WorldWideScience

Sample records for tc-99m dtpa comparison

  1. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  2. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  3. 99mTc-MAG3: can it be a viable alternative to 99mTc-DTPA ?

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Nair, R.; Gopinath, P.G.

    1991-01-01

    The purpose of this study was to assess the potentials of 99m Tc MAG 3 to replace universally used 99m Tc-DTPA as a routine renal agent. Five patients with different nephrological problems were first studied with 99m Tc MAG 3 and then reinvestigated with 99m Tc-DTPA two to seven days later. Renal MAG 3 gamma camera images were found to be almost identical with those of 99m Tc-DTPA images except high hepatic and splenic uptake of the former compound in four out of five patients (80%) irrespective of kidney function. MAG 3 and DTPA renograms showed identical differential renal uptake function (r=0.87) with slightly higher uptake in right kidneys. Time to reach the peak correlated well (r=0.91). Time to reach half maximum renal activity was also found to be almost identical (r=0.97) for MAG 3 and DTPA. It was felt that the age old 99m Tc-DTPA is as good a compound as 99m Tc MAG 3 with regard to imaging and assessment of renal uptake, drainage and differential renal functions. 99m Tc-DTPA is much cheaper, readily available in India and stable to suit the logistics in a busy nuclear medicine department for routine renography. (author). 10 refs., 2 figs., 3 tabs

  4. Ventilation scintigraphy of the lung with sup(99m)Tc-DTPA or with sup(99m)Tc-sulfur colloid

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, D; Matthys, H; Coates, G; Dolovich, M; Newhouse, M

    1983-04-01

    Ventilation scintigraphy of the lung, obtained with sufficiently small sup(99m)Tc-labelled aerosol particles, provides an image of ventilation distribution that is acceptable in clinical routine. Whether sup(99m)Tc-DTPA or sup(99m)Tc-sulfur colloid is more suitable as a carrier was studied in 6 smokers and 8 non-smokers with chronic obstructive pulmonary disease. sup(99m)Tc-sulfur colloid was not absorbed by the bronchial mucosa and therefore appears to be an almost ideal agent. In contrast, sup(99m)Tc-DTPA was absorbed by the bronchial mucosa in all smoking patients more rapidly and inhomogenously than in non-smokers. The quantitative and qualitative comparison of the two dorsal ventilation scans taken both immediately after inhalation and 20 min later, showed in all 6 smoking patients after 20 min significant differences which influenced the diagnostic result. sup(99m)Tc-DTPA is therefore not recommended for use in ventilation lung scintigraphy, especially in smoking patients.

  5. 99mTc-EDTA and 99mTc-DTPA complexes as hydrological tracers

    International Nuclear Information System (INIS)

    Dominguez, J.; Borroto, J.; Nazco, J.; Perez, E.; Gamboa, R.; Cruz, J.

    2002-01-01

    The [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1- were evaluated as radiotracers for short time hydrological studies. Their complex stability after labelling with 9.25 GBq of 99m Tc, the behaviour against pH variations, from 5 to 9, in simulated solutions and in natural river waters and the sorption of these compounds on the river sediments, were tested in laboratory experiments. Finally field double tracing experiments were carried out for each of labelling complexes and Rhodamine WT. From recovery calculations not losses of the 99m Tc activity were observed. The shape of the RTD curves of the [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1 were quite similar to the Rhodamine Wt ones. May be concluded that both complexes behaved conservatively on the studied environmental conditions. (author)

  6. Evaluation of the absorbed dose to the kidneys due to Tc99m (DTPA) / Tc99m (Mag3) and Tc99m (Dmsa)

    International Nuclear Information System (INIS)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P.; Idrogo C, J.; Marquez P, F.

    2015-10-01

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc 99m (DTPA) / Tc 99m (Mag3) or Tc 99m (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc 99m (DTPA) / Tc 99m (Mag3), are given by 0.00466 mGy.MBq -1 / 0.00339 mGy.MBq -1 . Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc 99m (DTPA) / Tc 99m (Mag3). The absorbed dose to the kidneys due to Tc 99m (Dmsa) is 0.17881 mGy.MBq -1 . Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc 99m (Dmsa). (Author)

  7. Clinical application of 99mTc-DTPA-HSA

    International Nuclear Information System (INIS)

    Kawamura, Yasuaki; Yamazaki, Junichi; Okuzumi, Ichio

    1989-01-01

    A newly developed blood pool imaging agent, Tc-99m DTPA-HSA (Tc-99m HSA-D), was clinically assessed in blood pool studies of patients with heart disease. Twenty mCi of Tc-99m HSA-D was iv injected to the patients. Similarly, conventional Tc-99m HSA was injected one week later for comparison. Blood counts of Tc-99m HSA-D were significantly higher than those of Tc-99m HSA at 30 minutes after iv injection (p<0.01) and at one, 3, and 6 hours (p<0.001). For the heart, liver, and lungs, sequential counts of Tc-99m HSA-D were also significantly higher than those of Tc-99m HSA. Free Tc-99m uptake in the stomach, thyroid gland, and kidneys was higher on Tc-99m HSA images than Tc-99m HSA-D images. Hepatic and pulmonary uptake of free Tc-99m that were visualized on Tc-99m HSA-D did not influence the diagnostic ability. None of the patients had clinical toxicity of Tc-99m HSA-D. The results indicate that Tc-99m HSA-D is a stable blood pool imaging agent. (Namekawa, K)

  8. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  9. Evaluation of fibrinogen-DTPA-99mTc. Biodistribution and imaging studies

    International Nuclear Information System (INIS)

    Lungu, V.; Mihailescu, G.; Fugaru, V.; Preda, A.

    1998-01-01

    Labelling with 99m Tc of fibrinogen, using DTPA anhydride as the bifunctional chelating agent, was studied in animals with venous thrombi. The parameters studied were: i) coupled reaction of 99m Tc with the fibrinogen-DTPA-Sn(II) in lyophilised form; ii) biodistribution studies of fibrinogen- 99m Tc in animals with venous thrombi, and iii) imaging studies by scintigraphic methods. The present study showed that the radiochemical purity of fibrinogen-DTPA- 99m Tc is > 95% for a maximum of 5 mCi (185 MBq) radioactivity of 99m Tc in the 1.5-2 ml volume. Above this level of radioactivity we found a drastic decrease in the radiochemical purity. The radioactivity ratio of the venous thrombi to the blood was 2.32+-0.45. The scintigraphic images showed a significant accumulation of fibrinogen-DTPA- 99m Tc in 1-hour-old thrombi, 1 hour after injection. From this results the diagnostic potential of fibrinogen-DTPA-Sn(II) in kit form was evaluated. (author)

  10. Accumulation of sup 99m Tc-DTPA in neurofibroma of Recklinghausen disease

    Energy Technology Data Exchange (ETDEWEB)

    Funasaki, Hiroki; Tomita, Yasuji; Kondo, Hidemaru; Shiba, Ritsu; Honma, Genki; Sai, Shitake; Urushibara, Nobuo; Murota, Kagehisa; Kawakami, Kenji (Jikei Univ., Tokyo (Japan). School of Medicine)

    1989-07-01

    The ability of scanning with Tc-99m DTPA to detect neurofibroma in Rechlinghausen's disease was evaluated in 8 patients with confirmed neurofibroma, whose ages ranged from 10 to 58 years. They were scanned 2 hours after i.v. injection of Tc-99m DTPA (20 mCi for adults and 10 mCi for children). Tc-99m DTPA was taken up by plexiform neurofibroma in 5 patients and by pachydermatocele in 4 patients. The uptake in plexiform neurofibroma was noticeable. In one patient who had systemic multiple epidermal neurofibromas, uptake of Tc-99m DTPA was not observed. Tc-99m DTPA scanning is considered to be an extremely useful technique in localizing masses in the chest and abdomen of patients with Rechlinghausen's disease. (N.K.).

  11. Synthesis, 99m Tc-labeling, and preliminary biological evaluation of DTPA-melphalan conjugates.

    Science.gov (United States)

    Wang, Jianjun; Yang, Wenjiang; Xue, Jinquan; Zhang, Yanhua; Liu, Yu

    2017-12-01

    Melphalan (MFL) is a typical nitrogen mustard for the treatment of many types of cancer. For the purpose to develop novel 99m Tc-labeled tumor imaging agents with SPECT, MFL was directly labeled by 99m Tc using diethylene triamine pentacetate acid (DTPA) as bifunctional chelating agent. The novel ligands were successfully synthesized by conjugation of DTPA to MFL to get monosubstituted DTPA-MFL and bis-substituted DTPA-2MFL. Radiolabeling was performed in high yield to get 99m Tc-DTPA-MFL and 99m Tc-DTPA-2MFL, respectively, which were hydrophilic and stable at room temperature. The high initial tumor uptake with retention, good tumor/muscle ratios, and satisfactory scintigraphic images suggested the potential of 99m Tc-DTPA-MFL and 99m Tc-DTPA-2MFL for tumor imaging. However, the slow normal tissue clearance would be a great obstacle. Further modification on the linker and/or 99m Tc-chelate to improve the tumor targeting efficacy and in vivo kinetic profiles is currently in progress. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Pulmonary clearance of 99mTc-DTPA and 99mTc-albumin in rabbits with surfactant dysfunction and lung injury

    International Nuclear Information System (INIS)

    Nilsson, K.; Wollmer, P.

    1992-01-01

    We measured the pulmonary clearance of inhaled 99m Tc-DTPA and 99m Tc-albumin in rabbits with surfacant dysfunction induced by dioctyl sodium sulphosuccinate and in rabbits with lung injury induced by oleic acid. After inhalation of 99m Tc-albumin in ten animals, clearance of the tracer from the lungs was monitored for 90 min. The first 30 min was a control period. Dioctyl sodium sulphosuccinate was then administered in aerosol and after another 30 min oleic acid was injected intravenously. Ten other rabbits were given 99m Tc-DTPA, and clearance was externally recorded for 60 min. Five animals inhaled detergent aerosol and five animals were given oleic acid intravenously after 30 min. Airway pressures, tidal volume, and arterial blood gases were measured before and after each intervention. The half-life of 99m Tc-albumin in the lung was 442 ± 123 min during the control period, 363 ± 52 min after detergent administration, and 134 ± 18 min after oleic acid administration. The half-life of 99m Tc-DTPA was 94 ± 16 min before and 10 ± 0.6 min after detergent administration and 75 ± 12 min before and 18 ± 1.8 min after oleic acid administration. Gas exchange was not affected by administration of dioctyl sodium sulphosuccinate but markedly impaired after injection of oleic acid. Compliance of the respiratory system remained unaffected by detergent but decreased after injection of oleic acid. The results indicate that the rate limiting factors for the alveolo-capillary transfer of 99m Tc-albumin and 99m Tc-DTPA are different. Surfactant dysfunction affects the transfer of 99m Tc-DTPA but not 99m Tc-albumin. (author)

  13. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    International Nuclear Information System (INIS)

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-01-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure

  14. Tc-99m DTPA and Tc-99m DMSA renal scan findings in patients with congenital megacalyces and megaureter without urinary tract obstruction

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Jin Ho; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2003-01-01

    A 10 days old male infant with congenital megacalyces and megaureter, diagnosed by prenatal ultrasonographic screening, underwent Tc-99m DTPA renal scan for evaluation of urinary tract patency, Tc-99m DMSA scan for evaluation of renal cortical damage. He also underwent intravenous urography(IVU) and renal ultrasonography. Tc-99m DTPA renal scan demonstrates intense tracer accumulation in enlarged both renal pelvocalyses and ureters, which rapidly washout diuretics administration. Tc-99m DMSA renal cortical scan shows no remarkable photon defect in both renal cortices and visible tracer uptake in both megaureter areas. Ultasonographic and IVU studies show enlarged both renal calyses and bullously dilated ureters, but no dilatation in renal pelvis. Follow up Tc-99m DTPA renal scan, performed at one year later, also reveals intense tracer accumulation in enlarged both urinary tracts which rapidly washout without diuretics, and shows no significant change compare to the previous Tc-99m DTPA renal scan. Urinary tract obstruction and renal cortical damage can be easily evaluated with Tc-99m DTPA and Tc-99m DMSA scans in patients with megacalyces and megaureter

  15. Tc-99m DTPA and Tc-99m DMSA renal scan findings in patients with congenital megacalyces and megaureter without urinary tract obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Bae, Jin Ho; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo [Kyungpook National University Medical School, Daegu (Korea, Republic of)

    2003-06-01

    A 10 days old male infant with congenital megacalyces and megaureter, diagnosed by prenatal ultrasonographic screening, underwent Tc-99m DTPA renal scan for evaluation of urinary tract patency, Tc-99m DMSA scan for evaluation of renal cortical damage. He also underwent intravenous urography(IVU) and renal ultrasonography. Tc-99m DTPA renal scan demonstrates intense tracer accumulation in enlarged both renal pelvocalyses and ureters, which rapidly washout diuretics administration. Tc-99m DMSA renal cortical scan shows no remarkable photon defect in both renal cortices and visible tracer uptake in both megaureter areas. Ultasonographic and IVU studies show enlarged both renal calyses and bullously dilated ureters, but no dilatation in renal pelvis. Follow up Tc-99m DTPA renal scan, performed at one year later, also reveals intense tracer accumulation in enlarged both urinary tracts which rapidly washout without diuretics, and shows no significant change compare to the previous Tc-99m DTPA renal scan. Urinary tract obstruction and renal cortical damage can be easily evaluated with Tc-99m DTPA and Tc-99m DMSA scans in patients with megacalyces and megaureter.

  16. Development of Tc-99m-DTPA-HSA as a new blood pool scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Shirakami, Y; Matsumoto, Y; Yamauchi, Y; Kurami, M; Ueda, N; Hazue, M

    1987-04-01

    A new HSA preparation, Tc-99m-DTPA-HSA, was developed as a blood pool scanning agent. It shows higher labeling yield (more than 95 %) and higher blood retention (74.7 % I.D. at 1 hour post-injection) than Tc-99m-HSA prepared by directly labeling of HSA with Tc-99m. The introduction of DTPA, a strong bifunctional chelating agent, to HSA provides sites for the stable binding of Tc-99m. The preparation composed of 20 mCi of Tc-99m at calibration time and 10 mg of DTPA-HSA in a vial. After labeling, it had been stable for 24 hours at room temperature. In rats, most of Tc-99m-DTPA-HSA injected was metabolized and excreted in urine and feces. The cumulative radioactivity in urine and feces were 56.0 % and 13.7 % of injected dose, respectively, at 48 hours after injection. Metabolites observed in urine were Tc-99m-urea, Tc-99m-DTPA, reduced Tc-99m and so on. Tc-99m-DTPA-HSA proved, thus, a desirable feature for the blood pool scanning agent.

  17. Estimating GFR in children with 99mTc-DTPA renography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Møller, Michael L; Pfeifer, Andreas K

    2010-01-01

    study was to evaluate the accuracy of this non-invasive method in children. We calculated GFR from (99m)Tc-diethylene triamine pentaacetic acid (DTPA) renography and compared with (51)Cr-EDTA plasma clearance of 29 children between the age of 1 month and 12 years (mean 4.7 years). The correlation...... between (99m)Tc-DTPA renography and (51)Cr-EDTA plasma clearance was for all children R = 0.96 (n = 29, PTc-DTPA renography is reliable...

  18. Quantitation of cerebral blood volume by 99mTc-DTPA-HSA SPECT

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Machida, Kikuo; Momose, Toshimitsu

    1992-01-01

    The characteristics of technetium-99m diethylenetriaminepentaacetic acid human serum albumin ( 99m Tc-DTPA-HSA) as an agent for quantitation of cerebral blood volume (CBV) were examined. The radioactivity after decay correction as a percentage of the activity at 10 minutes was 84.3±1.3% at 120 minutes after the injection of 99m Tc-DTPA-HSA. Radioactivity was found exclusively in plasma, with little in blood cells. The blood retention of 99m Tc-DTPA-HSA is sufficient, and its use in the quantitation of CBV omits the need for centrifugation of the blood sample. CBV quantified using the tracer and a SPECT system with a single-head rotating gamma camera was 4.09±0.60 ml/100g brain, similar to values reported previously. Two serial SPECT scans provided similar images, and the CBV values determined by the two scans were closely correlated (p 99m Tc-DTPA-HSA has useful properties for quantitative CBV measurement and that quantitation of CBV by 99m Tc-DTPA-HSA SPECT is feasible using a system with a single-head rotating gamma camera. (author)

  19. Development and biodistrubition modeling of 99mTc-DTPA

    Directory of Open Access Journals (Sweden)

    Mohammed Bricha

    2015-09-01

    Full Text Available Purpose: In this study, the team modeled the biodistribution and the efficiency of two 99m-technetium diethylene triamine penta acetate (99mTc-DTPA based radiopharmaceuticals.Methods: The first radiopharmaceutical (DTPA-CNESTEN is developed at the laboratories of the radiopharmaceutical production unit of the National Center for Nuclear Energy, Sciences and Technologies (CNESTEN-Morocco, and the second one is the commercial DTPA (DTPA-ref. Freeze-dried kits were successfully radiolabeled (radiochemical purity >95% with the 99m Tc. Then drugs were injected to male BALB/c mice. In each 2 min, 5 min, 15 min, 1 h and 2 h time points after injections we evaluate tissue’s distributions characteristics. At the end, an automatic modeling of the data were recorded from thyroid, blood and urinary excretion kinetics and biodistribution in mice using both DTPA kits. The study aimed to extract the parameters of the function used to fit the recorded data. Results and Conclusion: the team concluded that the biodistribution of 99mTc-DTPA can be modeled using a combination of two exponential parts. Moreover, the resultant plots showed that there is strong correlation between the formula found in literature and the one derived on the basis of the fit of data sets in this study. In addition, it was found that the biodistribution behaviors of the developed kit and the commercial one were very close. The obtained results suggest that the developed DTPA has practically the same kinetics as the commercial one.

  20. Tumor VEGF-R2 imaging with Tc-99m DTPA-dextran-DC101

    International Nuclear Information System (INIS)

    Kim, E. M.; Jeong, H. J.; Kim, S. L.; Jeong, S. J.; Lee, C. M.; Kim, D. W.; Lim, S. T.; Sohn, M. H.

    2007-01-01

    Vascular endothelial growth factor (VEGF) and its receptor (fetal liver kinase 1/kinase insert domain-containing receptor) play an important role in vascular permeability and tumor angiogenesis. Here, we investigated the Tc-99m DC101-dextran for VEGF-R2 imaging in tumor xenografted mice. DTPA conjugated amino-dextran was synthesized and then this was reacted with sulfo-LC-SPDP. Synthesis was identified by 1H-NMR. DTPA-dextran-SPDP was reacted with DC101. Binding affinity was checked by ELISA assay. Female athymic nude mice bearing B16F10 tumors were each injected via the tail vein with about 18.5 MBq of the Tc-99m DTPA-dextran-DC101, Tc-99m DTPA-DC101 and I-131 DC101. Biodistribution was performed at 1, 6, and 24h. DTPA-dextran-DC101 bind to FLK-1 in a dose-dependent manner. And this was blocked by significantly by free DC101. Labeling efficiency was approximately above 99% at 24 hr. Tc-99m DTPA-DC101 and I-131 DC101 showed rapid liver uptake, whereas Tc-99m DTPA-dextran-DC101 weak liver uptake and kidney elimination. In biodistribution results, Tc-99m DTPA-dextran-DC101 showed rapid renal clearance, and increased tumor uptake according to the time. Conjugation of antibody with dextran polymer is responsible for the decreased liver uptake and increased tumor uptake

  1. Sidestream smoke inhalation decreases respiratory clearance of 99mTc-DTPA acutely

    International Nuclear Information System (INIS)

    Yates, D.H.; Havill, K.; Thompson, M.M.; Rittano, A.B.; Chu, J.; Glanville, A.R.

    1996-01-01

    The permeability of the alveolar-capillary barrier to an inhaled aerosol of technetium 99m labelled diethylenetriamine penta-acetate ( 99m Tc-DTPA is used as an index of alveolar epithelial injury. Permeability is greatly increased in active smokers. The aim of this study was to determine the effect of sidestream smoke inhalation on permeability as this has not been described previously. Lung clearance of inhaled 99m Tc-DTPA aerosol was measured in 20 normal non-smoking subjects before and after exposure to one hours sidestream smoke inhalation. Measured carbon monoxide (CO) levels rose to a maximum of 23.5 ±6.2 ppm from baseline values of 0.6±1.3 (p 99m Tc-DTPA clearance rose from baseline 69.1± 15.6 (mean ± to 77.4 ±17.8) after smoke exposure. No effect of 99m Tc-DTPA scanning of sidestream smoke was demonstrated on lung function. It was concluded that low level sidestream smoke inhalation decreases 99m Tc-DTPA clearance acutely in humans. The mechanism of this unexpected result is not established but may include differences in constituents between sidestream and mainstream smoke, alterations in pulmonary microvascular blood flow, or changes in surfactant due to an acute phase irritant response. 34 refs., 2 figs

  2. Tl-201 and Tc-99m-DTPA neuro-SPECT in cerebral radiation necrosis

    International Nuclear Information System (INIS)

    Cleto, E.M. Jr.; Holmes, R.A.; Gumerlock, M.K.; Cabeen, M.; Logan, K.W.; Hoffman, T.J.

    1992-01-01

    The results in 3 cases of radiation necrosis demonstrate that by using both radionuclides Tl-201 and Tc-99m-DTPA, one can provide a semi-quantitative method to differentiate recurrent tumor from radiation necrosis. Focally increased cerebral Tl-201 activity in irradiated brain tumor patients is not specific for tumor recurrence, but when used in combination with DTPA, one is able to estimate the amount of Tl-201 activity resulting from increased blood-brain barrier permeability. If the average Tl-201 index is less than the average Tc-99m-DTPA index it suggests that the increased Tl-201 activity results primarily from blood-brain barrier breakdown. Tc-99m-DTPA SPECT, in addition to Tl-201 SPECT, or serial Tl-201 SPECT imaging may increase the accuracy of brain scintigraphy in differentiating radiation necrosis from tumor recurrence. To verify these preliminary findings, we are in the process of analyzing additional SPECT data on 9 more patients with malignant brain tumors. Using a slightly different method of quantifying Tl- 201/Tc-99m-DTPA ratios (computing the ratio of intralesional Tl-201 or Tc-99m-DTPA activity compared to adjacent scalp activity), patients with tumor recurrence have higher Tl-201/Tc-99m-DTPA ratios compared to those with radiation necrosis (verbal communication with Dr. Mary K. Gumerlock). (orig.) [de

  3. Attachment of 99mTc to lipid vesicles containing the lipophilic chelate dipalmitoylphosphatidylethanolamine-DTPA

    International Nuclear Information System (INIS)

    Ahkong, Q.F.; Tilcock, C.

    1992-01-01

    The binding of 99m Tc to negatively-charged and neutral unilamellar lipid vesicles was investigated in the absence and presence of the ligand diethylenetriaminepentaacetic acid (DTPA) covalently attached to the headgroup of phosphatidylethanolamine at the surface of the membrane. Even in the absence of DTPA on the membrane surface, 99m Tc reduced by Sn bound to the membrane surface but rapidly dissociated from the vesicles in the presence of plasma in vitro. When DTPA was present on the membrane surface, dissociation of 99m Tc from the vesicle surface in plasma was much reduced. The dissociation of 99m Tc from the surface of negatively-charged vesicles was less than for neutral vesicles in the absence of ligand but was markedly greater than for vesicles containing the ligand DTPA, suggesting that the binding of 99m Tc to vesicles with surface-attached DTPA could not be explained solely on the basis of the negative charge provided by the DTPA. In vitro experiments using 14 C-labeled lipids as well as in vivo imaging studies indicated that dissociation of 99m Tc from the surface of the vesicle did not arise predominantly because of lipid exchange with plasma components or due to cleavage of Tc-DTPA from the vesicle surface. For vesicles with surface-attached DTPA, 99m Tc dissociation from the vesicle surface in plasma was further reduced by addition of the antioxidant ascorbate. (author)

  4. Breast-milk radioactivity after a Tc-99m DTPA aerosol/Tc-99m MAA lung study

    International Nuclear Information System (INIS)

    Mountford, P.J.; Hall, F.M.; Wells, C.P.; Coakley, A.J.

    1984-01-01

    Measurements were made of the concentration of Tc-99m activity in samples of breast milk following an administration of Tc-99m DTPA aerosol for a lung ventilation image and one of Tc-99m MAA for lung perfusion. The activity was 222 nCi/ml of milk (8.2 kBq/ml) at 2 hr after the MAA injection, and it was found to be excreted exponentially with an effective half-life of 4.6 hr. There was a small incorporation of Tc-99m into breast-milk protein. The authors conclude that the combined use of these two Tc-99m agents did not indicate the interruption of breast feeding beyond 24 hr after administration of the MAA, and that for an aerosol ventiliation study alone, breast feeding need not be interrupted for more than 4 hr after the test

  5. Comparative evaluation of 131I-hippuran and sup(99m)Tc-DTPA for renal function test

    International Nuclear Information System (INIS)

    Kempi, V.; Persson, R.B.R.; Svensson, L.

    1975-07-01

    131 I-labelled Hippuran and sup(99m)Tc-labelled DTPA have been compared as substances used for renal function tests. The radiation absorbed dose for 131 I-Hippuran and sup(99m)Tc-DTPA to different organs of an adult standard man is given i a table, showing considerably lower doses for sup(99m)Tc-DTPA. Good agreement was found between the renographic curves obtained with 131 I-Hippuran and sup(99m)Tc-DTPA compared to 131 I-Hippuran excellent scintiphotos of the kidney and also of the upper urinary ways were obtained with sup(99m)Tc-DTPA. With sup(99m)Tc-DTPA, repeated examinations make it possible to follow the development of a disease without great radiation risk to the patient (K.K.)

  6. Measurement of pulmonary epithelial permeability with /sup 99m/Tc-DTPA aerosol

    International Nuclear Information System (INIS)

    Coates, G.; O'Brodovich, H.

    1986-01-01

    The rate at which inhaled aerosol of /sup 99m/Tc-diethylenetriamine pentaacetate (DTPA) leaves the lung by diffusion into the vascular space can be measured with a gamma camera or simple probe. In normal humans, /sup 99m/Tc-DTPA clears from the lung with a half time of about 80 minutes. Many acute and chronic conditions that alter the integrity of the pulmonary epithelium cause an increased clearance rate. Thus cigarette smoking, alveolitis from a variety of causes, adult respiratory distress syndrome (ARDS), and hyaline membrane disease (HMD) in the infant have all been shown to be associated with rapid pulmonary clearance of /sup 99m/Tc-DTPA. Rapid clearance is also promoted by increased lung volume and decreased surfactant activity. Although the mechanism of increased clearance in pathological states is not known, the /sup 99m/Tc-DTPA lung-clearance technique has great potential clinically, particularly in patients at risk from ARDS and HMD and in the diagnosis and follow-up of alveolitis. 58 references

  7. On the separation of 99mTcO4-, 99mTc-DTPA and 99mTc-citrate as marker species for the determination of Tc chemical forms in plant material using capillary zone electrophoresis

    NARCIS (Netherlands)

    Krijger, G.C.; Claessens, H.A.; Wolterbeek, H.Th.

    1996-01-01

    The present paper addresses the potential use of capillary zone electrophoresis (CZE) as an anal. tool in 99Tc speciation studies. To optimize sampling, storage and anal. procedures, the three marker compds. 99mTcO4-, 99mTc-DTPA and 99mTc-citrate were synthesized and used in test-measurements with

  8. Comparison of peritoneal equilibration test(PET) with Tc99m-DTPA excretion in the assessment of peritoneal permeability

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Jeloka, T.K.; Nagabhushan, S.; Sharma, R.K.

    2002-01-01

    Aim: Assessment of peritoneal permeability is necessary for successful management of End Stage Renal Disease (ESRD) patients by Continuous Ambulatory Peritoneal Dialysis (CAPD). Twardowski in 1987 described for the first time a method know as Peritoneal Equilibration Test (PET ) to determine peritoneal membrane characteristics. However, this test is not only cumbersome but is associated with several limitations. The objective of this study was to develop an alternative method of assessing the peritoneal permeability and compare this method with the conventional PET. Method: Twenty patients under going regular CAPD were included in this study. Before starting the peritoneal dialysis 370 MBq (10 mCi) 99mTc-DTPA was injected intravenously in the same standard precondition as for PET evaluation. A standard dose of same quantity was kept and used later for calculations. At the end of four hours a dialysate fluid sample (1 ml) was collected and the total dialysis effluent fluid volume was measured. Excretion of 99mTc-DTPA into the dialysate fluid as percentage of injected dose was calculated. Simultaneously standard PET values were recorded for comparison. Results: Peritoneal excretion of 99mTc-DTPA ranged from 8 % to 16 % of the injected dose depending upon the peritoneal membrane permeability. Depending upon the DTPA excretion the patients were divided into 4 groups: High Transporter (15% and above; High Average (12 to 15 %); Low Average (10 to 12%); Low Average (10% and less). When the results were compared with the conventional PET values, a good correlation (r=0.79) could be found. Conclusion: Determining the excretion of 99mTc-DTPA in the dialysate fluid after 4 hrs as percentage of the injected dose is a simple and convenient method to assess the peritoneal membrane permeability and can be used as an alternative technique to conventional PET which is very cumbersome and associated with many limitations

  9. Are commercial 99m Tc-DTPA preparations reliable for quantitation of renal function

    International Nuclear Information System (INIS)

    Jeghers, O.; Kinthaert, J.; Georges, B.; Van Gansbeke, B.; Piepsz, A.; Ham, H.R.

    1983-01-01

    Bad labeling and stability of 99m-Tc-DTPA preparations were found on several occasions, resulting in important artefacts in quantitative renal studies. Further studies are needed in order to understand the origin of these inconstant findings. Repeated quality control on Tc-99m-DTPA preparations are mandatory

  10. Comparison of peritoneal equilibration test with 99mTc-DTPA excretion in the assessment of peritoneal permeability

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Nagabhushan, S.; Jeloka, T.K.; Sharma, R.K.

    2004-01-01

    Assessment of peritoneal permeability is necessary for successful management of end-stage renal disease (ESRD) patients by continuous ambulatory peritoneal dialysis (CAPD). The objective of this study was to develop an alternative method of assessing the peritoneal permeability and to compare this method with the conventional method, the peritoneal equilibrium test, first described by Twardowski in 1987. Twenty patients undergoing regular CAPD were included in this study. Before starting the peritoneal dialysis, 370 MBq (10 mCi) technetium-99m diethylene triamine penta-acetic acid ( 99m Tc-DTPA) was injected intravenously. A standard dose of the same quantity was kept and used later for calculations. At the end of 4 h, a dialysate fluid sample (1 ml) was collected and the total dialysis effluent fluid volume was measured. Excretion of 99m Tc-DTPA into the dialysate fluid as a percentage of the injected dose was calculated. Simultaneously, standard peritoneal equilibrium test values were recorded for comparison. Peritoneal excretion of 99m Tc-DTPA ranged from 8% to 25% of the injected dose, depending on the peritoneal membrane permeability. When the results were compared with the conventional method, a good correlation (r=0.79) was found. This innovative radionuclide technique is a simple and convenient method to assess the peritoneal membrane permeability and can be used as an alternative to the peritoneal equilibrium test, which is very cumbersome and associated with many limitations. (orig.)

  11. Comparison of the biodistribution of gadolinium-153 DTPA and technetium-99m DTPA in rats

    International Nuclear Information System (INIS)

    Prato, F.S.; Wisenberg, G.; Marshall, T.P.; Uksik, P.; Zabel, P.

    1988-01-01

    Twenty-three mature Sprague-Dawley male and female rats were simultaneously injected with trace quantities of [153Gd]DTPA and [99mTc]DTPA and 0.5 mmol/kg of nonradioactive gadolinium DTPA. Rats were killed at 1 min, 5 min, 10 min, 15 min, and 30 min after the intracardiac bolus injection. The heart, lungs, liver, brain, kidney, and blood were excised and counted in a well-counter to determine the amount of the injected material in each organ and blood. In order for the percent of total injected activity to be determined, a technique was developed which allowed discrimination of the 140 keV gamma-ray of 99mTc from sum peaks of 153Gd when the latter is counted in a well-counter with 4 pi geometry. Although the distribution of the two DTPA compounds was qualitatively similar, statistical analysis indicated that the amount of 99mTc deposited in the lungs was higher than 153Gd (p = 0.03), the amount of 99mTc deposited in the kidneys was lower than 153Gd (p = 0.0004) and the amount of 99mTc in the blood was higher than 153Gd (p = 0.0022). This may be due to the greater binding of [99mTc]DTPA or its minor impurities to plasma proteins

  12. Study of the properties of sup(99m)Tc-DTPA-ferroascorbinate and sup(99m)Tc-dextrose as radiopharmaceuticals for renal scintiscanning

    International Nuclear Information System (INIS)

    Salambashev, L.; Konstantinov, P.; Ketskarova, S.; Kovacheva, S.; Babeva, S.

    1979-01-01

    Description is made of an own method for labelling of the complex DTPA-ferroascorbinate and dextrose with sup(99m)Tc for the purpose of renal scintiscanning. Experimental investigations on rabbits were carried out, and afterwards conventional scintiscanning and follow-up of the intake into the renal parenchyma by means of gamma camera were performed on 15 patients. The observations revealed that sup(99m)Tc-DTPA-ferroascorbinate was more rapidly excreted (40 min to 2 h following the intravenous administration). For this reason it is more convenient for gamma camera examination, while sup(99m)Tc-dextrose is fixing more lastingly in the parenchyma and respons to all requirements with respect to radiopharmaceuticals for conventional renal scintiscanning. (author)

  13. Comparison of inulin, iothalamate, and /sup 99m/Tc-DTPA for measurement of glomerular filtration rate

    International Nuclear Information System (INIS)

    Barbour, G.L.; Crumb, C.K.; Boyd, C.M.; Reeves, R.D.; Rastogi, S.P.; Patterson, R.M.

    1976-01-01

    Clearances of inulin, 125 I-iothalamate, and /sup 99m/Tc-Sn-DTPA were measured simultaneously in five mongrel dogs exhibiting a wide range of glomerular filtration rates (GFR). Standard constant-infusion inulin clearance was compared to radionuclide clearances after subcutaneous injection of the emitters mixed with aqueous epinephrine. All three substances were found to have virtually identical clearances. The accuracy, accessibility, low cost, low radiation hazard, and short half-life of /sup 99m/Tc-Sn-DTPA make it an excellent substance for measuring GFR. The subcutaneous technique offers an accuracy comparable to the more difficult constant-infusion method

  14. Evaluation of lung epithelial permeability in the volatile substance abuse using Tc-99m DTPA aerosol scintigraphy

    International Nuclear Information System (INIS)

    Cayir, D.; Demirel, K.; Korkmaz, M.; Koca, G.

    2011-01-01

    Chronic inhalant use is associated with significant toxic effects, including neurological, renal, hepatic, and pulmonary damage. However, there is a paucity of reports regarding respiratory complications in inhalant abusers. The aim of this study was to evaluate pulmonary epithelial permeability in the volatile substance abuse (VSA) using technetium-99m-labeled diethylenetriamine pentaacetic acid (Tc-99m DTPA) aerosol scintigraphy. This study included 18 patients with volatile substance abuse and 18 volunteer controls. All of patients and controls were smokers. Tc-99m DTPA aerosol scintigraphy was performed in all cases. Time-activity curves from each lung were generated and clearance half-time (T 1/2 ) of Tc-99m DTPA were calculated. T 1/2 of whole lung was calculated as a mean of the T 1/2 of left and right lung. The T 1/2 values of Tc-99m DTPA clearance in the substance abusers were significantly decreased as compared to the control group with respective mean values of 28.86±8.44, and 62.14±26.12 min (p=0.001). It was seen Tc-99m DTPA clearance from lung was faster as the duration of substance abuse was increased. Tc-99m DTPA pulmonary clearance is markedly accelerated in the volatile substance abuse. This suggests that inhalant abuse of substance may produce abnormalities in pulmonary alveolo-capillary membrane function. (author)

  15. Comparison between radioisotopic ventriculography in balance with Tc99-albumine-DTPA and quantitative gated SPECT with Tc-99m-MIBI for determining the eject fraction of left ventricle

    International Nuclear Information System (INIS)

    Noguera, E. C; Jaime, Adelina; Pamellin, Miriam; Veliz, J

    2002-01-01

    Radionuclide ventriculography (RNV) and electrocardiography gated myocardial perfusion single photon emission computed tomography (GSPECT), can be used to assess the ventricular function.The purpose of this study was:1) to compare left ventricular ejection fraction (LVEF(%) using post-stress or rest gated GSPECT with LVEF by resting RNV and 2) to evaluate the 99m-Tc99m human serum albumin (HAS) with diethylenetriaminepenta-acetic acid (DTPA) (99m-TcHSA-DTPA) as a potential use a as blood pool imaging agent (Au)

  16. Clinical study of renoscintiphoto using sup(99m)Tc-EDTA, -DTPA and 131I-hippuran

    International Nuclear Information System (INIS)

    Ishibashi, Akira; Ishii, Katsumi; Yoda, Kazushige; Hashimoto, Shozo

    1975-01-01

    The scintillation photographs of the kidneys of 35 cases were taken using sup(99m)Tc-EDTA. The photographs were compared with those taken using sup(99m)Tc-DTPA and 131 I-hippuran. In normal cases, sup(99m)Tc-EDTA which is excreted most slowly serves to take best the pictures of the parenchyma and the pelvis of the kidney. Being a sup(99m)Tc-labelled compound with a short half life time and being administrable at a substantial dose of 2-4mCi, sup(99m)Tc-EDTA provides an advantage to take continuous pictures of the blood vessel phase. This reagent can, therefore, help take a clear picture of the congestion site of the renal infarct. However, the renal dynamic test using EDTA or DTPA is difficult to catch such delicate changes as very slight rejection of the transplanted kidney or as very slight disturbance of the kidney parenchyma. In this respect, 131 I-hippuran is superior to EDTA and DTPA. In obstructive disorders of the kidney, there was no remarkable difference among these three reagents. (auth.)

  17. Improved measurement of the glomerular filtration rate from Tc-99m DTPA scintigraphy in patients following nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-il; Ha, Seunggyun [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University Bundang Hospital, Department of Nuclear Medicine, Seongnam-si, Gyeonggi-do (Korea, Republic of); So, Young [Konkuk University School of Medicine, Department of Nuclear Medicine, Chungju (Korea, Republic of); Lee, Won Woo [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University, Institute of Radiation Medicine, Medical Research Center, Seoul (Korea, Republic of); Seoul National University Bundang Hospital, Department of Nuclear Medicine, Seongnam-si, Gyeonggi-do (Korea, Republic of); Byun, Seok-Soo [Seoul National University College of Medicine, Department of Urology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kim, Sang Eun [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Seoul National University, Institute of Radiation Medicine, Medical Research Center, Seoul (Korea, Republic of)

    2014-02-15

    We aimed to improve Tc-99m DTPA glomerular filtration rate (GFR) scintigraphy (Gates' method) in a prospective study using Cr-51 EDTA GFR test as a gold standard. Fifty-seven Tc-99m DTPA GFR scintigrams in 45 subjects (male/female = 33:12, age = 45.9 ± 17.6 years, 14 healthy volunteers and 31 nephrectomised patients) were compared using Cr-51 EDTA GFR tests. Using the %renal uptake of Tc-99m DTPA and Cr-51 EDTA GFR, a revised equation for GFR was established through linear regression analysis. The revised equation for improved GFR was GFR(mL/min) = (%renal uptake x 11.7773) - 0.7354. Gates' original GFRs (70.1 ± 20.5 mL/min/1.73 m{sup 2}) were significantly lower than Cr-51 EDTA GFRs (97.0 ± 31.9 mL/min/1.73 m{sup 2}; P < 0.0001), but the improved GFRs (98.0 ± 26.3 mL/min/1.73 m{sup 2}) were not different from (P = 0.7360) and had a significant correlation with (r = 0.73, P < 0.0001) the Cr-51 EDTA GFRs. The revised GFR equation effectively demonstrated perioperative GFR changes in kidneys that were operated on and the contralateral kidneys at 3 and 6 months post-partial nephrectomy (n = 25). GFR measurement using Tc-99m DTPA scintigraphy could be significantly improved by a revised equation derived from the comparison with Cr-51 EDTA GFR. (orig.)

  18. Evaluation of lung epithelial permeability in the volatile substance abuse using Tc-99m DTPA aerosol scintigraphy.

    Science.gov (United States)

    Cayir, Derya; Demirel, Koray; Korkmaz, Meliha; Koca, Gokhan

    2011-10-01

    Chronic inhalant use is associated with significant toxic effects, including neurological, renal, hepatic, and pulmonary damage. However, there is a paucity of reports regarding respiratory complications in inhalant abusers. The aim of this study was to evaluate pulmonary epithelial permeability in the volatile substance abuse (VSA) using Tc-99m DTPA aerosol scintigraphy. This study included 18 patients with volatile substance abuse and 18 volunteer controls. All of patients and controls were smokers. Tc-99m DTPA aerosol scintigraphy was performed in all cases. Time-activity curves from each lung were generated and clearance half-time (T(1/2)) of Tc-99m DTPA were calculated. T(1/2) of whole lung was calculated as a mean of the T(1/2) of left and right lung. The T(1/2) values of Tc-99m DTPA clearance in the substance abusers were significantly decreased as compared to the control group with respective mean values of 28.86 ± 8.44, and 62.14 ± 26.12 min (p = 0.001). It was seen Tc-99m DTPA clearance from lung was faster as the duration of substance abuse was increased. Tc-99m DTPA pulmonary clearance is markedly accelerated in the volatile substance abuse. This suggests that inhalant abuse of substance may produce abnormalities in pulmonary alveolo-capillary membrane function.

  19. 99mTc-Alafosfalin: an antibiotic peptide infection imaging agent

    International Nuclear Information System (INIS)

    Tsopelas, C.; Penglis, S.; Ruszkiewicz, A.; Bartholomeusz, F.D.L.

    2003-01-01

    The radiolabeled antibiotic peptide 99m Tc-alafosfalin was assessed as an infection imaging agent in a rat model by comparison with 99m Tc-DTPA and 99m Tc-leukocytes. 99m Tc-alafosfalin was prepared via an instant cold kit and 99m Tc-leukocytes were prepared using 99m Tc-stannous fluoride colloid in an ex vivo labeling procedure of whole blood. In separate experiments, the three radiotracers were administered to rats infected with staphylococcus aureus. Quantitative biodistribution studies were performed as well as scintigraphic images and histopathology. 99m Tc-alafosfalin is a stable product, obtained in high radiochemical purity (>95%). This agent was mainly renally excreted, with low liver, spleen and bone uptake, and resulted in a mean ratio of infected/non-infected thighs of 4.3/1.0 at 4 hr post radiotracer injection. 99m Tc-DTPA gave a corresponding ratio of 1.9/1.0 and 99m Tc-leukocytes gave 20.0/1.0 at the same time point. An in vitro assay found the level of 99m Tc-alafosfalin binding to staphylococcus aureas higher than 99m Tc-DTPA (10% versus 1% respectively). 99m Tc-alafosfalin accumulates at sites of infection in a rat model better than the perfusion molecule 99m Tc-DTPA, yet less than 99m Tc-leukocytes. The distribution characteristics of this 99m Tc-antibiotic peptide would be an advantage in imaging abdominal and soft tissue infection

  20. Evaluation of renal function using [sup 99m]Tc-MAG3; Comparison with [sup 123]I-OIH and [sup 99m]Tc-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Teruhiko; Aburano, Tamio; Shuke, Noriyuki (Kanazawa Univ. (Japan). School of Medicine) (and others)

    1993-07-01

    The utility of [sup 99m]Tc-mercaptoacetyltriglycine (MAG3) was studied clinically. In the renography obtained with [sup 99m]Tc-MAG3, the abdominal aorta and the common iliac arteries were clearly visualized in the vascular phase. Due to less background activity and high target to background ratio, the quality of [sup 99m]Tc-MAG3 image was superior to that of [sup 123]I-OIH or [sup 99m]Tc-DTPA image. The parameters on the renogram including T[sub max], T[sub 2/3], and T[sub 1/2] were compared. The correlation of T[sub max] and T[sub 2/3] or T[sub 1/2] were not significant between [sup 99m]Tc-MAG3 and [sup 123]I-OIH. Another parameter of C[sub 20]/C[sub max], where C[sub 20] and C[sub max] are renal activities at 20 min after injection and at T[sub max] respectively, showed an excellent correlation between [sup 99m]Tc-MAG3 and [sup 123]I-OIH. Using C[sub 20]/C[sub max], pattern of renogram can be characterized numerically. Concerning the relation between C[sub 20]/C[sub max] and renogram pattern, standard renogram pattern showed the C[sub 20]/C[sub max] value of less than 0.4, while hypofunctioning pattern showed more than 0.5. The correlation coefficient between the renal uptake of [sup 99m]Tc-MAG3 and [sup 123]I-OIH was 0.880 with a correlation plot: 'Y=1.16X-0.043', where X and Y represent renal uptake of [sup 99m]Tc-MAG3 and [sup 123]I-OIH, respectively. It can be concluded that [sup 99m]Tc-MAG3 is a useful renal imaging agent as an alternative to [sup 123]I-OIH, in order to evaluate the proximal tubular function and calculate ERPF. (author).

  1. Pulmonary epithelial clearance of 99mTc-DTPA after thrombin-induced pulmonary microembolism

    International Nuclear Information System (INIS)

    Cooper, J.A.; Feustel, P.J.; Line, B.R.; Malik, A.B.

    1986-01-01

    We investigated the effect of thrombin-induced pulmonary microembolism on the pulmonary clearance rate of aerosolized 99mTc diethylenetriamine pentaacetic acid (99mTc-DTPA) in awake, chronically prepared sheep. Chest activity was recorded after administration of a 0.44 micron aerosol of 99mTc-DTPA. Decay-corrected data were fit to an exponential and expressed as percent decrease per min (%/min). Sheep were given alpha-thrombin intravenously (80 U/kg for 10 min) 60 min after the aerosol administration. The clearance rate prior to alpha-thrombin was 0.35 +/- 0.05 %/min (mean +/- SEM). During alpha-thrombin administration, the clearance rate increased to 5.84 +/- 0.70 %/min (p less than 0.001 from baseline), but returned to 0.41 +/- 0.06 %/min within 30 min after the end of the thrombin infusion. The increased clearance rate during alpha-thrombin administration was not due to increased lung volume since alpha-thrombin did not change functional residual capacity. Moreover, the clearance rate was unchanged during gamma-thrombin administration, which does not induce coagulation, or during alpha-thrombin challenge in defibrinogenated animals. alpha-thrombin administration in neutrophil-depleted sheep caused a transient increase in DTPA clearance similar to that in control sheep, suggesting that the increase occurred independently of neutrophils. The results indicate that alpha-thrombin causes a large, transient increase in 99mTc-DTPA clearance, which may be the result of increased epithelial permeability. This response is dependent on the activation of intravascular coagulation

  2. Effect of different levels of continuous positive airway pressure on the 99mTc-DTPA lung clearance

    Directory of Open Access Journals (Sweden)

    Dulciane Nunes Paiva

    2014-04-01

    Full Text Available Backgound and Objectives: Positive airway pressure continues (CPAP produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA, along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½ that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005. However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.

  3. Clearance of 99mTc-DTPA and experimentally increased alveolar surfactant content

    International Nuclear Information System (INIS)

    Bos, J.A.H.; Wollmer, P.; Bakker, W.; Hannappel, E.; Lachmann, B.

    1992-01-01

    The authors measured clearance of 99m Tc-labeled diethylenetriamine pentaacetic acid ( 99m Tc-DTPA) in rabbits with experimentally increased alveolar surfactant content. In one group of animals, surfactant production was increased by treatment with ambroxol, and another group of animals was treated with tracheal instillation of natural surfactant. A group of untreated control animals and animals treated with instillation of saline were also studied. Clearance was measured during standard conditions of mechanical ventilation and during ventilation with large tidal volumes. In ambroxol- and surfactant-treated groups, clearance rate was reduced compared with untreated control animals. In contrast, clearance rate increased after saline instillation. The differences were observed at both modes of ventilation. The findings indicate that the pulmonary surfactant system is a rate-limiting factor for the clearance of 99m Tc-DTPA and that the volume dependence of clearance is not explained by stretching of the alveolar wall only. 28 refs., 2 figs., 1 tab

  4. Influence of tyramine-induced neurotoxicity on kinetics of first-pass brain TC-99m-DTPA

    International Nuclear Information System (INIS)

    Malveaux, E.; Schmidt, F.; Sarper, R.; Camp, V.; Faraj, B.A.

    1986-01-01

    Tyramine (T) induces coma in phenelzine-treated dogs. The objective of the present investigation was to examine the influence of T in MAO-inhibited dogs on the kinetics of Tc-99m-DTPA during its first passage through the brain by nuclear imaging. The study began with anesthetized dogs (n=10) in a supine position over the camera detector. Data acquisition was started simultaneously following the rapid intracarotid injection of Tc-99m-DTPA (30 mCi) and 60 0.5 second images of the brain were taken. T induced increased uptake with a concomittant impairment in the elimination of Tc-99m-DPTA from the brain of these treated animals as compared to controls. This was accompanied by an appreciable reduction in hemispheric cerebral blood flow (CBF) (56 +/- 19 vs 110 +/- 16 ml/100g/min). Increased cerebrovascular permeability of Tc-99m-DTPA and decreased CBF correlated significantly with development of intracranial hypertension and elevation in CSF catecholamines in these animals. T may have implication in the development of cerebral edema of Reye's syndrome

  5. Radiation protect during the ventilation scintigraphy of Tc99m DTPA radioaerosol in pediatric application

    International Nuclear Information System (INIS)

    Chen, Yu-Wen; Dai, Zen-Kong; Huang, Ying-Fong; Jong, Shiang-Bing

    2000-01-01

    Lung ventilation-perfusion scintigraphy is of great value for the management of patients with both primary lung disease and heart disease, by proving patho- physiological information of importance for the diagnosis, follow-up and functional evaluation of the patients. Krypton 81m radioactive gas is preferable for pediatric application due to its short half-life. However, the rubidium-krypton 81m generator is not popular in hospital of our country. Tc99m DTPA radioaerosol ventilation scintigraphy has its unique convenient for clinical application. But, the most disadvantage of clinical application of Tc99m DTPA radioaerosol is contamination of environment when the poor-cooperative patient can't breathe by mouth. For this reason, we design the certain procedure to reduce the radioaerosol contamination. During May to Aug., 1999, we collect 36 pediatric patients (male to female ratio 2:1, age from 6 months to 20 years old) with clinical history of lung or heart disease, including congenital heart disease, asthma and so on. Before the cases receive 10 to 15 mCi Tc99m DTPA radioaerosol ventilation scan, all of them were trained with breath training. And during the ventilation scintigraphy, the special mouth mask is designed to prevent the radioaerosol leakage into atmosphere. Then Geiger-Muller survey meter was arranged to detect the environmental contamination of radioaerosol in the mask, one and two metes away from the mask every 10 minutes during ventilation scintigraphy procedure and 1 hour after finishing image. Two nuclear medicine physicians evaluated imaging quality of ventilation scintigraphy. Results: Among thirty-six pediatric patients with prior breath training, thirty-two cases are successful to proceed the Tc99m DTPA ventilation scintigraphy. The other four cases that were under three-year-old fail to receive ventilation scintigraphy. There is limited detectable radioactivity in the mouth mask at early 10 minute by Geiger-Muller counter. No significant

  6. Radioisotopic investigation of renal arterial hypertension using 99m Tc-DTPA

    International Nuclear Information System (INIS)

    Champailler, A.; Defour-Decousus, M.; Houzard, C.; Healy, J.C.; Gonthier, R.; Juge, J.; Berthoux, F.C.

    1984-01-01

    To evaluate the clinical validity of renal investigation using 99m Tc-DTPA, 60 hypertensive patients divided into four groups according to diagnosis were studied: 1) renovascular hypertension (22 patients); 2) chronic pyelo-nephritis (11 patients); 3) renal hypoplasia (12 patients); 4) hypertension due to bilateral parenchymatous (15 patients). A good correlation was found between clearance of DTPA and creatinine clearance/1.73 m 2 body surface (n = 51, r = 0.68, p 2 BS [fr

  7. Using 99mTc-DTPA radioaerosol inhalation lung scan as compared with computed tomography to detect lung injury in blunt chest trauma

    International Nuclear Information System (INIS)

    Esme, H.; Kaya, E.; Solak, O.; Yavuz, Y.; Yurumez, Y.; Sezer, M.

    2007-01-01

    Detection of pulmonary contusion in patients with blunt chest trauma is very important so as to commence therapy immediately to avoid irreversible damage. The purpose of our study was to evaluate the efficacy of technetium-99m diethylene triamine penta-acetic acid ( 99m Tc-DTPA) aerosol inhalation lung scintigraphy in comparison with chest computed tomography (CT) in the diagnosis of pulmonary contusion at acute blunt chest trauma. Twenty-nine patients with isolated blunt chest trauma were referred to the emergency department of our hospital, and nine healthy people participated in this study. Sixteen patients who had pulmonary contusion on CT scans were referred to as group 1, and 13 patients who had normal CT scans as group 2. Nine healthy people comprised a control group. 99m Tc-DTPA aerosol inhalation lung scintigraphy was performed on the first day in all patients. The mean half time (T 1/2 ) and penetration index values of 99m Tc-DTPA clearance were significantly lower in groups 1 and 2 compared with the control group. Among the three groups, there were no significant differences in arterial blood gas analysis except for PO 2 . The mean T 1/2 value of 99m Tc-DTPA clearance did correlate with PO 2 values but not with pH, PCO 2 , or HCO 3 values. 99m Tc-DTPA radioaerosol inhalation lung imaging may serve as a useful adjunct and supportive method to chest CT scanning for detecting mild pulmonary contusion. (author)

  8. Lung clearance of 99mTc-DTPA aerosols in chronic obstructive pulmonary disease and interstitial pneumopathy diffuse

    International Nuclear Information System (INIS)

    Maliska, Carmelindo; Mello, Rossana Corbo de; Fonseca, Lea M.B.; Maliska, Celsa M.; Wolosker, Sara; Albernaz, Marta S.; Marinho, J.C.A.; Lima, Jose E.T.; Jansen, Jose M.

    1996-01-01

    An increasement in pulmonary epithelial permeability occurs when the alveolar-capillary units are disrupted. This permeability increasement can be measured by the 99m Tc-DTPA aerosol washout from lungs. Twenty three patients (10 healthy normal controls, 6 with COPD, 5 with diffuse infiltrative lung disease (DILD) and 2 asyntomatic patients that underwent radioiodine therapy dose) in order to verify the lung clearance rate of 99m Tc-DTPA in our population. The mean and standard deviation of pulmonary clearance rate in the normal group was 0,722±0,098%min -1 . The COPD patients rate resembled to the normal group rate. Four in five DILD patients had increased pulmonary clearance rate. The 2 patients that underwent radioiodine therapeutic showed normal clearance values of 99m Tc-DTPA from lungs. Our preliminary observations suggest that 99 'm Tc-DTPA clearance can be used as valuable tool in assessing early stages of pulmonary disorders in systemic diseases that may affect the lung. We also suggest that COPD does not seem to raise the pulmonary epithelial permeability. (author)

  9. Regional respiratory clearance of aerosolized /sup 99m/Tc-DTPA: posture and smoking effects

    International Nuclear Information System (INIS)

    Dusser, D.J.; Minty, B.D.; Collignon, M.A.; Hinge, D.; Barritault, L.G.; Huchon, G.J.

    1986-01-01

    We studied 10 healthy nonsmokers and 8 healthy smokers, in both the upright and supine position, to investigate whether regional differences in respiratory clearance of technetium-99m-labeled diethylenetriamine pentaacetic acid /sup 99m/Tc-DTPA (RC-DTPA) existed and to assess the influence of posture and smoking on the regional RC-DTPA. RC-DTPA was assessed by the lung clearance rates (%/min) of aerosolized /sup 99m/Tc-DTPA (0.8 micron MMD; 2.4 GSD), using data corrected for recirculating radioactivity, in the upper (zone 1), middle (zone 2), and lower (zone 3) posterior lung fields. In nonsmokers, RC-DTPA in zone 1 was faster than in zone 2 or 3 in both the upright (P less than 0.001) and supine positions (P less than 0.0). No effect was produced by changes in posture on the regional RC-DTPA. In smokers, RC-DTPA was increased in all zones compared with the nonsmokers (P = 0.004), with a further increase in RC-DTP in zone 1 in the upright posture compared with the other regions (P less than 0.001). We conclude that in nonsmokers regional RC-DTPA is faster in zone 1 than in other zones, and this is not related to recirculation of radioactivity; posture does not modify the regional RC-DTPA of nonsmokers; smoking increases RC-DTPA in all zones and more in zone 1 in the upright posture

  10. Stability, protein binding and clearance studies of [99mTc]DTPA. Evaluation of a commercially available dry-kit

    DEFF Research Database (Denmark)

    Rehling, M

    1988-01-01

    [99mTc]DTPA has achieved widespread use for the measurement of glomerular filtration rate (GFR) with the single injection plasma clearance technique and for gamma-camera renography. However, the quality of the commercial preparations varies. The purpose of the present investigation was to study...... the quality of a commercial [99mTc]DTPA preparation (C.I.S., France) with reference to stability, protein binding and accuracy of the determined plasma clearance values as a measure of GFR. The stability of the preparations was studied by thin-layer chromatography, the in vitro protein binding by Sephadex.......7% and 1.1%, respectively. The plasma clearance of [99mTc]DTPA was on an average 3.7% higher than that of [51Cr]EDTA in 27 patients. It is concluded that the [99mTc]DTPA preparation is reliable for the measurement of GFR. The preparation is stable for at least six hours at room temperature...

  11. Lung function declines in patients with pulmonary sarcoidosis and increased respiratory epithelial permeability to 99mTc-DTPA

    International Nuclear Information System (INIS)

    Chinet, T.; Dusser, D.; Labrune, S.; Collignon, M.A.; Chretien, J.; Huchon, G.J.

    1990-01-01

    Respiratory epithelial clearance of 99m Tc-DTPA (RC-Tc-DTPA) and pulmonary function tests (PFT) were determined at intervals of 6 or 12 months in 37 untreated, nonsmoking patients with sarcoidosis over a period of 6 to 36 months. PFT included the measurements of total lung capacity (TLC), vital capacity (VC), FEV1, and diffusing capacity for carbon monoxide. No difference was found between the respiratory clearance of 113m In-DTPA (2.25 +/- 1.00%/min) and RC-Tc-DTPA (2.29 +/- 1.11%/min) in eight patients with pulmonary sarcoidosis. Pulmonary function decreased 15% or more in at least 2 function tests during 11 follow-up periods, but it remained stable during 47 follow-up periods. In patients whose lung function deteriorated, RC-Tc-DTPA increased to 3.51 +/- 1.55%/min; in contrast, in patients whose lung function remained stable, regardless of the initial values, RC-Tc-DTPA was normal (1.00 +/- 0.50%/min; p less than 0.001). In eight patients who were treated with corticosteroids, RC-Tc-DTPA decreased from 3.48 +/- 1.31%/min to 1.56 +/- 0.64%/min (p less than 0.001), and PFT improved. We conclude that in nonsmokers with pulmonary sarcoidosis, increased RC-Tc-DTPA is not related to dissociation of 99mTc from DTPA, RC-Tc-DTPA is increased when pulmonary function decreases, and, when increased, RC-Tc-DTPA decreases with corticosteroid therapy

  12. Lung clearance of 99m Tc- DTPA in systemic lupus erythematous

    International Nuclear Information System (INIS)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T.; Cunha, R.D.; Marroni, B.J.

    2002-01-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  13. Iliac renal ectopia explored by {sup 99m}Tc-DTPA and {sup 99m}Tc-DMSA scintigraphy. Report of one case; Ectopie renale iliaque exploree par scintigraphie au {sup 99m}Tc-DTPA et au {sup 99m}Tc-DMSA. A propos d'un cas

    Energy Technology Data Exchange (ETDEWEB)

    Ghfir, I.; Ben Rais, N. [Hopital Ibn Sina, CHU de Rabat, Service de Medecine Nucleaire de Rabat (Morocco)

    2008-11-15

    Introduction Renal ectopia is a malposition by anomaly of migration during the embryonic development. It can be high, low or crossed. Association with an obstructive malformation is rather frequent. The objective of this work is to highlight the interest of {sup 99m}Tc-DTPA and {sup 99m}Tc-DMSA scintigraphy in the exploration of this type of malformation through the observation of a patient presenting an iliac right renal ectopia associated with an ureteral-pelvic junction syndrome. Observation A 38-year-old patient with an ureteral-pelvic junction syndrome on a right iliac renal ectopia revealed by intravenous urography. The dynamic renal scintigraphy using {sup 99m}Tc-DTPA with furosemide test evidenced an organic obstruction in the right urinary tract with a right renal function estimated at 40% on the {sup 99m}Tc-DMSA scintigraphy. A right pyelo-plasty was carried out. The evolution was marked by the disappearance of pain and a remarkable improvement of the permeability of the right urinary tract on the follow-up scintigraphy. Discussion Renal ectopia is not an unfrequent urinary malformation. It is generally low, pelvic or iliac. Association with an ureteral-pelvic junction obstruction is rather frequent. In this purpose, renal scintigraphy intervenes as a means of functional exploration, with low ionizing radiation and non-invasive to assess the permeability of the urinary tracts of the ectopic kidney and to appreciate the relative renal function. This contributes to the orientation of diagnosis and the improvement of therapeutic strategy.

  14. Uptake of 153Sm-DTPA-bis-biotin and 99mTc-DTPA-bis-biotin in rat as-30D-hepatoma cells

    International Nuclear Information System (INIS)

    Correa-Gonzalez, Luis; Arteaga de Murphy, Consuelo; Ferro-Flores, Guillermina; Pedraza-Lopez, Martha; Murphy-Stack, Eduardo; Mino-Leon, Dolores; Perez-Villasenor, Graciela; Diaz-Torres, Yaneth; Munoz-Olvera, Rodrigo

    2003-01-01

    Labeled biotin has been used mainly for pretargeted therapy, an approach for increasing the amount of radioactivity delivered to a cancer cell. The aim of this investigation was to prepare 153 Sm-DTPA-bis-biotin and 99m Tc-DTPA-bis-biotin in order to study their in vitro and in vivo uptake in rat AS-30D hepatoma cells found in ascites and in implanted tumor. DTPA-bis-biotin (pH 8) was 153 Sm labeled with 153 SmCl 3 and 99m Tc-DTPA-bis-biotin was prepared via SnCl 2 reduction. Radiochemical purity was >98% in both cases. AS-30D hepatoma cells were obtained from ascites of a rat with hepatoma and were propagated in the peritoneum cavity of normal rats. In vitro ascites cell 153 Sm-DTPA-bis-biotin uptake was compared with 153 SmCl 3 cell uptake. The ratio cell 153 Sm-DTPA-bis-biotin/ 153 SmCl 3 was 39.6 and when avidin was added it increased to 50. The ratio 99m Tc-DTPA-bis-biotin/TcO 4 Na was 8.7. Concentration of 153 Sm-DTPA-bis-biotin in tumor 2, 3 and 24 h after administration, was 5, 15 and 3 times higher than in normal muscle (T/nT). Biodistribution in a 0.083-24 h time period showed that 153 Sm-DTPA-bis-biotin was taken up only by ascites tumor cells and hepatoma cells. Two and 3 h ratio ascites/liver (As/Lv) was 6.4 and 6.0. For 99m Tc-DTPA-bis-biotin 2 and 3 h T/nT was 15.7 and 4.7 and 2 h As/Lv was 1.4. In conclusion, both radiopharmaceuticals show high uptake in rat AS-30D hepatoma cells in ascites and in implanted tumor. Since lung, thyroid, kidney, liver or pancreas carcinomas are ascites producing cancers 153 Sm-DTPA-bis-biotin would be an adequate therapeutic radiopharmaceutical for these patients whose life quality would be enhanced with control of ascites, and a reduction of the primary tumor and its metastases

  15. Evaluation of three algorithms to calculate the relative renal function with {sup 99}Tc-DTPA; Evaluation de trois algorithmes pour calculer la fonction renale relative au {sup 99}Tc-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Charfeddine, S.; Maaloul, M.; Kallel, F.; Chtourou, K.; Guermazi, F. [EPS Habib Bourguiba, Service de Medecine Nucleaire, Sfax (Tunisia)

    2006-06-15

    The aim of our study is to estimate the reproducibility and the exactitude of three algorithms to determine with {sup 99m}Tc-DTPA the relative function of each kidney. Methods: a prospective study was carried out in voluntary patients. Reproducibility was studied in 11 patients who underwent had two examinations with {sup 99m}Tc-DTPA. Exactitude was evaluated in 35 patients who had an additional scintigraphy with {sup 99m}Tc-DMSA taken as a reference. To determine the relative renal function with {sup 99m}Tc-DTPA, three algorithms using various background subtraction methods and time intervals were applied. Results and conclusion: the method of the integral was the most reproducible and exact. It was little influenced by the choice of the interval of time. The reproducibility and the exactitude of the Patlak method were worse, especially in case of renal insufficiency or hydronephrosis. A high background and poor counting statistics explain why Patlak was less powerful with {sup 99m}Tc-DTPA than with {sup 99m}Tc-MAG3. The method of the slopes should not be recommended any more. (author)

  16. Radiation dose to bladder wall following the administration of sup(99m)Tc-microspheres and sup(99m)Tc-DTPA

    International Nuclear Information System (INIS)

    Smith, T.

    1981-01-01

    Castronovo et al. (Health Phys. Vol. 39, p 112, 1980) reported a method of calculating the dose to the bladder wall following administration of sup(99m)Tc human albumin microspheres (sup(99m)Tc-HAM) for lung perfusion scanning. The present note comments that (1) the dosimetry is estimated for an unusual bladder voiding schedule and no indication is given of the variation of dose to be expected with different schedules, and (2) that the method assumes linear biological excretion of the radiopharmaceutical into the bladder in any particular filling period. It is shown that whilst this is a valid approximation in the case considered, it is not a generally applicable principle. Values of bladder wall dose commitments following intravenous administration of sup(99m)Tc-HAM or sup(99m)Tc DTPA are tabulated. Values for constant voiding cycles are presented for four different bladder voiding periods between 2 and 8 hr, and for three different methods of calculation:-a method described in this paper, the linear excretion method of Castronovo et al., and the method of Snyder et al. (ORNL-4584, pp. 206-208, 1970) which allows for urine flow rate. (U.K.)

  17. Significance of renal scintigraphy with 99mTc-DTPA for the diagnosis of diabetic nephropathy

    International Nuclear Information System (INIS)

    Lin Jun; Zhao Shuhao; Guo Rong; Lin Haoxue; Xie Zhichun

    1995-01-01

    99m Tc-DTPA renography was performed in 64 cases of type II diabetes mellitus and 20 control subjects. The value of GFR in the controls was 113 +-11.7 ml/min. The value of GFR in 15 of 43 patients with negative proteinuria was more than 140 ml/min, but GFR in the 21 diabetes with positive proteinuria was 76 +- 32.9 ml/min. These data indicated that 99m Tc-DTPA renography is an accurate and sensitive method for evaluation of hyperfiltration in early diabetes mellitus

  18. The measurement of 99mTc-DTPA pulmonary clearance in normals, asymptomatic smokers and diabetic patients

    International Nuclear Information System (INIS)

    Kim, In Ju; Kim, Seong Jang; Kim, Yong Ki; Kim, Yun Seong; Lee, Min Ki; Park, Soon Kew

    1998-01-01

    We measured pulmonary epithelial permeability by 99m Tc-DTPA radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate 99m Tc-DTPA radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. We performed 99m Tc-DTPA radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). 99m Tc-DTPA clearance half-time (T 1/2 ) was calculated, then compared with the result of chest radiography and pulmonary function test. Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiophaty were significantly older (p 1/2 of normal subjects and asymptomatic smokers were significantly different (65.2±23.7 min vs 39.6±9.8 min, p 1/2 was 90.5±46.5 min and significantly delayed when compared with those of normals and asymptomatic smokers (p 1/2 of diabetic patients without microangiopathy, 70.0±12.7 min, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the T 1/2 and spirometric parameters including DLco, FVC, FEV 1 , FEV 1 /FVC (%) and FEF 25-75% in all subjects, and between the T 1/2 and duration of diabetes in diabetic patients. Eventhough the influence of age can't be excluded, delayed 99m Tc-DTPA clearance half-time (T 1/2 ) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy

  19. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  20. Effect of increased surface tension and assisted ventilation on /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Jefferies, A.L.; Kawano, T.; Mori, S.; Burger, R.

    1988-01-01

    Experiments were performed to determine the effects of conventional mechanical ventilation (CMV) and high-frequency oscillation (HFO) on the clearance of technetium-99m-labeled diethylenetriamine pentaacetate (/sup 99m/Tc-DTPA) from lungs with altered surface tension properties. A submicronic aerosol of /sup 99m/Tc-DTPA was insufflated into the lungs of anesthetized, tracheotomized rabbits before and 1 h after the administration of the aerosolized detergent dioctyl sodium sulfosuccinate (OT). Rabbits were ventilated by one of four methods: 1) spontaneous breathing; 2) CMV at 12 cmH2O mean airway pressure (MAP); 3) HFO at 12 cmH2O MAP; 4) HFO at 16 cmH2O MAP. Administration of OT resulted in decreased arterial PO2 (PaO2), increased lung wet-to-dry weight ratios, and abnormal lung pressure-volume relationships, compatible with increased surface tension. /sup 99m/Tc-DTPA clearance was accelerated after OT in all groups. The post-OT rate of clearance (k) was significantly faster (P less than 0.05) in the CMV at 12 cmH2O MAP [k = 7.57 +/- 0.71%/min (SE)] and HFO at 16 cmH2O MAP (k = 6.92 +/- 0.61%/min) groups than in the spontaneously breathing (k = 4.32 +/- 0.55%/min) and HFO at 12 cmH2O MAP (4.68 +/- 0.63%/min) groups. The clearance curves were biexponential in the former two groups. We conclude that pulmonary clearance of /sup 99m/Tc-DTPA is accelerated in high surface tension pulmonary edema, and this effect is enhanced by both conventional ventilation and HFO at high mean airway pressure

  1. /sup 99m/Tc labelled ulcer avid agents

    International Nuclear Information System (INIS)

    Scopinaro, F.; Linari, G.; Baldieri, M.; Liberatore, M.; Corti, E.; Signori, C.

    1986-01-01

    Sulfated oligosaccharides have some interesting pharmacological properties: they are anticoagulants and protect the ulcerative areas of epithelia by precipitating over ulcers together with exudative proteins. Some sucralfate labelling methods using /sup 75/Se, /sup 111/In, /sup 99m/Tc-albumin and /sup 99m/Tc-DTPA have been reported. Only the /sup 99m/Tc-sucralfate has, at present, the requisites to be used as an ulcer-seeking agent. The aim of this study were: (a) to introduce a simple and easy-to-repeat method for the labelling of sucralfate with /sup 99m/Tc-DTPA; (b) to demonstrate that it is possible to label the sucrose octasulfate directly with /sup 99m/Tc without the aid of other ligands (e.g. DTPA)

  2. 99mTc-DTPA aerosol for same-day post-perfusion ventilation imaging: Results of a multicentre study

    International Nuclear Information System (INIS)

    Koehn, H.; Koenig, B.; Bachmayr, S.; Markt, B.; Eber, O.; Lind, P.; Galvan, G.; Rettenbacher, L.; Holm, C.; Ogris, E.

    1993-01-01

    A multicentre study was performed in an attempt to evaluate a submicronic technetium-99m diethylene triamine penta-acetic acid aerosol generated by a newly developed delivery system, the aerosol production equipment (APE nebulizer), for same-day post-perfusion ventilation imaging in patients with clinically suspected pulmonary embolism. Quantitative comparison between the DTPA aerosol and krypton gas demonstrated a close correlation with respect to regional pulmonary distribution of activity and peripheral lung penetration (n=14, r=0.94, P 99m Tc-labelled DTPA aerosol is well suited for fast same-day post-perfusion ventilation imaging in patients with clinical suspicion of pulmonary embolism. (orig.)

  3. Technetium-99m DTPA renal flow studies in Goldblatt hypertension

    International Nuclear Information System (INIS)

    Nally, J.V.; Clarke, H.S.; Windham, J.P.; Grecos, G.P.; Gross, M.L.; Potvin, W.J.

    1985-01-01

    Computer-assisted dynamic renal studies were performed on a group of 14 mongrel dogs before and after the induction of unilateral renal artery stenosis. Ninety-second technetium-99m diethylenetriaminepentaacetic acid ([/sup 99m/Tc]DTPA), 15-min [/sup 99m/Tc]DTPA, and 30-min iodine-131 orthoiodohippurate ([ 131 I]hippuran) time-activity curves were analyzed and correlated with reduction of renal blood flow as measured by electromagnetic flow probe and PAH clearance techniques. For blood flow reductions greater than 33%, the [/sup 99m/Tc]DTPA studies were judged diagnostic of unilateral renal artery stenosis in all cases, whereas the [ 131 I]hippuran time-activity curves were indicative of stenosis in only six of ten studies. Thus, in this model we find the computer-assisted 90-sec [/sup 99m/Tc]DTPA renal flow study to be superior to conventional [ 131 I]hippuran renography in the diagnosis of moderate-to-serve unilateral renal artery stenosis

  4. Lung clearance of {sup 99m} Tc- DTPA in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Dept. de Medicina Interna; Cunha, R.D.; Marroni, B.J. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Servico de Medicina Nuclear]. E-mail: rxavier@hcpa.ufrgs.br

    2002-06-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  5. Evaluation of Renal Function in Children by Tc-99m DTPA Scintigraphy

    Directory of Open Access Journals (Sweden)

    Sevin Ayaz

    2016-09-01

    Full Text Available Aim: Dynamic renal scintigraphy can demonstrate both structural and functional renal pathologies. Our aim was to evaluate renal functions in children by technetium-99m diethylenetriaminepentaacetic acid (Tc-99m DTPA dynamic renal scintigraphy, and todetermine the frequency of scintigraphically detectable atrophic kidneys. Material and Method: Dynamic renal scintigraphy studies of 17 children (12 males, five females with urinary system complaints, having a mean age of 6.15 ± 4.41 years, were included in this retrospective study. Images were obtained with a dual-head gamma camera after intravenous (IV injection of Tc-99m DTPA. Results: The functions of 34 kidneys were evaluated. Decreased perfusion of the left and right kidneys was detected in 35.3% (n=6/17 and 11.8% (n=2/17 of cases, respectively. Prolongation in Tmax of the left and right kidneys was shown in 52.9% (n=9/17 and 29.4% (n=5/17 of the cases, respectively. Glomerular filtration rate of the left and right kidneys was normal in 64.7% (n=11/17 and 88.2% (n=15/17 of cases, respectively. Delayed excretion of the left and right kidneys wasdetected in 29.4% (n=5/17 and 11.8% (n=2/17 of cases, respectively. Stasis of urine in the left and right kidneys which responded to IV diuretics wasdemonstrated in 58.8% (n=10/17 and 70.6% (n=12/17 of cases, respectively. Dynamic renal scintigraphy findings in favour of left and right renal atrophy were obtained in 17.6% (n=3/17 and 5.9% (n=1/17 of cases, respectively. Discussion: Dynamic renal scintigraphy with Tc-99m DTPA was found to be useful in the evaluation of renal functions of children and in determining the frequency of atrophic kidneys.

  6. Peptic ulcer imaging with /sup 99m/Tc sucralfate and possible advantages of /sup 99m/Tc sucrose octasulfate

    International Nuclear Information System (INIS)

    CentiColella, A.; Scopinaro, F.

    1986-01-01

    Sucralfate is a basic aluminum salt of sucrose octasulfate that protects the damaged mucosa and also the normal mucosa from peptic aggression. In fact sucralfate adheres to the mucosa as pH decreases below 4, and buffers the acid, slowly releasing sucrose octasulfate that forms insoluble complexes with the proteins exuded by the ulcers, or is washed out of the stomach. Sucralfate itself is also able to precipitate with proteins in the ulcers. Sucralfate may be labelled by several methods: /sup 99m/Tc HSA, /sup 99m/Tc DTPA, /sup 75/Se, /sup 111/In. The aims of this study were to evaluate the clinical results obtained using /sup 99m/Tc DTPA sucralfate, which the authors believe is the only labelled sucralfate suitable for clinical studies and to discuss the possible diagnostic uses of /sup 99m/Tc sucrose octasulfate. In fact, it has been possible to label the sucrose octasulfate either with /sup 99m/Tc DTPA or with /sup 99m/Tc without the use of intermediate ligands

  7. Pulmonary clearance of 99mTc-DTPA aerosol in patients with progressive systemic scleroderma

    International Nuclear Information System (INIS)

    Tateno, Madoka; Nakano, Akihiko; Hasegawa, Akira; Watanabe, Naoyuki; Oriuchi, Noboru; Inoue, Tomio; Endo, Keigo; Sasaki, Yasuhito.

    1992-01-01

    Alveolar epithelial permeability was assessed in 32 patients with progressive systemic scleroderma (PSS), using 99m Tc-DTPA aerosol. Immediately after the inhalation of 99m Tc-DTPA aerosol for 3 to 6 minutes under normal tidal breathing, lung was imaged sequentially for 30 minutes from the posterior by a gamma camera and exponential fitting was processed on the time activity curve. T 1/2 (min) was used as a parameter for the evaluation of permeability of alveolar epithelium. Patients with collagen disease showed shorter T 1/2 (T 1/2 =43.7±23.8 min) than the normal volunteers (T 1/2 =76.8±8.7 min). No significant difference was observed between patients with or without interstitial changes on the chest CT. Significant correlation was not observed between T 1/2 and %VC or %DLco. In 8 cases, studies were repeated in the interval of 3 to 19 months. Improvement of T 1/2 was seen in 4 cases, independent of CT findings. These results suggest that 99m Tc-DTPA aerosol clearance study provides information independent from other lung examinations, and may be useful for the assessment of lung interstitial changes in patients with PSS. (author)

  8. Use of /sup 99m/Tc-DTPA for detection and localization of site of acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Dayem, H.; Owuwanne, A.; Nawaz, K.; Kouris, K.; Higazy, E.; Mahajan, K.; Ericsson, S.; Awdeh, M.

    1988-05-01

    Intravenously injected /sup 99m/Tc-DTPA was evaluated in 64 patients for its efficiency in detecting and localizing sites of acute upper and lower gastrointestinal (G.I.) bleeding. These studies were correlated with endoscopic and surgical findings. There were 34 bleeders and 30 non bleeders giving a sensitivity of 90%, specificity of 82% and accuracy of 86%. Of these, 49 were upper G.I. studies (stomach 21 and duodenum 28) and 15 were lower G.I. studies (small intestine 8, large bowel 7). Of the 49 upper G.I. studies, 27 showed active bleeding while 22 showed no bleeding at the time of the study resulting in a sensitivity of 87.5%, specificity of 76% and accuracy of 82%. Of the 15 lower G.I. studies, 7 were bleeders while 8 were non bleeders. All the lower G.I. bleeding sites were accurately localized with the /sup 99m/Tc-DTPA. An incidental finding of these studies was the localization of /sup 99m/Tc-DTPA in the site of inflammatory and malignant lesions of the G.I. tract. Of the 64 studies, 18 inflammatory and malignant lesions were detected with the IV injected /sup 99m/Tc-DTPA; 10 were bleeders while 8 were non bleeders. Image subtraction of early from delayed images was helpful to differentiate bleeding from non bleeding cases in this last group of studies.

