAG 3 (Russell method and Bubeck method). The ratio of 99m Tc-MAG 3 clearance to ERPF was 1.00±0.26. MPC method correlated well with Russell and Bubeck methods (r=0.904, r=0.897). We conclude that MPC method is a suitable replacement for single-plasma sample method in routine clinical use. (author)

  11. Preparation of a generator of technetium-99m

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    Practical description is given of equipment and operations necessary in the preparation of an isotopic generator of technetium-99m. The preparation and application of the active solution and throughly washed of the chromatographic column have been studied in order to allow molibdenum-99 to be adsorbed on a small band, and the solution of tectium-99m to be eluted with high efficiency and purity. The equipment and accesories used are easy and safety to manage, simplifying operations to be carried out with the active product, eliminating the sterile environment in the shielded cell, and facilitating the preparation of the solution of technetium-99m in sterile and pyrogen-free conditions.(author) [es

  12. Technetium-99m Sestamibi in Multiple Myeloma

    International Nuclear Information System (INIS)

    Saber, R.A.

    2002-01-01

    Technetium-99m 2-methoxy - isobutyl - isonitrile (99mTc-MIBI) has been reported to be useful in evaluating patients with multiple myeloma. The aim of this study is to evaluate the role of technetium-99m sestamibi (99mTc-MIBI) scintigraphy in the diagnosis. staging and follow-up of patients with multiple myeloma. Methods and Materials: twenty-five consecutive patients with multiple myeloma were studied using 99mTc- MIBI. Of the 25 patients included in this study, 6 were in stage I, II in stage II and 8 in stage III. Anterior and posterior whole-body imaging were obtained 20 min after I.V. injection of 740 MBq of 99mTc-MIBI. Four different MIBI patterns could be described in our patients: physiological (P), diffuse (D), focal (F) and combined diffuse and focal (D+F). All patients in stages II and III as well as 3 patients in stage I were treated with chemotherapy (cyclophosphamide and prednisone) then 99mTc-MlBI scans were repeated after 6 courses. Results: in comparison to conventional X-ray skeletal survey, 99mTc-MIBI scans showed a higher number of myeloma bone disease at diagnosis. All patients with stage II and III multiple myeloma were positive with 99mTc-MlBl scans at diagnosis. The pattern of positive MIBI accumulation was diffuse in 13 (52%) patients, focal in 4 (16%) and combined focal and diffuse in 6 (24%) patients. The intensity of 99mTc-MIBI correlated with disease activity as determined by lactate dehydrogenase (LDH), number of plasma cells in bone marrow and serum electrophoresis. There was a direct correlation between 99mTc-MIBI scan result and clinical outcome of patients following 6 courses of chemotherapy. Sensitivity and specificity of 99mTc-MIBI scintigraphy in detecting myeloma bone lesions were 92% and 90% respectively. Conclusion: 99mTc-MIBI scintigraphy is a reliable method to evaluate bone marrow activity in patients with multiple myeloma and follow-up of myeloma bone lesions

  13. Model-based comparison of maternal and foetal organ doses from 99mTc pertechnetate, DMSA, DTPA, HDP, MAA and MAG3 diagnostic intakes during pregnancy

    International Nuclear Information System (INIS)

    Saunders, Margaret; Palmer, Maria; Preece, Alan; Millard, Roger

    2002-01-01

    Organ residence times were calculated for diagnostic intakes of 99m Tc pertechnetate, 2,3-dimercaptosuccinic acid (DMSA), diethylene triamine penta-acetic acid (DTPA), hydroxymethylene diphosphonate (HDP), macroaggregated albumin (MAA) and mercapto-acetyltriglycine (MAG 3 ) during the 1st and 3rd stages of pregnancy and used with the MIRDOSE3 pregnant female phantoms for generation of dose estimates. At stage 3 individual foetal organ doses were estimated via a surrogate phantom based on that for the new-born but with mean dose/cumulated activity (S) values scaled for compatibility with foetal whole body S. Stage 1 or 3 whole foetus doses ranged from 5.2 to 0.77 μGy MBq -1 respectively, analogous to current ICRP estimates for these agents using similar in vivo biodistribution model databases. Most stage 3 maternal and foetal organ doses were similar within a factor of 3, being higher in the foetus than the mother with pertechnetate, DTPA and MAG 3 , and lower with DMSA, HDP and MAA. Doses were more uniformly distributed among foetal organs than in the mother. Placental transfer was greatest with pertechnetate, where dose to the stage 3 foetal thyroid was 60-140 μGy MBq -1 . With each agent there was more placental transfer in stage 3 than in stage 1, but doses to stage 1 whole foetus were always higher, with the contribution from the mother dominant. For DMSA, HDP and MAG 3 the maternal contribution to total foetal body dose exceeded 93% for both stages. (orig.)

  14. Ligand-free, protein-bound technetium-99m iron-dextran enhancement of technetium pyrophosphate uptake in tumours

    International Nuclear Information System (INIS)

    Pojer, P.M.; Jakovljevic, A.C.; Wise, K.N.

    1985-01-01

    The biodistribution of technetium-99m was studied in T-cell lymphoma and selected organs of iron-dextran treated and control mice given technetium-99m pyrophosphate. The results showed that high serum iron levels increased tumour uptake of technetium pyrophosphate. This supports the hypothesis that technetium, in common with other metal-based tumour seeking radiopharmaceuticals, is transported to tumours as a ligand-free protein-bound cation. (U.K.)

  15. Pharmacokinetics of {sup 99m}Tc-MAG{sub 3} and {sup 131}I-OIH. Comparative study based on 2 compartment model analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shuke, Noriyuki; Takashio, Tetsuya; Sato, Junichi [Asahikawa Medical Coll., Hokkaido (Japan). Hospital] [and others

    1996-05-01

    We studied 50 patients with mild to moderate renal dysfunction to compare pharmacokinetics of {sup 99m}Tc-MAG{sub 3} with that of {sup 131}I-OIH. After simultaneous bolus injection of both {sup 99m}Tc-MAG{sub 3} and {sup 131}I-OIH, 8-point venous blood sampling was performed from 2 to 44 min post injection. Aliquoted plasma samples were counted for radioactivity along with the injected standard to obtain % injected dose/ml plasma for each tracer. Using obtained time-concentration data, classical 2 compartment model analysis was performed for both tracers to obtain various pharmacokinetic parameters, including distribution volumes (Vds), intercompartmental rate constants, and plasma clearance. In these parameters, Vd of central compartment, Vd at steady state, central to peripheral inter-compartmental rate constant, and plasma clearance were significantly larger for {sup 131}I-OIH. In all parameters, significant correlation was found between {sup 99m}Tc-MAG{sub 3} and {sup 131}I-OIH. The best correlation was seen in plasma clearance (r=0.891, p<0.0001). Plasma clearance ratio ({sup 99m}Tc-MAG{sub 3}/{sup 131}I-OIH), however, showed weak but significant negative correlation with serum creatinine, although this correlation was not likely to affect the overall correlation of clearance between {sup 131}I-OIH and {sup 99m}Tc-MAG{sub 3}. From these results, we comfirmed that {sup 99m}Tc-MAG{sub 3} clearance could be used as an alternative to {sup 131}I-OIH clearance, although pharmacokinetic behavior of {sup 99m}Tc-MAG{sub 3} was not exactly the same as that of {sup 131}I-OIH. (author)

  16. Bronchoalveolar lavage and technetium-99m glucoheptonate imaging in chronic eosinophilic pneumonia

    International Nuclear Information System (INIS)

    Lieske, T.R.; Sunderrajan, E.V.; Passamonte, P.M.

    1984-01-01

    A patient with chronic eosinophilic pneumonia was evaluated using bronchoalveolar lavage, technetium-99m glucoheptonate, and transbronchial lung biopsy. Bronchoalveolar lavage revealed 43 percent eosinophils and correlated well with results of transbronchial lung biopsy. Technetium-99m glucoheptonate lung imaging demonstrated intense parenchymal uptake. After eight weeks of corticosteroid therapy, the bronchoalveolar lavage eosinophil population and the technetium-99m glucoheptonate uptake had returned to normal. We suggest that bronchoalveolar lavage, with transbronchial lung biopsy, is a less invasive way than open lung biopsy to diagnose chronic eosinophilic pneumonia. The mechanism of uptake of technetium-99m glucoheptonate in this disorder remains to be defined

  17. Labelling of biological structures with technetium 99 m

    International Nuclear Information System (INIS)

    Bernardo Filho, M.

    1988-01-01

    The labelling of red blood cells (RBC) with technetium 99m ( 99m Tc) depends on several factors, as the stannous ion (Sn ++ ) concentration, the time and temperature of incubation, the anticoagulant utilized, the presence of plasma proteins (PP) and others. Although the blinding of 99m Tc with hemoglobin and PP are similar, they appear to have specific characteristics as demonstrated by precipitation with alcohol, acetone, trichloroacetic acid, hydrochloric acid and mercury chloride. The bacterial cultures labeled with Technetium- 99m , at optimal Sn ++ ion concentration, presents a large stability and their viability is not altered by this treatment. The electrophoretic mobility, the hydrophobicity, the cationized ferritin distribution and the adherence to human buccal epithelial cells are not modified either. The possibility of labelling with 99m Tc of planaria and cercariae of Schistossoma mansoni evaluative cycle increases the utilization of this radionuclide to an experimental level. The results described with the labelling of these biological structures with 99m Tc demonstrated that stable labeled and viable operations are obtained. (author)

  18. Model-based comparison of maternal and foetal organ doses from {sup 99m}Tc pertechnetate, DMSA, DTPA, HDP, MAA and MAG{sub 3} diagnostic intakes during pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Margaret; Palmer, Maria; Preece, Alan; Millard, Roger [Centre for Physics and Engineering Research in Medicine, University of Bristol, Bristol Oncology Centre, Horfield Road, Bristol BS2 8ED (United Kingdom)

    2002-10-01

    Organ residence times were calculated for diagnostic intakes of {sup 99m}Tc pertechnetate, 2,3-dimercaptosuccinic acid (DMSA), diethylene triamine penta-acetic acid (DTPA), hydroxymethylene diphosphonate (HDP), macroaggregated albumin (MAA) and mercapto-acetyltriglycine (MAG{sub 3}) during the 1st and 3rd stages of pregnancy and used with the MIRDOSE3 pregnant female phantoms for generation of dose estimates. At stage 3 individual foetal organ doses were estimated via a surrogate phantom based on that for the new-born but with mean dose/cumulated activity (S) values scaled for compatibility with foetal whole body S. Stage 1 or 3 whole foetus doses ranged from 5.2 to 0.77 {mu}Gy MBq{sup -1} respectively, analogous to current ICRP estimates for these agents using similar in vivo biodistribution model databases. Most stage 3 maternal and foetal organ doses were similar within a factor of 3, being higher in the foetus than the mother with pertechnetate, DTPA and MAG{sub 3}, and lower with DMSA, HDP and MAA. Doses were more uniformly distributed among foetal organs than in the mother. Placental transfer was greatest with pertechnetate, where dose to the stage 3 foetal thyroid was 60-140 {mu}Gy MBq{sup -1}. With each agent there was more placental transfer in stage 3 than in stage 1, but doses to stage 1 whole foetus were always higher, with the contribution from the mother dominant. For DMSA, HDP and MAG{sub 3} the maternal contribution to total foetal body dose exceeded 93% for both stages. (orig.)

  19. Under used technetium-99m generators

    International Nuclear Information System (INIS)

    Mushtaq, A.

    2001-01-01

    Health care reform truly has become a global issue and it will undoubtedly have a dramatic impact on the future of nuclear medicine business in particular. A bigger concern within the nuclear medicine community is its competitiveness with other modalities and cost effectiveness.Technetium-99m and its generators are playing key role for the majority of diagnostic scans performed in the world today. Availability of ''9''9''mTc can be increased if it is separated from ''9''9Mo after much shorter growth times. After proper planning with the extra ''9''9''mTc, a significant number of scans can be performed or we would be able to order approximately 30% low activity ''9''9Tc generators to fulfill our requirements

  20. The quality control of technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment

    International Nuclear Information System (INIS)

    Farrington, K.J.

    1983-08-01

    The methods of quality control used for technetium-99m radiopharmaceuticals produced at the AAEC Research Establishment are described for both non-fission and fission derived sources of sodium pertechnetate, technetium-99m labelled radipopharmaceuticals, and reagent kits produced for technetium-99m labelling

  1. Demonstration of Adaptive Functional Differences Seen in Kidneys Accompanying a Nonfunctioning/Hypofunctioning Partner, using Camera Based Tc 99m MAG3 Clearance Measurement Technique

    Directory of Open Access Journals (Sweden)

    Burcu Esen Akkaş

    2012-08-01

    Full Text Available Objective: The aim of this study was to demonstrate the functional compensation that occurs in kidneys which accompany a partner with total or partial loss of renal functioning mass, using camera-based Tc 99m MAG3 clearance technique. Material and Methods: Eighty five patients (43M, 42F, age: 44.8±12.6, range: 18-77 years with normal serum creatinine levels and normal (99m MAG3 renogram curves were enrolled for this retrospective study. Patients were grouped as having; group 1: solitary normal kidney (unilateral atrophied/agenetic (n=23, group 2: normal kidney with contralateral hypoplasic/hypofunctioning kidney (split renal function<30%, (n=24, group 3: bilateral normal kidneys (n=38. The measured camera based Tc 99m MAG3 clearances of normal kidneys in each group were compared. Results: Total Tc 99m MAG3 clearances (mL/min/1.73m 2 were significantly lower in group 1 and group 2 compared to group 3 (281.5±46, 260.5±61.7 and 316.1±84, respectively. Highest isolated Tc 99m MAG3 clearances among normal functioning kidneys were observed in group 1 (281.5±45.6 followed by group 2 (204.4±55 and group 3 (157.5±44. Moderate negative correlation was detected between the Tc99m MAG3 clearances of normal kidneys and contralateral renal function (r=-0.5, p<0.001. Conclusion: Normal kidneys can compensate for the loss of contralateral kidney function via increasing their clearances, which seems to be dependent on the residual function of their partner. Camera based Tc 99m MAG3 clearance measurement is an objective method to demonstrate compensatory differences in renal function seen between kidneys with contralateral normofunctioning, hypofunctioning and nonfunctioning partner. (MIRT 2012;21:56-62

  2. Monoclonal anti-elastin antibody labelled with technetium-99m

    International Nuclear Information System (INIS)

    Oliveira, Marcia B.N. de; Silva, Claudia R. da; Araujo, Adriano C. de; Bernardo Filho, Mario; Porto, Luis Cristovao M.S.; Gutfilen, Bianca; Souza, J.E.Q.; Frier, Malcolm

    1999-01-01

    Technetium-99m ( 99m Tc) is widely employed in nuclear medicine due to its desirable physical, chemical and biological properties. Moreover, it is easily available and normally is inexpensive. A reducing agent is necessary to label cells and molecules with 99m Tc and stannous chloride (Sn C L 2 ) is usually employed. Elastin is the functional protein component of the elastic fiber and it is related with some diseases such as arteriosclerosis, pulmonary emphysema and others. The present study refers to the preparation of the 99m Tc labeled monoclonal anti-elastin antibody. The monoclonal antibody was incubated with an excess of 2-iminothiolane. The free thiol groups created, were capable of binding with the reduced technetium. Labeling was an exchange reaction with 99m Tc-glucoheptonate. The labeled preparation was left at 4 deg C for one hour. Then, it was passed through a Sephadex G50 column. Various fractions were collected and counted. A peak corresponding to the radiolabeled antibody was obtained. Stability studies of the labelled anti-elastin were performed at 0,3 6, 24 hours, at both 4 deg C or room temperature. The biodistribution pattern of the 99m Tc-anti-elastin was studied in healthy male Swiss mice. The immunoreactivity was also determined. An useful labeled-anti-elastin was obtained to future immunoscintigraphic investigations. (author)

  3. Renal 99M-technetium dimercaptosuccinic acid scintigraphy

    International Nuclear Information System (INIS)

    Ajdinovic, B.; Jaukovic, L.; Jankovic, Z.; Krstic, Z.

    2004-01-01

    99m-Technetium dimercaptosuccinic acid (99mTc-DMSA) whose ligand was used as a radioprotective agent and as a chelating compound for metal poisoning was reported to be an excellent renal imaging agent. As 99mTc-DMSA concentrates actively in the proximal convoluted tubule, it gives an image functional renal mass. Its integrity is dependent upon several factors, predominently intrarenal blood flow and intact enzyme function.Considering low radiation dose delivered by 99mTc DMSA and wide pediatric use of this radiopharmaceutical we calculate abnormal findings incidence (%).Results of 592 99m Tc-DMSA renal scintigraphy (348 children), which were classified as: 1. normal, 2. probably normal, 3. equivocal, 4. probably abnormal, 5. abnormal, are presented.Normal results were found in 269 patients (45,4%), 25% of whom was normal and 75% probably normal. Equivocal findings were found in 47 patients (7,9%). Abnormal results were presented in 276 patients (82% abnormal, 18% probably abnormal).The highest abnormal findings incidence was found in patients with congenital anomaly (88%), calculosis (87%) and policystic renal disease (79,3%). The lowest abnormal findings percentage was present in patients with urinary tract infection (12,9%) and arterial hypertension (17,3%)The role 99mTc-DMSA renal scintigraphy in pathology is clear in pyelonephrifis, hydronephrotic kidneys, and pediatric disease (urinary tract infections, congenital anomalies) and is confirmed by our results. (authors)

  4. Radionuclide Basics: Technetium-99

    Science.gov (United States)

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  5. Labelling of metaiodobenzylguanidine (MIBG) with Technetium-99m radionuclide

    International Nuclear Information System (INIS)

    Maula Eka Sriyani; Dini Natanegara; Aang Hanafiah Ws

    2015-01-01

    Various neuroendocrine tumors and their metastases are able to localized and staged by Metaiodobenzylguanidine (MIBG). MIBG is a molecule that has a chemical structure similarities with noradrenaline in the adrenal. The research on 131 I-MIBG has been successfully conducted in the tumor imaging. This research of preparing 99m Tc-MIBG that will be used as a diagnostic agent for adrenal tumors was carried out. MIBG labeling activities with technetium-99m radionuclide were carried out through labeling of MIBG with technetium-99m and radiochemical purity analysis. The labeling of MIBG was carried out using both direct and indirect methods with diethylene triamine pentaacetic acid (DTPA) as a co-ligand. Determination of 99m Tc-MIBG labeling efficiency was performed using paper chromatography with Whatman 3MM/dried acetone and Whatman 31ET/acetonitrile 50%. The results of labeling efficiency using the indirect method with DTPA as a co-ligand was obtained 93.44 ± 1.93%, which the concentration of MIBG was 2 mg/0.5 mL H 2 O, concentration of co-ligand was 37,5 μg of SnCl 2 .2H 2 O and DTPA of 1,125 mg at pH 6.5 for 15 minutes incubation in the room temperature ( 25 °C). (author)

  6. Labelling of Klebsiella pneumoniae with technetium-99m: a preliminary communication

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Pereira, J.A.A.; Boasquevisque, E.M.

    1986-01-01

    The labeling of Klebsiella pneumoniae with technetium-99m (Tc-99m) seems to depend on the stannous ion (Sn ++ ) concentration. Starting at 3μg/ml of this ion is the suspension fluid an uptake of Tc-99m close to 90% was observed. The labeling is apparently strong, since the eluation of Tc-99m, after incubation of the tagged culture, in a water-bath at 37 0 C for several hours, was very weak. The viability of the culture was unaltered after treatment with tin and Tc-99m. (Author) [pt

  7. Evaluation of obstructive uropathy by deconvolution analysis of {sup 99m}Tc-mercaptoacetyltriglycine ({sup 99m}Tc-MAG3) renal scintigraphic data. A comparison with diuresis renography

    Energy Technology Data Exchange (ETDEWEB)

    Hada, Yoshiyuki [Mie Univ., Tsu (Japan). School of Medicine

    1997-06-01

    Clinical significance of ERPF (effective renal plasma flow) and MTT (mean transit time) calculated by deconvolution analysis was studied in patients with obstructive uropathy. Subjects were 84 kidneys of 38 patients and 4 people without renal abnormality (22 males and 20 females) whose age was 53.8 y in a mean. Scintigraphy was done with a Toshiba {gamma}-camera GCA-7200A equipped with a low energy-high resolution collimator with the energy width of 149 keV{+-}20% at 20 min after loading of 500 ml of water and rapidly after intravenous administration of {sup 99m}Tc-MAG3 (200 MBq). At 5 min later, blood was collected and at 10 min, furosemide was intravenously given. Plasma radioactivity was measured in a well-type scintillation counter and was used for correction of blood concentration-time curve obtained from heart area data. Split MTT, regional MTT and ERPF were calculated by deconvolution analysis. Impaired transit was judged from renogram after furosemide loading and was classified into 6 types. ERPF was found lowered in cases of obstruction and in low renal function. Regional MTT was prolonged only in the former cases. The examination with the deconvolution analysis was concluded to be widely used since it gave useful information for the treatment. (K.H.)

  8. Infarction of renal transplant with extrarenal excretion of Tc-99m MAG3 demonstrated by renal scintigraphy

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Kim, Min Woo; Sohn, Myung Hee

    2003-01-01

    A 38-year-old woman with end stage renal disease received a living related donor-renal transplant to the right iliac fossa. She developed anuria a week later. Tc-99m MAG 3 renal scintigraphy demonstrated no perfusion, uptake, or excretion of the radioactive tracer from the renal transplant. The expected area of the renal allograft appeared as a photopenic area with increased rim activity. The gallbladder and bowel activities were observed on delayed images at 24 hours. There was no blood flow within the renal artery on renal doppler examination. This case shows total absence of perfusion and function in the infarcted renal transplant with extrarenal excretion of Tc-99m MAG 3 caused by acute renal artery thrombosis

  9. Extraosseous uptake of 99sup(m)technetium methylene diphosphonate

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of 99 sup(m)technetium methylene diphosphate ( 99 sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of 99 sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  10. A neutral lipophilic technetium-99m complex for regional cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Narra, R.K.; Nunn, A.D.; Kuczynski, B.L.; DiRocco, R.J.; Feld, T.; Silva, D.A.; Eckelman, W.C.

    1990-01-01

    Technetium-99m-DMG-2MP (Chloro[bis[2,3-butanedionedioxime(1-)-0][2,3- butanedionedioximato (2-)-N,N',N double-prime,N'double-prime,N double-prime double-prime,N'double-prime double-prime] (2-methylpropyl borato (2-))technetium]), also known as SQ 32097 is a member of a family of neutral lipophilic compounds generally known as boronic acid adducts of technetium dioxime complexes (BATOs). After i.v. administration, the concentration of [ 99m Tc]DMG-2MP in various regions of the brain appears to be proportional to blood flow. In rats, 1.1% ID was in the brain at 5 min postinjection when the blood contained less than 3% ID. Over 24 hr excretion was 59% in the feces and 23% in the urine. The activity in monkey brain at 5 min was 2.8% ID and it cleared with a t1/2 of 86 min. Autoradiographs of monkey brain sections showed excellent regional detail with a gray/white ratio of 3.6 at 10 min. The distribution of [ 99m Tc]DMG-2MP in the monkey brain corresponds to the known cytoarchitectural pattern of cerebral glucose metabolism. The properties of [ 99m Tc]DMG-2MP make it a potentially useful agent for cerebral perfusion imaging in man

  11. Technetium-99m labeling anti-amastigote polyclonal antibodies of Leishmania amazonensis

    International Nuclear Information System (INIS)

    Araujo, J.G.V.C.; Toledo, V.P.C.P.; Guimaraes, T.M.P.D.; Bernardo-Filho, M.; Simal, C.J.R.; Mota, L.G.; Diniz, S.O.F.; Cardoso, V.N.

    2002-01-01

    Anti-amastigote polyclonal antibody (IgG) was incubated with solutions of stannous chloride and sodium borohidride. After that, 3.7 MBq of technetium-99m ( 99m Tc) was added. A labeling yield of the antibody about 84% was obtained. After filtration of 99m Tc-IgG, the radiochemical purity increased from 84 to 95%. The labeling of IgG with 99m Tc did not modify the immunoreactivity of the antibody, since it was able to identify in vitro and in vivo the specific antigen of Leishmania amazonensis

  12. Biomedical tracers: technetium-99 m complexing sulfur polydentate ligands

    International Nuclear Information System (INIS)

    Bendennoune, A.

    1994-01-01

    Cyclic and acyclic tetra sulfur ligands have been synthesized and some of them have been labelled with technetium-99m. These works have two different aims: 1- Development of methods permitting to obtain easily potential technetium complexing sulfur polydentate chelates. 2- Research of positive and neutral complexes of this metal likely to replace thalium-201 in the coronary flow estimation and [TcO-HMPAO] sup 0 complex in the cerebral scintigraphy, respectively. In this work, first, different ways for obtaining dithioetherdithiols and cyclic tetrathioethers containing functional groups have been carried out, then complexation of the core of nitrutechnetium (TcN) sup 2+ at tracers scale, by dithioetherdithiols, using exchange reaction with [sup 9 sup 9 sup m TcNCl sub 4 ] sup - ion complex or sup 99 sup m TcN Cl sub 2 [P(CH sub 2 CH sub 2 CN) sub 3 ] sub 2 has been studied. Finally, biological distribution in swiss mouse of these technetiated complexes has been studied. 135 refs., 30 figs., 13 tabs. (F.M.)

  13. A method for the preparation of lipophilic macrocyclic technetium-99m complexes

    International Nuclear Information System (INIS)

    Troutner, D.E.; Volkert, W.A.

    1991-01-01

    A procedure for the preparation of technetium complexes applicable as diagnostic radiopharmaceuticals is suggested and documented with 27 examples. Technetium-99m is reacted with a suitable complexant selected from the class of alkylenamine oximes containing 2 or 3 carbon atoms in the alkylene group. The lipophilic macrocyclic complexes possess an amine, amide, carboxy, carboxy ester, hydroxy or alkoxy group or a suitable electron acceptor group. (M.D.). 7 tabs

  14. Chemical and biological studies on the technetium/S-unprotected MAG3-system

    International Nuclear Information System (INIS)

    Johannsen, B.; Noll, B.; Heise, K.H.; May, K.; Syhre, R.; Reiss, H.; Strangfeld, D.; Bruch, L.; Modersohn, D.

    1990-01-01

    Labelling studies performed with S-unprotected mercaptoacetylglycylglycine (MAG 3 ) have shown that various products of different biological properties exist in the Tc-MAG 3 system. Besides the known Tc(V)oxo complex recently introduced into nuclear medicine for renal function diagnosis, mainly three species were characterized by HPLC, TLC, electrophoresis and UV-VIS spectroscopy as well as biodistribution studies in rats and minipigs. Alteration of preparation conditions, both at carrier level (10 -4 M) and with no-carrier-added 99m Tc such as concentrations, sequence of reactants, pH, and time enabled to elucidate reaction routes within the system, interdependency of the Tc species, and vulnerability of the kidney imaging agent. The renal function agent was prepared by reduction of pertechnetate by stannous tartrate in solution of S-unprotected MAG 3 at pH > 11, and subsequent neutralization. (author)

  15. Evaluation of reflux oesophagitis with technetium-99m-labelled ...

    African Journals Online (AJOL)

    Sucralfate binds with denuded protein to form a stable complex to protect the damaged mucosa. By utilising this property, technetium-99m-labelled sucraJfate can be used to demonstrate ulceration in the upper gastro-intestinal tract. Aim: The aim of this study was to evaluate 99mTc-labelled sucralfate in the diagnosis of ...

  16. Method for radiolabeling proteins with technetium-99m

    International Nuclear Information System (INIS)

    Crockford, D.R.; Rhodes, B.A.

    1984-01-01

    In accordance with this invention, a substrate to be radiolabeled with technetium-99m is admixed with a buffered stannous chloride composition having a pH between about 4.5 and about 8.5 wherein the stannous chloride is produced from a non-oxidized tin source, the buffered stannous chloride is purged of oxygen and the buffer comprises a mixture of alkali metal biphthalate and an alkali metal tartrate. Alternatively, the buffer may include alkali metal borate or gentisate. The stannous chloride solution is admixed with the buffer and the resultant mixture is neutralized with sodium hydroxide. The neutralized solution then is admixed with the substrate eventually to be radiolabeled with technetium-99m. This solution is allowed to incubate for several hours (usually over 15 hours) in the absence of oxygen and at room temperature

  17. Detection of esophageal ulcerations with technetium-99m albumin sucralfate

    International Nuclear Information System (INIS)

    Goff, J.S.; Adcock, K.A.; Schmelter, R.

    1986-01-01

    Technetium-99m albumin-sucralfate ([/sup 99m/Tc]Su) can be used to demonstrate peptic ulcer disease in man and animals. We evaluated the usefulness of [/sup 99m/Tc]Su for detecting various grades of esophagitis. [/sup 99m/Tc]Su adhered to the distal esophagus for up to 3 hr in five of six patients with esophageal ulcers but adhered to only two of nine with lesser degrees of esophagitis. No adherence was seen in five patients without esophagitis. Thus, [/sup 99m/Tc]Su may not be useful for detecting any but the most severe grade of esophagitis. Based on these results, we speculate that the previously documented beneficial effects of sucralfate on mild to moderate esophagitis may be due to other mechanisms besides adherence to the ulcerated mucosa

  18. Detection of esophageal ulcerations with technetium-99m albumin sucralfate

    Energy Technology Data Exchange (ETDEWEB)

    Goff, J.S.; Adcock, K.A.; Schmelter, R.

    1986-07-01

    Technetium-99m albumin-sucralfate ((/sup 99m/Tc)Su) can be used to demonstrate peptic ulcer disease in man and animals. We evaluated the usefulness of (/sup 99m/Tc)Su for detecting various grades of esophagitis. (/sup 99m/Tc)Su adhered to the distal esophagus for up to 3 hr in five of six patients with esophageal ulcers but adhered to only two of nine with lesser degrees of esophagitis. No adherence was seen in five patients without esophagitis. Thus, (/sup 99m/Tc)Su may not be useful for detecting any but the most severe grade of esophagitis. Based on these results, we speculate that the previously documented beneficial effects of sucralfate on mild to moderate esophagitis may be due to other mechanisms besides adherence to the ulcerated mucosa.

  19. Technetium 99-m labeled radio-diagnostic agents employing stannous tartrate and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1976-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung. 31 claims, no drawings

  20. The retention mechanism of technetium-99m-HM-PAO

    DEFF Research Database (Denmark)

    Neirinckx, R D; Burke, J F; Harrison, R C

    1988-01-01

    Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation of the b......Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation....... This correspondence of values supports the notion that GSH may be important for the in vivo conversion of 99mTc-labeled HM-PAO to hydrophilic forms and may be the mechanism of trapping in brain and other cells. A kinetic model for the trapping of d,l- and meso-HM-PAO in tissue is developed that is based on data...

  1. Labeling of creatinine with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Yurt Lambrecht, F. [Ege Univ., Bornova, Izmir (Turkey). Dept. of Nuclear Applications, Inst. of Nuclear Sciences; Durkan, K. [Dokuz Eylul Univ., Buca, Izmir (Turkey). Chemistry Technicianship Program, Izmir Vocational School; Soylu, A. [Dokuz Eylul Univ., Narlidere, Izmir (Turkey). Dept. of Pediatrics, Medical Faculty

    2004-07-01

    Creatinine is a clinically important index of renal glomerular filtration rate. Urine creatinine levels can be used as a screening test to evaluate kidney function or can be part of the creatinine clearance test. In case of kidney dysfunction or muscle disorders the creatinine concentration in serum/plasma may rise to a higher value than in healthy body. Technetium- 99m has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. {sup 99m}Tc is utilized to label molecules and cells, used as radiopharmaceuticals, and also to label biological species. It presents many desirable characteristics. SnCl{sub 2} method is frequently used as a reducing agent in the {sup 99m}Tc- labeling process. Creatinine metabolism might be investigated by using labeled {sup 99m}Tc- creatinine in healthy or uremic rats. (orig.)

  2. Preparation and quality control of technetium-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Samuels, D.L.

    1978-11-01

    Appropriate procedures for the production and quality control of technetium-99m based radiopharmaceuticals in hospital radiopharmacy consistent with the recently published Australian Code of Good Manufacturing Practice are discussed

  3. Production technologies for molybdenum-99 and technetium-99m

    International Nuclear Information System (INIS)

    1999-02-01

    Technetium-99m (6.02 h) is the most widely used radioisotope in nuclear medicine, accounting for more than 80% of all diagnostic nuclear medicine procedures. It is almost exclusively produced from the decay of its parent 99 Mo. The present sources of 99 Mo are research reactors by using the (n,γ) nuclear reaction with natural Mo ( 98 Mo, ∼24%), resulting in inexpensive but low-specific activity 99 Mo, or by neutron-induced fission of 235 U, which results in expensive but high specific activity 99 Mo. This publication covers several aspects related to the production of 99 Mo and 99m Tc. The contributed papers reflect the current status of the technology and discuss potential alternative methodologies for the production of 99 Mo and 99m Tc for medical use. The first four papers address the technologies using nuclear reactors, including the description of a new method using an aqueous homogenous reactor core for production of fission 99 Mo and the latest development efforts to fabricate 235 U low enriched targets (LEU, 235 U). The next five papers discuss the potential of utilizing particle accelerators and assess the current status of the available nuclear data for the production of both, 99 Mo and 99m Tc with proton and deuteron beams. The last paper discusses a new technology based on gel system for the preparation of 99 Mo/ 99m Tc generators using low specific activity 99 Mo produced in research reactors by the neutron activation of natural and inexpensive molybdenum oxide targets. Each individual paper was indexed and abstracted

  4. Evaluation of renal allograft dysfunction employing dynamic SPECT with 99mTc-MAG3 and graph plot analysis

    International Nuclear Information System (INIS)

    Akahira, Hideaki

    1996-01-01

    To estimate renal blood flow and tubular function in transplanted kidneys, we applied the 4 compartments model and the graphic analysis method to 99m Tc-MAG3 dynamic SPECT and calculated some parameters, i.e. K1 (renal influx rate constant), K3 (tubular transporting rate constant), Vd12 (intrarenal distribution volume), and others. Twenty-three renal transplant recipients were examined and divided into following 3 groups according to their serum creatinine levels (SCr); Group I: less than 13 mg/dl (1.1±0.3, n=7), Group II: 1.4-2.5 mg/dl (1.8±0.3, n=11), and Group III more than 2.6 mg/dl (3.9±0.9, n=5). The K3 value became lower in the order of Group I>II>III, and well correlated with blood urea nitrogen (BUN, r=-0.95, p 99m Tc-MAG3 uptake function, respectively. (author)

  5. Technetium-99m labeled radiodiagnostic agents and method of preparation

    International Nuclear Information System (INIS)

    1976-01-01

    A method of preparing improved technetium-99m labelled radiodiagnostic agents by reducing sup(99m)Tc-pertechnetate with stannous tartrate is given. Human serum albumine (HSA) and 1-hydroxyethylidene-1,1-disodiumphosphonate (HEDSPA), which are useful in scintigraphic examinations of the lung and bone, were labelled in this way

  6. An introduction to technetium-99m generators

    International Nuclear Information System (INIS)

    Abrashkin, S.

    1984-02-01

    The role played by technetium-99m generators in diagnostic medicine, their physical and chemical fundamentals and their main technical characteristics are discussed. This report is intended as a general introduction to a group of reports which summarize the work done on the development and production of the generators, and research on the chemical and physical aspects of the generator systems

  7. Ligand-free, protein-bound technetium-99m. Evidence for tumour localisation

    International Nuclear Information System (INIS)

    Jakovljevic, A.C.; Pojer, P.M.

    1984-11-01

    An hypothesis that cations accumulate in tumours independent of ligand is tested. A preparation of technetium-99m known to be ligand-free (that is, the technetium is protein bound and no other ligand is injected) has been shown to accumulate in a T-cell lymphoma

  8. Technetium-99m HMPAO labeled leukocytes in inflammation imaging

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Yoshikawa, Kyousan; Imazeki, Keiko; Minoshima, Satoshi; Arimizu, Noboru

    1991-01-01

    Technetium-99m-HMPAO (Tc-99m-HMPAO) labeled leukocyte imaging was carried out in 19 patients at 3-5 hr after reinjection. There were no side effects noted. Tc-99m leukocyte images showed gall bladder, colon, kidney, and urinary bladder activity in normal distribution as a result of excretion of the eluted Tc-99m complex. They yielded a sensitivity of 93%, a specificity of 100% and an accuracy of 95%. They were correctly positive in 14 out of 19 cases. But one false negative case was seen in a patient with pyonephrosis showing a lack of renal function with decreased renal blood flow. It was concluded that they have some advantages over In-111 leukocyte images, but we have to consider the fact that the ureteral obstruction or the lack of renal function with decreased renal blood flow may result in a false positive or a false negative case. (author)

  9. Evaluation of the use of technetium Tc 99m diethylenetriamine pentaacetic acid and technetium Tc 99m dimercaptosuccinic acid for scintigraphic imaging of the kidneys in green iguanas (Iguana iguana).

    Science.gov (United States)

    Greer, Leah L; Daniel, Gregory B; Shearn-Bochsler, Valerie I; Ramsay, Edward C

    2005-01-01

    To evaluate the use of scintigraphy involving technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) or technetium Tc 99m dimercaptosuccinic acid ((99m)Tc-DMSA) for the determination of kidney morphology and function in green iguanas (Iguana iguana). 10 healthy iguanas weighing >1.6 kg. Renal scintigraphy was performed by use of (99m)Tc-DTPA in 6 of the iguanas and by use of (99m)Tc-DMSA in all 10 iguanas. After the injection of (99m)Tc-DMSA, scans were performed for each iguana at intervals during a 20-hour period. Renal biopsies were performed in all 10 iguanas after the final scintigraphic evaluation. In iguanas, the use of (99m)Tc-DTPA for renal scintigraphy was nondiagnostic because of serum protein binding and poor renal uptake of the isotope; mean +/- SD (99m)Tc-DTPA bound to serum proteins was 48.9 +/- 9.9%. Renal uptake of (99m)Tc-DMSA produced distinct visualization of both kidneys. Renal uptake and soft tissue clearance of (99m)Tc-DMSA increased over the 20-hour imaging period; mean +/- SD renal uptake of (99m)Tc-DMSA was 11.31 +/- 3.06% at 20 hours. In each of the 10 iguanas, ultrasonographic and histologic examinations of biopsy specimens from both kidneys revealed no abnormalities. Results indicate that the kidneys of iguanas can be evaluated scintigraphically by use of (99m)Tc-DMSA; this technique may be potentially useful for the diagnosis of renal failure in iguanas.

  10. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  11. Diuresis renography; A simultaneous comparison between sup 131 I-hippuran and sup 99 Tc sup m -MAG sub 3

    Energy Technology Data Exchange (ETDEWEB)

    Hvid-Jacobsen, K.; Thomsen, H.S.; Nielsen, S.L. (Koebenhavns Amts Sygehus, Herlev (Denmark). Dept. of Nuclear Medicine)

    1990-01-01

    In 20 patients investigated for unilateral upper urinary tract obstruction diuresis renography was performed simultaneously with {sup 131}I-hippuran and {sup 99}Tc{sup m}-MAG{sub 3} using a gamma camera with dual isotope facilities. Furosemide was administered routinely 20 min after radionuclide injection. No significant differences were found in fractional share between the two kidneys, time to maximal activity, residual activity at 20 and 30 min, or rate of emptying after furosemide administration. The MAG{sub 3} curves showed, however, better counting statistics and on scintigrams with MAG{sub 3} more anatomic details (extent of dilation and site of obstruction) could be seen. It is concluded, that MAG{sub 3} is superior to hippuran in the evaluation of patients with possible unilateral upper urinary tract obstruction by diuresis renography. (orig.).

  12. Advances in technetium chemistry towards 99mTc receptor imaging agents

    International Nuclear Information System (INIS)

    Johannsen, B.; Spies, H.

    1997-01-01

    The development of the chemistry of technetium and its non-radioactive surrogate rhenium has been prompted by the trends and needs of nuclear medicine, which predominantly uses 99m Tc radiopharmaceuticals for a broad range of diagnostics. Technetium-99m is the ideal radioisotope for tomographic single-photon emission tomography (SPECT) imaging due to its nuclear properties (6.2 h, E γ 140 keV) and ready availability through generator systems. Transition metals offer many opportunities for designing molecules by modifying the environment around the core, allowing certain biological properties to be imposed upon the molecule. Whereas research in the past was mainly concerned with biological properties that allow relatively unspecific functional imaging, as in brain or myocardium perfusion studies, nuclear medicine is now requiring more and more biochemical information on low capacity, high specificity targets. Many research groups have become involved in the search for new technetium-based compounds, called the third generation of 99m Tc radiopharmaceuticals, that employ the principles of modern pharmacology to achieve biochemical specificity. There has been considerable interest in imaging CNS and other receptors with 99m Tc receptor-binding ligands. Such a 99m Tc CNS receptor-imaging agent is currently not yet in use because of the significant hurdles to be overcome in attaining this ambitious goal. However, some Tc and Re complexes of remarkable affinity in vitro, and the first high-affinity 99m Tc probes able to label the dopamine transporter in the brain by SPECT imaging prove the feasibility of this approach. (Author)

  13. Measurement of glomerular filtration rate in children using technetium-99m diethylenetriamine penta-acetic acid

    International Nuclear Information System (INIS)

    Aaronson, I.A.; Mann, M.D.

    1985-01-01

    During the past 5 years, we have measured the glomerular filtration rate (GFR) by the slope-clearance method using technetium-99m diethylenetriamine penta-acetic acid technetium-99m-DTPA in 130 infants and children. The results in 22 children have been compared with inulin clearance, and a very good correlation between the two methods of measurement of GFR was demonstrated (r = 0,9616; P less than 0,0001). This study provides further evidence that technetium-99m-DTPA is a satisfactory agent for the clinical measurement of GFR in children

  14. Technetium-99m labeled antisense probes uptake in vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Zhang, Y.X.; Qin, G.M.; An, R.; Cao, G.X.; Cao, W.; Gao, Z.R.

    2002-01-01

    In the arterial wall, smooth muscle cells (SMC) normally exist in a quiescent, differentiated state, representing the contractile phenotype. During the development of atherosclerosis SMC change towards the synthetic phenotype going along with proliferation, chemotactic response and increased monocyte binding. The Fas/Fas ligand/caspase death-signaling pathway, Bcl-2 protein family/mitochondria, the tumor suppressive gene p53, and the proto-oncogene c-myc may be activated in atherosclerotic lesions, and mediates vascular apoptosis during the development of atherosclerosis. The atherosclerotic plaques contained 3-4 fold more c-myc mRNA than those in the normal aortic arteries, while increased Bax and Bak coupled with lack/paucity of Bcl-2 and Bcl-xL are associated with SMC apoptosis in advanced lesions. Methods: 1 Oligonucleotide Conjugation: A solution of single stranded amine-derivatized DNA (100-1000μg) was prepared at a concentration of 2 mg/ml in 0.25M sodium bicarbonate, 1 M sodium chloride, 1mM EDTA, pH8.5. Cell uptake studies: 99m Tc- MAG 3 -DNA radioactivity incorporation into porcine coronary smooth muscle cells in the log and plateau phases, respectively, was determined after different times of incubation at 37. The influence of extracellular 99m Tc- MAG 3 -DNA concentration on SMC uptake was also analyzed. [Results] Essentially complete conjugation was achieved by reverse-phase Sep-Pak C18 chromatography analysis. The MAG 3 -DNA was labeled with 99m Tc at room temperature and neutral pH, with a mean labeling efficiency of 80.11%(s.d=2.96%,n=4). The labeled antisense DNA still remained the ability to hybridize with its complementary DNA. After labeling, the stability of the DNA in saline or serum was retained as determined by reverse-phase Sep-Pak C18 chromatography analysis, except a shift at 30 min in serum incubation that suggesting a short time serum protein binding. 99m Tc-MAG 3 -c-myc uptake plateaued at 60 min and was directly proportional to the

  15. Rapid preparation method for technetium-99m bicisate

    Energy Technology Data Exchange (ETDEWEB)

    Hung, J.C. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Chowdhury, S. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Redfern, M.G. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Mahoney, D.W. [Section of Biostatistics, Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States)

    1997-06-10

    The method currently recommended for the preparation of technetium-99m bicisate ({sup 99m}Tc-bicisate) requires a lengthy 30-min incubation at room temperature. The purpose of this study was to evaluate an alternative method to shorten the preparation time. {sup 99m}Tc-bicisate was prepared with 3.7 GBq (100 mCi) {sup 99m}Tc according to the manufacturer`s instructions, except for the final incubation step, which was replaced with the microwave heating procedure. A standard thin-layer chromatography (TLC) method (i.e., Baker-Flex silica gel IB-F TLC plate with ethyl acetate as mobile phase) was used for the determination of the radiochemical purity (RCP) of {sup 99m}Tc-bicisate. Our evaluation with different microwave heating processes (300 W with different heating times) demonstrated that as the microwave heating temperature was increased (i.e., 44 -71 C), an increased percentage of samples reached 95% within 5 min post preparation (n=58). The highest RCP value (i.e., 97.4%{+-}0.5%, n=10) could be obtained immediately after an 8-s microwave heating time at 300 W (microwave temperature at 69 C), and an average RCP value of 96.4%{+-}1.3% (n=90) was maintained throughout the 24-h evaluation period. However, the trend seemed to reverse at higher microwave temperatures (i.e., 76 -90 C), which reconfirmed our initial findings that overheating had no benefit for the preparation of {sup 99m}Tc-bicisate. To ensure that temperature was the only determining factor, a hot water incubator set at 69 C was used (n=6). Similar RCP results were achieved. In conclusion, the use of a microwave oven at a low heat cycle provides a rapid and efficient way to prepare {sup 99m}Tc-bicisate. (orig.). With 3 figs., 1 tab.

  16. Complex formation of technetium with the methyl esters of MAG2 and MAG1

    International Nuclear Information System (INIS)

    Noll, B.; Noll, S.; Grosse, B.; Johannsen, B.; Spies, H.

    1993-01-01

    Mercaptoacetylglycine methyl ester (MAG 2 ester) and mercaptoacetyldiglycine methyl ester (MAG 1 ester) were included to investigate complex formation of SH/amide ligands with technetium. The studies are aimed at finding out how blocking the carboxylic groups influences the complexation reaction, with a view to finding an approach to new lipophilic species. (orig./BBR)

  17. Technetium-99m-sestamibi scintigraphy in breast nodes; Estudo cintilografico de nodulos mamarios com tecnecio-99m-sestamibi

    Energy Technology Data Exchange (ETDEWEB)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina; Balen, Jacir Luiz; Fabricio, Maria Ines Menescal [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Inst. de Ginecologia; Amarante Junior, Jose Luiz de Medeiros

    1997-01-01

    The purpose was to was to determine if technetium-99m-sestamibi accumulates preferentially within the malignant palpable nodes of breast. Twenty-five patients, mean age 36.16 ({+-} 9.34) year, and without any other additional information, underwent breast scintigraphy and excisional biopsy. We had nineteen true-negative cases, four true-positive, two false-positive and none false-negative. Sensitivity, 100% specificity, 90.5%, accuracy, 92%; PPV, 66.7%, NPV, 100%. The four true positive were invasive intraductal carcinomas and one of them metastases in auxiliary lymph-nodes, confirmed in biopsy and well defined in scintigraphy. The two false-positives were a fibroadenoma with high cellularity and a fibrodisplasy surrounded by chronic inflammatory process. Two statistical tests were applied: chi-square and Fisher. Both rejected the antithesis at a confidence interval of 99% (p , 0.01) We concluded that technetium-99-sestamibi accumulates preferentially within the malignant nodes of breast. (author) 17 refs., 3 figs., 2 tabs.

  18. The impact of technetium-99m-radiopharmaceuticals' design on their biological behavior

    International Nuclear Information System (INIS)

    Jankovic, D.Lj.; Djokic, D.Dj. . E-mail address of corresponding author: drinaj@vin.bg.ac.yu; Jankovic, D.)

    2005-01-01

    The coordination has a great and not always predictable impact on the in-vivo behaviour of the small molecule into which the technetium-bearing chelate units is integrated. The different valence state of technetium in the complexes with some ligands changes the properties of these complexes, such as physico-chemical parameters and biological behaviour. The change of their biological behaviour has a great impact on quality of imaging study and on radiation dose to the patient. The results of the labelling of DPD and EHIDA with 99mTc(I) and their biological behaviour, in comparison with the same one for 99mTc(III)-DPD and 99mTc(III)-EHIDA complexes, confirmed that different oxidation state of 99mTc make possible forming variety of complexes with quite a different and unexpected biological behaviour. (author)

  19. Novel [99mTcN]2+ Labeled EGFR Inhibitors as Potential Radiotracers for Single Photon Emission Computed Tomography (SPECT Tumor Imaging

    Directory of Open Access Journals (Sweden)

    Mingxia Zhao

    2014-04-01

    Full Text Available The epidermal growth factor receptor (EGFR is overexpressed in many cancers, including breast, ovarian, endometrial and non-small cell lung cancer. An EGFR-specific imaging agent could facilitate clinical evaluation of primary tumors or metastases. To achieve this goal, 4-(2-aminoethylamino-6,7-dimethoxyquinazoline (ADMQ was synthesized based on a 4-aminoquinazoline core and then conjugated with N-mercapto- acetylglycine (MAG and N-mercaptoacetyltriglycine (MAG3, respectively, to give compounds 1 and 2. The final complexes [99mTcN]-1 and [99mTcN]-2 were successfully obtained with radiochemical purities of >99% and >98% as measured by radio-HPLC. No decomposition of the two complexes at room temperature was observed over a period of 2 h. Their partition coefficients indicated they were hydrophilic and the electrophoresis results showed they were negatively charged. Biodistribution in tumor-bearing mice demonstrated that the two new complexes showed tumor accumulation, high tumor-tomuscle (T/M ratios and fast clearance from blood and muscle. Between the two compounds, the 99mTcN-MAG3-ADMQ ([99mTcN]-2 showed the better characteristics, with the tumor/muscle and tumor/blood ratios reached 2.11 and 1.90 at 60 min post-injection, 4.20 and 1.10 at 120 min post-injection, suggesting it could be a promising radiotracer for SPECT tumor imaging.

  20. Study on the stability of MAG 3

    International Nuclear Information System (INIS)

    Aungurarat, Angkanan; Ngamprayad, Tippanan; Thuntawewadthananon, Twesak

    2000-01-01

    Tc 9 9m -MAG 3 ([(N-(N-(N-(mercaptoacetyl) glycyl)glycyl) glycinato (2-) N, N', N , S) oxo technetate (2-)]) was prepared for a good renal imaging agent. The two chromatographic methods for analysis of radiochemical purity investigated that the kit could be used with sodium pertechnetate (Technetium-9 9m ) up to 25 mCi, volume 2-5 ml and the Tc9 9m -MAG 3 complex reached maximum at 15 mins. The shelf life of the complex and the expiry date of the kit were 4 hrs and 6 months respectivily

  1. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  2. A camera based calculation of 99m Tc-MAG-3 clearance using conjugate views method

    International Nuclear Information System (INIS)

    Hojabr, M.; Rajabi, H.; Eftekhari, M.

    2004-01-01

    Background: measurement of absolute or different renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods is approximations of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in the use of this technique. In this study the conjugate-view method along with some background correction technique have been used for the measurement of renal activity in 99m Tc- MAG 3 renography. Transmission data were used for attenuation correction and the source volume was considered for accurate background subtraction. Materials and methods: the study was performed in 35 adult patients referred to our department for conventional renography and ERPF calculation. Depending on patients weight approximately 10-15 mCi 99 Tc-MAG 3 was injected in the form of a sharp bolus and 60 frames of 1 second followed by 174 frames of 10 seconds were acquired for each patient. Imaging was performed on a dual-head gamma camera(SOLUS; SunSpark10, ADAC Laboratories, Milpitas, CA) anterior and posterior views were acquired simultaneously. A LEHR collimator was used to correct the scatter for the emission and transmission images. Buijs factor was applied on background counts before background correction (Rutland-Patlak equation). gamma camera clearance was calculated using renal uptake in 1-2, 1.5-2.5, 2-3 min. The same procedure was repeated for both renograms obtained from posterior projection and conjugated views. The plasma clearance was also directly calculated by three blood samples obtained at 40, 80, 120 min after injection. Results: 99 Tc-MAG 3 clearance using direct sampling method were used as reference values and compared to the results obtained from the renograms. The maximum correlation was found between conjugate view clearance at 2-3 min (R=0.99, R 2 =0.98, SE=15). Conventional

  3. 99mTc-tetrapeptides: radiolabelling and biodistribution in rats

    International Nuclear Information System (INIS)

    Laznickova, A.; Laznicek, M.; Trejtnar, F.; Mather, S.J.

    1998-01-01

    Preparation of 99m Tc-labelled tetrapeptides, namely acetyl-Gly-Gly-Cys-Gly (I), acetyl-Ser-Ser-Cys-Gly (II) and acetyl-Gly-Gly-Cys-Lys (III), analysis of their radiochemical purity and biodistribution were investigated in rats. The aim was to determine the relationship between structure and biological behaviour of 99m Tc-labelled peptides which are formed by amino-acid sequences capable of chelating technetium useful as universal chelators in ''hybrid'' peptides composed of receptor-specific part and the part chelating technetium. For labelling with 99m Tc, a conventional transchelation from 99m Tc-gluconate was used and radiolabelled peptides were purified by filtration on Whatman microfilters 12 kD. Radiochemical purity was higher than 98%. Biodistribution studies in rats showed that all agents are rapidly cleared from the body mostly via urine, but some part of administered radioactivity also in the faces was found. The later route of elimination way increased in the order III 99m Tc-MAG3. The results obtained will assist with design of optimal biocompatible tetrapeptides as chelators for formation of hybrid receptor-specific peptides. (author)

  4. Technetium-99m ceftizoxime kit preparation

    International Nuclear Information System (INIS)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento

    2005-01-01

    The aim of this work was to prepare a kit of 99 m Tc-ceftizoxime ( 99m Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99m Tc pertechnetate solution (Na 99m Tc O 4- ) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99m Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of 99m Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for 99 m Tc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99m Tc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ( 99m Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes. (author)

  5. Determination of technetium-99 in environmental and radioactive waste samples

    International Nuclear Information System (INIS)

    Ferencova, M.; Peter Tkac, P.

    2007-01-01

    Technetium is known for its high mobility in a soil-water system in non-reducing aerobic condition and also high bio-availability for plants, because the most stable form of technetium in natural surface environment is pertechnetate which is highly soluble. The chemical form of technetium changes with environmental conditions. Concentration of technetium in the environment is very low, therefore many separation steps are needed for technetium determination. It has been developed a method for the routine determination of technetium-99 from environmental matrices and radioactive wastes using technetium-99m as an internal yield monitor. Technetium-99 is extracted from the soil samples with nitric acid. Many contaminants are co-precipitated with ferric hydroxide and technetium in the supernatant is pre-concentrated and further purified using anion exchange chromatography. Final separation of technetium was achieved by extraction with tetraphenylarsonium chloride in chloroform from sulphuric acid or pure water. The chemical yield is determined through the measurement of technetium-99m by scintillation counting system and the technetium-99 activity is measured using proportional counter after decay of the technetium-99m activity. Typical recoveries for this method are in the order 50-60 % (authors)

  6. An investigation of the effect of the quantity of stannous ion on the quality of technetium-99m labelled albumin

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Rempel, S.; Westendorf, B.A.

    1981-01-01

    The importance of maintaining a low ratio of stannous ion to albumin molecules in order to obtain a high quality technetium-99m labelled albumin is demonstrated. It is further shown that the direct preparation of technetium-99m albumin by reduction of the technetium-99m pertechnetate with stannous ion inevitably leads to the contamination of the product with a certain amount of tin colloid which is also labelled with technetium-99m. It is demonstrated that this can be avoided by utilizing labelling techniques involving the initial formation of other technetium chelates which are less stable than the albumin complex under certain conditions, adding the albumin to that preparation, adjusting the conditions and thus allowing the albumin to become labelled with technetium-99m via an exchange with the original chelating agent. (author)

  7. Study on the stability of MAG 3

    CERN Document Server

    Aungurarat, A; Thuntawewadthananon, T

    2000-01-01

    Tc 9 sup 9 sup m -MAG 3 ([(N-(N-(N-(mercaptoacetyl) glycyl)glycyl) glycinato (2-) N, N', N sup , S) oxo technetate (2-)]) was prepared for a good renal imaging agent. The two chromatographic methods for analysis of radiochemical purity investigated that the kit could be used with sodium pertechnetate (Technetium-9 sup 9 sup m) up to 25 mCi, volume 2-5 ml and the Tc9 sup 9 sup m -MAG 3 complex reached maximum at 15 mins. The shelf life of the complex and the expiry date of the kit were 4 hrs and 6 months respectivily.

  8. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    International Nuclear Information System (INIS)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.; Barker, K.K.; Ice, R.D.

    1982-01-01

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated with other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate

  9. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  10. MAG3 diuresis renography and output efficiency measurement in renal transplant patients

    International Nuclear Information System (INIS)

    Spicer, T.; Gruenewald, S.; Chi, K.K.; Larcos, G.; Farlow, D.; Choong, K.; Chapman, J.

    1997-01-01

    Full text: Urinary tract obstruction following renal transplantation often presents a diagnostic dilemma, as some patients with equivocal investigations subsequently show improvement following stenting. The purposes of this study were to (1) establish a normal range of renal output efficiency (ROE) in transplants, and (2) assess the usefulness of MAG3 diuresis renography and ROE in suspected allograft obstruction. Twenty-two renal transplant patients with stable function and no evidence of hydronephrosis on serial ultrasound had a diuretic MAG3 scan with calculation of ROE. Three patients with proven graft obstruction underwent the same scanning procedure. Methodology was as follows: (1) 60 MBq of 99m Tc-DTPA GFR was performed (single injection-dual blood sample method); (2) patients were then prehydrated with either oral or IV fluid; (3) 10 min prior to scanning, intravenous Frusemide 20-80 mg (dose depending on renal function) was injected, and then (4) 200 MBq of MAG3 for a 20 min scan. The studies were then qualitatively and quantitatively reviewed to assess uptake and excretion, and the ROE was calculated. The mean ROE for the twenty-two normal renal transplant patients was 85.7% ± 4.1% (range 78 - 90%). Technetium-99m-DTPA GFR was 55.5 mL/min/1.73m 2 (range 27 to 83). The MAG3 scans in the three obstructed patients were equivocal for obstruction but the ROE values of 59%, 68% and 75% were more than 2.5 standard deviations below our calculated normal mean. The 99m Tc-DTPA GFRs were 61,17 and 57 mL/min/1.73m 2 , respectively. Thus, in normal grafts the ROE should exceed 78 per cent. Our data suggest that ROE may be a useful addition to standard scintigraphic parameters in diagnosis of graft obstruction

  11. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    International Nuclear Information System (INIS)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patients were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy

  12. Technetium-99m ceftizoxime kit preparation

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Simone Odilia Fernandes; Siqueira, Cristiano Ferrari; Nelson, David Lee; Cardoso, Valbert Nascimento [Minas Gerais Univ. Federal, Belo Horizonte, MG (Brazil). Faculdade de Farmacia]. E-mail: simone@farmacia.ufmg.br; Martin-Comin, Josep [Bellvitge Univ., Barcelona (Spain)

    2005-10-15

    The aim of this work was to prepare a kit of {sup 99}m Tc-ceftizoxime ({sup 99m} Tc-CFT), with stability and biological activity preserved, able to identify a septic focus (E. coli) in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/m L). After lyophilization, the kit was reconstituted with 1.0 mL of sodium {sup 99m} Tc pertechnetate solution (Na {sup 99m} Tc O{sub 4-}) with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the {sup 99m} Tc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli), the animals were anesthetized and 0.1 mL of {sup 99m} Tc-CFT (37 MBq) was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs) were calculated. The diameters of the inhibition halos for {sup 99}m Tc-CFT were 27.16 {+-} 0.23 and 27.17 {+-} 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 {+-} 0.33 and 29.43 {+-} 0.26, respectively. The results for the biodistribution of {sup 99m} Tc-CFT in infected animals furnished a ratio of 1.97 {+-} 0.31, 2.10 {+-} 0.42 and 2.01 {+-} 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic ({sup 99m} Tc-CFT) by the infectious site during the experiment. The results attest to the viability of producing a kit with {sup 99m} technetium-labeled ceftizoxime for the

  13. Technical problems associated with the production of technetium Tc 99m tin(II) pyrophosphate kits

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Dalton, D.R.

    1981-01-01

    The amount of tin(II) required for adequate reduction, complexation, and stability of technetium Tc 99m pertechnetate in radiopharmaceutical kits, and methods of preventing the loss of tin(II) during formulation of these lyophilized kits are investigated. Tin(II) loss from stannous chloride solutions was studied under several conditions, including room air versus nitrogen atmospheres, during vial filling in a laminar-flow hood with samples frozen on dry ice versus samples at room temperature, during lyophilization, and during storage under refrigerated, ambient, and elevated temperatures. Various amounts of stannous chloride, ranging from 5 to 1000 microgram/ml, were used in formulating sodium pertechnetate Tc 99m kits containing 100 mCi technetium Tc 99m and 0.4 microgram total technetium. Samples were removed at various times; hydrolyzed technetium, pertechnetate, and technetium Tc 99m pyrophosphate were isolated on instant thin-layer chromatography-silica gel and quantified with a scintillation counter. The time necessary to deoxygenate distilled water by nitrogen purging was measured. Several sources of stannous chloride were assayed for tin(II) content. Tin(II) loss occurs rapidly in solution (15% in one hour) unless continuously protected with nitrogen, and during vial filling in a laminar-flow hood unless frozen with dry ice. No substantial loss of tin(II) was detected during lyophilization or during storage of lyophilized product at any of the three temperatures. A minimum of 400 microgram tin(II) was required to provide 90% technetium Tc 99m pyrophosphate at six hours after preparation. Adequate deoxygenation of small quantities (450 ml) of water was accomplished in less than one hour. Some stannous chloride salts were highly oxidized in the dry state, and only high-purity elemental tin wire gave acceptable yields of tin

  14. An investigation into the technical feasibility of cyclotron production of technetium-99m

    International Nuclear Information System (INIS)

    Egan, G.F.; Lagunas-Solar, M.C.

    1994-01-01

    The role of technetium-99m in nuclear medicine is well established with 80 per cent to 90 per cent of all nuclear medicine studies utilising this isotope. Technetium-99m is currently produced from nuclear reactors via production of the parent radionuclide molybdenum-99. The reactor production of 99m Tc has both significant financial and environmental costs, with unresolved problems in the areas of radioactive waste disposal and reactor decommissioning. Recent scientific publications have indicated that medical quality 99m Tc may be produced using cyclotrons without having the associated problems of waste disposal and decommissioning. Further scientific research is now required to demonstrate the feasibility of this cyclotron production technique. A collaboration between the Cyclotron and PET Centre, Austin Hospital, the National Medical Cyclotron, ANSTO, Sydney, and the Crocker Nuclear Laboratory, University of California, Davis, USA has been proposed. The general objective of the proposed collaboration is to acquire additional scientific data to evaluate the 99m Tc cyclotron production method and to determine the feasibility of cyclotron technology for Australian nuclear medicine. 16 refs., 2 tabs

  15. Method of preparation of technetium-99m labelled radio-diagnostic agents and a stable non radio-active carrier

    International Nuclear Information System (INIS)

    1975-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents is described by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung

  16. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  17. 99m Technetium pyrophosphate myocardium scintigraphy. First results

    International Nuclear Information System (INIS)

    Toussaint, Paul.

    1976-01-01

    99m technetium pyrophosphate myocardium scintigraphy is a very recent examination technique. This work gives the results obtained on 61 patients. As a vector of the isotope, pyrophosphate has the advantage over polyphosphate of a fast bone uptake there it should be stressed that a 90 minute pause is necessary between the intraveinous injection of the isotope and the photographic recording so that the reading is not troubled by the labelled intracardiac blood pool image, an image quality criterion being the estimation of a good costal fixation which in fact appears sooner or later according to the subject. The role of pyrophosphate, chelator of calcium in fixation of the isotope on the myocardium, could be explained by the fast appearance of 'dense bodies', made up of calcium hydroxyapathice crystals, in the mitochondria of myocardium cells having undergone an irreversible necrotic process. The choice of 99 m technetium is based on its ease of use: 6 hour half-life, high-energy pure gamma emission at 140 keV. The fixed image studied under two incidences, front and left anterior oblique, is obtained from mobile images given by the scintillation camera used in connection with a data processing system. Several facts are underlined, explaining the disadvantages, advantages and indications of the method [fr

  18. Clinical usefulness of scintigraphy with 99mTechnetium phosphates in rhabdomyolysis

    International Nuclear Information System (INIS)

    Aizawa, Nobuyuki; Hara, Yoshikuni; Suzuki, Yutaka; Akashi, Tsunehiro; Kamei, Tetsumasa; Uchiyama, Fujio; Mitsui, Tamito; Yamazaki, Yuki.

    1990-01-01

    We performed bone scans with 99m Technetium phosphates in 15 cases of clinically suspected rhabdomyolysis admitted to Chigasaki Tokushukai Hospital. Whole body scans were performed within 5 days from the onset of illness or admission. Accumulation of the radioactivity in the skeletal muscle was revealed in 13 of the 15 cases and the involved muscle groups were visualized vividly. Etiologies of rhabdomyolysis were diverse, ranging from malignant syndrome to sepsis. Myocardial concentration was absent in all of the cases. Renal concentration of the isotope was seen in cases where the degree of rhabdomyolysis was higher and renal impairment was present. We conclude that 99m Technetium phosphate bone scan is useful in clinically suspected rhabdomyolysis as a diagnostic test and as a test to localize and quantitate the muscular involvement. (author)

  19. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P [Wisconsin Univ., Milwaukee (USA). Dept. of Radiology

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  20. Technetium-99m labeled radiodiagnostic agents for liver and bone marrow scanning and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Peacock, F.R.

    1977-01-01

    An improved technetium-99m labeled colloid and method of preparation comprising reducing technetium-99m with stannous oxalate and stabilizing with sodium phytate are described. This radiodiagnostic agent is useful in the scintigraphic examination of the reticuloendothelial system, particularly the liver. In addition, by autoclaving this product with saline, it becomes a superior bone marrow scanning agent

  1. Preparation and evaluation of freeze-dried Mag3 kits for 99m Tc-labelling

    International Nuclear Information System (INIS)

    El-Mohty, A.A.; El-Ghany, E.A.; El-Kolaly, M.T.; Raieh, M.; EL-Bary, A.A.

    1996-01-01

    The freeze-dried Mag 3 kits were designed for both ligand trans chelation and direct labelling techniques. The solution of Sn-Mag 3 was sterilized by 0.22 μU mill pore filtration and dispensed in a laminar flow hood (1 m I / vial) then, the vials were introduced to the lyophilized. The process of lyophilization was continued for 24 hours. At end of the cycle, the vials were closed under nitrogen. The moisture content of the freeze-dried Mag 3 kits was determined and it was found equal to 0.1% also, the losses of tin (II) during the freeze-drying cycle did not exceed 5%. It was found that the Mag 3 freeze-dried kits were sterile, pyrogen free and does not have any unexpected toxicity. The prepared Mag 3 freeze-dried kits have high radiochemical purity > 97% and high stability for more than 8 h after labelling. The biodistribution shows rapid renal excretion at 15 min post injection. 3 figs., 4 tabs

  2. Improved the accuracy of 99mTc-MAG3 plasma clearance method. The problem of the calculated plasma volume and its modification

    International Nuclear Information System (INIS)

    Watanabe, Nami; Komatani, Akio; Yamaguchi, Koichi; Takahashi, Kazuei

    1998-01-01

    The 99m Tc-MAG 3 plasma clearance method (MPC method), reported by Oriuchi et al., is a simple and useful count-based gamma camera method for calculating the 99m Tc-MAG 3 plasma clearance (CL MAG ). However, a discrepancy of CL MAG calculated by MPC method (MPC-CL MAG ) from the tubular extraction rate (TER) calculated by Russell's single-sample clearance determination (Russell-TER) was noted. The calculated plasma volume is assumed to be the cause. Since the plasma volume is reported to have a linear correlation with body surface area, Dissmann's formula was applied to calculate the plasma volume. Then Dissmann's formula was replaced by Ogawa's formula in the MPC method, and the procedure was then called the modified MPC method. The CL MAG were obtained using MPC method, modified MPC method and the TER was obtained Russell's method in 95 patients with urological disorders. Then the MPC-CL MAG and modified MPC-CL MAG were compared with Russell-TER. Comparison of the MPC-CL MAG with the Russell-TER demonstrated a coefficient of correlation of 0.82, but dissociation of the slope of regression lines was found between males and females. The modified MPC-CL MAG improved the coefficient of correlation to 0.92, and diminished the dissociation of the slope of regression lines between males and females. We verified that the dissociation was due to the plasma volume calculated by Ogawa's formula. Ogawa's formula included hematocrit, body weight, body height and different coefficients for gender. The plasma volume calculated by Ogawa's formula were lower in males and higher in females than that calculated by Dissmann's formula. And marked discrepancy in the plasma volume in patients with a body surface area below 0.5 m 2 was observed. So the MPC method might become more accurate by substituting Dissmann's formula for Ogawa's formula resoluting in a method that is applicable to both males and females, children and adults in clinical use. (author)

  3. Preclinical evaluation of neurotensin(8-13) analog radiolabeled with 99mTc: in vitro and in vivo characterization

    International Nuclear Information System (INIS)

    Teodoro, Rodrigo

    2010-01-01

    The radiolabeling of receptor specific biomolecules with 99m Tc using bifunctional chelator agents represents a growing field in Nuclear Medicine, specially, regarding regulatory peptides, such as Neurotensin, which are important in several essential physiological functions, particularly in tumor growth. The aim of the study was the comparative radiolabeling evaluation of the double-stabilized NT(8-13) analog with 99m Tc, via the bifunctional chelating agents 6- hydrazinonicotinamide (HYNIC) and S-acetyl-mercaptoacetyltriglycine (MAG3) in MDA-MB-231 breast cancer cell line. High radiochemical yields (> 97%) and stability toward transchelant agents was observed for both radiolabeled analogs. Also, comparable in vitro behaviour regarding the percentage of plasma protein binding (nearby 22%), metabolic stability, receptor binding affinity (nM range), and internalization/externalization rates were obtained. The greater lipophilicity found for the analog radiolabeled via MAG 3 , reflected in the major differences in biodistribution studies. The in vivo metabolic stability studies suggested that the degradation observed in the later time point (90 min) for the conjugate radiolabeled via HYNIC, leads not only to lower tumor uptake accumulation (0,44±0,02% ID/g), but also to lower tumor-to-non-tumor ratios ( 3 had been confirmed in the present study, a structural re-design aiming the reduction of the high gastrointestinal uptake must be done in order to guarantee the potential applicability of MAG 3 -radio complex. (author)

  4. Sensitivity of technetium-99m-d,1-HMPAO to radiolysis in aqueous solutions

    International Nuclear Information System (INIS)

    Tubergen, K.; Corlija, M.; Volkert, W.A.; Holmes, R.A.

    1991-01-01

    The sensitivity of technetium-99m- (99mTc) d,l-HMPAO to radiolytically induced dissociation in aqueous solutions was investigated. It was found that cobalt-60 (60Co) gamma irradiation of solutions containing 99mTc-d,l-HMPAO with only 1600 cGy reduced the lipophilic chelates' radiochemical purity (RCP) to 50%-60%. The radiolytic sensitivity of 99mTc-meso-HMPAO is significantly lower. The results indicate that radiolytically produced intermediates limit the in vitro stability of 99mTc-d,l-HMPAO

  5. Automation drying unit molybdenum-zirconium gel radioisotope production technetium-99M for nuclear medicine

    International Nuclear Information System (INIS)

    Chakrova, Y.; Khromushin, I.; Medvedeva, Z.; Fettsov, I.

    2014-01-01

    Full text : Since 2001 the Institute of Nuclear Physics of the Republic of Kazakhstan has began production of radiopharmaceutical based on technetium-99m from irradiated reactor WWR-K of natural molybdenum, which allows to obtain a solution of technetium-99m of the required quality and high volume activity. In 2013 an automated system is started, which is unique and urgent task is to develop algorithms and software in Python, as well as the manufacture of certain elements of technological systems for automated production

  6. Extraosseous uptake of sup(99m)technetium methylene diphosphonate: Neuroblastoma or radiation therapy

    International Nuclear Information System (INIS)

    Sty, J.R.; Kun, L.; Casper, J.; Babbitt, D.P.

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of sup(99m)technetium methylene diphosphonate (sup(99m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of sup(99m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor. (orig.) [de

  7. Technetium-99m dextran: a promising new protein-losing enteropathy imaging agent

    International Nuclear Information System (INIS)

    Bhatnagar, A.; Singh, A.K.; Lahoti, D.; Singh, T.; Khanna, C.M.

    1996-01-01

    The purpose of this study was to evaluate technetium-99m dextran ( 99m Tc-Dx; molecular weight 81000) as a prospective protein-losing enteropathy (PLE) imaging agent. Twenty-two patients iwth diseases commonly associated with PLE and 12 healthy control subjects underwent intravenous 99m Tc-Dx scintigraphy. All of the 22 test patients showed significant radiotracer accumulation in the intestines within 3-4 h post injection. The focal, regional or generalised nature of the enteropathy and involvement of the large or small intestine could be identified in most cases. Four of the 12 apparently healthy subjects also showed minimal accumulation in the abdominal area occurring late in the study period. This could have been physiological, related to food habits or due to unsuspected intestinal worms. We attribute the high sensitivity of 99m Tc-Dx to its relatively fast blood (background) clearance. The radiotracer may have several other advantages over 99m Tc-labelled human serum albumin in imaging PLE. (orig.)

  8. Technetium-99m-Sestamibi in the diagnosis of acute chest pain

    International Nuclear Information System (INIS)

    Gilleece, T.; Salehi, N.; Better, N.

    1998-01-01

    Full text: A 45-year-old male was admitted to coronary care with a two-day history of recurrent chest pain. Despite maximal medical therapy, pain persisted. Examination and ECG with pain, were normal, suspicion of ischaemia was moderately high but coronary angiography was not immediately available. Technetium-99m-Sestamibi was prepared at the start of the day according to the standard preparation protocol (Du Pont). Coronary Care informed the Nuclear Medicine Department immediately the patient experienced a further episode of chest pain. Technetium-99m-Sestamibi was administered in coronary care, 4.30 minutes after being advised of the onset of further chest pain. Images were acquired 60 minute post-injection; 15 minutes after the patient had been given 200 mL of milk. A triple-headed gamma camera was used to acquire SPECT images over a 1200 arc, 30 frames of 30 seconds using a 64 x 64 matrix. The patient was laying prone with arms raised out of the field of view. Images showed a normal distribution of technetium-99m -Sestamibi throughout the myocardium. Due to ongoing clinical suspicion by the treating physician, coronary angiography was subsequently performed. This showed normal coronary arteries. Medical therapy was ceased and the patient discharged the next day. We concluded that the chest pain at the time of injection was not ischaemic. Previous trials had shown a 95% sensitivity for this method of diagnosing ischaemia. This method permits a novel and simple technique for diagnosing myocardial ischaemia and obviating the need for cardiac catheterization in this group of patients

  9. Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis

    International Nuclear Information System (INIS)

    Riba, A.L.; Downs, J.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1978-01-01

    Technetium-99m stannous pyrophosphate (/sup 99m/Tc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic-valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal, and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +- 5.3 (mean +- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal /sup 99m/Tc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that /sup 99m/Tc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis

  10. Technetium-99m DTPA renal flow studies in Goldblatt hypertension

    International Nuclear Information System (INIS)

    Nally, J.V.; Clarke, H.S.; Windham, J.P.; Grecos, G.P.; Gross, M.L.; Potvin, W.J.

    1985-01-01

    Computer-assisted dynamic renal studies were performed on a group of 14 mongrel dogs before and after the induction of unilateral renal artery stenosis. Ninety-second technetium-99m diethylenetriaminepentaacetic acid ([/sup 99m/Tc]DTPA), 15-min [/sup 99m/Tc]DTPA, and 30-min iodine-131 orthoiodohippurate ([ 131 I]hippuran) time-activity curves were analyzed and correlated with reduction of renal blood flow as measured by electromagnetic flow probe and PAH clearance techniques. For blood flow reductions greater than 33%, the [/sup 99m/Tc]DTPA studies were judged diagnostic of unilateral renal artery stenosis in all cases, whereas the [ 131 I]hippuran time-activity curves were indicative of stenosis in only six of ten studies. Thus, in this model we find the computer-assisted 90-sec [/sup 99m/Tc]DTPA renal flow study to be superior to conventional [ 131 I]hippuran renography in the diagnosis of moderate-to-serve unilateral renal artery stenosis

  11. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Sabine [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany); Rennen, Huub J.; Boerman, Otto C. [Radboud University, Nijmegen Medical Centre, 6500 HB Nijmegen (Netherlands); Baumann, Sabine; Cyr, John E.; Manchanda, Rajesh; Lister-James, John [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany); Corstens, Frans C. [Radboud University, Nijmegen Medical Centre, 6500 HB Nijmegen (Netherlands); Dinkelborg, Ludger M. [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany)], E-mail: sabine.krause@bayerhealthcare.com

    2007-11-15

    Background: The technetium 99 m ({sup 99m}Tc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [{sup 99m}Tc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [{sup 99m}Tc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [{sup 99m}Tc]P483H images were equivalent to those obtained with {sup 111}In ex vivo labeled leukocytes. However, there was physiologic accumulation of radioactivity in the body that could hamper interpretation of the images. In this study, the potential of [{sup 99m}Tc]P1827DS for infection imaging was assessed in comparison with [{sup 99m}Tc]P483H and the well-described imaging agent [{sup 99m}Tc] hydrazinonicotinamide (HYNIC)-interleukin 8 (IL-8). Methods: The binding of [{sup 99m}Tc]P1827DS to human blood cell was studied in vitro. A rabbit Escherichia coli infection model was used to perform the biodistribution and imaging studies with [{sup 99m}Tc]P1827DS, [{sup 99m}Tc]P483H and [{sup 99m}Tc]HYNIC-IL-8. Results: [{sup 99m}Tc]P1827DS binds to leukocytes but not to erythrocytes. The leukocyte binding was not saturable up to an investigated concentration of 10 {mu}M. The accumulation of [{sup 99m}Tc]P1827/DS at the infection site strongly depends on the P1827/DS ratio and was optimal at a molar ratio of 10:1. [{sup 99m}Tc]P1827DS shows improved biodistribution over [{sup 99m}Tc]P483H with similar uptake at the infection site. Abscess uptake of [{sup 99m}Tc]HYNIC-IL-8 was approximately three times higher than that of [{sup 99m}Tc]P1827DS. [{sup 99m}Tc]HYNIC-IL-8 showed high accumulation in the kidneys, whereas [{sup 99m}Tc]P1827DS showed high lung uptake and slightly higher accumulation in the liver and spleen. Conclusion: [{sup 99m}Tc]P1827DS is a potential new inflammation imaging agent, which clearly visualized the abscess in the rabbit E. coli infection model and showed improved biodistribution compared to [{sup 99m}Tc]P483H. However, the infection uptake and biodistribution of

  12. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8

    International Nuclear Information System (INIS)

    Krause, Sabine; Rennen, Huub J.; Boerman, Otto C.; Baumann, Sabine; Cyr, John E.; Manchanda, Rajesh; Lister-James, John; Corstens, Frans C.; Dinkelborg, Ludger M.

    2007-01-01

    Background: The technetium 99 m ( 99m Tc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [ 99m Tc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [ 99m Tc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [ 99m Tc]P483H images were equivalent to those obtained with 111 In ex vivo labeled leukocytes. However, there was physiologic accumulation of radioactivity in the body that could hamper interpretation of the images. In this study, the potential of [ 99m Tc]P1827DS for infection imaging was assessed in comparison with [ 99m Tc]P483H and the well-described imaging agent [ 99m Tc] hydrazinonicotinamide (HYNIC)-interleukin 8 (IL-8). Methods: The binding of [ 99m Tc]P1827DS to human blood cell was studied in vitro. A rabbit Escherichia coli infection model was used to perform the biodistribution and imaging studies with [ 99m Tc]P1827DS, [ 99m Tc]P483H and [ 99m Tc]HYNIC-IL-8. Results: [ 99m Tc]P1827DS binds to leukocytes but not to erythrocytes. The leukocyte binding was not saturable up to an investigated concentration of 10 μM. The accumulation of [ 99m Tc]P1827/DS at the infection site strongly depends on the P1827/DS ratio and was optimal at a molar ratio of 10:1. [ 99m Tc]P1827DS shows improved biodistribution over [ 99m Tc]P483H with similar uptake at the infection site. Abscess uptake of [ 99m Tc]HYNIC-IL-8 was approximately three times higher than that of [ 99m Tc]P1827DS. [ 99m Tc]HYNIC-IL-8 showed high accumulation in the kidneys, whereas [ 99m Tc]P1827DS showed high lung uptake and slightly higher accumulation in the liver and spleen. Conclusion: [ 99m Tc]P1827DS is a potential new inflammation imaging agent, which clearly visualized the abscess in the rabbit E. coli infection model and showed improved biodistribution compared to [ 99m Tc]P483H. However, the infection uptake and biodistribution of [ 99m Tc]P1827DS is not superior to that of [ 99m Tc]HYNIC-IL-8 in this animal model

  13. Uptake and localization of sup(99m)technetium-methylene-diphosphonate in bone

    International Nuclear Information System (INIS)

    Savelkoul, T.J.F.

    1984-01-01

    The author investigated the uptake and localization of 99m-technetium-methylene-diphosphonate (99m-Tc-MDP) in bone, to develop a sensitive mean for the detection of early osseous disease. In an electrolysis procedure without the presence of contaminating reductants a 99m-Tc-MDP complex is formed with clear bone-seeking properties. The scans performed in experimental animals are comparable in quality with 99m-Tc(Sn)-MDP scans. The uptake of 99m-Tc-MDP is faster and higher than the uptake of reduced hydrolyzed 99m-Tc. Uptake of 99m-Tc(Sn)-MDP in bone can only take place after decomposition of the complex. As 99m-Tc-MDP is taken up as a unit, this may be a better agent to evaluate the osteoblastic activity in the skeleton. (Auth./R.B.)

  14. Kit development for labelling erythrocytes or leukocytes with technetium-99m in vitro

    International Nuclear Information System (INIS)

    Wang Xuebin; Han Quansheng; Wang Jingcheng; Mi Hongzhi

    1996-01-01

    This study developed a modified pre tinning method for labeling erythrocytes with technetium-99m in vitro using a kit which contains stannous chloride stabilized with geneticist acid (GA) in lyophilized form. This GA-kit a sterile closed system that does not require centrifugation,washing and separation of the RBCs. The kit is simple to use and labeling takes ∼ 30 min with a typical labeling efficiency of 97.3% ± 1.2% for 60 determinations. Imaging studies were performed in rabbit using GA-kit in vitro labeling procedure and PYP-kit in vivo labeling. It shows that the heart-to-background ratio with GA in vitro labeling were significantly higher than with in vivo labeling. Leukocytes labeling with technetium-99m using the same GA kit also was studied. The labeling efficiency was 20 ∼ 41%. Thus, the GA kit is versatile and cost-effective. (author). 21 refs., 5 figs., 2 tabs

  15. Labeling of thymine with 99m technetium: a suggestion of a chemical model

    International Nuclear Information System (INIS)

    Gutfilen, Bianca; Silva, Claudia Ribeiro da; Bernardo Filho, Mario; Ribeiro, Barbara Luzia Almeida; Mattos, Maura Ferreira

    1996-01-01

    Successful targeting of diagnose but also to stage cancer. It has been shown that certain tumor cells are permeable to low level of exogenous adenosine-diphosphate and adenosine-triphosphate nucleotides, that are incorporated into intracellular pools. We present the labeling of a nucleotide precursor, a base, thymine technetium-99m ( 99m Tc). (author)

  16. Labeling of Tannic Acid with Technetium-99m for Diagnosis of Stomach Ulcer

    OpenAIRE

    Ibrahim, I. T.; El-Tawoosy, M.; Talaat, H. M.

    2011-01-01

    Tannic acid is a polyphenolic compound that could be labeled with technetium-99m. To produce about 90% yield of  99mTc-tannic acid in acidic media (pH), the conditions required were 150  g tin chloride, 30 min reaction time, and 200  g of the substrate. 99mTc-tannic was stable for 6 h. Oral biodistribution of 99mTc-tannic showed that it concentrated in the stomach ulcer to reach about 50% of the total injected dose at 1 h after orall administration. This concentration of 99mTc-tannic in s...

  17. Positive thyroid cancer scintigraphy using technetium-99m methoxyisobutylisonitrile

    International Nuclear Information System (INIS)

    Nemec, J.; Nyvltova, O.; Blazek, T.; Vlcek, P.; Racek, P.; Novak, Z.; Preiningerova, M.; Hubackova, M.; Krizova, M.; Zimak, J.; Bilek, R.

    1996-01-01

    The aim of the study was to evaluate the possibility of detecting thyroid cancer recurrences without the need for withdrawal of thyroid suppressive treatment. Upper-body or whole-body scintigraphy was performed in a group of 200 patients evaluated for differentiated thyroid cancers in 1993 and 1994 using technetium-99m sestamibi. Scans were performed 20-30 min following i.v. administration of 500 MBq of 99m Tc-methoxyisobutylisonitrile (MIBI). Bone and lung metastases were detected with very high sensitivity and specificity, with a very high predictive value of negative results and a somewhat lower predictive value of positive results. The sensitivity and specificity of findings in the neck were lower but the predictive value of negative results was high. Whole-body scans with 99m Tc-MIBI are a useful tool in the follow-up of patients with differentiated thyroid cancer, for the detection of distant metastatic lesions. (orig.)

  18. Detection of unstable angina by /sup 99m/technetium pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Abdulla, A.M.; Canedo, M.I.; Cortez, B.C.; McGinnis, K.D.; Wilhelm, S.K.

    1976-01-01

    /sup 99m/Technetium stannous pyrophosphate has been shown to accumulate in acutely infarcted myocardium. To determine if the isotope is also taken up by severely ischemic, but not necrotic myocardium, we performed myocardial scintigraphic studies in 17 patients with chest pains. Seven of the patients satisfied conventional clinical, electrocardiographic, and laboratory criteria for the diagnosis of unstable angina and showed no electrocardiographic or enzymatic evidence of myocardial necrosis. Five of these seven patients with unstable angina demonstrated abnormal localized patterns, and one showed a borderline picture. Myocardial scintiscans were normal in all of a control group of ten patients with stable angina. Thus, scanning with /sup 99m/technetium stannous pyrophosphate is shown to be of value in the objective demonstration of myocardial abnormality in unstable angina

  19. Clinical usefulness of scintigraphy with sup 99m Technetium phosphates in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, Nobuyuki; Hara, Yoshikuni (Shonan Kamakura Hospital, Kanagawa (Japan)); Suzuki, Yutaka; Akashi, Tsunehiro; Kamei, Tetsumasa; Uchiyama, Fujio; Mitsui, Tamito; Yamazaki, Yuki

    1990-08-01

    We performed bone scans with {sup 99m}Technetium phosphates in 15 cases of clinically suspected rhabdomyolysis admitted to Chigasaki Tokushukai Hospital. Whole body scans were performed within 5 days from the onset of illness or admission. Accumulation of the radioactivity in the skeletal muscle was revealed in 13 of the 15 cases and the involved muscle groups were visualized vividly. Etiologies of rhabdomyolysis were diverse, ranging from malignant syndrome to sepsis. Myocardial concentration was absent in all of the cases. Renal concentration of the isotope was seen in cases where the degree of rhabdomyolysis was higher and renal impairment was present. We conclude that {sup 99m}Technetium phosphate bone scan is useful in clinically suspected rhabdomyolysis as a diagnostic test and as a test to localize and quantitate the muscular involvement. (author).

  20. The use of technetium-99m-DTPA in the diagnosis of tuberculous meningitis

    International Nuclear Information System (INIS)

    Von Wenzel, K.S.

    1988-03-01

    As 82 Br is not available locally in South West Africa on a daily basis a technetium preparation, 99m Tc-DTPA, was used in the diagnosis of patients with tuberculous meningitis. The 99m Tc-DTPA partition test was compared with the 82 Br partition test on 22 trial subjects. The trial subjects varied in age (0,8-57 years), sex and race. There were 7 patients diagnosed by the clinicians as having tuberculous meningitis. All patients were placed on anti-tuberculous meningitis treatment and all, except 2, one of whom regressed and 1 who died 7 days later, improved slowly. The 9 patients with viral meningitis received no antibiotics and recovered rapidly on symptomatic treatment only. With all 5 the septic meningitis cases, the organism was identified and there was thus no diagnostic uncertainty. One normal control subject was also examined. It would appear from the results that both 82 Br, as well as 99m Tc-DTPA, cross the blood-brain barrier to a greater extent in the case of tuberculous meningitis, compared to viral meningitis. Although the accuracy of the 82 Br test, if a critical ratio value of 1,3 was chosen, is 90,6% compared to 86,9% of the 99m Tc-DTPA partition test if a critical ratio value of 3 was chosen, there are still advantages to the use of the technetium preparation. These include the availability, cost and lower radiation dose per MBq as well as the possibility of brain imaging. 10 figs., 58 refs., 9 tabs

  1. Extraosseous uptake of /sup 99/sup(m)technetium methylene diphosphonate. Neuroblastoma or radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Sty, J R; Kun, L; Casper, J; Babbitt, D P

    1980-01-01

    A child with a ganglioneuroblastoma and tumor uptake of /sup 99/sup(m)technetium methylene diphosphate (/sup 99/sup(m)Tc-MDP) is presented. After surgical removal of an encapsulated tumor and radiation therapy, an interval bone scan demonstrated the same presurgical abnormality. Awareness of abnormal uptake of /sup 99/sup(m)Tc-MDP in irradiated renal tissue prevents interpreting radiation nephritis as recurrent tumor.

  2. Technetium {sup 99m}Tc Pertechnetate Brain Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi [Capital Army Hospital, ROKA, Seoul (Korea, Republic of); Rhee, Chong Heon; Koh, Chang Soon [Radiological Research Institute, Seoul (Korea, Republic of)

    1968-03-15

    Technetium {sup 99}mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or {sup 131}I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced {sup 99}mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  3. Radioimmunoscintigraphy with technetium-99m labelled monoclonal antibody, 1A3, in colorectal cancer

    International Nuclear Information System (INIS)

    Granowska, M.; Britton, K.E.; Mather, S.J.; Morris, G.; Ellison, D.; Soobramoney, S.; Talbot, I.C.; Northover, J.M.A.

    1993-01-01

    This study of radioimmunoscintigraphy (RIS) was primarily undertaken to determine how the imaging results related to surgical findings. Technetium-99m radiolabelled 1A3, a monoclonal antibody against a columnar cell surface antigen, was used. No adverse effects or thyroid uptake was observed in 127 studies. The 85 primary colorectal cancers were all image positive. In the assessment of recurrent tumour in the abdomen or pelvis, the accuracy was 33/35 (94%), including true-positive findings in some whose serum carcinoembryonic antigen was normal. There was a positive predictive value for abdominal or pelvic recurrence of 92% and a negative predictive value of 100%, at a prevalence of 66%. In those patients whose liver was able to be evaluated, the accuracy was 72/79 (91%). There was a positive predictive value for liver metastases of 88% and a negative predictive value of 93%, at a prelavence of 32%. The simple procedure for labelling antibody with 99m Tc and its ready availability allow a completed report to be given within 24 h of the request. (orig.)

  4. Sup(99m) Technetium - labeled red blood cells 'in vitro'

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Souza Moura, I.N. de; Boasquevisque, E.M.

    1983-01-01

    A simple technique for the preparation of sup(99m) Tc labeled red blood cells using a comercial kit is described. To each 3ml of plain blood with anti-coagulant was added 1ml of solution of commercial kit with 6.8 μg of stannous chloride. This mixture was incubated in water bath, at 37 0 C, for 60 minutes. Then technetium-99m was added and the mixture was left for another ten minutes, in water bath, at 37 0 C. Under these conditions there was the best labeling of the red blood cells. Similar results were obtained with a solution of stannous chloride prepared freshly. The labeling is strong for 6.8 μg stannous chloride because the labeling was not removed by the several washes of the red blood cells or by the left in water bath. (Author) [pt

  5. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    Science.gov (United States)

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  6. Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin

    International Nuclear Information System (INIS)

    Thrall, J.H.; Freitas, J.E.; Swanson, D.; Rogers, W.L.; Clare, J.M.; Brown, M.L.; Pitt, B.

    1978-01-01

    Technetium-99m red blood cells (Tc-RBC) labeled by an in vivo technique were compared with two preparations of Tc-99m human serum albumin (HSA) for cardiac blood-pool imaging. Relative distribution of the tracers was analyzed on end-diastolic frames of gated blood-pool studies and on whole-body (head to mid-thigh) anterior pinhole images. The Tc-RBC demonstrated greater relative percentage localization in the cardiac blood pool, higher target-to-background ratios in the left ventricle, and less liver concentration. For cardiac blood-pool imaging, Tc-RBC labeled by the in vivo approach appears to be superior to the two Tc-HSA preparations studied

  7. Labeling of thymine with {sup 99m} technetium: a suggestion of a chemical model

    Energy Technology Data Exchange (ETDEWEB)

    Gutfilen, Bianca; Silva, Claudia Ribeiro da; Bernardo Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Biologia. Dept. de Biofisica e Biometria; Ribeiro, Barbara Luzia Almeida [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil). Centro de Pesquisa Basica; Mattos, Maura Ferreira [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Quimica

    1996-03-01

    Successful targeting of diagnose but also to stage cancer. It has been shown that certain tumor cells are permeable to low level of exogenous adenosine-diphosphate and adenosine-triphosphate nucleotides, that are incorporated into intracellular pools. We present the labeling of a nucleotide precursor, a base, thymine technetium-99m ({sup 99m} Tc). (author)

  8. Acetylsalicylic acid and labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Adenilson de Souza da [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Dept. de Farmacologia e Psicobiologia; Frydman, Jacques Natan Grinapel; Rocha, Vanessa Camara da; Bernardo-Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2005-10-15

    Acetylsalicylic acid is the drug most used an anti-inflammatory agent and for secondary prevention of thrombotic phenomenon. Drugs can modify the labeling of blood constituents with technetium-99m (99m Tc). The aim of this work was to evaluate the effect of in vitro or in vivo assays with acetylsalicylic acid on the labeling of the blood constituents with 99m Tc. In vitro assay was performed with samples of whole blood from Wistar rats incubated with acetylsalicylic acid (1.0 mg/ml) for one hour before the 99m Tc-labeling process. For in vivo assay, Wistar rats were treated with acetylsalicylic acid (1.5 mg/kg) during one hour, and the whole blood was withdrawn for the 99m Tc-labeling process. Saline was used in control groups. Data showed that the fixation of 99m Tc to the blood constituents was not significantly (p>0.05) modified in in vitro and in vivo assays with acetylsalicylic acid, at least not when the experiments were carried out with the doses normally used in human beings. (author)

  9. Diagnostic usefulness of technetium-99m (V) DMSA scintigraphy in cases of soft tissue tumors; In comparison with that of Ga-67 citrate scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hisataka; Kotoura, Yoshihiko; Hanbara, Harumi; Hosono, Makoto; Yamamuro, Takao; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine)

    1994-05-01

    Technetium-99m (V) DMSA scintigraphy was performed in 76 patients with pathologically confirmed soft tissue diseases. In 56 patients, gallium-67 citrate scintigraphy was performed within two weeks after technetium-99m (V) DMSA scintigraphy. Significant uptake of technetium-99m (V) DMSA was found in all cases of sarcoma, metastatic carcinoma, progressive benignancy (extra-abdominal desmoid etc.) and granulomatous lesions, but was not found in cases of benign, solid tumors in the soft tissue (leiomyoma, neurinoma, lipoma etc.). In conclusion, it is not necessary to treat patients with soft tissue tumors in which technetium-99m (V) DMSA did not accumulate. Therefore, it can be stated that technetium-99m (V) DMSA scintigraphy is useful for the screening of malignant tumors. (author).

  10. Risk analysis applied to the production of generators of Molybdenum-99/Technetium-99m

    International Nuclear Information System (INIS)

    Rodriguez, Daniel; Torres, Antonio; Henriquez, Jorge R.; Soria, Miguel A.; Ayra, Fernando E.

    2017-01-01

    Radionuclide Technetium-99m is the most used today, so that their production is vital to the branches of health and the economy of any country. Cuba currently producing generators for obtaining this radionuclide, and it is produce at the Center of Isotopes. Risk assessments of radiological hazard installations are a regulatory requirement in Cuba. Although there are several qualitative or quantitative methods to perform these studies, the existence of basis risk starting and analysis codes and simplicity of use has been privileged the risk matrix as a preferred semi-quantitative method. The investigation presents the application, for the first time, of this method on a complex installation with radiological hazard in Cuba. Using the SECURE - MR Ver. 2.0 code detailed risk analysis of the practice carried out, resulting in three accidental sequences with high-risk level and determining the importance of reducers and barriers related with human factors associated to sufficiency and personnel training. Among the derived applications are reported the novelties analysis capabilities and possibilities of risk monitoring. The risk model developed for the production process of generators of Molybdenum-99/Technetium-99m joined with capabilities review, analysis and documentation provided by the tool, allow obtaining a completely and coherent document with the model, which constitutes a valuable basis for understanding the safety of the installation knowledge. (author)

  11. Risk analysis applied to the production of generators of Molybdenum-99/Technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, Daniel; Torres, Antonio; Henriquez, Jorge R.; Soria, Miguel A.; Ayra, Fernando E., E-mail: danivd1188@gmail.com, E-mail: rjorge@ufpe.br, E-mail: masguevara@centis.edu.cu, E-mail: feayra@centis.cu [Universidade Federal de Pernambuco (DEMEC/UFPE), Recife, PE (Brazil). Departamento de Engenharia Mecanica; Departamento de Ingenieria Nuclear, Instituto Superior de Tecnologias y Ciencias Aplicadas (DIN/InSTEC), La Habana (Cuba); Departamento de Proteccion Radiologica, Centro de Isotopos (DPR/CENTIS), La Habana (Cuba)

    2017-11-01

    Radionuclide Technetium-99m is the most used today, so that their production is vital to the branches of health and the economy of any country. Cuba currently producing generators for obtaining this radionuclide, and it is produce at the Center of Isotopes. Risk assessments of radiological hazard installations are a regulatory requirement in Cuba. Although there are several qualitative or quantitative methods to perform these studies, the existence of basis risk starting and analysis codes and simplicity of use has been privileged the risk matrix as a preferred semi-quantitative method. The investigation presents the application, for the first time, of this method on a complex installation with radiological hazard in Cuba. Using the SECURE - MR Ver. 2.0 code detailed risk analysis of the practice carried out, resulting in three accidental sequences with high-risk level and determining the importance of reducers and barriers related with human factors associated to sufficiency and personnel training. Among the derived applications are reported the novelties analysis capabilities and possibilities of risk monitoring. The risk model developed for the production process of generators of Molybdenum-99/Technetium-99m joined with capabilities review, analysis and documentation provided by the tool, allow obtaining a completely and coherent document with the model, which constitutes a valuable basis for understanding the safety of the installation knowledge. (author)

  12. Lymphoma imaging with a new technetium-99m labelled antibody, LL2

    International Nuclear Information System (INIS)

    Murthy, S.; Sharkey, R.M.; Goldenberg, D.M.; Lee, R.E.; Pinsky, C.M.; Hansen, H.J.; Burger, K.; Swayne, L.C.

    1992-01-01

    The lesion detection capability of a new technetium-99m labelled B-cell lymphoma monoclonal antibody (MoAb) imaging agent, LL2, was evaluated in 8 patients with non-Hodgkin's lymphoma and 1 patient with chronic lymphocytic leukaemia. The MoAb kit consists of a 1-vial, 1-mg Fab' form of LL2 ready for instant labelling with technetium. The patients were injected with ∝925 MBq (25 mCi) of 99m Tc-LL2 Fab' (1 mg), and planar and single photon emission tomography (SPET) studies were performed at 3-4 h post injection and at 24 h. There was no evidence of thyroid or stomach activity up to 24 h. Uniform splenic uptake was seen in all patients. Two non-lymphoma patients were also administered with the same agent and demonstrated a similar splenic distribution; therefore, splenic targeting was not scored as tumour-specific. A total of 29 from 48 tumour sites were detected by scintigraphy, including tumours of various grades and histological types. Excluding 1 patient who had a large tumour burden of over 500 g, 29 of 33 lesions were detected. One patient was free of disease at the time of the study and had a negative scan. Another patient showed excellent targeting of gallium-negative sites in the liver and bone. The bone involvement was not known prior to the antibody study and was subsequently confirmed by a bone scan. Additional sites of MoAb localization could not be followed in this group, since most patients went on to radioimmunotherapy immediately following the 99m Tc-LL2 study. However, these initial results suggest that this new 99m Tc-labelled antibody imaging kit should be further investigated for its potential role in the staging and follow-up of lymphoma patients. (orig.)

  13. Effect of technetium Tc 99m pertechnetate on bacterial survival in solution

    International Nuclear Information System (INIS)

    Stathis, V.J.; Miller, C.M.; Doerr, G.F.; Coffey, J.L.; Hladik, W.B.

    1983-01-01

    Survival of Staphylococcus epidermidis (10(2) organisms/ml) in solutions containing various levels of radioactivity was assessed. Six test preparations contained nonbacteriostatic 0.9% sodium chloride solution; four of these contained technetium Tc 99m pertechnetate (99mTcO-4) in various quantities (80, 250, 500, and 750 mCi). A fifth contained technetium that had decayed to an essentially nonradioactive form, and a sixth contained 0.9% sodium chloride solution only. Each of the six 20-ml solutions was inoculated with 2 ml of single-strength trypticase soy broth (TSB) containing 10(3) organisms/ml. At various times up to 12 hours after inoculation, 1-ml aliquots of each test solution were withdrawn and passed through 0.22-micron filters, thereby preventing further irradiation of the filtered organisms. The filters were incubated in single-strength TSB at 37 degrees C, and samples were examined for turbidity at 24, 48, and 72 hours. After 24 hours, 25 of the 36 sample tubes showed turbidity; after 48 hours, the turbid samples totaled 28. Bacteria in the two nonradioactive solutions remained viable throughout the 12-hour sampling period. Accumulated doses of radiation obtained in the 250-, 500-, and 750-mCi samples inhibited bacterial growth. To be a valid quality-control measure, sterility monitoring of prepared radiopharmaceutical dosage forms may need to be performed concurrently with their preparation

  14. Biodistribution of 99m technetium labeled creatinine in healthy rats

    International Nuclear Information System (INIS)

    Yilmaz, O.; Soylu, A.; Kavukcu, S.; Lambrecht, F. Yurt; Durkan, K.

    2007-01-01

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with 99m technetium ( 99m Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 ± 2% under optimum conditions (pH 7 and 100 μg stannous chloride). Rats (N 12) were injected intravenously with 99m Tc creatinine and their blood and visceral organs were evaluated for 99m Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of 99m Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  15. TESTING GUIDELINES FOR TECHNETIUM-99 ADSORPTION ON ACTIVATED CARBON

    International Nuclear Information System (INIS)

    Byrnes, M.E.

    2010-01-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs) will

  16. TESTING GUIDELINES FOR TECHNETIUM-99 ABSORPTION ON ACTIVATED CARBON

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2010-09-08

    CH2M HILL Plateau Remediation Company (CHPRC) is currently evaluating the potential use of activated carbon adsorption for removing technetium-99 from groundwater as a treatment method for the Hanford Site's 200 West Area groundwater pump-and-treat system. The current pump-and-treat system design will include an ion-exchange (IX) system for selective removal of technetium-99 from selected wells prior to subsequent treatment of the water in the central treatment system. The IX resin selected for technetium-99 removal is Purolite A530E. The resin service life is estimated to be approximately 66.85 days at the design technetium-99 loading rate, and the spent resin must be replaced because it cannot be regenerated. The resulting operating costs associated with resin replacement every 66.85 days are estimated at $0.98 million/year. Activated carbon pre-treatment is being evaluated as a potential cost-saving measure to offset the high operating costs associated with frequent IX resin replacement. This document is preceded by the Literature Survey of Technetium-99 Groundwater Pre-Treatment Option Using Granular Activated Carbon (SGW-43928), which identified and evaluated prior research related to technetium-99 adsorption on activated carbon. The survey also evaluated potential operating considerations for this treatment approach for the 200 West Area. The preliminary conclusions of the literature survey are as follows: (1) Activated carbon can be used to selectively remove technetium-99 from contaminated groundwater. (2) Technetium-99 adsorption onto activated carbon is expected to vary significantly based on carbon types and operating conditions. For the treatment approach to be viable at the Hanford Site, activated carbon must be capable of achieving a designated minimum technetium-99 uptake. (3) Certain radionuclides known to be present in 200 West Area groundwater are also likely to adsorb onto activated carbon. (4) Organic solvent contaminants of concern (COCs

  17. Radiation hazards from horses undergoing scintigraphy using technetium -{sup 99m}

    Energy Technology Data Exchange (ETDEWEB)

    Whitelock, R.G. [Royal Veterinary College, Hatfield (United Kingdom)

    1997-01-01

    This paper quantifies the extent of the radiation hazard to personnel from horses undergoing scintigraphy using technetium{sup 99m} methylene diphosphonate ({sup 99m}Tc{sup m}-MDP). From the data produced it is possible to derive safe working protocols which are comfortably within the legislated limits for whole body doses as set out in the Ionising Radiations Regulations 1985. Measurements were made of the surface and environmental activities which result from individuals undergoing scintigraphic evaluation and also from urine contaminated bedding. The use of both high and low activities in the assessment of the radiation hazard to personnel and owners is considered. (author).

  18. Obtention of scintillography images by low density lipoproteins labelled with technetium 99

    International Nuclear Information System (INIS)

    Silva, S.; Coelho, I.; Zanardo, E.; Pileggi, F.; Meneguethi, C.; Maranhao, R.C.

    1992-01-01

    The low density lipoproteins carry the most part of the cholesterol in the blood plasma. These lipoproteins are labelled with technetium-99-m and have been used for obtaining images in nuclear medicine. The introduction of this technique is presented, aiming futures clinical uses. Scintillographic images are obtained 25 minutes and 24 hours after the injection of 3 m Ci of low density lipoproteins - technetium-99 m in rabbits. (C.G.C.)

  19. Quantification of ocular inflammation with technetium-99m glucoheptonate

    International Nuclear Information System (INIS)

    Roizenblatt, J.; Caldeira, J.A.F.; Buchpiguel, C.A.; Meneguetti, J.C.; Camargo, E.E.; Sao Paulo Univ., SP

    1991-01-01

    Histological and morphometric evaluation of ocular inflammation is difficult, particularly when there is extensive ocular involvement with abscess formation and necrosis. A quantitative imaging procedure applicable to humans would be important clinically. To establish such a procedure, turpentine-induced ocular inflammation was obtained by subconjunctival injection in the right eye of 55 rabbits. The left eye was used as control and injected with a volume of saline equal to the volume of turpentine in the right eye. Volumes of turpentine or saline were 0.02, 0.04, 0.06, 0.2 and 0.6 ml, and the rabbits were divided into groups 1-5, according to these volumes. Imaging was performed 48 h after turpentine injection and 6 h after intravenous injection of 10 mCi of technetium 99m glucoheptonate ( 99m Tc-GH). An inflammatory reaction index (IRI), defined as the ratio of counts of the right eye divided by counts of the left eye, was used. IRIs were proportional to the degree of inflammation and allowed the distinction of 3 subgroups: One represented by group 4, one by group 5 and one by groups 1, 2 and 3. This method of quantification of ocular inflammatory processes using 99m Tc-GH is original, rapid, non-invasive, reproducible and safe, although unable to differentiate inflammatory processes caused by doses of turpentine which are very small and close to each other. It is conceivable that its application to humans will bring new insight into the ocular inflammatory process and response to therapy. (orig.)

  20. Exposure to fingers while handling a solvent extraction-type technetium-99m generator

    International Nuclear Information System (INIS)

    Kini, K.S.; Venkateswaran, T.V.

    1985-01-01

    Technetium-99m-labeled compounds are routinely used for various diagnostic procedures in nuclear medicine. In India, most of the nuclear medicine centers use /sup 99m/Tc obtained from a solvent extraction-type generator. As a result of the long procedure involved in the separation of /sup 99m/Tc from /sup 99m/Mo in this type of generator compared to the elution of /sup 99m/Tc from a column-type generator, like likelihood of exposure to fingers of technicians is high. The measurement of radiation exposure was done on 16 workers at seven major nuclear medicine centers in India. With the existing work load, the exposures to the fingers were found to be within the permissible limits

  1. Contribution of technetium 99m-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis

    International Nuclear Information System (INIS)

    Capdepont, M.-T.

    1976-01-01

    This work examines the contribution of technetium 99m(sup(99m)Tc)-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis and attempts to define its importance in the diagnosis of lesions and their subsequent supervision in patients under treatment. 5 to 15 millicuries of sup(99m)Tc-labelled pyrophosphates are injected intraveinously. Bone uptake is strong and durable; 1.3% of the injected activity is found in the blood by the fifth hour. The skeleton may be explored: - either one segment at a tome with a scintillation camera, - or all at once and more quickly with a whole-body device taking front and black exposures. Bone scintigraphy appears as a basic technique in the study of infectious spondylodiscitis. Moreover the use of increasingly efficient equipment, the quantification of results and perhaps the development of new tracers augur well for a technique which is already acknowledged to be of fundamental interest [fr

  2. Technetium-99m sestamibi: an indicator of breast cancer invasiveness

    Energy Technology Data Exchange (ETDEWEB)

    Scopinaro, F. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Schillaci, O. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Scarpini, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Mingazzini, P.L. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Di Macio, L. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Banci, M. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Danieli, R. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy)); Zerilli, M. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Limiti, M.R. (1st Inst. of Surgery, Univ. ' La Sapienza' , Rome (Italy)); Centi Colella, A. (Section of Nuclear Medicine, Dept. of Experimental Medicine, Univ. ' La Sapienza' , Rome (Italy))

    1994-09-01

    As recently shown, angiogenesis is the most reliable marker of breast cancer invasiveness. Unfortunately it must be assessed by immunohistochemistry on tissue specimens. We have used technetium-99m sestamibi, a marker of regional blood flow in other organs that often but not always images breast cancer, to assess the invasiveness of this tumour. Nineteen patients, ten with nodal metastases and nine without any metastases, were studied with [sup 99m]Tc-sestamibi scintigraphy before operation. Angiogenesis was quantitatively assessed by immunohistochemical staining of endothelia for factor VIII. All the node-positive (N+) patients at surgical revesion showed a positive [sup 99m]Tc-sestamibi scan of the primary tumour and all the N-patients were negative. Nine out of ten N+ and sestamibi-positive tumours showed more than 135 microvessels/mm[sup 2] and one showed 99 microvessels/mm[sup 2]; by contrast there were 71.6[+-]12.1 microvessels/mm[sup 2] in the nine N- and sestamibi-negative tumours. Our study suggests that [sup 99m]Tc-sestamibi is a marker of breast cancer invasiveness: its uptake is related to angiogenesis and, possibly, to oxidative metabolism of the tumour. (orig.)

  3. Environmental behavior of technetium-99

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1982-12-01

    This report presents a review of the literature on technetium-99. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is presented, including its behavior in the bodies of animals and humans. The primary sources of Tc-99 in the environment are fallout from atomic detonations and releases from nuclear fuel reprocessing plants. The environmental behavior of technetium-99 has been studied predominantly with respect to movement in soil and accumulation in plants. There is a surprising scarcity of data on behavior of Tc-99 in the atmosphere and in aquatic systems. Additional work needs to be conducted in these two areas to determine behavior and to acquire baseline concentration data. Much of the soil work has produced contradictory results. In-depth studies of holdup mechanisms for Tc-99 in both geological repositories and soil need to be conducted. Since plants represent a potential bioaccumulation of Tc-99, plant uptake studies of Tc-99 under field conditions also need to be done

  4. Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid (/sup 99m/Tc HIDA): a new radiopharmaceutical for hepatobiliary imaging studies

    International Nuclear Information System (INIS)

    Ryan, J.; Cooper, M.; Loberg, M.; Harvey, E.; Sikorski, S.

    1977-01-01

    An easily formulated, stable kit preparation of technetium-99m HIDA, suitable for use in humans, was developed and tested in mice and dogs. The tracer was cleared rapidly from the blood and excreted predominantly by the liver in both species. In dogs, the hepatobiliary clearance of Tc-99m HIDA was significantly greater than that of C-14 HIDA and Sn-113 HIDA. The LD 50 for HIDA in mice, 168 mg/kg, exceeded the average human dose by a factor of 1000 on a per-weight basis. Blood clearance curves for Tc-99m HIDA in 12 normal subjects were biexponential with half-times of 4.6 +- 1.0 min and 31.5 +- 7.0 min, and cumulative 90-min urine samples contained 14.2 +- 1.8% of the injected dose. Images in normal subjects and nonjaundiced patients showed rapid concentration of tracer by the liver and activity was present within the biliary system in 10 to 20 min. In jaundiced patients, the tracer blood clearance was delayed and urinary excretion increased, but intestinal activity, indicating biliary patency, was imaged in those patients without complete focal obstruction of the common duct. Technetium-99m HIDA is a nontoxic radiopharmaceutical useful for clinical evaluation of hepatobiliary disorders in humans

  5. Biological evaluation of 99m Tc-N-(3-bromo-trimethyl-acetanilide)-iminodiacetic acid (99mTc mebrofenin) as hepatobiliary radiopharmaceutical

    International Nuclear Information System (INIS)

    Hamada, E.S.

    1994-01-01

    Technetium-99 m-N-(3-bromo-2,4,6-trimethyl acetanilide) iminodiacetic acid ( 99m Tc-Mebrofenin) has been described as having optimal properties as hepatobiliary radiopharmaceutical. This paper describes the synthesis, radiopharmaceutical preparation and biological distribution of new labeled compound. The biodistribution study of 99m Tc-Mebrofenin- was carried out in normal mice. The specificity for hepatobiliary excretion blood clearance and cumulative biliary excretion were evaluated in normal and cirrhotic rats. (author). 5 refs, 3 figs, 3 tabs

  6. Technetium-99m pertechnetate - a tracer for radiolabelling antibody for inflammation detection

    International Nuclear Information System (INIS)

    Shaharuddin Mohd; Wan Hamirul Bahrin Wan Kamal; Shahrin A Hamid; Ang Woan Tze; Rosnani Hashim

    1999-01-01

    The polyclonal antibody, Human Immunoglobulin G (HlgG) was reduced by using 2-mercaptoethanol with molar ratio of 1000:1 (i.e. mercaptoethanol:antibody). The reduction of the antibody, was carried out for 30 minutes at room temperature. The reduced antibody was purified by using Sephadex G-25 fine column. The antibody kit for the detection of inflammation was prepared aseptically in Class 1 Laminar Flow cabinet. The kit passed the sterility test. Upon reconstitution of the antibody kit with sodium pertechnetate-99m ( 99m Tc) solution, the labelling efficiency obtained was more than 95%. This preparation was stable up to 24-hour stored at room temperature. Gamma camera scans showed the accumulation of technetium-99m labelled antibody ( 99m Tc-HIgG) at the turpentine-induced inflammation of female Sprague-Dawley rats. This indicated the possibility of using 99m Tc-HIgG for inflammation detection. (author)

  7. Technetium /sup 99m/Tc macroaggregated albumin lung scans. Use in chronic childhood asthma

    International Nuclear Information System (INIS)

    Hyde, J.S.; Koch, D.F.; Isenberg, P.D.; Werner, P.

    1976-01-01

    Serial roentgenograms and technetium /sub 99m/Tc macroaggregated albumin lung scans were done simultaneously in 30 bronchodilator-dependent asthmatic children and young adults during both relative remission and attacks of status asthmaticus. When chest roentgenograms showed air trapping and increased peribronchial vascular markings associated with persistent perfusion defects, the children benefited from further laboratory studies and continuous comprehensive therapy. Serial scans provided information about underperfusion that was not discernible either by roentgenograms or by usual blood gas studies. Also, lung scans are easier to obtain in children with long-standing asthma than are detailed pulmonary tests. In our study, technetium /sup 99m/Tc macroaggregated albumin scans showed persistent regional perfusion defects in 20 children with chronic asthma during relative remission and exacerbations

  8. Technetium-99m in nuclear medicine and radiation protection experience

    International Nuclear Information System (INIS)

    Ninkovic, M. M.; Raicevic, J. J.; Pavlovic, S.; Glisic, R.

    2002-01-01

    The one of the major contributors to personnel exposure whithin nuclear medicine laboratories is primarily now ubiquitous 99 Mo- 99m Tc generators. These generators, first available about more than forthy years ago, are now providing large quantities of 99m Tc radioactive source daily in the most laboratories, both for direct injection, as a per-technetate ion, and through the utilization of the kits for the preparation of dipherent radiopharmaceuticals. The safe and efficient utilization of technetium-99m in nuclear medicine, as other radionuclides, begin with the design, construction and operation of the 'Hot'Laboratory area, where radionuclide are stored and patient doses are prepared. Regardless of the specific physical configuration, suitable facilities need to be provided and good working practices established in order to get these principal objectives: (a) keep radiation exposure to personnel at ALARA levels; (b) prevent contamination of personnel; (c) prevent contamination of measuring instruments (including imaging devices such as gamma cameras and rectilinear scanners), and (d) prevent spread of contamination to places or persons outside the laboratory

  9. Efficient one-step direct labelling of recombinant antibodies with technetium-99m

    International Nuclear Information System (INIS)

    Liberatore, M.; Neri, D.; Neri, G.; Pini, A.; Lurilli, A.P.; Ponzo, F.; Spampinato, G.; Padula, F.; Pala, A.; Colella, A.C.

    1995-01-01

    High-affinity bacterially expressed antibody fragments can nowadays be cloned from established hybridomas or, more conveniently, isolated directly from antibody libraries displayed on filamentous phage. Such antibodies can be tagged with C-terminal peptide tags containing one cysteine residue, which represents a convenient functionalisation site for a number of applications, including technetium-99m labelling. Here we describe a simple one-step method for 99m Tc labelling of cysteine-tagged recombinant antibodies with more than 50% radionuclide incorporation. The labelled antibodies displayed full retention of immuoreactivity and good stability. (orig.)

  10. Efficient one-step direct labelling of recombinant antibodies with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Liberatore, M. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Neri, D. [Cambridge Centre for Protein Engineering - MRC Centre (United Kingdom); Neri, G. [Dipartimento di Biologia Molecolare, Universita di Siena (Italy); Pini, A. [Dipartimento di Biologia Molecolare, Universita di Siena (Italy); Lurilli, A.P. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Ponzo, F. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy); Spampinato, G. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Padula, F. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Pala, A. [Laboratorio di Biochimica degli Ormoni Sessuali, Il Instituto di Clinica Ostetrica e Ginecologica, Universita di Roma `La Sapienza` (Italy); Colella, A.C. [Dipartimento di Medicina Sperimentale, Sezione di Medicina Nucleare, Policlinico Umberto I, Universita di Roma `La Sapienza` (Italy)

    1995-11-01

    High-affinity bacterially expressed antibody fragments can nowadays be cloned from established hybridomas or, more conveniently, isolated directly from antibody libraries displayed on filamentous phage. Such antibodies can be tagged with C-terminal peptide tags containing one cysteine residue, which represents a convenient functionalisation site for a number of applications, including technetium-99m labelling. Here we describe a simple one-step method for {sup 99m}Tc labelling of cysteine-tagged recombinant antibodies with more than 50% radionuclide incorporation. The labelled antibodies displayed full retention of immuoreactivity and good stability. (orig.)

  11. Investigation of space-occupying lesions in the liver with technetium-99m tin colloid and indium-113m-chloride

    International Nuclear Information System (INIS)

    Nelson, M.J.; Klopper, J.F.