  9. The use of 99mTc-DTPA for detection and localization of site of acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.; Owuwanne, A.; Nawaz, K.; Kouris, K.; Higazy, E.; Mahajan, K.; Ericsson, S.; Awdeh, M.; Kuwait Univ. Dept. of Surgery)

    1988-01-01

    Intravenously injected 99m Tc-DTPA was evaluated in 64 patients for its efficiency in detecting and localizing sites of acute upper and lower gastrointestinal (G.I.) bleeding. These studies were correlated with endoscopic and surgical findings. There were 34 bleeders and 30 non bleeders giving a sensitivity of 90%, specificity of 82% and accuracy of 86%. Of these, 49 were upper G.I. studies (stomach 21 and duodenum 28) and 15 were lower G.I. studies (small intestine 8, large bowel 7). Of the 49 upper G.I. studies, 27 showed active bleeding while 22 showed no bleeding at the time of the study resulting in a sensitivity of 87.5%, specificity of 76% and accuracy of 82%. Of the 15 lower G.I. studies, 7 were bleeders while 8 were non bleeders. All the lower G.I. bleeding sites were accurately localized with the 99m Tc-DTPA. An incidental finding of these studies was the localization of 99m Tc-DTPA in the site of inflammatory and malignant lesions of the G.I. tract. Of the 64 studies, 18 inflammatory and malignant lesions were detected with the IV injected 99m Tc-DTPA; 10 were bleeders while 8 were non bleeders. Image subtraction of early from delayed images was helpful to differentiate bleeding from non bleeding cases in this last group of studies. (orig.)

  10. Glomerular filtration rate estimated from the uptake phase of 99mTc-DTPA renography in chronic renal failure

    DEFF Research Database (Denmark)

    Petersen, L J; Petersen, J R; Talleruphuus, U

    1999-01-01

    The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea.......The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea....

  11. Dynamic 99mTc-DTPA radioaerosol lung scanning for the evaluation of alveolar-capillary barrier permeability

    International Nuclear Information System (INIS)

    Maini, C.L.; Marchetti, L.; Bonetti, M.G.; Giordano, A.; Pistelli, R.; Antonelli Incalzi, R.

    1987-01-01

    Pulmonary clearance of small droplet 99m Tc-DTPA radioaerosol was studied in 100 patients (12 normal subjects, N; 10 asymptomatic healthy smoker, FA; 31 patients with interstitial lung diseases, IP; 47 patients with chronic obstructive lung disease, BPCO). The first seven minutes of clearance were described with the function At=Ao*exp(-K*t) and the time constant K was considered representative of the 99m Tc-DTPA clearance rate and hence of the alveolar-capillary barrier permeability. Groups FA, IP and BPCO showed a significant (p 99m Tc-DTPA dynamic lung scanning is an easy, non-invasive method to assess derangements of alveolar-capillary barrier permeability secondary to epithelial damage; 2) permeability increase is a very early effect of cigarette smoke damafe to the epithelium; 3) other mechanisms of epithelial injury are present in diffuse lung disease; 4) while the clinical role of this new pathophysiological test is not yet clear, it is likely that it may become a very early marker of pulmonary epithelial damage in diffuse lung disease

  12. Pulmonary clearance of {sup 99m}Tc-DTPA in experimental surfactant dysfunction treated with surfactant installation

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, K.; John, J.; Lachmann, B.; Robertson, B.; Wollmer, P.

    1997-02-01

    Background: Breakdown of the alveolo-capillary barrier is a characteristic feature of respiratory distress syndrome. Restoration of alveolo-capillary barrier function may be an important aspect of surfactant replacement therapy. We examined the effect of surfactant installation on alveolo-capillary barrier function in an experimental model of surfactant dysfunction by measuring pulmonary clearance of {sup 99m}Tc-DTPA. Methods: Nineteen rabbits were tracheotomized and mechanically ventilated. Surfactant dysfunction was induced by administration of a synthetic detergent in aerosol form. Detergent was given to 13 rabbits; seven rabbits were then treated with installation of natural surfactant, whereas six rabbits received saline. Six rabbits were used as untreated controls. An aerosol of {sup 99m}Tc-DTPA was administered to all animals and the pulmonary clearance was measured with a gamma camera. Results: {sup 99m}Tc-DTPA cleared from the lungs with a half-life of 71{+-}22 min in the control animals, 21.4{+-}7.4 min in the surfactant-treated animals and 5.8{+-}1.5 min in the saline-treated animals. The difference in half-life between groups was highly significant (P<0.001). There was no change in arterial oxygenation or compliance in controls or in animals treated with saline. In animals treated with surfactant, a small transient reduction in arterial oxygen tension and a more long-standing reduction in compliance were observed. Conclusion: Surfactant treatment thus significantly attenuated the effect of detergent treatment but did not restore alveolo-capillary transfer of {sup 99m}Tc-DTPA to normal. (AU) 26 refs.

  13. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  14. Sonography and dynamic scintigraphy with 99mTc-DTPA in children with nephrotic syndrome

    International Nuclear Information System (INIS)

    Bliznakova, D.; Klisarove, A.

    2000-01-01

    The aim of the study is to assay the clinical application of kidney sonography and dynamic scintigraphy with 99m Tc-DTPA in children presenting nephrotic syndrome. A total of 32 children (mean age 9.5±1.2) are covered by the study, with the most important laboratory investigations being performed. All patients undergo abdominal sonography and dynamic kidney scintigraphy following iv administration of 100 μC/kg 99m Tc-DTPA, and glomerular filtration clarence (GFR) measured by the method of full and empty syringe activity. The functional curves are also shown. In children with primary nephrotic syndrome the sonographic imaging reveals enlarged kidney size and enhanced sonogeneity of parenchyma in the first stage. In patients with secondary nephrotic syndrome increased kidney size is likewise observed with enhanced sonogeneity of parenchyma in second stage and unclear visualization of pyramids. In children with idiopathic nephrotic syndrome the scintigraphic data confirm the enlarged kidneys with moderately increased values of GFR. In the mixed forms of nephrotic syndrome the kidneys preserve their moderate enlargement against the background of heterogeneous GFR values. In 5 patients the functional curves show kidney excretion impairment. The study confirms that sonographic imaging correlates well with the dynamic scintigraphic 99m Tc-DTPA imaging in children with nephrotic syndrome. The functional curves and GFR values promote accurate diagnosing and monitoring of the dynamic pathological processes. (author)

  15. Effects of sustained exercise on pulmonary clearance of aerosolized 99mTc-DTPA

    International Nuclear Information System (INIS)

    Lorino, A.M.; Meignan, M.; Bouissou, P.; Atlan, G.

    1989-01-01

    The effects of intensive prolonged exercise on the pulmonary clearance rate of aerosolized 99m Tc-labeled diethylenetriaminepentaacetate ( 99m Tc-DTPA) and pulmonary mechanics were studied in seven healthy nonsmoking volunteers. 99m Tc-DTPA clearance and pulmonary mechanics (lung volumes and compliance) were assessed before and after 75 min of constant-load exercise performed on a treadmill, corresponding to 75% of maximal O 2 uptake. Because both clearance measurements were made in similar conditions of pulmonary blood flow, respiratory rate, and tidal volume, changes in clearance rate can be assumed to represent changes of alveolar epithelial permeability. After exercise, total, apical, and basal clearance were significantly increased (P less than 0.01, 0.05, and 0.05, respectively) and the increases in total clearance and tidal volume observed during exercise were significantly correlated (P less than 0.05). In contrast, no significant change was found in pulmonary mechanics. These results show that prolonged intensive exercise induces an increase in epithelial permeability, which appears to be related to the mechanical effects of sustained increased ventilation. Because no change was evidenced in pulmonary volumes or in lung elasticity, our results suggest that this increase may result from alteration of the intercellular tight junctions rather than from a surfactant deficiency

  16. Synthesis and biological assessment of folate-accepted developer (99m)Tc-DTPA-folate-polymer.

    Science.gov (United States)

    Chen, Fei; Shao, Kejing; Zhu, Bao; Jiang, Mengjun

    2016-05-15

    A novel cancer-targetable folate-poly(2-hydroxyethyl methacrylate) (PFDH) copolymer containing DTPA segment was prepared by conventional chemical synthesis and labeled with (99m)Tc subsequently. The (99m)Tc-labled PFDH could be produced easily with high radiochemical yield of 91% and radiochemical purity of 95%. The LogP octanol-water value for the (99m)Tc-labled PFDH was -2.19 and the radiotracer was stable in phosphate-buffered saline and human serum for 2h (>95% in PBS or ∼90% in human serum). To investigate (99m)Tc-labled PFDH tumor targeting, the in vitro and in vivo stability, cell uptake, in vivo biodistribution, and SPECT imaging were evaluated, respectively. These preliminary results strongly suggest that the novel folate conjugated dendrimer maybe developed to be potential for delivery of therapeutic radionuclides. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Clinical evaluation of renal scintigram with 123I-OIH and sup(99m)Tc-DTPA in renal transplantation

    International Nuclear Information System (INIS)

    Ishibashi, Akira; Fujino, Awato; Ikeda, Shigeru; Ishii, Katsumi; Nakazawa, Keiji

    1983-01-01

    We have carried out 85 renal scintigrams on the 29 renal transplants last 6 months. Clinical usefulness of 123 I-IIH (ortho-iodohippurate) specially prepared compared with that of sup(99m)Tc-DTPA. The parameters of the vascular phase, perfusion index (PI) and (mean) transit time (TT), for the 123 I-OIH and sup(99m)Tc-DTPA renal scintigrams, were almost identical. Therefore it might be thought that renal circulation of 123 I-OIH is similar to that of sup(99m)Tc-DTPA. Moreover 123 I-OIH can afford us specific information on the exretory phase. The complicated renal transplants are well differentiated from normal functioning ones by B/K ratio of 123 I-OIH. B/K ratio is one of the parameters for the excretory phase. 123 I-OIH could be a useful agent for the clinical evaluation after renal transplantation. (author)

  18. Pulmonary clearance of sup 99m Tc-DTPA aerosol in patients with progressive systemic scleroderma

    Energy Technology Data Exchange (ETDEWEB)

    Tateno, Madoka; Nakano, Akihiko; Hasegawa, Akira; Watanabe, Naoyuki; Oriuchi, Noboru; Inoue, Tomio; Endo, Keigo (Gunma Univ., Maebashi (Japan). School of Medicine); Sasaki, Yasuhito

    1992-05-01

    Alveolar epithelial permeability was assessed in 32 patients with progressive systemic scleroderma (PSS), using {sup 99m}Tc-DTPA aerosol. Immediately after the inhalation of {sup 99m}Tc-DTPA aerosol for 3 to 6 minutes under normal tidal breathing, lung was imaged sequentially for 30 minutes from the posterior by a gamma camera and exponential fitting was processed on the time activity curve. T{sub 1/2} (min) was used as a parameter for the evaluation of permeability of alveolar epithelium. Patients with collagen disease showed shorter T{sub 1/2} (T{sub 1/2}=43.7{+-}23.8 min) than the normal volunteers (T{sub 1/2}=76.8{+-}8.7 min). No significant difference was observed between patients with or without interstitial changes on the chest CT. Significant correlation was not observed between T{sub 1/2} and %VC or %DLco. In 8 cases, studies were repeated in the interval of 3 to 19 months. Improvement of T{sub 1/2} was seen in 4 cases, independent of CT findings. These results suggest that {sup 99m}Tc-DTPA aerosol clearance study provides information independent from other lung examinations, and may be useful for the assessment of lung interstitial changes in patients with PSS. (author).

  19. 99mTc-DTPA Pulmonary Clearance in Normals

    International Nuclear Information System (INIS)

    Chung, Soo Kyo; Yang, Woo Jin; Sohn, Hyung Sun; Shinn, Kyung Sub; Bahk, Yong Whee

    1994-01-01

    Pulmonary clearance of 99m Tc-DTPA(PCD) has been used for the measurement of pulmonary epithelial permeability. It has been reported to be increased not only in variety of pulmonary diseases including ARDS, interstitial fibrosis, and smokers, but also in normal subjects on positive end expiratory pressure respirator, or after exercise. It was also noted that decrease of pulmonary blood flow due to pulmonary arterial obstruction results in delayed PCD. Normal range of PCD varies with institutes. We prospectively measured PCD in 17 normals (5 males and 12 females) consisted of staffs and trainees in the department of radiology of Kangnam St, Marys hospital using original Bark Nebulizer (India). Age ranged from 32 to 43 years. 370 MBq of 99m Tc-DTPA was inhaled in supine position and supine posterior images were subsequently obtained with 1 min/frame, 64 X 64 matrix and word mode for 30 min. Regions of interest. Were set on each lung, whole lungs, and upper, middle and lower thirds of right lung, respectively. Best fit regression curve was obtained by least square method from initial 7 min after peak activity on each curve and time for half clearance of maximum activity (tl/2) was calculated. Mean tl/2 was 51 ± 11.2 min for whole lung. There was no significant difference between tl/ 2 of right and left lungs. Initial uptake was higher in the lower third and tl/2 was shorter in the lower third than in the upper third(P<0.05). We reviewed several reports on PCD and compared our data with the others. In this study, faster clearance in the lower third may be due to the position imaged with or the environment the subjects belong to, and further investigation is under way.

  20. Characterization of the radioaerosol sup(99m)Tc-DTPA produced by different nebulizers

    International Nuclear Information System (INIS)

    Medeiros, R.B.; Nery, L.E.; Tabacniks, M.H.

    1991-01-01

    Our aim was to characterize the aerosol produced by different nebulizers through the use of sup(99m)Tc-DTPA normally applied in pulmonar ventilation studies in nuclear medicine. We have found the mass distribution's MMD and the geometric standard deviation for this type of radioaerosol. (author)

  1. Value of Tc99m-DTPA alveolar permeability in lung involvement detection of patients with HIV infection

    International Nuclear Information System (INIS)

    Massardo Vega, Teresa; Jofre Manieu, Maria Josefina; Cabello Araya, Hernan; Sepulveda Carvajal, Cecilia; Ruiz Carmona, Mauricio; Moyano Schlegel, Leonor; Fica Cubillos, Alberto; Alay Perez, Rita

    2001-01-01

    We studied 35 HIV patients in order to know the value of Tc99mDTPA in the assessment of pulmonary lung involvement, especially pneumocystis carinii (PC) infection. Lung DTPA clearance measures increased alveolar permeability. Twenty patients with respiratory symptoms were included, 4 with systemic symptoms and also 11 asymptomatics, with similar immune condition (CD4 lymphocytes <400) as a control group. Smoking habit was suspended prior the test. Clinical follow up, chest film, induced sputum and/or fibrobronchoscopy were obtained. There was histological confirmation of PC presence or absence in 16 symptomatics and 3 asymptomatics. DTPA sensitivity for PC detection was 78%, specificity 40% and accuracy 58%; the values were 85%, 60% and 79%, respectively, for inflammatory lung processes. There were 4/6 cases false positive for PC detection with respiratory features explaining DTPA abnormalities. Concluding, Tc99m-DTPA is sensitive but not specific for detecting PC pneumonia but its value is higher for pulmonary inflammatory processes (Au)

  2. The usefulness of sup(99m)Tc-DTPA renogram in the functional and diagnostic evaluations of chronic renal insufficiency in children

    International Nuclear Information System (INIS)

    Matsueda, Yoriko; Hiraiwa, Mikio; Meguro, Hidenori; Fujii, Ryochi

    1980-01-01

    As there are some difficulties in the performance of renal biopsy and intravenous pyelography is of little use in children with chronic renal insufficiency, we evaluated the usefulness of sup(99m)Tc-DTPA renogram in two children. The causes of the renal insufficiency presented were obstructive congenital anomalies and chronic pyelonephritis in one patient and polycystic kidneys in the other. As expected, intravenous pyelography poorly visualized in the upper urinary tracts of both the cases examined. sup(99m)Tc-DTPA renogram gave us distinct image for the diagnosis of the kidneys and urinary tracts, and the individual renal functions were clarified as well. It was apparently superior to the combined use of sup(99m)Tc-DMSA renoscintigram and 131 I-Hippuran renogram in both the imaging and functional evaluations. In such cases as are reported herein, sup(99m)Tc-DTPA renogram might be a useful alternative to several other diagnostic tests. (author)

  3. Baseline Tc-99m DTPA renal scintigraphy as a predictor of outcome in children with urinary tract infection

    Energy Technology Data Exchange (ETDEWEB)

    Yun, J. G.; An, Y. S.; Lee, M. H.; Cho, C. W.; Yun, S. N.; Pai, G. S [Ajou University Medical Center, Suwon (Korea, Republic of)

    2004-07-01

    Tc-99m DTPA renal scintigraphy is useful in detecting urinary tract obstruction in patients with urinary tract infection (UTI). We evaluated the prognostic significance of baseline Tc-99m DTPA renal scintigraphy in children with UTI. Among children, who underwent both baseline/follow-up Tc-99m DMSA scintigraphies and baseline Tc-99m DTP A scintigraphy for evaluation of UTI, 32 patients with unilateral cortical defects on baseline Tc-99m DMSA scintigraphy were included in the study. The outcome of cortical defects was evaluated on follow-up Tc-99m DMSA scintigraphy by visual analysis. ROIs were drawn on the Tc-99m DPTA scintigraphy for calculation of ipsilateral to contralateral kidney ratio (ICR) at blood flow phase (< 60s, BFP) and cortical uptake phase (1-5 min, CUP). Median follow-up period of Tc-99m DMSA scintigraphy was 3.2 months (1.4 - 14 months). There were 24 patients with healing cortical defects and 8 with cortical scarring. Average ICRs of patients with healing defects were 1.11 {+-} 0.18 (0.44 - 1.57) at BFP and 0.97 {+-} 0.21 (0.31 - 1.28) at CUP, while those of patients with cortical scarring were 0.97 {+-} 0.47 (0.21 - 0.89) at BFP and 0.75 {+-} 0.49 (0.19 - 1.65) at CUP. ICR more than 0.9 was determined as a good prognostic indicator. The sensitivity, specificity, positive predictive value, and negative predictive value of ICR was 83.3%, 100%, 100% and 66.7% at BFP, and 79.0%, 62.5%, 86.4% and 50.0% at CUP. Ipsilateral to contralateral kidney ratio on baseline Tc-99m DPTA renal scintigraphy, especially at blood flow phase, is helpful in predicting outcome of children with UTI.

  4. Baseline Tc-99m DTPA renal scintigraphy as a predictor of outcome in children with urinary tract infection

    International Nuclear Information System (INIS)

    Yun, J. G.; An, Y. S.; Lee, M. H.; Cho, C. W.; Yun, S. N.; Pai, G. S

    2004-01-01

    Tc-99m DTPA renal scintigraphy is useful in detecting urinary tract obstruction in patients with urinary tract infection (UTI). We evaluated the prognostic significance of baseline Tc-99m DTPA renal scintigraphy in children with UTI. Among children, who underwent both baseline/follow-up Tc-99m DMSA scintigraphies and baseline Tc-99m DTP A scintigraphy for evaluation of UTI, 32 patients with unilateral cortical defects on baseline Tc-99m DMSA scintigraphy were included in the study. The outcome of cortical defects was evaluated on follow-up Tc-99m DMSA scintigraphy by visual analysis. ROIs were drawn on the Tc-99m DPTA scintigraphy for calculation of ipsilateral to contralateral kidney ratio (ICR) at blood flow phase (< 60s, BFP) and cortical uptake phase (1-5 min, CUP). Median follow-up period of Tc-99m DMSA scintigraphy was 3.2 months (1.4 - 14 months). There were 24 patients with healing cortical defects and 8 with cortical scarring. Average ICRs of patients with healing defects were 1.11 ± 0.18 (0.44 - 1.57) at BFP and 0.97 ± 0.21 (0.31 - 1.28) at CUP, while those of patients with cortical scarring were 0.97 ± 0.47 (0.21 - 0.89) at BFP and 0.75 ± 0.49 (0.19 - 1.65) at CUP. ICR more than 0.9 was determined as a good prognostic indicator. The sensitivity, specificity, positive predictive value, and negative predictive value of ICR was 83.3%, 100%, 100% and 66.7% at BFP, and 79.0%, 62.5%, 86.4% and 50.0% at CUP. Ipsilateral to contralateral kidney ratio on baseline Tc-99m DPTA renal scintigraphy, especially at blood flow phase, is helpful in predicting outcome of children with UTI

  5. 99mTc-DTPA renography before and after extracorporeal shock wave lithotripsy for renal calculi

    International Nuclear Information System (INIS)

    Ohtake, Eiji; Murata, Hajime; Kanemura, Mikio; Yokoyama, Masao

    1988-01-01

    This study was undertaken to evaluate 99m Tc-DTPA renography before and after extracorporeal shock wave lithotripsy (ESWL). Twelve patients with renal calculi were examined in this study. In three patients, bilateral kidneys were treated with ESWL. Sequential renal images of the vascular phase, and the functional and excretory phases were taken using a gamma camera (ZLC 7500, Siemens), after intravenous injection of 555 MBq of 99m Tc-DTPA. Renograms were generated using data stored every 10 seconds for a period of 30 minutes by computer (Scintipac-2400, Shimadzu). Some treated kidneys were enlarged and/or showed uniform retention of radioactivity on sequential images, within a week after ESWL. Renogram patterns after ESWL were varied in each patient. The renogram findings after ESWL seemed to be affected by the presence or absence of stone fragments in the urinary tract. (author)

  6. Impact of Gate 99mTc DTPA GFR, Serum Creatinine and Urea in Diagnosis of Patients with Chronic Kidney Failure

    Science.gov (United States)

    Miftari, Rame; Nura, Adem; Topçiu-Shufta, Valdete; Miftari, Valon; Murseli, Arbenita; Haxhibeqiri, Valdete

    2017-01-01

    Aim: The aim of this study was determination of validity of 99mTcDTPA estimation of GFR for early detection of chronic kidney failure Material and methods: There were 110 patients (54 males and 56 females) with kidney disease referred for evaluation of renal function at UCC of Kosovo. All patients were included in two groups. In the first group were included 30 patients confirmed with renal failure, whereas in the second group were included 80 patients with other renal disease. In study were included only patients with ready results of creatinine, urea and glucose in the blood serum. For estimation of GFR we have used the Gate GFR DTPA method. The statistical data processing was conducted using statistical methods such as arithmetic average, the student t-test, percentage or rate, sensitivity, specificity and accuracy of the test. Results: The average age of all patients was 36 years old. The average age of female was 37 whereas of male 35. Patients with renal failure was significantly older than patients with other renal disease (p<0.005). Renal failure was found in 30 patients (27.27%). The concentration of urea and creatinine in blood serum of patients with renal failure were significantly higher than in patients with other renal disease (P< 0.00001). GFR in patients with renal failure were significantly lower than in patients with other renal disease, 51.75 ml/min (p<0.00001). Sensitivity of uremia and creatininemia for detection of renal failure were 83.33%, whereas sensitivity of 99mTcDTPA GFR was 100%. Specificity of uraemia and creatininemia were 63% whereas specificity of 99mTcDTPA GFR was 47.5%. Diagnostic accuracy of blood urea and creatinine in detecting of renal failure were 69%, whereas diagnostic accuracy of 99mTcDTPA GFR was 61.8%. Conclusion: Gate 99mTc DTPA scintigraphy in collaboration with biochemical tests are very sensitive methods for early detection of patients with chronic renal failure. PMID:28883673

  7. Dynamic /sup 99m/Tc-DTPA radioaerosol lung scanning for the evaluation of alveolar-capillary barrier permeability

    Energy Technology Data Exchange (ETDEWEB)

    Maini, C L; Marchetti, L; Bonetti, M G; Giordano, A; Pistelli, R; Antonelli Incalzi, R

    1987-01-01

    Pulmonary clearance of small droplet /sup 99m/Tc-DTPA radioaerosol was studied in 100 patients (12 normal subjects, N; 10 asymptomatic healthy smoker, FA; 31 patients with interstitial lung diseases, IP; 47 patients with chronic obstructive lung disease, BPCO). The first seven minutes of clearance were described with the function At=Ao*exp(-K*t) and the time constant K was considered representative of the /sup 99m/Tc-DTPA clearance rate and hence of the alveolar-capillary barrier permeability. Groups FA, IP and BPCO showed a significant (p<0.05) or a highly significant (p<0.01) increase in permeability when compared to group N. No correlation was found between permeability and bronchial obstraction tests. The following conclusions were drawn: 1) /sup 99m/Tc-DTPA dynamic lung scanning is an easy, non-invasive method to assess derangements of alveolar-capillary barrier permeability secondary to epithelial damage; 2) permeability increase is a very early effect of cigarette smoke damafe to the epithelium; 3) other mechanisms of epithelial injury are present in diffuse lung disease; 4) while the clinical role of this new pathophysiological test is not yet clear, it is likely that it may become a very early marker of pulmonary epithelial damage in diffuse lung disease. 35 refs.

  8. Alteration of renal function in a control animal. Finding by "9"9"mTc - DTPA renogram

    International Nuclear Information System (INIS)

    Portillo, M.G.; Tesán, F.C.; Zubillaga, M.B.; Salgueiro, M.J.

    2015-01-01

    The use of small animal imaging in research protocols allowed the identification of an outlier animal. The renogram with "9"9"mTc-DTPA showed renal pathology in an animal from the control group. (authors) [es

  9. Evaluation of the use of technetium Tc 99m diethylenetriamine pentaacetic acid and technetium Tc 99m dimercaptosuccinic acid for scintigraphic imaging of the kidneys in green iguanas (Iguana iguana).

    Science.gov (United States)

    Greer, Leah L; Daniel, Gregory B; Shearn-Bochsler, Valerie I; Ramsay, Edward C

    2005-01-01

    To evaluate the use of scintigraphy involving technetium Tc 99m diethylenetriamine pentaacetic acid ((99m)Tc-DTPA) or technetium Tc 99m dimercaptosuccinic acid ((99m)Tc-DMSA) for the determination of kidney morphology and function in green iguanas (Iguana iguana). 10 healthy iguanas weighing >1.6 kg. Renal scintigraphy was performed by use of (99m)Tc-DTPA in 6 of the iguanas and by use of (99m)Tc-DMSA in all 10 iguanas. After the injection of (99m)Tc-DMSA, scans were performed for each iguana at intervals during a 20-hour period. Renal biopsies were performed in all 10 iguanas after the final scintigraphic evaluation. In iguanas, the use of (99m)Tc-DTPA for renal scintigraphy was nondiagnostic because of serum protein binding and poor renal uptake of the isotope; mean +/- SD (99m)Tc-DTPA bound to serum proteins was 48.9 +/- 9.9%. Renal uptake of (99m)Tc-DMSA produced distinct visualization of both kidneys. Renal uptake and soft tissue clearance of (99m)Tc-DMSA increased over the 20-hour imaging period; mean +/- SD renal uptake of (99m)Tc-DMSA was 11.31 +/- 3.06% at 20 hours. In each of the 10 iguanas, ultrasonographic and histologic examinations of biopsy specimens from both kidneys revealed no abnormalities. Results indicate that the kidneys of iguanas can be evaluated scintigraphically by use of (99m)Tc-DMSA; this technique may be potentially useful for the diagnosis of renal failure in iguanas.

  10. Evaluation of liver function in carbon tetrachloride-damaged rabbits by dynamic SPECT. Comparison of 99mTc-GSA and 99mTc-Sn colloid

    International Nuclear Information System (INIS)

    Kiuchi, Takaaki; Kawasaki, Yukiko; Hino, Ichirou; Kojima, Kanji; Ohkawa, Motoomi; Tanabe, Masatada; Tamai, Toyosato.

    1994-01-01

    Technetium-99m-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) is a new ligand that binds specifically to asialoglycoprotein receptors in hepatocytes. We performed liver dynamic SPECT using 99m Tc-GSA and 99m Tc-Sn colloid in nine normal control rabbits and 17 chronically CCl 4 -damaged rabbits (total 29 examinations), and also performed liver function tests (ICGR 15 , Alb, etc). Using the obtained dynamic SPECT data, we analyzed the liver kinetics of 99m Tc-Sn colloid using a one-compartment model (hepatic blood flow [K]) and 99m Tc-GSA using a two-compartment model (hepatic blood flow and receptor binding [K 1 ], catabolism [K 2 ]). As the CCl 4 -treated period increased, K 1 decreased most significantly. K 1 showed the most statistically significant correlation with the results of liver function tests, ICGR 15 (p 1 showed a correlation with the hepatic fibrosis of the HAI score. From the present results, liver dynamic SPECT using 99m Tc-GSA may be said to provide a novel method for the evaluation of hepatic functional reserve. (author)

  11. Re-estimation of renal function with 99mTc-DTPA by the Gates' method

    International Nuclear Information System (INIS)

    Itoh, Kazuo; Arakawa, Masanori

    1987-01-01

    We analyzed a regression equation between percent total renal uptake (%TRU) of 99m Tc-DTPA and creatinine clearance (Ccr) by the Gates' method in 82 patients. 1) The following regression equations between measured renal depth on CT scan and (weight in kg)/(height in cm) in Japanese were obtained; Right in both kidneys = 13.6361 · (W/H) 0.6996 (n = 217, r = 0.86691, p 0.7554 (n = 224, r = 0.8822, p 0.8099 (n = 27, r = 0.9515, p 0.6997 (n = 21, r = 0.9213, p 2 ) = 13.15 · %TRU 0.787 (n = 86, r = 0.820, p 0.753 (n = 40, r = 0.754). The Gates' method is very convenient for an immediate estimation of glomerular filtration rate (GFR) after renal scintigraphy using 99m Tc-DTPA. However, the correlation coefficient was not high as compared to the Gates' results. The equation which was reported by Gates' is not necessarily adaptable in routine study. Each facility which uses the Gates' method for estimating GFR should obtain the corrected regression equation between %TRU and Ccr. (author)

  12. /sup 99m/Tc-DTPA renography before and after extracorporeal shock wave lithotripsy for renal calculi

    Energy Technology Data Exchange (ETDEWEB)

    Ohtake, Eiji; Murata, Hajime; Kanemura, Mikio; Yokoyama, Masao

    1988-09-01

    This study was undertaken to evaluate /sup 99m/Tc-DTPA renography before and after extracorporeal shock wave lithotripsy (ESWL). Twelve patients with renal calculi were examined in this study. In three patients, bilateral kidneys were treated with ESWL. Sequential renal images of the vascular phase, and the functional and excretory phases were taken using a gamma camera (ZLC 7500, Siemens), after intravenous injection of 555 MBq of /sup 99m/Tc-DTPA. Renograms were generated using data stored every 10 seconds for a period of 30 minutes by computer (Scintipac-2400, Shimadzu). Some treated kidneys were enlarged and/or showed uniform retention of radioactivity on sequential images, within a week after ESWL. Renogram patterns after ESWL were varied in each patient. The renogram findings after ESWL seemed to be affected by the presence or absence of stone fragments in the urinary tract.

  13. Assessment of renal impairment by non-contrast-enhanced conventional magnetic resonance imaging. Comparison with 99mTc-DTPA renography

    International Nuclear Information System (INIS)

    Hidaka, Fumitaka; Amano, Yasuo; Takahama, Katsuya; Takagi, Ryo; Murakami, Ryusuke; Onozawa, Shiro; Kumita, Shinichiro

    2011-01-01

    The aim of this study was to determine whether non-contrast-enhanced magnetic resonance imaging (MRI) can detect three levels of renal impairment by evaluating the differences and agreement with 99m Tc-diethylenetriamine pentaacetic acid (DTPA) renography. A total of 28 patients with kidney disease were enrolled in the study. MRI findings, including visual corticomedullary differentiation (CMD) on T1- and T2-weighted imaging (T1WI, T2WI), cortical irregularity, the number of renal cysts, and the volume of the kidney, were evaluated for individual kidneys and pairs of kidneys. The differences and agreement between MRI findings and the three levels of renal impairment based on the glomerular filtration rate (GFR) measured using 99m Tc-DTPA renography were analyzed. All MRI findings except the number of renal cysts in pairs of kidneys were consistent with the patient's classification. The agreement between the patient's classifications based on GFR and that based on the visual CMD on T1WI and T2WI was almost perfect or substantial in both individual kidneys and pairs of kidneys. Non-contrast-enhanced MRI was capable of distinguishing three levels of renal function, including serious renal impairment. (author)

  14. Clinical evaluation of the hepatic hemodynamics using [sup 99m]Tc-DTPA-HSA scintiangiography in patients with viral chronic liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Kentaro [Toho Univ., Tokyo (Japan). School of Medicine

    1994-01-01

    [sup 99m]Tc-DTPA-HSA scintiangiography was performed in 81 cases of viral chronic liver disease, and a time-activity curve (TAC) of the liver was classified into three types (I, II, III). Furthermore, portal component of the total hepatic blood flow was calculated. The results were compared with those of [sup 99m]Tc-phytate scintigraphy. The TAC type changed from I through III according to the histological development of the liver. Esophageal varices was seen frequently in patients of type III, and in none of type I. The portal component significantly decreased in the order of chronic hepatitis without lobular distortion, with lobular distortion, and liver cirrhosis. However, the portal component obtained by using [sup 99m]Tc-phytate did not show a significant difference between chronic hepatitis without and with lobular distortion. [sup 99m]Tc-DTPA-HSA scintigraphy was thought to be a useful diagnostic procedure in patients with chronic liver disease. (author).

  15. Study of technetium behaviour in radiopharmaceuticals. Characterization of sup(99m)Tc-pyrophosphate, sup(99m)Tc-dimercaptosuccinate, sup(99m)Tc-diethylenetriaminepentaacetate complexes and sup(99m)Tc-colloidal rhenium sulphide

    International Nuclear Information System (INIS)

    Saccavini, J.-C.

    1980-12-01

    The chemistry of technetium in extremely dilute solution was approached through the study of three complexing agents and a colloid. By the application of high-performance chromatographic techniques to the analysis of (Tc-pyro), (Tc-DTPA), (Tc-DMSA) complexes it was possible to isolate one or more chelates from a single complexing agent. Addition of pertechnetates to a solution of sodium pyrophosphates and stannous chloride at neutral pH leads to the formation of two complexes, both highly osteotropic. By the use of sup(117m)Sn it was shown that tin employed as reducing agent enters into the composition of one of the two complexes, either of which may be obtained preferentially by varying the (Sn)/(pyro) ratio. With technetium at acid pH (2.5) DMSA gives one or more chelates according to the concentration of the reagents present. DTPA with technetium at neutral pH gives a single complex for which a structure is proposed. The addition of calcium, indispensable for DTPA injection, leads to the appearance of a second bimetallic complex in very much smaller proportions than the first. The size distribution of some colloids was studied by ultrafiltration and permeation on gel. The preparation of colloidal rhenium sulphide and the technetium labelling conditions needed to obtain a very fine colloid were developed. The behaviour of technetium in the presence of colloidal rhenium sulphide and tin pyrophosphate was followed by sup(99m)Tc - sup(186)Re and sup(99m)Tc - sup(117m)Sn double-labelling tests. One reduced technetium fraction associates with the hydrolysed tin, the other follows the rhenium sulphide [fr

  16. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  17. Influence of hilar deposition in the evaluation of the alveolar epithelial permeability on 99mTc-DTPA aerosol inhaled scintigraphy

    International Nuclear Information System (INIS)

    Ogi, Shigeyuki; Uchiyama, Mayuki; Fukuda, Kunihiko; Urashima, Mitsuyoshi; Gotoh, Eisuke; Fukumitsu, Nobuyoshi

    2009-01-01

    We investigated whether hilar radioaerosol deposition affects the clearance rate of technetium-99m-labeled diethylenetriaminepentaacetic acid ( 99m Tc-DTPA) from peripheral alveolar regions. A total of 38 patients underwent 99m Tc-DTPA inhalation lung scintigraphy. Six region of interest (ROI) patterns were adopted: ROI 1 was outlined around the entire hemithorax, and ROIs 2-6 were outlined around the hemithorax but excluded square ROIs of different size in the hilar region. Half-times (T 1/2 ) were calculated with time-activity curves using one-compartment and two-compartment analyses. The T 1/2 of ROIs 1-5 were plotted against the T 1/2 of ROI 6, and regression lines were obtained with the least-squares method. The absolute values of the differences between surveyed values and regression line were calculated. The Wilcoxon test for trend and a single linear regression model were used to determine statistical significance. There were significant reductions in the absolute values of the differences between surveyed values and regression line from ROIs 1-5 by one-component analysis and the fast component of two-compartment analysis (P 99m Tc-DTPA from the alveoli in damaged lungs. The hilar region should be excluded from ROIs when alveolar epithelial permeability is evaluated. (author)

  18. Study on 99Tcm-DTPA-HSA as a new blood pool scanning agent

    International Nuclear Information System (INIS)

    Liu Yunzhong; Zhang Zheng; Wu Qingwen

    1994-01-01

    The biological behavior of 99 Tc m -DTPA-HSA, 99 Tc m -RBC(in vivo) and 99 Tc m -HSA are studied in rabbits. Excellent cardiac blood-pool images are obtained by 99 Tc m -DTPT-HSA and 99 Tc m -RBC. Biodistribution studies show that 99 Tc m -DTPA-HSA has less accumulation than 99 Tc m -RBC in lungs and liver. They have similar count ratio of the cardiac blood pool to whole body. Ratio of heart/liver is 0.85 for 99 Tc m -DTPA-HSA, 0.95 for 99 Tc m -RBC and 0.62 for 99 Tc m -HSA. 99 Tc m -DTPA-HSA is a promising agent. It is readily performed only by single in vivo injection

  19. An experimental model for measuring gastrointestinal bleeding rate using Tc-99m DTPA in rabbits

    International Nuclear Information System (INIS)

    Owunwanne, A.; Abdel-Dayem, H.M.; Sadek, S.; Yakoub, T.; Mahajan, K.K.; Ericsson, S.B.

    1987-01-01

    An animal experimental model to measure the rate of gastrointestinal bleeding rate in a rabbit using Tc-99m DTPA is described. It was possible to detect a bleeding rate of 0.1 ml/min. However, the model could not be used to calculate the minimum amount of radioactivity needed to detect the bleeding site. (orig.) [de

  20. Usefulness of 99mTc-DTPA cisternography and brain computerized tomography in the diagnosis of normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Ben-Horin, C.L.; Berezovsky, V.; Kristal, C.A.; Linov, L.; Kahane, E.; Merkin, V.

    2002-01-01

    Normal pressure hydrocephalus (NPH) is a well-defined syndrome consisting of dementia, ataxia and incontinence. The treatment of this condition is installation of ventricle-peritoneal shunt, but only 50% of patients improved after surgery with sustained improvement in 25% of the cases. Another 25% can developed complications after surgery. The main problem is how to select those patients that can enjoy this kind of treatment. CT is a well-known procedure that can show anatomical changes due to NPH. 99mTc DTPA cisternography provides a measure of cerebrospinal flow dynamics and its alteration due to NPH. The aim of the study was to check retrospectively the effectiveness and usefulness of the combination of 99mTc DTPA cisternography and brain CT in the diagnosis of NPH. Methods: 20 charts of patients with clinical suspicion of NPH were checked retrospectively. All of them were clinically examined and passed brain CT and 99mTc DTPA cisternography. Lumbar puncture was done to 5 patients. Mini Mental Test was done only to 5 patients.2 patients had also MRI imaging. Results: 20 charts of patients clinically suspected of NPH were checked. Only 10/20 presented with the clinical triad of dementia, ataxia and incontinence. 12/20 patients were referred to neurosurgical consultation after both imaging studies. 7/12 were diagnosed as NPH and recommended to shunt surgery. 3/7 were operated. 1/3 died after the operation due to complications not related to neurosurgery. 4/7 are waiting for surgery. 2/12 the diagnosis of NPH was cancelled by the neurosurgeons. 1/12 the final diagnosis was obstructive hydrocephalus and another 2/12 the surgeons recommended follow up only. In 4/20 the diagnosis of NPH was role out and in another 4/20 no follow up was available. According to our data, the sensitivity of CT was 100%, specificity 30%, PPV 59% and NPV 100% and for 99mTc DTPA cisternography 100%; 10%; 52,5% and 100% respectively. When combined both examinations the sensitivity and NPV

  1. Technetium-99m as alternative to produce somatostatin-labeled derivatives: comparative biodistribution evaluation with 111In-DTPA-octreotide

    International Nuclear Information System (INIS)

    Melo, Ivani B.; Buchpiguel, Carlos Alberto; Ueda, Laura T.; Araujo, Elaine B. de; Muramoto, Emiko; Barboza, Marycel F. de; Mengatti, Jair; Silva, Constancia P.G. da

    2008-01-01

    Synthetic somatostatin (SST) analogues have been used in the preparation of receptor-specific radiopharmaceuticals for diagnostic and therapy of neuroendocrine (NE) tumors. 111 In-DTPA-Octreotide (OctreoScan®) has found useful for imaging a range of tumors, including NE cancer, carcinoide and lymphoma. Unfortunately, 111 In is a high-cost cyclotron produced radioisotope with gamma emission not so suitable for scintigraphic images and for dosimetry like 99m Tc. This work studied the labeling conditions with 99m Tc and biological distribution in Swiss mice of two SST analogs (HYNIC-Tyr 3 -Octreotide and HYNICTyr 3 - Octreotate) and compared the biodistribution pattern with 111 In-DTPA-Octreotide. 99 mTc-HYNIC-Tyr 3 - Octreotate ( 99m Tc-HYNIC-TATE) and 99m Tc-HYNIC-Tyr 3 -Octreotide ( 99m Tc-HYNIC-OCT) were produced by labeling conditions using tricine and EDDA as coligands. 111 In-DTPA-Octreotide ( 111 In-DTPA-OCT) was produced by labeling DTPA-Octreotide with 111 InCl 3 (Nordion). Radiochemical purity of labeled preparations was determined by ITLC-SG. Biological distribution studies were performed after injection of radiopharmaceuticals on Swiss mice. Labeling procedures resulted on high radiochemical yield for all three preparations and the labeled products presented high in vitro stability. Biological distribution studies evidenced similar general biodistribution of 99m Tc-labeled peptides when compared with indium-labeled peptide with fast blood clearance and elimination by urinary tract. Kidneys uptake of 99 mTc-HYNIC-TATE are similar to 111 In-DTPA-Octreotide, and both are significantly higher than 99 mTc-HYNIC-OCT. All labeled peptides presented similar uptake on liver, but the retention in time at intestines, particularly at large intestine, was more expressive for 111 In-labeled peptide. The %ID of 99m Tc-HYNIC-OCT and 99m Tc-HYNIC-TATE in organs with high density of SST receptors like pancreas and adrenals were significant and similar to obtained for 111

  2. The value of Tc-99m DTPA diuretic renography for assessment of dilated upper urinary tract in children

    International Nuclear Information System (INIS)

    Yang, Ki Ra; Lim, Gye Yeon; Sohn, Hyung Sun; Hahn, Seong Tae; Lee, Jae Mun

    1999-01-01

    The purpose of this study was to evaluate the accuracy of Tc-99m DTPA diuretic renal scans in children with dilated upper urinary tract. We reviewed diuretic renal scans of 14 pediatric patients (age range: 3 days to 4 years) with unilateral hydronephrosis diagnosed by ultrasonography. Diuretic renal scan was done using Tc-99m DTPA and standardized protocol. In 3 neonates, diuretic renal scans were performed within 1 week and 3-7 months after birth. Six patients required pyeloplasty and eight were managed conservatively. All 6 patients requiring pyeloplasty were diagnosed as having ureteropelvic junction obstruction in the diuretic renal scan. In these 6 patients, post-operative renal scans 3-12 months after surgery were converted to nonobstructive pattern in 5 and a nonfunctioning pattern in 1. In 3 patients who underwent diuretic renal scan within 1 week after birth, nonobstructive patterns of initial scan were converted to obstructive patterns in the follow-up scan. However, all patients with nonobstructive diuretic renal scans performed after the neonatal period did well on serial ultrasonography and showed favorable clinical outcome without progression to obstruction. Tc-99m DTPA diuretic renal scan with standardized protocol is useful in assessing suspected ureteropelvic junction obstruction in children as an initial diagnostic or post-operative follow-up modality. Nonobstructive or indeterminate scan results in the neonatal period requires follow-up scan to monitor development of the obstructive pattern

  3. Respiratory clearance of 99mTc-DTPA and pulmonary involvement in sarcoidosis

    International Nuclear Information System (INIS)

    Dusser, D.J.; Collignon, M.A.; Stanislas-Leguern, G.; Barritault, L.G.; Chretien, J.; Huchon, G.J.

    1986-01-01

    To investigate the relationships between the respiratory epithelial clearance of micronic aerosolized /sup 99m/Tc-DTPA (RC-DTPA) and pulmonary function, serum angiotensin-converting enzyme (SACE), and lymphocytic alveolitis in patients with sarcoidosis, RC-DTPA was measured in 49 nonsmokers with pulmonary sarcoidosis and 38 normal nonsmokers. Pulmonary involvement was evaluated on chest roentgenograms (type O = normal, type I = hilar adenopathies, type II = hilar adenopathies associated with parenchymal shadows, type III = parenchymal shadows without adenopathy) and by pulmonary function tests. Serum angiotensin-converting enzyme was determined, and a bronchoalveolar lavage was performed for alveolar lymphocyte differential counting (Ly%). RC-DTPA was increased (greater than or equal to 1.96%/min) in 12 of 31 patients with type II or III involvement but was normal in all 18 patients with type O or I involvement (p = 0.002). Patients with increased RC-DTPA had low FVC, TLC, FEV1, and resting Pao2 (p less than 0.05); resting and exercise AaPo2 were increased (p less than 0.05), but RC-DTPA correlated negatively with FEV1 (p less than 0.01), Pao2 at rest (p less than 0.005), and DLCO (p less than 0.05) and positively with resting and exercise AaPO2 (p less than 0.01). In patients with increased RC-DTPA (42 +/- 17%), Ly% did not differ from Ly% in patients with normal RC-DTPA (34 +/- 16%). SACE was increased in patients with increased RC-DTPA (56 +/- 26 U/ml versus 38 +/- 16 U/ml; p = 0.007) and correlated positively with RC-DTPA (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Glomerular filtration rate in relation to extracellular fluid volume: similarity between 99mTc-DTPA and inulin

    International Nuclear Information System (INIS)

    Gunasekera, R.D.; Allison, D.J.; Peters, A.M.

    1996-01-01

    The aim of the present study was to compare 99m Tc-DTPA plasma clearance kinetics with those of inulin, injected simultaneously, with respect especially to α 2 , rapidity of equilibration within the distribution volume and the components and size of the distribution volume. (orig./MG)

  5. An analysis of 99mTc-DTPA renal dynamic imaging in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Cao Guoxiang; Zhang Yongxue

    2000-01-01

    To investigate the regularity of renal dynamic imaging in the various courses of diabetes mellitus, and then to provide the important evidence variety for diagnosis and treatment. The data of renal dynamic imaging was analyzed on 276 kidneys of 40 normal and 98 diabetic patients, and according to course of disease, the diabetic patients was divided into three groups: ≤1 year, 1-5 year and ≥5 year respectively. Based upon was grouped 99m Tc-DTPA renal dynamic imaging and others, the renal functions into normal, approximately normal, I, II and III injury respectively, and the statistics and analysis of these data were carried out. The extent of renal function injury was related to the course of disease significantly, and it showed that the longer the course, the heavier the damage of renal function, and there was a significant difference between them (P 99m Tc-DTPA renal dynamic imaging can effectively evaluate the extent of renal functions injury and was also valuable for the clinical. Also, the study indicated that in diabetic patients susceptible to urinary tract infection could aggravate the injury of renal function

  6. Exercise increases the lung clearance of inhaled Tc-99m DTPA

    International Nuclear Information System (INIS)

    Meignan, M.; Rosso, J.; Cinotti, L.; Galle, P.

    1985-01-01

    It has been suggested that blood flow have little effect on the lung clearance of Tc-99m DTPA which depends on the alveolar distension. However an increase of pulmonary blood flow, induces a recruitment of new vascular areas which can enhance this clearance. To assess this hypothesis the pulmonary apical and basal clearances of a sumicronic aerosol of Tc-99m DTPA were studied at rest and at exercise in seven non smoking volunteers in upright posture. As a matter of fact exercising upright is known to increase primarily the apical blood flow. After inhalation the subjects were seated on a bicycle their back against a gamma camera which was linked to a computer. The lung radioactivity was registered successively during a resting and an exercising period. At rest there was a gradient of clearance from the apex to the base of the lung, the apical clearance being significantly higher. At exercise (50 Watts, 60 c. min /sup -1/, 7 min.) this regional gradient was enhanced by a large and significant increase of the apical clearances (0.0340 min /sup -1/ +-0.0063 SD versus 0.00183 min /sup -1/ +- 0.074 SD at rest, n = 7, p < 0.01). By contrast the changes of the basal clearances were slight and unsignificant (0.0146 min /sup -1/ +- 0.0062 SD versus 0.0140 min /sup -1/ +- 0.0082 SD). Since exercise induces little distension of the apical alveoli but drastically enhances the apical blood flow, the observed increase of the apical lung clearance could be primarily attributed to the recruitment of new capillaries induced by exercise in the apices. This led to an increase of the surface area permeability product

  7. Computer processed /sup 99m/Tc-DTPA studies of renal allotransplants

    International Nuclear Information System (INIS)

    Pavel, D.G.; Westerman, B.R.; Bergan, J.J.; Kahan, B.D.

    1976-01-01

    In order to refine the diagnostic possibilities of the radionuclide renal study in transplated patients and to compensate for the nonspecificity of the 131 I-hippuran study in some situation, /sup 99m/Tc-DTPA was used simultaneously for imaging and time-activity curves. For these curves to be significant, appropriate background subtraction had to be made with a simple computer-processing method. The results obtained have shown that it is possible to distinguish marked acute tubular necrosis from milder degrees, thus affording a prognostic index in the immediate postoperative period, when the hippuran data are often nonspecific. Further, the diagnosis and follow-up of acute rejection episodes can be improved by the DTPA processed curves. Although these curves when examined individually do not show a specific pattern for rejection, they may reveal striking evolutionary changes when compared to the previous studies, even when the hippuran curves are unchanged. The physiologic basis for the differences between the two time-activity curves may be related to the differential handling of the two radiopharmaceuticals by the kidney

  8. Modification of PLGA nanoparticles for improved properties as a 99mTc-labeled agent in sentinel lymph node detection.

    Science.gov (United States)

    Subramanian, Suresh; Pandey, Usha; Gugulothu, Dalapathi; Patravale, Vandana; Samuel, Grace

    2013-10-01

    We have earlier reported on the possible application of poly [lactide (co-glycolide)] (PLGA) nanoparticles of suitable size to serve as a (99m)Tc-labeled diagnostic tracer in sentinel lymph node detection (SLND). Additional efforts have now been made to improve both the radiolabeling yield and the biological efficacy by modifying the PLGA particles. Two approaches were taken, one based on in situ loading of mebrofenin inside PLGA nanoparticles and the second one based on functionalization of existing terminal carboxylic acid groups on the nanoparticle surface with p-aminobenzyl diethylenetriamine pentaacetic acid (p-NH2-Bz-DTPA) for enhanced availability of functional groups suitable for (99m)Tc complexation. The modified PLGA derivatives were purified and characterized. Radiolabeling of the modified PLGA nanoparticles was carried out with (99m)Tc using stannous chloride as the reducing agent. Mebrofenin encapsulated PLGA nanoparticles (mebrofenin-PLGA) did not show any significant improvement in the radiolabeling yield in comparison to the earlier reported "plain" PLGA nanoparticles, probably due to inaccessibility of the mebrofenin moiety to (99m)Tc upon encapsulation. DTPA-conjugated PLGA nanoparticles (DTPA-PLGA) showed appreciable improvement in radiolabeling yield under more moderate reaction conditions and better stability. In the biological evaluation performed in Wistar rat model, (99m)Tc-DTPA-PLGA nanoparticles showed a considerable increase in uptake in the sentinel node and the percentage popliteal extraction of the preparation was also higher. (99m)Tc-mebrofenin-PLGA did not show any improvement in SLN uptake over plain PLGA nanoparticles. The above results suggest that surface modification of PLGA by covalently coupling DTPA to PLGA nanoparticles prior to (99m)Tc labeling appears to be a superior approach to achieve a suitable (99m)Tc-labeled PLGA nanoparticle preparation for SLND.

  9. Technetium-99m DTPA aerosol and gallium scanning in acquired immune deficiency syndrome

    International Nuclear Information System (INIS)

    Picard, C.; Meignan, M.; Rosso, J.; Cinotti, L.; Mayaud, C.; Revuz, J.

    1987-01-01

    In 11 non-smoking AIDS patients suspected of pneumocystis carinii pneumonia (PCP), the results of Tc-99m DTPA aerosol clearances, gallium scans, and arterial blood gases were compared with those of bronchoalveolar lavage (BAL). Nine patients had PCP. All had increased clearances five times higher than the normal (5.6 +/- 2.3% X min-1 vs 1.1 +/- 0.34% X min-1, N = 10, P less than 0.001), suggesting an increased alveolar permeability. Gallium scans were abnormal in six patients but normal or slightly abnormal in the three others. Four of these nine patients had normal chest x-rays. In two of these the gallium scan was abnormal, but in the two others, only the increased Tc-99m DTPA clearances showed evidence of lung disease. Two patients had normal BAL, with normal clearances and gallium scans. Four out of the nine patients with PCP were studied after treatment. Three recovered and had normal clearance and gallium scans. One still had PCP with increased clearance but normal gallium scan. Gallium scanning and Tc-99m DTPA clearance are useful for detecting lung disease in AIDS patients with suspected PCP and for prompting BAL when chest x-rays and PaO 2 levels are normal. Due to its high sensitivity, a normal Tc-99m DTPA clearance could avoid BAL

  10. Tc-99m DTPA renal function tests and diuretic renogram in the dilated upper urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Sakagami, Yoshinari; Yamaguchi, Osamu; Suzuki, Takayuki; Kameoka, Hiroshi; Shiraiwa, Yasuo; Suzuki, Akira (Fukushima Medical Coll. (Japan))

    1992-09-01

    The authors studied patients with dilated upper urinary tracts (16 patients) using radioisotopic split renal function tests and diuretic renogram with [sup 99]mTc-diethylenetriaminepentaacetic acid (Tc-99m DTPA). The etiology was ureteropelvic function stenosis, 11; primary megaureter, 3; ureteral stenosis, 1; and aberrant vessel, 1. Response to diuresis was classified into 3 groups: i.e., obstructive pattern, non-obstructive pattern and partial obstructive pattern. In the non-obstructive group, split renal function was good, and thus an operation was not indicated. In the obstructive group, split renal function was significantly decreased and these patients underwent surgery. In the partial obstructive group, if function of the obstructed kidney was approximately the same as that of the non-obstructed side, then surgery was considered unnecessary. (author).

  11. Tc-99m DTPA renal function tests and diuretic renogram in the dilated upper urinary tract

    International Nuclear Information System (INIS)

    Sakagami, Yoshinari; Yamaguchi, Osamu; Suzuki, Takayuki; Kameoka, Hiroshi; Shiraiwa, Yasuo; Suzuki, Akira

    1992-01-01

    The authors studied patients with dilated upper urinary tracts (16 patients) using radioisotopic split renal function tests and diuretic renogram with 99 mTc-diethylenetriaminepentaacetic acid (Tc-99m DTPA). The etiology was ureteropelvic function stenosis, 11; primary megaureter, 3; ureteral stenosis, 1; and aberrant vessel, 1. Response to diuresis was classified into 3 groups: i.e., obstructive pattern, non-obstructive pattern and partial obstructive pattern. In the non-obstructive group, split renal function was good, and thus an operation was not indicated. In the obstructive group, split renal function was significantly decreased and these patients underwent surgery. In the partial obstructive group, if function of the obstructed kidney was approximately the same as that of the non-obstructed side, then surgery was considered unnecessary. (author)

  12. Usefulness of 99mTc-DTPA renography and diuretic renography in predicting successful stone discharge following outpatient ESWL in patients with a single ureteral stone

    International Nuclear Information System (INIS)

    Soga, Norihito; Komeda, Yoshinori; Suzuki, Ryuichi; Kawamura, Juichi.

    1996-01-01

    We analyzed the 99m Tc-DTPA renogram with and without diuresis to predict the possibility of stone discharge on the outpatient basis by renogram patterns. Between October 1993 and December 1995, 99m Tc-DTPA renography was performed in 79 patients with a single ureteral stone. The 99m Tc-DTPA renogram pattern was classified into the three types of normal function, obstruction and lower function patterns and the complete stone discharge rate was 93, 63 and 25%, respectively. In addition, diuretic renography using Furosemide was performed in patients with an obstruction pattern and the three renogram patterns of return to the normal curve, a diuretic response and no response were obtained; the complete stone discharge rate was 44, 65.3 and 93%, respectively. From this study, patients with a single ureteral stone with a normal pattern on the regular DTPA renogram and patients with no response pattern on the diuretic renogram, even if in such patients an obstructive pattern was seen on the regular DTPA renogram, seem to be a good candidate for obtaining a high rate of a stone discharge with extracorporeal shock wave lithotripsy (ESWL) treatment in the outpatients basis. (author)

  13. Influence of chest background on pulmonary 99m Tc-DTPA clearance in interstitial lung disease

    International Nuclear Information System (INIS)

    Ishizaka, Akitoshi; Kanazawa, Minoru; Suzuki, Yukio; Hasegawa, Naoki; Kubo, Atsushi; Kawashiro, Takeo

    1992-01-01

    The authors examined the effect of chest extracellular 99m T c -diethylenetriamine pentaacetate (DTPA) as a background in the measurement of pulmonary 99m T c -DTPA clearance in patients with interstitial lung disease (ILD). Eight healthy nonsmokers (HN) and eight patients with ILD were studied. They monitored changes in gamma counts after the inhalation of 99m T c -DTPA aerosol by using a gamma camera placed over the anterior chest. The rate constant of pulmonary 99m T c -DTPA clearance (k; %/min) was assessed by calculating the slope of the decrease in the gamma counts. The chest background, estimated by 99m T c -DTPA intravenous injection, was subtracted from the original data to obtain the corrected DTPA clearance (k c ; %/min). In patients with ILD, k was significantly greater [2.19 ± 1.03 (SD) %/min; n = 8] compared with HN (0.86 ± 0.17%/min; n = 8; P c was also greater (2.80 ± 1.15%/min; n = 8; P c among all subjects (r = 0.987, P 99m T c -DTPA clearance. 16 refs., 2 figs., 2 tabs

  14. 99mTc labeled VIP analog: evaluation for imaging colorectal cancer

    International Nuclear Information System (INIS)

    Rao, P.S.; Thakur, M.L.; Pallela, V.; Patti, R.; Reddy, K.; Li, H.; Sharma, S.; Pham, H.L.; Diggles, L.; Minami, C.; Marcus, C.S.

    2001-01-01

    Early and reliable diagnosis of colorectal cancer continues to be demanding and challenging. Colorectal cancer cells express Vasoactive Intestinal Peptide (VIP) receptors in high density. We have prepared a VIP analog (TP3654), labeled it with 99m Tc, and evaluated it in experimental animals as an agent for imaging colorectal cancer. The tissue distribution of 99m Tc-TP3654 has been compared with that of 111 In-DTPA-Octreotide and 99m Tc-anti-CEA scan in nude mice bearing human colorectal cancer LS174T. Finally, pharmacokinetic and tissue distribution studies of 99m Tc-TP3654 have been performed in four normal human volunteers. Data suggest that 99m Tc-TP3654 can be prepared efficiently without loss of its receptor specificity and biological activity. Although the 24 hr tumor uptake of 99m Tc-TP3654 in the animal model used was modest (0.21 ± 0.07% I.D./g), the tissue distribution profile was more favorable than that of 111 In-DTPA-Octreotide or 99m Tc-anti-CEA scan. Human studies indicated that 99m Tc-TP3654 had no adverse effect in any subject. Within 24 hours, approximately 70% of the injected dose cleared through the kidneys, and approximately 20% through the hepatobiliary system. In these non-fasting volunteers hepatobiliary clearance was slow and in cancer patients tumor uptake was rapid. Data suggest that 99m Tc-TP3654 is a promising agent for imaging colorectal cancer

  15. Capillary permeability of 99mTc-DTPA in canine myocardium determined by intracoronary bolus injection and residue detection

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Efsen, F; Haunsø, S

    1989-01-01

    chest dogs (group A) these indicators were administered separately as bolus injections into a cannulated diagonal branch of the left anterior descending coronary artery (LAD) and the curve of the response function was recorded by external activity registration. In further experiments on closed and open...... chest dogs (group B) 99mTc-DTPA was injected via a coronary angiography catheter into the ostium of the left coronary artery and the response curve was obtained by external registration. Regional myocardial perfusion coefficients were determined by the local 133xenon washout technique and from kinetic...... by local 133Xe washout technique. Mean values of the extraction fractions (E) were 0.463 and 0.475 for 99mTc-DTPA and 51Cr-EDTA, and the permeability-surface area products (PdS) were 52.8 and 57.5 ml.min-1.100 g-1 respectively. At the conventional capillary surface area estimate of 500 cm2.g-1...

  16. Exercise induced renal dysfunction demonstrated both in hypertensives and normotensive controls studies by Tc-99m-DTPA

    International Nuclear Information System (INIS)

    Mizuiri, S.; Hayashi, I.; Ohara, T.; Hirata, K.; Sasaki, Y.

    1985-01-01

    It was previously reported that the hippurate transport disturbance after exercise is a specific phenomenon to patients with hypertension. The authors' study with Tc-99m-DTPA revealed exercise induced renal dysfunction not only in hypertensives (H) but also in normotensive controls (N). The details of the investigation is presented. Tc-99m-DTPA was intravenously injected at rest and during bicycle ergometric stress to 14 H and 14 N in sitting position. Serial dynamic renal images were taken, of which data were simultaneously stored in a data processor for later analysis. The renogram was drawn setting ROI on each kidney. Peak counts (PC) of vascular phase, peak time (PT) of secretory phase and radioisotope retention rate (RR) at 10 minutes were the parameters being compared between at rest and at exercise. GFR of each kidney was determined. Blood samples were obtained at rest and at the end of exercise for the measurement of aldosterone (ALD), plasma renin activity (PRA) and catecholamines (A, NA). Exercise caused significant lowering of PC, prolongation of PT and increase in RR (10 min. counts/peak counts) both in H and N. GFR (miota/min.) during exercise was significantly lower than at rest in both H (80 +- 22 vs 93.8 +- 16.9, p<0.02) and N (84 +- 17 vs 102 +- 15, p<0.01). ALD, PRA, A and NA are all elevated during exercise both in H and N. None of the rest-exercise differences significantly differed between H and N. The data indicate the exercise induced renal dysfunction demonstrated by Tc-99m-DTPA renograms is not specified to H but can also be observed in N, which may be resulted from the common changes in H and N of GFR and humoral factors

  17. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  18. Gfr estimation using 99mTc DTPA gates method for assessment of early diabetic nephropathy - a comparison with 24-hour creatinine clearance

    International Nuclear Information System (INIS)

    Ghafoor, S.; Ali, M.K.; Khan, G.

    2014-01-01

    To correlate Gates glomerular filtration rate (GGFR) using technetium-99m diethylene triaminepentacetic acid (99mTc DTPA) with 24-hour creatinine clearance (CRCL) and to establish relationship with duration of diabetes in patients with early diabetic nephropathy. Study Design: A cross-sectional comparative study carried out in Nuclear Medical Centre from Aug 2009 to Jan 2010 at Armed Forces Institute of Pathology (AFIP), Rawalpindi, Pakistan. Patients and Methods: A total of eighty three subjects were enrolled, who were divided into three groups; group 1 comprised 31 normotensive diabetics, group 2 had 37 hypertensive diabetics while group 3 had 15 normal subjects. The DTPA GFR and creatinine clearance in healthy subjects as well as diabetic patients were compared using the unpaired student's t-test. The linear association between GFR, creatinine clearance and disease duration was expressed by Pearson's correlation coefficient 'r' along with their significance levels. Results: Gates GFR showed hyperfiltration in normotensive diabetics (96.6 +- 3.3 ml/min/1.73 m/sub 2/), significantly (p<0.05) higher than controls (85.5 +- 5 ml/min/1.73 m/sub 2/), whereas hypertensive diabetics had a significantly lower (p<0.05) Gates GFR (76.8 +- 3.7) than that of controls. Significant degree of correlation existed between GGFR and CRCL in hypertensive diabetics (p<0.05, r=0.716) and controls (r=0.546). Gates GFR also showed good correlation with duration of diabetes in both diabetic groups as compared to that of CRCL. GGFR also correlated well with duration of hypertension 0.37 (0.31-0.43) as compared to CRCL 0.155 (0.15-0.16) in all groups. Conclusions: The 99mTc-DTPA clearance correlates significantly with 24-hour creatinine clearance as well as with disease duration and can provide a simple and convenient index of kidney function in patients of early diabetic nephropathy. (author)

  19. Evaluation of 99m Tc- DTPA renal scanning for localization and shielding of the kidneys in patients candidate for abdominal radiotherapy

    International Nuclear Information System (INIS)

    Alavi, M.; Omidvari, Sh.

    2005-01-01

    Clinical radiation nephropathy can result in considerable morbidity and/or mortality. Renal tolerance (TD5/5) has been stated to be 20 Gy when irradiation has been delivered to both kidneys in 3-5 weeks. Therefore to minimize renal toxicity in these patients, localization and shielding of the kidneys are essential. This study was carried out to evaluate the role of 99m Tc-DTPA renal scintigraphy in renal localization for perfect shielding. Methods: from April 2000 to March 2001, thirteen patients had complete history, physical examination, serum creatinine level, complete blood count, urinalysis and abdominal sonography. Then the patients were referred to nuclear medicine department. After I. V. injection of 10 mCi 99m Tc-DTPA , the kidneys were localized by gamma camera and marked on skin. All patients received abdominal radiation with A-P and P-A fields with cobalt 60 machine up to 3000-5000CGY. Kidneys were shielded posteriorly after 15OOcGY with 5 half value layer blocks. Results: after minimum follow-up of 24 months, no evidence of increasing blood pressure, edema, proteinuria, rising in serum creatinine or changing in kidney size was found. Conclusion: the results show that localization of kidneys by 99m Tc-DTPA is a useful, easy and safe method to shield kidneys in these patients

  20. 99mTc-DTPA renal scanning as a confirmatory study in the diagnosis of neonatal adrenal hemorrhage

    International Nuclear Information System (INIS)

    Habif, D.V. Jr.; Berdon, W.E.; Baker, D.H.; Pritzker, H.; Fawwaz, R.; Johnson, P.

    1979-01-01

    99mTc-DTPA renal scanning offers a method for demonstrating adrenal hemorrhage as a cause of flank mass in the neonate and for assessing renal function. The hemorrhagic adrenal appears as a tracer-free area over the flattened and displaced kidney. The method is low in radiation and is not hampered by obscuring bowel contents

  1. Binding and clearance of Tc-99m pyrophosphate from the lungs of smokers and nonsmokers

    International Nuclear Information System (INIS)

    Isitman, A.T.; Effros, R.; Collier, B.D.; Palmer, D.W.; Krasnow, A.Z.; Hellman, R.S.; Hacker, A.; Berger, C.; Trembath, L.

    1990-01-01

    Both acute and chronic lung disorders that affect the alveolar epithelium increase the rate at which aerosolized Tc-99 m DTPA is cleared from the lungs. Transalveolar clearance of Tc-99 DTPA has been used to detect lung injury, but- because smokers have a much faster clearance rate of Tc-99m DTPA-this examination has been limited primarily to nonsmokers. The purpose of this paper is to determine if the clearance of a larger molecule, Tc-99m PYP (molecular weight by ultrafiltration between 1.000 and 3,000 daltons), is also accelerated by smoking. Clearances of each indicator were studies for 6 hours in eight normal nonsmoking subjects and seven (otherwise normal smokers)

  2. Measurement of GFR by Tc-99m DTPA: Comparison of 5 plasma sample and 2 plasma sample methods in North Indian population

    International Nuclear Information System (INIS)

    Mittal, B.R.; Bhattacharya, A.; Singh, B.; Jha, V.; Sarika, Kumar R.

    2007-01-01

    Assessment of Glomerular filtration rate (GFR) has significant impact on both prognosis and treatment of patients with renal disease. In this study we compared the two-plasma-sample method (G2S) using a MS excel spreadsheet based program, with a manual five-plasmasample method (GS) used to measure GFR by determining Tc-99m-diethylenetriamine penta-acetic acid (Tc-99m DTPA) clearance in patients with chronic kidney disease (CKD) and healthy renal donors. The study was conducted in 148 subjects (64 men and 84 women; age range 14 to 70 yr); 59 patients of CKD and 89 prospective healthy kidney donors. Tc-99m DTPA (74-100 MBq) was injected intravenously and thereafter blood samples were obtained at 60, 90, 120, 150 and 180 min via the patent venflon. Radioactivity in the injection syringe and plasma was measured by means of a multi-well gamma counter. The correlation coefficient between the 2 methods was 0.9453, with a slope of 0.90 and an intercept of 14.72 mL/min. Bland Altman plot of disagreement showed that G2S underestimated the GFR values by 9.0 ml/min, 11.3 ml/min and 6.9 ml/min, in the entire study, CKD and healthy donor groups respectively. Our results indicate that in spite of good correlation between GS and G2S method, the G2S method constantly underestimated GFR in our study population. However, regression equation may be applied to the GFR values estimated by G2S method to match the GFR determined by GS method. (author)

  3. Measurement of gastric emptying time in various positions using sup(99m)Tc-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Shibatsuji, H; Hamada, S; Takahashi, H; Ohishi, H; Hachiya, T [Nara Medical Univ., Kashihara (Japan)

    1976-04-01

    Gastric emptying with the patients in various positions was evaluated in a group of 8 volunteers by means of serial recordings of gastric radioactivity after administration of a test meal labelled with sup(99m)Tc-DTPA. Gastric emptying time was measured in the supine, prone and sitting position, and the time, which differed according to the position, was expressed as a half life (T1/2) of meal in the stomach. Emptying time was shorter in the prone position and longer in the supine position.

  4. Usefulness of {sup 99m}Tc-DTPA renography and diuretic renography in predicting successful stone discharge following outpatient ESWL in patients with a single ureteral stone

    Energy Technology Data Exchange (ETDEWEB)

    Soga, Norihito; Komeda, Yoshinori [Yokkaichi Health Insurance Hospital, Mie (Japan); Suzuki, Ryuichi; Kawamura, Juichi

    1996-11-01

    We analyzed the {sup 99m}Tc-DTPA renogram with and without diuresis to predict the possibility of stone discharge on the outpatient basis by renogram patterns. Between October 1993 and December 1995, {sup 99m}Tc-DTPA renography was performed in 79 patients with a single ureteral stone. The {sup 99m}Tc-DTPA renogram pattern was classified into the three types of normal function, obstruction and lower function patterns and the complete stone discharge rate was 93, 63 and 25%, respectively. In addition, diuretic renography using Furosemide was performed in patients with an obstruction pattern and the three renogram patterns of return to the normal curve, a diuretic response and no response were obtained; the complete stone discharge rate was 44, 65.3 and 93%, respectively. From this study, patients with a single ureteral stone with a normal pattern on the regular DTPA renogram and patients with no response pattern on the diuretic renogram, even if in such patients an obstructive pattern was seen on the regular DTPA renogram, seem to be a good candidate for obtaining a high rate of a stone discharge with extracorporeal shock wave lithotripsy (ESWL) treatment in the outpatients basis. (author)

  5. Study with radio aerosol of DTPA technetium-99 m in individuals with pulmonary disease by amiodarone

    International Nuclear Information System (INIS)

    Terra Filho, M.

    1989-01-01

    In order to evaluate the role of the clearance of 99 m Technetium chelated to diethylenetriamine-penta-acetate (99 m Tc-DTPA) in amiodarone induced pulmonary disease, 40 individuals were studied in four groups. After spirometry, where a volume-time curve was registered, all individuals inhaled 740 MBq of 99 m Tc-DTPA diluted in 4 ml of saline, for five minutes. Pulmonary images were obtained in a computerized scintillation camera and 9 regions of interest were selected. (author)

  6. Detection of alveolar epithelial injury by 99mTc-DTPA radioaerosol inhalation lung scan following blunt chest trauma

    International Nuclear Information System (INIS)

    Okudan, B.; Han, S.; Baldemir, M.; Yildiz, M.

    2004-01-01

    DTPA clearance rate is a reliable index of alveolar epithelial permeability, and is a highly sensitive marker of pulmonary epithelial damage, even of mild degree. In this study, 99m Tc-DTPA aerosol inhalation scintigraphy was used to assess the pulmonary epithelial membrane permeability and to investigate the possible application of this permeability value as an indicator of early alveolar or interstitial changes in patients with blunt chest trauma. A total of 26 patients was chest trauma (4 female, 22 male, 31-80 yrs, mean age; 53±13 yrs) who were referred to the emergency department in our hospital participated in this study. Technetium-99m diethylene triamine pentaacetic acid (DTPA) aerosol inhalation scintigraphy was performed on the first and thirtieth days after trauma. Clearance half times (T 1/2 ) were calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was calculated on the first-minute image. On the first day, mean T 1/2 value of the whole lung was 63±19 minutes (min), and thirtieth day mean T 1/2 value was 67±21 min. On the first day, mean PI values of the lung and 30th day mean PI value were 0.60±0.05, and 0.63 ±0.05, respectively. Significant changes were observed in radioaerosol clearance and penetration indices. Following chest trauma, clearance of 99m Tc-DTPA increased owing to breakdown of the alveolar-capillary barrier. This increase in the epithelial permeability of the lung appears to be an early manifestation of lung disease that may lead to efficient therapy in the early phase. (author)

  7. Monoexponential analysis of plasma disappearance of 99mTc-DTPA and 131I-iodohippurate: A reliable method for measuring changes of renal function

    International Nuclear Information System (INIS)

    Clifton, G.G.; Anderson, C.; McMahon, G.; Vargas, R.; Wallin, J.D.

    1989-01-01

    Glomerular filtration rate and effective renal plasma flow were measured in 170 subjects using monoexponential analysis of plasma disappearance curves for 99m Tc-DTPA and 131 I-iodohippurate after single injection. In the current study population, glomerular filtration rate and effective renal plasma flow decreased with increasing age, were less in females than in males, and were less in hypertensives than in normotensives. Differences in glomerular filtration rate according to age and sex in the current study were similar to those reported using traditional creatinine clearance methodology. Monoexponential treatment of plasma isotope disappearance gave reproducible values for both glomerular filtration rate and effective renal plasma flow when measured either during the day or on a daily basis. Intraindividual coefficient of variation was less than 10% for both 99m Tc-DTPA and 131 I-iodohippurate clearances derived from monoexponential analysis. These results demonstrate that monoexponential analysis of plasma disappearance curves for 99m Tc-DTPA and 131 I-iodohippurate after a single injection is a useful method for evaluating changes in renal hemodynamics either during chronic drug therapy or acutely after single dose administration

  8. Clearance of technetium-99m-labeled DTPA in hyperthyroidism without clinical evidence of lung disease, and relation to pulmonary function

    International Nuclear Information System (INIS)

    Guldiken, S.; Tugrul, A.; Altiay, G.; Hacimahmutoglu, S.; Durmus-Altun, G.

    2005-01-01

    The mechanisms of dyspnea and exercise intolerance have not been fully elucidated. We aimed to investigate the clearance rate of technetium-99m diethyltriaminepentaaceticacid (Tc-99m DTPA) from lungs in hyperthyroid patients without clinical evidence of lung disease and to explore the interactions between their Tc-99m DTPA radioaerosol lung scintigraphy, spirometric measurements, and the levels of thyroid hormones. We studied 19 hyperthyroid patients and 16 sex- and age-matched controls. Thyroid hormone levels were assessed. Spirometric lung function tests, diffusing capacity of the lung for carbon monoxide (DLCO) and the clearance rate of Tc-99m DTPA were performed in all participants. Ratio of DLCO value to the alveolar ventilation (DLCO/VA) and the means of half-time (T 1/2 ) of Tc-99m DTPA clearance rate, which were used to evaluate alveolar-capillary membrane permeability, were calculated. There were no statistical differences between spirometric parameters (vital capacity (VC), force vital capacity (FVC), one second forced expiratory volume (FEV 1 )/FVC, mean forced expiratory flow during the middle of FVC (FEF 25-75)) of the two groups (p>0.05). Although the mean FEV 1 level was significantly lower in the hyperthyroid patients than the control subjects (p 1 was only less than 80 percent of the predicted value. No significant difference in the means of DLCO, DLCO/VA or T 1/2 values of Tc-99m DTPA clearance was observed between the two groups (p>0.05). In hyperthyroid patients, there was a positive relation between DLCO/VA, DLCO/VA% and T 1/2 values of Tc-99m DTPA clearance (p 1/2 values of Tc-99m DTPA clearance in hyperthyroid group (p>0.05). We conclude that increased thyroid hormones have no effect on permeability of alveolar-capillary membrane in hyperthyroid patients. (author)

  9. Measurement of vesicoureteral reflux with intravenous 99mTc-DTPA compared to radiographic cystography

    International Nuclear Information System (INIS)

    Hedman, J.K.; Kempi, V.; Voss, H.

    1978-01-01

    The results of a /sup 99m/Tc-DTPA study of vesicoureteral reflux in 51 children with recurrent urinary tract infections were compared with those of radiographic micturition cystourethrography. Reflux, shown by either of the two methods, was regarded as an indication of the disorder. Neither method was regarded as a standard reference method. Agreement between the two methods was obtained in 90 of 102 renal units, i.e., ureter and/or renal pelvis (88 percent). Statistical analysis performed on the remaining 12 cases showed that the two procedures usually gave similar results

  10. Comparison of clinical imaging characteristics of 99mTc-EDDA/HYNIC-TOC with 111In-DTPA-octreotide: first result of a prospective phase II study

    International Nuclear Information System (INIS)

    Gabriel, M.; Decristoforo, C.; Wenger, M.; Guggenberg, E. von; Moncayo, R.; Mather, S.J.

    2002-01-01

    Full text: 99m Tc-EDDA/HYNIC-TOC(Tc-TOC) shows very similar clinical pharmacokinetics compared with 111 In-DTPA-octreotide (In-OCT), the gold standard for somatostatin receptor (SSTR) scintigraphy, and is a promising agent to image SSTR-positive tumors. Here we present the first results of a phase II trial comparing the clinical value of Tc-TOC in a prospective intra-patient comparison with In-OCT. Until now 26 oncological patients were enrolled in the study after giving informed consent. The patients presented with thyroid adeno-carcinomas (n=5), MW (n=3), GEP-tumors (n=10), carcinoid syndromes with unknown primary lesions (n=4), paragangliomas (n=2) and pituitary tumor (n=2), one of whom due to MEN. Posterior and anterior views and SPECT images of the corresponding ROIs were acquired at 4 hrs and 24 hrs alter injection of 111 MBq of In-OCT (octreoscan(r)). TcTOC was given at a dose of 300-350 MBq and imaging was done at 4 hrs p.i. including whole body planar and SPECT studies. Interpretations of these two sets of planar data were done independently by two different viewers. Final confirmation of suspected lesions was obtained by correlative inspection of matched CT or MR scans. In 7 patients SSTR-scintigraphy was negative with both Tc-TOC and In-OCT. Matching positive scintigraphic results with both tracers were obtained in 17 out of 19 patients. In-OCT failed to detect two CT-positive thoracic lesions in two patients with thyroid cancer, whereby these lesions were seen by Tc-TOC. In this series of patients 99m Tc-EDDA-HYNIC-TOC imaging resulted in equivalent diagnostic information on the SSTR-Status, with advantages of a single acquisition, one day protocol and lower radiation dose. The excellent imaging properties resulted in improved diagnosis in 2 of 26 patients when compared to 111 In-DTPA-octreotide. (author)

  11. The use of technetium-99m-DTPA in the diagnosis of tuberculous meningitis

    International Nuclear Information System (INIS)

    Von Wenzel, K.S.

    1988-03-01

    As 82 Br is not available locally in South West Africa on a daily basis a technetium preparation, 99m Tc-DTPA, was used in the diagnosis of patients with tuberculous meningitis. The 99m Tc-DTPA partition test was compared with the 82 Br partition test on 22 trial subjects. The trial subjects varied in age (0,8-57 years), sex and race. There were 7 patients diagnosed by the clinicians as having tuberculous meningitis. All patients were placed on anti-tuberculous meningitis treatment and all, except 2, one of whom regressed and 1 who died 7 days later, improved slowly. The 9 patients with viral meningitis received no antibiotics and recovered rapidly on symptomatic treatment only. With all 5 the septic meningitis cases, the organism was identified and there was thus no diagnostic uncertainty. One normal control subject was also examined. It would appear from the results that both 82 Br, as well as 99m Tc-DTPA, cross the blood-brain barrier to a greater extent in the case of tuberculous meningitis, compared to viral meningitis. Although the accuracy of the 82 Br test, if a critical ratio value of 1,3 was chosen, is 90,6% compared to 86,9% of the 99m Tc-DTPA partition test if a critical ratio value of 3 was chosen, there are still advantages to the use of the technetium preparation. These include the availability, cost and lower radiation dose per MBq as well as the possibility of brain imaging. 10 figs., 58 refs., 9 tabs

  12. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours; first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives.

    Science.gov (United States)

    Decristoforo, C; Mather, S J; Cholewinski, W; Donnemiller, E; Riccabona, G; Moncayo, R

    2000-09-01

    [111In-diethylene triamine penta-acetic acid-D-Phe1]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99mTc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99mTc-EDDA/HYNIC-TOC were compared with those of 111In-DTPA-octreotide in six cases, and with those of 111In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111In-DTPA-octreotide but faster than that of 111In-DOTA-TOC, while urinary excretion was lower compared with the 111In derivatives. Semi-quantitative region of interest analysis showed that 99mTc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99mTc images. We conclude that 99mTcEDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111In-labelled octreotide derivatives.

  13. 99mTc-EDDA/HYNIC-TOC: a new 99mTc-labelled radiopharmaceutical for imaging somatostatin receptor-positive tumours: first clinical results and intra-patient comparison with 111In-labelled octreotide derivatives

    International Nuclear Information System (INIS)

    Decristoforo, C.; Cholewinski, W.; Donnemiller, E.; Riccabona, G.; Moncayo, R.

    2000-01-01

    [ 111 In-diethylene triamine penta-acetic acid-d-Phe 1 ]-octreotide (DTPA-octreotide) scintigraphy has gained widespread acceptance as a diagnostic clinical procedure in oncology for imaging somatostatin receptor-positive tumours. However, indium-111 as a radiolabel has several drawbacks, including limited availability, suboptimal gamma energy and high radiation burden to the patient. We have recently reported on the preclinical development of 99m Tc-EDDA/HYNIC-TOC, a new octreotide derivative which showed promising results both in vitro and in vivo. We now report our initial clinical experiences with this new radiopharmaceutical in ten oncological patients. The clinical diagnoses were: carcinoid syndrome (n=5), thyroid cancer (n=3), pancreatic cancer (n=1) and pituitary tumour (n=1). The biodistribution and kinetics of 99m Tc-EDDA/HYNIC-TOC were compared with those of 111 In-DTPA-octreotide in six cases, and with those of 111 In-DOTA-TOC in five cases. With the new tracer tumours were imaged within 15 min after injection and showed the highest target/non-target ratios 4 h after injection. Tumour uptake persisted up to 20 h p.i. The rate of blood clearance was similar to that of 111 In-DTPA-octreotide but faster than that of 111 In-DOTA-TOC, while urinary excretion was lower compared with the 111 In derivatives. Semi-quantitative region of interest analysis showed that 99m Tc-EDDA/HYNIC-TOC produced higher tumour/organ (target/non-target) ratios than the 111 In derivatives, especially in relation to heart and muscle. Significantly more lesions could be detected in 99m Tc images. We conclude that 99m Tc-EDDA/HYNIC-TOC shows better imaging properties for the identification of somatostatin receptor-positive tumour sites than currently available 111 In-labelled octreotide derivatives. (orig.)

  14. Assessment of peritoneal membrane permeability by Tc-99m-excretion in patients undergoing CAPD

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Jeloka, T.K.; Sharma, R.K.

    2002-01-01

    Full text: Among various conservative treatment modalities for end stage renal disease (ESRD), continuous ambulatory peritoneal dialysis (CAPD) is increasingly being used in many centers. The success of CAPD depends largely on the permeable characteristics of the peritoneal membrane. Peritoneal Equilibration Test (PET), first described by Twardowski in 1987, is the most commonly used method for determination of peritoneal membrane characteristics. However, this test has several limitations. In order to find an alternative method for assessing peritoneal membrane characteristics we undertook this prospective study involving 20 patients. The main objective was to determine whether peritoneal excretion of intravenously applied Tc-99m-DTPA can be used for this purpose. 20 patients undergoing regular CAPD were included in this study. 370 MBq (10 mCi) of Tc-99m-DTPA was injected intravenously in the same standard preconditions as for the PET evaluation. A standard dose of 370 MBq (10 mCi) DTPA was kept and used later for calculations. At the end of 4 hours, a dialysate fluid sample was collected and the total dialysis effluent volume was measured. Excretion of Tc-99m-DTPA into the dialysate fluid as percentage of injected dose was calculated. Simultaneously standard PET values were determined. The peritoneal excretion of Tc-99m-DTPA ranged from 8 to 16 % of the injected dose depending upon the peritoneal membrane permeability. The patients were divided into following four groups depending upon DTPA excretion. High transporters (15 % and above); high average(12-15 %); low average (10-12 %); low transporters (10 % and less). When the results were compared with standard PET values, a good correlation could be established. We conclude that the radioisotope method using Tc-99m-DTPA can a good alternative technique to assess peritoneal membrane permeability. (author)

  15. Permeability of ferret trachea in vitro to 99m Tc-DTPA and [14C]antipyrine

    International Nuclear Information System (INIS)

    Hanafi, Z.; Webber, S.E.; Widdicombe, J.G.

    1994-01-01

    Platelet-activating factor (PAF) and vasoactive drugs were tested on permeability of ferret trachea in vitro by measuring fluxes of 99m T c -diethylenetriamine pentaacetic acid ( 99m T c -DTPA; hydrophilic) and [ 14 C]antipyrine ([ 14 C]AP; lipophilic) across the tracheal wall. Tracheae were bathed on both sides with Krebs-Henseleit buffer, with luminal buffer containing either 99m T c -DTPA or [ 14 C]AP. Luminal and abluminal radioactivities, potential difference, and tracheal smooth muscle tone were measured. Baseline 99m T c -DTPA and [ 14 C]AP permeability coefficients were - 4.7 ± 0.6 (SE) x 10 -7 and -2.2 ± 0.1 x 10 -5 cm/s, respectively. PAF (10 μM) increased permeability to 99m T c -DTPA to -35.3 ± 7.6 x 10 -7 cm/s (P 14 C]AP did not change, suggesting that paracellular but not transcellular transport was affected. Abluminal and luminal applications of methacholine (MCh, 20 μM), phenylephrine (PE, 100 μM), and albuterol (Alb, 100 μM) caused no change in permeability to 99m T c -DTPA before or after exposure to luminal PAF, but abluminal histamine (Hist, 10 μM) significantly increased permeability. Abluminal Hist decreased permeability to [ 14 C]AP before and after exposure to PAF. MCh, PE, and Hist increased smooth muscle tone; Alb and PAF had no effect. Thus, only PAF and Hist altered permeability to 99m T c -DTPA, and MCh, PE, and Hist changed smooth muscle tone. Tracheal permeability changes were greater for the hydrophilic than for the lipophilic agent. 37 refs., 11 figs., 1 tab

  16. Pre-targeted tumor imaging with avidin-McAb and 99Tcm-DTPA-Biotin

    International Nuclear Information System (INIS)

    Zhang Jinming; Tian Jiahe; Wang Yuqi; Liu Xi; Sun Xin

    2002-01-01

    Objective: Biotin-avidin is used as pre-targeting system (BAS) in radioimmunoimaging in order to decrease radiation background and dose associated with the use of directly labelled McAb. The authors tried to use 99 Tc m to substitute 111 In to label DTPA-biotin to evaluate the value of the 99 Tc m -DTPA-biotin in BAS. Methods: DTPA-biotin solution was mixed with SnCl 2 and then fresh eluted 99 Tc m . The solution incubated for 10 min at room temperature. Mice bearing lung tumor (LA-795) with and without metastases in lung underwent 3-step pre-targeting test. Briefly, biotin-C50 was injected first, then avidin and 99 Tc m -DTPA-biotin was respectively given 1 day, 2 days later. Directly labelled C50 with 99 Tc m was used as control agent. Results: The labelling yield of 99 Tc m -DTPA-biotin was over 90%. The amount of SnCl 2 was the key feature in labelling. The tumor could be seen at 2 h after injection of 99 Tc m -DTPA-biotin with γ camera in 3- step groups. The tracer uptake in tumor was (1.35 +- 0.45)% ID/g at 2 h after injection, Tumor/Blood (T/B) was 5.86, T/Muscle (T/M) was 8.43. In control group which received 99 Tc m -DTPA-biotin only, the T/B was 0.85, T/M 1.1. For the directly labelled C50, the T/B was 1.65, T/M was 2.0 at 8 h after injection. Conclusion: Avidin-biotin pre-targeting system can be labelled with 99 Tc m , and the BAS can image the tumor as early as 2 h after injection

  17. Gel chromatographic behavior of Tc-99m-labeled compounds in aqueous solution

    International Nuclear Information System (INIS)

    Suzuki, T.; Wagner, H.N. Jr.; Burns, H.D.; Dannals, F.F.

    1984-01-01

    The purpose of this study was to elucidate the interaction of Tc-99m-labeled compounds (Tc-99m 0/sub 4/-bar, Tc-99m glucoheptonate, Tc-99m DTPA, Tc-99m disofenin) with the chromatographic gels, to determine their relative molecular sizes and molecular structures in aqueous solution, which are based on their biomenbrane transport mechanism and quality control analysis. Each Tc-99m-labeled compound was eluted and analyzed by three different gel chromatrography systems varying buffers: Sephadex G-25, Sephadex LH-20 and Bio-Gel P-4. The best separation between the elution peaks of all compounds except Tc-99m glucoheptonate was achieved on Sephadex G-25 in methanol-0.025OM Tris-HCL buffer (pH 7.6) (1:1) which could avoid the aromatic interaction with the gels. Tc-99m glucoheptonate was well eluted only on a Bio-Gel P-4 column but its elution peak was not separated from other compounds' peaks. The elution of Tc-99m disofenin was delayed on Sephadex G-25 gel and Bio-Gel P-4 columns in 0.9% NaCl and Tris-HCl buffer(ph 7.6) and on Sephadex LH-20 column in methanol-Tris-HCl buffer, because of the aromatic ring interaction with the gels. The relative molecular size index ( Kav ) calculated from the elution volume of the gel chromatography. Kav of Tc-99m 0/sub 4/-bar(MW=163), Tc-99m DTPA (MW=492?) and TC-99m disofenin (MW=707) on Sephadex G-25 in methanol-0.025OM Tris-HCl buffer(pH 7.6) (1:1), which was the most suitable combination of the gel and the buffer, were 0.976, 0.477 and 0.200, respectively. They inversely correlated with their estimated molecular weight. The interaction of Tc-99m-labeled compounds with the chromatographic gels should be considered in quality control procedure for Tc-99m radiopharamaceuticals

  18. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  19. Transport of /sup 99m/Tc complexes through the blood-brain barrier

    International Nuclear Information System (INIS)

    Loberg, M.D.; Corder, E.H.; Fields, A.T.; Callery, P.S.

    1979-01-01

    Thirteen /sup 99m/Tc complexes have been synthesized and used to determine the relationships between protein binding, lipophilicity and membrane transport. The lipophilicity of the /sup 99m/Tc complexes was altered by adding substituents to either IDA, EDTA, DTPA or oxine; membrane transport was estimated using the brain uptake index (BUI) method. The BUI of the /sup 99m/Tc complexes was found to vary directly with lipophilicity and inversely with protein binding. These results demonstrated that /sup 99m/Tc-oxine derivatives are better suited for use in the development of intracellular tracers than are the /sup 99m/Tc derivatives of aminopolycarboxylates

  20. A simple and sensitive separation technique of 99Mo and 99mTc from their equilibrium mixture

    International Nuclear Information System (INIS)

    Swadesh Mandal; Ajoy Mandal

    2014-01-01

    The present work describes a simple and inexpensive separation method of 99 Mo from the equilibrium mixture. The liquid-liquid extraction technique has been employed to separate 99 Mo and 99m Tc using triisooctylamine (TIOA). The 99 Mo and 99m Tc were quantitatively separated out in 2 M TIOA with tripled distilled water; 99m Tc was back extracted from TIOA organic phase to aqueous phase by 0.1 M DTPA. The species information or indirect speciation of molybdenum was also established by the extraction profile of the molybdenum. (author)

  1. Converting to increased Tc-99m DTPA renal flow from slight decrease in renal flow following angioplastic procedures in a patient with unequal renal artery stenoses

    International Nuclear Information System (INIS)

    Shih Weijen; Mitchell, B.L.

    1990-01-01

    The use of Tc-99m DTPA renal flow imaging has increased in importance since the introduction of catheter angioplasty. The high diagnostic accuracy and non-invasive technique as compared to digital subtraction angiography have done much to enhance its usage in the evaluation of renal functional status. This paper reports Tc-99m DTPA renal flow imaging findings before and after angioplasty in a patient with bilateral renal artery stenosis. The slight decrease in Tc-99m DTPA renal flow on the kidney before angioplasty converted to an increase in flow on the right kidney after angioplasty. Post procedural blood flow was much higher on the right, where stenosis was previously more severe. It is hypothesized that the right kidney was protected from elevated aterial pressure by its 90% arterial stenosis while the left kidney was exposed to elevated systemic blood pressure. Because of vascular damage to the unprotected left kidney, post-angioplasty blood flow was less in the left kidney than in the ischemic but protected right kidney. (orig.) [de

  2. Utility of radioisotopic filtration markers in chronic renal insufficiency: Simultaneous comparison of 125I-iothalamate, 169Yb-DTPA, 99mTc-DTPA, and inulin. The Modification of Diet in Renal Disease Study

    International Nuclear Information System (INIS)

    Perrone, R.D.; Steinman, T.I.; Beck, G.J.; Skibinski, C.I.; Royal, H.D.; Lawlor, M.; Hunsicker, L.G.

    1990-01-01

    Assessment of glomerular filtration rate (GFR) with inulin is cumbersome and time-consuming. Radioisotopic filtration markers have been studied as filtration markers because they can be used without continuous intravenous (IV) infusion and because analysis is relatively simple. Although the clearances of 99mTc-DTPA, 169Yb-DTPA, and 125I-iothalamate have each been compared with inulin, rarely has the comparability of radioisotopic filtration markers been directly evaluated in the same subject. To this purpose, we determined the renal clearance of inulin administered by continuous infusion and the above radioisotopic filtration markers administered as bolus injections, simultaneously in four subjects with normal renal function and 16 subjects with renal insufficiency. Subjects were studied twice in order to assess within-study and between-study variability. Unlabeled iothalamate was infused during the second half of each study to assess its effect on clearances. We found that renal clearance of 125I-iothalamate and 169Yb-DTPA significantly exceeded clearance of inulin in patients with renal insufficiency, but only by several mL.min-1.1.73m-2. Overestimation of inulin clearance by radioisotopic filtration markers was found in all normal subjects. No differences between markers were found in the coefficient of variation of clearances either between periods on a given study day (within-day variability) or between the two study days (between-day variability). The true test variability between days did not correlate with within-test variability. We conclude that the renal clearance of 99mTc-DTPA, 169Yb-DTPA, or 125I-iothalamate administered as a single IV or subcutaneous injection can be used to accurately measure GFR in subjects with renal insufficiency; use of the single injection technique may overestimate GFR in normal subjects

  3. Clearance of technetium-99m-DTPA and HRCT findings in the evaluation of patients with Idiopathic Pulmonary Fibrosis

    Directory of Open Access Journals (Sweden)

    Karkavitsas Nikolaos

    2006-02-01

    Full Text Available Abstract Background Clearance of inhaled technetium-labeled diethylenetriamine pentaacetate (99mTc-DTPA is a marker of epithelial damage and an index of lung epithelial permeability. The aim of this study was to investigate the role of 99mTc-DTPA scan in patients with Idiopathic Pulmonary Fibrosis (IPF. Our hypothesis is that the rate of pulmonary 99mTc-DTPA clearance could be associated with extent of High Resolution Computed Tomography (HRCT abnormalities, cell differential of bronchoalveolar lavage fluid (BALF and pulmonary function tests (PFTs in patients with IPF. Methods We studied prospectively 18 patients (14 male, 4 female of median age 67yr (range 55–81 with histologically proven IPF. HRCT scoring included the mean values of extent of disease. Mean values of these percentages represented the Total Interstitial Disease Score (TID. DTPA clearance was analyzed according to a dynamic study using a Venticis II radioaerosol delivery system. Results The mean (SD TID score was 36 ± 12%, 3 patients had mild, 11 moderate and 4 severe TID. Abnormal DTPA clearance half-time (t1/2 Conclusion Our data suggest that 99mTc-DTPA lung scan is not well associated with HRCT abnormalities, PFTs, and BALF cellularity in patients with IPF. Further studies in large scale of patients are needed to define the role of this technique in pulmonary fibrosis.

  4. Chromium-51-EDTA and technetium-99m-DTPA excretion for assessment of small bowel Crohn's disease

    International Nuclear Information System (INIS)

    O'Morain, C.; Chervu, L.; Milstein, D.M.; Das, K.M.

    1984-01-01

    In the present study, 4 patients with radiologically documented Crohn's disease were given 100 μCi of Cr-51-EDTA and 5 mCi of Tc-99m-DTPA together orally in 10ml of water, and urine was collected during the following 24 hr period. Sequential imaging of the stomach and the GI tract was done with a LFOV gamma camera at 10 min intervals until the activity cleared the small bowel. The images failed to show any localization of the activity in any disease process and no extraintestinal accumulation site was observed scintigraphically. Mean 24 hr urinary excretion for Tc-99m-DTPA was 4.8 +- 2.6% comparable to that of Cr-51-EDTA in these patients. This study suggests that a comparable oral dose of Tc-99m-DTPA could be substituted for Cr-51-EDTA as a far more readily available agent for documenting small bowel Crohn's disease by quantitative assessment of its urinary excretion

  5. The technetium-99m DTPA partition test in the diagnosis of tuberculous meningitis

    International Nuclear Information System (INIS)

    Von Wenzel, K.S.; Klopper, J.F.; Wasserman, H.J.

    1989-01-01

    Although the blood/cerebrospinal fluid (CSF) bromide concentration ratio is sensitive and specific in the diagnosis of tuberculous meningitis (TBM), bromide-82 is not always available since it is not generally used in nuclear medicine. The use of technetium-99m diethylenetriamine penta-acetic acid (DTPA) for a partition test was compared with that of 82 Br in 22 cases. Seven patients were diagnosed as having TBM, 9 patients had viral meningitis and 5 patients had septic meningitis. One normal control subject was also studied. Although the mechanism of transfer of substances across the blood-brain barrier as well as the factors affecting it are still unclear, both 82 Br and 99m Tc-DTPA cross the blood-brain barrier to a greater extent in TBM than in viral meningitis. Both tracers thus yield decreased serum/CSF concentration ratios in TBM. The accuracy of the 82 Br partition test was found to be 90,9% if a critical serum/CSF ratio of 1,3 was chosen, compared with 86,9% for the 99m Tc-DTPA partition test if a critical value of 3 was chosen. The use of 99m Tc D TPA offers various advantages, including general availability, lower cost and radiation dose per MBq, as well as the possibility of concomitant brain scintigraphy. 1 tab., 9 refs

  6. The determination of the radiochemical purity of 99Tcm-DTPA-HSA injection

    International Nuclear Information System (INIS)

    Yin Guangrong; Zhang Yan

    1996-01-01

    A simple, rapid analytical method of radiochemical purity for the 99 Tc m -DTPA-HSA injection is established. 99 Tc m (VII), 99 Tc m (IV) and labelled compound 99 Tc m -DTPA-HSA are separated by two systems of paper chromatography on Whatman No.1. The solvent of the system A is 85% methanol and that of the system B is water-95% alcohol-ammonium hydroxide (volume ratio is 5:2:1). 90 Tc m (IV) and labelled compound are located at the origin, while R f of 99 Tc m (VII) is about 0.4-0.5 in the system A. R f of 99 Tc m (VII) and labelled compound are about 0.7-0.8, while 99 Tc m (IV) is located at the origin in the system B

  7. Effect of milking efficiency on Tc-99 content of Tc-99m derived from Tc-99m generators

    International Nuclear Information System (INIS)

    Bonnyman, J.

    1983-01-01

    Tc-99m obtained by separation from its parent Mo-99 always contains Tc-99 produced by decay of Tc-99m and Mo-99. Factors effecting the Tc-99/Tc-99m ratios are discussed. An HPLC method has been developed to measure the 99 TcO 4- content of sodium pertechnetate from generators with a detection limit of 0.9 ng Tc-99 for a 500 μl/ aliquot of TcO 4- -99m. First eluates of 10 chromatograph-ic generators gave Tc-99/Tc-99m ratios ranging from 3.5-46 ng Tc/mCi Tc-99m measured at the time of milking. The measurements indicate that Tc-99/Tc-99m ratios high enough to cause adverse labelling effects could be found in 'instant pertechnetate' and in the first eluate from Tc-99m generators for the activities normally used in radiopharmaceutical production

  8. Quality control studies and biological evaluation of three locally produced renal pharmaceutical preparations: 99mTc-DTPA, 99mTc-GH and 99mTcDMSA

    International Nuclear Information System (INIS)

    Al-Azzawi, H. M. A.; Al-Nuzal, S. M.; Badi, J. M.

    2012-12-01

    Quality control (QC) studies of three locally produced renal preparation of 9 9mT c-DTPA, 9 9mT c-GH and 9 9mT c-DMSA, as a part of the production activity before the Gulf war. The radioanalytical studies were performed using Gel Chromatography column Scanning (GCS) technique, although there are other alternative techniques. These kits tested for radiochemical purity and the labeling yields were found to be excellent. The biological studies included the following parameters; organ distribution (in mice, rats and rabbits), blood clearance in rabbits and plasma protein binding in rats at different time intervals. The poor renal concentration of three agents in mice was significant at two time intervals . The tissue distribution of DTPA, GH and DMSA kits, which were stored at 37 O C for 30 days in mice after intravenous injection of the radioactivity at 5, 30 and 60 minutes. The blood retention of the renal agents was considerably low compared to those in rats and rabbits at the respective time intervals. The blood clearance of 9 9m 'Tc-DMSA was relatively slow and 9 9mT c-GH has rapid blood clearance identical with that of 9 9mt c-DTPA for the first 20 minutes but slower thereafter. The binding of DTPA, GH and DMSA with plasma protein was 5, and 95% at 1 hour respectively. Various amounts of tin (11) (as SnCl-2) were used in the kits with up to 10 times more of the usual dose for respective tin-complex and it was observed that there was no significant variation of the usual dose for respective tin-complex and its was observed that there was no significant variation of the organ distribution in mice. (Author)

  9. Donor evaluation of extended time 99mTcDTPA renal scintigraphy for added information to guide donor kidney selection: a technologist perspective

    International Nuclear Information System (INIS)

    Kale, Chanchala; Tarsaria, Sunita; Jaiswal, R.; Amrita; Roshni; Pallavi

    2010-01-01

    Full text: 99m Tc-DTPA renal scan exposes the patient to considerably less radiation and the images are of superior quality. In donor patients a short time renal scintigraphy to calculate GFR by gates formula is widely accepted in clinical practice. Apart from kidney GFR, renal scan gives added information regarding size, shape and position of kidney, perfusion, peaking time, peak to T 1/2 ratio, transit time, perfusion, split function, assessment of drainage pattern. Aim: The purpose of this study was to evaluate significance of extended time 99m Tc DTPA renogram for appropriate selection of donor kidney. Materials and Method: A retrospective study on 66 patients (female-40, male-26, age range - 22-70 years, mean 48±24) was carried out in our centre. Patients were adequately hydrated before the study. Diuretic intervention renal dynamic scintigraphy (F+10) was performed after administering 5mCi of DTPA intravenously. Sequential dynamic images (Phase I-2 sec/frame for 1 min, Phase II-1 min/frame for 29 min) were acquired posteriorly on GE Millennium VG gamma camera. Pre and post syringe counts were also taken. Standard protocol was used for processing. Along with other parameters GFR by Gates formula was obtained Result: GFR was found to be in the range of 68.7 ml/min - 135.8 ml/min. (mean GFR = 102.25 ml/min). It was found that in 50 patients (75%) both Kidney GFR was normal. Whereas in 2 patients (3.0%) global GFR was low. There were 7 patients (10.60%) in which pelvicalceal hold up was seen which adequately cleared with lasix. One patient ( 99m Tc-DTPA renal scintigraphy with diuretic (F+10, 30 min study) as a functional modality is significantly useful in the selection of donor kidney

  10. Evaluation of technetium-99m DTPA for localization of site of acute upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Mahajan, K.K.; Ericsson, S.; Nawaz, K.; Owunwanne, A.; Kouris, K.; Higazy, E.; Awdeh, M.

    1986-01-01

    Intravenous Tc-99m DTPA was evaluated in 34 patients with active upper gastrointestinal bleeding. Active bleeding was detected in 25 patients: nine in the stomach, 12 in the duodenum, and four from esophageal varices. No active bleeding was seen in nine patients (two gastric ulcers and seven duodenal ulcers). Results were correlated with endoscopic and/or surgical findings. All completely correlated except: 1) one case of esophageal varices in which there was disagreement on the site, 2) three cases of duodenal ulcers that were not bleeding on endoscopy but showed mild oozing on delayed images and 3) one case of gastric ulcer, in which no bleeding was detected in the Tc-99m DTPA study, but was found to be bleeding at surgery 24 hours later. The Tc-99m DTPA study is a reliable method for localization of upper gastrointestinal bleeding with an agreement ratio of 85%. This method also can be used safely for follow-up of patients with intermittent bleeding. It is less invasive than endoscopy, is easily repeatable, and has the same accuracy

  11. Production of kits for the labelling with 113sup(m)In and sup(99m)Tc, at the CNEA

    International Nuclear Information System (INIS)

    Palcos, M.C.; Kurcbart, Horacio; Nowotny, G.; Ramos, Elsa; Riesgo, J.G.; Mitta, A.E.A.

    1978-05-01

    The actual state of the production of radiopharmaceuticals in the form of reagents kits at the C.N.E.A. is described. This could allow the users to label compounds with sup(113m)In and sup(99m)Tc in an easy and reproducible way. At present, the following sets are provided routinarily a) To label with sup(99m)Tc: Albumin macroaggregates: calcium gluconate; antimonium sulfide colloid, sodium phytate; sodium calcium DTPA; seroalbumin; sodium pyrophosphate; sodium citrate. b) To label with sup(113m)In: albumin macroaggregates; PVP-bicarbonate; DTPA; human seroalbumin. Regarding products in a developping stage, we have: to labed with sup(99m)Tc: dimercapto-succinic acid, set for the labelling of human erythrocytes, set for sup(113m)In and sup(99m)Tc concentration and bleomicin; to label with sup(113m)In: EDTMP sup(99m)In. (author) [es

  12. Comparison of carrier-added [99mTc] EDTMP and carrier-free preparations of [99mTc] EDTMP and [99mTc] DPD

    International Nuclear Information System (INIS)

    Krcal, A.; Kletter, K.; Dudczak, R.; Pirich, C.; Mitterhauser, M.

    2002-01-01

    Full text: High uptake of bone-seeking radiopharmaceuticals in malignant bone lesions is a prerequisite for adequate bone scanning. Visual image analysis is impaired due to high soft-tissue activity with currently available [ 99m Tc]-EDTMP-kits. This study aimed to compare carrier-added [ 99m Tc]-EDTMP with carrier-free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD preparations in clinical routine. 15 μg and 150 μg perrhenic acid respectively were added to [ 99m Tc]-pertechnetate (>6 GBq in 3 ml phys. saline). The solution was then transferred into a vial, containing 1 mg of EDTMP, 3.6 mg stannous(II)chloride and 10 mg ascorbic acid under inert conditions. Under vigorous stirring the reaction mixture was heated to 45 o C for 10 min. After cooling down to room temperature the labelling mixture was sterile filtrated (millipore 0.22 μm). Quality control was performed using radio-ITLC (Whatman SG; acetone or ethanol: R f perrhenate/pertechnetate 0.87, colloid/product 0.05; phys. saline: R f colloid 0.00, perrhenate/pertechnetate and product 0.9) allowing rapid and efficient assessment of the product. Carrier free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD were prepared according to instructions of the manufacturer. Clinical studies were performed in 29 patients according to a routine bone scanning protocol by injecting 700-800 MBq of the respective tracer and whole body imaging 3 h thereafter. Radiochemical purity and radiochemical yield relied on various parameters such as concentration of carrier and reducing agent and reaction conditions (pH, reaction time, temperature). Means of the labelling yield were 22 % for the preparation using 150 μg of carrier (5 preparations), 80 % for the preparation using 15 μpg of carrier (10 preparations) and 91 % for the carrier free products (5 preparations). Radiochemical purity was >96 % in all experiments. Colloid was formed in very low amounts, and was completely removed by sterile filtration. In clinical studies quantitative analysis

  13. Comparison of sup(99m)Tc-MDP to sup(99m)Tc-pertechnetate by computerized quantitative joint scintigraphy

    International Nuclear Information System (INIS)

    Rekonen, A.; Moettoenen, T.; Oka, M.

    1982-01-01

    99mTc-pertechnetate was compared to 99mTc-MDP in joint pairs with asymmetric arthritis. Markedly elevated joint activity ratios (inflamed/uninflamed joint) were measured in all the joint pairs studied. In the joints affected by reactive arthritis and without roentgenologic changes the mean joint activity was the same with both tracers. A very high activity ratio with 99mTc-MDP was found in septic arthritis. In rheumatoid arthritis the sensitivity of 99mTc-MDP as an indicator of active arthritis seemed to be better than that of 99mTc-pertechnetate. Even in joints without erosions in roentgenograms the joint activity ratios were markedly elevated with 99mTc-MDP. This suggests, that high activity in 99mTc-MDP scanning might be prognostic of erosive joint changes. In this work a profile curve was used for quantitation differences between joints

  14. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  15. Pharmaceutical design and pharmacological characterization of Tc99m [99mTc] labelled somatostatin and gastrin analogues

    International Nuclear Information System (INIS)

    Guggenberg, E. von

    2004-10-01

    The development of regulatory peptide analogues radiolabelled with 99m Tc is of great interest for nuclear medicine applications, as 99m Tc shows very favourable imaging characteristics, such as low radiation burden to the patient, optimal image quality in SPECT, one-day-acquisition-protocol, availability on demand and cost effectiveness. In this work the principles of pharmaceutical design and preclinical pharmacological characterization of regulatory peptide analogues labelled with 99m Tc with possible application in tumour diagnosis are described. [ 99m Tc-EDDA-HYNIC0,Tyr3]octreotide ( 99m Tc-EDDA-HYNIC-TOC) is a promising new radiopharmaceutical with the potential to replace [ 111 In-DTPA0]octreotide in receptor scintigraphy of somatostatin receptor-positive tumours. Radiolabelling at high labelling yields and high specific activities could be obtained applying a coligand exchange labelling approach from tricine for EDDA under optimized conditions of pH, EDDA and stannous ion concentration. The resulting complex was characterized via HPLC, receptor binding and LC-MS. For the development of a freeze-dried kit formulation with long shelf-life, high stability of the final preparation and retained biological activity, the addition of bulking agent, the pH of the freeze-drying solution and the content of stannous chloride were of major importance. Different methods of radiochemical purity testing were evaluated to guarantee high quality of the preparation in a clinical setting, forming the basis for a further clinical evaluation of this promising new radiopharmaceutical. Radiolabelling of [D-Glu1]minigastrin (MG) with 99m Tc was studied applying two different labelling approaches. HYNIC-MG could be labelled using tricine and EDDA as coligands; and (Nalpha-His)Ac-MG was used as tridentate ligand for the 99m Tc carbonyl core. Stability experiments by HPLC analysis in PBS, serum, histidine- and cysteine-solutions as well as rat liver and kidney homogenates, receptor

  16. Clinical evaluation of hepatic scintigraphy using 99mTc-GSA

    International Nuclear Information System (INIS)

    Ishii, Katsumi; Nishiyama, Shogo; Nishimaki, Hiroshi; Tadokoro, Katsumi; Ikeda, Toshiaki; Matsubayashi, Takashi; Ishii, Kodo

    1992-01-01

    Functional hepatic imaging was performed using 99m Tc-DTPA-galactosyl human serum albumin ( 99m Tc-GSA), a radiolabeled ligand that reacts specifically to the asialoglycoprotein receptor that resides at the plasma membrane of hepatocytes, in 21 patients: five with chronic active hepatitis (CAH), 14 with compensative liver cirrhosis (LC), one with chronic inactive hepatitis and one with acute hepatitis. The former two diseases were mainly investigated. Serial liver images were acquired at the rates of 10 sec/frame for 0-5 min and 2 min/frame for 6-30 min after the injection of 99m Tc-GSA, and the images were compared with 99m Tc-phytase images in 2 patients with CAH and 11 with LC, and those with portal scintigrams using 123 I-iodoamphetamine (IMP) in 3 patients with LC. The images using 99m Tc-GSA were in better agreement with hepatic function than those using 99m Tc-phytase, and with the findings of portal scintigraphy using 123 I-IMP. LHL15 (liver/liver and heart radioactivities at 15 min after injection of 99m Tc-GSA) correlated with the hepaplastin test (r=0.978 in CAH, and r=0.544 in LC), indicators of hepatic reserve. These results suggest that liver scintigraphy using 99m Tc-GSA might be a useful method for evaluating liver function. (author)

  17. Clinical studies of alveolar-capillary permeability using technetium-99m DTPA aerosol

    International Nuclear Information System (INIS)

    Sundram, F.X.

    1995-01-01

    Soluble radioaerosols such as technetium-99m diethylene triamine pentacetate (DTPA) permit simple quantitative studies of alveolar-capillary permeability to be performed, since the submicronic aerosols are deposited mainly at the lung periphery and are cleared across the alveolar-capillary membrane. Regional alterations in permeability can also be noted using this radionuclide technique. We have measured the pulmonary epithelial permeability in normal subjects and the alteration in smokers, glue-sniffers, patients with inhalation burns, chronic obstructive pulmonary disease (COPD) and patients with lung metastases from thyroid cancer treated with radioiodine 131 I. In the normal volunteers, the time taken for 50% of inhaled 99m Tc DTPA to be cleared from the lungs (T1/2) was 66 minutes±1 sd of 12 mins. The smokers had a mean T1/2 of 20 mins±1 sd 4 min. In the hard-core glue-sniffing group, the majority were smokers who had stopped smoking and glue-sniffing for periods varying from 1 day to 42 days, and it was possible to note the changes in clearance times against period of abstinence. In the patients with inhalation burns, there was change in lung clearance arising from pulmonary epithelial damage; these patients showed increased rate of clearance (short T1/2) with mean T1/2 of 36 min±1 sd of 11 mins, while the retention images revealed regional lung damage in moderately severe inhalation burns. Twenty-four patients with COPD had inhalation scans done with Tc-99m tin colloid radioaerosol, and these images were compared with the perfusion lung scans done with 99m Tc macroaggregated albumin (MAA); in general the perfusion images matched the defects noted in the inhalation scans. The 99m Tc DTPA clearance rate in these patients was normal i.e. T1/2=78±14 mins. In the thyroid cancer patients with lung metastases, who had high doses of radioiodine treatment, the T1/2 values were normal or prolonged slightly, mean T1/2=76 min±23. (author)

  18. Labeling and stability of radiolabeled antibody fragments by a direct 99mTc-labeling method

    International Nuclear Information System (INIS)

    Pak, K.Y.; Nedelman, M.A.; Tam, S.H.; Wilson, E.; Daddona, P.E.

    1992-01-01

    The in vitro labeling and stability of 99m Tc-labeled antibody Fab' fragments prepared by a direct labeling technique were evaluated. Eight antibody fragments derived from murine IgG1 (N = 5), IgG2a (N = 2) and IgG3 (N = 1) isotypes were labeled with a preformed 99m Tc-D-glucarate complex. No loss of radioactivity incorporation was observed for all the 99m Tc-labeled antibody fragments after 24 h incubation at 37 o C. 99m Tc-labeled antibody fragments (IgG1, N = 2; IgG2a, n = 2; IgG3, N = 1) were stable upon challenge with DTPA, EDTA or acidic pH. Using the affinity chromatography technique, two of the 99m Tc-labeled antibody fragments displayed no loss of immunoreactivity after prolonged incubation in phosphate buffer up to 24 h at 37 o C. Bonding between 99m Tc and antibody fragments was elucidated by challenging with a diamide ditholate (N 2 S 2 ) compound. The Fab' with IgG2a isotype displayed tighter binding to 99m Tc in comparison to Fab' from IgG1 and IgG3 isotype in N 2 S 2 challenge and incubation with human plasma. The in vivo biodistribution of five 99m Tc-labeled fragments were evaluated in normal mice. (Author)

  19. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    Science.gov (United States)

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  20. The scintigraphy of sacroiliac joints. A comparison of 99mTc-DPD and 99mTc-MDP

    International Nuclear Information System (INIS)

    Lantto, T.

    1990-01-01

    The accumulation of 99m Tc-methylene diphosphonate ( 99m Tc-MDP) and 99m Tc-dicarboxypropane diphosphonate ( 99m Tc-DPD) in sacroiliac (si) joints was evaluated as a function of imaging time in 22 control patients and 5 patients with sacroiliitis. The controls were injected with either 99m Tc-DPD or 99m Tc-MDP (12 and 10 patients, respectively) and the patients with sacroiliitis with both agents within 5 days. Both the anterior and posterior views of the si joints were taken. The sacroiliac joint-to-sacrum (SI/S) ratio was calculated with the region of interest method. No statistically significant differences between these bone-seeking agents were found in the SI/S ratios of the control or the diseased patients. A clear overlap of indices (mean±SD) was found between the control patients and the patients with sacroiliitis. When the inflamed si joint was divided into three small adjacent areas and the SI/S ratios calculated for these areas, a statistically significant (P 99m Tc-DPD and in most patients injected with 99m Tc-MDP. In the posterior views, the significance was less marked. In every case, the inflamed part of the si joint was visible in the anterior views. The background subtraction had the greatest effect on the SI/S ratio of anterior images, but in the posterior views no significance was found. The low specificity of sacroiliac joint imaging must be taken into consideration when the results are interpreted. (orig.)

  1. Radiolabeling of human platelets using four radiopharmaceuticals with Tc-99m

    International Nuclear Information System (INIS)

    Portillo L, M.C.; Godoy, C.

    1991-01-01

    The present investigation work has been done in an evaluation of four different radiopharmaceuticals with Tin II (Glucoheptonate, Pyrophosphate, Citrate and DTPA), with the purpose of determining which one of the four would be obtained a higher rate of radiolabeling of platelets with Tc-99m. In order to evaluate the four radiopharmaceuticals it was procede to the separation and labeling of the human platelets. It was worked with samples of blood from five pacients, and the platelets from each one of them were labeled with the radiopharmaceuticals-Tc-99m. Then was observed a significant difference among the four radiopharmaceuticals studied, with a reliable level of 0.05 being the Glucoheptonate-Tc-99m the best to label platelets, obtaining with the same 50.23% of labeling efficiency, while for DTPA, Pyrophosphate and Citrate, It was obtained 33.42%, 29.82% and |2.62% respectively. Also, it was studied the biodistribution of the labeled platelets, using Glucoheptonate-Tc-99m as a radiopharamceutical. The biodistribution was studied in white mice at different times and it was founded that the place of biodistribution of the labeled platelets is given in greater percentage in the liver, spleen, lungs and kydneis. (Author)

  2. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  3. Use of /sup 99m/Tc diethylenetriaminepentaacetic acid for assessment of renal function in dogs with suspected renal disease

    International Nuclear Information System (INIS)

    Krawiec, D.R.; Twardock, A.R.; Badertscher, R.R. II; Daniel, G.B.; Dugan, S.J.

    1988-01-01

    The effectiveness of technetium /sup 99m/-labeled diethylenetriaminepentaacetic acid (/sup 99m/Tc DTPA) to assess renal function in 13 dogs with suspected renal disease was evaluated. Glomerular filtration rates (actual GFR) were determined on the basis of endogenous creatinine clearance. Predicted GFR were determined by using /sup 99m/Tc DTPA within 72 hours after the determination of creatinine clearance. The percentage of an IV administered dose of /sup 99m/Tc DTPA in the kidneys (percentage dose) was determined. Two equations were used to calculate predicted GFR, which were derived from previously reported linear regression analysis of inulin (In) and creatinine (Cr) GFR vs percentage dose /sup 99m/Tc DTPA in dog kidneys. The correlations of actual GFR vs predicted GFR (In) and actual GFR vs predicted GFR (Cr) were both r = 0.92. The dogs' mean actual GFR was 1.73 +/- 1.35 ml/min/kg. Their mean predicted GFR (In) and predicted GFR (Cr) were 1.92 +/- 1.42 ml/min/kg and 1.85 +/- 1.27 ml/min/kg, respectively. Therefore, /sup 99m/Tc DTPA can be used with high accuracy as an agent to predict GFR in dogs with suspected renal disease. The procedure for determining GFR by use of nuclear medicine was rapid and noninvasive and appeared to induce little stress in the animals evaluated

  4. Radiopharmacokinetic data for 99mTc-ABP - A new radiopharmaceutical for bone scanning: Comparison with 99mTc-MDP

    International Nuclear Information System (INIS)

    Murphy, Consuelo Arteaga de; Melendez-Alafort, Laura; Montoya-Molina, Carlos E.; Sepulveda-Mendez, Jesus

    1997-01-01

    Technetium-99m-labeled alendronate is a new radiopharmaceutical for bone scanning developed under strict quality control at the INNSZ. The purpose of this work was to compare the radiopharmacokinetic data and the dosimetry of 99m Tc-ABP and 99m Tc-MDP in 10 volunteers, after it was tested in laboratory animals. 99m Tc-ABP has shorter mean residence time (MRT) and t (1(2)) β; is less protein bound; has a higher renal clearance; smaller Vdss, and similar bone uptake at 1 and 2 h. 99m Tc-ABP gives less radiation exposure to the patient with a 740 MBq dose, and the quality of the bone scan is excellent. 99m Tc-ABP is a better radiopharmaceutical than 99m Tc-MDP for bone scanning

  5. The measurement of tracheo-bronchial mucociliary clearance with 99mTc-DTPA aerosol scintigraphy and its preliminary application in COPD patients

    International Nuclear Information System (INIS)

    Li, L.; Kuang, A.; Deng, H.; Li, X.

    2000-01-01

    Mucocoiliary clearance of respiratory channels is one of the important mechanisms guarding against retention of foreign particles within the lungs. Disorders of the mucociliary transport system play a major role among non-respiratory function in causing congenital and acquired bronchial disease. Thus, objective assay of the system is essential to recognizing and understanding abnormalities. In the present paper, a simple, noninvasive, and reliable in vivo method of monitoring mucociliary clearance function is reported. 18 healthy subjects and 32 COPD patients were studied with 99m Tc-DTPA aerosol scintigraphy. Monitoring was performed by visual inspection (cinescintigraphy, to observe the distribution of 99m Tc-DTPA particles and the movement of radiomucous 'hot bolus') and quantitative analysis (two indexes were utilized: the first is airway clearance ratio (ACR); the second is mucociliary clearance rate (MCC), i.e. speed of advances of mucous bolus, calculated reported by Zwas). Siemens 3700 SPECT, 64 X 64 byte mode, zoom 2. Sequential images (frame/60s) were obtained for 120 minutes. The deposition pattern of 99m Tc-DTPA particles in normal subjects was uniform. The deposition pattern in COPD patients demonstrated in general a centrally located distribution with major retention in the proximal airways. Four abnormal mucous transport patterns were regionally observed: stasis, regurgitation, straying and spiral or zigzag transport. Statistical analysis showed there was a significant difference of ACR between healthy subjects and COPD patients at different time points (P<0.05). The MCC in healthy subjects and COPD patients was 3.89±0.92 mm/min and 1.32±0.59 mm/min respectively. The method of assaying tracheo-bronchial mucociliary clearance reported here is simple and objective. It has not only the advantage of visual inspection and quantitative analysis, but also has a potential usefulness in studying other bronchial diseases and evaluating of therapeutic

  6. Relationship between severity of clinical symptoms and delay in gastric emptying in chronic gastritis; studied with sup(99m)Tc-DTPA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Rocha, A.F.G. da; Zuccaro, A.M.; Marquiotti, M.

    1986-06-01

    The gastric emptying time is studied with sup(99m)TC-DTPA-labeled mixed meal in 18 patients with chronic gastritis, all confirmed by endoscopic examination and biopsy. Emptying was slow in all such patients, but the intensity of symptomatology showed no correlation with gastric emptying half time.

  7. Relationship between severity of clinical symptoms and delay in gastric emptying in chronic gastritis; studied with sup(99m)Tc-DTPA scintigraphy

    International Nuclear Information System (INIS)

    Rocha, A.F.G. da; Zuccaro, A.M.; Marquiotti, M.

    1986-01-01

    The gastric emptying time is studied with sup(99m)TC-DTPA-labeled mixed meal in 18 patients with chronic gastritis, all confirmed by endoscopic examination and biopsy. Emptying was slow in all such patients, but the intensity of symptomatology showed no correlation with gastric emptying half time. (orig.)

  8. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    Science.gov (United States)

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  9. 99mTc-HYNIC-somatostatin analogues for imaging SST receptor positive tumours, preclinical evaluation and comparison with 111In-Octreotide

    International Nuclear Information System (INIS)

    Decristoforo, C.; Melendez-Alafort, L.; Sosabowski, J.K.; Mather, S.J.

    2001-01-01

    HYNIC-TOC and HYNIC-RC-160 were prepared and radiolabelled at high specific activities using tricine, EDDA and tricine/nicotinic acid as co-ligand systems. Radioligand binding assays were performed on membranes prepared from receptor-positive cell lines. Biodistribution and tumour uptake were determined in AR42J tumour bearing nude mice and compared to 99m Tc-MAG-3-RC-160 and 111 In-DTPA-Octreotide. Specific tumour uptake between 2.4 and 9.6%ID/g was found for the 99m Tc labelled HYNIC-conjugates compared to 0.2% for the 99m Tc-MAG-3-RC-160 and 4.3% ID/g for 111 In-DTPA-Octreotide. RC-160 conjugates showed lower tumour uptake and greater hepatobiliary excretion than TOC. Tricine as co-ligand showed higher levels of radioactivity in muscle, blood and liver, while tricine/NA produced significant levels of activity in the GI-tract. EDDA showed the most promising overall biodistribution profile with similar tumour: liver and GI-tract ratios to those obtained with 111 In-DTPA-Octreotide, lower ratios in blood and muscle but considerably higher tumour/kidney ratios. (author)

  10. 99mTc-MAG3 as a single modality investigative agent for evaluation of renal diseases in children

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Handa, R.; Bajpai, M.

    1998-01-01

    Optimal assessment of a child with congenital or acquired renal disease consists of quantitation of renal cortical and excretory function. This at present is routinely done with a 99m Tc-GHA/DMSA and 99m Tc-DTPA scans, respectively. This study was undertaken to assess if 99m Tc-MAG 3 can be utilized as a single modality investigation to provide adequate information about these functions. Sixteen children attending the pediatric urology clinic at All India Institute of Medical Sciences (AIIMS), New Delhi with a variety of renal disorders like posterior urethral valves, hydronephrosis vesicoureteral reflux etc. were included in the study. All the cases were subjected to 99m Tc-MAG 3 , 99m -DTPA and 99m Tc-GHA scans on separate occasions, but as close to one other as possible. The time required for the completion of a 99m Tc-MAG 3 renogram was only twenty minutes. 99m Tc-MAG 3 produced significantly better scintigraphic images of the kidneys and ureters, enabling differentiation between pelviureteric and vesicoureteric junction obstruction. Because of the abundance of photons in 99m Tc-MAG 3 , antegrade ureteric visualization was possible in nine renal units with active ureteric peristalsis appreciable in three renal units. Being a renal tubular agent, it gave a better assessment of renal health of the involved renal unit as compared to 99m Tc-DTPA, a glomerular filtration agent. Detection of renal scars as compared to 99m Tc-GHA showed a sensitivity of 69% and specificity of 93%. Amount of radioactivity required was consistently less than either GHA or DTPA scans. Use of 99m Tc-MAG 3 for renal functional evaluation may result in decreased radiation exposure and optional gamma camera utilization. Besides it is more cost-effective and may reduce the number of investigations that a child needs to be subjected to. It may be of immense value in a country like India where patients have to travel long distances to avail such investigations in a few, overworked nuclear

  11. Analysis of 99mTc-labeled radiopharmaceuticals by high-performance liquid chromatography

    International Nuclear Information System (INIS)

    Muto, Toshio

    1990-01-01

    High-performance liquid chromatography (HPLC) equiped with on line radiometric and optical detectors (i.e. radio-HPLC) have been applied to the radiochemical analysis of commonly-used 99m Tc-radio pharma ceuticals with a view point to check the radiochemical purities of the compounds. Chromatographic conditions were determined by examination of the types of column, mobile phase and pH. An aqueous size-exclusion (Shim-pack Diol-300) and reversed-phase column (Zorbax-ODS) were found to be suitable for 99m Tc-HSA and the other 99m Tc-agents, respectively. The analysis of low molecular weight 99m Tc-agents (e.g. 99m Tc-DTPA, 99m Tc-DMSA, 99m Tc-pyrophosphate, 99m Tc-phytic acid, 99m Tc-MDS, 99m Tc-HMDP) were done by reversed-phaseion pairing chromatography using a optimized mobile phase consisted on a mixture of 50 mM phosphate buffer (pH 7.0) and 2 mM TBA (tetra nbutyl) ammonium hydroxide) in 30 % methanol. The mobile phases for analysis of medium molecular weight 99m Tc-HSA were consisted of a mixture of 50 mM phosphate buffer (ph 7.0) in 30 % methanol, and a mixtures of 1 % SDS (sodium dodecyl sulfonate) in Tris buffer (pH. 7.0), respectively. It was apparent from the radio-chromatograms obtained from these chromatographic conditions, that impurity of 99m TcO 4 was observed in 99m Tc-pyrophosphate, 99m Tc-phytic acid, 99m Tc-MDP, 99m Tc-HMDP, and impurities of 99m Tc-labeled species and 99m TcO 4 , were observed in 99m Tc-HIDA, 99m Tc-HIDA, 99m Tc-HSA. The radiochemical impurities of the 99m Tc-radiopharmaceuticals were ranged between 90 and 100 %. From these results, radio-HPLC has been shown to be suitable method for analysis of 99m Tc-radiopharmaceuticals, with rapidity and excellent precision. (author)

  12. Positive end-expiratory pressure increases pulmonary clearance of inhaled 99mTc-DTPA in nonsmokers but not in healthy smokers

    International Nuclear Information System (INIS)

    Nolop, K.B.; Braude, S.; Royston, D.; Maxwell, D.L.; Hughes, J.M.B.

    1987-01-01

    Positive end-expiratory pressure (PEEP) is widely used in the treatment of severe pulmonary oedema, although its effects on the clearance of water and small solutes from alveolus to blood are not well characterized. We studied the effect of the application of 10 cmH 2 O of PEEP on the flux of inhaled 99 mTc-diethylene-triamine-penta-acetic acid (DTPA) from lung to blood in six healthy smoking and six nonsmoking subjects. The rate of flux was corrected for possible changes in pulmonary blood volume during PEEP by use of an intravenous injection of 99m Tc-DTPA. The baseline clearance rate (K,%.min -1 ) for nonsmokers was 1.48±0.12 (mean±SE) and increased to 2.40±0.29 during PEEP (p<0.05). In contrast, the mean clearance rate for smokers was 3.26±0.82 at baseline and 3.03±0.82 during PEEP (p=NS). The application of positive end-expiratory pressure appears to increase alveolar solute flux in nonsmokers but not in smokers, suggesting that the pathway for solute clearance in smokers is governed by different rate-limiting steps to those of nonsmokers

  13. Labelled Preformed liposomes with 99MTC-DTPA, 99 MTC-ECD, 99MTC-MDP and 99MTC-MIBI : Labelling procedures and stability studies

    International Nuclear Information System (INIS)

    Savio, E.O.; Teran, M.A.; Vales, M.E.; Frier, M.

    2004-01-01

    Liposomes labelled with gamma e miters like 99mTc, can be used for scintigraphic imaging to non-invasively track and quantify the distribution of liposomes in the body. In vitro studies were done to choose a suitable radiopharmaceutical (RF) to be attached to performed liposomes. 99mTc-Complexes (DTPA, ECD, MDP, MIBI) were used to label collagen liposomes. Commercial kits were labelled with 99mTc04-(TechnoNuclear). Quality controls of the RF were performed. Collagen liposomes suspended in saline 0.9% were incubated at 4.25.37 and 60 for 30 min. Efficiency of the labelling procedure was determined by gel filtration using Sephadex G25 (Pharmacia) and NaC10.9%. Samples of 100mL (74MBq), were seeded and fractions of 0.5mL were colleted and measured in an ionisation chamber (Capintec CRC). Stability of the labelled liposomes was assessed incubating 0.5mL, of the suspension with 1mL of human serum during 30 min at 37 . Dialysis was performed using dialysis bags of 64 K pore size and NaCI 0.9% at room temperature. Samples of the saline bath were collected at 30.60 and 90 min. and measured in a solid scintillation counter Ortec.Liposomes labelled with 99mTc-DTPA and 99mTcMIBI showed a labelling efficiency of 80%; liposomes incubated with 99mTc-MDP were labelled in a 50% and 99mTc-ECD did not bind to liposomes in the conditions of study. Incubation of labelled liposomes with human serum showed 50% of strong binding to the plasmatic proteins for 99mTc-DTPA but low values (5%) for the other specimens. Labelled liposomes were achieved, with different RF, showing a suitable in vitro stability to perform in vivo studies

  14. Detection of gastrointestinal blood loss with 99mTc-labeled, heat-treated red blood cells

    International Nuclear Information System (INIS)

    Som, P.; Oster, Z.H.; Atkins, H.L.; Goldman, A.G.; Sacker, D.F.; Harold, W.H.; Fairchild, R.G.; Richards, P.; Brill, A.B.

    1981-01-01

    Studies in dogs showed that heat-treated 99mTc-labeled red blood cells (HT/RBC) afford a highly sensitive means of detecting gastrointetinal bleeding as low as 0.12 ml/min., which could not be seen with unheated 99mTc-RBC, 99mTc-sulfur colloid, or 99mTc-DTPA. In addition, as the right upper quadrant and epigastrium remained free of activity, only one fifth to one tenth of the dose of 99mTc was needed. The safety of HT/RBC in humans has been documented, and the experiments in dogs suggest that it may have advantages over other agents in detecting gastrointestinal bleeding

  15. /sup 99m/Tc-aminohexylidendiphosphonate and /sup 99/mTc-Pyrophosphate in the scintigraphic diagnosis of experimental cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Kafka, P; Mazurova, Y; Hadas, L; Vizda, J; Palicka, V; Grossman, V

    1987-10-01

    Experimental cardiomyopathy was provoked in 24 dogs with high intravenous doses of adrenaline and theophylline. These lesions were studied by means of the new agent /sup 99m/Tc-AHDP and /sup 99m/Tc-PYP in comparison. Cardiomyopathy could be imaged as early as 4 h after the onset of involvement but not later than 7 days. A maximum accumulation occurred in lesions 24 h old, /sup 99m/Tc uptake in the myocardium was graded scintigraphically, /sup 99m/Tc-AHDP was accumulated in the altered myocardium to a greater extent than /sup 99m/Tc-PYP. Scintigraphic findings were in good agreement with plasma levels of creatine-kinase. A comparison with histology demonstrated that the maximum accumulation of radiopharmaceuticals occurred at the time when the development of myocardium involvement reached the stage of myocytolysis.

  16. 99mTc labelled peptide for imaging of peripheral receptors

    International Nuclear Information System (INIS)

    Mishra, A.K.; Mishra, P.; Chuttani, K.; Sharma, R.K.; Lazar Mathew, T.

    2001-01-01

    Conjugates of somatostatin analogues, RC-160 with different bifunctional chelators to label with 99m Tc, were synthesized. Conjugates with hydrazinonicotinamide (HYNIC) and compounds (benzoyl MAG-3 and CITC-DTPA) were prepared on a small scale with high purity and evaluated as different types of chelators on RC-160. Stability studies performed under physiological conditions showed high stability. Peptide conjugates could be labelled at high specific activities (307inCi/umol) with 99m Tc and different transchelator were used for the HYNIC conjugates. The resulting radiolabelled with ( 99m Tc and 1251) complexes were highly stable and showed binding affinity to somatostatin receptors in the nanomolar range. The radioconjugates were administered to rabbits and mice in order to study their in vivo stability, biokinetics and biodistribution. (author)

  17. In Vitro Evaluation of Tc-99m Radiopharmaceuticals for Gastric Emptying Studies

    Directory of Open Access Journals (Sweden)

    Türkan Ertay

    2014-02-01

    Full Text Available Objective: Gastrointestinal motility and functional motility disorders causing either delayed or accelerated gastric emptying (GE may result in similar symptoms including nausea, vomiting, early satiety, fullness, bloating, and abdominal discomfort or pain. Hence, it is important to evaluate patients for both rapid and delayed GE in the same test. The gold standard technique to measure GE is scintigraphy by radiolabeled test meals. The aim of this study was to test alternative Tc-99m agents to label eggs as the solid meal and compare to Tc-99m sulfur colloid (SC for gastric emptying studies. Methods: In search of alternative agents for gastric emptying studies, we mixed and fried eggs with four different particulate compounds (Tc-99m labeled SC, tin colloid, nanocolloid and MAA, as well as with free pertechnetate and Tc-99m DTPA. We then measured the stability of these compounds in simulated gastric juice. Results: Our experiments demonstrated that in addition to Tc-99m sulfur colloid;Tc-99m MAA, Tc-99m nanocolloid and Tc-99m tin colloid also appear to make stable complexes with eggs in acidic environment. Conclusion: Therefore, these agents may be used for gastric emptying studies which could be more practical in routine conditions.

  18. Clinical comparison of diisopropyl-IDA Tc 99m and diethyl-IDA Tc 99m for evaluation of the hepatobiliary system

    International Nuclear Information System (INIS)

    Klingensmith, W.C.; Fritzberg, A.R.; Spitzer, V.M.; Kuni, C.C.; Shanahan, W.S.

    1981-01-01

    Thirty-one patients with a wide range of hepatobiliary function and clinical diagnoses were studied with both diisopropyl-IDA Tc 99m and diethyl-IDA Tc 99m. Images were similar except for an increased liver-to-kidney ratio with diisopropyl-IDA Tc 99m (p less than 0.01) and a tendency toward an increased liver-to-background ratio at five minutes with diisopropyl-IDA Tc 99m (p greater than 0.05). Quantification of the relative hepatocyte extraction efficiency indicated a 16% higher extraction efficiency for diisopropyl-IDA Tc 99m (p greater than 0.05). Cumulative three-hour urine collections following injection demonstrated no significant difference in renal excretion in patients with normal total serum bilirubin levels. Both radiopharmaceuticals demonstrated increasing renal excretion with increasing total serum bilirubin levels; however, renal excretion of diisopropyl-IDA Tc 99m increased more slowly than excretion of diethyl-IDA Tc 99m (p less than 0.01). We conclude that, while the overall differences between these two radiopharmaceuticals are small, diisopropyl-IDA Tc 99m is superior because of a lower renal excretion rate in patients with decreased hepatocyte function

  19. Using radioisotopes compounds (99mTc-infecton and 99mTcHIG) in evaluating and examination of pulmonary tuberculosis patients

    International Nuclear Information System (INIS)

    Moustafa, H. M.; Abdul-Hakeem, O.; Mohammad, K.; Briton, K.

    2000-01-01

    This study examined 40 patients: 34 have pulmonary tuberculosis, 3 have pneumonitis, 2 have lung cancer, and one has bilharziasis. All patients have been imaged using radioisotopes compounds (99mTc-infecton and 99mTcHIG) and after 1 hour and 4 hours of patients injection.Using 99mTc-infecton gave positive results in 30 pulmonary tuberculosis patients out of 34, the 3 pneumonitis patients, while using 99mTcHIG gave positive results in 27 pulmonary tuberculosis patients including the 3 pneumonitis patients. Both 99mTc-infecton and 99mTcHIG gave negative results with the lung cancer patients and unreal positive results with the bilharziasis patient. It has been found that the sensitivity and accuracy in the examinations using 99mTc-infecton were 88%, 93%, and 85.7% respectively in comparison with using 99mTcHIG where the values were 70.6%, 91%, and 68.5% respectively. Continuing examination and monitoring of 18 tuberculosis patients for 2-18 months with anti-pulmonary tuberculosis treatment, showed complete response of 12 patients using 99mTc-infecton, and 8 by using 99mTcHIG. As a result, 99mTc-infecton can be used for examining pulmonary tuberculosis patients

  20. Production and clinical evaluation of 99mTc-octreotide

    International Nuclear Information System (INIS)

    Fettich, J.; Kolenc-Peitl, P.

    2004-01-01

    Full text: Due to advantages of 99m-Tc labelled radiopharmaceuticals we examined the feasibility of producing 99m-Tcoctreotide in our laboratory and compare the results with 111-In-octreotide in the same patients. Keeping constant amount of components without exceeding amount of the peptide used, preparation of 99m-Tc-ethylendiaminediacetic- acidhydrazinonicotinamide-D-Phe1,Tyr3-octreotide (99m-Tc EDDA/HYNIC-TOC) was achieved. Radiochemical purity was tested using high-pressure liquid chromatography for 24 hours. In vitro stability testing of the product showed that radiochemical purity remained above 95% for 24 hours and the radiopharmaceutical was found suitable for human use. 5 - 10 μg of the peptide labelled with 550-650 MBq of 99m-Tc was prepared for each patient. 32 patients with clinically suspicious or confirmed carcinoid were investigated with 550 - 650 MBq 99m-Tcoctreotide prepared in our laboratory followed by 110 MBq 111-In-octreotide (Octreoscan, Mallinkrodt). Whole body scintigraphy and abdominal SPECT were performed 4 and 20 hrs after injection of respective radiopharmaceutical. In all patients both studies were acquired within 5 days. All patients gave informed consent for the study as required by Ethics committee. No abnormal tracer uptake was seen anywhere in the body in 12 patient with either of the radiopharmaceuticals. These were used to assess normal distribution of both radiopharmaceuticals. Normal accumulation was seen in case of both radiopharmaceuticals in the spleen, kidneys, liver and gallbladder. Biliary activity was seen in the gut in patients that were not well prepared for the study. There was significantly less activity seen in the kidneys in case of 99m-Tc-octreotide. This could be explained by higher hydrophilicity of the 99m-Tc-EDDA/HYNEC-TOC molecules as compared with 111-In-DTPA-octreotide. 20 patients with confirmed carcinoids showed abnormal uptake but without any difference in distribution of the two radiopharmaceuticals

  1. Preparation and stability of the {sup 99m} Tc-HNE{sub 2} radiopharmaceutical; Preparacion y estabilidad del radiofarmaco {sup 99m} TC-HNE{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Estrada T, J

    2002-07-01

    A radiopharmaceutical is all substance containing a radioactive atom inside of its structure and what because of its pharmaceutical form, quantity and quality of radiation can be administered in the human beings with diagnostic or therapeutic aims. With the purpose to developing effective radiopharmaceuticals it is necessary to pick carefully the appropriate radionuclide in combination with the In vivo localization and the pharmacon kinetic properties of the carrier molecule. The peptides are designed by the nature to stimulate, regulate or inhibit numerous life functions, they act mainly as information transmitters and activity coordinators of several tissues in the body; it has been found that such substances are present in cells and in the body fluids in quantities extremely small, therefore the peptides have been considered as ideal agents for therapeutic applications. Elastase of human neutrophylls is a 29 kDa protease which is produced in high levels inside the neutrophyll and it is released as response for an inflammatory stimulus in infection/inflammation places. Once it liberated is quickly inhibited by the anti elastase {alpha} tripsine (HNE-2) peptide. Therefore, the neutrophylls elastase is considered as a target to obtain In vivo images of inflammatory/infectious processes by the intravenous application of {sup 99m} Tc-HNE-2. The objective of this work was to develop a labelling method with {sup 99m} Tc for the inhibitor peptide of the human neutrophyll elastase (HNE-2). Likewise, for evaluating its In vivo and In vitro stabilities. The methodology which was followed as first step to conjugate the (HNE-2) peptide with the bi chelating agents HYNIC and DTPA capable to chelate the {sup 99m} Tc metal. Therefore the attachment reactions to the peptide were realized starting from the NHS and HYNIC and the DTPA anhydride in buffer of 0.1 M, pH= 9.0/DMF (10:1) bicarbonates with a molar relation peptide/bi chelating agent 1:5. For the purification of the

  2. Measuring hepatic functional reserve using T1 mapping of Gd-EOB-DTPA enhanced 3T MR imaging: A preliminary study comparing with 99mTc GSA scintigraphy and signal intensity based parameters.

    Science.gov (United States)

    Nakagawa, Masataka; Namimoto, Tomohiro; Shimizu, Kie; Morita, Kosuke; Sakamoto, Fumi; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Shiraishi, Shinya; Yamashita, Yasuyuki

    2017-07-01

    To determine the utility of liver T1-mapping on gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) enhanced magnetic resonance (MR) imaging for the measurement of liver functional reserve compared with the signal intensity (SI) based parameters, technetium-99m-galactosyl serum albumin ( 99m Tc-GSA) scintigraphy and indocyanine green (ICG) clearance. This retrospective study included 111 patients (Child-Pugh-A 90; -B 21) performed with both Gd-EOB-DTPA enhanced liver MR imaging and 99m Tc-GSA (76 patients with ICG). Receiver operating characteristic (ROC) curve analysis was performed to compare diagnostic performances of T1-relaxation-time parameters [pre-(T1pre) and post-contrast (T1hb) Gd-EOB-DTPA], SI based parameters [relative enhancement (RE), liver-to-muscle-ratio (LMR), liver-to-spleen-ratio (LSR)] and 99m Tc-GSA scintigraphy blood clearance index (HH15)] for Child-Pugh classification. Pearson's correlation was used for comparisons among T1-relaxation-time parameters, SI-based parameters, HH15 and ICG. A significant difference was obtained for Child-Pugh classification with T1hb, ΔT1, all SI based parameters and HH15. T1hb had the highest AUC followed by RE, LMR, LSR, ΔT1, HH15 and T1pre. The correlation coefficients with HH15 were T1pre 0.22, T1hb 0.53, ΔT1 -0.38 of T1 relaxation parameters; RE -0.44, LMR -0.45, LSR -0.43 of SI-based parameters. T1hb was highest for correlation with HH15. The correlation coefficients with ICG were T1pre 0.29, T1hb 0.64, ΔT1 -0.42 of T1 relaxation parameters; RE -0.50, LMR -0.61, LSR -0.58 of SI-based parameters; 0.64 of HH15. Both T1hb and HH15 were highest for correlation with ICG. T1 relaxation time at post-contrast of Gd-EOB-DTPA (T1hb) was strongly correlated with ICG clearance and moderately correlated HH15 with 99m Tc-GSA. T1hb has the potential to provide robust parameter of liver functional reserve. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Clinical evaluation of hepatic scintigraphy using sup 99m Tc-GSA

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Katsumi; Nishiyama, Shogo; Nishimaki, Hiroshi; Tadokoro, Katsumi; Ikeda, Toshiaki; Matsubayashi, Takashi; Ishii, Kodo (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1992-06-01

    Functional hepatic imaging was performed using {sup 99m}Tc-DTPA-galactosyl human serum albumin ({sup 99m}Tc-GSA), a radiolabeled ligand that reacts specifically to the asialoglycoprotein receptor that resides at the plasma membrane of hepatocytes, in 21 patients: five with chronic active hepatitis (CAH), 14 with compensative liver cirrhosis (LC), one with chronic inactive hepatitis and one with acute hepatitis. The former two diseases were mainly investigated. Serial liver images were acquired at the rates of 10 sec/frame for 0-5 min and 2 min/frame for 6-30 min after the injection of {sup 99m}Tc-GSA, and the images were compared with {sup 99m}Tc-phytase images in 2 patients with CAH and 11 with LC, and those with portal scintigrams using {sup 123}I-iodoamphetamine (IMP) in 3 patients with LC. The images using {sup 99m}Tc-GSA were in better agreement with hepatic function than those using {sup 99m}Tc-phytase, and with the findings of portal scintigraphy using {sup 123}I-IMP. LHL15 (liver/liver and heart radioactivities at 15 min after injection of {sup 99m}Tc-GSA) correlated with the hepaplastin test (r=0.978 in CAH, and r=0.544 in LC), indicators of hepatic reserve. These results suggest that liver scintigraphy using {sup 99m}Tc-GSA might be a useful method for evaluating liver function. (author).

  4. Evaluation of renal function using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Takayama, Teruhiko; Aburano, Tamio; Shuke, Noriyuki

    1993-01-01

    The utility of 99m Tc-mercaptoacetyltriglycine (MAG3) was studied clinically. In the renography obtained with 99m Tc-MAG3, the abdominal aorta and the common iliac arteries were clearly visualized in the vascular phase. Due to less background activity and high target to background ratio, the quality of 99m Tc-MAG3 image was superior to that of 123 I-OIH or 99m Tc-DTPA image. The parameters on the renogram including T max , T 2/3 , and T 1/2 were compared. The correlation of T max and T 2/3 or T 1/2 were not significant between 99m Tc-MAG3 and 123 I-OIH. Another parameter of C 20 /C max , where C 20 and C max are renal activities at 20 min after injection and at T max respectively, showed an excellent correlation between 99m Tc-MAG3 and 123 I-OIH. Using C 20 /C max , pattern of renogram can be characterized numerically. Concerning the relation between C 20 /C max and renogram pattern, standard renogram pattern showed the C 20 /C max value of less than 0.4, while hypofunctioning pattern showed more than 0.5. The correlation coefficient between the renal uptake of 99m Tc-MAG3 and 123 I-OIH was 0.880 with a correlation plot: 'Y=1.16X-0.043', where X and Y represent renal uptake of 99m Tc-MAG3 and 123 I-OIH, respectively. It can be concluded that 99m Tc-MAG3 is a useful renal imaging agent as an alternative to 123 I-OIH, in order to evaluate the proximal tubular function and calculate ERPF. (author)

  5. Pharmacological study of 99mTc-CO-MIBI, a new mycoardial perfusion imaging agent comparison to 99mTc-MIBI

    International Nuclear Information System (INIS)

    Zhao Jiandong; Wang Jincheng; Mi Hongzhi

    2004-01-01

    For many years, 99m Tc-MIBI has been widely used for the diagnosis of ischemic heart disease. Although it has been regarded as a successful myocardial imaging agent, it has a notable defect of high liver radioactivities due to high uptake and slowly excrete. Recently, researchers had developed a new intermediate [ 99m Tc(CO) 3 (OH 2 ) 3 ] + , considering 99m Tc-MIBI excellent biodistribution, they synthesized a new class of compound- 99m Tc-CO-MIBI with [ 99m Tc(CO) 3 ] + core and ligand MIBI. Previous studies have preliminary demonstrated the following favorable properties: rapid blood-pool clearance, high myocardial extraction and rapid clearance kinetics from liver that indicated 99m Tc-CO-MIBI a promising new myocardial perfusion imaging agent. Furthermore, researchers separated the compound by changing liquid pH value and prepared single alkaline component 99m Tc-CO-MIBI. The pharmacological experiments in rat have provided better results on its biodistribution in vivo and much faster clearance kinetics from liver compared to 99mTc-MIBI. To evaluate the potential application of 99m Tc-CO-MIBI, further investigations are necessary to determine the evidence for enhanced ability in clinical decision making as a novel new myocardial perfusion imaging agent. Objective: Here, perform pharmacological experiment of 99m Tc-CO-MIBI, a new technetium-99m-labeled myocardial imaging agent compared to 99m Tc-MIBI in canines. To identify whether it is feasible in clinical application as a novel myocardial imaging agent, or not. Results: Accordingly, prepared the single alkaline component of 99m Tc-CO-MIBI. The complex was stable up to at least 7 hours after synthesized in vitro at either room temperature or 37 degree C water bath. Labeling yield and radiochemical purity (RCP) of the complex were evaluated by TLC and HPLC, the labeling percent was 93%-97% and the RCP was over 90%. Then administer 555MBq to every dog each times. A total of 5 dogs were involved. The data of

  6. An analysis of 'obstructive type' renography cases in 99mTc-DTPA renal dynamic imaging

    International Nuclear Information System (INIS)

    Wang Xinhui

    1991-01-01

    99m Tc-DTPA renal dynamic imaging and computed renography were performed in 61 cases. Renal blood perfusion imaging was also performed in some cases. Renography curves, which did not decrease in 20 min on all 61 cases (90 kidneys), are analysed in combination with renal dynamic imaging and renal perfusion imaging. 11 cases (12 kidneys) are only obstructive. 24 cases (32 kidneys) are obstructive and renal function impaired. Other 26 cases (46 kidneys) are renal function impaired or blood perfusion insufficient, but are not obstructive. The result demonstrated that the obstructive type renography may be obstructive or may be renal function impaired or blood supply insufficient. An analysis of renography in combination with renal dynamic imaging and blood perfusion imaging is more accurate than renography alone

  7. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Bair, H.J.; Platsch, G.; Wolf, F. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Nuclear Medicine; Guenter, E.; Becker, D. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 1; Rupprecht, H.; Neumayer, H.H. [Erlangen-Nuernberg Univ., Erlangen (Germany). Dept. of Internal Medicine 4

    1997-08-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [Deutsch] Ziel der Studie war es, das

  8. Detection of gastrointestinal blood loss with /sup 99m/Tc-labeled, heat-treated red blood cells

    International Nuclear Information System (INIS)

    Som, P.; Oster, Z.H.; Atkins, H.L.; Goldman, A.G.; Sacker, D.F.; Harold, W.H.; Fairchild, R.G.; Richards, P.; Brill, A.B.

    1981-01-01

    Studies in dogs showed that heat-treated /sup 99m/Tc-labeled red blood cells (HT/RBC) afford a highly sensitive means of detecting gastrointestinal bleeding as low as 0.12 ml/min, which could not be seen with unheated /sup 99m/Tc-RBC, /sup 99m/Tc-sulfur colloid, or /sup 99m/Tc-DTPA. In addition, as the right upper quadrant and epigastrium remained free of activity, only one fifth to one tenth of the dose of /sup 99m/Tc was needed. The safety of HT/RBC in humans has been documented, and the experiments in dogs suggest that it may have advantages over other agents in detecting gastrointestinal bleeding

  9. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  10. Preparation and stability of the 99m Tc-HNE2 radiopharmaceutical

    International Nuclear Information System (INIS)

    Estrada T, J.

    2002-01-01

    A radiopharmaceutical is all substance containing a radioactive atom inside of its structure and what because of its pharmaceutical form, quantity and quality of radiation can be administered in the human beings with diagnostic or therapeutic aims. With the purpose to developing effective radiopharmaceuticals it is necessary to pick carefully the appropriate radionuclide in combination with the In vivo localization and the pharmacon kinetic properties of the carrier molecule. The peptides are designed by the nature to stimulate, regulate or inhibit numerous life functions, they act mainly as information transmitters and activity coordinators of several tissues in the body; it has been found that such substances are present in cells and in the body fluids in quantities extremely small, therefore the peptides have been considered as ideal agents for therapeutic applications. Elastase of human neutrophylls is a 29 kDa protease which is produced in high levels inside the neutrophyll and it is released as response for an inflammatory stimulus in infection/inflammation places. Once it liberated is quickly inhibited by the anti elastase α tripsine (HNE-2) peptide. Therefore, the neutrophylls elastase is considered as a target to obtain In vivo images of inflammatory/infectious processes by the intravenous application of 99m Tc-HNE-2. The objective of this work was to develop a labelling method with 99m Tc for the inhibitor peptide of the human neutrophyll elastase (HNE-2). Likewise, for evaluating its In vivo and In vitro stabilities. The methodology which was followed as first step to conjugate the (HNE-2) peptide with the bi chelating agents HYNIC and DTPA capable to chelate the 99m Tc metal. Therefore the attachment reactions to the peptide were realized starting from the NHS and HYNIC and the DTPA anhydride in buffer of 0.1 M, pH= 9.0/DMF (10:1) bicarbonates with a molar relation peptide/bi chelating agent 1:5. For the purification of the conjugate the solid phase

  11. Comparison of 99m-Tc-MDP and 99m-Tc-MIBI whole body scans for diagnosis of widespread skeletal metastases

    International Nuclear Information System (INIS)

    Ansari, M.; Hoshiar, A.; Mortazavi, S.H.

    2002-01-01

    Skeletal metastasis is one of the most important disabling complications of the malignant diseases. As in general, the survival of patients with osteometastatic lesions is relatively long, an early diagnosis can lead to improve the patient's life, both quantitatively and qualitatively and prevent exacerbation of the disease and disabling complications. In this study 22 patients with established diagnosis of malignant disease and clinical manifestations of skeletal metastasis were evaluated both with 99 m-Tc-MIBI and 99 m-Tc-MDP whole body scans, in two separate phases. Patient's diagnosis were as following: small round cell tumor, breast carcinoma. Nasopharynx carcinoma and multiple myeloma. In the first phase of the study a whole body bone scan was performed by IV injection of 740MBq 99 m-Tc-MDP. After a period of 1 week a whole body scan carried out by 99 m-Tc-MDP for all the patients. No treatment such as radiation therapy ar chemotherapy was done in this 1 week interval. The number and intensity of the scan findings were compared visually, according to the three- phase staging, subsequently. whole body survey with 99 m-Tc-MDP in 14 out 22 patient were positive demonstrating only 44.4% of body lesions established on whole body bone scan with 99 m-Tc-MDP. The mean value of intensity of radiotracer uptake was around 1.5+ (mild to moderate ). on the other hand in 7 patients with positive 99 m-Tc-MDP scan some hidden soft tissue lesions ( mostly lymph nodes) were detected with intensity of 2+. So this study shows that whole body bone scan is preferable for detection of widespread metastasis comparing with 99 m-Tc-MDP whole body scan. the significance of 99 m-Tc-MDP scan is mainly limited to some equivocal of soft tissue lesions

  12. Determination of the mean transit time for the transport of aerosolized 99mTc-DTPA across the pulmonary epithelial membrane. A plasma sample method

    DEFF Research Database (Denmark)

    Groth, Sofie; Lassen, N A; Rossing, Niels Nygaard

    1988-01-01

    During the last decade it has been customary to estimate pulmonary epithelial permeability (P-P) as the pulmonary clearance of inhaled nebulized 99mTc-DTPA from a time-activity (t-a) curve registered externally by monitoring over the chest. The t-a curve, however, is not defined by the degree of ...

  13. Comparison of four technetium-99m radiopharmaceuticals for detection and localization of gastrointestinal bleeding in a sheep model

    International Nuclear Information System (INIS)

    Owunwanne, A.; Al-Wafai, I.; Vallgren, S.; Sadek, S.; Abdel-Dayem, H.M.; Yacoub, T.

    1988-01-01

    Four Tc-99 radiopharmaceuticals, Tc-99m sulphur colloid, Tc-99m red blood cells (RBCs), Tc-99m mercaptoacetyltriglycine (MAG3), and Tc-99m DTPA, were studied in an experimental animal model for detection and localization of gastrointestinal (GI) bleeding site in both the upper and lower abdomen. With Tc-99m sulphur colloid and Tc-99m RBCs, it was possible to detect and localize the GI bleeding site in the lower abdomen. With Tc-99m MAG3, it was possible to visualize the bleeding site in both the upper and lower abdomen. However, Tc-99m MAG3 is partially excreted by the liver into the bile, hence it will be difficult to use Tc-99m MAG3 to localize the GI bleeding site in the lower abdomen. With Tc-99m DTPA, it was possible to detect and localize the GI bleeding site simultaneously in both upper and lower abdomen. The overall background radioactivity was reduced considerably by diuresis with frusemide and catheterization of the urinary bladder

  14. Comparative biological evaluation between 99mTc tricarbonyl and 99mTc-Sn(II) levosalbutamol as a β2-adrenoceptor agonist

    International Nuclear Information System (INIS)

    Sanad, Mahmoud H.; Borai, Emad H.