    1985-01-01

    Liver scanning with radiocolloids is an important method to determine the presence, the position and the size of space-occupying lesions in the liver. Unfortunately, this information is nonspecific and it is not possible to distinguish between tumours, abscesses or cysts. Thirty-six patients in whom a definite diagnosis of hepatoma, amoebic liver abscess or echinococcus cyst had been made were examined with technetium-99m tin colloid and indium-113m chloride. The amoebic liver abscesses were avascular, showed a hyperaemic area surrounding the abscess and appeared smaller on the indium than on the technetium scan. The hepatomas showed greater vascularity and absence of the hyperaemic area. Cysts were avascular, did not show a hyperaemic rim and the size was equal on both scans. The experience of the observers had an influence on the accuracy of interpretation of the scans; experienced observers made a correct diagnosis in 73% of cases. It is suggested that simultaneous technetium-99m tin colloid and indium 113m-chloride scans provide additional specificity in the differential diagnosis between hepatoma, amoebic liver abscess and echinococcus cysts

  12. Investigation of space-occupying lesions in the liver with technetium-99m tin colloid and indium-113m-chloride

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, M.J. (Provincial Hospital, Port Elizabeth (South Africa). Dept. of Nuclear Medicine); Klopper, J.F. (Stellenbosch Univ. (South Africa). Dept. of Nuclear Medicine)

    1985-01-26

    Liver scanning with radiocolloids is an important method to determine the presence, the position and the size of space-occupying lesions in the liver. Unfortunately, this information is nonspecific and it is not possible to distinguish between tumours, abscesses or cysts. Thirty-six patients in whom a definite diagnosis of hepatoma, amoebic liver abscess or echinococcus cyst had been made were examined with technetium-99m tin colloid and indium-113m chloride. The amoebic liver abscesses were avascular, showed a hyperaemic area surrounding the abscess and appeared smaller on the indium than on the technetium scan. The hepatomas showed greater vascularity and absence of the hyperaemic area. Cysts were avascular, did not show a hyperaemic rim and the size was equal on both scans. The experience of the observers had an influence on the accuracy of interpretation of the scans; experienced observers made a correct diagnosis in 73% of cases. It is suggested that simultaneous technetium-99m tin colloid and indium 113m-chloride scans provide additional specificity in the differential diagnosis between hepatoma, amoebic liver abscess and echinococcus cysts.

  13. Increased uptake of technetium-99m methylene diphosphonate in muscles in the course of polymyositis

    International Nuclear Information System (INIS)

    Niemir, Z.; Oleksa, R.; Czepczynski, R.; Sowinski, J.

    2005-01-01

    A case of a woman aged 46 years with signs of rhabdomyolysis and acute renal failure is presented. Coxsackie serum test was positive. Increased uptake of Technetium-99m methylene diphosphonate ( 99mT c-MDP) by muscles of thighs and calves was observed. After 1 year no increased accumulation of radiotracer in the muscles was found

  14. [99mTc[TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    International Nuclear Information System (INIS)

    Kung Meiping; Stevenson, D.A.; Ploessl, K.; Meegalla, S.K.; Beckwith, A.; Essman, W.D.; Mu, M.; Lucki, I.; Kung, H.F.

    1997-01-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of 99m Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel 99m Tc-labeled tropane derivative, [ 99m Tc[TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [ 99m Tc[TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, β-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [ 99m Tc[TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 μg per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [ 99m Tc[TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [ 99m Tc[TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs

  15. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology

    International Nuclear Information System (INIS)

    Desbouis, D.

    2007-01-01

    Over the last decade, suicide gene therapy has emerged as a very promising method to treat cancer. This therapy consists of introducing new genetic material into the nucleus of cancer cells so that they express a therapeutic protein. The protein leads to a therapeutic effect upon interaction with a prodrug. The most widely used system is the combination of the enzyme Herpes Simplex Virus Thymidine Kinase of type 1 (HSV1-TK) with the nontoxic antiviral prodrug gancyclovir. The efficiency of protein expression is crucial for a successful therapy. Several Positron Emission Tomography (PET) tracers such as 9-[4-[ 18 F]fluoro-3-(hydroxymethyl)butyl]guanine [ 18 F]FHBG) or [ 124 I]iodo-2'-fluoro-2'-deoxy-l-β-D-arabino-furanosyluracil ( 124 I]FIAU) have been shown to be suitable probes for reporting HSV1-TK expression. One aspect of this work was to develop Single Photon Emission Tomography (SPET) reporter probes based on the inexpensive technetium-99m whose physical properties are well-suited for diagnosis (t 1/2 = 6.02 h; E γ = 140 keV). A series of complexes was prepared by derivatizing the precursor 5'-amino-5'-deoxythymidine at position N5' in order to introduce spacers of various lengths (∼ 0-30 aangstroem) carrying tridentate metal chelating entities such as iminodiacetic acid and picolylamine-N-monoacetic acid. The nucleoside derivatives were reacted with the precursors [ReBr 3 (CO) 3 ] 2- and [ 99m Tc(OH 2 ) 3 (CO) 3 ] + to form water-stable organometallic thymidine complexes. Unexpectedly, most of the compounds showed no inhibition of HSV1-TK but a mixed inhibition of the human cytosolic thymidine kinase with K iu values ranging from 4.4-334 μM. Competitive inhibition of HSV1-TK was only observed for the thymidine analogue in which the base and the metal core were separated by a spacer of approximately 30 aangstroem length (K i = 16.3 ± 4.6 μM). This compound also exhibited a mixed inhibition of the hTK1 with K ic = 73 ± 20 μM. When tested in vitro for

  16. Present status of Mo-99/Tc-99m generator in Thailand

    International Nuclear Information System (INIS)

    Khongpetch, Pranom

    2007-01-01

    Isotop Production Program, Office of Atoms for Peace had produced technetium-99m by MEK extraction of Mo-99 obtained from (n,γ) reaction in TRIGA Mark III reactor and supplied to nuclear medicine centers in Bangkok from 1980 to 1997. Because of the difficulty to meet the increased demand and limitation of reactor operation, the production of technetium-99m was stopped in 1997. Presently, there are 21 nuclear medicine centers with 25 SPECT, 7 gamma camera and 3 PET. All nuclear medicine centers are currently using imported Tc-99m generator. (author)

  17. Experimental studies of the physiologic properties of technetium-99m agents: Myocardial transport of perfusion imaging agents

    International Nuclear Information System (INIS)

    Meerdink, D.J.; Leppo, J.A.

    1990-01-01

    The physiologic properties of new technetium-99m-labeled myocardial imaging agents (Tc-99m sestamibi, an isonitrile; and Tc-99m teboroxime, a boronic acid adduct of technetium dioxime) are discussed and compared to thallium-201 (Tl-201). Studies with isolated hearts, subcellular fractions and cell cultures indicate that Tc-99m sestamibi, Tc-99m teboroxime and Tl-201 do not share common transport or sequestration mechanisms. Although peak Tc-99m sestamibi myocardial extraction over time is about half that of Tl-201 at equivalent coronary blood flows, the amount of Tc-99m sestamibi that remains in the heart is similar to that of Tl-201 because of its higher retention efficiency. The high retention efficiency for Tc-99m sestamibi also results in minimal redistribution. In contrast, Tc-99m teboroxime myocardial extraction is higher than that of Tl-201, but its retention is less efficient, resulting in relatively rapid washout characteristics which may quickly result in tracer redistribution. During reperfusion after a no-flow period, Tc-99m sestamibi extraction and retention increase, but for Tc-99m teboroxime and Tl-201 these values tend to decrease. All tracers show adequate transport characteristics for perfusion imaging, and differences in transport and retention should lead to the development of new clinical protocols.27 references

  18. Technetium-99m DMSA preparation: Trivial issues causing severe problems

    International Nuclear Information System (INIS)

    Kumar, V.

    1997-01-01

    Urinary tract infection (UTI) in children involving renal parenchyma, upper collecting system or bladder is one of the major causes for consideration in the diagnosis and management of paediatric nuclear medicine. Acute pyelonephritis is one of the prime causes of morbidity associated with urinary tract infection in children which can lead to progressive renal damage. Technetium-99m dimercaptosuccinic acid (DMSA) is used extensively for the assessment of UTI in paediatrics. The radiopharmaceutical preparation could be influenced by several factors, most of them are trivial, but invariably have severe impact on the quality of the scintiphotographs. This communication is mainly to highlight some of the issues related to 99 mTc-DMSA preparation and the possible precautionary measures that need to be taken to obviate unwarranted problems. (author)

  19. Biodistribution of {sup 99m} technetium labeled creatinine in healthy rats

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, O. [Dokuz Eylul University, Narlidere, Izmir (Turkey). Medical Faculty. Dept. of Animal Research Center; Soylu, A.; Kavukcu, S. [Dokuz Eylul University, Narlidere, Izmir (Turkey). Medical Faculty. Dept. of Pediatrics; Lambrecht, F. Yurt; Durkan, K. [Ege University, Bornova, Izmir (Turkey). Institute of Nuclear Sciences. Dept. of Nuclear Applications]. E-mail: s.kavukcu@deu.edu.tr

    2007-06-15

    The distribution of creatinine, one of the toxic guanidine compounds, in various tissues has not been studied in detail by using radiolabeled creatinine. Our objective was to investigate the biodistribution of creatinine labeled with {sup 99m}technetium ({sup 99m} Tc) by the stannous (II) chloride method in healthy male Wistar rats. Quality controls were carried out by radio thin layer chromatography, high-performance liquid chromatography, and paper electrophoresis. The labeling yield was 85 {+-} 2% under optimum conditions (pH 7 and 100 {mu}g stannous chloride). Rats (N 12) were injected intravenously with {sup 99m} Tc creatinine and their blood and visceral organs were evaluated for {sup 99m} Tc-creatinine uptake as percent of the injected dose per gram wet weight of each tissue (%ID/g). The lowest amount of uptake was detected in the brain and testis. When the rate of uptake was evaluated, only the kidney showed increasing rates of uptake of {sup 99m} Tc-creatinine throughout the study. Kidneys showed the highest amount of uptake throughout the study (P < 0.001 compared to all other organs), followed by liver, spleen and lung tissue. (author)

  20. Migration pathways of hypodermically injected technetium-99 m in dogs

    International Nuclear Information System (INIS)

    Kovacs, F.M.; Mufraggi, N.; Garcia, A.; Pavia, J.; Giralt, I.; Piera, C.; Setoain, J.; Garcia, F.; Prandi, D.; Gotzens, V.

    2000-01-01

    Hypodermic injection of technetium-99 m ( 99 m TC-pertechnetate) at points of low electrical resistance give rise to rapid, longitudinal, and progressive diffusion of the radioactive tracer. We assessed the effect of cutaneous incisions that did not intersect the migration trajectory of 99 m Tc-pertechnetate and the re-establishment of pathways after the suture of incisions that intersected the migration trajectory. Linear and rapid migration of 99 m Tc-pertechnetate was not altered or prevented by incisions that did not intersect the migration pathway. Different patterns of 99 m Tc-pertechnetate spread were found when incisions intersected the radioactive pathways until restoration of the normal migration pathway observed in undamaged skin occurred. In all experiments in which migration of 99 m Tc-pertechnetate was observed, lavage of surgical wounds was followed by disappearance of the 99 m Tc-pertechnetate migration observed around the suture. Linear migration of the tracer was not observed when the incision was left uncovered, filled with petroleum jelly, or with a solid silicone sheet, but it was seen when non-sutured incisions were filled with transonic or silicone gel or covered with a solid silicone sheet parallel to the cutaneous plane. These data show that after a cutaneous incision that intersected the diffusion trajectory of the radioactive tracer, linear migration of 99 m Tc-pertechnetate hypodermically injected at points of low electrical resistance was restored before healing of the cutaneous incision and was independent of incisions made on the skin not overlying the radioactive pathway. A mechanism similar to that of capillary electrophoresis is suggested to explain the hypodermic diffusion of inert particles through specific and constant linear pathways. (orig.)

  1. Technetium-99m ceftizoxime kit preparation

    Directory of Open Access Journals (Sweden)

    Simone Odília Fernandes Diniz

    2005-10-01

    Full Text Available The aim of this work was to prepare a kit of 99mTc-ceftizoxime (99mTc-CFT, with stability and biological activity preserved, able to identify a septic focus (E. coli in the experimental infection model in rats. The preparation of the CFT kit involved the use of lyophilized solutions containing the antibiotic ceftizoxime and the sodium dithionite reducing agent (6.0 mg/mL. After lyophilization, the kit was reconstituted with 1.0 mL of sodium 99mTc-pertechnetate solution (Na99mTcO4- with an activity of 370 MBq. The solution was boiled for 10 min and filtered through a cellulose ester filter. The labeling efficiency was on the order of 92%, remaining stable for six hours and the kit remained stable for two months. The biological activity of the 99mTc-CFT was evaluated by diffusion in agar impregnated with E.coli and S. aureus. Seven Wistar rats, weighing from 200 to 250 g, were used for the development of the septic focus. After 24 hours from the induction of the infectious site (E.coli, the animals were anesthetized and 0.1 mL of 99mTc-CFT (37 MBq was injected into the tail veins of the animals. The images were obtained with a gamma camera one, two and six hours after injection and the regions of interest (ROIs were calculated. The diameters of the inhibition halos for 99mTc-CFT were 27.16 ± 0.23 and 27.17 ± 0.20 for S.aureus and E.coli, respectively, while those for the unlabeled CFT were 30.4 ± 0.33 and 29.43 ± 0.26, respectively. The results for the biodistribution of 99mTc-CFT in infected animals furnished a ratio of 1.97 ± 0.31, 2.10 ± 0.42 and 2.01 ± 0.42 for cpm-target/cpm-no target for the one, two and six-hour periods, respectively. The images showed a clear uptake of labeled antibiotic (99mTc-CFT by the infectious site during the experiment. The results attest to the viability of producing a kit with 99m technetium-labeled ceftizoxime for the investigation of infectious processes.O objetivo deste trabalho foi preparar um kit de Tc

  2. Intercellular Uptake of Technetium-99m Pertechnetate by Different Types of Cell Lines

    International Nuclear Information System (INIS)

    Safri Zainal Abidin; Raizulnasuha Abdul Rashid; Muhammad Afiq Khairil Anuar; Wan Nordiana A Abd Rahman

    2015-01-01

    The purpose of this study is to determine the technetium-99m pertechnetate ( 99m TcO 4 ) intercellular uptake by different types of cell lines. HeLa, human fetal osteoblast (hFOB), glial and glioma cell lines grown in 6-wells culture plates were incubated with 99m TcO 4 of activity of 200, 400, 600, 800 and 1000 μCi for 30 minutes at 37 degree Celsius and 5 % CO 2 humidified atmosphere. After incubation, the cells were washed 3 times with phosphate buffer saline to remove the extracellular traces of 99m TcO 4 . Measurement of the intercellular 99m TcO 4 into the cells was calculated. The intercellular uptake of 99m TcO 4 was found to be inversely correlate to the radioactivity. HHeLa cell shows the highest uptake followed by hFOB, glial and glioma cell lines. Comparison of uptake between normal and cancer cells present indistinguishable results. The findings of this study suggest that the intercellular uptake of 99m TcO 4 is highly dependent on the type of cells despite no significant different of uptake was found between normal and cancer cell lines. The level of radioactivity is also an important determinant factor that influence the uptake of 99m TcO 4 into the cell. The study will be the first precedent toward understanding the cellular characteristics and pharmacokinetic of non-invasive imaging tracer for future molecular imaging and therapy. (author)

  3. Site-specific conjugation and labelling of prostate antibody 7E11C5.3 (CYT-351) with technetium-99m

    International Nuclear Information System (INIS)

    Stalteri, M.A.; Mather, S.J.; Belinka, B.A.; Coughlin, D.J.; Chengazi, V.U.; Britton, K.E.

    1997-01-01

    Attachment of chelating agents to the sugar residues of antibodies for subsequent radiolabelling is an attractive approach since it may have less effect on the immunoreactivity than attachment through lysine residues, which are distributed throughout the antibody and may be present near the antigen binding site. We have attached a new hydrazide-linked chelator CYT-395 (Cytogen Corp., Princeton, N.J.) to the sugar residues of the anti-prostate monoclonal antibody 7E11C5.3 and optimised the conditions for labelling the conjugate with technetium-99m in order to compare the conjugate to 7E11C5.3 antibody labelled directly with technetium using a mercaptoethanol reduction technique. Labelling yields of 70%-90% were obtained at specific activities up to 2000 MBq/mg antibody. The stability of the technetium-labelled conjugate in plasma or to a challenge with 0.1 or 1.0 mM cysteine was similar to that of direct-labelled antibody. In nine patients with prostate cancer, the plasma clearance of the labelled conjugate followed a two-compartment model, with an average β-phase half-life of 31.4±3.9 h. The average urinary clearance at 24 h was 15.3±5.0% of the injected dose. In this group of patients there was no significant difference between the blood and urine clearance of the labelled conjugate, and the clearances of the direct-labelled antibody. (orig.). With 5 figs

  4. Delayed parenchymal transit during Tc-99m MAG3 renography is a valuable sign in diagnosing urinary obstruction in patients with early hydronephrosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Woo; Moon, Dae Hyuk; Kim, Jae Seung; Ryu, Jin Sook; Lee, Hee Kyung [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2002-10-01

    Diuretic renography (DR) can be false negative with upper urinary tract obstruction due to low compliance of the renal pelvis. Delayed parenchymal transit (DPT) may be a valuable sign in case of false negative DR. We compared the diagnostic values of DR and DPT during Tc-99m MAG3 diuretic scan in adults with suspected unilateral obstructive uropathy. Fifty-four patients (male:female=30:24, age: 40.7{+-}15.5 yrs) who underwent Tc-99m MAG3 diuretic scan due to suspicious unilateral obstructive uropathy were analyzed. DR with a T{sub 1/2} of > 15 min was considered as positive for obstruction. DPT was considered to be present when there was delayed appearance of radioactivity in the renal pelvis and prolonged retention of radioactivity in the renal pelvis and prolonged retention of radioactivity in the renal parenchyma. The renal area ratio was defined as the ratio of pixel number of hydronephrotic after intervention, or aggravated hydronephrosis without intervention. Non-obstruction was defined as unchanged hydronephrosis over 6 months. Twenty-six renal units had obstruction and 28 no obstruction. The sensitivities of DR and DPT were 69% (18/26) and 50% (13/26) respectively. Two renal units with DPT but negative DR showed DPT had lower renal area ratio than 7 renal units without DPT (0.97{+-}0.20 vs 1.30{+-}0.41, p<0.05). Differential renal function was not significantly different between these groups. DPT correctly diagnosed all renal units with non-obstruction (specificity 100%), while the specificity of DR was 89% (25/28). DPT during Tc-99m MAG3 diuretic scan may be a valuable sign in diagnosing urinary obstruction especially in patients with false negative DR and early HN.

  5. Delayed parenchymal transit during Tc-99m MAG3 renography is a valuable sign in diagnosing urinary obstruction in patients with early hydronephrosis

    International Nuclear Information System (INIS)

    Lee, Won Woo; Moon, Dae Hyuk; Kim, Jae Seung; Ryu, Jin Sook; Lee, Hee Kyung

    2002-01-01

    Diuretic renography (DR) can be false negative with upper urinary tract obstruction due to low compliance of the renal pelvis. Delayed parenchymal transit (DPT) may be a valuable sign in case of false negative DR. We compared the diagnostic values of DR and DPT during Tc-99m MAG3 diuretic scan in adults with suspected unilateral obstructive uropathy. Fifty-four patients (male:female=30:24, age: 40.7±15.5 yrs) who underwent Tc-99m MAG3 diuretic scan due to suspicious unilateral obstructive uropathy were analyzed. DR with a T 1/2 of > 15 min was considered as positive for obstruction. DPT was considered to be present when there was delayed appearance of radioactivity in the renal pelvis and prolonged retention of radioactivity in the renal pelvis and prolonged retention of radioactivity in the renal parenchyma. The renal area ratio was defined as the ratio of pixel number of hydronephrotic after intervention, or aggravated hydronephrosis without intervention. Non-obstruction was defined as unchanged hydronephrosis over 6 months. Twenty-six renal units had obstruction and 28 no obstruction. The sensitivities of DR and DPT were 69% (18/26) and 50% (13/26) respectively. Two renal units with DPT but negative DR showed DPT had lower renal area ratio than 7 renal units without DPT (0.97±0.20 vs 1.30±0.41, p<0.05). Differential renal function was not significantly different between these groups. DPT correctly diagnosed all renal units with non-obstruction (specificity 100%), while the specificity of DR was 89% (25/28). DPT during Tc-99m MAG3 diuretic scan may be a valuable sign in diagnosing urinary obstruction especially in patients with false negative DR and early HN

  6. Utility evaluation on application of geometric mean depending on depth of kidney in split renal function test using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Lee, Eun Byeul; Ahn, Sung Min; Lee, Wang Hui

    2016-01-01

    99mTc-MAG 3 Renal scan is a method that acquires dynamic renal scan image by using 99mTc-MAG 3 and dynamically visualizes process of radioactive agent being absorbed to kidney and excreted continuously. Once the test starts, ratio in both kidneys in 1-2.5 minutes was measured to obtain split renal function and split renal function can be expressed in ratio based on overall renal function. This study is based on compares split renal function obtained from data acquired from posterior detector, which is a conventional renal function test method, with split renal function acquired from the geometric mean of values obtained from anterior and posterior detectors, and studies utility of attenuation compensation depending on difference in geometric mean kidney depth. From July, 2015 to February 2016, 33 patients who undertook 99mTc-MAG 3 Renal scan(13 male, 20 female, average age of 44.66 with range of 5-70, average height of 160.40 cm, average weight of 55.40 kg) were selected as subjects. Depth of kidney was shown to be 65.82 mm at average for left and 71.62 mm at average for right. In supine position, 30 out of 33 patients showed higher ratio of deep-situated kidney and lower ratio of shallow-situated kidney. Such result is deemed to be due to correction by attenuation between deep-situated kidney and detector and in case where there is difference between the depth of both kidneys such as, lesions in or around kidney, spine malformation, and ectopic kidney, ratio of deep-situated kidney must be compensated for more accurate calculation of split renal function, when compared to the conventional test method (posterior detector counting)

  7. Technetium-99m-Labeled Autologous Serum Albumin: A Personal-Exclusive Source of Serum Component

    OpenAIRE

    Wang, Yuh-Feng; Chen, Yi-Chun; Li, Dian-Kun; Chuang, Mei-Hua

    2011-01-01

    Technetium-99m human serum albumin (99mTc-HSA) is an important radiopharmaceutical required in nuclear medicine studies. However, the risk of transfusion-transmitted infection remains a major safety concern. Autopreparation of serum component acquired from patient provides a “personal-exclusive” source for radiolabeling. This paper is to evaluate the practicality of on-site elusion and subsequent radiolabeling efficacy for serum albumin. Results showed that the autologous elute contained more...

  8. Increased technetium-99 m hydroxy diphosphonate soft tissue uptake on bone scintigraphy in chronic kidney disease patients with secondary hyperparathyroidism

    DEFF Research Database (Denmark)

    Enevoldsen, Lotte Hahn; Heaf, James Goya; Højgaard, Liselotte

    2017-01-01

    In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and/or hyperphosphata......In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and...... patients diagnosed with secondary hyperparathyroidism admitted for Tc-99 m-HDP bone scan. Baseline characteristics and mean concentrations of biochemical markers (including P-calcium and P-phosphate) taken 0-3 months prior to the bone scans were collected. Soft tissue uptake was detected on bone scans....../or hyperphosphataemia. As human vascular smooth muscle cells produce hydroxyapatite during cell culture with increased phosphate levels and as Tc-99 m-HDP/MDP primarily binds to hydroxyapatite, we hypothesized that soft tissue accumulation would be found in patients with hyperphosphataemia. We identified 63 CKD...

  9. Technetium-99m carboxymethylcellulose: A newly developed fibre marker for gastric emptying studies

    International Nuclear Information System (INIS)

    Schade, J.H.; Hoving, J.; Brouweres, J.R.B.J.; Riedstra-van Gent, H.G.; Zijlstra, J.; Dijkstra, J.P.H.

    1991-01-01

    We report a study of technetium-99m-labelled carboxymethyl-cellulose ( 99m Tc-CMC) as a newly developed non-digestible marker of the solid phase of gastric contents. The radiosynthesis is simple and shows a high labelling efficiency. In vitro and in vivo experiments demonstrated stability of the marker in the gastrointestinal tract during the process of gastric emptying. The gastric half-emptying time in ten healthy volunteers of both sexes was 105±17 min (mean±SD). This rate of gastric emptying is similar to that of non-digestible solid-phase markers such as in vivo labelled 99m Tc-chicken liver or radio-iodinated cellulose. In comparison with digestible solid-phase markers such as 99m Tc-labelled pancake or 99m Tc-cooked egg, gastric emptying of 99m Tc-CMC occurred more slowly, confirming the expected behaviour of a non-digestible solid-phase marker. We conclude that 99m Tc-CMC has the advantage of a simple and rapid labelling procedure and may be useful for clinical studies of gastric emptying. (orig.)

  10. A solvent-extraction module for cyclotron production of high-purity technetium-99m.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan

    2016-12-01

    The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99m TcO 4 - , in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na 99m TcO 4 , purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99m Tc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Effects of neutron irradiation on red blood cell labeling with technetium-99m

    International Nuclear Information System (INIS)

    Eng, R.R.; Conklin, J.J.; Grissom, M.P.

    1982-01-01

    The effects of in vivo and in vitro neutron irradiation on red blood cell radiolabeling with technetium-99m (Tc-99m) were studied. Blood from three dogs was irradiated with neutrons (725 rads, free in air dose) followed by radiolabeling with Tc-99m. The three dogs were subsequently whole body, neutron irradiated (250 rads, midline dose); and blood samples were drawn for radiolabeling at 24, 48, 72 and 96 hours post-irradiation. Blood from three control dogs was also drawn and radiolabeled on each day for comparison. The results show that there were no significant differences between the radiolabeling capacities of in vivo or in vitro neutron irradiated and control RBCs

  12. Stability studies on 99mTechnetium(III) complexes with tridentate/monodentate thiol ligands and phosphine ('3+1+1' complexes)

    International Nuclear Information System (INIS)

    Seifert, Sepp; Drews, Antje; Gupta, Antje; Pietzsch, Hans-Juergen; Spies, Hartmut; Johannsen, Bernd

    2000-01-01

    The preparation and characterisation of 3+1+1 technetium complexes of the general formula [Tc(SES)(RS)(PMe 2 Ph)] (SES=tridentate dithiol ligand, E=S, O, NMe; RSH=monothiol ligand) at the n.c.a. level is described. The Tc(III) complexes are prepared in a one-step procedure starting from pertechnetate in yields of 85-95% of radiochemical purity. A comparison of their chromatographic data with the fully characterised 99 Tc complexes indicate the identity of the investigated compounds. Stability studies show that the 99m Tc complexes undergo some alteration in solution. They are oxidised to the 3+1 oxotechnetium (V) complexes and/or decompose in aqueous solution. In challenge experiments performed with glutathione, exchange of the monothiolato ligand occurs in the same manner as known for the 3+1 complexes

  13. Contribution to the study of the red blood cells labelled with chromium-51 and technetium-99 m

    International Nuclear Information System (INIS)

    Canine, M.S.

    1983-01-01

    Although the bindings of Cr-51 and Tc-99 m were both in the β chain of hemoglobin molecule, the results obtained after previous incubations of the RBC with chromium and technetium, and the determinations of the efficiency of the labeling of RBC showed that the points of fixing of chromium and technetium with β chain of hemoglobin were probably different. The observations through the optic microscope allowed the verification that, at the concentration of 100 mg/ml of Cr-50, there were morphologic in the RBC. These modifications were not found after the other treatments. The comparison between scintigraphy obtained with Tc-99 m or Cr-51 RBC suggested that the technique which employs Tc-99 m can be more adequate than the one with Cr-51. (author)

  14. [{sup 99m}Tc]TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Meiping, Kung [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Stevenson, D A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Ploessl, K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Meegalla, S K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Beckwith, A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Essman, W D [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); Mu, M [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Lucki, I [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States); Kung, H F [Department of Radiology, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States)

    1997-04-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of {sup 99m}Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel {sup 99m}Tc-labeled tropane derivative, [{sup 99m}Tc]TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [{sup 99m}Tc]TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, {beta}-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [{sup 99m}Tc]TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 {mu}g per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [{sup 99m}Tc]TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [{sup 99m}Tc]TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs.

  15. Study with radio aerosol of DTPA technetium-99 m in individuals with pulmonary disease by amiodarone

    International Nuclear Information System (INIS)

    Terra Filho, M.

    1989-01-01

    In order to evaluate the role of the clearance of 99 m Technetium chelated to diethylenetriamine-penta-acetate (99 m Tc-DTPA) in amiodarone induced pulmonary disease, 40 individuals were studied in four groups. After spirometry, where a volume-time curve was registered, all individuals inhaled 740 MBq of 99 m Tc-DTPA diluted in 4 ml of saline, for five minutes. Pulmonary images were obtained in a computerized scintillation camera and 9 regions of interest were selected. (author)

  16. An improved method for determination of technetium-99m half-life for the quality assurance procedures of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Abd Jalil Abd Hamid; Juhari Mohd Yusof; Zakaria Ibrahim; Wan Mohd Ferdaus Wan Ishak; Mohamad Hafiz Ahmad

    2009-01-01

    An improve method for identity tests of technetium-99m for the quality assurance procedures are presented. Computerized methods based on the least-squares of decay curve fitting for half-life estimation of technetium-99m was tested. Thus, least-squares method was employ as a decay curve fitting procedures in our software. Theoretical calculated half-life of technetium-99m for evaluation was performed for comparison. In Fig. 3 is shown, the decay curve fitting of a sample over one second counting time interval. The R2 value of the curve suggests that the time of the study was too short to obtain acceptable value. A similar measurement for another data set was done for a longer period of time and in Table 1 is shown a representative decay curve fitting. The value was found to be 6.006 hours with a discrepancy of -0.28% from the value taken from the literature. The value is in agreement with the literature for time interval greater than 2 seconds. The results obtained by this method show that the used of least-squares method for decay curve fitting are appropriate for routine identity tests. This confirmed that the least-squares method applied in our decay curve fitting software are remarkably improved and convenient for routine identity tests purposes. (Author)

  17. Radiolabeling small RNA with technetium-99m for visualizing cellular delivery and mouse biodistribution

    International Nuclear Information System (INIS)

    Liu Ning; Ding Hongliu; Vanderheyden, Jean-Luc; Zhu Zhihong; Zhang Yumin

    2007-01-01

    To develop a noninvasive direct method for the in vivo tracking of small interfering RNA (siRNA) used in RNA interference, two 18-nucleotide oligoribonucleotides were radiolabeled with technetium-99m ( 99m Tc-RNA). The ability of 99m Tc-RNA to track delivery was tested in cultured cells and living mice. The cellular delivery of 99m Tc-RNAs could be quantified by gamma counting and could be visualized by microautoradiography. Radiolabeled RNAs can be efficiently delivered into cells by reaching up to 3x10 5 molecules of small RNAs per cell. Moreover, RNAs were internalized with homogeneous distribution throughout the cytoplasm and nucleus. In tumor-bearing mice, whole-body images and biodistribution studies showed that 99m Tc-RNAs were delivered to almost all tissues after intravenous injection. The imaging of living animals allowed noninvasive and longitudinal monitoring of the in vivo delivery of these small RNAs. In conclusion, using 99m Tc radiolabeling, the delivery of small RNAs could be measured quantitatively in cultured cells and could be noninvasively visualized in living animals using a gamma camera. The results of this study could open up a new approach for measuring the in vivo delivery of small RNAs that might further facilitate the development of siRNAs as targeted therapies

  18. Specifications and Quality of Technetium99m Produced diopharmaceuticals According to Good Manufacturing Practice Regulations

    International Nuclear Information System (INIS)

    Abudaia, Jamal; Ben Othman, Monji H.; Maatoug, Maatoug A.; Maatoug, M. Omar

    2003-01-01

    A Technological revolution has occurred in the last two decades of this century in field of Cold Kits preparations processed by Lyophilization technique (A drying process while frozen) which are labeled afterwards with Technetium-99m radionuclide. Such materials are intended to be used as Radiopharmaceutical probes in nuclear medicine for the diagnosis of dynamic and static conditions of organs, and therefore; uncovering of diseases and syndromes targeting humans. Preferability and the advantages of such kits labeled with Technetium-99m radionuclide over other types of radiopharmaceuticals is attributed to the unique physical properties of the radionuclide including its short half life of 6.02 hours, low photon energy of 140 keV, lacking of alpha and beta particles which are usually exposing patients to have additional exposed doses. Moreover, simplicity in obtaining such radionuclide in form portable generators containing the mother radionuclide Molybdenum - 99 (i.e. solvent extraction generators or adsorption column chromatographic generators) for-on-the- spot-labeling, and the ability of formulating the cold kits as chemical complexes located at different organs of human body. Those lyophilized kits intended for radiopharmaceutical preparations labeled with Technetium - 99m radionuclide must stand for quality assurance standards and assessments for the sake of safety, efficiency, apyrogenecity, radiochemical purity, in- vivo stability and suitability for the endeavor planed for. Therefore, in order to control and optimize those considerations, implementations of the so-called GOOD MANUFACTURING PRACTICE composed of regulations and constitutional laws related to the process of preparation and final produced preparation must take place.(author)

  19. Utility evaluation on application of geometric mean depending on depth of kidney in split renal function test using 99mTc-MAG{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Byeul; Ahn, Sung Min [Dept. of Radiological Science, Gachon University, Incheon (Korea, Republic of); Lee, Wang Hui [Dept. of Nuclear Medicine, Gil-Hospital, Incheon (Korea, Republic of)

    2016-06-15

    99mTc-MAG{sub 3} Renal scan is a method that acquires dynamic renal scan image by using 99mTc-MAG{sub 3} and dynamically visualizes process of radioactive agent being absorbed to kidney and excreted continuously. Once the test starts, ratio in both kidneys in 1-2.5 minutes was measured to obtain split renal function and split renal function can be expressed in ratio based on overall renal function. This study is based on compares split renal function obtained from data acquired from posterior detector, which is a conventional renal function test method, with split renal function acquired from the geometric mean of values obtained from anterior and posterior detectors, and studies utility of attenuation compensation depending on difference in geometric mean kidney depth. From July, 2015 to February 2016, 33 patients who undertook 99mTc-MAG{sub 3} Renal scan(13 male, 20 female, average age of 44.66 with range of 5-70, average height of 160.40 cm, average weight of 55.40 kg) were selected as subjects. Depth of kidney was shown to be 65.82 mm at average for left and 71.62 mm at average for right. In supine position, 30 out of 33 patients showed higher ratio of deep-situated kidney and lower ratio of shallow-situated kidney. Such result is deemed to be due to correction by attenuation between deep-situated kidney and detector and in case where there is difference between the depth of both kidneys such as, lesions in or around kidney, spine malformation, and ectopic kidney, ratio of deep-situated kidney must be compensated for more accurate calculation of split renal function, when compared to the conventional test method (posterior detector counting)

  20. Improved modification for in vitro labeling of red blood cells with Technetium-99m

    International Nuclear Information System (INIS)

    Gerson, B.; Ballinger, J.R.; Gulenchyn, K.Y.

    1988-01-01

    The authors have tested a modification of Brookhaven method for in vitro labeling of red blood cells (RBCs) with technetium-99m by adding an initial centrifugation step and performing the labeling on packed RBCs. This results in reproducible, high labeling efficiencies (99.3% +/- 0.4%, n = 50) after 15 min of incubation. The use of packed RBCs also results in a higher concentration of labeled RBCs (smaller bolus for injection) and less radiation exposure to the technologist. This technique has proved useful for radionuclide angiography, venography, gastrointestinal bleeding studies, and red cell mass determinations. It is particularly advantageous for RBC labeling in patients receiving chemotherapy

  1. Synthesis and evaluation of the 99mtc-complexes of L-cysteine acetyldiglycine (a hybrid of MAG3 and L,L-EC) and of L-β-homocysteine acetyldiglycine

    International Nuclear Information System (INIS)

    Mang'era, K.; Vanbilloen, H.; Cleynhens, B.; Groot, T. de; Bormans, G.; Verbruggen, A.; Verbeke, K.

    2000-01-01

    L-Cysteine acetyldiglycine (L-CAG2), a hybrid compound of L,L-EC and MAG3, and its L-β-homocysteine analogue L-HAG2 were synthesized. After labeling with 99m Tc, 99m Tc-L-CAG2 and 99m Tc-L-HAG2 gave two peaks on high performance liquid chromatography. Urinary excretion of both isomers of 99m Tc-L-CAG2 and 99m Tc-L-HAG2 was slower than for the 'parent' complexes 99m Tc-MAG3 or 99m Tc-L,L-EC. Isomer B of 99m Tc-L-CAG2 showed pronounced kidney retention in mice (57% of ID in kidneys at 30 min postinjection), but further evaluation in baboon did not reproduce this phenomenon

  2. Renal scintigraphy in the 21st Century 99m Tc-MAG3 with zero time injection of furosemide (MAG3-F0): a fast and easy protocol, one for all indications. Part 3. Clinical experience. Congenital disorders

    International Nuclear Information System (INIS)

    Sfakianakis, G.N.

    2007-01-01

    In this work the Protocol for MAG 3 -F 0 is presented. Patient preparation, easy (only restriction, oral hydration, no bladder cathartic). Dynamic study (iv 1-10 mCi MAG 3 + 40-80 mg LASIX), simultaneous injection of furosemide: MAG 3 -F 0 , duration of the study: 25 minutes. Tomography-SPECT (20 mCi MAG 3 ). No diuretic needed, duration of the study: 4 minutes. (Author)

  3. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m*

    Science.gov (United States)

    Abreu, P.R.C.; Almeida, M.C.; Bernardo, R.M.; Bernardo, L.C.; Brito, L.C.; Garcia, E.A.C.; Fonseca, A.S.; Bernardo-Filho, M.

    2006-01-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m (99mTc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with 99mTc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with 99mTc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with 99mTc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with 99mTc. The data showed significant (Pguava extract. PMID:16691636

  4. Thyrotoxic Graves' disease with normal thyroidal technetium-99m pertechnetate uptake

    Energy Technology Data Exchange (ETDEWEB)

    Ikekubo, Katsuji; Hino, Megumu; Ito, Hidetomi; Koh, Toshikiyo; Ishihara, Takashi; Kurahachi, Hiroyuki (Kobe City General Hospital (Japan)); Kasagi, Kanji; Hidaka, Akinari; Mori, Toru

    1990-07-01

    We saw 24 thyrotoxic Graves' patients with normal thyroidal uptake of technetium-99m pertechnetate ({sup 99m}Tc) out of 201 untreated thyrotoxic Graves' patients seen over 4 years. The clinical and laboratory findings for these patients were studied and analyzed. Thyroid uptake and scintigraphic examinations by means of {sup 99m}Tc, TBII and TSab activity measurement clearly distinguished these patients from other thyrotoxic disorders (destruction-induced thyrotoxicosis and autonomously functioning thyroid lesions). Different from other disorders, these patients had not lower but normal thyroid uptake and also showed diffuse and discrete trapping into the enlarged glands. These patients had significantly smaller goiters, a lower serum thyroid hormone level, and lower TBII and TSab activity, when compared with other high {sup 99m}Tc uptake groups with Graves' disease, and their condition could be easily controlled with small amounts of antithyroid drugs. Our study indicates that thyrotoxic Graves' disease with normal {sup 99m}Tc uptake exists and {sup 99m}Tc uptake study and TBII activity measurement is very useful for the diagnosis. The normal {sup 99m}Tc uptake thyrotoxic Graves' patient might be early stage patients with general Graves' disease and their early discrimination from general Graves' patients is very advantageous for treatment and prognosis. (author).

  5. Discussion on twenty-two hepatobiliary scintigraphs performed with technetium 99m-labelled N-(2,6 dimethylphenylcarbamoylmethyl) iminodiacetic acid (or HIDA-99mTc) at the Val-de-Grace Army Instruction Hospital

    International Nuclear Information System (INIS)

    Hoste, Philippe.

    1978-12-01

    Intraveinously injected technetium 99m-labelled N-(2,6 dimethyl-phenylcarbamoylmethyl) iminodiacetic acid, or HIDA-99mTc, is taken up by the hepatocytes and secreted in the bile, a fraction being normally eliminated by the kidneys. Isotopic examination with HIDA-99mTc gives valuable information on the morphology of the liver during the first minutes of the test, thus revealing the presence of parenchyma disease. In all observed cases of secondary hepatic localisations in particular the HIDA-99mTc images overlie those obtained with technetium colloids. By the examination it is also possible: - to establish the existence or otherwise of a functional vesicle, - to follow the path of the radiotracer along the bile duct. In short, HIDA-99mTc hepatobiliary scintigraphy is particularly useful for the study of hepatocyte uptake and bile elimination since it allows a continuous quantitative study of the liver-bile function under given physiological conditions [fr

  6. The technetium-99m DTPA partition test in the diagnosis of tuberculous meningitis

    International Nuclear Information System (INIS)

    Von Wenzel, K.S.; Klopper, J.F.; Wasserman, H.J.

    1989-01-01

    Although the blood/cerebrospinal fluid (CSF) bromide concentration ratio is sensitive and specific in the diagnosis of tuberculous meningitis (TBM), bromide-82 is not always available since it is not generally used in nuclear medicine. The use of technetium-99m diethylenetriamine penta-acetic acid (DTPA) for a partition test was compared with that of 82 Br in 22 cases. Seven patients were diagnosed as having TBM, 9 patients had viral meningitis and 5 patients had septic meningitis. One normal control subject was also studied. Although the mechanism of transfer of substances across the blood-brain barrier as well as the factors affecting it are still unclear, both 82 Br and 99m Tc-DTPA cross the blood-brain barrier to a greater extent in TBM than in viral meningitis. Both tracers thus yield decreased serum/CSF concentration ratios in TBM. The accuracy of the 82 Br partition test was found to be 90,9% if a critical serum/CSF ratio of 1,3 was chosen, compared with 86,9% for the 99m Tc-DTPA partition test if a critical value of 3 was chosen. The use of 99m Tc D TPA offers various advantages, including general availability, lower cost and radiation dose per MBq, as well as the possibility of concomitant brain scintigraphy. 1 tab., 9 refs

  7. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m

    International Nuclear Information System (INIS)

    Monteiro, Elisiane de Godoy

    2012-01-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ( 99 mTc), obtained from 99 Mo/ 99 mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99m Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ( 99 mTcO 4 - ) and technetium colloidal (99mTcO 2 ) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with 99m Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99m TcO 4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL 1 (1,5 mCi mL 1 ) of final radioactive concentration. The % 99m TcO 4 - , % 99m TcO 2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control

  8. The regulation of technetium-99 discharges at Sellafield

    International Nuclear Information System (INIS)

    Mayall, A.

    2002-01-01

    The reprocessing of spent Magnox fuel at BNFL Sellafield produces a liquid waste concentrate containing technetium-99 and other, more radiotoxic, radionuclides such as plutonium and americium. The concentrate is known as medium active concentrate (MAC). Prior to 1981, MAC was discharged to sea untreated after several years' storage, during which short-lived radionuclides underwent radioactive decay. In the early 1980s, discharges of MAC were suspended and it was retained in storage tanks, pending the construction of a plant to remove the radionuclides of greatest radiological concern (these did not include technetium- 99). The Enhanced Actinide Removal Plant started operation in 1994 and began to clear the backlog of stored waste MAC, as well as current arisings from Magnox reprocessing. As a consequence technetium-99 was once more discharged to sea. Subsequently, concentrations of this radionuclide in the marine environment increased. In particular, there was a significant increase in the concentration of technetium-99 in lobster in the Irish Sea. An increase in technetium-99 has also been detected at locations far distant from Sellafield, e.g. in Scandinavian coastal waters, albeit at very low concentrations. This dispersal of technetium- 99 throughout the Irish Sea and further afield has therefore caused concern, although the radiological impact is low. This paper examines the nature and source of the technetium-99 in sea discharges at Sellafield and the levels of past and current discharges as well as their impact. It goes on to describe the Environment Agency's recent proposals on the future regulation of technetium-99 discharges and how these should lead to substantial reductions in not only technetium-99 discharges, but also of other radionuclides such as caesium-137 and strontium-90. (author)

  9. Work in progress. Gastrointestinal ulcerations: detection using a technetium-99m-labeled ulcer-avid agent

    International Nuclear Information System (INIS)

    Vasquez, T.E.; Bridges, R.L.; Braunstein, P.; Jansholt, A.L.; Meshkinpour, H.

    1983-01-01

    Technetium-99m-labeled sucralfate, an ulcer-avid material, was shown in preliminary animal and human studies to be stable in vivo with good sensitivity. Eight experimentally produced discrete gastric ulcers in three rabbits were visualized using this material. Of seven human studies, four studies were true-positive and three were true-negative. It is suggested that Tc-99m-labeled sucralfate may prove to have significant clinical advantages for the evaluation of gastrointestinal ulcer disease and other diseases that are associated with loss of mucosal integrity. The method for labeling sucralfate with Tc-99m was developed by the authors

  10. Clinical significance of /sup 99m/technetium sulfur colloid accumulation in renal transplant patients

    International Nuclear Information System (INIS)

    Kim, Y.C.; Massari, P.U.; Brown, M.L.; Thrall, J.H.; Chang, B.; Keyes, J.W. Jr.

    1977-01-01

    The accumulation of /sup 99m/technetium sulfur colloid (/sup 99m/TcSC) was evaluated in 47 studies performed on 19 renal transplant patients by comparing its transplant activity to its bone marrow accumulation. There was a diagnosis of rejection in 21 of 22 studies (96.5 percent) in which marked transplant accumulation was noted. In 11 studies of patients with a clinical diagnosis of post-transplant acute tubular necrosis (ATN), the transplant activity varied from none to moderate. Rejection developed in 5 of 6 studies with minimal to moderate accumulation. Normally functioning renal transplant patients, or those with ATN and no superimposed rejection, do not show evidence of /sup 99m/TcSC accumulation

  11. Clinical evaluation of technetium-99m infecton for the localisation of bacterial infection

    International Nuclear Information System (INIS)

    Britton, K.E.; Vinjamuri, S.; Hall, A.V.; Solanki, K.; Siraj, Q.H.; Bomanji, J.; Das, S.

    1997-01-01

    The aim of the study was to distinguish infection from inflammation in patients with suspected infection using technetium-99m Infecton. Ninety-nine patients (102 studies) referred for infection evaluation underwent imaging with 400 MBq 99m Tc-Infecton at 1 and 4 h. Most patients had appropriate microbiological tests and about half (56) had radiolabelled white cell scans as well. No adverse effects were noted in any patient. The clinical efficacy of 99m Tc-Infecton depended in part on whether imaging was undertaken during antibiotic therapy for infection or not. In consultation with the microbiologist, 5-14 days of appropriate and successful antibiotic therapy was considered adequate to classify some results as true-negatives. The figures for sensitivity and specificity of 99m Tc-Infecton for active or unsuccessfully treated infection were 83% and 91% respectively. It is concluded that 99m Tc-Infecton imaging contributed to the differential diagnosis of inflammation. It is being used as the first imaging modality when bacterial infection is suspected. (orig.). With 2 figs., 1 tab

  12. Renal handling of technetium-99m DMSA in rats with proximal tubular dysfunction

    International Nuclear Information System (INIS)

    Provoost, A.P.; Van Aken, M.

    1985-01-01

    The renal handling of technetium-/sup 99m/ dimercaptosuccinic acid ([/sup 99m/Tc]DMSA) was studied in rats before and after treatment with Na-maleate (2 mmol/kg i.v.). In the control period, when measured 2 hr after the intravenous injection of [/sup 99m/Tc]DMSA, 39.9% of the injected dose was in the kidneys and 14.6% was in the bladder. After Na-maleate treatment, only 6.4% of the injected dose of [/sup 99m/Tc]DMSA was retained in the kidneys while 37.9% was found in the bladder. Subsequent studies revealed that Na-maleate produced a fall in the glomerular filtration rate, the effective renal plasma flow, and a generalized proximal tubular dysfunction. The latter was characterized by polyuria and an increased excretion of glucose, protein, albumin, calcium, and inorganic phosphate. It was concluded that proximal tubular dysfunction markedly alters the renal handling of [/sup 99m/Tc]DMSA. Whether this augmented urinary excretion is due to an inhibition of reabsorption or an enhanced cellular efflux of [/sup 99m/Tc]DMSA remains to be answered

  13. Current status of Tc-99m production in Thailand

    International Nuclear Information System (INIS)

    Charoen, Sakda

    2003-01-01

    Technetium-99m is the workhorse of nuclear medicine and currently accounts for over 80% of all in vivo diagnostic procedures. In Thailand, Office of Atomic Energy for Peace (OAEP) had experiences in production of Technetium-99m by solvent extraction process and alternative technology for Technetium-99m generator based on zirconium molybdate and titanium molybdate gel generators were also studied. The paper describes past experiences and future plan of Technetium-99m production in Thailand. (author)

  14. Methods for the quality control of macroaggregates and colloids labelled with technetium-99m. Part of a coordinated programme on radiopharmaceuticals

    International Nuclear Information System (INIS)

    Cifka, J.

    1975-09-01

    Comprehensive studies of the antimony sulphide and sulphur colloids labelled with sup(99m)Tc was performed by the authors. Similar studies dealing with human serum albumin macroaggregates labelled with sup(99m)Tc were also initiated. The labelling processes were studied to determine the possible chemical forms of technetium-99m not bound to the colloidal particles. It was found that pertechnetate-99m is not the only possible impurity in the case of the colloids. Technetium-99m may be present as an soluble tartrate complex in the case of antimony sulphide colloid or as a soluble chlorocomplex in the case of the sulphur colloid. Techniques for the control of these colloids were developed. A method for the determination of particle size of the sulphur colloid is also described

  15. Technetium-99m scintimammography in the diagnosis of malignant breast tumors

    Directory of Open Access Journals (Sweden)

    Jauković Ljiljana

    2004-01-01

    Full Text Available Background. Technetium-99m (99mTc tetrofosmin scintigraphy is a new imaging method for the diagnosis of various malignancies, such as lung, thyroid, and most frequently breast neoplasms. The aim of this study was to evaluate the diagnostic reliability of 99mTc-Tetrofosmin breast scintigraphy in the detection of malignant breast disease. Methods. 99mTc -Tetrofosmin scintimammography (SMM was performed in 28 patients with 30 breast lesions suspicious for malignancy. Standard mammography (MM was also done. After surgery, the results of SMM and MM were compared to definitive histopathological findings as the "gold standard". After intravenous injection of radiotracer, SMM was performed in prone and supine views of the thorax, using large field-of-view Gamma camera. Results. The results of SMM were interpreted visually and semiquantitatively, and evaluated as positive or negative. Sensitivity, specificity and accuracy, positive (PPV and negative predictive value (NPV were obtained in relation to histopathology. After comparing the results of SMM and MM, SMM was proved more sensitive (95% for SMM vs. 80% for MM, while the specificity of both methods was similar. Conclusion. The results of this study indicate that the contribution of SMM as a nuclear medicine procedure has its place in the diagnostic protocol for patients suspected of malignant breast cancer.

  16. Evaluation of technetium-99m/rhenium labelled nucleoside analogues as potential radiotracers in oncology[Dissertation 17173

    Energy Technology Data Exchange (ETDEWEB)

    Desbouis, D

    2007-07-01

    Over the last decade, suicide gene therapy has emerged as a very promising method to treat cancer. This therapy consists of introducing new genetic material into the nucleus of cancer cells so that they express a therapeutic protein. The protein leads to a therapeutic effect upon interaction with a prodrug. The most widely used system is the combination of the enzyme Herpes Simplex Virus Thymidine Kinase of type 1 (HSV1-TK) with the nontoxic antiviral prodrug gancyclovir. The efficiency of protein expression is crucial for a successful therapy. Several Positron Emission Tomography (PET) tracers such as 9-[4-[{sup 18}F]fluoro-3-(hydroxymethyl)butyl]guanine [{sup 18}F]FHBG) or [{sup 124}I]iodo-2'-fluoro-2'-deoxy-l-{beta}-D-arabino-furanosyluracil ({sup 124}I]FIAU) have been shown to be suitable probes for reporting HSV1-TK expression. One aspect of this work was to develop Single Photon Emission Tomography (SPET) reporter probes based on the inexpensive technetium-99m whose physical properties are well-suited for diagnosis (t{sub 1/2} = 6.02 h; E{sub {gamma}} = 140 keV). A series of complexes was prepared by derivatizing the precursor 5'-amino-5'-deoxythymidine at position N5' in order to introduce spacers of various lengths ({approx} 0-30 aangstroem) carrying tridentate metal chelating entities such as iminodiacetic acid and picolylamine-N-monoacetic acid. The nucleoside derivatives were reacted with the precursors [ReBr{sub 3}(CO){sub 3}]{sup 2-} and [{sup 99m}Tc(OH{sub 2}){sub 3}(CO){sub 3}]{sup +} to form water-stable organometallic thymidine complexes. Unexpectedly, most of the compounds showed no inhibition of HSV1-TK but a mixed inhibition of the human cytosolic thymidine kinase with K{sub iu} values ranging from 4.4-334 {mu}M. Competitive inhibition of HSV1-TK was only observed for the thymidine analogue in which the base and the metal core were separated by a spacer of approximately 30 aangstroem length (K{sub i} = 16.3 {+-} 4.6 {mu}M

  17. A simple method to determine the blood volume of newborns with serum-albumin labeled with technetium-99m (HSA-sup(99m)Tc)

    International Nuclear Information System (INIS)

    Camargo, E.E.; Vaz, F.A.C.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E. de; Carvalho, N.

    1973-01-01

    A method for determination of small volumes, with which it is determined blood volume of 11 newborns, is described. By injecting through the anterior fontannelle 1 ml a human serum albumin solution labelled with technetium-99m and withdrawing from the posterior fontanelle blood samples of 1.2 to 1.5 ml at 10, 20 and 30 minutes after the injection, the possibility of determining blood volume with only two of these samples without using a standard is shown. Non-significant whole body radiation (3.2 mrad/6h) is shown as well [pt

  18. Utility of 99mTc-MAG3 perfusion indices in the evaluation of renal transplant function during early post-transplantation period

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chung, Soo Kyo

    2000-01-01

    We have examined the utility of 99m Tc-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Our study included 80 renal transplant recipients (48 men and 32 women, mean age:40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of 99m Tc-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN were significantly greater than that of NG. WK-Tmax of AR was significantly longer than than that of NG. K20.3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups

  19. Preparation of crotalus venom radiolabeled with technetium99m as a tool for biodistribution study

    International Nuclear Information System (INIS)

    Pujatti, Priscilla Brunelli; Santos, Raquel Gouvea dos; Simal, Carlos Jorge Rodrigues

    2005-01-01

    Technetium- 99m ( 99m Tc) has been the radionuclide of choice for nuclear medicine procedures and experimental research. Because of its optimal nuclear properties, 99m Tc is suitable for high efficiency detection with the advantage of reduced radiological waste. Crotalus venom (CV) has been shown to reduce tumors in clinical studies and tissue distribution studies are very important for clinical use. The goal of this work was to obtain CV labeled with 99m Tc which preserves its biological activity. After labeling, biological activity was assessed by hemolytic activity evaluation. Labeled and crude venom caused indirect hemolysis provided that the incubation medium contained an exogenous source of lecithin. High yield radiolabeled-CV was obtained and biological activity was preserved. The results suggest that 99m Tc-CV can be a useful tool for biodistribution studies. (author)

  20. Application of measuring 99mTc-MAG3 plasma clearance based on one-compartment model (MPC method) to pediatric patients

    International Nuclear Information System (INIS)

    Koizumi, Kiyoshi; Higashida, Kousuke; Arbab, A.S.; Toyama, Keiji; Arai, Takao; Yoshitomi, Tatsuya.

    1997-01-01

    Measurement of 99m Tc-MAG3 plasma clearance based on 1-compartment model (MPC method) were applied to 12 pediatric patients and evaluated for the factors which might affect the calculated results. Depth correction is a critical factor for the measurement of renal uptake. Three different equations for estimating renal depth were compared with the real depth measured by ultrasonography. The equation proposed by K. Itoh was suitable though the equations by T. Ito and Raynaud were insufficient. Estimation of distribution volume, which is regarded as circulating plasma volume (CPV), is also critical for the calculation of MAG3 clearance by MPC method. Precisely, hematocrit measured by venous sampling and circulating blood volume (CBV) calculated as 7.5% of body weight are used for estimation of CPV. However, assumed CPV as 5% of body weight was acceptable if the hematocrit was not severely deviated from the normal value. Simplified MPC method utilizing two factors mentioned above gave a positive correlation with Russell's one point sampling method. In conclusion, MPC method is applicable for pediatric patients. (author)

  1. Technetium-99m-labelled monoclonal antibody fragment (99mTc-DD-3B6/22Fab') for ovarian cancer

    International Nuclear Information System (INIS)

    Fernandes, V.; Donaghy, T.; Prabakaran, K.; Smith, S.; Clingan, P.; Bartolo, N.; Bundesen, P.; Hillyard, C.

    1998-01-01

    Full text: This study is the first to assess 99m Tc-DD-3B6/22Fab'' as an agent for detecting OC recurrence. Five informed consenting volunteers with stages 3 or 4 OC (mean age 54.2 y) and with negative skin prick test to Fab'' were recruited. All had suspicion of OC recurrence, with elevated serum tumour marker CA125, and in some, OC confirmation on CT scans. Aggressive treatment was continued so that tumour regression was possible prior to 99m Tc-DD-3B6/22Fab''scan. CA125, FBC, biochemical and clot markers were measured pre-and post-study. All received IV 600-800 MBq of 99 mTc-DD-3B6/22Fab''. Temperature, pulse and BP were monitored for one hour. Data were acquired with a single head LFOV gamma camera and HIRES collimator at 1,4,6 and 24 hours. Studies were read for OC lesions which were scored as probably normal (PN) or abnormal (PAb), definitely abnormal (DAb). The gold standard was CA125 immediately post-scan and, when possible, confirmation with CT. Of 5 patients, 1 was disease negative with 99 mTc-DD-3B6/22Fab'', CA125 suggesting remission, and 4 were positive on all modalities (Sensitivity, specificity, 100% respectively). 99 mTc-DD-3B6/22Fab'' identified 15 lesions (100% DAb). CT detected 7 lesions (71% Dab) pre- 99 mTc-DD-3B6/22Fab''. Repeat CT detected 8 (100% DAb). Correlation with CA125 levels was best with 99 mTc-DD3B6/22Fab''. No side effects or adverse change in serum markers were noted. 99 mTc-DD-3B6/22Fab'' is sensitive and specific for detecting OC recurrence

  2. Studies on the production of technetium-99m generators based on gel elution

    International Nuclear Information System (INIS)

    Castro, M.

    1993-12-01

    Technetium-99m generator based on Ti Mo elution has been carried out. The gel matrix was prepared by mixing non-irradiated molybdate with Titanium Chloride solution. Conditions of preparing and drying Ti Mo were evaluated as a function of elution yield. Thus, pH and water content were found highly critical for reproductiveness of the results. Non-elutable form of Tc-99m can be oxidized treating the target after irradiation with K 2 Cr 2 O 7 0.001M solution. During several experiments the columns were soaked with this oxidizing solution for one hour and afterwards the Ti Mo was washed with 150 ml physiological saline. Daily elutions were done with 10 ml of NaCl 0.9%. Cooling water reactor during irradiation quartz ampoules has been studied. To study this effect, one group of samples were irradiated in aluminium caps air-tight screw and another one was irradiated in drilled caps with six holes to permit water reactor recirculation around quartz ampoules. By combination K 2 Cr 2 O 7 target treatment and cooling Ti Mo during irradiation is possible to get yields of Tc-99m near to 76%. The radiochemical purity was > 99% and Al content < 10ppm , Cr < 0.05ppm , Mo <20ppm, Ti was no detected. Biological scans practiced in animals have been considered satisfactory. (author). 8 refs., 7 tabs., 3 figs

  3. Technetium-99m-labeled recombinant tissue plasminogen activator for the imaging of emboli in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiro; Itoh, Kazuo; Tsukamoto, Eriko; Furudate, Masayori; Kamiyama, Hiroyasu; Abe, Hiroshi [Hokkaido Univ., Sapporo (Japan). School of Medicine

    1993-07-01

    Tissue-type plasminogen activator (t-PA) effectively lyses activate thrombus by direct action. Recombinant t-PA (rt-PA) was labeled with technetium-99m ([sup 99m]Tc) to investigate the in vivo binding to fibrin clots in a feline cerebral embolism model created by insertion of an artificial fibrin clot within the carotid artery. [sup 99m]Tc-rt-PA administered intravenously provided clearer imaging of clots after priming with cold rt-PA, with uptake peaking 5-10 minutes after the injection. [sup 99m]Tc-labeled human serum albumin was not retained at clot sites. Systemically administered [sup 99m]Tc-rt-PA binds to fibrin clots within carotid arteries in our feline model. Our results suggest that the interaction of intrinsic plasminogen activator inhibitors with extrinsically administered rt-PA may regulate the demonstration of a clot, although the precise mechanism is unclear. (author).

  4. Technetium-99m labeling and fibronectin binding ability of Corynebacterium diphtheriae

    International Nuclear Information System (INIS)

    Souza, S.M.S.; Nagao, P.E.; Bernardo-Filho, M.; Pereira, G.A.; Napoleao, F.; Andrade, A.F.B.; Hirata Junior, R.; Mattos-Guaraldi, A.L.

    2004-01-01

    The use of radionuclides has permitted advances in areas of clinical and scientific knowledge. Several molecules and cells have been labelled with Technetium-99m ( 99m Tc). The stannous chloride (SnCl 2 ) has a significant influence on the labeling and stability of 99m Tc radiotracers. The frequent risk of diphtheria epidemics has intensified interest in the virulence factors of Corynebacterium diphtheriae. Although studies have looked at potential adhesins including haemagglutinins and exposed sugar residues, the molecular basis of mechanisms of adherence remains unclear. Adherence of pathogens to mammalian tissues may be mediated by fibronectin (FN) found in body fluids, matrix of connective tissues, and cell surfaces. In the present study we evaluated the binding ability to human plasma FN by 99m Tc labeled-C.diphtheriae. Due to adverse effects of stannous ions, microorganisms were submitted to survival and filamentation induction assays. Data showed a dose dependent susceptibility to SnCl 2 bactericidal effects. Cell filamentation was observed for concentrations of SnCl 2 > 110 μg/ml. Adherence levels of 99m Tc labelled 241strain to coverslips coated with 20 μg/ml FN were higher (P = 0.0037) than coated with bovine serum albumin. FN binding by the sucrose fermenting 241 C. diphtheriae strain (8.9% + 2.6) was significantly lower (P=0.0139) than Staphylococcus aureus Cowan I strain (34.1% ± 1.2). Therefore, bacterial 99m Tc labeling represents an additional tool that may contribute to the comprehension of C. diphtheriae interactions with host receptors such as FN that act as biological organizers by holding bacterial cells in position and guiding their migration. (author)

  5. Technetium-99m methylene diphosphonate scintimammography for evaluation of palpable breast masses

    International Nuclear Information System (INIS)

    Shah, S.; Khan, M.M.; Khan, A.U.; Khan, S.M.; Khan, A.A.

    2002-01-01

    Objective:To evaluate technetium-99m methylene diphosphonate (/sup 99m/Tc-MDP) as a noninvasive tumor-localizing agent in patients with palpable breast masses and to differentiate malignant from benign breast lesions. Design: It was an observational and experimental study. Place and Duration of Study: the study was conducted at the Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar during a six-month period (June to November, 1995). Subjects and Methods: 99m Tc-MDP scintimammography (SMM) was performed in thirty patients with palpable breast masses (Group A). Ten patients with no palpable breast abnormality (Group B) also underwent /sup 99m/Tc-MDP breast study; they served as controls. Upright anterior, lateral and oblique lateral images of the breasts were acquired 10-30 minutes after intravenous injection of 740 MBq of /sup 99m/Tc-MDP. This was performed during routine bone scanning. SMM was followed by surgical and /or needle biopsy. Results: breast cancer was histologically diagnosed in twenty two (73%), and benign disease found in eight patients (27%). Of the twenty two breast carcinomas, twenty (91%) were detected using /sup 99m/Tc-MDP SMM, while no uptake was seen in two (9%). Of the eight patients with pathologically proven benign breast lesions, seven (88%) either did not show any uptake or showed faint bilateral accumulation. Focal /sup 99m/Tc-MDP uptake was observed in one fibroadenoma. Conclusion: The study showed that SMM with /sup 99m/Tc-MDP is positive in a high percentage of patients with carcinoma of the breast and may differentiate malignant from benign masses. (author)

  6. evaluation of some technetium-99m fluoroquinolones complexes as imaging agents for bacterial inflammatory lesions

    International Nuclear Information System (INIS)

    Abdel-Kawy, O.A.A.

    2007-01-01

    in this study, the labeling method of ciprofloxacin and levofloxacin with technetium-99m and their biological evaluation in man-induced inflammation models were described . in -vitro microbiological evaluation of both complexes was also performed in order to investigate the effect of labeling on the activity and spectrum of both antibiotics. all the gathered biological data support the usefulness of 99m Tc-fluoroquinolones as infection imaging agents that could discriminate between infections and sterile inflammations. the freeze-dried form of levofloxacin kits was prepared and found to meet all the radiochemical and biological tests

  7. Application of photoactivation in the preparation of radiopharmaceuticals. Pt. 3. Human serum albumin labelled with technetium (99mTc)

    International Nuclear Information System (INIS)

    Komarek, P.; Kleisner, I.; Konopkova, M.; Komarkova, I.

    1997-01-01

    Human serum albumin was photoactivated with UV light at 254 nm and labelled with technetium ( 99m Tc) by reducing pertechnetate ( 99m Tc) with stannous chloride. Radiochemical purity was determined by using paper chromatography, columns and electrophoresis. The biodistribution of labelled albumin in rats was assessed by activity counting in isolated organs 15 and 60 minutes after administration. Photoactivation increases the number of free SH groups, which affect favourably the labelling efficiency. Irradiated albumin exhibits a higher labelling efficiency (99%) than non-irradiated albumin (96%). The structural changes depend on the UV radiation dose, concentration of irradiated substances, and metal ion content (Sn 2+ ). The results obtained suggest that the elimination from blood of albumin whose structure has been altered by photoactivation can be accelerated, thereby creating favourable conditions for its application in the diagnosis of inflammatory diseases. (author)

  8. Labelling and quality control of 99mTc labelled somatostatin analogues

    International Nuclear Information System (INIS)

    Poramatikul, N.; Sangsuriyan, J.; Kongpeth, P.; Ngamprayad, T.; Laloknam, S.; Permtermsin, C.; Madsomboon, N.

    2001-01-01

    To standardize interlaboratory reproducibility, iodination of RC-160 with 125 I and direct labelling of RC-160 with 99m Tc, quality control and binding assay were performed. Two conjugated peptides, HYNIC-RC-160 and MAG-3-RC-160, were synthesized. The conjugated peptides were radiolabelled with 99m Tc via co-ligands; 99m Tc-MAG-3-RC-160 via glucoheptonate, 99m Tc-HYNIC-RC-160 via EDDA and tricine. Conditions for labelling were optimized. Analytical and purification methods for the labelled products were developed. Radiochemical purity test of 99m Tc labelled peptides was performed by HPLC with gradient elution of 0.1%TFA/water and acetonitrile, or by ITLC-SG in saline and in 50% acetonitrile. The contaminants in 99m Tc radiolabelled product were separated by elution from SEPPAK C-18 cartridge by 0.1% acetic acid and the pure product was eluted out of SEPPAK column by 50% acetonitrile with about 68% recovery. Stability of the purified 99m Tc-MAG3-RC-160 stored at -20 deg. C was more than 72 h. 99m Tc-MAG-3-RC-160 showed a high equilibrium dissociation constant with K D of 26 pmole/mg protein and B max of 7.9 mM. (author)

  9. Utility of {sup 99m}Tc-MAG3 perfusion indices in the evaluation of renal transplant function during early post-transplantation period

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Chung, Soo Kyo [College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2000-12-01

    We have examined the utility of {sup 99m}Tc-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Our study included 80 renal transplant recipients (48 men and 32 women, mean age:40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of {sup 99m}Tc-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN were significantly greater than that of NG. WK-Tmax of AR was significantly longer than than that of NG. K20.3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups.

  10. Technetium-99m-labeled N-(2,6-dimethylphenylcarbamoylmethyl) iminodiacetic acid (/sup 99m/Tc HIDA): a new radiopharmaceutical for hepatobiliary imaging studies. [/sup 14/C, /sup 113/Sn

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, J.; Cooper, M.; Loberg, M.; Harvey, E.; Sikorski, S.

    1977-10-01

    An easily formulated, stable kit preparation of technetium-99m HIDA, suitable for use in humans, was developed and tested in mice and dogs. The tracer was cleared rapidly from the blood and excreted predominantly by the liver in both species. In dogs, the hepatobiliary clearance of Tc-99m HIDA was significantly greater than that of C-14 HIDA and Sn-113 HIDA. The LD/sub 50/ for HIDA in mice, 168 mg/kg, exceeded the average human dose by a factor of 1000 on a per-weight basis. Blood clearance curves for Tc-99m HIDA in 12 normal subjects were biexponential with half-times of 4.6 +- 1.0 min and 31.5 +- 7.0 min, and cumulative 90-min urine samples contained 14.2 +- 1.8% of the injected dose. Images in normal subjects and nonjaundiced patients showed rapid concentration of tracer by the liver and activity was present within the biliary system in 10 to 20 min. In jaundiced patients, the tracer blood clearance was delayed and urinary excretion increased, but intestinal activity, indicating biliary patency, was imaged in those patients without complete focal obstruction of the common duct. Technetium-99m HIDA is a nontoxic radiopharmaceutical useful for clinical evaluation of hepatobiliary disorders in humans.

  11. Bone-seeking /sup 99m/Tc complex

    International Nuclear Information System (INIS)

    Subramanian, G.; McAfee, J.G.

    1977-01-01

    A bone-seeking, technetium-99m-tin-phosphonate complex effective as a skeletal-imaging agent has been found particularly useful for diagnostic purposes. Skeletal tissue concentrations or technetium-99m obtained with the complex compare favorably to other bone-seeking radionuclides

  12. Technical considerations in gastric ulcer localization using technetium-99m sucralfate

    International Nuclear Information System (INIS)

    Garrett, S.G.; Wcislo, W.J.

    1985-01-01

    After the completion and evaluation of 17 patients studies using technetium-99m-labeled sucralfate for the detection of ulcerated areas, the authors felt that the technical aspects of the studies should be evaluated. The factors for evaluation are: the time the patient is kept fasting; the time the patient is being imaged and rotated for various anatomic views; the technologist time and camera time that are involved in one study; and the cost factor of the testing procedure. Based on the findings of their small sample of patients, the sensitivity of the test is uncertain

  13. Technical considerations in gastric ulcer localization using technetium-99m sucralfate

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, S.G.; Wcislo, W.J.

    1985-09-01

    After the completion and evaluation of 17 patients studies using technetium-99m-labeled sucralfate for the detection of ulcerated areas, the authors felt that the technical aspects of the studies should be evaluated. The factors for evaluation are: the time the patient is kept fasting; the time the patient is being imaged and rotated for various anatomic views; the technologist time and camera time that are involved in one study; and the cost factor of the testing procedure. Based on the findings of their small sample of patients, the sensitivity of the test is uncertain.

  14. Technetium-99m labelled fluconazole and antimicrobial peptides for imaging of Candida albicans and Aspergillus fumigatus infections

    Energy Technology Data Exchange (ETDEWEB)

    Lupetti, Antonella [Department of Infectious Diseases, Leiden University Medical Center (LUMC), Leiden (Netherlands); Dipartimento di Patologia Sperimentale, Biotecnologie Mediche, Univ. di Pisa (Italy); Welling, Mick M. [Department of Radiology, Division of Nuclear Medicine, LUMC, Leiden (Netherlands); Mazzi, Ulderico [Dipartimento di Scienze Farmaceutiche, Universita degli Studi di Padova (Italy); Nibbering, Peter H. [Department of Infectious Diseases, Leiden University Medical Center (LUMC), Leiden (Netherlands); Pauwels, Ernest K.J. [Department of Radiology, Division of Nuclear Medicine, LUMC, Leiden (Netherlands); Department of Radiology, Leiden University Medical Center (LUMC) (Netherlands)

    2002-05-01

    The aim of this study was to investigate whether technetium-99m labelled fluconazole can distinguish fungal from bacterial infections. Fluconazole was labelled with {sup 99m}Tc and radiochemical analysis showed less than 5% impurities. The labelling solution was injected into animals with experimental infections. For comparison, we used two peptides for infection detection, i.e. UBI 29-41 and hLF 1-11, and human IgG, all labelled with {sup 99m}Tc. Mice were infected with Candida albicans or injected with heat-killed C. albicans or lipopolysaccharides to induce sterile inflammation. Also, mice were infected with Staphylococcus aureus or Klebsiella pneumoniae. Next, accumulation of {sup 99m}Tc-fluconazole and {sup 99m}Tc-labelled peptides/IgG at affected sites was determined scintigraphically. {sup 99m}Tc-fluconazole detected C. albicans infections (T/NT ratio=3.6{+-}0.47) without visualising bacterial infections (T/NT ratio=1.3{+-}0.04) or sterile inflammatory processes (heat-killed C. albicans: T/NT ratio=1.3{+-}0.2; lipopolysaccharide: T/NT ratio=1.4{+-}0.1). C. albicans infections were already seen within the first hour after injection of {sup 99m}Tc-fluconazole (T/NT ratio=3.1{+-}0.2). A good correlation (R{sup 2}=0.864; P<0.05) between T/NT ratios for this tracer and the number of viable C. albicans was found. Although {sup 99m}Tc-UBI 29-41 and {sup 99m}Tc-hLF 1-11 were able to distinguish C. albicans infections from sterile inflammatory processes in mice, these {sup 99m}Tc-labelled peptides did not distinguish these fungal infections from bacterial infections. It is concluded that {sup 99m}Tc-fluconazole distinguishes infections with C. albicans from bacterial infections and sterile inflammations. (orig.)

  15. Renal scintigraphy in the 21st Century {sup 99m} Tc-MAG{sub 3} with zero time injection of furosemide (MAG{sub 3}-F{sub 0}): a fast and easy protocol, one for all indications. Part 3. Clinical experience. Congenital disorders

    Energy Technology Data Exchange (ETDEWEB)

    Sfakianakis, G.N. [Professor of Radiology and Pediatrics, Director Division of Nuclear Medicine, University of Miami, School of Medicine, Florida (United States)

    2007-07-01

    In this work the Protocol for MAG{sub 3}-F{sub 0} is presented. Patient preparation, easy (only restriction, oral hydration, no bladder cathartic). Dynamic study (iv 1-10 mCi MAG{sub 3} + 40-80 mg LASIX), simultaneous injection of furosemide: MAG{sub 3}-F{sub 0}, duration of the study: 25 minutes. Tomography-SPECT (20 mCi MAG{sub 3}). No diuretic needed, duration of the study: 4 minutes. (Author)

  16. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction

    International Nuclear Information System (INIS)

    Koster, K.; Wackers, F.J.; Mattera, J.A.; Fetterman, R.C.

    1990-01-01

    Standard interpolative background subtraction, as used for thallium-201 ( 201 Tl), may create artifacts when applied to planar technetium-99m-Sestamibi ( 99m Tc-Sestamibi) images, apparently because of the oversubtraction of relatively high extra-cardiac activity. A modified background subtraction algorithm was developed and compared to standard background subtraction in 16 patients who had both exercise-delayed 201 Tl and exercise-rest 99m Tc-Sestamibi imaging. Furthermore, a new normal data base was generated. Normal 99m Tc-Sestamibi distribution was slightly different compared to 201 Tl. Using standard background subtraction, mean defect reversibility was significantly underestimated by 99m Tc-Sestamibi compared to 201 Tl (2.8 +/- 4.9 versus -1.8 +/- 8.4, p less than 0.05). Using the modified background subtraction, mean defect reversibility on 201 Tl and 99m Tc-Sestamibi images was comparable (2.8 +/- 4.9 versus 1.7 +/- 5.2, p = NS). We conclude, that for quantification of 99m Tc-Sestamibi images a new normal data base, as well as a modification of the interpolative background subtraction method should be employed to obtain quantitative results comparable to those with 201 Tl

  17. Preparation of lyophilized kit of HYNIC-[Tyr3]-Octreotate and labelling studies with 99m-Technetium

    International Nuclear Information System (INIS)

    Melo, Ivani Bortoleti

    2008-01-01

    The development of radiolabeled molecules with high specificity for an organ ar tumor has been contributed to the precise diagnostic in nuclear medicine. Somatostatin labeled derivatives constitutes a particular example of labeled peptide applied in the localization of neuroendocrine tumors. Nowadays, the 111 In DTPA-octreotide is the radiopharmaceutical applied in diagnostic procedures for the visualization of tumors with high expression of somatostatin receptors. However, the 111-indium is a radionuclide that presents some limitations related to availability (cyclotron production), half-life (67 hours) and the emission of medium energy photons (171 keV e 245 keV), not favorable to the acquisition of images in SPECT (Single Photon Emission Computed Tomography). The favorable physical properties of the 99m -technetium ( 99m Tc) make this radionuclide the more favorable to substitute the 111-indium on peptide labeling procedures. This work studied the preparation and labeling of a lyophilized kit of HYNIC-Tyr 3 -octreotate (HYNIC-octreotate) with 99m Tc, base on previously described procedures and using tricine and EDDA (ethylendiaminediacetic acid) as coligands. It was studied the labeling parameters (incubation time, temperature, volume and perthecnetate activity) and the stability of the lyophilized preparation. Additionally, it was studied the influence of the pre-freezing using liquid nitrogen in the stability of the lyophilized preparation, as well as the influence of manitol in the labeling yield and biological distribution of the complex. The stability studies showed that the lyophilization using liquid nitrogen pre-freezing resulted in a lyophilized preparation with stability over 4 month when stored under refrigeration. The stability of the lyophilized preparation obtained without liquid nitrogen pre-freezing was similar.The labeling studies determined the best labeling conditions, resulting in a radiochemical yield superior than 90%. The use of manitol in

  18. Effect of expression of P-glycoprotein on technetium-99m methoxyisobutylisonitrile single photon emission computed tomography of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Yasushi; Matsumura, Akira; Nose, Tadao [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-08-01

    The expression of P-glycoprotein was investigated imunohistochemically in 26 brain tumor tissues and compared with the findings of technetium-99m methoxyisobutylisonitrile single photon emission computed tomography ({sup 99m}Tc-MIBI SPECT) to clarify the effect of P-glycoprotein on the diagnostic accuracy. P-glycoprotein labeling index of both tumor cells and vascular endothelial cells showed no clear relationship with the findings of {sup 99m}Tc-MIBI SPECT imaging. Expression of P-glycoprotein has no effect on the diagnostic accuracy of {sup 99m}Tc-MIBI SPECT. (author)

  19. Synthesis, characterization and biodistribution of technetium complexes (99Tc/99mTc) with 2-amino-2-deoxy-D-hexose oximes

    International Nuclear Information System (INIS)

    Steinmetz, H.J.

    1993-05-01

    In the present work, the synthesis and isolation of isomeric complexes of technetium ( 99 Tc/ 99m Tc) with the 2-amino-2-deoxy-D-hexoses D-glucose aminoxime, D-galactose aminoxime and D-mannose aminoxime, the characterization of the complexes as 99 Tc compounds, and bio-distribution studies on the analogous 99m Tc complexes have been untertaken. As a first step, the free ligands were synthesized and identified using elemental analysis, infra-red and nuclear magnetic resonance spectroscopy and FAB mass spectroscopy. In the bio-distribution studies on the 99m Tc complexes of D-glucose aminoxime and of D-galactose aminoxime in NMRI mice, significant short-term accumulation of 99m Tc activity in heart muscle could be detected, which may be attributed to a biochemical transport mechanism. Uptake in the lungs and the liver was found, but a more significant uptake was observed in the kidneys, where the complexes were rapidly secreted in proportion to their concentration in the blood plasma. (orig./BBR) [de

  20. Corrosion and antifouling characteristics of technetium 99 in seawater

    International Nuclear Information System (INIS)

    Spitsyn, V.I.; Strekalov, P.V.; Balakhovskij, O.A.; Mikhajlovskij, Yu.N.

    1982-01-01

    The results are presented of studying the corrosive and antifouling properties of metallic technetium-99 in the Barents Sea and the Sea of Japan. Foil of 99 Tc glued on acrylic plastic served as a sample. High corrosion resistance and antifouling properties exhibited by 99 Tc in seawater point to favorable prospects of further studies aimed at development of new methods for protection against corrosion and fouling of metallic structures and parts with the use of technetium. The antifouling properties of technetium would evidently be used most efficiently when coating materials of high corrosion resistance to seawater (titanium, stainless steels, special alloys, etc.) with layers of technetium. The use of technetium for coating low-alloyed or carbon steels employed in seawater is yet problematic

  1. Preparation and assessment of [99mTc]technetium aquacarbonyl complexes with 1,2-diaminoethane-N-substituted ligands for tumor detection

    International Nuclear Information System (INIS)

    Radin, Adriano

    2010-01-01

    Over least 15 years the complex [[ 99m Tc](H 2 0) 3 (CO) 3 ] + has been used as an intermediary to obtain technetium radiopharmaceuticals for applications in cardiology, neurology and oncology. Two important characteristics of this molecule are: the facility for obtaining that compound from aqueous solutions and the easiness of substituting H 2 O molecules by atoms of other ligand molecules. In this project we prepared new complexes [[ 99m Tc](CMN S001-3 )(H 2 O)(CO) 3 ] + , where (CMNS001) = N-[(4-methoxy) benzyl]-1,2-diaminoethane, (CMNS003) = N,N'-bis-[(4-methoxy)benzyl]-1,2-diaminoethane, and assessed the uptake of these complexes in murine melanoma cancer cell B16F10 and breast cells MCF-7 and MDA-MD-231, and compared with [[ 99m ](MIBI) 6 ] + uptake. In vitro uptake for both new technetium complex reached values close to 5%, for all cell lines, whereas the [[ 99m Tc](MIBI) 6 ] + uptake was close to 1 %. The assessment of subcellular distribution showed high accumulation of the new complex in the membrane fraction, for MDAMB-231, while for B16F10 accumulation occurred both in membrane and cytoplasm; the concentration of [[ 99m Tc](MIBI) 6 ] + was mainly in the cytoplasm portion. Biodistribution study in mice allowed to observe the capture of up to 1.6% of the administered dose per gram of tumor tissue for the complex [[ 99m Tc](CMNS001)(H 2 O)(CO) 3 ] + , whereas other organs such as heart, lung and muscle, showed uptake of about 5.6%, 6.4% and 2%, respectively. The complexes in this work showed a high rate of uptake in vitro, but was not reproduced in vivo model, which can be related to low concentration of the complexes inside the cells and reduced vascularity of tumor tissue, with lower intake of complex through the blood system. (author)

  2. Monitoring of airborne contamination during the handling of technetium-99m and radioiodine

    International Nuclear Information System (INIS)

    Eadie, A.S.; Horton, P.W.; Hilditch, T.E.

    1980-01-01

    Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99 Tcsup(m) can be safely handled in environments without direct exhaust of the ventilated air but that 125 I and 131 I should always be handled in a ventilated environment such as a fume cupboard or a down-draught work-station of the total-exhaust type. Monitoring of thyroid uptake proves to be the most reliable means of monitoring airborne contamination by these radionuclides, but burdens and radiation doses for typical procedures are well within the maximum permissible limits of the Code of Practice for the Protection of Persons from Ionizing Radiation arising from Medical and Dental Use. (author)

  3. Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Pons, F.; Vidal-Sicart, S.; Fuster, D.; Herranz, R.; Torregrosa, J.V.; Sabater, L.; Fernandez-Cruz, L.

    1997-01-01

    Technetium-99m sestamibi scintigraphy has become a valuable tool in locating parathyroid glands in patients with primary hyperparathyroidism. The aim of this study was to evaluate its usefulness in secondary hyperparathyroidism. Twenty patients were injected intravenously with 740 MBq of 99m Tc-sestamibi and images were obtained at 15 min and 2 h post injection. All patients underwent parathyroid ultrasonography (US) as well as bilateral surgical neck exploration and 64 parathyroid glands were removed. US revealed at least one enlarged gland in 15/20 patients (75%), while 99m Tc-sestamibi scintigraphy showed focal areas of increased uptake in at least one gland in 17/20 patients (85%). When imaging results for all glands were evaluated according to surgical results, sensitivity was 54% for parathyroid scintigraphy and 41% for US, and specificity was 89% for both imaging techniques. There was a discrepancy between the two imaging modalities in 28 glands (35%). The mean surgical weight of US-positive glands (1492±1436 mg) was significantly higher than that of US-negative glands (775±703 mg) (P 99m Tc-sestamibi scintigraphy are complementary imaging techniques in the preoperative localization of abnormal parathyroid glands in patients with secondary hyperparathyroidism. The limited sensitivity of the techniques means that patients will still require bilateral neck exploration; therefore routine preoperative parathyroid scanning in renal patients is not justified. (orig.)

  4. Synthesis, radiochromatography and biodistribution of Tc99m-hexakis-(methoxyisonitrile)-technetium(I) complexes

    International Nuclear Information System (INIS)

    Angelberger, P.; Zbiral, E.

    1987-09-01

    Following previous experience with Tc-99m-hexakis(t-butyl-isonitrile)-technetium(I) (Tc99m-tBiN) synthetic routes to the new ligands a) 1-methoxypropyl-2-isonitrile (MPiN) and b) 2-methoxy-2-methylpropyl-1-isonitrile(MiBiN) were developed via dehydration of the corresponding formamides. Formamide (a) was prepared from the available amine (a) while formamide (b) was synthesised by a difficult 5 step sequence starting from tert.2,2,2-trichlorobutanol. Product MPiN and MiBiN was purified by vacuum distillation and characterized by elemental analysis, IR- and NMR-spectra. A labeling method was developed based on earlier work with Tc99m-tBiN :the pure isonitrile ligand in ethanolic/aqueous solution was complexed at elevated temperature with reduced Tc-99m formed in situ with dithionite at alkaline pH. The whole reaction mixture was subjected to preparative HPLC leading to identification by UV-absorption and isolation of pure n.c.a. Tc99m-MPiN (A) and Tc99m-MiBiN (B) free of unreacted ligand. Work-up of the isolated peak resulted in an injectable product (overall radiochemical yield ∼80% within ∼40 min total preparation time) which was further controlled by TLC (radiochemical purity >97%, in vitro stability >6 hrs). Biodistribution in mice compared to identical data obtained with Tc99m-tBiN revealed somewhat higher heart uptake, slightly lower lung but significantly lower liver activity and renders these new Tc99m-compounds highly promising for myocardinal perfusion studies in man. 11 refs., 5 figs. (Author)

  5. Synthesis, characterization and identification of the hexakis (trimethylphosphite) [Tc-99m]technetium(I) cation as a myocardial imaging agent

    International Nuclear Information System (INIS)

    Dean, R.T.; Adams, M.D.; Miller, F.W.; Robbins, M.S.; Wester, D.W.; White, D.H.

    1984-01-01

    Hexakis(trimethylphosphite)[Tc-99m]technetium(I), a monocationic complex, was synthesized for evaluation as a myocardial imaging agent. The above product was synthesized by reacting a methanolic solution of NaTcO/sub 4/ with trimethyl phosphite in an inert atmosphere at 100 0 for 30 min. Using the Tc-99 isotope, mg quantities were isolated for full characterization by precipitation from the reaction mixture using sodium tetraphenylborate. Recrystallization from methanol gave crystals of the tetraphenylborate salt. Elemental analyses, Tc-99 and P-31 NMR, mass spectra, X-ray photoelectron spectra, ir and X-ray crystal structure were all consistent with a hexacoordinate octahedral structure of the proposed monocation. The products formed from the Tc-99 isotope and the Tc-99m isotope were shown to be identical by HPLC using simultaneous radiometric and UV detection. The myocardial imaging properties of the title compound were evaluated by rat biodistribution and dog imaging. Five minutes after intravenous administration in rats, 3% dose/gm was in the heart with tissue ratios of heart/blood of 30, heart/liver of 4, heart/lung of 2. These compare to T1-201 values of 6% dose/gm in the heart with tissue ratios of heart/blood of 24, heart/liver of 6, heart/lung of 1. Imaging in an anesthetized dog revealed excellent myocardial uptake with persistent images through a 60 minute period. From these data the hexakis(trimethylphosphite)[Tc-99m]technetium(I) cation was identified as a myocardial imaging agent suitable for further evaluation

  6. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    Science.gov (United States)

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  7. Active and passive vectorization of technetium99m and 188rhenium radiopharmaceuticals for medical imaging and radiotherapy

    International Nuclear Information System (INIS)

    Lepareur, N.

    2003-11-01

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes 186 Re and 188 Re, owing to their ideal properties and their similitude with 99m Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium 99m based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the 188 Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this 188 Re-SSS lipiodol and of its analogue 99m Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  8. Molybdenum-99/technetium-99M generators

    International Nuclear Information System (INIS)

    Morcos, N.A.; Bruno, G.A.; Haney, T.A.

    1981-01-01

    A 99 Mo/sup(99m)Tc generator is described which has an alumina support medium consisting of multiple beds of controlled pH and in which no bed has a pH value higher than the bed preceding it. It is claimed that by using this method low yield problems of such generators can be mitigated. (U.K.)

  9. The preparation of {sup 99m}Tc from {sup 99}Mo-{sup 99m}Tc using Poly-Zirconium Compound (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Laohawilai, S [Isotope Production Div., Office of Atomic Energy for Peace (Thailand)

    1998-10-01

    The process of for providing the {sup 99m}Tc-gel generator followed the protocol that received from Department of Radioisotopes, Tokai Research Establishment, JAERI. Sodium molybdate (molybdenum-99), pH 7 with concentration 20 mg/ml and activity nearly 1 mCi/ml was added into the adsorbent (PZC). The total activity of {sup 99}Mo was about 10 mCi and the heating time was varied from 3-18 hours at 70degC. The properties of the gel were studied for elution profile and elution efficiency. The molybdenum breakthrough in sodium pertechnetate (technetium-99m) was also performed. (author)

  10. Generators of 99Mo-99mTc

    International Nuclear Information System (INIS)

    Robles, A.M.

    1994-01-01

    Between the radioisotopes family pairs we find the 99 Molibdenum - 99m technetium pairs. Such as isotope production,decay and chemical toxic, humid and dry generators,radiation protection handling practice and blinding had been sudied in this work.Tabs

  11. Technetium99m shortage: Practical solutions to manage lack of the radio-isotope in nuclear medicine departments

    International Nuclear Information System (INIS)

    Biechlin-Chassel, M.L.; Francois-Joubert, A.; Bolot, C.; Desruet, M.D.; Bourrel, F.; Pelegrin, M.; Couret, I.; Lao, S.; Quelven, I.

    2010-01-01

    Technetium 99m ( 99m Tc) shortage crisis regularly affect nuclear medicine activity and oblige the community to find solutions in order to perform most of the prescribed exams and avoid systematic substitutions by other non-nuclear medicine techniques. Firstly, some practical solutions can be set up in radiopharmacy departments such as using more than two generators together, realizing fractionated elutions, preparing radiopharmaceuticals with elutions providing from different generators.. Then, it could be interesting to have a reflexion in nuclear medicine departments to convene patients the days when 99m Tc supply is sufficient, to pool some exams or to make substitutions with more available isotopes. (authors)

  12. Technetium 99m SESTAMIBI myocardial perfusion imaging: Comparison between treadmill, dipyridamole and trans-oesophageal atrial pacing 'stress' tests in normal subjects

    International Nuclear Information System (INIS)

    Primeau, M.; Taillefer, R.; Lambert, R.; Essiambre, R.; Honos, G.

    1991-01-01

    The purpose of this study was to determine the blood clearance, myocardial uptake and heart/lung and heart/liver ratios of technetium 99m methoxyisobutylisonitrile ( 99m Tc-SESTAMIBI) following 3 different types of cardiac stimulation in normal subjects: Treadmill stress (STRESS), intravenous administration of dipyridamole (DIP) and trans-oesophageal atrial pacing (TAP). Ten normal volunteers were submitted to 3 injections of 99m Tc-SESTAMIBI (10 mCi/70 kg, separated by an interval of 7 days) following STRESS (standard Bruce protocol), DIP (0.142 mg/kg.min during 4 min) and TAP procedures. Blood samples were collected from 1 to 60 min after each 99m Tc-SESTAMIBI injection. Planar imaging was performed at 5, 30 and 60 min. Blood retention (percentage of injected dose at 1 min) was 56%±4%, 24%±4% and 38%±6% for STRESS, DIP and TAP, respectively (P 99m Tc-SESTAMIBI. (orig.)

  13. Measurement of lymphatic function with technetium-99m-labelled polyclonal immunoglobulin

    International Nuclear Information System (INIS)

    Svensson, W.; Glass, D.M.; Bradley, D.; Peters, A.M.

    1999-01-01

    A reliable method for measuring lymph flow in physiological units would be valuable, especially in conditions in which it is uncertain whether lymph flow is increased or decreased. The requirements of a radiopharmaceutical for such measurement include stable radionuclide labelling and rapid access to lymphatic vessels following tissue injection but no access to blood vessels. A soluble macromolecule is likely to come closest to meeting these requirements. Technetium-99m- labelled human polyclonal immunoglobulin (HIG) was therefore investigated firstly in comparison with 99m Tc-labelled human serum albumin (HSA) in patients undergoing routine lymphoscintigraphy and secondly with respect to injection site in a group of volunteers with post-mastectomy oedema (PMO). Subcutaneous injection of 99m Tc-HIG into the web space of a distal extremity gave images in which lymphatic vessels were more clearly defined compared with images obtained after injection of 99m Tc-HSA. Lymph nodes were also more clearly defined, suggesting specific retention of HIG, possibly through Fc-mediated binding. Peripheral blood sampling showed a delayed arrival in blood of radioactivity after 99m Tc-HIG compared with 99m Tc-HSA, although ultimately, the blood recovery of 99m Tc-HIG was significantly higher (P 99m Tc-HSA. Clearance rates of radioactivity from the injection site were not sinificantly different, however, between the two agents. In patients with PMO, web space injection of 99m Tc-HIG gave excellent images of normal lymphatic vessels, of lymph nodes and of abnormal lymph drainage such as dermal backflow in swollen arms. In contrast, neither lymphatic vessels nor lymph nodes were visualised after injection into the skin of the dorsum of the distal forearm. Although there was no difference in clearance rates from the injection sites between normal and swollen arms with either agent in PMO, clearance was significantly faster following injection into the web space (0.11% per minute for

  14. Technetium-99m labelled antimicrobial peptides discriminate between bacterial infections and sterile inflammations

    International Nuclear Information System (INIS)

    Welling, M.M.; Pauwels, E.K.J.; Paulusma-Annema, A.; Nibbering, P.H.; Balter, H.S.

    2000-01-01

    The aim of this study was to select technetium-99m labelled peptides that can discriminate between bacterial infections and sterile inflammations. For this purpose, we first assessed the binding of various 99m Tc-labelled natural or synthetic peptides, which are based on the sequence of the human antimicrobial peptide ubiquicidin (UBI) or human lactoferrin (hLF), to bacteria and to leucocytes in vitro. In order to select peptides that preferentially bind to bacteria over host cells, radiolabelled peptides were injected into mice intraperitoneally infected with Klebsiella pneumoniae (K. pneumoniae) and the amount of radioactivity associated with the bacteria and with the leucocytes was quantitated. The next phase focussed on discrimination between bacterial infections and sterile inflammatory processes using 99m Tc-labelled peptides in mice intramuscularly infected with various bacteria (e.g. multi-drug-resistant Staphylococcus aureus) and in animals that had been injected with lipopolysaccharides (LPS) of bacterial origin to create a sterile inflammatory process. Also, we studied the distribution of 99m Tc-labelled UBI 29-41 and UBI 18-35 in rabbits having an experimental thigh muscle infection with K. pneumoniae and in rabbits injected with LPS. Based on the results of our in vitro and in vivo binding assays, two peptides, i.e. UBI 29-41 and UBI 18-35, were selected as possible candidates for infection imaging. The radiolabelled peptides can detect infections with both gram-positive and gram-negative bacteria in mice as early as 5-30 min after injection, with a target-to-non-target (T/NT) ratio between 2 and 3; maximum T/NT ratios were seen within 1 h after injection. In rabbits, high T/NT ratios (>5) for 99m Tc-labelled UBI 29-41 were observed from 1 h after injection. No accumulation of the selected 99m Tc-labelled UBI-derived peptides was observed in thighs of mice and rabbits previously injected with LPS. Scintigraphic investigation into the biodistribution of

  15. Technetium-99m labelled antimicrobial peptides discriminate between bacterial infections and sterile inflammations

    Energy Technology Data Exchange (ETDEWEB)

    Welling, M.M.; Pauwels, E.K.J. [Dept. of Radiology, Leiden University Medical Center (LUMC) (Netherlands); Paulusma-Annema, A.; Nibbering, P.H. [Dept. of Infectious Diseases, Leiden University Medical Center (Netherlands); Balter, H.S. [Centro Investigaciones Nucleares, Univ. of the Republic Uruguay, Montevideo (Uruguay)

    2000-03-01

    The aim of this study was to select technetium-99m labelled peptides that can discriminate between bacterial infections and sterile inflammations. For this purpose, we first assessed the binding of various {sup 99m}Tc-labelled natural or synthetic peptides, which are based on the sequence of the human antimicrobial peptide ubiquicidin (UBI) or human lactoferrin (hLF), to bacteria and to leucocytes in vitro. In order to select peptides that preferentially bind to bacteria over host cells, radiolabelled peptides were injected into mice intraperitoneally infected with Klebsiella pneumoniae (K. pneumoniae) and the amount of radioactivity associated with the bacteria and with the leucocytes was quantitated. The next phase focussed on discrimination between bacterial infections and sterile inflammatory processes using {sup 99m}Tc-labelled peptides in mice intramuscularly infected with various bacteria (e.g. multi-drug-resistant Staphylococcus aureus) and in animals that had been injected with lipopolysaccharides (LPS) of bacterial origin to create a sterile inflammatory process. Also, we studied the distribution of {sup 99m}Tc-labelled UBI 29-41 and UBI 18-35 in rabbits having an experimental thigh muscle infection with K. pneumoniae and in rabbits injected with LPS. Based on the results of our in vitro and in vivo binding assays, two peptides, i.e. UBI 29-41 and UBI 18-35, were selected as possible candidates for infection imaging. The radiolabelled peptides can detect infections with both gram-positive and gram-negative bacteria in mice as early as 5-30 min after injection, with a target-to-non-target (T/NT) ratio between 2 and 3; maximum T/NT ratios were seen within 1 h after injection. In rabbits, high T/NT ratios (>5) for {sup 99m}Tc-labelled UBI 29-41 were observed from 1 h after injection. No accumulation of the selected {sup 99m}Tc-labelled UBI-derived peptides was observed in thighs of mice and rabbits previously injected with LPS. Scintigraphic investigation

  16. Technetium{sup 99m} shortage: Practical solutions to manage lack of the radio-isotope in nuclear medicine departments; Penurie de technetium{sup 99m}: des pistes pratiques pour gerer les periodes de crise dans les services de medecine nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Biechlin-Chassel, M.L. [Radiopharmacie, service de pharmacie, centre hospitalier de Chambery, 73 - Chambery (France); Francois-Joubert, A. [Service de medecine nucleaire, centre hospitalier de Chambery, 73 - Chambery (France); Bolot, C. [Service de radiopharmacie, service pharmaceutique, centre de medecine nucleaire, groupement hospitalier Est, 69 - Bron (France); Desruet, M.D. [Radiopharmacie, service de medecine nucleaire, CHU de Grenoble, 38 - Grenoble (France); Bourrel, F. [Services de pharmacie et medecine nucleaire, centre hospitalier d' Avignon, 84 - Avignon (France); Pelegrin, M. [Institut de recherche en cancerologie (IRCM), 34 - Montpellier (France); Inserm U896, universite Montpellier 1, 34 - Montpellier (France); CRLC Val d' Aurelle Paul-Lamarque, 34 - Montpellier (France); Couret, I. [Service de medecine nucleaire, hopital Lapeyronie, 34 - Montpellier (France); Lao, S. [Service de medecine nucleaire, CHU Hopital de l' Archet, 06 - Nice (France); Quelven, I. [Faculte de medecine, 87 - Limoges (France)

    2010-11-15

    Technetium{sup 99m} ({sup 99m}Tc) shortage crisis regularly affect nuclear medicine activity and oblige the community to find solutions in order to perform most of the prescribed exams and avoid systematic substitutions by other non-nuclear medicine techniques. Firstly, some practical solutions can be set up in radiopharmacy departments such as using more than two generators together, realizing fractionated elutions, preparing radiopharmaceuticals with elutions providing from different generators.. Then, it could be interesting to have a reflexion in nuclear medicine departments to convene patients the days when {sup 99m}Tc supply is sufficient, to pool some exams or to make substitutions with more available isotopes. (authors)

  17. Dynamic SPECT of the brain using a lipophilic technetium-99m complex, PnAO

    DEFF Research Database (Denmark)

    Holm, S; Andersen, A R; Vorstrup, S

    1985-01-01

    m PnAO was injected i.v. as a bolus of 15 to 25 mCi. The distribution was followed over 10-sec intervals using a highly sensitive, rapidly rotating SPECT (Tomomatic 64) and compared to 133Xe flow maps. Upon arrival of the PnAO bolus to the brain, a high uptake was found in brain tissue with high......The lipophilic 99mTc-labeled oxime propylene amine oxime (PnAO) should, according to recent reports behave like 133Xe in the human brain. This study compares SPECT images of the two tracers in six subjects: four stroke cases, one transitory ischemic attack case and one normal subject. Technetium-99......AO has a high yet incomplete brain extraction yielding a flow dominated initial distribution with limitations mentioned....

  18. Technetium-99 labelling of DD-3B6/22 antifibrin monoclonal antibody fragmented Fab' for thrombus imaging

    International Nuclear Information System (INIS)

    Lee, F-T.; Boniface, G.R.; Lambrecht, R.M.; Rylatt, D.B.; Bundesen, P.G.

    1993-01-01

    The antifibrin DD-3B6/22 monoclonal antibody Fab' fragment, a murine immunoglobulin, IgG3, has been labelled with technetium-99m ( 99mTc ) via a transchelation reaction, to specific activity in excess of 30 mCi/mg protein. The radiolabelling of Fab' was dependent on time, temperature, pH, antibody concentrations and nature intermediary transchelation complex used. The resultant radioconjugate was stable in vitro and in vivo. Blood clearance of 99m Tc-Fab' in rat followed two compartment kinetics with the half time of the fast phase being 0.5 h. The main route of excretion was via the kidneys with little uptake indicated by other tissues. The results suggest that the inherent specificity of the antibody, small molecular size, rapid plasma clearance, high specific radioactivity, together with the physical properties of the 99m Tc label, combine to make this labelled monoclonal antibody (MoAb), potentially suitable as a radiopharmaceutical for the scintigraphic detection of thrombi in humans. 17 refs., 3 tabs., 5 figs

  19. Phantom evaluation of simultaneous thallium-201/technetium-99m acquisition in single-photon emission tomography

    International Nuclear Information System (INIS)

    Cao Zongjian; Chen, C.C.; Maunoury, C.; Holder, L.E.; Abraham, T.C.; Tehan, A.

    1996-01-01

    This study investigated downscatter effects in cardiac single-photon emission tomographic studies with simultaneous thallium-201/technetium-99m acquisition, and evaluated a previously proposed subtraction technique for downscatter compensation. Ten studies were carried out with different defect sizes and locations and varying activity distributions using four energy windows: 70±10% keV, 140±10% keV, 100±10% KeV, and 103±16% keV. The subtraction technique used the 100- or 103-keV data to remove scattered 99m Tc counts from the 70-keV data. The size and contrast of infarcts in the dual-isotope 70-keV image were artificially decreased compared to those in the 140-keV image, caused by scattered 99m Tc counts that were comparable to the primary 201 Tl counts in the 70-keV window. The subtraction technique produced larger defects and more heterogeneous activity in the myocardial wall in dual-isotope 70-keV images compared to the corresponding 201 Tl-only images. These artifacts were caused by the markedly different spatial distributions of scattered 99m Tc counts in the 100-keV (or 103-keV) window as compared with the 70-keV window. It is concluded that scattered 99m Tc photons may cause overestimation of ischemia and myocardial viability in simultaneous dual-isotope patient studies. The proposed subtraction technique was inaccurate and produced image artifacts. Adequate downscatter compensation methods must be developed before applying simultaneous 201 Tl/ 99m Tc acquisition in clinical practice. (orig.). With 6 figs., 3 tabs

  20. Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease

    International Nuclear Information System (INIS)

    Sullo, P.; Cuocolo, A.; Nicolai, E.; Cardei, S.; Nappi, A.; Squame, F.; Covelli, E.M.; Pace, L.; Salvatore, M.

    1996-01-01

    The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99m Tc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (≥50% luminal stenosis) (n=50) had an abnormal 99m Tc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall senstivity, specificity and diagnostic accuracy in the detection of individual stenosed vissels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P 75%). (orig.)

  1. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  2. Active and passive vectorization of technetium{sup 99m} and {sup 188}rhenium radiopharmaceuticals for medical imaging and radiotherapy; Vectorisations active et passive de radiopharmaceutiques du technetium-99m et du rhenium-188 pour l'imagerie medicale et la therapie

    Energy Technology Data Exchange (ETDEWEB)

    Lepareur, N

    2003-11-15

    Research for new molecules for nuclear medicine is a field in constant development. Over the past few years, development of new radiopharmaceuticals for radiotherapy has renewed interest for rhenium chemistry. Indeed, its two isotopes {sup 186}Re and {sup 188}Re, owing to their ideal properties and their similitude with {sup 99m}Tc, which is widely used as a radiotracer for diagnostic imaging, seem very promising for the preparation of radiopharmaceuticals. In the first part of this manuscript, the synthesis of rhenium and technetium-99 complexes, [M(RPhCS3)2(RPhCS2)] (M = Re, Tc), is described. The preparation of technetium{sup 99m} based radiopharmaceuticals, analogues to the pondered complexes, is also described. The stability/reactivity of these complexes has been studied by exchange reactions with potential ligands, specially dithiocarbamates, and also by UV-visible absorption spectroscopy and thermogravimetry. The reactivity of the complexes towards dithiocarbamates leads to the possibility to bind biomolecules to the metallic core, via the dithiocarbamate moiety. This method represents a potential alternative to current ones using the so-called bifunctional approach. In the second part of this manuscript, a new kit formulation for the {sup 188}Re labeling of lipiodol is described, using a complex analogous to those described in the previous part. The labeled oil is a potential cure for hepatocellular carcinoma. The in vitro and in vivo stability of this {sup 188}Re-SSS lipiodol and of its analogue {sup 99m}Tc-SSS lipiodol has been studied, and also their in vivo behavior in healthy pigs. This study has shown the quasi-exclusive hepatic fixation of the radiopharmaceutical, and has proven its good stability. Its selectivity for tumors remains to be shown before trying it on humans. (author)

  3. Effect of EHDP on calcium accumulation and technetium-99m pyrophosphate uptake in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Buja, L.M.; Tofe, A.J.; Parkey, R.W.; Francis, M.D.; Lewis, S.E.; Kulkarni, P.V.; Bonte, F.J.; Willerson, J.T.

    1981-01-01

    Ethane-l-hydroxy-1,1-diphosphonate (EHDP) inhibits bone mineral growth. This study was performed to test the hypothesis that EHDP would interfere with the process of calcium uptake and deposition in evolving myocardial infarction and thereby influence other parameters, including technetium-99m pyrophosphate (Tc-99m PYP) uptake and scintigraphic visualization of the infarcts. Permanent occlusion of the left anterior descending coronary artery (LAD) was produced in beagles. In seven dogs, serum EHDP was maintained at 10-15 μg/ml for 24 hours by continuous i.v. infusion, and seven control dogs were infused with saline. The Tc-99m PYP was infected 2 hours before sacrifice. EHDP-treated dogs showed a mild decrease (20%) in mean calcium content of infarcted myocardium (102.4 +/- 6.4 μg [+/- SEM] per gram wet weight [n = 51] vs 126.7 +/- 9.5 [n = 49] [p -3 ] [n = 46] vs 28.9 +/- 4.3 [n = 46] [p < 0.005]) and a marked decrease (65%) in infarct-to-normal ratio (6.1 +/- 0.9 [n = 6] vs 15.9 +/- 3.7 [n = 6] [p < 0.05]). Positive relationships were demonstrated between myocardial Tc-99m PYP and calcium levels in the EHDP-treated dogs (r = 0.69) and the control dogs (r = 0.77). Infarct size and regional myocardial blood flow changes were similar in the EHDP-treated and control dogs. The average grade (0-4+) of the Tc-99m PYP myocardial scintigrams for infarcts greater than 3.5 g was 2.4 +/- 0.2 for control dogs and 1.1 +/- 0.4 for EHDP-treated dogs (p < 0.05). Thus, EHDP infusion at the dose tested produced a mild decrease in calcium accumulation in canine infarcts; however, it produced a greater reduction in Tc-99m PYP uptake in the infarcts

  4. Diagnosis of acute cholecystitis using hepatobiliary scan with technetium-99m PIPIDA

    International Nuclear Information System (INIS)

    Bennett, M.T.; Sheldon, M.I.; dos Remedios, L.V.; Weber, P.M.

    1981-01-01

    Sixty patients were evaluated for acute abdominal pain using technetium-99m PIPIDA hepatobiliary imaging. The sensitivity of the test was 90.6 percent in all patients and the accuracy was 93.3 percent. In the evaluation of acutely ill patients with right upper quadrant pain, fever, nausea and vomiting, hepatobiliary imaging with PIPIDA is the preferred test for diagnosing acute cholecystitis. If the test is positive, disease of the gallbladder and probably acute cholecystitis are present. Early operation can proceed if desirable. If the test is negative and the bilirubin level is less than 5.0 mg/dl, acute cholecystitis is not present. In such cases conservative treatment is appropriate, and follow-up tests should be performed to evaluate the possibility of chronic cholecystitis. When the bilirubin level exceeds 5.0 mg/dl, the test is often indeterminate

  5. Technetium-99m sestamibi imaging in paediatric neuroblastoma and ganglioneuroma and its relation to P-glycoprotein

    International Nuclear Information System (INIS)

    Moerloose, B. de; Dhooge, C.; Benoit, Y.; Laureys, G.; Wiele, C. van de; Dierckx, R.A.; Philippe, J.; Speleman, F.

    1999-01-01

    Imaging with technetium-99m sestamibi offers a non-invasive approach to detect the presence of functional P-glycoprotein (Pgp), one of the major causes of multidrug resistance, in human malignancies. A clinical role for Pgp has been suggested in the subpopulation of primary neuroblastoma without amplification of the proto-oncogene MYCN. We wanted to evaluate the usefulness of 99m Tc-sestamibi scintigraphy in the screening of neural crest tumours for the presence of Pgp. In ten children suffering from MYCN-negative neuroblastoma, ganglioneuroblastoma or ganglioneuroma, 99m Tc-sestamibi imaging was performed at initial diagnosis. All patients underwent planar imaging 20-30 min and 3.5-4 h after intravenous injection of 740 MBq/1.73 m 2 99m Tc-sestamibi. Tumour to normal tissue ratios, as well as washout rates, were determined and compared with in vitro flow cytometric analysis of Pgp expression and function. Pgp expression was analysed flow cytometrically with the monoclonal antibodies 4E3 and MRK16, and Pgp function was evaluated by means of rhodamine 123 uptake and efflux either in the absence or in the presence of the Pgp inhibitor verapamil. In nine of ten patients, we found that the intratumoral 99m Tc-sestamibi activity was comparable to the background activity, which might be suggestive of Pgp presence. This was confirmed flow cytometrically in all but one patient. 99m Tc-sestamibi enhancement was seen in the primary tumour and the bone marrow metastases of one of the ten patients, and this result was concordant with a negative Pgp status. The findings presented suggest that 99m Tc-sestamibi imaging results might correlate with the presence of functional Pgp in neural crest tumours without MYCN amplification. (orig.)

  6. Technetium-99m sestamibi imaging in paediatric neuroblastoma and ganglioneuroma and its relation to P-glycoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Moerloose, B. de; Dhooge, C.; Benoit, Y.; Laureys, G. [Department of Pediatrics, University Hospital Gent (Belgium); Wiele, C. van de; Dierckx, R.A. [Department of Nuclear Medicine, University Hospital Gent (Belgium); Philippe, J. [Department of Clinical Chemistry, Microbiology and Immunology, University Hospital Gent (Belgium); Speleman, F. [Department of Medical Genetics, University Hospital Gent (Belgium)

    1999-04-29

    Imaging with technetium-99m sestamibi offers a non-invasive approach to detect the presence of functional P-glycoprotein (Pgp), one of the major causes of multidrug resistance, in human malignancies. A clinical role for Pgp has been suggested in the subpopulation of primary neuroblastoma without amplification of the proto-oncogene MYCN. We wanted to evaluate the usefulness of {sup 99m}Tc-sestamibi scintigraphy in the screening of neural crest tumours for the presence of Pgp. In ten children suffering from MYCN-negative neuroblastoma, ganglioneuroblastoma or ganglioneuroma, {sup 99m}Tc-sestamibi imaging was performed at initial diagnosis. All patients underwent planar imaging 20-30 min and 3.5-4 h after intravenous injection of 740 MBq/1.73 m{sup 2} {sup 99m}Tc-sestamibi. Tumour to normal tissue ratios, as well as washout rates, were determined and compared with in vitro flow cytometric analysis of Pgp expression and function. Pgp expression was analysed flow cytometrically with the monoclonal antibodies 4E3 and MRK16, and Pgp function was evaluated by means of rhodamine 123 uptake and efflux either in the absence or in the presence of the Pgp inhibitor verapamil. In nine of ten patients, we found that the intratumoral {sup 99m}Tc-sestamibi activity was comparable to the background activity, which might be suggestive of Pgp presence. This was confirmed flow cytometrically in all but one patient. {sup 99m}Tc-sestamibi enhancement was seen in the primary tumour and the bone marrow metastases of one of the ten patients, and this result was concordant with a negative Pgp status. The findings presented suggest that {sup 99m}Tc-sestamibi imaging results might correlate with the presence of functional Pgp in neural crest tumours without MYCN amplification. (orig.) With 4 figs., 2 tabs., 44 refs.

  7. Assessment of the accumulation of technetium-99m labelled leukocytes in the treatment of the infections of vascular prosthesis

    International Nuclear Information System (INIS)

    Pupka, A.; Kaluza, G.; Skora, J.; Szyber, P.; Rynowiecka, M.

    2003-01-01

    The purpose of this is to evaluate the accumulation of technetium-99m-labelled leukocytes after change of vascular, dacron and infected prosthetic graft in arterial homo grafts harvested from multiorgan-procurement - with own computer program. In this paper 11 cases of aorto-ilio-femoral graft infection treated by the replacement of infected prosthesis with fresh, bifurcated, arterial homografts is presented. In all patients clinical investigations revealed vascular prosthesis infection with the rupture of vascular anastomoses between the prosthesis' branch and wall of artery that resulted with hemorrhage. The Duplex- Doppler ultrasound and the scintigraphy with use of technetium-labeled leucocytes were used in the diagnostic trial of infection and of the healing process of the arterial homografts.The area of the accumulation of 99m Tc labelled leukocytes was evaluated with own computer programs. Positive clinical effect was obtained in all patients.The regression of infection after in situ replacement of the synthetic prosthesis with homograft was presented with the scintigraphic examination: in these patients the area of leukocytes accumulation decreased from 34±3 cm 2 to 9±2cm 2 . The use of scintigraphy with 99m Tc labelled leukocytes to evaluate the healing process of the arterial homografts in therapy of the prosthetic graft is a the accumulation of leucocytes is facilitation in the monitoring of regression of infection. (author)

  8. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  9. Technetium-99m labeled somatostatin and analogs: synthesis, characterization and in vivo evaluation

    International Nuclear Information System (INIS)

    Amartey, J.K.

    1993-01-01

    Technetium-99m complexes of somatostatin and analogs were synthesized following the introduction of sulfhydryl groups with 2-iminothiolane (Traut's Reagent). In rats the complex was taken up by the liver, kidneys, adrenals, lungs and the pancreas. Analysis of urine samples of treated rats showed that the radiochemicals have reasonably good in vivo stability. This implies that the complexes may be potentially useful for biochemical characterization of somatostatin receptors and also in scintigraphic detection of somatostatin receptor positive tumors, especially for metastatic deposits in patients on somatostatin therapy. (Author)

  10. Technetium-99m scintigraphy associated with spondylolysis of the lumbar spine in children

    International Nuclear Information System (INIS)

    Kubota, Wataru; Sudo, Nariomi; Nakazima, Kiyonori; Nakamura, Mitsutaka

    1987-01-01

    Eight children with spondylolysis, aged from 10 to 18 years of age, underwent bone scanning with technetium-99m methylene diphosphonic acid. Radioisotope (RI) uptake was significantly observed in the site marked by the separation of the pars interarticularis, compared with the other sites between the articular processes. This showed the increase in metabolic activity of bones, providing supplementary information in the initial diagnosis. At the completion of conservative treatment, RI uptake decreased, being seemingly attributable to the improvement of subjective symptoms. Bone scanning may, however, be unhelpful in detecting synostosis. (Namekawa, K.)

  11. Technetium-99m scintigraphy associated with spondylolysis of the lumbar spine in children

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, W.; Sudo, N.; Nakazima, K.; Nakamura, M.

    1987-02-01

    Eight children with spondylolysis, aged from 10 to 18 years of age, underwent bone scanning with technetium-99m methylene diphosphonic acid. Radioisotope (RI) uptake was significantly observed in the site marked by the separation of the pars interarticularis, compared with the other sites between the articular processes. This showed the increase in metabolic activity of bones, providing supplementary information in the initial diagnosis. At the completion of conservative treatment, RI uptake decreased, being seemingly attributable to the improvement of subjective symptoms. Bone scanning may, however, be unhelpful in detecting synostosis.

  12. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    International Nuclear Information System (INIS)

    Erdogan, Zeynep; Silov, Güler; Özdal, Aysegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi ( 99m Tc MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of 99m Tc MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. (author)

  13. Determination of technetium-99 from complex matrix

    International Nuclear Information System (INIS)

    Lixiong Wang; Lei Tang; Tongzai Yang; Yanqiu Yang; Liang Yang

    2013-01-01

    This paper reports an approach that can be used for efficient separation and determination of 99 Tc (as pertechnetate) after contamination of the environment by nuclear materials. The samples were decomposed by fusion in a mixture of potassium hydroxide and potassium nitrate. After fusion, technetium remains as the pertechnetate anion (TcO 4 - ). The technetium was isolated from the sample by technique combining solvent extraction, anion exchange, then, again, solvent extraction. After separation, 99 Tc was measured by isotope-dilution mass spectrometry with 97 Tc as spike. This method yielded nanogram detection limits for 99 Tc. (author)

  14. Preliminary studies of EDDA-tricine-HYNIC-[Tyr3]octreotide labelled with Technetium-99m: radiopharmaceutical development for the diagnostic of neuroendocrine tumours

    International Nuclear Information System (INIS)

    Melero, Laura T.U.H.; Muramoto, Emiko; Arauho, Elaine Bortoleti de

    2007-01-01

    The use of labelled molecules with high specificity for an organ or receptor in scintigraphy, generate good local images of these specific receptors that are expressed for the biomolecule in question, minimizing the exposition of other organs. Small labelled peptides have showed a big potential for tumors image and other diseases in nuclear medicine. The octreotide was the first somatostatin synthetic analog introduced in clinical use in the localization of tumours with superexpression of somatostatin receptors which is a hundred times over in tumors cells that in normal cells. It did many attempts to development of a somatostatin analog labelled with 99mTc utilizing a variety of chelant systems until development the HYNIC-D-Phe1-Tyr3-octreotide, using tricine and EDDA as coligands, showing maintenance of in vivo affinity and promising of biodistribution in animals with induced tumours. This work involved the development of a 99mTc (technetium-99m) radiopharmaceutical based in a somatostatin peptide derivative (Tyr3-octreotide, TOC), with HYNIC chelating group, to be applied in the diagnostic of neuroendocrine tumors in nuclear medicine. Quality control methodologies to be applied in determination of the radiochemical purity of the labelled compound was also studied as well the biodistribution in normal Swiss mouse. The 99mTc-HYNIC-TOC was obtained in high radiochemical yield. Biodistribution studies suggests the potential of this radiopharmaceutical in the diagnostic of neuroendocrine tumours. (author)

  15. Technetium 99m-labeled annexin v scintigraphy of platelet activation in vegetations of experimental endocarditis

    International Nuclear Information System (INIS)

    Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D.; Rouzet, F.; Sarda-Mantel, L.; LeGuludec, D.; Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D.; Hernandez, M.D.; Louedec, L.; Michel, J.B.; Hervatin, F.; Lefort, A.; Fantin, B.; Duval, X.; Duval, X.; Hernandez, M.D.