    2015-01-01

    This study describes the comparison between 99m Tc-tricarbonyl and 99m Tc-Sn (II) levosalbutamol as a β 2 -adrenoceptors radiopharmaceutical and evaluation of their different biological characteristics using experimental animals. Levosalbutamol was labeled firstly with 99m Tc in the presence of SnCl 2 . 2H 2 O as a reducing agent under the optimum conditions: pH 8, 50 μg SnCl 2 . 2H 2 O, room temperature, 40 μg levosalbutamol and 30 min reaction time to give a maximum radiochemical yield of 98 ± 0.1%. The obtained 99m Tc-levosalbutamol was stable for a time up to 8 h. Secondly, 99m Tc-tricarbonyl ([ 99m Tc(CO) 3 (H 2 O) 3 ] + ) levosalbutamol was prepare under 30 min heating at 100 C. Labeling yield and stability were analyzed by high performance liquid chromatography (labeling yield >99% and stability for 8 h). Biodistribution investigation showed that, the maximum uptake ratio of the 99m Tc-levosalbutamol ( 99m Tc-Lev) between lung and heart was 2.34 ± 0.62 % of the injected activity/g tissue organ, at 30 min post-injection. But in case of 99m Tc-tricarbonyl levosalbutamol ( 99m Tc-tricarbonyl Lev) the maximum uptake ratio was 3.6 ± 0.11 of the injected activity/g tissue organ, at 30 min post-injection. This indicates that 99m Tc-tricarbonyl levosalbutamol was more selective for lung β 2 -adrenoceptors than 99m Tc-levosalbutamol. These results introduce 99m Tc-tricarbonyl levosalbutamol as a novel potential radiopharmaceutical for lung imaging.

  15. Ozone-induced changes in the pulmonary clearance of (99m)Tc-DTPA in man

    International Nuclear Information System (INIS)

    Kehrl, H.R.; Vincent, L.M.; Kowalsky, R.J.; Horstman, D.H.; O'Neil, J.J.

    1988-05-01

    Ozone is a respiratory irritant that has been shown in animals to increase the premeability of the respiratory epithelium. In the study the authors have recently reported that respiratory epithelial permeability was similarly affected in eight healthy non-smoking young men exposed to ozone (ARRD, 135 (1987) 1124-8). Permeability was evaluated by determining the pulmonary clearance of inhaled aerosolized 99mTc-DTPA with sequential posterior lung imaging by a computer-assisted gamma camera. In a randomized crossover design, 16 young men were exposed for 2 h to purified air and 0.4 ppm ozone while performing intermittent high intensity treadmill exercise; forced vital capacity (FVC) was measured before and at the end of exposures. The results demonstrate that ozone exposure increased respiratory epithelial permeability. Such an increase may be a manifestation of direct ozone-induced epithelial-cell injury, lung inflammation, or both

  16. Measurement of Regional and Global Pulmonary Clearance of 99mTc-DTPA (Demethylamitriptylene-Acetate): An Index of Alveolar Epithelial Permeability

    International Nuclear Information System (INIS)

    Vaskova, Olivija

    1996-01-01

    normals reported by many authors. Standardizing the procedures and establishing the normal range we started to use already proven method in different groups of subjects exposed to harmful agents supposed that alter epithelial integrity. Increased lung clearance of inhaled aerosols were obtained in non-symptomatic smokers, asbestosis suffering patients, and in non-smokers exposed to asbestos with normal lung ventilation studies. Faster clearance was also found in the patients with chronic renal failure on regular haemodialysis program using bio incompatible membrane, longer than 5 years. At the same time normal values were obtained in the group on short term haemodialysis. Abnormal clearance rate was shown in patients with malignant disease, exposed to external and internal lung radiation, and in subjects on long term amiodarone treatment, as well. In patients with cardiac heart failure and lung edema, and first stage of sarcoidosis, lung clearance was normal. It remains now as further challenge comparison of there values with some other investigations, expectantly it would contribute in elucidation of different mechanisms in pulmonary pathology. Assessment of 99m Tc-DTPA lung clearance is a very attractive method, non-invasive, cheap, and widely available. Until now there is no an other alternative procedure that would be able to give us more information about epithelial permeability. (Author)

  17. Influence of posture and positive end-tidal expiratory pressure (PEEP) on clearance of Tc99m-DTPA from the lungs

    International Nuclear Information System (INIS)

    Mason, G.R.; Maublant, J.; Sietsema, K.; Effros, R.M.; Mena, I.

    1984-01-01

    The clearance of Tc99m-DTPA aerosols from the lung has been used to detect and quantitate alterations in the permeability of the pulmonary epithelium. Clearance of the radionuclide is accelerated by both chronic and acute injuries to the lung and by smoking. Several laboratories have reported that Tc99m-DTPA clearance from upper lobes exceeded that from lower lobes in upright subjects. To investigate this phenomenon further the authors studied subjects with simultaneous anterior and posterior cameras in upright and supine positions. In the upright position, clearance from both the anterior and posterior upper regions of interest (ROI's) exceeded the lower regions (-1.64 +- .42 S.D. vs. -0.75 +- .41, anterior, p < .05, n=6), -1.04 +- .23 vs. -0.50 +- .36, posterior. All units = %/min. This difference was not observed in the supine subjects. Clearance from the anterior chest exceeded that from the posterior chest in the supine subjects (-1.28 +- .45 vs. -0.05 +- 1.08) and a small increase in radio-activity was observed in at least one ROI of 5 of 6 subjects from the posterior camera. An increase in activity is likely to be secondary to labeling of blood pool, which would have greatest affect where pulmonary blood volume is largest. Computer processing of the entire lung without observer bias in ROI placement showed similar effects of posture over non-peripheral ROI's. Five subjects breathed on PEEP to cause airspace distention, causing clearance to double. Both dependency and airspace distention appear to influence clearance of aerosolized DTPA, the latter may occur by stretching of epithelial pores

  18. Estimation in adults of the glomerular filtration rate in [99mTc] DTPA renography - the rate constant method

    International Nuclear Information System (INIS)

    Carlsen, Ove

    2004-01-01

    The purpose of this study was to design an alternative and robust method for estimation of glomerular filtration rate (GFR) in [ 99 mTc]-diethylenetriaminepentaacetic acid ([ 99 mTc] -DTPA renography with a reliability not significantly lower than that of the conventional Gates' method. Methods: The method is based on renographies lasting 40 min in which regions of interest (ROIs) are manually created over selected parts of certain blood pools (e.g. heart, lungs, spleen, and liver). For each ROI the corresponding time-activity curve (TAC) was generated, decay corrected and exposed to a monoexponential fit in the time interval 10 to 40 min postinjection. The rate constant in min-1 of the monoexponential fit was denoted BETA. Following an iterative procedure comprising usually 5-10 manually created ROIs, the monoexponential fit with the maximum rate constant (BETA max ) was used for estimation of GFR. Results: In a patient material of 54 adult subjects in whom GFR was determined with multiple or one sample techniques with [ 51 Cr]-ethylenediaminetetraacetic acid ([ 51 Cr]-EDTA) the regression curve of standard GFR (GFR std ) (i.e. GFR adjusted to 1.73 m 2 body surface area) showed a close, non-linear relationship with BETA max with a correlation coefficient of 95%. The standard errors of estimate (SEE) were 6.6, 10.6 and 16.8 for GFR std equal to 30, 60, and 120 ml/(min .73 m 2 ), respectively. The corresponding SEE values for almost the same patient material using Gates' method were 8.4, 11.9, and 16.8 ml/(min 1.73 m 2 ). Conclusions: The alternative rate constant method yields estimates of GFR std with SEE values equal to or slightly smaller than in Gates' method. The two methods provide statistically uncorrelated estimates of GFR std . Therefore, pooled estimates of GFR std can be calculated with SEE values approximately 1.41 times smaller than those mentioned above. The reliabilities of the pooled estimate of GFR std separately and of the multiple samples method

  19. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  20. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    Science.gov (United States)

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  1. Reliability of single kidney glomerular filtration rate measured by a 99mTc-DTPA gamma camera technique

    International Nuclear Information System (INIS)

    Rehling, M.; Moller, M.L.; Jensen, J.J.; Thamdrup, B.; Lund, J.O.; Trap-Jensen, J.

    1986-01-01

    The reliability of a previously published method for determination of single kidney glomerular filtration rate (SKGFR) by means of technetium-99m-diethylenetriaminepenta-acetate (99mTc-DTPA) gamma camera renography was evaluated. The day-to-day variation in the calculated SKGFR values was earlier found to be 8.8%. The technique was compared to the simultaneously measured renal clearance of inulin in 19 unilaterally nephrectomized patients with GFR varying from 11 to 76 ml/min. The regression line (y = 1.04 X -2.5) did not differ significantly from the line of identity. The standard error of estimate was 4.3 ml/min. In 17 patients the inter- and intraobserver variation of the calculated SKGFR values was 1.2 ml/min and 1.3 ml/min, respectively. In 21 of 25 healthy subjects studied (age range 27-29 years), total GFR calculated from the renograms was within an established age-dependent normal range of GFR

  2. Impact of Gate 99mTc DTPA GFR, Serum Creatinine and Urea in Diagnosis of Patients with Chronic Kidney Failure

    OpenAIRE

    Miftari, Rame; Nura, Adem; Top?iu-Shufta, Valdete; Miftari, Valon; Murseli, Arbenita; Haxhibeqiri, Valdete

    2017-01-01

    Aim: The aim of this study was determination of validity of 99mTcDTPA estimation of GFR for early detection of chronic kidney failure Material and methods: There were 110 patients (54 males and 56 females) with kidney disease referred for evaluation of renal function at UCC of Kosovo. All patients were included in two groups. In the first group were included 30 patients confirmed with renal failure, whereas in the second group were included 80 patients with other renal disease. In study were ...

  3. Quality control of 99mTc-DTPA-octreotide by reverse high performance liquid chromatography

    International Nuclear Information System (INIS)

    Cheng, Z.; Lin, Q.F.; Jin, X.H.; Wang, F.; Bai, H.S.; Chen, D.M.; Fan, H.Q.; Du, J.

    1998-01-01

    DTPA-Octreotide(Pentetreotide), a somatostatin analogue which can bind specifically and with high affinity to somatostatin receptor in vitro and vivo, labeled with 99m Tc by tin reduction in acetate buffer, has been characterized by Reverse-phase High performance Liquid Chromatography. The effect of different solvents, mobile phase pH, linear gradient and the injected volume on the separation efficiency was evaluated. The results show that the separation efficiency is best using μBondapak-C 18 (300x3.9 mm 2 ), linear gradient of 40% to 80% methanol (1.0 ml/min) in 0.05M acetate buffer (pH 5.5) over a 30 min period and maintaining for another 10 min. The labeled product is a mixture which mainly consists of five components (a, b, c, d, e) successfully proved by HPLC. Paper chromatography is also evaluated in this paper. It may be used to determine the radiochemical purity of the labeling product, but is not a good choice for the verification each components. (author)

  4. Comparative microvascular exchange kinetics of [{sup 77}Br]bromide and {sup 99m}Tc-DTPA in humans

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, Claire [Department of Clinical Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom); Skehan, Stephen J.; Rolph, Susan M.; Flaxman, Mary E.; Ballinger, James R.; Bird, Nicholas J.; Barber, Robert W.; Peters, Michael A. [Department of Nuclear Medicine, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2002-05-01

    The plasma clearance curves of small hydrophilic solutes comprise three exponentials, consistent with a three-compartmental distribution model. A previous comparison between inulin and diethylene triamine penta-acetic acid (DTPA) suggested that these three compartments are in series, the first being plasma and the second and third representing compartments within the extravascular space. Moreover, whilst the total distribution volumes of these two indicators were similar, the volume of the second compartment was higher for DTPA. The purpose of the current study was to investigate whether a solute smaller than DTPA, namely bromide, fits the hypothesis that the second space volume is an inverse function of the size of the solute. Two groups of subjects were studied: group A comprised eight patients undergoing routine diagnostic arteriography and group B, eight patients referred for routine measurement of glomerular filtration rate plus two normal volunteers. {sup 99m}Tc-DTPA and sodium [{sup 77}Br]bromide were intravenously administered simultaneously. In group A, frequent arterial samples were obtained up to 40 min after injection, and antecubital venous samples 30 s after each arterial sample. In group B, frequent venous samples were obtained up to 280 min after injection. Volume measurements based on bromide were corrected for erythrocyte bromide accumulation. In both subject groups, the normalised venous concentration ratio of bromide to DTPA, corrected for red cell bromide uptake, was significantly less than unity in the earliest blood samples, being 0.56 (SD 0.08) at 1 min, consistent with faster diffusion of bromide from plasma to interstitial fluid. Furthermore, the extraction fraction of bromide from plasma to interstitial fluid in the forearm was about 0.6, higher than that of DTPA (about 0.5) in spite of red cell bromide accumulation which equilibrated with plasma bromide within 20 s and resulted in a red cell to plasma concentration ratio of 0.51 (0

  5. Clinical usefulness of physiological components obtained by factor analysis. Application to /sup 99m/Tc-DTPA renography

    Energy Technology Data Exchange (ETDEWEB)

    Ohtake, Eiji; Murata, Hajime; Matsuda, Hirofumi; Yokoyama, Masao; Toyama, Hinako; Satoh, Tomohiko.

    1989-01-01

    The clinical usefulness of physiological components obtained by factor analysis was assessed in /sup 99m/Tc-DTPA renography. Using definite physiological components, another dynamic data could be analyzed. In this paper, the dynamic renal function after ESWL (Extracorporeal Shock Wave Lithotripsy) treatment was examined using physiological components in the kidney before ESWL and/or a normal kidney. We could easily evaluate the change of renal functions by this method. The usefulness of a new analysis using physiological components was summarized as follows: (1) The change of a dynamic function could be assessed in quantity as that of the contribution ratio. (2) The change of a sick condition could be morphologically evaluated as that of the functional image.

  6. Assessment of hepatic functional reserve for hepatic resection using 99mTc-PMT scintigraphy in comparison with 99mTc-GSA scintigraphy

    International Nuclear Information System (INIS)

    Sakuma, Atsushi

    2000-01-01

    99m Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin( 99m Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed 99m Tc-N-pyridoxyl-5-methyl-tryptophan( 99m Tc-PMT) and 99m Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent 99m Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. 99m Tc-GSA scintigraphy was also performed within two weeks of the 99m Tc-PMT scintigraphy, and the ratio of disappearance (HH 15 ) and the hepatic uptake ratio (LHL 15 ) were computed. The relationship between K value, HBF, PVR, HH 15 and LHL 15 was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH 15 and LHL 15 , PVR correlated statistically significantly HH 15 and LHL 15 . K value correlated with the preoperative values of cholinesterase, Fischer ratio, γ-globulin, ICGR 15 , albumin, and platelet count. There was a statistically significant correlation between LHL 15 and the value of cholinesterase, γ-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL 15 value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that 99m Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and 99m Tc-PMT scintigraphy reflect the hepatic blood flow and ability of protein synthesis. It was proved that 99m Tc-PMT scintigraphy is

  7. Targeting osteomyelitis with complete [99mTc]besilesomab and fragmented [99mTc]sulesomab antibodies: kinetic evaluations

    International Nuclear Information System (INIS)

    GRATZ, Stefan; KEMKE, Bendix; KEIZE, Patrik; KAMPEN, Wim U.; LUSTER, Markus; HÖFFKEN, Helmut

    2016-01-01

    The aim of this retrospective study was to compare the targeting of “pure” osteomyelitis (i.e., without surrounding soft tissue infection) by directly 99mTc-labelled complete immunoglobulin G (IgG) monoclonal antibody (MAb) ([99mTc]besilesomab) and by directly 99mTc-labelled fragment antigen-binding (FAb) MAb ([99mTc]sulesomab) in relation to their kinetic fate. A total of 73 patients with “pure” osteomyelitis were examined with [99mTc]besilesomab, (Scintimun®, IBA/CIS bio international, Saclay, France; N.=38) and [99mTc]sulesomab (LeukoScan®, Immunomedics Inc., Morris Plains, NJ, USA; N.=35). Kinetic data were deduced from whole-body and single-photon emission computed tomographic scans, performed 10 minutes to 24 hour p.i. (region-of-interest technique [ROI]). In targeting “pure” osteomyelitis, sensitivities at 1-4 hours were found to be higher for [99mTc]sulesomab (44% and 80% for [99mTc]besilesomab and [99mTc]sulesomab, respectively) but at significantly lower target/background (T/B) ratios than with [99mTc]besilesomab (1.8±0.3 versus 1.4±0.5 for [99mTc]besilesomab and [99mTc]sulesomab respectively; P<0.01). With [99mTc]besilesomab, there was a continuous osteomyelitis uptake over 24 hours, whereas with [99mTc]sulesomab, the maximal uptake occurred mostly within 1-4 hours, with subsequent clearance being slower for antigen-bound activity than for nonspecific background. Hence, diagnosis was possible mostly after 4h with [99mTc]sulesomab but often not before 24 hours with [99mTc]besilesomab, the later increasing significantly (P<0.01) in sensitivity (87% and 84% for [99mTc]besilesomab and [99mTc]sulesomab, respectively). These results show that the higher sensitivity of [99mTc]sulesomab in osteomyelitis targeting at earlier p.i. times does not rely on an increased antibody uptake but on a more rapid clearance of nonspecific background activity due to faster metabolism and excretion. Intact [99mTc]besilesomab show a slow, continuous uptake

  8. Quality control of technetium-99m DTPA: correlation of analytic tests with in vivo protein binding in man

    International Nuclear Information System (INIS)

    Russell, C.D.; Rowell, K.; Scott, J.W.

    1986-01-01

    When [/sup 99m/Tc]DTPA is administered, a small fraction of the activity (presumably an impurity) is bound to plasma proteins. This causes an error in the calculation of glomerular filtration rate from plasma clearance. This paper presents two methods of laboratory quality control for measuring the fraction that binds to plasma proteins. One method involves in vitro binding to human serum albumin followed by gel filtration. The other method involves descending paper chromatography on wet pre-equilibrated anion exchange paper. In a series of 80 patients, correlation was demonstrated between laboratory characteristics and actual clinical performance of the [/sup 99m/Tc]DTPA preparation. Both laboratory methods appear suitable for routine quality control

  9. Contribution of 99mTc-DTPA dynamic renal scintigraphy with furosemide test in the exploration of low grade urethra-pelvic junction syndrome. Report of 17 cases

    International Nuclear Information System (INIS)

    Ghfir, I.; Ben Rais, N.

    2009-01-01

    Introduction The renal scintigraphy using 99m Tc-DTPA with furosemide test constitutes a noninvasive and functional method that is of appreciable interest in the exploration of the upper urinary tract and in the evaluation of the separate renal function. It distinguishes the functional character of dilation from organic obstruction needing surgery or endoscopic treatment. Material and methods We report, through this work, the observations of 17 patients with a low grade urethra-pelvic junction syndrome detect by intravenous urography (I.V.U.). 99m Tc-DTPA renal scintigraphy with furosemide test was carried out among all our patients by means of a gamma-camera with large field equipped with a low energy high-resolution parallel collimator. The evaluation of images obtained consisted of analysis of urethra-pelvic permeability taking into account the semiquantitative parameters of time-activity curve or isotopic nephrogram (I.N.) obtained after digital reconstruction of sequential images. Results On the 17 studied cases, the sex-ratio was equal to 1.83; the average age was 18.92 years with extremes spanning from 4 years to 70 years. Renal scintigraphy categorized four patients groups. Group I: two patients (11.76%) with normal aspect of I.N.; group II; seven patients (41.17% of cases) with functional dilation; group III: five patients (29.41%) with organic obstruction and a group IV: three patients (17.64%) with intermediate response. Discussion 99m Tc-DTPA renal scintigraphy with furosemide test allowed, through our study, to obviate the limits of IVU and manometric explorations to distinguish functional dilation of organic obstruction. It permits the improvement of treatment with a favourable dosimetry. (authors)

  10. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  11. Direct 99mTc labeling of monoclonal antibodies: radiolabeling and in vitro stability

    International Nuclear Information System (INIS)

    Garron, J.Y.; Moinereau, M.; Pasqualini, R.; Saccavini, J.C.

    1991-01-01

    Direct labeling involves 99m Tc binding to different donor groups on the protein, giving multiple binding sites of various affinities resulting in an in vivo instability. The stability has been considerably improved by activating the antibody using a controlled reduction reaction (using 2-aminoethanethiol). This reaction generates sulfhydryl groups, which are known to strongly bind 99m Tc. The direct 99m Tc antibody labeling method was explored using whole antibodies and fragments. Analytical methods were developed for routine evaluation of radiolabeling yield and in vitro stability. Stable direct antibody labeling with 99m Tc requires the generation of sulfhydryl groups, which show high affinity binding sites for 99m Tc. Such groups are obtained with 2-aminoethanethiol (AET), which induces the reduction of the intrachain or interchain disulfide bond, with no structural deterioration or any loss of immunobiological activity of the antibody. The development of fast, reliable analytical methods has made possible the qualitative and quantitative assessment of technetium species generated by the radiolabeling process. Labeling stability is determined by competition of the 99m Tc-antibody bond with three ligands, Chelex 100 (a metal chelate-type resin), free DTPA solution and 1% HSA solution. Very good 99m Tc-antibody stability is obtained with activated IgG (IgGa) and Fab' fragment, which makes these substances possible candidates for immunoscintigraphy use. (author)

  12. Tc-99m-DTPA renal scintigraphy and detection of intrarenal reflux

    International Nuclear Information System (INIS)

    Poropat, M.; Basic, M.; Dodig, D.; Batinic, D.; Nizic, Lj.

    1994-01-01

    The intrarenal reflux plays the key role in the etiology of reflux nephropathy and its detection is of utmost importance in evaluating possible damage in kidney with reflux. In 176 kidneys (113 children) with different degree of vesicoureteric reflux (VUR), dynamic renal scintigraphy with Tc-99m-DTPA in zoom mode was performed. From each study 6 functional images of mean time were generated, kidney contour superimposed on each, and time activity curves (TAC) over possible areas of increased mean time were generated. In these study we analyzed only areas of increased mean time over the outer contour of the kidney which corresponds to the renal parenchyma. In later functional images of the mean time we found 53 focal retentions over the part of the kidney which corresponds to the renal cortex (33 in upper, 5 in middle and 15 in lower part of the kidney). TAC-s generated over these areas exhibited a sharp increase of activity on the descending part of the curves. We propose that the return of activity from the collecting system to the kidney cortex represents intrarenal reflux. In our opinion, analysis of functional images of the mean time could be a method for more accurate detection of intrarenal reflux and indicating the children with high risk to acquire renal scarring. (author)

  13. Synthesis and comparison of 99mTc-enrofloxacin and 99mTc-ciprofloxacin.

    NARCIS (Netherlands)

    Siaens, R.H.; Rennen, H.J.J.M.; Boerman, O.C.; Dierckx, R.A.; Slegers, G.

    2004-01-01

    The use of (99m)Tc-ciprofloxacin as a tracer for infection and inflammation has been examined and discussed in the literature extensively. Its alleged ability to discriminate between sterile inflammation and bacterial versus nonbacterial infections has led to an intense debate. Other labeled

  14. Preparation and biological profile of 99mTc-lidocaine as a cardioselective imaging agent using 99mTc eluted from 99Mo/99mTc generator based on Al-Mo gel

    International Nuclear Information System (INIS)

    Sakr, T.M.; October University of Modern Sciences and Arts; Ibrahim, A.B.; Rashed, H.M.; Fasih, T.W.

    2017-01-01

    The current study is aimed to prepare 99m Tc-lidocaine as a new myocardial perfusion-imaging agent. The used 99m Tc was obtained from Al- 99 Mo-molybdate(VI) gel matrix. 99m Tc-lidocaine showed higher (15.4 ± 0.11% ID/g) and faster (15 min post injection) cardiac uptake than the recently studied 99m Tc-valsartan and 99m Tc-procainamide. Consequently, 99m Tc-lidocaine will be a valuable myocardial SPECT agent for diagnosis of emergency patients. Besides, the receptor affinity study confirmed the selectivity of 99m Tc-lidocaine for sodium channels in the heart. (author)

  15. An intrapatient comparison of 99mTc-EDDA/HYNIC-TOC with 111In-DTPA-octreotide for diagnosis of somatostatin receptor-expressing tumors.

    Science.gov (United States)

    Gabriel, Michael; Decristoforo, Clemens; Donnemiller, Eveline; Ulmer, Hanno; Watfah Rychlinski, Christine; Mather, Stephen J; Moncayo, Roy

    2003-05-01

    The aim of this study was to compare the imaging abilities of the recently developed somatostatin analog, (99m)Tc-hydrazinonicotinyl-Tyr(3)-octreotide ((99m)Tc-HYNIC-TOC [(99m)Tc-TOC]), with (111)In-diethylenediaminepentaacetic acid-D-Phe(1)-octreotide ((111)In-OCT [Octreoscan]) in patients undergoing routine somatostatin receptor (SSTR) scintigraphy. Forty-one patients (20 men, 21 women; age range, 29-75 y; mean age, 56.7 y) with either histologically proven or biologically and clinically suspected endocrine tumors were enrolled in the study. Four groups were distinguished: (a) patients being evaluated for the detection and localization of neuroendocrine tumors (n = 6), (b) tumor staging (n = 19), (c) patients being investigated to determine the SSTR status of tumor lesions (n = 11), and (d) patient follow-up studies (n = 5). Each patient received a mean activity of 150 MBq (111)In-OCT and 350-400 MBq (99m)Tc-TOC. Scintigraphy with (99m)Tc-TOC was performed 4 h after injection and scintigraphy with (111)In-OCT was performed 4 and 24 h after injection. SPECT studies of areas of interest were performed 4 h after injection for both tracers as well as at 24 h after injection for (111)In-OCT. The time interval between the studies using each tracer ranged from 2 to 22 d (mean interval, 9.3 d). (111)In-OCT and (99m)Tc-TOC showed an equivalent scan result in 32 patients (78%), 9 cases showed discrepancies (22%), false-negative results with (111)In-OCT were seen in 6 cases (14.6%), whereas (99m)Tc-TOC was false-positive in 2 cases (4.9%). (111)In-OCT was true-negative in both cases. The false-positive findings of the (99m)Tc-TOC studies were caused by nonspecific uptake in the bowel. In 1 case, (99m)Tc-TOC correctly identified a metastasis in the lumbar spine but both scan results were false-positive because of an inflammatory process. In 21 patients with SSTR-expressing tumors, the semiquantitative region-of-interest analysis showed that (99m)Tc-TOC achieved higher tumor

  16. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  17. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    Science.gov (United States)

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  19. Use of 99mTc from a commercial 99Mo/9mTc generator as yield tracer for the determination of 99Tc at low levels

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Jensen, Mikael; Nielsen, Sven Poul

    2007-01-01

    The concentrations of Tc-99 and impurity radionuclides in the Tc-99m tracer solution obtained from a commercial Mo-99/Tc-99m generator were measured by gamma spectrometry and liquid scintillation counting. Mo-99 and Ru-103 were found in the Tc-99m eluate. A simple separation using two extra alumina...... cartridges was investigated to purify the eluate to obtain a suitable Tc-99m tracer with low Tc-99 concentration. The activity ratio of Tc-99/Tc-99m in the prepared Tc-99m solution is lower than 15 x 10(-9), which is higher than the theoretical ratio of less than 10 x 10(-9). The possible reason is discussed....... The Tc-99 in the 20 kBq spiked Tc-99m tracer was found to be less than 0.3mBq, which is lower than the detection limit of the radiometric method used for environmental samples. The purified Tc-99m eluate is used as yield tracer for the determination of low levels of Tc-99 in environmental samples. (c...

  20. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    Science.gov (United States)

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  1. Hot spots on Tc-99m MAA perfusion lung scan

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee

    2001-01-01

    A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings. A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities. Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear borders. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan

  2. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  3. Evaluation of sup(99m)Tc-albumin dilution curve with simultaneous injection of sup(99m)Tc- and 131I-albumins

    International Nuclear Information System (INIS)

    Kinoshita, Masahiko; Kato, Shotaro; Motomura, Masakazu; Kawakita, Seiichi

    1979-01-01

    A critical comparison of radiocardiograms with sup(99m)Tc- and 131 I-albumins was made to determine whether or not sup(99m)Te-albumin can be used as a tracer for measuring blood volume (BV) and cardiac output (CO). Simultaneous injection of both isotopes was given to twenty-two patients to obtain radiocardiograms for each by means of a single scintillation counter with two pulse height analyzers. Such method allows for the determination of the energy levels for both sup(99m)Tc and 131 I. The radiocardiographic pattern was somewhat different between sup(99m)Tc- and 131 I-radiocardiograms: The ratio of left to right peak height was 16% on the average lower in the sup(99m)Tc-radiocardiogram than in the 131 I-one. The reason for the lower ratio is explained by greater absorption of sup(99m)Tc-radioactivity within the soft tissue interposing between the scintillation probe and heart. The values for sup(99m)Tc-derived blood volume were 7.4% on the average larger than those for 131 I-derived blood volume (p less than 0.01), although the correlation was excellent (r = 0.98 p less than 0.01). There was no systemic difference between cardiac output determined by sup(99m)Tc- and 131 I-albumins since the overestimation of blood volume can compensate for the underestimation of CO/BV by sup(99m)Tc-study. In view of its rapid extravasation, sup(99m)Tc-albumin is not so appropriate tracer for accurate measurements of BV and CO/BV, although it may be used for measurement of cardiac output. (author)

  4. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma.

    Science.gov (United States)

    Czepczyński, Rafał; Parisella, Maria Gemma; Kosowicz, Jerzy; Mikołajczak, Renata; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy; Signore, Alberto

    2007-10-01

    Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin analogue (99m)Tc-EDDA/HYNIC-TOC in MTC in comparison with other diagnostic techniques. Forty-five patients with MTC, aged 14-83 years, were investigated. Scintigraphy using (99m)Tc-EDDA/HYNIC-TOC (Tektrotyd) was performed 2 and 4 h post injection of 740 MBq (20 mCi) of the tracer. Other imaging techniques were also applied and analysed in individual cases (ultrasonography, computed tomography, (99m)Tc(V)-DMSA, (131)I-MIBG, (99m)Tc-MDP, (111)In-DTPA-octreotide and (18)F-FDG-PET) and compared with (99m)Tc-EDDA/HYNIC-TOC. In group 1 (eight patients before thyroidectomy), uptake of the tracer was found in the primary tumours. In group 2 (six patients with remission), a false positive result was found in one patient; in the remaining five patients, no pathological foci were visualised. In group 3 (31 patients with post-surgical hypercalcitoninaemia), scintigraphy was true positive in 23 patients (74.2%): uptake in the thyroid bed was found in five patients, in the lymph nodes in 18 and in bone metastases in four. Using (99m)Tc-EDDA/HYNIC-TOC scintigraphy, the overall sensitivity was 79.5%, specificity 83.3%, accuracy 80.0%, positive predictive value 96.9% and negative predictive value 38.5%. (99m)Tc-EDDA/HYNIC-TOC is clinically useful for scintigraphy in the follow-up of patients with MTC. It can be used in clinical practice for preoperative evaluation, for localisation of local recurrence or distant metastases and particularly for therapy decision making.

  5. Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC in patients with medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Czepczynski, Rafal; Kosowicz, Jerzy; Ziemnicka, Katarzyna; Gryczynska, Maria; Sowinski, Jerzy; Parisella, Maria G.; Mikolajczak, Renata; Signore, Alberto

    2007-01-01

    Several new somatostatin analogues have been developed for the diagnosis and therapy of different tumours. Since somatostatin receptors are often over-expressed in medullary thyroid carcinoma (MTC), the aim of our study was to evaluate the utility of scintigraphy with the somatostatin analogue 99m Tc-EDDA/HYNIC-TOC in MTC in comparison with other diagnostic techniques. Forty-five patients with MTC, aged 14-83 years, were investigated. Scintigraphy using 99m Tc-EDDA/HYNIC-TOC (Tektrotyd) was performed 2 and 4 h post injection of 740 MBq (20 mCi) of the tracer. Other imaging techniques were also applied and analysed in individual cases (ultrasonography, computed tomography, 99m Tc(V)-DMSA, 131 I-MIBG, 99m Tc-MDP, 111 In-DTPA-octreotide and 18 F-FDG-PET) and compared with 99m Tc-EDDA/HYNIC-TOC. In group 1 (eight patients before thyroidectomy), uptake of the tracer was found in the primary tumours. In group 2 (six patients with remission), a false positive result was found in one patient; in the remaining five patients, no pathological foci were visualised. In group 3 (31 patients with post-surgical hypercalcitoninaemia), scintigraphy was true positive in 23 patients (74.2%): uptake in the thyroid bed was found in five patients, in the lymph nodes in 18 and in bone metastases in four. Using 99m Tc-EDDA/HYNIC-TOC scintigraphy, the overall sensitivity was 79.5%, specificity 83.3%, accuracy 80.0%, positive predictive value 96.9% and negative predictive value 38.5%. 99m Tc-EDDA/HYNIC-TOC is clinically useful for scintigraphy in the follow-up of patients with MTC. It can be used in clinical practice for preoperative evaluation, for localisation of local recurrence or distant metastases and particularly for therapy decision making. (orig.)

  6. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  7. Sequential hepatobiliary scintigraphy of the patients with constitutional jaundice, ICG excretory defect disease and hepatocellular carcinoma with 99mTc-PI, 99mTc-HIDA and 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Mitani, Tsuyoshi

    1987-01-01

    Sequential 2 min scintiphotos were obtained with a scintilation camera after intravenous injection of 3 mCi of 99m Tc-HIDA or 99m Tc-PI. Digital matrix images were simultaneously recorded with computer. Sequential samples for the blood clearance of 99m Tc-HIDA or 99m Tc-PI were obtained for 120 min following injection to the patient of constitutional hyperbilirubinemia and ICG excretory defect disease. In Dubin-Johnson syndrome, the hepatic uptake of 99m Tc-HIDA was faster or normal but the excretion was extremely slower than in normal cases. Both hepatic uptake and excretion of 99m Tc-PI were almost normal. In Rotor's disease, hepatic uptake of 99m Tc-HIDA or 99m Tc-PI was very poor, showing almost no hepatic images in all time. In Gilbert's disease and ICG excretory defect disease, hepatic uptake and excretion of 99m Tc-HIDA or 99m Tc-PI were within normal limit. From these results, Dubin-Johnson syndrome, Rotor's disease and Gilbert's disease show the different patterns between hepatic uptake and excretion of 99m Tc-HIDA and 99m Tc-PI hepatobiliary scintigraphy and these patterns contribute to the differential diagnosis of constitutional jaundice. The usefulness of hepatobiliary imaging with 99m Tc-EHIDA in diagnosis of hepatocellular carcinoma was studied in 15 patients with histologically verified HCC. In 15 patients, 3 patients (20 %) showed increased radioactivity with 99m Tc-EHIDA image, where liver scan with 99m Tc-Sn colloid showed filling defect. These results indicate that use of 99m Tc-EHIDA scan and 67 Ga-citrate imaging is useful for positive visualization of HCC. (author)

  8. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    Science.gov (United States)

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  9. Contribution of {sup 99m}Tc-DTPA dynamic renal scintigraphy with furosemide test in the exploration of low grade urethra-pelvic junction syndrome. Report of 17 cases; Apport de la scintigraphie renale dynamique au {sup 99m}Tc-DTPA avec epreuve au furosemide dans l'exploration du syndrome de la jonction pyelo-uretrale a minima. A propos de 17 cas

    Energy Technology Data Exchange (ETDEWEB)

    Ghfir, I.; Ben Rais, N. [Hopital Ibn Sina, CHU de Rabat, Service de Medecine Nucleaire, Rabat (Morocco)

    2009-10-15

    Introduction The renal scintigraphy using {sup 99m}Tc-DTPA with furosemide test constitutes a noninvasive and functional method that is of appreciable interest in the exploration of the upper urinary tract and in the evaluation of the separate renal function. It distinguishes the functional character of dilation from organic obstruction needing surgery or endoscopic treatment. Material and methods We report, through this work, the observations of 17 patients with a low grade urethra-pelvic junction syndrome detect by intravenous urography (I.V.U.). {sup 99m}Tc-DTPA renal scintigraphy with furosemide test was carried out among all our patients by means of a gamma-camera with large field equipped with a low energy high-resolution parallel collimator. The evaluation of images obtained consisted of analysis of urethra-pelvic permeability taking into account the semiquantitative parameters of time-activity curve or isotopic nephrogram (I.N.) obtained after digital reconstruction of sequential images. Results On the 17 studied cases, the sex-ratio was equal to 1.83; the average age was 18.92 years with extremes spanning from 4 years to 70 years. Renal scintigraphy categorized four patients groups. Group I: two patients (11.76%) with normal aspect of I.N.; group II; seven patients (41.17% of cases) with functional dilation; group III: five patients (29.41%) with organic obstruction and a group IV: three patients (17.64%) with intermediate response. Discussion {sup 99m}Tc-DTPA renal scintigraphy with furosemide test allowed, through our study, to obviate the limits of IVU and manometric explorations to distinguish functional dilation of organic obstruction. It permits the improvement of treatment with a favourable dosimetry. (authors)

  10. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Aim: To investigate in-vitro the uptake and washout of Tc-99m-MIBI and Tc-99m-tetrofosmin in human breast adenocarcinoma and soft tissue sarcoma cell lines. Methods: The uptake of Tc-99m-MIBI and Tc-99m-tetrofosmin (at 37 0 C, 10, 30 and 60 minutes after incubation with 7.4x10E5 Bq each tracer) was investigated in breast adenocarcinoma MCF-7 and SK-BR-3 cells, synovial sarcoma SW 982 cells and chondrosarcoma SW 1353 cells (concentration of 1x10E6 cells/ml incubation medium). Tracer uptake in cells incubated with ouabain (Na/K-ATPase pump inhibitor; 100 μM and 1mM; 15 and 30 minutes), nigericin (increases mitochondrial potential and disrupts cell membrane potential; 5 and 50 μg/ml; 15 minutes) and carbonyl cyanide m-chlorophenylhydrazone (CCCP) (depolarizes mitochondrial membrane; 10 and 100 μM; 30 minutes) was compared to that in cells without incubation with chemical agents (control cells). The washout (at 37 0 C, 10-60 minutes, 30 and 60 minutes after tracer incubation) of Tc-99m-MIBI and Tc-99m-tetrofosmin was studied in MCF-7 cells, SK-BR-3 cells , SW 1353 cells and fibrosarcoma SW 684 cells. Results: Cellular tracer uptake decreased with ouabain (decrease of Tc-99m-tetrofosmin > Tc-99m-MIBI in SK-BR-3 cells and SW 982 cells) and increased with nigericin (increase of Tc-99m-MIBI > Tc-99m-tetrofosmin in all cells) as compared to the uptake in control cells. With CCCP, decrease of Tc-99m-MIBI uptake in cells preincubated with nigericin was higher than that in cells under basal conditions, whereas a similar decrease of Tc-99m-tetrofosmin uptake in these two group of cells was found. Washout of Tc-99m-MIBI from all cells was lower than that of Tc-99m-tetrofosmin. No significant difference in cell-associated activity of both tracers was found between washout after 30 minutes and that after 60 minutes of incubation, in all cells. Washout of Tc-99m-MIBI from SK-BR-3 cells Tc-99m-tetrofosmin) and Na/K-ATPase pump (Tc-99m-tetrofosmin > Tc-99m-MIBI). Tc-99m-MIBI and

  11. Tc-99m-hexakis(t-butylisonitrile)-technetium(I) (Tc-99m-TBI)

    International Nuclear Information System (INIS)

    Angelberger, P.; Dudczak, R.; Jones, A.G.; Lister-James, J.; Wagner-Loffler, M.; Buchheit, O.; Fally, F.

    1986-01-01

    The potassium analog (Tl-201)/sup +/ is widely used in nuclear cardiology but has inferior scintigraphic (80 keV photons), dosimetric and economic properties as compared to Tc-99m. Therefore considerable efforts have been made to develop a Tc-compound that would accumulate in the myocardium in relation to regional blood flow. This study was aimed at optimizing the preparation of Tc-TBI with n.c.a. Tc-99m, analyze and purify the product with HPLC, verify biodistribution in mice and undertake a clinical evaluation

  12. Radionuclide imaging of small-cell lung cancer (SCLC) using 99mTc-labeled neurotensin peptide 8-13

    International Nuclear Information System (INIS)

    Zhang Kaijun; An Rui; Gao Zairong; Zhang Yongxue; Aruva, Mohan R.

    2006-01-01

    Objectives: To prepare 99m technetium ( 99m Tc)-labeled neurotensin (NT) peptide and to evaluate the feasibility of imaging oncogene NT receptors overexpressed in human small-cell lung cancer (SCLC) cells. Methods: The NT analogue (Nα-His)Ac-NT(8-13) was synthesized such that histidine was attached at the N-terminus. The analogue was labeled with [ 99m Tc(H 2 O) 3 (CO) 3 ] at pH 7. 99m Tc-(Nα-His)Ac-NT(8-13) in vitro stability was determined by challenging it with 100 times the molar excess of DTPA, human serum albumin (HSA) and cysteine. The affinity, 99m Tc-(Nα-His)Ac-NT(8-13) binding to SCLC cell line NCI-H446, was studied in vitro. Biodistribution and imaging with 99m Tc-(Nα-His)Ac-NT(8-13) were performed at 4 and 12 h postinjection, and tissue distribution and imaging after receptor blocking were carried out at 4 h in nude mice bearing human SCLC tumor. Blood clearance was determined in normal mice. Results: The affinity constant (K d ) of 99m Tc-(Nα-His)Ac-NT(8-13) to SCLC cells was 0.56 nmol/L. When challenged with 100 times the molar excess of DTPA, HSA or cysteine, more than 97±1.8% radioactivity remained as 99m Tc-(Nα-His)Ac-NT(8-13). Tumor-to-muscle ratio was 3.35±1.01 at 4 h and 4.20±1.35 at 12 h postinjection. The excretory route of 99m Tc-(Nα-His)Ac-NT(8-13) was chiefly through the renal pathway. In the receptor-blocking group treated with unlabeled (Nα-His)Ac-NT(8-13), tumor-to-muscle ratio at 4 h was 1.25±0.55. Conclusion: The results suggest that 99m Tc-(Nα-His)Ac-NT(8-13) specifically binds to the SCLC cells and made 99m Tc-(Nα-His)Ac-NT(8-13) a desirable compound for further studies in planar or SPECT imaging of oncogene receptors overexpressed in SCLC cells

  13. Pharmaceutical grade sodium (99mTc) pertechnetate from 99Mo/99mTc-TCM-Autosolex generator

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha

    2014-01-01

    Technetium-99m (T 1/2 = 6.02h; 140.51 keV (89%)) is the most useful radioisotope in diagnostic nuclear medicine. More than 80% of all diagnostic procedures done worldwide in nuclear medicine centre are performed with 99m Tc. Worldwide crisis of fission 99 Mo based generator in recent past had put the nuclear medicine fraternity in very harsh situation. In order to have an indigenous solution of this problem, we tried to develop a computer controlled semi automated 99 Mo/ 99m Tc generator using MEK solvent extraction technique, which utilizes abundantly available 99 Mo produced by (n,γ) reaction in BARC reactors. The aim of this work is to provide a more reliable, computer controlled module (TCM- AUTOSOLEX) for the recovery of pharmaceutical grade 99m Tc from low specific activity 99 Mo based on solvent extraction methodology

  14. Determination of kidney function with 99mTc-DTPA renography using a dual-head camera

    DEFF Research Database (Denmark)

    Madsen, Claus J; Møller, Michael L; Zerahn, Bo

    2013-01-01

    Single-head gamma camera renography has been used for decades to estimate kidney function. An estimate of the glomerular filtration rate (GFR) can be obtained using Tc-diethylenetriaminepentaacetic acid (Tc-DTPA). However, because of differing attenuation, an error is introduced when the kidney...

  15. Evaluation of usefulness of Tc-99m-GSA liver scintigraphy in chronic liver diseases

    International Nuclear Information System (INIS)

    Fukui, Hiroyuki; Kashiwagi, Toru; Kasahara, Akinori

    1991-01-01

    Liver scintigraphy was performed using a newly developed radiopharmaceutical, Tc-99m-DTPA-galactosyl-human-serum-albumin (Tc-99m-GSA), which binds specifically to the receptors on the hepatic cell surface, in 15 patients with chronic liver disease. The scintigraphy was evaluated qualitatively and quantitatively, and the results were compared with those obtained from the Tc-99m-PMT or Tc-99m-sn-phytate scintigraphy, and the liver function tests. The Tc-99m-GSA scintigraphy showed clear liver images in chronic hepatitis. However, in liver cirrhosis, the liver images were not clear and the cardiac images still existed 40 minutes after administration of Tc-99m-GSA, suggesting that the image quality of the Tc-99m-GSA scintigrams may be inferior to that of Tc-99m-sn-phytate or Tc-99m-PMT in some cases of severe liver dysfunction. The time-activity curves of the heart and liver were analyzed by non-linear regression analysis. The clearance rate from plasma (Kd) were obtained from the time-activity curve of the heart, and the hepatic uptake rate (Ku), hepatic excretion rate (Ke) and peak time of hepatic uptake-excretion curve (PT) were obtained from the time-activity curve of the liver. Kd, Ku, and PT values were more significantly decreased or prolonged in the patients with chronic hepatitis. Kd, Ku, and PT values had positive correlations with the result of the serum liver function tests, ICG-R15 and ICG-K. Ku and PT values had also correlations with the histological degree of hepatic fibrosis. On the other hand, the indices obtained using Tc-99m-PMT or Tc-99m-sn-phytate did not have correlations with the histological degrees of hepatic fibrosis. It is concluded that the liver scintigraphy using Tc-99m-GSA may be useful and give different information from those with conventional liver scintigraphies in evaluating chronic liver diseases. (author)

  16. Concentration of sup(99m)Tc from the eluate of 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Saucedo, T.; Mora, M.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1976-04-01

    A method is described to concentrate sup(99m)Tc solutions, originated in 99 Mo-sup(99m)Tc generators, independent of its age. The techniques of preparation of the different radiopharmaceuticals used in nuclear medicine are also described. (author) [es

  17. Effective visualization of suppressed thyroid tissue by means of baseline 99mTc-methoxy isobutyl isonitrile in comparison with 99mTc-pertechnetate scintigraphy after TSH stimulation.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Burroni, L

    1992-01-01

    Baseline 99mTc-MIBI thyroid scintigraphy was compared with 99mTc-pertechnetate scintigraphy after TSH stimulation in seven patients with suppressed thyroid tissue due to an autonomously functioning thyroid nodule (AFTN). In all patients the suppressed thyroid tissue was visualized by means of both baseline 99mTc-MIBI and post-TSH 99mTc-pertechnetate scintigraphy, and in some cases the former technique provided better visualization. In one patient presenting a "warm" nodule T3-suppression did not affect the nodular/extranodular uptake ratio of 99mTc-MIBI, whereas the 99mTc-pertechnetate uptake ratio increased significantly. This leads us to hypothesize that the thyroid uptake of 99mTc-MIBI is not related to TSH control, but rather to other mechanisms such as the blood flow. Since exogenous TSH is no longer available, 99mTc-MIBI scintigraphy can be successfully used in the place of repeated 99mTc-pertechnetate scintigraphy after TSH stimulation in the assessment of AFTN.

  18. The comparison of Tc99m-pertechnetate/mibi subtraction and double phase Tc99m-mibi techniques in parathyroid imaging

    International Nuclear Information System (INIS)

    Bilkay, Ue.; Erinc, R.; Karapolat, I.; Kumanlioglu, K.

    2001-01-01

    Experienced parathyroid surgeons can localize nearly %90-95 of the abnormal parathyroid glands with total thyroid bed exploration. For this reason, for the first surgical exploration preoperative imaging of the gland could be considered unnecessary. However, localization of the abnormal parathyroid tissue preoperatively could be beneficial in ectopic adenomas which consists %20 of all adenomas and also in shortening surgical procedure in single adenomas with the use of unilateral exploration. Re-exploration after an unsuccessful surgery is the most widely accepted indication for parathyroid imaging. Today, although Tc99m-MIBI is the accepted radionuclide with the advantages of giving better image quality with lower radiation dose over Tl-201, for imaging hyper functioning parathyroid tissue, there is no consensus on the ideal imaging protocol. Single-tracer double-phase imaging (STDP) and dual-tracer subtraction technique (Tc99m-pertechnetate/Tc99m-MIBI) (DTST) are proposed protocols using Tc99m-MIBI. The aim of this ongoing study is; to compare STDP imaging with DTST and to compare sensitivity of pinhole and high resolution parallel hole images in STDP protocol

  19. Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies; Resultados discordantes em cintilografias das paratireoides realizadas com tetrofosmin-99mTc e com sestamibi-99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Paulo Schiavom; Domingues, Fernanda C.; Santi Costa, Michele; Brandao, Cynthia; Oliveira, Marco A.C. de; Vieira, Jose G.H. [Fleury - Centro de Medicina Diagnostica, Sao Paulo, SP (Brazil)]. E-mail: paulo.duarte@fleury.com.br

    2007-10-15

    Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. (author)

  20. Captopril 99mTc-DTPA Renal Scintigraphy in Diagnosis of Renovascular Hypertension

    International Nuclear Information System (INIS)

    Yang, In Hyung; Lee, Dong Soo; Kim, Sung Chul

    1992-01-01

    To evaluate the sensitivity and specificity of captopril renal scan for renovascular hypertension, we employed the captopril renal scan in conjunction with renal angiography in 81 patients, 159 kidneys, who were referred to evaluate the cause of hypertension. We defined the renovascular hypertension by the criteria of demonstration of renal artery stenosis by angiography, and improvement or cure of hypertension by revascularization. Visual and quantitative evaluation of 99m Tc-DTPA renal scan was performed pre and post captopril administration. The prevalence rate of renovascular hypertension was 40% in comparing with renal angiography, and 70% in confirmed cases. The causes of renovascular hypertension in 81 patients were Takayasu's arteritis, fibromuscular dysplasia, atherosclerosis, essential hypertension, chronic pyelonephritis etc. The sensitivity and specificity of captopril renal scan in comparing with renal angiography were 80%, 86.5%, respectively and also 84.2%, 72.6% in confirmed cases of renovascular hypertension, respectively. The causes of false negative cases were nonfunctioning kidney due to complete obstruction or long duration of disease in basal scan, segmental branch artery stenosis, unknown causes, and suspicious true negative cases without confirmation. The false positive cases were abdominal aortic stenosis or aneurysm, dehydration, unknown causes, and suspicious true positive cases. We conclude that captopril renal scintigraphy is highly sensitive, reasonably specific diagnostic method and comparable to other techniques very favorably.

  1. Clinical efficacy of 99mTc-tetrofosmin myocardial scintigraphy

    International Nuclear Information System (INIS)

    Adachi, Itaru; Sugioka, Yasushi; Tanaka, Yasunori

    1993-01-01

    99m Tc-tetrofosmin is a lipophilic, cationic diphosphine which has been developed for myocardial imaging. We examined 9 patients with ischemic heart disease including 3 angina pectoris (AP), 4 old myocardial infarction (OMI), 1 AP with OMI and 1 syndrome X. One patient was examined before and after operation. Three hundred seventy MBq of 99m Tc-tetrofosmin was injected during exercise and 740 MBq at rest. And 74 MBq of 201 Tl myocardial exercise and redistribution scintigraphy was also performed to compare with 99m Tc-tetrofosmin myocardial scintigraphy. SPECT, multiple gated SPECT and anterior planar images were obtained in all cases. We calculated percent wall thickening (%WT) using multiple gated SPECT images. There was a decreased lung uptake in 99m Tc-tetrofosmin planar images compared to 201 Tl myocardial scintigraphy. Liver and Biliary system uptake in 99m Tc-tetrofosmin images was decreased with intake of milk. Segmental comparison of SPECT images showed an agreement in 9/10 of the segment between 201 Tl and 99m Tc-tetrofosmin. We could obtain excellent quality of multiple gated SPECT images in all patients. We could calculate percent wall thickening (%WT) in all patients. We conclude that 99m Tc-tetrofosmin myocardial scintigraphy should provide usefulness for detection of ischemic myocardium as same as 201 Tl myocardial scintigraphy, although the biologic characteristics of two agents were different. These data and excellent quality of multiple gated SPECT images suggest that 99m Tc-tetrofosmin is a new 99m Tc agent for evaluation of patients with ischemic heart disease. (author)

  2. Assessment of hepatic functional reserve for hepatic resection using {sup 99m}Tc-PMT scintigraphy in comparison with {sup 99m}Tc-GSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Atsushi [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    {sup 99m}Tc-diethylenetriamine-pentaacetic acid-galactosyl human serum albumin({sup 99m}Tc-GSA) scintigraphy has been reported as a useful study of hepatic functional reserve recently. We have performed {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan({sup 99m}Tc-PMT) and {sup 99m}Tc-GSA preoperatively for evaluation of hepatic functional reserve and compared the usefulness of those scintigraphy study. Twenty-four patients who were the candidates of hepatic resection underwent {sup 99m}Tc-PMT scintigraphy preoperatively. Hepatic blood flow coefficient (K value), the amount of hepatic blood flow (HBF), and the ratio of portal blood flow (PVR) were computed. {sup 99m}Tc-GSA scintigraphy was also performed within two weeks of the {sup 99m}Tc-PMT scintigraphy, and the ratio of disappearance (HH{sub 15}) and the hepatic uptake ratio (LHL{sub 15}) were computed. The relationship between K value, HBF, PVR, HH{sub 15} and LHL{sub 15} was analyzed. Their correlation with other liver function tests was also examined. K value and HBF did not show statistically significant correlations with HH{sub 15} and LHL{sub 15}, PVR correlated statistically significantly HH{sub 15} and LHL{sub 15}. K value correlated with the preoperative values of cholinesterase, Fischer ratio, {gamma}-globulin, ICGR{sub 15}, albumin, and platelet count. There was a statistically significant correlation between LHL{sub 15} and the value of cholinesterase, {gamma}-globulin, platelet count, and Fischer ratio. When the liver resection of subsegmentectomy or more was indicated in 10 patients, nine patients had LHL{sub 15} value less than 0.9 which delineated possibility of poor prognosis. However, judging from K value and HBF, liver resection was considered feasible and it was all successfully performed, resulting in good prognosis. From this study, it is suspected that {sup 99m}Tc-GSA scintigraphy reflect the severity of liver fibrosis and the amount of portal blood flows, and {sup 99m}Tc-PMT scintigraphy

  3. 99mTc-ECD and 99mTc-HM-PAO SPECT in five patients with MELAS

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Nishimaki, Hiroshi; Kitano, Masashi; Horiike, Shigeharu; Kan, Shinichi; Ishii, Katsumi; Matsubayashi, Takashi; Sakai, Fumihiko

    1998-01-01

    Cerebral perfusion was studied in five patients with mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes syndrome (MELAS), using single photon emission computed tomography (SPECT) with 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD) or 99m Tc-hexamethyl propyleneamine oxime ( 99m Tc-HM-PAO). In four cases, regional cerebral blood flow (rCBF) was evaluated by the method reported by Mastuda et al. Immediately after the stroke-like episodes, accumulation of the tracer was relatively increased in the temporooccipital lobe, and also increased rCBF was shown in the same area. However, the region showed decreased radioactivity at the chronic stage, and rCBF decreased also. These findings are consistent with positron emission tomography (PET) at the acute stage and autopsy. 99m Tc-ECD SPECT and 99m Tc-HM-PAO SPECT may be useful in the diagnosis and assessment of the progress of the MELAS. (author)

  4. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function

  5. Stability 'in vivo' and 'in vitro' of the diisopropyl-IDA sup(99m)Tc

    International Nuclear Information System (INIS)

    Verdera, E.S.; Leon, A.S.; Robles, A.M.; Correa, Angela; Oliver, Guillermo; Gamma, Santos; Lanzzeri, Stella; Mitta, A.E.A.

    1982-01-01

    The 'in vitro' and 'in vivo' stability of the diisopropyl (IDA-3) kit in solution and of the molecule labelled with sup(99m)Tc was studied. The following items were studied a) shelf life of the kit in solution b) 'in vitro' stability of the labelled molecule c) distribution and elimination kinetics d) identification and behaviour of the excretion products. Chromatographic control shows 95% yield of labelled product after 20 days storage at 4 deg C and 92% yield after 30 days in the same conditions; biological distribution was good in both cases. Regarding the 'in vitro' stability, no alteration was observed within the 4 hours after its preparation. The stability of the complex was determined by the reaction between sup(99m)TcIDA-3 and DTPA. Analysis by electrophoresis shows the complex to be stable even with DTPA concentrations 5 times higher. Kinetics of distribution and elimination of the labelled molecule, in animals, were afterwards confirmed by sequential scintigraphic images in humans. The excretion of unaltered sup(99m)Tc-IDA by biliary and urinary ways was confirmed by cromatographic and electrophoretic analysis of bladder and gall bladder content and by determination of its biological distribution. (author) [es

  6. Kinetic study on ligand exchange reaction between ethylenedicysteine and 99mTc- glucoheptonate (99mTc-GH)

    International Nuclear Information System (INIS)

    Wu, C.Y.; Ji, S.R.; Lu, C.X.; Ding, S.Y.; Chen, Z.P.; Lin, X.T.

    2002-01-01

    Aim: 99m Tc-L,L-ethylenedicysteine( 99m Tc-EC)is a new type of renal imaging agent. It can be labeled very easily and efficiently at room temperature through direct labeling at pH 12. The need for direct labeling at pH 12 does not compromise the simplicity and ease of preparation of 99m Tc-EC and its practical usefulness in daily routine. On the basis of the labeling experiments, we developed a ligand exchange labeling method, in which the labeling EC with 99m Tc can be performed at pH 8. In order to provide a theoretic basis, a detailed kinetic study of ligand exchange reaction between 99m Tc- glucoheptonate( 99m Tc-GH) and EC was carried out. Materials and Methods: 99m Tc-EC is prepared as follows: 99m Tc-GH + EC → 99m Tc-EC + GH, labeling can be easily performed by adding 99m TcO 4 - (2∼6ml generator elute) to glucoheptonate solution containing SnCl 2 .2H 2 O solution to form 99m Tc-GH, then freshly prepared 99m Tc-GH is transferred to the aqueous solution of different concentrations of EC at different pH value, after being shaken, 99m Tc-EC was formed. Radiolabeling yield(RLY) and radiochemical purity(RCP) of 99m Tc-GH and 99m Tc-EC were measured by Xinhua No.1 paper with developing system of Me 2 CO/H 2 O/con.NH 3 .H 2 O=9/3/1(V/V). 99m Tc-GH(RCP must be over 98%, 80ul, 3.6∼7.4MBq) was added to 1ml of 0.5mol/L phosphate buffer(pH 12) containing different amount of EC(150, 75, 50 and 15ug), the sample was taken out at different time intervals and RCP was determined. The solution of EC(30ul, 5g/L) was added to 1ml of 0.5mol/L phosphate buffer at different pH value(pH11, 10, 9, 8, 7), after completely vortexed, 99m Tc-GH(RCP must be over 98%, 80ul, 3.6∼7.4MBq) was then added, the sample was taken out and RCP was determined as above. The rate constant(k) of ligand exchange reaction at different concentrations of EC and different reaction pH values were calculated out by integrating. Plot ln[1/(1-RLY)] vs t(time) showed a liner relationship, and the rate

  7. 99mTc-Demotate 1: first data in tumour patients - results of a pilot/phase I study

    International Nuclear Information System (INIS)

    Decristoforo, Clemens; Gabriel, Michael; Moncayo, Roy; Maina, Theodosia; Nock, Berthold; Cordopatis, Paul

    2003-01-01

    Somatostatin receptor (SSTR) scintigraphy with indium-111 DTPA-octreotide has become a routine diagnostic procedure in oncology. However, it suffers some drawbacks concerning the limited availability, suboptimal imaging properties and elevated radiation burden of 111 In. We have recently been involved in the development of a new tetraamine-functionalised [Tyr 3 ]octreotate derivative (Demotate 1) that can be easily labelled with technetium-99m at high specific activities. 99m Tc-Demotate 1 showed promising properties in preclinical studies. In this study we report on the first experience with 99m Tc-Demotate 1 in patients. Six patients (mean age 56 years) with carcinoid tumours (n=2) or endocrine pancreatic tumours (n=4) with previously positive SSTR scintigraphy were enrolled in the study. Patients were injected with 500-600 MBq 99m Tc-Demotate 1. Clinical and laboratory parameters were controlled up to 3 months p.i. Blood samples were taken at various time points up to 24 h p.i., and urine was collected up to 24 h. Whole-body images were acquired at 15-30 min, 1-2 h, 4 h and 24 h p.i. with additional single-photon emission tomography imaging at 1-4 h. Blood excretion was very rapid, with 99m Tc-Demotate 1 detected 11 lesions while In-Oct detected ten; differences in uptake behaviour were observed in three patients. This study shows for the first time that peptides derivatised with a tetraamine ligand for labelling with 99m Tc show suitable properties for receptor imaging in patients. 99m Tc-Demotate 1 is a promising agent for the visualisation of SSTR-positive lesions in patients, allowing rapid imaging as early as 1 h p.i.; some differences are observed in pharmacokinetic behaviour compared with 111 In-DTPA-octreotide. (orig.)

  8. Status of Tc-99m and 99Mo/99mTc generator production in Bangladesh

    International Nuclear Information System (INIS)

    Abedin, Md. Zainul; Haque, Md. Azizul; Ali, Md. Ramjan; Hossain, Md. Anwar; Razzaque, Md. Abdur; Yasmin, Lyzu; Waheed, M. Fatima; Akhter, Rabeya; Mondal, Rafiuddin

    2007-01-01

    Radioisotope Production Division (RIPD) produced instant technetium-99m by solvent extraction method for several years. On R and D basis, the division produced portable sterile Tc-99m sublimation generator by irradiating titanium molybdate in the reactor. The division produced (4/batch) from imported fission Mo-99 till June 2005. Since August 2005, as per demand of the government hospitals, the division have been producing 12-14 pieces of 15 GBq chromatographic 99m Tc-generators weekly by using the new generator production plant installed last year having online Mo-99 loading system with the of producing 50 generator per batch. Development of PZC and (n,γ) 99 Mo based generator holds potential in Bangladesh. (author)

  9. Results of regular study on radionuclidic purity of sup(99m)Tc obtained from 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Vlcek, J.; Rohacek, J.; Husak, V.

    1979-01-01

    A total of 39 sup(99m)Tc eluates obtained from 9 99 Mo-sup(99m)Tc generators delivered by The Radiochemical Centre Amersham during one year was studied with regard to their radionuclide purity. Using a Ge(Li) spectrometer the contaminants 60 Co, 103 Ru, 131 I, 134 Cs, 140 La and 188 Re were found in sup(99m)Tc-eluates with average levels ranging from 2.9 x 10 -3 to 2.8 x 10 -1 per cent of sup(99m)Tc activity. The additional total body absorbed dose caused by these contaminants, as calculated from their average content in sup(99m)Tc eluates, was less than 1% of the dose due to sup(99m)Tc pertechnetate. (orig.) 891 MG/orig. 892 CS [de

  10. Measurement of glomerular filtration rate (GFR) with 99mTc-DTPA and semiconductors minidetectors: further validation of the method

    International Nuclear Information System (INIS)

    Mahlstedt, J.; Muehlbauer, J.; Schrott, K.H.; Wolf, F.

    1982-01-01

    A technique measuring external radiation with semiconductor minidetectors (SCM) by use of a portable solid state memory after bolus injection of 1mCi 99mTc-DTPA is described. The correlation of the calculated clearances to plasma creatinine levels and to endogenous creatinine clearance as well is satisfactory. This new technique is compared with a standard steady state technique (GFR-SS) using 51 Cr-EDTA. GFR-SCM is strongly correlated to GFR-SS as standard method, therefore the data provides substantial evidence that GFR-SCM is a reliable method of GFR measurement. The advantages are: fast availability of the test result especially when calculated by use of a minicomputer; ease of performance in routine work; convenience for the patient without need of compliance and low costs for the detector system

  11. Direct {sup 99m}Tc labeling of Herceptin (trastuzumab) by {sup 99m}Tc(I) tricarbonyl ion

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.-J.; Yen, C.-L.; Lo, S.-T.; Chen, K.-T. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lo, J.-M. [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu 30013, Taiwan (China)], E-mail: jmlo@mx.nthu.edu.tw

    2008-03-15

    By simply incubating Herceptin (trastuzumab) with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +} ion in saline, a significant yield of {sup 99m}Tc-labeled trastuzumab was found to be achievable. The effective labeling may be based on that trastuzumab is inherent with endogenous histidine group to which {sup 99m}Tc(I) tricarbonyl ion can be strongly bound. For practical {sup 99m}Tc labeling processing, trastuzumab was purified beforehand from the commercial product, Herceptin (Genentech) via size exclusion chromatography to remove the excipient, {alpha}-histidine and a high-labeled yield could be obtained by incubating the purified trastuzumab with [{sup 99m}Tc(CO){sub 3}(OH{sub 2}){sub 3}]{sup +}. Retention of bioactivity of the {sup 99m}Tc(I)-labeled trastuzumab was validated using a cell binding test.

  12. Successful labeling of 99mTc-MDP using 99mTc separated from 99Mo produced by 100Mo(n,2n)99Mo

    International Nuclear Information System (INIS)

    Nagai, Yasuki; Hatsukawa, Yuichi; Kin, Tadahiro; Hashimoto, Kazuyuki; Motoishi, Shoji; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke; Sato, Yuichi; Sato, Norihito; Ohta, Akio; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Kawauchi, Yukimasa; Teranaka, Tomoyuki; Takeuchi, Nobuhiro; Igarashi, Takashi

    2011-01-01

    We have for the first time succeeded in separating 99m Tc from a MoO 3 sample irradiated with accelerator neutrons free from any radioactive impurities and in formulating 99m Tc-methylene diphosphonate ( 99 mTc-MDP). 99 Mo, the mother nuclide of 99m Tc, was produced by the 100 Mo(n,2n) 99 Mo reaction using about 14 MeV neutrons provided by the 3 H(d,n) 4 He reaction at the Fusion Neutronics Source of Japan Atomic Energy Agency. The 99m Tc was separated from 99 Mo by sublimation and its radionuclide purity was confirmed to be higher than 99.99% by γ-spectroscopy. The labeling efficiency of 99m Tc-MDP was shown to be higher than 99% by thin-layer chromatography. These values exceed the United States Pharmacopeia requirements for a fission product, 99 Mo. Consequently, a 99m Tc radiopharmaceutical preparation formed by using the mentioned 99 Mo can be a promising substitute for the fission product 99 Mo, which is currently produced using a highly enriched uranium target in aging research reactors. A longstanding problem to ensure a reliable and constant supply of 99 Mo in Japan can be partially mitigated. (author)

  13. sup(99m)Tc-labeled monofluorophosphate as a skeletal imaging agent

    International Nuclear Information System (INIS)

    Ichikawa, Tsuneji; Ito, Yasuhiko; Muranaka, Akira; Yokobayashi, Tsuneo; Uchida, Masahiro

    1976-01-01

    The performance of sup(99m)Tc-monofluorophosphate was compared with those of sup(99m)Tc-pyrophosphate and sup(99m)Tc-diphosphonate in rabbits. Studies included chromatographic quality control, measurements of blood clearance, tissue distribution, urinary excretion, skeletal imaging, and measurements of the serum calcium. The labeling for sup(99m)Tc-monofluorophosphate was 98% on paper chromatography and 85% on thin layer chromatography. A large fraction of the activity of the three labeled agents was cleared very rapidly from the bloodstream: however, slow components of the curves were the highest for sup(99m)Tc-monofluorophosphate and lowest for sup(99m)Tc-diphosphonate. Three hours after injection 20% of the dose of sup(99m)Tc-monofluorophosphate was taken up by bone. The corresponding values of sup(99m)Tc-pyrophosphate and sup(99m)Tc-diphosphonate were 29.1% and 40.0% respectively. Ratio of concentration in bone to that in other major organs was highest with sup(99m)Tc-diphosphonate. Ratios were similar for both sup(99m)Tc-monofluorophosphate and sup(99m)Tc-pyrophosphate and much lower than those of sup(99m)Tc-diphosphonate. No significant differences were demonstrated in urinary excretion of the three labeled agents. Visual comparison of the scans obtained with three compounds confirmed the results of radioassay. All were excellent skeletal imaging agents, although sup(99m)Tc-diphosphonate appeared to be superior to the other two mainly because of a higher target to non-target ratio. With 50 mg of monofluorophosphate and 1 mg of stannous fluoride, no hypocalcemia was observed. (J.P.N.)

  14. Assessment of vascularity and permeability in brain tumor using SPECT and [sup 99m]Tc-DTPA-human serum albumin in relation to [sup 201]Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawara, Jyoji; Fukuoka, Seiji; Takahashi, Shuhei; Takahashi, Masaaki; Satoh, Katsuyasu; Suematsu, Katsumi; Nakamura, Jun-ichi (Nakamura Memorial Hospital, Sapporo (Japan))

    1994-02-01

    Single photon emission computed tomography (SPECT) using technetium-99m-DTPA-human serum albumin ([sup 99m]Tc-HSA-D) and thallium-201 chloride ([sup 201]Tl) was simultaneously performed on 25 patients with brain tumors; 10 with brain metastasis, 8 with astrocytoma (Gr. 3) and 7 with meningioma. The early image was obtained 10 minutes after [sup 99m]Tc-HSA-D (740 MBq) injection, and the delayed image was taken 5 hours after the injection. HSA-D index, based on the ratio of [sup 99m]Tc-HSA-D uptake in the tumor versus the cortical area, was calculated on each image, and compared with Tl index (tumor/contralateral cerebrum ratio). HSA-D delayed index was significantly greater than HSA-D early index in all tumor types (p<0.05 by the Wilcoxon ranked sign test). Linear correlation between HSA-D early index and HSA-D delayed index was significant in astrocytoma (GR. 3) (p<0.01) and meningioma (p<0.001), and a linear correlation between HSA-D delayed index and Tl index was significant in astrocytoma (Gr. 3) (p<0.05). It is concluded that HSA-D early index and delayed index could reflect tumor vascularity and permeability, respectively, and provide supplementary information for Tl index. (author).

  15. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Plachcinska, A.; Kusmierek, J.; Mikolajczak, R.; Kozak, J.; Rzeszutek, K.

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99m Tc-depreotide (Neospect, Amersham) and 99m Tc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (±) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both diopharmaceuticals differed significantly. 99m Tc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99m Tc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology - lung cancer - was revealed (5 - adenocarcinoma, 1 - squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99m Tc-depreotide scintigrams were true negative, 1 - equivocal and 5 - false positive, whereas 6 99m Tc

  16. Significance of delayed /sup 99m/Tc-PMT scintigraphy in diagnosis of hepatocellular carcinoma. Comparison between /sup 99m/Tc-PMT and /sup 67/Ga-citrate scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Yoshihisa; Nakano, Shunichi; Hashizume, Terumi and others

    1985-03-01

    The usefulness of delayed hepatobiliary imaging with /sup 99m/Tc-PMT in diagnosis of hepatocellular carcinoma was studied in 30 patients with histologically verified hepatocellular carcinoma. Of 30 patients, delayed /sup 99m/Tc-PMT images showed 13 patients (43 %) of increased radioactivity and 4 (13 %) of equilibrated radioactivity in carcinoma as compared with that in the surrounding normal liver tissues. Furthermore, 3 of 6 patients who showed no filling defects in /sup 99m/Tc-Sn colloid liver images, showed increased uptake of radioactivity in carcinoma in delayed /sup 99m/Tc-PMT images. These results suggest that the complementary use of delayed /sup 99m/Tc-PMT imaging to /sup 99m/Tc-Sn colloid liver imaging is useful for detecting hepatoma lesions. The hepatic lesions were positively visualized on /sup 99m/Tc-PMT and/or /sup 67/Ga-citrate images in 21 (70 %) of 30 patients. These results indicate that use of delayed /sup 99m/Tc-PMT and /sup 67/Ga-citrate imaging in combination is useful for positive visualization of hepatocellular carcinoma.

  17. sup(99m)Tc-2-mercaptopropionylglycine

    International Nuclear Information System (INIS)

    Saji, Hideo; Odori, Teruo; Morita, Rikushi; Yokoyama, Akira; Tanaka, Hisashi.

    1979-01-01

    Labeling of 2-mercaptopropionylglycine (2-MPG) with sup(99m)Tc, was studied and its chemical characteristics were examined. Further, biliary excretion behavior of this complex was comparatively estimated in mice, rats and rabbits. sup(99m)Tc-2-MPG was rapidly excreted in large quantities into the bile in mice and rats: within 1 hr after injection, 51% of the injected dose was recovered from the bile in rats. On the other hand, the ligand exchange reaction between this complex and penicillamine indicates that a low hydrolyzed sup(99m)Tc species is coordinated with 2-MPG. These results suggest that a low hydrolyzed sup(99m)Tc state is an effective feature in biliary excretion behavior of sup(99m)Tc compounds. Another interesting in vivo behavior of sup(99m)Tc-2-MPG is the difference observed in mice and rabbits: in mice, very high sup(99m)Tc activity is concentrated in the gallbladder and the clearance from tissues other than the gallbladder is rapid, whereas in rabbits, although a rapid and high excretion into the gallbladder is observed, a considerable high sup(99m)Tc activity is retained in the liver and the kidney. One reason for this different in vivo behavior is the low stability of this complex at high dilution: a big animal has the large dilution volume which lead to higher decomposition estimated by the higher liver and kidney retention or the lower bile excretion. In conclusion, studies carried on sup(99m)Tc-2-MPG showed a good biliary excretion behavior but an in vivo unstableness in big animals. (author)

  18. 99mTc-HYNIC-derivatized ternary ligand complexes for 99mTc-labeled polypeptides with low in vivo protein binding

    International Nuclear Information System (INIS)

    Ono, Masahiro; Arano, Yasushi; Mukai, Takahiro; Fujioka, Yasushi; Ogawa, Kazuma; Uehara, Tomoya; Saga, Tsuneo; Konishi, Junji; Saji, Hideo

    2001-01-01

    6-Hydrazinopyridine-3-carboxylic acid (HYNIC) is a representative agent used to prepare technetium-99m ( 99m Tc)-labeled polypeptides with tricine as a coligand. However, 99m Tc-HYNIC-labeled polypeptides show delayed elimination rates of the radioactivity not only from the blood but also from nontarget tissues such as the liver and kidney. In this study, a preformed chelate of tetrafluorophenol (TFP) active ester of [ 99m Tc](HYNIC)(tricine)(benzoylpyridine: BP) ternary complex was synthesized to prepare 99m Tc-labeled polypeptides with higher stability against exchange reactions with proteins in plasma and lysosomes using the Fab fragment of a monoclonal antibody and galactosyl-neoglycoalbumin (NGA) as model polypeptides. When incubated in plasma, [ 99m Tc](HYNIC-Fab)(tricine)(BP) showed significant reduction of the radioactivity in high molecular weight fractions compared with [ 99m Tc](HYNIC-Fab)(tricine) 2. When injected into mice, [ 99m Tc](HYNIC-NGA)(tricine)(BP) was metabolized to [ 99m Tc](HYNIC-lysine)(tricine)(BP) in the liver with no radioactivity detected in protein-bound fractions in contrast to the observations with [ 99m Tc](HYNIC-NGA)(tricine) 2. In addition, [ 99m Tc](HYNIC-NGA)(tricine)(BP) showed significantly faster elimination rates of the radioactivity from the liver as compared with [ 99m Tc](HYNIC-NGA)(tricine) 2. Similar results were observed with 99m Tc-labeled Fab fragments where [ 99m Tc](HYNIC-Fab)(tricine)(BP) exhibited significantly faster elimination rates of the radioactivity not only from the blood but also from the kidney. These findings indicated that conjugation of [ 99m Tc](HYNIC)(tricine)(BP) ternary ligand complex to polypeptides accelerated elimination rates of the radioactivity from the blood and nontarget tissues due to low binding of the [ 99m Tc](HYNIC)(tricine)(BP) complex with proteins in the blood and in the lysosomes. Such characteristics would render the TFP active ester of [ 99m Tc](HYNIC)(tricine)(BP) complex

  19. Assessment of renal function with 99Tcm-DTPA renal dynamic imaging in neonatal hydronephrosis

    International Nuclear Information System (INIS)

    Jiang Lixin; Guo Zongyuan; Wu Rongde; Yu Qihai; Liu Zhanfeng

    2004-01-01

    Objective: To assess the renal function in neonatal hydronephrosis with 99 Tc m -DTPA renal imaging. Methods: Eighteen unilateral hydronephrotic kidneys and 12 normal kidneys were studied by 99 Tc m -DTPA renal dynamic imaging , and glomerular filtration rate (GFR) quantitative analysis was also performed. Blood urea nitrogen (BUN), serum creatinine (SCr) and hemoglobin (Hb) were determined simultaneously and the correlations between GFR and each of these parameters were analyzed. Results: Positive correlation was discovered between GFR and Hb in neonates with moderate or severe hydronephrosis (r=0.414, 0.667, P 0.05). The renal function was decreased significantly in moderate and severe neonatal hydronephrosis (P 99 Tc m -DTPA renal dynamic imaging GFR is an ideal marker for estimating renal function in neonatal hydronephrosis; SCr could be a marker for renal damage especially in moderate and severe neonatal hydronephrosis; BUN could not be a marker for evaluating renal function in neonatal hydronephrosis. Neonates with hydronephrosis should be referred for surgical procedures as soon as possible in the early stage

  20. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m

    International Nuclear Information System (INIS)

    Monteiro, Elisiane de Godoy

    2012-01-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ( 99 mTc), obtained from 99 Mo/ 99 mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in 99m Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ( 99 mTcO 4 - ) and technetium colloidal (99mTcO 2 ) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with 99m Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. 99m TcO 4 - eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL 1 (1,5 mCi mL 1 ) of final radioactive concentration. The % 99m TcO 4 - , % 99m TcO 2 and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was necessary to search alternatives to replace ITLC-SG plate in the radiochemical control

  1. The role of Tc-99m IDA hepatobiliary and Tc-99m colloid hepatic imaging in primary biliary cirrhosis

    International Nuclear Information System (INIS)

    Aburano, T.; Yokoyama, K.; Shuke, N.; Kinuya, S.; Takayama, T.; Tonami, N.; Hisada, K.

    1991-01-01

    To assess the presence of primary biliary cirrhosis, 15 patients at various histopathologic stages were studied by Tc-99m IDA hepatobiliary and/or Tc-99m colloid hepatic imaging. In the earlier stages (I and II), seven of eight patients (88%) showed uniform hepatic retention of Tc-99m IDA. Of seven patients in the same stage, however, four (57%) showed no abnormality on Tc-99m colliod imaging. In three of these four negative patients (75%), uniform hepatic retention of Tc-99m IDA was noted. In the later stages (III and IV), all seven patients showed decreased clearance with or without delayed tracer appearance in the intestine and prominent hepatic retention on Tc-99m IDA imaging; with Tc-99m colloid imaging there was enlargement of the spleen and increased activity in the spleen and bone marrow. Thus, Tc-99m IDA imaging is considered to be more useful in revealing this functional disorder at the earlier stage of primary biliary cirrhosis and in evaluating progression from an earlier to a later stage of disease. Tc-99m colloid imaging also effectively evaluated progression

  2. Evaluation of (99)  (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99)  (m)Tc-sestamibi.

    Science.gov (United States)

    Bu, Lihong; Li, Renfei; Jin, Zhongnan; Wen, Xiaofei; Liu, Shuang; Yang, Baofeng; Shen, Baozhong; Chen, Xiaoyuan

    2011-02-01

    (99)  (m)TcN-MPO ([(99)  (m)TcN(mpo)(PNP5)](+): mpo = 2-mercaptopyridine oxide and PNP5 = N-ethoxyethyl-N,N-bis[2-(bis(3-methoxypropyl)phosphino)ethyl]amine) is a cationic (99)  (m)Tc-nitrido complex, which has favorable biodistribution and myocardial uptake with rapid liver clearance in Sprague Dawley rats. The objective of this study was to compare the biodistribution and pharmacokinetics of (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi in normal dogs, and to evaluate the potential of (99)  (m)TcN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Five normal mongrel dogs were injected intravenously with (99)  (m)TcN-MPO. Venous blood samples were collected via a femoral vein catheter at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 60, and 90 min post-injection (p.i.). Anterior-posterior planar images were acquired by γ-camera at 10, 20, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around the heart, liver, and lungs. The heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in the liver and lung ROI, respectively. For comparison, (99)  (m)Tc-sestamibi was also evaluated in the same five dogs. The interval period between the two examinations was 1 week to eliminate possible interference between these two radiotracers. In addition, single positron emission computed tomography (SPECT) images in the canine infarct model were collected 24 h after myocardial infarction at 30 and 60 min after the administration of (99)  (m)TcN-MPO (n = 4) or (99)  (m)Tc-Sestamibi (n = 4). It was found that (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi displayed very similar blood clearance characteristics during the first 90 min p.i. Both (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min and less than 5% at 30 min p.i. (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi both showed good

  3. Diagnosis of pulmonary infections with HIV (+) patients. Brought of aerosol DTPA-Tc99m and of Ga67 citrate

    International Nuclear Information System (INIS)

    Banzo, I.; Quirce, R.; Serrano, J.; Jimenez, J.; Tabuenca, O.; Carril, J.M.