    2008-01-01

    Background: The pathophysiology of infective endocarditis involves a pathogen/host tissue interaction, leading to formation of infected thrombotic vegetations. Annexin V is a ligand of phosphatidyl-serines exposed by activated platelets and apoptotic cells. Because vegetations are platelet-fibrin clots in which platelet pro-aggregant activity is enhanced by bacterial colonization, we investigated the ability of annexin V labeled with technetium 99m Tc ( 99m Tc-ANX) to provide functional imaging of these vegetations in experimental models of infective endocarditis. This ability was assessed in rabbits and rats because of the different interest of these 2 species in preclinical analysis. Methods and Results: Non-bacterial thrombotic endocarditis was induced with the use of a catheter left indwelling through the aortic or tricuspid valve, and animals were injected with either a bacterial inoculum or saline. Scintigraphic investigations were performed 5 days later and showed a higher 99m Tc-ANX uptake by vegetations in infected versus non-infected animals (ratio,1.3 for in vivo acquisitions and 2 for autoradiography; P ≤ 0.0001 for all), whereas no significant uptake was present in controls. Right-sided endocarditis was associated with pulmonary uptake foci corresponding to emboli. Histological analysis of vegetations showed a specific uptake of 99m Tc-ANX at the interface between circulating blood and vegetation. In parallel, underlying myocardial tissue showed myocyte apoptosis and mucoid degeneration, without extracellular matrix degradation at this stage. Conclusions: 99m Tc-ANX is suitable for functional imaging of platelet-fibrin vegetations in endocarditis, as well as embolic events. 99m Tc-ANX uptake reflects mainly platelet activation in the luminal layer of vegetations. This uptake is enhanced by bacterial colonization. (authors)

  16. Single photon emission computed tomography of technetium-99m tetrofosmin myocardial perfusion imaging in patients with systemic lupus erythematosus-A preliminary report

    International Nuclear Information System (INIS)

    Lin, Jen-Jhy; Hsu, Hsiu-Bao; Sun, Shung-Shung; Kao, Chia-Hung; Ho, Shung-Tai

    2003-01-01

    The purpose of this study was to evaluate the utility of single-photon emission computed tomography (SPECT) of technetium-99m tetrofosmin (Tc-99m TF) myocardial perfusion imaging to detect myocardial involvement in patients with systemic lupus erythematosus (SLE). Three groups of subjects-group 1: 25 SLE female patients with non-specific cardiac symptoms and signs, group 2: 25 female SLE patients without any cardiac symptoms and signs, and group 3: 25 female healthy controls-were evaluated by comparing rest and dipyridamole-stress Tc-99m TF myocardial perfusion SPECT. Tc-99m TF myocardial perfusion SPECT revealed perfusion defects in 88% and 40% of the cases in groups 1 and 2, respectively. However, no cases in group 3 demonstrated myocardial perfusion defects. Tc-99m TF myocardial perfusion SPECT is a useful noninvasive imaging modality to detect cardiac involvement in SLE patients with or without cardiac symptoms and signs. (author)

  17. Detection of homing-in of stem cells labeled with technetium-99m hexamethylpropyleneamine oxime in infarcted myocardium after intracoronary injection

    International Nuclear Information System (INIS)

    Patel, Chetan D; Agarwal, Snehlata; Seth, Sandeep; Mohanty, Sujata; Aggarwal, Himesh; Gupta, Namit

    2014-01-01

    Bone marrow stem cells having myogenic potential are promising candidates for various cell-based therapies for myocardial disease. We present here images showing homing of technetium-99m (Tc-99m) hexamethylpropyleneamine oxime (HMPAO) labeled stem cells in the infarcted myocardium from a pilot study conducted to radio-label part of the stem cells in patients enrolled in a stem cell clinical trial for recent myocardial infarction

  18. Technetium-99m labeled antisense oligonucleotide-noninvasive tumor imaging in mice

    International Nuclear Information System (INIS)

    Qin, G.M.; Zhang, Y.X.; An, R.; Gao, Z.R.; Cao, W.; Cao, G.X.; Hnatowich, D.J.

    2002-01-01

    as early as 30 minutes and reached a saturation value at 4 hour. The accumulation of radioactivity in the tumor was lower at all time points in animals receiving the blocking oligonucleotides or sense probes. All images obtained with 99m Tc-MAG3-c-myc antisense probes showed specific accumulation of radioactivity at the site of tumor. Positive imaging was not obtained in case of control group. Conclusion: The 99m Tc labeled antisense probe may provide a sensible and specific tool for noninvasive imaging of c-myc oncogene mRNA for a variety of malignant tumors at an earlier stage

  19. Scintigraphic detection of 'yo-yo' phenomenon in incomplete ureteric duplication

    International Nuclear Information System (INIS)

    Chu, Winnie C.W.; Chan, Kam-wing; Metreweli, Constantine

    2003-01-01

    'Yo-yo' reflux in an incompletely duplicated renal system was demonstrated on 99m Tc-mercaptoacetyltriglycine (MAG3) renal scintigraphy in a 7-year-old girl presenting with low-grade fever and pyelonephritis. Incomplete duplication and a bifid renal pelvis, which may be seen in up to 4% of the North American population, occasionally causes symptoms because of recurrent urinary tract infection or loin pain. 99m Tc-MAG3 renal scintigraphy can demonstrate 'yo-yo' reflux in patients with incomplete renal duplication and should be considered in cases with unexplained loin pain, even if 99m Tc-dimercaptosuccinic acid (DMSA) renal scintigraphy is normal. (orig.)

  20. A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation

    International Nuclear Information System (INIS)

    Warren-Forward, H.; Cardew, P.; Smith, B.; Clack, L.; McWhirter, K.; Johnson, S.; Wessel, K.

    2007-01-01

    Nuclear medicine technologists (NMTs) have the highest effective doses of radiation among medical workers. With increase in the use of lightweight materials in diagnostic radiography, the aim was to compare the effectiveness of lead and lightweight aprons in shielding from 99m-Technetium ( 99m Tc) gamma rays. The doses received from a scattering phantom to the entrance, 9 cm depth and exit of a phantom were measured with LiF:Mg, Cu, P thermoluminescent dosemeters (TLDs). Doses and spectra were assessed without no shielding, with 0.5-mm lead and lightweight aprons. The lead and lightweight aprons decreased entrance surface doses by 76 and 59%, respectively. The spectral analysis showed that the lightweight apron provided better dose reduction at energies 99m Tc labelled radiopharmaceutical. (authors)

  1. Supranormal differential renal function in an obstructed kidney demonstrated on 99MTc-mercaptoacetyltriglycine (MAG3) diuresis renography - is it real or an artifact?

    International Nuclear Information System (INIS)

    Wegner, E.A.; Eagle, B.; Mitchell, G.; Rossleigh, M.A.

    2003-01-01

    Full text: Diuresis renography has been used extensively as a noninvasive method of estimating differential renal function (DRF), which may determine patient management. There has been controversy as to whether the phenomenon of supranormal DRF (>55%) in an obstructed kidney exists and the significance of this finding. A case study of a child with supranormal renal function is presented and the impact of different background regions on DRF calculations is demonstrated. Serial MAG3 studies were performed at ages 3 weeks, 2 and 10 months on a male with an antenatal diagnosis of right hydronephrosis. A weight adjusted dose of MAG3 was given simultaneously with frusemide (1mg/kg). DRF was calculated at 1.5-2.5 minutes following tracer administration. Background correction regions were drawn at the lower pole of each kidney. Supranormal DRF (61%) of the hydronephrotic kidney was demonstrated on the baseline study. There was deterioration in scan appearances and persistent supranormal DRF (64%) on the follow up study and the patient proceeded to pyeloplasty. The post-operative study demonstrated an improvement in scan findings and DRF returned to normal (55%). When suprarenal and perirenal background regions were used, supranormal DFR values were not obtained. Suprarenal background - 47%, 50%, 55% and perirenal background - 55%, 57% and 54% DRF on sequential studies. Review of the literature provides conflicting evidence as to the significance and even existence of this phenomenon. The location of background correction regions appears to influence DRF results. This occurs particularly when MAG3 is used, because of physiological uptake in the liver. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  2. Technetium compounds

    International Nuclear Information System (INIS)

    Murphy, C.A. de; Ferro F, G.

    2003-01-01

    The first radiopharmaceuticals of 99m Tc, also call of 'first generation' as colloids, aggregates and simple complexes were developed with relative easiness without it was necessary a wide understanding of its chemical structure. In the radiopharmaceuticals of 'second generation' were included those derived of the HIDA for hepatobiliary images, MAG3 and EC for images of tubular renal de purification, HMPAO and ECD for images of cerebral perfusion and MIBI and tetrofosmin for images of heart perfusion, that which implies a bigger demand in terms of the chemical knowledge. At the moment, we can affirm that the future of the radiopharmaceuticals of 99m Tc is based on the use of small and relevant biomolecules with high biological activity that allow the visualization in vivo of specific receiving sites and/or its expression in diverse pathologies. It is for it that with the 'third generation' is necessary a wide one knowledge of the chemistry of the technetium that allows the design and characterization of highly specific bio complexes. In this book, although focused mainly to the chemistry of the Tc, a brief revision is also presented on the main biologically active molecules that, coordinated the 99m Tc, present a high recognition In vivo for specific receivers. (Author)

  3. Blood cell labeling with technetium-99m, (3)

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Akizuki, Tsuyoshi; Tanaka, Tetsugoro; Yui, Tokuo; Miura, Nobuo

    1978-01-01

    Spleen scintigraphy was performed by the use of sup(99m)Tc-labeled red blood cells which were prepared with a kit (TCK-11 produced by CIS) and were damaged by heating for 15 min at 49.0 +- 0.5 0 C or damaged chemically by treating with bromomerculi hydroxy propane (BMHP) 1.5 mg/2 ml of blood. The images obtained by scanner and scintillation camera were both favorable, and the author decided that this method is applicable to clinical spleen scintigraphy. The spleen scintigraphy with sup(99m)Tc-labeled red blood cells has many merits such as it gives a less exposure dose to patients under the examination so that it makes capable of repeated examinations, it uses a less volume of blood for labeling, and the procedure is not so complicated compared with the usual methods of 51 Cr-heating or 203 Hg- (or 197 Hg-) MHP. Therefore, this method is preferable to the other usual methods. (Ueda, J.)

  4. Effect of Radioactivity of Technetium-99m on the Autosterilization Process of non-sterile Tetrofosmin Kits

    Directory of Open Access Journals (Sweden)

    Widyastuti Widyastuti

    2017-03-01

    Full Text Available Technetium-99m labeled radiopharmaceutical is commonly used in nuclear medicines as a diagnostic agent, by mixing the sterile kit with Tc-99m. Manufacturing of kits requires an aseptic facility which need to be well designed and maintained according to cGMP, since mostly kits can not be terminally sterilized. Radiopharmaceuticals as pharmaceuticals containing radionuclide is assumed to have an autosterilization property, but correlation between radioactivity and capability of killing microorganisms has to be studied so far. The aim of this study is to investigate the effect of radioactivity on the autosterilization process of radiopharmaceuticals. The study was carried out by adding Tc-99m of various radioactivity into non-sterile tetrofosmin kits, then the samples were tested for sterility. Sterile tetrofosmin kit and non-sterile kit with no Tc-99m added will be used as a negative control and positive control respectively. The sterility was tested using standard direct inoculation method, by inoculating samples in culture media for both bacteria and fungi and observing qualitatively within 14 days. The results showed that the samples with radioactivity of 1, 3 and 5 mCi changed the clarity of the media to turbid, conformed with the performance of positive controls but samples with radioactivity of 10 mCi and 20 mCi did not change the clarity of the media, conformed with the performance of negative control, indicating neither growth of bacteria nor fungi. It is concluded that Tc-99m behaves as an autosterilizing agent at certain radioactivity. Therefore the preparation of Tc-99m radiopharmaceutical can be considered as terminal sterilization rather than aseptic preparation.

  5. Technetium-99m methoxyisobutylisonitrile imaging for parathyroid adenoma: relationship to P-glycoprotein or multidrug resistance-related protein expression

    International Nuclear Information System (INIS)

    Kao, Albert; Shiau, Yu-Chien; Tsai, Shih-Chuan; Wang, Jhi-Joung; Ho, Shung-Tai

    2002-01-01

    Gland size has been reported to have a major influence on localisation of parathyroid adenomas by technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) imaging. It has also been suggested that P-glycoprotein (Pgp) expression in parathyroid adenomas may influence localisation because false negative studies have been reported with large tumours and true positives with very small tumours. Therefore, the purpose of this study was to retrospectively evaluate the relationship between 99m Tc-MIBI parathyroid imaging results and Pgp or multidrug resistance-related protein (MRP) expression in parathyroid adenomas. Before surgery, 47 patients with large parathyroid adenomas (larger than 1.5 g) underwent early and delayed parathyroid imaging, 10 min and 2 h after intravenous injection of 99m Tc-MIBI. Immunohistochemical analyses (IHA) were performed, using multiple non-consecutive sections of the operative specimens, to detect Pgp or MRP expression. According to the results of IHA, the 34 parathyroid adenomas were separated into four groups: (1) three adenomas positive for both Pgp and MRP expression, (2) one adenoma positive for Pgp but negative for MRP expression, (3) four adenomas negative for Pgp but positive for MRP expression and (4) 39 adenomas with negative for both Pgp and MRP expression. All 39 adenomas in group 4 could be detected by 99m Tc-MIBI parathyroid imaging. None of the eight adenomas in groups 1-3 could be detected by 99m Tc-MIBI parathyroid imaging (P 99m Tc-MIBI imaging in localising parathyroid adenomas preoperatively. (orig.)

  6. Technetium-99m HM-PAO-SPECT study of regional cerebral perfusion in early Alzheimer's disease

    International Nuclear Information System (INIS)

    Perani, D.; Di Piero, V.; Vallar, G.

    1988-01-01

    Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPECT) using technetium-99m hexamethylpropyleneamine oxime ([/sup 99m/Tc]HM-PAO) in sixteen patients with Alzheimer's disease (AD) in early clinical phase and in 16 healthy elderly controls. In all patients transmission computed tomography (TCT) and/or magnetic resonance imaging (MRI) did not show focal brain abnormalities. Relative to normal subjects, AD patients showed significant reductions in cortical/cerebellar activity ratio: cortical perfusion was globally depressed with the largest reductions in frontal and posterior temporo-parietal cortices. Asymmetries of relative perfusion between cerebral hemispheres were also demonstrated when language was affected or visuospatial functions were unevenly impaired. In patients with early AD, SPECT provides functional information to be compared with clinical and psychometric data

  7. Autoradiography and density gradient separation of technetium-99m-Exametazime (HMPAO) labelled leucocytes reveals selectivity for eosinophils

    Energy Technology Data Exchange (ETDEWEB)

    Puncher, M.R.B. [Biological Lab., Univ. of Kent, Canterbury (United Kingdom); Blower, P.J. [Nuclear Medicine Dept., Kent and Canterbury Hospital (United Kingdom)

    1994-11-01

    Technetium-99m-Exametazime (HMPAO) is widely used for radiolabelling leucocytes for localization of infection. The subcellular distribution of radionuclide in the labelled cells and the distribution of radioactivity among the leucocyte population are incompletely understood. Frozen section autoradiography was used to determine quantitatively the distribution of {sup 99m}Tc in leucocytes labelled with {sup 99m}Tc-Exametazime. Sections of rapidly frozen suspensions of labelled leucocytes in plasma were autoradiographed on Ilford K2 emulsion and stained with haematoxylin and eosin. Neutrophils, eosinophils and mononuclear cells were separated by Percoll density gradient centrifugation. Cell nuclei were isolated by a rapid cell-breakage and fractionation method. In a typical experiment mean grain densities [grains/100 {mu}m{sup 2} (ESD)] over cells were: eosinophils 31.2 (18.4), neutrophils 3.5 (3.5), mononuclear cells 4.2 (5.1). Mean grain numbers per cell (ESD) were: eosinophils 13 (6.8), neutrophils 1.3 (1.3), mononuclear cells 1.1 (1.3). These findings were confirmed by separation of labelled leucocytes on discontinuous density gradients. In four separation experiments, the mean activity-per-cell ratio for eosinophils to neutrophils was 10.1 (4.8):1, and for eosinophils to mononuclear cells, 14.1 (6.7):1. The subcellular distribution of the label was investigated using image analysis of autoradiographs and cell fractionation. This revealed no selectivity for nuclear or extranuclear compartments. It may be concluded that {sup 99m}Tc-Exametazime has strong selectivity for eosinophils over other leucocytes but no selectivity for nuclear/cytoplasmic compartments. (orig.)

  8. Technetium-99m sestamibi limb scintigraphy in post-traumatic reflex sympathetic dystrophy: preliminary results

    International Nuclear Information System (INIS)

    Sarikaya, A.; Firat, M.F.; Sarikaya, I.; Pekindil, G.; Pekindil, Y.

    2001-01-01

    Reflex sympathetic dystrophy (RSD) has widely variable clinical manifestations. Its pathogenesis remains partially unexplained. RSD is commonly divided into three stages; these stages are not always clearly separable, but staging remains important for correct treatment. Since the disease involves soft tissue alterations as well as bone changes, we decided to investigate whether technetium-99m sestamibi limb imaging can be used to evaluate the soft tissue appearance. Fifteen patients (seven females and eight males; age range 12-68 years) with clinically significant post-fracture RSD were evaluated with both three-phase bone scan (TPBS) and 99m Tc-sestamibi limb scintigraphy. Although, in general, patients with similar duration of disease, clinical stage and TPBS activity tended to have similar patterns of sestamibi uptake, discordant uptake patterns were observed in some patients with clinical stage 1. Thus, of 12 patients with stage I disease, eight had increased 99m Tc-sestamibi activity in the distal part of the affected limb, while three had normal activity and one had decreased activity. All three patients with stage II disease showed normal 99m Tc-sestamibi uptake. Although most of the patients with increased 99m Tc-sestamibi uptake had increased activity on all three phases of the bone scan, there were discordant results between the scan patterns in other patients. On the basis of these findings, we suggest that 99m Tc-sestamibi imaging may contribute to the differentiation between clinical stages and may permit evaluation of the disease course and selection of appropriate therapy. 99m Tc-sestamibi imaging is not, however, a primary diagnostic procedure for RSD. (orig.)

  9. Technetium-99m-ECD SPECT in antiphospholipid antibody syndrome: a drastic improvement in brain perfusion by antiplatelet therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tokumaru, Sunao; Yoshikai, Tomonori; Uchino, Akira; Kudo, Sho [Dept. of Radiology, Saga Medical School (Japan); Matsui, Makoto; Kuroda, Yasuo [Dept. of Neurology, Saga Medical School (Japan)

    2001-12-01

    We present a case of antiphospholipid antibody syndrome (APS) with repeated transient ischemic attacks (TIAs). Magnetic resonance imaging showed multiple cerebral infarcts and ischemic changes in the cerebral white matter. Cerebral angiographies showed no abnormalities. Technetium-99m-ethyl cysteinate dimer (Tc-99m-ECD) brain SPECT showed multiple decreased perfusion areas, which were more extensive than the lesions demonstrated on MRI. After treatment with an antiplatelet agent, the patient subsequently recovered from the TIAs. Although no interval changes were observed by MRI after therapy, follow-up Tc-99m-ECD SPECT revealed a marked improvement in brain perfusion. This is the first imaging report of remarkable post-therapy improvement in brain perfusion in APS cases. (orig.)

  10. Technetium-99m-ECD SPECT in antiphospholipid antibody syndrome: a drastic improvement in brain perfusion by antiplatelet therapy

    International Nuclear Information System (INIS)

    Tokumaru, Sunao; Yoshikai, Tomonori; Uchino, Akira; Kudo, Sho; Matsui, Makoto; Kuroda, Yasuo

    2001-01-01

    We present a case of antiphospholipid antibody syndrome (APS) with repeated transient ischemic attacks (TIAs). Magnetic resonance imaging showed multiple cerebral infarcts and ischemic changes in the cerebral white matter. Cerebral angiographies showed no abnormalities. Technetium-99m-ethyl cysteinate dimer (Tc-99m-ECD) brain SPECT showed multiple decreased perfusion areas, which were more extensive than the lesions demonstrated on MRI. After treatment with an antiplatelet agent, the patient subsequently recovered from the TIAs. Although no interval changes were observed by MRI after therapy, follow-up Tc-99m-ECD SPECT revealed a marked improvement in brain perfusion. This is the first imaging report of remarkable post-therapy improvement in brain perfusion in APS cases. (orig.)

  11. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.; Mishkin, F.S.

    1986-10-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal.

  12. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    International Nuclear Information System (INIS)

    Patel, R.; Mishkin, F.S.

    1986-01-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal

  13. Technetium 99m-labeled annexin v scintigraphy of platelet activation in vegetations of experimental endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D. [Nucl Med Serv, Grp Hosp Bichat Claude Bernard, AP-HP, Paris (France); Rouzet, F.; Sarda-Mantel, L.; LeGuludec, D. [Univ Denis Diderot Paris 7, UMR S773, Paris (France); Rouzet, F.; Sarda-Mantel, L.; Le Guludec, D. [INSERM, U773, Paris (France); Hernandez, M.D.; Louedec, L.; Michel, J.B. [Univ Paris 07, CHU Xavier Bichat, INSERM, U698, Paris (France); Hervatin, F. [CEA, DSV, DRM, SHFJ, Orsay (France); Lefort, A.; Fantin, B. [Univ Denis Diderot Paris 7, EA 3964, Paris (France); Duval, X. [Univ Denis Diderot Paris 7, INSERM, CIC 007, Paris (France); Duval, X. [Univ Denis Diderot Paris 7, AP-HP, Grp Hosp Bichat Claude Bernard, Ctr Invest Clin, Paris (France); Hernandez, M.D. [Univ Guadalajara, DeptPathol, Guadalajara 44430, Jalisco (Mexico)

    2008-07-01

    Background: The pathophysiology of infective endocarditis involves a pathogen/host tissue interaction, leading to formation of infected thrombotic vegetations. Annexin V is a ligand of phosphatidyl-serines exposed by activated platelets and apoptotic cells. Because vegetations are platelet-fibrin clots in which platelet pro-aggregant activity is enhanced by bacterial colonization, we investigated the ability of annexin V labeled with technetium {sup 99m}Tc ({sup 99m}Tc-ANX) to provide functional imaging of these vegetations in experimental models of infective endocarditis. This ability was assessed in rabbits and rats because of the different interest of these 2 species in preclinical analysis. Methods and Results: Non-bacterial thrombotic endocarditis was induced with the use of a catheter left indwelling through the aortic or tricuspid valve, and animals were injected with either a bacterial inoculum or saline. Scintigraphic investigations were performed 5 days later and showed a higher {sup 99m}Tc-ANX uptake by vegetations in infected versus non-infected animals (ratio,1.3 for in vivo acquisitions and 2 for autoradiography; P {<=} 0.0001 for all), whereas no significant uptake was present in controls. Right-sided endocarditis was associated with pulmonary uptake foci corresponding to emboli. Histological analysis of vegetations showed a specific uptake of {sup 99m}Tc-ANX at the interface between circulating blood and vegetation. In parallel, underlying myocardial tissue showed myocyte apoptosis and mucoid degeneration, without extracellular matrix degradation at this stage. Conclusions: {sup 99m}Tc-ANX is suitable for functional imaging of platelet-fibrin vegetations in endocarditis, as well as embolic events. {sup 99m}Tc-ANX uptake reflects mainly platelet activation in the luminal layer of vegetations. This uptake is enhanced by bacterial colonization. (authors)

  14. Status of Tc-99m and 99Mo/99mTc generator production in Bangladesh

    International Nuclear Information System (INIS)

    Abedin, Md. Zainul; Haque, Md. Azizul; Ali, Md. Ramjan; Hossain, Md. Anwar; Razzaque, Md. Abdur; Yasmin, Lyzu; Waheed, M. Fatima; Akhter, Rabeya; Mondal, Rafiuddin

    2007-01-01

    Radioisotope Production Division (RIPD) produced instant technetium-99m by solvent extraction method for several years. On R and D basis, the division produced portable sterile Tc-99m sublimation generator by irradiating titanium molybdate in the reactor. The division produced (4/batch) from imported fission Mo-99 till June 2005. Since August 2005, as per demand of the government hospitals, the division have been producing 12-14 pieces of 15 GBq chromatographic 99m Tc-generators weekly by using the new generator production plant installed last year having online Mo-99 loading system with the of producing 50 generator per batch. Development of PZC and (n,γ) 99 Mo based generator holds potential in Bangladesh. (author)

  15. The role of Technetium99m-MIBI in the follow-up of differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Machado, L.S.; Corbo, R.; Pedras, D.S.V.; Anttonuccia, J.B.

    2004-01-01

    Full text: Technetium-99m-methoxyisobutylisonitrile (99mTc-MIBI) is being used as a tumor-seeking agent over the last few years. We evaluated the role of 99mTc-MIBI whole body scan (WBS) in localizing metastatic lesions in patients with thyroid cancer and compared the results with 131I scan and serum thyroglobulin (Tg) levels. Eighty nine patients of differentiated thyroid cancer subjected to thyroidectomy were enrolled for the study. Early (20 minutes) and delayed (6 and 24 hours) whole body images were obtained after injecting 99mTc-MIBI. Tg measurements were obtained during thyroid hormone replacement and 4 weeks after hormone discontinuation. 131I scans were performed after low diagnostic or high ablative/therapeutic dose. These methods were used as standard to evaluate the presence of residual or metastatic thyroid cancer. The patients with positive 99mTc-MIBI scan but negative 131I scan underwent chest x-ray, computed tomography (CT) or magnetic resonance imaging (MRI). 34 of the total 89 patients were found to be negative on 131I scan. 23 of these 34 patients had negative 99mTc-MIBI WBS and 11 patients were positive for abnormal MIBI uptake (specificity: 67.6%). Twenty-two patients had both 99mTc-MIBI WBS and 131I scan positive. Eleven patients had 131I scan negative and 99mTc-MIBI WBS positive; seven of those proved to be true positive. From the findings of our study, it may be concluded that although 99mTc-MIBI has low sensitivity for detection of tumor recurrence, it definitely has a role as a supplementary tool to thyroglobulin measurements and 131I scans. (author)

  16. Effects of fenoprofen on the labeling of blood constituents with technetium-99m, the morphology of red blood cells and the plasmid

    International Nuclear Information System (INIS)

    Pereira, Marcia de Oliveira; Rocha, Gabrielle de Souza; Lombardi, Simone dos Santos; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario; Pereira, Mario Jose; Geller, Mauro

    2008-01-01

    The aim of this work was to evaluate the effect of fenoprofen on the labeling of blood constituents with technetium- 99m, on the morphology of red blood cells and on the plasmid DNA. Blood samples from Wistar rats were incubated with fenoprofen and the assay of labeling of blood constituents with technetium-99m ( 99m Tc) was performed. Blood cells, plasma, soluble and insoluble fractions of blood cells and plasma were separated. The radioactivity in each fraction was counted and percentage of incorporated radioactivity (%ATI) was determined. Blood smears were prepared, fixed, stained and the qualitative and quantitative morphology of the red blood cells (RBC) was evaluated. Plasmid (pBSK) was incubated with fenoprofen with stannous chloride, and agarose gel electrophoresis procedure was carried out to evaluate genotoxic and the protection of this drug against stannous chloride effect on DNA. In conclusion, under the conditions used in this work, our data suggest that fenoprofen would not affect the fixation of the 99m Tc on the blood constituents, alter the RBC membrane and present genotoxic and redox effects. (author)

  17. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    Science.gov (United States)

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  18. Non-invasive investigation of the upper gastrointestinal tract using technetium - 99m

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, T V [Royal Infirmary, Edinburgh (UK)

    1979-01-01

    The use of technetium - 99m in the non-invasive investigation of the upper gastrointestinal tract is discussed with particular reference to the evolution of a method of assessing gastric function or gastric acid secretion non-invasively and to the applications of this method in the investigation of surgical patients with disease of the upper gastrointestinal tract. The assessment of maximal acid output and the insulin response is described and the use of the test in the diagnosis of pernicious anaemia, hypo- and hyperchlorhydric states, gastric cancer, hiatus hernia and Barrett's oesophagus, coeliac disease, Meckel's diverticulum, and abdominal aortic aneurism outlined. The use of chemicals labelled with this tracer in hepatobilary scanning is briefly described.

  19. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  20. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  1. Tumor scintigraphy by the method for subtracting the initial image with technetium-99m labeled antibody

    International Nuclear Information System (INIS)

    Karube, Yoshiharu; Katsuno, Kentaro; Ito, Sanae; Matsunaga, Kazuhisa; Takata, Jiro; Kuroki, Masahide; Murakami, Masaaki; Matsuoka, Yuji

    1999-01-01

    The method for subtracting the initial image from the localization image was evaluated for radioimmunoscintigraphy of tumors with technetium-99m (Tc-99m) labeled antibodies. Monoclonal antibodies were parental mouse and mouse-human chimeric antibodies to carcinoembryonic antigen (CEA), designated F11-39 and ChF11-39, respectively, both of which have been found to discriminate CEA in tumor tissues from the CEA-related antigens. After reduction of the intrinsic disulfide bonds, these antibodies were labeled with Tc-99m. In vivo studies were performed on athymic nude mice bearing the human CEA-producing gastric carcinoma xenografts. Though biodistribution results showed selective and progressive accumulation of Tc-99m labeled antibodies at the tumor site, high radioactivity in blood was inappropriate for scintigraphic visualization of the tumors within a few hours. We examined the subtraction of the initial Tc-99m image from the Tc-99m localization image after a few hours. Subtracted images of the same count reflected the in vivo behavior of the Tc-99m radioactivity. The subtracted scintigrams revealed excellent tumor images with no significant extrarenal background. Visualization of the tumor site was dependent on antigen-specific binding and nonspecific exudation. These results demonstrate that a method of subtraction of the initial image may serve as a potentially useful diagnostic method for an abnormal site for agents with a low pharmacokinetic value. (author)

  2. Mercaptoacetyltriglycine-3 renogram is not superior to estimated glomerular filtration rate measurement for the prediction of long-term renal function after nephrectomy

    International Nuclear Information System (INIS)

    Kanamaru, Hiroshi; Yamamoto, Masakazu; Nagahama, Kanji

    2011-01-01

    The objective of this study was to evaluate the clinical usefulness of effective renal plasma flow (ERPF) measured using preoperative mercaptoacetyltriglycine-3 (MAG3) renogram for the prediction of chronic renal insufficiency after nephrectomy. A total of 47 patients underwent preoperative MAG3 renal scintigraphy and subsequent unilateral nephrectomy. Correlations between the 5-year postoperative estimated glomerular filtration rate (eGFR) and the preoperative ERPF of the contralateral kidney (cERPF), ERPF of the diseased kidney (dERPF), total ERPF (tERPF), cERPF to dERPF ratio, serum creatinine (sCr) level, eGFR, as well as the influence of preoperative comorbidities (diabetes, hypertension) on the postoperative eGFR, were evaluated with both univariate and multivariate analyses. Multiple linear regression analysis showed that preoperative cERPF significantly correlated with postoperative eGFR. However, a much stronger correlation was observed between the preoperative and postoperative eGFR. Multiple logistic regression analysis showed that only preoperative eGFR was a significant predicator of the development of advanced-stage chronic kidney disease (CKD). Preoperative MAG3 renogram is not superior to eGFR measurement as a prognostic indicator of long-term renal function after unilateral nephrectomy. (author)

  3. Technetium-99m methoxyisobutylisonitrile imaging for parathyroid adenoma: relationship to P-glycoprotein or multidrug resistance-related protein expression

    Energy Technology Data Exchange (ETDEWEB)

    Kao, Albert [Departments of Nuclear Medicine and Medical Research, China Medical College Hospital, No. 2, Yuh-Der Road, Taichung 404 (Taiwan); Shiau, Yu-Chien [Department of Nuclear Medicine, Far Eastern Memorial Hospital, Institute of Biomedical Engineering, College of Electrical Engineering, National Taiwan University, Taipei (Taiwan); Tsai, Shih-Chuan [Department of Nuclear Medicine, Show-Chwan Memorial Hospital, Chunghua (Taiwan); Wang, Jhi-Joung [Department of Medical Research, Chi-Mei Medical Center, Tainan (Taiwan); Ho, Shung-Tai [School of Medicine, National Defense Medical Center, Taipe (Taiwan)

    2002-08-01

    Gland size has been reported to have a major influence on localisation of parathyroid adenomas by technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) imaging. It has also been suggested that P-glycoprotein (Pgp) expression in parathyroid adenomas may influence localisation because false negative studies have been reported with large tumours and true positives with very small tumours. Therefore, the purpose of this study was to retrospectively evaluate the relationship between {sup 99m}Tc-MIBI parathyroid imaging results and Pgp or multidrug resistance-related protein (MRP) expression in parathyroid adenomas. Before surgery, 47 patients with large parathyroid adenomas (larger than 1.5 g) underwent early and delayed parathyroid imaging, 10 min and 2 h after intravenous injection of {sup 99m}Tc-MIBI. Immunohistochemical analyses (IHA) were performed, using multiple non-consecutive sections of the operative specimens, to detect Pgp or MRP expression. According to the results of IHA, the 34 parathyroid adenomas were separated into four groups: (1) three adenomas positive for both Pgp and MRP expression, (2) one adenoma positive for Pgp but negative for MRP expression, (3) four adenomas negative for Pgp but positive for MRP expression and (4) 39 adenomas with negative for both Pgp and MRP expression. All 39 adenomas in group 4 could be detected by {sup 99m}Tc-MIBI parathyroid imaging. None of the eight adenomas in groups 1-3 could be detected by {sup 99m}Tc-MIBI parathyroid imaging (P<0.05). It is concluded that not only the size of parathyroid adenomas but also significant Pgp or MRP expression limits the sensitivity of {sup 99m}Tc-MIBI imaging in localising parathyroid adenomas preoperatively. (orig.)

  4. 99mTechnetium labelled Escherichia coli

    International Nuclear Information System (INIS)

    Diniz, S.O.F.; Cardoso, V.N.; Resende, B.M.; Nunan, E.A.; Simal, C.J.R.

    1999-01-01

    Samples of a culture of unlabeled Escherichia coli were incubated with different concentrations of stannous chloride for various time periods. 99m Tc (26.0 MBq) was added to each preparation and the results showed a labelling yield of 98% for E. coli. Since the bacterial viability of 99m Tc-E. coli and E. coli did not show any statistical differences, these results demonstrate that labelling of E. coli with 99m Tc does not modify the bacterial viability, and the radiolabelled bacteria may be a good model to study bacterial translocation

  5. On-site preparation of technetium-99m labeled human serum albumin for clinical application

    International Nuclear Information System (INIS)

    Wang Yuhfeng; Chuang Meihua; Cham Thauming; Chung Meiing; Chiu Jainnshiun

    2007-01-01

    Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessment. However, because of transfusion-induced infectious diseases, the safety of serum products is a serious concern. In this context, serum products acquired from patients themselves are the most ideal tracer. However, the development of rapid separation and easy clinical labeling methods is not yet well established. Under such situation, products from the same ethnic group or country are now recommended by the World Health Organization as an alternative preparation. This article describes the on-site preparation of Tc-99m HSA from locally supplied serum products. Different formulations were prepared and the labeling efficiency and stability were examined. Radio-labeling efficiencies were more than 90% in all preparation protocols, except for one that omitted the stannous solution. The most cost-effective protocol contained HSA 0.1 mg, treated with stannous fluoride 0.2 mg, and mixed with Tc-99m pertechnetate 30 mCi. A biodistribution study was performed in rats using a gamma camera immediately after intravenous administration of radiolabeled HSA. Tissue/organ uptake was obtained by measuring the radioactivity in organs after sacrificing the rats at timed intervals. The biologic half-life was about 32 min, determined from sequential venous blood collections. These data indicate that our preparation of Tc-99m HSA is useful and potentially applicable clinically. In addition, this on-site preparation provides the possibility of labeling a patient's own serum for subsequent clinical application. (author)

  6. Contribution to optimization of individual doses of workers in shipment of generator technetium-99m

    International Nuclear Information System (INIS)

    Fonseca, Lizandra Pereira de Souza

    2010-01-01

    The Instituto de Pesquisas Energeticas e Nucleares, IPEN, radiopharmaceuticals research and produce that are distributed throughout Brazil, currently the radiopharmaceutical with the largest number of packaged shipped per year and with the highest total activity is the 99m technetium generator. To reduce individual doses for workers involved in the production of radiopharmaceuticals was performed a study of radiological protection optimization in the shipment process of technetium generator, using the techniques: differential cost-benefit analysis, integral cost-benefit analysis, multi-attribute utility analysis and multi-criteria outranking analysis. With changes in the configuration of packed for generator dispatch and with the acquirement of a mat transporter it was possible establish 4 protection options. The attributes considered were the protection cost, collective dose, individual dose and physical effort by worker to move the package without the mat. To assess the robustness of analytical solutions found with the techniques used in the optimization we performed a sensitivity study and found that option 3 is more robust than option 1, which is no longer the analytical solution with an increase of R$ 20.000,00 the cost of protection. (author)

  7. Use of new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.

    1998-01-01

    In this paper we describe the first application of our simple and inexpensive post-elution tandem cation/anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical-scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine-type (QMA SepPak TM ) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator. (author)

  8. Kit for preparing a technetium-99m myocardial imaging agent

    International Nuclear Information System (INIS)

    Woulfe, S.R.; Deutsch, E.A.; Dyszlewski, M.; Neumann, W.L.

    1992-01-01

    This patent describes a kit for preparing a technetium 99m myocardial imaging agent. It comprises a first vial containing a lyophilized pyrogen free, sterile mixture of an effective reducing agent and a first ligand having the following general formula: wherein the R 1 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde and nitrile; the R 2 groups may be the same or different and are selected from the group consisting of hydrogen, hydroxy, C 1 - C 5 alkyl, C 1 - C 5 alkyl substituted by hydroxyl, ether, ester, amide, ketone, aldehyde, and nitrile; the X and Y groups may be the same or different and are selected from the group consisting of oxygen and sulfur; and n is equal to 1 or 2; and a second vial containing a lyophilized pyrogen free, sterile protected salt of a phosphine ligand

  9. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    International Nuclear Information System (INIS)

    Buckland-Wright, J.C.; Lynch, J.A.; Macfarlane, D.G.; Homoeopathic Hospital, Tunbridge; Fogelman, I.; Emery, P.

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.)

  10. Technetium 99m methylene diphosphonate bone scanning in osteoarthritic hands

    Energy Technology Data Exchange (ETDEWEB)

    Buckland-Wright, J.C.; Lynch, J.A. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy); Macfarlane, D.G. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Anatomy Homoeopathic Hospital, Tunbridge (UK). Dept. of Rheumatology); Fogelman, I. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Nuclear Medicine); Emery, P. (United Medical and Dental Schools of Guy' s and Saint Thomas' , London (UK). Dept. of Rheumatology)

    1991-01-01

    In this prospective study, the radiological features characteristic of osteoarthritis of the hand were compared with the radionuclide bone scan images. A total of 32 patients was assessed at 6-monthly intervals for 18 months. Microfocal radiographs were taken at each visit. The high magnification and resolution of this technique permitted direct measurement of joint space width, subchondral sclerosis, osteophyte number and area and juxta-articular radiolucency area for each joint in the hand. Four-hour technetium 99m methylene diphosphonate bone scans were taken at 0 and 12 months and the activity of tracer uptake at each joint scored. The latter was compared with each X-radiographic feature at every visit and the changes between visits analysed. The scan scores did not correlate with any of the X-radiographic features other than osteophyte size. During the study the size of growing and remodelling osteophytes increased significantly at joints with raised or increased isotope uptake. (orig.).

  11. Scintigraphic imaging with technetium-99M-labelled ceftizoxime is a reliable technique for the diagnosis of deep sternal wound infection in rats

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Paulo Henrique Nogueira; Diniz, Simone Odilia Fernandes; Cardoso, Valbert Nascimento; Tarabal, Bernardo; Takenaka, Isabella; Braga, Otavio; Vidigal, Paula Vieira Teixeira; Gelape, Claudio Leo; Araujo, Ivana Duval, E-mail: phnc@uol.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2015-07-01

    Purpose: to evaluate whether scintigraphy with technetium-99m-labeled ceftizoxime ({sup 99m}Tc-CFT) can differentiate mediastinitis from aseptic inflammation associated with sternotomy. Methods: twenty female Wistar rats were randomly distributed into four groups: S (control) -partial upper median sternotomy with no treatment; SW (control) - sternotomy and treatment of sternal wounds with bone wax; SB - sternotomy and infection with Staphylococcus aureus; SWB - sternotomy with bone wax treatment and bacterial infection. Scintigraphy with {sup 99m}Tc-CFT was performed eight days after surgery and images were collected 210 and 360 min after infusion of the radiopharmaceutical. Results: no animals exhibited clinical signs of wound infection at the end of the experiment, although histological data verified acute inflammatory response in those experimentally infected with bacteria. Scintigraphic images revealed that tropism of {sup 99m}Tc-CFT to infected sternums was greater than to their non-infected counterparts. Mean counts of radioactivity in bacteria-infected sternal regions (SB and SWB) were significantly higher (p = 0.0007) than those of the respective controls (S and SW).Conclusion: scintigraphy with technetium-99m-labeled ceftizoxime is a method that can potentially detect infection post sternotomy and differentiate from aseptic inflammation in animals experimentally inoculated with S. aureus (author)

  12. Is Technetium-99m Sestamibi Imaging Able to Predict Pathologic Nonresponse to Neoadjuvant Chemotherapy in Breast Cancer? : A Meta-analysis Evaluating Current Use and Shortcomings

    NARCIS (Netherlands)

    Collarino, Angela; de Koster, Elizabeth J.; Valdés Olmos, Renato A.; de Geus-Oei, Lioe Fee; Pereira Arias-Bouda, Lenka M.

    2017-01-01

    Background: Interest in technetium-99m (99mTc)-sestamibi imaging for neoadjuvant chemotherapy (NAC) response monitoring in locally advanced breast cancer (LABC) is increasing but remains matter of discussion. The present study conducted a meta-analysis of the diagnostic performance of

  13. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    Science.gov (United States)

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  14. Neutral and stereospecific Tc-99m complexes: [99mTc]N-benzyl-3,4-di-(N-2-mercaptoethyl)-amino-pyrrolidines (P-BAT)

    International Nuclear Information System (INIS)

    Zhuang Zhiping; Ploessl, Karl; Kung Meiping; Mu Mu; Kung, Hank F.

    1999-01-01

    Technetium-99m-labeled radiopharmaceuticals are currently the most commonly used agents in nuclear medicine. To prepare binding site-specific small molecules containing a Tc-99m complexing core, it is important to consider a ligand system, which selectively forms only one stereoisomer. A novel series of bisaminoethanethiol (BAT) derivatives as a model system were prepared. Stereoisomers of N-benzyl-3,4-di-(N-2-mercaptoethyl)-amino pyrrolidines (P-BAT): (3R,4R)-P-BAT (R,R-4) and (3,4)meso-P-BAT (8), the trans and meso isomer, respectively, as a chelating group were prepared successfully. The desired Tc-99m P-BAT complexes were obtained by using Sn(II)/glucoheptonate as the reducing agent for [ 99m Tc]pertechnetate. As predicted, after complexation with [ 99m Tc]Tc v O, the trans isomer, (3R,4R)-P-BAT (R,R-4), showed only one isomer; whereas the corresponding meso isomer, (3,4)meso-P-BAT (8), produced two distinctive complexes isolated readily by high performance liquid chromatography (HPLC). The [ 99m Tc](R,S)meso-P-BAT (8) isomers showed a different lipophilicity (partition coefficient [P.C.]=54.3 and 55.4 for peak A and peak B, respectively), as compared with that of the corresponding [ 99m Tc](3R,4R)-P-BAT (R,R-4), trans isomer ( P.C.=163). Results of the biodistribution study in rats of these isomers show different heart and brain uptake, suggesting that the intrinsic differences in biodistribution are due to structural and stereospecific factors. Examples in this report confirm that it is possible to design stereospecific Tc-99m complexes based on the bisaminoethanethiol (N 2 S 2 , BAT) ligand system. Consideration on stereoselectivity of site-specific agents labeled with Tc-99m is likely an essential requirement on developing binding-site specific radiopharmaceuticals

  15. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m; Estudo comparativo entre metodologias de cromatografia planar para controle radioquimico de radiofarmacos de tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Elisiane de Godoy

    2012-07-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ({sup 99}mTc), obtained from {sup 99}Mo/{sup 99}mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in {sup 99m}Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ({sup 99}mTcO{sub 4}{sup -}) and technetium colloidal (99mTcO{sub 2}) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with {sup 99m}Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. {sup 99m}TcO{sub 4}{sup -} eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL{sup 1} (1,5 mCi mL{sup 1}) of final radioactive concentration. The %{sup 99m}TcO{sub 4}{sup -}, %{sup 99m}TcO{sub 2} and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was

  16. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  17. Comparison of technetium-99m methoxyisobutylisonitrile and gallium-67 citrate scanning in the assessment of lymphomas

    International Nuclear Information System (INIS)

    Ziegels, P.; Nocaudie, M.; Huglo, D.; Deveaux, M.; Detourmignies, L.; Wattel, E.; Marchandise, X.

    1995-01-01

    The aim of this study was to compare the value of scintigraphy using technetium-99m methoxy-isobutylisonitrile (MIBI) with that of scintigraphy using gallium-67 citrate in the assessment of Hodgkin's disease and non-Hodgkin's lymphoma and to relate these results with those of CT scan and MRI. Fifty-eight patients were included either for a follow-up examination or for monitoring of their treatment. Twenty-three residual masses were studied. A whole-body scan was performed, followed by single-photon emission computed tomography (SPET) 20 min after injection of 740 MBq of 99m Tc-MIBI and 72 h after injection of 185 MBq of 67 Ga citrate. The overall sensitivity of 99m Tc-MIBI and 67 Ga citrate was 71% and 68%, respectively, and the overall specificity was 76% and 44%, respectively. For residual masses, the sensitivity was 44% with both tracers and the specificity was 80% with 99m Tc-MIBI and 53% with 67 Ga citrate. The positive predictive values were 85% and 68% and the negative predictive values were 59% and 44%, respectively. The signal-to-background ratio was 1.5 for 99m Tc-MIBI and 2 for 67 Ga citrate. At present, 99m Tc-MIBI cannot replace 67 Ga citrate in the assessment of lymphomas. (orig.)

  18. Radiolabeling of gemifloxacin with technetium-99m and biological evaluation in artificially Streptococcus pneumoniae infected rats

    International Nuclear Information System (INIS)

    Syed Qaiser Shah; Muhammad Rafiullah Khan

    2011-01-01

    In the current investigation complexation of the gemifloxacin (GIN) with technetium-99 m ( 99m Tc) and its biological evaluation in artificially Streptococcus pneumoniae (S. pneumoniae) infected rats was assessed as potential S. pneumoniae infection radiotracer. Radiochemically the 99m Tc-GIN complex was further analyzed in terms of stability in saline, in vitro stability in serum at 37 deg C, in vitro binding with S. pneumoniae and biodistribution in artificially S. pneumoniae (living and heat killed) infected rats. The complex was found 97.25 ± 0.25% radiochemically stable in saline at 30 min after reconstitution. The stability of the 99m Tc-GIN complex was decreased to 90.50 ± 0.20% within 240 min after reconstitution. In serum the 99m Tc-GIN complex showed stable profile with the appearance of 18.85% free tracer within 16 h of incubation. The 99m Tc-GIN complex showed saturated in vitro binding with S. pneumoniae after different intervals. Almost five fold uptake was observed in living S. pneumoniae infected muscle of the rats as compared to the inflamed and normal muscle. No significant difference in the uptake of heat killed S. pneumoniae infected, inflamed and normal muscles of the rats. The high RCP yield in saline, in vitro permanence in serum, in vitro binding with living S. pneumoniae and biodistribution in artificially S. pneumoniae infected rats we recommend the 99m Tc-GIN as potential S. pneumoniae infection radiotracer. (author)

  19. Clinical studies of alveolar-capillary permeability using technetium-99m DTPA aerosol

    International Nuclear Information System (INIS)

    Sundram, F.X.

    1995-01-01

    Soluble radioaerosols such as technetium-99m diethylene triamine pentacetate (DTPA) permit simple quantitative studies of alveolar-capillary permeability to be performed, since the submicronic aerosols are deposited mainly at the lung periphery and are cleared across the alveolar-capillary membrane. Regional alterations in permeability can also be noted using this radionuclide technique. We have measured the pulmonary epithelial permeability in normal subjects and the alteration in smokers, glue-sniffers, patients with inhalation burns, chronic obstructive pulmonary disease (COPD) and patients with lung metastases from thyroid cancer treated with radioiodine 131 I. In the normal volunteers, the time taken for 50% of inhaled 99m Tc DTPA to be cleared from the lungs (T1/2) was 66 minutes±1 sd of 12 mins. The smokers had a mean T1/2 of 20 mins±1 sd 4 min. In the hard-core glue-sniffing group, the majority were smokers who had stopped smoking and glue-sniffing for periods varying from 1 day to 42 days, and it was possible to note the changes in clearance times against period of abstinence. In the patients with inhalation burns, there was change in lung clearance arising from pulmonary epithelial damage; these patients showed increased rate of clearance (short T1/2) with mean T1/2 of 36 min±1 sd of 11 mins, while the retention images revealed regional lung damage in moderately severe inhalation burns. Twenty-four patients with COPD had inhalation scans done with Tc-99m tin colloid radioaerosol, and these images were compared with the perfusion lung scans done with 99m Tc macroaggregated albumin (MAA); in general the perfusion images matched the defects noted in the inhalation scans. The 99m Tc DTPA clearance rate in these patients was normal i.e. T1/2=78±14 mins. In the thyroid cancer patients with lung metastases, who had high doses of radioiodine treatment, the T1/2 values were normal or prolonged slightly, mean T1/2=76 min±23. (author)

  20. Use of technetium-99m-di-isopropyl-iminodiacetic acid imaging in the demonstration of a biliary-bronchial fistula

    Energy Technology Data Exchange (ETDEWEB)

    Savitch, I.; Esser, J.D.; Levin, J. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Nuclear Medicine); Krige, L.P.; Kew, M.C. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Medicine)

    1984-05-12

    A case is described in which technetium-99m-di-isopropyl-iminodiacetic acid imaging was used to trace the passage of bile from its site of leakage into an amoebic liver abscess, through a fistulous tract connecting the liver abscess with an abscess in the right lower lobe of the lung, and into the upper respiratory tract.

  1. Reference Ranges in [(99m)Tc]Mercaptoacetyltriglycerine Renography

    DEFF Research Database (Denmark)

    Rewers, Kate I; Hvidsten, Svend; Gerke, Oke

    2015-01-01

    PURPOSE: The purpose of the study was to define reference ranges for quantitative parameters in [(99m)Tc]mercaptoacetyltriglycerine ([(99m)Tc]MAG3) renography to assist interpretation in a semi-automated (Xeleris, GE) compared to a manual (Picker, Odyssey) software package. PROCEDURES: Forty......-eight subjects approved for renal donation were evaluated with [(99m)Tc]MAG3 renography using both the Xeleris and the Picker software. RESULTS: Reference ranges for the two software were comparable regarding the relative function of the two kidneys (the split function, SF) and the residual activities (RA......). The time to peak whole-kidney activities (T max whole-kidney) was more dependent on the type of software. Using Bland-Altman limits, we found good and acceptable agreement between the two methods. CONCLUSIONS: We found good correlation between renography results using the Xeleris and Picker software...

  2. Scintimammography with technetium-99m methoxyisobutylisonitrile: results of a prospective European multicentre trial

    Energy Technology Data Exchange (ETDEWEB)

    Palmedo, H.; Biersack, H.J. [Bonn Univ. (Germany). Dept. of Nucl. Med.; Lastoria, S. [Department of Nuclear Medicine, National Cancer Institute of Naples (Italy); Maublant, J. [Department of Nuclear Medicine, Centre Jean Perrin in Clermont Ferrand (France); Prats, E. [Department of Nuclear Medicine, University Hospital of Zaragoza (Spain); Stegner, H.E. [Department of Gynecology, University of Hamburg (Germany); Bourgeois, P. [Department of Nuclear Medicine, Hospital St. Pierre in Bruxelles (Belgium); Hustinx, R. [Department of Nuclear Medicine, University Hospital in Liege (Belgium); Hilson, A.J.W. [Department of Nuclear Medicine, NHS Trust Hospital in London (United Kingdom); Bischof-Delaloye, A. [Department of Nuclear Medicine, University of Lausanne (Switzerland)

    1998-04-01

    The aim of the trial was to determine the diagnostic accuracy of scintimmammography with technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) in the detection of primary breast cancer and to verify its clinical usefulness. A total of 246 patients with a suspicious breast mass or positive mammogram were included in this prospective European multicentre trial. At 5 min and 60 min (optional) p.i. two lateral prone images were acquired for 10 min each; 30 min p.i. one anterior image was acquired for 10 min. There were 253 lesions (195 palpable and 58 non-palpable), in respect of which histology revealed 165 cancers and 88 benign lesions. Institutional and blinded read results were correlated to core laboratory histopathology results obtained during excisional biopsy. Diagnostic accuracy for the detection of breast cancer was calculated per lesion. The overall sensitivity and specificity of blinded read scintimammography were 71% and 69%, respectively. For palpable lesions, the sensitivity of blinded read and institutional read scintimammography was 83% and 91%, respectively. Sensitivity was not dependent on the density of the breast tissue. Invasive ductal and invasive lobular cancers showed similar sensitivity. The sensitivity and specificity of mammography were 91% and 42%, respectively, and did not depend on the tumour size. In 60% of false-negative mammograms, {sup 99m}Tc-MIBI was able to diagnose malignancy (true-positive). High-quality imaging with {sup 99m}Tc-MIBI has a high diagnostic accuracy for the detection of primary breast cancer. Used as a complementary method, scintimammography with {sup 99m}Tc-MIBI can help to diagnose breast cancer at an earlier stage in patients with dense breasts. (orig.) With 6 figs., 12 tabs., 55 refs.

  3. Scintigraphic evaluation of chronic cholecystitis with cholelithiasis using technetium-99m-labelled pyridoxylidene isoleucine

    International Nuclear Information System (INIS)

    Alp, E.; Bekdik, C.F.; Laleli, Y.; Ercan, M.T.

    1981-01-01

    Technetium-99m-labelled pyridoxylidene isoleucine was evaluated in normal subjects as a hepatobiliar scanning agent and in patients with chronic cholecystitis with cholelithiasis. In all the normals and patients the liver function tests (SGOT, SGPT, AP and serum bilirubin) were normal. Scintigraphic studies were performed at 5, 10, 15, 20, 25, 30 and 60 min after IV administration of the agent. In the normal group (seven subjects) liver was visualized at 5 min, the common bile duct and the gall bladder at 5-15 min and the bowel activity within 20 min. In the patient group (15 subjects) the liver and the common bile duct were visualized at the same time as in the normal group but the gall bladder was either visualized later or not at all. The results showed that chronic cholecystitis with cholelithiasis may be diagnosed with 87% accuracy using 99 Tcsup(m)-pyridoxylidene isoleucine cholescintigraphy. Scintigraphy with this agent has also superiority over roentgenologic examination in 20% of the cases. (author)

  4. Imaging of intraperitoneal tumors with technetium-99m GSA

    International Nuclear Information System (INIS)

    Yao, Zhengsheng; Zhang, Meili; Sakahara, Harumi; Saga, Tsuneo; Nakamoto, Yuji; Sato, Noriko; Zhao, Songji; Konishi, Junji; Arano, Yasushi

    1998-01-01

    99m Tc labeled galactosyl serum albumin (GSA) has been used clinically as a receptor-binding agent for the assessment of liver function. The aim of this study was to investigate the usefulness of 99m Tc-GSA in intraperitoneal (i.p.) tumor imaging. A tumor model was established by i.p. inoculating nude mice with human ovarian cancer cell SHIN-3, or colon cancer cell LS180. Radiolabels were i.p. injected into the tumor-bearing mice and the biodistribution of radioactivity was examined. After administration, 99m Tc-GSA rapidly accumulated in the tumor. The tumor uptake was 5.82-8.46% ID/g from 30 min to 6 h after the injection. Radioactivity in the blood was very low, less than 0.3% ID/g, resulting in high tumor-to-blood ratio. Tumors could be clearly seen by scintigraphic imaging. Accumulation of i.p.-injected 99m Tc labeled human serum albumin (HSA) in i.p. tumors was similar to that of 99m Tc-GSA, but radioactivity of 99m Tc-HSA in the circulation was high, resulting in a significantly lower tumor-to-blood ratio. In conclusion, 99m Tc-GSA, when i.p. injected, accumulated in i.p. tumors and cleared from circulation rapidly, which would make it useful for the imaging of i.p. tumors. (author)

  5. Pharmaceutical grade sodium (99mTc) pertechnetate from 99Mo/99mTc-TCM-Autosolex generator

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha

    2014-01-01

    Technetium-99m (T 1/2 = 6.02h; 140.51 keV (89%)) is the most useful radioisotope in diagnostic nuclear medicine. More than 80% of all diagnostic procedures done worldwide in nuclear medicine centre are performed with 99m Tc. Worldwide crisis of fission 99 Mo based generator in recent past had put the nuclear medicine fraternity in very harsh situation. In order to have an indigenous solution of this problem, we tried to develop a computer controlled semi automated 99 Mo/ 99m Tc generator using MEK solvent extraction technique, which utilizes abundantly available 99 Mo produced by (n,γ) reaction in BARC reactors. The aim of this work is to provide a more reliable, computer controlled module (TCM- AUTOSOLEX) for the recovery of pharmaceutical grade 99m Tc from low specific activity 99 Mo based on solvent extraction methodology

  6. Kinetics of hypodermically injected technetium-99m and correlation with cutaneous structures: an experimental study in dogs

    International Nuclear Information System (INIS)

    Kovacs, F.M.; Gotzens, V.; Garcia, A.; Garcia, F.; Mufraggi, N.; Prandi, D.; Setoain, J.; San Roman, F.

    1993-01-01

    We investigated the involvement of cutaneous structures in specific linear migration pathways of technetium-99 m pertechnetate hypodermically injected at points of low electrical resistance in the metacarpus of male beagles. Skin-deep incisions were made in the front or back legs on either the same side as the 99m Tc injection or on the opposite side. Incisions in the back legs did not affect the migration pattern. Incisions in the front legs before the injection of 99m Tc prevented tracer migration. After the injection of 99m Tc, incisions in the front contralateral leg caused sudden cessation of the migration, while incisions in the ipsilateral leg caused immediate disappearance of the pathway previously observed. Radioactivity was not detected in flaps obtained from the skin overlying the migration pathway or from the corresponding area of the contralateral leg. In conclusion, the specific linear migration pathways of 99m Tc hypodermically injected at points of low electrical resistance cannot be explained by any known biological function. Although the migration of 99m Tc does not seem to be strongly linked to any cutaneous structure, the skin overlying the radioactive pathway and the corresponding area of the contralateral leg must be intact if tracer migration is to take place. (orig.)

  7. Assessment of the effect of phytic acid on the labeling of blood cells and plasma proteins with Technetium-99m

    International Nuclear Information System (INIS)

    Lima-Filho, Guilherme L.; Freitas, Rosimeire S.; Moreno, Silvana R.F.; Boasquevisque, Edson M.; Bernardo-Filho, Mario; Lima, Glaydes M.T.; Catanho, Maria T.J.A.

    2002-01-01

    Blood elements labeled with technetium-99m ( 99m Tc) have been used in various procedures in nuclear medicine. We have investigated if phytic acid (PHY) could alter the labeling of blood elements with 99m Tc. Blood was incubated with different concentrations of PHY. Stannous chloride and 99m Tc, as sodium pertechnetate, were added. Blood was centrifuged and plasma (P) and blood cell (BC) were isolated. Samples of P and BC were also precipitated with trichloroacetic acid and centrifuged, and insoluble (IF) and soluble (SF) fractions were separated. The percentages of radioactivity (%ATI) in BC, IF-P and IF-BC were calculated. The %ATI decreased significantly (p 99m Tc with possible undesirable effects, it is relevant to verify the necessity to repeat the examination and to evaluate the increase of the radiation dose to the patient. (author)

  8. Technetium-99m-HMPAO SPECT in patients with hemiconvulsions followed by Todd`s paralysis

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, M.; Sejima, Hitoshi; Ozasa, Hiroshi; Yamaguchi, Seiji [Department of Pediatrics, Shimane Medical University, 89-1 Enya-cho, Izumo, Shimane 693 (Japan)

    1998-02-01

    We performed technetium-99m-hexamethylpropylene- amineoxime (Tc-HMPAO) single photon emission computed tomography in two patients with prolonged hemiconvulsions followed by transient hemiparesis (Todd`s paralysis). In both cases, a prolonged post-ictal cerebral hyperperfusion state of approximately 24 h was observed, even after the neurological deficits had resolved. The cerebral hyperperfusion in both cases was of much longer duration than that in previously reported cases of single and uncomplicated focal seizures. The prolonged cerebral hyperperfusion might have been due to impairment of the cerebrovascular autoregulation in seizures followed by Todd`s paralysis. (orig.) With 2 figs., 9 refs.

  9. Labelling of 5-ethyl-5-phenylbarbituric acid with Technetium-99m: biodistribution study in Swiss mice

    International Nuclear Information System (INIS)

    Simoes, Susana B.E.; Oliveira, Marcia B.N. de; Gutfilen, Bianca; Bernardo-Filho, Mario; Alves, Andreia Coelho; Machado-Silva, Jose R.

    1996-01-01

    The 5-ethyl-5-phenylbarbituric acid (phenobarbital) is used as a sedative, hypnotic and anticonvulsant drug. We decided to label it with technetium-99m. In order to determine the optimal conditions, different concentrations of this drug were incubated with various stannous chloride solutions. Then, 99m Tc was added and chromatography was performed using 0.9% NaCl solution, acetone and n-butyl alcohol as the mobile phase. Using a solution of 0.01 mg/ml stannous chloride and 1.0 mg/ml phenobarbital over 92% of the radioactivity bound to phenobarbital 99m Tc-phenobarbital. In the biodistribution study, 99m Tc-phenobarbital was administered in mice intraperitoneal. The main uptake of the labeled drug was in the liver, blood, kidneys, spleen and stomach. The phenobarbital is also used as anesthetic drug in animals. Earlier studies confirm that this drug can dislocate the adult worms of Schistosoma mansoni to mesenteric vein towards the liver and portal vein, so that we used infected animals, radioactivity was not found in isolated worms and we can conclude that the phenobarbital has an indirect action in relation to the displacement of the worms. (author)

  10. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.; Hamilton, T.; Robison, W.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g -1 dry weight (dw). The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g -1 dw under standard operating conditions

  11. Thymidine kinase enzyme selective imaging radiopharmaceutical. {sup 99m}Tc(CO){sub 3}-Ganciclovir

    Energy Technology Data Exchange (ETDEWEB)

    Gedik, B.; Teksoez, S.; Ichedef, C.; Kilcar, A.Y.; Medine, E.I.; Ucar, E. [Ege Univ., Bornova, Izmir (Turkey). Dept. of Nuclear Applications

    2013-03-01

    The aim of this study is to radiolabel Ganciclovir, known as having selective antiviral properties against thymidine kinase, with technetium tricarbonylcore ({sup 99m}Tc(CO){sub 3}{sup +}) and to investigate the biological behavior of this complex in vitro and in vivo. Commercially provided Ganciclovir (GCV) was radiolabeled with {sup 99m}Tc(CO){sub 3}{sup +}. Initially, optimum radiolabeling conditions were determined by analyzing factors such as temperature, pH and time. Quality control of the radiolabeled compound was performed. The radiolabeling yield was found to be 97%. The {sup 99m}Tc(CO){sub 3}-GCV complex also displayed good in vitro stability during the 24 h period. In vitro cell uptake studies showed that the {sup 99m}Tc(CO){sub 3}-GCV complex is highly uptaken in A-549, PC-3, HeLa cell lines according to the control group {sup 99m}Tc(I)-tricarbonyl core. The knowledge gained from in vivo and in vitro studies of {sup 99m}Tc(CO){sub 3}-GCV could contribute to the development of a new HSV1-tk gene imaging agent. (orig.)

  12. Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

    International Nuclear Information System (INIS)

    Giordano, A.; Meduri, G.; Calcagni, M.L.; Marozzi, P.; Ficola, U.; Vaccaro, A.; Rubini, G.; Attard, M.; Li Puma, M.; Ricci, R.; Corsello, S.

    1999-01-01

    The aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent 201 Tl (74 MBq), 99m Tc-pertechnetate (74 MBq) and 99m Tc-tetrofosmin (555-740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. 201 Tl and 99m Tc-tetrofosmin showed a similar thyroid/background ratio (1.79±0.41 and 1.81±0.47, respectively, P=NS); however, 99m Tc-tetrofosmin showed a higher parathyroid/background ratio than 201 Tl (2.06±0.54 vs 1.79± 0.50, P=0.007). Despite the superior quality of 99m Tc-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%). (orig.)

  13. Use of a new tandem cation/anion exchange system with clinical-scale generators provides high specific volume solutions of technetium-99m and rhenium-188

    International Nuclear Information System (INIS)

    Knapp, F.R. Jr.; Beets, A.L.; Mirzadeh, S.; Guhlke, S.; Univ. of Bonn

    1998-03-01

    In this paper the authors describe the first application of a simple and inexpensive post elution tandem cation-anion exchange column system which is based on generator elution with salts of weak acids such as ammonium acetate instead of saline solution to provide very high specific volume solutions of technetium-99m and rhenium-188 from clinical scale molybdenum-99/technetium-99m generator prepared from low specific activity (n,y) molybdenum-99, and tungsten-188/rhenium-188 generators, respectively. Initial passage of the bolus through a strong cation exchange cartridge converts the ammonium acetate to acetic acid which is essentially not ionized at the acidic pH, allowing specific subsequent amine type (QMA SepPak trademark) anion exchange cartridge column trapping of the microscopic levels of the pertechnetate or perrhenate. Subsequent elution of the anion cartridge with a small volume ( 500 mCi/mL) from the alumina-based tungsten-188/rhenium-188 generator

  14. Contribution of the Technetium-99m-sestamibi (MIBI) scintigraphy in primary hyperparathyroidism to determination of parathyroidectomy

    International Nuclear Information System (INIS)

    Nishida, Takuro; Hayakawa, Katsumi; Nishimura, Kazumasa; Kawakami, Satoshi; Sakamoto, Makoto; Koh, Toshikiyo; Hida, Shuichi

    1999-01-01

    We reviewed retrospectively the 12 patients who underwent parathyroidectomy because of hyperparathyroidism and judged to what degree the Technetium-99m-sestamibi (MIBI) scintigraphy contributed to determination of parathyroidectomy. From the view point that weather parathyroidectomy could be decided without the MIBI scintigraphy, we classified the cases into three groups; great, fair, and poor contribution. We judged 4 cases as great contribution, 5 cases as fair contribution and 3 cases as poor contribution. We concluded that if the MIBI scintigraphy is positive in patients with primary hyperparathyroidism, parathyroidectomy is strongly recommended, because of its high sensitivity and accuracy for detection of parathyroid adenomas and because there were no false-positive cases with the MIBI scintigraphy. (author)

  15. Myocardial perfusion scintigraphy with technetium 99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, C. Amalia; Chacon, Deylis; Llerena, Lorenzo; Torres, Maritza; Garcia, Ernesto Javier; Cabrera, Lazaro Omar

    2006-01-01

    The results of technetium 99 m - methoxy-isobutyl-isonitrile scintigraphy in a one-day protocol: rest - physical or combined stress bicycle plus endovenoous dipyridamole were compared with those of coronary angiography in 20 women referred for the evaluation of pre cordial pain and of the usefulness of myocardial perfusion scintigraphy. The uptake of the radio drug under stress and at rest varied from 93 + - 9 to 94 + - 7 % in the 204 segments with normal uptake under stress, from 67 He articulates it analyzes the reasons or utility of the employment of the radioactive iodine in the diagnosis and treatment of the thyroid affections + - 9 to 75 + - 17 % in the 89 with moderate reduction, and from 33 + - 9 to 64 + - 28 % in the 27 with severe reduction. The qualitative and quantitative uptake analyses coincided in 18 patients. The perfusion scintigraphy and the angiography agreed in 70 % of the patients. It was concluded that the myocardial perfusion scintigraphy with technetium 99 -MIBI contributes to the diagnosis of the coronary artery disease in women

  16. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Science.gov (United States)

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  17. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    Science.gov (United States)

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS SSS >9 were compared to patients with SSS SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  18. Somatostatine analogs marked with 99m-TC

    International Nuclear Information System (INIS)

    Obenaus, E; Crudo, J; Edreira, M; Castiglia, S.G. de

    2003-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr 3 Octreotide(TOC) peptides when labeling with 99m Tc by an indirect method using S-Benzoyl- mercaptoacetyl triglycine (MAG3) and hydrazino nicotinamide (HYNIC) as chelating agents. The synthesis of RC160 with S-Benzoyl MAG3 and TOC with HYNIC, for labeling with 99m Tc are also described. The conjugates were prepared on a small scale and labeled with the radionuclide using tricine as coligands for HYNIC conjugates. Chromatographic studies were performed using an HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labeled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labeling with 99m Tc using tricine as coligand although higher stability should be found for ternary coligands compared to tricine (Au)

  19. Accuracy of 99Molybdenum assays in /sup 99m/Technetium solutions

    International Nuclear Information System (INIS)

    Williams, C.C.; Kereiakes, J.G.; Grossman, L.W.

    1981-01-01

    A study was performed to determine the accuracy of 99 Mo measurements using three commercial dose calibrators with their 99 Mo assay shields. One 99 Mo assay shield allowed excessive penetration by the lower energy /sup 99m/Tc photons, resulting in the calibrator's falsely high interpretation of the activity of 99 Mo present in the high-activity /sup 99m/Tc eluates. All three calibrators performed adequately with a National Bureau of Standards 99 Mo standard in equilibrium with /sup 99m/Tc. By using low-activity aliquots of 99 Mo and /sup 99m/Tc, a low-level linearity test was performed. Only one of the calibrators was found to reflect accurately the activity of 99 Mo present under all conditions tested

  20. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  1. Technetium-99m extraction and transport across tri-n-octylamine-xylene based supported liquid membranes

    International Nuclear Information System (INIS)

    Ashraf Chaudry, M.; Ahmad, B.

    1996-01-01

    The nuclear properties of 99m Tc radionuclide are ideal for organ imaging. Study of the technetium transport across supported liquid membranes has been performed to get data for its separation from other elements. Tri-n-octylamine diluted in xylene was used to constitute the liquid membranes, supported in polypropylene microporous films. Stripping on the product solution side was performed with dilute NaOH solutions. The effect of sulphuric acid, nitric acid and hydrochloric acid in the feed on transport of 99m Tc as TcO 4 - ions has been studied. The permeability of the given ions determined from kinetic activity data has been found to be in the order of PH 2 SO 4 >PHCl>PHNO 3 . The flux values have been calculated based on this permeability data. The increase in carrier concentration has shown an increase in flux and permeability values to a given optimum concentration. The increase in temperature has been found to reduce the transport of Tc ions. The optimum conditions for transport of 99m Tc for the given acid concentration have been determined. Mechanism of Tc ion transport has also been provided based on chemical reactions involved at the membrane interfaces and uptake of Tc ions by the membrane. MoO 4 2- ions do not permeate through membrane under optimum conditions of transport for TcO 4 2 - ions from H 2 SO 4 solution. (author). 12 refs., 20 figs., 1 tab

  2. Noninvasive imaging of malignant tumors using laminin peptide fragments YIGSR labeled with Technetium-99m

    International Nuclear Information System (INIS)

    Qin, G.M.; Zhang, Y.X.; Hu, J.; An, R.; Gao, Z.R.; Cao, G.X.; Hnatowich, D.J.

    2002-01-01

    The radiopharmaceuticals that localize specifically at certain sites (such as peptides directed against receptors expressed on tumor cells or antibodies with high binding affinities for bacterial determinants) may be expected to display greater specificity of localization. Peptides, which diffuse rapidly into target lesions and clear rapidly elsewhere, may be expected to enjoy a pharmacokinetic advantage over those, such as antibodies, which accumulate and clear more slowly. The laminin peptide fragments YIGSR is known to bind to a 67-kDa laminin receptor. This receptor is understood to be expressed at higher than normal levels in malignant tumor cells, particularly those of breast and colon carcinomas. Methods 1 peptide conjugation and labeling A 2.5 mg/mL solution of YIGSR in 0.1 M N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid (HEPES) buffer, pH8.0, and a fresh 10mg/mL solution of NHS-S-acetyl-MAG 3 in dimethylformamide dried over molecular sieve were prepared. 2 biodistribution and imaging studies A colony of KM mice (15-20g) were inoculated with 1x10 6 Ehrlich (breast) carcinoma tumor cells in the right thigh, and the tumors were allowed to grow for 6-7 days to a size of 1.0-1.5 cm in diameter. Biodistribution studies were performed in 40 KM mice after 50 μCi per mouse of 99m Tc-labeled YIGSR were injected intravenously. A total of 10 mice were injected intravenously in the tail vein with 1-2 mCi of 99m Tc-labeled YIGSR, immobilized with ketamine hydrochloride and imaged periodically from 0.5 hr to 24 hr with a gamma camera. The identical imaging procedure was also performed in mice with sterile infection/inflammation lesions to evaluate the specificity. Results Essentially complete conjugation was achieved by reverse-phase Sep-Pak C18 chromatography analysis. The highest accumulation of label was in the kidney first, with the liver and small bowel next. The injected activity localized in the lesion as early as 15 min and reached a saturation value at 3

  3. Detection of axillary lymph node metastases in breast carcinoma by technetium-99m sestamibi breast scintigraphy, ultrasound and conventional mammography

    International Nuclear Information System (INIS)

    Lam, W.W.M.; Yang, W.T.; Chan, Y.L.; Stewart, I.E.T.; Metreweli, C.; King, W.

    1996-01-01

    Axillary lymph node status is important in the staging of breast carcinoma. To evaluate the accuracy of technetium-99m sestamibi breast scintigraphy in detecting metastatic axillary lymph nodes as compared with other accepted imaging modalities, we performed 99m Tc-sestamibi breast scintigraphy, conventional mammography and ultrasound in 36 patients with primary untreated breast cardinoma. With histopathology as the gold standard, 99m Tc-sestamibi breast scintigraphy was found to yield true-positive results in 7 of 11 cases (64%) of axillary lymph nodes metastases and true-negative results in 18 of 20 cases (90%); it has an accuracy of 81%, a positive predictive value of 77.8% and a negative predicive value of 81.8%. (orig.)

  4. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by 99m technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    International Nuclear Information System (INIS)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian

    2014-01-01

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a 99m technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of 99m technetium sulfur colloid SPECT/CT imaging in this rare condition.

  5. The use of technetium-99m-di-isopropyl-iminodiacetic acid imaging in the demonstration of a biliary-bronchial fistula

    International Nuclear Information System (INIS)

    Savitch, I.; Esser, J.D.; Levin, J.; Krige, L.P.; Kew, M.C.

    1984-01-01

    A case is described in which technetium-99m-di-isopropyl-iminodiacetic acid imaging was used to trace the passage of bile from its site of leakage into an amoebic liver abscess, through a fistulous tract connecting the liver abscess with an abscess in the right lower lobe of the lung, and into the upper respiratory tract

  6. Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody

    Energy Technology Data Exchange (ETDEWEB)

    Munz, D L; Sandrock, D; Emrich, D [Goettingen Univ. (Germany). Abt. fuer Nuklearmedizin; Morguet, A J; Heim, A; Sold, G; Figulla, H R; Kreuzer, H [Goettingen Univ. (Germany). Abt. fuer Kardiologie und Pulmonologie

    1991-12-01

    Immunoscintigraphy with a technetium-99m murine monoclonal IgG{sub 1} antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE. (orig.).

  7. Radioimmunoimaging of subacute infective endocarditis using a technetium-99m monoclonal granulocyte-specific antibody

    International Nuclear Information System (INIS)

    Munz, D.L.; Sandrock, D.; Emrich, D.; Morguet, A.J.; Heim, A.; Sold, G.; Figulla, H.R.; Kreuzer, H.

    1991-01-01

    Immunoscintigraphy with a technetium-99m murine monoclonal IgG 1 antibody directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen was performed with 20 patients with suspected subacute infective endocarditis (SIE) and 6 controls with suspected inflammatory/infectious disease elsewhere in the body. Immunoscintigraphy and echocardiography localised SIE in 11 of 15 patients in whom the disease could be confirmed. In 4 patients with validated SIE, the immunoscan was abnormal, and the echocardiogram was normal. In another 4 patients, the result was exactly the opposite. These findings suggest that the combination of immunoscintigraphy and echocardiography improves diagnostic efficacy in patients with suspected SIE. (orig.)

  8. Technetium-99m sestamibi leg scintigraphy for non-invasive assessment of propionyl-l-carnitine induced changes in skeletal muscle metabolism

    International Nuclear Information System (INIS)

    Cittanti, C.; Colamussi, P.; Giganti, M.; Orlandi, C.; Uccelli, L.; Manfrini, S.; Azzena, G.; Piffanelli, A.

    1997-01-01

    Carnitine derivatives, such as propionyl-l-carnitine (PLC), have been shown to improve walking distance in patients with obstructive peripheral artery disease (PAOD). The aim of this study was to ascertain whether technetium-99m sestamibi leg scintigraphy may be a useful tool in the evaluation of changes in skeletal muscle metabolism induced by chronic therapy with PLC. Twenty patients with clinical and instrumental evidence of PAOD were randomly assigned to a 3-month period of therapy with either PLC or placebo. Rest 99m Tc-sestamibi leg scintigraphy and echo-Doppler sonography were performed on all subjects immediately before and upon completion of the treatment period. At the end of the protocol the following results were observed in patients who underwent PLC administration: (a) a significant increase in both thigh and calf 99m Tc-sestamibi uptake, in comparison with baseline values (P 99m Tc-sestamibi was demonstrated without any apparent change in regional blood flow. This fact, if proven in further studies, may suggest a role for this tracer as a non-invasive probe of tissue bioenergetics. (orig.). With 4 figs., 4 tabs

  9. In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients

    International Nuclear Information System (INIS)

    Del Vecchio, S.; Ciarmiello, A.; Potena, M.I.; Carriero, M.V.; Mainolfi, C.; Botti, G.; Thomas, R.; Cerra, M.; D'Aiuto, G.; Tsuruo, T.; Salvatore, M.

    1997-01-01

    Technetium-99m sestamibi is a transport substrate recognised by the multidrug-resistant P-glycoprotein (Pgp). To test whether 99m Tc-sestamibi efflux is enhanced in breast carcinomas overexpressing Pgp, we determined the efflux rates of 99m Tc-sestamibi and Pgp levels in tumours from 30 patients with untreated breast carcinoma. Patients were intravenously injected with 740 MBq of 99m Tc-sestamibi and underwent a 15-min dynamic study followed by the acquisition of static planar images at 0.5, 1, 2 and 4 h. Tumour specimens were obtained from each patient 24 h after 99m Tc-sestamibi scan and Pgp levels were determined using 125 I-MRK16 monoclonal antibody and in vitro quantitative autoradiography. All breast carcinomas showed high uptake of 99m Tc-sestamibi and data from region of interest analysis on sequential images were fitted with a monoexponential function. The efflux rates of 99m Tc-sestamibi, calculated from decay-corrected time-activity curves, ranged between 0.00121 and 0.01690 min -1 and were directly correlated with Pgp levels measured in the same tumours (r=0.62; P 99m Tc-sestamibi efflux from tumours of group A was 2.7 times higher than that observed in tumours of group B (0.00686 ±0.00390 min -1 vs 0.00250 ±0.00090 min -1 , P 99m Tc-sestamibi showed a sensitivity and a specificity of 80% and 95%, respectively. In conclusion, the efflux rate of 99m Tc-sestamibi may be used for the in vivo identification of the multidrug resistant (MDR1) phenotype in untreated breast cancer patients. (orig.). With 7 figs., 3 tabs

  10. Preparation and in vivo biological investigations on a novel radioligand for bone scanning: technetium-99m-labeled zoledronic acid derivative

    International Nuclear Information System (INIS)

    Lin Jianguo; Qiu Ling; Cheng Wen; Luo Shineng; Ye Wanzhong

    2011-01-01

    Introduction: To enable imaging at an earlier time after injection, a radiopharmaceutical with higher affinity for bone, larger ratio of bone-to-soft tissue uptake and more rapid clearance from blood is required. The nature of diphosphonic acid is a key factor to determine the advantages of the radiopharmaceuticals. The purpose of this study is to optimize the linker chain between the imidazolyl and geminal diphosphonate group in the zoledronic acid (ZL) to develop novel single photon emission computed tomography (SPECT) bone imaging agent. Methods: A novel ZL derivative, 1-hydroxy-3-(1H-imidazol-1-yl)propane-1,1-diyldiphosphonic acid (IPrDP), was successfully prepared and labeled with 99m Tc in a high labeling yield. Biodistribution of 99m Tc-IPrDP and 99m Tc-ZL in normal mice were studied and compared. SPECT bone scanning was performed on the rabbit and a series of dynamic and static images were recorded by Philips SKY Light emission computed tomography. Results: In the biodistribution studies, 99m Tc-IPrDP exhibits significant advantages on the bone resorption and the clearance from soft tissues compared with 99m Tc-ZL. Kinetics of blood clearance in mice showed that T 1/2α and T 1/2β of 99m Tc-IPrDP were 1.47 min and 46.47 min, while those of 99m Tc-ZL were 2.28 and 52.63 min respectively. Excellent images of the rabbit skeleton can be quickly obtained for 99m Tc-IPrDP, which was faster than 99m Tc-ZL and the clinically widely used bone imaging agent 99m Tc-MDP (technetium-99m labeled with methylenediphosphonate). Conclusions: 99m Tc-IPrDP possesses excellent characteristics for the potential application as a novel bone scanning agent.

  11. Technetium-99 in lobsters from the western Irish sea

    International Nuclear Information System (INIS)

    Fegan, Mary

    1999-05-01

    Technetium-99, the most important radionuclide of technetium release to the environment, is a pure beta emitter with a half-life of 2.13 x 10(5) years. It behaves conservatively in seawater and is likely to remain available to biota for a long time. The dominant and most stable form of technetium in oxygenated seawater is the pertechnetate ion, Tco4. The principle source of radionuclide contamination of the Irish Sea has been the liquid waste discharges of low level radionuclide effluent from the spent nuclear fuel reprocessing plant at Sellafield on the Cumbria Coast. In 1994 the annual discharge authorization limit for 99Tc was increased from 10 TBq to 200 TBq. Lobster concentrates 99Tc to a high degree with concentration factors of 1x 10(3) reported in the literature. The mean 99Tc activity concentrations in lobsters caught close to Sellafield were reported to have risen by a factor of 20 in 2 years from 390 Bq/kg (wet weight) in 1993 to 8300 Bq/kg (wet weight) in 1995. This study was undertaken to determine the 99Tc activity concentration in lobsters from the western Irish Sea. Lobsters were collected from the east and north east coasts of Ireland over the period June 1997 to July 1998 and analysed using a radioanalytical method which was based on the anion-exchange seperation of technetium as pertechnetate. A gas-flow proportional counter was used to measure to 99Tc activity concentration in each sample. Technetium-99 activity concentrations were measured in the muscle from the tail, the right and the left claws and also in the green gland, the hepatopancreas and the cardiac fore-gut. The results of the measurements showed, as expected, that the 99Tc activity concentrations were not as high as those in the samples from the Cumbrian coast. The mean 99Tc activity concentrations, over the sampling period, in the tail, right and left claw muscles were 214, 124 and 136 BQ/kg (wet weight) respectively. The mean 99Tc activity concentrations in the green gland

  12. Technetium-99 in the Irish marine environment

    Energy Technology Data Exchange (ETDEWEB)

    Smith, V.; Fegan, M.; Pollard, D.; Long, S.; Hayden, E.; Ryan, T.P

    2001-07-01

    Technetium-99 activity concentrations in seawater and biota from Irish coastal waters are presented. Time series measurements of {sup 99}Tc in seawater and Fucus vesiculosus from the western Irish Sea show that activity concentrations have increased in line with the increase in discharges of {sup 99}Tc from Sellafield. The peak in activity concentrations in both seawater and Fucus vesiculosus occurred in 1997 approximately two years after the peak in {sup 99}Tc discharges. The highest activity concentration recorded in Fucus vesiculosus showed a 29-fold increase over the mean concentration for the period 1988-1993. Technetium-99 activity concentrations were measured in fish, lobsters, prawns, mussels and oysters landed at major fishing ports on the east and northeast coasts of Ireland between 1996 and 1998. Concentration factors for {sup 99}Tc in the brown seaweed Fucus vesiculosus and certain species of fish, crustaceans and molluscs from the Irish Sea were estimated. In general, these concentration factors were higher than those in the literature which were derived from laboratory studies, but agreed well with values which were based on field studies. The mean committed effective doses to Irish typical and heavy seafood consumers due to {sup 99}Tc in the period 1996-1998 were 0.061 and 0.24 {mu}Sv, respectively.

  13. Technetium-99m radiolabeling of a recombinant dermonecrotic protein (recLiD1) from the Loxosceles venom for biodistribution study

    International Nuclear Information System (INIS)

    Valadares, D.; Felicori, L.; Olortegui, C.C.; Simal, C.; Gouvea dos Santos, R.

    2007-01-01

    In the present study the recombinant form (recLiD1) of a dermonecrotic protein present in the Brazilian brown spider Loxosceles intermedia venom was labeled with technetium-99m using stannous chloride and sodium borohydride as reducing agents. 99mTc-recLiD 1 kept its biological activity evoking dermonecrotic activity in rabbits. In vivo biodistribution in mice with the radiolabeled recLiD 1 showed high kidney uptake followed by stomach and liver uptakes. Also, we can see that 20% of toxin remaining in the skin after 120 min and once absorbed, 99mTc-recLiD 1 is rapidly cleared from the blood with long-lasting. We also observed one displacement of 99mTc-recLiD 1 by one monoclonal antibody raised against L. intermedia venom that indicates specific interaction with kidney tissue. (author)

  14. Clearance of technetium-99m-DTPA and HRCT findings in the evaluation of patients with Idiopathic Pulmonary Fibrosis

    Directory of Open Access Journals (Sweden)

    Karkavitsas Nikolaos

    2006-02-01

    Full Text Available Abstract Background Clearance of inhaled technetium-labeled diethylenetriamine pentaacetate (99mTc-DTPA is a marker of epithelial damage and an index of lung epithelial permeability. The aim of this study was to investigate the role of 99mTc-DTPA scan in patients with Idiopathic Pulmonary Fibrosis (IPF. Our hypothesis is that the rate of pulmonary 99mTc-DTPA clearance could be associated with extent of High Resolution Computed Tomography (HRCT abnormalities, cell differential of bronchoalveolar lavage fluid (BALF and pulmonary function tests (PFTs in patients with IPF. Methods We studied prospectively 18 patients (14 male, 4 female of median age 67yr (range 55–81 with histologically proven IPF. HRCT scoring included the mean values of extent of disease. Mean values of these percentages represented the Total Interstitial Disease Score (TID. DTPA clearance was analyzed according to a dynamic study using a Venticis II radioaerosol delivery system. Results The mean (SD TID score was 36 ± 12%, 3 patients had mild, 11 moderate and 4 severe TID. Abnormal DTPA clearance half-time (t1/2 Conclusion Our data suggest that 99mTc-DTPA lung scan is not well associated with HRCT abnormalities, PFTs, and BALF cellularity in patients with IPF. Further studies in large scale of patients are needed to define the role of this technique in pulmonary fibrosis.

  15. Synthesis, radiochemistry and biological evaluation of a new somatostatin analogue (SDZ 219-387) labelled with technetium-99m

    International Nuclear Information System (INIS)

    Maina, T.; Stolz, B.; Albert, R.; Bruns, C.; Koch, P.; Maecke, H.

    1994-01-01

    A new derivative of octreotide SDZ 219-387 [PnAO-(D)Phe 1 -octreotide] was synthesized, which binds specifically and with high affinity to somatostatin receptors in vitro (pK i =9.79±0.16). This new somatostatin analogue chelates technetium-99m under mild labelling conditions in good yields. The resulting [ 99m Tc]SDZ 219-387 was stable up to 6 h after labelling and could be isolated in a pure radiochemical and chemical form by high-perfomance liquid chromatographic purification. The intravenous administration of purified [ 99m Tc]SDZ 219-387 revealed that the radioligand was rapidly cleared from circulation, and tumour uptake of 0.38% ID/g was observed at 1.5 h post injection. [ 99m Tc]SDZ 219-387 specifically interacted with somatostatin binding sites on the tumour. However, the radioligand is highly lipophilic and excreted mainly through the hepatobiliary system. As a consequence, [ 99m Tc]SDZ 219-387 exhibits increased background activity and therefore is not appropriate for the in vivo visualization of somatostatin receptor-positive tumours and/or their metastases in the abdomen. (orig.)

  16. Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents

    International Nuclear Information System (INIS)

    Bellande, Emmanuel; Comazzi, Veronique; Laine, Jacques; Lecayon, Michele; Pasqualini, Roberto; Duatti, Adriano; Hoffschir, Didier

    1995-01-01

    The symmetrical complexes [ 99m Tc][TcN(R 2 PS 2 ) 2 ] [R = CH 3 , CH 2 CH 3 , CH 2 CH 2 CH 3 , CH 2 (CH 3 ) 2 ], and the unsymmetrical complex [ 99m Tc][TcN(Me 2 PS 2 )(Et 2 PS 2 )] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R 2 PS 2 ]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding 99 Tc-analogs prepared, at macroscopic level, by reacting the complex [ 99 TcNCl 4 ] [n-Bu 4 N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS 2 group. In vitro studies showed that these radiopharmaceuticals are stable in solution and that their chemical identity was not altered after incubation with rat blood. Biodistribution studies have been carried out in rats and primates. The results demonstrate that these compounds are significantly retained into the brain of these animals for a prolonged time. Planar gamma camera images have been obtained in monkeys showing a good visualization of the cerebral region. However, the existence of persistent blood activity yields a brain/blood ratio lower than that observed with other 99m Tc-based brain perfusion imaging agents

  17. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K. E-mail: k_tagami@nirs.go.jp; Uchida, S.; Hamilton, T.; Robison, W

    2000-07-15

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g{sup -1} dry weight (dw). The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g{sup -1} dw under standard operating conditions.

  18. 99m-technetium tetrofosmin and 99mTc-methylene diphosphonate in pre-surgical breast cancer

    International Nuclear Information System (INIS)

    Piperkova, E.; Gavrilov, I.; Timcheva, K.; Garanina, Z.; Aleksandrova, E.; Katerinski, K.; Dimitrova, M.

    2004-01-01

    data was compared with mammography and histological findings. Semi-quantitative analysis was carried out by drawing regions of interest over the lesion and background so as to calculate T/B (tumour / background) or N/B (node / background) ratios. With Tc-99m TF, a total of 25 true positive breast and 11 lymph node lesions could be identified. Primary breast lesion was detected in one patient having palpable lymph node but non-palpable breast lump. Seven patients showed diffuse non-homogeneous uptake of TF with T/B ratio less than 1.4. T/B and N/B ratio of >1.45 was considered to represent malignancy. Tc-99m MDP SMM did not show any false negative result. In the early images, the tumour was recognized as a well-defined focus of increased uptake but decreased in intensity in later images. On WBBS painless bone metastases were detected in two patients thus changing stage from IIa to IV. Tc-99m TF SMM was positive in 6 patients in stage 1, 8 in IIa, 1 in I?b, 9 in IIIa and 2 in stage IV patients. All patients of stage IIIa received neo-adjuvant chemotherapy, using FEC protocol (5-Fluorouracil, Epirubicin/Farmarubicin and Cyclophosphamide). After completion of four courses, 4 patients did not show the tracer uptake on repeat SMM. Our data of Tc-99m TF SMM showed sensitivity of 97.3%, specificity 98.3%, accuracy 98%, PPV 97% and NPV of 98%. The results of this study confirm the utility of Tc-99m TF SMM in the management of patients with breast lesions. This radiopharmaceutical may be a convenient alternative to 99mTc-sestamibi because no boiling is required in its preparation. In conclusion, our study suggests that 99mTc-TF and 99mTc-MDP scintigraphies are useful tools to stage the breast cancer and predict prognosis. (author)

  19. Clinical evaluation of salivary gland imaging with technetium-99m pertechnetate 43 cases

    International Nuclear Information System (INIS)

    Huang Daming

    1989-01-01

    Salivary gland imaging in 36 patients with benign or malignant tumor all showed the size, extent and location of tumor in parotid glands. There was no pseudonegative diagnosis in salivary gland imaging, but in sailography there were three cases with pseudo-negative diagnosis. The authors believe salivary gland imaging with Technetium-99m pertechnetate although is nonspecific for Warthin's tumor of parotid gland, and is also not able to differentiate malignant tumor from benign tumor of salivary gland, but radionuclide examination is a safe and simple diagnostic technnique and proves to have greater sensitivity in demonstrating abnormalities of salivary gland than that of routine sailography. Contrast salivarry gland imaging with sailography one can differentiate inflammation from tumor and benign from malignant tumor

  20. Study of factors that interfere in the labelling process of erythrocytes and plasma proteins with Technetium-99m

    International Nuclear Information System (INIS)

    Gutfilen, Bianca

    1989-01-01

    The labelling of red blood cells (RBC) with technetium-99m (Tc-99m) depends on several factors, as the stannous ion (Sn++) concentration, time, temperature, the presence of plasma proteins (PP) and others. However the Sn++ concentration seems to be the most important factor; probably because the uptake of this reducing agent by RBC is limited. The excess of Sn++ in extracellular medium can determine the labelling of PP. the modifications of RBC at 50 deg C described in the literature, the possibility of labelling RBC with Tc-99m at this temperature and experimental results obtained made it possible to perform spleen selective scintigraphy through a simple technique with few manipulations. The effect of gentamicin, nifedipine and verapamil in the labelling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca++ and Sn++. The results show that, under some conditions, these drugs are capable to alter this Tc-99m incorporation. The modification of the ionic distribution determined by these drugs or the blockage of Sn++ and/or Tc-99m or the fact that they bind theirselves to plasma proteins, or the possibility of the labelling of these drugs, are factors that can interfere in the labelling process of red blood cells and plasma proteins with Tc-99m. (author)

  1. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Maria Regina de Macedo; Ribeiro, Camila Godinho; Santos-Filho, Sebastiao David; Neves, Rosane de Figueiredo; Catanho, Maria Teresa Jansem de Almeida [Universidade Federal do Rio Grande do Norte, Natal, RN (Brazil). Centro de Ciencias da Saude]. E-mail: mariaregina.mr@terra.com.br; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Dept. de Biofisica e Biometria

    2007-09-15

    The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC) is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC) and plasma proteins are labeled with technetium-99m (Tc-99m) and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI) was determined. The results show a statistical (p<0.05) alteration in the %ATI on blood compartments and on the insoluble fractions of plasma and BC. Probably, this extract would have chemical compounds with oxidant properties. (author)

  2. An aqueous extract of Vitex agnus castus alters the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Costa, Maria Regina de Macedo; Ribeiro, Camila Godinho; Santos-Filho, Sebastiao David; Neves, Rosane de Figueiredo; Catanho, Maria Teresa Jansem de Almeida; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2007-01-01

    The development of experimental assays to study properties of herbal medicine is worthwhile. Vitex agnus castus (VAC) is utilized in popular medicine and some actions have been attributed to its extract. Blood cells (BC) and plasma proteins are labeled with technetium-99m (Tc-99m) and have been used in nuclear medicine, as in basic research. This procedure uses a reducing agent and stannous ion is utilized. There are reports that drugs can alter this labeling process. The aim of this work was to evaluate the influence of an aqueous extract of VAC on the labeling of blood constituents with Tc-99m. Blood was incubated with VAC, stannous chloride and Tc-99m, as sodium pertechnetate, and centrifuged. Samples of BC and plasma were separated, aliquots of BC and plasma were also precipitated with trichloroacetic acid to obtain soluble and insoluble fractions and the percentage of radioactivity (%ATI) was determined. The results show a statistical (p<0.05) alteration in the %ATI on blood compartments and on the insoluble fractions of plasma and BC. Probably, this extract would have chemical compounds with oxidant properties. (author)

  3. Sup(99m)Tc compounds for diagnostic purposes

    International Nuclear Information System (INIS)

    Cifka, J.; Budsky, F.

    1980-01-01

    The applications of sup(99m)Tc in nuclear medicine are discussed, such as sodium pertechnetate in thyroid and brain scintigraphy, complex compounds in lungs and liver diao.nosis. Technetium generators are classified according to the method of separating sup(99m)Tc from 99 Mo. Adsorption generators are used, molybdate-99 is adsorbed on an Al 2 O 3 -packed column while pertechnetate-99m is eluted with 0.9% NaCl solution. Also used is continuous pertechnetate-99m extraction with methyl ethyl ketone from 0.5 M potassium molybdate and 2.5 M of potassium carbonate. The manufacture is described of kits for sup(99m)Tc radiopharmaceuticals preparation, eg., Diagos I, a gluconate complex, a lyophilisate for sup(99m)Tc-sodium pyrophosphate injections, a diagnostic kit for lung scintiscanning. (H.S.)

  4. Comparison of the accumulation and efflux kinetics of technetium-99m sestamibi and technetium-99m tetrofosmin in an MRP-expressing tumour cell line

    International Nuclear Information System (INIS)

    Utsunomiya, K.; Su, Z.-F.; Ichise, M.; Ballinger, J.R.; Piquette-Miller, M.; Tang, W.; Rauth, A.M.

    2000-01-01

    The potential clinical use of technetium-99m labeled sestamibi (Tc-MIBI) and tetrofosmin (Tc-Tfos) to image tumours is currently being evaluated. In this study, the accumulation and efflux of Tc-MIBI and Tc-Tfos in the nasopharyngeal carcinoma cell line CNE-1 were examined in the presence or absence of various inhibitors of P-glycoprotein (PGP) and/or multidrug resistance associated protein (MRP) activity [GG918, PSC833, verapamil (Vrp), cyclosporin A (CsA) and buthionine sulfoximine (BSO)]. Reverse-transcriptase polymerase chain reaction analysis and immunodetection of the CNE-1 cells detected expression of MRP, MRP1 and MRP2 but not PGP. Tc-MIBI and Tc-Tfos accumulation was increased (P 2 times greater than for Tc-MIBI). However, no qualitative differences in inhibitors were seen between Tc-MIBI and Tc-Tfos. These results suggest that both Tc-MIBI and Tc-Tfos are substrates for the MRP transporter and that PSC833, Vrp, CsA and BSO but not GG918 can inhibit MRP activity. These results indicate that Tc-MIBI and Tc-Tfos may be suitable imaging agents for detecting MRP-mediated drug resistance in human cancers. (orig.)

  5. Technetium-99m-dimethylglyoxime ([sup 99m]Tc-DMG) as renal imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Adonaylo, V.N. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales Buenos Aires Univ. (Argentina). Dept. de Ciencias Biologicas); Stahl, Adriana; Pomilio, A.B.; Vitale, A.A. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales); Canellas, C.O. (Buenos Aires Univ. (Argentina). Facultad de Ciencias Exactas y Naturales Comision Nacional de Energia Atomica, Buenos Aires (Argentina))

    1993-06-01

    Dimethylglyoxime (DMG) labelled with [sup 99m]Tc is presented as a renal imaging agent. The behaviour of this complex was analysed at different pH by means of UV spectral data and using DMG-calcium chloride as a reference complex. Biokinetic data were evaluated in two biological models, Sprague-Dawley rats and Didelphis albiventris argentine opossum. Biodistribution in rats demonstrated fast and specific renal excretion. Time-activity values over both kidneys could be quantified for this complex. Renographic studies led to mean time-to maximum values on twelve assays of 2.0 [+-] 0.1 min and a mean relative function of 53.0 [+-] 2.3 and 47.0 [+-] 3.2 for right and left kidneys, respectively. [sup 99m]Tc-DMG showed specificity for the renal excretion pathway and therefore seems to be a very useful radiopharmaceutical for renal function studies. (Author).

  6. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    Science.gov (United States)

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  7. Extramedullary pulmonary hematopoiesis causing pulmonary hypertension and severe tricuspid regurgitation detected by {sup 99m} technetium sulfur colloid bone marrow scan and single-photon emission computed tomography/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Syed Zama; Clarke, Michael John; Kannivelu, Anbalagan; Chinchure, Dinesh; Srinivasan, Sivasubramanian [Dept. of Diagnostic Radiology, Khoo Teck Puat Hospital, Singapore (Singapore)

    2014-06-15

    Extramedullary pulmonary hematopoiesis is a rare entity with a limited number of case reports in the available literature only. We report the case of a 66-year-old man with known primary myelofibrosis, in whom a {sup 99m}technetium sulfur colloid bone marrow scan with single-photon emission computed tomography (SPECT)/CT revealed a pulmonary hematopoiesis as the cause of pulmonary hypertension and severe tricuspid regurgitation. To the best of our knowledge, this is the first description of {sup 99m} technetium sulfur colloid SPECT/CT imaging in this rare condition.

  8. Morphologic alterations on red blood cells labeled with technetium-99m: the effect of Mentha crispa L. (hortela) extract

    International Nuclear Information System (INIS)

    Santos-Filho, S.D.; Dire, G.L.; Lima, E.; Pereira, M.; Bernardo-Filho, M.

    2002-01-01

    The use of natural products, as medicinal plants, is very frequent in the world. Mentha crispa L. (M. crispa) is utilized in herbal medicine. Blood elements labeled with technetium-99m (99mTc) are used in nuclear medicine procedures and this labeling process may be altered by drugs. We have investigated the possibility of M. crispa extract being capable to alter the labeling of blood elements with 99mTc. Blood was incubated with M. crispa extract in various concentrations (6.25, 12.5, 25, 50 and 100%). Stannous chloride solution and Tc-99m, as sodium pertechnetate, were added. Blood was centrifuged and plasma (P) and blood cells (BC) were isolated. Samples of P and BC were also precipitated, centrifuged and insoluble (IF) and soluble (SF) separated. The percentage of radioactivity (%ATI) in BC, IF-P and IF-BC was calculated. Histological evaluations of the red blood cells (RBC) were performed with blood samples treated with various concentrations of M. Crispa L. and the morphology of the RBC was observed under optical microscope. Important morphological alterations expressed by mean of the perimeter/area of the RBC treated with M. crispa: 6.25% (0.67 ± 0.02), 12.5% (0.77 ± 0.03), 25% (0.73 ± 0.04), 50% (0.76 ± 0.04), 100% (0.69 ± 0.08) and the control cells (0.67 ± 0.05). The %ATI decreased: (i) on BC from 97.3 ± 1.92 to 60.0 ± 2.44; (ii) on IF-P from 74.8 ± 3.78 to 9.99 ± 3.61; (iii) on IF-BC from 88.6 ± 5.41 to 58.4 ± 11.55. The perimeter/area of the RBC showed significant differences (P>0.01) when compared 6.25% and 12.5%, and when compared 6.25% and 50% of M. Crispa L. extract. These findings could also justify the decrease of the labeling of BC with 99mTc in presence of M. Crispa extract

  9. The role of technetium-99m methoxyisobutylisonitrile scintigraphy in the differential diagnosis of cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Mezosi, E.; Bajnok, L.; Sztojka, I.; Szabo, J.; Leovey, A.; Kakuk, G.; Nagy, E. [Department of Medicine, University Medical School, Debrecen (Hungary); Gyory, F. [Department of Surgery, University Medical School, Debrecen (Hungary); Varga, J.; Galuska, L. [Nuclear Medicine Centre, University Medical School, Debrecen (Hungary)

    1999-08-01

    Various diagnostic techniques have been successfully used in the clinical management of cold nodules; however, the decision on whether to employ surgery or a conservative treatment is not always easy. This study was designed to appraise the diagnostic value of technetium-99m methoxyisobutylisonitrile (MIBI) scintigraphy in the assessment of cold nodules detected using {sup 99m}Tc-pertechnetate. Fifty-two patients were included in the study. All had already been selected for surgery, based on their clinical and laboratory findings, including fine-needle aspiration biopsy. The total number of cold nodules on {sup 99m}Tc-pertechnetate scans was 59. The thyroid scan was performed 20-40 min after i.v. injection of 400 MBq of {sup 99m}Tc-MIBI. Uptake of MIBI in thyroid nodules was compared with that in the surrounding normal thyroid tissue, and a score of between 0 and 3 was assigned to each nodule as follows: 0, cold; 1, decreased; 2, equal; 3, hot. Definitive histology revealed nodular goitre in 24 cases, adenoma in 19, thyroiditis in 1, differentiated cancer in 12, medullary cancer in 2, and anaplastic cancer in 1. None of the degenerative nodules were hot on MIBI scan, while the adenomas showed a variety of MIBI imaging patterns, most frequently the score 3 pattern. In the diagnosis of differentiated thyroid cancer the sensitivities of score 3 and score 2+3 MIBI uptake patterns were 83% (10/12) and 100%, respectively. The score 3 MIBI uptake pattern had a specificity of 100% and a positive predictive value of 100% with respect to thyroid (benign and malignant) neoplastic diseases, whereas a specificity of 72% and a positive predictive value of 43% were observed in the detection of differentiated cancer. After a cold nodule had been detected using {sup 99m}Tc-pertechnetate, a second scan with high MIBI uptake increased by 7.8 times the probability that this nodule would be a differentiated cancer. In conclusion, {sup 99m}Tc-MIBI scintigraphy is a useful method in the

  10. Resting technetium-99m methoxyisobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Cuocolo, A.; Maurea, S.; Pace, L.; Nicolai, E.; Nappi, A.; Imbriaco, M.; Trimarco, B.; Salvatore, M.

    1993-01-01

    We studied 19 patients with angiographically proven coronary artery disease and left ventricular dysfunction (ejection fraction 33%±8%) by resting technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) and rest-redistribution thallium-201 cardiac imaging. Thallium and 99m Tc-MIBI studies were visually analysed. Of 285 segments, 203 (71%) had normal thallium uptake, 48 (17%) showed reversible thallium defects and 34 (12%) showed irreversible thallium defects. Of these 34 irreversible thallium defects, 19 (56%) were moderate and 15 (44%) were severe. Of the corresponding 285 segments, 200 (70%) had normal 99m Tc-MIBI uptake, while 37 (13%) showed moderate and 48 (17%) showed severe reduction of MIBI uptake. Myocardial segmental agreement for regional uptake score between initial thallium and resting 99m Tc-MIBI images was 90% (κ=0.78). Segmental agreement between delayed thallium and resting 99m Tc-MIBI images was 77% (κ=0.44). In particular, in 26 (9%) segments 99m Tc-MIBI uptake was severely reduced while delayed thallium uptake was normal or only moderately reduced. These data suggest that although rest-redistribution thallium and resting 99m Tc-MIBI cardiac imaging provide concordant results in the majority of myocardial segments, some segments with severely reduced resting 99m Tc-MIBI uptake may contain viable but hypoperfused myocardium. Thus, conclusions on myocardial viability based on 99m Tc-MIBI uptake should be made with caution in chronic coronary artery disease. (orig.)

  11. Technetium-99 in ''instant'' sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Mattsson, S.

    1978-01-01

    The 99 Tc-content in sup(99m)Tc-pertechnetate separated from 99 Mo by distillation or extraction has been studied with a plastic scintillation detector. The identification of the measured activity was achieved by beta-spectrometry, chemical separation and half-life studies. The frequency distribution of the sup(99)Tc/sup(99m)Tc-ratios in the different samples was observed to be log-normal. The most likely activity ratio was 0.4x10 -6 , the maximum value being 5x10 -6 . The specific activity of ''instant'' pertechnetate is approximately a factor of 60 lower than that normally recorded in pertechnetate derived from daily eluted column generators. The low specific activity of ''instant'' pertechnetate is primarily explained by the long time between separation and usage and secondly by the low yield of Tc in the distillation and extraction processes. In several of the ''instant'' pertechnetate solutions the carrier concentration exceeded the reductive capacity of the stannous ions in ''kits'' with small amounts of Sn(II) in usable form. (T.G.)

  12. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  13. Thrombolytic therapy for myocardial infarction: Assessment of efficacy by myocardial perfusion imaging with technetium-99m sestamibi

    International Nuclear Information System (INIS)

    Wackers, F.J.

    1990-01-01

    Technetium-99m (Tc-99m) sestamibi has been used to evaluate the efficacy of thrombolytic therapy. Improved image quality due to the higher photon energy of Tc-99m and the increased allowable doses of this radiopharmaceutical along with its lack of redistribution makes Tc-99m sestamibi an acceptable imaging agent for such studies. This imaging agent was used for serial quantitative planar and tomographic imaging to assess the initial risk area of infarction, its change over time and the relation to infarct-related artery patency in patients with a first acute myocardial infarction. Twenty-three of 30 patients were treated with recombinant tissue-type plasminogen activator (rt-PA) within 4 hours after onset of acute chest pain. Seven patients were treated in the conventional manner and did not receive thrombolytic therapy. The initial area at risk varied greatly both in patients treated with rt-PA and in those who received conventional therapy. Patients with successful thrombolysis and patient infarct arteries had a significantly greater reduction of Tc-99m sestamibi defect size than patients who had persistent coronary occlusion. Serial imaging with Tc-99m sestamibi could find important application in future clinical research evaluating the efficacy of new thrombolytic agents. Direct measurements of the amount of hypoperfused myocardium before and after thrombolysis could provide rapid and unequivocal results using fewer patients and avoiding the use of mortality as an end point. This approach has not yet been widely tested in the clinical arena

  14. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples....... This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...

  15. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  16. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  17. Dissemination of bacteria labeled with technetium-99m after laparotomy and abdominal insufflation with different CO2 pressures on rats

    International Nuclear Information System (INIS)

    Pitombo, Marcos Bettini; Faria, Clarice Abreu dos Santos Albuquerque de; Steinbruck, Klaus; Bernardo, Luciana Camargo; Bernardo Filho, Mario

    2008-01-01

    Purpose: To asses the dissemination of bacteria labeled with technetium-99m (99mTc) from peritoneal cavity after different surgical procedures. Methods: Bacteria of the Escherichia coli species labeled with 99mTc were used in a concentration of 108 units of colony-makers for ml (UFC/ml) and 1 ml was inoculated through intra-peritoneal via. Forty-eight rats were divided into four groups: control, laparotomy, pneumoperitoneum with 10 mmHg and pneumoperitoneum with 20 mmHg of CO2. Procedures were performed 20 min after injection of the inoculum and lasted 30 min. Animals were sacrificed after six hours (Group 1) and 24 hours (Group 2). Samples of blood, liver and spleen were collected for radioactivity counting. Results: After six hours, indirect detection of the bacteria in different organs was uniform in all groups. After 24 hours, a larger detection of technetium was observed in the livers of animals of the group insufflated with 20 mmHg of CO2, when compared with those of control group (p<0.01). The other groups did not present statistically significant variations. Conclusions: The use of a higher intra-abdominal pressure was associated with a higher bacterial dissemination to the liver. The application of lower intra-abdominal pressures may be associated with a lower dissemination of the infectious status during laparoscopic approach of peritonitis status. (author)

  18. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  19. Biodistribution Study of the Anaesthetic Sodium Phenobarbital Labelled with Technetium-99m in Swiss Mice Infected with Schistosoma mansoni Sambon, 1907

    Directory of Open Access Journals (Sweden)

    Susana Balmant Emerique Simões

    1997-09-01

    Full Text Available Technetium-99m (99mTc is a radionuclide that has negligible enviromnental impact, is easily available, inexpensive and can be used as a radioactive tracer in biological experiences. In order to know the mode of action of sodium phenobarbital in moving adult Schistosoma mansoni worms from mesenteric veins to the liver, we labelled sodium phenobarbital (PBBT with 99mTc and a biodistribution study in infected and non-infected Swiss mice was performed. The PBBT was incubated with stannous chloride used as reducing agent and with 99mTc, as sodium pertechnetate. The radioactivity labelling (% was determined by paper ascending chromatography perfomed with acetone (solvent. The 99mTc-PBBT was administered by intraperitoneal route to Swiss mice infected eight weeks before. The animals were perfused after diferent periods of time (0,1,2,3,4 hr when blood, spleen, liver, portal vein, mesenteric veins, stomach, kidneys and adult worms were isolated. The radioactivity present in these samples was counted in a well counter and the percentage was determined. The radioactivity was mainly taken up by the blood, kidney, liver and spleen. No radioactivity was found on the adult worms. We concluded that the worm shift was due to an action on the host of the sodium phenobarbital

  20. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid in healthy individuals

    Directory of Open Access Journals (Sweden)

    Isabella Martins de Albuquerque

    Full Text Available ABSTRACT Objective: To evaluate the effects of positive expiratory pressure (PEP on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females with a mean age of 28.3 ± 5.4 years, a mean FEV1/FVC ratio of 0.89 ± 0.14, and a mean FEV1 of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA radioaerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels-10 cmH2O (n = 10, 15 cmH2O (n = 10, and 20 cmH2O (n = 10. The 99mTc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of 99mTc-DTPA was significantly shorter when PEP was applied-at 10 cmH2O (p = 0.044, 15 cmH2O (p = 0.044, and 20 cmH2O (p = 0.004-in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects.

  1. Relative uptake of technetium 99m stannous colloid by neutrophils and monocytes is altered by gram-negative infection

    International Nuclear Information System (INIS)

    Ramsay, Stuart C.; Maggs, Jacqueline A.; Ketheesan, Natkunam; Norton, Robert; LaBrooy, Justin

    2005-01-01

    Gram-negative infection alters phagocytic cell function; hence, it could affect phagocytic uptake of inorganic colloids by these cells. Neutrophil and monocyte uptake of technetium 99m stannous colloid ( 99m Tc SnC) in whole blood was measured in 10 patients with gram-negative infection (Burkholderia pseudomallei) and 7 controls. Mean uptake per individual neutrophil was reduced in infection. Uptake per monocyte was not significantly different. Blood from six normal individuals was incubated with lysed B. pseudomallei and colloid, which showed reduced neutrophil uptake, but increased monocyte uptake. These results indicate that uptake of 99m Tc SnC stannous colloid can be used to measure alteration in phagocytic cell function. They suggest that infection with B. pseudomallei is associated with reduced phagocytosis by individual neutrophils, possibly through toxic effects of bacterial products. This could have immunopathogenic consequences for this gram-negative infection and may explain why it responds to granulocyte colony-stimulating factor

  2. Evaluation of Deoxyribonucleic Acid Toxicity Induced by the Radiopharmaceutical 99mTechnetium-Methylenediphosphonic Acid and by Stannous Chloride in Wistar Rats

    Directory of Open Access Journals (Sweden)

    Adriano Caldeira-de-Araujo

    2012-11-01

    Full Text Available Radiopharmaceuticals are employed in patient diagnostics and disease treatments. Concerning the diagnosis aspect, technetium-99m (99mTc is utilized to label radiopharmaceuticals for single photon computed emission tomography (SPECT due to its physical and chemical characteristics. 99mTc fixation on pharmaceuticals depends on a reducing agent, stannous chloride (SnCl2 being the most widely-utilized. The genotoxic, clastogenic and anegenic properties of the 99mTc-MDP(methylene diphosphonate used for bone SPECT and SnCl2 were evaluated in Wistar rat blood cells using the Comet assay and micronucleus test. The experimental approach was to endovenously administer NaCl 0.9% (negative control, cyclophosphamide 50 mg/kg b.w. (positive control, SnCl2 500 μg/mL or 99mTc-MDP to animals and blood samples taken immediately before the injection, 3, and 24 h after (in the Comet assay and 36 h after, for micronucleus test. The data showed that both SnCl2 and 99mTc-MDP-induced deoxyribonucleic acid (DNA strand breaks in rat total blood cells, suggesting genotoxic potential. The 99mTc-MDP was not able to induce a significant DNA strand breaks increase in in vivo assays. Taken together, the data presented here points to the formation of a complex between SnCl2 in the radiopharmaceutical 99mTc-MDP, responsible for the decrease in cell damage, compared to both isolated chemical agents. These findings are important for the practice of nuclear medicine.

  3. Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection

    Energy Technology Data Exchange (ETDEWEB)

    Devillers, A.; Moisan, A.; Garin, E.; Bourguet, P. [CRLCC Eugene Marquis, Service de Medecine Nucleaire, Rennes (France); Hennion, F.; Poirier, J.Y. [CHRU Pontchaillou, Service d`Endocrinologie, Rennes (France)

    1998-02-01

    We conducted a prospective study in order to evaluate the contribution of technetium-99m hexamethylpropylene amine oxime (HMPAO) labelled leucocyte scintigraphy to the diagnosis and follow-up of osteomyelitis in the diabetic foot. The study was conducted between October 1992 and November 1996 and included 42 patients (30 men and 12 women; mean age 63 years) with diabetes mellitus (type 1, n = 22, type 2, n = 20) who had a total of 56 diabetic foot ulcers. The initial exploration included standard radiography, three-phase bone scintigraphy and {sup 99m}Tc-HMPAO labelled leucocyte scintigraphy (HMPAO-LS), performed within a 3-day interval. For the 56 ulceration sites, 26 cases of osteomyelitis were diagnosed: ten on the basis of radiographic and histological/bacteriological criteria after bone biopsy, 11 after radiographic follow-up and five on the basis of biopsy results alone. No osteomyelitis was present at 30 sites, there were seven cases of cellulitis. The sensitivity and specificity of {sup 99m}Tc-HMPAO-LS were 88.4% and 96.6% respectively (23 true-positives, 29 true-negatives, one false-positive, three false-negatives). The accuracy of radiography, {sup 99m}Tc-methylene diphosphonate and HMPAO-LS was 69.6%, 62.5%, and 92.9%, respectively. Follow-up scintigraphy (n = 14) 4 months after initial diagnosis and 1 month after antibiotic withdrawal confirmed cure of osteomyelitis despite the absence of complete clinical regression of the ulcers. In conclusion, {sup 99m}Tc-HMPAO labelled leucocyte scintigraphy was found to be an excellent method for the diagnosis of osteomyelitis in the diabetic foot. It can contribute to follow-up, particularly when clinical regression of perforating ulcers is incomplete and cure of osteomyelitis must be confirmed in order that antibiotic treatment may be discontinued. (orig.) With 5 figs., 3 tabs., 28 refs.

  4. Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents

    Energy Technology Data Exchange (ETDEWEB)

    Bellande, Emmanuel; Comazzi, Veronique; Laine, Jacques; Lecayon, Michele; Pasqualini, Roberto; Duatti, Adriano; Hoffschir, Didier

    1995-04-01

    The symmetrical complexes [{sup 99m}Tc][TcN(R{sub 2}PS{sub 2}){sub 2}] [R = CH{sub 3}, CH{sub 2}CH{sub 3}, CH{sub 2}CH{sub 2}CH{sub 3}, CH{sub 2}(CH{sub 3}){sub 2}], and the unsymmetrical complex [{sup 99m}Tc][TcN(Me{sub 2}PS{sub 2})(Et{sub 2}PS{sub 2})] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R{sub 2}PS{sub 2}]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding {sup 99}Tc-analogs prepared, at macroscopic level, by reacting the complex [{sup 99}TcNCl{sub 4}] [n-Bu{sub 4}N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS{sub 2} group. In vitro studies showed that these radiopharmaceuticals are stable in solution and that their chemical identity was not altered after incubation with rat blood. Biodistribution studies have been carried out in rats and primates. The results demonstrate that these compounds are significantly retained into the brain of these animals for a prolonged time. Planar gamma camera images have been obtained in monkeys showing a good visualization of the cerebral region. However, the existence of persistent blood activity yields a brain/blood ratio lower than that observed with other {sup 99m}Tc-based brain perfusion imaging agents.