    1993-01-01

    The pulmonary clearance of aerosol DTPA-Tc99m is a technology easy to use, well support by patients with immediate results. With the pneumonia at Pneumocystis Carinii (PPC), the clearance is more sensitive and more specific than the thoracic scintigraphy with Ga67. Used with a thorax radiography, results will lead to three directions: High probability of PPC, di phasic curve and very fast T50, equal inferior to 5,10 mn. Low probability of PPC, monoexponential curve and abnormal thorax radiography or di phasic curve with a value T50 superior to 5,10 mn. With these patients other explorations will be made (Ga67, biopsy) and if possible search pulmonary tuberculosis. Extra pulmonary pathology: monoexponential curve associated with a normal thoracic radiography. 2 figs

  4. A modified Tc-99m-phytate colloid for liver-spleen imaging

    International Nuclear Information System (INIS)

    Davis, M.A.; Kaplan, M.L.; Ahnberg, D.S.; Cole, C.N.

    1977-01-01

    The results of a comparison of the in vivo biologic properties of sup(99m)Tc-stannous phytate and sup(99m)Tc-stannous phytate precipitated in vitro by the addition of calcium ion, undertaken because of an interest in increasing the splenic uptake of sup(99m)Tc-phytate to a level similar to that obtained with sup(99m)Tc-sulfur colloid, are reported. It was found that: (1) The similarity in the organ distribution values of sup(99m)Tc-phytate and sup(99m)Tc-sulfur colloid is species related (rodents) and decreased splenic uptake of the phytate colloid is found in other primates and man. (2) The gamma scintillation camera with computer region of interest capability is an extremely useful technique for studying the biodistribution and pharmacokinetics of radiodiagnostic agents in primates, where the cost of the animals prohibits the use of the sequential sacrifice technique. (3) The addition of calcium ion to the sup(99m)Tc-phytate complex produces an in vitro colloid with a particle size and biologic distribution very similar to that obtained with sup(99m)Tc-sulfur colloid. (U.K.)

  5. Improved brain scan specificity utilizing /sup 99m/Tc-pertechnetate and /sup 99m/Tc(Sn)-diphosphonate

    International Nuclear Information System (INIS)

    Fischer, K.C.; McKusick, K.A.; Pendergrass, H.P.; Potsaid, M.S.

    1975-01-01

    Each of 36 patients was studied with two separate brain scans performed sequentially after the injection of 20 mCi of /sup 99m/Tc-pertechnetate or 20 mCi of /sup 99m/Tc(Sn)-diphosphonate. The resulting scans were qualitatively compared, and lesion-to-nonlesion ratios of activity determined. Diagnoses were established by clinical criteria and were supported in the majority of cases by computerized axial tomography or roentgen angiography or both. Histologic confirmation was available in five cases of tumor and in the single cases of subdural hematoma and cerebral abscess. Of 22 cerebral infarctions, 15 were better demonstrated with /sup 99m/Tc-(Sn)-diphosphonate than with /sup 99m/Tc-pertechnetate. Of the seven remaining cases, three were visualized equally well with each agent, and three were better demonstrated with /sup 99m/Tc-pertechnetate. One was not seen with either agent. Of the 12 tumors, 11 were visualized better with /sup 99m/Tc-pertechnetate than with /sup 99m/Tc(Sn)-diphosphonate while in one case the lesion was seen equally as well with both agents. In no case was a lesion definitely seen with one radio- pharmaceutical and not with the other. These results indicate that this dual method is helpful in differentiating gliomas and metastases from cerebral infarctions. (U.S.)

  6. Approaches in the design of 99mTc based peptide radiolabelling for tumour targeting

    International Nuclear Information System (INIS)

    Yokoyama, A.; Horiuchi, K.; Arano, Y.

    2001-01-01

    One of the major drawbacks in diagnostic and/or therapeutic uses of peptides radiolabelled with radiometals via bifunctional chelating agents (BCA) is their accumulation in excretory organs such as liver or kidney. Thus, the aim of the project is centred in the search for chemical and radiochemical approaches to reduce radioactivity accumulated in excretory organs while preserving the in vivo receptor binding affinity of the peptide. During the first stage a suitable procedure using the F-moc-chemistry (solid phase) was developed and synthesis of DTPA-D-Phen1-Octreotide and DTPA-L-Phen1-Octreotide was carried out. During the synthesis, the need to improve the yield demanded the synthesis of a DTPA derivative holding only one reactive carboxylic group to avoid side intermolecular reaction. The availability of both isomeric conjugated octreotide led to their radiolabelling with 111 In. Their metabolic studies in animals indicated that the degradation rate of the peptide containing the natural aminoacid, 111 In DTPA-L-Phen1-Octreotide, was slightly higher than the corresponding D-aminoacid derivative, as expected. Stability of the peptide during radiolabelling with 99m Tc was then studied, requiring the use of variable agents such as ascorbic acid, dithionite and stannous ion. The selected peptide, RC-160, was provided by the IAEA and, as reference compounds, corresponding iodinated and radioiodinated peptides were synthesized. Demonstration of the stability of the peptide was carried out using disodium 2-nitro-5-thiosulfobenzoate (NTBS) and the lack of Bunte salt formation served as an indication of the stability of the disulfide bond under various mild conditions required for the future radiolabelling with 99m Tc. The knowledge gained served in moving to the next stage of 99m Tc radiolabelling using HYNIC as the BCA and tricine as co-ligands. The biodistribution studies demonstrated great accumulation on excretory organs. This led us to look for a model protein

  7. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  8. Electrolytic 99mTcO4- reduction: a different pathway to obtain 99mTc-labelled compounds

    International Nuclear Information System (INIS)

    Savio, E.; Kremer, C.; Gambino, D.; Kremer, E.; Leon, A.

    1991-01-01

    Electrolytic reduction of 99m TcO 4 - at inert electrodes to obtain 99m Tc cationic complexes and in vitro stability of labelled compounds were studied. Amines were used as neutral N-donor ligands and a systematic analysis of various parameters involved in the reduction process was performed. Usefulness of electrolytic reduction was proved as an alternative 99m Tc-labelling method. Its most important advantages are: production of complexes with a high radiochemical purity, negligible presence of red-hyd- 99m Tc, lack of foreign materials, simplicity of development and possibility of further applications. (author)

  9. Study of the renal function in diabetic patients by 99sup(m)Tc-DTPA and 131I-Hippuran

    International Nuclear Information System (INIS)

    Silva, N.C. da.

    1981-01-01

    Twenty-six patients with diabetes in different stages were studied by radioisotopic techniques in an attempt to detect early alterations of renal function. Renal scintillography, 99 sup(m)Tc-DTPA glomerular filtration rate, renogram and 131 I-Hippuran effective renal plasma flow were the techniques employed. Renal evaluation was filled out by biochemical analysis of plasmatic urea and creatinine, 24 h-proteinuria and funduscopy of patients. The renal disease of diabetic patient is a result of the sum of many factors and subclinical functional alterations that appear can be ascribed to reversible hemodynamic alterations, such as decrease of plasma flow with increase of ultrafiltrated plasma fraction and of glomerular filtration. Mechanisms that lead to these alterations are not yet stablished. This work suggests that the diabetic patients well metabolic compensated present less incidence of degenerative complications, among them renal lesions. (Author) [pt

  10. Assessment of bacterial translocation in obstructive jaundice using Tc-99m Escherichia coli

    International Nuclear Information System (INIS)

    Diniz, Simone Odilia Fernandes; Nelson, David Lee; Barbosa, Alfredo Jose Afonso; Araujo, Ivana Durval; Machado, Leonardo Augusto da Silva; Bernardo Filho, Mario

    2005-01-01

    In obstructive jaundice, the passage of bacteria and endotoxins through the intestine wall to reach the systemic circulation is associated with septicemia, renal failure and pulmonary dysfunction. The aim of this work was to investigate bacterial translocation utilizing 99m Tc-E.coli in an experimental model of obstructive jaundice. The levels of bilirubin in rats that were subjected to ligature of the bile duct were significantly increased when compared to control animals (p 99m Tc-E.coli to the mesenteric lymphatic nodules, liver, spleen or lungs of the rats that suffered ligature of the bile duct (p > 0.05). The evaluation of the intestinal permeability using 'per os' administration of 99m Tc-DTPA showed 1.61 ± 0.57% and 1.39 ± 0.72% of radioactivity in the urine of the control and jaundice animals, respectively. The histological analysis of the distal wall of the ileum showed that the covering epithelium and the crypt were morphologically preserved in both groups. The seven-day period after the ligature of the bile duct may not have been long enough to promote modifications in intestinal wall to occur so as to permit the passage of Tc-99m E.coli. (author)

  11. Radiopharmaceuticals to 99mTc

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    Studies about 99m Tc had demonstrated that have favorable properties for support diagnostic proceedings in nuclear medicine. This physical and chemical properties used for obtain another radiopharmaceuticals have been employed through re actives kits labelled with Tc 99m . A brief description was given about 99m utilities in diagnostic techniques such as endothelium reticular system,renal and hepatic studies,bone scintillators,cardiac diagnostic and cerebral perfusion

  12. Differentiation of malignant and degenerative benign bone disease using Tc-99m Citrate and Tc-99m MDP scintigraphy

    International Nuclear Information System (INIS)

    Jin, J.; Guo, R.; Li, S.-J.; Ren, Y.; Zhang, C.; Zhang, X.

    2007-01-01

    Full text: For the evaluation of bone metastases in patients (pts) with cancer, 99mTcMDP bone scintigraphy is an important tool, but some limitations exist. One of these is the differential diagnosis of malignant and degenerative benign bone disease. The aim of this study was to differentiate them using 99mTcCitrate and 99mTcMDP scintigraphy. Methods: 39 pts (92 lesions) with known malignant or degenerative benign bone disease were studied. 23 pts had malignant bone disease (48 lesions, group 1), the other 16 pts had degenerative benign bone disease (44 lesions, group2), for which the results of 99mTcMDP scintigraphy were positive. In both groups, 99mTcCitrate scintigraphy was performed within a time interval of 2-7 days after 99mTcMDP scintigraphy (555∼740MBq. static, 3hr, planar or SPECT i m a g e s w h e n r e q u i r e d ) . The 99mTccitrate/99mTcMDP lesion-to-background radioisotope uptake ratio (RUR) was calculated for each lesion. Conventional techniques (histopathology, X-ray, CT, MRI and clinical follow up) were considered to be proof of the presence of bone metastases and degenerative benign bone disease. Results: Uptake of 99mTcMDP in the two groups is the same (1.96±0.25 vs. 1.87±0.21; t=1.178, P>0.20), while in 99mTcCitrate image, malignant lesions demonstrated a higher uptake of lesion activity than that of benign degenerative lesions (1.47±0.42 vs. 1.09±0.38; t=2.887, P<0.01). The mean 99mTccitrate/99mTcMDP RUR in the malignant group was significantly higher than the mean in the benign group (0.78±0.21 vs. 0.54±0.19; t=3.646, P<0.001). Conclusions: The preliminary results of the study confirm the usefulness and feasibility of 99mTcCitrate scintigraphy for differentiating malignant from benign degenerative lesions seen as areas of increased activity on 99mTcMDP bone scintigraphy. (author)

  13. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules.

    Science.gov (United States)

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99mTc-depreotide (Neospect, Amersham) and 99mTc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (+/-) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both radiopharmaceuticals differed significantly. 99mTc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99mTc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology--lung cancer--was revealed (5--adenocarcinoma, 1--squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99mTc-depreotide scintigrams were true negative, 1--equivocal and 5--false positive, whereas 6 99mTc

  14. Preparation and biological characteristics of 99mTc-diol a renal agent

    International Nuclear Information System (INIS)

    Castanheira, I.; Paulo, A.; Neves, M.; Patricio, L.; Sawas-Dimopoulou, C.

    1993-01-01

    The present work concerns the production of 1,2-dihydroxypropyl-1-phosphonic acid (diol) by acid hydrolysis of (-cis) 1,2-epoxypropylphosphonic acid (phosphomycin), and its formation as a kit easily labeled with [ 99m Tc]pertechnetate. Biodistribution studies and whole-body autoradiographies in mice show that 99m Tc-diol has a specific affinity for the kidneys: it is rapidly cleared from the blood and excreted in urine. Part of the injected activity remains in the kidney cortex sufficiently long to permit kidney imaging. In comparison with other agents which also localize in the kidney cortex, such as 99m Tc-DMSA and 99m Tc-glucoheptonate ( 99m Tc-GHA), the main differences are the following: the peak of renal activity is reached early in the 5 min post-injection period for 99m Tc-diol, only at about 10 min post-injection for 99m Tc-GHA and after 3 h post-injection for 99m Tc-DMSA. The uptake of 99m Tc-diol by other organs, especially by bones, is much smaller than in the case of 99m Tc-DMSA. Unlike 99m Tc-DMSA, the biodistribution of 99m Tc-diol is not significantly influenced by acid-base imbalance. Moreover, the retention effect of hyperuricemia on 99m Tc-diol blood clearance and kidney excretion could be the result of a competition mechanism between this radiopharmaceutical and uric acid for a common transport system. The above biological characteristics suggest that 99m Tc-diol is a kidney radiopharmaceutical with an ability for functional and imaging studies. (author)

  15. 99mTc-labelled HYNIC-minigastrin with reduced kidney uptake for targeting of CCK-2 receptor-positive tumours

    International Nuclear Information System (INIS)

    Guggenberg, E. von; Gabriel, M.; Virgolini, I.J.; Decristoforo, C.; Dietrich, H.; Skvortsova, I.

    2007-01-01

    Different attempts have been made to develop a suitable radioligand for targeting CCK-2 receptors in vivo, for staging of medullary thyroid carcinoma (MTC) and other receptor-expressing tumours. After initial successful clinical studies with [DTPA 0 ,DGlu 1 ]minigastrin (DTPA-MG0) radiolabelled with 111 In and 90 Y, our group developed a 99m Tc-labelled radioligand, based on HYNIC-MG0. A major drawback observed with these derivatives is their high uptake by the kidneys. In this study we describe the preclinical evaluation of the optimised shortened peptide analogue, [HYNIC 0 ,DGlu 1 ,desGlu 2-6 ]minigastrin (HYNIC-MG11). 99m Tc labelling of HYNIC-MG11 was performed using tricine and EDDA as coligands. Stability experiments were carried out by reversed phase HPLC analysis in PBS, PBS/cysteine and plasma as well as rat liver and kidney homogenates. Receptor binding and cell uptake experiments were performed using AR4-2J rat pancreatic tumour cells. Animal biodistribution was studied in AR4-2J tumour-bearing nude mice. Radiolabelling was performed at high specific activities and radiochemical purity was >90%. 99m Tc-EDDA-HYNIC-MG11 showed high affinity for the CCK-2 receptor and cell internalisation comparable to that of 99m Tc-EDDA-HYNIC-MG0. Despite high stability in solution, a low metabolic stability in rat tissue homogenates was found. In a nude mouse tumour model, very low unspecific retention in most organs, rapid renal excretion with reduced renal retention and high tumour uptake were observed. 99m Tc-EDDA-HYNIC-MG11 shows advantages over 99m Tc-EDDA-HYNIC-MG0 in terms of lower kidney retention with unchanged uptake in tumours and CCK-2 receptor-positive tissue. However, the lower metabolic stability and impurities formed in the labelling process still leave room for further improvement. (orig.)

  16. Instant thin layer chromatography (ITLC) - the most true and convenient method for the determination of radiochemical purity of Tc-99m Labeled radiopharmaceuticals

    International Nuclear Information System (INIS)

    Anwar-Ul-Azim, M.; Ansari, M.I.H.

    2007-01-01

    Full text: Determination of radiochemical purity usually involves paper chromatography method or some column chromatography such as ion exchange or gel filtration technique. In this study, a modified chromatography method with thin-layer support called instant thin Layer chromatography (ITLC) was used for the measurement of radiochemical purity. The aim of the study was to present instant thin layer chromatography-Silica-Gel (ITLC-SG) technique as a fairly rapid , convenient and inexpensive system for the screening of radiochemical impurities of 99mTc-labeled radiopharmaceuticals resulting from physical , chemical and/or radiation decomposition. Materials and Methods: The experiment was carried out at the Institute of Nuclear Medicine and Ultrasound, Dhaka for a period of 10 months from August '05 to May '06. Radiochemical purity of seven types of 99mTc-labeled radiopharmaceuticals, namely 99mTc-DTPA,99mTc- MI I, 99m Tc - HDP, 99m Tc - DMSA, 99m Tc - Tetofosmin, 99mTc-Fyton and 99mTc-ECD were measured by the use of two solvent dual-instant thin layer chromatography systems. Commercially available instant thin layer chromatography plate ( 20cm x20cm) impregnated with silica gel (ITLC-SG: Merck, Germany) was used as a stationary phase for the measurement of radiochemical impurities.Acetone, Ethyl methyl ketone, chloroform and methanol were used to measure the amount of free pertechnetate in the labelled radiopharmaceuticals and 0.9% saline was used in all cases as solvent (Mobile phase) to measure the amount of the hydrolyzed-reduced technetium colloid. Results: The results showed that the measured radiochemical purity of 99mTc-DTPA, 99mTc-MIBI, 99mTc-HDP, 99mTc-DMSA, 99mTc-Tetofosmin, 99mTc-Fyton and 99mTc-ECD were acceptable for all the studied samples except two samples of 99mTc-MIBI, one sample of 99mTc-Fyton and two samples of 99mTc-ECD, where the measured radiochemical purity were not within the acceptable RCP limits of commonly used radiopharmaceuticals (RCP

  17. Usefulness of L,L-ethylenedicysteine - 99mTc complex (EC-99mTc) for the kidney investigations

    International Nuclear Information System (INIS)

    Surma, M.J.; Wiewiora, J.; Kapuscinksi, J.; Liniecki, J.

    1992-01-01

    To assess the usefulness of own EC- 99m Tc complex for the kidney function examination, the renoscintigraphy with EC- 99m Tc and clearance determinations were performed. During renoscintigraphy the kidney images were of superb quality, with overlaying organs (liver, spleen) not visualized. Renograms showed typical shapes, their TMAX and T1/2 values being insignificantly different from the obtained with other radiopharmaceuticals, used in renoscintigraphy (MAG 3 , hippuran). Very strict correlations were found between values of EC- 99m Tc and OIH- 131 I clearances (r=0.91) and excretion rate constants (r=0.92) of both radiopharmaceuticals. The correlation enabled formulation of an equation by which ERPF could be established from EC- 99m Tc clearance: ERPF OIH =1.245 x Cl EC +51.52. On the basis of this equation a lower boundary of the normal EC- 99m Tc clearance was established; it amounts to 300 ml/min/1.73 m 2 . (author). 17 refs, 5 figs, 1 tab

  18. Evaluation of [99mTc/EDDA/HYNIC0]octreotide derivatives compared with [111In-DOTA0,Tyr3, Thr8]octreotide and [111In-DTPA0]octreotide: does tumor or pancreas uptake correlate with the rate of internalization?

    Science.gov (United States)

    Storch, Daniel; Béhé, Martin; Walter, Martin A; Chen, Jianhua; Powell, Pia; Mikolajczak, Renata; Mäcke, Helmut R

    2005-09-01

    Radiolabeled somatostatin analogs are important tools for the in vivo localization and targeted radionuclide therapy of somatostatin receptor-positive tumors. The aim of this study was to compare 3 somatostatin analogs designed for the labeling with (99m)Tc (where HYNIC is 6-hydrazinopyridine-3-carboxylic acid): 6-hydrazinopyridine-3-carboxylic acid(0)-octreotide (HYNIC-OC/(99m)Tc-(1)), [HYNIC(0),Tyr(3)]octreotide (HYNIC-TOC/(99m)Tc-(2)), and [HYNIC(0),Tyr(3),Thr(8)]octreotide (HYNIC-TATE/(99m)Tc-(3)), using ethylenediamine-N,N'-diacetic acid (EDDA) as a coligand. In addition, we compared the (99m)Tc-labeled peptides [(111)In-diethylenetriaminepentaacetic acid(0)]octreotide ([(111)In-DTPA]-OC) and [(111)In-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid(0),Tyr(3),Thr(8)]octreotide ([(111)In-DOTA]-TATE) with regard to the rate of internalization and the biodistribution in AR4-2J (expressing the somatostatin receptor subtype 2) tumor-bearing rats. The main attention was directed toward a potential correlation between the rate of internalization and the tumor or pancreas uptake. Synthesis was performed on solid phase using a standard Fmoc strategy. Internalization was studied in cell culture (AR4-2J) and biodistribution was studied using a Lewis rat tumor model (AR4-2J). The 5 radiopeptides showed a specific internalization into AR4-2J cells in culture (as shown by blocking experiments). The rate of internalization of the 5 radiopeptides differed significantly according to the following order: (99m)Tc-(1) approximately = [(111)In-DTPA]-OC EDDA/HYNIC]-TATE are suitable candidates for clinical studies.

  19. Development of 99mTc labelled somatostatin analogues with high affinity for somatostatin receptors

    International Nuclear Information System (INIS)

    Maina, T.; Nock, B.; Nicolopoulou, A.; Tsipra, C.; Poppe, M.; Chiotellis, E.

    2001-01-01

    A recent development in oncology involves the use of metabolically stabilized peptide hormone analogues labelled with metallic radionuclides for the diagnosis or therapy of malignant disease. This approach was successfully applied for the first time in the visualization of somatostatin positive tumours and their metastases with 111 In DTPA-octreotide. In an effort to obtain a 99m Tc somatostatin receptor affine radioligand we describe herein the synthesis, radiochemistry and preliminary biological evaluation of two novel 99m Tc labelled somatostatin analogues, N 4 -TOC and N 4 -RC-160. In these compounds a tetraamine bifunctional unit was covalently attached to the N-terminal (D)Phe 1 of the peptide chain using Boc-protection strategies. The peptide conjugates were purified by high performance liquid chromatography (HPLC) and characterized by UV/Vis and ES-MS spectroscopies. As revealed by HPLC, 99m Tc labelling was quantitative under mild conditions, leading to a single 99m Tc species in high specific activities. Affinity of 99m Tc N 4 -TOC for the somatostatin receptor, as determined by in vitro binding assays in rat brain cortex membranes, was found unaffected by the presence of the bulky metal chelate. The binding properties of 99m Tc N 4 -RC-160 could not be determined by this assay due to an extremely high non-specific binding of this radioligand, and will be shortly investigated by other methods. Tissue distribution in healthy mice revealed that 99m Tc N 4 -TOC is clearing mainly through the kidneys and the urinary tract whereas 99m Tc N 4 -RC-160 shows a high accumulation in the liver as a result of its lipophilicity. Analysis of urine samples by HPLC showed that 99m Tc N 4 -TOC is excreted integer from the body of mice, while 99m Tc N 4 -RC-160 is totally transformed to an unidentified hydrophilic metabolite in vivo. The location of this metabolism is currently investigated. In vivo blocking experiments using animals pre-treated with 50 μg octreotide

  20. Achalasia diagnosed by {sup 99m}Tc pertechnetate scintigraphy; Diagnose einer Achalasie durch {sup 99m}Tc-Pertechnetat-Szintigraphie

    Energy Technology Data Exchange (ETDEWEB)

    Mikosch, P. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Gallowitsch, H.J. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Kresnik, E. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie; Lind, P. [Landeskrankenhaus Klagenfurt (Austria). Abt. fuer Nuklearmedizin und Spezielle Endokrinologie

    1997-06-01

    A 73-year-old patient presented a {sup 99m}Tc scintiscan with a focal tracer accumulation left and caudal of the thyroid gland. Further investigations with sonography, CT, esophagoscopy and barium swallow provided the diagnosis of achalasia as the reason for focal {sup 99m}Tc retention caudal of the thyroid gland. Explanation for {sup 99m}Tc accumulation within the esophagus may be the nonspecific accumulation of {sup 99m}Tc not only in the thyroid gland but also in the salivary glands. Excretion of the tracer follows with the saliva. Structural and motor disorders of the esophagus can thus lead to focal tracer retention within the esophagus simulating thyroid tissue. (orig.) [Deutsch] Eine 73jaehrige Patientin zeigte bei der {sup 99m}Tc-Schilddruesenszintigraphie eine von der Schilddruese abgesetzte deutliche fokale Speicherung links kaudal der Schilddruese. Die weitere diagnostische Abklaerung mittels Sonographie, CT, Oesophagoskopie und videoassistiertem Kontrastmittelschluckakt ergab als Ursache der {sup 99m}Tc-Speicherung eine Achalasie. Die Erklaerung einer {sup 99m}Tc-Speicherung in der Speiseroehre waere die unspezifische {sup 99m}Tc-Aufnahme in den Speicheldruesen mit nachfolgender Tracerelimination ueber den Speichel. Depotbildungen von Speichel bei Erkrankungen der Speiseroehre, die mit einer Transportstoerung des Speichels verbunden sind, koennen dadurch Schilddruesengewebe vortaeuschen. (orig.)

  1. Technetium-99m DTPA inhalation scintigraphy in patients treated with fluoxetine and maprotiline: preliminary results

    International Nuclear Information System (INIS)

    Kaya, G.C.; Durak, H.; Oezdogan, Oe.; Sayit, E.; Degirmenci, B.; Derebek, E.

    2000-01-01

    Drug-metabolising enzymatic activities have been detected in tracheobronchiolar, bronchiolar and alveolar regions in the lungs. Induction of phospholipidosis by amine drugs such as clorphentermine has also been shown. This study aimed to investigate the effect of fluoxetine and maprotiline, which contain amine groups in their structure, on pulmonary epithelial membrane permeability. Twenty-seven patients (mean age 36±12 years) with various psychiatric problems, of whom 17 were treated with fluoxetine and 10 with maprotiline, were included in this study. Technetium-99m diethylene triamine penta-acetic acid (DTPA) aerosol inhalation scintigraphy was performed before and after 4-6 weeks of therapy. Following the inhalation of 1480 MBq 99m Tc-DTPA for 3 min, lung images in a 64 x 64 matrix were obtained every minute for 30 min. Regions of interest were drawn around the periphery of the lungs and on the major airways. Clearance half-times (T 1/2 ) were calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was calculated on the first-minute image. There was no difference between the clearance rates of 99m Tc-DTPA before and after therapy for either the fluoxetine or the maprotiline group. After therapy, a significant decrease in PI was found in patients treated with fluoxetine (PI values before and after therapy: 0.53±0.03 and 0.49±0.05 respectively, P≤0.05). This finding might have been due to the induction of increased synaptic serotonin (5-HT) by fluoxetine, which acts by inhibiting the re-uptake of 5-HT on presynaptic membranes. Bronchoconstriction of small and medium airways may be caused by direct and indirect effects of 5-HT on smooth muscle contraction. (orig.)

  2. Technetium-99m DTPA inhalation scintigraphy in patients treated with fluoxetine and maprotiline: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, G.C.; Durak, H.; Oezdogan, Oe.; Sayit, E.; Degirmenci, B.; Derebek, E. [Dokuz Eyluel Univ., Izmir (Turkey). School of Medicine; Yemez, B.; Turhal, Ue. [Dept. of Psychiatry, Dokuz Eylul Univ. School of Medicine, Izmir (Turkey)

    2000-09-01

    Drug-metabolising enzymatic activities have been detected in tracheobronchiolar, bronchiolar and alveolar regions in the lungs. Induction of phospholipidosis by amine drugs such as clorphentermine has also been shown. This study aimed to investigate the effect of fluoxetine and maprotiline, which contain amine groups in their structure, on pulmonary epithelial membrane permeability. Twenty-seven patients (mean age 36{+-}12 years) with various psychiatric problems, of whom 17 were treated with fluoxetine and 10 with maprotiline, were included in this study. Technetium-99m diethylene triamine penta-acetic acid (DTPA) aerosol inhalation scintigraphy was performed before and after 4-6 weeks of therapy. Following the inhalation of 1480 MBq {sup 99m}Tc-DTPA for 3 min, lung images in a 64 x 64 matrix were obtained every minute for 30 min. Regions of interest were drawn around the periphery of the lungs and on the major airways. Clearance half-times (T{sub 1/2}) were calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was calculated on the first-minute image. There was no difference between the clearance rates of {sup 99m}Tc-DTPA before and after therapy for either the fluoxetine or the maprotiline group. After therapy, a significant decrease in PI was found in patients treated with fluoxetine (PI values before and after therapy: 0.53{+-}0.03 and 0.49{+-}0.05 respectively, P{<=}0.05). This finding might have been due to the induction of increased synaptic serotonin (5-HT) by fluoxetine, which acts by inhibiting the re-uptake of 5-HT on presynaptic membranes. Bronchoconstriction of small and medium airways may be caused by direct and indirect effects of 5-HT on smooth muscle contraction. (orig.)

  3. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    Science.gov (United States)

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  4. Triamide mercaptide (N/sub 3/S) ligands for Tc-99m as potential Tc-99m renal function agents

    International Nuclear Information System (INIS)

    Fritzberg, A.R.; Kasina, S.; Johnson, D.L.; Eshima, D.

    1985-01-01

    A number of diamide dimercaptide (N/sub 2/S/sub 2/) complexes of Tc-99m have shown potential as renal tubular function radiopharmaceuticals that could replace radioiodinated hippurate (OIH). Evaluation of such ligands suggested that maximum efficiency for tubular secretion and specificity resulted from addition of a carboxylate group. However, such derivatives resulted in chelate ring stereoisomers that were differently transported by the renal tubular system. The problem of stereoisomers was obviated by replacing one sulfur with an effectively planar amido nitrogen. Groups on the nitrogen then result in diastereomers only when an additional asymetric center is present. A series of triamide mercaptide compounds have been synthesized to evaluate this class as ligands for Tc-99m. One of the simplest of the series, mercaptoacetylglycylglycylglycine (MAG/sub 3/), formed a single Tc-99m product in high yield as determined by HPLC. Preliminary results with pmr and ms of the Tc-99 complex indicate a structure consistent with a 1:1 metal to ligand ratio and monooxo technetium group. Biological evaluation of Tc-99m MAG/sub 3/ showed high renal specificity and rate of excretion exceeding OIH in several species including humans. Members of the N/sub 3/S series studied include mercaptoacetylglycylglycyl-amino acids. In some cases with second asymmetric centers, two components were seen on HPLC. In mice several dianionic Tc-99m complexes were excreted faster than OIH, Tc-99m MAG/sub 2/-ala, -asn, and -gln. Trianionic Tc-99m MAG/sub 2/-asp and -glu were excreted more slowly, and Tc-99m MAG/sub 2/-phe showed hepatobiliary excretion. Triamide mercaptides represent a new ligand class for Tc-99m

  5. Preparation and biological evaluation of cyclopentadienyl-based 99mTc-complexes [(Cp-R)99mTc(CO)3] mimicking benzamides for malignant melanoma targeting

    International Nuclear Information System (INIS)

    Peindy N'Dongo, Harmel W.; Raposinho, Paula D.; Fernandes, Celia; Santos, Isabel; Can, Daniel; Schmutz, Paul; Spingler, Bernhard; Alberto, Roger

    2010-01-01

    The biological evaluation of half-sandwich 99m Tc-complexes that surrogate iodobenzamide with a high affinity for melanin tumor tissue is described. We have synthesized via retro Diels-Alder reaction two models of 99m Tc complexes which possess the piano stool [Cp 99m Tc(CO) 3 ] motif instead of a phenyl ring as in the original iodobenzamide 123 I-N-(N-benzylpiperidin-4-yl)-2-iodobenzamide (2-IBP) and N-(2-diethylaminoethyl)-4-iodobenzamide (BZA). Diels-Alder products - (HCp-CONHR) 2 (, R=2-diethylaminoethyl; , R=benzylpiperidin-4-yl) were prepared and reacted with fac-[ 99m Tc(H 2 O) 3 (CO) 3 )] + 1 in water to produce the corresponding 99m Tc complexes [() 99m Tc(CO) 3 )] and [() 99m Tc(CO) 3 )] . The structures of the 99m Tc complexes on the no-carrier-added level have been confirmed by chromatographic comparison with the corresponding rhenium complexes and , macroscopically characterized by IR, NMR, ESI-MS and X-ray crystallography for [triclinic, P-1, a=7.3518(1) A, b=8.0309(2) A, c=17.5536(3) A, α=99.1260(5) o , β=90.4215(14) o , γ=117.0187(11) o ]. The radioconjugate showed good in vitro stability. In murine melanoma B16F1 cells, significant cellular uptake (43.9% of the total applied activity) was attained after 4 h at 37 deg. C with about 50% of the cell-associated radioactivity being internalized in the cells (22% of the applied activity). Furthermore, in melanoma-bearing C57BL6 mice, tumor uptake values of 3.39±0.50 %ID g -1 and 3.21±0.26 %ID g -1 at 1 and 4 h postinjection, respectively, were observed indicating a good retention of in the tumor.

  6. Assessment of bacterial translocation in obstructive jaundice using Tc-99m Escherichia coli

    Directory of Open Access Journals (Sweden)

    Simone Odília Fernandes Diniz

    2005-10-01

    Full Text Available In obstructive jaundice, the passage of bacteria and endotoxins through the intestine wall to reach the systemic circulation is associated with septicemia, renal failure and pulmonary dysfunction. The aim of this work was to investigate bacterial translocation utilizing 99mTc-E.coli in an experimental model of obstructive jaundice. The levels of bilirubin in rats that were subjected to ligature of the bile duct were significantly increased when compared to control animals (p 0.05. The evaluation of the intestinal permeability using "per os" administration of 99mTc-DTPA showed 1.61 ± 0.57% and 1.39 ± 0.72% of radioactivity in the urine of the control and jaundice animals, respectively. The histological analysis of the distal wall of the ileum showed that the covering epithelium and the crypt were morphologically preserved in both groups. The seven-day period after the ligature of the bile duct may not have been long enough to promote modifications in intestinal wall to occur so as to permit the passage of Tc-99m E.coli.Na icterícia obstrutiva, a passagem de bactérias e endotoxinas através da parede intestinal alcançando a circulação sistêmica está associada com septicemia, falência renal e disfunção pulmonar. A proposta deste trabalho foi investigar a translocação bacteriana, empregando a Tc-99m E.coli, em um modelo experimental de icterícia obstrutiva. Os níveis de bilirrubina nos ratos que sofreram a ligadura do ducto biliar estavam significativamente aumentados quando comparados com os valores dos animais controles (p0,05. A avaliação da permeabilidade intestinal usando a administração "per os" de 99mTc-DTPA mostrou um percentual de eliminação deste radiofármaco na urina de 1,61±0,57 e 1,39±0,72 para os animais controles e ictéricos, respectivamente. A análise histológica da parede distal do íleo mostrou que tanto o epitélio de revestimento quanto as criptas apresentaram morfologicamente conservados em ambos os

  7. Preparation of 99mTc-HYNIC-PEG-liposomes for imaging of the focal sites infection

    International Nuclear Information System (INIS)

    Hong, Jun Pyo; Awh, Ok Doo; Kim, Hyun Suk; Lee, Eun Sook; Lee, Tae Sup; Choi, Tae Hyun; Choi, Chang Woon; Lim, Sang Moo

    2002-01-01

    A new linker, hydrazino nicotinamide (HYNIC), was recently introduced for labelling of liposome with 99m Tc. In this study we synthesized HYNIC derivatized PEG (polyethylene glycol)-liposomes radiolabeled with 99m Tc. In order to synthesize HYNIC-DSPE (distearoyl phosphatidyl ethanolamine) which is a crucial component for 99m Tc chelation, first of all succinimidyl 6-BOC-hydrazinopyridine-3-carboxylic acid was synthesized from 6-chloronicotinic acid by three sequential reactions. A DSPE derivative of succinimidyl 6-BOC-hydrazinopyridine-3-carboxylic acid was transformed into HYNIC-DSPE by HCI/dioxane. HYNIC-PEG-liposomes were prepared by hydration of the dried lipid mixture of EPC (egg phosphatidyl choline): PEG-DSPE : HYNIC-DSPE: cholesterol (1.85:0.15:0.07:1, molar ratio). The HYNIC-PEG-liposomes were labeled with 99m Tc in the presence of SnCl 2 ·2H 2 O (a reducing agent) and tricine (a colignad). To investigate the level of in vivo transchelation of 99m Tc in the liposomes, the 99m Tc-HYNIC-PEG-liposomes were incubated with a molar excess of DTPA, cysteine or glutathione solutions at 37 .deg. C for 24 hours. 6-BOC-hydrazinopyridine-3-carboxylic acid was synthesized with 77.3% overall yield. The HYNIC concentration in the PEG-coated liposome dispersion was 1.08 mM. In condition of considering the measured liposome size of 106 nm, the phospholipid concentration of 77.5 μmol/ ml and the liposomal particle number of 5.2x10 14 liposomes/ml, it is corresponded to approximate 1,250 nicotinyl hydrazine group per liposome in HYNIC-PEG-liposome. The removal of free 99m Tc was not necessary because the labeling efficiency were above 99%. The radiolabeled liposomes maintained 98%, 96% and 99%, respectively, of radioactivity after incubation with transchelators. The radiolabeled liposomes possessed above 90% of the radioactivity in serum. These results suggest that the HYNIC can be synthesized easily and applied in labelling of PEG-liposomes with 99m Tc

  8. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    Science.gov (United States)

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Assessment of bacterial translocation in obstructive jaundice using Tc-99m Escherichia coli

    Energy Technology Data Exchange (ETDEWEB)

    Diniz, Simone Odilia Fernandes; Nelson, David Lee [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Farmacia]. E-mail: simone@farmacia.ufmg.br; Barbosa, Alfredo Jose Afonso; Araujo, Ivana Durval; Machado, Leonardo Augusto da Silva [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Faculdade de Medicina; Bernardo Filho, Mario [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Dept. de Biofisica e Biometria

    2005-10-15

    In obstructive jaundice, the passage of bacteria and endotoxins through the intestine wall to reach the systemic circulation is associated with septicemia, renal failure and pulmonary dysfunction. The aim of this work was to investigate bacterial translocation utilizing {sup 99m} Tc-E.coli in an experimental model of obstructive jaundice. The levels of bilirubin in rats that were subjected to ligature of the bile duct were significantly increased when compared to control animals (p < 0.001). The biodistribution results did not show any translocation of {sup 99m} Tc-E.coli to the mesenteric lymphatic nodules, liver, spleen or lungs of the rats that suffered ligature of the bile duct (p > 0.05). The evaluation of the intestinal permeability using 'per os' administration of {sup 99m} Tc-DTPA showed 1.61 {+-} 0.57% and 1.39 {+-} 0.72% of radioactivity in the urine of the control and jaundice animals, respectively. The histological analysis of the distal wall of the ileum showed that the covering epithelium and the crypt were morphologically preserved in both groups. The seven-day period after the ligature of the bile duct may not have been long enough to promote modifications in intestinal wall to occur so as to permit the passage of Tc-99m E.coli. (author)

  10. Detection of diffuse glomerular lesions in rats: II. Comparison of indium-111 cationic small macromolecules with technetium-99m DTPA

    International Nuclear Information System (INIS)

    McAfee, J.G.; Thomas, F.D.; Subramanian, G.; Schneider, R.D.; Lyons, B.; Roskopf, M.; Zapf-Longo, C.; Whaley, D.

    1986-01-01

    Dextrans with average molecular weights of 5000, 10,000, and 17,500 and inulin were rendered cationic by amination with 2-bromoethylamine hydrobromide. After limited coupling with DTPA cyclic dianhydride, they were labeled with 111In. A good correlation was found between their early renal uptake quantitated by camera-computer techniques and their renal clearance from multiple plasma samples in rats with glomerular damage induced by puromycin aminonucleoside and controls. However, there was poor correlation between the early renal uptake of these agents and the clearance of simultaneously injected [/sup 99m/Tc]DTPA. The 2-hr organ distribution and urinary excretion of these agents were compared with the corresponding values of DTPA. The differences in clearance between rats with glomerular damage and controls were greater with aminated dextran (mol wt 5000) than with DTPA, confirming previous work with infusions of nonradioactive charged dextrans and neutral inulin. The cationic dextrans appear to reflect the presence or absence of the normal anionic charge of the glomerular membrane as well as changes in filtration rate. Aminated inulin did not differentiate between controls and rats with glomerular disease any better than DTPA, probably because the number of amino groups conjugated was insufficient to produce the charge effect

  11. Quality assurance of Mo-99/Tc-99m radionuclide generators

    Science.gov (United States)

    Uzunov, Nikolay; Yordanova, Galina; Salim, Seniha; Stancheva, Natalya; Mineva, Vanya; Meléndez-Alafort, Laura; Rosato, Antonio

    2018-03-01

    Gamma-ray spectrometry analyses of the radionuclide content of eluate from two Mo-99/Tc-99m radionuclide generators POLTECHNET have been performed. The relative activities of 99Mo 103Ru and 131I radioisotopes with respect to the activity of 99mTc at different time intervals after the primary pertechnetate elution of the generators have been analyzed. The relative activities of the isotopes were determined and compared to the radionuclidic purity requirements for 99mTc.

  12. Correlation between differential renal uptake of 99mTc-MAG3 and 99mTc-DMSA

    International Nuclear Information System (INIS)

    Obaldo, J.M.; Gruenwald, F.; Menzel, C.; Biersack, H.J.

    1994-01-01

    We reviewed the quantitative indices obtained from sequential 99m Tc-MAG3 and 99m Tc-DMSA imaging studies performed in 134 patients with a variety of renal disorders in order to determine the correlation between the measured differential renal function using these two agents. Overall correlation was high with r=.86 and the derived regression equation was R.F. DMSA =8.2+0.84 (R.F. MAG3 ), where F.F. is the relative function. Highly divergent values for differential function were obtained however in some subjects. Patients with renal obstructive disorders had a correlation coefficient of.81 which was lower than those with nonobstructive pathologies (r=.95). Although relative kidney function measured using 99m Tc-MAG3 and 99m Tc-DMSA correlate significantly, certain patients such as those with renal obstruction may necessitate quantitation using different renal parameters. (orig.) [de

  13. Some problems concerning /sup 99m/Tc-sulfur colloid stability in vivo

    International Nuclear Information System (INIS)

    Komarek, P.; Sup, I.; Krivsky, Z.

    1986-01-01

    On repeated examination of 60 patients with suspected transplanted kidney rejection using /sup 99m/Tc-sulfur colloid administration the urinary bladder appears on the scintigram in ten cases though no free pertechnetate-/sup 99m/Tc had been chromatographically determined before the administration. Therefore other causes of urine bladder visualization were considered. The fate of the radiocolloid in the body after its administration was studied by measuring the radioactivity of blood and plasma or by chromatographic analysis. A sixfold increase in /sup 99m/Tc activity in comparison with that determined chromatographically in the form of free pertechnetate-/sup 99m/Tc was found in the patients blood 45 min after administration. In normal animal experiments, /sup 99m/Tc was found in the rat blood and urine in the form of pertechnetate. (author)

  14. Biokinetics of osteotropic radiopharmaceuticals in metabolic osteopathies - comparison of 47Ca and sup(99m)Tc-MDP

    International Nuclear Information System (INIS)

    Knop, J.; Montz, R.

    1983-01-01

    Plasma clearance and osseous accumulation rates of sup(99m)Tc methylene diphosphonate (MDP) in the lumbar spine were measured in 11 patients with osteoporosis (OP), 7 patients with hyperparathyroidism (HPT), 4 patients with osteomalacia (OM) and in 3 patients (N) who were studied to exclude metabolic bone disease. The findings in 19 patients were compared with the results of 47 Ca kinetics. The plasma elimination of sup(99m)Tc-MDP during the first hour after application was normal in almost all the patients. The sup(99m)Tc-MDP accumulation rates in the lumbar spine were raised in patients with HPT and OM (p 0,05). 47 Ca kinetics were disturbed in most of the patients with metabolic bone disease, with minimal deviations in OP. The comparison of sup(99m)Tc-MDP accumulation rates with the results of 47 Ca kinetics revealed significant correlations with exchangeable bone and soft tissue calcium. The correlations with total calcium turnover and calcium accretion were poor. Only half of the patients had equal results of sup(99m)Tc-MDP accumulation rates and bone calcium accretion rates. It is concluded that the sup(99m)Tc-MDP uptake by bone is an index of bone metabolism presumably of the organic matrix, whereas 47 Ca kinetics represent the mineral metabolism of bone. (orig.) [de

  15. The Comparative Study of the Measurement of Serum Cystatin C and 99mTc-DTPA for the Measurement of Glomerular Filtration Rate (GFR) in Type 2 Diabetic Nephropathy

    International Nuclear Information System (INIS)

    Kong Linghua; Wu Junyuan; Gao Bin; Wang Xueqin; Gu Kaikai

    2010-01-01

    To explore the clinical value between measurement of serum cystatin C (Cys C) and determination of plasma with 99m Tc-DTPA glomerular filtration rate (GFR) clearance for type 2 diabetes (T2DM) in early detection of renal damage, the serum cystatin C levels in 87 patients with type 2 diabetes were determined by immune turbidimetry Cys C. The patients were also carried out dynamic imaging to measure renal GFR. The result showed that the serum levels of Cys C in patients with Type 2 diabetic was 1.68 ± 0.52 mg / L, the normal group was 0.72±0.26 mg/L; The GFR in patients with T2DM was 93.8 ± 30.2 ml/min/1.73m 2 , the control group was 107.48±15.23 ml/min/1.73m 2 , there was significant difference between patients and controls (P 99m Tc-DTPA renal dynamic imaging. The serum Cys C could reflect the damage in early diabetic patients. The method is simple, accurate and easy to spread. The renal dynamic imaging method of GFR determination is slightly complex and requires specialized equipment. It can reflect the sub-renal function. The combined measurement of serum Cys C and GFR are very important in the early detection of type 2 diabetic patients with early renal function. (authors)

  16. Extraosseous localization of sup(99m)Tc-diphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Nakama, M; Sugawara, T; Furuse, M; Shibuya, K; Watanabe, T [Jichi Medical School, Tochigi (Japan)

    1977-10-01

    Many different types of extraosseous lesions have been reported using /sup 99m/Tc-phosphate bone scanning agents. Abnormal extraosseous localization was observed in 30 cases among the patients referred for bone scanning with /sup 99/Tc-diphosphonate. The lesions associated with extraosseous accumulation are as follows: carcinomatous pleurisy 14 cases; lung cancer 3; brain metastasis 3; digestive tract cancer 4; skin and contralateral breast metastasis from breast cancer 1; respectively; and other benign disease 4, e.i. meningioma, angiofibroma of the nasopharynx, and myositis ossificans. Eighty-seven per cent of the extra-osseous accumulations of /sup 99m/Tc-diphosphonate were malignant, and preferential accumulation for adenocarcinoma was observed in comparison with other pathological groups. Among those patients, 7 cases of marked extraosseous localizations were demonstrated in this report. The mechanisms for the localization in extraosseous lesions are discussed.

  17. 99mTc bone scanning agents preparation and chemical analysis of Tc(Sn)pyrophosphate, Tc(Sn)MDP and Tc(Sn)HMDP

    International Nuclear Information System (INIS)

    Kroesbergen, J.

    1986-01-01

    This thesis describes a comparison of the preparation, composition and properties of three bone scanning agents: 99m Tc(Sn)pyrophosphate, 99m Tc(Sn)MDP and 99m Tc(Sn)HMDP. This study has been performed for two reasons: First to investigate the preparation and composition of the radiopharmaceuticals as a function of experimental conditions. Together with previously reported results for 99m Tc(Sn)EHDP, obtained in a similar way, this enables to use well-defined preparations of the bone scanning agents. Secondly to gain an insight in the mechanism in which the agents behave 'in vivo'. Because the 'in vivo' process is too complicated to study directly, it seemed more appropriate to perform 'in vitro' investigations as simplifications of the 'in vivo' situation. 304 refs.; 26 figs.; 31 tabs

  18. Determination of radiochemical purity and pharmacokinetic parameters of sup(99m)Tc-sulphur colloid and sup(99m)Tc-tin colloid

    International Nuclear Information System (INIS)

    Jovanovic, V.; Konstantinovska, D.; Milivojevic, K.; Bzenic, J.

    1981-01-01

    Labelling yield and radiochemical purity, higher than 95%, of sup(99m)Tc-colloid preparations were determined by using the paper chromatography method. Less than 3% of labelled citric acid, added to the preparation as a buffer solution, has been found in sup(99m)Tc-sulphur colloid. High radiochemical purity and optimum size of colloid particles has also been proved by biodistribution studies on experimental animals. The analysis performed has shown that more than 50% of sup(99m)Tc-colloid preparations excreted by urine is sup(99m)TcO - , the remaining past 50% being protein bound sup(99m)Tc. Biological half-time of excretion of the fast phase is the same for both preparations, i.e. 10 min, while for the slow component it is 120 min in sup(99m)Tc-S-colloid and 160 min in sup(99m)Tc-Sn colloid. (orig.) [de

  19. Comparative study of uptake and washout of 99mTcN(NOEt)2 with 99mTc-MIBI in human cervical carcinoma cell lines

    International Nuclear Information System (INIS)

    Xing Shi'an; Zhang Yongxue; An Rui

    2002-01-01

    Objective: to investigate the cellular kinetics of bis (N-ethoxy-N-ethyl dithiocarbamato) nitrido 99m Tc(V) [ 99m TcN (NOEt) 2 ] in human cervical carcinoma cell line Hela and to compare it with that of 99m Tc hexakis-2- methoxyisobutyl isonitrile ( 99m Tc-MIBI), and hence to define the possible clinical value of 99m TcN(NOEt) 2 in tumor imaging. Methods: Using radionuclide tracer technique, 99m TcN(NOEt) 2 and 99m Tc-MIBI were incubated with human cervical carcinoma cell lines Hela at 37 degree C and at 22 degree C respectively. At several incubation times, the uptake and washout characteristics of the radiotracers in human cervical carcinoma cell line Hela were investigated and compared. Results: The maximum uptake of 99m TcN(NOEt) 2 in Hela was 46.15% and that of 99m Tc-MIBI was 12.6% (P 99m TcN(NOEt) 2 after 5 min incubation in human cervical carcinoma cell line Hela was 65% of the total uptake, while that of 99m Tc-MIBI was 50% of the total uptake (P 99m TcN(NOEt) 2 was retained in the Hela cells at one hour while 56.67% of 99m Tc-MIBI was retained (P 99m Tc-MIBI, the cellular kinetics of 99m TcN(NOEt) 2 was not temperature-dependent (the cellular kinetics is similar at 37 degree C and at 22 degree C, P>0.05). Conclusions: In vitro data suggest that 99m TcN(NOEt) 2 may be a better tracer than 99m Tc-MIBI in tumor imaging and 99m TcN(NOEt) 2 has potential application in clinical use

  20. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26

    International Nuclear Information System (INIS)

    Watanabe, N.; Gunma Univ. School of Medicine; Oriuchi, N.; Inoue, T.; Sugiyama, S.; Kuroki, M.; Matsuoka, Y.; Tanada, S.; Murata, H.; Sasaki, Y.

    1999-01-01

    Aim: The purpose of this study was to assess the potential for radioimmunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. Methods: The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. Results: The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 ± 0.95% vs. 11.9 ± 0.55% at 100 ng/mL of soluble CEA, 83.5 ± 2.84% vs. 54.0 ± 2.54% at 10 7 of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 ± 3.50% ID/g vs. 14.4 ± 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 ± 2.10% ID/g vs. 8.01 ± 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 ± 1.70% ID/g vs. 8.10 ± 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). Conclusion: 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer. (orig.) [de

  1. Comparison of 99mTc-HYNIC-TOC and HYNIC-TATE octreotide scintigraphy with FDG PET and 99mTc-MIBI in local recurrent or distant metastatic thyroid cancers.

    Science.gov (United States)

    Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii

    2013-05-01

    There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.

  2. sup(99m)Tc-Ethylenediamine-N, N-diacetic acid

    International Nuclear Information System (INIS)

    Imoto, Takeshi

    1984-01-01

    sup(99m)Tc-Ethylenediamine-N, N-Diacetic Acid (sup(99m)Tc-EDDA), a compound having affinity for tumors was evaluated, and the results were as follows. 1) sup(99m)Tc-EDDA accumulated in experimentary-induced tumors. The tumor/tissue ratio (%g/dose) of sup(99m)Tc-EDDA was greater than that of 67 Ga-citrate, especially with Ehrlich ascites tumors. 2) sup(99m)Tc-EDDA accumulated mainly in the nuclear components of tumor cells. 3) No acute toxic effects of EDDA were observed in mice, rabbits or in volunteers. 4) The sup(99m)Tc-EDDA image was positive in 72 % of clinical examinations of lung cancer. The sup(99m)Tc-EDDA did not accumulate in the liver, and this suggests that tumor near the liver may be more easily detected with sup(99m)Tc-EDDA than with 67 Ga-citrate. 5) In some cases sup(99m)Tc-EDDA accumulated in mammary glands (nipples) and in pleural effusions (pleuritis), though the mechanism of which was obscure. 6) sup(99m)Tc-EDDA is a good agent for detecting malignant tumors. (author)

  3. Clinical evaluation of sup(99m)Tc-(Sn)-PI (sup(99m)Tc-(Sn)-pyridoxylidene isoleucine) in the various hepatobiliary disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, S; Iio, M; Yamada, H; Murata, H; Chiba, K [Tokyo Metropolitan Geriatric Medical Center (Japan)

    1978-12-01

    The purpose of this study is to evaluate the hepatobiliary scanning using sup(99m)Tc-(Sn)-PI in clinical diagnosis of various hepatobiliary disorders. Nineteen patients were scanned with sup(99m)Tc-(Sn)-PI. The results were as follows: 1) The stability of sup(99m)Tc-(Sn)-PI examined by paper chromatography using saline as a solvent showed satisfied result at scanning time. sup(99m)Tc-(Sn)-PI in the blood was assumed to be bound to serum proteins immediately after injection. sup(99m)Tc-(Sn)-PI in the urine was assumed to keep the form of sup(99m)Tc-(Sn)-PI. 2) The appearance times of kidney, liver, bile duct, gallbladder, and intestine in the normal case were 5, 5, 10 and 15 minutes respectively after injection. The peak times of hepatogram in the normal case, drug induced hepatitis and obstructive jaundice were 12, 15 and 18 minutes respectively after injection. The images obtained by sup(99m)Tc-(Sn)-PI was superior to the images obtained by /sup 131/I-BSP. 3) The blood clearance and urinary excretion rate of sup(99m)Tc-(Sn)-PI also provided us clinical usefulness. 4) The scanning of Dubin-Johnson syndrome of sup(99m)Tc-(Sn)-PI showed almost normal hepatobiliary image similar to the sequential scan by /sup 131/I-RB as was reported previously by authors. In conclusion, the hepatobiliary scan using sup(99m)Tc-(Sn)-PI provided clear hepatobiliary images. Other parameters such as blood clearance, urinary excretion rate and diameter of choledochus were also favorable. By combining it with sup(99m)Tc-HIDA a differential diagnosis of congenital jaundice is also expected.

  4. Clinical evaluation of sup(99m)Tc-(Sn)-PI [sup(99m)Tc-(Sn)-pyridoxylidene isoleucine] in the various hepatobiliary disorders

    International Nuclear Information System (INIS)

    Kawaguchi, Schinichiro; Iio, Masahiro; Yamada, Hideo; Murata, Hajime; Chiba, Kazuo

    1978-01-01

    The purpose of this study is to evaluate the hepatobiliary scanning using sup(99m)Tc-(Sn)-PI in clinical diagnosis of various hepatobiliary disorders. Nineteen patients were scanned with sup(99m)Tc-(Sn)-PI. The results were as follows: 1) The stability of sup(99m)Tc-(Sn)-PI examined by paper chromatography using saline as a solvent showed satisfied result at scanning time. sup(99m)Tc-(Sn)-PI in the blood was assumed to be bound to serum proteins immediately after injection. sup(99m)Tc-(Sn)-PI in the urine was assumed to keep the form of sup(99m)Tc-(Sn)-PI. 2) The appearance times of kidney, liver, bile duct, gallbladder, and intestine in the normal case were 5, 5, 10 and 15 minutes respectively after injection. The peak times of hepatogram in the normal case, drug induced hepatitis and obstructive jaundice were 12, 15 and 18 minutes respectively after injection. The images obtained by sup(99m)Tc-(Sn)-PI was superior to the images obtained by 131 I-BSP. 3) The blood clearance and urinary excretion rate of sup(99m)Tc-(Sn)-PI also provided us clinical usefulness. 4) The scanning of Dubin-Johnson syndrome of sup(99m)Tc-(Sn)-PI showed almost normal hepatobiliary image similar to the sequential scan by 131 I-RB as was reported previously by authors. In conclusion, the hepatobiliary scan using sup(99m)Tc-(Sn)-PI provided clear hepatobiliary images. Other parameters such as blood clearance, urinary excretion rate and diameter of choledochus were also favorable. By combining it with sup(99m)Tc-HIDA a differential diagnosis of congenital jaundice is also expected. (author)

  5. 99m Tc- la bed somatostatin analogs for imaging somatostatin-receptor-positive tumors

    International Nuclear Information System (INIS)

    Gandomkar, M.; Najafi, R.; Shafiei, A.; Sadat Ebrahimi, E.; Babaie, M.H.; Rabani, M.

    2002-01-01

    Over the least few years, 111 In-DTPA- Octreotide has found widespread clinical applicability, especially in oncology. However limitation, especially concerning availability, imaging properties, and costs, remain and have stimulated research on radiolabeling with many alternative radionuclides. The purpose of this investigation was to labeling somatostatin analogs with 99 m Tc and evaluate their suitability as an agents for in vivo use. Octreotide and Tyr-3-Octreotide were labeled by 99 mTc with direct and indirect methods. Sodium ascorbate and sodium dithionite were used for reduction of cystine bridge and HYNIC was used as bifunctional agents and different co ligands used for labeling by 99 mTc. Yield of labeling, purity, stability, internalisation, binding affinity and biodistribution of peptide conjugates were studied. Direct labeling of octreotide was simple, rapid, efficient and yield was good (%60). K d for binding affinity as high (10 -9 ) but stability was low. Labeling for HYNIC-Tyr-Octreotide had a high yield (>%90), good stability, internalisation and biodistribution. with more experimental work and some improve this peptide-based radiopharmaceuticals can be employed in all nuclear medicine centers as a useful agent for imaging of tumors

  6. Different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains: analysis by statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I.Y. [Dept. of Nuclear Medicine, Inha University College of Medicine, Incheon (Korea); Lee, J.S.; Lee, D.S. [Dept. of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea); Rha, J.H.; Lee, I.K.; Ha, C.K. [Dept. of Neurology, Inha University College of Medicine, Incheon (Korea)

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer ({sup 99m}Tc-ECD) and technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62{+-}12 years) using {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either {sup 99m}Tc-ECD or {sup 99m}Tc-HMPAO SPET images. SPM analysis revealed significantly different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains. On the {sup 99m}Tc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the {sup 99m}Tc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with {sup 99m}Tc-ECD and

  7. Bioavailability of {sup 99m}Tc-paclitaxel-glucuronide ({sup 99m}Tc-PAC-G)

    Energy Technology Data Exchange (ETDEWEB)

    Biber Muftuler, F.Z.; Demir, I.; Uenack, P.; Ichedef, C.; Yurt Kilcar, A. [Ege Univ., Izmir (Turkey). Dept. of Nuclear Applications

    2011-07-01

    An antitumor agent paclitaxel (PAC) has been proved to be efficient in the treatment of breast and ovarian cancer. Glucuronic acid-derived paclitaxel compound (paclitaxel-glucuronide (PAC-G)) was enzymatically synthesized using microsome preparate separated from rat livers. The biodistribution mechanism of PAC-G in healthy female Albino Wistar rats has been investigated. The expected structure is confirmed according to LC/MS results, and the possible attachment is to C2-hydroxyl group. PAC-G was labeled with {sup 99m}Tc and the radiochemical yield of radiolabeled compound ({sup 99m}Tc-PAC-G) was 98.0 {+-} 02.74% (n=9). The range of the breast/blood and breast/muscle ratios is approximately between 3 and 35 in 240 min. All these experimental studies indicate that {sup 99m}Tc-PAC-G may potentially be used in breast tissue as an imaging agent. (orig.)

  8. Development of 99Mo/99mTc Generator System for Production of Medical Radionuclide 99mTc using a Neutron-activated 99Mo and Zirconium Based Material (ZBM as its Adsorbent

    Directory of Open Access Journals (Sweden)

    I. Saptiama

    2016-12-01

    Full Text Available Molybdenum produced from fission of U-235 is the most desirable precursor for 99Mo/99mTc generator system as it is non-carrier added and has high specific activity. However, in the last decade there has been short supply of 99Mo due to several constrains. Therefore, there have been many works performed for development of 99Mo/99mTc generator system using 99Mo which is not produced from either LEU or HEU. This report deals with development of 99Mo/99mTc generator system where zirconium-based material (ZBM is used as adsorbent of neutron-activated 99Mo. The system was prepared by firstly irradiating natural Mo in the G. A. Siwabessy reactor to produce neutron-activated 99Mo. The target was dissolved in NaOH 4N and then neutralized with 12 M HCl. The 99Mo solution was then mixed with a certain amount of ZBM followed by heating at 90°C for three hours to allow the 99Mo adsorbed on ZBM. The 99Mo-ZBM (9.36 GBq of 99Mo was Mo/ 4.2 g ZBM was packed on a fritz-glass column. This column was then fitted serially with an alumina column for trapping 99Mo breakthrough. The columns were then eluted daily with saline solution for up to one week. The yield of 99mTc was found to be between 53.7 – 74% (n= 5. All 99mTc eluates were clear solutions with pH of 5. Breakthrough of 99Mo in 99mTc eluates was found to be 0.031 ± 0.019 μCi 99Mo/ mCi 99mTc (n= 5 which was less than the maximum activity of 99Mo allowed in 99mTc solution ( 99%. Radiolabeling of this 99mTc towards methylene diphosphonate (MDP kit gave a radiolabelling efficiency of 99%. In summary, a new 99Mo/99mTc generator system that used neutron-activated 99Mo and ZBM as its adsorbent has been successfully prepared. The 99mTc produced from this new 99Mo/99mTc generator system attained the quality of 99mTc required for medical purposes.

  9. Hepato-biliary scan using sup(99m)Tc-pyridoxylidene isoleucine (sup(99m)Tc-PI) and its clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S; Watahiki, H; Takeda, I; Kitamura, K; Ichikawa, H [Ogaki Municipal Hospital, Gifu (Japan)

    1978-05-01

    The hepato-biliary scan with sup(99m)Tc-pyridoxylidene Isoleucine (sup(99m)Tc-PI) was able to demonstrate the biliary system much more clearly than that using usual radiopharmaceuticals such as /sup 131/I-BSP of /sup 131/I-Rose Bengal. The hepato-biliary scan with sup(99m)Tc-PI demonstrated the hepatobiliary system more clearly than DIC in 47.6% of all cases studied. Especially the demonstration of changes of intra-hepatic biliary tree in cases with intra-hepatic gall stone and cholangiocarcinoma was quite superior to DIC, although there was somewhat difficulty in getting information about the right hepatic duct. For the diagnosis of gall stone in the gall bladder, DIC was more suitable than sup(99m)Tc-PI hepatobiliary scan. The sup(99m)Tc-PI hepato-biliary scan was able to demonstrate the biliary system even in cases having moderate jaundice, in which cases DIC could not demonstrate the biliary system. This sup(99m)Tc-PI hepato-biliary scan was proved to be useful in determing a certain cause of defects shown on the conventional liver scan. No side effect was noticed in this series of the study.

  10. Synthesis, radiochromatography and biodistribution of sup(99m)Tc-dimethylphosphinoethane (DMPE) complexes

    International Nuclear Information System (INIS)

    Angelberger, P.; Wagner-Loeffler, M.; Hruby, E.; Dudczak, R.

    1985-01-01

    The title complex were prepared from no-carrier-added sup(99m)Tc-TcOsub(4)sup(-) and the air-sensitive reducing ligand DMPE under argon in ethanol-water. At acidic pH [Tc(III)Clsub(2) dmpesub(2)]sup(+) was formed, while alkaline pH led to the formation of 95% yield in less than 1 hour, otherwise the [Tc(V)Osub(2)dmpesub(2)]sup(+) intermediate was present. Electrophoresis demonstrated the unit positive charge and reversed-phase ion-pair HPLC provided separation and identification of sup(99m)Tc-products by direct comparison with known sup(99m)Tc-complexes. In rats the sup(99m)Tc-complexes were excrated by kidneys and liver and reached high heart/blood but only low heart/lung and heart/liver ratios. In dogs satisfactory myocardial scintigrams were obtained in spite of high liver activity. (author)

  11. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    Science.gov (United States)

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  12. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys

    International Nuclear Information System (INIS)

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J.; Maecke, Helmut R.

    2004-01-01

    The aim of this study was to compare renal handling and distribution of 99m Tc-octreotide and 99m Tc-EDDA/HYNIC-Tyr 3 -octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of 99m Tc-octreotide was three times lower than that of 99m Tc-EDDA/HYNIC-TOC. The predominant renal excretion of 99m Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that 99m Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of 99m Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation

  13. Csintigraphic imaging of experimental cardiomyopathy in dogs using /sup 99m/Tc-hexylidene aminodiphosphonate (/sup 99m/Tc-AHDP)

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Vizda, J; Kafka, P; Kubicek, J; Mazurova, Y; Palicka, V; Grossmann, V

    1987-11-01

    Scintiscanning of the myocardium using /sup 99m/Tc-AHDP (hexylidene aminodiphosphonate) was performed in 12 dogs with experimental cardiomyopathy, induced by a large intravenous dose of theophylline and adrenaline. A marked positivity of the scan was determined in animals with 4 and 24 hours-old lesions. The scans proved to be negative after 7 days. The scintigraphic examinations yielded results which were in agreement with the plasma level of creatine kinase, a comparison with histological examination revealed that the maximum accumulation of the radiopharmaceutical occurred at the time the myocardium damage reached the stage of myocytolysis. /sup 99m/Tc-AHDP is therefore suitable for the detection of mild myocardium damage at its early stages. (author). 1 fig., 1 tab., 20 refs.

  14. Evaluation of 99mTc labelled human immunoglobulin (99mTc-HIG) in infection/inflammatory foci imaging. Final report for the period 15 December 1996 - 15 August 1997

    International Nuclear Information System (INIS)

    Shimpi, H.H.

    1997-10-01

    The aim of the study was to investigate whether the labelling efficiency biodistribution and inflammatory focus detection are dependent on the source of the human immunoglobulin G (HIG) and the chelating agent used in the labelling of the HIG with 99mTc. Three forms of immunoglobulins; Gamma venin P, Intraglobulin F and Sandoglobulin were used in this study. Reduction of HIG was done by 2-mercaptoethanol at molar ratio 1000:1, with 30 minutes reaction time at room temperature. The reduced HIG was then purified, membrane filtered aliquoted and lyophilised. Lyophilised HIG was dissolved in sterile normal saline and chelated with one of the following ligands Sn-MDP, SN PYP, Sn DTPA, SN-GH and Sn-citrate and then added 99m Tc04 for labelling. The radiochemical purity of the labelled compound was 90%. The biodistribution studies were done wistar rats where in the experimental groups were sacrifised at 3,5 and 24 hours following 99mTc HIG injection intravenously. Imaging studies were carried out in rabbits. Sterile inflammatory lesions were produced in the thigh muscle of these animals by injection of turpentine oil and the contralateral thigh muscle served as-controls. The results showed that there was no significant difference in biodistribution and inflammatory focus uptake of 9gmTc HIG with respect to the sources of HIG. There was favourable biodistribution characteristics when the ligands used were Sn MDP and Sn-Citrate

  15. Measurement of glomerular filtration rate using technetium-99m-DTPA and the gamma camera: A comparison of methods

    International Nuclear Information System (INIS)

    Russell, C.D.; Bischoff, P.G.; Kontzen, F.; Rowell, K.L.; Yester, M.V.; Lloyd, L.K.; Tauxe, W.N.; Dubovsky, E.V.

    1984-01-01

    A variety of methods has been proposed to estimate glomerular filtration rate (GFR) from renal uptake of Tc-99m-DTPA using a gamma camera. To compare alternative methods, the authors have calculated GFR in several different ways from measurements in 33 patients, and compared the results with an independent GFR measurement based on 8-point plasma clearance of Yb-169-DTPA. The best agreement was obtained using an algorithm that has not been described previously. This was a modification of a method used previously in which correction was made for overlap of kidneys by liver and spleen. The correlation coefficient was 0.958 and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with correlation coefficient 0.866 and residual standard deviation 21.1 ml/min. The accuracy of these methods was comparable to that reported for the creatinine clearance, the most commonly used estimate of GFR in current clinical practice

  16. Tc-99m DTPA perfusion scintigraphy and color coded duplex sonography in the evaluation of minimal renal allograft perfusion

    International Nuclear Information System (INIS)

    Bair, H.J.; Platsch, G.; Wolf, F.; Guenter, E.; Becker, D.; Rupprecht, H.; Neumayer, H.H.

    1997-01-01

    Aim: The clinical impact of perfusion scintigraphy versus color coded Duplex sonography was evaluated, with respect to their potential in assessing minimal allograft perfusion in vitally threatened kidney transplants, i.e. oligoanuric allografts suspected to have either severe rejection or thrombosis of the renal vein or artery. Methods: From July 1990 to August 1994 the grafts of 15 out of a total of 315 patients were vitally threatened. Technetium-99m DTPA scintigraphy and color coded Duplex sonography were performed in all patients. For scintigraphic evaluation of transplant perfusion analog scans up to 60 min postinjection, and time-activity curves over the first 60 sec after injection of 370-440 MBq Tc-99m diethylenetriaminepentaacetate acid (DTPA) were used and classified by a perfusion score, the time between renal and iliac artery peaks (TDiff) and the washout of the renogram curve. Additionally, evaluation of excretion function and assessment of vascular or urinary leaks were performed. By color coded Duplex sonography the perfusion in all sections of the graft as well as the vascular anastomoses were examined and the maximal blood flow velocity (Vmax) and the resistive index (RI) in the renal artery were determined by means of the pulsed Doppler device. Pathologic-anatomical diagnosis was achieved by either biopsy or post-explant histology in all grafts. Results: Scintigraphy and color coded Duplex sonography could reliably differentiate minimal (8/15) and not perfused (7/15) renal allografts. The results were confirmed either by angiography in digital subtraction technique (DSA) or the clinical follow up. Conclusion: In summary, perfusion scintigraphy and color coded Duplex sonography are comparable modalities to assess kidney graft perfusion. In clinical practice scintigraphy and colorcoded Doppler sonography can replace digital subtraction angiography in the evaluation of minimal allograft perfusion. (orig.) [de

  17. Sup(99m)Tc compounds for diagnostic purposes

    International Nuclear Information System (INIS)

    Cifka, J.; Budsky, F.

    1980-01-01

    The applications of sup(99m)Tc in nuclear medicine are discussed, such as sodium pertechnetate in thyroid and brain scintigraphy, complex compounds in lungs and liver diao.nosis. Technetium generators are classified according to the method of separating sup(99m)Tc from 99 Mo. Adsorption generators are used, molybdate-99 is adsorbed on an Al 2 O 3 -packed column while pertechnetate-99m is eluted with 0.9% NaCl solution. Also used is continuous pertechnetate-99m extraction with methyl ethyl ketone from 0.5 M potassium molybdate and 2.5 M of potassium carbonate. The manufacture is described of kits for sup(99m)Tc radiopharmaceuticals preparation, eg., Diagos I, a gluconate complex, a lyophilisate for sup(99m)Tc-sodium pyrophosphate injections, a diagnostic kit for lung scintiscanning. (H.S.)

  18. Comparison study among methodologies of planar chromatography for radiochemical control of technetium-99m; Estudo comparativo entre metodologias de cromatografia planar para controle radioquimico de radiofarmacos de tecnecio-99m

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Elisiane de Godoy

    2012-07-01

    Radiopharmaceuticals are substances that have radioisotopes in their composition. About 95% of the procedures performed in nuclear medicine use radiopharmaceuticals with diagnostic purposes, and the Lyophilized Reagents (LR) labeled with Technetium-99m ({sup 99}mTc), obtained from {sup 99}Mo/{sup 99}mTc generator, are the most one used. Quality Control represents the set of assays to be performed to assure that the product is adequate to its purpose. An important feature to be evaluated in {sup 99m}Tc radiopharmaceuticals is the radiochemical purity (% RqP) to quantify free pertechnetate ({sup 99}mTcO{sub 4}{sup -}) and technetium colloidal (99mTcO{sub 2}) mainly by paper chromatography (PC), thin layer (TLC) and High Performance Liquid Chromatography (HPLC). The objective of this work was to perform the comparison among the radiochemical control methodologies of LR labeled with {sup 99m}Tc, described in the United States Pharmacopoeia (USP) and European Pharmacopoeia (EP) and those used by IPEN. {sup 99m}TcO{sub 4}{sup -} eluate and DISIDA, DMSA, DTPA, EC, ECD, GHA, MIBI, MDP, PIRO, SAH and Sn Coloidal LR were provided by IPEN-CNEN/SP. TLC-cellulose, TLC-SG.TLC-SG reverse phase, HPTLC-cellulose, HPTLC-SG (Merck) and ITLC-SG (Pall Corporation), W1MM, W3MM, W17M e W31ET (Whatman) chromatographic plates were used. The measurement of the radioactivity was done in a Perkin Elmer Cobra D-5002 gamma counter. LR were labeled to obtain 55,0 MBq mL{sup 1} (1,5 mCi mL{sup 1}) of final radioactive concentration. The %{sup 99m}TcO{sub 4}{sup -}, %{sup 99m}TcO{sub 2} and % RqP were determined up to 4 hour labeling. From 11 LR, only EC and GHA have no radiochemical control methods in USP and EP. In USP and/or EP, DTPA, MDP, PIRO, SAH and Sn Coloidal methods use ITLC-SG; IPEN uses this chromatography plate in DISIDA, EC, ECD, GHA, PIRO, MIBI and SAH. As ITLC-SG had been out of production (recommended in 40, 70 and 41% of the USP, EP and IPEN methodologies, respectively), it was

  19. Influence of different chelators (HYNIC, MAG3 and DTPA) on tumor cell accumulation and mouse biodistribution of technetium-99m labeled to antisense DNA

    International Nuclear Information System (INIS)

    Zhang, Y.M.; Liu, N.; Zhu, Z.-H.; Rusckowski, M.; Hnatowich, D.J.

    2000-01-01

    We have shown recently that cell accumulation in culture of antisense DNA is strongly influenced by the presence of a 99m Tc-MAG 3 group for radiolabeling. We have now compared the in vitro and mouse in vivo behavior of 99m Tc when radiolabeled to one antisense phosphorothioate DNA by three different methods. The 18-mer antisense DNA against the RIα subunit of PKA was conjugated via a primary amine on the 5'-end with the NHS esters of HYNIC and MAG 3 and by the cyclic anhydride of DTPA. Surface plasmon resonance measurements revealed that the association rate constant for hybridization was unchanged for all three chelators as compared with that of the native DNA. Size exclusion HPLC showed rapid and quantitative protein binding for all three chelators upon incubation of labeled DNAs in 37 C serum and cell culture medium. However, in each case, radiolabeled and intact oligonucleotide was still detectable after 24 h. Cellular uptake was tested in an RIα mRNA-positive cancer cell line. The order of cellular accumulation of 99m Tc was DTPA>HYNIC(tricine)>MAG 3 , with the differences increasing with time between 4 and 24 h. The rate of 99m Tc egress from cells was found to be MAG 3 >HYNIC>DTPA, which may explain the order of cellular accumulation. The biodistribution in normal mice was heavily influenced by the labeling method and followed a pattern similar to that seen previously by us for peptides labeled with the same chelators. In conclusion, although these studies concerned only one antisense DNA in one cell line, the results suggest that the success of antisense imaging may depend, in part, on the method of radiolabeling. (orig.)

  20. Comparison between high-resolution computed tomography and 99mTc-technegas SPECT pulmonary emphysema

    International Nuclear Information System (INIS)

    Nakano, Satoru; Satoh, Katashi; Takahashi, Kazue

    1996-01-01

    Scintigraphy with 99m Tc-technegas was recently introduced for clinical imaging of lung ventilation. This method has been found to be useful in emergencies, to be more suitable for single photon emission computed tomography (SPECT) than other agents used in ventilation scintigraphy, and could reveal abnormalities in ventilation more easily than high resolution computed tomography (HRCT) in pulmonary emphysema. We compared 99m Tc-technegas SPECT with HRCT in six regions: the right upper, middle, and lower lobes, the left upper lobe, the lingula, and the left lower lobe, in 15 patients with pulmonary emphysema. Patients with centrilobular emphysema tended to show stronger changes in upper lobes than in lower lobes on both 99m Tc-technegas SPECT and HRCT. Some regions showed no change on HRCT but various changes on 99m Tc-SPECT. Patients with panlobular emphysema showed severe changes on 99m Tc-SPECT in lower lung fields in which well-demarcated areas of low attenuation were not seen on HRCT. We conclude that 99m Tc-SPECT is useful for detecting early changes and panlobular changes in pulmonary emphysema. (author)

  1. Technetium-99m tetrofosmin imaging in thyroid diseases: comparison with Tc-99m-pertechnetate, thallium-201 and Tc-99m-methoxyisobutylisonitrile scans

    International Nuclear Information System (INIS)

    Klain, M.; Cuocolo, A.; Marzano, L.; Lombardi, G.; Salvatore, M.; Univ. di Napoli

    1996-01-01

    In this study, tetrofosmin whole-body scintigraphy was performed in 35 patients with evidence of thyroid diseases. All patients underwent laboratory evaluation of thyroid function as well as 99m Tc pertechnetate scan, thallium-201 99m Tc-methoxyisobutylisonitrile (MIBI) whole-body studies. Thyroid images were semi-quantitatively analysed by a 4-point score: 0=no significant uptake; 1=uptake increased but inferior to normal thyroid tissue; 2=uptake equal to normal thyroid tissue; 3=uptake superior to normal thyroid tissue. A total of 41 thyroid nodules were detected, of which 15 were goitre nodules, 13 adenomas and 13 malignant lesions. In goitre nodules, concordant results of tetrofosmin and pertechnetate uptake (score 1 or 0) were observed in the majority of lesions (87%). In function adenomas both tetrofosmin uptake and pertechnetate uptake were score 3. In non-function adenomas tetrofosmin uptake was score 3, while pertechnetate uptake was score 0. In six malignant lesions, tetrofosmin uptake was score 3, while pertechnetate uptake was score 0; in the other seven lesions, where a prevalence of goitre abnormalities was observed, results of tetrofosmin and pertechnetate uptake were similar (score 0 or 1). In (70%) patients with malignant nodules, whole-body tetrofosmin images showed increased abnormal uptake in a total of 28 extra-thyroid tumour sites, as subsequently confirmed by other techniques. When tetrofosmin images were compared to 201 Tl and 99m Tc-MIBI scans, concordant results were observed in all cases. In conclusion, tetrofosmin imaging may be particularly useful to characterize and stage patients with malignant thyroid nodules; it shows similar results to thallium but provides better image quality. Comparable findings were observed between tetrofosmin and MIBI studies. Thus, tetrofosmin may be an alternative to thallium and MIBI in the aforementioned patients. (orig.). With 4 figs., 3 tabs

  2. Clinical comparison of technetium-99m-EC, technetium-99-m-MAG3 and Iodine-131-OIH in renal disorders

    International Nuclear Information System (INIS)

    Kabasakal, L.; Turoglu, T.; Oensel, C.