  5. Minimizing Molybdenum 99 contamination in Technetium 99m Pertechnetate from the elution of 99Mo/ 99m Tc Generator

    International Nuclear Information System (INIS)

    Zakaria Ibrahim; Zulkifli Hashim; Bohari Yaacob

    2011-01-01

    Radioisotope Tc-99m is widely used for variety of nuclear medicine diagnostic procedures. For many commercial applications, it is prepared in a portable type generator. Nuclear Malaysia has been producing a dry type alumina chromatographic column generator utilizing fission Mo-99. This injectable Tc-99m must meet the British Pharmacopeia [1] product specification prior to be apply on patient. This paper provides a method to minimize the up to acceptable level Mo-99 in the final product. Purposely made pertechnetate contaminated with Mo-99 and re-eluate by using old generator. Excellent removal of Mo-99 impurity was achieved and more than 80 % of Tc-99m total activity was recovered. (author)

  6. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.; Edreira, M.; Viaggi, M.; De Castiglia, S.G.

    2001-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr3Octreotide(TOC) peptides when labelling with 99m Tc by two methods: direct and indirect using S-benzoyl- mercaptoacetyl triglycine (MAG-3) and hydrazinonicotinamide (HYNIC) as chelating agents. RC-160 was labelled with 125I (30% labelling yield) in order to examine its receptor specificity and to study the biodistribution in normal animals. A total binding of 30% and a non specific binding lower than 10% was obtained. On the other hand, the RC-160 was labelled with 99m Tc by a direct method (70% labelling yield), using sodium ascorbate and dithionite in order to reduce the peptide and 99m Tc, respectively. The synthesis of RC-160 with S-benzoyl MAG-3 and TOC with HYNIC, for labelling with 99m Tc are also described. The conjugates were prepared on a small scale and labelled with the radionuclide using tricine as co-ligands for HYNIC conjugates. Chromatographic studies were performed using HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labelled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labelling with 99m Tc using tricine as co-ligand although higher stability should be found for ternary co-ligands compared to tricine. (author)

  7. Effects of different concentrations of Maytenus ilicifolia (Espinheira Santa) on labelling of red blood cells and blood proteins with Technetium-99m

    International Nuclear Information System (INIS)

    Oliveira, Joelma F.; Braga, Ana Cristina S.; Bezerra, Roberto Jose A.C.; Bernardo-Filho, Mario

    1999-01-01

    The use of natural products in all over the world has been increased in Brazil as well as in other countries. Maytenus ilicifolia is commonly used in popular medicine. The labeling of red blood cells (RBC) with technetium-99m ( 99m Tc) have been for many studies in nuclear medicine. This labeling procedure depends on a reducing agent and stannous chloride is normally used. Here, we investigate if the extract of Maytenus ilicifolia is capable to alter the labeling of RBC and blood proteins with 99m Tc. Blood samples were incubated with Maytenus ilicifolia. Stannous chloride solution and Tc-99m were. Blood was centrifuged and plasma (P) and blood cells (C) were isolated. Samples of P or C were precipitated with trichloroacetic acid, centrifuged and IF and IF were separated. The percentage of radioactivity (% ATI) in C, IF-P and IF-C was calculated. The %ATI in decreased in C from 93.6±2.3 to 29.0±2.7, on FI-P from 77.6±1.2 to 7.5 ±1.0 and on FI-C from 80.0±3.4 to 12.6±4.8. Once in RBC labeling procedure with 99m Tc depends on the presence of stannous (+2), the substances of the natural product could increase the valence of stannous (+2) to stannic (+4). This fact would decrease the labeling of blood elements with 99m Tc. (author)

  8. Blood cell labeling with technetium-99m, (2)

    International Nuclear Information System (INIS)

    Uchida, Tatsumi; Yoshida, Hiroshi; Matsuda, Shin; Kimura, Hideo; Miura, Nobuo

    1978-01-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from 51 Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 μCi of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by 51 Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by 51 Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume. (auth.)

  9. Stabilization of marked hexametazima with technetium 99-metastables (99mTc) with chloride of cobalt hexahidratado, for the labelling of leukocytes

    International Nuclear Information System (INIS)

    Oliva Palencia, Rosa Maria

    1996-01-01

    Presently study you work with hexametilpropilen amino oxima (HM-PAO), radiopharmaceuticals of labelling leucocytes marking it with technetium 99 recently acquired of the second elution of a generator of molybdenum technetium adding chloride of cobalt hexahidratado in different concentrations, as stabilizing agent in order to settling down if it prolongs the useful life of this expensive radiopharmaceuticals for but of minutes. For it one carries out the determination from the purity radiochemical to the 5,60,120 and 180 minutes after the labelled and the labelling of leukocytes is made with quality control of the cells after the labelling compared against a control

  10. Preparation and assessment of [{sup 99m}Tc]technetium aquacarbonyl complexes with 1,2-diaminoethane-N-substituted ligands for tumor detection; Preparo e avaliacao de complexos de [{sup 99m}Tc]tecnecio aquacarbonil com ligantes 1,2-diaminoetano-N-substituidos para deteccao de tumores

    Energy Technology Data Exchange (ETDEWEB)

    Radin, Adriano

    2010-07-01

    Over least 15 years the complex [[{sup 99m}Tc](H{sub 2}0){sub 3}(CO){sub 3}]{sup +} has been used as an intermediary to obtain technetium radiopharmaceuticals for applications in cardiology, neurology and oncology. Two important characteristics of this molecule are: the facility for obtaining that compound from aqueous solutions and the easiness of substituting H{sub 2}O molecules by atoms of other ligand molecules. In this project we prepared new complexes [[{sup 99m}Tc](CMN{sup S001-3})(H{sub 2}O)(CO){sub 3}]{sup +}, where (CMNS001) = N-[(4-methoxy) benzyl]-1,2-diaminoethane, (CMNS003) = N,N'-bis-[(4-methoxy)benzyl]-1,2-diaminoethane, and assessed the uptake of these complexes in murine melanoma cancer cell B16F10 and breast cells MCF-7 and MDA-MD-231, and compared with [[{sup 99m}](MIBI){sub 6}]{sup +} uptake. In vitro uptake for both new technetium complex reached values close to 5%, for all cell lines, whereas the [[{sup 99m}Tc](MIBI){sub 6}]{sup +} uptake was close to 1 %. The assessment of subcellular distribution showed high accumulation of the new complex in the membrane fraction, for MDAMB-231, while for B16F10 accumulation occurred both in membrane and cytoplasm; the concentration of [[{sup 99m}Tc](MIBI){sub 6}]{sup +} was mainly in the cytoplasm portion. Biodistribution study in mice allowed to observe the capture of up to 1.6% of the administered dose per gram of tumor tissue for the complex [[{sup 99m}Tc](CMNS001)(H{sub 2}O)(CO){sub 3}]{sup +}, whereas other organs such as heart, lung and muscle, showed uptake of about 5.6%, 6.4% and 2%, respectively. The complexes in this work showed a high rate of uptake in vitro, but was not reproduced in vivo model, which can be related to low concentration of the complexes inside the cells and reduced vascularity of tumor tissue, with lower intake of complex through the blood system. (author)

  11. Synthesis and in vitro/in vivo evaluation of novel mono- and trivalent technetium-99m labeled ghrelin peptide complexes as potential diagnostic radiopharmaceuticals

    International Nuclear Information System (INIS)

    Koźmiński, Przemysław; Gniazdowska, Ewa

    2015-01-01

    Introduction: Ghrelin is an endogenous hormone present in blood. It is released from the oxyntic cells (X/A-like cells) of the stomach and fundus and can exist in two forms: as an acylated and des-acylated ghrelin. Ghrelin is an endogenous ligand of the growth hormone receptor (growth hormone secretagogue receptor, GHS-R). Overexpression of GHS-R1a receptor was identified in cells of different types of tumors (e.g. pituitary adenoma, neuroendocrine tumors of the thyroid, lung, breast, gonads, prostate, stomach, colorectal, endocrine and non-endocrine pancreatic tumors). This fact suggests that gamma radionuclide labeled ghrelin peptide may be considered as a potential diagnostic radiopharmaceutical. Methods: Ghrelin peptide labeled with mono- and trivalent technetium-99m complexes, 99m Tc-Lys-GHR, has been prepared on the n.c.a. scale. The physicochemical (stability, charge, shape, lipophilicity) and biological (receptor affinity, biodistribution) properties of the conjugates have been studied relevant to use the conjugates as receptor-based diagnostic radiopharmaceuticals. Results: The obtained conjugates [ 99m Tc(CO) 3 L N,O (CN-Lys-GHR)] + , 99m Tc(CO) 3 L S,O (CN-Lys-GHR) and 99m Tc(NS 3 )(CN-Lys-GHR) show different shape, charge, lipophilicity and two of them, 99m Tc(CO) 3 L S,O (CN-Lys-GHR) and 99m Tc(NS 3 )(CN-Lys-GHR), high stability in neutral aqueous solutions, even in the presence of excess concentration of histidine/cysteine competitive standard ligands or human serum. The in vitro binding affinity of 99m Tc-Lys-GHR conjugates with respect to growth hormone secretagogue receptor (GHS-R1a) present on DU-145 cells was in the range of IC 50 from 45 to 54 nM. The conjugate 99m Tc(CO) 3 L S,O (CN-Lys-GHR) exhibited excretion route by the liver and kidney in comparable degree, while the more lipophilic conjugate 99m Tc(NS 3 )(CN-Lys-GHR)—mainly by the liver. Conclusions: Basing on the results concerning physicochemical and biochemical properties, the

  12. Early estimation of acute myocardial infarct size soon after coronary reperfusion using emission computed tomography with technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kambara, H.; Fudo, T.; Tamaki, S.; Nohara, R.; Takatsu, Y.; Hattori, R.; Tokunaga, S.; Kawai, C.

    1987-01-01

    Early appearance of positive findings on a technetium-99m pyrophosphate scan has been shown to be associated with the presence of a reperfused acute myocardial infarction (AMI). Early technetium-99m pyrophosphate imaging was performed by emission computed tomography to evaluate reperfusion and to test the feasibility of estimating infarct size soon after coronary reperfusion based on acute positive tomographic findings. Twenty-seven patients with transmural AMI who were treated with intracoronary urokinase infusion followed by percutaneous transluminal coronary angioplasty underwent pyrophosphate imaging 8.7 +/- 2.1 hours after the onset of AMI. None of the 8 patients in whom reperfusion was unsuccessful had acute positive findings. Of 19 patients in whom reperfusion was successful, 17 had acute positive findings (p less than 0.001). In these 17, tomographic infarct volumes were determined from reconstructed transaxial images. The threshold for areas of increased pyrophosphate uptake within the infarct was set at 60% of peak activity by the computerized edge-detection algorithm. The total number of pixels in all transaxial sections showing increased tracer uptake were added and multiplied by a size factor and 1.05 g/cm3 muscle to determine infarct volume. The correlations of tomographic infarct volumes with peak serum creatine kinase (CK) levels (r = 0.82) and with cumulative release of CK-MB isoenzyme (r = 0.89) were good. Moreover, the time to positive imaging was significantly shorter than that to peak CK level (8.5 +/- 2.3 vs 10.4 +/- 2.2 hours, p less than 0.005)

  13. Labeling cellular elements of blood with Technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1990-08-01

    The purpose of this proposal is to develop new technique of labeling platelets and white cells with Tc-99m radionuclide. The conditions of labeling canine platelets and white cells with the lipid-soluble Tc-99m HMPAO have been optimized. The function of labeled platelets were evaluated by the determination of platelet survival time and recovery and these values were compared with that of In-111 tropolone labeled platelets. We developed the bilateral femoral catheterization model for the evaluation of platelet-thrombosis on control and heparin-bonded catheters in dogs. We are evaluating platelet thrombosis in the hollow-fiber hemodialyzer with Tc-99m and In-111 labeled platelets. We have developed the flow-loop for in vitro studies and are using a pig model for quantitation of platelet-consumption during hemodialysis. We are currently evaluating the new technique of platelet and white cell-labeling with Tc-99m and testing them in animal models of thrombosis and infection (osteo-myelitis). We are also using the Tc-99m HMPAO labeled mixed white cells in the early diagnosis (3-hour post-injection) of acute and chronic infection in patients and comparing the results with that of IN-111 oxine labeled white cells.

  14. Thermal neutron cross section measurements for technetium-99

    International Nuclear Information System (INIS)

    Yates, M.A.; Schroeder, N.C.; Fowler, M.M.

    1993-01-01

    Technetium, because of its long half-like (213,000 years) and ability to migrate in the environment, is a primary contributor to the long-term radioactivity related risk associated with geologic nuclear waste disposal. One proposal for converting technetium to an environmentally benign element investigating transmutation with an accelerator-based system, (i.e., Accelerator Transmutation of Waste, ATW). Planning for efficient processing of technetium through the transmuter will require knowledge of the thermal neutron cross section for the 99 Tc (n,γ) 100 Tc reaction. The authors have recently remeasured this cross section. Weighed aliquots (19-205 μg) of a NIST traceable 99 Tc standard were irradiated for 30-150 sec using the pneumatic open-quotes rabbitclose quotes system of LANL's Omega West Reactor. The two gamma rays from the 15.7-sec half-life product were measured immediately after irradiation on a high-resolution Ge detector. Thermal fluxes were measured using gold foils and Cd wrapped gold foils. The observation cross section is 19 ± 1 b. This agrees well with the 1977 value but has half the uncertainty

  15. Post-traumatic avascular necrosis of the femoral head predicted by preoperative technetium-99m antimony-colloid scan: an experimental and clinical study

    International Nuclear Information System (INIS)

    Turner, J.H.

    1983-01-01

    Technetium-99m antimony colloid was used to visualize the bone marrow of the head of the femur within twenty-four hours after interruption of the blood supply by subcapital osteotomy and section of the ligamentum teres in thirteen rabbits and within twenty-four hours after a subcapital fracture in thirty patients. Of the rabbits, all showed loss of marrow radioactivity over the affected femoral head. Bone-imaging with technetium-99m methylene diphosphonate, in contrast, failed to demonstrate any abnormality in the avascular head of the femur for as long as forty-eight hours after osteotomy. This difference between the marrow scan and the bone scan was attributed to earlier loss of function in the marrow cells than in the osteocytes. The thirty patients who had a preoperative scan within twenty-four hours after sustaining a subcapital fracture were treated by internal fixation with a Richards screw and plate and were followed for as long as two years, or until the patient died or radiographs showed evidence of avascular necrosis. The preoperative technetium-99m antimony-colloid activity in the head of the fractured femur was normal in sixteen patients and absent in fourteen; two of the fourteen had no activity in either hip, which precluded assessment of the fractured hip in these patients. In fifteen of the sixteen hips, preservation of the uptake in the marrow of the head of the fractured femur preoperatively predicted normal healing. Late segmental collapse developed in the remaining hip. In eleven of the twelve patients who had loss of marrow activity in the femoral head preoperatively, avascular necrosis developed within two years

  16. Detectable perfusion changes in MAG3 studies

    International Nuclear Information System (INIS)

    Shuter, B.; Bernar, A.; Roach, P.

    1998-01-01

    Full text: The use of 120 MBq 99m Tc-MAG 3 instead of 600 MBq 99m Tc-DTPA in renal imaging has degraded the images obtained during the perfusion phase. An increase of the minimum detectable change (MDC) in blood flow (BF) would also be expected. In transplant patients, renal BF is an important factor in patient management and the MDC should be small to allow early detection of reduced perfusion. We determined the mean and coefficient of variation (CoV: standard deviation/mean) of three renal perfusion indices as a function of counts in the time-activity curves (TACs). Transplant patients were given a dose of about 300 MBq of 99m Tc-MAG3 and images acquired at 8 fps for 60s. TACs made up from 8, 4, 2 or I images per second allowed calculation of renal perfusion indices as if doses of 300, 150, 75 and 38 MBq had been administered. Perfusion indices based on area under the TACs up to the arterial peak (API), the maximum slopes of the TACs (SPI) and the maximum slope of renal TAC and height of arterial TAC (BPI) were calculated by our routine renal software package. As the administered dose decreased, the CoV rose for all indices, least for BPI and most for API. BPI CoV increased from ∼10% at 300 MBq to 20% at 75 MBq, but API CoV rose from 6% to 46%. Mean BPI was stable over the dose range, but mean API showed a systematic increase of about 50% over the 300 MBq result. We conclude that at 120 MBq the MDC (expressed as 2*CoV) in BF is 30-60%, whereas at 600 MBq it may be as low as 10%, allowing earlier confident detection of a change in BF. The BPI was the preferred perfusion index as its mean value changed little and it had the least CoV at lower activities. The data also imply that relative kidney perfusion in the one individual will be much less accurate with 120 MBq of MAG 3

  17. 99mTc-Labeled Cyclic RGD Peptides for Noninvasive Monitoring of Tumor Integrin αvβ3 Expression

    Directory of Open Access Journals (Sweden)

    Yang Zhou

    2011-09-01

    Full Text Available This report describes the biologic evaluations of [99mTc(HYNIC-3P-RGD2(tricine(TPPTS] (99mTc-3P-RGD2: 6-hydrazinonicotinyl; 3P-RGD2 = PEG4-E[PEG4-c(RGDfK]2; PEG4 = 15-amino-4,7,10,13-tetraoxapentadecanoic acid; and TPPTS = trisodium triphenylpho-sphine-3,3′,3“-trisulfonate, [99mTc(HYNIC-3G-RGD2(tricine(TPPTS] (99mTc-3G-RGD2: 3G-RGD2 = G3-E[G3-c(RGDfK]2 and G3 = Gly-Gly-Gly, and 99mTcO(MAG2−3G-RGD2 (MAG2 = mercaptoacetylglycylglycyl as radiotracers for noninvasive imaging of tumor integrin αvβ3 expression in five xenografted tumor-bearing models. Biodistribution and imaging studies were performed in athymic nude mice bearing U87MG, MDA-MB-435, A549, HT29, or PC-3 tumor xenografts. Immunochemistry was performed using the cultured primary tumor cells and xenografted tumor tissues. It was found that the radiotracer tumor uptake followed the trend U87MG > MDA-MB-435 ≈ HT29 ≈ A549 > PC-3. The total integrin β3 expression levels followed the general trend: U87MG > MDA-MB-435 ≈ A549~HT29 > PC-3. There is a linear relationship between the radiotracer injected dose per gram tumor uptake and the total integrin β3 expression levels. On the basis of these, it was concluded that radiotracer tumor uptake is contributed by integrin αVβ3 expressed on tumor cells and activated endothelial cells of the tumor neovasculature. 99mTc-3P-RGD2 has the capability to monitor integrin αvβ3 expression in a noninvasive fashion.

  18. Preclinical evaluation of 99mTc(CO)3-aspartic-N-monoacetic acid, 99mTc(CO)3(ASMA), a new renal radiotracer with pharmacokinetic properties comparable to 131I-OIH

    Science.gov (United States)

    Lipowska, Malgorzata; Klenc, Jeffrey; Marzilli, Luigi G.; Taylor, Andrew T.

    2014-01-01

    In an ongoing effort to develop a renal tracer with pharmacokinetic properties comparable to PAH and superior to those of both 99mTc-MAG3 and 131I-OIH, we evaluated a new renal tricarbonyl radiotracer based on the aspartic-N-monoacetic acid ligand, 99mTc(CO)3(ASMA). The ASMA ligand features two carboxyl groups and an amine function for the coordination of the {99mTc(CO)3}+ core as well as a dangling carboxylate to facilitate rapid renal clearance. Methods rac-ASMA and L-ASMA were labeled with a 99mTc-tricarbonyl precursor and radiochemical purity of the labeled products was determined by HPLC. Using 131I-OIH as an internal control, we evaluated biodistribution in normal rats with 99mTc(CO)3(ASMA) isomers and in rats with renal pedicle ligation with 99mTc(CO)3(rac-ASMA). Clearance studies were conducted in 4 additional rats. In vitro radiotracer stability was determined in PBS buffer pH 7.4 and in challenge studies with cysteine and histidine. 99mTc(CO)3(ASMA) metabolites in urine were analyzed by HPLC. Results Both 99mTc(CO)3(ASMA) preparations had > 99% radiochemical purity and were stable in PBS buffer pH 7.4 for 24 h. Challenge studies on both revealed no significant displacement of the ligand. In normal rats, % injected dose in urine at 10 and 60 min for both preparations averaged 103% and 106% that of 131I-OIH, respectively. The renal clearances of 99mTc(CO)3(rac-ASMA) and 131I-OIH were comparable (P = 0.48). The tracer was excreted unchanged in the urine, proving its in vivo stability. In pedicle-ligated rats, 99mTc(CO)3(rac-ASMA) had less excretion into the bowel (P ASMA) complexes have pharmacokinetic properties in rats comparable to or superior to those of 131I-OIH, and human studies are warranted for their further evaluation. PMID:22717977

  19. Technetium-99m sestamibi myocardial tomography based on dipyridamole echocardiography testing in hypertensive patients with chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Moroni, C. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Tavolaro, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Danieli, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Bossini, A. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Cassone, R. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Colella, A.C. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1997-07-01

    The aim of this study was to evaluate the diagnostic capability of technetium-99m sestamibi tomography based on dipyridamole echocardiography testing in hypertensives with chest pain, and to compare the scintigraphic results with those of coronary angiography, exercise electrocardiography and dipyridamole echocardiography. Forty subjects with mild to moderate hypertension, chest pain and no previous myocardial infarction were submitted to {sup 99m}Tc-sestamibi tomography (at rest and after high-dose dipyridamole echocardiography) and to exercise electrocardiography testing. At coronary angiography 22 patients (group A) had significant epicardial coronary artery disease ({>=}70% stenosis of at least one major vessel) and 18 normal main coronary vessels (group B). Dipyridamole {sup 99m}Tc-sestamibi imaging was positive in 21/22 patients of group A and in 5/18 of group B. Dipyridamole echocardiography was positive in 18/22 patients of group A and in 5/18 of group B. Exercise electrocardiography was positive in 15/22 patients of group A and in 11/18 of group B. Four out of five subjects in group B with positive results in all the tests showed a slow run-off of angiographic contrast medium, probably due to small-vessel disease. Significant epicardial coronary artery disease in hypertensives with chest pain is unlikely when dipyridamole {sup 99m}Tc-sestamibi tomography is negative. When scintigraphy is positive, either epicardial coronary artery disease or a small-vessel disease condition is possible. The association of scintigraphy with dipyridamole echocardiography testing allows the assessment of contractile function and myocardial perfusion by a single pharmacological stress. (orig./AJ). With 3 figs., 2 tabs.

  20. Importance of methodology on (99m)technetium dimercapto-succinic acid scintigraphic image quality: imaging pilot study for RIVUR (Randomized Intervention for Children With Vesicoureteral Reflux) multicenter investigation.

    Science.gov (United States)

    Ziessman, Harvey A; Majd, Massoud

    2009-07-01

    We reviewed our experience with (99m)technetium dimercapto-succinic acid scintigraphy obtained during an imaging pilot study for a multicenter investigation (Randomized Intervention for Children With Vesicoureteral Reflux) of the effectiveness of daily antimicrobial prophylaxis for preventing recurrent urinary tract infection and renal scarring. We analyzed imaging methodology and its relation to diagnostic image quality. (99m)Technetium dimercapto-succinic acid imaging guidelines were provided to participating sites. High-resolution planar imaging with parallel hole or pinhole collimation was required. Two core reviewers evaluated all submitted images. Analysis included appropriate views, presence or lack of patient motion, adequate magnification, sufficient counts and diagnostic image quality. Inter-reader agreement was evaluated. We evaluated 70, (99m)technetium dimercapto-succinic acid studies from 14 institutions. Variability was noted in methodology and image quality. Correlation (r value) between dose administered and patient age was 0.780. For parallel hole collimator imaging good correlation was noted between activity administered and counts (r = 0.800). For pinhole imaging the correlation was poor (r = 0.110). A total of 10 studies (17%) were rejected for quality issues of motion, kidney overlap, inadequate magnification, inadequate counts and poor quality images. The submitting institution was informed and provided with recommendations for improving quality, and resubmission of another study was required. Only 4 studies (6%) were judged differently by the 2 reviewers, and the differences were minor. Methodology and image quality for (99m)technetium dimercapto-succinic acid scintigraphy varied more than expected between institutions. The most common reason for poor image quality was inadequate count acquisition with insufficient attention to the tradeoff between administered dose, length of image acquisition, start time of imaging and resulting image

  1. Tc-99m-hexakis(t-butylisonitrile)-technetium(I) (Tc-99m-TBI)

    International Nuclear Information System (INIS)

    Angelberger, P.; Dudczak, R.; Jones, A.G.; Lister-James, J.; Wagner-Loffler, M.; Buchheit, O.; Fally, F.

    1986-01-01

    The potassium analog (Tl-201)/sup +/ is widely used in nuclear cardiology but has inferior scintigraphic (80 keV photons), dosimetric and economic properties as compared to Tc-99m. Therefore considerable efforts have been made to develop a Tc-compound that would accumulate in the myocardium in relation to regional blood flow. This study was aimed at optimizing the preparation of Tc-TBI with n.c.a. Tc-99m, analyze and purify the product with HPLC, verify biodistribution in mice and undertake a clinical evaluation

  2. Technetium-99m direct radiolabeling of monoclonal antibody ior egf/r3

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Alejo A. Morales; Crespo, Francisco Zayas; Gandolff, Gilda Nunez; Escobar, Normando Iznaga; Perez, Niuvis Perez; Hernandez, Juan C. Izquierdo

    1998-01-01

    Monoclonal antibodies (MAbs) are being widely used for imaging studies, coupled mainly with {sup 99m}Tc. The antibody ior egf/r3 is a MAb against human epidermal growth factor receptor (hEGF-r), and we have developed a method for optimum labeling of this MAb with {sup 99m}Tc. The reduction was performed with 2-mercaptoethanol (2-ME) at a molar ratio of 2000:1 (2-ME:MAb) and methylene diphosphonate as transchelant. The integrity of reduced MAb was checked by mean of native polyacrylamide gel electrophoresis (PAGE) and gel filtration chromatography on Superose 12 (purity >99%). Radio colloids remained lower than 2%, and the labeling efficiency was 98.5%. The number of sulfhydryl groups generated was quantified using Ellman's reagent and was found to be 6.65 {+-} 0.69 per antibody molecule. In vitro stability studies in several challenging conditions (DTPA, human serum albumin and human serum) were performed, and no significant loss in binding percentage was seen. Radio receptor assay was used to test immunoreactivity of the reduced MAb. Both labeled and unlabeled MAbs were able to compete for binding to the hEGF-r with radioiodinated EGF. Biodistribution studies in BALB/c mice are reported.

  3. Technetium-99m direct radiolabeling of monoclonal antibody ior egf/r3

    International Nuclear Information System (INIS)

    Morales, Alejo A. Morales; Crespo, Francisco Zayas; Gandolff, Gilda Nunez; Escobar, Normando Iznaga; Perez, Niuvis Perez; Hernandez, Juan C. Izquierdo

    1998-01-01

    Monoclonal antibodies (MAbs) are being widely used for imaging studies, coupled mainly with 99m Tc. The antibody ior egf/r3 is a MAb against human epidermal growth factor receptor (hEGF-r), and we have developed a method for optimum labeling of this MAb with 99m Tc. The reduction was performed with 2-mercaptoethanol (2-ME) at a molar ratio of 2000:1 (2-ME:MAb) and methylene diphosphonate as transchelant. The integrity of reduced MAb was checked by mean of native polyacrylamide gel electrophoresis (PAGE) and gel filtration chromatography on Superose 12 (purity >99%). Radio colloids remained lower than 2%, and the labeling efficiency was 98.5%. The number of sulfhydryl groups generated was quantified using Ellman's reagent and was found to be 6.65 ± 0.69 per antibody molecule. In vitro stability studies in several challenging conditions (DTPA, human serum albumin and human serum) were performed, and no significant loss in binding percentage was seen. Radio receptor assay was used to test immunoreactivity of the reduced MAb. Both labeled and unlabeled MAbs were able to compete for binding to the hEGF-r with radioiodinated EGF. Biodistribution studies in BALB/c mice are reported

  4. Scintigraphic study of gastrointestinal transit and disintegration sites of mesalazine tablets labelled with technetium 99m

    Energy Technology Data Exchange (ETDEWEB)

    Sciarretta, G.; Furno, A.; Mazzoni, M.; Ferrieri, A.; Malaguti, P. (Ospedale Maggiore, Bologna (Italy))

    1993-09-01

    Tablets of mesalazine covered with a pH-dependent coating, labelled by an original technique with technetium-99m, were administered to 12 patients, 9 with Crohn's disease, 3 of which recurrent, 1 with ulcerative colitis, and 2 with irritable bowel syndrome, with the aim of verifying in vivo the intestinal site of disintegration and how the contents spread throughout the intestine. In all cases the tablet was broken down in the distal ileum at extremely variable intervals, from 5 to 27 h, and the contents spread into the nearby loops and into the colon. The notable differences in the residence time of the whole tablet in the ileum can be explained by differences in adhesion the inflamed mucosa and by a lower pH in the part of the ileum affected by the disease. 7 refs., 2 figs., 1 tab.

  5. Scintigraphic study of gastrointestinal transit and disintegration sites of mesalazine tablets labelled with technetium 99m

    International Nuclear Information System (INIS)

    Sciarretta, G.; Furno, A.; Mazzoni, M.; Ferrieri, A.; Malaguti, P.

    1993-01-01

    Tablets of mesalazine covered with a pH-dependent coating, labelled by an original technique with technetium-99m, were administered to 12 patients, 9 with Crohn's disease, 3 of which recurrent, 1 with ulcerative colitis, and 2 with irritable bowel syndrome, with the aim of verifying in vivo the intestinal site of disintegration and how the contents spread throughout the intestine. In all cases the tablet was broken down in the distal ileum at extremely variable intervals, from 5 to 27 h, and the contents spread into the nearby loops and into the colon. The notable differences in the residence time of the whole tablet in the ileum can be explained by differences in adhesion the inflamed mucosa and by a lower pH in the part of the ileum affected by the disease. 7 refs., 2 figs., 1 tab

  6. Prognostic value of 99mTc-MAG3 renal scintigraphy for the one-year outcome after kidney transplantation

    International Nuclear Information System (INIS)

    Guignard, R.; Rossi, M.; Mariano-Goulart, D.; Barbotte, E.

    2009-01-01

    Because of the increasing use of marginal grafts, it remains a significant difference in terms of transplants half-life between living donor or cadaver donor. The main objective of this study was to assess the prognostic value of various isotopic parameters available on the same day than surgery for the one-year outcome after kidney transplantation. A retrospective study of 100 patients, who received a renal allograft at the University Hospital of Montpellier between 1999 and 2006, and who performed 99m Tc-MAG 3 renal scintigraphy within 72 h after transplantation, was performed. Measurement of various isotopic parameters was performed for angiographic and tubular phases, over three different regions of interest. According to judgment criteria, namely the success or not of transplantation after the first year, previously obtained results were statistically compared. The results of our study confirmed the importance of vascular parameters, especially the Kirchner index, with a good correlation with renal function one year after transplantation. As expected by the physiological models, a well-perfused graft had the most chances of short-term survival. Kirchner index has a negative predictive value of more than 90% for the one-year success after transplantation (V.P.P. = 75%). Parameters assessing more specifically nephronic functional reserve (such as tubular function slope or uptake on perfusion peaks report) are independent risk factors for the failure during the first three months. (authors)

  7. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Usefulness of L,L-ethylenedicysteine - 99mTc complex (EC-99mTc) for the kidney investigations

    International Nuclear Information System (INIS)

    Surma, M.J.; Wiewiora, J.; Kapuscinksi, J.; Liniecki, J.

    1992-01-01

    To assess the usefulness of own EC- 99m Tc complex for the kidney function examination, the renoscintigraphy with EC- 99m Tc and clearance determinations were performed. During renoscintigraphy the kidney images were of superb quality, with overlaying organs (liver, spleen) not visualized. Renograms showed typical shapes, their TMAX and T1/2 values being insignificantly different from the obtained with other radiopharmaceuticals, used in renoscintigraphy (MAG 3 , hippuran). Very strict correlations were found between values of EC- 99m Tc and OIH- 131 I clearances (r=0.91) and excretion rate constants (r=0.92) of both radiopharmaceuticals. The correlation enabled formulation of an equation by which ERPF could be established from EC- 99m Tc clearance: ERPF OIH =1.245 x Cl EC +51.52. On the basis of this equation a lower boundary of the normal EC- 99m Tc clearance was established; it amounts to 300 ml/min/1.73 m 2 . (author). 17 refs, 5 figs, 1 tab

  9. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    Science.gov (United States)

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  10. Synthesis of Tc-99m labeled 1,2,3-triazole-4-yl c-met binding peptide as a potential c-met receptor kinase positive tumor imaging agent.

    Science.gov (United States)

    Kim, Eun-Mi; Joung, Min-Hee; Lee, Chang-Moon; Jeong, Hwan-Jeong; Lim, Seok Tae; Sohn, Myung-Hee; Kim, Dong Wook

    2010-07-15

    The mesenchymal-epithelial transition factor (c-Met), which is related to tumor cell growth, angiogenesis and metastases, is known to be overexpressed in several tumor types. In this study, we synthesized technetium-99m labeled 1,2,3-triazole-4-yl c-Met binding peptide (cMBP) derivatives, prepared by solid phase peptide synthesis and the 'click-to-chelate' protocol for the introduction of tricarbonyl technetium-99m, as a potential c-Met receptor kinase positive tumor imaging agent, and evaluated their in vitro c-Met binding affinity, cellular uptake, and stability. The (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12, [(99m)Tc(CO)(3)]13, and [(99m)Tc(CO)(3)]14) were prepared in 85-90% radiochemical yields. The cold surrogate cMBP derivatives, [Re(CO)(3)]12, [Re(CO)(3)]13, and [Re(CO)(3)]14, were shown to have high binding affinities (0.13 microM, 0.06 microM, and 0.16 microM, respectively) to a purified cMet/Fc chimeric recombinant protein. In addition, the in vitro cellular uptake and inhibition studies demonstrated the high specific binding of these (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12-14) to c-Met receptor positive U87MG cells. 2010 Elsevier Ltd. All rights reserved.

  11. Role of technetium-99m planar bone scanning in the evaluation of low back pain

    International Nuclear Information System (INIS)

    Valdez, D.C.; Johnson, R.G.

    1994-01-01

    The records of 1018 patients with low back pain in a tertiary spine referral practice were reviewed. One hundred thirty-nine out of 1018 (13.6%) underwent technetium-99m planar bone scannings as part of their investigation. Seventy-three out of 139 scans (52%) showed increased uptake in some area, but only 27 out of 139 (19.4%) showed increased uptake specifically in the low back. Scans consistently yielded no findings with reference to the back when the prescan diagnosis was spinal stenosis, lumbar pain syndrome, herniated nucleus pulposus, or postlaminectomy syndrome. Some scans gave positive findings in patients with a diagnosis of degenerative disc disease, pseudoarthrosis, spondylolisthesis, fracture, infection, metabolic disorder, or tumor. Positive scans were generally obtained early after presentation (within 3 months) and negative scans obtained later (after 6 months), suggesting that clinical suspicion is still the main indication for early scanning. Planar bone scanning was helpful in both diagnosis and therapeutic decision-making in many conditions. (orig.)

  12. Technetium-99m sestamibi leg scintigraphy for non-invasive assessment of propionyl-l-carnitine induced changes in skeletal muscle metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Cittanti, C. [Department of Nuclear Medicine, University of Ferrara (Italy); Colamussi, P. [Department of Nuclear Medicine, University of Ferrara (Italy); Giganti, M. [Department of Nuclear Medicine, University of Ferrara (Italy); Orlandi, C. [MEDCO Research, Inc., North Carolina (United States); Uccelli, L. [Department of Nuclear Medicine, University of Ferrara (Italy); Manfrini, S. [Surgical Pathology Institute, University of Ferrara (Italy); Azzena, G. [Surgical Pathology Institute, University of Ferrara (Italy); Piffanelli, A. [Department of Nuclear Medicine, University of Ferrara (Italy)

    1997-07-01

    Carnitine derivatives, such as propionyl-l-carnitine (PLC), have been shown to improve walking distance in patients with obstructive peripheral artery disease (PAOD). The aim of this study was to ascertain whether technetium-99m sestamibi leg scintigraphy may be a useful tool in the evaluation of changes in skeletal muscle metabolism induced by chronic therapy with PLC. Twenty patients with clinical and instrumental evidence of PAOD were randomly assigned to a 3-month period of therapy with either PLC or placebo. Rest {sup 99m}Tc-sestamibi leg scintigraphy and echo-Doppler sonography were performed on all subjects immediately before and upon completion of the treatment period. At the end of the protocol the following results were observed in patients who underwent PLC administration: (a) a significant increase in both thigh and calf {sup 99m}Tc-sestamibi uptake, in comparison with baseline values (P<0.001); (b) the absence of statistically significant modifications of Doppler blood flow indices of the lower limbs. In conclusion, after chronic administration of PLC, a significant increment in skeletal muscle uptake of {sup 99m}Tc-sestamibi was demonstrated without any apparent change in regional blood flow. This fact, if proven in further studies, may suggest a role for this tracer as a non-invasive probe of tissue bioenergetics. (orig.). With 4 figs., 4 tabs.

  13. Diagnostic Value of Technetium-99m-Dimercaptosuccinic Acid Scintigraphy in Prediction of Vesicoureteral Reflux in Children with First-time Febrile Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    Fatemeh Ataei

    2017-11-01

    Full Text Available Background: Imaging modalities such as voiding cystourethrography (VCUG, direct radionuclide cystography (DRNC, and renal cortical scintigraphy (RCS with technetium-99m dimercaptosuccinic acid (Tc-99mDMSA, are helpful in detecting possible abnormalities of urinary tract such as vesicoureteral reflux (VUR. However, there are confounding data regarding the preference of these modalities. In the present study, we aimed to assess the role of Tc-99mDMSA scan in prediction of possible VUR and the subsequent need for VCUG or DRNC. Materials and Methods: Three hundred fifty seven children under 14 years old with first-time febrile urinary tract infection (UTI who were admitted between April 2004 and February 2017 were enrolled. Data regarding to VCUG or DRNC in order to evaluate the presence of possible VUR were recorded. Finally, accuracy of Tc-99mDMSA scans in prediction of VUR were assessed. Results: Analyses showed a sensitivity and specificity of 95.65% and 14.72%, respectively for Tc-99mDMSA scan in detection of VUR. Patients with mild renal involvement in Tc-99mDMSA scans had a 3.5-fold greater risk of having VUR than those with a normal scans (odds ratio=3.5; 95% confidence interval [CI]: 1.4-8.58; p=0.007. In addition, the risk of VUR is up to 7.0-fold greater in children with moderate renal involvement (odds ratio=7.0; 95% CI: 2.6-13.2; p

  14. Labeling of thymidine analog with an organometallic complex of technetium-99m for diagnostic of cancer: radiochemical and biological evaluation

    International Nuclear Information System (INIS)

    Santos, Rodrigo Luis Silva Ribeiro

    2007-01-01

    Thymidine analogs have been labeled with different radioisotopes due to their potential in monitoring the uncontrollable cell proliferation. Considering that the radioisotopes technetium-99m still keep a privileged position as a marker due to its chemical and nuclear properties, this dissertation was constituted by the developed of a new technique of labeling of thymidine analog with 99m Tc, by means of the organometallic complex. The aims of this research were: synthesis of the organometallic complex technetium-99m-carbonyl, thymidine labeling with this precursor, evaluation of stability, and radiochemical e biological evaluation with healthy and tumor-bearing animals. The preparation of the organometallic precursor, using the CO gas, was easily achieved, as well as the labeling of thymidine with this precursor, resulting itself a radiochemical pureness of ≥ 97% and ≥ 94%, respectively. Chromatography systems with good levels of trustworthiness were used, ensuring the qualification and quantification of the radiochemical samples. The result of in vitro testing of lipophilicity disclosed that the radiolabeled complex is hydrophilic, with a partition coefficient (log P) of -1.48. The precursor complex and the radiolabeled have good radiochemical stability up to 6 h in room temperature. The cysteine and histidine challenge indicated losses between 8 and 1 1 % for concentrations until 300 mM. The biodistribution assay in healthy mice revealed rapid blood clearance and low uptake by general organs with renal and hepatobiliary excretion. The tumor concentration was low with values of 0.28 and 0.18 %ID/g for lung and breast cancer, respectively. The results imply more studies in other tumor models or the modification of the structure of the organic molecule that act like ligand. (author)

  15. Contribution of technetium-99m hexamethylpropylene amine oxime labelled leucocyte scintigraphy to the diagnosis of diabetic foot infection

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Garin, E.; Bourguet, P.; Hennion, F.; Poirier, J.Y.

    1998-01-01

    We conducted a prospective study in order to evaluate the contribution of technetium-99m hexamethylpropylene amine oxime (HMPAO) labelled leucocyte scintigraphy to the diagnosis and follow-up of osteomyelitis in the diabetic foot. The study was conducted between October 1992 and November 1996 and included 42 patients (30 men and 12 women; mean age 63 years) with diabetes mellitus (type 1, n = 22, type 2, n = 20) who had a total of 56 diabetic foot ulcers. The initial exploration included standard radiography, three-phase bone scintigraphy and 99m Tc-HMPAO labelled leucocyte scintigraphy (HMPAO-LS), performed within a 3-day interval. For the 56 ulceration sites, 26 cases of osteomyelitis were diagnosed: ten on the basis of radiographic and histological/bacteriological criteria after bone biopsy, 11 after radiographic follow-up and five on the basis of biopsy results alone. No osteomyelitis was present at 30 sites, there were seven cases of cellulitis. The sensitivity and specificity of 99m Tc-HMPAO-LS were 88.4% and 96.6% respectively (23 true-positives, 29 true-negatives, one false-positive, three false-negatives). The accuracy of radiography, 99m Tc-methylene diphosphonate and HMPAO-LS was 69.6%, 62.5%, and 92.9%, respectively. Follow-up scintigraphy (n = 14) 4 months after initial diagnosis and 1 month after antibiotic withdrawal confirmed cure of osteomyelitis despite the absence of complete clinical regression of the ulcers. In conclusion, 99m Tc-HMPAO labelled leucocyte scintigraphy was found to be an excellent method for the diagnosis of osteomyelitis in the diabetic foot. It can contribute to follow-up, particularly when clinical regression of perforating ulcers is incomplete and cure of osteomyelitis must be confirmed in order that antibiotic treatment may be discontinued. (orig.)

  16. Evaluation of technetium-99m exametazime stabilised with cobalt chloride as a blood flow tracer in focal cerebral ischaemia

    Energy Technology Data Exchange (ETDEWEB)

    Gartshore, G [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); Bannan, P [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); Patterson, J [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); Higley, B [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom); McCulloch, J [Wellcome Surgical Inst. and Hugh Fraser Neuroscience Labs., Glasgow Univ. (United Kingdom)

    1994-09-01

    A protocol has been devised to effectively extend the limited post-reconstitution shelf life of technetium-99m exametazime as a radiopharmaceutical for imaging cerebral blood flow (CBF) distribution. The potential of [sup 99m]Tc-exametazime stabilised with cobalt chloride for imaging CBF distribution as late as 4 h after reconstitution has been examined in ischaemic and non-ischaemic tissue in halothane-anaesthetised cats. Focal cerebral ischaemia was produced by permanent middle cerebral artery occlusion. The relationship between [sup 99m]Tc-exametazime uptake and retention and CBF (assessed with [[sup 14]C]iodoantipyrine 10 min after first radiopharmaceutical administration) was determined in the same tissue section with double label autoradiography. Over the CBF range 0 - 80 ml 100 g[sup -1] min[sup -1], the uptake of [sup 99m]Tc-exametazime (quantitatively and topographically) was linearly related to CBF irrespective of whether the [sup 99m]Tc-labelled tracer was unstabilised (and administered within 10 min of reconstitution) or was stabilised with cobalt chloride (and administered up to 240 min after reconstitution). For levels of CBF in excess of 80 ml 100 g[sup -1] min[sup -1] the excellent topographical relationship between [sup 99m]Tc-exametazime distribution and CBF is maintained but quantitatively, [sup 99m]Tc-exametazime underestimates CBF to a similar degree in animals receiving stabilised and unstabilised [sup 99m]Tc-exametazime. The presence of the stabiliser, cobalt chloride, extends greatly the period over which [sup 99m]Tc-exametazime can be used after reconstitution to generate images of CBF distribution in normal and ischaemic cerebral tissue. (orig.)

  17. Technetium-99m DTPA inhalation scintigraphy in patients treated with fluoxetine and maprotiline: preliminary results

    International Nuclear Information System (INIS)

    Kaya, G.C.; Durak, H.; Oezdogan, Oe.; Sayit, E.; Degirmenci, B.; Derebek, E.

    2000-01-01

    Drug-metabolising enzymatic activities have been detected in tracheobronchiolar, bronchiolar and alveolar regions in the lungs. Induction of phospholipidosis by amine drugs such as clorphentermine has also been shown. This study aimed to investigate the effect of fluoxetine and maprotiline, which contain amine groups in their structure, on pulmonary epithelial membrane permeability. Twenty-seven patients (mean age 36±12 years) with various psychiatric problems, of whom 17 were treated with fluoxetine and 10 with maprotiline, were included in this study. Technetium-99m diethylene triamine penta-acetic acid (DTPA) aerosol inhalation scintigraphy was performed before and after 4-6 weeks of therapy. Following the inhalation of 1480 MBq 99m Tc-DTPA for 3 min, lung images in a 64 x 64 matrix were obtained every minute for 30 min. Regions of interest were drawn around the periphery of the lungs and on the major airways. Clearance half-times (T 1/2 ) were calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was calculated on the first-minute image. There was no difference between the clearance rates of 99m Tc-DTPA before and after therapy for either the fluoxetine or the maprotiline group. After therapy, a significant decrease in PI was found in patients treated with fluoxetine (PI values before and after therapy: 0.53±0.03 and 0.49±0.05 respectively, P≤0.05). This finding might have been due to the induction of increased synaptic serotonin (5-HT) by fluoxetine, which acts by inhibiting the re-uptake of 5-HT on presynaptic membranes. Bronchoconstriction of small and medium airways may be caused by direct and indirect effects of 5-HT on smooth muscle contraction. (orig.)

  18. Technetium-99m DTPA inhalation scintigraphy in patients treated with fluoxetine and maprotiline: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, G.C.; Durak, H.; Oezdogan, Oe.; Sayit, E.; Degirmenci, B.; Derebek, E. [Dokuz Eyluel Univ., Izmir (Turkey). School of Medicine; Yemez, B.; Turhal, Ue. [Dept. of Psychiatry, Dokuz Eylul Univ. School of Medicine, Izmir (Turkey)

    2000-09-01

    Drug-metabolising enzymatic activities have been detected in tracheobronchiolar, bronchiolar and alveolar regions in the lungs. Induction of phospholipidosis by amine drugs such as clorphentermine has also been shown. This study aimed to investigate the effect of fluoxetine and maprotiline, which contain amine groups in their structure, on pulmonary epithelial membrane permeability. Twenty-seven patients (mean age 36{+-}12 years) with various psychiatric problems, of whom 17 were treated with fluoxetine and 10 with maprotiline, were included in this study. Technetium-99m diethylene triamine penta-acetic acid (DTPA) aerosol inhalation scintigraphy was performed before and after 4-6 weeks of therapy. Following the inhalation of 1480 MBq {sup 99m}Tc-DTPA for 3 min, lung images in a 64 x 64 matrix were obtained every minute for 30 min. Regions of interest were drawn around the periphery of the lungs and on the major airways. Clearance half-times (T{sub 1/2}) were calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was calculated on the first-minute image. There was no difference between the clearance rates of {sup 99m}Tc-DTPA before and after therapy for either the fluoxetine or the maprotiline group. After therapy, a significant decrease in PI was found in patients treated with fluoxetine (PI values before and after therapy: 0.53{+-}0.03 and 0.49{+-}0.05 respectively, P{<=}0.05). This finding might have been due to the induction of increased synaptic serotonin (5-HT) by fluoxetine, which acts by inhibiting the re-uptake of 5-HT on presynaptic membranes. Bronchoconstriction of small and medium airways may be caused by direct and indirect effects of 5-HT on smooth muscle contraction. (orig.)

  19. Renal excretion of /sup 99m/Tc-diphosphonate in osteomalacia

    International Nuclear Information System (INIS)

    Macfarlane, J.D.; Khairi, M.R.A.; Ricciardone, M.; Wellman, H.N.; Johnston, C.C. Jr.

    1979-01-01

    Bone scans were performed on a patient with osteomalacia using /sup 99m/technetium-ethane-1-hydroxy-1,1-diphosphonate (/sup 99m/Tc-EHDP). The renal excretion of /sup 99m/Tc-EHDP was measured and the results were compared with those obtained in 4 patients with idiopathic osteoporosis

  20. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, Esteban R.; Crudo, Jose L.; Edreira, Martin M.; Castiglia, Silvia G.

    1999-01-01

    Biological and radiochemical studies have been carried out on two labelled somatostatin analogues, the peptide RC-150 and the Tyr 3 -Octreotide. Both analogues have been labelled with 99m Tc using the direct and the indirect method and MAG-3 and HYNIC as chelating agents. By the direct method RC-150 was labelled using sodium ascorbate and dithionite as reducing agents. The radiochemical purity was 70%. By the indirect method, in the case of RC-160 with MAG-3 a radiochemical purity higher than 70% was attained while a purity of 100% was reached in the case of Tyr 3 -Octreotide with HYNIC. The biological distribution of HYNIC-Tyr 3 -Octreotide has been studied in rats. (author)

  1. Technetium compounds; Compuestos de tecnecio

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, C.A. de [Instituto Nacional de Ciencias Medicas y Nutricion Salvador Zubiran, Vasco de Quiroga 15, 14000 Tlalpan D.F. (Mexico); Ferro F, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The first radiopharmaceuticals of {sup 99m} Tc, also call of 'first generation' as colloids, aggregates and simple complexes were developed with relative easiness without it was necessary a wide understanding of its chemical structure. In the radiopharmaceuticals of 'second generation' were included those derived of the HIDA for hepatobiliary images, MAG3 and EC for images of tubular renal de purification, HMPAO and ECD for images of cerebral perfusion and MIBI and tetrofosmin for images of heart perfusion, that which implies a bigger demand in terms of the chemical knowledge. At the moment, we can affirm that the future of the radiopharmaceuticals of {sup 99m} Tc is based on the use of small and relevant biomolecules with high biological activity that allow the visualization in vivo of specific receiving sites and/or its expression in diverse pathologies. It is for it that with the 'third generation' is necessary a wide one knowledge of the chemistry of the technetium that allows the design and characterization of highly specific bio complexes. In this book, although focused mainly to the chemistry of the Tc, a brief revision is also presented on the main biologically active molecules that, coordinated the {sup 99m} Tc, present a high recognition In vivo for specific receivers. (Author)

  2. Successful application of technetium-99m-labeled octreotide acetate scintigraphy in the detection of ectopic adrenocorticotropin-producing bronchial carcinoid lung tumor: a case report

    Directory of Open Access Journals (Sweden)

    Fallahi Babak

    2010-10-01

    Full Text Available Abstract Introduction The diagnostic efficacy of somatostatin receptor scintigraphy labeling with 111 indium in the localization of tumors has been assessed in a limited number of patients with contradictory outcomes. Here, we describe the case of a patient with an ectopic adrenocorticotropic hormone-producing bronchial carcinoid tumor diagnosed preoperatively using technetium-99m-labeled octreotide acetate scintigraphy. Case presentation A 29-year-old Asian man presented to our hospital with the typical clinical features of Cushing's syndrome, which he had had for a duration of 18 months. The results of a biochemical evaluation revealed he had adrenocorticotropic hormone-dependent Cushing's syndrome. The results of a spiral abdominal computed tomography scan showed he had bilateral adrenal hypertrophy. A magnetic resonance image of the patient's brain showed he had a normal hypophysis. Whole body technetium-99m-labeled octreotide acetate scintigraphy was performed to check for the presence of an ectopic adrenocorticotropic hormone-producing tumor. The scan results showed a small focal increase in uptake in the lower lobe of our patient's right lung, just above his diaphragm. A spiral chest computed tomography scan also revealed a small non-specific lesion in the same region. A transthoracic biopsy was then performed. Pathological evaluation confirmed the diagnosis of a carcinoid tumor, of the adrenocorticotropic hormone-producing type. After surgical removal, the patient's symptoms resolved and significant clinical improvement was achieved. Conclusions This case report shows that technetium-99m-labeled octreotide acetate scintigraphy can effectively detect an ectopic adrenocorticotropic hormone-producing bronchial carcinoid.

  3. Tc99m MDP kits, production and quality control

    International Nuclear Information System (INIS)

    Othman, I.; Yassine, T.; Lababidi, Z.; Kouli, M.

    1992-11-01

    MDP kits for labelling with Tc 99m were locally produced in different conditions, and the conditions for preparation were optimized. The quality control studies showed that the prepared kits were very good quality and comparable with that imported. Radiochemical purities ranged between 95-98% while reduced technetium ranged between 2-3% and free pertechnetate did not exceed 1%. Bioscan and biodistribution studies also showed high localization of Tc 99m in the skeleton of rats and rabbits. (author). 8 refs., 14 tabs

  4. Diuretic renography in hydronephrosis: renal tissue tracer transit predicts functional course and thereby need for surgery.

    Science.gov (United States)

    Schlotmann, Andreas; Clorius, John H; Clorius, Sandra N

    2009-10-01

    The recognition of those hydronephrotic kidneys which require therapy to preserve renal function remains difficult. We retrospectively compared the 'tissue tracer transit' (TTT) of (99m)Tc-mercaptoacetyltriglycine ((99m)Tc-MAG(3)) with 'response to furosemide stimulation' (RFS) and with 'single kidney function timely TTT maintained function. Without surgery 0 of 9 kidneys with timely TTT but obstructive RFS and only 1 of 16 kidneys with timely TTT but SKF timely TTT may exclude risk even in the presence of an obstructive RFS or SKF < 40%.

  5. Primary breast cancer imaging with technetium-99m sestamibi and its relation with P-glycoprotein overexpression

    Energy Technology Data Exchange (ETDEWEB)

    Moretti, J.L. [Medicine Nucleaire, CHU Bobigny, Paris (France); Azaloux, H. [Medicine Nucleaire Oncologie, Hopital P. Zobda Quitman, Fort de France (France); Boisseron, D. [Medicine Nucleaire Oncologie, Hopital P. Zobda Quitman, Fort de France (France); Kouyoumdjian, J.C. [Service de Biochemie, Hopital Henri Mondor, Creteil (France); Vilcoq, J. [Service de Cancerologie-Radiotherapie, Inst. Curie, Paris (France)

    1996-08-01

    The aim of this preliminary study was to evaluate retrospectively sestamibi scintigraphy in relation to the presence of the 170-kDa P-glycoprotein (Pgp), which represents an expression of multidrug resistance in patients with primary breast cancer. Fifteen women (age range 37-76 years) were referred for technetium-99m sestamibi scintigraphy because of suspicious breast lesions detected by mammography and ultrasonography, and subsequently assessed by fine-needle aspiration. Scintigraphy was performed 30 min following the injection of 500 MBq {sup 99m}Tc-sestamibi. Three planar anterior and oblique images were obtained with the patient in the supine position. Excised tumours were assessed for cytosolic CA 15.3, oestrogen (OR) and progesterone (PR) receptors and c-erb B2 neu oncogene. Pathology revealed that only 13 of the 15 patients had malignant tumours. The two benign tumours were sestamibi-negative and Pgp-positive. Sestamibi scintigraphy was positive in 10 of the 13 malignant lesions (including nine of ten infiltrating ductal carcinomas). Two of the three lesions with false-negative scintigraphy were Pgp-negative; in one of these cases histology revealed an invasive lobular carcinoma and in the other, mucinous adenocarcinoma. The third false-negative lesion was a Pgp-positive infiltrating ductal carcinoma which was c-erb B2 neu-negative but CA 15.3-, OR- and PR-positive. This preliminary study confirms that the resistance to chemotherapy which may occur in patients with primary breast cancer can be a cause of negative sestamibi scintigraphy. (orig.)

  6. A comparative technetium 99m hexamethylpropylene amine oxime SPET study in different types of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Habert, M O; Piketty, M L; Askienazy, S [Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Medecine Nucleaire; Spampinato, U; Mas, J L; Recondo, J de; Rondot, P [Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Neurologie; Bourdel, M C [Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Psychiatrie

    1991-01-01

    Regional cerebral perfusion was evaluated by single photon emission tomography (SPET) using technetium 99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) as a tracer, in 13 control subjects and 44 age-matched patients suffering from dementia of the Alzheimer's type (DAT, n=19) presumed Pick's disease (n=5), idiopathic Parkinson's disease with dementia (DPD, n=15) and progressive supranuclear palsy (PSP, n=5), HMPAO uptake was measured in the superior frontal, inferior frontal, parietal, temporal and occipital cortices, and the perfusion values were expressed as cortical/cerebellar activity ratios. As compared with controls, tracer uptake ratios in the DAT group were signficantly reduced over all cortical regions, with the largest defects in the parieto-temporal and superior frontal cortices. A marked hypoperfusion affecting the superior and inferior frontal cortices was found in Pick's diesease, whereas a mild but significant hypoperfusion was observed only in the superior frontal cortex of patients with PSP. In the DPD group, HMPAO uptake was significantly reduced in the parietal, temporal and occipital cortices, but not in the frontal cortex. These results show that DAT and DPD share the opposite anteroposterior HMPAO uptake defect as compared with the Pick's and PSP groups. (orig.).