    1995-01-01

    Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of 99m Tc-EC were studied by constant infusion technique and compared with 99m Tc-MAG3 and 131 I-OIH in 11 patients with various renal disorders. After giving a 7.4 MBq 131 I-OIH and 90-110 MBq 99m Tc-EC or 99m Tc-MAG3 bolus, a constant infusion (MBq/ml) 99m Tc--agent and 0.07 MBq/m 131 I-OIH was started. Sixteen blood and five urine samples were obtained over three hr. The renal clearance of 99m Tc-EC was higher than than of 99m Tc-MAG3. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH ratios were 0.75 ± 0.05 and 0.55 ± 0.10 (p=0.00087), respectively. The distribution volume of 99m Tc-EC was also higher than that of 99m Tc-MAG3 (15722 ± 4644 and 9509 ± 2788 ml/1.73m 2 , respectively; p=0.072). The 99m Tc-EC/OIH and 99m Tc-MAG/OIH distribution volume ratios were 1.03 ± 0.14 and 0.55 ± 0.10, respectively (p = 0.0003). The 60-min excretion values of 99m Tc-EC and 99m Tc-MAG3 were compared to that of OIH. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH excretion ratios were 0.96 ± 0.06 and 1.07 ± 0.10, respectively (p=0.162). The protein binding of 99m -EC and OIH were found to be 34% ±4 and 66% ±5, respectively (p 99m Tc-EC was negligible (3% ±1.2) in comparison to OIH (27% ±3; p 99m Tc-EC. This agent has good potential for renal function evaluation. 32 refs., 5 tabs

  3. Treatment with radioisotopes (RI), (40). A discussion of a morphological diagnosis and a diagnosis of cell function in the liver with sup(99m)Tc-HIDA (sup(99m)Tc-PI) and sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Asahara, A [Central Hospital of JNR, Tokyo (Japan)

    1978-11-01

    sup(99m)Tc-N-N-(N'(2,6 dimethylphenyl) carbamoyl methyl) iminodiacetic acid (sup(99m)Tc-HIDA) or sup(99m)Tc-phytate was administered to the same case, and their uptake into the liver was discussed by hepatic scintigraphy and hepatogram. As a result, hepatic images of subjects with normal liver function and those with cholelithiasis whose biliary flow was normal were the same, and there was no difference in a morphological diagnosis between them. Sufficient images could not be obtained because sup(99m)Tc-HIDA uptake into the liver decreased in acute hepatitis and acute obstructive jaundice, but sufficient images could be obtained by using sup(99m)Tc-phytate and its uptake into the liver was normal. The uptake of both agents decreased in most of the subjects with liver cirrhosis. As a collective result of both agents, various specific patterns of their uptake were showed according to diseases. sup(99m)Tc-phytate is more useful when an examination is made only to take hepatic image, because this agent is less limit for hepatic imaging. Uptake of sup(99m)Tc-HIDA and sup(99m)Tc-phytate into the liver and their excretion were almost the same in most of diseases, and there was no difference in diagnostic application merits between them. Excretion rate of sup(99m)Tc-HIDA was very low in Dubin-Johnson syndrome, but that of sup(99m)Tc-pyridoxylidene isoleusin (PI) was almost normal. It was supposed that metabolism of sup(99m)Tc-HIDA in hepatic cells differs from that of sup(99m)Tc-PI. (Tsunoda, M.).

  4. Studies of techniques for the post-elution concentration of 99mTc obtained from gel type 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Suzuki, Katia Noriko

    2009-01-01

    On average 80% of the radiopharmaceuticals used in Nuclear Medicine are labeled with 99 mTc due to its physical properties and easy attainment through of 99 Mo/ 99 mTc generators. The Directory of Radiopharmacy (DIRF) of IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n,γ) 99 Mo reaction that occurs at the IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 mL with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (25 mCi)/mL. The fission generator gives a higher radioactive concentration around 1850 MBq (50 mCi)/mL. The aim of this work is to study a system of post-elution concentration of 99 mTc for the attainment of a high enough radioactive concentration to meet the demands of the market, with a proved quality. Two types of systems of post-elution concentration were developed: the single and the tandem. The most appropriate system for the gel generator of 99 Mo/ 99 mTc, being at the same time sterile and vacuum automated, was the tandem system using Dionex 2.5 cc/QMA cartridges. The gel generator is eluted with 10 mL of solution of 0.1% NaCl and the pertechnetate anion is retained in the QMA cartridge and further eluted with 4 mL of saline. The process takes no more than 30 minutes. The elution efficiency of the system of concentration was 90 %. At the beginning of 2009 a global crisis in the supply of 99 Mo took place making it necessary the development of alternative technologies for the production of 99 Mo/ 99 mTc generators using fission produced 99 Mo and the development of an appropriate method to extend the useful life of this generator. The results of this study showed that the same system developed for the post- concentration of the gel generator can be employed for the fission generator, using the tandem system, giving a concentration factor of 3 for the elution of 99 mTc. (author)

  5. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  6. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  7. Chemical form of tumor-tropic 99mTc-DL-homocysteine

    International Nuclear Information System (INIS)

    Takeda, A.; Okada, S.

    1989-01-01

    Analyses of the chemical forms of 99m Tc-complexes provide important information for the development of a new tumor-tropic 99m Tc-labeled radiopharmaceutical. We attempted to determine the chemical form of 99m Tc-DL-homocysteine ( 99m Tc-Hcy) which was previously reported to be tumor-tropic. By analyzing the functional residues of Hcy in the 99m Tc-Hcy molecule, it was estimated that the sulfhydryl and amino residues participated in the chelate formation. Gel filtration analysis of 99m Tc-Hcy indicated that its molecular size was bigger than that of 99m Tc-penicillamine monomer. The analysis also indicated that 99m Tc-Hcy complex seemed to be a relatively small oligomer. Although an uncertainty remains on the valency of Tc in 99m Tc-Hcy molecule and the accurate molecular size of this complex, its putative chemical form is described. (author)

  8. A review of sup(99m)Tc generator technology

    International Nuclear Information System (INIS)

    Molinski, V.J.

    1982-01-01

    The sup(99m)Tc generator has found widespread use because it is ideally suited for scintigraphy. The preparation of sup(99m)Tc generators using alumina and other ion exchange systems is described. Other methods of separating 99 Mo and sup(99m)Tc, such as solvent extraction and sublimation, are also discussed. Some of the problems associated with the alumina column type sup(99m)Tc generator are listed with possible causes and solutions to their problems. The current biomedical applications of the sup(99m)Tc radioisotope are the basis of a $100 million nuclear medicine business. The importance of the sup(99m)Tc generator makes it imperative that we understand and solve the problems associated with its manufacture. (author)

  9. Clinical comparison of I-131 orthoiodohippurate and the kit formulation of Tc-99m mercaptoacetyltriglycine

    International Nuclear Information System (INIS)

    Taylor, A. Jr.; Ziffer, J.A.; Steves, A.; Eshima, D.; Delaney, V.B.; Welchel, J.D.

    1989-01-01

    Previous studies in animals and humans have shown that technetium-99m mercaptoacetyltriglycine (MAG3) purified by high-performance liquid chromatography is a renal tubular agent with characteristics similar to those of iodine-131 orthoiodohippurate (OIH). A kit formulation for Tc-99m MAG3 has been developed and compared with I-131 OIH in 17 patients with suspected renal dysfunction and three potential kidney donors. There were no adverse reactions. Tc-99m MAG3 images were of good quality and consistently better than I-131 OIH images. There was no significant difference in the relative renal uptake of Tc-99m MAG3 and I-131 OIH. The 30-minute urinary excretion of Tc-99m MAG3 was 36.4%, versus 40.4% for I-131 OIH. The average plasma clearance of Tc-99m MAG3 (138 mL/min +/- 117) was less than that of I-131 OIH (272 mL/min +/- 205) (P less than .001); however, there was good correlation between the Tc-99m MAG3 and I-131 OIH clearances (r = .87). The volume of distribution of Tc-99m MAG3 (5.96 L +/- 1.94) was less than that of I-131 OIH (9.41 L +/- 3.73) (P less than .001). These characteristics and the advantages of a simple kit formulation should lead to widespread clinical use

  10. Technetium-99 in ''instant'' sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Mattsson, S.

    1978-01-01

    The 99 Tc-content in sup(99m)Tc-pertechnetate separated from 99 Mo by distillation or extraction has been studied with a plastic scintillation detector. The identification of the measured activity was achieved by beta-spectrometry, chemical separation and half-life studies. The frequency distribution of the sup(99)Tc/sup(99m)Tc-ratios in the different samples was observed to be log-normal. The most likely activity ratio was 0.4x10 -6 , the maximum value being 5x10 -6 . The specific activity of ''instant'' pertechnetate is approximately a factor of 60 lower than that normally recorded in pertechnetate derived from daily eluted column generators. The low specific activity of ''instant'' pertechnetate is primarily explained by the long time between separation and usage and secondly by the low yield of Tc in the distillation and extraction processes. In several of the ''instant'' pertechnetate solutions the carrier concentration exceeded the reductive capacity of the stannous ions in ''kits'' with small amounts of Sn(II) in usable form. (T.G.)

  11. Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2 = cyclohexanedione dioxime) as potential radiotracers for heart imaging

    International Nuclear Information System (INIS)

    Liu, Min; Zheng, Yumin; Avcibasi, Ugur; Liu, Shuang

    2016-01-01

    Introduction: In this study, novel 99m Tc(III)-azide complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] ( 99m Tc-ISboroxime-N 3 : R = IS; 99m Tc-MPboroxime-N 3 : R = MP; 99m Tc-PAboroxime-N 3 : R = PA; 99m Tc-PYboroxime-N 3 : R = PY; and 99m Tc-Uboroxime-N 3 : R = 5U) were evaluated as heart imaging agents. Methods: Complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] (R = IS, MP, PA, PY and 5U) were prepared by ligand exchange between NaN 3 and [ 99m TcCl(CDO)(CDOH) 2 B-R]. Biodistribution and imaging studies were carried out in Sprague–Dawley rats. Image quantification was performed to compare their initial heart uptake and myocardial retention. Results: 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were prepared with high RCP (93–98%) while the RCP of 99m Tc-MPboroxime-N 3 and 99m Tc-PAboroxime-N 3 was 80–85%. The myocardial retention curves of 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were best fitted to the bi-exponential decay function. The half-time of the fast component was 1.6 ± 0.4 min for 99m Tc-ISboroxime-N 3 , 0.7 ± 0.1 min for 99m Tc-PYboroxime-N 3 and 0.9 ± 0.4 min for 99m Tc-Uboroxime-N 3 . The 2-min heart uptake from biodistribution studies followed the ranking order of 99m Tc-ISboroxime-N 3 (3.60 ± 0.68%ID/g) > 99m Tc-PYboroxime-N 3 (2.35 ± 0.37%ID/g) ≫ 99m Tc-Uboroxime-N 3 (1.29 ± 0.06%ID/g). 99m Tc-ISboroxime-N 3 had the highest 2-min heart uptake among 99m Tc radiotracers revaluated in SD rats. High quality SPECT images were obtained with the right and left ventricular walls being clearly delineated. The best image acquisition window was 0–5 min for 99m Tc-ISboroxime-N 3 . Conclusion: Both azide coligand and boronate caps had significant impact on the heart uptake and myocardial retention of complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R]. Among the radiotracers evaluated in SD rats, 99m Tc-ISboroxime-N 3 has the highest initial heart uptake with the heart retention comparable to that of 99m Tc

  12. Comparison of Tc-99m Ciprofloxacin (Infecton) and Tc-99m Methylene diphosphonate (MDP) three-phase bone scintigraphy in the diagnosis of osteomyelitis in patients with Sickle Cell Disease

    International Nuclear Information System (INIS)

    Bererhi, H.; Hussein, S.; Wali, Y.

    2003-01-01

    The high incidence of Sickle Cell Disease (SCD) is a major health problem in Oman. These patients are more prone to infections than the general population, and in particular, they are highly susceptible to osteomyelitis. Because bone infarction is more common than osteomyelitis in SCD, an accurate and rapid differential diagnosis is essential before initiating appropriate treatment. The present prospective study evaluates the usefulness of the new radiopharmaceutical, Tc- 99m Ciprofloxacin (Infecton) for the differential diagnosis of infection and infarction in patients with SCD. Majority of subjects studied were children. The results of Tc-99m Infecton imaging were compared with those of the 3-phase bone scintigraphy using Tc- 99m Methylene diphosphonate (Tc-99m MDP). Twenty-five patients referred for ruling out infection were imaged after intravenous injection of 5.5 MBq/kg body weight of Tc-99m Infecton. First pass, blood pool and late images (at one, four and 24 hours post injection) were performed. Subsequently all patients were also studied by three-phase bone scintigraphy using Tc-99m MDP. No adverse effects were observed. The sensitivity, specificity, accuracy and positive likelihood ratio of Tc-99m Infecton imaging for osteomyelitis were 100%, 92%, 94% and 12.5 respectively. Although bone scintigraphy would rarely be used by itself as a stand-alone test in the diagnosis of osteomyelitis in patients with SCD, its corresponding values were: 88%, 64%, 71% and 2.4. The results of this study suggest that the use of Tc-99m Infecton imaging is extremely beneficial in the management of patients of Sickle Cell Disease with suspected osteomyelitis. (author)

  13. Comparison of Tc-99m-tetrofosmin and Tc-99m-MIBI scintimammography in differential diagnosis of breast mass

    International Nuclear Information System (INIS)

    Park, Jung Mi; Choi, Joon Young; Lee, Kyung Han; Choi, Yong; Choe, Yearn Seong; Kim, Sang Eun; Kim, Byung Tae; Nam, Seok Jin; Yang, Jeong Hyun

    2000-01-01

    Tc-99m-MIBI (MIBI) and Tc-99m-Tetrofosmin (TF) are commonly used for scintimammog (SMM). We compared the diagnostic ability of SMM using Tc-99m-MIBI and Tc-99m-TF for the differ diagnosis of breast mass. The study subjects were comprised of 123 breast lesior 86 normal breasts of 114 patients who underwent SMM. Bilateral prone images and anterior supine images obtained at 5 minutes and 1 or 3 hours after intravenous injection of 740 MBq of either MIBI or TF. of tumors were not significantly different between the MIBI and TF groups. First, two observers independ read the SMM without clinical information (1st interpretation), then read again with information about location (2nd interpretation). Sensitivity and specificity of each radiopharmaceutical for the diagnosis of cancer were evaluated in terms of image acquisition time, tumor size, and location. The SMM sb a good agreement between two observers for 1st and 2nd interpretation, except for TF SMM at hr. For first interpretation, the sensitivities at 5 min, 1 hr, and 3 hr were not significantly different between MIE TF SMM (81.6%, 80.0%, 60.9% in MIBI vs. 88.9%, 80.6%, 42.9% in TF), although the sensitivities of images were significantly lower than 5 min images in both MIBI and TF SMM. The specificity of TF at was superior to that of MIBI (81.5%, 90.0%, 82.9% in MIBI vs. 96.7%, 100%, 90.0% in TF, p<0.01 MB TF at 5 min). For the second interpretation with information of mass location, the sensitivities at 3 hr in were significantly lower than 5 min images (86.8%, 86.7%, 78.3% in MIBI vs. 88.9%, 93.5%, 57.1% in between MIBI and TF SMM. However, there was no significant difference in the specificity (60.0%, 5 75.0% for MIBI vs. 86.7%, 100%, 100% for TF). MIBI and TF SMM showed lower sensitivities for the t with less than 1 cm than tumors with more than 1 cm. However, the location of tumors did not influence sensitivity and specificity between MIBI and TF SMM. The ability for the differential diag of breast tumor is

  14. Biokinetics of osteotropic radiopharmaceuticals in metabolic osteopathies - comparison of /sup 47/Ca and sup(99m)Tc-MDP

    Energy Technology Data Exchange (ETDEWEB)

    Knop, J.; Montz, R.

    1983-10-01

    Plasma clearance and osseous accumulation rates of sup(99m)Tc methylene diphosphonate (MDP) in the lumbar spine were measured in 11 patients with osteoporosis (OP), 7 patients with hyperparathyroidism (HPT), 4 patients with osteomalacia (OM) and in 3 patients (N) who were studied to exclude metabolic bone disease. The findings in 19 patients were compared with the results of /sup 47/Ca kinetics. The plasma elimination of sup(99m)Tc-MDP during the first hour after application was normal in almost all the patients. The sup(99m)Tc-MDP accumulation rates in the lumbar spine were raised in patients with HPT and OM (p<=0,01) and normal in patients with OP and N (p>0,05). /sup 47/Ca kinetics were disturbed in most of the patients with metabolic bone disease, with minimal deviations in OP. The comparison of sup(99m)Tc-MDP accumulation rates with the results of /sup 47/Ca kinetics revealed significant correlations with exchangeable bone and soft tissue calcium. The correlations with total calcium turnover and calcium accretion were poor. Only half of the patients had equal results of sup(99m)Tc-MDP accumulation rates and bone calcium accretion rates. It is concluded that the sup(99m)Tc-MDP uptake by bone is an index of bone metabolism presumably of the organic matrix, whereas /sup 47/Ca kinetics represent the mineral metabolism of bone.

  15. A comparative study of 99mTc-HL91 and 99mTc-MIBI imaging in experimental tumor and inflammatory models

    International Nuclear Information System (INIS)

    Cao, W.; Zhang, X.Y.; An, R.

    2002-01-01

    Aim: 99m Tc-HL91 is a newly developed hypoxic imaging agent for ischemic myocardium and tumor imaging. 99m Tc-MIBI is one of imaging agent for mammary tumor imaging. The aim of this experiment is to evaluate the diagnostic value of 99m Tc-HL91 in detection of solid tumor in experimental tumor and inflammatory models, via comparative study with 99m Tc-MIBI. Material and Methods: HL91 kits was provided by China Nine Star Co. Three kinds of bearing solid neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice and bearing human ovarian COC 1 neoplasm nude mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static whole body planar images at 1 and 4 hours post injection of 99m Tc-HL91. Two kinds of bearing neoplasm mice groups (bearing Ehrlich carcinoma mice, bearing H 22 carcinoma mice) and two inflammatory model groups (chemical and bacterial inflammation) underwent static planar images post injection of 99m Tc-MIBI, at early phase (10∼20 minutes) and delayed phase (2 hrs). All of mice were sacrificed at 4 hrs. The tumors, or inflammatory lesions, blood and contralateral muscles were removed, weighed and the radioactivity was measured. Regions of interesting (ROIs) were drawn around tumor, inflammatory lesions and contralateral muscles in planar images, and the radioactivity ratios of target (tumor or inflammatory lesions)-to-blood (T/B), target-to-non target (contralateral muscles) i. e. T/NT was calculated. Results: Neoplasm can be clearly visible in planar images at 1hr and 4 hrs post injection of 99m Tc-HL91 in all tumor models. At same time inflammatory lesions cannot be seen clearly. Neoplasm can be seen in delayed phase in 99m Tc-MIBI groups, but not easy to distinguish them from inflammation. Conclusion: Compared with 99m Tc-MIBI imaging, 99m Tc-HL91 has much more diagnostic value in detection of solid neoplasm, and can distinguish neoplasm from inflammation

  16. Studies on quality control of technetium-99m labelling kits

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Park, Kyung Bae; Awh, Ok Doo

    1987-12-01

    Various experiments for the quality control of Tc-99m labelled radiopharmaceuticals such as Tc-99m-phytate, Tc-99m-MDP, Tc-99m-Tin Colloid, Tc-99m-DISIDA, Tc-99m-DTPA,Tc-99m-DMSA, Tc-99m-Gulcoheptonate, TC-99m-Pyrophosphate, Tc-99m-HSA, and Tc-99m-HAM were carried out. Labelling yield and radiochemical purity of each of the instant labelling kit of KAERI made were determined by means of radiochromatography. Biodistribution in mice and whole body or specific organ imagings of rabbits were also carried out and discussed the relationship between the data of biodistributions and radiochemical purities. Labelling yeilds were above 98% for almost all of the labelling kits. The radio-pharmaceuticals were accumulated at each target organ with moderate specifities. In case of radiochemical purity of above 98%, the biodistribution and gamma imagings were also better. The kits of MDP and DISIDA were stable at least for four moths while the other kits at least eight months. (Author)

  17. Standardization of Tc-99 by two methods and participation at the CCRI(II)-K2. Tc-99 comparison.

    Science.gov (United States)

    Sahagia, M; Antohe, A; Ioan, R; Luca, A; Ivan, C

    2014-05-01

    The work accomplished within the participation at the 2012 key comparison of Tc-99 is presented. The solution was standardized for the first time in IFIN-HH by two methods: LSC-TDCR and 4π(PC)β-γ efficiency tracer. The methods are described and the results are compared. For the LSC-TDCR method, the program TDCR07c, written and provided by P. Cassette, was used for processing the measurement data. The results are 2.1% higher than when applying the TDCR06b program; the higher value, calculated with the software TDCR07c, was used for reporting the final result in the comparison. The tracer used for the 4π(PC)β-γ efficiency tracer method was a standard (60)Co solution. The sources were prepared from the mixture (60)Co+(99)Tc solution and a general extrapolation curve, type: N(βTc-99)/(M)(Tc-99)=f [1-ε(Co-60)], was drawn. This value was not used for the final result of the comparison. The difference between the values of activity concentration obtained by the two methods was within the limit of the combined standard uncertainty of the difference of these two results. © 2013 Published by Elsevier Ltd.

  18. The evaluation of functioning thyroid nodules using sodium pertechnetate TC-99m scan in comparison with iodine-131

    Directory of Open Access Journals (Sweden)

    Saghari M

    1993-04-01

    Full Text Available Thyroid scintigraphy has been helpful in detecting and evaluation of thyroid nodules. Sodium pertechnetate Tc-99m is the most commonly used radionuclide for thyroid imaging because of its general availability, favorable dosimetric characteristics and low cost. But, there are reports of occasional disparity in isotope uptake in lesions compared with radioiodide. In order to determine percentage and clinical significance of this disparity, we screened 101 patients with solitary functioning nodules using sodium pertechnetate TC-99m in comparison with subsequent Iodine-131 scan in research institute for nuclear medicine. We conclude that sodium pertechnetate TC-99m is a reliable radiotracer for the detection and evaluation of thyroid nodules and there is no need for the subsequent Iodine-131 scan.

  19. Use of 99mTc-HMPAO-leucocyte scintigraphy coupled to 99mTc-colloid scintigraphy in diagnosing the osteo-articular sepsis

    International Nuclear Information System (INIS)

    Darlas, Y.; Pegoix, M.; Filmont, J.E.; Leclercq, S.; Rosas, M.H.; Agostini, D.; Aubriot, J.H.; Bouvard, G.

    1997-01-01

    The object of this study was the scintigraphic diagnosis of osseous sepsis based on the absence of congruence between leucocytic and colloidal fixations and the evaluation of the effect of coupling between the scintigraphies (sc) with leucocytes (A) and colloids (B) on the diagnosis feasibility index of this technique. Seventy four patients, 97 sc were divided into two groups according to the scintigraphic technique [(A) only]: 35 sc; [(A) and (B)]: 62 sc. [Prosthesis: 48 patients, 68 sc. Osteitis: 26 patients, 29 sc]. The scintigraphies were performed as follows: (A) autologous leucocytes labelled by 250 - 300 MBq of 99m Tc-HMPAO, with planar incidences (15 min), 3 - 4 hours after injection and (B) Labelled nano-colloids labelled by 180 - 200 MBq of 99m Tc, the same incidences, 30 min after injection. The delay between (A) and (B): 48 hours. The final diagnosis of sepsis: bacteriological and histologic criteria after biopsies and/or clinical, biological and radiological evolution. The comparison between the two groups is given in a table in terms of prevalence, sensitivity and specificity, using the χ2 and Fisher tests. In conclusion, the scintigraphy by 99m Tc-HMPAO-leucocyte is a sensitive method (Se ∼ 90%) for the diagnosis of osseous sepsis and coupled to the scintigraphy by 99m Tc-colloids allow obtaining a high specificity (Sp ≥ 90%) by reducing the number of falsely positive diagnoses

  20. Imaging-based evaluation of liver function: comparison of {sup 99m}Tc-mebrofenin hepatobiliary scintigraphy and Gd-EOB-DTPA-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Gebauer, Bernhard [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Luedemann, Lutz [Essen University Hospital, Department of Medical Physics, Essen (Germany); Froeling, Vera; Denecke, Timm [Charite Campus Virchow-Klinikum, Department of Diagnostic and Interventional Radiology, Berlin (Germany); Charite Campus Virchow-Klinikum, Department of Nuclear Medicine, Berlin (Germany); Malinowski, Maciej; Stockmann, Martin; Baron, Annekathrin; Seehofer, Daniel [Charite Campus Virchow-Klinikum, Department of General, Visceral and Thoracic Surgery, Berlin (Germany); Prasad, Vikas [Charite Campus Virchow-Klinikum, Department of Nuclear Medicine, Berlin (Germany)

    2015-05-01

    To compare Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests for separate evaluation of right (RLL) and left liver lobe (LLL) function. Fourteen patients underwent Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin HBS after portal vein embolization within 24 h. Relative enhancement (RE) and hepatic uptake index (HUI) were determined from MRI; and T{sub max}, T{sub 1/2} and mebrofenin uptake were determined from HBS, all values separately for RLL and LLL. Mebrofenin uptake correlated significantly with HUI and RE for both liver lobes. There was strong correlation of mebrofenin uptake with HUI for RLL (r{sup 2} = 0.802, p = 0.001) and RE for LLL (r{sup 2} = 0.704, p = 0.005) and moderate correlation with HUI for LLL (r{sup 2} = 0.560, p = 0.037) and RE for RLL (r{sup 2} = 0.620, p = 0.018). Correlating the percentage share of RLL function derived from MRI (with HUI) with the percentage of RLL function derived from mebrofenin uptake revealed a strong correlation (r{sup 2} = 0.775, p = 0.002). Both RE and HUI correlate with mebrofenin uptake in HBS. The results suggest that Gd-EOB-enhanced MRI and {sup 99m}Tc-mebrofenin HBS may equally be used to separately determine right and left liver lobe function. (orig.)

  1. Physicochemical and Biological Analysis of 99mTc-Glutathione Radiopharmaceuticals

    International Nuclear Information System (INIS)

    ME- Sriyani; N- Zainuddin

    2013-01-01

    99m Tc-glutathion ( 99m Tc-GSH) radiopharmaceutical is available in the GSH lyophilized-kit in which ready to use directly after adding 99m Tc radionuclide. In nuclear medicine, 99m Tc-GSH diagnostic kit is a radiopharmaceutical commonly utilized for cancer diagnoses using imaging method. This paper described the physicochemical and biological characteristics as well as the quality of 99m Tc-GSH diagnostic kit prepared from the GSH lyophilized-kit. The radiochemical purity was determined with thin layer chromatography (TLC) method, performed on a TLC-SG stationary phase with a mobile phase of a dried acetone and 0,9% of NaCl solution. Studies on the effect of volume and radioactivity of Na 99m TcO 4 solution to the radiochemical purity of 99m Tc-GSH were carried out. The sterility of GSH-lyophilized kit and toxicity of 99m Tc-GSH were also investigated. The stability test on GSH lyophilized kit and 99m Tc-GSH in several storage conditions, as well as the plasma stability of 99m Tc-GSH was performed. The analysis result showed that the GSH lyophilized-kit was sterile; the 99m Tc-GSH was non toxic with 99.54 ± 0.01% of radiochemical purity and remained stable 5 hours either at room temperature or 4℃. The volume more than 4 mL of Na 99m TcO 4 solution on the labeling of GSH could decreased the 99m Tc-GSH radiochemical purity, while the radioactivity more than 20 mCi in 7 mL of volume extended the incubation time. In-vitro stability test of 99m Tc-GSH in plasma showed that in the two hours of storage, the radiochemical purity decreased to 51.84 ± 2.52%, and until 5 hours of storage it did not change significantly. From the result, it can be concluded that the GSH lyophilized-kit was remained stable after 13 month of storage either at room temperature or 4℃ with 99% of 99m Tc-GSH radiochemical purity. (author)

  2. Investigation of renovascular hypertension with 99mTC-DTPA dynamic renal scanning and digital subtraction angiography

    International Nuclear Information System (INIS)

    Stavraka-Kakavakis, A.; Vlontjou, E.; Apostolopoulos, D.; Mourikis, D.; Venetsanakis, N.; Lazarou, S.; Vlahos, L.

    1989-01-01

    Sixty-four selected hypertensive patients, aged 17-45 years, were evaluated for renovascular hypertension. They were studied with 99m TC-DTPA dynamic renal scanning (DRS) and intravenous digital subtraction angiography (IV-DSA). Intra-arterial DSA was further performed to demonstrate renal vascular anatomy in all disputable cases. Agreement of diagnosis occurred in 58 patients (32 with renal artery stenosis). There was one false positive with DRS and one false positive with IV-DSA. In another four patients with proven renovascular disease, IV-DSA was positive while DRS negative, but in two of them the stenotic lesion was considered insignificant, as they failed to respond to percutaneous transluminal dilatation (PTA). In contrast, nearly all patients whose hypertension improved after PTA or surgery had positive DRS and greater than 40% reduction of relative function of the affected kidney. IV-DSA yielded better results than DRS in the detection of renal arterial stenosis (especially whenever bilateral stenosis or rich collateral circulation was present), but DRS showed better correlation with the functional significance of a certain vascular abnormality. Thus the combination of the two methods seems to be a reasonable diagnostic approach to hypertensive patients with the aim of selecting those with curable hypertension due to renal vascular disease. (orig.)

  3. 99Mo-99mTc generator - study of their performance and quality

    International Nuclear Information System (INIS)

    Acar, M.E.D.

    1987-01-01

    In this work the performance of the 99 Mo - 99m Tc generators produced at IPEN-CNEN/SP as well as the quality of the eluted solutions were analysed. The following parameters were studied: elution efficiency, chemical radiochemical, radionuclidic and microbiological purities and pH of the eluates. The 99m Tc yield ranged from 84,7 to 98,5%. The radioactivity due to the pertechnetate ion in the studied solutions was higher than 97,5%. The aluminium content in eluates, determined by spectrophotometry, was lower than 2,5 μg/ml and the pH of the solutions between 4,5 and 5,1. Radioactive impurities of the order of 10 -3 KBq 99 Mc/MBq 99m Tc and 10 -5 KBq 131 I/MBq 99m Tc were found in the eluates at the time of elution. Other γ emitting radioactive impurities were order of 10 -3 KBq/MBq 99m Tc. The eluates were sterile and pyrogen-free. From the results obtained in this work one can state that the IPEN-TEC generator is a reliable source of good quality 99m Tc-pertechnetate. (author) [pt

  4. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon 'bomb'

    International Nuclear Information System (INIS)

    Varelis, P.; Poot, M.T.

    1998-01-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a 'bomb'. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  5. An expedient method for the preparation of 99mTc-MIBI and 99mTc-MAG3 using microwave and teflon `bomb`

    Energy Technology Data Exchange (ETDEWEB)

    Varelis, P.; Poot, M.T. [St George Hospital, Sydney, NSW (Australia). Department of Nuclear Medicine

    1998-06-01

    Full text: The recommended method for the preparation of 99mTc-MIBI and 99mTc-MAG3 requires that they be heated in a boiling water bath for 10 minutes, after reconstitution with sodium pertechnetate. This method is both inconvenient and time consuming. A more rapid and convenient method for the preparation of these radiopharmaceuticals employs a conventional microwave oven. However, a serious limitation of this method is the hazard associated with an explosion of a vessel containing a radioactive substance. Traditionally, mixtures that can potentially explode are contained in a device called a `bomb`. We have developed a method, utilising such a device, that allows us to rapidly and safely prepare 99mTc-MIBI and 99mTc-MAG3 using a microwave oven. This device is used in our department on a daily basis. Since using the teflon bomb, there has been one incidence of an explosion, which was successfully contained within the bomb. There was no statistically significant difference between the radiochemical purity (RCP) of the microwave prepared samples and those obtained using the recommended method. In conclusion, 99mTc-MIBI and 99mTc-MAG3 can be safely prepared and quality controlled in under ten minutes using a microwave oven and our teflon bomb. The average RCP for 99mTc-MIBI and 99mTc-MAG3 prepared using a microwave oven were 97.0+2.0% (n=19) and 99.8+0.2 (n=7) respectively

  6. Study and preparation of 99Tcm-GP kit for lung ventilation imaging

    International Nuclear Information System (INIS)

    Zhu Lin; Meng Fanmin; Zhang Jihong; Hong Tao; Liu Yunzhong; Liu Xiujie

    1997-01-01

    The preparation of the lyophilizing reagent, D-glucose-l-phosphate (GP) kit and the method of using this kit to label 99 Tc m to form 99 Tc m -GP for lung ventilation imaging at room temperature in a simple, rapid procedure are described. The stability of the lyophilizing reagent kit under various stock conditions is examined. The results show that all of the 99 Tc m -GP yields by the lyophilizing reagent kit are above 95% at 4 degree C (cold), 20-25 degree C (room temperature) and 40 degree C (oven) for 180, 90 and 3 days, respectively. The clinical practice indicates that in comparison with 99 Tc m -DTPA, 99 Tc m -GP has remarkable difference (P 99 Tc m -GP is an ideal radioaerosol for SPECT studies of lung ventilation. It has high alveolar deposition rate but low adhesion in the major airways compared to those of 99 Tc m -DTPA. 99 Tc m -GP also features prolonged pulmonary clearance time

  7. Minimizing Molybdenum 99 contamination in Technetium 99m Pertechnetate from the elution of 99Mo/ 99m Tc Generator

    International Nuclear Information System (INIS)

    Zakaria Ibrahim; Zulkifli Hashim; Bohari Yaacob

    2011-01-01

    Radioisotope Tc-99m is widely used for variety of nuclear medicine diagnostic procedures. For many commercial applications, it is prepared in a portable type generator. Nuclear Malaysia has been producing a dry type alumina chromatographic column generator utilizing fission Mo-99. This injectable Tc-99m must meet the British Pharmacopeia [1] product specification prior to be apply on patient. This paper provides a method to minimize the up to acceptable level Mo-99 in the final product. Purposely made pertechnetate contaminated with Mo-99 and re-eluate by using old generator. Excellent removal of Mo-99 impurity was achieved and more than 80 % of Tc-99m total activity was recovered. (author)

  8. Hepatobiliary scintigraphy and function test with sup(99m)Tc-N-pyridoxyl-5-methyltryptophan (sup(99m)Tc-PMT)

    International Nuclear Information System (INIS)

    Sugimura, Kazuro; Nishiyama, Shoji; Narabayashi, Isamu

    1985-01-01

    The authors studied the effectiveness of sup(99m)Tc-N-pyridoxyl-5-methyltryptophan (sup(99m)Tc-PMT) for dynamic imaging and function on 40 patients with various hepatobiliary diseases and on healthy individuals. In healthy subjects, sup(99m)Tc-PMT is rapidly removed from the blood by the parenchymal cells of the liver and is excreted through the biliary system. The imaging of the liver, bile ducts, gallbladder and intestines with sup(99m)Tc-PMT was satisfactory. There was no renal visualization. In the case of serial images of healthy individuals, the gallbladder, intrahepatic bile duct and small intestine were visualized after 18.8 +- 7.2, 8.8 +- 1.4, and 16.7 +- 6.3 min, respectively; the mean peak time on the hepatogram was 8.0 +- 5.3 min. The bile ducts of patients with liver disorders were visualized later than those of healthy individuals. Particularly in the case of severe liver parenchymal diseases, the appearance time for the bile duct was significantly delayed. However, the delays in appearance time did not correlate well with low scores on the liver function test. At 70 min after the intravenous administration of sup(99m)Tc-PMT, 2.5 +- 1.5 % of the injected dose was excreted into the urine of the healthy individuals. The urinary excretion of sup(99m)Tc-PMT by the patients with hepatobiliary diseases showed no increase, and it was not entirely related to the results of the serum function tests. However, a larger amount of sup(99m)Tc-PMT was retained in the blood of the patients with hepatobiliary diseases. The blood retention values at 20 min after injection into those with liver cirrhosis and hepatoma were significantly delayed. (author)

  9. Tc-99m Ciprofloxacin SPECT of Pulmonary Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of); Choe, Won Sick [Kangbuk Samsung Hospital, Seoul (Korea, Republic of)

    2010-06-15

    Tc-99m ciprofloxacin is available for imaging infection. However, there has been no study on employing single photon emission computed tomography (SPECT) with using Tc-99m ciprofloxacin to image active pulmonary tuberculosis. Therefore, we conducted this study to assess the efficacy of Tc-99m ciprofloxacin SPECT for imaging active pulmonary tuberculosis. Twenty-one participants were enrolled in this prospective study. They were divided into two groups according to the clinical and radiological assessment. Group one (Gr. 1) consisted of five normal volunteers and six patients with inactive pulmonary tuberculosis. Group two (Gr. 2) consisted of ten patients with active pulmonary tuberculosis. SPECT was performed 3 h after injecting 555 MBq (15 mCi) of Tc-99m ciprofloxacin. The findings of Tc-99m ciprofloxacin SPECT were interpreted by a nuclear medicine specialist and then the results were analyzed according to the patients' clinical and radiological classifications. The results of Tc-99m ciprofloxacin SPECT were as follows: eight true-positive cases, ten true-negative cases, one false-positive case and two false-negative cases. The sensitivity and specificity was 80.0% and 90.0%, respectively. The positive predictive value was 88.9% and the negative predictive value was 83.3%. Conclusions Tc-99m ciprofloxacin SPECT is feasible for imaging active pulmonary tuberculosis. It is a useful nuclear-imaging method for discriminating between the active and inactive tuberculosis states in patients with a past medical history of pulmonary tuberculosis.

  10. Evaluation of six new /sup 99m/Tc-IDA agents for hepatobiliary imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chervu, L.R.; Joseph, J.A.; Chun, S.B.; Rolleston, R.E.; Synnes, E.I.; Thompson, L.M.; Aldis, A.E.; Rosenthall, L.

    1988-10-01

    IDA derivatives of three substituted benzothiazol, and two substituted chlorophenyl and one substituted pyrazoline compounds have been labeled with /sup 99m/Tc and screened with four rat models with hepatocellular dysfunction manifesting varying degrees of change of liver architecture and hepatocellular damage associated with an active parenchymal destruction, fatty metamorphosis and cirrhosis. Organ distribution studies at 1 h postinjection have been compared in normal and diseased animal models for each agent labeled with /sup 99m/Tc and with /sup 99m/Tc-Disofenin (Disida) and Lidofenin (Hida) and /sup 131/I-Rose Bengal. From the data obtained with the six new IDA derivatives, the distribution kinetics of /sup 99m/Tc-Arclophenin, (N-N'-2-benzoyl-4-chlorophenyl)carbamoylmethyl) imino diacetic acid (Phenida), are closely comparable to /sup 99m/Tc-Disofenin in all animal models. Crossover patient studies (n = 14) for clinical evaluation of /sup 99m/Tc-Arclophenin vs /sup 99m/Tc-Disofenin indicate the close similarity of the 2 agents with regard to blood pool retention, gross liver/heart ratios and liver washout, suggesting Arclophenin as a suitable agent for hepatobiliary function studies. The impaired hepatocellular animal models presented should serve for fast screening of hepatobiliary agents and enable comparison of a series of closely related compounds.

  11. /sup 99m/Tc-aprotinin: A new tracer for kidney morphology and function

    International Nuclear Information System (INIS)

    Bianchi, C.; Donadio, C.; Tramonti, G.; Lorusso, P.; Bellitto, L.; Lunghi, F.

    1984-01-01

    Aprotinin (Ap), a low molecular weight polyeptide (6500 dalton), is a protease inhibitor which is electively and stably accumulated in the kidney. In 112 adult patients, with either uni- or bilateral renal disease with different degrees of renal impairment (from normal GFR to advanced renal failure), renal scans were performed by means of Ap labelled with /sup 99m/Tc. Highly satisfactory renal scans were obtained in all patients. In 20 patients with renal failure (serum creatinine 1.8 - 8.5 mg/dl, mean 4.7) a comparison was made of the renal scans obtained with /sup 99m/Tc-Ap and with /sup 99m/Tc-DMSA. /sup 99m/Tc-Ap was slightly better than /sup 99m/Tc-DMSA, especially in patients with far advanced renal failure. Some aspects of the pharmacokinetics of /sup 99m/Tc-Ap were studied in 72 cases. In 22 of these patients plasma clearance of /sup 99m/Tc-Ap was determined by the single injection method using a two-compartment model. In patients with GFR>90 ml/min plasma cl of /sup 99m/Tc-Ap was 67.6 +- 8.4 SD ml/min. A good correlation was observed between plasma clearance of /sup 99m/Tc-Ap and GFR (r = 0.74). After i.v. injection /sup 99m/Tc-Ap was stably fixed by the kidney. Renal radioactivity remained stable between the 2nd and the 8th hour after the injection. Urinary excretion of radioactivity measured in 35 patients in the first and in the second 2-hour interval after i.v. injection of /sup 99m/Tc-Ap was negligible in all patients (2.7 +- 1.5 SD percent of the dose in the fist 2 hours; 2.8 +- 1.4 SD between the 2nd and the 4th hour). Conclusions. /sup 99m/Tc-Ap is an excellent agent for renal imaging. It also seems promising for renal function studies

  12. sup(99m)Tc-aprotinin: A new tracer for kidney morphology and function

    International Nuclear Information System (INIS)

    Bianchi, C.; Donadio, C.; Tramonti, G.; Lorusso, P.; Bellitto, L.; Consiglio Nazionale delle Ricerche, Pisa

    1984-01-01

    Aprotinin (Ap), a low-molecular-weight polypeptide (6500 dalton), is a protease inhibitor which is electively and stably accumulated in the kidney. In 112 adult patients, with either uni- or bilateral renal disease with different degrees of renal impairment (from normal GFR to advanced renal failure), renal scans were performed by means of Ap labelled with sup(99m)Tc. Highly satisfactory renal scans were obtained in all patients. In 20 patients with renal failure (serum creatinine 1.8-8.5 mg/dl, mean 4.7) a comparison was made of the renal scans obtained with sup(99m)Tc-Ap and with sup(99m)Tc-DMSA. sup(99m)Tc-Ap was slightly better than sup(99m)Tc-DMSA, especially in patients with far advanced renal failure. Some aspects of the pharmacokinetics of sup(99m)Tc-Ap were studied in 72 cases. In 22 of these patients plasma clearance of sup(99m)Tc-Ap was determined by the single injection method using a two-compartment model. In patients with GFR>90 ml/min plasma clearance of sup(99m)Tc-Ap was 67.6+-8.4 SD ml/min. A good correlation was observed between plasma clearance of sup(99m)Tc-Ap and GFR (r=0.74). After IV injection sup(99m)Tc-Ap was stably fixed by the kidney. Renal radioactivity remained stable between the second and eighth hours after the injection. Urinary excretion of radioactivity measured in 35 patients in the first and in the second 2-h interval after IV injection of sup(99m)Tc-Ap was negligible in all patients (2.7+-1.5 SD percent of the dose in the first 2 h; 2.8+-1.4 SD between the second and fourth hour). sup(99m)Tc-Ap is an excellent agent for renal imaging. It also seems promising for renal function studies. (orig.)

  13. Plasma clearance and biodistribution of oxidatively modified 99mTc-ß-VLDL in rabbits

    Directory of Open Access Journals (Sweden)

    Silva E.L.

    1997-01-01

    Full Text Available The biodistribution and removal from plasma (measured as fractional clearance rate, FCR, per hour of native and oxidatively modified 99mtechnetium-labeled ß-very low density lipoprotein (99mTc-ß-VLDL were investigated in hypercholesterolemic (HC and control (C three-month old New Zealand rabbits. The intracellular accumulation of ß-VLDL labeled with 99mTc was studied in vitro in THP-1 cells and monocyte-derived macrophages isolated from rabbits. After intravenous injection into C rabbits, copper-oxidized ß-VLDL (99mTc-ox-ß-VLDL was cleared from the circulation faster (0.362 ± 0.070/h than native ß-VLDL (99mTc-nat-ß-VLDL, 0.241 ± 0.070/h. In contrast, the FCR of 99mTc-ox-ß-VLDL in HC rabbits was lower (0.100 ± 0.048/h than that of 99mTc-nat-ß-VLDL (0.163 ± 0.043/h. The hepatic uptake of radiolabeled lipoproteins was lower in HC rabbits (0.114 ± 0.071% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.116 ± 0.057% injected dose/g tissue for 99mTc-ox-ß-VLDL than in C rabbits (0.301 ± 0.113% injected dose/g tissue for 99mTc-nat-ß-VLDL and 0.305 ± 0.149% injected dose/g tissue for 99mTc-ox-ß-VLDL. The uptake of 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL by atherosclerotic aorta lesions isolated from HC rabbits (99mTc-nat-ß-VLDL: 0.033 ± 0.012% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.039 ± 0.017% injected dose/g tissue was higher in comparison to that of non-atherosclerotic aortas from C rabbits (99mTc-nat-ß-VLDL: 0.023 ± 0.010% injected dose/g tissue and 99mTc-ox-ß-VLDL: 0.019 ± 0.010% injected dose/g tissue. However, 99mTc-nat-ß-VLDL and 99mTc-ox-ß-VLDL were taken up by atherosclerotic lesions at similar rates. In vitro studies showed that both monocyte-derived macrophages isolated from rabbits and THP-1 macrophages significantly internalized more 99mTc-ox-ß-VLDL than 99mTc-nat-ß-VLDL. These results indicate that in cholesterol-fed rabbits 99mTc-ox-ß-VLDL is slowly cleared from plasma and accumulates in

  14. Achalasia diagnosed by 99mTc pertechnetate scintigraphy

    International Nuclear Information System (INIS)

    Mikosch, P.; Gallowitsch, H.J.; Kresnik, E.; Lind, P.

    1997-01-01

    A 73-year-old patient presented a 99m Tc scintiscan with a focal tracer accumulation left and caudal of the thyroid gland. Further investigations with sonography, CT, esophagoscopy and barium swallow provided the diagnosis of achalasia as the reason for focal 99m Tc retention caudal of the thyroid gland. Explanation for 99m Tc accumulation within the esophagus may be the nonspecific accumulation of 99m Tc not only in the thyroid gland but also in the salivary glands. Excretion of the tracer follows with the saliva. Structural and motor disorders of the esophagus can thus lead to focal tracer retention within the esophagus simulating thyroid tissue. (orig.) [de

  15. Problems in clinical practice of domestic supply of 99Mo/99mTc. Considerations on the domestic production of 99Mo/99mTc

    International Nuclear Information System (INIS)

    Yamabayashi, Hisamichi

    2012-01-01

    At present, a bulky import product, 99 Mo supplied in Japan is produced by a nuclear fission method which enables to produce a generator system with no need of commercially preparing 99m Tc-labeled radiopharmaceuticals due to its high specific activity. However its usage of enriched uranium target leads to avoiding the fission method from the option of domestic production. In order to secure the domestic supply of 99 Mo/ 99m Tc, the neutron activation method, aiming to meet about 20% of domestic demand, is under development along with the re-start program of JMTR. Development of various production methods using accelerators are also in progress. In those non-fission methods with reactors or accelerators, rapid and effective procedures for concentration and refinement of 99m Tc solution eluted from 99 Mo of low specific activity are the subjects to be considered for attaining the stable labeling performances. (author)

  16. Basic and clinical studies on hepatobiliary function test with sup(99m)Tc-PI

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Shigemoto, Hirosada; Ito, Yasuhiko; Muranaka, Akira; Ohtsuka, Nobuaki

    1979-01-01

    In these basic and clinical studies, the usefulness of sup(99m)Tc-pyridoxilideneisoleucine, a new hepatobiliary agent, was evaluated for a hepatobiliary function test in comparison with sup(99m)Tc-N-[N-(2,6 dimethylphenyl)carbamoylmethyl] iminodiacetic acid (HIDA) and 131 I-rose bengal (RB). The experiments were performed with 2.5 - 5 kg rabbits. Hepatic uptake and the excretion of sup(99m)Tc-pyridoxylidene isoleucine (PI) were earlier than those of 131 I-RB. However, biliary excretions of sup(99m)Tc-PI and sup(99m)Tc-HIDA were less than that of 131 I-RB, because urinary excretions of sup(99m)Tc-labeled compounds were greater. During the first 2.5 - 5 min, sup(99m)Tc-labeled agents had lower blood levels than 131 I-RB. At 6 days after the choledochal ligation, no hepatic uptake of sup(99m)Tc-PI was noted, although 131 I-RB concentrated to the liver. Blood retention of sup(99m)Tc-PI might not always reflect hepatobiliary function, especially in the hyperbilirubinemia. On the other hand, hepatograms from a region of interest corresponding to the liver varied with changes in the serum bilirubin level, although no hepatic uptake was detected in the complete obstructive jaundice and severe parenchymal liver disease being over 7 mg/dl in the serum bilirubin level. (author)

  17. Comparison of biological properties of 99mTc-labeled cyclic RGD Peptide trimer and dimer useful as SPECT radiotracers for tumor imaging

    International Nuclear Information System (INIS)

    Zhao, Zuo-Quan; Yang, Yong; Fang, Wei; Liu, Shuang

    2016-01-01

    Introduction: This study sought to evaluate a 99m Tc-labeled trimeric cyclic RGD peptide ( 99m Tc-4P-RGD 3 ) as the new radiotracer for tumor imaging. The objective was to compare its biological properties with those of 99m Tc-3P-RGD 2 in the same animal model. Methods: HYNIC-4P-RGD 3 was prepared by reacting 4P-RGD 3 with excess HYNIC-OSu in the presence of diisopropylethylamine. 99m Tc-4P-RGD 3 was prepared using a kit formulation, and evaluated for its tumor-targeting capability and biodistribution properties in the BALB/c nude mice with U87MG human glioma xenografts. Planar and SPECT imaging studies were performed in athymic nude mice with U87MG glioma xenografts. For comparison purpose, 99m Tc-3P-RGD 2 (a α v β 3 -targeted radiotracer currently under clinical evaluation for tumor imaging in cancer patients) was also evaluated in the same animal models. Blocking experiments were used to demonstrate the α v β 3 specificity of 99m Tc-4P-RGD 3 . Results: 99m Tc-4P-RGD 3 was prepared with > 95% RCP and high specific activity (~ 200 GBq/μmol). 99m Tc-4P-RGD 3 and 99m Tc-3P-RGD 2 shared almost identical tumor uptake and similar biodistribution properties. 99m Tc-4P-RGD 3 had higher uptake than 99m Tc-3P-RGD 2 in the intestines and kidneys; but it showed better metabolic stability. The U87MG tumors were clearly visualized by SPECT with excellent contrast with 99m Tc-4P-RGD 3 and 99m Tc-3P-RGD 2 . Conclusion: Increasing peptide multiplicity from 3P-RGD 2 to 4P-RGD 3 offers no advantages with respect to the tumor-targeting capability. 99m Tc-4P-RGD 3 is as good a SPECT radiotracer as 99m Tc-3P-RGD 2 for imaging α v β 3 -positive tumors. -- Graphical abstract: This report presents evaluations of a 99m Tc-labeled cyclic RGD peptide trimer ( 99m Tc-4P-RGD 3 ) as the new SPECT radiotracer for tumor imaging. It was found that 99m Tc-4P-RGD 3 was able to accumulate in the xenografted U87MG tumors with high specificity. Display Omitted

  18. Balloon-based adjuvant radiotherapy in breast cancer: comparison between 99mTc and HDR 192Ir

    Directory of Open Access Journals (Sweden)

    Tarcísio Passos Ribeiro de Campos

    2016-04-01

    Full Text Available Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.

  19. Labelling of red blood cells with 99m pertechnetate

    International Nuclear Information System (INIS)

    Vyth, A.; Raam, C.F.

    1979-07-01

    This paper describes a method for labelling red blood cells with 99mTc in vitro, using electrolytically generated stannous ions as the reducing agent for 99mTc-pertechnetate. A labelling of 95% was found. A method for the in vivo labelling of red blood cells is also reported. This involves an injection of a stanno-DTPA-complex followed 20 minutes later by a 99mTc-pertechnetate solution scintillation camera images show more background activity when the in vivo method of labelling is used

  20. Assessment of hepatocyte and kupffer cell function using Tc-99m DISIDA/Tc-99m tin colloid in thioacetamide-induced liver injury

    International Nuclear Information System (INIS)

    Ahn, B. C.; Chun, K. A.; Lee, J.; Lee, K. B.

    1997-01-01

    Toxic liver injury is not unusual in clinical field and liver biopsy is one of the most accurate method to define the severity of liver injury. But occasionally, it is impossible to obtain liver tissue in patients with acute toxic liver injury. The aim of this study is to evaluate the possibility of liver scintigraphy with Tc-99m DISIDA or Tc-99m tin colloid as a non-invasive tool in predicting functional status of hepatocyte and Kupffer cell and severity of liver injury. Intraperitoneal injection of thioacetamide was performed to make acute liver injury in mice and rats, and liver status was assessed by pathologic specimen and scintigraphic methods. Scintigraphic evaluation were performed by biodistribution of Tc-99m DISIDA or Tc-99m tin colloid in thioacetamide-treated mice. Liver time-activity curves were generated. Comparison between histologic data and scintigraphic data was done with SAS program. Thioacetamide-treated mice demonstrated hepatocyte necrosis in histologic examination and low liver/blood uptake ratios in biodistribution studies using both radiotracers. Biodistribution study using Tc-99m tin colloid revealed increased lung radioactivity in thioacetamide-treated mice. Twenty-four hours after thioacetamide administration, thioacetamide-treated rats demonstrated maximal hepatocyte necrosis and inflammation in histologic finding and delayed maximal uptake time (Tmax) and prolonged half time (T 1/2 ) of liver time-activity curve in liver scintigraphy. Histologic results and scintigraphic data were well correlated, and these two scintigraphic parameters (Tmax T 1/2 ) seemed to be good predictors of histologic change of liver. These data showed that liver injury could be assessed by non-invasive scintigraphic study in rat and mouse. This experimental study might be used as a animal model to evaluate the liver protecting drugs, and this scintigraphic study could be applied to acute toxic hepatitis for assessment of liver status in men

  1. Lymphoscintigraphy in melanoma patients using Tc-99m dextran

    International Nuclear Information System (INIS)

    Marciano, D.; Padgett, H.; Henze, E.; Carlson, C.; Bennett, L.R.

    1984-01-01

    Surgical removal of regional lymph nodes draining the site of a melanoma is a generally practiced procedure. It is often difficult in many cases of truncal melanomas near the midline or near the waistline to determine which group or groups of nodes to remove. Colloidal Au-198, Tc-99m sulfur colloid, and Tc-99m antimony sulfur colloid have all been used and have given useful clinical information. Objections, however, have been raised to the local radiation dose with these compounds. To reduce this problem while obtaining greater information on lymph flow, the authors have studied dextran, a macromolecule commonly used as plasma substitute. Dextran (average mol. wt. 72,000) labeled with Tc-99m has been used to study lymph drainage from the site of truncal melanoma in 29 patients. Serial images in the first hour following intradermal injection clearly demonstrate tracer in efferent lymphatics within 5 to 10 minutes, and brief pooling in the regional lymph nodes between 20 and 60 minutes. When compared with particulate tracers such as micro Tc-99m sulfur colloid, the Tc-99m dextran appears to move much faster through the lymphatics. Overall distribution of the Tc-99m dextran to lymph nodes is very similar to previous findings with micro Tc-99m sulfur colloid. Dextran drainage to more than one group of regional nodes was seen in 12/29 patients as compared with 17/50 patients using micro Tc-99m sulfur colloid. The superior images with Tc-99m dextran appear to make it the agent of choice

  2. Role of scintigammagraphy with 99mTc-Gluthatione and 99mTc-MIBI in the evaluation and staging of lymphoma

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Perera Pintado, Alejandro; Coca Perez, Marco A.; Batista Cuellar, Juan F.; Prats Capote, Anais; Sanchez Mendoza, Elvia; Sosa, Adriana; Mesa Cuervo, Jose R.; Hernandez Ramirez, Porfirio

    2004-01-01

    Full text: The aim of this study was to assess the utility of scintigammagraphy using 99mTc-MIBI and 99mTc-Gluthatione for the evaluation and staging of patients with lymphomas. We studied thirty patients (age range 16-66 years) of Hodgkin's disease (HD) and non-Hodgkin's lymphoma (NHL). A control group (CG) of 8 patients with negative histological results was also studied. The patients were divided in three groups; HD group: thirteen patients (7 males and 6 females); NHL: seventeen patients (10 males and 7 females); CG: eight patients (2 males and 6 females). Scintigammagraphy studies were performed 20 min and 2 h after intravenous administration of 925-1110 MBq of 99mTc-MIBI or 99mTc-Gluthatione (GSH) using a gamma camera (Sophy DS-7, Sopha Medical System, France) equipped with low energy all purpose parallel hole collimator. Anterior and posterior images of thorax, abdomen and pelvis in 128x128 pixels matrix each for 1 million counts per view were acquired. A 20% window centered on the 140 keV was used for all acquisitions. All images were processed and analysed on a workstation (Power Vision, SMV, Canada) and interpreted by three qualified and experienced nuclear medicine specialist. The final diagnosis was reached by consensus. The images with a focal abnormal intense uptake were considered positive. Images showing diffuse bilateral and symmetrical uptake, bilateral lung uptake and intestinal uptake were considered negative. The overall sensitivity, specificity and accuracy of results for both radiopharmaceuticals were calculated using the histological findings, x-ray, ultrasound and CT scanning as confirmation criterion as gold standard. The nodular sclerosis was the most frequent type in HD group. In this group twelve patients were positive with 99mTc-MIBI scintigammagraphy while one was negative (nodular sclerosis, grade II). Scintigammagraphy with 99mTc-GSH was positive in all patients in HD group. However, scintigammagraphy with both radiopharmaceuticals

  3. Neutral and stereospecific Tc-99m complexes: [99mTc]N-benzyl-3,4-di-(N-2-mercaptoethyl)-amino-pyrrolidines (P-BAT)

    International Nuclear Information System (INIS)

    Zhuang Zhiping; Ploessl, Karl; Kung Meiping; Mu Mu; Kung, Hank F.

    1999-01-01

    Technetium-99m-labeled radiopharmaceuticals are currently the most commonly used agents in nuclear medicine. To prepare binding site-specific small molecules containing a Tc-99m complexing core, it is important to consider a ligand system, which selectively forms only one stereoisomer. A novel series of bisaminoethanethiol (BAT) derivatives as a model system were prepared. Stereoisomers of N-benzyl-3,4-di-(N-2-mercaptoethyl)-amino pyrrolidines (P-BAT): (3R,4R)-P-BAT (R,R-4) and (3,4)meso-P-BAT (8), the trans and meso isomer, respectively, as a chelating group were prepared successfully. The desired Tc-99m P-BAT complexes were obtained by using Sn(II)/glucoheptonate as the reducing agent for [ 99m Tc]pertechnetate. As predicted, after complexation with [ 99m Tc]Tc v O, the trans isomer, (3R,4R)-P-BAT (R,R-4), showed only one isomer; whereas the corresponding meso isomer, (3,4)meso-P-BAT (8), produced two distinctive complexes isolated readily by high performance liquid chromatography (HPLC). The [ 99m Tc](R,S)meso-P-BAT (8) isomers showed a different lipophilicity (partition coefficient [P.C.]=54.3 and 55.4 for peak A and peak B, respectively), as compared with that of the corresponding [ 99m Tc](3R,4R)-P-BAT (R,R-4), trans isomer ( P.C.=163). Results of the biodistribution study in rats of these isomers show different heart and brain uptake, suggesting that the intrinsic differences in biodistribution are due to structural and stereospecific factors. Examples in this report confirm that it is possible to design stereospecific Tc-99m complexes based on the bisaminoethanethiol (N 2 S 2 , BAT) ligand system. Consideration on stereoselectivity of site-specific agents labeled with Tc-99m is likely an essential requirement on developing binding-site specific radiopharmaceuticals

  4. Liver scanning with sup(99m)Tc-phytate

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, A; Isobe, Y; Kobayashi, T; (Keio Univ., Tokyo (Japan). School of Medicine); Kinoshita, Fumio; Shibata, Masayoshi

    1975-03-01

    /sup 198/Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with /sup 198/Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with /sup 198/Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of /sup 198/Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease.

  5. Liver scanning with sup(99m)Tc-phytate

    International Nuclear Information System (INIS)

    Kubo, Atsushi; Isobe, Yoshinori; Kobayashi, Takeshi; Kinoshita, Fumio; Shibata, Masayoshi.

    1975-01-01

    198 Au-colloid has been widely used for liver scanning in Japan but it is not the best scanning agent because of the large exposure dose to the patient. The authors performed a few basic experiments with sup(99m)Tc-phytate, the preparation of which is very easy. The labeling efficiency was found to be 97.5% immediately after preparation and it remained fairly stable for a period of time. As a result, the compound can be used up to 6 hours after preparation without fear of chemical instability. Liver scanning with sup(99m)Tc-phytate was done on 116 patients and was compared with 198 Au-colloid liver-scanning. Scans made with sup(99m)Tc were found to be superior to those made with 198 Au in the resolution of surface defects in the liver, while at increasing depths the resolution with sup(99m)Tc dropped rapidly, apparently due to absorption of its relatively low energy photon. This indicates the importance of taking multidirectional views. The degrees of splenic concentration of sup(99m)Tc-phytate were fairly close to those of 198 Au-colloid. Therefore, liver scanning with sup(99m)Tc-phytate is useful in the diagnostic evaluation of diffuse parenchymal liver disease. (auth.)

  6. Evaluation of hepatic blood flow using 99mTc-GSA in rats with hepatic blood flow manipulation

    International Nuclear Information System (INIS)

    Hiraguchi, Etsuo

    1995-01-01

    Blood clearance and hepatic uptake parameters of 99m Tc-DTPA-galactosyl human serum albumin ( 99m Tc-GSA) were evaluated in two groups of rats, normal liver group and CCl 4 induced chronic liver injury group. In each group, four subgroups were classified as follows: simple laparotomy (LAP), hepatic artery ligation (HAL), portal vein ligation (PVL) and both hepatic artery and portal vein ligation (HAL+PVL). 99m Tc-GSA was intravenously injected (50 μg/100 g B.W.) to rats. Heart and liver were targetted as region of interest and time activity curves (TACs) were obtained. The blood clearance parameters (HH4 and Kd) and the hepatic uptake parameters (LHL4 and Ku) were calculated from these TACs. In normal liver group, the mean HH4 of LAP was significantly different from those of PVL and HAL+PVL. Similarly, the other three parameters (LHL4, Kd and Ku) of LAP were significantly different from those of PVL and HAL+PVL. CCl 4 induced chronic liver injury group showed significant difference on all four parameters in four subgroups. Hepatic tissue blood flow rates (HTBFR) calculated by Laser Doppler flowmeter correlated well with 99m Tc-GSA parameters in both groups. These results suggest that 99m Tc-GSA is useful to estimate hepatic blood flow not only in rats with normal liver, but also in rats with CCl 4 induced chronic liver injury. (author)

  7. {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD perform differently in typically hypoperfused areas in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Koulibaly, Pierre Malick [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Laboratoire de Biophysique, Universite de Nice-Sophia Antipolis, UFR de Medecine, 28 Avenue de Valombrose, 06107, Nice Cedex 2 (France); Nobili, Flavio; Vitali, Paolo; Girtler, Nicola; Rodriguez, Guido [Clinical Neurophysiology, Department of Internal Medicine, University of Genoa (Italy); Migneco, Octave; Darcourt, Jacques [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Robert, Philippe H. [Memory Center, Federation of Clinical Neuroscience, Centre Hospitalier Universitaire, University of Nice-Sophia Antipolis (France)

    2003-07-01

    Technetium-99m hexamethylpropylene amine oxime (HMPAO) and {sup 99m}Tc-N,N''-1,2-ethylene diylbis-l-cysteine diethyl ester dihydrochloride (ECD) yield significantly different images of cerebral perfusion owing to their particular pharmacokinetics. The aim of this study was to assess the topography, extension and statistical significance of these differences in Alzheimer's disease (AD). Sixty-four patients with mild to moderate AD were retrospectively selected by two European centres. Two series of patients, including 32 studied with {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and 32 studied with {sup 99m}Tc-ECD SPET, were matched for sex, age ({+-}3 years) and severity of cognitive impairment as assessed by the Mini-Mental State Examination (MMSE) ({+-}2 points), following a case-control procedure. SPET data were processed using SPM99 software (uncorrected height threshold: P=0.001). {sup 99m}Tc-ECD SPET gave significantly higher uptake ratio values than {sup 99m}Tc-HMPAO SPET in several symmetrical clusters, including the right and left occipital cuneus, the left occipital and parietal precuneus, and the left superior and middle temporal gyri. {sup 99m}Tc-HMPAO SPET gave significantly higher uptake ratio values than ECD in two smaller clusters, including the hippocampus in both hemispheres. In AD, relative brain uptake of {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is different in several brain regions, some of which are typically involved in AD, such as the precuneus and the hippocampus. These differences confirm the need for specific normal databases, but their impact on routine SPET reports in AD is not known and deserves an ad hoc investigation. (orig.)

  8. Pharmacokinetic model of myocardial 99mTc-sestamibi washout

    International Nuclear Information System (INIS)

    Watanabe, Tsubasa; Monzen, Hajime; Mizowaki, Takashi; Hiraoka, Masahiro; Hara, Masatake

    2013-01-01

    Technetium-99m sestamibi ( 99m Tc-MIBI) scintigraphy has been reported to be a functional imaging tool for in vivo detection of mitochondrial dysfunction in myocardium and multidrug resistance-associated protein expression in tumors. The purpose of this study was to propose a clinically applicable pharmacokinetic model with metabolic equilibrium of 99m Tc-MIBI and to evaluate the accuracy of the model. For this study, eight healthy men received 99m Tc-MIBI scintigraphy. The planar images were obtained at 0.25, 0.5, 1, 2, 3, 4, 5, and 6 h after 99m Tc-MIBI injection. The measured time series 99m Tc-MIBI counts were fitted to our model by nonlinear regression analysis. The predictive performance of the model was determined by comparing the residuals between measured and predicted values. We obtained a good regression by fitting data from 0.25 to 6 h after 99m Tc-MIBI injection, with excellent correlation between measured and predicted 99m Tc-MIBI counts (R 2 =0.9792) and a slope near unity. The 95% confidence interval of the mean prediction error included 0, which means that the prediction was not significantly biased. The precision of the prediction was also excellent. Our model shows good predictive capacity, with favorable bias and accuracy. By comparing the predictive values of this model with measured values, mitochondrial 99m Tc-MIBI washout can be quantified. 99m Tc-MIBI washout rates are reported to be a promising method for evaluating cardiac function in patients with cardiac diseases and P-glycoprotein expression in tumor cells. Therefore, this quantification could be useful for mitochondrial functional imaging, especially in patients with cardiac diseases or tumors. (author)

  9. Biodistribution of immunoliposome labeled with Tc-99m in tumor xenografted mice

    International Nuclear Information System (INIS)

    Kitamura, Naoto; Shigematsu, Naoyuki; Nakahara, Tadaki; Kanoh, Momoe; Hashimoto, Jun; Kunieda, Etsuo; Kubo, Atsushi

    2009-01-01

    Immunoliposome (PEG, GAH, liposome; PGL), consisting of F(ab') 2 fragment of monoclonal antibody, GAH and polyethyleneglycol-coated (PEGylated) liposome was provided. Immunoliposome, PGL was labeled with technetium-99m (Tc-99m) by two methods: labeling F(ab') 2 fragment with Tc-99m; Tc-99m-PGL, and entrapping Tc-99m into liposome; PGL[Tc-99m]. The objective of this study was to compare the biodistribution of Tc-99m-PGL and PGL[Tc-99m] in human gastric cancer xenografted mice. Tc-99m-PGL, PGL[Tc-99m], and Tc-99m-entrapped liposome; Lipo[Tc-99m] were prepared. They were injected into human gastric cancer, MKN45, xenografted mice via the tail vein, and their biodistribution was studied. No marked accumulation of either PGL[Tc-99m] or Lipo[Tc-99m] was observed in the stomach. The uptake of Tc-99m-PGL by the liver, spleen, and lung was higher than that by the tumor. On the other hand, the uptake of PGL[Tc-99m] by the lung and spleen was markedly lower as compared with that of Tc-99m-PGL; the accumulation of PGL[Tc-99m] was lower in the lung and higher in the spleen as compared with that of the tumor. Although the liver uptake of PGL[Tc-99m] was markedly decreased as compared with that of Tc-99m-PGL, it was higher than the uptake of the tumor. The Tc-99m-PGL was strongly taken up by the tumor, with a high level of incorporation also seen in the stomach. These findings suggest the need for further study of the labeling stability. PGL[Tc-99m] appears to show promise for high tumor uptake and retention. This is an important implication for the potential application of immunoliposomes entrapped with Re-186, instead of Tc-99m, in internal radiotherapy. (author)

  10. Influence of bilirubin on the distribution of 99mTc-HIDA and 99mTc-IODIDA in rats and their interaction with HSA

    International Nuclear Information System (INIS)

    Jovanovic, M.S.; Zmbova, B.; Zivanov-Stakic, D.; Vladimirov, S.

    1993-01-01

    The interaction of bilirubin and 99m Tc-HIDA and 99m Tc-IODIDA has been studied in rats. The mechanism of this interaction has been examined at the level of binding with human serum albumin (HSA) by the in vitro method. Percentage of binding with HSA, and affinity constants for 99m Tc-IODIDA were determined with and without bilirubin. Bilirubin was labeled with 99m Tc and its interaction with HSA was also examined. (author) 8 refs.; 2 figs.; 4 tabs

  11. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  12. Clinical evaluation of myocardial perfusion imaging with 99mTc-CPI

    International Nuclear Information System (INIS)

    Liu Xiujie

    1988-01-01

    10 normal subjects and 55 cases of patients with heart diseases were studied with 99m Tc-CPI myocardial perfusion imaging. The 99m Tc-CPI myocarbial imaging is superior to 99m Tc-TBI, because the uptake of 99m Tc-CPI in both lung and liver is lower. The imaging quality of 99m Tc-CPI is nearly as good as that of 201 Tl. 16 patients had both 99m Tc-CPI myocardial imaging and coronary artery angiography. The sensitivity of 99m Tc-CPI myocardial imaging for detecting coronary artery disease (CAD) was 92%, whereas the sensitivity of ECG was 84.6%. 99m Tc-CPI myocardial tomography was obtained in 17 patients using Toshiba 90B SPECT system. The imaging quality of myocardial tomography using 99m Tc-CPI is very good and superior to planar imaging for detecting myocardial infarction

  13. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  14. '99Mo/99mTc Generator Based on High Radionuclidic Pure Zirconium Molybdate Gel

    International Nuclear Information System (INIS)

    Amin, M.; Mostafa, M.; El-Amir, M.A.; El-Absy, M.A.; Mohamed, O.I.; Farag, A.B.

    2014-01-01

    99 Mo / 99 mTc radioisotope generator was prepared using in-situ precipitated zirconium molybdate chromatographic column. Zirconium molybdate gel matrix was synthesized by precipitation of neutron activation molybdenum-99 from its solution after variety purification processes to prevent contamination of the 99m Tc eluate with cross-contaminants. Greeter than 82.7 ± 0.4 % of the generated 99m Tc was immediately and reproducible eluted by passing 10 ml 0.9 % NaCl solution through the 1 g zirconium molybdate- 99 Mo column matrix at a flow rate of 0.5 ml / min and room temperature with high chemical, radionuclide ( ≥ 99.9 % 99m Tc) and radiochemical purity ( ≥ 97.7 % % as 99 mTcO 4 - ) with ph value suitable for medical uses.

  15. 99m-technetium tetrofosmin and 99mTc-methylene diphosphonate in pre-surgical breast cancer

    International Nuclear Information System (INIS)

    Piperkova, E.; Gavrilov, I.; Timcheva, K.; Garanina, Z.; Aleksandrova, E.; Katerinski, K.; Dimitrova, M.

    2004-01-01

    Full text: The aim of this study was to assess the role of the Tc-99m Tetrofosmin (TF) in conjunction with Tc-99m methylenediphosphonate (MDP) in pre-surgical breast cancer (BC) staging. Thirty-six female patients, age range was 32-70 years (average 51.45 years), where the clinical examination, mammography (MG) and fine-needle aspiration cytology were inconclusive were subjected to Tc-99m TF Scintimammography (SMM). All the patients were examined in a specialized breast clinic by experienced surgeons and radiologists. Of the 36 patients, 24 had hyperdense breasts, 8 had undergone lumpectomy or mastectomy due to cancer in one of the breasts and were included in the present study because of suspicion of lesion in the contra lateral breast, 2 had palpable axillary lymph nodes (LN) but no palpable breast lump and 2 patients were of mastitis carcinomatosis. All biopsies were histopathologically verified 740 MBq of Tc-99m TF (Myoview-Amersham) was injected in the arm opposite to the side of the breast lesion. In patients with bilateral breast lesions (BL) radiopharmaceutical was injected in a pedal vein. Planar imaging in prone position was done 10-15 min later. Two lateral views of the left and right breasts including axilla were acquired followed by an anterior view in supine position with arm in an upright position so as to include both breasts and axillary region in the field of imaging view. Imaging was done using a large field of view single-head gamma camera (Diacam-Siemens) coupled with low-energy high-resolution collimator. In patients with locally advanced BC who were to receive pre-operative neo-adjuvant chemotherapy, cardiac GATED SPECT was also acquired using standard protocol. After few days, Tc-99m MDM scintimammography and whole-body bone scintigraphy was also performed. SMM, using the same acquisition protocol as with 99mTc-TF, was done 5-10 min after intravenous injection of 555-740 MBq 99mTc MDP. Standard WBBS was acquired two to three hours later. SMM

  16. Influence of a {sup 99m}TcN core on the biological and physicochemical behavior of {sup 99m}Tc complexes of L,L-EC and L,L-ECD

    Energy Technology Data Exchange (ETDEWEB)

    Mangera, Kennedy O; Vanbilloen, Hubert P.; Bellande, Emmanuel; Pasqualini, Roberto; Verbruggen, Alfons M

    1996-11-01

    {sup 99m}Tc-nitrido complexes of L,L-ethylene dicysteine ({sup 99m}TcN-L,L-EC) and {sup 99m}TcN-L,L-ethylene dicysteine diethylester ({sup 99m}TcN-L,L-ECD) were prepared and their characteristics compared to those of the respective {sup 99m}Tc-oxo complexes. {sup 99m}TcN-L,L-EC and {sup 99m}TcO-L,L-EC migrate to similar extents during electrophoresis at pH 12, but, at pH 6, {sup 99m}TcN-L,L-EC migrates further than {sup 99m}TcO-L,L-EC. Renal excretion of {sup 99m}TcN-L,L-EC is inferior to that of {sup 99m}TcO-L,L-EC, indicating that the TcN-glycine sequence has lower affinity for the renal tubular system. Both {sup 99m}TcO-L,L-ECD and {sup 99m}TcN-L,L-ECD are neutral, but {sup 99m}TcN-L,L-ECD is hydrophilic and shows minimal brain uptake in both mice and the baboon.

  17. Development of Tc99m-Saccharic Acid for Heart Imaging

    International Nuclear Information System (INIS)

    Shafii Khamis; Mohd Azfar Adenan; Bohari Yaacob; Amir Fitri Shafii

    2014-01-01

    Cardiovascular disease especially the coronary heart disease (CHD) is the leading cause of death worldwide. Coronary heart disease is a common term for the buildup of plaque in the heart coronary arteries that could block the blood supply to the myocardial and this could lead to heart attack. An estimated 17 million people died from cardiovascular disease in 2008 representing 30% of all global death. In United Kingdom, coronary heart disease killed as much as 82,000 people each year. Hence, early detection of the coronary heart disease is very important in reducing the mortality among the world population. One of the most sensitive detection methods is by radioimaging using Technetium-99m radiopharmaceuticals. Several different radio imaging agents such as Tc99m radiopharmaceutical were developed as radiagnostic agent in determining the CHD especially in identifying the blockage of the coronary artery of the heart muscle. Despite the success of Tc99m-sestamibi and Tc99m-tetrofosmin as effective agents for myocardial perfusion study, the search for other Tc99m heart imaging agents has never been interrupted. This report described the formulation of the Tc99m-saccharic acid radiopharmaceutical kit, radiolabelling of the kit, radiochemical purity evaluation of the Tc99m labeled saccharaic acid, and animal study involving radio imaging using gamma camera. The animal are then sacrificed and the biological distribution of the Tc99m-saccharic acid in-vivo was determined. Comparative study was also conducted using commercially available Tc99m-tetrafosmin, a CHD radiopharmaceutical kit. The Tc99m-saccharic acid developed gave a very high labeling efficiency of >92% with Tc99m and good uptake in the heart muscle. The saccharic acid kit developed was also found to be comparable in quality to the commercially available Tc99-tetrafosmin kit. (author)

  18. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Sabine [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany); Rennen, Huub J.; Boerman, Otto C. [Radboud University, Nijmegen Medical Centre, 6500 HB Nijmegen (Netherlands); Baumann, Sabine; Cyr, John E.; Manchanda, Rajesh; Lister-James, John [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany); Corstens, Frans C. [Radboud University, Nijmegen Medical Centre, 6500 HB Nijmegen (Netherlands); Dinkelborg, Ludger M. [Bayer Schering Pharma AG, Global Drug Discovery, D-13342 Berlin (Germany)], E-mail: sabine.krause@bayerhealthcare.com

    2007-11-15

    Background: The technetium 99 m ({sup 99m}Tc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [{sup 99m}Tc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [{sup 99m}Tc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [{sup 99m}Tc]P483H images were equivalent to those obtained with {sup 111}In ex vivo labeled leukocytes. However, there was physiologic accumulation of radioactivity in the body that could hamper interpretation of the images. In this study, the potential of [{sup 99m}Tc]P1827DS for infection imaging was assessed in comparison with [{sup 99m}Tc]P483H and the well-described imaging agent [{sup 99m}Tc] hydrazinonicotinamide (HYNIC)-interleukin 8 (IL-8). Methods: The binding of [{sup 99m}Tc]P1827DS to human blood cell was studied in vitro. A rabbit Escherichia coli infection model was used to perform the biodistribution and imaging studies with [{sup 99m}Tc]P1827DS, [{sup 99m}Tc]P483H and [{sup 99m}Tc]HYNIC-IL-8. Results: [{sup 99m}Tc]P1827DS binds to leukocytes but not to erythrocytes. The leukocyte binding was not saturable up to an investigated concentration of 10 {mu}M. The accumulation of [{sup 99m}Tc]P1827/DS at the infection site strongly depends on the P1827/DS ratio and was optimal at a molar ratio of 10:1. [{sup 99m}Tc]P1827DS shows improved biodistribution over [{sup 99m}Tc]P483H with similar uptake at the infection site. Abscess uptake of [{sup 99m}Tc]HYNIC-IL-8 was approximately three times higher than that of [{sup 99m}Tc]P1827DS. [{sup 99m}Tc]HYNIC-IL-8 showed high accumulation in the kidneys, whereas [{sup 99m}Tc]P1827DS showed high lung uptake and slightly higher accumulation in the liver and spleen. Conclusion: [{sup 99m}Tc]P1827DS is a potential new inflammation imaging agent, which clearly visualized the abscess in the rabbit E. coli infection model and showed improved biodistribution compared to [{sup 99m}Tc]P483H. However, the infection uptake and biodistribution of

  19. Preclinical evaluation of technetium 99m-labeled P1827DS for infection imaging and comparison with technetium 99m IL-8

    International Nuclear Information System (INIS)

    Krause, Sabine; Rennen, Huub J.; Boerman, Otto C.; Baumann, Sabine; Cyr, John E.; Manchanda, Rajesh; Lister-James, John; Corstens, Frans C.; Dinkelborg, Ludger M.

    2007-01-01

    Background: The technetium 99 m ( 99m Tc)-radiolabeled, leukocyte-avid peptide-glycoseaminoglycan complex, [ 99m Tc]P1827DS, has been synthesized as an improved infection/inflammation imaging agent to [ 99m Tc]P483H (LeukoTect, Diatide). In a phase I/II clinical trail, [ 99m Tc]P483H images were equivalent to those obtained with 111 In ex vivo labeled leukocytes. However, there was physiologic accumulation of radioactivity in the body that could hamper interpretation of the images. In this study, the potential of [ 99m Tc]P1827DS for infection imaging was assessed in comparison with [ 99m Tc]P483H and the well-described imaging agent [ 99m Tc] hydrazinonicotinamide (HYNIC)-interleukin 8 (IL-8). Methods: The binding of [ 99m Tc]P1827DS to human blood cell was studied in vitro. A rabbit Escherichia coli infection model was used to perform the biodistribution and imaging studies with [ 99m Tc]P1827DS, [ 99m Tc]P483H and [ 99m Tc]HYNIC-IL-8. Results: [ 99m Tc]P1827DS binds to leukocytes but not to erythrocytes. The leukocyte binding was not saturable up to an investigated concentration of 10 μM. The accumulation of [ 99m Tc]P1827/DS at the infection site strongly depends on the P1827/DS ratio and was optimal at a molar ratio of 10:1. [ 99m Tc]P1827DS shows improved biodistribution over [ 99m Tc]P483H with similar uptake at the infection site. Abscess uptake of [ 99m Tc]HYNIC-IL-8 was approximately three times higher than that of [ 99m Tc]P1827DS. [ 99m Tc]HYNIC-IL-8 showed high accumulation in the kidneys, whereas [ 99m Tc]P1827DS showed high lung uptake and slightly higher accumulation in the liver and spleen. Conclusion: [ 99m Tc]P1827DS is a potential new inflammation imaging agent, which clearly visualized the abscess in the rabbit E. coli infection model and showed improved biodistribution compared to [ 99m Tc]P483H. However, the infection uptake and biodistribution of [ 99m Tc]P1827DS is not superior to that of [ 99m Tc]HYNIC-IL-8 in this animal model

  20. Evaluation of glomerular filtration rate of 99mTc-DTPA using PIP software

    International Nuclear Information System (INIS)

    Opazo, C.; Troncoso, M.; Gutierrez, E.; Guerrero, B.; Mena, J.

    2002-01-01

    Aim: Our purpose is to compare the measurement of glomerular filtration rate by DTPA Renogram (DTPA-GFR) using PIP software with those by 24-hour creatinine clearance (CC) in order to evaluate the results provided for the procedure and the software we used. The need for using this method well known from earlier eighties raised from the practical difficulties in getting an accurate CC in pediatric population specially in out patients as well as the fact there is not radiation, time, morbidity or discomfort added to the renogram. Methods: In a prospective study running from Sep-2001, up to now 18 patients aged 1 to 18 years underwent DTPA Renogram. DTPA-GFR was calculated from the renogram in a computer and PIP software system developed for the IAEA to be attached to analogical gammacameras The procedure involves 30 minutes DTPA renogram, full and empty DTPA syringe activity measure, input patient height and weight, to make ROIs around kidneys and background ROIs drawn below and in the lateral side of both kidneys. The results are provided automatically for the software using a kidney uptake index with Gates method. The results are expressed in ml/min for both and each kidney separately. No blood samples were used. All patients had CC measurement done at most 48 hours from the renogram using 24 hours urine collection and serum creatinine level. We make sure patients were well hydrated orally before starting renogram acquisition. Results: The DTPA-GFR mean was 81.6 ml/min (22.5-153.6). The CC mean was 78.8 ml/min (14.8-132). The comparison between DTPA-GFR and CC measurements showed an acceptable R2 coefficient (0.9228), a slope close to identity line (0.9504). The intercept was 6.75 ml/min and the T value was 0.2983. Conclusion: We have found an acceptable correlation between DTPA-GFR and CC with results obtained up to now. DTPA-GFR is a very easy procedure adding no extra time or cost to the renogram. The information provided can be useful to be considered by the

  1. Evaluation of 99mTc(CO)5I as a potential lung perfusion agent

    International Nuclear Information System (INIS)

    Miroslavov, Alexander E.; Gorshkov, Nikolay I.; Lumpov, Alexander L.; Yalfimov, Anatoly N.; Suglobov, Dmitrii N.; Ellis, Beverley L.; Braddock, Rattana; Smith, Anne-Marie; Prescott, Mary C.; Lawson, Richard S.; Sharma, Harbans L.

    2009-01-01

    Introduction: The use of 99m Tc-macroggregated albumin for lung perfusion imaging is well established in nuclear medicine. However, there have been safety concerns over the use of blood-derived products because of potential contamination by infective agents, for example, Variant Creutzfeldt Jakob Disease. Preliminary work has indicated that Tc(CO) 5 I is primarily taken up in the lungs following intravenous administration. The aim of this study was to evaluate the biodistribution and pharmacokinetics of 99m Tc(CO) 5 I and its potential as a lung perfusion agent. Methods: 99m Tc(CO) 5 I was synthesized by carbonylation of 99m TcO 4- at 160 atm of CO at 170 deg. C in the presence of HI for 40 min. Radiochemical purity was determined by HPLC using 99 Tc(CO) 5 I as a reference. 99m Tc(CO) 5 I was administered by ear-vein injection to three chinchilla rabbits, and dynamic images were acquired using a gamma camera (Siemens E-cam) over 20 min. Imaging studies were also performed with 99m Tc-labeled macroaggregated albumin ( 99m Tc-MAA) and 99m TcO 4- for comparison. 99m Tc(CO) 5 I was administered intravenously to Sprague-Dawley rats, and tissue distribution studies were obtained at 15 min and 1 h postinjection. Comparative studies were performed using 99m Tc-MAA. Results: Radiochemical purity, assessed by HPLC, was 98%. The retention time was similar to that of 99 Tc(CO) 5 I. The dynamic images showed that 70% of 99m Tc(CO) 5 I appeared promptly in the lungs and remained constant for at least 20 min. In contrast, 99m TcO 4- rapidly washed out of the lungs after administration. As expected 99m Tc-MAA showed 90% lung accumulation. The percentage of injected dose per gram of organ ±S.D. at 1 h for 99m Tc(CO) 5 I was as follows: blood, 0.22±0.02; lung, 12.8±2.87; liver, 0.8±0.15; heart, 0.15±0.01; kidney, 0.47±0.08. The percentage of injected dose per organ ±S.D. at 1 h was as follows: lung, 22.47±2.31; liver, 10.53±1.8; heart, 0.18±0.01; kidney, 1.2±0.17. Tissue

  2. Preparation, quality control and biological characterization of 99mTc-vincristine

    International Nuclear Information System (INIS)

    Saira Hina; Muhammad Ibrahim Rajoka; Asma Haque

    2015-01-01

    In present study it is aimed to radiolabel vincristine with 99m Tc and to evaluate bioaffinity of 99m Tc labeled vinc. The optimum conditions required to obtain 99.6 ± 0.4 %, (n = 5) radiolabeling yield of 99m Tc-vincristine ( 99m Tc-vinc) were as follows: pH 4, 5 µg of vincristine sulphate, 6 µg SnCl 2 ·2H 2 O as a reducing agent and 10 min incubation time at room temperature. Quality control of 99m Tc-vinc was done by using paper electrophoresis and thin layer chromatography. The radiolabeling yield was confirmed by High performance liquid chromatography using radioactive and UV detector operating at 230 nm. 99m Tc-vinc was stable in vitro for 5 h. Biodistribution and scintigraphy of 99m Tc-vinc was performed in mice and rabbits respectively and that 99m Tc-vinc showed high uptake of it in liver and spleen. Finally 99m Tc-vinc may be the potential imaging agent for liver and spleen. (author)

  3. Can tumor uptake Tc-99m MDP

    International Nuclear Information System (INIS)

    Yang, Y.S.F.; Zeng, Z.J.; Yao, Y.M.; Shi, S.M.P.; Shi, S.Z.Y.

    2002-01-01

    Aim: To study a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines (SPC-A1 adenocarcinoma of lung cancer, P37 Breast cancer, T24 Bladder cancer, SKOV2 Ovary carcinoma, Hela-229 Cervical carcinoma, Osteosarcoma, A375 Melanoma) and one mouse lung cancer cell line (Lewis). They were transplanted into 13, 4, 5, 5, 4, 5 athymic mice, 6 SCID nude mice and 4 C57 black mice, respectively. Approximately 10(7) cells of each cell line were injected subcutaneously into a right chest of mouse. After 5∼6 weeks, the Tc-99m MDP scintigraphy were determined 5-6 hours after i.v. injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. Region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left chest or spine of mice in Tc-99m MDP imaging and the average count ratio (tumor to background ratio: T/B, tumor to spine ratio: T/NT) in each ROI was calculated. 13 nude mice bearing the adenocarcinoma (SPC-A1) were sacrificed and biodistribution was determined after Tc-99m MDP scintigraphy. Results were expressed as % injected dose/gram (%ID/g), mean±SD. T-ulcer=ulcer of tumor, T-round=surrounding of tumor, T-center=the center of tumor, Thor-sp=thoracic spine, Lum-ver=lumbar vertebra, LN=lymph node. Conclusions: Tumor can uptake Tc-99m MDP including adenocarcinoma. Higher uptake rate in the center tissue of tumor is than other part of tumor. It maybe connected with necrosis or fibrosis of tumor

  4. Potential Ways to Address Shortage Situations of 99Mo/99mTc.

    Science.gov (United States)

    Filzen, Leah M; Ellingson, Lacey R; Paulsen, Andrew M; Hung, Joseph C

    2017-03-01

    99m Tc, the most common radioisotope used in nuclear medicine, is produced in a nuclear reactor from the decay of 99 Mo. There are only a few aging nuclear reactors around the world that produce 99 Mo, and one of the major contributors, the National Research Universal (Canada), ceased production on October 31, 2016. The National Research Universal produced approximately 40% of the world's 99 Mo supply, so with its shut down, shortages of 99 Mo/ 99m Tc are expected. Methods: Nuclear pharmacies and nuclear medicine departments throughout the United States were contacted and asked to provide their strategies for coping with a shortage of 99 Mo/ 99m Tc. Each of these strategies was evaluated on the basis of its effectiveness for conserving 99m Tc while still meeting the needs of the patients. Results: From the responses, the following 6 categories of strategies, in order of importance, were compiled: contractual agreements with commercial nuclear pharmacies, alternative imaging protocols, changes in imaging schedules, software use, generator management, and reduction of ordered doses or elimination of backup doses. Conclusion: The supply chain of 99 Mo/ 99m Tc is quite fragile; therefore, being aware of the most appropriate coping strategies is crucial. It is essential to build a strong collaboration between the nuclear pharmacy and nuclear medicine department during a shortage situation. With both nuclear medicine departments and nuclear pharmacies implementing viable strategies, such as the ones proposed, the amount of 99m Tc available during a shortage situation can be maximized. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  5. Tc-99m Glu-Cys-Gly-His-Gly-Lys (ECG-HGK), a novel Tc-99m labeled hexapeptide for molecular tumor imaging.

    Science.gov (United States)

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    Domain 5 of kinin-free high molecular weight kininogen inhibits the adhesion of many tumor cell lines, and it has been reported that the histidine-glycine-lysine (HGK)-rich region might be responsible for inhibition of cell adhesion. The authors developed HGK-containing hexapeptide, glutamic acid-cysteine-glycine (ECG)-HGK, and evaluated the utility of Tc-99m ECG-HGK for tumor imaging. Hexapeptide, ECG-HGK was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling efficiency was evaluated. The uptake of Tc-99m ECG-HGK within HT-1080 cells was evaluated in vitro. In HT-1080 tumor-bearing mice, gamma imaging and biodistribution studies were performed. The complexes Tc-99m ECG-HGK was prepared in high yield. The uptake of Tc-99m ECG-HGK within the HT-1080 tumor cells had been demonstrated by in vitro studies. The gamma camera imaging in the murine model showed that Tc-99m ECG-HGK was accumulated substantially in the HT-1080 tumor (tumor-to-muscle ratio = 5.7 ± 1.4 at 4 h), and the tumoral uptake was blocked by the co-injection of excess HGK (tumor-to-muscle ratio = 2.8 ± 0.6 at 4 h). In the present study, Tc-99m ECG-HGK was developed as a new tumor imaging agents. Our in vitro and in vivo studies revealed specific function of Tc-99m ECG-HGK for tumor imaging. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin combined with SPECT technique in patients with secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Botushanova, A.; Yaneva, M.; Botushanov, N.

    2015-01-01

    Full text: Preoperative parathyroid scintigraphy is highly beneficial when used for minimally invasive parathyroidectomy. The aim is to examine the diagnostic value of single isotope dual-phase scintigraphy with 99mTc-MIBI and 99mTc-etrofosmin combined with SPECT technique in preoperative localization of hyperplastic parathyroid glands in patients with secondary hyperparathyroidism. The study included 15 patients aged 37 to 73 years (8 women and 7 men) with proven secondary hyperparathyroidism with increased serum calcium and parathyroid hormone. All patients were on chroniodialysis and treatment with Calcitriol. The examination was done with two-headed SPECT gamma camera SIMBIA by protocol for single isotope dual-phase scintigraphy and SPECT technique. 740 MBq 99mTc-MIBI were applied intravenously in 6 of the patients, and in 9 patients were administered 740 MBq 99mTc-tetrofosmin. The scintigraphy with 99mTc-MIBI visualized a focus of residual activity in 4 patients, and in 2 we received negative scintigraphy. The scintigraphy with 99mTc-tetrofosmin combined with SPECT showed an area of hyperfixation in both phases on SPECT images in 1 patient. In 2 patients hyperfixating areas suspicious for abnormal parathyroid glands were registered only in the early SPECT images. In 6 patients the scintigraphic results were negative. Negative scintigraphic results can be explained with the ability to suppress the uptake of 99mTc-MIBI and 99mTc - tetrofosmin by the parathyroid cells as a result of taking Calcitriol. Scintigraphy with 99mTc-MIBI and 99mTc-tetrofosmin did not show high sensitivity in identifying the hyperplastic parathyroid glands, although it was capable to distinguish patients with nodular hyperplasia of those with diffuse hyperplasia

  7. Clinical use of 99mTc mebrofenin

    International Nuclear Information System (INIS)

    Chen Shaoliang; Zhao Huiyang

    1989-01-01

    A study of 124 subjects was undertaken to evaluate the image patterns of 99m Tc trimethylbromo iminodiacetic acid ( 99m Tc mebrofenin) in hepatobiliary disorders. It exhibits: (a) high specificity for the hepatobiliary system with low urinary excretion rate; (b) high competition to bilirubin; and (c) clearing more rapidly from the blood and rapid transit through the hepatobiliary system. Therefore 99m Tc mebrofenin result in the best visualization of the biliary system either in nonjaundiced or joundiced patient, and the hepatobiliary system can be clearly visualized even in patients with serum bilirubin level up to 30 mg%. The major drawback of this agent is that the urinary excretion rate increased in case of high serum bilirubin

  8. Synthesis and evaluation of 99mTc/99Tc-MAG3-biotin conjugates for antibody pretargeting strategies

    International Nuclear Information System (INIS)

    Gog, Frank B. van; Visser, Gerard W.M.; Gowrising, Radjish W.A.; Snow, Gordon B.; Dongen, Guus A.M.S. van

    1998-01-01

    Four 99m Tc-MAG3-biotin conjugates were synthesized to determine their potential use in antibody pretargeting strategies for radioimmunoscintigraphy (RIS). To use these 99m Tc-MAG3-biotin conjugates as model compounds for 186 Re-MAG3-biotin conjugates for radioimmunotherapy (RIT), nanomolar amounts of 99 Tc were added as carrier to 99m Tc. The biotin derivatives used for the preparation of the conjugates - biocytin, biotin hydrazide, biotinyl-piperazine, and biotinyl-diaminosuccinic acid - differed at the site that is regarded to be susceptible to hydrolysis by biotinidase present in human plasma. All four conjugates were produced with high radiochemical purity, were stable in PBS, and demonstrated full binding capacity to streptavidin. The 99m Tc/ 99 Tc-MAG3-labeled biotinyl-piperazine and biotinyl-diaminosuccinic acid conjugates were stable in mouse as well as human plasma, whereas the corresponding biocytin and biotin hydrazide conjugates were rapidly degraded. The biodistribution in nude mice at 30 min after injection was similar for all conjugates, and a rapid blood clearance and high intestinal excretion were both observed. It is concluded that the metabolic routing of a conjugate containing biotin and MAG3 is dominated by these two moieties. For this reason, MAG3-biotin conjugates do not seem suited for pretargeted RIT, for which quantitative and fast renal excretion is a prerequisite to minimize radiation toxicity. However, in a pretargeted RIS approach the 99m Tc-MAG3-biotin conjugates might have potential

  9. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Zhuang, Hongming; Wang, Zhenghua; Tian, Jian; Xing, Xiaoping; Jin, Jin; Zhong, Dingrong; Zhang, Jingjing

    2013-11-01

    Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  10. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan

    International Nuclear Information System (INIS)

    Jing, Hongli; Li, Fang; Zhuang, Hongming; Wang, Zhenghua; Tian, Jian; Xing, Xiaoping; Jin, Jin; Zhong, Dingrong; Zhang, Jingjing

    2013-01-01

    Purpose: Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Methods: Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Results: Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Conclusions: Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO

  11. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan

    Energy Technology Data Exchange (ETDEWEB)

    Jing, Hongli, E-mail: annsmile1976@sina.com [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Li, Fang, E-mail: lifang@pumch.cn [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Zhuang, Hongming, E-mail: zhuang@email.chop.edu [Department of Radiology, The Children' s Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, 34th and Civic Ctr Blvd, Philadelphia, PA 19104 (United States); Wang, Zhenghua, E-mail: ccq1214@yahoo.com.cn [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Tian, Jian, E-mail: tianjian4809@hotmail.com [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Xing, Xiaoping, E-mail: xingxp@126.com [Department of Endocrinology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Jin, Jin, E-mail: jinjin9010@126.com [Department of Orthopedic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Zhong, Dingrong, E-mail: ZhongDR@pumch.cn [Department of Pathology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China); Zhang, Jingjing, E-mail: zhangjingjingtag@163.com [Department of Nuclear Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730 (China)

    2013-11-01

    Purpose: Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Methods: Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Results: Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Conclusions: Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO.

  12. Synthesis and formulation of {sup 99m} Tc-ECD radiopharmaceutical; Sintesis y formulacion del radiofarmaco {sup 99m} Tc-ECD

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo G, B E

    1998-06-01

    Nuclear medicine is a medical specialty which uses radioactive compounds (radionuclides) for diagnostic and therapeutic purposes. {sup 99m} Tc is the more common radionuclide used in many studies in nuclear medicine because its advantages: it has a photopeak of 140 KeV and a half-life of 6 hours; it can be eluted from a Molybdenum 99 generator, so radiopharmaceuticals can be prepared on site. Ethyl cysteine dimer (ECD) labelled with reduced Technetium 99m has been purposed recently as a promising radiopharmaceutical for brain perfusion imaging {sup 99m} Tc-ECD is a lipophilic neutral complex which cross the brain blood barrier and show high brain uptake. The objective of this work was synthesize and to design a freeze dried formulation for the instant preparation of {sup 99m} Tc-ECD complex useful for brain perfusion imaging. We obtained a freeze dried stable formulation for the preparation of {sup 99m} Tc-ECD kit with a radiochemical purity higher than 90 %, which fulfills with the quality control of radiopharmaceuticals. Furthermore, we developed analytic techniques for the determination of the different chemical compounds into the lyophilized kit. (Author).

  13. 99mTc-Dextran-70: preparation and quality control

    International Nuclear Information System (INIS)

    Herrerias, Rosana; Muramoto, Emiko; Hamada, Elena S.; Barboza, Marycel F. de; Silva, Constancia P.G. da

    1997-01-01

    Dextran-70 labelled with 99m Tc is used for lymphocintigraphy in Nuclear Medicine. The aims of this work were: the lyophilized kit formulation; the radiochemical quality control determination and the biodistribution studies in Wistar rats. Each lyophilized vial contains: 50 mg Dextran-70 (Sigma); 750 μg Sn Cl 2 . 2 H 2 O, pH = 4.0. For the radiochemical determination the following parameters were assayed: Chromatography systems (Whatman 3MM, TLC-SG (Silica-gel) e TLC-A1 (aluminium); the 99m Tc activities (37, 111 and 1850 MBq); the 99m Tc volumes (1,3,5 and 8 mL) and the stability after the lyophilization process (1, 3, 6, 12 and 24 months). The Whatman 3MM chromatography system using acetone as solvent presented a purity yield of 99.88; 99.70; 99.00 and 98.92% using 1, 3, 5 and 8 mL of 99m Tc, respectively. The yield of labelling showed 99.80 % of radiochemical purity using 1850 MBq of 99m Tc, after 24 months. The biological studies were performed in Wistar rats, average weight 250g, after intravenous administration of 99m Tc-Dextran-70 (2.96 MBq). A slow blood decrease with high hepatic uptake was mesured. The high kidney uptake observed, during the experiment, was due the experiment, was due the fact that the animals were kept under anaesthesic effect. (author). 4 refs., 2 figs., 4 tabs

  14. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Vilcek, S; Machan, V; Kalincak, M [Ustav Radioekologie a Vyuzitia Jadrovej Techniky, Kosice (Czechoslovakia); Nicak, A [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1981-04-30

    Experiments showed that the cumulation of technetium-99m following the administration of /sup 99m/Tc-Sn-pyrophosphate and s/sup 99m/Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum /sup 99m/Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of /sup 99m/Tc in the particular organs but also in the necrotic tissue of the myocardium.

  15. Effect of acidity and chemical composition of sup(99m)Tc-radiopharmaceuticals on sup(99m)Tc accumulation in necrotic tissue of rat myocardium

    International Nuclear Information System (INIS)

    Vilcek, S.; Machan, V.; Kalincak, M.; Nicak, A.

    1981-01-01

    Experiments showed that the cumulation of technetium-99m following the administration of sup(99m)Tc-Sn-pyrophosphate and sup(99m)Tc-Sn-oxytetracycline in the necrotic tissue of rat myocardium damaged by cauterization depended on the end pH value. The maximum sup(99m)Tc cumulation in the myocardial lesion was noted when the end pH value ranged in 5.5 to 6.0. It appeared that pyrophosphate concentration decrease below the critical limit not only affected the cumulation of sup(99m)Tc in the particular organs but also in the necrotic tissue of the myocardium. (author)

  16. Preparation of 99 sup(m)Tc labeled fibrinogen

    International Nuclear Information System (INIS)

    Almeida, M.A.T.M. de; Silva, C.P.G. da.

    1984-01-01

    A simple method for the preparation of 99 sup(m) TC labelled Fibrinogen using stannous chloride as reducing agent of 99 sup(m) TcO- 4 ion is presented. A sample of 20 mg of Fibrinogen is dissolved in 2 ml of buffer carbonate (pH=8) and 0.3 ml stannous chloride 0.2% is added. A sterile solution of sodium pertechnetate 99 sup(m) Tc eluted from a Mo-Tc generator is immediately added. The mixture rests for 30 minutes and after this period, the obtained yield is about 70%. The lyophilized kits also presented a yield of 70%, being therefore suitable for medical applications. (Author) [pt

  17. Bone turnover markers are correlated with total skeletal uptake of 99mTc-methylene diphosphonate (99mTc-MDP)

    International Nuclear Information System (INIS)

    Lenora, Janaka; Norrgren, Kristina; Thorsson, Ola; Wollmer, Per; Obrant, Karl J; Ivaska, Kaisa K

    2009-01-01

    Skeletal uptake of 99m Tc labelled methylene diphosphonate ( 99m Tc-MDP) is used for producing images of pathological bone uptake due to its incorporation to the sites of active bone turnover. This study was done to validate bone turnover markers using total skeletal uptake (TSU) of 99m Tc-MDP. 22 postmenopausal women (52–80 years) volunteered to participate. Scintigraphy was performed by injecting 520 MBq of 99m Tc-MDP and taking whole body images after 3 minutes, and 5 hours. TSU was calculated from these two images by taking into account the urinary loss and soft tissue uptake. Bone turnover markers used were bone specific alkaline phosphatase (S-Bone ALP), three different assays for serum osteocalcin (OC), tartrate resistant acid phosphatase 5b (S-TRACP5b), serum C-terminal cross-linked telopeptides of type I collagen (S-CTX-I) and three assays for urinary osteocalcin (U-OC). The median TSU of 99m Tc-MDP was 23% of the administered activity. All bone turnover markers were significantly correlated with TSU with r-values from 0.52 (p = 0.013) to 0.90 (p < 0.001). The two resorption markers had numerically higher correlations (S-TRACP5b r = 0.90, S-CTX-I r = 0.80) than the formation markers (S-Total OC r = 0.72, S-Bone ALP r = 0.66), but the difference was not statistically significant. TSU did not correlate with age, weight, body mass index or bone mineral density. In conclusion, bone turnover markers are strongly correlated with total skeletal uptake of 99m Tc-MDP. There were no significant differences in correlations for bone formation and resorption markers. This should be due to the coupling between formation and resorption

  18. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2003-01-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether 99m Tc-HMPAO or 99m Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8±6.6 years) were assigned to 99m Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6±6.7 years) to 99m Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq 99m Tc-HMPAO or 99m Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether 99m Tc-HMPAO and 99m Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  19. Update of the BIPM.RI(II)-K1.Tc-99m comparison of activity measurements for the radionuclide {sup 99m}Tc to include new results for the LNE-LNHB and the NPL

    Energy Technology Data Exchange (ETDEWEB)

    Michotte, C.; Courte, S.; Ratel, G. [Bureau International des Poids et Mesures (BIPM), 92 - Sevres (France); Moune, M. [LNE-LNHB, Laboratoire national de metrologie et d' essais-Laboratoire National Henri Becquerel, Gif sur Yvette (France); Johansson, L.; Keightley, J. [National Physical Laboratory (NPL), Middlesex (United Kingdom)

    2010-12-15

    In 2007 and 2008 respectively, the Laboratoire national de metrologie et d'essais -Laboratoire national Henri Becquerel (LNE-LNHB), France and the National Physical Laboratory (NPL), UK, submitted ampoules with between 10 MBq and 130 MBq activity of {sup 99m}Tc to the International Reference System (SIR), to update their results in the BIPM.RI(II)-K1.Tc-99m comparison. Together with the four other national metrology institutes (NMI) that are participants, thirteen samples have been submitted since 1983. The key comparison reference value (KCRV) has been recalculated to include the latest primary results of the PTB and the LNE-LNB as this makes the evaluation more robust. The degrees of equivalence between each equivalent activity measured in the SIR are given in the form of a matrix for all six NMIs. A graphical presentation is also given. (authors)

  20. Model-based comparison of maternal and foetal organ doses from 99mTc pertechnetate, DMSA, DTPA, HDP, MAA and MAG3 diagnostic intakes during pregnancy

    International Nuclear Information System (INIS)

    Saunders, Margaret; Palmer, Maria; Preece, Alan; Millard, Roger

    2002-01-01

    Organ residence times were calculated for diagnostic intakes of 99m Tc pertechnetate, 2,3-dimercaptosuccinic acid (DMSA), diethylene triamine penta-acetic acid (DTPA), hydroxymethylene diphosphonate (HDP), macroaggregated albumin (MAA) and mercapto-acetyltriglycine (MAG 3 ) during the 1st and 3rd stages of pregnancy and used with the MIRDOSE3 pregnant female phantoms for generation of dose estimates. At stage 3 individual foetal organ doses were estimated via a surrogate phantom based on that for the new-born but with mean dose/cumulated activity (S) values scaled for compatibility with foetal whole body S. Stage 1 or 3 whole foetus doses ranged from 5.2 to 0.77 μGy MBq -1 respectively, analogous to current ICRP estimates for these agents using similar in vivo biodistribution model databases. Most stage 3 maternal and foetal organ doses were similar within a factor of 3, being higher in the foetus than the mother with pertechnetate, DTPA and MAG 3 , and lower with DMSA, HDP and MAA. Doses were more uniformly distributed among foetal organs than in the mother. Placental transfer was greatest with pertechnetate, where dose to the stage 3 foetal thyroid was 60-140 μGy MBq -1 . With each agent there was more placental transfer in stage 3 than in stage 1, but doses to stage 1 whole foetus were always higher, with the contribution from the mother dominant. For DMSA, HDP and MAG 3 the maternal contribution to total foetal body dose exceeded 93% for both stages. (orig.)

  1. Development of Tc-99m labeled myocardial imaging agent

    International Nuclear Information System (INIS)

    Jeong, J. M.; Jang, Y. S.; Kim, Y. J.; Lee, Y. S.; Kim, H. W.; Ray, G.; Lee, M. S.

    2006-02-01

    Lipophilic cations have been widely used for myocardial SPECT. We synthesized novel +1 charged lipophilic Tc-99m-labeled N,N'-disubstituted N2S2 derivatives and investigated their biodistribution. The N,N'-dimethyl-, N,N'-diethyl-, N,N'-bis(methoxyethyl)-, and N,N'-bis(ethoxyethyl)N2S2 derivatives were synthesized by alkylating disulfide form of N2S2 with corresponding alkyl halides and subsequently reduced with LAH in THF. To label with Tc-99m, 50% gluconic acid (0.1 ml), SnCl2·2H2O (10 μg), Tc-99m-pertechnetate (370 MBq/2.5 ml) and 0.5 M Na2CO3 (0.3 ml) were added to the compounds. These mixtures were reacted in boiling water bath for 30∼60 min. Radiochemical purities were checked by Whatman No.1 chromatography (normal saline, Rf 0.3∼0.4). Biodistribution of each compound was investigated after injecting 74 kBq (0.1 ml) of each Tc-99m-labeled compound to ICR-mice through the tail vein. Chemical structures of synthesized compounds were confirmed by GC-MSD and 1H-NMR spectroscopy. All of the Tc-99m-labeled compound showed labeling efficiencies of higher than 93%. In biodistribution study, the myocardial uptake of Tc-99m-N,N'-dimethylN2S2, Tc-99m-N,N'-diethylN2S2, Tc-99m-N,N'-bis(methoxyethyl)N2S2 and Tc-99m-N,N'-bis(ethoxyethyl)N2S2 were 5.38 ±0.96, 2.98 ±0.16, 4.27 ±0.47, 7.24 ±1.01% ID/g at 10 min and 5.34 ±1.57, 2.05 ±0.40, 1.02 ±0.16, 1.69 ±0.04% ID/g at 2 hr, respectively. We successfully synthesized Tc-99m-labeled N,N-disubstituted N2S2 derivatives that are novel lipophilic +1 charged compounds. We thought our results prove the feasibility of these compounds to use for myocardial SPECT agent

  2. Sequential Tc[sup 99m] mercaptoacetyl-triglycine (MAB3) renography as an evaluator of early renal transplant function

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, E.; Greene, A.; Brennan, P.; Donohue, J.; Carmody, M.; Keeling, F. (Department of Radiology and Nephrology, Beaumont Hospital, Dublin, Ireland (United Kingdom))

    1993-01-01

    A prospective study was carried out to evaluate the role of sequential Tc[sup 99m] MAG3 renography in assessing transplant function in the early post-operative period. Twenty patients were included in the study. Studies were performed on all patients at intervals of 48-72 hours until discharge. There were 11 clinically diagnosed episodes of rejection, 9 of which were correctly diagnosed using MAG3 renography. Six episodes of rejection were diagnosed prior to the onset of clinical symptoms. Two patients with graft infarction were correctly diagnosed. Six patients had evidence of transient renographic abnormalities in the immediate post-operative phase which were not associated with clinical symptoms, all of these resolved spontaneously on subsequent examinations and were presumed to be related to resolving acute tubular necrosis (ATN). The perfusion index was of no discriminatory value in this study. Sequential Tc[sup 99m] MAG3 renography is highly sensitive but entirely nonspecific in the evaluation of pathology in the transplant kidney. Rejection in an uncomplicated transplant can be readily detected in many cases well in advance of clinical manifestations. This study demonstrates that Tc[sup 99m] MAG3 renography is certainly equal to Tc[sup 99m] DTPA renography or Iodine 131 renography in assessing early transplant function. However, TC[sup 99m] MAG3 exposes the patient to considerably less radiation and the images are of superior quality. (au) (15 refs.).

  3. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  4. Separation of sup(99m)Tc from 99MoO3

    International Nuclear Information System (INIS)

    Tomicic, M.

    1977-07-01

    At the present time sup(99m)Tc is widely used in nuclear medicine and its uses are increasing. It can be produced by various methods, and of those most frequently used today two have special features making them particularly applicable to the large-scale production of instant sup(99m)Tc - these are solvent extraction with methyl-ethyl-ketone and the sublimation methods. This report presents a bibliographic review of these methods, their main perfomance parameters, and experience obtained from the development and operation of a sublimation generator. Separation of sup(99m)Tc from irradiated MoO 3 was carried out with high yields (75-95%) after multiple repetition of the separation process with molybdenum trioxide heated for half an hour at a maximum temperature of 850-890 deg C in an air flow. The activity ratio of molybdenum in the separated sup(99m)Tc was of the order of 4 x 10 -5 . (author)

  5. The method of activity determination of Tc-99m in ionization chamber

    International Nuclear Information System (INIS)

    Broda, R.

    1980-01-01

    The paper presents a method of finding the efficiency of sup(99m)Tc activity measurements in the ionization chamber, basing on 99 Mo activity measurements and the activity ratio of sup(99m)Tc to 99 Mo in 99 Mo + sup(99m)Tc solution. The activity of 99 Mo has been determined in 4πβ-γ coincidence system with liquid scintillator in β channel by means of the absolute method of two-stage coincidence. The activity ratio of sup(99m)Tc to 99 Mo has been determined by means of spectrometric method. The 99 Mo and sup(99m)Tc activities have been measured in 99 Mo + sup(99m)Tc generators, and the activity of sup(99m)Tc solution after elution has been measured. It has been shown that sup(99m)Tc activity, determined by means of the chamber method on the basis of the efficiency found, corresponds to the activity determined by means of spectrometric method, and that sup(99m)Tc activity, measured in generator before elution, is equal to the sum of sup(99m)Tc activity eluted and the one remained in generator. (author)

  6. To the radiotoxicity of {sup 99m}Tc radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Ftacnikova, S [Inst. of Preventive and Clinical Medicine, 83301 Bratislava (Slovakia)

    1996-12-31

    In this paper the radiotoxicity and RBE values of Auger electrons for {sup 99m}Tc radiopharmaceuticals were discussed. Expression for the expected RBE for {sup 99m}Tc compounds is given. For the Auger electrons emitted in the decay of {sup 99m}Tc the RBE(Auger) = 10 and a value of 20 for the radiation weighing factor were recommended. (J.K.) 4 refs.

  7. Comparison of 99mTc-annexin A5 with 18F-FDG for the detection of atherosclerosis in ApoE-/- mice

    International Nuclear Information System (INIS)

    Zhao, Yan; Morita, Koichi; Tamaki, Nagara; Kuge, Yuji; Zhao, Songji; Inubushi, Masayuki; Strauss, H.W.; Blankenberg, Francis G.

    2007-01-01

    99m Tc-annexin A5, a marker of ongoing apoptosis, and 18 F-FDG, a marker of the increased metabolism of inflammatory cells, are supposed to be useful in the detection of metabolically active atheroma. This study reports a comparison of the intralesional distribution of these tracers in relation to lesion development in ApoE-/- mice. Male ApoE-/- mice (n = 12-14/group) were maintained on a Western-type diet after the age of 5 weeks. At 25 weeks, 99m Tc-annexin A5 or 18 F-FDG was injected and the aortas were harvested for autoradiography (ARG) and Oil Red O staining. Regional radioactivity accumulation was compared in relation to the Oil Red O staining score (ranging from 0 to 3, a semiquantitative parameter for evaluating lesion development). Both 99m Tc-annexin A5 and 18 F-FDG showed preferential uptake into atherosclerotic lesions, with higher uptake levels for 18 F-FDG (mean, 56.07 %ID x kg/m 2 ) than for 99m Tc-annexin A5 (mean, 10.38 %ID x kg/m 2 ). The regional uptake levels of each tracer correlated with the Oil Red O staining score (r = 0.65, p 99m Tc-annexin A5; r = 0.56, p 18 F-FDG). The uptake ratios of advanced lesions (score >0.5) to early lesions (score 99m Tc-annexin A5 than for 18 F-FDG (f = 4.73, p = 0.03). Both 99m Tc-annexin A5 and 18 F-FDG accumulate in atherosclerotic lesions and correlate with the severity of each lesion. The higher absolute uptake levels of 18 F-FDG may be advantageous for lesion detection, whereas the preferential uptake of 99m Tc-annexin A5 in advanced lesions may be a useful indicator of late-stage lesions or vulnerable plaque transformation. (orig.)

  8. 99Mo-99mTc production development by (n, γ) reaction

    International Nuclear Information System (INIS)

    Izumo, Hironobu; Nishikata, Kaori; Kimura, Akihiro; Tanimoto, Masataka; Tsuchiya, Kunihiko; Ishihara, Masahiro; Kaminaga, Masanori

    2012-01-01

    The renewed JMTR will be started from the later half of JFY2012, and it is expected to various fields. Supply of 99 Mo in Japan depends only on imports from foreign countries. JAEA has a plan to produce 99 Mo, a parent nuclide of 99m Tc. JMTR will contribute to produce 99 Mo by (n, r) method as one of effective uses of the JMTR. In this paper, outline of the technical study items for production method of 99 Mo- 99m Tc in JMTR will be described. (author)

  9. Complexes of technetium-99m with tetrapeptides, a new class of 99mTc-labelled agents

    International Nuclear Information System (INIS)

    Vanbilloen, Hubert P.; Bormans, Guy M.; Roo, Michel J. de; Verbruggen, Alfons M.

    1995-01-01

    Tetrapeptides are a class of N4-tetraligands that can efficiently bind 99m Tc. In fact, tetrapeptides can be considered as derivatives of mercaptoacetyltriglycine (MAG3) in which the mercaptoacetyl moiety is replaced by a more stable and easier to handle aminoacyl group. Direct labelling of tetrapeptides with 99m Tc in alkaline medium (pH ≥ 11) in the presence of stannous ions gave a high yield (>95%) of one or two (probably isomeric) radiochemical species. Exchange labelling at different pH values in the presence of stannous tartrate resulted in lower yields of the same 99m Tc-labelled products as those formed during direct labelling. In addition, other radiochemical species were formed of which one was characterized as an oxotechnetium-complex with the cyclisized tetrapeptide. Tetrapeptides with a chiral centre in the first amino acid yield upon labelling with 99m Tc two radiochemical species, probably the two diastereomers with an oxotechnetium core respectively syn and anti with respect to the substituent on the amino acid. Only one diastereomer was observed when the chiral carbon atom is located in the second or third amino acid. Electrophoresis indicated that these new 99m Tc-labelled complexes are neutral in acidic medium and negatively charged in neutral and alkaline conditions. This correlates with a complex in which an oxotechnetium(V) group is bound to the ligand through three deprotonated nitrogen atoms of the amide functions and the free electron pair of the amine nitrogen atom. Biodistribution in mice showed for all studied 99m Tc-labelled tetrapeptides a rapid clearance from the blood mainly by the renal system. The presence of a methyl substituent in the tetrapeptide increased the urinary excretion. 99m Tc-labelledl -glycylalanylglycylglycine showed in mice a urinary excretion comparable to that of 99m Tc-MAG3. Further rise of lipophilicity by introduction of a dimethyl, isopropyl or isobutyryl group leads to increased hepatobiliary handling. It

  10. Preclinical pharmacological study of 99mTcN(NOET)2 and comparison with 201Tl in redistribution of ischemia myocardium

    International Nuclear Information System (INIS)

    Wang, J.C.; Zhang, J.B.; Wang, Q.; Mi, H.Z.; Wang, X.B.

    2002-01-01

    Aim: To study the biological properties of the myocardial imaging agent 99m TcN(NOET) 2 and compare with 201 Tl in redistribution of ischemia myocardium. Materials and Methods: To prepared the 99m TcN(NOET) 2 complex, the intermediate [ 99m TcN] 2+ and ligand NOET were synthesized. In the presence of reducer and the doner of N, the [ 99m Tc=N] 2+ could be synthesized at 100, then NOET was added, 99m TcN(NOET) 2 was formed at room temperature. 201 Tl was provided by the Department of Isotope, China Institute of Atomic Energy. Five dogs were from the Fu Wai experimental animal feeding center, two of them were made into ischemia myocardium models by ligating some coronary artery branches were demonstrated by X-ray coronary angiography, the extent of stenosis of those blood vessels was over 90%. Dynamic imaging of rest was performed respectively in three normal dogs after injecting a dose of 555MBq (15mCi) of 99m TcN(NOET) 2 complex up to two hours. The whole body imaging planar and tomography imaging was carried out respectively at fixed time intervals during two hours in order to obtain the time-activity curves of heart, lung and liver, in vivo biodistribution and quality analysis of myocardial images. Moreover, intravenous blood samples were collected at different times to gain the kinetics of blood clearance. Stress and redistribution imaging underwent in two dogs with ischemia myocardium. Dipyridamol was given intravenously at a dose of 0.6mg/Kg in 4 mins. Stress :9 9m TcN(NOET) 2 myocardial SPECT imaging was performed at 30, 70 and 110 min after injection of 99m TcN(NOET) 2 complex, stress 201 Tl myocardial SPECT imaging was carried out 10 min and redistribution imaging 4 hr after injection of 55.5MBq (1.5mCi) 201 Tl chloride. The tests of 99m TcN(NOET) 2 and 201 Tl were performed respectively in the same dog within 10 days, in order to obtain a comparison between two myocardial redistribution imaging. Results: Radiochemical purity of 99m TcN(NOET) 2 was 98.41%

  11. Genotoxic effect of radio marked lymphocytes using Tc-99m complexes; Efecto genotoxico del radiomarcado de linfocitos empleando complejos de Tc-99m

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza L, M.; Ferro F, G.; Mendiola C, M.T.; Morales R, P. [Instituto nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The genotoxic effect of radio marked lymphocytes was evaluated using {sup 99m}-Tc-HMPAO and {sup 99m}-Tc- gentisic acid complexes. With the results of this work it is pretended to contribute to the knowledge of genetic and structural damages that provokes the radiation in the marked lymphocytes. The d, 1-HMPAO was synthesized in laboratory with a yielding of 30 %. The radiochemical purity of the complexes was greater than 85%. Mouse lymphocytes obtained of sanguineous volumes 2 ml were used. The radio marked efficiency of cells was 19.6 {+-} 6.4% and 25.6 {+-} 5.8% for {sup 99m}Tc-HMPAO and {sup 99m} Tc gentisic acid respectively. The genotoxic effect was evaluated using the technique of Unicellular Electrophoresis in Micro gel (Comet assay). The results showed that both {sup 99m} Tc complexes produce genotoxicity due to their capacity to penetrate cells, therefore the Auger and M internal conversion electrons place all their energy obtaining doses of Gray order. (Author)

  12. Spent 99Mo/99mTc generator as an economical source of 99Mo

    International Nuclear Information System (INIS)

    El-Kolaly, M.T.

    1990-01-01

    An improved method for utilization and purification of 99 Mo from spent 90 Mo/ 99m Tc generators has been described. After washing the generator with saline to remove the generated 99m Tc, followed by 2 mL 5 M NaOH containing a few drops of H 2 O 2 , the 99 Mo was quantitatively eluted from the generator with 5 mL 5 M NaOH. The alkaline eluate containing 99 Mo was contaminated with partially dissolved alumina. In the present method, an anion-exchange resin Dowex 1 x 8 column was used for purification of 99 Mo from the contaminating alumina. The resultant 99 Mo was of high purity and contained 3+ /mL 99 Mo solution, as estimated by atomic absorption. (author)

  13. Somatostatin analogues labelled with 99mTc

    International Nuclear Information System (INIS)

    Obenaus, E.; Crudo, J.; Edreira, M.; Viaggi, M.; De Castiglia, S.G.

    2001-01-01

    The aim of the present work was to study the biological and radiochemical behaviour of two somatostatin analogues, the RC-160 and Tyr3Octreotide(TOC) peptides when labelling with 99m Tc by two methods: direct and indirect using S-benzoyl- mercaptoacetyl triglycine (MAG-3) and hydrazinonicotinamide (HYNIC) as chelating agents. RC-160 was labelled with 125I (30% labelling yield) in order to examine its receptor specificity and to study the biodistribution in normal animals. A total binding of 30% and a non specific binding lower than 10% was obtained. On the other hand, the RC-160 was labelled with 99m Tc by a direct method (70% labelling yield), using sodium ascorbate and dithionite in order to reduce the peptide and 99m Tc, respectively. The synthesis of RC-160 with S-benzoyl MAG-3 and TOC with HYNIC, for labelling with 99m Tc are also described. The conjugates were prepared on a small scale and labelled with the radionuclide using tricine as co-ligands for HYNIC conjugates. Chromatographic studies were performed using HPLC system and radiochemical purities higher than 75% and 95% were obtained respectively. Biodistributions studies in normal Wistar rats were performed and results were correlated with chromatographic and protein binding properties. Lower lipophilicity of the labelled conjugates resulted in a higher renal excretion. HYNIC-TOC complex showed promising results when labelling with 99m Tc using tricine as co-ligand although higher stability should be found for ternary co-ligands compared to tricine. (author)

  14. 99mTc-HMPAO SPECT in pediatric patients with neurological disorders

    International Nuclear Information System (INIS)

    Yamaoka, Mitsuko

    1994-01-01

    In 125 pediatric patients with suspected brain diseases, EEG, CT and MRI findings were compared with those obtained with single photon emission computed tomography (SPECT) of the brain using Tc-99m-d, 1-hexamethyl-propylene amine oxime ( 99m Tc-HMPAO), to determine the usefulness of SPECT as an adjunct to EEG, CT and MRI in this age group. The incidences of abnormal finding in the 125 patients were 53.6, 75.2, 60.6 and 51.4% using 99m Tc-HMPAO SPECT, EEG, CT and MRI respectively. In localization-related epilepsy and cerebrovascular diseases, the incidence of abnormality was higher with 99m Tc-HMPAO SPECT than with either CT or MRI. There was a tendency for mean age to be higher and mean IQ or DG lower in patients with more extensive abnormality in comparison to those who had normal or only focally abnormal SPECT findings. Nevertheless, some patients showed focal hypofusion in the frontal or occipital area without significant mental retardation. Epileptic foci detected by EEG corresponded to defects found using 99m Tc-HMPAO SPECT in 34.8% of the symptomatic localization-related epileptic patients. Pathological lesions detected by CT or MRI corresponded with SPECT findings in 48.1% of patients. Furthermore, the incidence of abnormal findings on SPECT was 30% in patients in whom CT or MRI was normal. Epileptic foci detected by EEG did not correspond well with the area of focal hyperfusion found on SPECT. Focal hyperfusion may sometimes occur even in the interictal period or postictal period in childhood seizure disorders. In conclusion, 99m Tc-HMPAO SPECT revealed abnormal findings at a moderate incidence in neuropediatric patients. Correlations with EEG, CT and MRI findings as well as assessment of clinical signs, including the investigation of epileptic foci, are essential for adequate interpretation of brain functions. (author)

  15. Development of 99mTc extraction techniques from 99Mo by (n,γ) reaction

    International Nuclear Information System (INIS)

    Kimura, Akihiro; Hori, Naohiko; Tsuchiya, Kunihiko; Ishihara, Masahiro; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Sato, Yuichi

    2010-11-01

    Investigation of production method of 99 Mo by (n, γ) reaction, where the processing is relatively simple and generating less amount of radioactive waste, is conducted in the Neutron Irradiation and Testing Reactor Center. The 99 Mo is adsorbed to highly efficient adsorbent PZC after neutron irradiation and 99m Tc is eluted. However, radioactivity concentration of the 99m Tc solution obtained from PZC column loaded with 99 Mo derived by (n, γ) method is lower than that obtained from alumina column with 99 Mo by (n, f) method due to extremely low specific activity of (n, f) 99 Mo. Therefore, it is necessary to develop technique for increasing the amount of 99 Mo and the 99m Tc solution of high radioactivity concentration (minimum: 1Ci/ cm 3 ). In this study, the preliminary fabrication tests using high density MoO 3 pellets were carried out to increase the production of 99 Mo. The method of concentrating 99m Tc solution through solvent extraction with MEK was investigated and a device for this concentration process was also developed. In the preliminary tests of the MoO 3 pellets, the pellets having high density were successfully fabricated by the SPS method. Additionally, it was ascertained that the pellets can be dissolved with 6M-NaOH solution completely. The test for 99 Mo adsorption followed by 99m Tc elution using PZC was carried out. As the result, amount of Mo adsorbed to 1g-PZC was about 250mg, and 99m Tc yield was about 80%. In the concentration test using Re solution instead of 99m Tc solution, it was ascertained that the concentration efficiency is higher than 80% of the theoretical value. A concentration device for 99m Tc solution could be realized based on the method employed in the present experiments. The outcomes of development of 99m Tc extraction techniques from 99 Mo by (n,γ) reaction was reviewed in this paper, and the contents were presented in the 3rd International Symposium on Material Test Reactors. (author)

  16. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    Science.gov (United States)

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. Synthesis and characterization of zirconium molybdates of 99 Mo/99m Tc generators

    International Nuclear Information System (INIS)

    Contreras R, A.; Monroy G, F.; Diaz A, L.V.

    2002-01-01

    The zirconium molybdates are gels which are used as cation exchangers in the production of 99 Mo/ 99m Tc generators. The synthesis method and the characterization of these gels by thermogravimetry, infrared spectroscopy and X-ray diffraction is presented with the purpose of finding which the factors are that influence in the efficiency of the 99m Tc production. The results show that the quantity of molecular water contained in gel, is possibly the cause of variations of the efficiencies of the 99 Mo/ 99m Tc generator. (Author)

  18. Experimental and clinical studies on hepatobiliary scintigraphy and function test with sup(99m)Tc-E-HIDA

    International Nuclear Information System (INIS)

    Narabayashi, Isamu; Otsuka, Nobuaki; Terashima, Hideaki; Yokobayashi, Tsuneo; Kaji, Tatsumi

    1980-01-01

    In experimental and clinical studies, the usefulness of sup(99m)Tc-E-HIDA has been evaluated for dynamic imaging and function test. Biological distribution of sup(99m)Tc-E-HIDA in rabbits at 1 hour after the intravenous administration indicated that activity was 62% of the injected dose in the gallbladder and intestine, 2% in the liver, and 9% in the kidneys and urine. Hepatic uptake and excretion of sup(99m)Tc-E-HIDA were discussed in comparison with those of sup(99m)Tc-p-butyl-IDA, sup(99m)Tc-HIDA, sup(99m)Tc-PI and 123 I-RB. Radiochemical purity was ascertained by thin layer chromatography in saline. Labelling was nearly 100%, namely no unreacted pertechnetate was detected. In clinical study, the imaging of liver, bile ducts, gallbladder and intestine was satisfactory with sup(99m)Tc-E-HIDA. There was no or faint renal visualization in cases with hepatic uptake on the hepatogram. Quantitative analysis of blood retention, blood clearance and hepatogram with sup(99m)Tc-E-HIDA reflected excretory liver function in various hepatobiliary disorders. We concluded that sup(99m)Tc-E-HIDA has a lower urinary excretion and seems more effective than the other sup(99m)Tc-labels, such as sup(99m)Tc-HIDA and sup(99m)Tc-PI, at higher bilirubin levels. However, when the level of the bilirubin in blood rises above 7.4 mg/dl, no hepatic uptake of sup(99m)Tc-E-HIDA was obtained with greater renal excretion. (author)

  19. Evaluation of breast MIBI-Tc 99 m scintigraphy for the detection of breast cancer

    International Nuclear Information System (INIS)

    Loriaux, C.; Baeyens, L.; Paternot, J.; Martin, P.; Verhas, M.

    1997-01-01

    Full text. The aim of the work was to appreciate the contribution of MIBI-Tc 99 m scintigraphy for the detection of breast cancer and to situate this procedure in comparison with mammography 5 (X-ray M) and echography (E C). 21 patients presenting suspected lesion on clinical evaluation/or mammography were referred to the department for breast MIBI-Tc 99 m scintigraphy. 10 min after IV injection of MIBI-Tc 99 m 3 planar scan were realized with a present time of 10 min. The whole investigation including X-ray and surgical procedures were performed within 15 days. The pathologic findings were: 21 malignant lesion (18 canal cancers, 3 lobular cancers), 4 benign lesions (1 fibroadenoma, 2 granuloma, 1 fibrocystic disease). Lesions were bilateral in 3 cases and there was 1 bifocal lesion. 17 tumours were palpable and 8 not palpable, 10 lesion were 2,5 cm (24%). The overall sensitivity and specificity for MIBI-Tc 99 m were 67% and 75% respectively. For the group of palpable tumours, sensitivity of MIBI-Tc 99 m was 86%. In three cases, the X-ray M was difficult to interpret, the MIBI-Tc 99 m was true positive. In 3 false positive X-ray M procedures, the scintigraphy was true negative but, whatever the size of the tumor the best sensitivity was obtained with X-ray M (71%) and E C (70%) while for MIBI Tc-99 m, sensitivity was less (67%). MIBI-Tc 99 m appears to be a complementary tool in cases of difficulty of interpretation of mammography particularly in case of recurrence of the disease

  20. Homogeneous SLOWPOKE reactors for Mo-99/Tc-99m production in North America

    Energy Technology Data Exchange (ETDEWEB)

    Hilborn, J.W., E-mail: hilbovanw@sympatico.ca [Deep River, Ontario (Canada); Bonin, H.W. [Royal Military College of Canada, Kingston, Ontario (Canada)

    2014-07-01

    The 15 month shutdown of NRU in 2009 - 2010 caused an overall isotope shortage of approximately 30%; and in North America, the annual Tc-99m demand decreased from an estimated 20 million unit doses to about 15 million unit doses. Mo-99/Tc-99m is produced from HEU targets, irradiated in NRU for 11 days, and after chemical removal of uranium it is shipped to Nordion in Kanata, Ontario. Nordion further purifies the material and sends it to Lantheus Medical Imaging in the USA for manufacture of Mo-99 generators, which are then distributed to hundreds of hospital radiopharmacies throughout North America. One other American company, Covidien, manufactures and distributes Mo-99 generators like Lantheus, but they import bulk Mo-99 from Europe or South Africa. At the hospitals, Tc-99m is chemically extracted daily from the Mo-99 generators and loaded into syringes for immediate clinical use. Fortuitously, the 66 hour half-life of Mo-99 allows the replenishment of Tc-99m in the generator over a growth period of about 20 hours; and a generator can be 'milked' daily for up to two weeks. A more efficient model is the direct production and distribution of Tc-99m unit doses to regional hospitals from 10 'industrial' radiopharmacies located at existing licensed reactor sites in North America. A 20 kW homogeneous SLOWPOKE reactor at each site would deliver 15 litres of irradiated uranyl sulphate fuel solution daily to industrial-scale hot cells for extraction of Mo-99, which would be incorporated in large Mo-99/Tc-99m generators for extraction of Tc-99m five days a week; and the Low Enriched Uranium (LEU) would be recycled. Each automated hot-cell facility would be designed to load up to 7,000 Tc-99m syringes daily, for courier delivery to all of the Nuclear Medicine hospitals within a 3 hour average range by road transport. Typically, the delivered doses would be in the range 10 to 30 mCi. Assuming an average unit dose of 25 mCi at the hospital and 5 x 52

  1. Experimental study of per-rectal portal scintigraphy using 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Tamaki, Satoshi; Shinotsuka, Akira; Takenaka, Hiroki

    1991-01-01

    We discovered that 99m Tc-diethyl iminodiacetic acid ( 99m Tc-EHIDA) commonly used for hepatobiliary scintigraphy could also be administered per-rectally, with adequate absorption and optimal visualization of the portal system. To evaluate its usefulness, we experimented on rabbits using the method. Portal scintigraphy with rectal administration of 99m Tc-EHIDA, 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP) and 99m Tc-red blood cell ( 99m Tc-RBC) were performed in normal rabbits and in extrahepatic portal shunt model rabbits. Images of the liver and thorax were obtained and shunt indices were calculated from the count values of liver and lung or heart. Then the shunt indices were compared with shunt rate derived from direct injection of 99m Tc-macroaglutinated albumin ( 99m Tc-MAA) into inferior mesenteric vein. Correlation between shunt rate of 99m Tc-MAA and shunt indices of 99m Tc-RBC, 123 I-IMP and 99m Tc-EHIDA were 0.64, 0.75 and 0.78, respectively, with 99m Tc-EHIDA having the most favorable results. We concluded that 99m Tc-EHIDA per-rectal portal scintigraphy is a noninvasive, quantitative, inexpensive and simple method for evaluation of portal circulation system. Also, we think that this method would be applicable to human usage from our experience with normal volunteers. (author)

  2. Synthesis and characterization of zirconium molybdates of {sup 99} Mo/{sup 99m} Tc generators; Sintesis y caracterizacion de molibdatos de zirconio de generadores {sup 99} Mo/{sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Contreras R, A.; Monroy G, F.; Diaz A, L.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The zirconium molybdates are gels which are used as cation exchangers in the production of {sup 99} Mo/{sup 99m} Tc generators. The synthesis method and the characterization of these gels by thermogravimetry, infrared spectroscopy and X-ray diffraction is presented with the purpose of finding which the factors are that influence in the efficiency of the {sup 99m} Tc production. The results show that the quantity of molecular water contained in gel, is possibly the cause of variations of the efficiencies of the {sup 99} Mo/{sup 99m} Tc generator. (Author)

  3. Hepatobiliary scanning using /sup 99m/Tc--pyridoxylideneglutamate

    International Nuclear Information System (INIS)

    Matolo, N.M.; Stadalnik, R.C.; Wolfman, E.F. Jr.

    1977-01-01

    Technetium 99m-pyridoxylideneglutamate (99mTc-PG) administered intravenously is excreted by hepatocytes into the bile canaliculi and enters the gallbladder through the cystic duct and consequently, can be used for scanning the hepatobiliary ductal system. A total of 166 patients representing 27 normal subjects, 84 patients referred for investigation for pain in the upper right quadrant of the abdomen and 55 jaundiced patients were evaluated with 99mTc-PG. In normal human volunteers, the agent reached the liver in five minutes, and the common bile duct, gallbladder, and duodenum within 15 minutes. Satisfactory images of the hepatobiliary tract were obtained using small dosages of 99mTc-PG. The gallbladder was not visualized when the cystic duct was occluded. In the presence of acute cholecystitis, cystic duct obstruction, or in chronic cholecystitis where other roentgenographic studies showed a nonfunctioning gallbladder, there was no concentration of 99mTc-PG in the gallbladder. In partial common bile duct obstruction, distended common bile duct was visualized along with delay in transit of radioactivity into the duodenum. Complete common bile duct obstruction was associated with no radioactivity in either the biliary or the gastrointestinal tracts up to 24 hours after injection. Hepatocellular disease was characterized by delayed liver clearance and delayed visualization of biliary and gastrointestinal tracts. 99mTc-PG scanning proved capable of differentiating betweenhepatocellular disease and extrahepatic biliary tract obstruction

  4. Biological evaluation of 99m Tc-N-(3-bromo-trimethyl-acetanilide)-iminodiacetic acid (99mTc mebrofenin) as hepatobiliary radiopharmaceutical

    International Nuclear Information System (INIS)

    Hamada, E.S.

    1994-01-01

    Technetium-99 m-N-(3-bromo-2,4,6-trimethyl acetanilide) iminodiacetic acid ( 99m Tc-Mebrofenin) has been described as having optimal properties as hepatobiliary radiopharmaceutical. This paper describes the synthesis, radiopharmaceutical preparation and biological distribution of new labeled compound. The biodistribution study of 99m Tc-Mebrofenin- was carried out in normal mice. The specificity for hepatobiliary excretion blood clearance and cumulative biliary excretion were evaluated in normal and cirrhotic rats. (author). 5 refs, 3 figs, 3 tabs

  5. Novel Tc-99m radiotracers for brain imaging

    Directory of Open Access Journals (Sweden)

    Alessandra Boschi

    2007-09-01

    Full Text Available A novel class of Tc-99m complexes able to cross the blood brain barrier has been investigated and described here. These compounds are formed by reacting the bis-substituted nitrido precusors [99mTc(N(PS2] (PS = phosphino-thiol ligand with triethylborane (BEt3 under strictly anhydrous conditions and using non-aqueous solvents. The molecular structure of these tracers was not fully established, but preliminary experimental evidence suggests that they result from the interaction of the Lewis base [99mTc(N(PS2] with the Lewis acid BEt3, which leads to the formation of the novel -B-Nº Tc- adduct. After purification and recovery in a physiological solution, the new borane-nitrido Tc-99m derivatives were injected in rats for evaluating their in vivo biological behavior. Results showed a significant accumulation in brain tissue, thus indicating that these complexes are capable of penetrating the intact blood brain barrier. Uptake in the central nervous system was confirmed by imaging the distribution of activity on the integrated living animal using a YAP(SSPECT small animal scanner.Uma nova classe de complexos de Tc-99m capazes de atravessar a barreira hemato-encefálica foi investigada e descrita neste trabalho. Estes compostos são formados reagindo os precursores bissubstituídos do nitrido [99mTc(N(PS2] (PS = phosphino-tiol ligante com trietillborano (BEt3 sob restritas condições anidras e usando solventes não aquosos. A estrutura molecular desses traçadores não foi totalmente estabelecida, mas evidências experimentais preliminares sugerem que eles resultam da interação da base de Lewis [99mTc(N(PS2] com o ácido de Lewis BEt3, levando a formação do novo aducto -B-Nº Tc-. Após purificação e recuperação em uma solução fisiológica, os novos derivados borano-nitrido-Tc-99m foram injetados em ratos para avaliação de seu comportamento biológico in vivo. Os resultados mostraram uma acumulação significativa no tecido cerebral

  6. Studies on the porphine labeled with 99mTc-pertechnetate

    International Nuclear Information System (INIS)

    Ai-Yih Wang; Jiunn-Liang Lin; Wen-Chieh Lin

    2010-01-01

    The aim of this research is to use acetylacetonate as a 99m Tc chelating agent label with porphyrin and evaluate its radiochemical and biological characteristics. Stannous chloride was used as a reductant to determine the chemical and biological characterization of 99m Tc-complexes from labeling porphine (4',4'',4'''-(2lH,23H-Porphine-5,10,15,20-terayl)tetrakis-(benzoic acid), TPPB) with 99m Tc-pertechnetate. Instant thin layer chromatography (ITLC), size exclusion chromatography (SEC), paper electrophoresis, and UV/Vis spectrophotometry were used to evaluate chemical characterization. Finally, biodistribution and liver function tests were applied to evaluate biological characteristics. The results of this study show that the labeling efficiency of 99m Tc(acac)-TPPB was nearly 100% when using acetylacetone (acac) as a conjugator. Three major 99m Tc(acac)-TPPB complexes were separated by SEC, and all of them were hydrophilic. The UV-Vis spectra of 99m Tc(acac)-TPPB complexes closely resembled those of the TPPB, but the wave lengths of their peaks changed 430, 521, 556, 591 and 647 nm after complexation. The biodistribution study selected the liver as the target organ. The 99m Tc(acac)-TPPB complex may cause short-term liver injury. However, this injury can be repaired, and the reagent is quickly metabolized. Hence, the toxicity of the 99m Tc(acac)-TPPB complex is within an acceptable range, and making it a promising liver imaging agent. (author)

  7. Technetium-99m diethylenetriaminepentaacetic acid radioaerosol scintigraphy in organophosphate induced pulmonary toxicity: experimental study.

    Science.gov (United States)

    Yavuz, Yucel; Kaya, Eser; Yurumez, Yusuf; Sahin, Onder; Bas, Orhan; Fidan, Huseyin; Sezer, Murat

    2008-09-01

    The aim of this experimental study was to investigate pathological signs of lung damages caused by acute organophosphate (OP) poisoning by using Tc-99m DTPA radioaerosol scintigraphy and histopathological investigation. Fourteen rabbits were divided into two equal groups (n = 7). Group 1 (control group) received normal saline (same volume of fenthion, 2 ml/kg) via orogastric tube. Group 2 (OP toxicity group) received 150 mg/kg of fenthion (diluted fenthion, 2 ml/kg) via orogastric tube. Six hours later, Tc-99m-DTPA aerosol inhalation lung scintigraphy was performed in both groups. Then all rabbits were anesthetized with ketamine hydrochloride (35 mg/kg, i.p.) and xysilazine (5 mg/kg, i.p.), and sacrificed by intracardiac blood discharge. The lungs were then removed. There was a significant difference in T1/2 values of Tc-99m DTPA clearance between control group and OP toxicity group (p = 0.04). Intraparenchymal vascular congestion and thrombosis, intraparenchymal hemorrhage, respiratory epithelial proliferation, number of macrophages in the alveolar, and bronchial lumen, alveolar destruction, emphysematous changes, and bronchoalveolar hemorrhage scores were significantly higher in the rabbits exposed to OP compared with the control group (p < 0.05). This study showed that OP toxicity caused a decrease in the alveolar clearance. Tc-99m DTPA radioaerosol inhalation lung scintigraphy was found to be a sensitive determination of acute lung damage in OP poisoning.

  8. The study of x-ray photo-electron spectroscopy of 99mTc-RBC

    International Nuclear Information System (INIS)

    Song Chunyi

    1994-01-01

    99m Tc-RBC are widely used as visualization agents for a blood pool. In this research 99m Tc-RBC was prepared by in vivo labeling. The chemical state and changes of 99m Tc atoms in 99m Tc-RBC was determined by x-ray photo-electron spectroscopy (XPS). The stability of 99m Tc-RBC is best shown by the determination of XPS at one hour or at two hours after labeling. There are two ways of coordination of bonding of RBC and 99m Tc: One is the coordination of 99m Tc with the oxygen atom which carries a negative charge of the carboxyl radical on the polypeptide bond, the other is the coordination of 99m Tc with a sulfur atom which caries the negative charge of cysteine. From the E b value of 99m Tc-RBC 99m Tc 3d5/2, it can be inferred that 99m Tc of 99m Tc-RBC is less than a trivalent. At the same time, the results of the determination by XPS with the compounds containing 99 TcO 4 - , 99 Tc(V), 99 Tc(IV) and 99 Tc(III) show that the chemical shift is lowered as the reduction state is lowered. Experimental results coincide with theoretical inferences

  9. Clinical estimation of sup(99m)Tc-labeled compounds produced by electrolysis

    International Nuclear Information System (INIS)

    Watanabe, Katsuji; Kawahira, Kenjiro; Kamoi, Itsuma; Morita, Kazunori

    1974-01-01

    Scintigrams were made using sup(99m)Tc-Sn-colloid, sup(99m)Tc-pyrophosphate, sup(99m)Tc-EDTA and sup(99m)Tc-albumin prepared by electrolysis, and a clinical evaluation was attempted. No side effects were recognized in 228 cases, therefore the object of this study could be attained. Future study was thought to be necessary because the pictures were somewhat indistinct. However, each sup(99m)Tc-labeled compound could be prepared very easily and was extremely convenient for daily use. sup(99m)Tc- is a nuclide which has many advantages for use with scintigrams. More useful sup(99m)Tc-labeled compounds will be explored in the future and is expected that electrolysis has many possibilities for use in the preparation of sup(99m)Tc-labeled compounds. (Tsunoda, M.)

  10. Scintigraphic visualization of extrahepatic portal circulation in patients with portal hypertension using /sup 99m/Tc-tin-colloid and /sup 99m/Tc-HIDA

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hussoni, M H; Jasim, M N; Shubbar, A H

    1985-01-01

    Rapid dynamic sequential scintigraphy of the abdomen with /sup 99m/Tc-tin-colloid and /sup 99m/Tc-HIDA has been used to evaluate two patients with portal hypertension. /sup 99m/Tc-tin-colloid was useful for visualization of diliated vessels in the abdomen. Radionuclide hepatobiliary imaging was useful in such cases in evaluation of the hepatobiliary system.

  11. Indications for pediatric 99mTc-dimercaptosuccinic-scintigraphy

    International Nuclear Information System (INIS)

    Meller, J.; Becker, W.; Zappel, H.

    2000-01-01

    This paper gives an overview about the diagnostic use of 99m Tc-Dimercaptosuccinic ( 99m Tc-DMSA)-scintigraphy in siblings and children and presents our own results with this tracer in pediatric nephro-urology. 99m Tc-DMSA offers a high renal accumulation and therefore is suited for the diagnosis of renal malformations. Furthermore, a calculation of the tubular renal split function and imaging of the renal cortex is possible due its high tubular retention. The tracer may be used with success in the non invasive diagnostic work up of both renoparenchymal and renovascular hypertension in childhood and especially in the diagnosis of segmental renal artery stenosis. Scintigraphy with 99m Tc-DMSA is a simple and highly effective method in the diagnosis of pyelonephritis and renal scarring. It offers important informations about the further prognosis of a child with urinary tract infection. In upper urinary tract infection 99m Tc-DMSA-scintigraphy may be more specific than available clinical tests. In the diagnosis of pyelonephritis and renal scarring scintigraphic imaging has been proven to be more sensitive than pyelography and ultrasound and its diagnostic power is at least equal compared with computed tomography. Therefore, imaging with 99m Tc-DMSA can be considered as the reference method in these questions. Regarding that reflux is seen in less than 40% of children with a pathologic DMSA-scan and that the prognosis of children with an urinary tract infection without a pathologic DMSA-scan is usually good, one could question the use of micturating cystourethrography in the diagnostic work up of children with symptomatic urinary tract infection and a normal DMSA-scan. (orig.) [de

  12. Hypoxia-induced redox alterations and their correlation with 99mTc-MIBI and 99mTc-HL-91 uptake in colon cancer cells

    International Nuclear Information System (INIS)

    Abrantes, Ana Margarida; Silva Serra, Maria Elisa; Goncalves, Ana Cristina; Rio, Joana; Oliveiros, Barbara; Laranjo, Mafalda; Rocha-Gonsalves, Antonio Manuel; Sarmento-Ribeiro, Ana Bela; Filomena Botelho, Maria

    2010-01-01

    Colorectal cancer is one of the most common malignancies in the Western world and is an example of a solid tumour in which hypoxia is a common feature and develops because of the inability of the vascular system to supply adequate amounts of oxygen to growing tumours. Hypoxia effects on tumour cell biology can be detected and characterized using different methods. The use of imaging with γ-emitting radionuclides to detect hypoxic tissue was first suggested by Chapman in 1979 [N Engl J Med 301 (1979) 1429-1432]. 99m Tc-4,9-diaza-3,3,10,10-tetramethyldodecan-2,11-dione dioxime, also known as 99m Tc-HL-91, has been among the most studied hypoxia markers. The objective of this study was to correlate the uptake of 99m Tc-HL-91 and 99m Tc-MIBI in colon cancer cells under normoxic and hypoxic conditions and to compare this information with some parameters such as oxidative stress and mitochondrial dysfunction of the cells analyzed by flow cytometry. Our results show that the in vitro 99m Tc-HL-91 uptake is higher in hypoxic conditions, which is confirmed by the decreased uptake of 99m Tc-MIBI. Flow cytometry results demonstrate that hypoxic conditions used are not enough to induce cellular death, but are responsible for the alterations in the intracellular redox environment, namely, increase of ROS production, proteic pimonidazol-derived adduct formation and alteration in the mitochondrial membrane permeability. Therefore, these results confirm that 99m Tc-HL-91 is a radiopharmaceutical with favourable characteristics for detecting hypoxia.

  13. Prediction of two-sample 99mTc-diethylene triamine pentaacetic acid plasma clearance from single-sample method

    International Nuclear Information System (INIS)

    Zuo Li; Ma Ying-Chun; Wang Mei; Zhang Chun-Li; Wang Rong-Fu; Wang Hai-Yan

    2005-01-01

    The objective of this study was to develop an equation to predict dual plasma sample method (DPSM) 99m Tc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) plasma clearance from single plasma sample method (SPSM), and to clarify the condition in which DPSM can be substituted by SPSM in measurement of glomerular filtration rate (GFR). Patients with chronic kidney disease (CKD) were selected. Watson modified Christensen and Groth equation was used to calculate 99m Tc-DTPA plasma clearance by SPSM (sGFR). The equation recommended by the Nephrourology Committee of the Society of Nuclear Medicine was used to calculate 99m Tc-DTPA plasma clearance by DPSM (tGFR) in each patient. The difference between sGFR and tGFR was expressed as percent of the average of these two methods, and tGFR was predicted from sGFR. Plasma creatinine was measured by the kinetic picrate method, and GFR estimated by abbreviated modification of diet in renal disease (MDRD) equation (aGFR) and Cockcroft-Gault equation (cGFR) were evaluated as criteria in selection of DPSM and SPSM. Three hundred and sixty-nine patients with CKD were selected (208 male and 161 female). The average age and body weight were 51.4±15.5 years and 67.2±12.5 kg, respectively. The causes of CKD were glomerular disease, renal arterial stenosis, chronic tubulointerstitial disease, and other causes or causes unknown. The average tGFR was 62.9±36.5 ml/min/1.73 m 2 , ranging from 1-180 ml/min/1.73 m 2 . sGFR was significantly correlated with tGFR (r=0.9194, p 2 ; in contrast, then tGFR was±30 ml/min/1.73 m 2 , the difference was constant (-1.1%, 95% confidence interval -18.3%, 16.1%), and tGFR could be predicted from sGFR using the equation: predicted tGFR (ml/min/1.73 m 2 )=7 4244+0.7318 x sGFR+0.0022 x sGFR 2 (n=299, r 2 =0.9428, p 2 , the diagnostic sensitivity of a cut off value of aGFR=45 ml/min/1.73 m 2 was 91.8%, and recommended as a criterion in the selection of DPSM and SPSM. When GFR ≥30 ml/min/1.73 m 2 , t

  14. The development of 99mTc-d, 1-HM-PAO

    International Nuclear Information System (INIS)

    Bai Lanqin; Huang Jinjie; Fan Li; Bai Suzhen; Li Guoli; Jing Hui; Xiao Lun

    1991-12-01

    The 99m Tc-d,1-HM-PAO is an ideal radiopharmaceutical for regional cerebral blood perfusion imaging. The improvement of synthesis and separation of diastereoisomers leads to obtain high purity (>99%) of d, 1-HM-PAO and meso-HM-PAO. During separation H NMR spectroscopy was used to monitor the relative composition of these two diastereoisomers that can ensure the purity of pligand of d,1-HM-PAO. The intravenous injection of 99m Tc-d,1-HM-PAO was formed by adding fresh 99m Tc washing liquor into a sterile. Pyrogen-free and freeze-dried vial. The radiochemical purity (RCP) of 99m Tc-d,1-HM-PAO was greater than 80%. From the experiments of 99m Tc-d,1-HM-PAO in mice, after two minutes of intravenously (I>V>) administration about 2.24% of injected dose (I.D.)appeared in the brain, and after 24 hours about 72% of radioactivity of injected dose still left in the brain. But for the 99m Tc-meso-HM-PAO after two minutes of i.v. administration, about 1.93% of I.D. appeared in the brain, and 24 hours later, 25% of radioactivity of I.D. was in the brain. This result shows that in the brain the radioactivity of 99m Tc-meso-HM-PAO declines faster than that of 99m Td-d,1-HM-PAO

  15. Evaluation of sup(99m)Tc-Sn-colloid on liver scintigram

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyuki, Y; Kanao, K; Honda, M; Ishihara, S [Sumitomo Hospital, Osaka (Japan)

    1975-04-01

    sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set were used for nuclear medical examination of the liver and their efficiency was discussed. Both sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set showed the same kinetics in vivo, and the sup(99m)Tc-Sn-colloid rapidly disappeared from the serum and concentrated to the liver and spleen. Comparing /sup 198/Au-colloid, sup(99m)Tc-Sn-colloid could be increased the administration dose, and provided easy examination within short time period, easy observation from multiple directions, and improvement of resolution by scinticamera. Imaging of the spleen with sup(99m)Tc-Sn-colloid was slightly superior to that with sup(99m)Tc-sulfur-colloid. sup(99m)Tc-Sn-colloid injectable solution which required no procedure of labeling was evaluated as the most safe and easy technique. Side effects were not recognized. As the results, already made preparation, such as sup(99m)Tc-Sn-colloid injectable solution, which provided easy preparation with less absorbed dose of the tissue and high resolution would be frequently required.

  16. Evaluation of sup(99m)Tc-Sn-colloid on liver scintigram

    International Nuclear Information System (INIS)

    Matsuyuki, Yoshihiko; Kanao, Keisuke; Honda, Minoru; Ishihara, Shizumori

    1975-01-01

    sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set were used for nuclear medical examination of the liver and their efficiency was discussed. Both sup(99m)Tc-Sn-colloid injectable solution and Sn-colloid preparation set showed the same kinetics in vivo, and the sup(99m)Tc-Sn-colloid rapidly disappeared from the serum and concentrated to the liver and spleen. Comparing 198 Au-colloid, sup(99m)Tc-Sn-colloid could be increased the administration dose, and provided easy examination within short time period, easy observation from multiple directions, and improvement of resolution by scinticamera. Imaging of the spleen with sup(99m)Tc-Sn-colloid was slightly superior to that with sup(99m)Tc-sulfur-colloid. sup(99m)Tc-Sn-colloid injectable solution which required no procedure of labeling was evaluated as the most safe and easy technique. Side effects were not recognized. As the results, already made preparation, such as sup(99m)Tc-Sn-colloid injectable solution, which provided easy preparation with less absorbed dose of the tissue and high resolution would be frequently required. (Mukohata, S.)

  17. Multicenter trial validation of a camera-based method to measure Tc-99m mercaptoacetyltriglycine, or Tc-99m MAG3, clearance.

    Science.gov (United States)

    Taylor, A; Manatunga, A; Morton, K; Reese, L; Prato, F S; Greenberg, E; Folks, R; Kemp, B J; Jones, M E; Corrigan, P E; Galt, J; Eshima, L

    1997-07-01

    To evaluate an improved camera-based method for calculating the clearance of technetium-99m mercaptoacetyltriglycine (MAG3) in a multicenter trial. Tc-99m MAG3 scintigraphy was performed in 49 patients at three sites in the United States and Canada. The percentage of the injected dose of Tc-99m MAG3 in the kidney at 1-2, 1.0-2.5, and 2-3 minutes after injection was correlated with the plasma-based Tc-99m MAG3 clearances. The data were combined with the results obtained in 20 additional patients in a previously published pilot study. Regression models correlating the plasma-based Tc-99m MAG3 clearance with the percentage uptake in the kidney for each time interval were developed; there was no statistically significant difference among sites in the regression equations. Correction for body surface area statistically significantly (P time interval. For the 1.0-2.5-minute interval, the body surface area-corrected correlation coefficient for the four combined sites was .87, and it improved to .93 when one outlier was omitted from the analysis. Similar results were obtained with the other time intervals. Independent processing by two observers showed no clinically important differences in the percentage dose in the kidney or in relative function. An improved camera-based method to calculate the clearance of Tc-99m MAG3 was validated in a multicenter trial.

  18. Labelling of metaiodobenzylguanidine (MIBG) with Technetium-99m radionuclide

    International Nuclear Information System (INIS)

    Maula Eka Sriyani; Dini Natanegara; Aang Hanafiah Ws

    2015-01-01

    Various neuroendocrine tumors and their metastases are able to localized and staged by Metaiodobenzylguanidine (MIBG). MIBG is a molecule that has a chemical structure similarities with noradrenaline in the adrenal. The research on 131 I-MIBG has been successfully conducted in the tumor imaging. This research of preparing 99m Tc-MIBG that will be used as a diagnostic agent for adrenal tumors was carried out. MIBG labeling activities with technetium-99m radionuclide were carried out through labeling of MIBG with technetium-99m and radiochemical purity analysis. The labeling of MIBG was carried out using both direct and indirect methods with diethylene triamine pentaacetic acid (DTPA) as a co-ligand. Determination of 99m Tc-MIBG labeling efficiency was performed using paper chromatography with Whatman 3MM/dried acetone and Whatman 31ET/acetonitrile 50%. The results of labeling efficiency using the indirect method with DTPA as a co-ligand was obtained 93.44 ± 1.93%, which the concentration of MIBG was 2 mg/0.5 mL H 2 O, concentration of co-ligand was 37,5 μg of SnCl 2 .2H 2 O and DTPA of 1,125 mg at pH 6.5 for 15 minutes incubation in the room temperature ( 25 °C). (author)

  19. Receptor imaging with a new Tc-99m labelled somatostatin analogue (Tc-99m EDDA-TRYCINE-HYNIC-TOC): first clinical results and comparison with In-111 Dotatoc during radioreceptor therapy with Y-90 Dotatoc

    International Nuclear Information System (INIS)

    Baum, R.P.; Schmuecking, M.; Fischer, S.; Przetak, C.; Niesen, A.; Maecke, H.R.