  7. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-{sup 99m}-labeled diethylenetriaminepentaacetic acid in healthy individuals

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, Isabella Martins de, E-mail: albuisa@gmail.com [Universidade Federal de Santa Maria (UFSM), Santa Maria, RS (Brazil). Departamento de Fisioterapia e Reabilitacao; Cardoso, Dannuey Machado; Paiva, Dulciane Nunes [Universidade de Santa Cruz do Sul, RS (Brazil); Masiero, Paulo Ricardo; Menna-Barreto, Sergio Saldanha [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre (Brazil); Resqueti, Vanessa Regiane; Fregonezi, Guilherme Augusto de Freitas [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)

    2016-11-15

    Objective: To evaluate the effects of positive expiratory pressure (PEP) on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females) with a mean age of 28.3 ± 5.4 years, a mean FEV{sub 1}/FVC ratio of 0.89 ± 0.14, and a mean FEV{sub 1} of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m labeled diethylenetriaminepentaacetic acid ({sup 99m}TcDTPA) radio aerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels—10 cmH{sub 2}O (n = 10), 15 cmH{sub 2}O (n = 10), and 20 cmH{sub 2}O (n = 10). The {sup 99m}Tc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of {sup 99m}Tc-DTPA was significantly shorter when PEP was applied—at 10 cmH{sub 2}O (p = 0.044), 15 cmH{sub 2}O (p = 0.044), and 20 cmH{sub 2}O (p = 0.004) - in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects. (author)

  8. Quantification of ionic-channel abnormalities in cancer cells using 99mTc-diisopropyliminodiacetic acid (DISIDA)

    International Nuclear Information System (INIS)

    Yoon, Eun Jeong; Jang, Yoo Jueng; Kim, Nae Hyun; Kim, Meyoung Kon

    2001-01-01

    Ion channels and intracellular concentration of Ca 2+ or K + are thought to be involved in cell proliferation and tumor development. To measure the ionic-channel abnormalities in a quantitative manner, we used ionic-channel gated hepatobiliary imaging agents such as 99m Tc-DISIDA and 99m Tc-MAG3-biocytin. For in vivo study, dynamic images showed that 99m Tc-DISIDA coinjected with bilirubin had a higher blood background and a lower hepatic uptake than 99m Tc-DISIDA alone, whereas 99m Tc-MAG3-biocytin did not affected by bilirubin coinjection. For in vitro study, the cellular uptake of 5 different types of human cancer cells were ranked as follows: SK Mel-1 (melanoma), MCF-7 (breast adenocarcinoma), Jurkat (T-cell leukemia), SK-Mel-2 (melanoma), and HL-60 (polymyelocytic leukemia). In summary, these results demonstrated that the combination of 99m Tc-DISIDA and SK-Mel-1 is the most appropriate system for evaluation in ionic-channel abnormalities of cancer cells

  9. Studies on quality control of technetium-99m labelling kits

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Park, Kyung Bae; Awh, Ok Doo

    1987-12-01

    Various experiments for the quality control of Tc-99m labelled radiopharmaceuticals such as Tc-99m-phytate, Tc-99m-MDP, Tc-99m-Tin Colloid, Tc-99m-DISIDA, Tc-99m-DTPA,Tc-99m-DMSA, Tc-99m-Gulcoheptonate, TC-99m-Pyrophosphate, Tc-99m-HSA, and Tc-99m-HAM were carried out. Labelling yield and radiochemical purity of each of the instant labelling kit of KAERI made were determined by means of radiochromatography. Biodistribution in mice and whole body or specific organ imagings of rabbits were also carried out and discussed the relationship between the data of biodistributions and radiochemical purities. Labelling yeilds were above 98% for almost all of the labelling kits. The radio-pharmaceuticals were accumulated at each target organ with moderate specifities. In case of radiochemical purity of above 98%, the biodistribution and gamma imagings were also better. The kits of MDP and DISIDA were stable at least for four moths while the other kits at least eight months. (Author)

  10. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  11. Scintigraphic study of palpable breast nodes with {sup 99m} Tc-tetrofosmin; Estudo cintilografico de nodulos palpaveis da mama com {sup 99m} Tc - tetrofosmin

    Energy Technology Data Exchange (ETDEWEB)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia; Amarante Junior, Jose Luiz de Medeiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear; Fabricio, Maria Ines Menescal [Universidade Federal, Rio de Janeiro, RJ (Brazil). Inst. de Ginecologia

    1998-12-01

    In Brazil, breast carcinoma has the greater incidence among women. In 1996, about 31,210 new cases were diagnosed. The purpose of this study is to determine if {sup 99m} technetium-tetrofosmin preferentially concentrates within malignant palpable breast nodes, distinguishing them from the benign lumps. Fifth-four consecutive and unsolicited women, mean age 47.5 +- 10.7 years, with palpable nodes in breast, underwent breast scintigraphy with {sup 99m} technetium-tetrofosmin and excisional biopsy or fine needle puncture within interval eight weeks. Histopathologic studies demonstrated 13 cysts, 1 cyst with local inflammation, 11 fibroadenoma, 2 fibrodysplasias, 3 fibroadenomas with high cellularity, 1 fibrocystic change with local inflammation, 23 invasive intraductal carcinomas and 1 invasive lobular carcinoma. The nodes ranged from 10 to 100 mm in greater diameter. The scintigraphic study yielded 30 true-negative cases, 24 true-positives, no false-negative and 1 false-positive. This case was a fibrocystic lump with local inflammation. Two patients had metastases in axillary lymph nodes, well detected in scintigraphy. The statistic analysis showed: sensitivity, 100%; specificity, 96.8%; accuracy, 98.2%; negative predictive value, 100%; positive predictive value, 96.0%. Nonparametric tests of Fisher and Chi-square rejected the antithesis at a confidence interval of 99.9% (p < 0.001). We concluded that {sup 99m} technetium-tetrofosmin preferentially concentrates in malignant palpable breast nodes and can help to distinguish them from the benign tumors with with very high accuracy. (author)

  12. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  13. Prediction of remission in Graves` disease treated with long-term carbimazole therapy: evaluation of technetium-99m thyroid uptake and TSH concentrations as prognostic indicators

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, R. [Dept. of Nuclear Medicine, Batra Hospital, New Delhi (India)

    1996-02-01

    Computerized technetium-99m thyroid uptake and thyrotropin (TSH) estimation using a sensitive immunoradiometric assay were performed at presentation and following completion of an 18-month course of antithyroid drug therapy in 45 patients with Graves` disease. All patients had increased {sup 99m}Tc thyroid uptake and subnormal TSH levels before the start of treatment. Twentytwo patients developed recurrent hyperthyroidism in a 3-year follow-up period. Of the 22 patients with relapse, 20 had had a persistently increased {sup 99m}Tc thyroid uptake at the end of the course of carbimazole treatment, whereas TSH had remained subnormal in 18 of the 22. All 23 patients who remained in remission until the end of the 3-year follow-up had had normal {sup 99m}Tc thyroid uptake following completion of antihyroid drug treatment. TSH levels had reverted to normal in 19 cases, but remained subnormal in four cases in this group at the end of treatment. The results suggest a high likelihood of relapse in patients who have persistently increased {sup 99m}Tc thyroid uptake and subnormal TSH after a full course of carbimazole treatment. Patients whose {sup 99m}Tc thyroid uptake and TSH levels have reverted to normal are likely to stay in long-term remission. Assessment of {sup 99m}Tc thyroid uptake and TSH levels following completion of carbimazole therapy for Graves` disease offers useful information regarding long-term prognosis. (orig.)

  14. Evaluation of inflammatory processes in temporomandibular joint employing technetium-99m-labelled autologous leukocytes in an animal model; Avaliacao de processos inflamatorios na articulacao temporomandibular empregando leucocitos autologos marcados com tecnecio-99m em modelo animal

    Energy Technology Data Exchange (ETDEWEB)

    Brasileiro, Claudia Borges [Centro Universitario Newton Paiva, Belo Horizonte, MG (Brazil)]. E-mail: claudiabb.prof@newtonpaiva.br; cbbrasileiro@bol.com.br; Cardoso, Valbert Nascimento; Ruckert, Bianca [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Farmacia; Campos, Tarcisio Passos Ribeiro de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Nuclear

    2006-07-15

    Objective: the present study was aimed at identifying temporomandibular joint inflammatory processes employing technetium-99m hexamethyl propylene amine oxime (99mTc-HMPAO)-labeled autonomous leukocytes. Materials and methods: we have utilized an experimental model of arthritis induction in ten adult male New Zealand rabbits by means of ovalbumin intra-articular injection into each left temporomandibular joint. For control purposes, saline solution was injected. After leukocytes radiolabeling with 99mTc-HMPAO and injection into rabbits, scintigraphic images were obtained. Results: a higher 99mTc-HMPAO-leukocytes uptake was observed in left temporomandibular joint in comparison with the contralateral joint. Wilcoxon non-parametric test was applied for statistical analysis. There was a statistically significant difference between counts of radioactivity per minute in the inflamed joint and the contralateral one (p = 0.0073). Conclusion: the method employing 99mTc-HMPAO-labelled autologous leukocytes allows an early and accurate detection of inflammatory processes, contributing to the adoption of a therapeutic conduct for patients before structural alterations have occurred. (author)

  15. Dynamic 99mTc-MAG3 renography: images for quality control obtained by combining pharmacokinetic modelling, an anthropomorphic computer phantom and Monte Carlo simulated scintillation camera imaging

    Science.gov (United States)

    Brolin, Gustav; Sjögreen Gleisner, Katarina; Ljungberg, Michael

    2013-05-01

    In dynamic renal scintigraphy, the main interest is the radiopharmaceutical redistribution as a function of time. Quality control (QC) of renal procedures often relies on phantom experiments to compare image-based results with the measurement setup. A phantom with a realistic anatomy and time-varying activity distribution is therefore desirable. This work describes a pharmacokinetic (PK) compartment model for 99mTc-MAG3, used for defining a dynamic whole-body activity distribution within a digital phantom (XCAT) for accurate Monte Carlo (MC)-based images for QC. Each phantom structure is assigned a time-activity curve provided by the PK model, employing parameter values consistent with MAG3 pharmacokinetics. This approach ensures that the total amount of tracer in the phantom is preserved between time points, and it allows for modifications of the pharmacokinetics in a controlled fashion. By adjusting parameter values in the PK model, different clinically realistic scenarios can be mimicked, regarding, e.g., the relative renal uptake and renal transit time. Using the MC code SIMIND, a complete set of renography images including effects of photon attenuation, scattering, limited spatial resolution and noise, are simulated. The obtained image data can be used to evaluate quantitative techniques and computer software in clinical renography.

  16. Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201

    International Nuclear Information System (INIS)

    Sinusas, A.J.; Watson, D.D.; Cannon, J.M. Jr.; Beller, G.A.

    1989-01-01

    The myocardial uptake of a new technetium-99m-labeled myocardial perfusion agent, methoxyisobutyl isonitrile (Tc-99m MIBI), and thallium-201 was correlated with microsphere flow in an open chest canine model of low coronary flow and postischemic dysfunction. Eighteen dogs were given an injection of thallium-201 (0.5 mCi) and Tc-99m MIBI (5 mCi) either after 40 min of partial left anterior descending artery occlusion (Group I, 10 dogs) or during reperfusion after 15 min of left anterior descending artery occlusion (Group II, 8 dogs). Regional dysfunction was documented during injection in both groups by quantitative two-dimensional echocardiography. Regional blood flow was assessed by radiolabeled microspheres. The heart was excised 15 min after radionuclide injection and the left ventricle divided into 96 segments for gamma well counting. Among Group I dogs, central ischemic thallium-201 and Tc-99m MIBI activity (expressed as a percent of the activity in the corresponding nonischemic zone) was comparable, respectively, for endocardial (54 +/- 17% and 52 +/- 17%), mid-wall (71 +/- 20% and 69 +/- 17%) and epicardial (89 +/- 13% and 94 +/- 9%) segments and increased proportionally with flow. There was a good linear correlation among these endocardial segments between flow and both thallium-201 (r = 0.78) and Tc-99m MIBI (r = 0.85) activity. Among Group II dogs, central ischemic endocardial flow (59 +/- 14%) was comparable to thallium-201 (70 +/- 18%) and Tc-99m MIBI (74 +/- 12%) activity. Similarly, relative endocardial flow in the intermediate ischemic region (71 +/- 11%) was comparable to thallium-201 (77 +/- 11%) and Tc-99m MIBI (81 +/- 10%) activity. Thus, myocardial uptake of Tc-99m MIBI and thallium-201 is comparable under conditions of low coronary flow and postischemic dysfunction and closely parallels flow alterations

  17. Study to improve the precision of calculation of split renal clearance by gamma camera method using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Tomomitsu, Tatsushi; Yanagimoto, Shinichi

    1999-01-01

    Both fundamental and clinical studies were performed to improve the precision with which split renal clearance is calculated from the relation between renal clearance and the total renal uptake rate by using 99m Tc-MAG 3 , which is mainly excreted into the proximal renal tubules. In the fundamental study, the most suitable kidney phantom threshold values for the extracted renal outline were investigated with regard to size, radioactivity, depth of the kidney phantom, and radioactivity in the background. In the clinical study, suitable timing to obtain additional images for making the ROI and the standard point for calculation of renal uptake rate were investigated. The results indicated that, although suitable threshold values were distributed from 25% to 45%, differences in size, solution activity, and the position of the phantom or BG activity did not have significant effects. Comparing 1-3 min with 2-5 min as the time for additional images for ROI, we found that renal areas using the former time showed higher values, and the correlation coefficient of the regression formula improved significantly. Comparison of the timing for the start of data acquisition with the end of the arterial phase as a standard point of calculating renal uptake rate showed improvement in the latter. (author)

  18. Brain single-photon emission tomography with technetium-99m hexamethylpropylene amine oxime in adolscents with intial-stage schizophrenia

    International Nuclear Information System (INIS)

    Batista, J.F.; Galiano, M.C.; Torres, L.A.; Hernandez, M.C.; Sosa, F.; Perera, A.; Perez, M.

    1995-01-01

    The objective of this study was to search for regional cerebral blood flow (rCBF) abnormalities in adolescents with initial-stage schizophrenia by means of brain single-photon emission tomography (SPET) using technetium-99m hexamethylpropylene amine oxime (HMPAO). SPET studies were performed on a homogeneous sample of 15 carefully selected adolescents with a recent diagnosis of schizophrenia, and without previous electroconvulsive or antipsychotic drug treatment. Computed tomography (CT) and electro-encephalographic (EEG) studies were performed in all patients. Qualitative and semiquantitative analysis of 99m Tc-HMPAO SPET studies showed an impaired rCBF in 12 patients (80%). The most common pattern was a decreased uptake of 99m Tc-HMPAO in the frontal lobes, usually in the left hemisphere. Conventional and quantitative EEG was positive in 12 (80%) and 15 (100%) patients, respectively. CT findings were positive in two patients (13%). There was a high level of concordance between SPET and EEG results and between SPET and clinical features (P > 0.05). This study suggests that previously untreated patients in the first stages of schizophrenia present functional abnormalities that are revealed by brain SPET. (orig.)

  19. Chemical Speciation of Long-lived Radionuclide Technetium-99 and its Environmental Behaviour

    DEFF Research Database (Denmark)

    Shi, Keliang

    issue for understanding its fate and behaviour in ecosystem. This thesis aims to develop series of analytical methods for rapid and accurate determination of total 99Tc in environmental samples (e.g., seaweed, soil, and seawater), as well as speciation analysis of 99Tc in seaweeds. The application of 99...... - sorption at different concentrations of H+ was deduced. With the application of two small TEVA columns (1.5 mL for each), decontamination factors of >104 for molybdenum and >105 for ruthenium and recovery of 60-95% for technetium were achieved for different environmental samples. An absolute detection...

  20. Experimental study and quality control of a technetium-99 generator

    International Nuclear Information System (INIS)

    Jimeno de Osso, F.

    1981-01-01

    The performarce of a generator of technetium-99m to be used in nuclear medicine is studied. The most interesting characteristic of this generator is the use of a U-shaped chromatographuc column so as to improve its efficiency and design without increasing the weight of its shield. With the aim of improving certain aspects of the generator, molibdenum-99 was applied to adecuate pH, pirogens were removed from the column set up before application, application was effected on a dry column, the smallest alumina particles were separated on the column, etc. The most important parameters of an isotopic generator are studied, and the corresponding quality controls performed. (author)

  1. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  2. 99mTc-sucralfate scintigraphy in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Mortensen, P.B.; Lech, Y.; Moeller-Petersen, J.; Vilien, M.; Fallingborg, J.; Ekelund, S.

    1989-01-01

    Technetium-99m-labelled albumin-sucralfate was orally administered to 11 patients (Crohn's disease, 8; ulcerative colitis, 3) and 3 healthy volunteers. Serial scintigraphy was performed, and scintigraphic interpretations were compared with radiographic end endoscopic findings in an open study. It was not possible in any patient to relate the scintigraphic findings to the localizations of inflammatory bowel disease, nor was it possible to distinguish the scans in the patients from the scans of the healthy volunteers. It is concluded the 99m Tc-albumin-sucralfate scintigraphy is of no value in the detection of inflammatory bowel disease. 8 refs

  3. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P histogram equalization technique in combination with some other postprocessing technique is useful.

  4. Clinical significance of technetium-99m stannous pyrophosphate myocardial scintigrams in patients with acute and old myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Ikuo; Eno, Shin; Takeuchi, Masaaki

    1987-08-01

    Seventy-five consecutive patients with acute (43) or old (32) myocardial infarction (AMI, OMI) have been examined by myocardial scintiscanning with technetium-99m stannous pyrophosphate (PYP). Using Parker's classification, the PYP scans were graded as positive in 56 % of the AMI patients; in restricting to the PYP scans obtained within the first 3 days after the onset, the positive rate was 86 %. Positive or negative PYP scans for the AMI patients were independent of maximum creatine phosphokinase and infarct site. For OMI patients, the PYP scans were positive in 41 %, with decreased left ventricular function being more common than those having negative PYP scans. In the group of positive scans, clinical manifestations tended to be remarkable, which were likely due to persistent cardiac ischemia during chronic stage. (Namekawa, K.).

  5. Evaluation of the effect of an extract of sabugueiro (Sambucus australis) on the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Ribeiro, Camila Godinho; Rebello, Bernardo Machado; Neves, Rosane de Figueiredo; Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Medeiros, Aldo da Cunha; Bernardo-Filho, Mario; Catanho, Maria Teresa Jansem de Almeida

    2007-01-01

    Sambucus australis (sabugueiro) has been used to treat inflammatory and rheumatologic disorders. Blood constituents labeled with technetium-99m (99mTc) have been used in nuclear medicine to obtain diagnostic images. The aim of this work was to evaluate the effect of a sabugueiro extract on the labeling of blood cells with 99mTc. Blood samples from Wistar rats were incubated with sabugueiro extract and the radiolabeling assay of blood constituents was carried out. After centrifugation, samples of plasma and blood cells were separated. Aliquots of plasma and blood cells were precipitated with trichloroacetic acid and centrifuged to isolate soluble and insoluble fractions. The radioactivity in each fraction was counted and the percentage of activity (%ATI) was determined. Incubation with sabugueiro extract altered significantly (p<0.05) the %ATI incorporated to the blood constituents. These results could be explained due the presence of chemical substances in the sabugueiro extract that present redox and/or chelating action altering the labeling of the blood constituents with 99mTc. (author)

  6. Doses to nurses by the technetium-99m, in private and public sector

    International Nuclear Information System (INIS)

    Bied, J.Ch.; Philippon, B.

    1999-01-01

    The global body dose due to the technetium is 1.2 and 1.9 mSv for the two nurses of the private sector. In the public sector, the level reached by the personnel is 0.75 mSv for the global body dose, and the only technetium (global body dose 1.4 and 2.1 mSv for the private sector, 0.95 for the public sector and for the whole of radiations measured by the O.P.R.I. film dosemeter. The doses received at the fingers level present higher levels in the private sector. But these values, 15.2 and 10.7 mSv by month, that is to say 180 mSv by year are the 2/5 of the maximum permissible value. The two persons of the private sector received whole body doses, higher that the doses of the public sector. These doses are about 1.2 to 1.9 these ones received in the public sector. (N.C.)

  7. An extract of a formula used in the traditional chinese medicine (Buzhong Yi Qi Wan) alters the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Giani, Tania Santos; Paoli, Severo de; Brandao-Neto, Jose; Medeiros, Aldo da Cunha; Presta, Giuseppe Antonio; Maiworm, Adalgisa Ieda; Santos Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2007-01-01

    Buzhong Yi Qi Wan (Buzhong) is a medicinal herb widely used in Traditional Chinese Medicine to treat the digestive and circulatory systems. Red blood cell and plasma proteins labeled with technetium-99m ( 99m Tc) are used in nuclear medicine. The aim of this work was to investigate the effects of an aqueous Buzhong extract on the labeling of blood constituents with 99m Tc. Heparinized blood (Wistar rats) was incubated in vitro with different Buzhong extract concentrations and 99m Tc-labeling was performed. Plasma (P) and blood cells (BC) were separated and soluble (SF-P, SF-BC) and insoluble (IF-P, IF-BC) fractions were isolated. The radioactivity on blood constituents was determined and the percentage of incorporated radioactivity (%ATI) was calculated. Buzhong extract at the highest concentrations used altered significantly (p 99 mTc. (author)

  8. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  9. Usefulness of technetium-99m tetrofosmin single-photon emission computed tomography for short-term risk stratification in patients with acute chest pain in the emergency room

    International Nuclear Information System (INIS)

    Kawahito, Michitomo; Kondo, Makoto; Abe, Yoshiteru

    2003-01-01

    High-risk patients with acute coronary syndrome are difficult to distinguish from low-risk patients with chest pain in the emergency room. Technetium-99 m ( 99m Tc) tetrofosmin single-photon emission computed tomography (SPECT) was investigated to exclude high-risk patients with chest pain in the emergency room. 99m Tc-tetrofosmin SPECT was evaluated using a four-point scoring system in 228 patients (144 men, 84 women, mean age 68±12 years) with chest pain. Negative was defined as the myocardial segments with a defect score (DS) of 99m Tc-tetrofosmin; no significance (NS)), 84.9% (NS) and 60.4% (p 99m Tc-tetrofosmin SPECT is a useful method to exclude high-risk patients among patients with chest pain in the emergency room. (author)

  10. Determination of technetium-99 in environmental standard reference materials by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Technetium-99 is an artificial radionuclide which is produced in the fission of 235 U or 239 Pu with a relatively high fission yield of ca. 6%. Because of its long half-life of 2.1 x 10 5 y, 99 Tc has been accumulating in the environment, and thus, is considered to present a potential risk for humans. It is important for dose assessments to identify the behavior of the nuclide in the environment. Analysis data of global fallout 99 Tc in environmental samples would give useful information for predicting the nuclide's behavior; however, due to its low concentration and analytical difficulties, not much data are available. Besides, no environmental standard reference material (SRM) for 99 Tc is available. If we could get suitable SRMs for 99 Tc analysis, it would be easier to determine the concentration of 99 Tc in environmental samples. The purpose of this study was to investigate the possibility of several SRMs to be used as references for low-level 99 Tc. For this, ICP-MS was used for 99 Tc determination. In recent years, ICP-MS has been used for 99 Tc measurements instead of radioactivity counting methods. The samples used were as follows: A) IAEA-373 (a grass sample collected on grassland near Chernobyl Nuclear Power Reactor, Ukraine), B) IAEA-375 (a soil sample collected on a field near Chernobyl Nuclear Power Reactor, Russia), C) IAEA-135 (a sea sediment sample affected by Sellafield, UK), D) five seaweed samples of which the concentration levels are different from each other (collected around the coast near Sellafield, UK). Throughout the chemical separation, 95m Tc was used as a yield monitor. The sample was incinerated for at least 2 h at 450degC. After 99 Tc extraction from the sample at 90degC for 3 h with 4M HNO 3 , the sample was filtered and the residue on the filter was washed with deionized water. The solution was diluted to ca. 0.1M HNO 3 then passed through TEVA resin column (EIChroM Industries, Inc.) to extract Tc onto the resin. Then Tc was

  11. A new plastic scintillation resin for single-step separation, concentration and measurement of technetium-99

    International Nuclear Information System (INIS)

    Barrera, J.; Tarancón, A.; Bagán, H.; García, J.F.

    2016-01-01

    Technetium is a synthetic element with no stable isotopes, produced as waste in nuclear power plants and in cyclotrons used for nuclear medicine. The element has high mobility, in the form of TcO_4"−; its determination is therefore important for environmental protection. Technetium is found in low concentrations and therefore common methods for its analysis include long treatments in several steps and require large amounts of reagents for its purification and preconcentration. Plastic scintillation resins (PSresin) are novel materials used to separate, preconcentrate and measure radionuclides in a single step. The objective of this study is to prepare and characterise a PSresin for the preconcentration and measurement of "9"9Tc. The study first evaluates the reproducibility of the production of PSresins between batches and over time; showing good reproducibility and storage stability. Next, we studied the effect of some common non-radioactive interferences, showing small influences on measurement, and radioactive interferences ("3"6Cl and "2"3"8U/"2"3"4U). "3"6Cl can be removed by a simple treatment with 0.5 M HCl and "2"3"8U/"2"3"4U can be removed from the column by cleaning with a mixture of 0.1 M HNO_3 and 0.1 M HF. In the latter case, a slight change in the morphology of the PSresin caused an increase in detection efficiency. Finally, the PSresin was applied to the measurement of real spiked samples (sea water and urine) with deviations lower than 10% in all cases. - Highlights: • A plastic scintillation resin for selective analysis of "9"9Tc has been developed. • The method is valid for analysis of "9"9Tc in seawater and urine samples. • Presence of Cl"−, NO_3"−, SO_4"2"−, "3"6Cl, U and Th not affect retention of "9"9Tc.

  12. Comparison of uteroplacental blood flow in normal and pre-eclamptic patients measurement with technetium-99m and a computer-linked gamma camera

    International Nuclear Information System (INIS)

    Cho, S.H.; Moon, H.; Kim, D.S.; Cho, S.S.

    1985-01-01

    Uteroplacental blood flow studies in preeclampsia are of special interest since the vascular changes reported in this disease might constitute a structural basis for a reduction of blood flow. Evidence has also been given for a decreased uteroplacental blood flow in preeclampsia. Among the various methods to estimate the maternal placental blood flow, the one most frequently reported in the literature during the last years has been the time activity analysis of short lived radiotracer such as technetium-99m or indium-113m injected intravenously. Only few studies with the above mentioned technique comparing normal and preeclampsia cases have been undertaken. In clinical practice we frequently experience difficuly in finding the optimal time to get the delivery in preeclampsia patients. The aim of this study was first to measure uteroplacental blood flow in preeclamptic pregnancies using a computer-linked gamma camera method for the time-activity analysis of technetium-99m and second to discuss the possibility of clinical application of these measurements for determination of fetal well-being and the timing of the delivery in these patients. Uteroplacental blood flow was measured from 13 preeclamptic patients and 19 pregnancies without any complication after 35 completed weeks of gestation from Jan. 1983 to Sep. 1983 at Obstetrics department of Hanyang University Hospital. (Author)

  13. Comparison of uteroplacental blood flow in normal and pre-eclamptic patients measurement with technetium-99m and a computer-linked gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S.H.; Moon, H.; Kim, D.S.; Cho, S.S.

    1985-05-01

    Uteroplacental blood flow studies in preeclampsia are of special interest since the vascular changes reported in this disease might constitute a structural basis for a reduction of blood flow. Evidence has also been given for a decreased uteroplacental blood flow in preeclampsia. Among the various methods to estimate the maternal placental blood flow, the one most frequently reported in the literature during the last years has been the time activity analysis of short lived radiotracer such as technetium-99m or indium-113m injected intravenously. Only few studies with the above mentioned technique comparing normal and preeclampsia cases have been undertaken. In clinical practice we frequently experience difficuly in finding the optimal time to get the delivery in preeclampsia patients. The aim of this study was first to measure uteroplacental blood flow in preeclamptic pregnancies using a computer-linked gamma camera method for the time-activity analysis of technetium-99m and second to discuss the possibility of clinical application of these measurements for determination of fetal well-being and the timing of the delivery in these patients. Uteroplacental blood flow was measured from 13 preeclamptic patients and 19 pregnancies without any complication after 35 completed weeks of gestation from Jan. 1983 to Sep. 1983 at Obstetrics department of Hanyang University Hospital. (Author).

  14. Pharmacokinetics of labelled compounds with technetium-99m and samarium-153

    International Nuclear Information System (INIS)

    Borda O, L.B.; Torres L, M.N.

    1997-01-01

    The purpose of this investigation was to establish the different pharmacokinetics parameters of the main radiopharmaceuticals labeled with technetium-99m and samarium-153. These parameters could be subsequently used as reference to compare other products with the same use. Mathematical models and a computerized pharmacokinetic program were used to this purpose. A biodistribution study in quadruplicate and/or quintuplicate was conducted for each radiopharmaceutical, data was was obtained in injection dose percentages. The biodistribution study involved the injection of a predetermined dose of the radiopharmaceutical into animals (rats or mice), which were subsequently put away at different time intervals, removing the relevant organs. Activity in each organ was read by means of a well-type NaI scintillation counter, data obtained in activity counts was transformed into injection dose percentages. Based on these percentages, the mathematical model was constructed and the pharmacokinetic parameters were obtained using the computerized program Expo 2 v. 1, which is written in C language and works in windows. Analyzing the results obtained, we can conclude that the use of the Expo 2 v. 1 program for a bi compartmental analysis allowed us to obtain reliable pharmacokinetic parameters which describe what happens in the organism when the radiopharmaceutical passes from the central compartment to the peripheral one and vice versa

  15. Technetium-99m-hexakis-2-methoxyisobutylisonitrile scintigraphy and multidrug resistance-related protein expression in human primary lung cancer

    International Nuclear Information System (INIS)

    Duan Xiaoyi; Wang Jiansheng; Liu Min; Guo Youmin

    2008-01-01

    The occurrence of multidrug resistance (MDR) is a major cause of resistance to chemotherapeutic agents in patients with lung cancer, in part owing to the overexpression of MDR-related proteins. Technetium-99m-hexakis-2-methoxyisobutylisonitrile ( 99m Tc-MIBI) has been shown to be a substrate for some MDR-related proteins. The aim of this study is to evaluate the role of 99m Tc-MIBI scintigraphy for functional imaging of MDR-related protein phenotypes. To determine the correlation between 99m Tc-MIBI scintigraphy and the expression level of P-glycoprotein (Pgp), multidrug-resistance protein (MRP), and glutathione-S-transferase Pi (GSTπ), 26 patients (17 men and 9 women, median age 57.5 years) with primary lung cancer were investigated. Following intravenous administration of 925 MBq 99m Tc-MIBI, single-photon emission computed tomography (SPECT) and computed tomography (CT) were performed at 15 min and 2 h. On the basis of the fused images, tumor to background (T/B) ratio of both early and delayed images, and washout rate (WR%) of 99m Tc-MIBI were calculated. The immunohistochemical staining of Pgp, MRP, and GSTπ was performed, and the expression level was semiquantitated using a pathoimage analysis system. The imaging results were compared with the status of Pgp, MRP, and GSTπ expression. The WR% of 99m Tc-MIBI showed a significant positive correlation with Pgp expression (r=0.560, P=0.003), as no correlation was observed between WR% and MRP or GSTπ (r=0.354, P=0.076; r=0.324, P=0.106). Neither early T/B nor delayed T/B correlated with the expression level of Pgp, MRP, and GSTπ. WR%, Pgp, and GSTπ expression showed significant differences between squamous cell carcinoma (group A) and adenocarcinoma (group B). There was no significant difference among Pgp, MRP, and GSTπ expression levels in any cases (P>0.05). Our data confirmed that 99m Tc-MIBI scintigraphy is useful for determining the MDR caused by Pgp in patients with primary lung cancer. (author)

  16. Scintigraphic study of palpable breast nodes with 99m Tc-tetrofosmin

    International Nuclear Information System (INIS)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da; Amarante Junior, Jose Luiz de Medeiros; Fabricio, Maria Ines Menescal

    1998-01-01

    In Brazil, breast carcinoma has the greater incidence among women. In 1996, about 31,210 new cases were diagnosed. The purpose of this study is to determine if 99m technetium-tetrofosmin preferentially concentrates within malignant palpable breast nodes, distinguishing them from the benign lumps. Fifth-four consecutive and unsolicited women, mean age 47.5 +- 10.7 years, with palpable nodes in breast, underwent breast scintigraphy with 99m technetium-tetrofosmin and excisional biopsy or fine needle puncture within interval eight weeks. Histopathologic studies demonstrated 13 cysts, 1 cyst with local inflammation, 11 fibroadenoma, 2 fibrodysplasias, 3 fibroadenomas with high cellularity, 1 fibrocystic change with local inflammation, 23 invasive intraductal carcinomas and 1 invasive lobular carcinoma. The nodes ranged from 10 to 100 mm in greater diameter. The scintigraphic study yielded 30 true-negative cases, 24 true-positives, no false-negative and 1 false-positive. This case was a fibrocystic lump with local inflammation. Two patients had metastases in axillary lymph nodes, well detected in scintigraphy. The statistic analysis showed: sensitivity, 100%; specificity, 96.8%; accuracy, 98.2%; negative predictive value, 100%; positive predictive value, 96.0%. Nonparametric tests of Fisher and Chi-square rejected the antithesis at a confidence interval of 99.9% (p 99m technetium-tetrofosmin preferentially concentrates in malignant palpable breast nodes and can help to distinguish them from the benign tumors with with very high accuracy. (author)

  17. MAG2GABA-biocytin synthesized with new intermediates for radiolabelling 99mTc and 188Re

    International Nuclear Information System (INIS)

    Ahn, S.H.; Choi, T.H.; Choi, C.W.; Yang, S.D.; Woo, K.S.; Chung, W.S.; Lim, S.M.

    2001-01-01

    188 Re from 188 W- 188 Re generator, is recently introduced in therapeutic nuclear medicine and made it possible to use whenever needed. We synthesized MAG 2 GABA-Biocytin (MGB), labelled with 188 Re for pretargeted radioimmunotherapy and evaluated biological behavior of 188 Re-MGB. N-hydroxysuccinimidyl ester of S-benzoyl mercaptoacetyldiglycine (NHS-MAG 2 ) was synthesized first, reacted with aminobutyric acid(GABA) to give MAG 2 GABA and then converted to NHS-MAG 2 GABA and conjugated to biocytin to give the MGB. To label MGB with 188 Re (50mA), ag, 200ml 1M tartrate pH7, 200 l stannous (10mg/mL) and 180MBq perrhenate were mixed and heated for 30min at 100 deg. C. The reactant was purified with C 18 Sep-Pak. HPLC analysis of the 188 Re-MGB performed on reverse phase C 18 column with a gradient. To see the stability, 188 Re-MGB was added to serum at 37 deg. C. Binding capacity of 188 Re-MGB to avidin or streptavidin was determined by size exclusion HPLC system. Biodistribution was studied in ICR normal mice(n=4/group), from 5min to 120min. In Raji cells tumour bearing nude mice(n=3), biotinylated Lym-1(40MEG) injection after 48 h, streptavidin(50MEG) was injected. 24 h later, 188 Re-MGB(0.5MEG) was injected, and biodistribution was observed 2 h later. 188 Re-MGB was obtained with labelling yield 98%. Stability in serum was maintained over 70% until 3 h. Binding capacity of 188 Re-MGB to streptavidin was greater than avidin. In normal mice, 188 Re-MGB was excreted via hepatobiliary pathway,%ID/g of GI tract was 52.1 at 120min. In Raji cells tumour bearing nude mice, liver and colon were higher than those of normal mouse. Tumour uptake at 120min was 0.05%ID/g. 188 Re-MGB was effectively labelled and retained binding activity with streptavidin. 188 Re-MGB may have a role in pretargeted radioimmunotherapy. (author)

  18. A comparative technetium 99m hexamethylpropylene amine oxime SPET study in different types of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Habert, M.O.; Piketty, M.L.; Askienazy, S. (Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Medecine Nucleaire); Spampinato, U.; Mas, J.L.; Recondo, J. de; Rondot, P. (Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Neurologie); Bourdel, M.C. (Centre Hospitalier Sainte-Anne, 75 - Paris (France). Dept. de Psychiatrie)

    1991-01-01

    Regional cerebral perfusion was evaluated by single photon emission tomography (SPET) using technetium 99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) as a tracer, in 13 control subjects and 44 age-matched patients suffering from dementia of the Alzheimer's type (DAT, n=19) presumed Pick's disease (n=5), idiopathic Parkinson's disease with dementia (DPD, n=15) and progressive supranuclear palsy (PSP, n=5), HMPAO uptake was measured in the superior frontal, inferior frontal, parietal, temporal and occipital cortices, and the perfusion values were expressed as cortical/cerebellar activity ratios. As compared with controls, tracer uptake ratios in the DAT group were signficantly reduced over all cortical regions, with the largest defects in the parieto-temporal and superior frontal cortices. A marked hypoperfusion affecting the superior and inferior frontal cortices was found in Pick's diesease, whereas a mild but significant hypoperfusion was observed only in the superior frontal cortex of patients with PSP. In the DPD group, HMPAO uptake was significantly reduced in the parietal, temporal and occipital cortices, but not in the frontal cortex. These results show that DAT and DPD share the opposite anteroposterior HMPAO uptake defect as compared with the Pick's and PSP groups. (orig.).

  19. High power targets for cyclotron production of 99mTc‡

    OpenAIRE

    Zeisler, S. K.; Hanemaayer, V.; Buckley, K. R.; Hook, B. K.; MeDiarmid, S.; Klug, J.; Corsaut, J.; Kovacs, M.; Cockburn, N.; Exonomou, C.; Harper, R.; Valliant, J. F.; Ruth, T. J.; Schaffer, P.

    2015-01-01

    Introduction Technetium-99m, supplied in the form of 99Mo/99mTc generators, is the most widely used radioisotope for nuclear medical imaging. The parent isotope 99Mo is currently produced in nuclear reactors. Recent disruptions in the 99Mo supply chain [1] prompted the development of methods for the direct accelerator-based production of 99mTc. Our approach involves the 100Mo(p,2n)99mTc reaction on isotopically enriched molybdenum using small medical cyclotrons (Ep ≤ 20 MeV), which is ...

  20. Influence of some drugs, used in coronary artery disease on in vitro labelling red blood cells with technetium 99mTc

    International Nuclear Information System (INIS)

    Poniatowicz-Frasunek, E.

    1997-01-01

    In some patients investigated by radionuclide ventriculography poor labeling efficiency of red blood cells with technetium 99m Tc is observed. Among possible mechanisms responsible for this phenomenon, the pharmacological treatment applied to the patients should be taken into consideration. The aim of the study was to define the effect of selected drugs used in CAD on technetium binding efficiency by erythrocytes in vitro. Blood samples were obtained from 40 normal individuals receiving no medication. The effect of the following drugs were examined: Aerosonit, Isoptin, Bemecor, Dopegyt, Enarenal, Binazin, Furosemid, Aspirin, Vitamin E and Propranolol. Only Enarenal and Vitamin E proved to have no effect on technetium binding efficiency. The most expressed reduction was observed in experiments with Aerosonit, Furosemid and Propranolol and the smallest changes were found in blood samples with Bemecor, Binazin and Aspirin. The results of the study suggest that pharmacological treatment may influence the quality of scintigraphic images obtained with radioisotope ventriculography. For that reason the medicines applied to the patients should be as much as possible reduced or withdrawn for at least several days before examination. (author)

  1. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Nuclear Medicine, University of l`Aquila (Italy); Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L. [Department of Clinical Medicine, University ``La Sapienza``, Rome (Italy); Danieli, R.; Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1999-07-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with {sup 99m}Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (``reverse redistribution pattern``). Coronary angiography was performed in eight patients with positive {sup 99m}Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that {sup 99m}Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole {sup 99m}Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.) With 2 figs., 2 tabs., 21 refs.

  2. Technetium-99m sestamibi single-photon emission tomography detects subclinical myocardial perfusion abnormalities in patients with systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Schillaci, O.; Lagana, B.; Gentile, R.; Tubani, L.; Baratta, L.; Danieli, R.; Scopinaro, F.

    1999-01-01

    In patients with systemic lupus erythematosus, involvement of the cardiovascular system is the third leading cause of death. However, although autopsy studies have demonstrated a high incidence of abnormalities in both the myocardium and coronary vessels, clinical manifestations have been reported in only a small percentage of cases. The aim of this study was to evaluate myocardial perfusion in asymptomatic lupus patients using technetium-99m sestamibi single-photon emission tomography (SPET). Twenty-eight patients without overt cardiac involvement and risk factors were studied with 99m Tc-sestamibi SPET at rest and after dipyridamole infusion. Perfusion abnormalities were detected in 18 cases: six had persistent defects, three had reversible defects, seven had both persistent and reversible defects, and two showed rest defects which normalized on dipyridamole images (''reverse redistribution pattern''). Coronary angiography was performed in eight patients with positive 99m Tc-sestamibi SPET, and showed normal epicardial vessels in all the cases. These results indicate that 99m Tc-sestamibi SPET reveals a high prevalence (18 out of 28 patients in this study, i.e. 64%) of myocardial perfusion abnormalities in asymptomatic lupus patients, probably due to the primary immunological damage of this autoimmune disease. In conclusion, rest/dipyridamole 99m Tc-sestamibi SPET can be a useful non-invasive method to identify subclinical myocardial involvement in systemic lupus erythematosus, and patients potentially at risk of later cardiac events. (orig.)

  3. Consequences of the magnetic field, sonic and radiofrequency waves and intense pulsed light on the labeling of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Meyer, Patricia Froes; Costa, Iris do Ceu Clara; Brandao-Neto, Jose; Medeiros, Aldo da Cunha; Bonelli, Ludmila

    2007-01-01

    Sources of magnetic field, radiofrequency and audible sonic waves and pulsed light have been used in physiotherapy to treat different disorders. In nuclear medicine, blood constituents(Bl-Co) are labeled with technetium-99m ( 99m Tc) are used. This study evaluated the consequences of magnetic field, radiofrequency and audible sonic waves and intense pulsed light sources on the labeling of Bl-Co with 99m Tc. Blood from Wistar rats was exposed to the cited sources. The labeling of Bl-Co with 99m Tc was performed. Blood not exposed to the physical agents was used(controls). Data showed that the exposure to the different studied sources did not alter significantly (p>0.05) the labeling of Bl-Co. Although the results were obtained with animals, the data suggest that no alteration on examinations performed with Bl-Co labeled with 99m Tc after exposition to the cited agents. The biological consequences associated with these agents would be not capable to interfere with some properties of the Bl-Co. (author)

  4. Consequences of the magnetic field, sonic and radiofrequency waves and intense pulsed light on the labeling of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Patricia Froes; Costa, Iris do Ceu Clara; Brandao-Neto, Jose; Medeiros, Aldo da Cunha [Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil). Programa de Pos-graduacao em Ciencias da Saude; Santos-Filho, Sebastiao David; Adenilson de Souza da Fonseca; Bernardo-Filho, Mario [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Ariel Ronzio, Oscar [Universidad de Buenos Aires (Argentina); Bonelli, Ludmila [Universidade Salgado de Oliveira, Belo Horizonte, MG (Brazil)

    2007-09-15

    Sources of magnetic field, radiofrequency and audible sonic waves and pulsed light have been used in physiotherapy to treat different disorders. In nuclear medicine, blood constituents(Bl-Co) are labeled with technetium-99m ({sup 99m}Tc) are used. This study evaluated the consequences of magnetic field, radiofrequency and audible sonic waves and intense pulsed light sources on the labeling of Bl-Co with {sup 99m}Tc. Blood from Wistar rats was exposed to the cited sources. The labeling of Bl-Co with {sup 99m}Tc was performed. Blood not exposed to the physical agents was used(controls). Data showed that the exposure to the different studied sources did not alter significantly (p>0.05) the labeling of Bl-Co. Although the results were obtained with animals, the data suggest that no alteration on examinations performed with Bl-Co labeled with {sup 99m}Tc after exposition to the cited agents. The biological consequences associated with these agents would be not capable to interfere with some properties of the Bl-Co. (author)

  5. Myocardial perfusion scintigraphy with technetium99m-MIBI in the diagnosis of coronary artery disease in women

    International Nuclear Information System (INIS)

    Peix, A.T.; Chacon, D.; Ponce, F.; Torres, M.; Llerena, L.; Lopez, A.; Cabrera, O.; Maltas, A.M.; Carrillo, R.

    2002-01-01

    Aim: To assess the value of myocardial perfusion scintigraphy for coronary artery disease (CAD) in women, we compared the results of a technetium99m-methoxy-isobutyl-isonitrile ( 99m Tc-MIBI) scintigraphy with those of a coronary angiography in a group of women referred for evaluation of chest pain. Material and Methods: Twenty women, 15 of them postmenopausal, were included. A 99m Tc-MIBI myocardial scintigraphy with one-day protocol (rest-stress) was performed. When needed, a combined stress (ergometric plus dipyridamole) was used. Both qualitative and quantitative regional uptake analysis was done. In patients with normal coronary arteries and positive myocardial scintigraphies, measurements were made of serum cholesterol and triglycerides (CHOD-PAD enzymatic colorimetric test), and lipoprotein(a) -Lp(a)- (BioSCREEN Lp(a) method). Results: Change in regional uptake (stress/rest) was as follows: during stress 99m Tc-MIBI, 116 segments had normal uptake (from 93±9% to 94±7%), 52 had moderately reduced uptake (from 67±9% to 75±17%), and 12 had severely reduced uptake (from 33±9% to 64±28%). Qualitative and quantitative analysis coincided in 18 cases. The two non-coincident cases were patients in whom qualitative analysis and coronary angiography were normal, but on quantitative analysis it appeared a reversible defect in one case and a 'reverse redistribution' pattern in the other. Breast attenuation defects were detected in four cases. Myocardial scintigraphy and coronary angiography coincided in 70% cases (figure). The remainder 30% was constituted by patients with positive scintigraphy and normal coronary arteries; among these cases, the 71% were postmenopausal and had systolic hypertension, chest pain at rest, positive ergometric test and hypercholesterolemia (table). Conclusion: We concluded that 99m Tc-MIBI myocardial scintigraphy can help in the CAD diagnosis in postmenopausal women

  6. Study of the leaf extract of cauliflower (Brassica oleracea L. var. Botrytis) in the blood elements labelling using Technetium-99m: possible consequences for the radiation dose modification

    International Nuclear Information System (INIS)

    Lima, E.A.C.; Dire, G.; Mattos, D.M.M.; Gomes, M.L.; Freitas, R.S.; Bernardo Filho, M.; Instituto Nacional do Cancer, Rio de Janeiro, RJ

    2001-01-01

    The radiation dose that a patient receives is also associated with the number of expositions to radiation sources. The labeling of blood elements with technetium-99m can be reduced by vegetable extracts and it can determine the repetition of the exam. The labeling procedure depends on a reducing agent and stannous chloride is used. We have evaluated the influence of an extract of cauliflower (leaf) on the labeling of blood elements with technetium-99m the and the results showed that this extract was not capable to alter the labeling procedure, suggesting that the studied extract does not have redox activity sufficiently to oxidize the stannous ions. Moreover, although, other natural extracts might alter this labeling, increasing the radiation dose to the patient, this fact would not occur to the cauliflower. (author)

  7. Simultaneous 99mTC and 123I Dual-Isotope Brain Striatal Phantom Single Photon Emission Computed Tomography: Validation of 99mTC-Trodat-1 and 123I-IBZM Simultaneous Dopamine System Brain Imaging

    OpenAIRE

    Pan-Fu Kao; Shiaw-Pyng Wey; An-Shoei Yang

    2009-01-01

    [2[[2-[[[3-(4-chlorophenyl)-8-methyl-8-azabicyclo[3,2,1]-oct-2-yl]-methyl](2-mercaptoethyl)amino]ethyl]amino]ethanethiolato(3-)-N2,N2′,S2,S2]oxo-[1R-exo-exo)])-[99mTc]-technetium (99mTc-TRODAT-1) and 123I-iodobenzamide (123I-IBZM) are radiotracers for brain dopamine preand postsynaptic neuron imaging. The purpose of this study was to evaluate imaging parameters and crossed energy interference using simultaneous single photon emission computed tomography (SPECT) 99mTc and 123I data acquisition...

  8. Application of technetium-99m hexamethylpropylene amine oxime single-photon emission tomography to neurologic prognosis in patients undergoing urgent carotid surgery

    International Nuclear Information System (INIS)

    Shvera, I.Y.; Cherniavsky, A.M.; Ussov, W.Yu.; Plotnikov, M.P.; Sokolov, A.A.; Shipulin, V.M.; Chernov, V.I.

    1995-01-01

    In this study we aimed to work out a quantitative prognostic index for preoperative assessment of brain technetium-99m hexamethylpropylene amine oxime (HMPAO) single-photon emission tomography (SPET) in patients referred for urgent carotid endarterectomy due to acute abstructive disease of the internal carotid artery (ICA) and neurological deficit. To this end we compared data from preoperative SPET studies with the postinterventional changes in neurological status in 20 patients (17 males, three females; mean age 53 years, SD 4 years) with acute ischaemic cerebral disorders induced by obstruction of the ICA. Carotid obstruction was diagnosed by ultrasound B-mode study. All patients underwent urgent carotid endarterectomy from the ICA. Patients were divided into two groups in accordance with the results of postoperative follow-up: group A comprised patients with significant (more than 3 points) postoperative improvement in neurological condition as quantified by the Canadian Neurological Scale (11 patients); group B consisted of patients with minimal improvement or deterioration (nine, three of whom died). All patients were studied preoperatively by 99m Tc-HMPAO SPET. The volume of nonperfused tissue (VS, cm 3 ) was quantified using the Mountz technique. Hypoperfused volume (V hypoperf , cm 3 ) in the affected hemisphere was calculated as the total volume of voxels with 99m Tc-HMPAO uptake hypoperf ). Patients with preoperative PF values 8.90 comprised patients who demonstrated minimal improvement or deterioration. PF values in the range 8.20-8.90 carried an indefinite prognosis. (orig.)

  9. Technetium-99m-labeled deoxynivalenol from Fusarium mycotoxin alters organ toxicity in BALB/c mice by oral and intravenous route

    International Nuclear Information System (INIS)

    Chattopadhyay, P; Pandey, A; Goyary, D; Chaurasia, A; Singh, L; Veer, V.

    2012-01-01

    The toxicity of deoxynivalenol, both intravenously and orally, was investigated in male and female BALB/c mice. Technetium-99m ( 99m Tc)-labeled deoxynivalenol was administered to mice by tail vein injection and orally dosed. Distribution of labeled deoxynivalenol at 26 hours was monitored by gamma scintigraphy. In the evaluated organs, the accumulation of radioactive deoxynivalenol was correlated with the amount of radioactivity. In addition, the toxicity of deoxynivalenol was measured by biochemical assays followed by histopathological findings. Kidney and hepatic marker enzymes were significantly increased in intravenously administered deoxynivalenol as compared to orally treated mice. Intravenously treated mice showed severe damage in liver and kidney when compared to those orally exposed. Biodistribution of 99m Tc-labeled deoxynivalenol differed between oral and intravenous treatment. In intravenously exposed mice, deoxynivalenol was distributed primarily in the liver and kidney whereas in oral exposure, it was found in the stomach and intestines after 26 hours. Deoxynivalenol toxicity, associated with its biodistribution and organ toxicity, was greatest where it had accumulated. The results show that the toxicity of deoxynivalenol is associated with organ accumulation. (author)

  10. 99mTc labelled peptides for imaging peripheral receptors

    International Nuclear Information System (INIS)

    Gil, M.C.; Chandia, V.M.; Errazu, X.

    2001-01-01

    Radiolabelling of somatostatin analogues as RC-160 and TOC with 99m Tc, using direct and bifunctional chelating methods as well as quality control and evaluation methods, has been accomplished following the techniques and recommendation of the first and second RCMs. Synthesis of bifunctional chelating agents, such as Bz-MAG-3, is routinely produced in our laboratory. Synthesis of HYNIC and HYNIC-MAG-3 is in progress. Radioiodination of RC-160 using chloramine-T and iodogen methods were also studied in order to get experience with the different techniques used to evaluate the labelled peptides. (author)

  11. Study of factors that interfere in the labelling process of erythrocytes and plasma proteins with Technetium-99m; Estudo de fatores que interferem no processo de marcacao de hemacias e proteinas plasmaticas com tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Gutfilen, Bianca

    1990-12-31

    The labelling of red blood cells (RBC) with technetium-99m (Tc-99m) depends on several factors, as the stannous ion (Sn++) concentration, time, temperature, the presence of plasma proteins (PP) and others. However the Sn++ concentration seems to be the most important factor; probably because the uptake of this reducing agent by RBC is limited. The excess of Sn++ in extracellular medium can determine the labelling of PP. the modifications of RBC at 50 deg C described in the literature, the possibility of labelling RBC with Tc-99m at this temperature and experimental results obtained made it possible to perform spleen selective scintigraphy through a simple technique with few manipulations. The effect of gentamicin, nifedipine and verapamil in the labelling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca++ and Sn++. The results show that, under some conditions, these drugs are capable to alter this Tc-99m incorporation. The modification of the ionic distribution determined by these drugs or the blockage of Sn++ and/or Tc-99m or the fact that they bind theirselves to plasma proteins, or the possibility of the labelling of these drugs, are factors that can interfere in the labelling process of red blood cells and plasma proteins with Tc-99m. (author) 55 refs., 12 figs., 5 tabs.

  12. Study of factors that interfere in the labelling process of erythrocytes and plasma proteins with Technetium-99m; Estudo de fatores que interferem no processo de marcacao de hemacias e proteinas plasmaticas com tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Gutfilen, Bianca

    1989-12-31

    The labelling of red blood cells (RBC) with technetium-99m (Tc-99m) depends on several factors, as the stannous ion (Sn++) concentration, time, temperature, the presence of plasma proteins (PP) and others. However the Sn++ concentration seems to be the most important factor; probably because the uptake of this reducing agent by RBC is limited. The excess of Sn++ in extracellular medium can determine the labelling of PP. the modifications of RBC at 50 deg C described in the literature, the possibility of labelling RBC with Tc-99m at this temperature and experimental results obtained made it possible to perform spleen selective scintigraphy through a simple technique with few manipulations. The effect of gentamicin, nifedipine and verapamil in the labelling of RBC and plasma proteins with Tc-99m was studied because of similarities between Ca++ and Sn++. The results show that, under some conditions, these drugs are capable to alter this Tc-99m incorporation. The modification of the ionic distribution determined by these drugs or the blockage of Sn++ and/or Tc-99m or the fact that they bind theirselves to plasma proteins, or the possibility of the labelling of these drugs, are factors that can interfere in the labelling process of red blood cells and plasma proteins with Tc-99m. (author) 55 refs., 12 figs., 5 tabs.

  13. Status of {sup 99}Mo-{sup 99m}Tc production development by (n, {gamma}) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kunihiko; Kaminaga, Masanori; Ishihara, Masahiro; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Mutalib, Abdul [National Nuclear Energy Agency of Indonesia (BATAN), Tangerang (Indonesia); Chakrov, Petr [Institute of Nuclear Physics, National Nuclear Center of Republic of Kazakhstan (INP-NNC-RK), Almaty (Kazakhstan)

    2012-03-15

    Technetium-99m ({sup 99m}Tc) is one of the most commonly used radioisotopes in the field of nuclear medicine. As one of effective uses of the JMTR, JAEA has a plan to produce {sup 99}Mo by (n, {gamma}) method, a parent nuclide of {sup 99m}Tc. JAEA has performed R and D on production method of {sup 99}Mo-{sup 99m}Tc in JMTR cooperating with foreign organizations and relevant Japanese enterprises under the cooperation programs. In this paper, present status of R and D for production of {sup 99}Mo-{sup 99m}Tc in JMTR under international cooperation is introduced and constructions of the irradiation and PIE facilities at the JMTR site are also described. (author)

  14. Technetium-99m labeling and fibronectin binding ability of Corynebacterium diphtheriae; Marcacao de Corynebacterium diphtheriae com Tecnecio-99m e avaliacao da capacidade de ligacao a fibronectina de plasma humano

    Energy Technology Data Exchange (ETDEWEB)

    Souza, S.M.S.; Nagao, P.E.; Bernardo-Filho, M. [Universidade do Estado do Rio de Janeiro, RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes; Pereira, G.A.; Napoleao, F.; Andrade, A.F.B.; Hirata Junior, R.; Mattos-Guaraldi, A.L. [Universidade do Estado do Rio de Janeiro, RJ (Brazil). Faculdade de Ciencias Medicas

    2004-04-15

    The use of radionuclides has permitted advances in areas of clinical and scientific knowledge. Several molecules and cells have been labelled with Technetium-99m ({sup 99m}Tc). The stannous chloride (SnCl{sub 2}) has a significant influence on the labeling and stability of {sup 99m}Tc radiotracers. The frequent risk of diphtheria epidemics has intensified interest in the virulence factors of Corynebacterium diphtheriae. Although studies have looked at potential adhesins including haemagglutinins and exposed sugar residues, the molecular basis of mechanisms of adherence remains unclear. Adherence of pathogens to mammalian tissues may be mediated by fibronectin (FN) found in body fluids, matrix of connective tissues, and cell surfaces. In the present study we evaluated the binding ability to human plasma FN by {sup 99m}Tc labeled-C.diphtheriae. Due to adverse effects of stannous ions, microorganisms were submitted to survival and filamentation induction assays. Data showed a dose dependent susceptibility to SnCl{sub 2} bactericidal effects. Cell filamentation was observed for concentrations of SnCl{sub 2} > 110 {mu}g/ml. Adherence levels of {sup 99m}Tc labelled 241strain to coverslips coated with 20 {mu}g/ml FN were higher (P = 0.0037) than coated with bovine serum albumin. FN binding by the sucrose fermenting 241 C. diphtheriae strain (8.9% + 2.6) was significantly lower (P=0.0139) than Staphylococcus aureus Cowan I strain (34.1% {+-} 1.2). Therefore, bacterial {sup 99m}Tc labeling represents an additional tool that may contribute to the comprehension of C. diphtheriae interactions with host receptors such as FN that act as biological organizers by holding bacterial cells in position and guiding their migration. (author)

  15. Prognostic value of technetium-99m-labeled single-photon emission computerized tomography in the follow-up of patients after their first myocardial revascularization surgery

    Directory of Open Access Journals (Sweden)

    Márcia Maria Sales dos Santos

    2003-01-01

    Full Text Available OBJECTIVE: To assess the prognostic value of Technetium-99m-labeled single-photon emission computerized tomography (SPECT in the follow-up of patients who had undergone their first myocardial revascularization. METHODS: We carried out a retrospective study of 280 revascularized patients undergoing myocardial scintigraphy under stress (exercise or pharmacological stress with dipyridamole and at rest according to a 2-day protocol. A set of clinical, stress electrocardiographic and scintigraphic variables was assessed. Cardiac events were classified as "major" (death, infarction, unstable angina and "any" (major event or coronary angioplasty or new myocardial revascularization surgery. RESULTS: Thirty-six major events occurred as follows: 3 deaths, 11 infarctions, and 22 unstable anginas. In regard to any event, 22 angioplasties and 7 new surgeries occurred in addition to major events, resulting a total of 65 events. The sensitivity of scintigraphy in prognosticating a major event or any event was, respectively, 55% and 58%, showing a negative predictive value of 90% and 83%, respectively. Diabetes mellitus, inconclusive stress electrocardiography, and a scintigraphic visualization of left ventricular enlargement were significant variables for the occurrence of a major event. On multivariate analysis, abnormal myocardial scintigraphy was a predictor of any event. CONCLUSION: Myocardial perfusion tomography with Technetium-99m may be used to identify high-risk patients after their first myocardial revascularization surgery.

  16. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  17. sup 99m Tc-sucralfate scintigraphy in inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, P.B.; Lech, Y.; Moeller-Petersen, J.; Vilien, M.; Fallingborg, J. (Aalborg Sygehus (Denmark)); Ekelund, S. (Copenhagen County Hospital (Denmark))

    1989-01-01

    Technetium-99m-labelled albumin-sucralfate was orally administered to 11 patients (Crohn's disease, 8; ulcerative colitis, 3) and 3 healthy volunteers. Serial scintigraphy was performed, and scintigraphic interpretations were compared with radiographic end endoscopic findings in an open study. It was not possible in any patient to relate the scintigraphic findings to the localizations of inflammatory bowel disease, nor was it possible to distinguish the scans in the patients from the scans of the healthy volunteers. It is concluded the {sup 99m}Tc-albumin-sucralfate scintigraphy is of no value in the detection of inflammatory bowel disease. 8 refs.

  18. Techneticum-99m pharmaceuticals. Preparation and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Zolle, I.

    2007-01-01

    Radioactive drug development is a multi-disciplinary task, therefore, in a concerted effort, dedicated scientists and experts from different fields of specialisation have contributed to this book. It is presented in two sections. Section 1 contains basic principles and methods used for analysis, information on the chemistry of technetium and on radiopharmaceuticals labelled with technetium-99m, the characteristics of the 99 Mo/99mTc-generator, of 'kits' and formulations for in-vitro labelling, and special safety aspects for in-vivo labelling of blood cells. Section 2 contains monographs of 99mTc-radiopharmaceuticals used in nuclear medicine. Each monograph includes information on the chemistry, formulation, commercial products and trade names, factors affecting in-vivo performance, clinical information on pharmacokinetics, as well as details concerning the clinical application and the radiation dose to patients. (orig.)

  19. Technetium Behavior and Recovery in Soil

    Energy Technology Data Exchange (ETDEWEB)

    Meinken,G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated soils.

  20. Technetium behavior and recovery in soil

    International Nuclear Information System (INIS)

    Meinken, G.E.

    1995-12-01

    Technetium-99 in soils is of great concern because of its long half-life and because it can not be detected readily. This work reviews the behavior of technetium in various types of soils. A method for extracting technetium from soil was developed with the use of technetium-95m and 99m to determine recoveries at each step. Technetium chemistry is very complicated and problem areas in the behavior and recovery have been highlighted. Technetium is widely used in nuclear medicine and a review of its chemistry pertaining to radiopharmaceuticals is relevant and helpful in environmental studies. The technetium behavior in the patented citric acid method for the removal of toxic metals in contaminated soils was studied. An innovative method using solid phase extraction media for the concentration of technetium extracted from soils, with water and hydrogen peroxide, was developed. This technique may have a useful environmental application for this type of remediation of technetium from contaminated