    2002-01-01

    Full text: To evaluate Tc-99m EDDA-TRYCINE-HYNIC-TOC (TET-H-TOC) in patients with somatostatin receptor (SSTR)-positive tumors (staging, pretherapeutic indication for radioreceptor therapy and restaging after therapy) in comparison with In-111 DOTATOC. The Tc-99m labelled somatostatin analogue was synthesized by an optimized procedure in our pharmaceutical lab using lyophilized kits (radiochemical purity by HPLC, TLC > 95 %, product stability in vitro 4 to 6 h). So far, 46 patients (53 examinations) were studied after injection of 580-890 MBq (median 673 MBq) TET-H-TOC. The histologically proven tumors were endocrine neoplasias, renal carcinomas, bronchial carcinoma, mesothelioma and malignant fibrous histiocytoma. The imaging protocol consisted of whole-body scans and planar images of the tumor region (15 min, 1 h, 2 h, 4 h, 8 h, 24 h p.i.) and additionally SPECT-images (1 h and 4 h p.i.). For semi-quantitative assessment, individual regions of interest (ROI) were drawn in order to generate time-activity curves and to calculate tumor-to-tissue/background ratios which were compared by visual grading (scale 0 to 3+). Furthermore, pharmacokinetic analyses were carried out (radioactivity kinetics in plasma and urine). In some selected patients, image fusion of the whole-body scans was performed with CT and/or MRT and/or PET using a HERMES computer. 7 out of 46 patients showed an intense tracer accumulation in the SSTR-positive tumors (visual 3+, tumor / background ratio >2,5). In these patients, radioreceptor therapy was carried out using Y-90 DOTATOC (simultaneous injection of 150 MBq In-111 DOTATOC). All pretherapeutic scans with the Tc-99m labelled ligand (4 h p.i.) showed a similar overall pattern of biodistribution and tumor uptake in comparison to the therapy scans with In-111 / Y-90 DOTATOC 24 h p.i. The Tc-99m EDDA-HYNIC-TOC scans (incl. SPECT) offered superior imaging properties with earlier tumor visualization (all lesions were detected 1 h p.i.) as compared

  20. Discrepant 99mTc-ECD images of CBF in patients with subacute cerebral infarction. A comparison of CBF, CMRO2 and 99mTc-HMPAO imaging

    International Nuclear Information System (INIS)

    Shishido, Fumio; Uemura, Kazuo; Inugami, Atsushi; Ogawa, Toshihide; Fujita, Hideaki; Shimosegawa, Eku; Nagata, Ken.

    1995-01-01

    Three patients with subacute ischemic cerebral infarction examined by SPECT with 99m Tc-ECD and PET within the same day showed signs of luxury perfusion in the subacute phase, which is between 9 to 20 days after the onset. A 99m Tc-HMPAO SPECT study was also performed within 2 days of the ECD-SPECT study. ECD-SPECT images of three patients displayed a focal decreased uptake in the infarcted lesions, while in infarcted foci, there was almost equivalent or increased CBF compared to normal and unaffected areas, decreased CMRO 2 , and high HMPAO uptake. The ECD-SPECT results were similar to those of CMRO 2 rather than CBF, though the HMPAO-SPECT image was similar to that of CBF. In one patient, HMPAO images revealed hyperfixation of the tracer. In the chronic phase and in the acute phase before 5 days after the onset, there were no discrepancies among the ECD-SPECT, CBF, HMPAO-SPECT, and CMRO 2 images. These observations indicated that 99m Tc-ECD is a good indicator of damaged brain tissues in subacute ischemic infarction. They also suggested that 99m Tc-ECD is a potential agent with which to evaluate cerebral tissue viability in some pathological states of cerebrovascular disease. The characteristics may be suitable for confirming the effects of thrombolytic therapy in acute ischemia, because these conditions often show signs of luxury perfusion when the therapy is successful. (author)

  1. Evaluation of the liver scintigraphy with sup(99m)Tc-Sn-colloid, 2

    International Nuclear Information System (INIS)

    Kimura, Kazufumi; Nishimura, Tsunehiko; Takeda, Hiroshi; Furukawa, Toshiyuki; Kajiya, Fumihiko.

    1975-01-01

    Clinical significance of the liver scintigraphy with sup(99m)Tc-Sn-colloid was evaluated in comparison with those with 198 Au-colloid. The liver scintigrams with sup(99m)Tc-Sn-colloid and 198 Au-colloid were done in 36 cases of various hepatic diseases and RI accumulation curves in the liver and the spleen, and the blood disapearance curves were also obtained. The conclusions were as follows. The liver scintigrams with sup(99m)Tc-Sn-colloid proved to be more sensitive in the detection of tumors, especially, in the lower margin, left lobe and superficial layers of the liver than those with 198 Au-colloid. In all cases, including normal and cirrhotic subjects, visualizations of the spleen were seen on the scintigrams with sup(99m)Tc-Sn-colloid. In diffuse hepatic diseases, comparing both radiopharmaceuticals, the splenic accumulations were studied qualitatively and quantitatively. As a result, the ratio (spleen/liver) was thought to be useful for the differentiation of diffuse hepatic diseases concerned with splenic function and/or size. It was also shown that sup(99m)Tc-Sn-colloid was useful as a spleen scanning agent. The Tl/2 in the liver accumulation curves with sup(99m)Tc-Sn-colloid were not as clearly differentiated in the various hepatic diseases as those with 198 Au-colloid where those indexes were useful in the evaluation of liver functions. (auth.)

  2. Labelling and quality control of 99mTc labelled somatostatin analogues

    International Nuclear Information System (INIS)

    Poramatikul, N.; Sangsuriyan, J.; Kongpeth, P.; Ngamprayad, T.; Laloknam, S.; Permtermsin, C.; Madsomboon, N.

    2001-01-01

    To standardize interlaboratory reproducibility, iodination of RC-160 with 125 I and direct labelling of RC-160 with 99m Tc, quality control and binding assay were performed. Two conjugated peptides, HYNIC-RC-160 and MAG-3-RC-160, were synthesized. The conjugated peptides were radiolabelled with 99m Tc via co-ligands; 99m Tc-MAG-3-RC-160 via glucoheptonate, 99m Tc-HYNIC-RC-160 via EDDA and tricine. Conditions for labelling were optimized. Analytical and purification methods for the labelled products were developed. Radiochemical purity test of 99m Tc labelled peptides was performed by HPLC with gradient elution of 0.1%TFA/water and acetonitrile, or by ITLC-SG in saline and in 50% acetonitrile. The contaminants in 99m Tc radiolabelled product were separated by elution from SEPPAK C-18 cartridge by 0.1% acetic acid and the pure product was eluted out of SEPPAK column by 50% acetonitrile with about 68% recovery. Stability of the purified 99m Tc-MAG3-RC-160 stored at -20 deg. C was more than 72 h. 99m Tc-MAG-3-RC-160 showed a high equilibrium dissociation constant with K D of 26 pmole/mg protein and B max of 7.9 mM. (author)

  3. Evaluation of breast MIBI-Tc 99 m scintigraphy for the detection of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Loriaux, C.; Baeyens, L.; Paternot, J.; Martin, P.; Verhas, M. [Hospital Universitaire Brugmann, Bruxelles (Belgium). Service de Medecine Nucleaire et Clinique de Senologie

    1997-12-31

    Full text. The aim of the work was to appreciate the contribution of MIBI-Tc 99 m scintigraphy for the detection of breast cancer and to situate this procedure in comparison with mammography 5 (X-ray M) and echography (E C). 21 patients presenting suspected lesion on clinical evaluation/or mammography were referred to the department for breast MIBI-Tc 99 m scintigraphy. 10 min after IV injection of MIBI-Tc 99 m 3 planar scan were realized with a present time of 10 min. The whole investigation including X-ray and surgical procedures were performed within 15 days. The pathologic findings were: 21 malignant lesion (18 canal cancers, 3 lobular cancers), 4 benign lesions (1 fibroadenoma, 2 granuloma, 1 fibrocystic disease). Lesions were bilateral in 3 cases and there was 1 bifocal lesion. 17 tumours were palpable and 8 not palpable, 10 lesion were <1 cm (40%), 9 were between 1,1 and 2,5 cm (36%) and 7 were >2,5 cm (24%). The overall sensitivity and specificity for MIBI-Tc 99 m were 67% and 75% respectively. For the group of palpable tumours, sensitivity of MIBI-Tc 99 m was 86%. In three cases, the X-ray M was difficult to interpret, the MIBI-Tc 99 m was true positive. In 3 false positive X-ray M procedures, the scintigraphy was true negative but, whatever the size of the tumor the best sensitivity was obtained with X-ray M (71%) and E C (70%) while for MIBI Tc-99 m, sensitivity was less (67%). MIBI-Tc 99 m appears to be a complementary tool in cases of difficulty of interpretation of mammography particularly in case of recurrence of the disease

  4. Balloon-based adjuvant radiotherapy in breast cancer: comparison between {sup 99m}Tc and HDR {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Tarcisio Passos Ribeiro de; Lima, Carla Flavia de; Cuperschmid, Ethel Mizrahy, E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2016-03-15

    Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with {sup 99m}Tc and balloon brachytherapy with high-dose-rate (HDR) {sup 192}Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and methods: simulations of implants with {sup 99m}Tc-filled and HDR {sup 192}Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: the {sup 99m}Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h{sup -1}.mCi{sup -1} and 0.190 cGyh{sup -1} at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh{sup -1}.mCi{sup -1}, respectively, for the HDR {sup 192}Ir balloon. An exposure time of 24 hours was required for the {sup 99m}Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR {sup 192}Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: temporary {sup 99m}Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR {sup 192}Ir balloon implantation, which is the current standard in clinical practice. (author)

  5. Preparation of i.v. 99mTc radiopharmaceuticals from spent moly 99Mo

    International Nuclear Information System (INIS)

    Noronha, O.P.D.

    1998-01-01

    Full text: Expiry dating is an important quality assurance precept in (radio) pharmacy. There are occasions when for the sake of patient service one may be forced to continue using an over aged source of 99 Mo to generate 99m Tc beyond 7d, especially when there is short/no supply of 99 Mo, (In the early days the expiry date was 3 d or 3 extractions, whichever one was earlier). With the passage of time a few physico-chemical changes (apart from decay) do occur in the 99 Mo/ 99m Tc milieu. The cocktail also begins to contain traces of carried over MEK which is subjected to strong β-, γ irradiation. These impurity (in trace amounts) is soluble in MEK and even, to an extent, in aqueous media. Furthermore, the concentrated impurity tends to seemingly increase in the bulk 99m TcO 4 - since one is compelled to leach TcO 4 - in lower volume of saline. On many occasions we have been constrained to extend the use of 99 Mo beyond 7 - 14 d. Adequate activities were obtained by pooling the previous week's lot of 99 Mo with the current over aged lot. On a few occasions over the past 26 years we have used 99 Mo much beyond 14 d and 2 - 3 occasions for 26 - 28 d (i.e. >10 t 1 /2 of 99 Mo). On each of these occasions the purity of 99m TcO- 4 was ascertained by pharmacopoeial procedures. It was found that despite depleting activities, the purity was not compromised and the trace impurities, even if present, did not cause any interference. We have profitably utilised the bulk TcO- 4 to formulate a variety of i.v. dosage forms of 99m Tc radiodiagnostics. The following strategy was adopted for the patient services - the agents requiring larger activity levels/patients dose were made available in the earlier period, the other during the latter half. It is concluded that pure 99m TcO- 4 can be obtained over the entire useful life-period of 99 Mo, even > 10t l/2

  6. [99mTc[TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    International Nuclear Information System (INIS)

    Kung Meiping; Stevenson, D.A.; Ploessl, K.; Meegalla, S.K.; Beckwith, A.; Essman, W.D.; Mu, M.; Lucki, I.; Kung, H.F.

    1997-01-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of 99m Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel 99m Tc-labeled tropane derivative, [ 99m Tc[TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [ 99m Tc[TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, β-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [ 99m Tc[TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 μg per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [ 99m Tc[TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [ 99m Tc[TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs

  7. Characterization of sup(99m)Tc/sup(99)Tc-hydroxycarboxylic acid chelates by high voltage electrophoresis without supporting material

    International Nuclear Information System (INIS)

    Hoffmann, I.; Muenze, R.; Dreyer, I.; Dreyer, R.

    1982-01-01

    Ion mobilities of different sup(99m)Tc- and 99 Tc chelates prepared by reduction of pertechnetate by Sn(II) in the presence of citric, malic, tartaric, gluconic, and α-hydroxyisobutyric acid as ligands have been measured by means of electrophoresis without supporting material. All the chelates investigated proved to be anions in the pH range of 2-7. Both the Tc(V)- and Tc(IV) compounds with the same ligand including the sup(99m)Tc preparation show identical ion mobilities and dissociation characteristics. (author)

  8. Clinical approach to renal study incidental to {sup 99m}Tc-MDP bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Teruhiko; Onoguchi, Masahisa; Mizukami, Yuji; Koshida, Kichiro; Tsuji, Shiro [Kanazawa Univ. (Japan). School of Health Sciences; Kinuya, Seigo; Kobashi, Kazunori; Tonami, Norihisa

    2001-06-01

    In order to investigate the feasibility of the assessment of renal function with {sup 99m}Tc-MDP, we compared renographical images, renogram patterns and the glomerular filtration rate (GFR) obtained by means of a modified Gates' method and 200 MBq of {sup 99m}Tc-MDP with those obtained by means of {sup 99m}Tc-DTPA. Because 19 of 20 patients had malignant tumors in the genitourinary tract, there was no difference between the two tracers in identifying a parenchymal defect corresponding to renal cancer. Of eight patients with hydronephrosis, four had a defect or decreased uptake with a dilated pelvis, whereas the other four had marked radioisotope retention in the renal pelvis or the whole kidney on serial images. There was also no difference between the two tracers in identifying hydronephrosis. Of 38 paired renograms 35 showed the same renogram patterns with both tracers. Of three patients with different renogram patterns, two had hydronephrosis. In 20 patients including three patients with bone metastasis, total GFR and split GFR obtained with both tracers correlated with a correlation coefficient of r=0.920 (p<0.001) and r=0.944 (p<0.001), respectively. Excluding bone metastasis from the analysis, a linear-regression analysis showed excellent agreement between the two measurements with a correlation coefficient of r=0.960 (p<0.001) and r=0.963 (p<0.001), respectively. The linear regression equations were Y=1.009X - 0.111 and Y=1.034X - 0.714, respectively. In conclusion, {sup 99m}Tc-MDP can be used as a supplement to evaluate renal function incidental to the survey of bone metastases in patients with malignant tumor. (author)

  9. Phenolic aminocarboxylate chelates of 99mTc as hepatobiliary agents.

    Science.gov (United States)

    Hunt, F C; Maddalena, D J; Wilson, J G; Bautovich, G J

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[o-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with 99mTc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, 99mTc-Br-EDDHA and 99mTc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of 99mTc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  10. Sup (99m) Tc-MDP accumulation and absence of concentration of sup (99m) Tc-sulfur colloid in the spleen

    International Nuclear Information System (INIS)

    Calegaro, J.U.M.; Carvalho, A.C.M. de; Ulyssea, R.

    1984-01-01

    A case of a nine years old girl with sickle cell anemia, that showed splenic accumulation of sup (99m) Tc-MDP during bone scintigraphy is reported. On the other side, the scan with sup (99m) Tc-sulfur colloid showed no uptake in the spleen. These findings are discussed with a brief review of the pertinent literature. (Author) [pt

  11. The use of 99Mo/99mTc generators in the analysis of low levels of 99Tc in environmental samples by radiochemical methods

    International Nuclear Information System (INIS)

    Dowdall, M.; Selnaes, Oe.G.; Lind, B.; Gwynn, J.P.

    2010-01-01

    The analysis of low levels of 99 Tc in environmental samples presents special challenges, particularly with respect to the selection of an appropriate and practicable chemical yield tracer. Of all the tracers available, 99m Tc eluted from 99 Mo/ 99m Tc generators appears to be the most practicable in terms of availability, ease of use and cost. These factors have led to an increase in the use of such generators for the provision of 99m Tc as yield tracer for 99 Tc. For the analysis of low levels ( 3 or kg) of 99 Tc in environmental samples, consideration must be given to the radiochemical purity of the tracer solution with respect to contamination with both 99 Tc and other radionuclides. Due to the variable nature of the extent of the interference from tracer solution to tracer solution, it is unwise to try and establish a correction factor for any single generator. The only practical solution to the problem therefore is to run a 'blank' sample with each batch of samples drawn from a single tracer solution. (LN)

  12. The development and characterization of Tc-99m mecaptoacetyltriglycine (MAG3)

    International Nuclear Information System (INIS)

    Taylor, A. Jr.; Eshima, D.

    1990-01-01

    I-131 orth-iodohippuric (OIH) acid is a widely used renal radiopharmaceutical but it is limited due to the suboptimal imaging properties of the I-131 radionuclide and the relatively high radiation dose. Recent work has focused on the development of Tc-99m renal tubular function agents which would utilize the optimal radionuclidic properties and availability of Tc-99m, provide comparable clinical information to that obtained with OIH and allow the evaluation of renal perfusion. The triamide mercaptide (N 3 S) donor ligand system has yielded the most promising Tc-99m tubular function agent to date. Tc-99m mercaptoacetyltriglycine MAG 3 does not enter the red blood cell. A simple kit formulation has been developed which yields a stable Tc-99m MAG 3 complex in high radiochemical purity. Studies in normal volunteers and patients indicate that Tc-99m MAG 3 is an excellent Tc-99m renal tubular agent but its clearance is only 50-60% that of OIH. 42 refs., 2 tabs., 2 figs

  13. Technical artifacts in chromatographic analysis of Tc-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Creekmore, J.R.

    1982-01-01

    Technical artifacts produced during chromatographic analysis of technetium radiopharmaceuticals were investigated. Such artifacts are, we found, caused by improper spotting and drying techniques; these in turn produce spuriously high impurities in Tc-99m complexes of DTPA, MDP, PPi, and GH. The ITLC-SG/acetone system produces considerable streaking of Tc-complex if the applied spot is large and not dried before development. This results in activity in the solvent front portion of the chromatographic strip indicating falsely high levels of pertechnetate impurity. Proper drying of the applied spot eliminates the artifact. The ITLC-SG/saline system yields falsely high, hydrolyzed-reduced technetium impurities if the spot is allowed to enter the solvent during development. Correct spot placement and size eliminate this problem. Strips that are allowed to dry in room air for several minutes may indicate considerable pertechnetate impurity on the chromatogram; yet this may not actually be present in the radiopharmaceutical vial. Drying spots rapidly with hot air or in a nitrogen atmosphere before development eliminates this problem

  14. Status of {sup 99}Mo-{sup 99m}Tc production development by (n, {gamma}) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kunihiko; Kaminaga, Masanori; Ishihara, Masahiro; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Mutalib, Abdul [National Nuclear Energy Agency of Indonesia (BATAN), Tangerang (Indonesia); Chakrov, Petr [Institute of Nuclear Physics, National Nuclear Center of Republic of Kazakhstan (INP-NNC-RK), Almaty (Kazakhstan)

    2012-03-15

    Technetium-99m ({sup 99m}Tc) is one of the most commonly used radioisotopes in the field of nuclear medicine. As one of effective uses of the JMTR, JAEA has a plan to produce {sup 99}Mo by (n, {gamma}) method, a parent nuclide of {sup 99m}Tc. JAEA has performed R and D on production method of {sup 99}Mo-{sup 99m}Tc in JMTR cooperating with foreign organizations and relevant Japanese enterprises under the cooperation programs. In this paper, present status of R and D for production of {sup 99}Mo-{sup 99m}Tc in JMTR under international cooperation is introduced and constructions of the irradiation and PIE facilities at the JMTR site are also described. (author)

  15. Comparison of 99mTc-MIBI scanning and sentinel node biopsy in the detection of occult melanoma lymph node metastases

    International Nuclear Information System (INIS)

    Alonso, O.; Lago, G.; Lopes de Amorim, M.C.; Juri, C.; Larre Borges, A.; Martinez, M.; De Boni, D.; Espasandin, J.; Priario, J.

    2002-01-01

    Aim: Sentinel node biopsy (SNB) is a highly accurate technique for detecting occult metastatic disease in the regional lymph nodes. Our group has reported that 99m Tc-MIBI scintigraphy is an imaging technique that can detect clinically undetectable metastases. This prospective study shows preliminary results on the comparison of both techniques for the detection of lymph node invasion. Material and Methods: Twenty-two consecutive patients (15 women, 7 men; mean age, 55 years) with primary melanoma > 1.0 mm thick were enrolled (mean 2.6 mm). Patients underwent 99m Tc-MIBI scintigraphy of regional lymph nodes 1-2 weeks before surgery, acquiring 10-minute planar images with a LFOV gamma camera. A preoperative lymphoscintigraphy using 99m Tc-colloidal (Re) sulphide was performed the day before surgery, using a dose of 74-93 MBq. Radio guided SNB was performed with a hand-held gamma probe. Lymph nodes were examined histologically and immunostained for S-100 and HMB-45. Results: The sentinel node (SN) was identified in 21/22 patients. An average of 1.6 SN/lesion were harvested from melanomas located in the following regions: head and neck (n=3), trunk (n=6), extremities (n=12). All patients with negative SN (n=11) were also negative with MIBI. In 10 cases the SN demonstrated metastatic involvement, whereas 99m Tc-MIBI was positive in 8 of them (80%). In cases with positive SN/negative 99m Tc-MIBI, the pathology report revealed micro metastatic disease. Conclusion: These preliminary results suggest that 99m Tc-MIBI scanning has the potential of selecting a group of patients who might benefit from a selective complete lymphadenectomy

  16. A comparison of rat SPECT images obtained using 99mTc derived from 99Mo produced by an electron accelerator with that from a reactor

    International Nuclear Information System (INIS)

    Galea, R; Ross, C K; Moore, K; Wells, R G; Lockwood, J; Harvey, J T; Isensee, G H

    2013-01-01

    Recent shortages of molybdenum-99 ( 99 Mo) have led to an examination of alternate production methods that could contribute to a more robust supply. An electron accelerator and the photoneutron reaction were used to produce 99 Mo from which technetium-99m ( 99m Tc) is extracted. SPECT images of rat anatomy obtained using the accelerator-produced 99m Tc with those obtained using 99m Tc from a commercial generator were compared. Disks of 100 Mo were irradiated with x-rays produced by a 35 MeV electron beam to generate about 1110 MBq (30 mCi) of 99 Mo per disk. After target dissolution, a NorthStar ARSII unit was used to separate the 99m Tc, which was subsequently used to tag pharmaceuticals suitable for cardiac and bone imaging. SPECT images were acquired for three rats and compared to images for the same three rats obtained using 99m Tc from a standard reactor 99 Mo generator. The efficiency of 99 Mo– 99m Tc separation was typically greater than 90%. This study demonstrated the delivery of 99m Tc from the end of beam to the end user of approximately 30 h. Images obtained using the heart and bone scanning agents using reactor and linac-produced 99m Tc were comparable. High-power electron accelerators are an attractive option for producing 99 Mo on a national scale. (paper)

  17. sup(99m)Tc-labeled N-phosphoryl-aminoethyl-phosphate (sup(99m)Tc-PAEP), as bone and myocardial infarct agent. Studies in experimental animals

    International Nuclear Information System (INIS)

    Chiotellis, E.; Varvarigou, A.; Vavouraki, H.

    1982-01-01

    99m-Tc-PAEP appears as a promising new bone-seeking radiopharmaceutical. The biological experiments indicate high bone affinity and satisfactory localization in experimentally produced myocardial infarctions in rats and dogs. The data obtained suggest a further evaluation of this derivative in comparison to other technetium-phosphorus complexes

  18. The preparation of {sup 99m}Tc from {sup 99}Mo-{sup 99m}Tc using Poly-Zirconium Compound (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Laohawilai, S [Isotope Production Div., Office of Atomic Energy for Peace (Thailand)

    1998-10-01

    The process of for providing the {sup 99m}Tc-gel generator followed the protocol that received from Department of Radioisotopes, Tokai Research Establishment, JAERI. Sodium molybdate (molybdenum-99), pH 7 with concentration 20 mg/ml and activity nearly 1 mCi/ml was added into the adsorbent (PZC). The total activity of {sup 99}Mo was about 10 mCi and the heating time was varied from 3-18 hours at 70degC. The properties of the gel were studied for elution profile and elution efficiency. The molybdenum breakthrough in sodium pertechnetate (technetium-99m) was also performed. (author)

  19. Sequential hepato-biliary scintigraphy of the patients with constitutional jaundices and ICG excretory defect disease with sup(99m)Tc-HIDA and sup(99m)Tc-PI

    International Nuclear Information System (INIS)

    Ueda, Hideo; Asahara, Akira; Hishinuma, Sanpei; Toogin, Masayuki; Takagi, Masao

    1979-01-01

    The hepato-biliary scintigraphy with sup(99m)Tc-HIDA and sup(99m)Tc-PI and the measurement of hepatic clearance have been studied on constitutional hyperbilirubinemia and ICG excretory defect disease. The results obtained are as follows: 1) In Dubin-Johnson's syndrome cases, the hepatic uptake of sup(99m)Tc-HIDA was faster, but the excretion was extremely slower than in normal cases. 2) Hepatic uptake and excretion of sup(99m)Tc-PI were both almost normal in Dubin-Johnson's syndrome. 3) In Rotor's disease, hepatic uptake of sup(99m)Tc-HIDA was very poor, showing almost no hepatic image. 4) In Gilbert's disease and ICG excretory defect disease, hepatic uptake and excretion of sup(99m)Tc-HIDA were both within normal limit. From these results it can be presumed that Dubin-Johnson's syndrome and Rotor's disease differ in morbid condition. Dubin-Johnson's syndrome, Rotor's disease and Gilbert's disease show the different patterns between hepatic uptake and excretion on sup(99m)Tc-HIDA hepatoscintigraphy and the patterns contribute to the differential diagnosis of constitutional jaundice. (author)

  20. 99mTc-Hynic-minigastrin 1: a promising radiopharmaceutical for imaging gastrin/CCK-positive tumors: preclinical evaluation

    International Nuclear Information System (INIS)

    Guggenberg, E. von; Decristoforo, C.; Behe, M.; Behr, T.

    2002-01-01

    Full text: Gastrin/CCK receptors are over expressed in a number of tumors such as MW and SCLC. Therefore gastrin analogues binding to the CCK-B receptor are. promising peptides for Nuclear Medicine imaging. Recently minigastrin 1 has been labeled with 131 I, 111 In and 90 Y (Behr et al 1999). HYNIC as bifunctional chelator has shown favorable properties for 99m Tc-labeling of small peptides. The aim of this study was the preparation, 99m Tc-labeling and evaluation in vitro and in vivo of HYNIC-minigastrin 1. HYNIC-minigastrin 1 was prepared by coupling protected HYNIC to minigastrin immobilized on a resin, followed by TFA cleavage and HPLC purification. The peptide was characterized by RP-HPLC and MS. 99m Tc-labeling was performed using different coligands, such as tricine, EDDA, tricine ternary ligand systems. In vitro stability was tested in plasma and towards cystein, plasma protein binding was determined. Receptor binding assays using a CCK-B receptor positive cellline (AR42J) were performed and biodistribution in normal Wistar rats was studied with a gamma camera followed by dissection. At specific activities >1 Ci/μmol HYNIC-minigastrin 1 could be labeled with yields >95 % only using tricine as coligand. Other coligands or addition of a ternary ligand failed to give reasonable labeling yields. Two isomers of 99m Tc-tricine-HYNIC-minigastrin 1 were observed. At higher temperature quantitative yields of a stable isomer with high hydrophilicity, low protein binding and low intestinal excretion in rat biodistribution studies was obtained. Overall biodistribution in rats was similar to 111 In-DTPA-minigastrin 1 with rapid renal excretion and high kidney retention. 99m Tc-Tricine-HYNIC-minigastrin could be displaced by unlabelled Minigastrin from AR4-2J cell-membranes. A gastrin derivative could be labeled at high specific activities with 99m Tc showing isomerism dependent on labeling conditions. 99m Tc-labelled HYNIC-minigastrin 1 shows promising in vitro and in

  1. Can tumor uptake Tc-99m MDP ?

    International Nuclear Information System (INIS)

    Yand Shun, Fang; Yao, Ming; Zeng, Jun; Shi Zhen, Yu; Zhao Lan, Xiang; Dong Qiang, Gang

    2003-01-01

    To explore the mechanism of technetium-99m-methylene diphosphonate (MDP) uptake within tumor through analyze a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines ( SPC-A1 adenocarcinoma of lung cancer, Bcap-37 Breast cancer, T-24 Bladder cancer, SKOV3 Ovary carcinoma, Hela-229 Cervical carcinoma, SCI-OS Osteosarcoma, SCI-375 Melanoma) and mouse Lewis lung cancer cell line. They were transplanted into athymic mice, SCID nude mice and C57BL/6 mice, respectively. Approximately 10(6) cells of each cell line were injected subcutaneously into a right chest of mouse. After 4 and 5 weeks, the Tc-99m MDP scintigraphy were determined 6 hours after tail vein injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. According to the Region Ratio program of Siemens Power Macintosh 9500 Computer System, region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left background (T/B) and thoracic spine (T/N) of mice in Tc-99m MDP imaging. The average cpm/pixel ratios were calculated by standardized uptake measure (SUM) and determined the tumor-positive value (T/B) greater than or equal to 1.2. T/B of cell lines were sorted from higher to lower as follows: SCI-OS, Lewis, SKOV3, SCI-375, T-24, SPC-A1, Bcap-37, Hela-229. T/N: SCI-OS, SKOV3, T-24, SCI-375, Lewis, SPC-A1, Bcap-37, Hela-229. The biodistribution data of 99Tcm-MDP in SPC-A1 tumor-bearing BALB/c nude mice were given as ID/g and represent the means D (n=13) in 30 hours after injection of Tc-99m MDP. ID/g of major tissue were sorted from higher to lower as follows: thoracic spine, lumbar, ribs, kidneys, the center of tumor, the ulcer of tumor, the surrounding of tumor, lymph node, blood, lungs, heart, liver. Conclusions: Most of tumor can uptake Tc-99m MDP including human adenocarcinoma. The uptake rate in the center tissue of

  2. 99mTc-tetrapeptides: radiolabelling and biodistribution in rats

    International Nuclear Information System (INIS)

    Laznickova, A.; Laznicek, M.; Trejtnar, F.; Mather, S.J.

    1998-01-01

    Preparation of 99m Tc-labelled tetrapeptides, namely acetyl-Gly-Gly-Cys-Gly (I), acetyl-Ser-Ser-Cys-Gly (II) and acetyl-Gly-Gly-Cys-Lys (III), analysis of their radiochemical purity and biodistribution were investigated in rats. The aim was to determine the relationship between structure and biological behaviour of 99m Tc-labelled peptides which are formed by amino-acid sequences capable of chelating technetium useful as universal chelators in ''hybrid'' peptides composed of receptor-specific part and the part chelating technetium. For labelling with 99m Tc, a conventional transchelation from 99m Tc-gluconate was used and radiolabelled peptides were purified by filtration on Whatman microfilters 12 kD. Radiochemical purity was higher than 98%. Biodistribution studies in rats showed that all agents are rapidly cleared from the body mostly via urine, but some part of administered radioactivity also in the faces was found. The later route of elimination way increased in the order III 99m Tc-MAG3. The results obtained will assist with design of optimal biocompatible tetrapeptides as chelators for formation of hybrid receptor-specific peptides. (author)

  3. The trend of 99mTc generator in FNCA countries

    International Nuclear Information System (INIS)

    Genka, Tsuguo; Machi, Sueo

    2004-01-01

    In the 2001 Workshop on Utilization of Research Reactors held in Beijing, eight delegates from the FNCA countries, namely China, Indonesia, Japan, Korea, Malaysia, the Philippines, Thailand and Vietnam, for the 99m Tc Generator Project, presented papers or orally pleaded the current status of utilization and production in terms of 99 Mo solution, 99 Mo/ 99m Tc generator or extracted 99m Tc solution in each country. This paper is a brief compilation of these topics and some additional information obtained afterward the workshop. (author)

  4. Morphological classification of Renal Disease Using 99mTc-DMSA Scintigram

    International Nuclear Information System (INIS)

    Moon, Tae Yong

    1991-01-01

    99m Tc-DMSA renal scan has been evaluated not only the renal functional cell mass but also some anatomical structures at a loss of the renal parenchymal function. The author classified a renal morphology of the posterior image of 99m Tc-DMSA renal scan as the groups of symmetic and asymmetric morphology, the groups of the large, normal and small sized kidneys, the groups of the central photon defects (PD) which could be noted in a dilated pelvocalyceal system due to obstructive uropathy and the cortical photon defects (CD) due to focal parenchymal lesions or scars after a loss of function and the last groups of the single and multiple CD for a suggestion of the clinical usefulness. Regarding to measurement of norrnal renal size, the longest size of the kidneys were evaluated with 5 cm of a lead scale on the posterior renal image, and those were decided to the limits beteen 104.1 and 119. 4 mm as comparison with the renal size of intravenous pyelogram (IVP) in 59 cases who were underwent 99m Tc-DMSA and IVP concommitantly. Among 85 cases of PD in 99m Tc-DMSA renal scan, the 61 (71.8%) were cases of a dilated pelvocalyceal system related with obstructive uropathy, meanwhile the 28 (27.0%) of 162 cases with CD were cases of obstructive and infectious uropathy. The probability of a presence of some uropathy in cases of CD were 99.3%, meanwhile that of the presence of CD in cases of some uropathy were 37.9%. Besides, there were some specific anatomical findings such as polycystic kidneys with symmetric enlarged kidneys with multiple CD and the kidneys of chronic renal failure and/or hypertension with syrnmetric small size in 99m Tc-DMSA renal scan.

  5. A novel electrochemical technique for the production of clinical grade 99mTc using (n, γ)99Mo

    International Nuclear Information System (INIS)

    Chakravarty, Rubel; Dash, Ashutosh; Venkatesh, Meera

    2010-01-01

    Introduction: In order to meet the growing demand for 99m Tc and to reduce the reliance on fission-produced 99 Mo, an electrochemical pathway for accessing 99m Tc through the (n, γ) 99 Mo was explored as a back-up measure and to supplement 99m Tc supply for radiopharmaceuticals application. Methods: 99m Tc from an equilibrium mixture of 99 Mo/ 99m Tc was selectively deposited on a platinum cathode in an electrochemical cell by applying optimal voltage and stripped back again into the 0.9% saline solution. The radiochemical and radionuclidic purity of the product were determined using standard techniques. 99m Tc thus obtained was used for labeling standard ligands such as dimercaptosuccinic acid (DMSA) and ethylene dicysteine (EC), to ascertain the usability. Results: Selective deposition of 99m Tc on the platinum electrode was achieved at a potential of 5 V over a period of 1 h in NaOH electrobath. The overall yield of 99m Tc was >90%, with >99.99% radionuclidic purity and >99% radiochemical purity. The performance of the generator remained consistent over a period of 10 days. The compatibility of the product in the preparation of 99m Tc-labeled formulations such as 99m Tc-DMSA and 99m Tc-EC was found to be satisfactory in terms of high labeling yields (>98%). Conclusion: A novel and attractive method has been developed to obtain highly concentrated 99m Tc, without using fission-produced 99 Mo.

  6. Detection of sites of infection in mice using 99mTc-labeled PN2S-PEG conjugated to UBI and 99mTc-UBI: a comparative biodistribution study

    International Nuclear Information System (INIS)

    Melendez-Alafort, Laura; Nadali, Anna; Pasut, Gianfranco; Zangoni, Elena; De Caro, Raffaele; Cariolato, Luca; Giron, Maria Cecilia; Castagliuolo, Ignazio; Veronese, Francesco M.; Mazzi, Ulderico

    2009-01-01

    The antimicrobial peptide ubiquicidin (UBI) directly labeled with technetium-99m ( 99m Tc) has recently been shown to be specifically taken up at sites of infection; however, its chemical structure is not well defined. To address this problem, the aim of the present study was to label UBI using poly(ethyleneglycol)-N-(N-(3-diphenylphosphinopropionyl)glycyl) -S-tritylcysteine ligand (PEG-PN 2 S) in order to compare its ability to detect infection sites with that of 99m Tc-UBI. Methods: The PN 2 S-PEG-UBI conjugate was prepared and labeled with 99m Tc, and its radiochemical purity was subsequently assessed. The stability of the conjugate to cysteine challenge and dilution with both saline solution and phosphate buffer was determined and serum stability and protein binding were also assessed. In vivo studies were carried out in healthy mice to study the biodistribution of 99m Tc-PN 2 S-PEG-UBI and its precursor 99m Tc-PN 2 S-PEG and in infected mice to compare the uptakes of 99m Tc-UBI and 99m Tc-PN 2 S-PEG-UBI at the site of infection using scintigraphic imaging and ex vivo tissue counting. Results: 99m Tc-PN 2 S-PEG-UBI was obtained with high radiochemical purity (98±1%) and high stability. The amphiphilic nature of the conjugate leads to a tendency to form micellar aggregates that explain the high protein binding values obtained. Biodistribution studies in mice showed low renal clearance followed by a predominant reticuloendothelial system clearance that limits its application in the abdominal area. Statistical analysis revealed no significant difference between 99m Tc-UBI and 99m Tc-PN 2 S-PEG-UBI uptake in infected mouse thigh, and the site of infection was clearly visualized using scintigraphic imaging. Conclusions: 99m Tc-PN 2 S-PEG-UBI proved to be as effective as 99m Tc-UBI in detecting sites of infection; however, the well-defined chemical structure of 99m Tc-PN 2 S-PEG-UBI makes it a better candidate for clinical imaging of infection

  7. 99mTc complexes of 1,3-propanedithiol derivatives

    International Nuclear Information System (INIS)

    Alagui, A.; Apparu, M.; Vidal, M.; Mathieu, J.P.

    1987-01-01

    The labelling of 1,3-n alkylpropanedithiols and of 15-(1,3-dimercapto 2-propyl)pentadecanoic acid by 99m Tc was performed by an exchange reaction with the hexachlorotechnetate ion 99m TcCl 6 2- and by reduction of 99m TcO 4 - with Sn(II) in the presence of the ligand. The biological distribution of the exotechnetium complexes obtained by the latter method in mouse does not reveal a high tropism of these labelling compounds in relation to a particular tissue. (author) 14 refs.; 2 tabs

  8. Magnesium-Molybate Compounds as Matrix for 99Mo/99mTc Generators

    Directory of Open Access Journals (Sweden)

    Fabiola Monroy-Guzman

    2011-01-01

    Full Text Available This work reports the preparation of a 99mTc generator based on conversion of 99Mo produced by neutron irradiation, into insoluble magnesium 99Mo-molybdates compounds as matrix. The effect of magnesium salt types and concentration, Mg:Mo molar ratios, pH of molybdate solutions, eluate volume as well as the addition order of molybdate and magnesium solutions’ influences on the final 99mTc were evaluated. Polymetalates and polymolybdates salts either crystallized or amorphous were obtained depending on the magnesium salt and Mg:Mo molar ratio used in matrix preparation. 99Mo/99mTc generator production based on magnesium-99Mo molybdate compounds allow reduction of preparation time and eliminates the use of specialized installations. The best generator performances were attained using matrices prepared from 0.1 mol/L MgCl2·6H2O solutions, ammonium molybdate solutions at pH 7 and at a Mg:Mo molar ratio of 1:1.

  9. Quantitation of the intrahepatic shunt index by injection of 99mTc-macroaggregated albumin into the spleen

    International Nuclear Information System (INIS)

    Saito, Masaaki; Ohnishi, Kunihiko; Katsurai, Hiroshi; Tanaka, Hideo; Chin, Nobuyoshi; Iida, Shinji; Nomura, Fumio; Okuda, Kunio

    1987-01-01

    The accuracy of the intrahepatic shunt index measured by injection of 99m Tc-macroaggregated albumin into the spleen was assessed in comparison with the intrahepatic shunt index measured by injection of 99m Tc-macroaggregated albumin into the portal trunk in 28 patients with portal hypertension. 99m Tc-macroaggregated albumin was injected through the catheter into the portal trunk and the intrahepatic shunt index was calculated by counting over predetermined areas of the liver and lungs. Injection of 99m Tc-macroaggregated albumin into the spleen was performed between one or two weeks before portal vein catheterization, and the calculation of the intrahepatic shunt index was performed with a scinticamera and ROI-radiograms obtained by data-processing. There was a significant correlation between the intrahepatic shunt index calculated by injection of 99m Tc-macroaggregated albumin into the spleen and that by injection of 99m Tc-macroaggregated albumin into the portal trunk (r = 0.90, p < 0.001). (author)

  10. Comparison of Tc-99m-sestamibi-F-18-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress Tc-99m-sestamibi single photon emission computed tomography for the assessment of myocardial viability

    NARCIS (Netherlands)

    De Boer, J; Slart, RHJA; Blanksma, Paulus; Willemsen, ATM; Jager, PL; Paans, AMJ; Vaalburg, W; Piers, DA

    Dual isotope simultaneous acquisition single photon emission computed tomography (DISA SPECT) offers the advantage of obtaining information on myocardial perfusion using Tc-99m-sestamibi (Tc-99m-MIBI) and metabolism using F-18-fluorodeoxyglucose (F-18-FDG) in a single study. The prerequisite is that

  11. Comparison of thallium-201 scan and Tc-99m sestamibi scan in the differential diagnosis of breast mass

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Won, Kyu Jang; Lee, Hyung Woo; Lee, Soon Jung [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1999-02-01

    We performed this study to compare Tl-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Thirty-eight female patients underwent Tl-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of Tl-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared Tl-201 and Tc-99m MIBI scans with pathologic results. Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed Tl-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18/20), respectively. The sensitivity of early Tl-201 scan was significantly higher than that of delayed Tl-201 scan, (p<0.05). The specificity of early and delayed Tl-201 scan and Tc-99m MIBI scan were 73% (11/15), 73% (11/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed Tl-201 scans. The size of fibroadenoma with false positive in early and delayed Tl-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early Tl-201 images, 15% (2/13) for delayed Tl-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed Tl-201 images (p<0.05). Early Tl-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast. Tc-99m MIBI scan was sensitive in detecting axillary lymph node

  12. Rapid radiochemical methods for preparation of sup(99m)Tc labelled compounds

    International Nuclear Information System (INIS)

    Narasimhan, D.V.S.; Banodkar, S.M.; Kothari, K.; Mani, R.S.

    1981-01-01

    Several inorganic and organic compounds incorporating sup( 99 m)Tc are being extensively used for imaging various body organs. The preparation of these sup( 99 m)Tc compounds with the necessary purity requirements is carried out by controlled reduction of sup( 99 m)Tc-pertechnetate using Sn(II) ions as the reducing agent followed by complexation with various active ingredients. The authors here present procedures developed at Radiopharmaceuticals Section of BARC for preparing sup( 99 m)Tc-diphosphonate, sup( 99 m)Tc-glucoheptonate, sup( 99 m)Tc-albumin microspheres and sup( 99 m)Tc-phytate with high radiochemical purity. The paper also describes procedures for the preparation of freeze-dried kits for single step preparation of these compounds. The paper also describes the authors' experience with various analytical procedures for the determination of radiochemical purity of these preparations. (author)

  13. Evaluation of {sup 99m}Tc(CO){sub 5}I as a potential lung perfusion agent

    Energy Technology Data Exchange (ETDEWEB)

    Miroslavov, Alexander E.; Gorshkov, Nikolay I.; Lumpov, Alexander L. [Division of Radiochemical Research, Khlopin Radium Institute, 2nd Murinskii pr. 28, 194021, St Petersburg (Russian Federation); Yalfimov, Anatoly N. [Nuclear Medicine Department, Central Research Institute of Roentgenology and Radiology, Leningradskaya str. 70/4, 197000, St Petersburg (Russian Federation); Suglobov, Dmitrii N. [Division of Radiochemical Research, Khlopin Radium Institute, 2nd Murinskii pr. 28, 194021, St Petersburg (Russian Federation); Ellis, Beverley L. [Department of Nuclear Medicine, Manchester Royal Infirmary, M13 9WL Manchester (United Kingdom)], E-mail: bev.ellis@manchester.ac.uk; Braddock, Rattana; Smith, Anne-Marie [Imaging Science and Biomedical Engineering, School of Cancer and Imaging Science, Stopford Building, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom); Prescott, Mary C.; Lawson, Richard S. [Department of Nuclear Medicine, Manchester Royal Infirmary, M13 9WL Manchester (United Kingdom); Sharma, Harbans L. [Imaging Science and Biomedical Engineering, School of Cancer and Imaging Science, Stopford Building, The University of Manchester, Oxford Road, Manchester M13 9PT (United Kingdom)

    2009-01-15

    Introduction: The use of {sup 99m}Tc-macroggregated albumin for lung perfusion imaging is well established in nuclear medicine. However, there have been safety concerns over the use of blood-derived products because of potential contamination by infective agents, for example, Variant Creutzfeldt Jakob Disease. Preliminary work has indicated that Tc(CO){sub 5}I is primarily taken up in the lungs following intravenous administration. The aim of this study was to evaluate the biodistribution and pharmacokinetics of {sup 99m}Tc(CO){sub 5}I and its potential as a lung perfusion agent. Methods: {sup 99m}Tc(CO){sub 5}I was synthesized by carbonylation of {sup 99m}TcO{sub 4-} at 160 atm of CO at 170 deg. C in the presence of HI for 40 min. Radiochemical purity was determined by HPLC using {sup 99}Tc(CO){sub 5}I as a reference. {sup 99m}Tc(CO){sub 5}I was administered by ear-vein injection to three chinchilla rabbits, and dynamic images were acquired using a gamma camera (Siemens E-cam) over 20 min. Imaging studies were also performed with {sup 99m}Tc-labeled macroaggregated albumin ({sup 99m}Tc-MAA) and {sup 99m}TcO{sub 4-} for comparison. {sup 99m}Tc(CO){sub 5}I was administered intravenously to Sprague-Dawley rats, and tissue distribution studies were obtained at 15 min and 1 h postinjection. Comparative studies were performed using {sup 99m}Tc-MAA. Results: Radiochemical purity, assessed by HPLC, was 98%. The retention time was similar to that of {sup 99}Tc(CO){sub 5}I. The dynamic images showed that 70% of {sup 99m}Tc(CO){sub 5}I appeared promptly in the lungs and remained constant for at least 20 min. In contrast, {sup 99m}TcO{sub 4-} rapidly washed out of the lungs after administration. As expected {sup 99m}Tc-MAA showed 90% lung accumulation. The percentage of injected dose per gram of organ {+-}S.D. at 1 h for {sup 99m}Tc(CO){sub 5}I was as follows: blood, 0.22{+-}0.02; lung, 12.8{+-}2.87; liver, 0.8{+-}0.15; heart, 0.15{+-}0.01; kidney, 0.47{+-}0.08. The

  14. 99mTc-ECD: Comparison of radiochemical purity evaluation techniques

    International Nuclear Information System (INIS)

    Dumont, A.; De Beco, V.; Ait Ben Ali, S.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Lours, S.; Moati, F.; Pajard, D.; Piketty, M.L.; Rizzo, N.; Schlageter, M.H.; Moretti, J.L.

    1997-01-01

    The aim of this study was to validate a testing method for the radiochemical purity (RCP) of the preparations of 99m Tc - ECD that is to be reproducible and easy to realize in services of Nuclear Medicine. After a review of literature, four thin-layer chromatography techniques allowing to evidence the TcO 4 - were evaluated: no.1 - Papier Whatman 31ET / ethyl acetate; no.2 - Papier Whatman 3MM chr / ethyl acetate; no.3 - ITLC Silica gel / ethyl acetate; no.4 - Baker Flex silica gel aluminium oxide IB-F / ethyl acetate (the method proposed by the laboratory). The technique no.1 has presented a bad reproducibility, as well as percentages of RCP very different from those obtained by the other techniques. The techniques no.2 and no.3, although rapid, are characterized by lower reproducibilities in comparison with technique no.4, with, some times, peaks of undetermined nature on the radio-chromatograms no.3. So, in spite of a slower migration (10 min.) the technique no.4 has been selected from the group as the most reliable technique. For this technique, the comparison between the two modes of reading the chromatography (by means of a radio-chromatograph or by measuring the activity of the two halves of the plate by an activity-meter), has shown no significant difference in RCP. Consequently, this method (Baker Flex / ethyl acetate) may by adapted in any service of nuclear medicine, no matter of its equipment

  15. Synthesis, characterization and biodistribution of technetium complexes (99Tc/99mTc) with 2-amino-2-deoxy-D-hexose oximes

    International Nuclear Information System (INIS)

    Steinmetz, H.J.

    1993-05-01

    In the present work, the synthesis and isolation of isomeric complexes of technetium ( 99 Tc/ 99m Tc) with the 2-amino-2-deoxy-D-hexoses D-glucose aminoxime, D-galactose aminoxime and D-mannose aminoxime, the characterization of the complexes as 99 Tc compounds, and bio-distribution studies on the analogous 99m Tc complexes have been untertaken. As a first step, the free ligands were synthesized and identified using elemental analysis, infra-red and nuclear magnetic resonance spectroscopy and FAB mass spectroscopy. In the bio-distribution studies on the 99m Tc complexes of D-glucose aminoxime and of D-galactose aminoxime in NMRI mice, significant short-term accumulation of 99m Tc activity in heart muscle could be detected, which may be attributed to a biochemical transport mechanism. Uptake in the lungs and the liver was found, but a more significant uptake was observed in the kidneys, where the complexes were rapidly secreted in proportion to their concentration in the blood plasma. (orig./BBR) [de

  16. Synthesis quality control and biodistribution of technetium-99m triamcinolone (99mTc-TA) complex: An inflammation tracer agent

    International Nuclear Information System (INIS)

    Rizvii, Faheem Askari; Naqvi, Syed Ali Raza; Mehdi, Muhammad; Roohi, Samina; Zahoor, Ameer Fawad; Khan, Zulfiqar Ali; Sohaib, Muhammad; Rasheed, Rashid

    2017-01-01

    In present study synthesis of 99m Tc-triamcinolone acetonide ( 99m Tc-TA) complex and its stability using set of quality control parameters such as ligand concentration, reducing agent concentration, pH, temperature and reaction time was assessed. 99m Tc-TA complex was characterized in terms of percent (%) yield, stability in saline and serum using chromatographic procedures. Radiochemically the 99m Tc-TA complex was found quite stable in saline and serum. After 30 min of reaction the complex showed maximum radiochemical yield of 96.32% which decreased to 96.25 % after 4 h incubation period. In serum, the % yield of radiochemical was remained same up to 2 h which decreased to 93.5% at 24 h time point. Normal biodistribution pattern in Sprague-Dawley rats revealed liver, stomach and kidneys as areas of high 99m Tc-TA complex uptake (8.44 ±1.32, 8.75 ± 1.03 and 12.67 ± 1.21%, respectively) at 1 h post injection time point. Scintigraphy of 99m Tc-TA in rabbits showed similar eco as observed in biodistribution study. Based on the promising results obtained in context of in vitro and in vivo stability and biodistribution, 99m Tc-TA complex could be further studied to identify the inflammation based diseases

  17. Recent achievements in Tc-99m radiopharmaceutical direct production by medical cyclotrons.

    Science.gov (United States)

    Boschi, Alessandra; Martini, Petra; Pasquali, Micol; Uccelli, Licia

    2017-09-01

    99m Tc is the most commonly used radionuclide in the field of diagnostic imaging, a noninvasive method intended to diagnose a disease, assess the disease state and monitor the effects of treatments. Annually, the use of 99m Tc, covers about 85% of nuclear medicine applications. This isotope releases gamma rays at about the same wavelength as conventional X-ray diagnostic equipment, and owing to its short half-life (t ½  = 6 h) is ideal for diagnostic nuclear imaging. A patient can be injected with a small amount of 99m Tc and within 24 h almost 94% of the injected radionuclide would have decayed and left the body, limiting the patient's radiation exposure. 99m Tc is usually supplied to hospitals through a 99 Mo/ 99m Tc radionuclide generator system where it is produced from the β decay of the parent nuclide 99 Mo (t ½  = 66 h), which is produced in nuclear reactors via neutron fission. Recently, the interruption of the global supply chain of reactor-produced 99 Mo, has forced the scientific community to investigate alternative production routes for 99m Tc. One solution was to consider cyclotron-based methods as potential replacement of reactor-based technology and the nuclear reaction 100 Mo(p,2n) 99m Tc emerged as the most worthwhile approach. This review reports some achievements about 99m Tc produced by medical cyclotrons. In particular, the available technologies for target design, the most efficient extraction and separation procedure developed for the purification of 99m Tc from the irradiated targets, the preparation of high purity 99m Tc radiopharmaceuticals and the first clinical studies carried out with cyclotron produced 99m Tc are described.

  18. Organ distribution of sup(99m)Tc-Sn tetracycline antibiotics in rats

    International Nuclear Information System (INIS)

    Kalincak, M.; Machan, V.; Barna, K.

    1976-01-01

    The organ distribution of [sup(99m)Tc-Sn]tetracycline hydrochloride, [sup(99m)Tc-Sn]oxytetracycline hydrochloride and [sup(99m)Tc-Sn]rolitetracycline nitrate was studied in rats. It was shown that these preparations have a very similar organ distribution and are predominantly deposited in the kidneys. The maximum renal radioactivity level was found 2 to 4 hours after intravenous administration of the preparation, this, for [sup(99m)Tc-Sn]tetracycline hydrochloride 18.60%; for [sup(99m)Tc-Sn]oxytetracycline hydrochloride 17.09.=.; for [sup(99m)Tc-Sn]rolitetracycline nitrate 20.12%. The activity levels in the muscle, liver, heart, brain, lungs, stomach and spleen are minimal. (author)

  19. Organ distribution of /sup 99m/Tc--Sn tetracycline antibiotics in rats

    Energy Technology Data Exchange (ETDEWEB)

    Kalincak, M; Machan, V; Barna, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Lekarska Fakulta

    1976-06-01

    The organ distribution of (sup(99m)Tc-Sn)tetracycline hydrochloride, (sup(99m)Tc-Sn)oxytetracycline hydrochloride and (sup(99m)Tc-Sn)rolitetracycline nitrate was studied in rats. It was shown that these preparations have a very similar organ distribution and are predominantly deposited in the kidneys. The maximum renal radioactivity level was found 2 to 4 hours after intravenous administration of the preparation, this, for (sup(99m)Tc-Sn)tetracycline hydrochloride 18.60%; for (sup(99m)Tc-Sn)oxytetracycline hydrochloride 17.09.=.; for (sup(99m)Tc-Sn)rolitetracycline nitrate 20.12%. The activity levels in the muscle, liver, heart, brain, lungs, stomach and spleen are minimal.

  20. Targeted functional imaging of estrogen receptors with 99mTc-GAP-EDL

    International Nuclear Information System (INIS)

    Takahashi, Nobukazu; Yang, David J.; Kohanim, Saady; Oh, Chang-Sok; Yu, Dong-Fang; Azhdarinia, Ali; Kurihara, Hiroaki; Kim, E.E.; Zhang, Xiaochun; Chang, Joe Y.

    2007-01-01

    To evaluate the feasibility of using 99m Tc-glutamate peptide-estradiol in functional imaging of estrogen receptor-positive [ER(+)] diseases. 3-Aminoethyl estradiol (EDL) was conjugated to glutamate peptide (GAP) to yield GAP-EDL. Cellular uptake studies of 99m Tc-GAP-EDL were conducted in ER(+) cell lines (MCF-7, 13762 and T47D). To demonstrate whether GAP-EDL increases MAP kinase activation, Western blot analysis of GAP-EDL was performed in 13762 cells. Biodistribution was conducted in nine rats with 13762 breast tumors at 0.5-4 h. Each rat was administered 99m Tc-GAP-EDL. Two animal models (rats and rabbits) were created to ascertain whether tumor uptake of 99m Tc-GAP-EDL was via an ER-mediated process. In the tumor model, breast tumor-bearing rats were pretreated with diethylstilbestrol (DES) 1 h prior to receiving 99m Tc-GAP-EDL. In the endometriosis model, part of the rabbit uterine tissue was dissected and grafted to the peritoneal wall. The rabbit was administered with 99m Tc-GAP-EDL. There was a 10-40% reduction in uptake of 99m Tc-GAP-EDL in cells treated with DES or tamoxifen compared with untreated cells. Western blot analysis showed an ERK1/2 phosphorylation process with GAP-EDL. Biodistribution studies showed that tumor uptake and tumor-to-muscle count density ratio in 99m Tc-GAP-EDL groups were significantly higher than those in 99m Tc-GAP groups at 4 h. Among 99m Tc-GAP-EDL groups, region of interest analysis of images showed that tumor-to muscle ratios were decreased in blocking groups. In the endometriosis model, the grafted uterine tissue could be visualized by 99m Tc-GAP-EDL. Cellular or tumor uptake of 99m Tc-GAP-EDL occurs via an ER-mediated process. 99m Tc-GAP-EDL is a useful agent for imaging functional ER(+) disease. (orig.)

  1. Usefulness of 99mTc-ECD SPECT in diseases of central nerve system

    International Nuclear Information System (INIS)

    Ono, Shimato; Yanagimoto, Shinichi; Mimura, Hiroaki

    1992-01-01

    The usefulness of a new cerebral perfusion imaging radiopharmaceutical, 99m Tc-ethyl cysteinate dimer (ECD), was clinically evaluated. The subjects of this study were 14 patients with neurological disorders including 10 patients with cerebral infarction and 4 patients with other diseases. A total of 15 examinations was performed. 99m Tc-hexamethylpropyleneamine oxime ( 99m Tc-HM-PAO) or 123 I-N-isopropyl-p-iodoamphetamine ( 123 I-IMP) SPECTs were performed simultaneously, and the findings from those examinations were compared with 99m Tc-ECD. As to the count ratio of lesions to normal area (L/N), the L/N ratio in severe ischemic patients was lower in 99m Tc-ECD than in 99m Tc-HM-PAO or 123 I-IMP. In mild ischemic patients, on the other hand, the L/N ratio was the lowest in 123 I-IMP. When the relationship between regional cerebral blood flows (rCBFs) obtained from 123 I-IMP and the values of L/N in 99m Tc-ECD or 99m Tc-HM-PAO was compared, the values of L/N in 99m Tc-ECD or 99m Tc-HM-PAO were found to have decreased linearity with increasing rCBF. In a patient showing luxury perfusion, the accumulation pattern of 99m Tc-ECD was different from that of the other two radiopharmaceuticals, and focal defect was revealed in 99m Tc-ECD SPECT. On the dynamic SPECT of 99m Tc-ECD in a patient with meningioma, the tumor showed a change from high to low perfusion with the passage of time. This finding indicated that care should be taken in the evaluation of accumulation of 99m Tc-ECD. Therefore, 99m Tc-ECD was found to be useful as a cerebral perfusion agent. In addition, as accumulation of 99m Tc-ECD might somehow reflect metabolism in some cases, further careful investigation of many cases should be carried out. (author)

  2. Improved kit formulation for preparation of (99m)Tc-HYNIC-TOC: results of preliminary clinical evaluation in imaging patients with neuroendocrine tumors.

    Science.gov (United States)

    Korde, Aruna; Mallia, Madhava; Shinto, Ajit; Sarma, H D; Samuel, Grace; Banerjee, Sharmila

    2014-11-01

    (99m)Tc-HYNIC-TOC is a cost-effective and logistically viable agent for scintigraphy of neuroendocrine tumors overexpressing somatostatin receptors as compared with [(111)In-DTPA-D-Phe(1)] Octreotide (Octreoscan(®)). Several studies have been reported, wherein the efficacy of this agent is demonstrated. In the present article, the authors report the preparation of a single-vial HYNIC-TOC kit suitable for the preparation of 4-5 patient doses (15 mCi/patient) of (99m)Tc-HYNIC-TOC. The kits were tested for sterility and bacterial endotoxins to assure safety of the product. A significant modification in this kit is the inclusion of buffer in the kit itself, unlike in commercially available kits where the buffer solution has to be added during preparation. (99m)Tc-HYNIC-TOC was prepared by adding 20-80 mCi (740-2960 MBq) of freshly eluted Na(99m)TcO4 in 1-3 mL of sterile saline directly into the kit vial and heating the vial in a water bath at 100°C for 20 minutes. The labeling yield and radiochemical purity of (99m)Tc-HYNIC-TOC, prepared using the lyophilized cold kit, were consistently >90%. The kits were evaluated over a period of 9 months and found to be stable when stored at -20°C. Limited clinical studies performed with the (99m)Tc-HYNIC-TOC, formulated using the kit, showed adequate sensitivity and specificity for the detection of gasteroenteropancreatic neuroendocrine tumors.

  3. Preparation of 99mTc-thiourea complex as a precursor for Tc(III) labeled compounds

    International Nuclear Information System (INIS)

    Rey, A.; Teran, M.; Molina, S.; Leon, A.; Kremer, C.; Gambino, D.; Kremer, E.

    1996-01-01

    Ligand exchange is one of the possible synthetic routes to obtain 99m Tc coordination compounds. However, the success of this route depends on the availability of good precursors. The objective of this work is the preparation of the complex [ 99m Tc (tu) 6 ] 3+ (tu = thiourea), as a potential precursor for 99m Tc(III) coordination compounds. The preparation was successfully performed in acidic conditions, the excess of tu serving as reducing agent. At pH values higher than 3, the compound becomes unstable and on addition of polydentate ligands new Tc(III) complexes are formed. With edta, the complex 99m Tc(III)-edta was obtained in high yield. (author). 13 refs., 3 tabs

  4. Process modifications of obtaining Tc-99m by solvent extraction

    International Nuclear Information System (INIS)

    Leon, A.; Verdera, S.

    1978-01-01

    This paper describes a modification in the process to obtaining Tc-99m by the extraction method of solvent from Mo-99 produced by irradiation. Tc-99m is considered an ideal radionuclide for medical and biological applications

  5. Sodium metabisulfite: a new reducer agent for direct labelling of immunoglobulins with 99mTc

    International Nuclear Information System (INIS)

    Zayas, F.; Hernandez, T.; Rodriguez, M.E.; Perera, A.; Hernandez, L.; Valdes, M.

    1998-01-01

    A method for direct labeling of antibodies with 99mTc is described. Sodium Metabisulfite (SMB) was evaluated as a new reducing agent of disulfide bridges of the IgG molecule. Under selected experimental conditions, radiochemical purities of the label higher than 90.0% were achieved in most of the experiments. On the basis of the obtained yields an empiric equation which describes the system was computed as: Y=93.6+2.1X5 - 1.36X6+0.9X7. The absence of X4 indicated that the purification on Sephadex of the reduced IgG was not relevant to the labeling process. The most important variables were tin ion concentration (X5), the volume of Tin-Tartrate solution (X6) and the incubating time between reduced IgG and Tin-Tartrate solution (X7). A low aggregation and fragmentation of the IgG molecule was obtained when a SMB/IgG molar relation of 750/1 was used. The stability of the 99mTc-IgG was assessed by DTPA, HSA and L-Cysteine challenge studies. An acceptable level of dissociation was observed in presence of DTPA and L-Cysteine, when the Tartrate anion was used. However the transchelation level for HSA was about 80.0 per cent. These preliminary results showed that SMB could be a useful reducing agent for direct labeling of IgG. Further studies are needed to correctly evaluate it. (author)

  6. Synthesis and formulation of 99m Tc-ECD radiopharmaceutical

    International Nuclear Information System (INIS)

    Ocampo G, B.E.

    1998-01-01

    Nuclear medicine is a medical specialty which uses radioactive compounds (radionuclides) for diagnostic and therapeutic purposes. 99m Tc is the more common radionuclide used in many studies in nuclear medicine because its advantages: it has a photopeak of 140 KeV and a half-life of 6 hours; it can be eluted from a Molybdenum 99 generator, so radiopharmaceuticals can be prepared on site. Ethyl cysteine dimer (ECD) labelled with reduced Technetium 99m has been purposed recently as a promising radiopharmaceutical for brain perfusion imaging 99m Tc-ECD is a lipophilic neutral complex which cross the brain blood barrier and show high brain uptake. The objective of this work was synthesize and to design a freeze dried formulation for the instant preparation of 99m Tc-ECD complex useful for brain perfusion imaging. We obtained a freeze dried stable formulation for the preparation of 99m Tc-ECD kit with a radiochemical purity higher than 90 %, which fulfills with the quality control of radiopharmaceuticals. Furthermore, we developed analytic techniques for the determination of the different chemical compounds into the lyophilized kit. (Author)

  7. Model-based comparison of maternal and foetal organ doses from {sup 99m}Tc pertechnetate, DMSA, DTPA, HDP, MAA and MAG{sub 3} diagnostic intakes during pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Margaret; Palmer, Maria; Preece, Alan; Millard, Roger [Centre for Physics and Engineering Research in Medicine, University of Bristol, Bristol Oncology Centre, Horfield Road, Bristol BS2 8ED (United Kingdom)

    2002-10-01

    Organ residence times were calculated for diagnostic intakes of {sup 99m}Tc pertechnetate, 2,3-dimercaptosuccinic acid (DMSA), diethylene triamine penta-acetic acid (DTPA), hydroxymethylene diphosphonate (HDP), macroaggregated albumin (MAA) and mercapto-acetyltriglycine (MAG{sub 3}) during the 1st and 3rd stages of pregnancy and used with the MIRDOSE3 pregnant female phantoms for generation of dose estimates. At stage 3 individual foetal organ doses were estimated via a surrogate phantom based on that for the new-born but with mean dose/cumulated activity (S) values scaled for compatibility with foetal whole body S. Stage 1 or 3 whole foetus doses ranged from 5.2 to 0.77 {mu}Gy MBq{sup -1} respectively, analogous to current ICRP estimates for these agents using similar in vivo biodistribution model databases. Most stage 3 maternal and foetal organ doses were similar within a factor of 3, being higher in the foetus than the mother with pertechnetate, DTPA and MAG{sub 3}, and lower with DMSA, HDP and MAA. Doses were more uniformly distributed among foetal organs than in the mother. Placental transfer was greatest with pertechnetate, where dose to the stage 3 foetal thyroid was 60-140 {mu}Gy MBq{sup -1}. With each agent there was more placental transfer in stage 3 than in stage 1, but doses to stage 1 whole foetus were always higher, with the contribution from the mother dominant. For DMSA, HDP and MAG{sub 3} the maternal contribution to total foetal body dose exceeded 93% for both stages. (orig.)

  8. Platelet binding and biodistribution of [99mTc]rBitistatin in animal species and humans

    International Nuclear Information System (INIS)

    Knight, Linda C.; Romano, Jan E.; Bright, Lewis T.; Agelan, Alexis; Kantor, Steven; Maurer, Alan H.

    2007-01-01

    Introduction: 99m Tc recombinant bitistatin (rBitistatin) is a radioligand for α IIb β 3 (glycoproteins IIb/IIIa) receptor on platelets and is being developed as a diagnostic radiopharmaceutical for in vivo imaging of acute thrombi and emboli. Prior to the first administration of [ 99m Tc]rBitistatin to human subjects, its biodistribution and effects on platelets were evaluated in animals. This paper reports findings in animal studies in comparison with initial findings in normal human subjects. Methods: [ 99m Tc]rBitistatin was administered to mice, guinea pigs and dogs to assess time-dependent organ distribution, urinary excretion and blood disappearance rates. Blood samples were analyzed to determine radioligand binding to circulating platelets and the extent of plasma protein binding. The effect of [ 99m Tc]rBitistatin on circulating platelet count was determined. These factors were also determined in normal human subjects who received [ 99m Tc]rBitistatin as part of a Phase I clinical trial. Results: The main organs that accumulated [ 99m Tc]rBitistatin were kidneys, liver and spleen in all animal species and humans. The main organs seen on human images were the kidneys and spleen. Liver uptake was fainter, and soft-tissue background was low. [ 99m Tc]rBitistatin bound to circulating platelets in blood, with a higher percentage of binding to platelets in guinea pigs and dogs compared to that in humans. Plasma protein binding was low and of little consequence in view of platelet binding. The main route of excretion was through the urine. [ 99m Tc]rBitistatin did not affect platelet counts in humans or dogs. Conclusions: [ 99m Tc]rBitistatin, when administered at low doses for imaging, has no adverse effects on platelets and has the qualitative biodistribution predicted by animal studies. [ 99m Tc]rBitistatin was found to bind to circulating platelets in humans, suggesting that it will be able to bind to activated platelets in vivo in patients with acute

  9. Regional differences between {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi [Department of Nuclear Medicine and Radiology, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryomachi Aoba-ku, 980-8575, Sendai (Japan)

    2003-11-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8{+-}6.6 years) were assigned to {sup 99m}Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6{+-}6.7 years) to {sup 99m}Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  10. Preparation and bioevaluation of 99mTc-carbonyl complex of guanine

    International Nuclear Information System (INIS)

    Cigdem Ichedef; Serap Teksoez; Kamile Senocak; Eser Ucar; Ayfer Yurt Kilcar

    2011-01-01

    The aim of this study is to prepare radiolabeled guanine with 99m Tc(CO) 3 + core. For this purpose, guanine has been radiolabeled with 99m Tc(CO) 3 + core. Quality control study of radiolabeled guanine molecule with 99m Tc(CO) 3 + core was performed by thin layer radio chromatography (TLRC) and high performance liquid radio chromatography (HPLRC). The results showed that the radiolabeling yield was quite high (94 ± 3%). Beside that 99m Tc(CO) 3 -Gua complex has showed good in vitro stability during the 24 h period. Radiopharmaceutical potential of this complex was evaluated in Wistar Albino Rats. It was concluded that 99m Tc(CO) 3 -Gua could be used as a nucleotide radiopharmaceutical for in vivo applications. (author)

  11. The stability of 99Tcsup(m)-DTPA in an aerosol delivery system

    International Nuclear Information System (INIS)

    Pearson, D.; Richards, C.B.; Frier, M.

    1986-01-01

    99 Tcsup(m)-DTPA is now widely used in aerosol nebulizers for routine ventilation lung scanning. The stability of a commercially available DTPA kit has been measured when used in an aerosol delivery system and compared with the stability when stored in the parent vial according to the manufacturer's instructions. No significant breakdown was measured up to 8 h after reconstitution in the parent vial and up to 3 h when used as an aerosol. Values of the half time of clearance of DTPA aerosols in a group of 23 patients are compared with values given in the literature. (author)

  12. [{sup 99m}Tc]TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent

    Energy Technology Data Exchange (ETDEWEB)

    Meiping, Kung [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Stevenson, D A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Ploessl, K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Meegalla, S K [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Beckwith, A [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Essman, W D [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); Mu, M [Department of Radiology, University of Pennsylvania, Philadelphia (United States); Lucki, I [Department of Psychiatry, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States); Kung, H F [Department of Radiology, University of Pennsylvania, Philadelphia (United States); [Department of Pharmacology, University of Pennsylvania, Philadelphia (United States)

    1997-04-01

    Technetium-99m is the most commonly used radionuclide in routine nuclear medicine imaging procedures. Development of {sup 99m}Tc-labeled receptor-specific imaging agents for studying the central nervous system is potentially useful for evaluation of brain function in normal and disease states. A novel {sup 99m}Tc-labeled tropane derivative, [{sup 99m}Tc]TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. After i.v. injection into rats, [{sup 99m}Tc]TRODAT-1 displayed specific brain uptake in the rat striatal region (striatum-cerebellum/cerebellum ratio 1.8 at 60 min), where dopamine neurons are concentrated. The specific striatal uptake could be blocked by pretreating rats with a dose of competing dopamine transporter ligand, {beta}-CIT (or RTI-55, i.v., 1 mg/kg). However, the specific striatal uptake of [{sup 99m}Tc]TRODAT-1 was not affected by co-injection of excess free ligand (TRODAT-1, up to 200 {mu}g per rat) or by pretreating the rats with haloperidol (i.v., 1 mg/kg). The specific uptake in striatal regions of rats that had prior 6-hydroxydopamine lesion in the substantia nigra area showed a dramatic reduction. The radioactive material recovered from the rat striatal homogenates at 60 min after i.v. injection of [{sup 99m}Tc]TRODAT-1 showed primarily the original compound (>95%), a good indication of in vivo stability in brain tissue. Similar and comparable organ distribution patterns and brain regional uptakes of [{sup 99m}Tc]TRODAT-1 were obtained for male and female rats. (orig./AJ). With 4 figs., 6 tabs.

  13. {sup 99m}Tc generator preparation using (n, {gamma}){sup 99}Mo produced ex-natural molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Le, So Van [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Theoretical assessment on the chromatographic {sup 99m}Tc generator preparation using (n, {gamma}) {sup 99}Mo produced ex-natural molybdenum was carried out. The relationship between the neutron flux for MoO{sub 3} target activation, Mo-content or Mo adsorption capacity of column packing material, {sup 99m}Tc pertechnetate concentration and/or {sup 99m}Tc radioactivity of eluate was established. The reasonably lower limit of neutron flux of reactor and Molybdenum content of column packing material were found out to estimate the production of portable chromatographic generators available for nuclear medicine application. The concentration of {sup 99m}Tc pertechnetate eluate of low {sup 99m}Tc concentration using the column elution technique was also evaluate theoretically and conducted successfully in practice. Three options of {sup 99m}Tc generator using Titanium-Molybdate, Zirconium-Molybdate and Zirconium Oxide as generator column-packing materials were prepared and successfully put into use in nuclear medicine application. (author)

  14. Preoperative localization of parathyroid carcinoma using Tc-99m MIBI.

    Science.gov (United States)

    Kitapçi, M T; Tastekin, G; Turgut, M; Caner, B; Kars, A; Barista, I; Bekdik, C

    1993-03-01

    A patient with parathyroid cancer is presented who underwent Tc-99m MIBI scintigraphy. The Tc-99m MIBI image demonstrated increased accumulation of activity at the lower pole of the left thyroid lobe which was later confirmed as a parathyroid cancer. Uptake by parathyroid cancer must be kept in mind as a cause of increased Tc-99m MIBI accumulation when a disease is in question in the thyroid or parathyroid gland.

  15. Direct labelling of monomeric antibody fragments Fab' with 99mTc

    International Nuclear Information System (INIS)

    Li Jun; Wang Shizhen; Yang Ziyi

    1994-01-01

    Direct labelling method and conditions of monomeric antibody Fab' with 99m Tc were investigated. Polyclonal antibody IgG was digested with ficin to produce dimeric fragments F(ab') 2 , which was subsequently reduced to monomeric fragments Fab' with 2-mercaptoethylamine. Finally, Fab' was incubated with sodium gluconate (Sn(II)) kit solution and 99m TcO 4 - eluted at room temperature to form 99m Tc-Fab'. The labelling efficiency was 85%-95%. The stability of labelled products was satisfactory and the elimination rate was faster than 99m Tc-IgG

  16. Whole body bone scintigram with sup(99m)Tc-phosphate compounds

    International Nuclear Information System (INIS)

    Oyamada, Hiyoshimaru; Orii, Hirotake; Tabei, Toshio; Ishibashi, Hiroyoshi.

    1975-01-01

    Among the compounds of four different types, which are sup(99m)Tc-polyphosphate suppled by A Company, sup(99m)Tc-pyrophosphate by B Company, and sup(99m)Tc-pyrophosphate of electrolysis method and sup(99m)Tc-diphosphonate by C Company, sup(99m)Tc-diphosphonate showed the most favorable result with a constantly good scintigram quality. The remaining three compounds were found also favorable for clinical application. Besides these are undesirable accumulations, rather low energy of sup(99m)Tc-causes different pictures upon the anterior and the posterior views, and previously irradiated area shows a decreased uptake of these compounds. The usefulness of whole body scintigrams in the detection of metastatic bone tumors was also discussed. There was a definite superiority with this technique over the conventional X-ray study. Especially, in thoracic vertebrae, pelvic bone, and ribs, far many diseased areas were detected on the scintigrams than the areas which the physicians noticed or suspected the metastases. As a conclusion, although there are some problems on the scintigrams, it can be said that sup(99m)Tc-phosphate compounds are very useful in detection of metastatic bone tumors, especially with the help of whole body scanner. (JPN)

  17. The quality of 99mTc-radiopharmaceuticals - a basic requirement in the diagnostic nuclear medicine

    International Nuclear Information System (INIS)

    Ivanova, S.; Popsavova, H.; Kostadinova, I.

    2011-01-01

    Development and application of new high quality radiopharmaceuticals (RP) are of a great significance for the development in nuclear medicine. The high quality of the radiopharmaceuticals has a major influence on the accuracy of nuclear medical examinations. Therefore, a good knowledge and application if various control methods, is essential. Radiochemical impurities affect the quality of RP most significantly and they can appear at every stage of the preparation. The aim of this review is to present the literature information concerning the quality of the most commonly used radiopharmaceuticals, labeled with 99m Tc, and all requirements for them, i.e. radiochemical, radionuclide and chemical purity. This is well-known fact that metastable isotope of Technetium is golden standard for diagnostics in nuclear medicine. Research shows that about 80% of approx. 25 million nuclear medical studies a year are performed with this radionuclide. According to the European Pharmacopoeia and to the leaflets provided with the kits, radiochemical purity must exceed 95%. The main radiochemical impurities in 99m Tc-radiopharmaceuticals are free pertechnetate ( 99m TcO 4 - ), whose presence causes accumulation of RP in the thyroid gland, stomach, gastrointestinal tract, or the salivary glands, leading to a wrong diagnosis, and reduced hydrolyzed technetium, which causes visualization of the reticulo-endothelial system. This paper contains information about the authors' experience with analyses of the radiochemical purity of the two most commonly used radiopharmaceuticals in Bulgaria - for bone and renal scintigraphy (MDA and DTPA). An Instant Thin-Layer Chromatography (ITLC) is used for this purpose. It is concluded that the high quality of the applied 99m Tc-radiopharmaceuticals can be guaranteed only with both selection of renowned manufactures, recognized by EU, and a routine daily control of the labeling and generator eluate, meeting all requirements of the manufacturer and

  18. Renal excretion of /sup 99m/Tc-diphosphonate in osteomalacia

    International Nuclear Information System (INIS)

    Macfarlane, J.D.; Khairi, M.R.A.; Ricciardone, M.; Wellman, H.N.; Johnston, C.C. Jr.

    1979-01-01

    Bone scans were performed on a patient with osteomalacia using /sup 99m/technetium-ethane-1-hydroxy-1,1-diphosphonate (/sup 99m/Tc-EHDP). The renal excretion of /sup 99m/Tc-EHDP was measured and the results were compared with those obtained in 4 patients with idiopathic osteoporosis

  19. Using Tc-Re chemical analogy to synthesize and identify new 99mTc complexes

    International Nuclear Information System (INIS)

    Gambino, D.; Kremer, C.; Cartesio, S.; Leon, A.; Kremer, E.

    1989-01-01

    The strong chemical resemblance between Tc and Re is applied to design and evaluate experiments with 99m Tc complexes. A combination of spectrophotometric and electrophoretic techniques allows to propose the formula [TcO 2 (amine) 2 ] + for compounds prepared by reduction of 99m TcO 4 - with Zn (solid phase) in presence of several (bidentate) amines. (author) 10 refs.; 2 figs.; 4 tabs

  20. Development of 99mTc-DMSA for kidney imaging

    International Nuclear Information System (INIS)

    Shafii Khamis; Nurshuhadah Mohd Yusof

    2006-01-01

    In nuclear medicine studies, 99m Tc-Dimercaptosuccinic acid ( 99m Tc-DMSA) has been shown to be an excellent radiopharmaceutical agent for detecting focal abnormalities of the renal cortex in patients. The agent, however, oxidizes readily and must be used within 30 minutes of preparation. The instability of the radiopharmaceutical renders the kit less economical to use. Several factors affecting the labeling yield such as the kit formulation, stannous and stabilizer content were investigated. The radiochemical determination of the radiolabelled product was analyzed using I TLC-SG system developed in methyl ethyl ketone and the radiolabelled 99m Tc-DMSA biological distributions were carried out in female rats. Stability study of the radiolabelled 99m Tc-DMSA was carried out using ascorbic acid as stabilizer. Comparative study was also carried out on both the prepared kit and those obtained commercially. The DMSA kit was successfully developed and the result obtained was found to be comparable to that of the commercially available kit. (Author)